Louvers Selection[1]

March 23, 2018 | Author: j4leschel | Category: Building Engineering, Nature


Comments



Description

Previous ViewHome Contents Dimensions Performance Specification LOUVERS Contents Page No. General Product Overview Louver Selection and Sizing 'Quick Select' Model Guide EXTRUDED ALUMINUM LOUVERS Standard J Blade 1602J 2" (51) Deep, Architectural 1604J 4" (102) Deep, Architectural 1606J 6" (152) Deep, Architectural 1604JD 4" (102) Deep, Drainable Head 1606JD 6" (152) Deep, Drainable Head Standard K Blade 1602K 2" (51) Deep, Architectural 1604KD 4" (102) Deep, Drainable Head 1606KD 6" (152) Deep, Drainable Head Drainable Blade 1604D 4" (102) Deep 1606D 6" (152) Deep Dual Drainable Blade 1604DD 4" (102) Deep 1606DD 6" (152) Deep Wind Driven Rain Resistant 1605WD 5" (127) Deep, Drainable Blade Adjustable Blade Louvers 1604AD 4" (102) Deep, Drainable Blade 1606AD 6" (152) Deep, Drainable Blade Combination Operable /Drainable Blade 1606CDAF 6" (152) Deep Acoustical Louvers 1612QS 12" (102) Deep, Sightproof Special Shape Stationary Circular and Semicircular Triangular and Trapezoidal 3 6 8 10 11 15 17 20 22 25 28 31 33 36 39 42 44 46 48 50 51 FORMED STEEL LOUVERS Standard J Blade 1704J 4" (102) Deep 1704JD 4" (102) Deep, Drainable Head 1706J 6" (152) Deep 1706JD 6" (152) Deep, Drainable Head Drainable Blade 1704D 4" (102) Deep 1704DHP 4" (102) Deep, High Performance 1706D 6" (152) Deep 1706DHP 6" (152) Deep, High Performance Adjustable Blade 1704AD 4" (102) Deep, Drainable Blade 1706AD 6" (152) Deep, Drainable Blade BRICK VENTS 16BVC 16BVE 16BVF How to Specify/Order 52 54 56 58 60 62 64 65 67 69 4" (102) Deep/Cast Aluminum 4" (102) Deep/Extruded Aluminum 1 1/4" (32) Deep/Flanged Frame 71 72 72 73 Finishes & Color Guide 74 Catalog December 2010. Copyright© by Nailor Industries Inc. All rights reserved. No part of this catalog may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage and retrieval system without permission in writing from Nailor Industries Inc. In this catalog the terms of "Nailor Industries Inc.", "Nailor", "Nailor Industries" or "Nailor International Group" are synonymous and may be interchangeable for context or clarity. Nailor Industries Inc. pursues a policy of continuous product development and we therefore reserve the right to change any of the information in this publication without notice. Contact your Nailor representative to verify current product details. 2 Previous View Home Contents Dimensions Performance Specification LOUVERS GENERAL PRODUC T OVE RVIEW At Nailor Industries, we’ve been manufacturing premium quality air control products for over thirty years. We’ve learned a lot since producing our first device and have incorporated that knowledge into the latest designs and production techniques that are offered today. Designed and engineered to meet the most demanding specifications, Nailor’s 1600 Series Extruded Aluminum Louvers combine architecturally enhancing aesthetics with excellent performance characteristics. Nailor’s 1700 Series Formed Steel Louvers are a competitively priced option for metal buildings and when low first cost is a priority. So go ahead and take advantage of our experience and dedication to quality engineering and customer satisfaction. Features & Benefits of Nailor 1600 Series Louvers: • Nailor offers a wide variety of blade styles to meet mechanical system requirements and architectural design criteria. • Extruded aluminum blades and frames for high durability and quality fit and finish. • Reinforcing bosses run the full length of each blade for superior strength. • Stainless Steel ‘High-Grip’ fasteners: All Nailor louvers are precision assembled using stainless steel concealed fasteners. Optional fully welded construction available. • Low pressure drop characteristics require less fan energy and contribute to efficient system operation. • Drainable Head is standard on many models for maximum protection against water running down the building face. • Integral caulking slots on all frames to help ensure tight and tidy installation. • Vast selection of finishes and colors. AMCA International Member Nailor Industries is an active member of the Air Movement and Control Association International (AMCA) which provides standardized test criteria for air control devices. In addition, AMCA also offers a Certified Ratings Program which provides assurance that cataloged performance ratings are reliable and accurate. Only products whose ratings are based on tests performed in accordance with AMCA recognized test methods at the AMCA Testing Laboratory or an AMCA Accredited Laboratory, and adhere to the Certified Ratings Program criteria, can be licensed to use the Certified Ratings Seal. EXTRUDED ALUMINUM STANDARD J BLADE LOUVERS Nailor Models 1602J, 1604J and 1606J Standard Blade type louvers feature an architecturally appealing continuous straight blade design (often referred to as a J-style blade) with smooth, clean lines that visually compliment any structure’s exterior styling. Available in channel or optional flanged type, the 2" (51), 4" (102) or 6" (152) deep frame installs easily in most common wall configurations. Suitable for use in exhaust and low to medium velocity intake applications, the blade design features a rear water baffle and provides reasonable protection against general weather conditions. The models exhibit low pressure drop characteristics and a high free area. Reinforcing bosses run the full length of each blade for superior strength. Nailor Standard Blade type louvers are engineered to be architecturally appealing as well as mechanically enduring. Models 1604JD and 1606JD feature a drainable head for improved weather protection. Previous View Home Contents Dimensions Performance Specification 3 providing excellent protection against foul weather conditions. All models feature blades reinforced with full length integral bosses for superior strength and provide “no-see-through” protection from the elements. thus preventing it from entering the airstream. Nailor Storm Resistant louvers are designed to endure as well as provide solid weather protection.LOUVERS GENERAL PRODUC T OVERVIEW STANDARD K BLADE LOUVERS Nailor Models 1602K. Available in channel or optional flanged type. Models 1605WD and 1606HR feature blade designs with multiple water baffles and rain gutters that divert collected water down concealed side downspouts and out the sill pan. Suitable for use in exhaust and low to medium velocity intake applications. WIND DRIVEN RAIN RESISTANT LOUVERS Nailor Models 1605WD. the blade design features a rear water baffle plus an additional center rain hook. Available in channel or optional flanged type. Model 1606VR (in development) utilizes vertical blades with central and rear rain baffles that provide the ultimate in protection against wind driven rain. Blades are reinforced with full length integral bosses for superior strength and are engineered to provide minimal resistance at higher airflows. DRAINABLE BLADE LOUVERS Nailor Models 1604D and 1606D Drainable blade and 1606DD Dual Drainable blade louvers combine maximum weather protection at higher airflow rates with good air performance and pleasing aesthetics that compliment any structure’s exterior styling. Blades are reinforced with full length integral bosses for superior strength and are engineered to provide excellent air performance throughout the full airflow range. Suitable for use in exhaust and low to medium velocity intake applications. 4 Previous View Home Contents Dimensions Performance Specification . 1608DD and 1606HR (in development) Wind Driven Rain drainable louvers are designed and tested to provide maximum protection against water penetration in storm conditions. the 2" (51). 4" (102) or 6" (152) deep frame installs easily in most common wall configurations. the drainable blade design utilizes single or double rain gutters dependent on model that divert collected water down concealed side downspouts and out the sill. thus preventing it from entering the airstream. Models 1604KD and 1606KD feature a drainable head design that collects and channels away the water running down the building face. 1604KD and 1606KD K Blade (formerly Storm Resistant) louvers combine excellent weather protection and performance with aesthetics that compliment any architecture. Standard construction features a drainable head design that collects and channels away the water running down the building face. the 4" (102) or 6" (152) deep frame installs easily in most common wall configurations. Collected water is allowed to drain through sill holes and out the sill pan. Model 1606CDFAF provides operable flexibility as well as maximum protection from the elements. Open Structure protection (TAS-201. Closed Structure protection (TAS-201.LOUVERS GENERAL PRODUC T OVERVIEW COMBINATION DRAINABLE / OPERABLE BLADE LOUVERS Nailor Model 1606CDAF Combination Operable/Drainable Blade type louver combines superior weather protection and fixed-blade aesthetics with airflow control including tight shut-off. Nailor hurricane louvers are engineered to offer design flexibility as well as maximum protection. the design features dual drainable fixed blades with double rain gutters that divert collected water down concealed side downspouts and out the sill. Previous View Home Contents Dimensions Performance Specification 5 . Rear operable blades feature PVC blade edge seals for tight shut-off and can be operated manually or with an actuator. HURRICANE LOUVERS (in development) Nailor Hurricane louvers are subjected to stringent testing for water penetration and structural integrity as dictated by the Miami-Dade County Building Code Compliance Office. single drainable blades and is approved for Wet. Model 1606DMD features fixed. TAS-202 and TAS-203). Both models have been tested to withstand static and cyclical design wind loadings of up to 160 psf. and can prevent penetration of both large and small missiles. Blades are reinforced with full length integral bosses for superior strength and the design exhibits low pressure drop characteristics throughout the airflow range. Suitable for use in exhaust and low to medium velocity intake applications. They are designed to withstand the severe winds and rain associated with hurricane type storms common to the area. Model 1606DCMD features operable rear airfoil blades behind a fixed standard blade type louver and is approved for Dry. TAS-202. TAS-203 and TAS-100A). Using the Free Area Chart for the specific louver model chosen. all included within this catalog. the louver size is given. Use the following Application Guide to assist in determining the appropriate louver type for your application: LOUVER TYPE APPLICATION J Blade Clean aesthetics • Reasonable weather protection • Suitable for Continuous Blade construction • For exhaust and low to medium velocity intake applications K Blade Good weather protection • Suitable for Continuous Blade construction • For exhaust and low to medium velocity intake applications Dual Drainable Blade Excellent weather protection • For exhaust and medium to high velocity intake applications • Continuous Blade construction not recommended due to watershedding requirements Wind Driven Rain Resistant (Drainable) Maximum weather protection • For exhaust and higher intake velocities in extreme weather applications • Continuous Blade construction not recommended due to watershedding requirements • Sight-proof design Combination Drainable/ Operable Blade Excellent weather protection • Ideal for airflow control or tight shut-off • For exhaust and low to medium velocity intake applications Hurricane Louvers Maximum weather protection for severe storm applications • Miami-Dade County Approved for static and cyclical design wind loadings up to 160 psf. select a louver size that provides the required Free Area. After determining the relative importance of each variable. 2. DETERMINE REQUIRED LOUVER FREE AREA: Divide given AIRFLOW (cfm) by the selected FREE AREA VELOCITY (fpm) to determine the required louver free area. in the application. select a free air velocity that is below the beginning point of water penetration. Other factors such as pressure drop and amount of water penetration are dependent upon the free area velocity and can be determined by using the respective performance charts provided for each specific louver model. if so desired. as well as large and small missile penetration prevention HOW TO SIZE LOUVERS The prime factor involved in sizing a louver is the velocity of the air through it’s free area. the maximum practical airflow can be determined by working backwards from the free area chart. wall type/depth.LOUVERS SELECTION & SIZING APPLICATION GUIDE Selection of a louver for a specific application is determined by many variables including aesthetic requirements. a louver style and model can be selected by comparing individual design details and performance data. For extra weather protection. The free area is the actual unobstructed area of a louver through which air can travel. 1. 6 Previous View Home Contents Dimensions Performance Specification . If. SELECT FREE AREA VELOCITY: Select optimum free area velocity for the specific application checking Pressure Drop and Water Penetration charts for acceptable performance. SELECT MODEL: Choose the louver model that is best suited for the specific application. 3. water penetration data generally does not need to be considered. pressure loss criteria and water penetration criteria. Use the Application Guide and 'Quick-Select' Model Guide to assist in making a selection. For 'exhaust only ' applications. See sizing examples on next page. g. w.92 (0. w. (42 Pa) 1606CDAF 43% 6. (37 Pa) 1602K 47% 7.g.) 3952 cfm (1865 l/s) 0. w.g.80) 1025 fpm (312 m /min. Given louver size _____ W x _____ H. To minimize water penetration when sizing intake louvers. DETERMINE MAX. (35 Pa) 1706D 50% 8. w. (5 Pa) 1604KD 47% 7. w. w.g.16 in. w. 3.55 (0.15 in.21 in.g.13 in.g.19 in.05 (0.50 (0.76) 970 fpm (296 m /min. airflow.14 in. (80 Pa) 1604AD 44% 7. MODEL FREE AREA % FREE AREA ft. w.16 in.53 (0. w.45) 977 fpm (298 m /min.) 4680 cfm (2208 l/s) 0.g.77) 1029 fpm (314 m /min.g.) 8420 cfm ( 3973 l/s) 0.76) 896 fpm (273 m /min. ft. w.03 (0.) 8366 cfm (3948 l/s) 0. (32 Pa) 1606D 52% 8. w. (40 Pa) 1606JD 48% 8. (30 Pa) 1706DHP 56% 9.) 8065 cfm (3806 l/s) 0.13 in.g.) 7868 cfm (3713 l/s) 0.66) 953 fpm (290 m /min.15 (0. ft.) 6224 cfm (2937 l/s) 0. (40 Pa) 1606DD 50% 7.04 in.) 6699 cfm (3161 l/s) 0. w. (32 Pa) 1604JD 54% 8.13 in.10 in.8 Pa) 1704J 53% 8. check the pressure drop at the determined airflow rate and resulting free area velocity.g. x _____ fpm = _____ cfm max.) 9114 cfm (4301 l/s) 0.82) 977 fpm (298 m /min.) 8236 cfm (3887 l/s) 0. (35 Pa) 1604D 52% 8.g. Free Area.19 in. (40 Pa) 1706J 53% 8.57 (0.29 (0. RECOMMENDED AIRFLOW THROUGH FREE AREA PRESSURE DROP @ MAX.g. 2.g. w.14 in.64) 1142 fpm (348 m /min.75) 991 fpm (302 m /min.70) 401 fpm (122 m /min.76) 1121 fpm (341 m /min./ ft.77) 1012 fpm (308 m /min.01 oz.10 (0.18 in. w. w. (27 Pa) 1706AD 55% 8.02 in. w. w.70) 892 fpm (272 m /min. 2.) 7906 cfm (3731 l/s) 0. select a louver size with at least the required free area: _____ wide x _____ high = _____ sq.79 (0.) 8001 cfm (3776 l/s) 0.80) 722 fpm (220 m /min.g. (29.79) 869 fpm (265 m /min.77) 937 fpm (286 m /min. Using the Free Area Chart for chosen model. ft. w.84) 988 fpm (301 m /min.2 (3 ml /m 2).) 6766 cfm (3193 l/s) 0.g.64 (0.13 in.) 8530 cfm (4025 l/s) 0. RECOMMENDED FREE AREA INTAKE VELOCITY MAX. (52 Pa) 1606AD 51% 8.g. w.g.79) 938 fpm (286 m /min.13 (0.14 (0. (22 Pa) 1606J 51% 8.11 in. (25 Pa) Note: MAXIMUM RECOMMENDED FREE AREA VELOCITY and MAXIMUM RECOMMENDED AIRFLOW THROUGH FREE AREA are determined by point of water penetration at .) 7768 cfm (3666 l/s) 0. AIRFLOW 1.13 (0.2 (m2) MAX.) 9449 cfm (4459 l/s) 0.78) 976 fpm (297 m /min. select a Free Area Velocity that is below the point of beginning water penetration.) 7038 cfm ( 3321 l/s) 0.89 (0.16 in.g.29 (0.) 8941 cfm (4219 l/s) 0. DETERMINE LOUVER SIZE Example B: LOUVER SIZE GIVEN. (47 Pa) 1612QS 30% 4.) 8140 cfm (3841 l/s) 0. Multiply FREE AREA x acceptable FREE AREA VELOCITY to determine maximum airflow: _____ sq.74) 1017 fpm (310 m /min.) 7413 cfm (3498 l/s) 0.g.g. Use the Free Area Chart for chosen model to determine free area. (32 Pa) 1604DD 51% 8. Previous View Home Contents Dimensions Performance Specification 7 . (37 Pa) 1706JD 52% 8. (35 Pa) 1704DHP 53% 8.80) 961 fpm (293 m /min.05 (0.15 in. 'QUICK-SELECT' MODEL GUIDE Data shown is for 48" x 48" (1219 x 1219) louver size. w.12 in. w. (45 Pa) 1605WD 54% 8.53 (0.70) 527 fpm (161 m /min.76) 1000 fpm (305 m /min.32 in. Determine required louver free area by dividing AIRFLOW by acceptable FREE AREA VELOCITY (Use performance charts to assist in selecting Free Area Velocity): _____ cfm ÷ _____ fpm = _____ sq.76) 1029 fpm (314 m /min.16 in. w. w.g. (40 Pa) 1704AD 50% 8.80 (0.12 in.) 8856 cfm (4179 l/s) 0. Free Area.) 7958 cfm (3756 l/s) 0.77) 852 fpm (260 m /min.g. Using the Pressure Drop Chart for chosen model.32 (0. (47 Pa) 1704D 53% 8.11 in.44 (0.g.55 (0.) 3028 cfm (1429 l/s) 0.) 8598 cfm (4057 l/s) 0. w.93 (0. (10 Pa) 1604J 54% 8.14 in.75) 847 fpm (258 m /min. (27 Pa) 1606KD 50% 7. w.) 7661 cfm (3615 l/s) 0. (32 Pa) 1704JD 52% 8.62 (0.LOUVERS SIZING EXAMPLES: Example A: AIRFLOW GIVEN.74) 1193 fpm (364 m /min.g.g.17 in.) 8237 cfm (3887 l/s) 0.26 (0.g. w.51 (0.09 in. w.g. RECOMMENDED AIRFLOW 1602J 47% 7.) 6818 cfm (3217 l/s) 0. 1. BLADE SUPPORT BRACKETS: Concealed type. inside (rear) mount (adds approximately 3/8" [10] to louver depth). WI 1 1/2" (38) DT H– 1/4 " (6 )S TD . MINIMUM SIZE: 8" W x 8" H (203 x 203). ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). MULLIONS: Concealed architectural style allowing continuous line appearance. Type 304 S. with low pressure drop characteristics. Color Anodized: ❑ ANLB Light Bronze. J style. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. MAXIMUM SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). FLANGED FRAME (FL) (OPTIONAL) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. Color: ______________ . ENGINEER: CONTRACTOR: DATE B SERIES 12 . 70 sq. with reinforcing bosses. Integral caulking slot provided. BLADE ANGLE: Fixed at 30 degrees. Undersize 1/2" (12. HEIGHT – 1/4" (6) STD. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). factory installed on rear of louver on maximum 48" (1219) centers. STANDARD CONSTRUCTION: FRAME: 2" (51) deep. ______________ . 2" (51) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame. Suitable for use in exhaust and low to medium velocity intake applications.5) nominal wall thickness. Perimeter Anchor Clips. 1" [25] to overall louver depth). ❑ ANBK Black. 2" (51) Filter Rack. ❑ AN15 Clear Anodized 215-R1. Undersize 3/8" (9.S. Reinforcing bosses run the full length of each blade for superior strength.10 1600 SUPERSEDES DRAWING NO. ❑ ANDB Dark Bronze. Insect Screen.060" (1.7). ft. No Bird Screen.5). Model 1602J. BLADE SPACING: Approximately 2" (51) on centers. .EXTRUDED ALUMINUM STATIONARY LOUVER 2" (51) DEEP • J BLADE • ARCHITECTURAL MODEL: 1602J (1602SB) NOM.5] Undersize standard): ❑ U00 ❑ U38 ❑ U50 Exact Size.5m 2). BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. flattened aluminum bird screen in removable frame.051 (19 x 1.S. 1" (25) Filter Rack. ARCHITECTURAL STYLE CONCEALED MULLION DETAIL SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). Color: ______________ . Larger louvers will require field assembly of smaller sections. FINISH: Mill. reserves the right to change any information concerning product or pricing without notice. Type 304 S. 1602SB-1 9 . NO M. Aluminum Insect Screen. the blade design features a rear water baffle and provides good protection against general weather conditions. BLADES: Type 6063-T5 extruded aluminum. is an architecturally styled 2" (51) deep louver designed with smooth. ❑ ANMB Medium Bronze. (6.03R Nailor Industries Inc. clean lines that visually compliment any structure’s exterior styling. ❑ AN04 Clear Anodized 204-R1. It is ideal for use in thin wall applications or a/c units where a full depth louver cannot be used. Color: ______________ . Previous View Home Contents Dimensions Performance Specification 1602J . Type 6063-T5 extruded aluminum. ❑ PCC Prime Coat.060" (1.5) nominal wall thickness.22 . the 1602J’s thinline design is styled to appease and engineered to perform. Reinforced with 1" x 1" (25 x 25) angle (adds approx. SCREEN: 3/4" x . Welded Construction.3) expanded. incorporating J style blades. Bird Screen. Available with channel or flanged type frame. .1 . 45 1.92 0.45 0.14 1.27 0.29 5.75 0.04 13.14 0.07 1.53 90 2.86 11.30 2.45 17. w.06 42 1.) 3952 cfm (1865 l/s) .09 0.05 (12.04 0.09 24.13 90 2.1 .25 26.10 (24.78 1.22 15.34 27.08 1.80 1.85 0.98 for 48" x 48" (1219 x 1219) Louver Size 84 2.42 6.50 2.71 0.49 1.19 2.36 2.68 1.10 1.91 2.02 1.69 0.41 16.65 7.58 2.17 3.20 36.15 2.10 0.49 0.09 1.29 27.24 1.04 13.46 0.17 3.55 29.91 1.38 27.41 16.19 1.99 11.71 20.2) .00 2.39 1.57 1.13 1. (sq. ENGINEER: CONTRACTOR: DATE B SERIES 12 .10 1600 SUPERSEDES DRAWING NO.34 15.22 26.54 2.67 0.62 2.19 3.39 6.89 0.41 0.89 2.61 1.35 1.33 4.16 2.22 3.08 0.33 1.39 0.23 2.18 2.74 1.01 24.62 2.56 6.62 0.33 0.00 2.09 0.14 1.23 3.46 17.82 0.86 21.25 14.93 0.35 0.67 1.01 oz.64 1.31 5.83 0.74 20.03 0.20 (49.84 0.61 0.60 6.75 0.33 0.66 20.03 2.23 25. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).08 1.47 29.53 29.57 0.16 527 fpm (161 m/min.23 0.53 0.29 16.13 1.13 2.23 2.57 8.6) .21 15.30 0.73 31.30 4.37 60 1.11 13.03 24.12 0.97 12.42 54 1.10 1.86 1.49 0.48 7.87 22.52 66 1.68 72 1.03 0.98 0.42 0.04 1.31 3.86 0.70 32.41 0.33 0.87 36 0.31 0.05 1.57 7.27 4.27 0.13 14.96 1.63 0.5) .85 0.8) 2000 3000 (609.86 0.23 3.49 18.61 0.11 2.62 19.85 1.81 11.53 0.46 17.58 19.02 0.83 1.13 2.g.77 9.02 (5.77 0.22 0.73 0.72 0.56 2.26 0.38 4.32 18 0.24 4.05 0.19 1.13 1.77 11.g.26 4.20 0.20 0.03 13.33 1.6) 47% 7.59 7.01 0.74 9.99 1.37 1.50 24 0.06 1.74 0.39 27.18 3.95 11.37 0.25 37.58 18.72 0.03 0. 1602SB-2 9 .42 0.18 0.75 0. (Pa) I N T A K E 78 1.70 8.51 2.90 0.51 7.59 18.54 0.34 15.84 0.20 3.96 3.20 2.10 0.79 66 1.22 0.70 8.76 1.46 1.64 1.23 25.10 1. reserves the right to change any information concerning product or pricing without notice.83 32.93 23.04 in.54 6.19 2.27 1.42 0.52 18.36 1.18 2.31 15.41 1.99 11.21 1.42 5.51 0.28 0.78 0.48 5.26 2.64 2.13 14.80 0.98 0.47 0.08 0.64 0.86 10.86 1.5) 200 300 (61.48 0./sq.21 14.09 0.60 0.09 1.36 5.01 (2.21 0.23 2.71 8.59 0.47 6.25 2.23 1.06 0.76 0.98 2.16 1.34 4.94 0.84 21.11 1.44 5.78 9.26 0.90 11.21 2.20 12 0.61 60 1.29 1.51 6.82 10.57 0.41 4.51 6.64 0.03 0.41 0.45 120 3.3) .31 16.07 35.52 7. (10 Pa) NOTE: To minimize water penetration when sizing intake louvers.15 2.86 1.47 0.77 0. m.53 1.89 0.10 13.96 11.97 0.10 1.37 2.12 1.64 8.79 9.02 23.42 5.88 2.66 0.29 0.21 0.44 8 0.32 15.51 0.19 0.77 0.20 3.24 2.76 36 0.19 0.98 1.65 0.02 0.47 0.33 0.77 9.91 0.15 0. .0 (248.35 6.97 23.27 1.83 21.58 7.30 0.31 4.30 3. ft.56 18.55 0.56 1. ft.33 5.47 17.09 12.63 1.52 1.51 17.98 0.72 0.40 5.04 1.26 3.89 2.56 8.08 13.96 1.44 5.15 0.36 0.0) .29 96 2.31 0.98 0.) Free Area Velocity at Point of Beginning Water Penetration at .EXTRUDED ALUMINUM STATIONARY LOUVER 2" (51) DEEP • J BLADE • ARCHITECTURAL PERFORMANCE DATA MODEL: 1602J (1602SB) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 8 0.17 .19 2.16 0.28 0.58 0.62 0.85 1.78 2.37 0.20 25.45 1.0) .06 23.9) .39 0.07 1.90 0.70 (174.28 3.20 12 0.64 7.60 19.4) 500 (152.00 1.37 4.59 1.45 0.30 0.27 0.90 33.91 22.04 34.88 33.18 3.51 6.98 12.26 2.42 28.74 1.58 1.07 0.48 0.65 7.75 0.98 34.51 6.28 3.50 1.34 15.19 3.12 0.68 2.46 0.90 102 2.04 0.68 19.77 2.59 7.68 19.4) .62 0.44 0.74 0.48 6.24 0.14 25.17 0.20 2.04 0.74 1.70) Static Pressure Drop in Inches w.52 0.02 0.64 8.58 0.92 0.99 0.26 3.12 1.11 1.90 2.00 0.80 1.15 0.07 0.82 9.25 3.18 3.44 6.47 0.28 2.83 10.16 2.075 lbs/ft 3 .62 18.28 0.61 30 0.15 2.87 1.50 0.42 1.21 0.87 1.72 20.60 8.85 0.15 1.73 3.45 0.87 0.24 3.03 23.84 9.21 2.35 5.40 17.16 13.86 10. (3 ml/sq.92 0.35 PRESSURE DROP AIRFLOW / WATER PENETRATION DATA Free Area % Free Area sq.69 9.30 0.75 21.88 10.36 4.53 6.42 5.44 5.69 9. select a Free Area Velocity that is below the point of beginning water penetration.10 1.51 1.14 2.17 13.19 0.09 1.08 1.46 24 0.04 0.09 0.79 0.28 1.45 6.03 0.69 8.78 0.06 1.65 0.44 1.37 1.27 4.54 0.82 3.11 1.07 1.46 0.21 3.83 78 1.76 0.54 0.44 17.4) .56 30.98 1.19 14.47 5.16 1.75 2.59 0. Previous View Home Contents Dimensions Performance Specification 1602J .60 (149.22 54 1.18 2.50 1.17 14.67 8.09 2.46 5.77 9.05 0.05 13.27 114 2.06 0.30 18 0.05 0.69 0.10 0.39 1.98 84 2.50 (124.90 0.09 12.33 15.38 27.97 0.72 0.30 16.37 4.07 24.23 1.70 0.04 0.92 11.32 1.59 6.86 0.77 1.07 48 1.12 2.05 2.25 2.05 12.30 (74.97 12.37 4.09 108 2.36 0.90 21.93 10.08 0.55 0.80 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).02 11.59 7.74 20.4) 1000 (304.15 1.35 0.39 0.00 2.94 0.60 0.78 1.45 0.31 4.36 0.64 0. test duration) Air Volume at 527 fpm Free Area Velocity Pressure Drop @ 527 fpm 72 1.45 0.04 0.73 10.07 0.92 1.72 31.24 0.11 2.24 48 1.31 2.80 10.64 9.55 1.31 3.71 8.51 0.77 8.18 1.36 16.74 0.47 3.07 0.69 30 0.09 3.02 1.69 0.55 29.03 0.36 42 1.90 10.77 20.04 0.34 1.28 3.68 30.90 11.27 3.68 1. Standard air density @ 0.02 1.31 1.54 8.15 1.15 1.10 1.03R Nailor Industries Inc.33 1.21 14.39 0.81 1.22 3.13 2.43 0.51 18.71 96 2.03 (7.54 0.51 0.22 14.37 0.42 39.79 21.13 2.44 0.00 11.92 10.20 0.05 0.12 1.32 0.40 (99.16 0.95 0. m) (15 min.53 0.0) (91.23 2.33 5.7) INTAKE OR EXHAUST .15 2.49 2.18 1.73 0.75 9.24 3.23 15.10 13.15 25.03 0.50 (0.92 22. Other: ______________ . Bird Screen. MAXIMUM SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). OPTIONAL W x H SIZING (1/4" [6. Type 6063-T5 extruded aluminum. J style. PAC Perimeter Anchor Clips. FINISH: Mill. ❑ ISSS Type 304 S.03) nominal wall thickness.03) nominal wall thickness. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ).5m 2). reserves the right to change any information concerning product or pricing without notice.080" (2. flattened aluminum bird screen in removable frame. the blade design features a rear water baffle and provides good protection against general weather conditions. factory installed on rear of louver on maximum 48" (1219) centers.1 . Reinforcing bosses run the full length of each blade for superior strength. with low pressure drop characteristics and a high free area. ❑ ANDB Dark Bronze. FR2 2" (51) Filter Rack. BLADE SUPPORT BRACKETS: Concealed type. ❑ ANBK Black. Undersize 3/8" (9. ❑ FL Flanged Frame.3) expanded. SCREEN: 3/4" x . HEIGHT – 1/4" (6) STD. ❑ PCC Prime Coat. STANDARD CONSTRUCTION: FRAME: 4" (102) deep. is an architecturally styled 4" (102) deep louver designed with smooth.051 (19 x 1. Larger louvers will require field assembly of smaller sections. Color Anodized: ❑ ANLB Light Bronze. 4" (102) on centers. ❑ AN15 Clear Anodized 215-R1. Color: ______________ . FR1 1" (25) Filter Rack. 1" [25] to overall louver depth). Integral caulking slot provided. Available in channel or flanged type. with reinforcing bosses. Suitable for use in exhaust and low to medium velocity intake applications. Undersize 1/2" (12. NO M. 70 sq.7). Model 1604J. WE ESI Extended Sill. WI DT 1 1/2" (38) H– 1/4 " (6 )S TD . Color: ______________ . BLADE ANGLE: Fixed at 37 degrees. ❑ ISA Aluminum Insect Screen. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Reinforced with 1" x 1" (25 x 25) angle (adds approx. Color: ______________ . BLADES: Type 6063-T5 extruded aluminum.080" (2. inside (rear) mount (adds approximately 3/8" [10] to louver depth).10 1600 SUPERSEDES DRAWING NO. ❑ AN04 Clear Anodized 204-R1. clean lines that visually compliment any structure’s exterior styling. ENGINEER: CONTRACTOR: DATE B SERIES 12 .S. . Previous View Home Contents Dimensions Performance Specification 1604J . Insect Screen. ft.5).5] Undersize standard): ❑ U00 ❑ U38 ❑ U50 Exact Size. MULLIONS: Concealed architectural style allowing continuous line appearance. FLANGED FRAME (FL) (OPTIONAL) Welded Construction. BIRD SCREEN ❑ ANMB Medium Bronze.S. (6. the 4" (102) deep frame installs easily in most common wall configurations. ❑ BSN No Bird Screen. OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. ARCHITECTURAL STYLE CONCEALED MULLION DETAIL SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm).EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • J BLADE • ARCHITECTURAL MODEL: 1604J NOM. 4" (102) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ BSSS Type 304 S. BLADE SPACING: Approx. MINIMUM SIZE: 12" W x 12" H (305 x 305). NEW Nailor Industries Inc. . J style blade type. 42 0.35 4.27 1.89 1.13 3. ft.91 0.09 2.20 37.76 9.93 1.05 23.11 0.19 0.14 2.24 3.16 2.68 20.66 1.80 0.39 0.64 0.10 1.87 0.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • J BLADE • ARCHITECTURAL PERFORMANCE DATA MODEL: 1604J FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 .97 0.5) .35 28.67 0.16 2.80 9.73 0./sq.59 0.52 7.37 60 1.0) (91.42 0.41 0.65 0.45 0.32 1.46 2.13 0.83 9. NEW Nailor Industries Inc.07 2.05 2.43 6.65 2.01 (2.87 3.05 PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size Free Area % Free Area sq.81 0.50 2.89 2.73 2.53 2.18 13.12 2.61 30 .16 AIRFLOW / WATER PENETRATION DATA 66 1.29 1.85 0.24 2.48 29.88 22.) Free Area Velocity at Point of Beginning Water Penetration at .11 0.60 2.04 36 0.22 0.42 7.00 1.29 96 2.34 0. ENGINEER: CONTRACTOR: DATE B SERIES 12 .80) Static Pressure Drop in Inches w.39 3.04 0.91 12.52 0.14 13. (3 ml/sq.44 12 0.67 3.01 1.25 3.37 16.06 1.04 2.86 11.40 0.38 0.70 2.84 1.47 1.31 5.94 12.66 1. (Pa) I N T A K E 84 2.4) 500 (152.89 2.60 19.62 30.34 0.39 6.58 18.73 20.90 10.93 23.71 3.86 0.59 2.7) INTAKE OR EXHAUST .68 9.60 90 2.05 0.09 13.46 0.61 0.34 4.10 13.16 0.09 0.g.90 2.72 0.11 14.73 1.16 14.79 10.07 1.62 7.54 9. m) (15 min.69 8.72 108 2.91 0.76 1.30 0.72 21.47 0.09 in.38 5.62 1.89 22.84 11.46 18.59 24 0.39 5.38 17.27 3.57 9.3) .20 26.88 10.43 2.24 2.07 0.59 0.70 1.46 0.10 (24.25 26.08 25.25 0.08 47.19 0.22 0.28 2.53 1.0) .01 11.37 0.29 4.09 0.2) .27 3.88 44.29 2.96 2.53 0.93 2.13 1.30 2.67 0.84 22.22 0.47 6.78 9.30 0.53 1.05 1.73 0.73 21.94 4.75 9.71 0.63 3.12 0.03 23.15 36.36 6.04 35.31 16.66 8.59 0.52 0.89 0.22 1.70 1.25 37.78 1.02 0.24 1.07 1.34 4.48 5.20 2.68 0.05 (12.47 17.83 32.03 (7.78 1.47 0.20 15.37 1.98 1.14 3.03 0.02 (5.32 4. w.75 8.13 0.79 1.41 0.51 2.95 23.09 14.15 2.71 9.22 54 1.74 10.94 0.51 5.32 3.93 60 1.38 2.70 3.56 3.79 11.35 2.07 24.075 lbs/ft 3 .39 4.91 42 1.69 1.12 1.69 8.93 0.06 1.31 3.23 0.38 72 1.29 3.03 0.16 3.99 11.57 0.21 25.31 16.20 14.59 41.68 0.75 1.27 3.64 0.17 3.28 1.10 2.20 4.28 14.33 0.62 0.15 0.85 1.6) .56 0.67 42.49 6.54 0.21 2.65 20.21 37.99 0.08 12.98 13.62 1.30 (74. Standard air density @ 0.49 6.93 1.27 0.81 1.27 96 2.66 1.25 0.66 0.62 30.64 8.25 1.91 2.37 2.85 21.02 12.40 39.38 28.43 5.66 19.88 12.15 2.55 6.49 3.59 7.62 19. . test duration) Air Volume at 722 fpm Free Area Velocity Pressure Drop @ 722 fpm 78 1.97 0.96 11.0 (248.33 4. select a Free Area Velocity that is below the point of beginning water penetration.05 24.41 1.96 1.51 1.05 1.00 3.98 1.44 0.86 1.56 19. Previous View Home Contents Dimensions Performance Specification 1604J .76 0.83 722 fpm (220 m/min.86 1.54 0.54 6.54 6.89 10.82 32.g.07 48 1.08 25.48 3.29 16.58 0.63 30.25 0.15 15.01 35.60 0.44 0.21 2.36 15.6) 54% 8.27 6.65 7.64 2.91 1.41 17.16 120 3.85 10.17 2.16 1.52 1.73 1.49 8.58 1.34 5.) 6224 cfm (2937 l/s) .28 4.14 2.24 15.59 18.73 20.34 4.19 0.30 18 .33 1.12 1.03 0.50 40.25 4.48 48 1.01 oz.44 2.53 0.22 1.27 3.86 1.40 (99.11 0.12 2.13 0.98 84 2.22 26.66 1.42 28. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).33 38.06 2.62 (0.50 0.46 40.40 1.70 0.25 15.01 1.83 78 1.58 7.38 16.43 0.39 17.72 20.13 2.72 1.41 1.81 0.17 13.79 10.05 0.14 0.71 0.52 0.64 3.91 2.65 9.49 0.60 0.67 8.4) .61 30.45 1.45 0.91 0.03 1.73 0.95 114 2.94 11.88 1.47 5.94 0.12 1.00 1.91 0.08 0.93 34.81 1.36 1.21 4.1 .97 0.69 0.75 10.0) .6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).91 1.65 2. m.68 72 1.77 0.93 0.89 1. ft.49 18.19 0.39 1.43 28.79 3.54 30.81 30 0.48 29.16 2.97 1.85 11.28 0.16 0.37 18 0.74 0.96 23.82 0.32 0.22 26.56 7.64 0.54 17.30 2.00 23.70 8.28 4.71 3.02 13.13 2.93 0.93 1.07 3.79 32.24 14.80 4.57 7.29 2.02 12.70 1.38 4.38 1.41 5.8) 2000 3000 (609.83 0.19 4.76 36 .73 21.61 8.23 2.50 102 2.62 31.79 0.66 0.11 0.33 0.09 1.00 0.19 2.57 18.81 21.42 3.70 (174.13 1.24 26.50 (124.89 10.08 0.77 3.52 66 1.10 2.41 17.76 8.34 0.55 18.12 1.01 12.03 14.70 9.92 10.20 (49.83 2.42 5.20 0.16 0.40 2.95 0. (22 Pa) NOTE: To minimize water penetration when sizing intake louvers.78 32.22 3.79 20.44 6.91 0.22 2.90 2.83 22.85 0.33 27.13 1.78 1.71 54 1.90 22.87 33.9) .09 0.74 2.32 0.86 2. reserves the right to change any information concerning product or pricing without notice.60 (149.29 0.28 0.04 0.65 0.54 0.68 1.5) 200 300 (61.19 2.15 13.13 13.18 25.09 1.71 1.00 12.84 1.43 1.58 1.48 5.57 1.51 8.43 28.21 2.46 24 .48 1.58 7.22 5.52 18.97 34.71 0.19 3.27 3.14 1.26 42 1.35 1.38 0.49 0.86 3.14 0.50 6.13 90 2.45 7.32 28.47 18.25 5.02 0.26 5. (sq.19 0.67 0.09 12.84 9.28 15.83 1.04 24.77 0.29 2.56 7.84 0.43 5.29 15.07 1.4) 1000 (304.05 2.12 1.18 0.27 0.71 31.10 1600 SUPERSEDES DRAWING NO.43 16.53 0.47 3.03 35.40 16.4) .62 8.78 43.33 0. Undersize 3/8" (9. Color Anodized: ❑ ANLB Light Bronze. 70 sq. Larger louvers will require field assembly of smaller sections. . . MAXIMUM SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). BLADE SUPPORT BRACKETS: Concealed type. BLADE ANGLE: Fixed at 37 degrees.080" (2. OPTIONAL W x H SIZING (1/4" [6. 6" (152) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ BSN No Bird Screen. ❑ ISA Aluminum Insect Screen.S.5m 2). Model 1606J. with reinforcing bosses. Available in channel or flanged type. PAC Perimeter Anchor Clips. ARCHITECTURAL STYLE CONCEALED MULLION DETAIL Undersize 1/2" (12. ft. Color: ______________ . Bird Screen. Reinforcing bosses run the full length of each blade for superior strength. WI DT H– 1 1/2" (38) 1/4 " (6 )S TD . M.S. Other: ______________ . ❑ PCC Prime Coat. MINIMUM SIZE: 12" W x 12" H (305 x 305). FINISH: Mill. flattened aluminum bird screen in removable frame. ❑ ANBK Black. SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). with low pressure drop characteristics and a high free area. ENGINEER: CONTRACTOR: DATE B SERIES 12 . Reinforced with 1" x 1" (25 x 25) angle (adds approx. (6. clean lines that visually compliment any structure’s exterior styling.1 . BLADE SPACING: Approximately 6" (152) on centers.10 1600 SUPERSEDES DRAWING NO.03) nominal wall thickness. SCREEN: 3/4" x . Type 6063-T5 extruded aluminum. WE ESI Extended Sill. reserves the right to change any information concerning product or pricing without notice.5] Undersize standard): ❑ U00 ❑ U38 ❑ U50 Exact Size. FR2 2" (51) Filter Rack.03) nominal wall thickness. Suitable for use in exhaust and low to medium velocity intake applications. ❑ FL Flanged Frame. HEIGHT – 1/4" (6) STD. FLANGED FRAME (FL) (OPTIONAL) Welded Construction. the 6" (152) deep frame installs easily in most common wall configurations. factory installed on rear of louver on maximum 48" (1219) centers. J style. Integral caulking slot provided. Color: ______________ . Color: ______________ . ❑ AN04 Clear Anodized 204-R1. BLADES: Type 6063-T5 extruded aluminum. FR1 1" (25) Filter Rack. BIRD SCREEN ❑ ANMB Medium Bronze. OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. NO MULLIONS: Concealed architectural style allowing continuous line appearance. NEW Nailor Industries Inc.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • J BLADE • ARCHITECTURAL MODEL: 1606J NOM. inside (rear) mount (adds approximately 3/8" [10] to louver depth).3) expanded. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). J style blade type.051 (19 x 1. the blade design features a rear water baffle and provides good protection against general weather conditions. ❑ AN15 Clear Anodized 215-R1. Previous View Home Contents Dimensions Performance Specification 1606J .080" (2. is an architecturally styled 6" (152) deep louver designed with smooth. ❑ ISSS Type 304 S.5). ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Insect Screen. 1" [25] to overall louver depth).7). STANDARD CONSTRUCTION: FRAME: 6" (152) deep. BSSS Type 304 S. ❑ ANDB Dark Bronze. 12 0.54 16.52 0.17 0.35 1.40 (99.70 5.30 1.63 23.47 0.28 0.54 12.60 5.87 0.13 0.38 0.4) .46 0.30 0.93 19.72 0.27 4.31 10.29 1.37 4.98 3.15 2.49 3.92 54 2.68 0.53 35.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • J BLADE • ARCHITECTURAL PERFORMANCE DATA MODEL: 1606J FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.87 1.93 22.71 34.53 1.59 1.4) (152.41 16.75 1.12 10.16 5.60 20.g.50 2.96 3.44 1.38 84 3.12 0.93 5.50 25.84 6.05 (12.15 1.16 3.15 0.76) Static Pressure Drop in Inches w.97 20.84 24.97 96 3.25 4. test duration) Air Volume at 1029 fpm Free Area Velocity Pressure Drop @ 1029 fpm 1029 fpm (314 m/min.74 2.12 0.57 6.40 6.72 1.75 8.21 60 2.84 1.46 0.86 0.37 2.88 41.53 33.01 17.29 0.72 0.77 30 1.14 0.48 19.30 (74.46 1.83 16.89 2.44 7.05 12 0.18 2.43 0.74 20.80 0.56 2.37 27.87 8.65 0.) 8366 cfm (3948 l/s) .09 0.43 0.11 0.32 13.50 66 2.42 2.24 16.37 3.20 1.59 0.21 0.73 8.98 1.50 28. (Pa) I N T A K E Free Area % Free Area sq.64 0.14 0.68 0.44 23.62 2.80 1.24 1.27 0.81 3.50 0.65 1.62 2.46 0.10 9.98 7.62 2.88 19.06 0.98 0.34 0.23 2.41 20.81 4. Previous View Home Contents Dimensions Performance Specification 1606J .60 0.71 0.37 0.16 14.52 27.52 1.39 0.33 0.31 0.22 0.05 2.15 0.81 26.01 oz.29 4.77 3.38 9.83 4.56 4.75 1.22 0.75 0./sq.21 1.47 0.56 6.4) 1000 (304.84 15.04 3.05 1. w.21 0.29 2.85 0.32 0.82 0.87 31.99 2.49 23.98 1.9) .93 5.72 16.52 2.25 0.65 4.20 (49.80 72 2.57 0.13 2.04 23.26 0. Standard air density @ 0.26 7.58 0.09 1.00 2.65 1.14 2.52 2.13 24.85 8.38 0.38 18.82 1.10 0.03 1.46 2.21 2.99 25.17 0.00 14.02 1.08 0.10 2.98 2.55 0.54 0.30 0.23 1.61 4.18 3.53 0.91 1.06 3.22 1.76 0.54 42.47 0.97 1.56 0.72 12.38 11.2) .43 1.55 0.0) .13 9.74 2.62 10.80 1.03 0.17 29.54 1.48 21.31 0.53 45.30 14.14 5.37 1.87 2.71 2.95 1.46 15.34 16.87 3.76 0.48 0.32 27.10 1.10 1600 SUPERSEDES DRAWING NO.37 2.96 1.65 1.8) 2000 3000 (609.60 0.72 10.12 5.06 2.45 11.20 0.92 0.04 8.48 0.29 0.43 5.21 0.89 0.46 17.23 0.89 8.61 3.54 3.44 0.31 1.18 5.52 0.87 34.26 2.56 33.21 25.45 0.10 2.04 4.32 1.80 11.95 1.54 37.78 9.71 31.21 3.75 1.62 9.32 0.36 0.59 7.10 (24.94 2.51 11.55 39.43 1.55 36.26 22.48 5.27 14.07 0.93 3.38 2.17 1.20 5.14 11.50 1.25 29.17 0.41 1.18 0.22 18 0.61 17.4) .48 22.33 0.05 1.69 0.77 1.) Free Area Velocity at Point of Beginning Water Penetration at .07 0.36 15.78 2.63 10.31 2.24 11.51 27.81 4. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).11 1.82 0.0) (91.41 0.27 13.08 17. m.64 0.37 0.1 .67 0.21 25.86 2. reserves the right to change any information concerning product or pricing without notice.25 1.50 (124.61 17.g. (sq.49 1.39 14.54 1. ft.09 36 1.93 1.39 42 1.35 2.61 1.04 1.01 30.56 0.15 0.92 27.95 14.81 2.06 13.26 3.86 32.24 1.02 2.67 90 3.35 0.0 (248.38 22.70 10.88 4.65 2.17 13.68 1.69 5.88 1.88 0.57 31.05 0.63 1.68 0.14 2.46 23.11 0.36 1.55 2.07 0.79 2.23 1.13 in.69 16.03 1.84 2.04 28.61 0.07 19.63 48 1.12 2.13 1. select a Free Area Velocity that is below the point of beginning water penetration. m) (15 min.70 18.37 14.19 0.16 2.74 1.59 24.54 11.3) .51 29.28 12.95 2.81 0.78 21.52 1.06 1.84 7.99 7.42 0.65 0.19 8.58 26.13 0.55 38.80 1.32 5.35 17.21 43.94 1.21 5.19 0.38 18.56 2.41 4.54 0.30 8.40 1.53 0.34 3.18 2.30 0.5) 200 300 500 (61.01 2.66 7.26 AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 1.27 0.38 1.09 4.46 0.89 1.20 12.14 1.93 14. ft.75 2.44 9.04 10.52 31.95 1.70 (174.18 1.86 9.26 0.32 1.44 7.32 2.59 8. .58 11. (3 ml/sq.31 14.84 3.09 78 3.61 0.25 2.83 1.25 1. (32 Pa) NOTE: To minimize water penetration when sizing intake louvers.09 2.88 2.87 2.59 0.19 0.15 1.61 0.04 36.28 15.55 1.53 2.98 1.57 3.30 0.04 0.40 0.20 0.34 0.38 1.59 2.76 18.19 29.51 24 0.11 8.19 8.69 0.16 0.74 0.64 16.40 3.36 1.40 3.46 0.75 0.51 2.02 0.21 1.31 7.67 1.76 2.44 0.98 6.01 4.90 3.91 0.75 21.81 3.48 0.73 0.96 6.075 lbs/ft 3 .18 1.17 10.08 5.70 2.02 1.48 0.70 5.94 20.00 2.10 0.89 12.94 9.98 1.07 1.98 10.36 3.19 0.96 3.55 19.47 17.03 (7.81 0.44 2.85 0.12 3.09 0.80 9.00 6.35 8.25 1.19 8.96 13.66 1.62 0.39 0.60 (149.91 13.15 0.76 0.45 1.93 0.14 15.76 0.93 3.11 21.21 38.36 2.68 1.76 0.75 0.07 5.76 1.26 0.22 0.67 1.24 0.64 0.54 29.07 6.23 36.44 6.31 1.90 34.13 (0.04 1.17 21.68 6.38 0.10 1.87 7.47 25.55 17.59 23.35 0.70 2.81 0.37 0.6) .63 11.88 4.77 13.40 11. ENGINEER: CONTRACTOR: DATE B SERIES 12 .09 1.49 1.80 6.7) INTAKE .17 11.37 40.22 12.65 13.33 0.05 1.50 18.30 3.57 30.42 0. NEW Nailor Industries Inc.41 14.99 2.23 0.53 1.83 0.87 21.00 6.33 1.94 3.52 1.04 0.46 13.6)(914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).51 10.29 2.48 0.64 0.6) 51% 8.62 1. clean lines that visually compliment any structure’s exterior styling.051 (19 x 1.080" (2. with reinforcing bosses. Type 304 S. High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). the blade design features a rear water baffle and provides good protection against general weather conditions. ❑ PCC Prime Coat. Larger assemblies require separate visible frames with downspouts. Nailor Industries Inc. Previous View SUPERSEDES DRAWING NO.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • J BLADE • DRAINABLE HEAD MODEL: 1604JD (1604SB) NOM. HEIGHT – 1/4" (6) STD. MINIMUM SIZE: 12" W x 12" H (305 x 305). Suitable for use in exhaust and low to medium velocity intake applications. No Bird Screen.03) nominal wall thickness. . OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. Available in channel or flanged type.5). reserves the right to change any information concerning product or pricing without notice. Color: ______________ . FINISH: Mill. ❑ ANDB Dark Bronze. Color Anodized: ❑ ANLB Light Bronze. 4" (102) MAX. WI DT H– 1/4 " (6 )S TD . 1" [25] to overall louver depth). Welded Construction.22 . ❑ ANBK Black. NO M. Undersize 3/8" (9. Larger louvers will require field assembly of smaller sections. (6. The drainable head feature utilizes a top gutter that collects the water running down the building face and channels it out the concealed downspouts in the side frame. Type 6063-T5 extruded aluminum. Integral caulking slot provided. factory installed on rear of louver on maximum 48" (1219) centers. ❑ ANMB Medium Bronze. ______________ . BLADE SPACING: Approx. MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide. FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 3 Dimensions are in inches (mm). 2011. BLADE ANGLE: Fixed at 37 degrees.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size.5m 2). Model 1604JD is AMCA Licensed and is engineered to be architecturally appealing as well as mechanically enduring. BLADE SUPPORT BRACKETS: Concealed type. BLADES: Type 6063-T5 extruded aluminum. ❑ AN04 Clear Anodized 204-R1. Aluminum Insect Screen.3) expanded. Bird Screen. 2" (51) Filter Rack.03R 1604JD 1604JD February. Type 304 S. Color: ______________ . Model 1604JD. flattened aluminum bird screen in removable frame. Color: ______________ . SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048).S. Reinforcing bosses run the full length of each blade for superior strength. ❑ AN15 Clear Anodized 215-R1. Perimeter Anchor Clips. Insect Screen. Performance Specification . 1" (25) Filter Rack. is an architecturally styled 4" (102) deep louver designed with smooth.S. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). with low pressure drop characteristics and a high free area. . SCREEN: 3/4" x . ENGINEER: CONTRACTOR: DATE B SERIES 2 . thus preventing it from flowing down into the airstream. J style. inside (rear) mount (adds approximately 3/8" [10] to louver depth). Undersize 1/2" (12. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame. ft.7). the 4" (102) deep frame installs easily in most common wall configurations. incorporating J style blades. Reinforced with 1" x 1" (25 x 25) angle (adds approx.11 1600 Home Contents Dimensions 1604SB-1 9 . 4" (102) on centers. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill.2 . 70 sq.03) nominal wall thickness. STANDARD CONSTRUCTION: FRAME: 4" (102) deep.080" (2. 1 1/2" (38) BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. 68 0.66 1.88 10.68 0.13 13.84 0.41 17.59 7.29 0.19 2.05 12 0.43 16.22 0.80 9.64 3.07 48 1.41 38.95 45.29 15.35 28.22 0.53 0.69 8.77 3.72 1.15 13.16 0.47 3.66 1.27 37.03 34.58 1.22 1.07 1.66 8.08 0.84 20.41 5.51 39.75 10.70 1.30 2.47 51.28 14.06 1.24 14.83 2.79 32.07 3.45 0.01 11.71 3.66 3.91 12.91 0.24 2.68 9.39 17.73 21.09 13.15 2.20 36.71 19.40 2.59 108 2.99 Performance Specification .38 0.08 47.08 0.90 2.81 9.21 1.53 1.87 32.20 4.50 0.65 2.08 23.29 78 1.39 6.19 3.12 1.06 23.83 32.10 2.27 6.71 0.56 4.57 7.74 5.41 1.94 12.33 0.76 8.83 22.22 48.13 90 2.51 2.42 102 2.29 96 2.66 0.29 16.88 0.90 10.57 18.16 1.11 0.02 0.33 38.48 5.69 0.19 2.66 0.67 0.33 0.90 22.75 8.70 8.65 20.32 2.38 17. 2011.25 3.52 66 1.09 2.14 SCHEDULE TYPE: PROJECT: 96 2.91 0.98 1.72 42.76 0.26 0.27 0.31 5.18 25.75 24 0.63 30.03 30 0.62 31.70 1.02 13.76 9.29 4.03 1.22 54 1.50 40.05 2.32 4.81 0.43 16.91 1.65 9.38 27.21 2.24 26.58 7.79 11.52 18.74 0.47 0.71 53.64 8.84 22. reserves the right to change any information concerning product or pricing without notice.08 25.50 6.95 0.07 1.05 0.98 13.33 27.12 1.51 1.27 3.62 8.38 28.82 0.27 120 3.50 2.42 28.22 5.05 35.91 0.51 2.25 37.58 18.24 15.88 22.20 2.04 0.61 1.53 1.79 3.97 34.03 14.29 2.16 48.60 2.86 1.93 23.81 21.30 2.99 11.89 1.39 5.58 1.18 13.05 24.16 0.21 4.43 28.54 0.70 3.97 0.52 0.77 0.89 0.69 19.28 4.27 0.74 10.44 6.79 20.27 3.47 17.44 2.02 56.82 32.88 9.46 2.26 5.31 16.58 0.04 12.37 16.32 1.66 19.34 0.28 15.89 2.59 41.49 3.94 11.93 34.10 4.31 3.91 2.16 2.64 0.85 11.11 14.09 0.25 1.37 60 1.73 1.13 1.46 24 .13 2.56 7.32 0.25 0.07 2.29 1.48 3.14 35.23 48.12 1.00 1.14 4.83 1.25 5.20 37.72 4.94 0.05 1.85 0.44 102 2.88 2.16 2.72 54.19 0.36 6.44 0.46 0.81 1.54 0.40 39.47 50.61 0.59 2.60 18.96 1.98 0.52 0.10 13.18 13.00 23.01 1.57 0.71 42.28 0.94 4.91 0.25 3.03 5.61 30 .59 0.04 0.23 2.19 0.52 3.71 3.14 2.29 2.03R 1604JD 1604JD February.36 15.88 12.43 2.27 3.88 1.21 2.16 3.94 22.84 9.35 1.68 1.37 2.75 9.64 7.43 0.39 0.71 1.30 0.60 19.49 6.05 2.09 0.48 17.36 15.57 9.20 0.03 23.12 0.27 3.96 23.05 1.68 41.62 19.13 1.55 4.86 3.14 4.45 1.42 3.38 5.64 2.11 0.38 16.77 2.47 18 0.85 21.67 3.43 6.03 35.84 11.80 0.30 18 .68 72 1.34 0.34 0.21 25.72 0.14 13.86 90 2.25 4.76 1.89 10.34 4.19 0.60 29.31 16.44 0.49 0.52 0.46 0.72 20.42 4.37 1.09 12.55 4.91 1.88 44.24 3.86 0.04 35.35 4.71 9.96 45.44 3.78 32.66 1.32 36 0.58 7.16 14.77 3.48 29.24 2.02 0.87 0.04 2.65 0.76 36 .62 7.93 1.98 1.40 3.59 0.64 0.13 1.48 3.43 1.71 1.24 1.42 7.49 6.37 4.09 2.09 14.29 59.32 3.22 2.81 1.46 40.59 0.07 24.30 0.26 14.33 2.18 0.28 1.22 26.73 1.83 32.01 1.65 7.06 0.86 1.86 11.78 9.48 5.84 1.49 3.80 31.41 17.37 0.22 26.61 8.69 1.06 1.67 3.85 1.82 0.70 114 2.34 4.16 54 1.55 18.60 30.41 0.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO.13 0.56 3.21 3.29 2.28 0.89 22.54 6.59 18.03 0.29 2.35 2.70 2.15 15.87 33.91 0.20 26.54 0.60 0. Nailor Industries Inc.34 5.68 20.85 10.15 1.24 4.88 48 1.78 1.13 0.22 1.07 1.38 2.62 30.48 50.87 3.67 7.14 0.78 1.15 0.62 1.90 2.99 11.83 9.33 1.96 2.45 60 1.21 37.61 30.73 2.86 2.93 10.69 8.39 4.15 2.19 1.71 0.07 0.66 1.00 0.00 12.71 31.12 2.03 0.83 0.91 42 1.73 0.16 24.40 16.14 0.10 2.99 0.17 13.43 28.33 4.60 2.22 3.00 3.21 2.65 2.89 10.46 3.01 12.45 0.49 8.18 1.17 3.75 53.79 10.93 0.40 1.39 3.73 20.25 26.54 17.25 0.04 24.70 0.61 0.41 1.03 0.11 0.96 11.97 0.73 0.19 0.63 4.62 1.02 12.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • J BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1604JD (1604SB) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 .54 6.93 1.38 1.97 0.14 2.52 17.73 66 1.98 84 2.56 7.09 1.08 25.74 2.20 14.51 5.79 20.16 0.73 20.57 0.14 3.52 7.33 26.70 9.56 3.23 0.40 3.47 5.12 2.25 0.63 3.83 78 1.25 15.53 0.93 0.67 0.09 1.57 84 2.32 28.38 0.19 25.85 0.81 0.75 42.47 6.25 14.12 1.27 3.09 0.27 1.35 2.46 18.60 0.08 12.65 0.48 29.32 0.89 1.05 23.94 0.92 10.55 Page 2 of 3 Dimensions are in inches (mm).49 0.79 1.56 19.82 3.73 0.46 39.38 4.67 42.94 3.98 3.45 5.32 26.59 6.19 2.73 21.42 0.53 0.70 1.43 5.12 12.45 7.47 1.80 4.17 2.83 4.91 2.99 45.71 5.25 1.33 0.10 0.10 1.14 1.77 1.93 2. ENGINEER: CONTRACTOR: DATE B SERIES 2 .13 2.19 4.78 1.30 0.98 2.78 43.97 1.40 1.88 1.75 1.72 8.79 0.29 3.77 0.22 .86 1.28 2.09 2.50 40.95 23.67 8.51 1. 1604SB-2 9 .59 4.12 1.11 0.49 18.13 0.93 1.67 3.06 2.60 42 1.14 1.13 3.04 2.01 35.15 36.51 8.67 4.47 0.84 1.70 30.35 4.55 6.93 2.54 30.05 0.04 1.53 2.79 10.54 9.62 30.42 0.72 21.45 27.93 0.74 114 2.41 0.67 0.95 33.56 0.21 47.93 22.27 37.36 1.38 4.64 0.90 120 3. Previous View 108 2.37 2.30 1.54 0.39 50.93 5.56 29.72 0.19 0.2 .34 4.28 4.89 2.71 0.43 5.20 15.02 12.16 2.47 18.42 5.52 1.94 44.40 4.22 0.46 0.43 1.48 1.57 1.40 0.97 56.00 1.01 72 1. (Pa) I N T A K E Free Area % Free Area sq.02 (5.9) .03R 1604JD 1604JD February.6) 961 fpm (293 m/min. .3) .5) .4) .075 lbs/ft 3 .5) 200 300 (61.50 (124.4) . Nailor Industries Inc. (sq.70 (174. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.57 (0. Previous View 2000 3000 (609. reserves the right to change any information concerning product or pricing without notice.4) 500 (152. ft.16 in. 1604SB-2 9 .05 (12. SCHEDULE TYPE: PROJECT: Page 3 of 3 Dimensions are in inches (mm). Nailor Industries Inc.01 (2.0) .30 (74.6) (914) Performance Specification ./sq.40 (99.8) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • J BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1604JD (1604SB) AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 54% 8. m) (15 min. ENGINEER: CONTRACTOR: DATE B SERIES 2 .0) . ft. (3 ml/sq.2 .22 .11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO. test duration) Air Volume at 961 fpm Free Area Velocity Pressure Drop @ 961 fpm 1. m. Seal applies to air performance ratings and water penetration ratings.) Free Area Velocity at Point of Beginning Water Penetration at .2) .g.10 (24.0) (91.20 (49. select a Free Area Velocity that is below the point of beginning water penetration.) 8236 cfm (3887 l/s) .80) Static Pressure Drop in Inches w. certifies the Model 1604JD shown herein is licensed to bear the AMCA Seal. 2011.6) .0 (248. (40 Pa) NOTE: To minimize water penetration when sizing intake louvers.g.4) 1000 (304. w. Standard air density @ 0.7) INTAKE OR EXHAUST .60 (149.03 (7.01 oz. ❑ ANDB Dark Bronze.5m 2 ).EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • J BLADE • DRAINABLE HEAD MODEL: 1606JD (1606SB) NOM.08 1606JD 1606JD February. inside (rear) mount (adds approximately 3/8" [10] to louver depth). WI DT H– 1/4 " (6 )S TD . OPTIONAL W x H SIZING (1/4" [6.11 1600 Home Contents Dimensions 1606SB-1 4 . FINISH: Mill. Color: ______________ . clean lines that visually compliment any structure’s exterior styling. ❑ ❑ ❑ PCC Prime Coat. Color: ______________ . BLADE SUPPORT BRACKETS: Concealed type. . The drainable head feature utilizes a top gutter that collects the water running down the building face and channels it out the concealed downspouts in the side frame. Larger assemblies require separate visible frames with downspouts. ❑ ANBK Black. . Reinforced with 1" x 1" (25 x 25) angle (adds approx. 6" (152) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA Flanged Frame.051 (19 x 1. with low pressure drop characteristics and a high free area. Type 6063-T5 extruded aluminum. Nailor Industries Inc. OPTIONAL FINISHES: ❑ ❑ PC3 Powder Coat AAMA 2603. Previous View SUPERSEDES DRAWING NO.5). BLADE SPACING: Approx.S. MINIMUM SIZE: 12" W x 12" H (305 x 305). ❑ ANMB Medium Bronze.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size. Undersize 3/8" (9. (6. ENGINEER: CONTRACTOR: DATE B SERIES 2 . BLADE ANGLE: Fixed at 37 degrees.S. the 6" (152) deep frame installs easily in most common wall configurations. Suitable for use in exhaust and low to medium velocity intake applications. with reinforcing bosses. Integral caulking slot provided. 1" [25] to overall louver depth). Welded Construction. Undersize 1/2" (12. BIRD SCREEN AN15 Clear Anodized 215-R1. MAX. 1" (25) Filter Rack.080" (2.2 . Color Anodized: ❑ ANLB Light Bronze. the blade design features a rear water baffle and provides good protection against general weather conditions. flattened aluminum bird screen in removable frame.03) nominal wall thickness. NO M. factory installed on rear of louver on maximum 48" (1219) centers. No Bird Screen. thus preventing it from flowing down into the airstream. BLADES: Type 6063-T5 extruded aluminum. 6" (152) on centers. Insect Screen. reserves the right to change any information concerning product or pricing without notice. J style. PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). Model 1606JD is an architecturally styled 6" (152) deep louver designed with smooth. 2" (51) Filter Rack.3) expanded. ISSS WE Type 304 S.7). SCREEN: 3/4" x .080" (2. 70 sq. Bird Screen. ft.28 . Perimeter Anchor Clips. STANDARD CONSTRUCTION: FRAME: 6" (152) deep. HEIGHT – 1/4" (6) STD. Performance Specification . Aluminum Insect Screen. Color: ______________ . Other: ______________ . Reinforcing bosses run the full length of each blade for superior strength. SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 3 Dimensions are in inches (mm). Model 1606JD is engineered to be architecturally appealing as well as mechanically enduring. Available in channel or flanged type. 2011. 1 1/2" (38) AN04 Clear Anodized 204-R1. Type 304 S. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Extended Sill. Larger louvers will require field assembly of smaller sections. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ).03) nominal wall thickness. MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide. 55 1.33 2.75 0.34 16.50 3.36 2.33 14.04 114 4.52 0.61 0.95 1.23 2.39 42 1.2 .80 1.38 22.43 51.39 0.63 1.08 0.14 5.31 0.79 2.04 8.09 0.48 19.05 1.32 2.00 6.02 1.25 1.92 27.41 0.19 0.83 16.87 31.05 1.79 5.85 8.86 9.55 0.29 2.44 7.09 0.26 22.14 2.43 1.80 10.81 4.69 0.77 13.44 3.30 8.07 6.27 4.20 5.65 1.60 0.58 11.52 1.56 33.51 22.94 3.50 0.27 0.99 2.17 11.40 0.17 1.14 37.80 11.38 1.61 1.91 13.19 8.66 7.41 1.15 0.11 21.04 23.00 48.74 108 4.54 11.96 37.22 0.65 SCHEDULE TYPE: PROJECT: Page 2 of 3 Dimensions are in inches (mm).89 22.76 0.38 18.04 1.12 0.37 40.70 2.57 3.31 14.64 43.46 0.46 13.40 11.98 1.49 1.00 2.27 32.13 1.76 51.76 4.07 5.22 0.72 12.36 28.29 0.51 12.34 1.62 2.61 17.92 9.98 2.41 20.33 0.94 9.69 54.73 13.46 0.79 29.37 2.96 6.14 0.46 0.88 15. Nailor Industries Inc.70 5.98 1.56 0.45 11.70 10.59 24.54 3.99 2.35 3.09 2.92 0.83 48.35 8.36 15.11 0.32 13.21 38.50 66 2.68 0.97 1.48 43.30 1.32 0.52 20.90 3.54 1.95 1.00 1.12 3.24 16.92 45.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • J BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1606JD (1606SB) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.47 0.01 4.32 1.07 1.88 1.36 2.03 1.81 2.25 2.59 23.79 3.96 3.65 16.14 0.64 0. Previous View SUPERSEDES DRAWING NO.74 0.88 32.25 1.51 24 0.01 17.56 2.64 0.48 0.63 1.94 1.25 3.46 1.93 1.07 19.18 1.53 1.48 21.53 0.25 4.23 1.49 3.65 13.87 8.18 3.86 0.12 1.92 4.26 3.91 2.30 0.93 0.98 0.72 0.98 3.60 0.48 0.59 0.88 1.78 3.18 5.06 3.26 4.03 0.87 21.24 11.71 0.77 51.27 1.89 1.48 0.62 10.75 1.54 42.88 4.31 7.10 1.84 48.62 1.06 1.13 2.52 1.82 0.28 15.44 6.80 72 2.41 16.54 0.47 0.68 1.19 8.29 4.10 1.70 60.08 27.17 10.12 10.40 1.82 0.45 0.46 38.31 10.61 1.15 8.48 0.25 0.27 14.05 1.23 36.26 2.26 7.02 2.00 14.89 0.29 1.74 1.84 24.67 0.70 18.30 0.54 37.17 3.75 1.05 0.81 3.70 2.10 0.07 5.57 0.22 2.84 6.65 0.68 0.18 2.98 6.97 96 3.53 35.48 0.84 2.61 3.50 4.62 9.71 1.93 5.21 25.38 0.81 3.06 2.61 4.17 13.10 9.65 1.81 4.80 0.53 45.11 8.44 0.85 2.98 10.59 0.00 6.53 1.55 36.15 42.96 13.21 5.63 10.04 1.43 25.62 57.30 19.88 2.58 26.28 0.46 0.40 3.29 3.49 1.79 5.20 0.18 1.51 27.72 40.44 9.95 2.99 7.21 1.51 29.36 3.52 27.48 2.75 1.63 2.40 0.48 22.40 21.88 41.86 32.94 2.87 7.35 2.83 0.87 3.59 8.26 4.82 1.23 0.98 1.87 1.13 24.29 0.16 5.17 0.04 3.04 28.51 10.02 4.49 23.61 0.21 3.04 36.09 78 3.56 4.04 4.19 8.02 1.20 1.93 3.96 3.72 1.63 48 1.67 1.81 0.05 1.15 0.32 1.22 1.75 21.44 1.21 0.09 36 1.77 1.05 2.21 0.58 0.08 1606JD 1606JD February.34 0.55 2.04 0. 2010.57 31.88 4.24 45.64 0.65 2.35 120 5.97 36.52 0.35 1.65 0.52 2.28 12.70 5.24 45.80 1.52 1.31 1.55 38.65 1.64 0.38 1.55 39.78 9.88 0.08 5.76 0.24 1.30 0.69 16.48 25.81 3.47 0.43 17.92 26.80 1.67 90 3.86 35.55 0.11 1.56 6.97 20.16 23.43 0.59 2.90 0.89 2.21 43.09 4.54 16.95 1.09 1.09 2.46 23.43 0.26 102 4.38 0.81 26.63 11.24 0.55 2.74 2.51 11.61 0.10 2.50 2.31 2.85 0.18 2.21 0.76 1.91 1.23 1.38 0.85 0.43 0.17 21.13 9.62 2.42 0.44 7.30 14.64 0.71 34.07 5.46 2.78 21.75 0.39 14.28 .72 3.59 7.57 2.27 13.26 0.37 4.71 2. Performance Specification .13 0.21 25.14 1.48 0.14 11.68 6.06 39.62 0.21 60 2.44 32.64 18.11 0.44 2.99 25.94 20.05 40.59 1.87 2.02 0.03 1.54 12.21 4.94 1.35 17.74 2.07 0.33 0.37 2.04 0.56 0.77 1.01 30.98 1.22 0.64 16.53 3.31 1.81 0.99 3.36 5.19 0.47 17.76 0.53 4.74 2.20 0.93 14.77 30 1.15 0.70 26.27 0.06 3.58 19.17 29.72 0.88 19.05 3.64 3.84 3.61 23.92 54 2.43 5.48 5.74 20.81 0.55 19.20 1.46 15.50 1.22 18 0.57 30.38 84 3.41 4.20 12.13 0.12 12.21 1.70 17.19 29.54 29.50 28.60 20.33 0.68 0.84 15.37 14.55 17.17 0.53 33.10 0.44 23.50 4.24 1.35 0.62 2.20 34.76 2.16 2.26 0.11 1600 Home Contents Dimensions 1606SB-2 4 .50 25.88 7.80 5. ENGINEER: CONTRACTOR: DATE B SERIES 2 .01 2.41 14.74 0.32 0.68 29.27 4.69 5.38 11.19 0.53 0.47 25.05 12 0.32 6.75 8.06 39.76 18.09 1.12 5.20 2.71 31.05 0.15 1.76 0.22 12.15 1.17 0.08 17.15 2.21 2.24 11.32 27.32 5.34 48.67 30.68 1.56 2.10 2.37 3.52 2.49 2.52 31.97 2.38 2.95 14.35 0.40 3.37 1.83 1.29 2.99 42.37 0.53 2.63 23.26 0.30 3.12 2.23 0.52 54.02 4.14 15.34 3.12 0.53 4.11 14.25 1.36 1.21 34.72 1.36 1.45 1.43 51.42 0.33 1.67 1.84 1.34 0.02 2.06 0.54 1.66 1.52 54.61 17.37 1. reserves the right to change any information concerning product or pricing without notice.93 22.28 2.07 0.00 2.38 18.99 4.40 6.08 2.78 4.80 9.46 0.59 0.73 8.04 10.96 1.87 2.75 0.16 14.12 0.86 2.54 0.75 2.69 0.80 6.61 57.73 0.14 2.16 0.42 2.57 6.89 12.16 3.90 34.37 27.37 0.46 17.90 3.87 34.91 0.45 0.19 0.43 1.81 2.38 9.77 3.15 0.78 2.07 0.72 10.45 1.51 2.87 0.76 0.93 3.44 0.18 0.37 0.36 0.06 13.60 7.65 4.24 46.54 1.83 4.60 5.30 0.84 7.50 18.72 16.36 10.29 31.89 8.93 19.98 7.31 0.68 0.25 29.93 5.39 0. Previous View 1000 (304.05 (12. m. ft. select a Free Area Velocity that is below the point of beginning water penetration. reserves the right to change any information concerning product or pricing without notice.6)(914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).5) 200 300 500 (61.4) .6) 1121 fpm (341 m/min.) 9113 cfm (4300 l/s) .6) . Seal applies to air performance ratings and water penetration ratings. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.15 in.8) Performance Specification . ft. w.76) Static Pressure Drop in Inches w. 2011.0) (91. (37 Pa) NOTE: To minimize water penetration when sizing intake louvers.10 (24. .g.50 (124.4) . Nailor Industries Inc. (sq.7) INTAKE . 1606SB-2 4 .01 oz.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO. Nailor Industries Inc. SCHEDULE TYPE: PROJECT: Page 3 of 3 Dimensions are in inches (mm).70 (174. m) (15 min.08 1606JD 1606JD February.4) (152.30 (74.2) . (3 ml/sq.g.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • J BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1606JD (1606SB) AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 51% 8./sq.13 (0. ENGINEER: CONTRACTOR: DATE B SERIES 2 . (Pa) I N T A K E Free Area % Free Area sq. certifies the Model 1606JD shown herein is licensed to bear the AMCA Seal. Standard air density @ 0.60 (149.9) .4) 2000 3000 (609.) Free Area Velocity at Point of Beginning Water Penetration at .0 (248.03 (7.40 (99.2 .28 .0) .20 (49. test duration) Air Volume at 1121 fpm Free Area Velocity Pressure Drop @ 1121 fpm 1.075 lbs/ft 3 .3) . Color: ______________ .5m 2). flattened aluminum bird screen in removable frame. Model 1602K is available with channel or flanged type frame to suit most architectural and mechanical installation requirements. 1602SR-1 9 . 1" (25) Filter Rack.S. Blades are reinforced with full length integral bosses for superior strength and the design exhibits excellent pressure drop characteristics through it’s high free area. ❑ ANMB Medium Bronze. providing good protection against more forbidding weather conditions. 2" (51) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame.3) expanded.1 . MINIMUM SIZE: 8" W x 8" H (203 x 203). FINISH: Mill. ENGINEER: CONTRACTOR: DATE B SERIES 12 .5). EXTRUDED ALUMINUM STATIONARY LOUVER 2" (51) DEEP • K BLADE • ARCHITECTURAL MODEL: 1602K (1602SR) NO M. Previous View Home Contents Dimensions Performance Specification 1602K . Suitable for use in exhaust and low to medium velocity intake applications.5] Undersize standard): ❑ U00 ❑ U38 ❑ U50 Exact Size. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). ______________ . Color Anodized: ❑ ANLB Light Bronze. ❑ AN15 Clear Anodized 215-R1.S. Insect Screen. ❑ ANBK Black.5) nominal wall thickness. . ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Undersize 1/2" (12. ARCHITECTURAL STYLE CONCEALED MULLION DETAIL SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). ❑ PCC Prime Coat. BLADE SUPPORT BRACKETS: Concealed type. STANDARD CONSTRUCTION: FRAME: 2" (51) deep. Reinforced with 1" x 1" (25 x 25) angle (adds approx.10 1600 SUPERSEDES DRAWING NO. SCREEN: 3/4" x .051 (19 x 1. No Bird Screen.5) nominal wall thickness. Color: ______________ . factory installed on rear of louver on maximum 48" (1219) centers.Model 1602K. 1" [25] to overall louver depth). HEIGHT – 1/4" (6) STD. 2" (51) Filter Rack. 70 sq. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. BLADE SPACING: Approximately 2" (51) on centers.22 . MULLIONS: Concealed architectural style allowing continuous line appearance. Larger louvers will require field assembly of smaller sections. Color: ______________ . Welded Construction. Perimeter Anchor Clips. NOM. ❑ AN04 Clear Anodized 204-R1. ❑ ANDB Dark Bronze.7). Integral caulking slot provided. (6. BLADES: Type 6063-T5 extruded aluminum. Aluminum Insect Screen. K style. reserves the right to change any information concerning product or pricing without notice. . inside (rear) mount (adds approximately 3/8" [10] to louver depth). BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. BLADE ANGLE: Fixed at 30 degrees. Type 304 S. which combines good weather protection and performance with aesthetics that compliment any architecture. Bird Screen. incorporating K style blades (formerly "storm resistant" or "stormproof") is a 2" (51) deep louver. Type 6063-T5 extruded aluminum.060" (1. the K blade design features a rear water baffle plus an additional rain hook. ft.03R Nailor Industries Inc. MAXIMUM SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). Undersize 3/8" (9. with reinforcing bosses. FLANGED FRAME (FL) (OPTIONAL) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603.060" (1. It is ideal for use in thin wall applications or a/c units where a full depth louver cannot be used. Type 304 S. WI 1 1/2" (38) DT H– 1/4 " (6 )S TD . 18 1.78 1.00 2.61 19.73 0.03 0.61 1.10 0.33 1.10 1.12 2. (sq.11 2.40 0.75 0.23 15.16 0.03 0.EXTRUDED ALUMINUM STATIONARY LOUVERS 2" (51) DEEP • K BLADE • ARCHITECTURAL PERFORMANCE DATA MODEL: 1602K (1602SR) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 8 0.05 0.29 1.01 oz.59 0.g.03 0.64 2.39 6.65 7.33 0.47 17.30 0.64 0.08 1.15 0.54 6.76 1.59 0.53 6.08 1.72 31.74 9.90 0.5) 200 300 (61.51 0.075 lbs/ft 3 .18 1.5) .47 29.) 3028 cfm (1429 l/s) .31 4. ft.19 2.38 0.25 3.4) 500 (152.10 108 2.4) .72 0.70 9.18 3.55 (0. ft.55 0.21 14.16 0.22 3.06 0.20 12 .90 0.76 0.02 0.18 2.54 0.45 17.59 7. select a Free Area Velocity that is below the point of beginning water penetration.77 21.02 1.74 1.02 (5.15 1.46 24 .42 6.07 35.13 14.83 32.17 401 fpm (122 m/min.45 6.68 72 1.43 0.92 11.50 1.32 16.87 1.75 2.01 (2.43 2.19 0.16 0.91 0.67 1.34 15.51 6.37 60 1.97 12.36 5.30 3.99 0.35 0.17 .27 0.04 0.59 7.30 27.45 1.11 1.71 20.11 13.37 4.75 2.34 15.39 27.31 4.53 1.53 7.05 0.50 2.24 4.86 0.10 1600 SUPERSEDES DRAWING NO.28 3.50 0.55 0.25 48 1.69 0.20 12 0. 1602SR-2 9 .23 0.86 0.66 0.37 0.47 120 3.20 3.66 0.91 1.07 0.68 20.95 0.34 0. ENGINEER: CONTRACTOR: DATE B SERIES 12 .06 23. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).16 13.30 16.80 0.16 1.26 3.47 0.77 9. m.75 20.83 1.08 0.29 96 2.24 2. (Pa) I N T A K E 78 1.54 0.17 14.41 0.36 2.97 0.93 10.35 1.33 0.12 1.32 1.15 2.39 3.35 0.38 27.10 1.90 11.29 114 2.41 3.27 2.65 7.22 3.03 23.09 24.18 3.16 0.17 3.60 (149.97 12.44 8 0.86 1.78 0.07 1.03 13.09 1.38 27.37 2.31 3.51 6.25 37.84 0.89 22.09 0.19 2.84 0.74 1.20 1.77 1.92 0.49 0.24 3.85 0.68 1.78 2.45 0.9) .79 2.54 0.50 (124.46 0.35 1.82 9.89 0.44 28.99 11.77 8.42 5.06 1.26 0.76 36 .27 1.57 8.94 0.42 1.42 2.58 18.59 0.58 0.29 0.48 0.62 19.71 8.35 0.90 0.79 21.87 1.46 1.06 1.70 (174.43 2.29 16.30 0.41 2.36 5.20 36.46 0.19 3.10 1.10 1.08 1.65 7.55 0.77 9.14 14.85 0.50 2.13 2.92 22.89 2.95 3.47 3.03 0.46 5.02 1.66 9.15 1.62 2.33 4.89 0.58 7.55 1.58 1.71 8.24 3.11 0.82 10.86 21.51 6.19 1.22 14.4) 1000 (304.68 19.24 2.41 17.09 0.02 1.88 2.34 27.90 2.65 0.20 0.24 1.07 24.19 0.75 0./sq.72 31.92 10.49 6.37 1.31 15.51 24 0.03 24.84 9.44 18.15 2.12 0.63 1.56 1.44 5.19 3.20 25.59 19.28 3.21 0.13 1.45 0.47 1.36 PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size Free Area % Free Area sq.36 4.80 1.99 84 2.45 0.05 0.56 18.05 13.91 0.23 2.14 2.70 8.88 2.41 0.31 5. (3 ml/sq.44 5.28 4.88 33.48 0.08 1.98 12.62 AIRFLOW / WATER PENETRATION DATA 60 1.14 1.60 7.51 0.49 0.02 0.16 1. w.49 1.51 0.11 1.04 1.36 17.7) EXHAUST INTAKE .21 0.83 2.07 1.25 1.26 2. reserves the right to change any information concerning product or pricing without notice.17 13.30 0.83 78 1.46 1.33 0.37 0.03R Nailor Industries Inc.57 7.14 1.43 54 1.30 (74.10 0.14 25.74 20.44 5.96 11.73 0.74 0.98 1.20 2.70) Static Pressure Drop in Inches w.68 19.35 0.52 0.09 12.15 1.72 0.08 13.79 9.20 14.04 0.39 0.15 2.48 0.69 0.10 13.04 1.98 2.45 1.03 13.6) .60 0.20 3.10 0.52 0.80 0.25 14.03 0.81 1.44 1.39 0.47 1.04 0.61 8.45 7.48 0.79 0.90 21.66 1.45 1.97 0.92 0.02 in.86 11.23 2.28 0.37 4.15 1.10 (24.21 1.21 0.44 1.41 4.12 1.86 1.14 0.28 0.0) (91.03 0.47 0.70 8.10 1.22 0.76 0.52 1.22 2.47 6.53 29.75 10.79 0.10 13.24 0.41 16.90 10.71 0.77 0.94 0.72 0.22 0.44 0.17 3.02 0.03 (7.31 0.11 1.72 0.03 0.87 10.93 23.) Free Area Velocity at Point of Beginning Water Penetration at .11 1.57 1.05 2.82 0.78 9.13 2.57 8.11 2.50 18.27 4.37 0.32 4.06 0.47 17.19 0.1 .16 25.79 9.85 0.98 84 2.g. m) (15 min.23 25.38 4.91 1.41 16.13 2.31 3.69 30 0.29 5.51 17.09 3.54 8.60 0.72 3.92 0.04 34.36 0.26 0.42 0.40 (99.59 7.05 13.28 3.55 29.40 5.05 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).62 0.73 96 2.77 2.97 0.09 1.32 1.83 10.0) .69 0.26 3.86 10.13 1.98 1.62 0.53 0. .05 (12.51 18.56 6.08 0.67 8.21 2.18 2.91 42 1.30 18 .98 0.80 10.73 0.42 5.40 3.79 0.49 0.61 30 .04 0.91 22.56 0.07 48 1.3) .60 0.41 0.24 3.22 26.64 8.83 21.20 0.31 2.48 5.64 0.32 18 0.23 1.47 5.04 0.59 18.28 0.69 9.58 2.26 4.21 14.55 29.16 2. Standard air density @ 0.99 1.85 0.49 2.0) . test duration) Air Volume at 401 fpm Free Area Velocity Pressure Drop @ 401 fpm 72 1.87 0.6) 47% 7.00 2.54 90 2.61 0.42 5.52 66 1.02 23.77 20.8) 2000 3000 (609.02 11.34 5.47 0.05 0.64 8.60 6.88 36 0.66 0.25 26.35 6.96 11.64 1.32 15.35 1.68 1.00 11.14 0.98 0.21 15.07 0.78 1.68 30.39 1.96 1.32 0.62 18.57 0.02 24.19 1.13 90 2.88 10.13 2.84 1.20 (49.80 66 1.82 3.72 32.28 1. Previous View Home Contents Dimensions Performance Specification 1602K .75 0.51 1.31 1.90 11.64 0.13 1.85 1. (5 Pa) NOTE: To minimize water penetration when sizing intake louvers.37 4.16 2.75 0.03 0.0 (248.22 54 1.79 11.48 7.12 0.10 0.34 4.22 0.01 0.25 2.75 9.34 15.42 2.23 2.96 23.51 6.38 3.99 0.61 0.70 0.53 0.12 1.53 0.84 21.20 2.24 0.23 25.42 0.02 0.45 1.72 20.09 12.51 1.28 0.83 11.28 1.28 3.07 0.00 2.34 15.69 8.43 1.4) .51 8.44 1.76 0.41 0.23 15.69 0.20 0.21 2.54 2.99 11.90 33.52 19.65 0.06 12.59 0.59 1.15 0.95 1.06 42 1.47 0.85 1.91 102 2.98 34.59 0.54 0.05 0.07 0.42 39.05 0.2) .58 30.18 2.46 17.91 2.33 5. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Nailor Industries Inc. factory installed on rear of louver on maximum 48" (1219) centers. ❑ ANBK Black. 4" (102) MAX. ENGINEER: CONTRACTOR: DATE B SERIES 2 . (6. Color: ______________ . The design features a drainable head that collects the water running down the building face and channels it out the concealed downspouts in the side frame. FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 3 Dimensions are in inches (mm). Blades are reinforced with full length integral bosses for superior strength and the profile exhibits low pressure drop characteristics throughout the airflow range. Performance Specification . Aluminum Insect Screen. Reinforced with 1" x 1" (25 x 25) angle (adds approx. HEIGHT – 1/4" (6) STD. BLADES: Type 6063-T5 extruded aluminum.S. Color: ______________ . 70 sq. 4" (102) on centers. NO M. inside (rear) mount (adds approximately 3/8" [10] to louver depth). FINISH: Mill. ❑ AN04 Clear Anodized 204-R1.5). Suitable for use in exhaust and low to medium velocity intake applications. Type 304 S. OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. BLADE ANGLE: Fixed at 37 degrees. Undersize 3/8" (9. flattened aluminum bird screen in removable frame.3) expanded. Insect Screen.22 . ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). ______________ . thus preventing it from flowing down into the airstream. MINIMUM SIZE: 12" W x 12" H (305 x 305). . SCREEN: 3/4" x . ❑ PCC Prime Coat. the K blade design features a rear water baffle plus an additional center rain hook. 1" [ 25] to overall louver depth). Previous View SUPERSEDES DRAWING NO. STANDARD CONSTRUCTION: FRAME: 4" (102) deep. ❑ AN15 Clear Anodized 215-R1. Bird Screen.S.7). . Undersize 1/2" (12. ❑ ANDB Dark Bronze.051 (19 x 1. Model 1604KD.080" (2. reserves the right to change any information concerning product or pricing without notice. 4" (102) deep louver. ❑ ANMB Medium Bronze. Welded Construction. Integral caulking slot provided.5m 2). Type 304 S. Perimeter Anchor Clips. Model 1604KD is available with channel or flanged type frame to suit most architectural and mechanical installation requirements and is AMCA Licensed.2 . 2011. WI DT H– 1/4 " (6 )S TD .03) nominal wall thickness. providing good protection against more forbidding weather conditions. MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • K BLADE • DRAINABLE HEAD MODEL: 1604KD (1604SR) NOM. 1 1/2" (38) BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. 2" (51) Filter Rack. ft. BLADE SPACING: Approx. Larger assemblies require separate visible frames with downspouts. combines good weather protection and performance with aesthetics that compliment any architecture. Color Anodized: ❑ ANLB Light Bronze. Type 6063-T5 extruded aluminum. Larger louvers will require field assembly of smaller sections. with reinforcing bosses. K style.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size. 1" (25) Filter Rack. No Bird Screen. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame. BLADE SUPPORT BRACKETS: Concealed type.03) nominal wall thickness.11 1600 Home Contents Dimensions 1604SR-1 9 .03R 1604KD 1604KD February. Color: ______________ .080" (2. 33 0.13 8.86 17.27 42 1.24 43.34 15.96 2.49 30.14 0.05 26.91 0.17 3.07 0.42 9.07 1.43 48.54 1.61 12.28 0.50 12.13 2.56 20.12 11.67 24.54 3.07 11.54 35.50 0.71 29.52 0.01 1.10 5.51 0.80 1.62 7.78 9.57 2.52 1.77 2.98 6.29 2.12 1.74 40.09 1.34 4.88 3.61 36.33 0.46 0.38 14.08 12.34 1.95 1.86 0.07 6.74 19.62 5.62 1.36 14.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • K BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1604KD (1604SR) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.54 1.44 32.31 4.61 9.90 16.63 3.16 18.20 5.98 13.23 3.82 32.36 11.24 1.76 0.80 11.36 0.43 6.59 2.98 30.02 1.36 36.24 1.70 7.62 20.80 1.09 2.62 2.01 1.43 19.90 10.11 13.79 4.51 0.36 0.90 0.22 17.12 3.57 4.39 2.34 0.23 1.35 9.11 2.37 19.43 3.28 1.29 8.85 0.27 0.30 0.06 0.78 2.38 0.59 36.09 0.97 6.19 17.34 0.95 2.02 3.66 5.99 20.18 1.48 1.87 22.69 18.85 1.39 26.77 54 1.19 22.04 32.60 2.24 3.54 7.66 0.66 0.54 48 1.66 11.51 8.77 9.44 0.74 0.56 0.08 1.50 6.42 0.59 0.13 0.81 2.58 0.95 14.57 17.88 2.65 0.23 2.13 0.10 16.03R 1604KD 1604KD February.21 3.47 2.19 0.26 2.23 2.07 17.61 0.97 9.25 3.27 7.85 12.99 4.95 4.05 20.16 8.14 1.93 4.59 3.38 34.93 13.37 1.71 0.76 0.24 0.69 11.92 2.76 0.75 0.75 1.69 2.90 1.59 3.74 1.41 0.73 16.37 8.18 14.56 0.76 24.51 0.10 0.01 2.87 19.35 0.80 3.69 0.40 2.84 1.24 5.35 3.67 1. Nailor Industries Inc.34 9.46 0.83 3. Performance Specification .93 2.27 0.22 1.81 0.56 24.02 60 2.31 12.83 25.94 46.12 18.42 3.92 0.11 2.36 23.32 4.14 1.70 0.07 24.00 36.21 0.46 43.30 2.87 0.68 0.81 SCHEDULE TYPE: PROJECT: Page 2 of 3 Dimensions are in inches (mm).84 9.11 0.2 .61 1.27 43.14 2.36 1.30 4.48 0.06 2.24 1.78 20.58 10.51 24 0.73 0.78 0.04 0.37 1.93 3.73 33.59 30.87 0.05 2.11 1.99 1.07 0.68 10.97 3.13 0.89 2.93 4.61 3.91 0.62 0.38 1.24 12.45 2.04 108 3.22 16.18 11.53 72 2.90 1.31 0.79 0.21 2.61 2.53 5.99 3.76 9.29 1.10 10.56 1.53 27.54 0.83 4.39 0.90 46.00 2.95 1.25 15.81 4.37 2.11 1.79 102 3.57 0.98 2.95 46.39 1.72 22.89 8.92 2.98 2.37 2.94 1.34 17.34 3.60 10.21 0.23 41.66 2.17 51.48 0.60 0.10 8.37 1.55 0.68 23.41 3.25 0.08 0.59 8.40 21.88 0.44 2.15 0.35 0.68 1.17 0.48 7.11 1600 Home Contents Dimensions 1604SR-2 9 .95 3.55 28.52 0.52 14.63 41.76 25.34 0.39 10.61 0.06 22.30 1. Previous View SUPERSEDES DRAWING NO.60 3.00 6.78 1.62 3.96 1.60 0.61 26.48 0.40 20.38 1.16 10.05 0.47 1.29 66 2.53 18.65 1.88 2.46 1.55 4.28 8.66 38.06 5.32 36.75 1.44 0.51 34.83 15.64 4.31 3.48 9.11 2.27 38.46 0.78 0.83 0.06 2.16 0.63 10.97 41.68 1.20 0.05 27.74 33.24 0.17 34.80 12.49 0.02 14.34 13.15 1.77 2.40 34.00 38.55 96 3.85 11.08 4.06 22.39 3.53 5.29 0.41 6.08 3.02 0.72 8.45 7.39 2.61 14.37 19.37 31.07 0.94 2.30 1.46 0.05 12 0.33 18.09 3.17 0.83 1.17 1.59 5.41 1.49 1.30 13.30 0.85 3.04 2.10 7.09 4.19 2.72 0.31 0.22 1.09 0.23 18 0.02 31.60 0.29 14.99 1.60 2.54 20.81 10.19 0.37 1.37 3.45 25.22 1.90 2.15 21.22 0.64 21.25 2.51 2.86 5.38 10.41 0.35 28.70 1.93 17.08 8.46 7.49 1.46 28.12 0.20 1.91 1.92 20.53 7.03 1.56 4.17 0.27 14.17 2.21 11.93 1.75 14.22 4.15 29.14 2.78 1.53 3.71 0.04 84 2.82 1.68 0.19 0.47 0.16 20.58 19.91 17.40 2.69 5.80 78 2.29 0.11 2.46 1.11 1.30 21.27 2.39 8.32 1.66 8.09 1.47 0.74 4.42 11.84 2.35 0.84 7.70 16.45 0.43 0.24 0.15 0.19 0.33 2.43 0.30 1.45 1.62 0.27 2.86 15.94 2.84 18.98 1.36 30.32 0.99 1.38 1.61 6.07 21.11 0.90 3.12 9.46 23.99 13.21 0.13 19.10 1.15 0.31 1.71 1.63 1.01 3.65 2.59 0.48 38.68 0.45 0.83 4.20 1.85 2.68 1.39 0.53 36.16 3.14 24.24 1.47 0.86 2.01 3.66 12.73 2.73 1.37 0.28 7.52 0.85 7.61 15.42 2.82 1.19 32.46 29.59 1.37 4.71 1.02 9.61 1.76 0.40 0.80 3.79 6.05 1.38 0.28 90 3.94 31.44 32.51 1.13 2.22 0.31 6.51 34.92 5.46 0.21 26.80 1.46 2.76 1.02 1.60 0.53 49.57 1.16 6.04 0.59 43.43 0.46 5.89 1.83 0.10 30.15 1.20 0.97 1.01 2.36 0.76 13.08 5.16 1.96 1.30 0.61 2.54 120 4.30 0.41 2.02 1.74 1.02 30 0.61 0.33 2.10 3.62 0.78 0.14 0.74 13.28 2.12 1.52 0.15 0.66 0.18 7.29 0.72 24.22 8.99 25.29 2.41 0.14 1.64 3.28 0.55 2.54 12.09 0.75 0.01 15.03 41.55 0.11 16.23 1.90 14.07 1.43 0.13 23.58 1.56 25.02 36 1.26 0.48 0.68 11.93 22.23 0.82 0.22 3.50 1.30 0.39 7.30 114 4.08 4.86 2.28 14.64 0.15 6.01 12.88 39.15 17.20 1.53 29.77 27.94 19.63 9.49 2.10 7.63 1.61 0.80 16.76 0.03 0.74 2.08 4.50 1.40 1.45 2.83 3.66 0.77 15.73 0.24 0.86 4.89 0.85 4.66 1.48 2.98 0.22 0.19 3.21 3.44 2.60 0.10 1.17 0.55 26.58 0.00 13.84 27.91 3. 2011.07 0.40 22.77 5.92 6.29 28.41 16.12 2.23 10.82 39.82 0.11 27.76 16. reserves the right to change any information concerning product or pricing without notice.07 1.12 0.68 0.15 8.47 10.42 5.59 1.38 24.96 22.77 4.72 0.06 28.70 2.52 1.21 0.88 1.68 5.33 12.63 1. ENGINEER: CONTRACTOR: DATE B SERIES 2 .63 2.17 .38 0. ) 6699 cfm (3161 l/s) .6) (914) Performance Specification . reserves the right to change any information concerning product or pricing without notice.05 (12.17 .5) 200 300 (61. ft. Previous View 2000 3000 (609.6) . ENGINEER: CONTRACTOR: DATE B SERIES 2 .0) (91.40 (99.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • K BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1604KD (1604SR) AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 47% 7.70 (174. (3 ml/sq.075 lbs/ft 3 .11 in.51 (0.30 (74.g.03R 1604KD 1604KD February. 2011. Standard air density @ 0. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.03 (7.5) .11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO. m) (15 min.0) .) Free Area Velocity at Point of Beginning Water Penetration at .4) . Nailor Industries Inc./sq. select a Free Area Velocity that is below the point of beginning water penetration. Nailor Industries Inc. .6) 892 fpm (272 m/min.10 (24. (27 Pa) NOTE: To minimize water penetration when sizing intake louvers. test duration) Air Volume at 892 fpm Free Area Velocity Pressure Drop @ 892 fpm 1.7) INTAKE OR EXHAUST . m.8) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm). SCHEDULE TYPE: PROJECT: Page 3 of 3 Dimensions are in inches (mm). (sq.4) 500 (152. 1604SR-2 9 .0 (248.01 (2.0) .2) . ft.02 (5.4) 1000 (304.50 (124.60 (149.4) . (Pa) I N T A K E Free Area % Free Area sq. Seal applies to air performance ratings and water penetration ratings.9) . certifies the Model 1604KD shown herein is licensed to bear the AMCA Seal. w.70) Static Pressure Drop in Inches w.g.2 .3) .20 (49.01 oz. Welded Construction. BLADE SUPPORT BRACKETS: Concealed type. 1" (25) Filter Rack. Concealed type allowing continuous line appearance up to 120" (3048) wide.22 . with reinforcing bosses. .7). ______________ . SCREEN: 3/4" x . SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). BLADE ANGLE: Fixed at 37 degrees. . High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ).11 1600 Home Contents Dimensions 1606SR-1 9 . BLADES: Type 6063-T5 extruded aluminum.03R 1606KD 1606KD February. Standard construction features a drainable head that collects the water running down the building face and channels it out the concealed downspouts in the side frame. Type 6063-T5 extruded aluminum.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size.3) expanded. HEIGHT – 1/4" (6) STD. ❑ ANBK Black. Performance Specification . SCHEDULE TYPE: PROJECT: ENGINEER: CONTRACTOR: DATE B SERIES 2 . MINIMUM SIZE: 12" W x 12" H (305 x 305). ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. Larger louvers will require field assembly of smaller sections. ❑ PCC Prime Coat. and with a 50% free area. 1 1/2" (38) BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. STANDARD CONSTRUCTION: FRAME: 6" (152) deep. Blades are reinforced with full length integral bosses for superior strength.S.080" (2.03) nominal wall thickness. FLANGED FRAME (FL) (OPTIONAL) Page 1 of 3 Dimensions are in inches (mm). Color: ______________ . the design is engineered to provide good performance throughout the full airflow range. Previous View SUPERSEDES DRAWING NO. Undersize 3/8" (9. Perimeter Anchor Clips. K style. The 6" (152) deep frame is available in either channel or flanged configuration to suit most architectural and mechanical installation requirements. MULLIONS: NO M. Undersize 1/2" (12. 6" (152) MAX. Type 304 S. combines excellent weather protection and performance with aesthetics that compliment any architectural design. the K blade design features a rear water baffle plus an additional center rain hook.S. BLADE SPACING: Approx.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • K BLADE • DRAINABLE HEAD MODEL: 1606KD (1606SR) NOM. WI DT H– 1/4 " (6 )S TD . 2011. No Bird Screen. Larger assemblies require separate visible frames with downspouts. thus preventing it from flowing down into the airstream.5). (6. 2" (51) Filter Rack. flattened aluminum bird screen in removable frame. Color: ______________ . ❑ AN04 Clear Anodized 204-R1. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame. OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. reserves the right to change any information concerning product or pricing without notice. factory installed on rear of louver on maximum 48" (1219) centers. 1" [ 25] to overall louver depth). Insect Screen. ft. ❑ ANDB Dark Bronze. Bird Screen. ❑ AN15 Clear Anodized 215-R1. FINISH: Mill. 6" (152) on centers. Color Anodized: ❑ ANLB Light Bronze. Nailor Industries Inc. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Suitable for use in exhaust and low to medium velocity intake applications. ❑ ANMB Medium Bronze.080" (2.051 (19 x 1. Reinforced with 1" x 1" (25 x 25) angle (adds approx. inside (rear) mount (adds approximately 3/8" [10] to louver depth). providing excellent protection against foul weather conditions. Type 304 S. 70 sq. Model 1606KD. Model 1606KD is AMCA Licensed. 6" (152) deep louver. Aluminum Insect Screen.03) nominal wall thickness.2 .5m 2). Color: ______________ . Integral caulking slot provided. 22 11.93 2.22 0.79 4.33 12.57 1.64 0.72 29.29 0.31 2.76 7.95 6.70 7.51 0.29 1.48 6.15 3.89 38.37 0.51 4.88 38.91 0.21 1.03 4.88 3.13 0.39 26.91 1.69 19.60 0.71 0.50 3.83 1.96 1.72 0.03 4.50 14.31 0.35 2.41 1.70 3.03 2.24 0.68 0.20 23.87 2.89 3.02 5.22 0.84 2.30 3.22 1.78 14. 2011.05 2.41 21.40 0.43 57.66 48.15 0.04 11.71 0.68 1.63 1.44 22.96 1.50 23.64 0.28 1.92 1.29 33.18 0.07 17.68 1.18 15.44 2.10 32.96 2.06 14.50 2.75 114 4.16 3.99 3.13 13.83 1.51 4.10 4.06 1.84 0.49 1.18 60 2.79 5.60 1.31 0.81 21.27 2.06 12.46 0.79 0.91 5.19 0.24 17.57 2.98 10.04 36 1.99 30.40 21.12 1.87 0.87 6.12 29.33 0.27 7.44 0.66 8.50 0.55 6.77 43.65 2.58 3.11 4.44 0.13 24.35 4.62 2.76 30.22 1.41 0.81 2.85 42.61 16.61 2.38 31.35 19.47 2.68 1.92 2.34 0.42 2.29 0.23 0.43 35.55 1.2 .09 14.98 2.97 15.54 30.52 0.01 4.57 0.51 30.94 9.01 28.72 0.99 1.51 2.92 36.05 0.85 6.52 8.47 108 4.67 8.03 8.17 40.32 1.32 42 1.87 6.22 1.74 0.15 10.20 18 0.34 6.12 0.03 27.57 6.24 1.17 15.58 51.08 2.92 35.58 0.29 5.74 45.46 27.75 17.59 1.55 0.74 2.06 3.11 2.21 0.11 3.99 1.52 1.51 1.13 2.56 16.55 3.31 12.49 24 0.70 3.08 6.56 3.40 1.82 5.80 3.30 0.13 1.24 4.91 2.79 5.71 1.72 0.65 3.44 0.11 4.35 3.84 4.05 12 0.09 23.06 2.16 9.88 21.38 4.96 35.82 0.64 3.20 26.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • K BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1606KD (1606SR) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.63 1.58 0.08 23.92 15.35 0.33 0.33 2.74 1.50 1.95 15.77 0.74 0.93 1.43 6.93 1.20 5.99 5.89 27.61 0.12 3.56 5.20 1.73 2.30 0.43 6.42 26.18 1.05 14.96 32.68 48.28 30.37 5.41 0.84 5.26 11.90 3.25 1.16 120 4.78 13.09 28.19 0.95 9.79 0.97 11.93 1.07 1.09 1.97 4.77 17.53 1.78 0.43 3.14 0.54 3.32 40.44 0.30 1.88 9.12 1.14 0.69 2.19 31.45 42.23 23.52 1.12 1.75 7.69 13.72 1.38 4.16 0.06 5.99 7.08 20.72 13.20 2.02 36.63 24.59 19.14 0.37 0.02 11.04 0.04 78 3.57 19.18 0.09 0.27 4.21 1.27 28.65 0.16 0.30 0.43 4.55 25.31 18.32 84 3.82 3.63 1.96 1.35 13.60 25.61 6.61 0.42 13.52 1.68 12.10 2.39 44.11 2.10 0.05 27.51 0.76 9.88 0.10 0.82 0.23 0.27 2.21 47.98 48.45 10.82 6.09 2.46 0.56 3.49 10.04 0.19 2.71 1.95 2.25 0.03 0.21 0.34 11.11 1600 Home Contents Dimensions 1606SR-2 9 .26 17.29 33.73 24.51 2.75 72 2.11 2.49 1.96 2.41 1.18 0.44 0.30 17.88 3.05 24.01 10.08 2.59 0.69 7.24 4.60 51.10 34.46 0.10 21.34 1.10 3.16 0.77 2.92 2.49 1.36 0.61 28.93 39.11 26.78 0.09 13.59 22.66 15.13 1.78 4.06 12.23 4.67 0.21 3.75 11.85 1.33 32.42 11.96 2.55 37.79 1.40 15.58 2.77 1.29 0.80 1.04 2. Nailor Industries Inc.04 1.39 10.09 1.93 8.15 31.10 18.97 2.51 4.09 0.38 0.39 0.07 22.48 2. Performance Specification .00 2.76 3.52 0.26 1.71 2.18 1.65 9.78 10.84 1.05 0.13 14.89 5.82 2.19 0.93 0.99 18.45 0.95 12.13 19.47 66 2.18 2.72 8.17 4.05 1.55 19.07 1.21 1.36 32.99 33.91 7.28 18.07 1.97 2.96 2.15 33.11 0.97 1.42 1.25 7.06 25.37 3.79 4.06 0.77 1.14 0.72 0.64 0.69 2.25 1.37 0.65 1.87 38.90 4.69 28.45 19.91 3.74 1.56 0.54 1.84 22.12 1.82 9.52 0.35 25.49 0.02 29.70 1.30 3.97 4.61 11.41 0.07 2.57 38.34 2.60 4.68 55.35 18.17 .72 0.63 0.26 0.16 27.70 4.70 0.48 0.88 1.37 1.85 25. Previous View SUPERSEDES DRAWING NO.04 1.22 0.57 41.20 13.83 0.31 8.11 0.61 0.54 0.36 1.75 24.80 1.18 0.06 3.92 0.61 0.71 29.04 32.96 1.30 2.25 3.73 2.88 3.30 0.90 13.45 0.38 0.47 1.86 7.42 17.42 35.65 0.63 4.09 12.48 2.03 1.61 48 1.42 2.74 38.41 0.78 1.22 16.38 0.71 0.29 1.46 1.98 0.85 0.76 0.54 12.57 2.07 0.61 7.25 0.54 16.35 0.28 0.41 16.91 3.14 2.24 3.02 6.89 10.55 13.07 0.29 0.99 3.98 1.51 1.37 45.49 20.35 1.19 1.30 1.76 3.47 2.80 1.33 0.63 0.51 1.02 0.02 12.65 26.00 31.39 10.45 0.63 1.80 4.67 0.89 1.33 2.96 35.75 8.10 7.77 43.15 22.11 0.95 1.61 0.34 1.27 6.40 0.53 0.11 16.46 0.82 41.15 1.03 1.23 0.61 90 3.50 18.11 8.06 0.27 2.25 0.46 0.53 10.35 0.59 2.20 16.31 19.18 0.53 2.46 1.99 1.54 10.33 3.17 15.85 52.94 34.30 0.79 0.76 0.07 22.85 0.52 19.75 2.52 7.31 0.58 35.34 2.03 49.18 102 4.77 45.07 0.69 39.45 0.22 45.30 7.67 0.05 6.83 0.37 4.44 1.80 21.07 0.87 26. reserves the right to change any information concerning product or pricing without notice.37 1.14 14.84 7.26 0.09 0.44 9.32 1.01 2.14 0.46 1.25 9.73 0.46 0.77 4.08 17.86 1.75 21.18 4.12 0.75 14.74 0.63 3.59 1.94 1.61 1.15 30 0.39 0.26 0.08 0.51 2.27 23.35 11.59 0.33 SCHEDULE TYPE: PROJECT: Page 2 of 3 Dimensions are in inches (mm).90 2.53 12.14 2.71 0.95 22.33 3.16 3.21 1.70 13.51 9.32 3.35 3.74 19.62 22.17 0.14 12.85 2.18 7.31 2.75 17.22 2.10 3.06 3.90 0.13 0.57 0.39 1.62 0.36 1. ENGINEER: CONTRACTOR: DATE B SERIES 2 .89 54 1.56 0.33 2.43 3.29 2.90 96 3.15 17.51 54.16 40.96 5.04 1.74 3.63 1.97 4.22 1.63 8.86 16.00 10.03R 1606KD 1606KD February.35 20.52 0.65 2.84 3. Seal applies to air performance ratings and water penetration ratings. ENGINEER: CONTRACTOR: DATE B SERIES 2 .17 .40 (99.10 (24.03 (7.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • K BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1606KD (1606SR) AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 50% 7.g.4) 1000 (304.g. w.8) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).6) .0 (248. (3 ml/sq. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.4) .70 (174.20 (49.7) INTAKE .6) 1017 fpm (310 m/min. (Pa) I N T A K E Free Area % Free Area sq.5) 200 300 (61./sq.60 (149. 2011.) Free Area Velocity at Point of Beginning Water Penetration at .0) . Standard air density @ 0.0) .93 (0. SCHEDULE TYPE: PROJECT: Page 3 of 3 Dimensions are in inches (mm).74) Static Pressure Drop in Inches w. (sq. .) 8065 cfm (3806 l/s) . m.30 (74. select a Free Area Velocity that is below the point of beginning water penetration.2 . Nailor Industries Inc.075 lbs/ft 3 .3) . ft.01 (2. test duration) Air Volume at 1017 fpm Free Area Velocity Pressure Drop @ 1017 fpm 1. Previous View 2000 3000 (609. 1606SR-2 9 .2) .50 (124.9) .01 oz.6) (914) Performance Specification . reserves the right to change any information concerning product or pricing without notice.02 (5.4) 500 (152. ft.05 (12.5) .14 in.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO. Nailor Industries Inc. m) (15 min. (35 Pa) NOTE: To minimize water penetration when sizing intake louvers.0) (91.4) . certifies the Model 1606KD shown herein is licensed to bear the AMCA Seal.03R 1606KD 1606KD February. Type 6063-T5 extruded aluminum. BLADES: Type 6063-T5 extruded aluminum. MAX. 1" [ 25] to overall louver depth).03) nominal wall thickness. ft.5). HEIGHT – 1/4" (6) STD.03) nominal wall thickness. BLADE ANGLE: Fixed at 37 degrees.080" (2. OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. BSN No Bird Screen. BLADE SUPPORT BRACKETS: Concealed type. ❑ ANBK Black. Larger louvers will require field assembly of smaller sections. 2" (51) Filter Rack. PAC Perimeter Anchor Clips. FINISH: Mill. STANDARD CONSTRUCTION: FRAME: 4" (102) deep. SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). 2011. Color: ______________ . Bird Screen. flattened aluminum bird screen in removable frame. High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ).S. . (6. ENGINEER: CONTRACTOR: DATE B SERIES 9 . 70 sq. WI DT H– 1/4 " (6 )S TD .051 (19 x 1. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 Extended Sill. ❑ ANMB Medium Bronze.11 1604D 1604D September. Integral downspouts and caulking slot provided. 4" (102) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL Flanged Frame. FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 3 Dimensions are in inches (mm). ❑ PCC Prime Coat.16 . Previous View SUPERSEDES DRAWING NO. Color: ______________ . ❑ ANDB Dark Bronze.080" (2. NO M. the drainable blade design utilizes rain gutters that divert collected water down concealed side downspouts and out the sill. SCREEN: 3/4" x . 1 1/2" (38) BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. Nailor Industries Inc. Larger assemblies require separate visible frames with downspouts. Undersize 1/2" (12.2 . ISA ISSS WE Aluminum Insect Screen. MINIMUM SIZE: 12" W x 12" H (305 x 305). ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). with reinforcing bosses. with good air performance and pleasing aesthetics that compliment any structure’s exterior styling.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • DRAINABLE BLADE MODEL: 1604D (1604SD) NOM. ❑ AN15 Clear Anodized 215-R1. Color: ______________ . Suitable for use in exhaust and low to medium velocity intake applications. Performance Specification .3) expanded. Undersize 3/8" (9. Model 1604D is available with channel or flanged type frame to suit most architectural and mechanical installation requirements and is AMCA Licensed. reserves the right to change any information concerning product or pricing without notice.7). 1" (25) Filter Rack.11 1600 Home Contents Dimensions 2 . inside (rear) mount (adds approximately 3/8" [10] to louver depth). provides excellent weather protection in a 4" (102) deep frame. Drainable blade type louver. factory installed on rear of louver on maximum 48" (1219) centers. Insect Screen. Welded Construction. 4" (102) on centers. BSSS Type 304 S. Reinforced with 1" x 1" (25 x 25) angle (adds approx. . Other: ______________ . Type 304 S. Model 1604D. MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide.5m 2 ).S. Blades are reinforced with full length integral bosses for superior strength and the design provides good air performance through it’s 52% free area as well as maximum protection against the elements. BLADE SPACING: Approx. ❑ AN04 Clear Anodized 204-R1. Color Anodized: ❑ ANLB Light Bronze. 48 11.39 31.61 0.84 0.87 0.85 14.09 2.17 5.09 1.98 1.33 1.12 1.38 0.64 11.05 8.61 2.13 40.51 2.76 45.69 3.13 10.88 1.19 0.48 2.48 15.16 20.13 2.48 0.77 0.99 1.37 84 3.07 1.61 26.22 0.40 51.08 1.02 28.09 29.85 2.45 45.51 4.51 6.84 2.85 38.77 0.29 7.67 2.68 1.76 0.48 29.69 9.57 1.76 0.08 0.70 35.20 1.29 0.58 3.46 0.55 27.45 5.55 3.12 0.33 3.96 4.85 7.07 19.11 3.74 0.88 3.16 2.53 0.14 4.75 114 4.33 45.93 48.53 0.25 1.91 0.41 0.33 1.66 45.53 1.86 24.78 7.22 3.53 3.59 0.38 1.30 25.07 0.99 43.14 53.58 4.33 6.35 0.69 12.95 6.37 2.74 0.35 0.07 1.96 2.86 21.37 1.92 3.16 36 1.66 0.73 0.70 2.91 48.22 1.14 7.60 1.02 33.61 11.40 1.72 5.64 1.66 28.68 2. reserves the right to change any information concerning product or pricing without notice.24 0.57 0.64 20.64 1.58 2.04 5.80 0.70 14.33 32.42 0.89 3.56 23.01 27.44 2.70 2.66 2.30 5.60 0.00 40.26 21.47 0.52 1.67 1.71 2.52 0.38 0.16 9.15 1.15 2.68 0.78 4.35 3.42 0.96 34.89 1.38 36.98 0.52 1.07 13.11 3.20 3.40 10.04 1.93 36.03 35.24 1.71 6.29 2.28 0.47 14.23 2.11 1.31 1.60 10.75 13.24 0.51 4.54 0.85 22.77 33.82 16.18 42.40 0.18 0.10 0.16 0.48 51.50 0.83 23.59 2.44 3.68 0.49 108 4.35 13.04 1.03 0.86 0.95 22.15 8.69 10.62 0.14 23.18 2.24 28.44 1.27 4.24 4.45 0.64 3.02 11.11 1600 Home Contents Dimensions 2 .86 1.09 5.55 33.17 27.31 0.96 26.50 2.21 1.22 0.29 57. Nailor Industries Inc.25 8.11 27.79 15.07 4.98 15.17 0.66 1.12 25.31 0.10 1.29 1.23 11.32 3.98 1.24 7.20 0.48 3.22 31.24 29.88 3.22 0.07 2.47 42.24 21. Previous View SUPERSEDES DRAWING NO.11 6.48 19.30 3.73 1.89 10.83 3.53 40.89 19.50 8.59 0.27 9.34 2.06 0.95 2.44 5.37 0.18 2.25 3.20 1.07 31.14 6.51 0.43 0.87 5.00 2.33 3.94 8.25 0.30 7.60 24 0.02 37.43 21.57 0.49 5.78 1.46 0.20 0.69 0.37 1.20 17.48 1.56 19.42 42 1.53 1.05 14.33 19.44 1.82 3.09 28.38 54.87 1.97 3.91 13.80 1.55 1.76 0.99 2.77 5.73 48 1.55 0.34 16.89 3.93 13.16 3.23 13.15 0.74 14.33 1.80 1.51 1.05 12 0.12 15.13 1.15 42.91 1.98 2.73 3.93 35.81 2.65 19.74 2.67 0.62 36.96 19.30 0.02 11.26 1.19 1.84 1.56 4.94 9.62 7.39 10.68 0.21 28.55 2.45 0.44 40.60 35.09 2.21 2.06 1.18 1.13 1.14 0.82 6.70 0.17 0.23 4.33 0.54 34.57 0.74 7.15 0.51 16.52 0. Performance Specification .58 1.63 0.54 3.49 18.02 1.40 18.93 1.90 2.68 0.55 1.97 1.14 1.13 2.32 0.32 23.26 9.17 2.46 4.48 2.48 13.12 0.37 1.12 31.38 6.43 1.25 0.44 0.93 3.37 2.24 60 2.16 2.60 4.03 4.21 1.90 3.32 9.91 6.81 4.12 2. ENGINEER: CONTRACTOR: DATE B SERIES 9 .87 0.45 0.41 21.13 2.79 2.18 0.93 96 3.62 4.38 0.01 2.34 18 0.94 25.2 .05 9.67 0.34 0.16 21.21 1.49 23.46 1.31 0.74 2.30 2.13 1.12 3.18 2.75 8.55 0.72 7.83 2.16 0.18 19.67 0.34 1.57 7.32 0.93 2.44 26.81 0.27 17.53 12.79 22.18 9.23 8.81 0.10 0.47 0.23 1.23 1.73 30.75 1.42 3.23 1.00 23.85 7.17 0.26 0.48 3.94 1.62 1.84 39.25 0.58 0.71 2.98 5.99 18.29 0.89 9.19 0.13 0.54 0.64 2.04 20.90 0.04 4.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1604D (1604SD) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.85 12.63 22.93 9.75 5.00 2.12 5.78 8.44 12.05 2.29 0.68 1.42 1.20 1.33 2.58 0.62 30.01 120 4.65 1.48 0.05 0.15 3.81 0.33 2.76 3.24 8.78 1.63 0.07 2.53 2.41 5.85 2.84 13.53 51.73 0.57 2.73 3.72 0.13 3.51 0.41 0.18 40.15 24.97 3.83 0.39 0.52 1.48 1.13 27.82 10.32 0.64 0.78 26.95 1.40 10.99 1.38 0.10 6.42 0.11 8.91 3.15 19.33 0.53 1.29 0.36 2.31 33.07 31.68 0.69 2.82 15.52 2.12 0.42 2.50 30 1.37 0.76 10.16 33.46 0.50 7.57 12.81 19.23 0.12 3.27 9.54 6.73 2.76 0.99 1.96 17.68 17.29 0.04 3.65 21.10 6.02 31.06 1.50 0.21 2.78 1.38 1.86 30.52 2.33 0.06 2.50 4.05 0.73 17.78 1.27 4.07 11.70 31.26 0.32 2.99 1.61 1.92 45.96 10.35 0.22 0.10 1.93 22.05 12.24 1.41 1.69 1.55 66 2.06 1.56 9.62 90 3.04 12.74 26.63 1.26 0.34 2.21 15.05 1.64 0.85 3.07 0.88 2.77 0.52 1.18 20.41 8.29 10.23 0.61 0.19 14.80 2.48 3.30 3.64 0.61 0.28 1.77 1.27 0.04 4.08 0.87 1.86 0. 2011.65 13.71 9.49 24.47 1.39 5.05 33.06 3.29 1.37 30.79 5.31 7.70 37.16 .75 0.38 1.42 20.13 14.72 0.68 12.29 2.29 2.97 4.05 0.90 16.11 0.53 38.95 3.70 32.28 15.99 4.11 78 3.90 2.98 2.78 0.52 3.75 42.06 14.46 2.51 0.45 18.06 6.66 13.87 0.00 38.91 0.93 1.57 0.31 10.28 14.80 72 2.35 6.70 1.96 12.95 2.66 48.98 5.27 0.77 6.30 0.09 27.46 0.08 38.44 2.86 21.27 2.41 0.25 17.31 SCHEDULE TYPE: PROJECT: Page 2 of 3 Dimensions are in inches (mm).57 48.25 11.90 1.73 29.53 25.02 3.02 25.85 0.37 1.19 3.03 2.58 5.63 18.07 1.22 11.35 17.84 3.98 54 2.19 102 4.57 16.86 16.47 4.98 2.89 38.29 14.13 0.60 11.92 0.33 2.83 1.39 22.73 43.75 16.37 12.53 18.81 4.20 0.27 4.07 3.84 2.22 24.24 4.59 11.91 6.84 4.26 24.49 0.30 0.74 16.50 4.15 12.79 15.73 17.27 1.33 2.94 16.97 1.11 1604D 1604D September.42 0.33 25. 20 (49.075 lbs/ft 3 .) 7484 cfm (3532 l/s) .6) (914) Performance Specification . Nailor Industries Inc.15 in. 2 . (sq. w. certifies the Model 1604D shown herein is licensed to bear the AMCA Seal.0) ./sq. Seal applies to air performance ratings and water penetration ratings. Nailor Industries Inc.02 (5. m.g. Standard air density @ 0.01 (2.50 (124.4) 1000 (304.0 (248.3) .11 1604D 1604D September.05 (12.5) 200 300 (61. test duration) Air Volume at 906 fpm Free Area Velocity Pressure Drop @ 906 fpm 1.9) . ft.4) .0) .60 (149. 2011.77) Static Pressure Drop in Inches w. SCHEDULE TYPE: PROJECT: Page 3 of 3 Dimensions are in inches (mm). ft.4) 500 (152. m) (15 min.0) (91. (3 ml/sq. Previous View 2000 3000 (609. (Pa) I N T A K E Free Area % Free Area sq.) Free Area Velocity at Point of Beginning Water Penetration at .26 (0.16 .8) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).4) .g.5) .6) 906 fpm (276 m/min.2 .2) .11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO.7) INTAKE .30 (74.40 (99. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.03 (7.01 oz. reserves the right to change any information concerning product or pricing without notice. (37 Pa) NOTE: To minimize water penetration when sizing intake louvers. ENGINEER: CONTRACTOR: DATE B SERIES 9 .6) .70 (174. .10 (24.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1604D (1604SD) AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 52% 8. select a Free Area Velocity that is below the point of beginning water penetration. Color: ______________ .7). ______________ . ❑ PCC Prime Coat.03) nominal wall thickness. ❑ ANDB Dark Bronze.1 . 1606SD-1 6 . 6" (152) on centers. No Bird Screen.5m 2 ). Type 304 S. BLADES: Type 6063-T5 extruded aluminum.25 . 1" (25) Filter Rack. FINISH: Mill. factory installed on rear of louver on maximum 48" (1219) centers.10 1600 SUPERSEDES DRAWING NO. Color Anodized: ❑ ANLB Light Bronze.3) expanded. FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm).03) nominal wall thickness. Larger louvers will require field assembly of smaller sections. ❑ ANBK Black. Previous View Home Contents Dimensions Performance Specification 1606D . Bird Screen. Type 304 S. STANDARD CONSTRUCTION: FRAME: 6" (152) deep. Color: ______________ . Welded Construction.S. Blades are reinforced with full length integral bosses for superior strength and the design. BLADE SUPPORT BRACKETS: Concealed type. SCREEN: 3/4" x . High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). . Undersize 1/2" (12. Color: ______________ . 1/4 " (6 )S TD . Larger assemblies require separate visible frames with downspouts.08 Nailor Industries Inc. the drainable blade design utilizes rain gutters that divert collected water down concealed side downspouts and out the sill. Model 1606D is available with channel or flanged type frame to suit most architectural and mechanical installation requirements. BLADE SPACING: Approx. ❑ AN15 Clear Anodized 215-R1. 1 1/2" (38) BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. ENGINEER: CONTRACTOR: DATE B SERIES 12 . MINIMUM SIZE: 12" W x 12" H (305 x 305).S. 2" (51) Filter Rack. exhibits low pressure drop characteristics throughout the full airflow range. with reinforcing bosses. SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). (6. Aluminum Insect Screen.080" (2. ❑ AN04 Clear Anodized 204-R1. Type 6063-T5 extruded aluminum.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • DRAINABLE BLADE MODEL: 1606D (1606SD) NOM. WI DT H– MAX. BLADE ANGLE: Fixed at 37 degrees. Suitable for use in exhaust and low to medium velocity intake applications. ❑ ANMB Medium Bronze. . ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. Perimeter Anchor Clips. Model 1606D is a drainable blade type louver that provides excellent weather protection. NO M. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Reinforced with 1" x 1" (25 x 25) angle (adds approx. flattened aluminum bird screen in removable frame.5). inside (rear) mount (adds approximately 3/8" [10] to louver depth). reserves the right to change any information concerning product or pricing without notice. with a free area of 52%. HEIGHT – 1/4" (6) STD. OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. Undersize 3/8" (9. 1" [ 25] to overall louver depth). MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide. good air performance and aesthetics that compliment any building design. 70 sq. Insect Screen. Integral downspouts and caulking slot provided. 6" (152) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame.080" (2.051 (19 x 1. ft.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size. 77 15.21 23.15 0.47 0.64 13.66 37.07 0.73 14.g. (32 Pa) NOTE: To minimize water penetration when sizing intake louvers.10 (24.94 3.17 0.71 13.99 28.99 3. (sq.38 35.36 1.47 4.37 0.95 9.92 13.15 0.57 1.20 (49.30 0.34 0.44 3.76 12.18 12.35 0.62 5.18 0.24 14.19 0.32 0.88 16.41 0.89 0.4) 1000 (304.99 29.38 1.28 1.90 3.98 12.29 36.87 19.25 .13 2.67 0.59 1.67 1.16 20.00 2.8) 2000 3000 (609.16 2.03 2.69 1.24 0.56 10.20 0.35 0.39 40.04 4.15 1.73 44.33 0.90 12.98 0.10 4.19 2.25 24.88 25.41 27.27 26.44 2.94 7.62 2.66 0.41 0.67 2. test duration) Air Volume at 1012 fpm Free Area Velocity Pressure Drop @ 1012 fpm 1012 fpm (308 m/min.65 0. Previous View Home Contents Dimensions Performance Specification 1606D .75 2.77 15.12 1.01 1.74 11. Standard air density @ 0.13 1.98 2.26 1.98 28.47 1.04 0.97 1.30 0.01 (2.25 0.69 0.65 2.5) 200 300 (61.58 1.05 (12.24 34.11 13.0 (248.20 1.15 78 3.53 8.75 16.85 17.02 0.07 1.01 1.86 12.11 6.22 5.08 39.86 10.86 14.70 (174.85 0.30 20.48 0.56 2.30 0.42 2.075 lbs/ft 3 .28 0.87 2.06 2.0) (91.43 0.38 1.32 2.99 8.28 1.67 2.44 5.61 0.38 3.53 1.69 5.81 11. ENGINEER: CONTRACTOR: DATE B SERIES 12 .49 0.89 17.07 23.46 0.01 2.80 2.59 1.04 1.57 3.48 0.45 15.52 0.26 2.22 0. ft.51 5.27 0.44 0.88 1.99 1.29 1.28 60 2.7) INTAKE .43 0.77 4.18 0.17 2.1 .48 1.83 0.24 3.25 1.06 1.46 1.43 5.73 5.55 0.59 0.53 16.21 2.66 8.62 25. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).51 2.40 3.68 18.71 0.5) .68 1.68 0.44 2.35 1.76 90 3.4) .44 0.50 33.30 5.03 26.94 1.19 13.41 12.61 6.14 16. 1606SD-2 6 .38 4.59 20.76 0.48 0.56 0.93 2.78 11.52 2.26 8.59 4.49 3.23 1.59 29.12 20.04 19.11 0.15 1.16 0.78 1.00 1.15 0.73 8.03 1.19 2.20 18 0.54 1.27 0.56 0.29 2.61 0.41 0.39 0.96 3.76 0.40 0.94 2.92 21.) Free Area Velocity at Point of Beginning Water Penetration at .32 0.46 2.15 0.78 3.60 12.67 23.82 8.66 3.18 1.14 5.20 1.38 20.70 4.71 0.20 30.32 0.19 3.13 30.10 0.76 0.66 1.29 0.91 6.4) .70 0.41 2.83 26.40 0.59 66 2.21 0.28 5.19 0.83 0.10 3.86 1.69 17.61 2.55 1.11 36 1.81 12.05 2./sq.00 3.31 0.38 1.92 4. m.12 0.37 0.63 0.07 0.47 0.94 1.17 5.48 11.43 32.06 96 4.24 6.47 1.35 16.38 0.12 2.48 1.65 6.87 0.56 0.24 1.49 0.08 28.17 0.36 9.85 2.98 54 2.78 0.09 0.87 7.73 15.g.32 7.10 2.79 6.96 13.36 0.00 5.35 14.72 0.05 1.56 12.70 1.50 0.03 0.86 1.01 oz.13 in.60 2.07 1.44 9.09 1.96 18.63 11.91 1.50 24 0.73 29.77 0.64 0.54 23.91 1.32 0.75 7.15 1.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1606D (1606SD) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.97 24.11 0. w.90 1.13 2.50 (124. (3 ml/sq.43 0.84 2.08 23.12 8.38 8.11 1.88 1.74 1.0) .38 7.87 2.04 2.82 1.09 46.04 0.0) .64 1.96 16.81 1.65 14.96 25. (Pa) I N T A K E Free Area % Free Area sq.22 3.32 9.82 17.60 0.32 21.04 26.87 3.44 0.89 72 2.83 2.74 2.94 1.34 38.57 1.41 1.66 11.84 23.09 18.99 1.70 1.39 1.82 1.20 1.72 0.37 1.59 2.88 3.38 0.10 0.59 1.28 1.18 32.12 0.05 2.30 (74.91 0.06 0.2) .23 10.11 19.95 32.80 15.28 1.03 1.08 2.33 24.80 1.88 2.77 0.47 0.73 48 1.45 84 3.45 27.4) 500 (152.81 18.84 0.55 17.13 0.24 8.21 9.08 6.88 4.08 Nailor Industries Inc.08 9.09 9.05 0.40 0.75 0.73 0.02 (5.01 8.84 0.58 1.07 9.32 (0.30 0.07 0.59 0.35 1.72 14.29 1.56 7.22 0.45 12.55 3.02 39.48 10.10 1600 SUPERSEDES DRAWING NO.62 0.25 0.23 0.05 6.00 1.83 22.38 6.57 0.08 0.40 (99.75 0.50 4.46 0.59 0.67 14.54 0.51 0.22 3.37 8.62 0.31 9.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).30 34.94 4.93 18.55 25.00 30 1.60 (149.86 7.43 1.52 0.76 0.37 1.65 3.51 20.09 21.17 10.83 1.69 0.31 13.31 2.31 AIRFLOW / WATER PENETRATION DATA PRESSURE DROP 1. .68 1.52 0.19 22.91 2.83 5.80 1.13 3.66 0.64 2.87 5.35 2.75 2.61 31. m) (15 min.60 15.27 0.55 0.75 1. ft.14 1.02 10.14 33.13 0.63 18.42 42 1. reserves the right to change any information concerning product or pricing without notice.57 1.57 31.17 1.84 2.39 2.42 18.22 0.52 1.51 15.20 21.71 1.20 0.15 0.06 1.72 1.86 37.83 0.65 4.04 11.03 3.51 43.02 2.36 0.91 2.86 4.07 0.44 2.17 0.28 1.77 0.78 0.12 0.17 1.34 8.93 3.61 9.13 7.08 4.3) .27 8.29 0.09 0.81 15.03 6.12 0.12 21.40 20.16 7.15 10.99 3.61 2.53 13.52 7.37 0.) 8420 cfm (3973 l/s) .61 0.45 2.27 37.30 41.50 6.84 27.80 2.69 1.88 10.29 4.76 25.98 6.22 1.97 1.58 2.23 27.20 0.27 0.23 2.47 1.80 22.52 22.9) .32 4.92 0.6) for 48" x 48" (1219 x 1219) Louver Size 52% 8.34 2.27 0.89 1.33 2.34 19.42 3.64 34.83 3.02 1.29 0.45 0.09 11.6) .44 3.20 5.14 0.77) Static Pressure Drop in Inches w.85 4.71 30.42 32.23 2.05 12 0.97 19.28 1.13 1.73 2.07 1.09 13.37 41.40 0.61 10.40 10.67 0.40 2.28 3.55 1. select a Free Area Velocity that is below the point of beginning water penetration.03 (7. Larger assemblies require separate visible frames with downspouts. Welded Construction. ❑ AN15 Clear Anodized 215-R1. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame. Performance Specification . OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. Model 1604DD is available with channel or flanged type frame to suit most architectural and mechanical installation requirements and is AMCA Licensed. BLADE SUPPORT BRACKETS: Concealed type.3) expanded.11 1600 Home Contents Dimensions 9 . the dual drainable blade design utilizes double rain gutters that divert collected water down concealed side downspouts and out the sill.051 (19 x 1. Blades are reinforced with full length integral bosses for superior strength and the design provides good air performance through it’s 51% free area as well as maximum protection against the elements. FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 3 Dimensions are in inches (mm). 1" [25] to overall louver depth). preventing it from flowing down into the airstream. ❑ AN04 Clear Anodized 204-R1. FINISH: Mill. . with good air performance and pleasing aesthetics that compliment any structure’s exterior styling. HEIGHT – 1/4" (6) STD.S.080" (2. Color Anodized: ❑ ANLB Light Bronze. Undersize 1/2" (12. Color: ______________ .03R 1604DD 1604DD February. NO M. 1 1/2" (38) BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. to 50% Kynar ® ). ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equiv. ❑ ANMB Medium Bronze.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size. 1" (25) Filter Rack. 70 sq. STANDARD CONSTRUCTION: FRAME: 4" (102) deep. Larger louvers will require field assembly of smaller sections. Nailor Industries Inc. Insect Screen. Reinforced with 1" x 1" (25 x 25) angle (adds approx.2 . ❑ ANDB Dark Bronze. WI DT H– 1/4 " (6 )S TD . inside (rear) mount (adds approximately 3/8" [10] to louver depth). 4" (102) MAX. reserves the right to change any information concerning product or pricing without notice. High Performance Powder Coat AAMA 2604 (Equiv. Undersize 3/8" (9. ENGINEER: CONTRACTOR: DATE B SERIES 2 .7). BLADES: Type 6063-T5 extruded aluminum. No Bird Screen. SCREEN: 3/4" x . BLADE SPACING: Approx. ______________ . Model 1604DD. Color: ___________ . Perimeter Anchor Clips. with reinforcing bosses. 4" (102) on centers. (6. Integral downspouts and caulking slot provided. Type 6063-T5 extruded aluminum. provides maximum weather protection in a 4" (102) deep frame. BLADE ANGLE: Fixed at 37 degrees. factory installed on rear of louver on maximum 48" (1219) centers. MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide.03) nominal wall thickness. Aluminum Insect Screen. Color: ___________ .S.080" (2. Suitable for use in exhaust and low to medium velocity intake applications. Type 304 S. Standard construction features a drainable head that collects the water running down the building face and channels it out the concealed downspouts in the side frame. SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048).5m 2). ft. 2011.03) nominal wall thickness.22 . . to 70% Kynar ® ). MINIMUM SIZE: 12" W x 12" H (305 x 305). flattened aluminum bird screen in removable frame. ❑ ANBK Black. Bird Screen.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • DUAL DRAINABLE BLADE MODEL: 1604DD NOM. dual drainable blade type louver. Type 304 S. Previous View SUPERSEDES DRAWING NO. 2" (51) Filter Rack. ❑ PCC Prime Coat.5). 76 0.29 2.96 1.15 2.42 0.25 22.13 51.18 2.41 42 1.42 17.00 36.07 0.07 1.40 38.86 7.44 21.81 17.09 0.21 0.69 5.82 1.57 0.13 5.11 2.47 2.03 9.27 27.26 0.77 0.73 16.97 2.86 1.30 0.22 0.71 7.97 16.31 0.07 0.62 9.05 6.06 6.07 4.13 1.05 1.94 5.21 1.40 2.85 0.81 2.46 0.36 6.65 0.77 0.08 120 4.57 21.92 96 3.35 2.48 0.05 4.00 1.77 16.89 7.44 0.75 0.98 15.81 20.28 1.84 17.79 51.37 0.63 1.04 1.23 0.00 2.74 0.22 1.67 0.60 16.20 12.99 26.37 3.79 1.12 3.81 1.05 28.93 3.91 0.25 2.29 2.88 30.13 2.72 0.24 0.10 11.65 0.38 1.49 1.47 6.08 2.72 0.70 21.81 27.71 0.90 0.59 34.05 2.97 18.83 42.06 0.09 34.20 0.43 19.82 0.89 1.08 3.52 23.57 6.05 16.90 13.40 0.86 14.04 22.14 0.79 0.02 6.48 10.72 2.58 1.60 0.62 2.85 6.20 1.05 0.53 37.03 3.25 4.55 5.42 0.15 0.02 6.97 2.69 0.00 13.07 3.99 1.83 0.04 8.53 0.23 0.06 1.41 4.80 7.44 0.90 30.13 2.47 28.10 2.32 10.43 1.32 3.00 2.07 21.38 0.91 2.15 3.66 0.99 17.46 1.29 3.25 1.90 0.61 21.26 18 0.2 .56 0.37 0.30 0.43 1.19 0.77 10.78 114 4.87 1.69 13.11 3.23 15.68 7.83 2.82 5.44 4.60 33.40 0.62 14.76 18.85 1.55 0.14 9.06 17.27 0.43 36.65 1.93 2.67 90 3.11 0.23 8.83 3.55 39.65 5.13 1.98 2.12 10.05 4.31 32.26 1.35 0.79 2.03 21.47 7.49 1.97 1.17 31.93 13.86 1.76 0.80 11.22 0.48 0.58 3.88 2.42 10.07 1.35 5.76 0.26 5.24 1.18 1.22 102 4.42 14.09 0.68 1.50 0.27 60 2.73 0.61 0.58 5.73 0.22 38.39 0.07 1.53 1.03 27.92 3.05 4.20 0.75 37.23 0.91 0.51 23.86 2.62 1.33 4.19 2.74 2.72 7.87 10.87 6.17 2.13 2.35 24.69 2.21 19.26 9.46 1.76 1.94 23.34 49.16 22.23 1.24 5.97 9.17 8.92 6.33 7.57 0.48 8.83 9.27 3. Previous View SUPERSEDES DRAWING NO.37 1.80 3.35 1.01 6.51 1.32 1.30 16.73 1.35 12.39 11.29 31.13 0.77 2.63 31.33 48.11 35.78 10.47 0.84 4.38 9.98 2.90 40.69 2.98 1.98 1.44 0.72 2.72 1.35 1.58 1.77 4.74 45.19 2.39 5.17 48.23 2.29 0.93 1.21 27.17 0.65 0.98 29.47 25.68 2.04 42.53 0.07 1.14 6.05 0.47 0.52 10.96 29.56 1.15 7.16 5.56 0.37 3.35 0.82 1.55 11.91 54.66 1.95 17.52 18.40 13.83 2.76 0.83 19.23 38.97 4.19 0.52 2.53 3.31 4.33 0.02 0.15 6.73 1.31 1.80 2.42 3.61 0.34 0.56 22.39 2.01 1.00 1.86 1.26 0.99 1.45 0.29 2.12 3.45 15.90 3.18 12.08 2.29 4.06 16.26 0.87 8.51 66 2.22 0.17 8.32 3.08 1.14 16.05 1.30 14.17 1.43 0.80 0.16 3.24 1.84 3.78 9.36 1.96 7.20 14.36 7.31 4.94 24.36 43.17 0.49 2.29 0.75 2.57 51.61 4.88 29.62 0.21 0.16 0.32 31.05 12 0.53 108 4.66 1.56 0.69 0.07 0.43 0.32 3.84 0.35 2.51 2.07 1.73 0.52 1.06 5.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • DUAL DRAINABLE BLADE PERFORMANCE DATA MODEL: 1604DD FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.85 43.32 25.92 2.53 0.95 43.27 1.22 1.34 25.29 2.60 0.49 3.80 9.19 21.25 14.05 5.14 15.66 48.18 10.41 0.80 10.93 1.50 31.98 0.92 36.32 24.34 0. reserves the right to change any information concerning product or pricing without notice.46 20.15 2.51 2.41 15.18 24.65 0.89 19.88 1.23 0.11 36 1.94 3.15 1.58 12.14 0.13 5.61 35.95 31.49 33.81 1.04 22.75 1.51 1.78 43.17 29.45 12. 2011.26 28.52 3.56 3.54 21.56 46.60 0.46 33.56 2.07 19.68 16.40 2.81 4.24 0.70 3.99 2.33 2.70 0.88 41.59 0.47 2.21 17.32 14.38 0.67 26.50 2.92 24.61 10.19 0.69 2.61 2.83 1.51 33.00 1.78 5.30 4.80 4.65 0.39 1.07 4.66 32.01 4.37 0.26 2.16 45.37 2.68 0.74 2.24 2.36 28.69 10.49 54. Performance Specification .33 1.54 0.52 35.51 12.89 3.79 4.47 0.27 1.59 2.23 2.42 17.05 0.44 3.91 30.87 3.76 3.58 4.44 33.88 0.91 39.45 6.60 26.37 84 3.91 36.13 1.38 0.85 46.73 20.32 SCHEDULE TYPE: PROJECT: Page 2 of 3 Dimensions are in inches (mm).46 1.52 0.15 0.33 0.59 2.91 1.50 11.66 48 1.10 1.09 4.46 0.71 24.62 2.67 14.48 27.64 0.80 4.34 2.69 15.55 0.46 2.40 57.63 7.52 0.43 18.20 3.37 1.69 1.42 7.72 11.08 7.46 0.80 4.30 8.63 0.51 4.54 1.96 54 2.86 3.42 1.93 3.47 12.31 0.32 0.57 0.49 29.53 1.67 21.14 1.19 1. ENGINEER: CONTRACTOR: DATE B SERIES 2 .32 0.91 3.49 1.27 0.99 20.61 2.10 0.56 4.09 7.18 0.12 0.67 0.32 11.42 20.03 0.14 1.77 8.58 11.10 26.48 2.41 13.41 0.35 1.00 2.66 1.38 3.90 9.45 23.31 0.16 14.72 3.29 0.94 1.04 2.11 1.88 25.77 1.51 0.86 2.13 2.68 1.97 1.31 0.58 14.08 0.01 3.11 0.55 19.45 18.11 0.53 1.15 0.15 3.79 13.82 0.34 1.49 1.54 0.74 22.88 1.12 1.76 8.30 14.51 2.93 6.54 40.72 38.41 1.92 3.10 15.92 18.33 2.54 13.73 5.35 0.77 0.60 2.24 4.33 40.76 12.50 0.62 1.30 3.49 15.70 6.44 2.28 9.53 4.31 1.49 0.38 0.25 1.65 25.61 0.06 2.39 11.61 3.87 0.48 0.60 11.83 72 2.67 5.54 16.98 1.68 0. Nailor Industries Inc.05 2.26 0.06 78 3.62 1.11 1600 Home Contents Dimensions 9 .23 0.00 40.21 8.56 46.13 0.13 12.21 1.03R 1604DD 1604DD February.94 30 1.36 0.17 1.14 0.59 20.43 22.83 3.59 24 0.26 25.51 10.51 19.95 1.01 12.17 .72 0.36 25.69 8.83 0.54 2.43 3.55 2.44 2.45 1.28 27.19 0.69 27.87 13.38 5.74 32.44 35. Previous View 2000 3000 (609. Nailor Industries Inc. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.6) .4) . m.30 (74. (sq.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO.6) 1000 fpm (305 m/min.6) (914) Performance Specification .) 8140 cfm (3841 l/s) .4) 1000 (304.70 (174. SCHEDULE TYPE: PROJECT: Page 3 of 3 Dimensions are in inches (mm).0) . ENGINEER: CONTRACTOR: DATE B SERIES 2 .76) Static Pressure Drop in Inches w.02 (5.01 oz.2 .03 (7.7) INTAKE OR EXHAUST .9) ./sq.01 (2.2) .5) 200 300 (61. reserves the right to change any information concerning product or pricing without notice.0 (248.0) .17 . . ft.0) (91.03R 1604DD 1604DD February. (40 Pa) NOTE: To minimize water penetration when sizing intake louvers.3) .50 (124.8) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).075 lbs/ft 3 . ft. 2011. (Pa) I N T A K E Free Area % Free Area sq.4) . select a Free Area Velocity that is below the point of beginning water penetration. w.05 (12.14 (0.g.EXTRUDED ALUMINUM STATIONARY LOUVER 4" (102) DEEP • DUAL DRAINABLE BLADE PERFORMANCE DATA MODEL: 1604DD AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 51% 8.40 (99.16 in. (3 ml/sq. test duration) Air Volume at 1000 fpm Free Area Velocity Pressure Drop @ 1000 fpm 1. 9 .60 (149.10 (24.4) 500 (152.5) .20 (49. Nailor Industries certifies the Model 1604DD shown herein is licensed to bear the AMCA Seal. Seal applies to air performance ratings and water penetration ratings.) Free Area Velocity at Point of Beginning Water Penetration at . Standard air density @ 0. m) (15 min.g. (6.EXTRUDED ALUMINUM STATIONARY LOUVER 6" (152) DEEP • DUAL DRAINABLE BLADE MODEL: 1606DD NOM. inside (rear) mount (adds approximately 3/8" [10] to louver depth). Color: ______________ . STANDARD CONSTRUCTION: FRAME: 6" (152) deep. Model 1606DD is a dual drainable blade type louver that provides maximum weather protection.5). MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide. Insect Screen. Perimeter Anchor Clips. ❑ ANMB Medium Bronze. Color: ______________ . 70 sq. NO M. good air performance and aesthetics that compliment any building design. ❑ ANBK Black. With the beginning point of water penetration at 1193 fpm (6. factory installed on rear of louver on maximum 48" (1219) centers. OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. 1" (25) to overall louver depth). MINIMUM SIZE: 12" W x 12" H (305 x 305).5m 2).22 . Larger louvers will require field assembly of smaller sections. High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ).080" (2. preventing it from flowing down into the airstream.06 m/s) free area velocity. Larger assemblies require separate visible frames with downspouts. 1 1/2" (38) BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. 2011. Integral downspouts and caulking slot provided. 2" (51) Filter Rack. Aluminum Insect Screen. Nailor Industries Inc. ❑ ANDB Dark Bronze. ______________ . 6" (152) MAX. No Bird Screen.080" (2.03) nominal wall thickness. Type 304 S. FINISH: Mill. . Undersize 1/2" (12. ❑ PCC Prime Coat. the dual drainable blade design utilizes double rain gutters that divert collected water down concealed side downspouts and out the sill.051 (19 x 1. Type 304 S. Model 1606DD is engineered for maximum protection from the elements and is AMCA Licensed. HEIGHT – 1/4" (6) STD. SCREEN: 3/4" x . ❑ AN04 Clear Anodized 204-R1. Performance Specification . Type 6063-T5 extruded aluminum. BLADE ANGLE: Fixed at 37 degrees. ft. SCHEDULE TYPE: PROJECT: Page 1 of 3 Dimensions are in inches (mm).S. Available with channel or flanged type frame to suit most architectural and mechanical installation requirements. Undersize 3/8" (9.S. Suitable for use in exhaust and low to medium velocity intake applications. Color Anodized: ❑ ANLB Light Bronze.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 FLANGED FRAME (FL) (OPTIONAL) Exact Size. SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). flattened aluminum bird screen in removable frame. with reinforcing bosses. Bird Screen. reserves the right to change any information concerning product or pricing without notice. BLADES: Type 6063-T5 extruded aluminum. the design allows for optimal weather protection at higher airflow rates.11 1600 Home Contents Dimensions 9 . BLADE SUPPORT BRACKETS: Concealed type. Blades are reinforced with full length integral bosses for superior strength and the design exhibits low pressure drop characteristics throughout the full airflow range. WI DT H– 1/4 " (6 )S TD . 1" (25) Filter Rack. Color: ______________ .03) nominal wall thickness. 6" (152) on centers.03R 1606DD 1606DD February. ❑ AN15 Clear Anodized 215-R1. Previous View SUPERSEDES DRAWING NO.2 . Reinforced with 1" x 1" (25 x 25) angle (adds approx. ENGINEER: CONTRACTOR: DATE B SERIES 2 . . Standard construction features a drainable head that collects the water running down the building face and channels it out the concealed downspouts in the side frame.3) expanded. BLADE SPACING: Approx.7). ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. Welded Construction. EXTRUDED ALUMINUM LOUVER 6" (152) DEEP • DUAL DRAINABLE BLADE PERFORMANCE DATA MODEL: 1606DD FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.30 0.46 0.61 0.76 0.91 1.07 1.22 1.37 1.52 1.68 1.83 1.98 2.13 2.29 2.44 2.59 2.74 2.90 3.05 12 0.18 0.29 0.39 0.50 0.61 0.72 0.82 0.93 1.04 1.15 1.25 1.36 1.47 1.58 1.68 1.79 1.90 2.01 2.11 0.30 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.20 18 0.43 0.69 0.95 1.21 1.47 1.73 1.99 2.25 2.51 2.77 3.03 3.29 3.55 3.81 4.07 4.33 4.59 4.85 5.11 0.46 0.04 0.06 0.09 0.11 0.14 0.16 0.19 0.21 0.23 0.26 0.28 0.31 0.33 0.35 0.38 0.40 0.43 0.45 0.47 24 0.69 1.10 1.51 1.92 2.33 2.75 3.16 3.57 3.98 4.40 4.81 5.22 5.63 6.04 6.46 6.87 7.28 7.69 8.10 0.61 0.06 0.10 0.14 0.18 0.22 0.26 0.29 0.33 0.37 0.41 0.45 0.48 0.52 0.56 0.60 0.64 0.68 0.71 0.75 11.16 30 0.95 1.51 2.08 2.65 3.22 3.78 4.35 4.92 5.49 6.05 6.62 7.19 7.76 8.32 8.89 9.46 10.02 10.59 0.76 0.09 0.14 0.19 0.25 0.30 0.35 0.40 0.46 0.51 0.56 0.62 0.67 0.72 0.77 0.83 0.88 0.93 0.98 1.04 36 1.21 1.93 2.65 3.37 4.10 4.82 5.54 6.27 6.99 7.71 8.44 9.16 9.88 10.60 11.33 12.05 12.77 13.50 14.22 0.91 0.11 0.18 0.25 0.31 0.38 0.45 0.51 0.58 0.65 0.72 0.78 0.85 0.92 0.99 1.05 1.12 1.19 1.25 1.32 42 1.46 2.34 3.22 4.10 4.98 5.86 6.74 7.62 8.50 9.37 10.25 11.13 12.01 12.89 13.77 14.65 15.53 16.41 17.28 1.07 0.14 0.22 0.30 0.38 0.46 0.54 0.63 0.71 0.79 0.87 0.95 1.03 1.12 1.20 1.28 1.36 1.44 1.52 1.61 48 1.72 2.76 3.79 4.83 5.86 6.90 7.92 8.96 10.00 11.03 12.07 13.10 14.14 15.17 16.21 17.24 18.27 19.31 20.34 1.22 0.16 0.26 0.35 0.45 0.54 0.64 0.74 0.83 0.93 1.03 1.12 1.22 1.31 1.41 1.51 1.60 1.70 1.79 1.89 54 1.98 3.17 4.36 5.55 6.74 7.93 9.12 10.31 11.50 12.69 13.88 15.07 16.26 17.45 18.64 19.83 21.02 22.21 23.40 1.37 0.18 0.29 0.41 0.52 0.63 0.74 0.85 0.96 1.07 1.18 1.29 1.40 1.51 1.62 1.73 1.84 1.95 2.06 2.17 60 2.30 3.68 5.06 6.44 7.81 9.19 10.57 11.95 13.33 14.71 16.09 17.47 18.85 20.22 21.60 22.98 24.36 25.74 27.12 1.52 0.21 0.34 0.47 0.60 0.73 0.85 0.98 1.11 1.24 1.37 1.49 1.62 1.75 1.88 2.01 2.14 2.26 2.39 2.52 66 2.50 4.00 5.50 7.01 8.51 10.01 11.51 13.01 14.51 16.01 17.52 19.02 20.52 22.02 23.52 25.02 26.52 28.03 29.53 1.68 0.23 0.37 0.51 0.65 0.79 0.93 1.07 1.21 1.35 1.49 1.63 1.77 1.91 2.05 2.19 2.32 2.46 2.60 2.74 72 2.77 4.44 6.10 7.76 9.43 11.09 12.75 14.42 16.08 17.74 19.41 21.07 22.73 24.40 26.06 27.72 29.39 31.05 32.71 1.83 0.26 0.41 0.57 0.72 0.88 1.03 1.18 1.34 1.49 1.65 1.80 1.96 2.11 2.27 2.42 2.58 2.73 2.88 3.04 78 3.02 4.83 6.65 8.46 10.27 12.09 13.90 15.71 17.53 19.34 21.15 22.96 24.78 26.59 28.40 30.22 32.03 33.84 35.65 1.98 0.28 0.45 0.62 0.79 0.95 1.12 1.29 1.46 1.63 1.80 1.96 2.13 2.30 2.47 2.64 2.81 2.98 3.14 3.31 84 3.28 5.25 7.22 9.19 11.15 13.12 15.09 17.06 19.03 21.00 22.97 24.93 26.90 28.87 30.84 32.81 34.78 36.74 38.71 2.13 0.30 0.49 0.67 0.85 1.04 1.22 1.40 1.58 1.77 1.95 2.13 2.32 2.50 2.68 2.86 3.05 3.23 3.41 3.60 90 3.54 5.66 7.79 9.91 12.04 14.16 16.28 18.41 20.53 22.66 24.78 26.90 29.03 31.15 33.28 35.40 37.52 39.65 41.77 2.29 0.33 0.53 0.72 0.92 1.12 1.32 1.51 1.71 1.91 2.10 2.30 2.50 2.70 2.89 3.09 3.29 3.49 3.68 3.88 96 3.80 6.08 8.36 10.64 12.92 15.20 17.48 19.76 22.04 24.32 26.60 28.88 31.16 33.44 35.72 38.00 40.28 42.56 44.84 2.44 0.35 0.56 0.78 0.99 1.20 1.41 1.62 1.84 2.05 2.26 2.47 2.68 2.89 3.11 3.32 3.53 3.74 3.95 4.17 102 4.06 6.49 8.93 11.36 13.80 16.24 18.67 21.11 23.54 25.98 28.41 30.85 33.28 35.72 38.15 40.59 43.02 45.46 47.89 2.59 0.38 0.60 0.83 1.06 1.28 1.51 1.73 1.96 2.19 2.41 2.64 2.87 3.09 3.32 3.54 3.77 4.00 4.22 4.45 108 4.32 6.91 9.50 12.09 14.68 17.27 19.87 22.46 25.05 27.64 30.23 32.82 35.41 38.00 40.60 43.19 45.78 48.37 50.96 2.74 0.40 0.64 0.88 1.12 1.36 1.60 1.85 2.09 2.33 2.57 2.81 3.05 3.29 3.53 3.77 4.01 4.25 4.49 4.73 114 4.58 7.32 10.07 12.82 15.56 18.31 21.06 23.80 26.55 29.30 32.04 34.79 37.54 40.28 43.03 45.77 48.52 51.27 54.01 2.90 0.43 0.68 0.94 1.19 1.45 1.70 1.96 2.21 2.47 2.72 2.98 3.23 3.49 3.74 4.00 4.25 4.51 4.76 5.02 120 4.84 7.74 10.64 13.54 16.45 19.35 22.25 25.15 28.06 30.96 33.86 36.76 39.66 42.57 45.47 48.37 51.27 54.18 57.08 3.05 0.45 0.72 0.99 1.26 1.53 1.80 2.07 2.34 2.61 2.88 3.15 3.42 3.68 3.95 4.22 4.49 4.76 5.03 5.30 SCHEDULE TYPE: PROJECT: Page 2 of 3 Dimensions are in inches (mm). ENGINEER: CONTRACTOR: DATE B SERIES 2 - 2 - 11 1600 Home Contents Dimensions 9 - 17 - 03R 1606DD 1606DD February, 2011. Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice. Previous View SUPERSEDES DRAWING NO. Performance Specification EXTRUDED ALUMINUM LOUVER 6" (152) DEEP • DUAL DRAINABLE BLADE PERFORMANCE DATA MODEL: 1606DD AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 50% 7.92 (0.74) Static Pressure Drop in Inches w.g. (Pa) I N T A K E Free Area % Free Area sq. ft. (sq. m.) Free Area Velocity at Point of Beginning Water Penetration at .01 oz./sq. ft. (3 ml/sq. m) (15 min. test duration) Air Volume at 1193 fpm Free Area Velocity Pressure Drop @ 1193 fpm 1.0 (248.6) 1193 fpm (364 m/min.) 9449 cfm (4459 l/s) .18 in. w.g. (45 Pa) NOTE: To minimize water penetration when sizing intake louvers, select a Free Area Velocity that is below the point of beginning water penetration. Nailor Industries Inc. certifies the Model 1606DD shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. Seal applies to air performance ratings and water penetration ratings. .70 (174.0) .60 (149.2) .50 (124.3) .40 (99.4) .30 (74.6) .20 (49.7) INTAKE .10 (24.9) .05 (12.4) .03 (7.5) .02 (5.0) .01 (2.5) 200 300 (61.0) (91.4) 500 (152.4) 1000 (304.8) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm). Standard air density @ 0.075 lbs/ft 3 . Page 3 of 3 Dimensions are in inches (mm). SCHEDULE TYPE: PROJECT: ENGINEER: CONTRACTOR: DATE B SERIES 2 - 2 - 11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO. 9 - 17 - 03R 1606DD 1606DD February, 2011. Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice. Previous View 2000 3000 (609.6) (914) Performance Specification EXTRUDED ALUMINUM STATIONARY LOUVER WIND-DRIVEN RAIN RESISTANT 5" (127) DEEP • HORIZONTAL BLADE MODEL: 1605WD (1605DD) NOM. HEIGHT – 1/4" (6) STD. Model 1605WD wind-driven rain horizontal drainable blade louver provides maximum weather protection in a 5" (127) deep frame, with pleasing sight-proof aesthetics that compliment any structure’s exterior styling. Suitable for use in exhaust and low to medium velocity intake applications, the drainable head and drainable blade design divert collected water down concealed side downspouts and out the sill. Blades are reinforced with full length integral bosses for superior strength and the 5" (127) deep channel type frame installs easily in most common wall configurations. Model 1605WD is AMCA Licensed for wind-driven rain and is engineered to be architecturally appealing as well as mechanically enduring. STANDARD CONSTRUCTION: FRAME: 5" (102) deep, Type 6063-T5 extruded aluminum, .080" (2.03) nominal wall thickness. Integral downspouts and caulking slot provided. BLADES: Type 6063-T5 extruded aluminum, .080" (2.03) nominal wall thickness, with reinforcing bosses. BLADE ANGLE: Fixed at 30 degrees. BLADE SPACING: Approx. 2" (51) on centers. BLADE SUPPORT BRACKETS: Concealed type, factory installed on rear of louver on maximum 48" (1219) centers. Reinforced with 1" x 1" (25 x 25) angle (adds approx. 1" [ 25] to overall louver depth). MULLIONS: Concealed type allowing continuous line appearance up to 120" (3048) wide. Larger assemblies require separate visible frames with downspouts. SCREEN: 3/4" x .051 (19 x 1.3) expanded, flattened aluminum bird screen in removable frame, inside (rear) mount (adds approximately 3/8" [10] to louver depth). FINISH: Mill. MINIMUM SIZE: 12" W x 12" H (305 x 305). NO M. MAX. SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). 70 sq. ft. (6.5m 2). Larger louvers will require field assembly of smaller sections. BSSS BSN ISA ISSS WE Type 304 S.S. Bird Screen. No Bird Screen. Aluminum Insect Screen. Type 304 S.S. Insect Screen. Welded Construction. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: DT H– 1/4 " (6 )S TD . 5" (127) OPTIONS: ❑ ❑ ❑ ❑ ❑ WI Extended Sill. 1" (25) Filter Rack. 2" (51) Filter Rack. Perimeter Anchor Clips. ______________ . OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. Color: ______________ . ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). Color: ______________ . ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Color: ______________ . ❑ PCC Prime Coat. ❑ AN04 Clear Anodized 204-R1. ❑ AN15 Clear Anodized 215-R1. Color Anodized: ❑ ANLB Light Bronze. ❑ ANDB Dark Bronze. BIRD SCREEN ❑ ANMB Medium Bronze. ❑ ANBK Black. OPTIONAL W x H SIZING (1/4" [6.5] Undersize standard): ❑ U00 ❑ U38 ❑ U50 Exact Size. Undersize 3/8" (9.5). Undersize 1/2" (12.7). SCHEDULE TYPE: PROJECT: Page 1 of 3 Dimensions are in inches (mm). ENGINEER: CONTRACTOR: DATE B SERIES 2 - 2 - 11 1600 Home Contents Dimensions 1605DD-1 4 - 28 - 08 1605WD 1605WD February, 2011. Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice. Previous View SUPERSEDES DRAWING NO. Performance Specification 39 4.71 0.50 0.67 1.12 8.80 0.40 38.92 2.70 0.01 1.25 40.28 0.54 0.05 35.22 50.53 0.65 18.78 0.80 0.90 12.48 42 1.74 24.39 2.26 0.05 3.15 3.82 12.01 1.86 12.40 20.22 35.89 21.96 22.72 0.83 49.47 15.99 7.68 0.35 1.35 0.75 6.54 10.46 0.26 5.17 2.04 2.92 3.35 0.50 6.02 9.31 11.95 1.94 1.96 6.21 0.40 0.33 0.98 1.82 8.29 3.05 3.80 3.38 18 0.84 20.21 8.62 5.44 0.75 1.94 40.02 1.48 0.44 17.27 15.46 16.58 1.25 2.59 29.10 1.77 33.75 2.52 8.56 2.38 2.58 1.23 0.94 43.55 1.35 2.37 8.12 4.37 0.10 0.64 29.EXTRUDED ALUMINUM STATIONARY LOUVER WIND DRIVEN RAIN RESISTANT 5" (127) DEEP • HORIZONTAL BLADE PERFORMANCE DATA MODEL: 1605WD (1605DD) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.41 42.71 41.35 45.98 13.65 0.26 1.99 3.60 1.26 3.12 1.60 3.76 48 1.83 0.25 20.84 21.89 1.83 22.01 1.32 1.72 19.31 0.99 1.52 0.87 2.92 55.99 1.13 2.43 2.97 3.13 2.13 0.80 39.97 1.25 26.47 3.59 20.25 1.02 18.61 0.45 31.85 8.91 1.91 4.22 33.33 14.12 9.15 33.14 1.12 21.43 11.17 15.06 18.91 13.04 13.19 36 1.07 0.43 84 3.01 2.95 3.65 3.24 11.73 0.64 2.99 10.12 14.34 0.54 3.48 23.48 17.79 4.05 54 2.73 7.34 18.95 34.10 13.95 2.72 27.93 36.81 0.33 1.53 0.98 2.95 2.61 0.17 0.48 3.16 0.57 2.87 2.20 11.59 0.51 0.59 10. Previous View SUPERSEDES DRAWING NO.49 1.15 0.21 2.67 1.72 30.37 0.91 1.77 5.00 5.31 2.19 3.02 2.65 2.84 3.09 2.57 2.11 1.89 9.43 1.42 0.13 16.37 1.69 5.54 0.82 2.87 1.68 1.39 0.03 4.60 3.74 2.57 4.24 1.28 0.02 7.62 1.96 8.02 2.28 19.74 2.63 4.09 3.32 1.52 2.76 0.47 12.11 1600 Home Contents Dimensions 1605DD-2 4 .46 37.50 24.29 3.52 0. ENGINEER: CONTRACTOR: DATE B SERIES 2 .64 3.09 6.89 38.12 4.09 17.67 24 0.86 26.24 0.58 0.14 1.42 8.18 2.30 0.46 6.25 14.88 4.35 4.15 2.81 20.46 0.35 3.22 16.91 3.89 4.44 32.56 0.09 0.16 0.21 0.43 0.46 33.28 2.34 0.25 1.74 0.08 1605WD 1605WD February.46 24.69 18.91 1.49 31.23 1.83 2.33 46.40 0.47 SCHEDULE TYPE: PROJECT: Page 2 of 3 Dimensions are in inches (mm).45 29.13 0.01 10.81 3.85 0. Performance Specification .30 0.43 13.18 3.43 15.15 1.24 15.89 55.67 4.24 8.66 0.58 0.55 0.06 1.76 2.95 1.53 1.42 10.74 1.40 2.96 1.43 0.72 2.65 0.39 47.71 2.17 0.84 19.18 6.87 7.60 15.45 29.35 8.33 1.84 25.36 1.12 1.28 6.19 2.06 0.09 0.47 1.45 7.33 3.43 1.90 2.40 22.28 0.98 1.20 0.53 13.56 25.55 1.66 13.36 16.95 3.55 3.92 5.08 0.62 0.22 1.81 4.30 0.79 4.79 12.35 1.59 14.76 1.91 1.63 0.81 27.05 0.40 1.76 0.71 8.35 14.69 0.34 0.91 10.97 23.03 4.97 23.41 2.21 6.40 3.33 0.14 4.88 0.70 4.03 0.70 9.28 60 2.81 11.72 2.51 39.97 19.07 1.46 39.12 0.74 1.76 34.05 52.91 5.23 1.59 0.88 12.53 2.00 13.54 2.31 2.71 1.43 10.05 2. Nailor Industries Inc.20 14.49 0.82 1.77 0.95 37.85 12.75 2.2 .84 1.95 96 3.60 0.15 5.71 12.24 13.10 36.88 1.08 36.30 1.05 11.41 6.39 1.67 90 3.71 14.26 0.36 5.13 3.52 47.05 1.21 20.27 31.26 3.30 0.67 2.08 4.24 21.82 0.85 44.53 5.52 26.61 8.32 0.00 28.72 18.35 0.57 66 2.40 3.74 0.86 4.09 21.19 0.45 2.31 41.08 27.60 15.61 3.50 0.19 5.73 6.28 .04 16.98 16.15 25.18 1.76 29.55 44.15 0.75 0.93 46.49 0.69 9.44 19.41 1.66 0.88 114 4.59 8.63 9.99 2.99 3.23 5.91 3.86 72 2.08 1.52 1.41 1.31 2.97 22.17 1.22 7.63 15.96 28.40 0.23 1.32 0.03 2.13 0.17 3.13 29.73 19.27 4.67 2.34 1.28 0.27 0.94 4.07 3.83 11.96 31.46 0.53 1.59 0.70 0.28 27.13 2.38 3.63 5.22 0.44 1.55 1.46 0.69 0.15 78 3.22 0.22 1.38 4.38 4.16 33.05 2.41 0.00 5.52 1.01 1.39 30.35 33.55 27.84 23.55 1.19 49.99 2.90 3.45 27.70 1.29 36.54 17.05 12 0.74 2.79 7.35 5.24 6.65 1.83 0.96 25.49 1.64 9.66 1.87 2.61 31.22 2.39 3.11 0.18 2.88 4.79 2.42 7.44 2.18 1.55 2.44 21.69 2.47 31.23 0.84 1.39 9.24 102 4.30 6.81 20.14 17.83 0.50 0.47 2.09 38.44 2.39 0.29 2.90 3.18 22.11 3.91 3.46 7.65 6.58 108 4.15 2.27 27.72 7.16 16.65 6.05 18.85 1.27 1.72 24.66 1.46 0.77 0.45 31.84 17.65 0.33 24.18 120 4.34 19.25 3.74 2.39 0.69 1.39 13.61 10.57 0.60 18.86 2.42 3.80 5.51 2.42 2.07 1.49 2.32 1.11 1.47 0.88 1.18 2.89 0.46 14.68 0.83 10.22 0.90 0.59 2.75 3.65 22.35 0.07 1.23 15.46 35.97 1.58 0.91 58.59 1.28 12.05 0.24 0.57 1.62 0.93 49.21 7.20 30.80 4.60 5.16 1.26 0.86 52.30 0.34 2.79 1.74 0.86 20.83 1.76 10.58 0.48 12.06 23.70 1.19 10.41 1.13 0.07 0.52 3.08 6.36 4. 2011.43 9.95 3.43 0.28 8.81 1.81 2.28 2. reserves the right to change any information concerning product or pricing without notice.25 0.81 3.45 25.40 7.92 52.56 10.09 9.88 0.76 0.61 0.87 0.17 12.72 41.44 0.40 1.78 30 1.08 23.97 16.13 25.29 0.63 0.65 2.36 9.23 1.72 2.09 1.78 34.64 1.94 2.03 43.39 1.67 0.83 36.49 16.19 0.09 0.09 18.01 1.82 7.19 0.36 2.22 16.94 7.36 0.19 9.68 0.55 2.20 5.29 27.96 24.65 4.80 1.18 0.07 15.14 3.67 3.28 4.31 0.43 0.91 0.44 23.13 1.78 0.82 44.44 17.97 1.42 5.64 4.82 28.18 41.35 2.60 0.98 0.23 13.36 0.03 1.08 2.13 0.35 10.44 0.84 1.20 0. 7) INTAKE . select a Free Area Velocity that is below the point of beginning water penetration. DISCHARGE LOSS COEFFICIENT CLASS (INTAKE):2 (Discharge Loss Coefficient Classification is as follows: 1=0.64 (0. Previous View SUPERSEDES DRAWING NO. Nailor Industries Inc.80) 1025 fpm (312 m/min.0) (91.10 (24.375" (1. (3 ml/sq.) 500 (152.0) Free Area Ventilation 0 Rate in fpm (m/s) (0.5) 545 (2.6) . ft.0) 1091 (5.5) 97.7 B Static Pressure Drop in Inches w.2 . (80 Pa) NOTE: To minimize water penetration when sizing intake louvers.8 A 492 (2. Standard air density @ 0.4 and above.) 8856 cfm (4179 l/s) .5) 200 300 (61. w.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm). 4 = 0.70 (174. water penetration and wind driven rain performance ratings.375" x 39. Seal applies to air performance.g.0) Effectiveness Ratio (%) 100 Penetration Class A 98 (0.4) .2) .EXTRUDED ALUMINUM STATIONARY LOUVER WIND DRIVEN RAIN RESISTANT 5" (127) DEEP • HORIZONTAL BLADE PERFORMANCE DATA MODEL: 1605WD (1605DD) PRESSURE DROP AIRFLOW / WATER PENETRATION DATA 1.5) 181 (0. WIND DRIVEN RAIN PERFORMANCE Core Ventilation 0 Rate in fpm (m/s) (0. certifies the Model 1605WD shown herein is licensed to bear the AMCA Seal.20(298. ft.5) 98.4) Test was based on a 39.40 (99.01 oz.03 (7. (sq.05 (12.0) 727 (3.60 (149.g.5) 908 (4. Nailor Industries Inc. m.30(323. reserves the right to change any information concerning product or pricing without notice.0 (248.2) I N T A K E Free Area % Free Area sq. SCHEDULE TYPE: PROJECT: Page 3 of 3 Dimensions are in inches (mm).5 B 689 (3.08 1605WD 1605WD February.6 A 394 (2.6) . ENGINEER: CONTRACTOR: DATE B SERIES 2 .0 m) core area louver tested at a rainfall rate of 3" per hour (76 mm/hour) with a wind velocity of 29.28 .8) 2000 3000 (609.7) 99.3) 1. m) (15 min.3 A 591 (3.0) 364 (1.299.0) . 2=0.9) .2 to 0. test duration) Air Volume at 1025 fpm Free Area Velocity Pressure Drop @ 1025 fpm 54% 8./sq.5) 1272 (6.4) 1000 (304. 3 = 0.20 (49. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.199 and below.4) .075 lbs/ft 3 .50 (124.399.3 to 0.11 1600 Home Contents Dimensions 1605DD-2 4 .8) 99.8) 100 A 295 (1.) Free Area Velocity at Point of Beginning Water Penetration at . 2011.0 m x 1.1 mph (13 m/s).3) .9) 100 A 197 (1.30 (74.6) 99. Performance Specification . (Pa) for 48" x 48" (1219 x 1219) Louver Size 1.32 in. Aluminum Insect Screen. Color: ______________ . plated steel. MAX. at 37 1/2° angle (fully open). Undersize 1/2" (12. ❑ AN04 Clear Anodized 204-R1. BEARINGS: 1/2" (13) dia. HEIGHT – 1/4" (6) STD. BLADE SPACING: Approx. No Jamb Seals. 4" (102) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BPV JSN BSSS BSN ISA ISSS WE Flanged Frame. Larger sizes will be manufactured in sections with visible mullion side frame (downspouts are concealed) for field assembly. Perimeter Anchor Clips. reserves the right to change any information concerning product or pricing without notice. NO M. ENGINEER: CONTRACTOR: DATE B SERIES 2 . Color Anodized: ❑ ❑ 1 1/2" (38) ANMB Medium Bronze. Integral downspouts and caulking slot provided. AXLES: 1/2" (13) dia. Insect Screen. Model 1604AD provides adjustable flexibility as well as maximum protection against the elements.080" (2.2 . Color: ______________ . Other: _____________ . . The blades can be operated manually or with an actuator to provide tight shut-off when desired. PVC Blade Seals. . Bird Screen. 4" (102) on centers.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 Exact Size. the design features a drainable blade with rain gutters that divert collected water down concealed side downspouts and out the sill.5). BLADES: Type 6063-T5 extruded aluminum. 2" (51) Filter Rack. Color: ______________ . ACTUATOR: Hand locking louver quadrant. ❑ ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC ACT Extended Sill. 60" W x 96" H (1524 x 2438) (Without Seals). Electric or Pneumatic Actuator. inside (rear) mount (adds approximately 3/8" [10] to louver depth). ❑ AN15 Clear Anodized 215-R1. BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6.11 1600 Home Contents Dimensions NEW 1604AD 1604AD February. JAMB SEALS: Compression type cambered metal.EXTRUDED ALUMINUM ADJUSTABLE LOUVER 4" (102) DEEP • DRAINABLE BLADE MODEL: 1604AD NOM.03) nominal wall thickness. Welded Construction. Specify: ______________ . Type 304 S. 2011. with reinforcing bosses. No Bird Screen. Previous View SUPERSEDES DRAWING NO.051 (19 x 1. S. ANBK Black. WI DT H– 1/4 " (6 )S TD . SINGLE SECTION SIZE: 48" W x 96" H (1219 x 2438) (With Blade and/or Jamb Seals). Undersize 3/8" (9.03) nominal wall thickness. FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). Type 304 S. Blades are reinforced with full length integral bosses for superior strength and the design exhibits low pressure drop characteristics throughout the airflow range.3) expanded. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). OPTIONAL FINISHES: ❑ ❑ PC3 PC4 ❑ ❑ ANLB Light Bronze. S. ANDB Dark Bronze. Type 6063-T5 extruded aluminum. stainless steel sleeve type. Powder Coat AAMA 2603. Model 1604AD adjustable. Concealed in frame. Nailor Industries Inc.080" (2. FINISH: Mill. flattened aluminum bird screen in removable frame. Suitable for use in exhaust and low to medium velocity intake applications. 1" (25) Filter Rack. SCREEN: 3/4" x . STANDARD CONSTRUCTION: FRAME: 4" (102) deep.7). ❑ PCC Prime Coat. drainable blade type louver combines superior weather protection and architecturally pleasing aesthetics with airflow control including tight shut-off. MINIMUM SIZE: 12" W x 12" H (305 x 305). High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). LINKAGE: Plated steel. Performance Specification . 30 0.60 0. Nailor Industries Inc.87 10.01 oz.20 3.76 36 0.14 1.01 (2) 1.4) 1000 (304.88 0.37 60 1.0) (91.2) 10. test duration) Air Volume at 953 fpm Free Area Velocity Pressure Drop @ 953 fpm 1.03 0.06 0.84 0.91 0.00 1.81 0.45 0.70 (175) .9) .76 0.82 0.13 1.44 12 0.66 7.59 7.01 1.50 0.29 3.g. ft.52 0.41 4.93 1.16 1.30 (75) .00 1.69 0.75 0. (sq.05 (12.18 2. .37 1.2) (15.92 44% 7.23 3.71 0.0 (248.6) Static Pressure Drop in Inches w.50 (125) PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size Free Area % Free Area sq.g.4) 1.0 (101.39 0.23 2.10 (0.05 1.98 0.26 4.38 0.73 0.5) .66) 953 fpm (290 m/min.40 0.15 2.77 0.11 12.46 0.77 0.38 0.23 2.22 2.24 1.91 11.04 0.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO.11 1.59 18.33 0.99 0.08 1.20 1.69 1.09 1.68 30 0.47 24 0.20 (49.96 1.0 (25.31 3.95 0. ENGINEER: CONTRACTOR: DATE B SERIES 2 .74 0.36 0.81 0. (3 ml/sq.52 6.03 (7) .12 1.30 3.07 1.06 1.24 3.51 6.0 (5.075 lbs/ft 3 .2 (L / s / m 2) Louver test size: 48" x 48" (1219 x 1219 mm) with blade and jamb seals.56 0.73 8.56 0.22 0.0) .07 1.31 15.04 12.41 4.81 9.71 8.73 0.77 9.39 0.13 1.67 0.54 6.15 1.13 1.47 1.52 1.09 1.87 0.13 90 2. 2011.10 1.79 9.12 2.10 0.28 15.40 5. ft.46 24 .29 4.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).82 0.72 0.04 0.89 36 0.09 1.0 (10.23 0.49 0.41 16.78 1.29 0.90 0.02 0.18 2.37 0.16 1.15 1. (52 Pa) NOTE: To minimize water penetration when sizing intake louvers.56 0.90 0.04 12.36 16.2 .86 10.0 (50.19 2.06 0. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.91 10.04 0. Tested to AMCA Fig.16 2.22 1.21 0.61 0.18 2.20 (50) .00 11.69 1.) 6766 cfm (3193 l/s) .36 4.14 1. (Pa) I N T A K E .49 17.27 3.53 0.7) INTAKE .12 0.01 (2.44 5.43 0.51 0. Page 2 of 2 Dimensions are in inches (mm).30 0.0 3.43 0.40 (99.35 4.29 96 2.46 0.72 60 1.28 0.4) 500 (152.4) .60 (150) . Nailor Industries Inc.31 0.81 9.23 1.36 0.07 48 1.08 0.03 (7.60 7.46 6.0) .02 (5) .5) 200 300 (61.02 12.34 0.78 1.61 7.60 0.67 19. reserves the right to change any information concerning product or pricing without notice.52 66 1.91 11.0 (500) 12 .8) 20. Seal applies to air performance ratings and water penetration ratings.35 0.40 5.47 5.41 0.37 4.25 3.53 17.31 4.g.21 in.58 7.10 0.68 72 1.27 0.38 0. certifies the Model 1604AD shown herein is licensed to bear the AMCA Seal.27 0.82 0. m) (15 min.76 0. NEW 1604AD 1604AD February.90 0.13 2.39 0.26 14.54 0.27 18 0.70 (174.58 7.51 AIRFLOW / WATER PENETRATION DATA 54 1.95 10.59 1.1) 2.) Free Area Velocity at Point of Beginning Water Penetration at . m.38 4.78 20.67 0.31 0.80 9.30 0.80 0.74 0.95 1.10 (24.82 9.50 5.14 13.66 8.20 14. SCHEDULE TYPE: PROJECT: .45 0.6) Leakage in CFM / ft.51 0.06 0.01 0.21 14.27 3.46 0.44 5.60 (149.13 13.77 0./sq.41 0.92 0.30 48 1.00 0. Standard air density @ 0.36 4.73 1.16 13.03 1.91 42 1.30 (74.15 2.40 (100) .93 0. select a Free Area Velocity that is below the point of beginning water penetration.46 1.07 0.71 0.05 (13) .50 1.15 0.77 8.65 7.65 8.96 0.36 4.22 54 1.60 0.77 0.10 (25) .23 3. 5.59 6.30 0.61 0.6) .61 0.61 30 .56 0.EXTRUDED ALUMINUM ADJUSTABLE LOUVER 4" (102) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1604AD AIR LEAKAGE (Damper fully closed) FREE AREA in Square Feet and Square Meters 2.16 0.45 5.8) 2000 3000 (609.40 16.3) .04 0. (Pa) Height in Inches and Meters Width in Inches and Meters Performance Specification .10 1.20 2.25 2. w.4) .18 2.44 5.42 5.51 7.26 1.07 0.09 42 1.0 (250) Static Pressure in Inches w.32 3.63 7.69 8.30 18 .24 0.12 0.98 84 2.02 11.87 0.08 0.58 0.5 – 6.53 0.21 2.50 (124.02 (5.2) . Previous View 5.91 0.92 1.64 0.54 6.83 0.83 78 1.69 8.96 11.5.35 4.06 1.49 0.52 6.25 0. OPTIONAL W x H SIZING (1/4" [6. ANBK Black. ANDB Dark Bronze. .5). Bird Screen. ❑ AN04 Clear Anodized 204-R1.080" (2. Type 6063-T5 extruded aluminum. 2011. PVC Blade Seals. 1" (25) Filter Rack. Concealed in frame. the design features a drainable blade with rain gutters that divert collected water down concealed side downspouts and out the sill. Larger sizes will be manufactured in sections with visible mullion side frame (downspouts are concealed) for field assembly. flattened aluminum bird screen in removable frame.EXTRUDED ALUMINUM ADJUSTABLE LOUVER 6" (152) DEEP • DRAINABLE BLADE MODEL: 1606AD NOM. ❑ AN15 Clear Anodized 215-R1. Suitable for use in exhaust and low to medium velocity intake applications. FINISH: Mill. No Bird Screen. Electric or Pneumatic Actuator. Color Anodized: ❑ ❑ PC3 PC4 ANLB Light Bronze. ACTUATOR: Hand locking louver quadrant. HEIGHT – 1/4" (6) STD. BLADE SPACING: Approx. ❑ ❑ 1 1/2" (38) BIRD SCREEN ANMB Medium Bronze. Performance Specification . Nailor Industries Inc. MINIMUM SIZE: 12" W x 12" H (305 x 305). Integral downspouts and caulking slot provided. Previous View SUPERSEDES DRAWING NO. 60" W x 96" H (1524 x 2438) (Without Seals). Model 1606AD adjustable. Undersize 1/2" (12.080" (2. SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). LINKAGE: Plated steel. 6" (152) on centers. stainless steel sleeve type. plated steel. Color: ______________ . MAX. . No Jamb Seals. S.7). STANDARD CONSTRUCTION: FRAME: 6" (152) deep.051 (19 x 1. Undersize 3/8" (9. ENGINEER: CONTRACTOR: DATE B SERIES 2 .11 1600 Home Contents Dimensions NEW 1606AD 1606AD February. 2" (51) Filter Rack.2 . BLADES: Type 6063-T5 extruded aluminum. The blades can be operated manually or with an actuator to provide tight shut-off when desired.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 FLANGED FRAME (FL) (OPTIONAL) Exact Size. S.3) expanded. BEARINGS: 1/2" (13 ) dia. AXLES: 1/2" (13 ) dia. at 37 1/2° angle (fully open). Insect Screen. ❑ ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC ACT Extended Sill. Aluminum Insect Screen. Perimeter Anchor Clips. Type 304 S. Type 304 S. NO M. Model 1606AD provides adjustable flexibility as well as maximum protection against the elements. Welded Construction. High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). with reinforcing bosses. reserves the right to change any information concerning product or pricing without notice.03) nominal wall thickness. WI DT H– 1/4 " (6 )S TD . ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). drainable blade type louver combines superior weather protection and architecturally pleasing aesthetics with airflow control including tight shut-off. Other: _____________ . Color: ______________ . OPTIONAL FINISHES: ❑ ❑ Powder Coat AAMA 2603. inside (rear) mount (adds approximately 3/8" [10] to louver depth). JAMB SEALS: Compression type cambered metal. 6" (152) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BPV JSN BSSS BSN ISA ISSS WE Flanged Frame. ❑ PCC Prime Coat. SINGLE SECTION SIZE: 48" W x 96" H (1219 x 2438) (With Blade and/or Jamb Seals). Color: ______________ . Blades are reinforced with full length integral bosses for superior strength and the design exhibits low pressure drop characteristics throughout the airflow range.03) nominal wall thickness. SCREEN: 3/4" x . Specify: ______________ . 83 9.42 16./sq.67 2. NEW 1606AD 1606AD February.87 0.38 0.37 60 1.5.55 0.10 2.7) INTAKE .27 0.32 0.17 in.09 2.42 0.60 (150) .10 1.71 8.64 8.20 0.03 (7.88 0.15 1.56 7.12 13. (Pa) I N T A K E .21 0.81 0.5 – 6.22 0.02 1.6) .48 5.11 0.97 36 0.25 14.94 1.74 1.35 0.41 0.52 1.54 0.21 2.0 (101.51 17. certifies the Model 1606AD shown herein is licensed to bear the AMCA Seal.91 1.) 7906 cfm (3731 l/s) .10 1. (3 ml/sq.58 6.22 14.30 (74. test duration) Air Volume at 970 fpm Free Area Velocity Pressure Drop @ 970 fpm 1.28 0.01 (2) 1.50 (125) PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size Free Area % Free Area sq. ft.93 11.59 6.41 5.16 0.35 4.65 0.44 5.05 0.77 0.14 1.20 (49.13 1.33 4.4) .99 12.13 90 2.80 0.18 2.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO.81 20.37 1.02 (5) .40 (99.39 5.2) 10.90 10.4) .02 0.4) 1. ft.63 7.86 10.55 0.50 0.22 3.08 1.53 0.33 4.03 0.57 0.45 5.79 1. Previous View 5.22 0. .30 0.0 (25.14 2.67 8.30 15.50 (124.63 0.69 0.97 0. Standard air density @ 0.43 48 1.25 2.66 0.23 3. 5.37 16.27 4.10 (24.85 9.31 3.88 60 1.66 0.67 0.25 1.33 0.05 (12.37 4.03 0.64 7.35 1.03 11.91 0.69 0.31 4.25 0.59 0.27 0.0 (248.21 0.07 48 1.04 0.05 0.42 1.70 (175) .37 0.25 0.51 0.35 5.35 15.15 0.46 24 .91 1.95 11.27 3.03 12.9) .41 4.96 0.30 (75) .48 17.30 3.92 1. Page 2 of 2 Dimensions are in inches (mm).48 0.16 2.07 0.18 2.60 (149.06 1.76) 970 fpm (296 m/min.13 2. reserves the right to change any information concerning product or pricing without notice.15 0.68 72 1.40 6.0 3.45 6.28 4. Nailor Industries Inc.22 0.46 0.20 2.75 9.87 10.17 0.8) 2000 3000 (609.11 12.65 0.40 (100) .70 (174.54 6.90 0.) Free Area Velocity at Point of Beginning Water Penetration at .25 3.83 78 1.29 96 2.02 0.71 9.86 0.67 0.77 0.01 1.91 42 1.19 2.91 0.53 17. Nailor Industries Inc.77 8.75 30 0.01 (2.86 10.61 18.26 0.48 0.71 0.01 oz.46 1.05 0.79 1.2 (L / s / m 2) Louver test size: 48" x 48" (1219 x 1219 mm) with blade and jamb seals. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.23 0.41 0.5) .98 0.95 0.66 19.20 (50) .075 lbs/ft 3 .58 7.3) .44 12 0.0) .07 1.12 2.6) Leakage in CFM / ft.89 0.56 6. (sq.5) 200 300 (61.52 24 0. Tested to AMCA Fig.4) 1000 (304.34 4.27 3.63 0.g.EXTRUDED ALUMINUM ADJUSTABLE LOUVER 6" (152) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1606AD AIR LEAKAGE (Damper fully closed) FREE AREA in Square Feet and Square Meters 2.2 .22 14.10 1.00 1.76 9.22 1.07 1.40 4.03 0.34 1.51 0.30 18 .05 1. Seal applies to air performance ratings and water penetration ratings.26 0.32 15. m.58 7.07 12. SCHEDULE TYPE: PROJECT: .13 0.41 0. m) (15 min.23 0.22 0.52 66 1.57 1.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).27 0.07 1.35 0.27 3.22 54 1.61 30 .49 5.88 0.15 (0.92 0.12 13.0 (250) Static Pressure in Inches w.52 6.94 22.79 0.76 9. ENGINEER: CONTRACTOR: DATE B SERIES 2 .73 20.98 84 2.23 2.14 1.04 1.06 0. (42 Pa) NOTE: To minimize water penetration when sizing intake louvers.67 8.25 3.69 8.72 0.98 11.97 0.12 0.46 5.29 18 0.16 1.12 1.0 (5.21 2. select a Free Area Velocity that is below the point of beginning water penetration.87 0.03 (7) .48 6.20 42 1. w.24 0.20 0.41 0.0 (500) 12 .6) Static Pressure Drop in Inches w.43 1.97 0.0) (91.39 0.63 7.76 0.07 0.1) 2.28 0.02 (5.16 1.47 0.g.65 AIRFLOW / WATER PENETRATION DATA 54 1.15 1.53 0.30 1. 2011. (Pa) Height in Inches and Meters Width in Inches and Meters Performance Specification .07 0.g.19 2.05 (13) .70 0.83 0.8) 20.59 0.24 2.61 0.78 0.28 0.19 14.0) .01 0.10 (25) .33 0.54 0.11 51% 8.51 6.86 0.2) (15.23 1.4) 500 (152.25 0.70 8.88 10.25 0.99 12.43 0.2) .39 4.0 (10.55 1.0 (50.49 6.17 2.73 0.78 9.67 1.76 36 0.10 1.81 0.11 13.86 1. WI DT H– 1/4 " (6 )S TD . Nailor Model 1606CDAF is an extruded aluminum combination louver and damper that incorporates front stationary drainable blades and rear adjustable airfoil blades all within a single frame. Bird Screen. ❑ AN04 Clear Anodized 204-R1. ❑ ❑ ❑ ❑ ❑ FR1 1" (25) Filter Rack. Color: ______________ . 3/4" x . . . Color: ______________ . Color: ______________ . Insect Screen. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). 2011. BLADE SEALS: Silicone. 6" (152) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL Flanged Frame. Type 304 S.18) nominal wall thickness. BLADE SPACING: Approx. ❑ ANDB Dark Bronze. ACTUATOR: Hand locking louver quadrant. MINIMUM SIZE: 12" W x 16" H (305 x 406). Aluminum Insect Screen.125" (3.051 (19 x 1. OPTIONAL FINISHES: PC3 PC4 Powder Coat AAMA 2603.5] Undersize standard): ❑ ❑ U00 U50 Exact Size. BSSS BSN ISA ISSS WE ESI Type 304 S. inside (rear) mount (adds approximately 3/8" [10] to louver depth). No Bird Screen.5). BIRD SCREEN 1 1/2" (38) LISTED SIZE + 2 3/4" (70) ❑ ❑ Undersize 3/8" (9.03) nominal wall thickness. Perimeter Anchor Clips.S. Extended Sill. Rear operable blades: Airfoil style. High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ).3) expanded.09 1606CDAF 1606CDAF February. Previous View SUPERSEDES DRAWING NO. BEARINGS: 1/2" (13) dia. Color Anodized: ❑ ANLB Light Bronze. JAMB SEALS: Cambered stainless steel. ❑ AN15 Clear Anodized 215-R1. BLADE ANGLE: Front blades fixed at 45 degrees.7). ENGINEER: CONTRACTOR: DATE B SERIES 2 . Specify: ______________ .11 1600 Home Contents Dimensions 5 . Oilite ® self-lubricating bronze. ❑ PCC Prime Coat. flattened aluminum bird screen in removable frame. Concealed in frame. ❑ U38 Undersize 1/2" (12. Performance Specification . BLADES: Front stationary blades: drainable style.080" (2. Larger sizes will be manufactured in sections with visible mullion side frame (downspouts are concealed) for field assembly. Blades are reinforced with full length integral bosses for strength. OPTIONAL FLANGED FRAME (FL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). NO M. Electric or Pneumatic Actuator. ❑ ANBK Black. Model 1606CDAF is available with channel or flanged type frame to suit most installation requirements. The design provides efficient air performance and aesthetics that compliment any building exterior. 5 1/2" (140) on centers. reserves the right to change any information concerning product or pricing without notice. The drainable blades provide excellent weather protection for exhaust and low to medium velocity intake air applications by utilizing rain gutters to divert collected water down concealed side downspouts and out the sill. Integral downspouts and caulking slot provided.29 . SINGLE SECTION SIZE: 60" W x 96" H (1524 x 2438). ❑ ANMB Medium Bronze. STANDARD CONSTRUCTION: FRAME: 6" (152) deep type 6063-T5 extruded aluminum. and is licensed by AMCA for assured performance. MAX. FR2 PAC ACT 2" (51) Filter Rack.S. plated steel double bolted to blades. type 6063-T5 extruded aluminum. while providing tight shut-off when no airflow is required.EXTRUDED ALUMINUM COMBINATION LOUVER/DAMPER 6" (152) DEEP • DRAINABLE BLADE OPERABLE AIRFOIL DAMPER MODEL: 1606CDAF NOM. AXLES: LINKAGE: SCREEN: 1/2" (13) dia. OPTIONAL W x H SIZING (1/4" [6. type 6063-T5 extruded aluminum.2 . HEIGHT – 1/4" (6) STD. Welded Construction. FINISH: Mill. Other: ______________ . Nailor Industries Inc. Mechanically locked in place. 08) 2.57 4.05 (13) . Standard air density @ 0.52 0. w.34 6.08 0.70 (175) .22 15.46 84 2.70 (175) .50 0.99 5. Nailor Industries Inc.52 16.34 0.70 1.08 11. (3 ml/sq.55 19.20 13.11 0.40 1.16 1.06 3.54 0.71 10.99 9. Nailor Industries Inc.55 0.24 1. Seal applies to air performance ratings and water penetration ratings.52 0.03 16.50 11.0 4.17 0.51 0. select a Free Area Velocity that is below the point of beginning water penetration.81 54 1.0 (500) for 48" x 48" (1219 x 1219) Louver Size I N T A K E .97 9.37 0.45 0.42 0.55 10.41 13.68 0.73 48 1.43 1.13 0.30 1.00 11.09 0.45 0.16 0.10 (25) . ft.19 in.20 (50) .49 5.12 0.29 0.10 1.15 1.42 0.79 2.96 1. (Pa) 43% 6.52 18.02 0.67 0. certifies the Model 1606CDAF shown herein is licensed to bear the AMCA Seal.73 0.60 (150) .0 (500) 12 18 24 30 36 42 48 54 60 0.3 (1.62 42 1.17 0.38 7.44 17.93 1.36 2.86 0.74 1.26 0. m) (15 min.28 0.80 2.5 (2.55 5.13 0.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO.01 0.79 0.) 7868 cfm (3713 l/s) .2 0.16 5.25 0.12 0.25 0.02 (5) 200 300 (61.79 10. (Pa) Height in Inches and Meters Width in Inches and Meters Performance Specification .56 0.54 12.0) (91.25 0.03 (7) .15 0.72 96 2.61 0.02) (1.20 (50) .64 4.05 0.g.55 0.46 0.23 1.48 3.0 (5.11 4.76 3.07 1.2 (L / s / m 2) Louver test size: 48" x 48" (1219 x 1219 mm).53 14.40 (100) .64) 1142 fpm (348 m/min.82 8.55 0.5 – 6.01 12.4) 1000 (304.54) 2.67 2.61 0.18 3.71 2./sq.97 60 1.34 4.52 16 0.62 12.36 0.56 2.39 0.97 5.72 0. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.45 2.93 10.48 12.99 1.55 0.43 3.56 6.49 0.61 0.66 0.10 (25) .84 1. (sq.14 0.64 3.42 0.88 1.66 2.32 0.48 7.87 5.37 0.32 0.59 0.02 1.94 6.48 0.04 2.91 0.36 0.44 0.83 4.50 (125) PRESSURE DROP AIRFLOW / WATER PENETRATION DATA Free Area % Free Area sq.63 1.02 1.19 0.10 0.41 0.27 6.74 0.8) 2000 3000 4000 (609.69 4.05 (13) .36 30 0.97 4.00 6.31 10. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).51 5.03 7.22 2.57 0.42 0. reserves the right to change any information concerning product or pricing without notice.78 9.18 9.40 (100) . Tested to AMCA Fig.01 oz.83 0.07 0.21 0.99 1.82 0.73 4. 5 .20 0.98 1. Previous View 0.10 0.37 0.37 1.93 1.51 2.94 7.29 0.11 0.83 Static Pressure Drop in Inches w.22 2.) Free Area Velocity at Point of Beginning Water Penetration at .52) 1.31 14.68 0.29 .26 0.07 1. test duration) Air Volume at 1142 fpm Free Area Velocity Pressure Drop @ 1142 fpm 1.85 6. ft. 2011.34 0.07 0.65 0.47 36 0.24 8.70 0.06 0.14 1.94 2.20 0.89 1.46 4.64 0.60 (150) .30 15.50 (125) INTAKE OR EXHAUST .20 0.59 8. 5.g.19 72 1.5.56 7.86 1.53 1.30 0.27 0.03 0.29 0.60 0.98 0.95 3.6) (914) (1219) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).57 3. .46 0.20 1.17 0.30 (75) .22 0.69 78 2.35 1.24 0.28 24 0.16 1.52 14.32 15.94 1.83 0.06 8.33 8.42 0.EXTRUDED ALUMINUM COMBINATION LOUVER/DAMPER 6" (152) DEEP • DRAINABLE BLADE OPERABLE AIRFOIL BLADE PERFORMANCE DATA MODEL: 1606CDAF AIR LEAKAGE (Damper fully closed) FREE AREA in Square Feet and Square Meters 2.16 3.05 4.46 0.06 1.07 1.36 0.22 0.2 .76 0.03 (7) .42 0.05 0.18 7.09 0.04 1.0 (600) (900) (1200) Leakage in CFM / ft.65 0.88 1.31 0.91 1.39 1.10 3.79 3.g.09 11.07 0.29 0.69 3.76 0.76 0.0 (250) Static Pressure in Inches w.59 11.22 0.22 0.72 0.89 7.25 1.38 3.24 0.89 (0.38 0. m.075 lbs/ft 3 .13 0.57 90 2. (47 Pa) NOTE: To minimize water penetration when sizing intake louvers.18 0.4) 500 (152.90 0.81 0.09 0.22 1.22 0.02 (5) .68 0.34 2.97 6.94 7.01 (2) 0.04 0.30 1.43 1.56 5.82 5.32 0.56 8.30 (75) .13 0. ENGINEER: CONTRACTOR: DATE B SERIES 2 .52 0.88 3.79 3.0 3.06 0.17 6.38 1.77 1.12 20 0.97 7.83 0.18 0.85 2. 1.09 1606CDAF 1606CDAF February.04 66 1.00 1.17 4.0 (250) . Fiberglass blade insulation provides good sound absorption and the closely centered multiple formed J blade design is sightproof and provides excellent weather protection. SCREEN: 3/4" x . STANDARD CONSTRUCTION: ACOUSTICAL INSULATION: Fiberglass. Perforated interior retains and protects internal insulation.10 .11 1600 Home Contents Dimensions 1612AD-1 1 . ENGINEER: CONTRACTOR: DATE B SERIES 2 . ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). WI DT H– 1/4 " (6 )S TD .5). reserves the right to change any information concerning product or pricing without notice Previous View SUPERSEDES DRAWING NO.080" (2. Welded Construction. FINISH: Mill. BLADE ANGLE: Fixed at 45 degrees. 2" (51) Filter Rack. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Formed aluminum. Undersize 3/8" (9.08 1612QS 1612QS February. Color: ______________ . .03) nominal thickness. Type 304 S. 12" (305) 1 1/2" (38) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. Color: ______________ . NO M. BLADE SPACING: Approximately 6 1/2" (165) on centers. NOM. 1" (25) Filter Rack.ACOUSTICAL LOUVER • SIGHTPROOF 12" (305) DEEP • FORMED ALUMINUM MODEL: 1612QS (1612AD) Model 1612QS acoustical louver combines the most effective sound attenuation performance with protection from the elements in an architecturally pleasing design. MAX.S. Larger louvers will require field assembly of smaller sections. Performance Specification . ____________ . FRAME: 12" (305) deep. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ FL BSSS BSN ISA ISSS WE Flanged Frame. MINIMUM SIZE: 12" W x 18" H (305 x 457). Color: ______________ . ❑ AN04 Clear Anodized 204-R1.3) expanded. 2011.03) nominal thickness. BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. FLANGED FRAME (FL) (OPTIONAL) Color Anodized: ❑ ANLB Light Bronze.051" (19 x 1. as required. ❑ ANDB Dark Bronze. HEIGHT – 1/4" (6) STD. No Bird Screen. Bird Screen. ❑ ANBK Black. ❑ AN15 Clear Anodized 215-R1. Undersize 1/2" (12. ❑ ❑ ❑ ❑ ❑ ESI FR1 FR2 PAC Other: Extended Sill. ❑ PCC Prime Coat. SINGLE SECTION SIZE: 60" W x 96" H (1524 x 3048).5] Undersize standard): ❑ U00 ❑ U38 ❑ U50 Exact Size. Insect Screen. Type 304 S. ❑ ANMB Medium Bronze. Perimeter Anchor Clips. Aluminum Insect Screen. SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). MULLIONS: Visible type.080" (2.7). BLADES: Formed aluminum. depending upon width.S. flattened aluminum bird screen in removable frame (adds approximately 3/8" [10] to louver depth). Nailor Industries Inc. The model is suitable for either intake or exhaust applications and the 30% free area provides good air performance throughout the airflow range. .2 . 06 0.05 0.10 0.61 0.39 0.45 0.30 (74.58 5.71 0.60 0.52 0.09 0.97 1.22 0.5) 13 200 300 (61.74 0.03 90 2.70 (174.67 9.08 3.10 (24.43 2.50 3.08 2.56 0.06 1. Performance Specification .78 3.49 0.0) .52 0.34 0.10 .71 3.95 3.08 0.g. m.46 0.2 .82 0.22 0.05 0.69 0.90 6.39 1.66 0.04 1. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.58 10.37 42 0.28 0.92 1.01 oz.90 6.27 0.52 0.03 0.13 9.74 2.22 8.12 in.51 5.44 0.32 7.40 2. Standard air density @ 0.5) .83 12.30 0.71 0.47 48 1.59 0.55 0.44 0.74 2.21 0.26 0.56 6.90 1. FREE FIELD NOISE REDUCTION Octave Band (Frequency)(Hz) Free Field Noise Reduction (db) Transmission Loss (db) 2 (125) 11 5 3 (250) 11 5 4 (500) 16 10 5 (1000) 25 19 6 (2000) 20 14 7 (4000) 19 13 Sound Transmission Class Static Pressure Drop in Inches w.0 (248.07 0.21 0.91 2.15 0.03 0.18 0.4) 1000 (304.19 0.55 0.6) 30% 4.25 0.15 0.09 24 0.46 0.46 1.0) .03 1./sq. ENGINEER: CONTRACTOR: DATE B SERIES 2 .97 6.61 4.82 4.94 7.22 3.43 0.19 8.93 11.29 2.13 0.6) . The higher the STC rating number. 2011.99 4.83 7.87 1.08 1612QS 1612QS February.52 18 0.2) .59 0. reserves the right to change any information concerning product or pricing without notice Previous View Nailor Industries certifies the Model 1612QS shown herein is licensed to bear the AMCA Seal.91 3.25 0.84 0.09 2.18 0.18 0. (3 ml/sq.77 2.94 84 1.16 0.81 2.26 3.67 2.11 0.08 0. ft.33 4.03 (7.60 1.45 0. select a Free Area Velocity that is below the point of beginning water penetration.47 3.01 1.59 6.26 0.05 0.78 9.84 0.06 0.16 0.67 0.07 1.91 1. Air Performance and Sound ratings.06 4.31 0.22 1.05 1.34 0. test duration) Air Volume at 978 fpm Free Area Velocity Pressure Drop @ 978 fpm .60 (149.76 0.25 7.22 0.02 0.79 (0.54 4.45 0.17 0.23 0.16 0.01 0.37 0.07 0.80 0.39 7.83 1.20 (49.44 4.4) 500 (152.17 4.35 0.35 6.76 0.53 1.67 0.07 0.61 0.82 4.58 0.13 4. 1612AD-2 1 .) Free Area Velocity at Point of Beginning Water Penetration at .04 1.32 0.56 2.36 2.96 1.92 3.37 0. m) (15 min.05 (12.33 9.38 0.22 AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 1. Louver test size: 48" x 48" (1219 x 1219 mm).50 0.69 1.15 0.26 0.07 72 1. w.65 0.13 0.74 0.68 0.32 7.78 3.19 0.07 1.14 0.99 9.08 0.02 0.7) INTAKE .11 0.0) (91.39 2.64 8.3) .86 5.11 0.03 0.08 2.40 (99.35 0.91 0.40 4.50 0.56 54 1.38 11.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area NOTE: The Sound Transmission Class (STC) is a single number rating of the louver’s resistance to transfer airbourne sound.21 0.01 (2.9) .75 0.08 2.29 0.28 0.31 6.30 0.27 0.03 10.89 1.19 3. (sq.65 0.23 0.g.17 0.28 36 0.05 0.94 78 1.94 2.79 5.11 1600 Home Contents Dimensions SUPERSEDES DRAWING NO.13 0.38 5.08 8.38 0.18 1.33 0.03 10. The AMCA Certified Ratings Seal applies to Water Penetration.32 0.76 0.13 0.12 96 2.36 0.10 0.84 0.01 0.50 (124. calculated in accordance with ASTM E413-04. ft.52 0.67 3.59 0.075 lbs/ft 3 . the less sound is transmitted through the louver.46 0.09 1. (29.83 0.42 6.18 0.59 0.42 0.39 0.41 0.) 4680 cfm (2208 l/s) .4) .99 9.45 0. (Pa) I N T A K E Free Area % Free Area sq.72 5.04 0.8 Pa) NOTE: To minimize water penetration when sizing intake louvers.20 5.86 5.75 66 1.94 7.49 0.28 0.61 4.84 10. Nailor Industries Inc.06 1.65 60 1.4) . SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).06 3.15 1.49 7.11 1.39 1.74 13.02 (5.37 1.14 0.8) 2000 3000 (609.94 2.77 0.32 0.03 1.54 0.35 0.78 3.89 4.22 1.ACOUSTICAL LOUVER • SIGHTPROOF 12" (305) DEEP • FORMED ALUMINUM PERFORMANCE DATA MODEL: 1612QS (1612AD) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0.19 30 0.98 0.45) 977 fpm (298 m/min.86 5. Undersize 3/8" (9. ❑ PCC Prime Coat. STANDARD CONSTRUCTION: FRAME: Type 6063-T5 extruded or formed aluminum. Previous View Home Contents Dimensions Performance Specification 1600CSC . W CG OPTIONAL FINISHES: ❑ ❑ PC3 PC4 Powder Coat AAMA 2603. Bird Screen. 1 1/2" (38) TYPICAL CHANNEL FRAME (STANDARD) OPTIONAL W x H SIZING (1/4" [6. Undersize 1/2" (12.051 (19 x 1. SCREEN: 3/4" x . Insect Screen. PAC Perimeter Anchor Clips. Other: ______________ . FINISH: Mill. SCHEDULE TYPE: PROJECT: Dimensions are in inches (mm). Aluminum Insect Screen.10 1600 SUPERSEDES DRAWING NO. ❑ ANBK Black. flattened aluminum bird screen in removable frame. Contact Nailor for special configurations or requirements.SPECIALTY STATIONARY LOUVERS EXTRUDED ALUMINUM CIRCULAR & SEMICIRCULAR SHAPES MODEL SERIES: 1600 Nailor specialty shape louvers are available in a variety of blade/frame designs. Reinforced with 1" x 1" (25 x 25) vertical angle (adds approximately 1" [25] to overall louver depth).21 . The following louver models are available in specialty shapes as shown: 1602J (SB) 1604J 1604D (SD) 1606J 1606D (SD) 1602K (SR) 1604JD (SB) 1604DD 1606JD (SB) 1606DD 1604KD (SR) 1606KD (SR) Note: Use of drainable blades is not recommended on certain shapes. H OPTIONS: ❑ ❑ ❑ ❑ FL BSSS BSN ISA Flanged Frame. Contact Nailor for smaller sizes. ❑ ❑ ❑ ISSS Type 304 S. Specialty shape louvers are not licensed to bear the AMCA seal. Color: ______________ . Performance of specialty shape louvers may vary from that of standard louvers. Type 304 S.10 Nailor Industries Inc. No Bird Screen. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ).5). BLADES: Type 6063-T5 extruded aluminum.S.S. Contact Nailor for specific details. BLADE SUPPORT BRACKETS: Concealed type. ❑ AN15 Clear Anodized 215-R1. factory installed on rear of louver as necessary. 1600CSC-1 7 . Color: ______________ . Color: ______________ . reserves the right to change any information concerning product or pricing without notice.5] Undersize standard): ❑ ❑ ❑ U00 U38 U50 OPTIONAL FLANGED FRAME (FL) Exact Size. Frame profile may vary depending upon louver style and shape. D W CA CB H H W W CC CD H H H1 H1 W W CE CF MAXIMUM SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" H x 120" W (2134 x 3048). Larger louvers will require field assembly of smaller sections. H PERFORMANCE: Standard louvers are tested for water penetration and pressure drop in a square configuration only. See applicable louver model submittal sheet for blade profile.7). inside (rear) mount (adds approximately 3/8" [10] to louver depth). High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). ❑ ANDB Dark Bronze. ❑ ANMB Medium Bronze. MINIMUM SIZE: 20" Diameter (508). Channel type standard. Color Anodized: ❑ ANLB Light Bronze. ENGINEER: CONTRACTOR: DATE B SERIES 11 .3) expanded. ❑ AN04 Clear Anodized 204-R1. Consult Nailor for section details of specific sizes.15 . Consult Nailor for specific applications. W2 W1 W TJ 1 1/2" (38) OPTIONAL W x H SIZING (1/4" [6.5). ❑ ANDB Dark Bronze. Larger louvers will require field assembly of smaller sections.S. H H PERFORMANCE: Standard louvers are tested for water penetration and pressure drop in a square configuration only. reserves the right to change any information concerning product or pricing without notice. Contact Nailor for specific details. Color Anodized: ❑ ANLB Light Bronze.10 1600 SUPERSEDES DRAWING NO. W W TG TH H2 OPTIONAL FINISHES: ❑ ❑ H1 H PC3 PC4 Powder Coat AAMA 2603. Consult Nailor for specific applications. Bird Screen. Insect Screen.10 Nailor Industries Inc.051 (19 x 1. SCREEN: FINISH: 3/4" x . Reinforced with 1" x 1" (25 x 25) vertical angle (adds approximately 1" [25] to overall louver depth). Type 304 S. BLADES: BLADE SUPPORT BRACKETS: Concealed type. ❑ ANMB Medium Bronze. W W TC TD H H H1 H1 W W TE TF MAXIMUM SINGLE SECTION SIZE: 120" W x 84" H (3048 x 2134) or 84" W x 120" H (2134 x 3048). No Bird Screen. Specialty shape louvers are not licensed to bear the AMCA seal. Aluminum Insect Screen. U38 Undersize 3/8" (9. W1 H H OPTIONS: ❑ ❑ ❑ ❑ FL BSSS BSN ISA Flanged Frame. factory installed on rear of louver as necessary. ❑ ANBK Black. U50 Undersize 1/2" (12.SPECIALTY STATIONARY LOUVERS EXTRUDED ALUMINUM TRIANGULAR & TRAPEZOIDAL SHAPES MODEL SERIES: 1600 Nailor specialty shape louvers are available in a variety of blade/frame designs. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). Contact Nailor for special configurations or requirements. Frame profile may vary depending upon louver style and shape. Other: ______________ . ❑ AN15 Clear Anodized 215-R1. Channel type standard. Performance of specialty shape louvers may vary from that of standard louvers. ENGINEER: CONTRACTOR: DATE B SERIES 11 . Color: ______________ . See applicable louver model submittal sheet for blade profile.7). inside (rear) mount (adds approximately 3/8" [10] to louver depth). Color: ______________ . Mill. H1 W W TA TB H H STANDARD CONSTRUCTION: FRAME: Type 6063-T5 extruded or formed aluminum. MINIMUM SIZE: 20" W x 16" H (508 x 406).15 . Color: ______________ . ❑ ❑ ❑ ISSS Type 304 S. PAC Perimeter Anchor Clips. ❑ AN04 Clear Anodized 204-R1. The following louver models are available in specialty shapes as shown: 1602J (SB) 1604J 1604D (SD) 1606J 1606D (SD) 1602K (SR) 1604JD (SB) 1604DD 1606JD (SB) 1606DD 1604KD (SR) 1606KD (SR) Note: Use of drainable blades is not recommended on certain shapes.3) expanded. Consult Nailor for section details of specific sizes. Previous View Home Contents Dimensions Performance Specification 1600TT . ❑ PCC Prime Coat. Type 6063-T5 extruded aluminum. High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). 1600TT-1 7 .5] Undersize standard): ❑ ❑ ❑ U00 Exact Size.S.21 . flattened aluminum bird screen in removable frame. TYPICAL CHANNEL FRAME (STANDARD) SCHEDULE TYPE: PROJECT: OPTIONAL FLANGED FRAME (FL) Dimensions are in inches (mm). Insect Screen.5). (1. reserves the right to change any information concerning product or pricing without notice. Suitable for use in exhaust and low to medium velocity intake applications. J style.S.S. incorporating J style blades. Welded Construction.0) galvanized bird screen in removable frame (adds approximately 3/8" [10 ] to louver depth). 1" (25) Filter Rack. is an architecturally styled 4" (102) deep formed louver designed with smooth. ❑ U38 Undersize 3/8" (9. ENGINEER: CONTRACTOR: DATE B SERIES 12 . Aluminum Insect Screen. 8 . Construction. the blade design features a rear water baffle and provides good protection against general weather conditions. 1 1/2" (38) BIRD SCREEN FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). Previous View Home Contents Dimensions Performance Specification 1704J .09 Nailor Industries Inc. (1. ❑ PCC Prime Coat. 18 ga. Extended Sill. Bird Screen. Type 316 S. clean lines that visually compliment any structure’s exterior styling. NO M. Larger louvers will require field assembly of smaller sections. 18 Gauge Construction.3) formed galvanized steel. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ).7). 4" (102) on centers. Type 304 S. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). MINIMUM SIZE: 12" wide x 12" high (305 x 305).10 1700 SUPERSEDES DRAWING NO. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BSA BSSS BSN ISA ISSS 18GA 16GA Flanged Frame. STANDARD CONSTRUCTION: FRAME: 4" (102) deep. Aluminum Bird Screen. Galvanized steel construction is economical. with low pressure drop characteristics and a high free area. Perimeter Anchor Clips. Color: ________________ .FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • J BLADE MODEL: 1704J NOM. Construction. OPTIONAL W x H SIZING (1/4" [6. ❑ U50 Undersize 1/2" (12. BLADES: 20 ga. SCREEN: 1/2" x 1/2" x 19 ga. BLADE SPACING: Approx. HEIGHT – 1/4" (6) STD. 2" (51) Filter Rack.5] Undersize standard): ❑ U00 Exact Size. H– 1/4 " (6 )S TD . WI DT MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438). yet durable and is available with channel or flanged frame. Color: ________________ . Model 1704J is engineered to be architecturally appealing as well as mechanically enduring.S. Color: ________________ .25 . (13 x 13 x 1. 16 Gauge Construction. FINISH: Mill. Type 304 S. BLADE ANGLE: Fixed at 45 degrees. 4" (102) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. Model 1704J. ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 316 WE ESI FR1 FR2 PAC Type 304 S.1 .0) formed galvanized steel.S. No Bird Screen. 26 0. Tested to AMCA Fig.16 1.14 17.53 9.33 13.69 0.44 7.15 60 2.62 15.28 0.79 4.59 14.22 0.0 (248.65 4.16 18.53 5.42 0.56 1.g.19 0.03 (7.37 13.40 (99.6) .73 42 1.41 6.58 36 1.40 0.46 0.08 0.20 5.71 7.42 30 1.68 0.23 0.77 0.51 1.07 1.44 0.03 1.49 0.30 (74.30 1.02 54 2.32 6.80 0.83 18.30 0.86 10. (32 Pa) NOTE: To minimize water penetration when sizing intake louvers.21 9.81 1.70 0.5-6.43 0.65 12.04 7. m) (15 min.49 1.92 1.52 12 0.55 0.43 1.47 0.5) 200 300 (61.41 10. Standard air density @ 0.33 0.53 (0.29 1.99 14.60 0.37 17.03 1.37 0.5.29 0.78 3.30 66 2.05 0.34 2.16 0.29 7.27 1.02 7.55 20.76 2.56 0.50 1.92 1.23 0.70 3.1 .41 0.14 11.75 2.56 6.11 0.14 2.53 0.83 8.22 3.08 4.77 6.60 (149.g.25 0.02 1.21 0.18 0.46 0.67 2.94 1. .12 0.27 9.91 1.13 0.60 0.94 14.34 0.11 4.06 12.57 0.01 (2.29 1.14 0.92 15.37 1.31 0.5) .62 3.79 0.63 0.22 0.83 0.59 9.) Free Area Velocity at Point of Beginning Water Penetration at .59 8.61 1.17 0.69 1.16 8.71 11. 8 .76 1.46 2.FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • J BLADE PERFORMANCE DATA MODEL: 1704J FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0.10 11.6) for 48" x 48" (1219 x 1219) Louver Size 53% 8.29 24 0.38 0.39 0.59 78 3.29 0.22 2.28 1.20 0.83 1.32 8.16 0. ft.30 0.20 (49.08 4.12 0.61 0.02 0.95 2.73 12.29 4.52 3.51 0.09 Nailor Industries Inc.30 1.13 in.32 1. (sq.49 0.0) (91.86 1.03 1. reserves the right to change any information concerning product or pricing without notice.11 0.34 0.93 5.06 1.00 3.04 1.39 8.78 0.11 1.44 0.39 3.21 0.59 8.0) .98 0.78 0.29 0.63 4.62 21.05 0.33 0.50 1.20 0. select a Free Area Velocity that is below the point of beginning water penetration.86 13.48 6.57 0.86 11.02 (5.97 11.01 16.50 4.15 1.44 7.4) .89 15.55 9.07 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).8) 2000 3000 (609.4) 1000 (304.2) .14 18 0.71 0.82 2. ft.35 10.35 0. w.28 0.01 oz.96 5.17 PRESSURE DROP AIRFLOW / WATER PENETRATION DATA 1.93 48 1.17 3.61 0.04 0.91 16.70 0.79) Static Pressure Drop in Inches w. (3 ml/sq.25 .61 0.19 6.45 0.15 10.10 0.075 lbs/ft 3 .08 0.41 1. ENGINEER: CONTRACTOR: DATE B SERIES 12 .82 2.85 1.83 6.39 6.16 0.4) 500 (152.85 1.50 0.65 0. 5./sq.24 0.91 0.09 0.97 3.52 0.11 1.40 1.07 0.39 0.05 (12.13 1.29 0.20 1.95 23.58 0.61 5.77 16.10 1700 SUPERSEDES DRAWING NO. test duration) Air Volume at 869 fpm Free Area Velocity Pressure Drop @ 869 fpm 869 fpm (265 m/min.10 (24.35 9.10 0.01 3.70 (174.67 0.90 1.61 0.3) .78 0.15 12.19 1.17 1.97 7.37 5.08 0.38 19.50 (124.56 0.86 11.40 2. Previous View Home Contents Dimensions Performance Specification 1704J .00 1. m.52 0.82 1. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).34 0.72 1.22 7.13 12.24 2.36 5.87 1.92 6.76 0.78 9.63 5.22 1.74 84 3.26 0.7) INTAKE .03 96 4.13 0.30 0.87 2.99 1.9) .46 0.10 1.20 3.) 7413 cfm (3498 l/s) .57 0.39 1.41 0. (Pa) I N T A K E Free Area % Free Area sq.56 8.76 0.50 0.72 0.16 20.0) .4) .37 0.82 0.36 0.21 1.88 90 3.08 18.58 4.81 4.91 1.68 0.44 72 3. reserves the right to change any information concerning product or pricing without notice.2 . 1/2" x 1/2" x 19 ga. with low pressure drop characteristics and a high free area.7). ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). ❑ U50 Undersize 1/2" (12. Previous View SUPERSEDES DRAWING NO.S.0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). Type 304 S. Type 316 S. OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603.S. Bird Screen.5] Undersize standard): ❑ U00 Exact Size. BIRD SCREEN FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). SCREEN: NO M. ❑ U38 Undersize 3/8" (9.09 1704JD 1704JD February. clean lines that visually compliment any structure’s exterior styling. Welded Construction. The drainable head feature utilizes a top gutter that collects the water running down the building face and channels it out the concealed downspouts in the side frame. 4" (102) MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438). Extended Sill. incorporating J style blades.S. FINISH: Mill. Color: ________________ . ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 316 WE ESI FR1 FR2 PAC Type 304 S. Perimeter Anchor Clips. HEIGHT – 1/4" (6) STD. 18 ga. STANDARD CONSTRUCTION: FRAME: 4" (102) deep. Larger louvers will require field assembly of smaller sections. WI DT H– 1/4 " (6 )S TD . Model 1704JD. 2011. Color: ________________ . Construction. MINIMUM SIZE: 12" wide x 12" high (305 x 305). Construction. (13 x 13 x 1.3) formed galvanized steel. BLADES: 20 ga.3 . 2" (51) Filter Rack. 1" (25) Filter Rack. Galvanized steel construction is economical.5). 16 Gauge Construction. BLADE ANGLE: Fixed at 45 degrees.0) formed galvanized steel. Color: ________________ . ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). Nailor Industries Inc. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BSA BSSS BSN ISA ISSS 18GA 16GA Flanged Frame.11 1700 Home Contents Dimensions 1704SB-1 6 . Aluminum Insect Screen. 1 1/2" (38) OPTIONAL W x H SIZING (1/4" [6. yet durable and is available with channel or flanged frame.FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • J BLADE • DRAINABLE HEAD MODEL: 1704JD (1704SB) NOM. J style. Aluminum Bird Screen. (1. the blade design features a rear water baffle and provides good protection against general weather conditions. Type 304 S. ENGINEER: CONTRACTOR: DATE B SERIES 2 .S. Performance Specification . ❑ PCC Prime Coat. is an architecturally styled 4" (102) deep formed louver designed with smooth. Insect Screen. BLADE SPACING: Approx. thus preventing it from flowing down into the airstream. (1. 4" (102) on centers. 18 Gauge Construction. No Bird Screen. Suitable for use in exhaust and low to medium velocity intake applications. Model 1704JD is AMCA Licensed and is engineered to be architecturally appealing as well as mechanically enduring. 20 (49.08 1.01 (2.58 0.50 0.75 0.53 15.26 1.44 10.37 1.25 5.23 0.25 0.10 (24.85 1.89 1. Nailor Industries Inc.93 3.07 1.00 1. Page 2 of 2 Dimensions are in inches (mm).03 20.29 (0.24 0. Nailor Industries Inc.68 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).63 17.16 in.5.46 1. 2011.88 1. (3 ml/sq.11 9.08 2.8) Performance Specification .91 2.87 7.13 18 0. (Pa) I N T A K E Free Area % Free Area sq.62 14.62 3.24 1.99 8.11 1700 Home Contents Dimensions SUPERSEDES DRAWING NO.48 0.13 1.14 1.54 0.4) 500 (152.53 1.29 9.79 5.99 4.52 0.19 0.23 1.12 0.70 6.58 0.70 0.05 1.29 0.46 0.35 9.63 0.08 3.22 1.49 16.55 7.45 3.42 0.16 1.11 1.48 0.61 0.02 (5.64 1.26 1.30 0.03 (7.39 1.40 72 2.20 0. certifies the Model 1704JD shown herein is licensed to bear the AMCA Seal.) Free Area Velocity at Point of Beginning Water Penetration at .4) .35 0.71 2.61 0.56 36 1.24 13.08 5.53 14.0) .07 0.07 6.27 66 2.33 6.0) (91.98 0.49 0.13 0.0 (248.76 0.99 4.33 0.62 48 1.82 7.45 1.16 0.26 0.55 78 3.40 5.52 0.75 0.39 0.40 0.01 1.3) .54 0.28 1.26 7.01 oz.01 1.23 1.81 1.68 0.11 9.80 7.96 1.55 0.01 0. Seal applies to air performance ratings and water penetration ratings.56 9.53 3.3 .99 4.30 0.98 13.36 2.57 1.44 0.24 6.37 1.5) 200 300 (61.83 90 3.18 8.99 1.14 7.40 6.82 11.64 8.03 1.38 15.94 16.52 1.27 0. (40 Pa) NOTE: To minimize water penetration when sizing intake louvers.85 5.81 5.60 (149. (sq.89 19.58 10.40 8.63 1.76 0. 1704SB-2 6 .40 8.83 1.77 1.62 15.05 13.50 (124.30 (74.04 6. ENGINEER: CONTRACTOR: DATE B SERIES 2 .62 0.44 0.71 16.43 0.99 54 2.08 1.11 0. ft.29 0.g. reserves the right to change any information concerning product or pricing without notice.24 0.10 0.82 12.77 2.55 3.25 1.07 21.48 4.14 2.89 10.66 0.34 8.20 0.17 10.17 1.58 11.65 19.16 2.02 0.08 0.24 14.07 1.32 0.70 3.44 0.22 0.32 2.84 0.22 0.g.28 24 0.84 10. ft.48 5.18 0.6) for 48" x 48" (1219 x 1219) Louver Size 52% 8.91 0.7) INTAKE .60 0.28 0.12 60 2.4) 2000 3000 (609.30 0.65 0.37 0.88 10.04 0.41 30 1.70 4.55 4.36 0.97 96 4.36 18.77) Static Pressure Drop in Inches w.05 0.06 0.27 0.67 0.08 0.39 0.53 5.40 4.07 1.27 5.11 0. Tested to AMCA Fig.70 18.25 2.56 0.67 2.02 0.62 2.70 (174.26 6.16 1.46 1.16 0./sq.17 6.78 0.75 0.36 22.2) .69 0. Previous View 1000 (304.89 0.43 0.64 5. test duration) Air Volume at 937 fpm Free Area Velocity Pressure Drop @ 937 fpm 937 fpm (286 m/min.60 13.92 3.5-6.09 0.11 PRESSURE DROP AIRFLOW / WATER PENETRATION DATA 1.33 0.59 0.4) .16 3.59 0.32 0.83 0.33 0.50 0.84 12.12 0.46 0.15 0.17 4.6) .FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • J BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1704JD (1704SB) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0. 5. m) (15 min.38 0.89 1.34 0.25 0.72 11.075 lbs/ft 3 .40 (99.68 1.39 2.04 1.71 42 1.56 0.20 0.43 11. m.37 0.91 1.38 0.09 1704JD 1704JD February.49 0.91 1.70 2.41 0.71 4. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.11 8.89 2. select a Free Area Velocity that is below the point of beginning water penetration. SCHEDULE TYPE: PROJECT: .53 13.16 0.5) .2 .52 12 0.26 7.9) .01 8.68 0.05 (12.77 0.97 1.05 0.07 0.44 0.14 0.65 1.35 8.68 2. w. Standard air density @ 0.80 1.04 9.83 0.28 0.69 84 3.76 0.35 1.0) .35 12.55 0.) 7768 cfm (3666 l/s) .75 12.22 0.13 0. Welded Construction. with low pressure drop characteristics and a high free area. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). (1. FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • J BLADE MODEL: 1706J NO M. FINISH: Mill. (1.5] Undersize standard): ❑ U00 Exact Size.S. Previous View Home Contents Dimensions Performance Specification 1706J . Larger louvers will require field assembly of smaller sections. reserves the right to change any information concerning product or pricing without notice. OPTIONAL W x H SIZING (1/4" [6. BLADE SPACING: Approx. the blade design features a rear water baffle and provides good protection against general weather conditions. Color: ________________ . SCREEN: 1/2" x 1/2" x 19 ga.5). HEIGHT – 1/4" (6) STD.S.0) formed galvanized steel. )S TD . Color: ________________ . Type 304 S. Type 304 S.25 . MINIMUM SIZE: 12" wide x 12" high (305 x 305). 2" (51) Filter Rack. is an architecturally styled 6" (152) deep formed louver designed with smooth. 18 ga. incorporating J style blades. 16 Gauge Construction. clean lines that visually compliment any structure’s exterior styling. Suitable for use in exhaust and low to medium velocity intake applications. H– 1/4 " (6 OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BSA BSSS BSN ISA ISSS 18GA 16GA Flanged Frame. Bird Screen. WI DT MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438). Color: ________________ .3) formed galvanized steel.09 Nailor Industries Inc. Construction. Insect Screen. 5 1/2" (140) on centers. ENGINEER: CONTRACTOR: DATE B SERIES 12 . Perimeter Anchor Clips. 6" (152) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. 1" (25) Filter Rack. ❑ U50 Undersize 1/2" (12. ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 316 WE ESI FR1 FR2 PAC Type 304 S. BLADES: 20 ga. Model 1706J is engineered to be architecturally appealing as well as mechanically enduring. (13 x 13 x 1.7). Aluminum Insect Screen.Model 1706J. No Bird Screen. J style.1 . ❑ U38 Undersize 3/8" (9.S. Aluminum Bird Screen. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). STANDARD CONSTRUCTION: FRAME: 6" (152) deep.S. 1 1/2" (38) BIRD SCREEN FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). Type 316 S. Construction. Extended Sill. BLADE ANGLE: Fixed at 45 degrees. Galvanized steel construction is economical. 8 .0) galvanized bird screen in removable frame (adds approximately 3/8" [10 ] to louver depth).10 1700 SUPERSEDES DRAWING NO. ❑ PCC Prime Coat. NOM. 18 Gauge Construction. yet durable and is available with channel or flanged frame. 31 1.81 4.67 1.46 8.46 0. 8 .91 90 3.56 0.30 0.04 0.28 8.42 10.52 0.24 0.4) .) 8001 cfm (3776 l/s) .40 6.50 (124.00 12.4) 500 (152.17 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).49 0.85 10.03 (7.46 0.08 2.30 0.07 0.96 3.77 6.33 7.0) (91.21 1.5) 200 300 (61.69 0. 5. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).98 0.49 0.5) .40 3.59 9. select a Free Area Velocity that is below the point of beginning water penetration.) Free Area Velocity at Point of Beginning Water Penetration at .10 1700 SUPERSEDES DRAWING NO.68 0.76 0. w.15 60 2. Previous View Home Contents Dimensions Performance Specification 1706J .76 0.28 1.91 0.05 0. (3 ml/sq.1 .40 0.01 1.56 1.70 42 1.70 (174.03 0.0) .19 0.96 5.20 0.27 0.62 0.0 (248.56 5.15 0.85 2.5.98 6.41 6.26 0.75 1.90 21.30 5.68 0.36 0.86 1.44 14.67 2.71 11.75 7.g. Standard air density @ 0.05 (12.89 10.98 6.35 2.42 0.10 4.27 6.32 0.21 AIRFLOW / WATER PENETRATION DATA PRESSURE DROP 1.40 30 1.04 7.01 oz.27 0.90 0.34 7.79 7.07 0.91 1.10 0.25 8.84 4.40 1.64 1.61 0.56 0.02 (5.15 12. reserves the right to change any information concerning product or pricing without notice.83 8.13 1. (Pa) I N T A K E Free Area % Free Area sq.44 0.39 0.89 21.28 9.92 1.0) .63 0.27 0.78 0.38 2.10 (24.39 6.61 0.02 0.33 0.86 1.76 1.89 3.50 0.79 0.83 0.08 1./sq.90 1.48 4.30 1.25 24 0.13 12.07 1.12 0.97 13.11 2.68 0.77 1.32 0.51 17.59 0.87 3.16 0.64 0.20 0.21 11.15 5.62 9.30 66 2.56 0.32 0.00 54 2.53 1.03 1.04 0.68 0.53 9.69 5.19 11.55 36 1.53 (0.77 0.12 2. ft.34 0.22 1.71 0.15 1.6) for 48" x 48" (1219 x 1219) Louver Size 53% 8.40 (99.09 15.02 0.09 0.92 1.11 1.21 5.32 8.15 in.79) Static Pressure Drop in Inches w.44 0.32 18.29 0.41 0.68 5.50 0.03 16. ft. Tested to AMCA Fig.05 15.04 4.39 0.73 0.29 0.15 2.30 (74.52 4.11 0.06 96 4.62 0.4) 1000 (304.37 0.80 0.19 0.18 0. m) (15 min.02 1.03 16.76 0.47 0.37 0.46 18.29 0.20 1.21 0.29 1.84 12.11 14.44 0.13 0.22 1.40 1.76 84 3.23 0.04 1.15 13.59 14.85 1.65 2.4) .33 0.43 20.00 1.09 Nailor Industries Inc.88 6.59 0.77 48 1.09 0.3) .27 0.38 0.06 1.71 9.075 lbs/ft 3 .74 15.43 1.71 0.65 8.61 78 3.9) .09 4.25 6.09 18 0.50 4.90 1.27 2.21 0.52 0.g.93 3.21 9.79 1.08 0.06 0.04 1.98 2.7) INTAKE .90 1.86 11.62 19.65 2.37 1.93 1.37 0.13 0.52 2.60 (149.04 1.83 2.28 1.40 5.22 0.34 0.23 10.61 0.02 7.16 1.8) 2000 3000 (609.17 1.58 0.52 12 0.2) .50 0.5-6.58 3.52 1.43 5.44 1.34 23.01 (2.25 .45 72 3.71 1.97 18.52 3.07 0.36 7.65 1.27 9.54 0.15 11.78 2. ENGINEER: CONTRACTOR: DATE B SERIES 12 .79 13.23 0.07 0.59 14. test duration) Air Volume at 938 Free Area Velocity Pressure Drop @ 938 fpm 938 fpm (286 m/min.32 1.FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • J BLADE PERFORMANCE DATA MODEL: 1706J FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0.95 1. (sq.81 0.20 (49.49 0.22 3. (37 Pa) NOTE: To minimize water penetration when sizing intake louvers.34 17.41 0.07 15.63 0. .28 0.14 0.21 16.66 4.45 0.48 0.58 1. m.22 0.15 0.53 2.6) .52 10. Color: __________ . 16GA 16 Gauge Construction. Insect Screen. Larger louvers will require field assembly of smaller sections. (13 x 13 x 1. FR1 1" (25) Filter Rack. Bird Screen. WI DT H– 1/4 " (6 )S TD . BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6. ESI Extended Sill. FINISH: Mill. (1. FR2 2" (51) Filter Rack. (1. PAC Perimeter Anchor Clips. 316 Type 316 S. J style. Color: __________ . SCREEN: NO M.5] Undersize standard): ❑ U00 Exact Size. Previous View SUPERSEDES DRAWING NO. BLADE SPACING: Approx. WE Welded Construction. MINIMUM SIZE: 12" wide x 12" high (305 x 305). BSN No Bird Screen.S. ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 Type 304 S. the blade design features a rear water baffle and provides good protection against general weather conditions. Construction. ISA Aluminum Insect Screen. ISSS Type 304 S. HEIGHT – 1/4" (6) STD. 2011.3 . Color:_________ .S. 18GA 18 Gauge Construction.0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). Nailor Industries Inc.0) formed galvanized steel. ❑ U38 Undersize 3/8" (9. OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. with low pressure drop characteristics and a high free area. ❑ U50 Undersize 1/2" (12. reserves the right to change any information concerning product or pricing without notice. is an architecturally styled 6" (152) deep formed louver designed with smooth.S.5). Suitable for use in exhaust and low to medium velocity intake applications. clean lines that visually compliment any structure’s exterior styling. Performance Specification .09 1706JD 1706JD February. STANDARD CONSTRUCTION: FRAME: 6" (152) deep. FLANGED FRAME (FL) (OPTIONAL) Page 1 of 2 Dimensions are in inches (mm). BSA Aluminum Bird Screen. Construction. 1/2" x 1/2" x 19 ga. BLADES: 20 ga. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 1 1/2" (38) (Equivalent to 70% Kynar ® ). MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438).7). BLADE ANGLE: Fixed at 45 degrees. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 6" (152) FL Flanged Frame. Galvanized steel construction is economical.3) formed galvanized steel.11 1700 Home Contents Dimensions 1706SB-1 6 . ❑ PCC Prime Coat. Model 1706JD. yet durable and is available with channel or flanged frame. incorporating J style blades. thus preventing it from flowing down into the airstream.S. SCHEDULE TYPE: PROJECT: ENGINEER: CONTRACTOR: DATE B SERIES 2 . BSSS Type 304 S. The drainable head feature utilizes a top gutter that collects the water running down the building face and channels it out the concealed downspouts in the side frame. 18 ga.2 . Model 1706JD is AMCA Licensed and is engineered to be architecturally appealing as well as mechanically enduring. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). 5 1/2" (140) on centers.FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • J BLADE • DRAINABLE HEAD MODEL: 1706JD (1706SB) NOM. 49 18.17 1.8) Performance Specification .71 84 3.81 15.77 13.18 7.01 4.43 0.06 0. Tested to AMCA Fig.71 1.58 5.91 19.39 0.61 0.56 0.12 1.05 0. reserves the right to change any information concerning product or pricing without notice.98 8.53 1.54 0.52 0.26 0.86 17.52 12 0.24 6.33 5.75 1.79 0.3) .31 2.45 2.59 0.68 42 1.29 5.11 1700 Home Contents Dimensions SUPERSEDES DRAWING NO.83 0.09 13. Nailor Industries Inc. (Pa) I N T A K E Free Area % Free Area sq.83 10.30 3.91 17.07 8.87 6.03 5.32 0.21 1.5) 200 300 (61.69 0. Seal applies to air performance ratings and water penetration ratings.36 1.97 1.10 0.9) .83 1.10 (24.77 0.33 21.31 0.95 10.09 18 0.5-6.47 0.24 13.19 0.15 AIRFLOW / WATER PENETRATION DATA PRESSURE DROP 1.39 1. certifies the Model 1706JD shown herein is licensed to bear the AMCA Seal.) Free Area Velocity at Point of Beginning Water Penetration at .28 10.12 19.31 2.01 1.19 in.25 6.30 0.47 48 1.07 0.18 1.40 1.83 0.82 12.77 0.90 11.4) .36 0.87 0.23 0.93 2.40 4.42 4.15 5.05 1.08 0.45 3.40 1.97 54 2.05 0. m) (15 min.35 15.95 4.87 7.30 0. (3 ml/sq.07 0.15 0.72 11.98 1.37 0.73 0.19 0.60 2.69 0.37 1.07 8.77) Static Pressure Drop in Inches w.58 10.5) .80 2.98 0.00 96 4.24 24 0.02 (5.25 0.38 3.08 1. 1706SB-2 6 .59 1.89 1. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.57 0.84 12.18 0.06 2.79 3.11 0.57 0.61 0.17 0. Nailor Industries Inc.22 0.37 1.40 (99.76 0.29 9.10 6.27 1.04 0. (47 Pa) NOTE: To minimize water penetration when sizing intake louvers.15 6.) 8530 cfm (4025 l/s) .075 lbs/ft 3 .73 4.44 0.57 0.40 0.47 0.55 0.04 9.49 0. Page 2 of 2 Dimensions are in inches (mm).97 4.40 0.89 1.12 60 2.14 0.01 (2.60 (149.31 0.25 1.4) .02 2.56 78 3. 2011.5.01 oz.4) 500 (152.78 2.2 .99 0.76 0.0 (248.75 0.32 0.62 0.99 1.21 2.74 6.19 0.15 0.35 9.05 (12.74 0.68 0.84 12.02 0.37 0.92 1.72 14.66 1.12 0.62 2.61 16.07 0.17 0.27 0. ft.29 (0.28 0.74 23.85 5.49 1.37 20./sq.06 5.27 0.03 0.95 2.11 2.61 0.g.70 14.31 0.31 0.71 0.41 8.09 0. Previous View 1000 (304.0) (91.27 66 2.33 0.88 1. SCHEDULE TYPE: PROJECT: . select a Free Area Velocity that is below the point of beginning water penetration.15 0. ENGINEER: CONTRACTOR: DATE B SERIES 2 .91 0.39 30 1.07 1.25 8.63 16.18 7.38 0.89 11.05 2.16 3.56 4.15 0.31 5.56 5.49 12.89 0.07 16.6) . Standard air density @ 0.2) .4) 2000 3000 (609.3 .7) INTAKE .70 (174.FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • J BLADE • DRAINABLE HEAD PERFORMANCE DATA MODEL: 1706JD (1706SB) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0.24 1.79 1.73 0.64 5.22 1.03 (7.56 7.44 0.6) for 48" x 48" (1219 x 1219) Louver Size 52% 8.48 0.54 0.60 0. (sq.46 0.53 12.50 (124.49 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).09 1706JD 1706JD February.85 90 3. 5.0) .04 0.40 0.91 1.18 9.48 0.97 10.14 1.90 1.51 3.03 1.81 6.53 36 1.13 0.81 3.60 2.18 1.20 0.46 8.61 0.52 0.01 1.76 0.07 0.66 0.83 1.52 8.66 0.11 8. ft.27 1.26 0.00 18.65 15.46 0.20 0.48 0.05 1.41 72 3.23 0.33 0.g.63 7.67 9.07 7.46 0.28 1.88 2.42 0.64 8.52 1.28 0.66 0.63 13.01 1.09 1.44 10.67 0. test duration) Air Volume at 1029 Free Area Velocity Pressure Drop @ 1029 fpm 1029 fpm (314 m/min.0) .35 0.21 0.37 0.16 7.53 2.12 0.88 3.85 7.23 0. m.20 (49.30 (74.30 5.36 0.73 4.78 0.29 0.47 1.63 1.26 13. w. Construction. 1" (25) Filter Rack. )S TD . Larger louvers will require field assembly of smaller sections. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). 2" (51) Filter Rack. 20 ga. yet durable and the design provides good air performance through it’s 53% free area as well as excellent protection against the elements. NO M. Model 1704D is available with channel or flanged type frame to suit most architectural and mechanical installation requirements. STANDARD CONSTRUCTION: FRAME: 4" (102) deep. Aluminum Insect Screen. (1. (1. OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. 18 Gauge Construction.S. Galvanized steel construction is economical. 1 1/2" (38) BIRD SCREEN FLANGED FRAME (FL) (OPTIONAL) Page 1 of 2 Dimensions are in inches (mm). Color: ________________ . Type 304 S.S. Color: ________________ . Extended Sill.5] Undersize standard): ❑ U00 Exact Size.0) formed galvanized steel. drainable blade type formed louver. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). with good air performance and pleasing aesthetics that compliment any structure’s exterior styling. WI DT H– 1/4 " (6 MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438). 16 Gauge Construction.10 1700 SUPERSEDES DRAWING NO. Type 304 S.0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). Aluminum Bird Screen. Drainable style. No Bird Screen. ❑ PCC Prime Coat. 1704SD-1 7 . Insect Screen. Perimeter Anchor Clips. Construction. Model 1704D. FINISH: Mill.27 .5). reserves the right to change any information concerning product or pricing without notice.7). Suitable for use in exhaust and low to medium velocity intake applications. HEIGHT – 1/4" (6) STD. (13 x 13 x 1.0) formed galvanized steel. 4" (102) on centers. Welded Construction. MINIMUM SIZE: 12" wide x 12" high (305 x 305). OPTIONAL W x H SIZING (1/4" [6.FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • DRAINABLE BLADE MODEL: 1704D (1704SD) NOM. ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 316 WE ESI FR1 FR2 PAC Type 304 S. provides excellent weather protection in a 4" (102) deep frame. SCHEDULE TYPE: PROJECT: ENGINEER: CONTRACTOR: DATE B SERIES 12 . 4" (102) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BSA BSSS BSN ISA ISSS 18GA 16GA Flanged Frame. Color: ________________ . Type 316 S.09 Nailor Industries Inc. the drainable blade design utilizes rain gutters that divert collected water down concealed side downspouts and out the sill. ❑ U38 Undersize 3/8" (9. SCREEN: 1/2" x 1/2" x 19 ga. Bird Screen. BLADES: 20 ga. Previous View Home Contents Dimensions Performance Specification 1704D . BLADE ANGLE: Fixed at 45 degrees.1 . BLADE SPACING: Approx. ❑ U50 Undersize 1/2" (12.S.S. 22 0.69 84 3.30 (74.22 0.63 17.56 0.44 10.26 0.50 0.25 0.24 0.35 0.53 5.20 0.3) .75 12.94 16.97 96 4.23 1. test duration) Air Volume at 976 fpm Free Area Velocity Pressure Drop @ 976 fpm 1.23 0. ft.06 0.26 6.70 3.26 7.24 6.58 0.81 1.37 1.) 8237 cfm (3887 l/s) .26 1.5-6.39 0.99 1.84 0. ft.82 12.75 0. select a Free Area Velocity that is below the point of beginning water penetration.0) .53 3.72 11.05 (12.25 2.09 Nailor Industries Inc.28 0.55 78 3.33 0.93 3.53 14.70 2.12 0.23 1.53 1.70 (174.01 1.00 1.02 (5.61 0.58 0.32 0.62 14.68 0.09 0.28 0. Page 2 of 2 Dimensions are in inches (mm).4) .13 1.56 36 1.07 1.13 18 0.70 6.1 .76 0.39 2.25 5.58 10.63 0.11 9.08 1.33 0.83 0.32 2.27 .14 7.65 1.35 12.46 0.48 5. 5.52 12 0.82 7.50 (124.56 0.91 1.16 1.05 0.52 0.68 2.39 1.89 0.08 2.88 1.17 4.71 2.44 0.16 2.30 0.91 0.25 1.16 1.17 6.08 0.43 0.37 1.44 0.17 10.99 54 2. Previous View Home Contents Dimensions Performance Specification 1704D .33 6.44 0.5.36 22.78) Static Pressure Drop in Inches w.27 0.55 0.13 0.32 0.075 lbs/ft 3 .89 19.0 (248.60 13.9) . (Pa) I N T A K E Free Area % Free Area sq.91 1.64 5.54 0.05 13.43 11.40 8.40 8.39 0.99 4.83 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).24 14. m) (15 min.04 9.80 7.44 0.53 13.FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1704D (1704SD) FREE AREA in Square Feet and Square Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0.02 0.71 16.75 0.58 11.01 1.89 1. (35 Pa) NOTE: To minimize water penetration when sizing intake louvers.30 0.84 12.98 0.87 7.08 0.89 1.77 1.07 21.18 0.46 0.62 0.62 2.12 60 2. SCHEDULE TYPE: PROJECT: ENGINEER: CONTRACTOR: DATE B SERIES 12 .4) 1000 (304.28 1.8) 2000 3000 (609.19 0.55 4.01 0.46 1.29 0.40 6.49 0.98 13.65 19.85 5.16 0.27 5.55 7. m.27 66 2.70 18.24 0.22 1.82 11.45 3.57 1.0) (91.37 0.44 (0.40 (99.37 0.03 20.11 1.49 16.16 0.71 4.54 0.62 48 1.96 1.11 8.01 oz.34 0.36 2.17 1.70 4.7) INTAKE .50 0./sq.97 1.07 0.0) . . (sq.01 8.20 0.85 1.52 1.68 0.89 10.35 1.04 0.62 3.62 15.22 0.71 42 1.83 1.27 0.10 (24.11 0.40 4.68 0.38 0.05 0. 1704SD-2 7 . Tested to AMCA Fig.42 0.61 0. Standard air density @ 0.99 4.g.11 9.40 5.48 4.6) 976 fpm (297 m/min.60 (149.03 (7.07 1.59 0.11 0.5) 200 300 (61.44 9.67 0.60 0.91 2.02 0.12 0.) Free Area Velocity at Point of Beginning Water Penetration at .26 1.08 1.25 0.76 0.77 2.08 5.08 3.63 1.48 0.99 4.03 1.05 1.55 0.40 0.89 2.81 5.01 (2.g. reserves the right to change any information concerning product or pricing without notice.70 0. (3 ml/sq.55 3.24 1.34 8.07 1.35 9.80 1.92 3.56 9.28 24 0.14 1.15 0.99 8.10 1700 SUPERSEDES DRAWING NO.48 0.46 1.36 0.76 0.38 0.88 10.16 0.10 0.26 7.38 15.14 2.36 18.18 8.04 1.78 0.2) .6) .29 0.4) 500 (152. w.64 8.33 0.14 in.69 0.67 2.20 (49.45 1.49 0.53 15.35 8.14 0.11 AIRFLOW / WATER PENETRATION DATA PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 53% 8.43 0.59 0.79 5.83 90 3.41 30 1.64 1.4) .68 1.52 0.04 6.65 0.07 0.07 6.30 0.5) .16 3.84 10.24 13.75 0.13 0.20 0.78 0.41 0.40 72 2.66 0. high performance drainable blade type formed steel louver. 20 ga. NO M. ❑ PCC Prime Coat. (13 x 13 x 1. MINIMUM SIZE: 12" wide x 12" high (305 x 305).10 1700 SUPERSEDES DRAWING NO. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BSA BSSS BSN ISA ISSS 18GA 16GA Flanged Frame. Model 1704DHP. Model 1704DHP is available with channel or flanged type frame to suit most architectural and mechanical installation requirements.FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • DRAINABLE BLADE HIGH PERFORMANCE MODEL: 1704DHP (1704SDHP) NOM. 3 1/2" (89) on centers. BLADE SPACING: Approx. Welded Construction. WI DT H– 1/4 " (6 )S TD . Color: ________________ . ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). Type 316 S.S. ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 316 WE ESI FR1 FR2 PAC Type 304 S. Construction. 16 Gauge Construction. SCREEN: 1/2" x 1/2" x 19 ga. ENGINEER: CONTRACTOR: DATE B SERIES 12 .5 degrees. Insect Screen.7). Type 304 S. Suitable for use in exhaust and low to medium velocity intake applications. STANDARD CONSTRUCTION: FRAME: 4" (102) deep.5). 1704SDHP-1 11 .0) formed galvanized steel. No Bird Screen. Color: ________________ .0) formed galvanized steel. Drainable style.S. yet durable and the design provides excellent air performance at higher velocities through it’s 53% free area as well as maximum protection against the elements. ❑ U50 Undersize 1/2" (12.S. (1. HEIGHT – 1/4" (6) STD. 2" (51) Filter Rack.5] Undersize standard): 1 1/2" (38) ❑ U00 Exact Size. Type 304 S. Galvanized steel construction is economical. BIRD SCREEN FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). with superior air performance and pleasing aesthetics that compliment any structure’s exterior styling.1 . BLADES: 20 ga. Perimeter Anchor Clips. reserves the right to change any information concerning product or pricing without notice. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438). Aluminum Insect Screen. 4" (102) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. the drainable blade design utilizes rain gutters that divert collected water down concealed side downspouts and out the sill.16 . Previous View Home Contents Dimensions Performance Specification 1704DHP . Bird Screen. 18 Gauge Construction. BLADE ANGLE: Fixed at 37. FINISH: Mill. Aluminum Bird Screen. Construction. 1" (25) Filter Rack. (1. Color: ________________ . Larger louvers will require field assembly of smaller sections. ❑ U38 Undersize 3/8" (9. OPTIONAL W x H SIZING (1/4" [6. Extended Sill.0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). provides excellent weather protection in a 4" (102) deep frame.S.09 Nailor Industries Inc. 83 0.02 6.33 1.88 4.17 0.08 0.90 13.29 6.37 0.37 9.03 10.40 12.20 (49.79 6.74 42 1.48 0.46 12.83 1.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).65 1.4) .02 15.41 2. 5.71 0.93 4.41 1.20 1.08 22.22 0.48 72 3.72 0.29 13.14 1.82 2.07 5.44 1.31 0.12 7.19 1.60 (149.38 0.66 14.40 0.68 0.08 1.64 4.g.23 1.44 23.66 0.60 1.1 . w.34 66 2.29 7.64 78 3.40 (99.30 24 0.11 0.79 8.16 1.05 1.97 1.04 0. m.10 (24.05 (12./sq.85 1.50 (124.5.25 0.28 0.15 4. ft.70 7.91 1.08 96 4.91 3.06 0.) 7661 cfm (3615 l/s) .26 15.4) .01 oz.91 1.07 1.23 2.15 0.4) 1000 (304.94 1.43 2.09 16.13 0.63 0. ENGINEER: CONTRACTOR: DATE B SERIES 12 .21 0.76) Static Pressure Drop in Inches w.40 0.30 0.04 54 2.68 0.71 0.13 1.41 1.87 1.34 0.06 1.73 3.46 5.61 0. m) (15 min.18 0.01 3.23 0.35 0.61 0.06 3.72 4.76 0. select a Free Area Velocity that is below the point of beginning water penetration.02 12.075 lbs/ft 3 .58 0.14 0.32 0.8) 2000 3000 (609.95 1.13 0.99 2.64 14.89 3.76 1.9) .59 0.92 1.21 14.59 10.54 18.61 8.52 0.80 0.98 6.26 11.39 1.22 1.44 0.71 0.71 5.66 0.93 1.14 7.61 0.04 1.18 0.54 1.12 0.07 0.74 1.40 7.96 0.27 0.76 0.89 1.22 PRESSURE DROP AIRFLOW / WATER PENETRATION DATA 1.35 0.86 4.45 16.20 60 2.5-6.5) .10 1700 SUPERSEDES DRAWING NO.47 1.99 21.93 10.93 1.23 1.56 2.60 36 1.0) (91.79 20.29 0.24 0.16 18 0.51 0.02 (5.54 0.37 0.19 19.50 0.74 2.79 0.78 84 3.15 1.55 10.83 17.0) .76 9.59 0.74 9.49 17.87 1.19 0.54 1.29 0.30 0.49 6.55 (0. .91 0.6) .96 6.31 8.31 1.80 1.53 0. reserves the right to change any information concerning product or pricing without notice.68 9. 1704SDHP-2 11 .19 11.22 0.g.75 0.48 3.01 (2.29 15.) Free Area Velocity at Point of Beginning Water Penetration at .69 8.17 4. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).38 2. Standard air density @ 0.98 11.18 1. (3 ml/sq.90 11.35 0.41 0.87 2.08 1.31 14.83 0.58 0.0) .46 0.72 0.13 0.30 5.87 2.61 10.59 18.37 1. Previous View Home Contents Dimensions Performance Specification 1704DHP .71 6.29 0.89 8.24 1.14 in.0 (248.79 0.75 5.30 1.69 5.36 0.20 15.22 0.74 8.50 9.2) . Tested to AMCA Fig.73 20.91 1.51 0.FORMED STEEL STATIONARY LOUVER 4" (102) DEEP • DRAINABLE BLADE HIGH PERFORMANCE PERFORMANCE DATA MODEL: 1704DHP (1704SDHP) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0.58 12. (35 Pa) NOTE: To minimize water penetration when sizing intake louvers.51 6.14 3.24 0.19 48 2.81 0.59 4.57 0.55 0.45 0.52 0.03 (7.4) 500 (152.01 1.46 30 1.89 2.41 0.09 0.45 6.90 2.44 5.94 14.62 0. (Pa) I N T A K E Free Area % Free Area sq.36 0.32 0.70 (174.33 11.42 3. test duration) Air Volume at 896 fpm Free Area Velocity Pressure Drop @ 896 fpm 896 fpm (273 m/min.16 0.27 0.03 0.80 4.3) .43 4.16 . (sq.30 (74.01 1.94 90 4.02 1.34 1.46 0.42 0.63 0.90 2.6) for 48" x 48" (1219 x 1219) Louver Size 53% 8.29 0.17 12.44 0.22 0.44 0.39 11.98 0.05 0.57 1.46 0.65 0.09 Nailor Industries Inc.54 7.11 0.7) INTAKE .48 0.46 0.54 1.94 0.64 1.22 17.02 8.27 0.5) 200 300 (61.60 7.13 5.24 3.08 0.36 1.32 3.52 12 0.13 0. ft.21 0.08 0.32 7.68 1. ❑ PCC Prime Coat. yet durable and the design provides good air performance through it’s 50% free area as well as excellent protection against the elements. Larger louvers will require field assembly of smaller sections.2 . (13 x 13 x 1. SCHEDULE TYPE: PROJECT: ENGINEER: CONTRACTOR: DATE B SERIES 2 . No Bird Screen.09 1706D 1706D February. WI DT H– MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438). 18 Gauge Construction. ❑ U50 Undersize 1/2" (12. Insect Screen. 5 1/2" (140) on centers. provides excellent weather protection in a 6" (152) deep frame. ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 316 WE ESI FR1 FR2 PAC Type 304 S.S. Color: ________________ . 1 1/2" (38) OPTIONAL W x H SIZING (1/4" [6. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). drainable blade type formed louver.5). (1. 6" (152) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603.3 . Construction. 2" (51) Filter Rack. Galvanized steel construction is economical. BIRD SCREEN FLANGED FRAME (FL) (OPTIONAL) Page 1 of 2 Dimensions are in inches (mm). Suitable for use in exhaust and low to medium velocity intake applications. Model 1706D. Aluminum Bird Screen. BLADE SPACING: Approx. Color: ________________ . Extended Sill. Type 316 S. FINISH: Mill. 1/4 " (6 )S TD . Type 304 S. Type 304 S. 2011. with good air performance and pleasing aesthetics that compliment any structure’s exterior styling. HEIGHT – 1/4" (6) STD.11 1700 Home Contents Dimensions 1706SD-1 6 . NO M. MINIMUM SIZE: 12" wide x 12" high (305 x 305).0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). the drainable blade design utilizes rain gutters that divert collected water down concealed side downspouts and out the sill.S. STANDARD CONSTRUCTION: FRAME: 6" (152) deep.S. BLADE ANGLE: Fixed at 45 degrees. Performance Specification .0) formed galvanized steel. 16 Gauge Construction. Nailor Industries Inc. Model 1706D is available with channel or flanged type frame to suit most architectural and mechanical installation requirements and is AMCA Licensed. Welded Construction.5] Undersize standard): ❑ U00 Exact Size.3) formed galvanized steel.FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • DRAINABLE BLADE MODEL: 1706D (1706SD) NOM.S. Construction. SCREEN: 1/2" x 1/2" x 19 ga. (1. Previous View SUPERSEDES DRAWING NO. 18 ga. BLADES: 20 ga.7). Bird Screen. Aluminum Insect Screen. 1" (25) Filter Rack. Drainable style. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BSA BSSS BSN ISA ISSS 18GA 16GA Flanged Frame. Color: ________________ . reserves the right to change any information concerning product or pricing without notice. Perimeter Anchor Clips. ❑ U38 Undersize 3/8" (9. 97 10.09 1706D 1706D February.63 1. ft.33 0.30 3.05 0. Page 2 of 2 Dimensions are in inches (mm).4) .9) .64 8.39 1.43 0.84 12.48 0.66 0.27 66 2.83 0.47 0.39 30 1.91 0.4) 500 (152.15 0. 1706SD-2 6 .12 19.05 (12.53 36 1.90 11.98 0.03 (7.15 PRESSURE DROP AIRFLOW / WATER PENETRATION DATA 1.32 0.6) for 48" x 48" (1219 x 1219) Louver Size 50% 8.50 (124.54 0.70 (174.56 7.36 0.01 1.20 0.07 8.91 17.07 16.57 0.01 (2.5.81 15.85 90 3.89 0.01 1.32 0.01 oz.21 1.11 8.61 0.37 1.15 0.40 1.36 1.40 0.22 0.0) .73 4.40 (99.73 4.77 0. Seal applies to air performance ratings and water penetration ratings.10 (24.33 21.75) Static Pressure Drop in Inches w.11 2.56 0.40 0.05 9.2 .FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1706D (1706SD) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0. reserves the right to change any information concerning product or pricing without notice.28 1.89 1.48 0.95 10.89 11.77 13.41 72 3.47 0.07 8.23 0.15 0.03 1.31 0.05 1.66 1.46 8.75 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).81 6.27 1.85 7.38 3.3 .28 0. SCHEDULE TYPE: PROJECT: .31 0.97 1.87 6.61 0.21 0.07 0.20 (49.85 5.56 78 3.15 6.97 54 2.52 0.65 15.54 0. Standard air density @ 0.40 4.05 1.31 5.49 18.74 23.07 1.16 3.37 0.60 2.17 0.02 0.63 16.03 0.98 1.90 1.26 13.g.89 1.87 0.47 48 1.78 2.71 1. Nailor Industries Inc.10 6.g.79 1.28 0.14 0. Tested to AMCA Fig.21 2.13 0.5-6.56 4.78 0.05 (0.67 9.36 0.30 0.83 1. (30 Pa) NOTE: To minimize water penetration when sizing intake louvers. Previous View 1000 (304.18 7.44 10.72 14.59 1.48 0.71 84 3. (3 ml/sq.04 9. test duration) Air Volume at 847 fpm Free Area Velocity Pressure Drop @ 847 fpm 847 fpm (258 m/min.08 0.38 0.30 (74.19 0. ENGINEER: CONTRACTOR: DATE B SERIES 2 .18 7.29 0.0) (91.37 0.74 0.49 0.08 1.57 0.37 1.09 18 0.11 0.59 0.05 0. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program.76 0.0 (248.51 3.14 1. w.67 0.24 1.09 0.26 0.84 12.8) Performance Specification .88 2.53 2.12 60 2.79 0.95 4.49 12.31 2.18 9.46 0.00 18.49 1. Nailor Industries Inc.33 0.04 0.71 0.33 5.02 2.68 42 1.95 2. m.5) 200 300 (61.76 0.58 10. 5.66 0.92 1.04 0.31 0.63 7.17 1.56 5.07 0.80 2.97 4.18 1.82 12.0) .29 5.58 5.) Free Area Velocity at Point of Beginning Water Penetration at .55 0.61 0.12 1.05 2.44 0.07 7.31 0.64 5.02 (5.93 2. 2011.09 13. certifies the Model 1706D shown herein is licensed to bear the AMCA Seal.18 0.31 2. select a Free Area Velocity that is below the point of beginning water penetration.52 8.52 0.12 0.40 0.83 1.61 0.27 0.18 1.73 0.24 24 0.35 15.) 6818 cfm (3217 l/s) .20 0.91 1.68 0.17 0.69 0.00 96 4.60 2.6) .72 11.62 2.87 7. ft.75 0.07 0.76 0.52 12 0.99 0.74 6.01 1./sq.06 2.4) 2000 3000 (609.49 0.24 13.52 1.12 in.62 0.23 0.30 0.88 1.81 3.06 0.35 9.88 3.45 2.16 7.23 0.06 5.79 3.60 (149.83 10.25 6.09 1.57 0.10 0.99 1.07 0.60 0.47 1.3) .11 1700 Home Contents Dimensions SUPERSEDES DRAWING NO.70 14. (sq.73 0.35 0.12 0.24 6.27 1.2) .15 0.46 0.26 0.61 16.45 3.53 1. m) (15 min.37 0.5) .39 0.25 8.98 8.41 8.44 0.30 5.66 0.15 5.19 0.53 12.03 5.91 19.01 4.25 0.22 1.46 0.27 0.63 13. (Pa) I N T A K E Free Area % Free Area sq.69 0.42 0.40 1.4) .25 1.83 0.75 1.37 20.42 4.19 0.7) INTAKE .075 lbs/ft 3 .86 17.28 10. Color: ________________ . STANDARD CONSTRUCTION: FRAME: 6" (152) deep.7). Drainable style. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ).0) formed galvanized steel. (1. Previous View Home Contents Dimensions Performance Specification 1706DHP . ❑ PCC Prime Coat. Aluminum Insect Screen. 1706SDHP-1 11 . FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). Extended Sill. MAXIMUM SINGLE SECTION SIZE: 60" wide x 96" high (1524 x 2438). BLADE ANGLE: Fixed at 37. Construction. (1. (13 x 13 x 1. 6" (152) OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. yet durable and the design provides excellent air performance at higher velocities through it’s 56% free area as well as maximum protection against the elements.0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). Type 304 S. the drainable blade design utilizes rain gutters that divert collected water down concealed side downspouts and out the sill. NOM.S. ENGINEER: CONTRACTOR: DATE B SERIES 12 . Type 304 S. MINIMUM SIZE: 12" wide x 12" high (305 x 305).09 Nailor Industries Inc. Model 1706DHP is available with channel or flanged type frame to suit most architectural and mechanical installation requirements. Type 316 S. No Bird Screen.Model 1706DHP. reserves the right to change any information concerning product or pricing without notice. Galvanized steel construction is economical.5 degrees. 4 1/2" (114) on centers.1 .S. BLADES: 20 ga.S. Suitable for use in exhaust and low to medium velocity intake applications. Aluminum Bird Screen. Color: ________________ . ❑ ❑ ❑ ❑ ❑ ❑ ❑ 304 316 WE ESI FR1 FR2 PAC Type 304 S.16 . Insect Screen. HEIGHT – 1/4" (6) STD. 18 Gauge Construction. OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BSA BSSS BSN ISA ISSS 18GA 16GA Flanged Frame.0) formed galvanized steel. NO M. with superior air performance and pleasing aesthetics that compliment any structure’s exterior styling. 20 ga. 2" (51) Filter Rack. ❑ U38 Undersize 3/8" (9. Color: ________________ . FINISH: Mill. Larger louvers will require field assembly of smaller sections.5] Undersize standard): ❑ U00 Exact Size. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 1 1/2" (38) (Equivalent to 70% Kynar ® ). FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • DRAINABLE BLADE HIGH PERFORMANCE MODEL: 1706DHP (1706SDHP) BLADE SPACING: Approx. Bird Screen. WI DT H– 1/4 " (6 )S TD . 16 Gauge Construction. 1" (25) Filter Rack. Perimeter Anchor Clips. Welded Construction. provides excellent weather protection in a 6" (152) deep frame. Construction.10 1700 SUPERSEDES DRAWING NO. SCREEN: 1/2" x 1/2" x 19 ga. BIRD SCREEN OPTIONAL W x H SIZING (1/4" [6.S. ❑ U50 Undersize 1/2" (12. high performance drainable blade type formed steel louver.5). 02 9.37 0.23 0.67 0.26 0.81 8.5) .23 1.19 0.76 0.82 0.8) 2000 3000 (609.08 1.53 72 3.47 0.65 0. (40 Pa) NOTE: To minimize water penetration when sizing intake louvers.74 12.17 1. .27 24 0.18 4.09 Nailor Industries Inc.68 17.65 6.27 0.4) .94 0.60 0.6) for 48" x 48" (1219 x 1219) Louver Size 56% 9.53 0.96 4.21 60 2.59 0.4) .07 2.16 0.84 9.98 0.52 6.59 0.39 0.83 1.23 11.16 in.34 3.03 10.65 0.40 (99.08 0.34 2.17 12.87 10.48 0.68 5.64 2.75 3.89 1.12 0.83 0.17 5.83 84 3.37 11.87 2.58 1.89 8.09 1.46 1. 5.22 0. Standard air density @ 0.62 0.23 3.34 1.38 2. (3 ml/sq.61 10.68 7.74 13.01 (2. (sq.g.14 1.68 0.14 0.70 4.94 1.09 1.20 4.75 42 1.77 0.67 17.43 0.51 0.20 (49.05 0.03 (7.71 1. m) (15 min.59 18.7) INTAKE .16 .84 0.05 1.81 0.64 1.26 0.71 10. (Pa) I N T A K E Free Area % Free Area sq./sq.39 0. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).61 0.78 5.11 0.30 (74. reserves the right to change any information concerning product or pricing without notice.08 0.82 2.52 0.13 0.57 12.81 9.85 5.12 14.71 13.69 78 3.41 0.84 0.13 18 0.44 0.99 90 4.27 2.11 0.19 0.06 0.37 66 2.38 1.49 1.29 0.68 7. select a Free Area Velocity that is below the point of beginning water penetration.80 16.43 1.43 30 1.27 8.10 (24.31 AIRFLOW / WATER PENETRATION DATA PRESSURE DROP 1.61 11.21 0.33 48 2.15 1.84 0.76 0.79 2.12 0.2) .09 0.35 0.61 14.02 6.39 0.60 1.56 7.13 0.5-6.37 1.79 20.63 0.03 10.56 0.84 2.79 1.34 8.46 0.37 1.40 0.43 0.16 0.05 1.22 0.17 0.35 0.02 (5.78 4.44 0.21 1.28 1.88 2.77 3.65 4.50 (124.45 16.48 3.79 6.05 (0.13 5.4) 500 (152.14 3.82 1.28 3.02 0.075 lbs/ft 3 .16 6.0) . ENGINEER: CONTRACTOR: DATE B SERIES 12 .33 0.80 7.47 0.36 7.3) .91 11.26 0.25 0.68 0.25 0.65 15.22 0.84 1.63 13.84) Static Pressure Drop in Inches w. ft.05 (12.70 19. Previous View Home Contents Dimensions Performance Specification 1706DHP .33 24. Tested to AMCA Fig.11 14.17 0.14 7.06 1.4) 1000 (304.07 1.1 .0) (91.07 0.44 0. 1706SDHP-2 11 .17 1.21 0.22 1.20 15.29 0.78 22.75 0.73 0.90 13.45 0.17 1.61 0.76 2.0) .52 12 0.13 1.91 0.36 1.30 0.34 0.73 2.59 36 1.03 3.g. ft.20 8.08 22.52 0.66 0.45 2.10 0.48 16.49 1.03 2.95 4.05 0.36 0.30 0.34 18.FORMED STEEL STATIONARY LOUVER 6" (152) DEEP • DRAINABLE BLADE HIGH PERFORMANCE PERFORMANCE DATA MODEL: 1706DHP (1706SDHP) FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 18 24 30 36 42 48 54 60 0.00 1.6) .) Free Area Velocity at Point of Beginning Water Penetration at .55 0.52 0.00 8.54 0.41 0.73 0.5) 200 300 (61.30 0.83 1.0 (248.97 1.61 0.80 4.91 1.10 1700 SUPERSEDES DRAWING NO.52 1.44 7. test duration) Air Volume at 988 fpm Free Area Velocity Pressure Drop @ 988 fpm 988 fpm (301 m/min.13 1.29 0.31 1.61 6.01 oz.77 1.22 1.90 1. w.08 0.79 6.12 3.82 1.49 17.23 19.5.89 1.40 0.37 0.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).93 2.30 0.53 0.36 5.54 5.46 5.99 1.04 0.98 1.70 0.47 7.27 1.) 8941 cfm (4219 l/s) .05 54 2. m.26 14.70 9.42 13.72 0.11 0.95 1.05 10.30 0.31 8.60 (149.31 14.78 5.15 96 4.9) .58 9.73 11.46 0.34 0.70 (174.72 1.27 1.03 9.27 5.53 0.70 0.73 20. 16 ga. OPERATOR: Hand locking louver quadrant. BEARINGS: 1/2" (13) dia. Type 304 S. Rugged galvanized steel construction provides excellent durability. Color: ________________ . No Bird Screen. FR2 2" (51) Filter Rack. WE Welded Construction. Concealed in frame.S. JAMB SEALS: Compression type cambered metal. ESI Extended Sill. the design features a drainable blade with rain gutters that divert collected water down concealed side downspouts and out the sill.FORMED STEEL ADJUSTABLE LOUVER 4" (102) DEEP • DRAINABLE BLADE MODEL: 1704AD NOM. 60" wide x 96" high (1524 x 2438) without seals. Model 1704AD adjustable. ❑ U38 Undersize 3/8" (9. 16 ga. (13 x 13 x 1. OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. FINISH: Mill. drainable blade louver combines architecturally pleasing aesthetics with airflow control including tight shut-off. FR1 1" (25) Filter Rack. 4" (102) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BPV JSN BSA BSSS BSN ISA ISSS 304 Flanged Frame. No Jamb Seals. 5 . Insect Screen. LINKAGE: Plated steel. Previous View Home Contents Dimensions Performance Specification 1704AD .6) formed galvanized steel at 37 1/2 degree angle. Larger louvers will require field assembly of smaller sections. HEIGHT – 1/4" (6) STD.1 .10 Nailor Industries Inc. OPTIONAL W x H SIZING (1/4" [6. Suitable for use in exhaust and low to medium velocity intake applications.S. ❑ PC4 High Performance Powder Coat AAMA 2604 1 1/2" (38) (Equivalent to 50% Kynar ® ). The blades can be operated manually or with an actuator to provide tight shut-off when desired. ACT Electric or Pneumatic Actuator.S. (1. Construction.3 . Type 304 S. NO M. ❑ U50 Undersize 1/2" (12. ❑ Other: _______________ . BIRD SCREEN ❑ PCC Prime Coat.0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). ENGINEER: CONTRACTOR: DATE B SERIES 12 .6) formed galvanized steel. Model 1704AD provides operable flexibility as well as excellent protection against the elements. PAC Perimeter Anchor Clips. SCREEN: 1/2" x 1/2" x 19 ga. Construction. Aluminum Insect Screen. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). STANDARD CONSTRUCTION: FRAME: BLADES: 4" (102) deep. Bird Screen. MAXIMUM SINGLE SECTION SIZE: 48" wide x 96" high (1219 x 2438) with jamb and/or blade seals.S. MINIMUM SIZE: 12" wide x 12" high (305 x 305). plated steel. reserves the right to change any information concerning product or pricing without notice. (1. Color: ________________ . stainless steel sleeve type. 3 1/2" (89) on centers.10 1700 SUPERSEDES DRAWING NO. WI DT H– 1/4 " (6 )S TD . ❑ ❑ ❑ ❑ ❑ ❑ ❑ 316 Type 316 S. FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). Color: ________________ .5). Specify: ______________ . PVC Blade Seals.7).5] Undersize standard): ❑ U00 Exact Size. AXLES: 1/2" (13) dia. BLADE SPACING: Approx. Type 304 S. Drainable style. Aluminum Bird Screen. 39 5.61 30 .95 11.23 3.89 0.54 6.21 0.84 9.10 Nailor Industries Inc.00 11.0 (248.30 3.19 1.5) 200 300 (61.49 0.33 15.39 4.66 0.26 14.11 2.97 0.19 0.27 1.70 (174.55 17.71 0.08 12.45 0.09 0.07 0. (3 ml/sq.85 0. .05 12.64 1.20 2.47 5.13 0.36 0.08 0.08 12.14 1.34 48 1.85 10.66 1.15 2.78 0. reserves the right to change any information concerning product or pricing without notice.8) 2000 3000 (609.4) .91 1.4) .52 6.54 6.65 19.13 2.85 0.68 72 1.18 0.14 2.g.36 15.22 54 1.74 1.77 60 1.88 0.17 1.03 (7.03 (0.18 0.91 36 0.52 1.04 0.43 5./sq.FORMED STEEL ADJUSTABLE LOUVER 4" (102) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1704AD FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 .82 9.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).21 2.08 1.66 1.02 0.57 6.36 4.93 0.73 9.30 0. ENGINEER: CONTRACTOR: DATE B SERIES 12 .39 5.18 0.98 0.44 0.35 4.07 1.60 (149.04 0.80 9.23 0.85 0.34 4.82 0.38 4.45 5.62 7.24 3.g.90 10.18 14.65 0.96 0.7) INTAKE .16 0.85 0.52 1.47 5.64 0.40 5.44 5.98 1.46 0.17 0.54 1.07 12.29 3.65 7.03 0.2) .17 13.20 3.46 24 .73 8.42 4.49 24 0.16 0.44 1. (sq.37 1.20 2. ft.61 0.68 7.20 0.08 1.92 0.26 3.27 18 0.6) 991 fpm (302 m/min.83 78 1.24 1.74 0.84 0.04 0.76 0.09 1.30 18 . 5 .60 0.3) .43 0.10 (24.49 5.05 1.4) 1000 (304.30 (74.17 2.83 0. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).58 0.63 0.97 1.69 8.19 0.01 (2. ft.78 0.93 0.53 0.22 2.77 0.61 7.92 0.02 0.75 9.18 0.74 0.61 7.29 0. Standard air density @ 0. (27 Pa) NOTE: To minimize water penetration when sizing intake louvers.35 1.32 3.82 0.26 1.94 0.47 0.23 2.6) .45 16.07 1.52 0.51 6.32 0.58 0.85 0.45 5.45 6.56 6.30 0.84 10.4) 500 (152.03 0.81 1.25 3.80 0.07 0.38 4.13 0.22 0.60 18.0) (91.82 10.06 0.65 1.91 42 1.83 0.61 0.26 0.22 0.43 16.13 42 1.24 0.85 9. (Pa) I N T A K E Free Area % Free Area sq.075 lbs/ft 3 .75) Static Pressure Drop in Inches w.11 1.50 (124.70 30 0.02 (5.62 1.10 1.56 0.32 15. Previous View Home Contents Dimensions Performance Specification 1704AD .52 0.30 4.9) EXHAUST .54 1.) 7958 cfm (3755 l/s) .13 1.12 0.01 oz.23 0.25 2. m.86 21.37 0.52 66 1.16 13.04 12.38 1.04 0.16 2.25 14.21 14.13 90 2.40 (99.55 6.20 (49.74 8.61 7.22 1.18 0.58 0.57 1.14 1.91 10.51 0.32 4.35 1.57 7.98 84 2.51 1.07 48 1.11 0.26 3.) Free Area Velocity at Point of Beginning Water Penetration at .57 0.81 0.05 (12.56 0.63 0.73 19.64 8.5) .10 1.64 0.69 8.25 0.24 0.36 0.24 2.33 4.0) .98 PRESSURE DROP for 48" x 48" (1219 x 1219) Louver Size 50% 8.57 0.18 2.05 0.48 17.50 0.97 1.02 0.65 0.78 0. m) (15 min.17 3.44 12 0.83 0. w.44 0.95 11.11 1.46 0.37 60 1.06 1.96 11.05 0.20 2.51 0.81 1. test duration) Air Volume at 991 fpm Free Area Velocity Pressure Drop @ 991 fpm 1.29 96 2.17 2.30 4.80 0.75 9.40 0.1 .64 7.11 in.56 AIRFLOW / WATER PENETRATION DATA 54 1.15 1.70 0.66 1. select a Free Area Velocity that is below the point of beginning water penetration.3 .26 4.83 0.84 0.10 1700 SUPERSEDES DRAWING NO.76 36 0.73 1.61 0.99 11.0) .47 5. Insect Screen. Type 304 S. ❑ U38 Undersize 3/8" (9. BIRD SCREEN FLANGED FRAME (FL) (OPTIONAL) SCHEDULE TYPE: PROJECT: Page 1 of 2 Dimensions are in inches (mm). ❑ ❑ ❑ ❑ ❑ ❑ ❑ 316 Type 316 S. Color: ________________ .10 Nailor Industries Inc. MAXIMUM SINGLE SECTION SIZE: 48" wide x 96" high (1219 x 2438) with jamb and/or blade seals.Model 1706AD adjustable. Type 304 S. FORMED STEEL ADJUSTABLE LOUVER 6" (152) DEEP • DRAINABLE BLADE MODEL: 1706AD NO M. drainable blade louver combines architecturally pleasing aesthetics with airflow control including tight shut-off. No Jamb Seals. ENGINEER: CONTRACTOR: DATE B SERIES 12 . JAMB SEALS: Compression type cambered metal. Construction.S. Specify: ______________ . WI DT H– 1/4 " (6 )S TD . FR1 1" (25) Filter Rack. FR2 2" (51) Filter Rack. Aluminum Bird Screen. BLADE SPACING: Approximately 5" (127) on centers. 6" (152) OPTIONS: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ FL BPV JSN BSA BSSS BSN ISA ISSS 304 Flanged Frame. Aluminum Insect Screen. LINKAGE: Plated steel. Previous View Home Contents Dimensions Performance Specification 1706AD .7). HEIGHT – 1/4" (6) STD.S. (1. Bird Screen. ❑ PC4 High Performance Powder Coat AAMA 2604 (Equivalent to 50% Kynar ® ). stainless steel sleeve type. OPTIONAL FINISHES: ❑ PC3 Powder Coat AAMA 2603. plated steel.5). SCREEN: 1/2" x 1/2" x 19 ga. ESI Extended Sill. BEARINGS: 1/2" (13) dia. No Bird Screen. 16 ga. 16 ga. WE Welded Construction. OPERATOR: Hand locking louver quadrant. ❑ U50 Undersize 1/2" (12. the design features a drainable blade with rain gutters that divert collected water down concealed side downspouts and out the sill.1 . Model 1706AD provides operable flexibility as well as excellent protection against the elements.0) galvanized bird screen in removable frame (adds approximately 3/8" [10] to louver depth). 60" wide x 96" high (1524 x 2438) without seals. STANDARD CONSTRUCTION: FRAME: BLADES: 6" (152) deep. MINIMUM SIZE: 12" wide x 12" high (305 x 305). PVC Blade Seals. FINISH: Mill. ❑ PC5 Fluoropolymer Powder Coat AAMA 2605 (Equivalent to 70% Kynar ® ). (13 x 13 x 1. Color: ________________ .10 1700 SUPERSEDES DRAWING NO.6) formed galvanized steel. Drainable style. Concealed in frame. The blades can be operated manually or with an actuator to provide tight shut-off when desired. Rugged galvanized steel construction provides excellent durability. 5 . AXLES: 1/2" (13) dia. (1. PAC Perimeter Anchor Clips. reserves the right to change any information concerning product or pricing without notice. Larger louvers will require field assembly of smaller sections. NOM. ACT Electric or Pneumatic Actuator.3 . ❑ Other: _______________ .S. Suitable for use in exhaust and low to medium velocity intake applications. Construction.S. ❑ PCC Prime Coat.6) formed galvanized steel at 37 1/2 degree angle. Color: ________________ . 1 1/2" (38) OPTIONAL W x H SIZING (1/4" [6. Type 304 S.5] Undersize standard): ❑ U00 Exact Size. 42 5.03 0.29 3.10 in. SCHEDULE TYPE: PROJECT: Page 2 of 2 Dimensions are in inches (mm).92 0.93 0.11 1.47 0.33 5.62 7.05 12.74 9.95 0.12 1.76 0.29 96 2.80 (0.31 4.81 10.80 9.97 0. w.38 0.58 7.69 0.93 10.23 1.04 0.1 .69 1.07 1.52 0.06 0.67 8.45 0.22 1.84 0.92 10.26 3.03 0.87 10.74 0. (25 Pa) NOTE: To minimize water penetration when sizing intake louvers.92 0.46 5.36 5.62 7.57 6.59 0.8) 2000 3000 (609.46 48 1.16 0.50 (124.59 1.57 0. 5 .65 0.10 1700 SUPERSEDES DRAWING NO.59 0.3 .36 1.12 1.68 0.68 19.27 0.15 13.46 0.75 0.18 2.78 1.24 2.57 1.99 0.60 7.46 24 .07 1.10 (24.60 (149.46 0. (sq.63 0.03 12.37 0.61 30 .74 1.02 (5.40 (99.075 lbs/ft 3 .71 8.07 12.46 0.47 6.98 0.5) 200 300 (61.13 90 2.23 0.17 0.05 0.93 1.20 3.34 4.17 13.52 6.) Free Area Velocity at Point of Beginning Water Penetration at .51 0.81 9.44 12 0.26 3.86 1.FORMED STEEL ADJUSTABLE LOUVER 6" (152) DEEP • DRAINABLE BLADE PERFORMANCE DATA MODEL: 1706AD FREE AREA in Square Feet and Square Meters Height in Inches and Meters Width in Inches and Meters 12 .0) .24 2.6) .66 0.11 2.67 7.22 1.53 7.80 0.76 36 .82 0.21 1.03 (7. m) (15 min.82 9.16 1.58 1.34 0.42 0.30 0.0) (91.89 1.32 3.86 0.05 (12.) 8598 cfm (4057 l/s) .16 PRESSURE DROP AIRFLOW / WATER PENETRATION DATA 1.66 8.83 0.41 4.52 2.49 5.42 5.66 1.37 60 1.31 1.9) EXHAUST .20 2.21 2. (Pa) I N T A K E Free Area % Free Area sq.15 2. test duration) Air Volume at 977 fpm Free Area Velocity Pressure Drop @ 977 fpm 977 fpm (298 m/min.96 0.20 0.02 0.40 5.22 2. ft.82) Static Pressure Drop in Inches w.14 1.19 2.48 5.71 8.01 (2.53 24 0.10 Nailor Industries Inc.39 0. ENGINEER: CONTRACTOR: DATE B SERIES 12 .4) .92 11.59 7.89 10.29 1.23 1.83 78 1.20 0.09 0.70 (174.22 3.19 0. select a Free Area Velocity that is below the point of beginning water penetration.71 8.45 16.98 84 2.27 14.30 (74.4) 1000 (304.00 0.57 0.01 0.18 3.91 1.09 1.2) .57 0. Previous View Home Contents Dimensions Performance Specification 1706AD .46 5.76 0. m.80 0.15 1.93 11.56 0.41 5.37 15.94 0.50 0.26 0.71 1.55 1. ft.60 7.30 0.22 2.18 14.88 0.0) .0 (248.49 0.14 0.23 42 1.53 0.10 12.4) .74 0.72 1.28 3.35 4.03 0.67 0.23 0.38 15.18 0.99 36 0.34 4.68 72 1.6) (914) Air Velocity in Feet (Meters) Per Minute Through Free Area Louver test size: 48" x 48" (1219 x 1219 mm).93 0.12 1.93 0.91 11.26 0.05 1.09 0.g.10 1.40 0.37 4.95 0.69 54 1.16 2.7) INTAKE .74 8.07 48 1.50 6.02 23.75 8.19 0.70 0.20 (49.16 0.16 0./sq.34 0.89 21.48 17.41 0.40 4.31 15.35 0.08 1.52 66 1.80 20.26 3.30 0.91 42 1.05 0.73 1.46 0.71 0.01 oz.38 0.30 18 .55 0.65 0.54 6. reserves the right to change any information concerning product or pricing without notice.58 18.32 3.69 0.19 13.76 20.72 0.14 2.63 0.37 1.16 2.40 1.g.4) 500 (152.61 0.62 18.27 3.45 17. .43 4.97 0.80 0.51 6.76 30 0.33 0.80 1.28 14.18 2.49 0.82 1.67 0. Standard air density @ 0.98 11.80 0.6) for 48" x 48" (1219 x 1219) Louver Size 55% 8.23 0.10 0.74 2.30 4.30 18 0.82 9.14 13.74 1.10 1.91 1. (3 ml/sq.00 11.01 0.45 1.26 2.3) .08 1.05 1.69 0.46 6.57 18.22 54 1.21 2.54 0.93 60 1.04 12.26 3.53 0.76 0.29 15.78 0.5) .67 8.88 0. #319 cast aluminum. with cast face mullions on 8" (203) centers. SCREEN: 7 x 7 aluminum mesh insect screen. A rear water stop minimizes water penetration. FINISH: Mill. BLADES: #319 cast aluminum. allowing for installation in accessible exterior areas. Rugged cast or extruded aluminum construction resists potential damage due to vandalism.125" (3) thickness. crawl spaces and other utility areas. secure means of ventilating foundations. Standard insect screen prevents unwanted pests from entering through the vent. minimum . and top and bottom drips prevent water from staining brick. All models are available with an optional damper for volume control and an extended sleeve suitable for duct connection if desired. STD. SIZES: NOMINAL HEIGHT FRAME: 4" (102) Width x Height 8" x 2 1/4" (203 x 57) 8 1/4" x 4 15/16" (210 x 125) INSECT SCREEN 8" x 7 7/8" (203 x 200) 12" x 2 3/4" (305 x 70) WATER STOP 12" x 3 1/2" (305 x 89) 12" x 5" (305 x 127) 12" x 7 3/4" (305 x 197) BOTTOM DRIP 16 1/2" x 2 3/8" (419 x 60) MODEL 16BVC 16" x 4" (406 x 102) 16" x 4 15/16" (406 x 125) 16" x 6" (406 x 152) 16" x 7 3/4" (406 x 197) Previous View Home Contents Dimensions Performance Specification 71 .125" (3) thickness. Deep louvered blades exhibit a minimum 39% free area and provide for minimal through-viewing. TOP DRIP MODEL 16BVC STANDARD CONSTRUCTION: 4" (102) deep. Optional finishes are available. ideal for new construction. minimum . All models incorporate a rear water stop and full width weepage openings for minimal water penetration during severe weather. MODEL 16BVC Model 16BVC features corrosion resistant cast aluminum construction that is suitable for load bearing applications.BRICK VENTS • CAST OR EXTRUDED ALUMINUM • HEAVY DUTY CONSTRUCTION • FOR NEW CONSTRUCTION OR RENOVATIONS MODELS: 16BVC CAST ALUMINUM 16BVE EXTRUDED ALUMINUM 16BVF EXTRUDED ALUMINUM WITH FLANGE Model 16BVF Model 16BVC Model 16BVE Nailor 16BV Series Brick Vents provide a permanent. 125" (3. Non-standard sizes are also available. STD. widths shown below do not include blade fasteners (add 1/4" (6)). heights shown below do not include top and bottom mortar ribs (add 1/4" (6)). SCREEN: 18 x 14 mesh aluminum insect screen. NOTE: For Model 16BVF. TOP DRIP TOP RIBS FRAME: 4" (102) deep. Integral top and bottom mortar ribs. . .BRICK VENTS MODEL 16BVE Model 16BVE features corrosion resistant extruded aluminum construction with top and bottom mortar ribs. with integral storm lip. FINISH: 204-R1 clear anodized finish.18) nominal wall thickness. Overlapping blades with storm lip exhibit a 35% free area and. SIZES: See below. . with integral 1" (25) flange.18) nominal wall thickness.18) nominal wall thickness.125" (3. fixed at 45 degrees. The 1" (25) flange provides an attractive finished appearance that conceals any rough edges in the opening. minimize water penetration.125" (3. INSECT SCREEN NOMINAL HEIGHT 1 1/4" (32) deep. Integral top and bottom drips prevent water from staining brick. combined with a rear frame water stop. Type 6063-T5 extruded aluminum. SIZES: See below.18) nominal wall thickness. BLADES: 1" (25) deep on 1" (25) centers. SCREEN: 18 x 14 mesh aluminum insect screen. STD. combined with a rear frame water stop. NOMINAL HEIGHT + 2" (51) FRAME: BLADE WITH STORM LIP 1" (25) WATER STOP OVERLAP WALL FLANGE MODEL 16BVF MODELS 16BVE & 16BVF STANDARD SIZES ( Width x Height ): 8 1/8" x 2 3/8" (206 x 60) 8 1/8" x 4 3/4" (206 x 121) 8 1/8" x 7 3/4" (206 x 197) 12" x 4 3/4" (305 x 121) 72 Previous View 12" x 7 3/4" (305 x 197) 12" x 11 3/4" (305 x 298) 15 5/8" x 7 3/4" (397 x 197) 15 5/8" x 15 3/4" (397 x 400) Home Contents 16 1/2" x 2 3/8" (419 x 60) 16 1/2" x 4 3/4" (419 x 121) 16 1/2" x 7 3/4" (419 x 197) 16 1/2" x 15 3/4" (419 x 400) Dimensions 24" x 4 3/4" (610 x 121) 24" x 7 3/4" (610 x 197) 32" x 7 3/4" (813 x 197) 48" x 7 3/4" (1219 x 197) Performance Specification . Type 6063-T5 extruded aluminum. .125" (3. NOMINAL HEIGHT MODEL 16BVE STANDARD CONSTRUCTION: NOTE: For Model 16BVE. Non-standard sizes are also available. Overlapping blades with storm lip exhibit a 35% free area and. Optional finishes are available. FINISH: 204-R1 clear anodized finish. Type 6063-T5 extruded aluminum. with integral storm lip. Optional finishes are available. NOMINAL HEIGHT + 1/4" (6) 4" (102) INSECT SCREEN BOTTOM DRIP BOTTOM RIBS WATER STOP BLADE WITH STORM LIP MODEL 16BVE MODEL 16BVF Model 16BVF features corrosion resistant extruded aluminum construction with a flanged frame that is ideal for use in renovations or existing openings. fixed at 45 degrees. 1 1/4" (32) MODEL 16BVF STANDARD CONSTRUCTION: BLADES: 1" (25) deep on 1" (25) centers. minimize water penetration. ideal for new construction. Type 6063-T5 extruded aluminum. The result is an exceptional finish that better resists scratching. "Complete Air Control and Distribution Solutions. chalk resistance.Louver Finishes & Color Guide Slate Blue LF01 Medium Bronze LF02 Sandstone LF03 Light Gray LF04 Charcoal LF05 Bone White LF06 Western Tan LF07 Architectural Bronze LF08 Regal Blue LF09 Forest Green LF10 Surrey Beige LF11 Royal Brown LF12 Barn Red LF13 Burgundy LF14 Clay LF15 Almond LF16 Coastal White LF17 Vista Green LF18 Black LF19 Gloss Black LF20 Campus Green LF21 Nailor offers 21 standard paint colors selected for architectural exterior use which meet or exceed AAMA specifications and performance requirements for color retention. erosion. c o m Specification ." Previous View Home Contents Dimensions Performance w w w. Custom color matching is also available upon request. Additional liquid coat facilities for special requirements complete our ability to provide unmatched beauty and durability for any application. Our state-of-the-art powder coat system provides an environment friendly finishing solution with more uniform coverage and coating thickness. corrosion and chemical resistance as well as dry film thickness and hardness. n a i l o r. Contact your local Nailor representative. gloss retention. fading and general wear. 7 mil. medium. when applied to a variety of exterior architectural applications. This technology represents the “ultimate” in environmentally friendly finishes.) Architectural Class I.7 mil. ® Envirocron Durable Powder. Interpon® D2000) "Better" − A high performance polyester powder coating. A good alternative to 50% Kynar 500® / Hylar 5000® liquid coatings. Powdura ® is a registered trademark of The Sherwin-Williams Company. Inc.7 mil. Interpon® D3000-Fluoromax) "Ultimate" − A next generation hyper durable powder coating.K." Previous View Home Contents Dimensions 11/13/09 w w w. A new alternative to traditional 70% Kynar 500® / Hylar 500® PVDF fluoropolymer liquid coatings. Envirocron® Ultra Durable Powder. which provides excellent resistance to outdoor weathering.) Architectural Class II. 5 years Prime Coat Prime coat provides a stable base for painting of louvers in the field. U. based on FEVE fluoropolymer resins and ceramic pigmentation that the industry has acknowledged as the foundation for superior performance coatings. Coraflon® Powder. Recommended for normal weather exposure. Interpon D1000) 1 year Clear Anodize 215-R1 AA-M10C22A41 (0. Zero – VOC emissions.) Architectural Class I. Clear. with Zero-VOC emissions. colorless and hard oxide aluminum coating that resists weathering and chemical attack. that can contaminate the final finish and cause premature flaking or peeling. Surface pretreatment includes degreasing and a chemical cleaning before an epoxy prime coat is applied. based on “super durable” resins that utilize infrared reflective pigments. 1 year Color Anodize AA-M10C22A44 (0. Inc. a second electrolytic process deposits colored metallic pigments which penetrate the aluminum oxide pores. n a i l o r. dark bronze and black. 10 years (Consult Nailor for availability of extended warranty) High Performance Powder Coat AAMA 2604 − High Performance Finish (AKA: Powdura® 4000. with superior color and gloss retention.4 − 0. N/A Paint finish warranties are not applicable to steel products. Finish coat should be field applied as soon as possible for best adhesion. Hylar 5000® is a registered trademark of Solvay Solexis. They provide a hard surface that is resistant to scratching and scuffing. min. producing a corrosion resistant. 5 years Durable Powder Coat "Good" − A durable powder coat based on thermosetting polyester resin technology. Following a standard anodizing procedure. Recommended for severely corrosive and abrasive atmospheric exposure. Inc. colorless and hard oxide aluminum coating that resists weathering and chemical attack. Dynadure™ 400. colorfast finish. "Complete Air Control and Distribution Solutions. AAMA 2603 − Provides a good economical combination of physical and chemical Pigmented Organic Coatings resistance properties. "Two-step" aluminum coating process. Interpon® is a registered trademark of Akzo Nobel Powder Coatings Ltd. Clear. A harder and more environmentally friendly coating than other liquid paint counterparts and with Zero-VOC emissions. Environmentally superior to liquid spray paints and ® (AKA: Powdura 3000. Houston  Las Vegas  Toronto  Calgary  Thetford. min. 5 years Clear Anodize 204-R1 AA-M10C22A31 (0. c o m Performance Specification . Coraflon® and Envirocron® are registered trademarks of PPG Industries Ohio. Available in light.Available Finishes FINISH TYPE DESCRIPTION STANDARD WARRANTY Fluoropolymer Powder Coat AAMA 2605-Superior Finish (AKA: Powdura® 5000. Kynar 500® is a registered trademark of Arkema. after a thorough cleaning for dust etc. ® ™ Dynadure 300. Norfolk IP24 3WB England Tel: (0) 1842 753624 Fax: (0) 1842 762032 www. Houston.co.A. etford WB. Thetford. Burrell Way. Tel: 281-590-1172 Fax: 281-590-3086 www.uk Underfloor Air Distribution Products. dquaters: UK) Ltd. including: • • • • • Canadian Headquarters: Nailor Industries Inc.com Grilles and Registers Ceiling Diffusers Linear Diffusers Plenum Slot Diffusers Fire Rated Assemblies Air Control Products. 000 T 1.S.nailor.nailor.S. 4714 Winfield Road.advancedair. Air Distribution Products. 98 Toryork Drive.7 Digital Catalog: The above four catalogs are also available together on CD Rom. Toronto. including: • Grilles and Registers • Floor "Swirl" Diffusers • Underfloor Fan Powered Terminal Units • Underfloor Fan Coil Terminal Units TIONS" ive. England 3624 62032 LOUVERCAT NOVEMBER 2009 Previous View USA Home Contents Dimensions • CANADA Performance • ENGLAND Specification . including: U.Additional products from Nailor are presented in the following comprehensive catalogs. Ontario M9L 1X6 Canada Tel: 416-744-3300 Fax: 416-744-3360 Single Duct Dual Duct Fan Powered Bypass Retrofit European Headquarters: Advanced Air (UK) Ltd. including: • • • • • “Complete Air Control and Distribution Solutions” www. and Corporate Headquarters: Nailor Industries of Texas Inc.com • • • • • Control Dampers Fire Dampers Ceiling Dampers Smoke Dampers Combination Fire/Smoke Dampers • Access Doors VAV Terminal Units. TX 77039 U.
Copyright © 2024 DOKUMEN.SITE Inc.