LG_MULTI_F_3828A20097W_1[1]

March 24, 2018 | Author: Claudiu Radu | Category: Air Conditioning, Mechanical Fan, Hvac, Pipe (Fluid Conveyance), Vacuum Tube


Comments



Description

Internal Use Only http://biz.lgservice.com Multi Type Air Conditioner SVC MANUAL(Exploded View) MODEL • Indoor Unit: Duct Type AMNH096BTG0 AMNH126BTG0 AMNH186BTG0 AMNH096BPA0 AMNH126BPA0 AMNH186BHA0 AMNH246BHA0 AMNC246BHA0 AMNH306BGA0 AMNC306BGA0 AMNH366BGA0 AMNC366BGA0 AMNH09GB1A0 AMNH12GB1A0 AMNH18GB2A0 AMNH24GB2A0 Room Type AMNH076LQL0 AMNH096LQL0 AMNH096LRL0 AMNH126LRL0 AMNH186LTL0 AMNH246LTL0 AMNH07GD4L0 AMNH09GD4L0 AMNH12GD4L0 AMNH18GD5L0 AMNH24GD5L0 4 Way CST AMNH096TEC0 AMNH126TEC0 AMNH186TEC0 AMNH246TFC0 AMNH306TFC0 AMNH366TDC0 AMNH306TFA0 AMNC306TFC0 AMNC366TDC0 AMNH09GTEF0 AMNH12GTEF0 AMNH18GTEF0 AMNH24GTHF0 1 Way CST AMNH096TCC0 AMNC096TCC0 AMNH126TCC0 AMNC126TCC0 AMNH09GTCC0 AMNH12GTCC0 Art Cool Deluxe Type AMNH076DZ*0 AMNH096DU*0 AMNH126DU*0 AMNH186D3*0 AMNH246D3*0 AMNH07GDZ*0 AMNH09GDU*0 AMNH12GDU*0 AMNH18GD3*0 AMNH24GD3*0 AMNH07GDE*0 AMNH09GDE*0 AMNH12GDE*0 Art Cool Type AMNH096AP*1 AMNH126AP*1 CVT AMNH096VEA0 AMNH126VEA0 AMNH186VBA0 AMNH246VBA0 • Outdoor Unit: A2UW146FA0 A2UW166FA0 A3UW186FA0 A4UW246FA0 A4UW306FA0 A2UW146FA1 A2UW166FA1 A3UW186FA1 A4UW24GFA0 A4UW306FA1 A2UW146FA2 A2UW186FA0 A3UW246FA0 A4UW30GFA0 A6UW406FA0 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. Multi type Air Conditioner Service Manual TABLE OF CONTENTS Model Number Nomenclature ....................................................................................................................3 Symbols Used in this Manual ...................................................................................................................5 Safety Precautions ......................................................................................................................................6 Dimensions ................................................................................................................................................12 Indoor Unit..............................................................................................................................................12 Outdoor Unit ...........................................................................................................................................21 Product Specifications ............................................................................................................................22 Installation .................................................................................................................................................34 Select the best location of indoor unit ....................................................................................................34 How to fix ...............................................................................................................................................37 Piping and Drainage of Indoor Unit ........................................................................................................45 Connection of indoor unit piping.............................................................................................................46 Remote Controller Installation ................................................................................................................69 Connecting Pipings and the cable to Outdoor unit .................................................................................71 Checking the Drainage and Pipe forming...............................................................................................74 Maximum Length of Pipe and Extra Charge of Refrigerant Charge.......................................................79 Test Running ..........................................................................................................................................85 System Layout and Piping Length..........................................................................................................88 Installation ..............................................................................................................................................89 Installation of The Main Unit...................................................................................................................90 Connection of Piping ..............................................................................................................................91 Connection of Wiring ..............................................................................................................................92 Operation ..................................................................................................................................................93 Function of control..................................................................................................................................93 Function of Indoor Unit ...........................................................................................................................98 Function of Outdoor Unit ......................................................................................................................104 Remote Control Operation ...................................................................................................................105 Control Devices and Function ...............................................................................................................114 Simple Central Control .........................................................................................................................114 Term of Each part and Function ...........................................................................................................114 Electrical wiring ....................................................................................................................................115 Deluxe Central Control .........................................................................................................................121 Disassembly of the parts (Indoor unit) .................................................................................................127 Indoor unit ............................................................................................................................................127 Schematic Diagram .................................................................................................................................142 Electronic Control Device .....................................................................................................................142 Wiring Diagram.....................................................................................................................................154 Components Locations.........................................................................................................................160 Troubleshooting Guide ...........................................................................................................................179 Refrigeration Cycle Diagram ................................................................................................................179 Self-diagnosis Function ........................................................................................................................186 Cycle Troubleshooting Guide................................................................................................................187 Electronic Parts Troubleshooting Guide ...............................................................................................188 General Information..............................................................................................................................193 (3-way) Valve ...........................................................................................................................................209 Exploded View .........................................................................................................................................213 Indoor Unit ...........................................................................................................................................213 Outdoor Unit ........................................................................................................................................242 Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes -2- LGE Internal Use Only Model Number Nomenclature Model Number Nomenclature Indoor Unit AMN H 07 6 L Q A 0 Serial Number Function A : Basic, L : Nano Plasma + Auto Clean(Wall Mounted) C: Plasma(Ceiling Cassette), G: Low Static Motor ART COOL(DELUXE) Type Front Panel Color B : Blue, D : Wood, M : Meta, R : Mirror, W : White Chassis Name Indoor Unit Type L : Wall Mounted , A : ART COOL D : ART COOL DELUXE, T : Ceiling Cassette B : Ceiling Concealed Duct V : Ceiling & Floor(Convertible) D : D Look (Wall Mounted) Electrical Rating 6 : 1Ø, 220-240V, 50Hz G : 220~240V, 50/60Hz Nominal Cooling Capacity in Btu/h Ex) 7,000 Btu/h '07', 18,000 Btu/h '18' Model Type H : Heat Pump TPS Inverter Multi System Indoor Unit Outdoor Unit A2U W 18 6 F A 0 Serial Number Function A : Basic Multi Type F : Free Joint Multi Type Electrical Ratings 6 : 1Ø, 220-240V, 50Hz 8 : 3Ø, 380-415V, 50Hz Nominal Cooling Capacity in Btu/h Ex) 18,000 Btu/h '18', 48,000 Btu/h, 50Hz '48' Model Type W : DC Inverter Heat Pump R410A TPS Inverter Multi System Outdoor Unit. And No. of Connectable Indoor Units Ex) A2U : Connectable max. 2 Indoor Units A6U : Connectable max. 6 Indoor Units Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes -3- LGE Internal Use Only Model Number Nomenclature Panel (Cassette, Built in Duct) Category CHASSIS PANEL NAME PT-CFA TF PT-CFC PT-HFA PT-HFC PT-CCA TC,TC1 CST PANEL TE(family look) PT-CCC PT-HCA PT-HCC PT-HEA PT-HEC PT-CEA PT-CEC TE1(family look) PT-HEA1 PT-HEC1 PT-HAD TD(family look) PT-HDC PT-CDA PT-CDC TH(family look) BUILT IN DUCT BP BQ E 5 A 6 Basic Number 1, 2 3 4 5 6 Contents Panel for Cassette Cooling/Heatpump Chassis Name Function Plasma Filter Elevation Grille Elevation Grille + Plasma Filter TE/TB/TD Before 2003 : Basic TE/TD Before 2003 : Plasma Filter PT-HDA1 PT-HDC1 PB-HPA PB-HQA 6. Function Function A B C D E F 0 1 PANEL P/NO. 3721A10072B 3721A10072G 3821A10072A 3721A10072E 3721A10023Z 3721A10023W 3721A10023Y 3721A10023V 3721A10105A 3721A10105B 3721A10105C 3721A10105D 3721A10105M 3721A10105N 3721A10106A 3721A10106B 3721A10106C 3721A10106D 3721A10106X 3721A10106Z 3721A20168A 3721A20168B 8435002994057 8435002994064 8435002994071 8435002994088 SERIAL NO. 8435002992862 8435002992879 8435002992886 8435002992893 8435002994095 8435002994101 8435002994118 8435002994125 8435002992978 8435002992985 8435002992954 8435002992961 Remark COOLING COOLING + PLASMA HEATING HEATING + PLASMA COOLING COOLING + PLASMA HEATING HEATING + PLASMA HEATING HEATING + PLASMA COOLING COOLING + PLASMA HEATING HEATING + PLASMA HEATING HEATING + PLASMA COOLING COOLING + PLASMA HEATING HEATING + PLASMA 9K/12K 18K/24K P 1 T 2 3 H 4 5. Chassis Name Chassis Abbrevation TC C TB B TD D TE E TF F TH H TJ J BP P BQ Q Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes -4- LGE Internal Use Only Model Number Nomenclature Indoor Units Category Type Chasiss 2.1 (7000) AMNH 076LQL0 AMNH 07GD4L0 2.6 (9000) AMNH 096LQL0 AMNH 096LRL0 AMNH 09GD4L0 AMNN 096AP*1 AMNH 096DU*0 09GDU*0 AMNH 07GDE*0 1Way TC,TC1 TE 4Way TE1 TF TH TD High Static BH BG BT Low Static B1 B2 Built in Ceiling & Floor Convertible BP VE VB AMNH 09GDE*0 AMNH/C 096TCC0 AMNH09 GTCC0 AMNH 096TEC0 AMNH 09GTEF0 AMNH 096BTG0 AMNH 09GB1A0 AMNH 096BPA0 AMNH 096VEA0 Model Name Capacity, kW(Btu/h) 3.5 5.3 (12000) (18000) AMNH 126LRL0 AMNH 12GD4L0 AMNN 126AP*1 AMNH 126DU*0 12GDU*0 AMNH 12GDE*0 AMNH/C 126TCC0 AMNH12 GTCC0 AMNH 126TEC0 AMNH 12GTEF0 AMNH 126BTG0 AMNH 12GB1A0 AMNH 126BPA0 AMNH 126VEA0 AMNH 18GD5L0 AMNH 186D3*0 18GD3*0 AMNH 186TEC0 AMNH 18GTEF0 AMNH 186BHA0 AMNH 186BTG0 AMNH 18GB2A0 AMNH 186VBA0 AMNH 24GD5L0 AMNH 246D3*0 24GD3*0 AMNH 246TFC0 AMNH 24GTHF0 AMNH 246BHA0 AMNH 24GB2A0 AMNH 246VBA0 AMNH 186LTL0 7.0 (24000) AMNH 246LTC0 8.8 (30000) 10.6 (36000) - SQ SR Wall Mounted General ST S4 S5 General SP1 SZ ART Cool Mirror SU S3 SE AMNH 076DZ*0 07GDZ*0 AMNH/C 306TF*0 AMNH/C 306BGA0 - AMNH/C 366TDC0 AMNH 366BGA0 - Ceiling Cassette Ceiling Concealed Duct Outdoor Units TPS Inverter Multi Series Heat Pump Rated Capacity Model Name A2UW146FA0/1/2 A2UW166FA0/1 Cooling kW(Btu/h) 4.1(14000) 4.7(16000) Heating kW(Btu/h) 4.7(16000) 5.3(18000) Number of Indoor Units to be Connected Max.2 Units Max.2 Units Indoor Units kW 2.1~6.2 2.1~7.0 Connectable Capacity Btu/h 7000~21000 7000~24000 Power Supply Multi Piping Type A2UW186FA0 A3UW186FA0/1 A3UW246FA0 A4UW246FA0 A4UW306FA0 5.3(18000) 5.3(18000) 7.0(24000) 7.0(24000) 8.8(30000) 6.3(21600) 6.3(21600) 8.2(28000) 8.2(28000) 10.1(34500) Max.2 Units Max.3 Units Max.3 Units Max.4 Units Max.4 Units 2.1~7.0 2.1~8.8 2.1~9.7 2.1~11.4 2.1~11.4 7000~24000 7000~30000 7000~33000 7000~39000 7000~39000 1Ø, 220-240V, 50Hz A4UW306FA1 8.8(30000) 10.1(34500) Max.4 Units 2.1~11.4 7000~39000 Distributor Type A6UW406FA0 11.7(40000) 13.5(46000) Max.6 Units 4.7~15.2 16000~52000 A7UW486FA0 14.0(48000) 16.2(55200) Max.7 Units 5.6~18.3 19200~62400 A8UW566FA0 16.4(56000) 18.9(64400) Max.8 Units 6.6~21.3 22400~72800 Notes : A2UW146FA0/1/2, A2UW166FA0/1, A2UW186FA0 and A3UW186FA0/1 are not TPS inverter system but one inverter compressor system. Symbols Used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner. NOTICE This symbol indicates special notes. Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes -5- LGE Internal Use Only This symbol indicates the possibility of injury or damage to properties only. WARNING CAUTION This symbol indicates the possibility of death or serious injury. Always install a dedicated circuit and breaker. Use this appliance on a dedicated circuit. • Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker or fuse. Inc. Always ground the product. • There is risk of fire or electric shock. • There is risk of fire or electric shock. • There is risk of fire or electric shock. Copyright ©2007 LG Electronics. I Meanings of symbols used in this manual are as shown below. The seriousness is classified by the following indications. For electrical work. • Do not disassemble or repair the product. or an Authorized Service Center. I Incorrect operation due to ignoring instruction will cause harm or damage. Be sure not to do. a qualified electrician. the following instructions must be followed. WARNING I Installation Do not use a defective or underrated circuit breaker. • There is risk of fire or electric shock. seller. All right reserved.Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage. There is risk of fire or electric shock. Install the panel and the cover of control box securely. contact the dealer. Only for training and service purposes -6- LGE Internal Use Only . Be sure to follow the instruction. Do not place anything on the power cable. Be especially careful of the case edges and the fins on the condenser and evaporator. or damage to the product. product failure. and personal injury. always contact the dealer or an Authorized Service Center. the air conditioner could fall with it. All right reserved. For installation. Inc. Do not install the product on a defective installation stand. • There is risk of fire or electric shock. • There is risk of fire or electric shock. Be sure the installation area does not deteriorate with age. • If the base collapses. or injury. Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. • There is risk of fire. Be cautious when unpacking and installing the product. or injury. Only for training and service purposes -7- LGE Internal Use Only .Safety Precautions Do not modify or extend the power cable. explosion. accident. explosion. • Sharp edges could cause injury. causing property damage. • It may cause injury. • Moisture may condense and wet or • There is risk of fire or electric damage furniture. or reinstall the unit by yourself (customer). Take care to ensure that power cable could not be pulled out or damaged during operation. Do not install. electric shock. shock. Copyright ©2007 LG Electronics. electric shock. remove. • There is risk of fire. • Do not use the telephone or turn switches on or off. or small or smoke comes from product. failure of product. or electric shock. Inc. • It may cause There is risk of fire. or electric shock. Copyright ©2007 LG Electronics. remove the product from the window before the hurricane arrives. If possible. • There is risk of property damage. • Oxygen deficiency could occur. Do not touch(operate) the product with wet hands. There is risk of explosion or fire If strange sounds. Only for training and service purposes -8- LGE Internal Use Only . Do not allow water to run into electric parts. Turn the breaker off or disconnect the power supply cable.Safety Precautions Do not plug or unplug the power supply plug during operation. • There is risk of fire or electric shock. Do not place a heater or other appliances near the power cable. failure of the product. Gasolin When flammable gas leaks. turn off the gas and open a window for ventilation before turn the product on. • There is risk of fire and electric shock. • There is risk of electric shock or fire. Do not use the product in a tightly closed space for a long time. All right reserved. Do not store or use flammable gas or combustibles near the product. • There is risk of fire or electrical shock. Stop operation and close the window in storm or hurricane. • There is risk of fire or failure of product. • This could result in personal injury and product damed operation. Take care to ensure that nobody could step on or fall onto the outdoor unit. All right reserved. Only for training and service purposes -9- LGE Internal Use Only . Inc. • There is risk of product damage or failure. etc. • A bad connection may cause water • To avoid vibration or water leakleakage. • There is risk of fire. if the unit is so equipped. When the product is soaked (flooded or submerged). age. • There is risk of fire or electric shock. Turn the main power off when cleaning or maintaining the product. or product damage. disconnect the power supply plug or turn off the breaker. 90° Copyright ©2007 LG Electronics. • There is risk of electric shock. Be cautious that water could not enter the product. contact an Authorized Service Center. electric shock.Safety Precautions Do not open the inlet grill of the product during operation. or unintend. Ventilate the product from time to time when operating it together with a stove. CAUTION I Installation Always check for gas (refrigerant) leakage after installation or repair of product. • Low refrigerant levels may cause failure of product. age.) • There is risk of physical injury. When the product is not be used for a long time. Keep level even when installing the product. (Do not touch the electrostatic filter. or product failure. electric shock. Install the drain hose to ensure that water is drained away properly. • There is risk of fire or electric shock. electric shock. particularly on the condenser and evaporator fins. works of art. Corrosion.Safety Precautions Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. x Wa Thinner Copyright ©2007 LG Electronics. • It may cause a problem for your neighbors. They are very sharp! • There is risk of personal injury.10 - LGE Internal Use Only . I Operational Do not expose the skin directly to cool air for long periods of time. • It may cause product failure. Use two or more people to lift and transport the product. etc. Use a soft cloth to clean. could cause product malfunction or inefficient operation. Do not install the product where it will be exposed to sea wind (salt spray) directly. Do not use the product for special purposes. Do not block the inlet or outlet of air flow. or damage to the plastic parts of the product. not a precision refrigeration system. Only for training and service purposes . • There is risk of fire. • There is risk of damage or loss of property. such as preserving foods.) • This could harm to your health. solvents. Do not use harsh detergents. • Avoid personal injury. All right reserved. • It may cause corrosion on the product. etc. (Don't sit in the draft. Do not touch the metal parts of the product when removing the air filter. Inc. It is a consumer air conditioner. Copyright ©2007 LG Electronics. • There are sharp and moving parts that could cause personal injury. Inc. • A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. Always insert the filter securely.11 - LGE Internal Use Only . All right reserved. • They may burn or explode. (outdoor units) • There is risk of personal injury and failure of product. Do not dispose of batteries in a fire. • The chemicals in batteries could cause burns or other health hazards. Do not use the remote if the batteries have leaked. Do not drink the water drained from the product. Use a firm stool or ladder when cleaning or maintaining the product. Do not insert hands or other objects through the air inlet or outlet while the product is operated. wash it well with clean water. Replace the all batteries in the remote control with new ones of the same type. Do not recharge or disassemble the batteries. Do not mix old and new batteries or different types of batteries.Safety Precautions Do not step on or put anyting on the product. • There is risk of fire or explosion • It is not sanitary and could cause serious health issues. • Be careful and avoid personal injury. If the liquid from the batteries gets onto your skin or clothes. Only for training and service purposes . Clean the filter every two weeks or more often if necessary. 12k 570 568 137 Copyright ©2007 LG Electronics. Inc. 24k 1080 314 172 S4 7k.Dimensions Dimensions Indoor Unit 1. 12k 840 270 153 S5 18k. All right reserved. 9k. Art Cool Type Indoor Unit W D H H W D Pipe Hole Hanger Hole Fix Hole Installation plate Model Dimension W H D mm mm mm SQ 7k.12 - LGE Internal Use Only . Split Type Indoor 2. 9k 824 260 155 SR 9k. 24k 1090 300 178 SP 9k. Only for training and service purposes . 12k 900 285 156 ST 18k. 24K 1170 315 173 SE 7K.Dimensions 3. Inc. All right reserved. 9K. 12K 1030 290 153 S3 18K. Art Cool Deluxe Type SZ.SU. Only for training and service purposes . 12K 895 282 165 Copyright ©2007 LG Electronics.13 - LGE Internal Use Only .S3 SE H H D W W D Installation plate Installation plate MODEL DIM W H D Unit mm mm mm SZ 7K 900 272 135 SU 9K. Inc.14 - LGE Internal Use Only . Duct Type W D H BH/BG W D W D H H BP BT/BT1/B1/B2 MODEL DIM W(mm) BT 9K/12K 708 BT1 18K 1060 BH 18K/24K 880 BG 30K/36K 1180 BP 9K/12K 580 B1 9K/12K 820 B2 18K/24K 1100 H(mm) 230 230 260 298 300 190 190 D(mm) 537 357 450 450 750 575 575 Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes .Dimensions 4. Inc.Dimensions 5. All right reserved. Only for training and service purposes .15 - LGE Internal Use Only . CVT Type VB(18K/24K) W H R D 63mm 38mm 26 5m 39 m 2m m 250mm 36 mm 46 8m m 175mm 10 76 mm (Installation Plate) 36 mm (Rear Side) VE(8K/12K) D H W Installation plate MODEL DIM W H D Unit mm mm mm VE 9K/12K 900 285 156 VB 18K/24K 1200 615 205 Copyright ©2007 LG Electronics. 4 42. Only for training and service purposes .6 Ø55 130 180 Ø80 430 155 91. All right reserved.Dimensions 6.16 - LGE Internal Use Only .6 893.52 flare Copyright ©2007 LG Electronics.TC.3 141.4 (Hanging bolt) 860 430 (Ceiling opening) 390 4 16.8 180 91.6 180 1050 694. Inc.4 (Hanging bolt) 30.4 860 846 328.7 390 328.8 30.TC1 (9K/12K) 1.5 5 480 6 (unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition ø6.4 164 37 97.7 7 931.35 flare ø9.6 893. CST Type .000 (Ceiling opening) 931.8 1 3 2 50 194.7 116. 17 - LGE Internal Use Only 52 .5 450 (Hanging bolt) 75 75 269 570 Unit size 670 670 570 Unit size Unit:mm 670 570 450 5 570 670 6 CLOSE OPEN OPEN CLOSE 521 40 4 600 (Ceiling opening) 1 2 3 30 110 269 90 30 120.4 110 90 190. 12k: Ø9.5 160 (unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition ø6.52. Only for training and service purposes .5 521(Hanging bolt) 39.Dimensions 7.7 flare Copyright ©2007 LG Electronics.35 flare 9k: Ø9. Inc. 18k: Ø12.TE(1) (9K/12K/18K) 600 (Ceiling opening) 39. All right reserved. CST Type .52. Only for training and service purposes .TF (24K/30K) 790 (Ceiling opening) 109 572(Hanging bolt) 109 66 292 850 850 744 Unit size 744 Unit size Unit:mm 850 744 658 5 850 572 744 6 70 4 1 2 117 110 90 110 90 150 3 292 66 790 (Ceiling opening) 212 192 30 (unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition ø6. CST Type . ø15.7 flare-24K.35 flare ø12. Inc.18 - LGE Internal Use Only 54 658 (Hanging bolt) . All right reserved.88 flare-30K Copyright ©2007 LG Electronics.Dimensions 8. Only for training and service purposes .88 flare-30K Copyright ©2007 LG Electronics.7 flare-24K.Dimensions 9.35 flare ø12. CST Type .TH (24K) 862 (Ceiling opening) 87 688(Hanging bolt) 87 28 255 950 950 840 840 Unit:mm 950 840 608 5 950 688 840 6 70 4 1 2 117 110 90 110 90 150 3 225 28 862 (Ceiling opening) 212 192 30 (unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition ø6. All right reserved. Inc.19 - LGE Internal Use Only 54 806 (Hanging bolt) . ø15. 5 90 .88 flare Copyright ©2007 LG Electronics. All right reserved.TD(36K) 875 (Ceiling opening) 45 785 (Hanging bolt) 45 101.5 110 288 950 950 840 Unit size 840 Unit size 950 Unit:mm 840 678 950 5 6 55 840 4 785 40 1 2 30 290 110 90 875 (Ceiling opening) 52 180 3 Fresh Air Inlet 140 (unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition ø6. Inc.5 672 (Hanging bolt) 101. CST Type .35 flare ø15. Only for training and service purposes .20 - LGE Internal Use Only 210.Dimensions 10. Inc. 18K 870 655 320 370 25 775 25 546 160 160 UE1 24K 870 800 320 370 25 775 25 546 160 160 UE2 30K 870 1060 320 360 20 1040 20 550 160 165 UH 40K 900 1165 370 460 45 1135 30 550 175 175 Copyright ©2007 LG Electronics.Dimensions Outdoor Unit D W W L2 L1 D H 30K/40K H L3 L4 L6 L5 L7 18K/24K MODEL DIM W H D L1 L2 L3 L4 L5 L6 L7 mm mm mm mm mm mm mm mm mm mm UL 14K.21 - LGE Internal Use Only . Only for training and service purposes . All right reserved. 16K 770 540 245 287 21 530 10 518 126 126 UE 14K. 0) 0.4*10.0) 0. of Poles Input Running Current Capacitor Fan Type No. N:Walnut.74(95) 1260 / 1140 / 1000 1260 / 1140 / 1000 46 / 43 / 39 Thermistor 0.35) 3/8 (9.4*6.9*14.7*5.21 2. Inc.13C 2R.7) 1/2 (12.43(87) 1200/1100/1000 1200/1100/1000 35 / 33 / 31 Thermistor 0.81 (1170*315*173) 46. C:Cherry Note : 1.52) 20 38.197(5.4 35.0 42. M:Metal.2*6.4*11.9 / 400 Cross Flow Fan Cross Flow Fan 1/3.0 / 370 Cross Flow Fan 1/3. W:White.5(194) 8.2 (1255*388*258) 49.9*12.9*10.35) 1/2 (12.4*6.197(5.18 0.6(976*233*372) 338/714 (340/720) Morning Beige AMNH186LTL0 4536(5275) 18000 4990(5803) 19800 13(459) 18~30 / 16~30 22 AMR-023E2 4 54 0.43(87) 1/3.22 - LGE Internal Use Only .2 1.12C 2R.7) 20 20 20 20 44.10C 1.197(5.4*10.35) 1/4 (6.11 0.7) 1/4 (6. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Front Panel Color "#" Position kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) °C W AMNH076DZ*0 1764(2051) 7000 1940(2257) 8000 5.13C 2.74(95) 1/3.9/400 0.35) 3/8 (9.2*6.8(1090*314*172) 12(26.0) 20 2R.35) 3/8(9.0) 19 19 20 20 2R.9*14.0(1030*290*153) 46.4 IC-8420LG48A 4 37 0.8(1090*314*172) 12(26.0 / 370 Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No. B:Blue.1*24.3(985*220*363) 340/720 AMNH096DU*0 ART COOL DELUXE AMNH126DU*0 AMNH186D3*0 AMNH246D3*0 W A µF/Vac EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft 2267(2638) 2772(3224) 4536(5275) 5796(6740) 9000 12000 18000 23000 2495(2901) 3049(3546) 4990(5803) 6426(7472) 10000 13200 19800 25500 8.8 25.9 / 400 Cross Flow Fan 1/3.4 8.7*14. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press.2 (1255*388*258) 324/684 324/684 234/495 234/495 R:Mirror.16 0.4*6.35) 1/4 (6.7) 20 45.9) 13(28.2*13.0 1.4) 1/4 (6.74(95) 1320/1220/1120 1400/1300/1200 1320/1220/1120 1400/1300/1200 37 / 33 / 31 39 / 36 / 34 40/38/36 44/42/40 Thermistor Thermistor Thermistor Thermistor 0.0) 19 2R.0) 20 2R.12C 2R.5(20.52) 20 38.5) 1/4 (6.2 32.4*15.6 25.9) 1/4 (6.3(900*272*135) 40.8 35.21 2.4*15.197(5.81 (1170*315*173) 9.276(7.4*9.43(87) 1/3.0) 0.8*8.6(976*233*372) 338/714 (340/720) Morning Beige AMNH126LRL0 3024(3515) 12000 3326(3867) 13200 9.5 42.9*10.4*9.43(87) 1080 / 970 / 880 1170 / 1100 / 1020 1080 / 970 / 880 1170 / 1100 / 1020 35 / 32 / 29 37 / 33 / 31 Thermistor Thermistor 0.0(318) 18~30 / 16~30 14.197(5.1(824*260*155) 7(15.43(87) 1330/1230/1130 1330/1230/1130 35 / 32 / 29 Thermistor 0.52) 20 20 35.7) 13(28. Only for training and service purposes .9/400 Cross Flow Fan 1/3. Copyright ©2007 LG Electronics.4*9.9 / 400 0.4*6.6*11.5(194) 18~30 / 16~30 4.0) 0.5) 1/4 (6. Due to our policy of innovation some specifications may be changed without notification.0*15.0*15.5 35. of Poles Input Running Current Capacitor Fan Type No.9) 9.4*10.2*6.52) 20 38.1(900*285*156) 8(17.3(1165*255*388) 264/536 (270/540) Morning Beige W A µF/Vac EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft 1764(2051) 2267(2638) 7000 9000 2016(2343) 2520(2929) 8000 10000 5.9/400 2.2*6.6) 1/4 (6.13C 2.4*9.5(300) 9.0 / 370 Cross Flow Fan 1/3.8(1090*314*172) 8.74(95) 1140 / 1040 / 940 1140 / 1040 / 940 42 / 39 / 36 Thermistor 0.2*13.35) 3/8 (9.0 42.35) 1/4 (6.2*14.3*10.5(300) 18~30 / 16~30 18~30 / 16~30 8.0 / 370 2.43(87) 1290 / 1200 / 1120 1290 / 1200 / 1120 39 / 36 / 34 Thermistor 0.0) 20 2R.197(5.8 7.18 0. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Front Panel Color "#" Position kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) °C W AMNH076LQL0 AMNH096LQL0 Wall Mounted AMNH096LRL0 2267(2638) 9000 2520(2929) 10000 8.# See the page "Combination Table" 2.4*6.0*8.4) 7(15.43(87) 1/3.16 0.0) 20 2R.12C 1.2*14.10C 2R.4 IC-8420LG48A 4 37 0.52) 1/2 (12.8(1117*225*377) 49.12C 1. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press. All right reserved.5 2 2.35) 1/4 (6.7 OBM-1547P2 4 27 0.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.12C 1.9*12.4*6.0) 19 19 2R.0*8.35) 1/2 (12.52) 3/8 (9.4 IC-8415LG62A IC-8415LG62A 4 4 25 25 0.197(5.4(900*233*340) 35.11 0.276(7.0(318) 13(459) 14(494) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 7.52) 3/8(9.9 / 400 Cross Flow Fan 1/3.9*12.4*11.5(300) 18~30 / 16~30 14.1(900*285*156) 8(17.1(824*260*155) 32.276(7.6) 1/4 (6.3*10.8(1117*225*377) 44.35) 3/8(9.15 0.13C 1.4(900*233*340) 354/774 (360/780) 354/774 (360/780) Morning Beige Morning Beige Indoor Unit Type Model Rated Cooling Capacity # Rated Heating Capacity # Air Circulation H/M/L Setting temperature range Fan motor Output Model No.1(17.6 OBM-1547P2 OBM-1547P2 OBM-2510P2 OBM-2510P2 4 4 4 4 40 40 58 58 0.21 0.276(7.3(1165*255*388) 264/536 (270/540) Morning Beige AMNH246LTL0 5544(6446) 22000 6099(7091) 24200 14(494) 18~30 / 16~30 29 AMR-023E5 6 59 0.Product Specifications Product Specifications Indoor Unit Indoor Unit Type Model Rated Cooling Capacity # Rated Heating Capacity # Air Circulation H/M/L Setting temperature range Fan motor Output Model No.5(20.12 0.7) 20 45.1*24. 7*13.0 33.4) 7(15.23 - LGE Internal Use Only .75 cmm cfm µF/Vac mm mm(inch) kg(lbs) dB(A)+3 mm(inch) mm(inch) l/h Coil Dimensions (WxHxD) Weight Air filter Sound level (H/M/L) Piping Liquid connections Gas Dehumidification rate Safety devices Temperature sensor Referigerant Referigerant control Connectable outdoor unit Power and transmission interunit cable No.0*11.197(5.5) 9.0*11. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Connection Liquid Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity With(Without) S/Parts Front Panel Color "#" Position kcal/h(W) Btu/h kcal/h(W) Btu/h CMM(CFM) °C W AMNH07GD4L0 AMNH09GD4L0 Wall Mounted AMNH12GD4L0 AMNH18GD5L0 AMNH24GD5L0 EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft 1764(2051) 2267(2638) 7000 9.0(318) 13(459) 14(494) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 20 20 20 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.200 19.15C 1.1*6.7(1165*387*246) 437/906 (432/896) 270/558 (267/552) 270/558 (267/552) Morning Beige Morning Beige Morning Beige Copyright ©2007 LG Electronics.52) 20 20 35. Thermal Protector for Fan Motor Thermistor R410A LEV(in Outdoor unit or BD) Multi F /F DX series 4*0.0(840*270*153) 7(15. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level (Sound Press.000 23.35 (1/4) 9.200 0.000 0.52 (3/8) 1.1*8.4) 13(28.8*7.2 2.52 12.15C 2R.000 3.52 (3/8) 1.3 3.1*6.1*8.9*15.5 Thermistor R410A LEV(in Outdoor unit or BD) Multi F /F DX series 4*0.7) 13(28.000 2.0*10.34 8.35) 3/8 (9.35) 1/4 (6.15 BLDC Cross Flow Fan 7.35 (1/4) 9.9) Long Life Filter 31/26/22 6.15C 0.52) 1/2 (12.93 10.0*10.197(5.05 7.0*10. All right reserved.7*13.4) 1/4 (6.8(906*332*223) 45.9) Long Life Filter 30/25/21 6.x mm2 Indoor Unit Type Model Nominal Cooling Capacity # Nominal Heating Capacity # Air Circulation H/M/L Setting temperature range(cool/heat) Fan motor Output Model Fan Type No.6*6.000 2016(2343) 2520(2929) 8000 10.0(840*270*153) 42.52) 3/8 (9.15C 2R.197(5.9) Long Life Filter 35/28/24 6.9*15.7*13.000 3326(3867) 4990(5803) 6426(7472) 13.2*9.5) 8.500 9.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.1 33.8(906*332*223) 35.8 X 1 8/7/5 282/247/177 Direct Drive 2R x 12C x 19 915x282x165 (36.75 AMNH12GDE*0[MC12AH*NE0] 1/ 220~240/ 50 3.000 18.800 25.74(95) 1000/870/750 1140/1000/800 1000/870/750 1140/1000/800 29 / 25 / 20 33 / 29 / 22 Thermistor Thermistor 0.75 ART COOL Mirror AMNH09GDE*0[MC09AH*NE0] 1/ 220~240/ 50 2.87 13.1*6.74(95) 1/3.0) 20 20 20 2R.0) 0.000 0.94(100) 1/3.2*9.15C 2R.2(290) 18~30 / 16~30 18~30 / 16~30 20 20 SIC-37CV-FI30-3 SIC-37CV-FI30-3 Cross Flow Fan Cross Flow Fan 1/3.0 Thermistor R410A LEV(in Outdoor unit or BD) Multi F /F DX series 4*0.000 5.0(840*270*153) 33.5) 9.0) 20 20 2R.8*7. Only for training and service purposes .9*11.0) 0.000 2.9*11.1(17.35) 1/4 (6. Inc.52 (3/8) 1.5(20.15 BLDC Cross Flow Fan 7.8(906*332*223) 437/906 (432/896) 437/906 (432/896) Morning Beige Morning Beige 3024(3515) 4536(5275) 5796(6740) 12.35) 1/4 (6.0) 0.8 X 1 10/8/6 353/283/212 Direct Drive 2R x 12C x 19 915x282x165 (36.35 (1/4) 9.7) 20 20 20 35.7(1165*387*246) 45.9 1.7) 1/2 (12.1*8.7) 1/4 (6.0*11.74(95) 1/3.5(194) 8.10 BLDC Cross Flow Fan 4.35) 3/8 (9.2 Fuse.5(20.0(1090*300*180) 7(15.6*6.6*6.Product Specifications Indoor Unit Type Model Power supply Cooling capacity Heating capacity Current Fan Nominal running current Motor type Fan type Motor output x Number of unit Air flow rate (H/M/L) Capacitor Drive Row x column x FPI Body Body Ø/V/Hz kW Btu/h kW Btu/h A AMNH07GDE*0[MC07AH*NE0] 1/ 220~240/ 50 2.7 X 1 7/6/4 247/212/141 Direct Drive 2R x 12C x 19 915x282x165 (36.94(100) 1250/1080/970 1200/1100/1000 1360/1260/1100 1250/1080/970 1200/1100/1000 1360/1260/1100 36 / 32 / 29 37 / 34 / 31 41 / 39 / 34 Thermistor Thermistor Thermistor 0.64 9.0(1090*300*180) 42.276(7.276(7. 0*14.4*22.74(95) 1150/1032/940 1280/1208/1147 1345/1273/1213 1330/1254/1123 1400/1332/1188 1150/1032/940 1280/1208/1147 1345/1273/1213 1330/1254/1123 1400/1332/1188 31/29/27 33/31/29 35/31/29 39/37/35 43/41/38 Thermistor Thermistor Thermistor Thermistor Thermistor 0. Due to our policy of innovation some specifications may be changed without notification.0(318) 13(459) 14(494) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 20 20 20 20 20 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 SIC-37CV-FI30-3 Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.C:Cherry Note : 1.20C 1.197(5.7) 20 20 20 20 20 38. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level (Sound Press.0 (1030*290*153) 46.5 35.4*5.276(7.4) 1/4 (6.8*14.4*10.0*14.000 23.2 22.5(25.43(87) 1/3.# See the page "Combination Table" 2.0 2.5(264) 18~30 / 16~30 24 SIC-39CV-D828-1 8 18 0.81(1170*315*173) 8.9) 9. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press.7) 1/4 (6.0) 0.8*8.5(653*641*216) 239/539 M:Metal. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Front Panel Color "#" Position kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) °C W AMNH096AP*1 2267(2638) 9000 2520(2929) 10000 7. Only for training and service purposes .# See the page "Combination Table" 2.197(5.8*8.52) 20 25.12C 2R.20C 1 22.4 (570*568*137) 11.W.12C 2R. D:Wood W A µF/Vac EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft Note : 1.43(87) 1/3.4*5.4 (570*568*137) 11.7) 13(28.White.0) 0.4*6.2*8.08 Turbo Fan 1/24. Indoor Unit Type Model Rated Cooling Capacity # Rated Heating Capacity # Air Circulation H/M/L Setting temperature range Fan motor Output Model No.0 (1030*290*153) 40.Product Specifications Indoor Unit Type Model Nominal Cooling Capacity # Nominal Heating Capacity # Air Circulation H/M/L Setting temperature range(cool/heat) Fan motor Output Model Fan Type No. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Connection Liquid Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity With(Without) S/Parts Front Panel Color "#" Position kcal/h(W) Btu/h kcal/h(W) Btu/h CMM(CFM) °C W AMNH07GDZ*0 AMNH09GDU*0 ARTCOOL DELUXE AMNH12GDU*0 AMNH18GD3*0 AMNH24GD3*0 EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft 1764(2051) 2267(2638) 3024(3515) 4536(5275) 5796(6740) 7000 9000 12000 18.4*15.4*15.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.500 5.6 (900*272*143) 40.5 2.5(300) 9.35) 3/8(9.1(17.0) 20 2R.81(1170*315*173)" "46.0) 0. All right reserved.9 (1117*377*225) "49.9) 13(28.7*25.13C 1.N:Walnut.32(617.2(1255*388*258)" 340/720 324/684 324/684 234/495 234/495 R:Mirror.4*6.276(7. B:Blue.52) 3/8(9.800 25.5(300) 18~30 / 16~30 24 SIC-39CV-D828-1 8 18 0.5(20.4*22.08 Turbo Fan 1/24.5(25.B:Blue. of Poles Input Running Current Capacitor Fan Type No.0) 19 19 19 20 20 2R.197(5.1*24.7 (985*363*220) 44.7) 1/2 (12.4) 1/4 (6.9 (1117*377*225) 44.3*8.12C 2R.6*11.24 - LGE Internal Use Only .0) 0.0 1.35) 3/8(9.35) 1/4 (6.7) 560/460/360 560/460/360 43 / 40 / 33 Thermistor 0.13C 2R.35) 3/8 (9.6*11. Due to our policy of innovation some specifications may be changed without notification.43(87) 1/3.74(95) 1/3.5(20.5(194) 8.4*6.M:Metal.35) 1/4 (6.7) 510/350/290 510/350/290 38 / 35 /32 Thermistor 0.9) 9.52) 20 25.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.4*6.35) 1/4 (6.3*10.197(5.2*8.000 2016(2343) 2520(2929) 3326(3867) 4990(5803) 6426(7472) 8000 10000 13200 19. Inc.3*10.35) 1/4 (6.7*5.52) 3/8(9.52) 1/2 (12.7*25.197(5.5(653*641*216) 239/539 ART COOL AMNH126AP*1 2772(3224) 12000 3049(3546) 13200 8.0) 20 2R.2 1. Copyright ©2007 LG Electronics.2(1255*388*258)" "49.1*24.32(617. 9*1.8 4/450 Turbo Fan 1/15.5*33.5*22.2 2.4*37.6) 3(6.6*14.3*18.3*7(860*390*190) Dimensions (W*H*D) Indoor inch(mm) Panel inch(mm) 41.3*18.5/440 2.7) 32 32 32 32 25.7) 1/2 (12.275(7) 0.2 *26.9) 19(41.1way AMNH096TCC0 AMNH126TCC0 AMNH126TEC0 Ceiling Cassette .5*22.9*1.x mm2 1/ 220~240/ 50 1/ 220~240/ 50 1/ 220~240/ 50 3.9) 26(126.2(670*670*30) 33.4 3 3.35) 1/4 (6.2(640*330*640) 25.5) 22(48.6*14.35 (1/4) 9.4) 570*265*570(22.35) 1/4 (6.275(7) 21 2R12C 4 33.5 22. Only for training and service purposes .4*1.2) 19(41.0(330) 1/13.9) 3(6.8 BLDC BLDC BLDC Turbo Fan Turbo Fan Turbo Fan 18.9/400 0.0*18.4*10.1 Ceilling Cassette .2(1050*480*30) 41.4*10.275(7) 0.5*1.4*1.7) 32 36.4 (570*269*570) 29.52 (3/8) 32/25 1.4*37.5 300/265/230 Direct Drive 2R x 11C x 18 570*265*570(22.5 IC-1630LGPJ 6 175 0.8*15.4*10.2*13.2(850*850*30) 19(41.2 *26.4*10.35) Piping Liquid inch(mm) 3/8(9.87 5.9) 24(52.67 2.5*1.5 Dehumidification Rate l/h 33.74 13200 19800 26400 0.56 Running Current A 0.0*11.275(7) Coil Tube Size (OD) inch(mm) 18 18 Fins per inch 2R11C 2R11C No.0*18.275(7) 0.35 0.4 22.4 (570*269*570) 22.35) 1/4 (6. of Poles 50 50 Input W 0.3 45 IC-9630LGAE IC-9630LGAC OBM-350292 OBM-401592 6 6 6 6 75 90 121 146 0. Used / Diameter EA/inch(mm) 900 / 800 / 700 1000 / 900 / 800 Fan RPM Cooling(H/M/L) rpm 900 / 800 / 700 1000 / 900 / 800 Heating(H/M/L) rpm 35 /32 / 28 37 / 33 / 29 Noise Level(Sound Press.4) 19(41.5 12/10/9 17/15/13 336/283/230 424/353/318 600/530/459 Direct Drive Direct Drive Direct Drive 2R x 11C x 18 2R x 11C x 18 2R x 9C x 18 570*265*570(22.93 10000 0. of Rows & Column 1.4) 670*30*670(26.35 (1/4) 6.75 4*0.75 Copyright ©2007 LG Electronics.5) 1/4 (6.4*26.4*13.52) 3/8(9.4) 670*30*670(26.8 7.5) Net Weight kg(lbs) 1/4 (6.4*10.7(1/2) 12.75 0.75 0.25 - LGE Internal Use Only .03 12000 18000 24000 3.1(980*255*460) Packing Dimension (W*H*D) inch(mm) 263/539 263/539 Stuffing Quantity Without S/Parts 20/40ft 3024(3515) 4536(5275) 6048(7033) 7056(8206) 12000 18000 24000 28000 3326(3867) 4990(5803) 6653(7736) 7761(9027) 13200 19800 26400 30800 11(353) 13(459) 15/14/13(53/494/459) 18(636) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18.4*26.52 5.9) 24(52.2(950*950*30) 32(70.4 X 1 22.2(850*850*30) 33.3(840*840*288) 37.8*36.56 0.4*32.35 (1/4) 9.4) 840*840*225 (33.0(382) 670 / 620 / 550 720 / 670 / 620 600/540480 660/590/530 670 / 620 / 550 720 / 670 / 620 600/540480 660/590/530 38 / 35 / 32 41 /39 / 37 43/41/39 44/41/39 Thermistor Thermistor Thermistor Thermistor 0.3 X 1 9.0*25.1m) H/M/L dBA Thermistor Thermistor Temperature controller 0.4 40.6*10.3*7(860*390*190) 33.2(1050*480*30) 22(48.0(382) 1/15. All right reserved.4 3 Fuse.0*25.35) 1/4 (6.4*1.52) 1/2 (12.64 9000 2.2 *26.6*10.5) 3(6.4 (744*292*744) 29.4way AMNH186TEC0 AMNH246TFC0 AMNH(C)306TFC0 AMNH(C)366TDC0 9072(10551) 36000 9979(11600) 39600 25/23/21(883/812/742) 18~30 / 16~30 52.6 (828*365*828) 189/378 189/378 84/168 84/168 Indoor Unit Type Model Power supply Cooling capacity Heating capacity Current Fan Nominal running current Motor type Fan type Motor output x Number of unit Air flow rate(H/M/L) Capacitor Drive Row x Column x FPI Body Decorative panel Body Decorative panel Ø/V/Hz kW Btu/h kW Btu/h A AMNH09GTEF0[MT10AH NE1] 1/ 220~240/ 50 2.3*11.5*22.3*11.1*8.52) Connection Gas inch(mm) 32 32 Drain hose (ID Ø) mm 38.4*1.9) 19(41.8) 670*30*670(26.5/6.2 2.6 (828*365*828) 32.28 7.2*13.275(7) 0.5/7.2 1.7(1/2) 32/25 32/25 32/25 1.4 (744*292*744) 26.Product Specifications Indoor Unit Type Model Rated Cooling Capacity # kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) mmAq °C W Ceiling Cassette .2(640*330*640) 32.4 X 1 40.9/400 Capacitor µF/Vac Cross Flow Fan Cross Flow Fan Fan Type 1/4(102) 1/4(102) No.0*33.7) 1/2 (12.4*1.35) 1/2 (12.2(670*670*30) 26.75 4*0.5*22.4) 950*950*30 (37.0(382) 550/510/470 550/510/470 40/38/36 Thermistor 0.5*29.4*1.5/440 4/440 4/440 Turbo Fan Turbo Fan Turbo Fan Turbo Fan 1/13.5*29.52 (3/8) 12.35 0.5/8/6.4 X 1 8.35 (1/4) 6. Inc.5*22.4*32.275(7) 19 19 21 21 2R11C 2R11C 2R12C 2R12C 1.9) 1/4 (6. Thermal Protector for Fan Motor Thermistor Thermistor Thermistor Thermistor R410A R410A R410A R411A LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD) LEV(in Outdoor unit or BD ) Multi F /F DX series Multi F /F DX series Multi F /F DX series Multi F /F DX series 4*0.75 4*0.4way AMNH12GTEF0[MT12AH NE1] AMNH18GTEF0[MT18AH NE1] AMNH24GTHF0[MT24AH NHO] cmm cfm µF/Vac mm mm(inch) mm kg(lbs) kg(lbs) dB(A)+3 mm(inch) mm(inch) mm l/h Coil Dimensions (WxHxD) Weight Air filter Sound level (H/M/L) Piping Liquid connections Gas Drain OD/ID Dehumidification rate Safety devices Temperature sensor Referigerant Referigerant control Connectable outdoor unit Power and transmission interunit cable No.35) 3/8(9.4*1.4(925*350*925) 30/64(36/72) 2267(2638) 3024(3515) 9000 12000 2520(2929) 3326(3867) Rated Heating Capacity # 10000 13200 9(317) 10(353) Air Circulation H/M/L External Static Pressure 18~30 / 16~30 18~30 / 16~30 Setting temperature range 14 14 Fan motor Output AMR-023E7 AMR-023E7 Model 4 4 No.1 38.6) Long Life Filter 33/29/24 6.6) 5(11) Long Life Filter Long Life Filter Long Life Filter 36/34/27 41/35/30 32/29/26 6.53 0.1*33.5*33.35 BLDC Turbo Fan 18.0(330) 1/15.8*15. 8*15.9*1. Used / Diameter EA/inch(mm) Fan RPM Cooling(H/M/L) rpm Heating(H/M/L) rpm Noise Level(Sound Press. of Rows & Column Dehumidification Rate l/h Dimensions (W*H*D) Indoor inch(mm) Panel inch(mm) Net Weight kg(lbs) Piping Liquid inch(mm) Connection Gas inch(mm) Drain hose (ID Ø) mm Packing Dimension (W*H*D) inch(mm) Stuffing Quantity Without S/Parts 20/40ft Copyright ©2007 LG Electronics.5) 1/4 (6. of Poles Input W Running Current A Capacitor µF/Vac Fan Type No.3*7(860*390*190) 41.35) 3/8(9.2(1050*480*30) 22(48.35) 3/8(9.52) 32 38. All right reserved.6*10.56 0.3*7(860*390*190) 41.2(1050*480*30) 22(48.Product Specifications Indoor Unit Type Model Rated Cooling Capacity # Rated Heating Capacity # kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) mmAq °C W AMNH09GTCC0 2267(2638) 9000 2520(2929) 10000 9(317) 18~30 / 16~30 14 AMR-023E7 4 50 0.9/400 Cross Flow Fan 1/4(102) 1000 / 900 / 800 1000 / 900 / 800 37 / 33 / 29 Thermistor 0.275(7) 18 2R11C 1. Inc.3*18.52) 32 38.0*18.2 33. Only for training and service purposes .9*1.26 - LGE Internal Use Only .0*18.1 263/539 Ceiling Cassette .3*18.5 33.56 0.8*15.1way AMNH12GTCC0 3024(3515) 12000 3326(3867) 13200 10(353) 18~30 / 16~30 14 AMR-023E7 4 50 0.1m) H/M/L dBA Temperature controller Coil Tube Size (OD) inch(mm) Fins per inch No.9/400 Cross Flow Fan 1/4(102) 900 / 800 / 700 900 / 800 / 700 35 /32 / 28 Thermistor 0.5) 1/4 (6.275(7) 18 2R11C 1.6*10.1(980*255*460) 263/539 Air Circulation H/M/L External Static Pressure Setting temperature range Fan motor Output Model No. Capacities are based on the following conditions: Cooling: .2*13.5 m .35 2.5m .# See the page "Combination Table" 2. 12C 1 1.5) 22(48.4 25.35) 3/8 (9.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.5/10/8.5) 29(63.2 2 25.6) 1/4 (6.4 IC-9630LGAE 6 75 0.5 4 18~30 118 IC-13450LG31A 4 180 4.276(7.6*9.8°F) WB .5m) Temperature controller Tube Size (OD) Coil Fins per inch No.1(650*230*535) 39.6 750*300*580(695*56.276(7. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Front Panel Color "*" Position kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) mmAq °C W AMNH096BTG0 AMNH126BTG0 Ceiling Concealed Duct AMNH186BTG0 AMNH096BPA0 2268(2637) 9000 2520(2930) 10000 11.9*24.31 0. Capacities are Net Capacities.4(OD) 845*370*760(735*90*435) 228/468 NOBEL WHITE W A µF/Vac EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft 2268(2637) 3024(3516) 4536(5274) 9000 12000 18000 2520(2930) 3326(3868) 4990(5802) 10000 13000 19800 8/7/6(282/246/211) 10/9/8(352/317/282) 13. Used / Diameter Noise Level H/M/L (Sound Press.276(7.4 (570*269*570) 26.0*21.1(650*230*535) 25.8(760*625*300) 172/356 172/356 123/251 - Note : 1.0*21.5 (750*80*750) 189/378(189/378) W A µF/Vac EA/inch(mm) dBA inch(mm) l/h inch(mm) inch(mm) kg(lbs) kg(lbs) inch(mm) inch(mm) inch(mm) inch(mm) inch(mm) 20/40ft Notes : 1.276(7.Product Specifications Indoor Unit Type Model Nominal Cooling Capacity# Nominal Heating Capacity# Air Circulation H/M/L Setting temperature range(cool/heat) Output Fan motor Model No.Indoor Temperature 27°C(80.8(760*625*300) 29. Due to our policy of innovation some specifications may be changed without notification.3 6/370 Sirocco Fan 1/Ø177 1125/990/870 1125/990/870 38/36/34 Thermistor 0.1*29.5/440 Turbo Fan 1/13.8(760*625*300) 29.35) 3/8 (9.4(OD) 845*370*760(735*90*435) 228/468 NOBEL WHITE AMNH126BPA0 3024(3516) 12000 3326(3868) 13200 11.0) 0.35) 1/4 (6.52) 25.52) 25.35) 3/8(9.0) 0.276(7.4 29.Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB . Inc.27 - LGE Internal Use Only .4 (670*30*670) 19(41.5/12/10(477/424/353) 2 2 2 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 35 35 47 YDK110-35-4L YDK110-35-4L YSK110-70-4L 4 4 4 68 68 126 0.4way AMNH096TEC0 2267(2638) 9000 2520(2929) 10000 9.0) 18 3R14C 2 750*300*580(695*56.8(197) 930/840/810 950/850/780 1000/900/800 930/840/810 950/850/780 1000/900/800 34/32/30 37/34/31 38/36/34 Thermistor Thermistor Thermistor 0.6*9. of Rows & Column Dehumidification Rate Indoor Unit Dimensions (W*H*D) Decorative Panel Body Net Weight Panel Liquid Piping Connection Gas Drain hose (ID Ø) Packing Dimension Indoor Unit (W*H*D) Decorative Panel Stuffing Quantity With(Without) S/Parts kcal/h(W) Btu/h kcal/h(W) Btu/h CMM(CFM) °C W Ceiling Cassette .Level Difference of Zero.8(197) 2/7. All right reserved.5*22.Interconnecting Piping Length 7.6*11.5/400 2.5/8/7(336/283/247) 18~30 / 16~30 18. Heating: .Level Difference of Zero.7) 25.5*396) 30(6) 1/4(6.1.3 6/370 Sirocco Fan 1/Ø177 1125/990/870 1125/900/870 38/36/34 Thermistor 0.5 4 18~30 118 IC-13450LG31A 4 180 4.5*396) 30(6) 1/4(6.2 22.0*25.0(330) 38 / 35 / 32 Thermistor 0. Due to our policy of innovation some specifications may be changed without notification.275(7) 19 2R11C 1.52) 1. of Poles Input Running Current Capacitor Fan Type No.4*9.6*11.35) 1/4 (6.5/10/8.6°F) DB /19°C(66.9*24.9) 3(6.4*10.58 2.Outdoor Temperature 35°C(95°F) DB /24°C(75. : See the page "Combination Table" Indoor Unit Type Model Rated Cooling Capacity Rated Heating Capacity Air Circulation H/M/L External Static Pressure Setting temperature range Fan motor Output Model No.4 25.52) 3/8 (9.6°F) DB / 6°C(42. 4.4*1.2 (640*330*640) "29.12C 2R.8(197) 1/7.52) 1/2 (12.Interconnecting Piping Length 7. 2.31 0.2°F) WB . Only for training and service purposes .12C 3R.9*24.0*21.2°F) WB .0) 18 18 18 2R.5/370 Sirocco Fan Sirocco Fan Sirocco Fan 1/7.0) 18 2R14C 1.2*26. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press.Outdoor Temperature 7°C(44.9) 1/4 (6.5/400 2.5*3. Copyright ©2007 LG Electronics. 3. of Poles Input Running Current Capacitor Type Fan No.26(32) "25.1(1000*230*535) 22(48.6*11.35) 3/8(9. 0 2.2) 38(83.7) 1/2(12.5*14.24*24.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.5(353/293/230) 135. of Poles Input Running Current Capacitor Fan Type No.5) 12(26. Due to our policy of innovation some specifications may be changed without notification.5/370 1.7*13.2*17.52) 3/8 (9.52) 1/2(12.2 (970*285*565) 38.97(177) 2/6. Copyright ©2007 LG Electronics.42 6/370 6/370 6/370 6/370 Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan 2/6.4/5.8*23.2 (970*285*565) 50*10.3 (900*200*490) 47.8*23.275(7) 0. All right reserved.88) 25.7(95) 1/3.2*11.35) 1/4(6.5 30 35 IC-18422LG31B IC-18422LG31A IC-9430LGCM IC-9430LGCM 4 4 4 4 35 43 53 63 0.21*8.2 2.35) 1/4(6.97(177) 1356/-/1270 1417/1350/1255 1415/1360/1290 1415/1360/1290 1356/-/1270 1417/1350/1255 1415/1360/1290 1415/1360/1290 36/34/32 37/35/33 40/38/36 42/40/38 Thermistor Thermistor Thermistor Thermistor 0. Only for training and service purposes .1(80) 1/3.23 0.0(1435*375*585) 120/252 120/252 95/191 95/191 Ceiling & Floor(Convertible) AMNH126VEA0 AMNH186VBA0 AMNH246VBA0 W A µF/Vac EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft 2268(2637) 3024(3516) 4536(5274) 6048(7032) 9000 12000 18000 24000 2520(2930) 3326(3867) 4990(5801) 6350(7384) 10000 132000 19800 25200 7.3 3.24*24.92 0.5/370 1.35) 1/4 (6.4(OD) 25.0(1135*340*585) 44.4*23.1(80) 960/870/760 1240/1120/900 1090/990/890 1160/1060/960 960/870/760 1240/1120/900 1090/990/890 1160/1060/960 36/32/28 40/36/31 43 / 40 / 37 45 / 42 / 39 Thermistor Thermistor Thermistor Thermistor 0.2*17.5(1130/1024/936) 8 8 8 8 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 118 118 124 272 IC-13450LG13C IC-13450LG13C IC-13450LG13J IC-13450LG13A 4 4 4 4 180 180 250 323 0.Product Specifications Indoor Unit Type Model Rated Cooling Capacity Rated Heating Capacity Air Circulation H/M/L External Static Pressure Setting temperature range Fan motor Output Model No. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Indoor Unit Type Model Rated Cooling Capacity Rated Heating Capacity Air Circulation H/M/L External Static Pressure Setting temperature range Fan motor Output Model No.92 1.7) 5/8(15.5*14.3 (900*200*490) 35.275(7) 0.7 (880*260*450) 34.197(5) 0.4(OD) 25.6*10.1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.28 - LGE Internal Use Only .275(7) 21 21 21 21 3R10C 3R10C 3R 12C 3R 12C 2.7(1180*298*450) 46.9*27(1272*278*686) 189/383 189/383 102/219 102/219 Note : 1.5/14(636/583/494) 28/25/23(989/883/812) 32/29/26. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID Ø) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) mmAq °C W AMNH096VEA0 kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) mmAq °C W AMNH186BHA0 Ceiling Concealed Duct AMNH(C)246BHA0 AMNH(C)306BGA0 AMNH(C)366BGA0 W A µF/Vac EA/inch(mm) rpm rpm dBA inch(mm) l/h inch(mm) kg(lbs) inch(mm) inch(mm) mm inch(mm) 20/40ft 4536(5275) 6048(7034) 7560(8792) 9072(10551) 18000 24000 30000 36000 4990(5803) 6653(7737) 8316(9671) 9979(11606) 19800 26400 33000 39600 16.9*19.5/370 1.4*23.2*22.7*13.35) 1/4(6.97(177) 2/6.5/12(530/477/424) 18-30/16-30 18-30/16-30 18~30 / 16~30 18~30 / 16~30 14.275(7) 0.23 0.0/8.18 0.2 35.4*11.6*10.35) 1/2(12.3/6.0(276/226/177) 10.2*11.97(177) 2/6./12/11(477/424/388) 15/13.07(1200*615*205) 12(26.5 17.5/370 Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.8/6.4*11. Inc.4*7.21*8.35) 1/4(6.07(1200*615*205) 47.4*7.8) 38(83.27 1.7 (880*260*450) 46.1) 30(66.7*17. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press.7(1180*298*450) 35(77.1 1.88) 5/8(15.8) 1/4(6.197(5) 0. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press.2) 35(77.275(7) 0.1) 1/4 (6.7) 1/2(12.5/14.5) 30(66.4(OD) 25.275(7) 20 20 18 20 2R 12C 2R 12C 2R 12C 2R 14C 1 1.# See the page "Combination Table" 2.7*17.0(1435*375*585) 18.0(1135*340*585) 18.35) 3/8 (9.7) 20 20 20 20 38.7(95) 1/3.5 3 3.4(OD) 44.5/13(583/512/459) 18/16.2*22. of Poles Input Running Current Capacitor Fan Type No.9*19.9*27(1272*278*686) 50*10.5 34.35) 1/4(6. Only for training and service purposes .35(1/4) 6.29 - LGE Internal Use Only .400 Induction Sirocco fan 17/15/13.000 3.64) 820*190*575(32.48*22.7(1/2) 12. Inc.x mm2 Direct Drive Direct Drive Direct Drive Direct Drive 2R x 12C x 21 2R x 12C x 21 2R x 11C x 21 3R x 10C x 18 820*190*575(32.28*7.5 Fuse.0 1.Product Specifications Indoor Unit Type AMNH09GB1A0 [MB09AHL N10] Ø/V/Hz kW Btu/h kW Btu/h Cooling 1/220~240/50 2.7(1/2) 32/20 32/20 32/20 32/20 1.5/7.100*190*575(43.5/8.5 300/265/230 Ceiling Concealed Duct .800 Induction Sirocco fan 15/13.93 10.52 12.000 2.5/11.28*7.3*7.64) 1.27 18.48*22.87 13.5 530/477/406 AMNH24GB2A0 [MB09AHL N20] 1/220~240/50 7.35(1/4) 9.5 600/530/477 Model Power Supply Cooling Capacity Heating Capacity Current Fan Nominal Running Current Motor Type Fan Type Motor Output x Number of Unit Air flow rate(H/M/L) External Static Pressure Capacitor Drive Row x Columns x FPI Body Body H/M/L Liquid Gas Drain(Out diameter) Coil Dimensions(WxHxD) Weight Air filter Sound level(H/M/L) Piping Connections Dehumidification Rate Safety devices Temperature sensor Referigerant Referigerant control Connectable outdoor unit power and transmission interunit cable No.48*22.03 24.6) 20.44 26.80 19.6) 1.5(45.2 2.52(3/8) 9.5/6. All right reserved.000 Induction Sirocco fan cmm cfm mmAq µF/Vac mm mm(inch) kg(lbs) dBA mm(inch) mm(inch) mm l/h 8.5(45.75 4*0.100*190*575(43.75 Copyright ©2007 LG Electronics.1) Long Life Filter Long Life Filter Long Life Filter Long Life Filter 31/26/25 33/31/26 34/31/29 36/34/32 6. Thermal Protector for Fan Motor TherMistor TherMistor TherMistor TherMistor R410A R410A R410A R410A LEV(In Outdoor unit or BD) LEV(In Outdoor unit or BD) LEV(In Outdoor unit or BD) LEV(In Outdoor unit or BD) Mult F/F DX series Mult F/F DX series Mult F/F DX series Mult F/F DX series 4*0.35(1/4) 6.5/7.000 5.5 336/300/265 AMNH18GB2A0 [MB18AHL N20] 1/220~240/50 5.000 7.64 9.2) 20.5 (65) 30(66.52(3/8) 12.75 4*0.3*7.2) 29.35(1/4) 6.75 4*0.000 Induction Sirocco fan 9.0 2.Low Static AMNH12GB1A0 [MB12AHL N10] 1/220~240/50 3.48*22. Indoor Temperature 27°C(80.5 50 25 15 7.0) 18 1R. Due to our policy of innovation some specifications may be changed without notification.75 (Includes earth) 4*0.52)*2EA 34.3 (1020*870*440) 40.Level Difference of Zero.220~240.276(7.8*12.3 (1020*870*440) 40. Fan Motor Model Output Capacitor Fan Type No.3*31.97) at 7.75 (Includes earth) 4*0.28C IC28640LG28S 120 6/370 Propeller 1/18. Copyright ©2007 LG Electronics.0) 18 2R.2~15.5 54/114 28 1.5 54/114 28 1.1(460) Side Discharge 49(1730) 51/48 Invertion cycle 1/4 (6. 2.440 4600~28800 1210~8063 1407~9376 4800~32000 A4UW306FA0 1159~9072 1348~10549 4600~36000 2116~10332 2461~12014 8.6 (870*800*320) 52(115) 3*3.* mm2 m m m m inch(mm) 20/40ft EA/inch(mm) Side / Top CMM(CFM) dBA µF/Vac W inch(mm) g(oz). .0~5.52)*2EA 34.3*31.5*12. Inc.5*12.36C IC28640LG28J 130 6/370 Propeller 1/18.48C IC9625LGSY 65 * 2 2.6(870*655*320) 81/171 A3UW246FA0 1159~7257 1348~8.6~12.2*17.5~11.0) 18 2R.6 (870*1038*320) 4*0.220~240.5/4~12 1 1.220~240.97) at 7.6(870*655*320) 81/171 A2UW146FA1 1159~4031 1348~4688 4600~16000 1210~4535 1407~5274 4800~18000 1.L.18) at 7.5m R-410A L.0/370 Propeller 2/16.3*31.5/2.52)*3EA 34.220~240.6~6.9 3.V 0. type Cooling/Heating Cooling/Heating Cooling/Heating W A A Ø.6 (870*800*320) 57(125.5*12.1(460) Side Discharge 53(1872) 51/48 Invertion cycle 1/4 (6.5 40 25 15 7.6 (870*800*320) 75(165) 3*3.2*17.7/4.08~13.08~13.28C 120 6/370 Propeller 1/18.Hz % % A2UW146FA0 1159~4031 1348~4688 4600~16000 1210~4535 1407~5274 4800~18000 1.1(460) Side Discharge 49(1730) 50/47 Invertion cycle 1/4 (6.2*25.78) at 7.5m R-410A L.5 34.P Type(model name) Charge Type Control Coil Tube Size (OD) Fins per inch No.6(870*655*320) 81/171 A3UW186FA0 1159~5443 1348~6330 4600~21600 1210~6249 1407~7268 4800~24800 3.52)*3EA 34.L.Product Specifications Outdoor Unit .28C 120 6/370 Propeller 1/18.2°F) WB Heating: .0) 18 2R.E.1*34.5m R-410A L.3*31.1*34.276(7.28C 120 6/370 Propeller 1/18.75 (Includes earth) 4*0.E.V 0. 3.5*12.V 0.5m R-410A L.75 (Includes earth) Packing Dimension (W*H*D) 40.220~240.35)*4EA 3/8 (9.Outdoor Temperature 7°C(44.2*25.2*17.E.V 0.Multiple piping models Model Cooling Capacity # kcal/hr W Btu/hr Heating Capacity # kcal/hr W Btu/hr Input # Running Current # Starting Current Power Supply Power Factor Max.E.000 380~1450/450~1350 380~1450/450~1350 420~2400/480~2600 420~2400/480~2600 440~2970/560~2950 440~2970/560~2950 450~3580/620~3580 3.6°F) DB / 6°C(42.E.52)*4EA 84(185) 3*2. All right reserved.52)*2EA 34.P Type(model name) Type O.6~6.6°F) DB /19°C(66.6 (870*800*320) 52(115) 3*3.75 (Includes earth) 4*0.1(460) Side Discharge 49(1730) 50/47 Invertion cycle 1/4 (6.1*34.75 (Includes earth) 4*0.5 70 25 15 7. Only for training and service purposes .6 (870*808*320) 34.276(7.50 94~98 4 e-Scroll Rotary 1950(68.9 3.5m R-410A L.97) at 7.35)*3EA 3/8 (9. Used / Diameter Discharge Air Circulation Noise Level(Sound Press.8 1 1.5~11.3*31.Interconnecting Piping Length 7.2*25.6(870*655*320) 81/171 A2UW186FA0 1159~5443 1348~6330 4600~21600 1210~6249 1407~7268 4800~24800 3.0~5.5m R-410A L.V 0.5/4~12 1 1.2*25.6 (870*808*320) 75(165) 3*2. Capacities are based on the following conditions: Cooling: .Outdoor Temperature 35°C(95°F) DB /24°C(75.5 40 25 15 7.276(7.220~240.Interconnecting Piping Length 7.V 0.Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB .75 (Includes earth) 4*0.97) at 7.3*31.V 0.6~12.50 94~98 2 e-Scroll 1650(59.400~41.5 34.35)*3EA 3/8 (9.8*12.1m) Defrosting SVC Valve Dimensions (W*H*D) Net Weight Power Supply Cable Interunit Cable Max.276(7.0) 18 2R.1(460) Side Discharge 49(1730) 51/48 Invertion cycle 1/4 (6.220~240.6~15.35)*2EA 3/8 (9.50 94~98 2 Rotary 1650(59.2°F) WB .Level Difference of Zero.36C IC28640LG28J 130 6/370 Propeller 1/18. of Rows & Column/No. Interunit Piping Length Max.5/2.3*31.50 94~98 3 e-Scroll Rotary 1950(68.E.1(460) Side Discharge 53(1872) 51/48 Invertion cycle 1/4 (6.78) at 7.5*12.52)*4EA 75(165) 3*2.0/4. Number of Connectable Indoor Units Compressor (Invertor) Compressor (Constant) Refrigerant Type O.5 40 25 15 7.0/4.0) 18 2R. # : See the page "Combination Table" 4.5*12. Installation Height Difference Stuffing Quantity Total of Each Room For One Room Indoor Unit~Outdoor Unit Indoor Unit~Indoor Unit Without S/Parts Liquid Gas inch(mm) inch(mm) inch(mm) kg(lbs) No. Capacities are Net Capacities.V.7 28 1.8°F) WB .5 34.5 34.5*12.0) 18 1R.6) 3*3.35)*2EA 3/8 (9.276(7.5 40 25 15 7.276(7.5m R-410A L.50 95~98 4 e-Scroll Rotary INTERNAL 2500(88.5(420) Side Discharge 31(1094)*2 50/46 Invertion cycle 1/4 (6.8*12.8 1 1.30 - LGE Internal Use Only .5 51/111 MRA99150-9090 MRA99150-9090 IC28640LG28S IC28640LG28S IC28640LG28S 34.8*12.440 4600~28800 1210~8063 1407~9376 4800~32000 A4UW246FA0 1159~7257 1348~8.5 50 25 15 7.E.5m .5 m .35)*2EA 3/8 (9.50 94~98 2 e-Scroll 1650(59.35)*4EA 3/8 (9.3 (1045*1140*440) Notes: 1.* mm2 No.50 94~98 3 e-Scroll 1650(59. V 0.3*21.3*25.E.9 Starting Current Cooling/Heating 8 Power Supply 1.2°F) WB Heating: .Multiple piping models Model A2UW146FA2 Cooling Capacity# 4600-14000-16000 1348-4100-4688 1159-3526-4031 Heating Capacity# 4800-16000-18000 1407-4700-5274 1210-4042-4535 Input# Cooling 380-1280-1500 Heating 450-1220-1262 Running Current# Cooling 1.E.2(920*580*360) AMNH126LRL0+AMNH126LRL0 144/312 A2UW166FA1 4600-16000-17500 1348-4688-5128 1159-4031-4410 4800-18000-19500 1407-5274-5714 1210-4535-4914 380-1380-1600 450-1400-1550 1.2*22.1(460) Side Discharge 53(1766) 55 Invertion cycle 1/4 (6.75 (Includes earth) Max.50 94~98 3 Twin Rotary GKT141NAA Synchronous Reluctance Motor 1 1451 570 FVC68D 1550(54.6) 3*2. Used / Diameter EA/inch(mm) 1/16.9-10.0/400 Propeller 1/16.V 0.75 (Includes earth) 70 25 15 7.2*22. .Outdoor Temperature 35°C(95°F) DB /24°C(75.5 36.V 0.28C IC28640LG28S 120 6/370 Propeller 1/18.50~60 94~98 4 Rotary 5KD240XCA21 DC Brushless Motor 1 2405 900 FV50S CS-7L N115 2000(70.3 8 1.Level Difference of Zero.4-7.E.5 4*0.5(420) Discharge Side / Top Side Discharge Air Circulation Outdoor CMM(CFM) 35(1236) Noise Level(H/L) Sound Press.5 m . 2R.5 40.220~240.7) "at 7.9 Heating 2.1(460) Side Discharge 53(1766) 55 Invertion cycle 1/4 (6.276(7.0) 18 2R. Capacities are based on the following conditions: Cooling: .5m" R410A L.35)*2EA 3/8 (9.V Coil Tube Size (OD) inch(mm) 0.52)*2EA 34.5 Packing Dimension W*H*D inch(mm) 36.P Type(model name) Refrigerant charge Charge g(oz) 950(33.E.8°F) WB .6 (870*655*320) 52(115) 3*2.7-6.50 94~98 2 Scroll 5CS130X DC Brushless Motor 1 1405 480 RB68A 950(33.Product Specifications Outdoor Unit . Capacities are Net Capacities.E.5(420) Side Discharge 35(1236) 51 Invertion cycle 1/4 (6. 3.3*10 (770*540*245) 37(81.24C OBM-3018P2 47 2.220~240. Inc.3*31.1-6.3*10 (770*540*245) 37(81.276(7.5m" R410A L.276(7.3*21.5) "at 7.52)*2EA 30. Due to our policy of innovation some specifications may be changed without notification.5 4*0.4-7.3-7.36C SIC-72FW-F1124-3 124 Propeller 1/18.P Type(model name) "Compressor(Constant)" Type Model Motor Type Quantity Ea Motor Input W Oil Charge cc Oil Type O.3*31.1(460) Side Discharge 53(1766) 51/45 Invertion cycle 1/4 (6.2°F) WB .5m" R410A L.35)*2EA 3/8 (9. 2.3 2.35)*2EA 3/8 (9.75 (Includes earth) 30 20 15 7. Installation Indoor Unit~Outdoor Unit m 15 Height Difference" Indoor Unit~Indoor Unit m 7.5) "at 7.Outdoor Temperature 7°C(44.7-6.50 Power Factor 94~98 Max.1 8 1.5cm" R410 L.5 4*0.52)*3EA 34.3*10 (770*540*245) Net Weight Outdoor kg(lbs) 37(81.220~240.7-6.6 (870*800*320) ? 3*2.5(420) Side Discharge 35(1236) 51 Invertion cycle 1/4 (6.276(7.0/400 Propeller 1/16. Only for training and service purposes . Copyright ©2007 LG Electronics.35)*2EA 3/8 (9.E.5cm" R410 L.V 0.3-7.6°F) DB /19°C(66.7-5.5 36.220~240.8*14.V.0) Fins per inch 18 No.2*22.75 (Includes earth) 70 25 15 7. Number of Connectable Indoor Units 2 "Compressor(Inverter)" Type Rotary Model 5RS102XAA Motor Type DC Brushless Motor Quantity Ea 1 Motor Input W 980 Oil Charge cc 320 Oil Type RB68A O.5 4*0.52)*2EA 34.276(7.0) 18 2R.V 0.5 Interunit Cable 4*0.50 94~98 2 Twin Rotary GKT141NAA Synchronous Reluctance Motor 1 1451 570 FVC68D 950(33.4 2.0) 18 2R.5 Notes: 1.Indoor Temperature 27°C(80.9-6.2(920*580*360) AMNH126LRL0+AMNH126LRL0 144/312 A3UW186FA1 4600-18000-21600 1348-5300-6329 1159-4558-5443 4800-21600-24800 1407-6300-7268 1210-5418-6249 480-1550-2350 550-1650-2320 2.3-10.220~240.31 - LGE Internal Use Only .3-6.1-5.L.5m" Type R410A Control L.5m . All right reserved.52)*2EA 30.L.36C SIC-72FW-F1124-3 124 Propeller 1/18.3 (1020*715*440) AMNH096LRL0*2 + AMNH126LRL0 0 A4UW24GFA0 A4UW30GFA0 1.220~240.50~60 94~98 4 Rotary 5KD240XCA21 DC Brushless Motor 1 2405 900 FV50S CS-7L N115 2000(70.0) 18 2R.5*12.5) "at 7.24C OBM-3018P2 47 2.2(920*580*360) Testing Combinations AMNH096LRL0+AMNH126LRL0 Stuffing Quantity 20/40ft 144/312 Btu/hr W kcal/hr Btu/hr W kcal/hr W W A A A Ø.35)*2EA Gas 3/8 (9.Hz % A2UW166FA0 4600-16000-17500 1348-4688-5128 1159-4031-4410 4800-18000-19500 1407-5274-5714 1210-4535-4914 380-1380-1600 450-1400-1550 1.75 (Includes earth) 40 25 15 7.6-7.1-6.Interconnecting Piping Length 7.2*28.1m dB(A)±1 51 Defrosting Invertion cycle SVC Valve Liquid inch(mm) 1/4 (6.3*21.35)*3EA 3/8 (9. of Rows & Column/No.5) "at 7.8*14.Interconnecting Piping Length 7.276(7.5 4*0. Interunit Piping Length Total of Each Room m 30 For One Room m 20 "Max.5 1.*mm2˜ 3*2. # : See the page "Combination Table" 4.52)*2EA Dimensions W*H*D inch(mm) 30.6) 3*2.8*12.Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB .6°F) DB / 6°C(42.1 8 1.5) "at 7.0/400 Fan Type Propeller No.6 (870*800*320) ? 3*2.0) 18 2R.5*12.Level Difference of Zero.8*14.3 2.6) Power Supply Cable No.1*17.75 (Includes earth) 30 20 15 7.24C Fan motor Model OBM-3018P2 Output W 47 Capacitor µF/Vac 2. 4) "at 5m" R410A L.5 m .220~240.3 43 1.5*28.512*730) 148(326) 3*5. Capacities are Net Capacities.75 (Includes earth) 100 50 50 15 30 10 41.4~26.05) 31.5(420) Side Discharge 31(1094)*2 50/46 Invertion cycle 1/4 (6.05) 31.E.1(460) Side Discharge 53(1872) *2 58/54 Invertion cycle 3/8 (9. of Rows & Column/No.7(526) Top Discharge 90(3179) 59/56 Invertion cycle 3/8 (9.48C IC9625LGSY 65 * 2 2.2°F) WB .50 90 ~ 97 7 e-Scroll Rotary Internal Rotary Internal 7100(250. Copyright ©2007 LG Electronics.32 - LGE Internal Use Only .550*730) 20/42 Heating Capacity # Input # Cooling/Heating Running Current # Cooling/Heating Starting Current Cooling/Heating Power Supply Power Factor Max.L.Distributor type models Model Cooling Capacity # Btu/h W kcal/h Btu/h W kcal/h W A A Ø.9~22. Installation Indoor Unit~Outdoor Unit Height Difference Indoor Unit~Indoor Unit Packing Dimension W*H*D Stuffing Quantity Without S/Parts g(oz) inch(mm) W µF/Vac EA/inch(mm) Side / Top CMM(CFM) dB(A)±1 inch(mm) inch(mm) inch(mm) kg(lbs) No.7 (806*1.E.P Type(model name) Compressor Type (Constant-1) O. .5m .1*34.0*28.L.0) 18 2R.7*59.276(7.0/370 Propeller 2/16. Interunit Total Piping Piping Length Total Main Piping Total Branch Piping For One Room Max.75 (Includes earth) 120 50 70 15 30 10 33. All right reserved.0) 18 2R.5 (900*1.52C IC28640LG28J 120 * 2 6/370 Propeller 2/18.V.276(7.P Type(model name) Compressor Type (Constant-2) O.18) at 5m R-410A L.E.276(7.88) 34.2°F) WB Heating: .220~240.50 91 ~ 98 6 e-Scroll Rotary Internal 4100(144.V 0.53C*2 ARE676E01 270 10/370 Propeller 1/20.000 450~3580/620~3580 3.7*48.512*730) 142(312) 3*5.0) 18 2R. Fan motor Model Output Capacitor Fan Type No.220~240.0) 18 2R.75 (Includes earth) 65 15 50 15 15 7.3(1060*1220*465) 27/55 A7UW486FA0 5000~57600 1465~16878 1260~14515 5800~63600 1700~18636 1462~16027 750~5800/1450~5430 3.6°F) DB /19°C(66.Outdoor Temperature 7°C(44.0/4.0 4*0.* mm2 m m m m m m inch(mm) 20/40ft Notes: 1.6 (870*1038*320) 84(185) 3*2.6/7.52) 3/4 (19.7 (806*1.9*61.4*45.V 0.75 (Includes earth) 110 50 60 15 30 10 33.5*12. Capacities are based on the following conditions: Cooling: .2*17.E.0*18.400~41.5 4*0.4~29.9*61.Level Difference of Zero. Only for training and service purposes .1m Defrosting SVC Valve Liquid Gas Dimensions W*H*D Net Weight Outdoor Power Supply Cable Interunit Cable Max.V 0.6°F) DB / 6°C(42.5*28.7/4.Outdoor Temperature 35°C(95°F) DB /24°C(75. Used / Diameter Discharge Air Circulation Outdoor Noise Level(H/L) Sound Press.Level Difference of Zero.7*59.Hz % A4UW306FA1 1159~9072 1348~10549 4600~36000 2116~10332 2461~12014 8.8*14.7(526) Top Discharge 90(3179) 59/56 Invertion cycle 3/8 (9.Interconnecting Piping Length 7.5 67 1.5 40.05) 35.35) 5/8(15.P Type(model name) Refrigerant charge Charge Type Control Coil Tube Size (OD) Fins per inch No.0/6.0 4*0.7 28 1.0*28.6~21.L. 2.53C*2 ARE676E01 270 10/370 Propeller 1/20.7(860*1.Product Specifications Outdoor Unit .V 0. Number of Connectable Indoor Units Compressor Type (Invertor) O.6~15.165*370) 105(231) 3*5.6) "at 5m" R410A L.5 74 1.* mm2 No.Interconnecting Piping Length 7.50 90 ~ 97 8 e-Scroll Rotary Internal Rotary Internal 7100(250.52) 3/4 (19.1~30. Due to our policy of innovation some specifications may be changed without notification.4) "at 5m" R410A L. 3. # : See the page "Combination Table" 4.7(860*1.3*31.220~240.550*730) 20/42 A8UW566FA0 5000~67200 1465~19691 1260~16934 5800~75600 1700~22152 1462~19051 750~6600/1550~6800 3. Inc.52) 3/4 (19.6~24.0 4*0.276(7.2~15.50 95~98 4 e-Scroll Rotary INTERNAL 2500(88.8°F) WB .3 (1045*1140*440) 51/111 A6UW406FA0 5000~48000 1465~14067 1260~12095 5500~53000 1612~15533 1386~13356 600~4980/950~4810 2.Indoor Temperature 27°C(80.Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB . 220~240/220V Ø1 .6*8.75 (Includes earth) 3/8 (9.10m Set up the BD unit and Indoor Unit in 15m.6*8.88)*2EA - 4 8 1 Note : 1.05) 1/4 (6.8(422*202*300) 5.6*9.220~240/220V 10 0. BD unit or Indoor Unit Max. 50/60Hz . Only for training and service purposes .0 4*0.8 4*0. 2. * mm2 inch(mm) inch(mm) inch(mm) inch(mm) m m 1~4 7k/9k/12k/18k/24k Paintingless Ø1 . (If need.Max.0 4*0.75 (Includes earth) 4*0. * mm2 No.Product Specifications LG Branch Distributor Connectable Indoor Units Casing color Powre Source Power Consumption Runing Current Dimensions Packing Dimension Net Weight Connecting Cable Piping Connection (To Outdoor Unit) Piping Connection (To Indoor Unit) Piping length Piping Elevation Drain hose Heat Insulation Accessories Model Number of Indoor Units Capacity PMBD3640 PMBD3630 PMBD3620 PMBD7230 Btu/h W*H*D W*H*D Direction Indoor Unit Direction Outdoor Unit Liquid Gas Liquid Gas W A inch(mm) inch(mm) kg No.8(422*202*300) 4.35)*4EA 3/8 (9. Copyright ©2007 LG Electronics.6*8. 50/60Hz .05) 3/4(19.52) 3/8 (9.75 (Includes earth) 4*0.0*11.05 11.9(302*143*252) 16.33 - LGE Internal Use Only .52)*3EA 3/8 (9.220~240/220V 10 10 0.9*5.05 11.35)*3EA 1/2 (12.05) 1/4 (6.9(302*143*252) 16.6*9. The BD should be installed inside the building.52)*4EA - Hanger Screw Manual EA EA EA 4 8 1 1~3 1~2 7k/9k/12k/18k/24k 7k/9k/12k/18k/24k Paintingless Paintingless Ø1 .05) 1/4 (6.9(302*143*252) 16. Height .52)*2EA Unusable Both Liquid and Gas pipes 4 4 8 8 1 1 1~3 18k/24k/30k/36k Paintingless Ø1 .35)*2EA 3/8 (9.8(422*202*300) 16.8(422*202*300) 5. use the connector which is included in the indoor unit) 3.220~240/220V 10 0.9 4.75 (Includes earth) 3/8 (9. 50/60Hz .BD unit or Indoor Unit Min.7).05 0. Height .75 (Includes earth) 4*0.9*5. Inc.0*11.6*9.52) 3/4(19. 3/8 (15.05 11.0*11. All right reserved. 50/60Hz .35)*3EA 1/4 (6.6*9.52) 3/4(19.6*8.9(302*143*252) 11.75 (Includes earth) 4*0.75 (Includes earth) 3/8 (9.75 (Includes earth) 4*0.9*5.0*11.52) 3/4(19. The piping connection must be suit the piping sizes of the indoor unit which will be connected.9*5. Art Cool Type Indoor Unit • Do not have any heat or steam near the unit. • A place where air circulation in the room will be good. fence. allowing a minimum of 10cm from ceiling.Installation Installation Read completely. Only for training and service purposes . Connecting cable Drain hose 2. • Make sure that condensation drainage can be conveniently routed away. then follow step by step. • Ensure the spaces indicated by arrows from the wall. Split Type Indoor Unit • There should not be any heat source or steam near the Front Left Rear left Down right Right Rear right unit. ceiling. Do not install near a doorway. The unit should be installed as high on the wall as possible. • Use a stud finder to locate studs to prevent unnecessary damage to the wall. • A place where noise prevention is taken into consideration. • Select a place where there are no obstacles in front of the unit. • Ensure that the space around the left and right of the unit is more than 50cm. All right reserved. or other obstacles. • A place where drainage can be easily obtained. Select the best location of indoor unit 1.34 - LGE Internal Use Only . • There should not be any obstacles to prevent the air circulation. Inc. More than 10cm More than 50cm More than 50cm More than 2m Copyright ©2007 LG Electronics. • Do not install the unit near the door way. • There should not be any obstacles to the air circulation.) • The place shall easily connect with the outdoor unit. Duct Type Indoor Unit Install the air conditioner in the location that satisfies the following conditions. • The indoor unit must have the maintenance space around. • Do not install the unit near the door way. • Make sure that condensation drainage can be conveniently routed away. Ceiling Board 30 or less Unit:cm 100 or more Copyright ©2007 LG Electronics. • The place where air circulation in the room will be good . • The place shall be able to inspect the unit as the figure. • The place shall allow easy water drainage. 4. • The place where the unit is not affected by an electrical noise. 600 1000 Top view (unit: mm) Inspection hole (600X600) Control box • The place where the unit shall be leveled. • Ensure that the space around the left and right of the unit is more than 20cm.3m CAUTION Install the indoor unit on the wall where the height from the floors more than 2. • There should not be any heat source or steam near the unit 600 Front Front view H 5. allowing a minimum of 30cm from ceiling. • Select a place where there are no obstacles in front of the unit. Do not install near a doorway. Inc. • Ensure the spaces indicated by arrows from the wall. or other obstacles. Only for training and service purposes .(Suitable dimension “H” is necessary to get a slope to drain as figure. • The place shall easily bear a load exceeding four times the indoor unit’s weight.35 - Above 250 330 or less 50 or more Floor LGE Internal Use Only . CST Type Indoor Unit • There should not be any heat source or steam near the unit.Installation 3. The unit should be installed as high on the wall as possible.3 meters. • Use a stud finder to locate studs to prevent unnecessary damage to the wall. Art Cool Deluxe Type Indoor unit • Do not have any heat or steam near the unit. All right reserved. More than 30cm More than 20cm More than 30cm More than 2. ceiling. 50 or more Ceiling Ceiling Board 30 or more • A place where drainage can be easily obtained. • A place where air circulation in the room will be good. • A place where noise prevention is taken into consideration. • A place where drainage can be easily obtained. • There should not be any obstacles to prevent the air circulation.36 - LGE Internal Use Only . ceiling. R More than 20cm More than 20cm R More than eye-level More than 20cm (Ceiling installation) More than 20cm (Floor/Wall installation) Copyright ©2007 LG Electronics. All right reserved. CVT Type Indoor Unit • There should not be any heat source or steam near the unit.Installation 6. • Do not install the unit near the door way. • Ensure the spaces indicated by arrows from the wall. • A place where noise prevention is taken into consideration. Inc. or other obstacles. • A place where air circulation in the room will be good. Only for training and service purposes . Inc. Only for training and service purposes . 2) Drill the piping hole with 70mm dia. Installation Plate Type "A" screw Weight marking-off line Thread The lower left and the right side of Installation Plate C Installation plate D Ø70mm A Right rear piping Left rear piping CHASSIS (Grade) SQ(7/9k) SR(9/12k) ST(18/24k) Distance(mm) A 75 0 105 B 12 40 0 C 80 20 210 D 12 40 0 D C Left rear piping Installation plate A B Ø70mm Right rear piping CHASSIS (Grade) S4 SE S5 Distance (mm) A 50 65 95 B 105 110 122 C 59 85 235 D 105 110 122 Copyright ©2007 LG Electronics. All right reserved. • Line according to the arrows marked on lower the left and the rght side of the Installation Plate.Installation How to fix 1.) • Always mount the Installation plate horizontally by aligning the marking-off line by means of the thread and a level. consider using anchor bolts. (If mounting the unit on the concrete wall. Room Type Indoor Unit Installation The mounting wall should be strong and solid enough to protect it from the vibration. • Drill the piping hole at either the right or the left and the hole should be slightly slant to the outdoor side. The meeting point of the extended line is the center of the hole. holecore drill. 1) Mount the installation plate on the wall with four Type "A" screws.37 - LGE Internal Use Only B Ø70mm Ø70mm . and join drain hose and connecting hose. CAUTION: After removing the pipe hole. • As the following picture. Only for training and service purposes . and separate connecting wire with product. cut the burr for safety. • The moment of lifting the both lower parts of panel front. All right reserved. and close grille bottom again. you can hear sound this panel came out. 2) Cover pipe and cover side remove • Remove two screws(for fixing cover pipe) • Pull up the cover side of desired connecting direction.38 - LGE Internal Use Only . Pipe hole NOTE: When connecting pipe path through rear wall. In this time panel front is separated • After pull down this panel a bit. Panel Front Connector Copyright ©2007 LG Electronics. then remove screws (2 pieces). path through the hole of cover side. 3) Drain hose junction • Remove the rubber stopple of desired drain direction. Art Cool Type Indoor Unit The wall you select should be strong and solid enough to prevent vibration 1) Open panel front • First. don’t remove the hole. Inc. Insert drain hose in the handle of drain pan. then cover side is separated. • In case connecting direction is left or right.Installation 2.Pull the grille bottom. GU ID EM AP Copyright ©2007 LG Electronics.2~0.3") IN ST AL LA TIO N . IN ST AII AT IO N GU ID EM AP 8. Hang the hole of product at the upper screws. Drive the fore plastic anchors into drilled points. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side. Check the fixed product with light power. Remove the map) (Falling attention) INS TAL LAT ION GUID EM AP In case of nothing wrong in the matter. 5 on this page when making a hole in the wall. Look at suited horizon by horizontal meter on the horizontal setting line. Make a hole with diameter of 6mm and depth of 30-35mm when piercing a screw point. Inc. Plastic anchors Plastic anchors 4. WALL Indoor Outdoor 6.39 - LGE Internal Use Only 5-7mm Horizontality (0. Drive the lower parts after facing the hole of product with plastic anchors. First. All right reserved. (In case of piercing rear surface) Refer to No. Drill the piercing part for connecting pipe as diameter 50mm. (Installation manual reference) Hanger hole (Rear side of product) 5. and fix completely the upper screws. Put an Installation Guide Map on the desired surface. (In this time. (Leave 10mm for hanging product) mm 10 IN ST AL LA TIO N 3. INSTALLATION GUIDE MAP 7. Drive the two points of the upper parts by screws. Only for training and service purposes . and Fix lightly the map by adhesive tape. IN ST AL LA TIO N GU GU ID EM AP 9. connect the pipe and the wire.Installation I Sticking the installation guide map and fixing Indoor unit 1. I Drill a hole in the wall • Drill the piping hole with a ø50mm hole core drill. 2. Installation Plate 3). use anchor bolts.Installation 3. All right reserved. If mounting the unit on a concrete wall. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side. 12k) SZ (7k) Distance (mm) A 92 35 B 44 33 C 67 156 D 44 33 B Copyright ©2007 LG Electronics. Art Cool Deluxe Type Indoor Unit The wall you select should be strong and solid enough to prevent vibration 1) Mount the installation plate on the wall with four type A screws. (SU) C Installation plate D Ø70mm A Right rear piping Left rear piping (SZ) Installation plate D C Left rear piping B Ø70mm A Right rear piping CHASSIS (Grade) SU (9k. WALL Indoor Outdoor Type "A" screw 2) Measure the wall and mark the centerline. Drilling the hole through the wall for piping connections must be done safely. Drill a hole in the wall • Drill the piping hole with a ø70mm hole core drill. Inc. Only for training and service purposes . • Mount the installation plate horizontally by aligning the centerline using a level. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typically.40 - LGE Internal Use Only (3/16"~5/16") 5-7mm . Duct Type Indoor Unit . etc. is stored or vented. Avoid places where inflammable gas is generated. 4.BH chassis Install the unit above the ceiling correctly. Inc. washer X 4 supply) M10 Nut X4 . All right reserved. In these cases.5 450 30 87 830 186 I F (G) D C E . flows in. H Drainage hole CASE 2 POSITION OF CONSOLE BOLT • A place where the unit will be leveled and that can support the weight of the unit. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories. Avoid places where sulfurous acid gas or corrosive gas is generated. Copyright ©2007 LG Electronics. M10 Nut X4 (Local M10 SP. 5. • Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam. • A place where the unit can withstand its vibration. take the following actions: • Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily steam which should not flow into the suction of the air conditioner. 3. Avoid places near high frequency generators.41 - LGE Internal Use Only 1-3 mm 30k. In such places as restaurants and kitchens. 36k 1232 1180 355 45. resulting in heat exchange reduction.Installation 4. • Apply a filter Accessory at air return hole. 24k 932 880 355 45. the fin of the heat exchanger. etc. considerable amount of oil steam and flour adhere to the fan. washer X 4 supply) M10 washer X4 NOTE: • Throughly study the following installation locations: 1. 2. A B CASE 1 POSITION OF SUSPENSION BOLT • Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. dispersing of water drops. • A place where service can be easily performed. Only for training and service purposes M10 washer X4 (Local M10 SP.5 450 30 87 750 163 • Install the unit leaning to a drainage hole side as a figure for easy water drainage. spraying. (Unit:mm) Dimension A B C D E F (G) H I Capacity 18k. • Apply a filter Accessory at air return hole. A B CASE 1 POSITION OF SUSPENSION BOLT • Apply a joint-canvas between the unit and duct to absorb unnecessary vibration.Installation . Inc. M10 Nut X4 (Local M10 SP. Only for training and service purposes . • A place where service can be easily performed. (Unit:mm) Dimension Capacity 9/12K 18K A 708 B 678 C 434 D 51 51 E 537 535 F G H 172 175 455 230 805 230 1060 1030 434 • Install the unit leaning to a drainage hole side as a figure for easy water drainage. F Drainage hole CASE 2 POSITION OF CONSOLE BOLT • A place where the unit will be leveled and that can support the weight of the unit.BT chassis Install the unit above the ceiling correctly. • A place where the unit can withstand its vibration. All right reserved. washer X 4 supply) M10 washer X4 M10 washer X4 (Local M10 SP.42 - LGE Internal Use Only 1-3 mm G H D C E . washer X 4 supply) M10 Nut X4 Copyright ©2007 LG Electronics. (Unit:mm) Capacity Dimension A B C D E F G H I J K B 9k/12k BTU/h 633 580 695 660 750 45 369 797 20 232 372 F • Install the unit leaning to a drainage hole side as a figure for easy water drainage. washer X 4 supply) M10 washer X4 M10 washer X4 (Local M10 SP. H Drainage hole CASE 2 POSITION OF CONSOLE BOLT • A place where the unit will be leveled and that can support the weight of the unit.43 - LGE Internal Use Only 1-3 mm I D E . Inc. • A place where the unit can withstand its vibration.BP chassis Install the unit above the ceiling correctly. • Apply a filter Accessory at air return hole. Only for training and service purposes . M10 Nut X4 (Local M10 SP. All right reserved. • A place where service can be easily performed. G H CASE 1 POSITION OF SUSPENSION BOLT • Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. washer X 4 supply) M10 Nut X4 Copyright ©2007 LG Electronics.Installation C A . B2 Chassis Installation of Unit Install the unit above the ceiling correctly.5 F 190 190 G H I 1/100 9/12k BTU/h 850 900 383 18/24k BTU/h 1130 1180 383 20.6 795 163 20.6 1065 163 G H Drainage hole CASE 2 • Install the unit leaning to a drainage hole side as a figure for easy water drainage. M10 washer X4 (Local M10 SP. • A place where service can be easily performed. All right reserved.5 93.44 - LGE Internal Use Only I F E C D . Inc. washer X 4 supply) M10 Nut X4 Copyright ©2007 LG Electronics. M10 Nut X4 (Local M10 SP. washer X 4 supply) M10 washer X4 POSITION OF CONSOLE BOLT • A place where the unit will be leveled and that can support the weight of the unit. CASE 1 POSITION OF SUSPENSION BOLT • Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. • Apply a filter Accessory at air return hole.B1. Only for training and service purposes . • A place where the unit can withstand its vibration.Installation . (Unit:mm) Dimension Capacity B A A B C D 570 570 E 93. 5m longer than the length of the pipe. Some refrgerant gas may leak. • Fit the copper pipe end into the Bar of flare tool about 0~0. • Use the accessory piping kit or the pipes purchased locally. Reamer CAUTION: If burrs are not removed. onto the copper pipes. "A": ø15.88 mm (5/8") ¡ 0~1. 4) Tape the flaring portion to protect it from the dust or damages.52 mm (3/8") ¡ 0~0.45 - LGE Internal Use Only . (See illustration) • Flare the pipe ends. Preparation of pipings 1) Cut the pipes and the cable.7 mm (1/2") ¡ 0~0. Point down 3) Flaring the pipes. • Insert the flare nuts. carefully check the flare finish. Copyright ©2007 LG Electronics.35 mm (1/4") ¡ 0~0. the internal surface flare will evenly shine and be of even thickness.5 mm ø6.5 mm ø9. Only for training and service purposes .Installation Piping and Drainage of Indoor Unit 1. they may cause a gas leakage. • Turn the pipe end toward down to avoid the metal powder entering the pipe. • Measure the distance between the indoor and the outdoor unit. All right reserved.5mm higher. Inc. as some gas is charged to prevent the inside of the pipe from rusting. • Remove burrs from cut edges of pipes. Pipe cutter 90 Slanted Rough Pipe 2) Remove burrs.0 mm ø12. when the flare nuts are removed from the indoor unit. Since the flare part comes into contact with the connectors. mounted on the connection ports of both indoor and outdoor unit.5 mm Handle Yoke Cone Bar Bar Copper pipe "A" Clamp handle Red arrow mark = Improper flaring = Inclined Surface damaged Cracked Uneven thickness When properly flared. • Cut the cable 1. • Cut the pipes a little longer than the measured distance. CAUTION When install. Connecting the pipings to the indoor unit and drain hose to drain pipe. Copyright ©2007 LG Electronics. • Remove the plastic tubing retainer(see illustration below) and pull the tubing and drain hose away from chassis. Drain hose • Align the center of the pipings and sufficiently tighten the flare nut by hand. Indoor unit installation • Hook the indoor unit onto the upper portion of the installation plate. *Foamed polyethylene or equivalent is recommended. Tape the tubing. Inc. especially power cord and connecting cable. For left rear piping 1. • Do not connect the cable to the indoor unit. press the bottom of chassis near the holder upward and pull the tab out of its hole. Route the indoor tubing and the drain hose in the direction of rear left. Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole.) Ensure that the hooks are properly seated on the installation plate by moving it left and right. insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. • Make a small loop with the cable for easy connection later.Installation Connection of indoor unit piping 1. Split Type Indoor Unit • Preparing the indoor unit's piping and drain hose for installation through the wall. 2.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate. 4. Only for training and service purposes Indoor unit tubing Flare nut Pipings . 5. Be sure that the drain hose is located at the lowest side of the bundle. All right reserved. Locating at the upper side can cause drain pan to overflow inside the unit. Connecting cable Drain hose Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). drain hose and the connecting cable. 2 Pull 1 Press NOTE: If the drain hose is routed inside the room. 3.46 - LGE Internal Use Only . Loop Connecting cable Gas side piping Liquid side piping Tubing holder Drain hose To remove the holder. make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose. • Replace the plastic tubing holder in the original position. Installation • When extending the drain hose at the indoor unit, install the drain pipe. For right rear piping 1. Route the indoor tubing and the drain hose to the required piping hole position. Drain pipe Indoor unit drain hose Vinyl tape(narrow) Adhesive 6. Wrap the insulation material around the connecting portion. • Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap. Plastic bands Insulation material 2. Insert the piping, drain hose and the connecting cable into the piping hole. Connecting cable Drain pipe 3. Insert the connecting cable into the indoor unit. • Don't connect the cable to the indoor unit. • Make a small loop with the cable for easy connection later. 4. Tape the drain hose and the connecting cable. • Connecting cable Connection pipe Vinyl tape (wide) Connecting cable Indoor unit pipe Wrap with vinyl tape • Wrap the area which accommodates the rear piping housing section with vinyl tape. Pipe Vinyl tape(narrow) 5. Indoor unit installation • Bundle the piping and drain hose together by wrapping them with vinyl tape over the range within which they fit into the rear piping housing section. Wrap with vinyl tape Pipe • Hang the indoor unit from the hooks at the top of the installation plate. • Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall. Vinyl tape(wide) Drain hose Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 47 - LGE Internal Use Only Installation 6) Connecting the pipings to the indoor unit and the drain hose to drain pipe. • Align the center of the pipings and sufficiently tighten the flare nut by hand. 8) Reroute the pipings and the drain hose across the back of the chassis. Indoor unit tubing Flare nut Pipings Piping for passage through piping hole • When extending the drain hose at the indoor unit, install the drain pipe. Drain hose 9) Set the pipings and the drain hose to the back of the chassis with the tubing holder. • Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged at the bottom of chassis. Indoor unit drain hose Vinyl tape (narrow) Adhesive 7) Wrap the insulation material around the connecting portion. • Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap. Plastic bands Insulation material 1 Hook 2 Push Tubing holder • Wrap the area which accommodates the rear piping housing section with vinyl tape. Connection pipe Vinyl tape (wide) Indoor unit piping Wrap with vinyl tape 10) Indoor unit installation • Remove the spacer. • Ensure that the hooks are properly seated on the installation plate by moving it left and right. Pipe Vinyl tape (narrow) Connecting cable Drain hose Connecting cable • Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section. Pipe Drain hose Vinyl tape (narrow) Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). Wrap with vinyl tape(wide) Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 48 - LGE Internal Use Only Installation 2. Art Cool Type Indoor Unit • Preparing the indoor unit's piping and drain hose for installation through the wall. 1) Route the indoor tubing and the drain hose in the direction of rear left or right. 2) Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. • When extending the drain hose at the indoor unit, install the drain pipe. Drain pipe Indoor unit drain hose Adhesive Vinyl tape(narrow) 4) Wrap the insulation material around the connecting portion. • Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap. Plastic bands Insulation material Loop Connecting cable Drain hose Gas side piping Liquid side piping NOTE: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended. • Wrap the area which accommodates the rear piping housing section with vinyl tape. Connection pipe Vinyl tape (wide) Wrap with vinyl tape Indoor unit pipe 3) Connecting the pipings to the indoor unit and drain hose to drain pipe. • Align the center of the pipes and sufficiently tighten the flare nut by hand. Connecting cable Pipe Vinyl tape(narrow) Indoor unit tubing Flare nut Pipes • Tighten the flare nut with a wrench. Open-end wrench (fixed) • Bundle the piping and drain hose together by wrapping them with vinyl tape for enough to cover where they fit into the rear piping housing section. Wrap with vinyl tape Pipe Flare nut Wrench Indoor unit tubing Connection pipe Vinyl tape(wide) Drain hose Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 49 - LGE Internal Use Only Installation I Panel Assembly 1. First, Check the side cover assembly exactly, Fix power cord in the bottom groove of cover side left. 2. Assemble connecting lead wire with controller and first fix the upper part of panel front, then match the lower part of panel front Panel Front Connector 3. Drive two screws. Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 50 - LGE Internal Use Only Installation 3. Art Cool Deluxe Type Indoor Unit Connection of piping Indoor • Preparing the indoor unit's piping and drain hose for installation through the wall. • Remove the plastic tubing retainer(see illustration below) and pull the tubing and drain hose away from chassis. • Replace the plastic tubing holder in the original position. (Optional) NOTE: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended. 4. Indoor unit installation • Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right. Connecting cable Drain hose For right rear piping 1. Route the indoor tubing and the drain hose in the direction of rear right. Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). 4. Connecting the pipings to the indoor unit and drain hose to drain pipe. • Align the center of the pipes and sufficiently tighten the flare nut by hand. Drain hose Indoor unit tubing Flare nut Pipes • Tighten the flare nut with a wrench. 2. Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole. • Do not connect the cable to the indoor unit. • Make a small loop with the cable for easy connection later. 3. Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. Open-end wrench (fixed) Flare nut Wrench Indoor unit tubing Connection pipe Outside diameter mm Ø6.35 Ø9.52 Ø12.7 inch 1/4 3/8 1/2 Torque kg.m 1.8 4.2 5.5 • When extending the drain hose at the indoor unit, install the drain pipe. Tape Connecting pipe Drain hose Connecting cable Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 51 - LGE Internal Use Only 52 - LGE Internal Use Only . Open-end wrench (fixed) Flare nut Wrench Indoor unit tubing Connection pipe 2. Wrap the insulation material around the connecting portion. install the drain pipe.2 5.35 1/4 Ø9.7 1/2 Torque kg. Indoor unit installation • Hang the indoor unit from the hooks at the top of the installation plate. drain hose.Installation 5. Copyright ©2007 LG Electronics. Bind them together with vinyl tape so that there is no gap. All right reserved. Connecting the pipings to the indoor unit and the drain hose to drain pipe. • Tighten the flare nut with a wrench. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall. • Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Wrap with vinyl tape Pipe 6. Vinyl tape(wide) Drain hose Indoor unit tubing Flare nut Pipes For left rear piping 1. Drain hose 3. and the connecting cable into the piping hole.m 1. • Connecting cable • Wrap the area which accommodates the rear piping housing section with vinyl tape. Insert the piping. • Insert the spacer etc. Indoor unit Spacer Pipe Installation plate Vinyl tape(narrow) 8cm • Bundle the piping and drain hose together by wrapping them with vinyl tape for enough to cover where they fit into the rear piping housing section. Tape the drain hose and the connecting cable. Route the indoor tubing and the drain hose to the required piping hole position.5 Connecting cable Drain pipe • When extending the drain hose at the indoor unit. Insert the connecting cable into the indoor unit.8 4. • Make a small loop with the cable for easy connection later. Inc. • Align the center of the pipes and sufficiently tighten the flare nut by hand. Plastic bands Insulation material 4.52 3/8 Ø12. Outside diameter mm inch Ø6. • Don't connect the cable to the indoor unit. Only for training and service purposes Indoor unit drain hose Adhesive Vinyl tape (narrow) . Connection pipe Vinyl tape Wrap with vinyl tape (wide) Connecting cable Indoor unit pipe 5. Connecting cable Drain hose • Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section. Inc. Pipe Drain hose Vinyl tape(narrow) Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). • Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. All right reserved. • Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged at the bottom of chassis. Connection pipe Vinyl tape (wide) Wrap with vinyl tape Pipe Vinyl tape(narrow) Connecting cable Indoor unit piping 10. Bind them together with vinyl tape so that there is no gap. Indoor unit installation • Remove the spacer.53 - LGE Internal Use Only . Wrap the insulation material around the connecting portion.Installation 7. Reroute the pipings and the drain hose across the back of the chassis. Wrap with vinyl tape(wide) 8. Only for training and service purposes . • Ensure that the hooks are properly seated on the installation plate by moving it left and right. Plastic bands Insulation material 9. Tubing holder • Wrap the area which accommodates the rear piping housing section with vinyl tape. Set the pipings and the drain hose to the back of the chassis with the tubing holder. Piping for passage through piping hole Copyright ©2007 LG Electronics. • Bend the tubing to the left side of chassis. Follow the instruction below. • Press on the upper side of clamp. Copyright ©2007 LG Electronics. Only for training and service purposes . ( ) • Bend the tubing to the left side of chassis. All right reserved.Installation CAUTION • Bad case I Following bending type from right to left could cause problem of pipe damage. Inc.54 - LGE Internal Use Only . Installation Information (For left piping) • Good case For left piping. W3/8 or M10 . Only for training and service purposes . Inc. washers and spring washers.55 - LGE Internal Use Only . New building 1 Set anchor 2 Plate washer 3 Spring washer 4 Nut 5 Suspension bolts • Local supply ➀ Set anchor ➁ Plate washer ➂ Spring washer ➃ Nut ➄ Suspension bolt CAUTION: Tighten the nut and bolt to prevent unit falling. • Drill the hole for set anchor on the face of ceiling.W3/8 or M10 Copyright ©2007 LG Electronics. • Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts. • Mount the suspension bolts to the set anchor firmly.M10 . Old building • Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. All right reserved.Installation 4.M10 . . Duct Type Indoor Unit 1) Indoor Unit Installation • Select and mark the position for fixing bolts. • Unhook the 'Inlet hanger' from the 'Hanger screw' on the both left and right side. • Detach 'Side Plate (R. All right reserved. Indoor WALL Outdoor 5~7mm Copyright ©2007 LG Electronics. Suspension bolt Center-line for the piping hole 265 2) 1236 • Drill the piping hole on the wall slightly tilted to the outdoor side using a ø70 hole-core drill. CVT Type Indoor Unit . select the bent direction of the Installion Plate to the inside or the outside according to the installation circumstances. and it will stop at slightly tilted position. Detach them by removing each 3 screws at both sides.L)' by removing each 2 screws on both sides. • Drill the hole for anchor nut on the ceiling. Inc. • Pull the upper right and left side of 'Inlet Grille' to the front. Side Plate R Install Plate Inlet hanger R 1) Installation on the ceiling • Measure and mark the position for the Suspension bolts and the piping hole. Only for training and service purposes . prepare Installation Plates • 'Installation Plates' are attached at the bottom of indoor unit.Installation 5.56 - LGE Internal Use Only .VB chassis I Before Installing. Inlet Grille Hanger screw 1076 265 1) Before secure the Installation Plates. • Detach the 'Inlet Grille' from the Indoor Unit. back-forth by adjusting suspension bolts. Only for training and service purposes .) using nuts. • Adjust a level with a level gauge on the direction of left-right. • Secure the Installation plates onto the Suspension bolts (adjust level roughly.Installation • Insert the nuts and washer onto the suspension bolts for locking the suspension bolts on the ceiling. All right reserved. 1) Nut Anchor nut Ceiling Washer Suspension bolts Suspension bolts Spring washer Nut max. washers and spring washers. 12mm Washer 2) • Engage 2 hooks on the both left and right side of the unit to the lower slot of Installation Plates. • Move the hooks on the unit to the upper slot of Installation Plates.57 - LGE Internal Use Only . Then the unit will be declined to the bottomside so as to drain well. Inc. • Mount the suspension bolts to the anchor-nuts firmly. Lower slot Level gauge R Suspension bolt Adjust a level Installation plate R Upper slot R Copyright ©2007 LG Electronics. VE chassis The wall you select should be strong and solid enough to prevent vibration 1. If mounting the unit on a concrete wall. All right reserved. Copyright ©2007 LG Electronics. • Mount the installation plate horizontally by aligning the centerline using a level. use anchor bolts. 70 Installation plate Ø70mm Left rear piping 120 more than 200 Floor 70 Ø70mm Right rear piping Mounting the anchor Nut & Bolt (Ceiling Mounting) • Prepare 4 suspension bolts (Each bolts length should be same. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typically.58 - LGE Internal Use Only . • Insert the nuts and washer onto the suspension bolts for locking the suspension bolts on the ceiling. Drilling the hole through the wall for piping connections must be done safely.) • Measure and mark the position for the Suspension bolts and the piping hole. Inc. Type "A" screw Installation Plate 2. Mount the installation plate on the wall with type "A" screws. Only for training and service purposes . Measure the wall and mark the centerline. • Mount the suspension bolts to the anchor-nuts firmly.Installation . ) using nuts. 12mm Nut Washer Drill a Hole in the Wall • Drill the piping hole with a ø70mm hole core drill. Only for training and service purposes . washers and spring washers. WALL Indoor Outdoor Copyright ©2007 LG Electronics.59 - LGE Internal Use Only (3/16"~5/16") 5-7mm . Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side. • Move the hooks on the unit to the upper slot of Installation Plates. • Adjust a level with a level gauge on the direction of left-right. All right reserved. Anchor nut Ceiling Nut Suspension bolts Washer 235 820 Suspension bolt Center-line for the piping hole Suspension bolts Spring washer Hangen Max. Inc. • Engage 2 hooks on the both left and right side of the unit to the lower slot of Installation Plates. Then the unit will be declined to the bottomside so as to drain well.Installation • Secure the Installation plates onto the Suspension bolts (adjust level roughly. back-forth by adjusting suspension bolts. 2. Inc.60 - LGE Internal Use Only .Installation CAUTION: Installation Information For Declination CAUTION 1. 3. Install declination of the indoor unit is very important for the drain of the convertible type air conditioner. Minimum thickness of the insulation for the connecting pipe shall be 7mm. If the Installation Plates are fixed to horizontal line. Ceiling Drain hose Ceiling Side of view • The unit must be declined to the bottomside of the unit when finished installation. Only for training and service purposes . Ceiling Copyright ©2007 LG Electronics. the indoor unit after installing will be declined to the bottomside. All right reserved. Front of view • The unit must be horizontal or declined to the drain hose connected when finished installation. 61 - LGE Internal Use Only . • Fasten the screws. Only for training and service purposes . refer to "Connecting pipe and cable to Indoor Unit". R • Before working.Installation • Secure the unit to the Installation Plates with four M8 bolts and washers. • Hang the Inlet Hanger to the screw. 2 R 1 R Copyright ©2007 LG Electronics. • Hook up the Inlet Grille Hook to the cabinet. Inc. All right reserved. Inlet hanger R Hook Cabinet Bottom • Fit the projection hooks of the side plates to the 'Side Panel' and the 'Front Panel' by lifting it. select the bent direction of the 'Install Plate' to the inside or outside according to the installation circumstances. Wall Indoor Outdoor • Secure the 'Install Plate' onto the wall with four anchor bolts. Inc. Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose.62 - LGE Internal Use Only 5~7mm . Spring washer Wall Nut Washer Anchor nut Less than 12mm Before secure the Install Plates. Only for training and service purposes . 123 6 Copyright ©2007 LG Electronics. washers and spring washers. All right reserved. 1076 mor e th 260 an 265 • Drill the piping hole on the wall slightly tilted to the outdoor side using a ø70 hole-core drill.Installation 2) Installation on the Wall • Select and mark the position for fixing bolts and piping hole. • Drill the hole for anchor nut on the wall. • Secure the unit to the Installation Plate with four M8 bolts and washers. All right reserved. Inner slot R • Before working. • Hook up the Inlet Grille Hook to the cabinet. • Hang the Inlet Hanger to the screw. Copyright ©2007 LG Electronics. • Fasten the screws. 2 1 • Fit the projection hooks of the side plates to the 'Side Panel' and the 'Front Panel' by lifting it.63 - LGE Internal Use Only . Only for training and service purposes . • Insert 2 hooks on the both left and right side of the unit to the inner slot (wall side) of the Installation Plate.Installation Install the Indoor unit onto Installation Plate. refer to "Connecting pipe and cable to Indoor Unit". Inc. Only for training and service purposes . • Assemble the 'Side Plates(R.L)' with 2 screws on both left and right side. • Secure the Mount Brackets on the wall with four M4 screws. From the left wall more than 760mm From the right wall more than 840mm Slot Floor mount bracket 448mm • Drill the piping hole with 70mm dia.Installation 3) Installation on the floor Installation of Mount Bracket. Wall Indoor Outdoor After Installing. reassemble detached parts. Slot Wall Floor mount bracket Install plate Piping hole Copyright ©2007 LG Electronics. • Drill the hole for the anchor nut on the wall. • Piping hole should be slightly slant to the outdoor side.64 - LGE Internal Use Only 5~7mm . • Hang the 'Inlet Grille' and hook the 'Inlet Hanger' to the Hanger Screw. • Drill the piping hole using a ø70 hole-core drill. hole core drill. Install the indoor unit onto the Mount Brackets. • Select and mark the position for Mount Brackets and the piping hole. • Engage the slot at the back of the unit with Mount Bracket. Inc. All right reserved. • Drill the hole for anchor bolt on the wall.4 (Hanging bolt) 860 430 (Ceiling opening) 390 328. Cooking table 2. • Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam. • Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose. All right reserved. These may cause heat exchange efficiency reduction. Avoid places near high frequency generators. Copyright ©2007 LG Electronics.65 - LGE Internal Use Only . 1. Ceiling board NOTE: • Avoid the following installation location. • During the installation. • Install the unit horizontally using a level gauge. or water drops.6 893.000 (Ceiling opening) 931.4 (Hanging bolt) 30. TC1 chassis 1) Ceiling opening dimensions and hanging bolt location • The dimensions of the paper model for installing are the same as those of the ceiling opening dimensions. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.TC. Ceiling Cassette Type Indoor Unit . care should be taken not to damage electric wires. Air conditioner Take enough distance Use the ventilation fan for smoke-collecting hood with sufficient capacity. Avoid places where inflammable gas is generated. 1.Installation 6. Avoid installng air conditioner in such places where cooking oil or iron powder is generated. drain pump mal-function. Inc. • Select and mark the position for fixing bolts and piping hole. take the following actions. • Make sure that ventilation fan is enough to cover all noxious gases from this place. In these cases.8 Ceiling Level gauge CAUTION • This air-conditioner uses a drain pump. Only for training and service purposes . Avoid place where noxious gas is generated. 3. 5. 4. W 3/8 or M10 Nut . Inc. Hanging Bolt .66 - LGE Internal Use Only 5~7mm 103mm .M10 Plate Washer . Copyright ©2007 LG Electronics. Only for training and service purposes . Wall Indoor Outdoor CAUTION • Tighten the nut and bolt to prevent unit from falling off. All right reserved.Installation 2) Indoor Unit Installation Ceiling Hanging bolt (W3/8 or M10) Nut (W3/8 or M10) Spring washer (M10) Keep the length of the bolt from the bracket to 40mm Flat washer for M10 (accessory) Ceiling board Air Conditioner body Ceiling board Flat washer for M10 (accessory) Nut (W3/8 or M10) Paper model for installation Set screw of paper model (4 pieces) Open the ceiling board along the outer edge of the paper model Adjust the same height • The following parts are local purchasing.M10 • Drill the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 hole-core drill.W 3/8 or M10 Spring Washer . Ceiling Cassette Type Indoor Unit .5 66 Unit:mm TH/TD 840 Unit size 840 Unit size Unit:mm Copyright ©2007 LG Electronics.Installation 7.67 - LGE Internal Use Only 875 (Ceiling opening) 790 (Ceiling opening) 658 (Hanging bolt) 600 (Ceiling opening) TF . All right reserved.5 75 570 Unit size Level gauge 570 Unit size CAUTION • This air-conditioner uses a drain pump. 600 (Ceiling opening) 39. be careful not to damage electric wires. 790 (Ceiling opening) 109 572(Hanging bolt) 75 109 450 (Hanging bolt) Ceiling Unit:mm 66 744 Unit size • Select and mark the position for fixing bolts and piping hole.5 521(Hanging bolt) TE(1) 39. • Drill the hole for anchor bolt on the wall. • During the installation.5 672 (Hanging bolt) 101. • Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose.TE(1)/TF/TH/TD chassis 1) Ceiling opening dimensions and hanging bolt location • The dimensions of cardboard for installing are the same as those of the ceiling opening dimensions. • Install the unit horizontally using a level gauge. Inc. 744 Unit size Ceiling board 875 (Ceiling opening) 45 785 (Hanging bolt) 45 101. Only for training and service purposes . Air conditioner Take enough distance Use the ventilation fan for smoke-collecting hood with sufficient capacity.M10 • Drill the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 hole-core drill.W 3/8 or M10 Spring Washer . Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated. Avoid places near high frequency generators.Installation NOTE: • Avoid the following installation location. In these cases. 2) The Indoor Unit Installation Ceiling Hanging bolt (W3/8 or M10) Nut (W3/8 or M10) Spring washer (M10) Keep the length of the bolt from the bracket to 40mm Flat washer for M10 (accessory) Ceiling board Air Conditioner body Ceiling board Flat washer for M10 (accessory) Nut (W3/8 or M10) Cardboard for installation Set screw of cardboard (4 pieces) Open the ceiling board along the outer edge of the paper model Adjust the same height • The following parts are local purchasing. Avoid installng air conditioner in such places where cooking oil or iron powder is generated. Avoid place where noxious gas is generated.W 3/8 or M10 Nut . 3. 4. 1.68 - LGE Internal Use Only 5~7mm • Tighten the nut and bolt to prevent the unit from falling off. or water drops. 150mm . take the following actions. • Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam. Hanging Bolt . Inc. • Make sure that ventilation fan is enough to cover all noxious gases from this place. drain pump mal-function. Wall Indoor Outdoor CAUTION Copyright ©2007 LG Electronics. Cooking table 2.M10 Plate Washer . 5. Avoid places where inflammable gas is generated. Only for training and service purposes . All right reserved. These may cause heat exchange efficiency reduction. All right reserved. place the cord at least 5cm away from other power cables (audio equipment. display is difficult to see. provide a trap at the top of the cord to prevent water droplets from running. • To protect the remote controller cord from electrical noise. • This remote controller equipped with liquid crystal display. el ow er pa rt Lever carefully the box open using a screw driver. The maximum length of the cord is 100m. • The room temperature sensor is built in the indoor unit. Installation of the remote controller • Select places that are not splashed with water.(The standard height is 1.5mm .2 ~ 1. Only for training and service purposes .Installation Remote Controller Installation • Although the room temperature sensor is in the indoor unit. etc. • Select control position after receiving customer approval. television set.5m high) Routing of the remote controller cord • Keep the remote controller cord away from the refrigerant piping and the drain piping. Remote control box body • Fix the under plate on the wall Face of wall Under plate • Fix the cord clamps on the wall by ø 3 tapping screws (accessory). If the length of the cord exceeds 50m. WIRED REMOTE CONTROL INSTALLATION DISASSEMBLING Front case Th • Separate the under plate from Remote control box. the remote controller should be installed in such places away from direct sunlight and high humidity. 2 use a wire size greater than 0. If this position is higher or lower. Inc. Copyright ©2007 LG Electronics.) • If the remote controller cord is secured to the wall. • Fix the remote control cord. etc.69 - LGE Internal Use Only . Cord clamp (accessory) Screw (accessory) ELECTRICAL WIRING (Main board) CN REMO Remote controller Wire and make sure that teminal numbers are matched on unit side and remote controller side. All right reserved. • Slide the cover according to the arrow direction.70 - LGE Internal Use Only . Only for training and service purposes . • Romove the batteries from the remote controller if the air conditioner is not going to be used for some long time. • Be sure that both batteries are new. such batteries differ from standard dry cells in shape. Insert the two batteries. Copyright ©2007 LG Electronics. dimensions. • Slide it back into position. Re-attach the cover.Installation REMOTE CONTROL PREPARATION(OPTIONAL) HOW TO MOUNT ONTO A WALL HOW TO INSERT BATTERIES Remove the battery cover from the remote controller. Inc. and performance. • Be sure that the (+) and (-) directions are correct. • Do not use rechargeable batteries. 2) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors. (If they are loose.71 - LGE Internal Use Only . (Particularly note the relation between cable length and thickness.) 8) Never fail to equip a leakage breaker where it is wet or moist. Outdoor unit A-UNIT Gas side piping B-UNIT Liquid side piping A *Connecting pipe size Indoor Units 7K/9K/12K 18K/24K 30K/36K Gas side Ø9. As for the method of wiring.52 ¡Ø15. • Vibration of a magnetic switch. 2) Socket is fitted in BD unit (Socket P/No. damage on the contact point there of.7(1/2) Ø15. All right reserved. be guided by the circuit diagram pasted on the inside of control box cover. it could give rise to burn-out of the wires. fuse breaking.35(1/4) Ø6. disturbance to the normal function of a overload protection device. Check them and make sure that they are all tightly fastened. 9) The following troubles would be caused by voltage drop-down.52(3/8) Ø12.52¡Ø12. 5) Confirm that electrical capacity is sufficient.: 5001A30059A) Connector CAUTION: After the confirmation of the above conditions.7 Ø9. • Proper starting power is not given to the compressor. tighten the flare nut with torque wrench until the wrench clicks.) 4) Specification of power source. 6) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.35(1/4) 2) Align the center of the pipings and sufficiently tighten the flare nut by hand 4) Distributor type piping (only A4UW306FA1) 1) Connect main piping from outdooor to BD unit using socket.35(1/4) Ø6. ensure the direction for tightening follows the arrow on the wrench. Connecting the pipings to the Outdoor unit 1) When piping installation work you must be used the connector. Copyright ©2007 LG Electronics. 3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Only for training and service purposes .88(5/8) B Torque wrench Liquid side Ø6. I When tightening the flare nut with torque wrench. prepare the wiring as follows: 1) Never fail to have an individual power specialized for the air conditioner.Installation Connecting Pipings and the cable to Outdoor unit 1.88 Liquid Not available Not available 3) Finally. Inc. 7) Confirm that the cable thickness is as specified in the power sources specification. Indoor Units 18K/24K 30K/36K Gas A¡B Ø9. 25 x 5.041*2 0.041 0. comp.00 14.05 8 6 0. MSC & RLA are measured as the compressor only test condition.73 0.0 6.Installation 2.0 0.25 x 5.1/7.25 x Load1) + Load2 + Load3 = (1.) / (const.30 27.55 17. All right reserved.0/8.0/8.45 39. Inc.50 13.Load2 : sum of current for all other motors .8) + 0 + 0 = 7.067 0.8 56.25 13. Voltage range Voltage supplied to the unit terminals should be within the minimum and maximum range 2.73 0.067 0. comp. Select proper circuit breaker as given below MCA < Circuit breaker MOP 6.72 - LGE Internal Use Only .041 0.0 9.25 x Load1) + Load2 + Load3 MOP = (2.7 17.68 0. Recommended circuit breaker is ELCB (Earth Leakage circuit breaker) 7.) 10.0 : MSC of (inv.12x2 0.0/14.0A or more 4.75 9.75 13. MCA / MOP MCA = (1. comp.0/8.6 29.Load3 : any other load rated 1.) MPS inverter MPS Inverter 50 220~240 MIN. sheet) 2 MCA = (1.25 x Load1) + Load2 + Load3 .1/14.43 23. Maximum allowable voltage unbalance between phase is 2 % 3.40 8 6 0.0 : RLA of (inv. 8.:264 Inverter 8.0 8.3 32.50 15.) / (const.8) + 0 + 0 = 13.0 14/35/63 7. Electric characteristics Unit Model A2UW146FA0 [FM14AH UE0] A2UW146FA1 [FM15AH UE1] A2UW146FA2 [FM15AH UL2] A2UW166FA0 [FM17AH UL0] A2UW166FA1 [FM17AH UL1] A2UW186FA0 [FM18AH UE0] A3UW186FA0 [FM19AH UE0] A3UW246FA0 [FM24AH UE0] A4UW246FA0 [FM25AH UE0] A4UW306FA0 [FM30AH UE0] A6UW406FA0 [FM40AH UH0] A7UW486FA0 [FM48AH UY0] A8UW566FA0 [FM56AH UY0] Notes : 1.067 0.43 2.43 0. OFM is measured as the outdoor unit test condition (Example) Selection of proper circuit breaker 1 Model : A2UW146FA0 [FM14AH UE0] .1/7.1/7.:198 MAX. Select wire spec. comp.0 14/63 7.0 26.43 14/35/35 7.0/14.1/14.0 23.Load1 : Rated running current of largest motor (compressor or other motor) .25 22.68 Type Hz Voltage Voltage range Power MCA MOP Compressor MSC RLA OFM KW FLA 7. based on the MCA 5. Ex) 6.05 A Finally select circuit breaker 15A MCA : Minimum Circuit Amperes (A) MOP : Maximum rating over current protective device MSC : Maximum Starting Current RLA : Rated Load Amperes (A) OFM : Outdoor Fan Motor kW : Fan Motor rated output (kW) FLA : Full Load Amperes (A) Copyright ©2007 LG Electronics.Rated running current : 5.25 x Load1) + Load2 + Load3 = (2.0/14.25 A 3 MOP = (2.067 0. Only for training and service purposes .73*2 0.68 0.9 14 14 7 7 0.30 24.1/7.5 50.55 24.1/14.73x2 2. MSC values 23.8 A (refer to spec.68 9.0 6. RLA is measured during each individual compressor test condition. 5mm2 mm GN /YL 20 NORMAL CROSSSECTIONAL AREA 0. CAUTION The power cord connected to the outdoor unit should be complied with the following specifications (Rubber insulation. Inc.Installation CAUTION: If a power plug is not to be used. provide a circuit breaker between power source and the unit as shown below. All right reserved. type H07RN-F approved by HAR or SAA).5mm The connecting cable connected to the indoor and outdoor unit should be complied with the following specifications (Rubber insulation. Main power source Air Conditioner Circuit Breaker Use a 30A circuit breaker or time delay fuse. ø8.73 - LGE Internal Use Only . type H05RN-F approved by HAR or SAA). Only for training and service purposes .5mm GN /YL 20 NORMAL CROSSSECTIONAL AREA 3. ø7.75mm2 mm Copyright ©2007 LG Electronics. • Remove the securing screws. Art Cool Type Indoor Unit • Pour a glass of water on the evaporator. Screw Pull the right and the left side. • Ensure if water flows drain hose of indoor unit without any leakage. pull lower the left and right side of the grille toward you (slightly tilted) and lift it straight upward. • Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. • To remove the Grille. Inc. Only for training and service purposes .Installation Checking the Drainage and Pipe forming 1. 2) Check the drainage • Pour a glass of water on the evaporator. Split Type Indoor Unit 1) Remove the Grille from the cabinet • Set the up-and-down air direction louver to open position(horizontally) by finger pressure. All right reserved. Copyright ©2007 LG Electronics.74 - LGE Internal Use Only . 2. Installation 3. Downward slope • Do not make drain piping. • Pour a glass of water on the evaporator. • Set the air direction louvers up-and-down to the position(horizontally) by hand. Art Cool Deluxe Type Indoor Unit 1) To remove the front panel from the indoor unit.75 - LGE Internal Use Only . Pull the lower left and right sides of the grille toward you and lift it off. Air filter Do not raise Inlet Grille Water leakage 2) To check the drainage. Only for training and service purposes . All right reserved. • Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. Inc. 3) Drain piping • The drain hose should point downward for easy drain flow. Connecting area drain hose Accumulated drain water Air Water leakage Waving Tip of drain hose dipped in water Water leakage Leakage checking Ditch Less than 50mm gap Copyright ©2007 LG Electronics. • Remove the securing screws that retain the front panel. Installation 4. Convertible Type Indoor Unit To remove the front panel from the indoor unit. 1. Set the air direction louvers up-and-down to the position(horizontally) by hand. 2. Remove the securing screws that retain the front panel. Pull the lower left and right sides of the grille toward you and lift it off. Pull the right and the left side. To check the drainage. 1. Pour a glass of water on the evaporator. 2. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. Drain piping 1. The drain hose should point downward for easy drain flow. Downward slope 2. Do not make drain piping like the following. Do not raise Accumulated drain water Air Tip of drain hose dipped in water Water leakage Less than 50mm gap Water leakage Water leakage Waving Ditch Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 76 - LGE Internal Use Only Installation 5. Duct Type Indoor Unit 1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe shall be 5mm. Front of view • The unit must be horizontal or declined to the drain hose connected when finished installation. Ceiling 1~3mm CORRECT Drainage hole INCORRECT Drainage hole CAUTION FOR GRADIENT OF UNIT AND DRAIN PIPING • Always lay the drain with downward inclination (1/50 to 1/100). Prevent any upward flow or reverse flow in any part. • 5mm or thicker formed thermal insulator shall always be provided for the drain pipe. Lay the drain hose with a downware inclination so water will drain out. Thermal insulator (Local supply) Drainage pipe (Local supply) Unit Make sure to be closed. Drainage hole • Upward routing not allowed 700mm (Drain pump model only) INCORRECT Applied U-Trap Dimension A ≥ 70mm B ≥ 2C C ≥ 2 x SP SP = External Pressure (mmAq) Ex) External Pressure = 10mmAq A ≥ 70mm B ≥ 40mm C ≥ 20mm CORRECT B C U-Trap A • Install the P-Trap (or U-Trap) to prevent a water leakage caused by the blocking of intake air filter. Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 77 - LGE Internal Use Only Installation 6. CST Type Indoor Unit • Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reversal flow. • During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit. • The outside diameter of the drain connection on the indoor unit is 32mm. Piping material: Polyvinyl chloride pipe VP-25 and pipe fittings • Be sure to install heat insulation on the drain piping. Heat insulation material: Polyethylene foam with thickness more than 8 mm. Pipe clamp Indoor unit Upward routing not allowed Maintenance drain port 1/50~1/100 MAX 700mm Drain test The air conditioner uses a drain pump to drain water. Use the following procedure to test the drain pump operation: Feed water Flexible drain hose (accessory) Main drain pipe Drain port Drain Pump Glue the joint Drain hose connection Use the clip (accessory) • Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end. • Feed water to the flexible drain hose and check the piping for leakage. • Be sure to check the drain pump for normal operating and noise when electrical wiring is finished. • When the test is completed, connect the flexible drain hose to the drain port on the indoor unit. Drain pan Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 78 - LGE Internal Use Only Installation Maximum Length of Pipe and Extra Charge of Refrigerant Charge 1. TPS Inverter Multi -Multi Piping Type 1.1 The maximun allowable level and piping length [Outdoor Unit] It does not matter which unit is higher. [Indoor Unit] A B 15m C 7.5m D Model [Outdoor Unit] A2UW146FA0/1/2 A2UW166FA0/1 A2UW186FA0 A3UW186FA0/1 A3UW246FA0 A4UW246FA0 A4UW24GFA0 A4UW30GFA0 A4UW306FA0 Standard Length A,B,C,D 7.5m 7.5m 7.5m A Max piping length each indoor unit B 20m 25m 25m C 25m D - Max total piping length 30m(A+B) 40m(A+B) 50m(A+B+C) 20m 25m 25m 7.5m 25m 25m 25m 25m 70m(A+B+C+D) 1.2 Refrigerant Charge Indoor Unit Capacity (Btu/h) Pipe Size Gas Liquid Rated Length Max Length Additional Refrigerant 7k, 9k, 12k 18k, 24k 3/8"(9.52mm) 1/2"(12.7mm) 1/4"(6.35mm) 1/4"(6.35mm) 7.5m 7.5m 25m 25m 25g/m 35g/m ❈ Extra refrigerant = (Extended length - Rated length) x Additional refrigerant Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 79 - LGE Internal Use Only Installation 2. TPS Inverter Multi - Distributor Type 2.1 The maximum allowable level and piping length Outdoor Unit Installation of the outdoor unit in an upper position A BD Unit L1 L2 R Place the BD unit and indoor units within a level distance of 10m from each other. L3 30m B BD Unit L4 L5 10m Main piping Branch piping L6 • Total main piping length : 50m( A + B ) • Total branch piping length : 50m(L1+L2+ L3+L4 +L5+L6) • Each branch piping length : 15m(L1,L2,L3,L4 ,L5,L6) • Total system piping length : 100m(40+60) R BD Unit Place the BD unit and indoor units within a level distance of 10m from each other. 10m BD Unit Outdoor Unit 30m Installation of the outdoor unit in a lower position Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 80 - LGE Internal Use Only Installation I Distributor Type(A4UW306FA1) Outdoor Unit Place the BD unit and indoor units within a level distance of 7. Only for training and service purposes .81 - LGE Internal Use Only . Inc.L3.L4 ) • Total system piping length : 65m(15+50) Place the BD unit and indoor units within a level distance of 7. A Installation of the outdoor unit in an upper position L1 BD Unit 15m L2 L3 7.5m Outdoor Unit 15m Installation of the outdoor unit in a lower position Copyright ©2007 LG Electronics.L2. All right reserved. R BD Unit 7.5m Main piping Branch piping L4 • Total main piping length : 15m( A ) • Total branch piping length : 50m(L1+L2+ L3+L4 ) • Each branch piping length : 15m(L1.5m from each other.5m from each other. 3 ( kg / m3 ) .rated length x 40g/m x 20g/m x 30g/m A B – Total number of connected indoor unit ✽ Note : If total additional charge value after calculation comes out to be negative.9.82 - LGE Internal Use Only .rated length 30.rated length 18. • Total main pipe(A+B+C) = 30m • Each branch pipe a = 10m b = 8m c = 5m d = 3m e = 10m • CF = 6-5 = 1 b 9k c 9k ex) A6UW406FA0 A A C a 7k B d 9k e 18k Caution ❖ Additional Charge = (30-5) x 50 + (10-5) x 20 + (8-5) x 20 + (5-5) x 20 + (3-5) x 20 + (10-5) x 30 .12 k Branch pipe length .rated length 7.2 Refrigerant charge The calculation of the additional charge should be taken in account for the length of pipe.rated length CF(Correction Factor) x 100 • Rated length = 5m.rated length 7.3 Refrigerant charge The calculation of the additional charge should be taken in account for the length of pipe. Only for training and service purposes 0. then do not consider additional charge. 2. A6UW406FA0 charge = 4100g A7UW486FA0 charge = 7100g A8UW566FA0 charge = 7100g Additional charge (g) = + + + Total Main pipe length .24 k Branch pipe length . number of connectable indoor unit Total Amount (g) = A + B x 50g/m x 20g/m x 30g/m x 35g/m A4UW306FA1 charge = 2500g Additional charge (g) = + + Total Main pipe length .(1 x 100) = 1250+100+60+0-40+150-100 = 1420 g Regulation for refrigerant leakage(in Europe) : the amount of refrigerant leakage should satisfy the following equation for human safety.12 k Branch pipe length . Inc.Installation 2.24 k Branch pipe length .9. Total amount of refrigerant in the system Volume of the room at which indoor unit of the least capacity is installed Copyright ©2007 LG Electronics.36 k Branch pipe length . • CF = Max. All right reserved.rated length 18. .35 Ø15. Reduction of the amount of refrigerant 4.4 Piping connection size A Liquid Gas mm mm Ø 9.Change indoor unit type : installation position should be over 2m from the floor (Wall mounted type ¡ Cassette type) . All right reserved.Installation ❐ If the above equation can not be satisfied. then follow the following steps. 2 or more security device installation of alarm for gas leakage .Selection of air conditioning system: select one of the next 1. Only for training and service purposes .Adoption of ventilation system : choose ordinary ventilation system or building ventilation system .52 Ø19.Limitation in piping work : design for earthquake-proof and prevention against thermal stress 2. Inc.88 B Adjust to indoor unit piping size A B B B A4UW306FA1 Copyright ©2007 LG Electronics. Effective opening part Installation 2.83 - LGE Internal Use Only . Reconfirmation of outdoor unit capacity and piping length 3.05 B Adjust to indoor unit piping size BD Unit A A A A6UW406FA0 B B B B B B Y-Branch A Liquid Gas mm mm Ø 6. 05 [unit:mm] Liquid Pipe Ø9.05 Ø19.10° A Viewed from point A in direction of arrow • There is no limitation on the joint mounting configuration.5 Necessity of a trap Since there is fear of the oil held inside the riser piping flowing back into the compressor when stopped and causing liquid compression phenomenon. Inc. CAUTIONS • Capacity is based on standard length and maximum allowance length is on the basis of reliability.52 Ø9. Only for training and service purposes . • Oil trap should be installed every 5~7 meters. the connecting section should be cut with a pipe cutter.52 Ø9.6 Y-Branch(Standard accessory) Gas Pipe Ø19. In case more then 5m 2. All right reserved.52 Y branch A To Outdoor Unit A B B To BD Unit • Ensure that the branch pipes are attached horizontally or vertically (see the diagram below. • Branch pipe should be insulated with the insulator in each kit. or cases of deterioration of oil return. Tape (field supply) Insulator (included with kit) Liquid and gas pipe joints Insulator for field piping Copyright ©2007 LG Electronics.Installation 2.05 Ø19.) Horizontal plane Facing upwards Within +/. • If the diameter of the refrigerant piping selected by the procedures described is different from the size of the joint. it will be necessary to provide a trap at an appropriate place in the riser gas piping.84 - LGE Internal Use Only . Inc.Installation Test Running SPLIT. secure the unit with an anti-vibration rubber. All right reserved. Check that the gas and liquid side service valves are fully open. Then attention must be paid.5volt) batteries. (Cassette Type) The test run is started by pressing timer cancel button five times continuously. Otherwise. Measure the temperature of the intake and discharge of air. I In the case when the vibration of the unit is conveyed to the hose. 1) Prepare remote controller Remove the battery cover by pulling it according to the arrow direction. the air conditioner should not be operated. 2) Precautions in test run I The initial power supply must provide at least 90% of the rated voltage. Do not use rechargeable batteries. 3) Settlement of outdoor unit I Anchor the outdoor unit with a bolt and nut(ø10mm) tightly and horizontally on a concrete or rigid mount. press any button. Only for training and service purposes . Insert new batteries making sure that the (+) and (–) of battery are installed correctly.85 - LGE Internal Use Only . (Test run will be cancelled 18 minutes later automatically) I The forced operation is started by pressing button for 2 seconds. it leads to the trouble of compressor. carry out the cooling operation firstly even during heating season. I When installing on the wall. Reattach the cover by pushing it back into position. Check that all tubing and wiring have been properly connected. NOTE: • Use 2 AAA(1. I For test run. Measure the pressure of the gas side service valve. anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake. 2. 3. then check the system refrigerant charge: 1. If heating operation is carried out firstly. I Carry out the test run more than 5 minutes without fail. • Remove the batteries from the remote controller if the system is not going to be used for a long time. 2. Ensure the difference between the intake temperature and the discharge is more than 8°C (Cooling) or reversely (Heating). (Cassette Type) The test run is started by pressing button for 5 seconds. ART cool deluxe Type 1. Intake temperature Discharge air Discharge temperature Intake temperature Discharge air Discharge temperature Intake temperature Discharge air Discharge temperature Copyright ©2007 LG Electronics. roof or rooftop. ART cool. Bolt Tubing connection 4) Evaluation of the performance Operate unit for 15~20 minutes. (Room type) I To cancel the test run. please change the slide switch which is on the Main PCB Assembly to the ' CEILING' state. Connect the power supply cord to the independent power supply. CN_INSTALL CEILING BOTTOM Copyright ©2007 LG Electronics. (Two "R03" or "AAA" dry-cell batteries or equivalent. In case the indoor unit is installed under the ceiling. Thermometer R 3) Selection of the slide switch according to installation method 1. Insert the two batteries. 2. Inc. Operate the unit for fifteen minutes or more. Ensure the difference between the intake temperature and the discharge one is more than 8°C (Cooling) or reversely (Heating). 3. 2. • Slide it back into position. Prepare the remote control. Remove the battery cover from the remote controller. • Insert two batteries provided.) • Be sure that the (+) and (-) directions are correct. • Circuit breaker is required. please change the side switch which is on the Main PCB Assembly to the 'BOTTOM' state. Measure the temperature of the intake and discharge air.Installation CVT Type 1) Connection of power supply 1. Re-attach the cover. The initial state of the slide switch is set for the bottom installation. • Slide the cover according to the arrow direction. In case the indoor unit is installed on the floor. Only for training and service purposes . 2) Evaluation of the performance 1.86 - LGE Internal Use Only . 2. All right reserved. • Be sure that both batteries are new. ..cm{12kgf.. Otherwise. piping temperature. For test run. All right reserved. CHECK THE FOLLOWING ITEMS WHEN INSTALLATION IS COMPLETE • After completing work.588N.. If heating operation is Caution carried out first. check following items... the air conditioner should not be operated.245N.cm} Copyright ©2007 LG Electronics... current... presence of abnormal vibration and noise. operating pressure. air velocity.cm{60kgf. outside temperature.. ❏ Is the circulation of air adequate? ❏ Is the drainage OK? ❏ Is the heat insulation complete (refrigerant and drain piping)? ❏ Is there any leakage of refrigerant? ❏ Does the romote controller works properly? ❏ Is there any error on wiring? ❏ Aren't terminal screws loosened? M4..cm} M6. press any button. be sure to measure and record trial run properties.118N.. • As to the structure and appearance. air volume. carry out the cooling operation first even during winter season. Inc. suction temperature. (Test run will be cancelled 18 minutes later automatically) • The test run is started by pressing the room temperature checking button and down timer button for 3 seconds at the same time... blow out temperature. etc..196N. Only for training and service purposes .cm} M5....Installation Ceiling Cassette Type 1) PRECAUTIONS IN TEST RUN • The initial power supply must provide at least 90% of the rated voltage. voltage. • To cancel the test run.cm{25kgf.. • Measuring data are room temperature. it leads to the trouble of compressor.cm{20kgf. Carry out the test run more than 5 minutes without stopping. and store measured data.cm} M8.87 - LGE Internal Use Only . 35) (C: Ø15.35) For 4 rooms : PMBD3640 (Ø9. Ø6.52. Ø6.88 - LGE Internal Use Only . Branch Distributor PRECAUTIONS FOR SELECTING THE LOCATION The BD unit is for indoor use. Follow the instructions in the installation manual for each unit.52. Ø6. and is in a location with little or no vibration. • Do not install near bedrooms. • When installing. • That there is nothing nearby that produces heat or steam(gas). Inc. • Do not install in location that is hot or humid for long periods of time. Only for training and service purposes . that there is enough carity for servicing the unit. Ø6.Can not be purchased separately Main Pipe B 30K(4rooms) 40K(6rooms) 48K~56K(7~8rooms) Copyright ©2007 LG Electronics.Included in outdoor unit . Ø6. • That the refrigerant pipes for the indoor and outdoor units can be repaired with ease. System Layout Distributor Unit For 2 rooms : PMBD3620 (Ø9.Installation 5.52. refer to "INSTALLATION".3rooms or 4rooms) according to the installation pattern Branch Distributor A Branch Pipe L1 L2 L3 L4 h2 Branch Distributor L5 h1 L6 L7 L8 • Y Branch Pipe .35) (B: Ø15. System Layout and Piping Length For installation of the indoor units.88. For restrictions on installation.7. • A well-ventilated area.88. All right reserved.35) For 3 rooms : PMBD3630 (Ø9. Install in a location such as above a ceiling or behind a wall in accordance with the following conditions: • That the unit is fully supported.35) Do not connect more than 8 indoor units together choose the distributor unit type (2rooms. The sound of refrigerant flowing through the piping may sometimes be audible. Ø6.35) For 3 rooms : PMBD7230 (A: Ø12. and that the units are placed well within the distance from each other allowed by the pipe length. Installation Piping length and elevation No.5 50 50 15 100 30 10 50 60 15 110 30 10 50 60 15 120 30 10 Installation • This unit may be installed suspended from the ceiling or mounted on the wall. each branch piping length Total system piping length Maxium Level in . (Servicing space) Ø19. • This unit may only be installed horizontally . • Service direction is the side B and C • The piping for the indoor unit may be led around in direction A • The inclination of side B must be within ±5 degree forward or backward or to the sides. as shown in the diagram below. (Side B is facing up) However.suspended installation and wall-mounted installation. L7. • BD unit does not require drain treatment as it uses internal insulation. L2. Only for training and service purposes . L3.in A+B L1+L2+L3+L4+L5+L6+(L7)+(L8) L1. forward or backward. L4.05 Min 30 (337) Min 400 Min 400 250 A (298) Ø9. and to the sides. 432 (36) 50 50 50 (150) (111) Main Pipe 30 50 (LEV service) B (38) 50 72 (56) 50 50 50 Branch Pipe 300 60 Cover Control C (Controller service) 250 or more Inspection opening 600 (Bottom view) Copyright ©2007 LG Electronics. it may be freely installed in any direction.89 - LGE Internal Use Only 600 . Length 4 room 6 room 7 room (m) 8 room (1) (2) (3) (4) (5) (6) Total main piping length Total branch piping length Max.out Maxium Level in . L5. Inc.L8 (Total main) + (Tatal branch) h1 h2 15 50 15 65 15 7. L6. All right reserved. for both ceiling .52 (Side view) 245 Suspension bolt pitch. • Be sure to secure a 600mm square opening for service and inspection as shown in the diagram below. anchor. Follow the procedure specified in the "CONNECTING THE WIRING" section to change the location. Inc. CAUTIONS • Once a screw-hole on the main unit has had a screw hammered in. • The installation location for printed wiring board can be changed.(This is to prevent condensation) • Be sure to install the unit with the ceiling-sie up.Installation Installation of The Main Unit NOTICE : • This unit has two different installation types: (1) Ceiling-suspended type and (2) wall-mounted type. Copyright ©2007 LG Electronics. (1) Ceiling-suspended type (2) Wall-mountde type (1) Ceiling-suspended type Procedure (1) Fix the fumished hanger metal with two screws. and ift the main unit to hang on the hanger metal. Screws(M5) (locally procude) (2) After checking with a level that the unit is level. the sound of refrigerant flowing through the piping may sometimes be audible.(4 locations in total). * The tilt of the unit should be within ±5° in front/back and left/right. (3 locations in total). tighten the hexagon nut. • Choose the proper installation pattern according to the location of installation. BD unit Six-sided Nut (M10 or M8) Hanger metal Flat washer 15. (3) Install a hexagon nut and a flat washer (locally-procured)to the hanging bolt as shown in the figure in the left. * The tilt of the unit should be within ±5° in front/back and left/right. make sure to either hammer it again or cover it with alumium tape. Only for training and service purposes . (4) After checking with a level that the unit is level.90 - LGE Internal Use Only . fix the unit with the furnished wood screws. * Block up the parts of hanger holes (2 places) by using insulation PE after installing the hanger. (2) Using an insert-hole-in. hang the hanging bolt. All right reserved. • Do not install near bedrooms.00 Hanging bolt (M10 or M8) (2) Wall-mounted type Procedure (1) Fix the fumished hanger metal with two screws. D) : For flaring work the piping. Align the center of the pipings and sufficiently tighten the flare nut by hand. 2. C. CAUTIONS • Never use the plastic cap for sealing.7 1/2 Ø15.5 6. 2. Overlap the connection pipe insulation material and the indoor unit pipe insulation material.Installation Connection of Piping • When connecting indoor units. 1. 3.52 3/8 Ø12. etc. Wrap the joint part with insulation.m 1. Align the center of the piping and sufficiently tighten the brass cap by hand. 2.05 3/4 Torque kg.6 Open-end wrench (fixed) Flare nut Wrench BD Unit Socket Connection pipe BD Unit Socket Flare nut Pipes Wrap the insulation material around the connecting portion. Wrap the area which accommodates the rear piping housing section with vinyl tape. (A. D) NOTICE : A B C D • Be sure to mark all the local refrigerant piping(liquid pipes. BD Unit Indoor unit pipe Wrap with vinyl tape Vinyl tape (wide) Connecting cable Pipe Vinyl tape(narrow) Close up a socket for unoccupied room with a brass cap.6 6. B. Tighten the flare nut with a wrench. B. BD Unit Socket Brass cap Pipe sealed or welded Copyright ©2007 LG Electronics. Outside diameter mm inch Ø6. Bind them together with vinyl tape so that there is no gap. Tighten the brass cap with a wrench.2 5.88 5/8 Ø19.35 1/4 Ø9. Only for training and service purposes .(A. NOTICE Connecting the pipings to the indoor unit and drain hose to drain pipe 1. C. gas pipes. Inc. 1.) for each indoor unit designating clearly which room it belongs in.91 - LGE Internal Use Only . make sure to connect refrigerant pipes and connection wires to the appropriate connection ports maked with matching alphabets. follow the instructions in the installation manual to each unit. All right reserved.8 4. • Make sure to use brass cap with the end of pipe sealed or welded tightly. Fix the wires completely with wire clamps(4 locations). and slide thecover in thedirection of thearrow. Follow the procedure below to install. Loosen the two screws. (3) Put in the cover in the direction of the arrow then tighten the screws. 2 and 3. fix the outer coating of wires securely with wire clamps. 1. Connection wire for indoor units (H05VV.2mm) (1) Remove the control cover. Allow 300 mm for the pulling-out section of harness. : The terminal board numbers are arranged from top to bottom in order of 1.Installation Connection of Wiring • Connect refrigerant pipes and connection wires to the appropriate ports maked with matching alphabets (A. 0.(See the figure below. or starbust connections. The wire clamp on indoor unit side is furnished. NOTICE In Case of 3 rooms Warning C room B room A room A B C CN-PWR Do not use tapped wires. extensioncords. 4wires. stand wires. 4wires. as they may cause overtheating. All right reserved. electrical shock. • Follow the instructions on the wiring nameplate to connect the connection wires of indoor/outdoor units to terminal board numbers.(1. Copyright ©2007 LG Electronics. 2 and 3) Always fix each ground wire separately with a ground screw. B and C) on this unit.92 - LGE Internal Use Only .75mm) Connection wire for outdoor units (H05RV. (2) Perform wiring with reference the wiring diagram on a control cover of outdoor unit. Only for training and service purposes .) • After completing the wiring. Inc. or fire. • Refer to the circuit diagram on the control cover inside outdoor unit. ➲ Setting Temp-0. While compressor is off fan operates at low speed regardless of the setting. operating with the airflow speed set by the remote control. I Heating Mode Operation • When the intake air temp reaches +3°…above the setting temp. 10-min dehumidification operation and 4-min compressor off repeat. the indoor fan repeats low airflow speed and stop. the intake air temperature is detected and the setting temp is automatically set according to the intake air temperature. I Soft Dry Operation Mode • When the dehumidification operation input by the remote control is received. Inc. the compressor is turned on.93 - LGE Internal Use Only . Compressor OFF Temp. 26°C ≤ Intake Air Temp ➲ 25°C 24°C ≤ Intake Intake Air Temp<26°C ➲ Intake Air Temp-1°C 18°C ≤ Intake Intake Air Temp<24°C ➲ Intake Air Temp-0. ➲ Setting Temp. off when sleep timer cancel or appliance operation pause Timer Indicator • On while in timer mode (on/off). When below the setting temp.5°C • In 10-min dehumidification operation. when above 27°C . ➲ Setting Temp+0. Compressor ON Temp.+3°C • While compressor on.. Only for training and service purposes . • While the intake air temp is between compressor on temp. and compressor off temp. All right reserved. the compressor is turned off. it Copyright ©2007 LG Electronics.5°C Compressor OFF Temp.5°C Compressor OFF Temp ➲ Setting Temp-0. ➲ Setting Temp.5 sec on) Sleep Timer Indicator • On while in sleep timer mode. the indoor fan is off when the indoor pipe temp. • When it reaches 0. MAIN UNIT FUNCTION • DISPLAY Operation Indicator • On while in appliance operation.5°C below the setting temp.5°C Intake Air Temp<18°C ➲ 18°C • While compressor off. the compressor and the outdoor fan stop. Compressor ON Temp ➲ Setting Temp+0. off while in appliance pause • Flashing while in disconnection or short in Thermistor (3 sec off / 0. they start to operate again.5°C above the setting temp. the indoor fan operates with the low airflow speed. is below 20°C.Operation Operation Function of control 1. off when timer mode is completed or canceled Defrost Indicator • Off except when hot start during heating mode operation or while in defrost control I Cooling Mode Operation • When the intake air temperature reaches 0. Compressor ON Temp.5°C • While in compressor running. • While in Fuzzy operation. the indoor is outdoor fans are turned off. • While in defrost control. when the intake air temp is 0. • When determining the operation mode. • The first defrost starts only when the outdoor pipe temperature falls below -6°C after 35 minutes passed from starting of heating operation and more than 4 minutes operation of compressor. when above 35°C . the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule.5°C • At the beginning of Fuzzy mode operation. Compressor ON Temp ➲ Setting Temp +0. Inc. All right reserved.5°C 18°C≤ Intake Air Temp<22°C ➲ Intake Air Temp Intake Air Temp<18°C ➲ 18°C • When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected. the compressor. • Defrost ends after 12 minutes passed from starting of defrost operation when the outdoor pipe temperature rises over 15°C even before 12 minutes. 26°C≤ Intake Air Temp ➲ 25°C 24°C≤ Intake Air Temp<26°C ➲ Intake Air Temp + 1°C 22°C≤ Intake Air Temp<24°C ➲ Intake Air Temp + 0. the mode before Fuzzy operation is operated. 1) Fuzzy Operation for Cooling • According to the setting temperature selected by Fuzzy rule.94 - LGE Internal Use Only . Only for training and service purposes .5°C or more below the setting temp. with the medium airflow speed). Then an operation mode is selected according to the intake air temp at that moment as follows. I Fuzzy Operation • When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since the operation off. When 0. and the 4 way valve are off and only the indoor fan is operated for 15 seconds.5°C or more above the setting temp. • The second defrost starts only when the outdoor pipe temperature falls below -6°C after 35 minutes passed from ending of the first defrost and more than 4 minutes operation of compressor. the airflow speed of the indoor fan is automatically selected according to the temperature.Operation operates with the low or setting speed. • While compressor off. the outdoor fan.5°C Compressor OFF Temp ➲ Setting Temp + 0. 24°C ≤ Inatake Air Temp ➲ Fuzzy Operation for Cooling 21°C ≤ Inatake Air Temp<24°C ➲ Fuzzy Operation for Dehumidification Inatake Air Temp<21°C ➲ Fuzzy Operation for Heating • If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10 sec or longer before Fuzzy operation. the indoor fan is off when the indoor pipe temp is below 33°C. it operates with Super-Low(while in sleep mode. it operates with the low airflow speed. the compressor is turned on. When the indoor pipe temp is between 20°C and 27°C. I Defrost Control(Heating) • Defrost operation is controlled by timer and sensing temperature of outdoor pipe. Copyright ©2007 LG Electronics. the operation mode is selected. the setting temperature is automatically selected according to the intake air temp at that time. the compressor is turned off. the appliance stops operating. the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. • If the appliance is operating at the time set by the timer.Operation 2) Fuzzy Operation for Dehumidification • According to the setting temperature selected by Fuzzy rule.5°C Compressor OFF Temp ➲ Setting Temp+0. 20°C≤Intake Air Temp ➲ Intake Air Temp + 0. When 0. Only for training and service purposes . the appliance starts to operate.5°C Intake Air Temp<20°C ➲ 20°C • When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected. the compressor is turned on. the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. medium. the compressor is turned on. the compressor is turned off. It is off when the time set by the timer is reached. the setting temperature is automatically selected according to the intake air temp at that time. the setting temperature is automatically selected according to the intake air temp at that time. or power (auto) by the input of the airflow speed selection key on the remote control. 3) Fuzzy Operation for Heating • According to the setting temperature selected by Fuzzy rule. All right reserved. • The timer LED is on when the off-timer is input.95 - LGE Internal Use Only . • While in Fuzzy operation. the compressor is turned off. When below the setting temp. I Airflow Speed Selection • The airflow speed of the indoor fan is set to high.5°C 18°C ≤ Intake Air Temp<22°C ➲ Intake Air Temp Intake Air Temp<18°C ➲ 18°C • When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected. 26°C ≤ Intake Air Temp ➲ 25°C 24°C ≤ Intake Air Temp<26°C ➲ Intake Air Temp+1°C 22°C ≤ Intake Air Temp<24°C ➲ Intake Air Temp+0. I Off-Timer Operation • When the set time is reached after the time is input by the remote control.5°C • At the beginning of Fuzzy mode operation. the operation continues. Copyright ©2007 LG Electronics. when the intake air temp is 3°C or more above the setting temp. • The timer LED is on when the on-timer is input. the pause continues. Inc. It is off when the time set by the timer is reached. Compressor ON Temp ➲ Setting Temp + 0. • While in Fuzzy operation. the airflow speed of the indoor fan repeats the low airflow speed or pause as in dehumidification operation. I On-Timer Operation • When the set time is reached after the time is input by the remote control. While in Fuzzy operation. the airflow speed of the indoor fan is automatically selected according to the temperature. • If the appliance is on pause at the time set by the timer.5°C or more above the setting temp.5°C or more below the setting temp. the airflow speed of the indoor fan is set to the high or the medium according to the intake air temperature and the setting temperature. when the intake air temp is 0. Compressor ON Temp ➲ Setting Temp Compressor OFF Temp ➲ Setting Temp + 3°C • At the beginning of Fuzzy mode operation. low. the Jet Cool mode has the priority. ventilation). Inc. the airflow speed of the indoor fan is set to the low. • While in cooling mode operation. dehumidification. I Jet Cool Mode Operation • While in heating mode or Fuzzy operation. • While the appliance is on pause. the upper/lower vane automatically operates with the Chaos Swing or they are fixed to the desired direction. I Chaos Swing Mode • By the Chaos Swing key input. the sleep timer mode cannot be input. the room temperature is controlled to the setting temperature. or low speed of the airflow mode is operated for 2~15 sec. the setting temperature increases by 1°C. the Jet Cool key cannot be input. • In the Jet Cool mode operation. the indoor fan is operated at super-high speed for 30 min at cooling mode operation. it increases by 1°C again. After another 30 min elapse. the airflow speed of the indoor fan is set to the medium. 18°C. All right reserved.4. Copyright ©2007 LG Electronics. randomly by the Chaos Simulation. Only for training and service purposes .2. • In the Jet Cool mode. I Auto Restarting Operation • When the power is restored after a sudden power failure while in appliance operation. the angles of cooling and heating cycle operations are different. medium. I Sleep Timer Operation • When the sleep time is reached after <1. the operation of the appliance stops.3. I Chaos Natural Wind Mode • When the Chaos Natural Wind mode is selected and then operated. the high. 30 min later since the start of the sleep timer.5. the mode before the power failure is kept on the memory and the appliance automatically operates in the mode on the memory. the upper/lower vanes are reset to those of the initial cooling mode and then operated in order that the air outflow could reach further.7. • When the Jet Cool key is input. • When the sleep timer mode is input while in heating cycle mode.6. • When the sleep timer mode is input while in cooling cycle mode.Operation I Off-Timer <=> On-Timer Operation • When the set time is reached after the on/off time is input by the remote control. the on/off-timer operation is carried out according to the set time.0(cancel) hr> is input by the remote control while in appliance operation.96 - LGE Internal Use Only . When it is input while in the other mode operation (cooling. • While in Chaos Swing mode. • When the sleep timer mode is input while in the Jet Cool mode operation. the Jet Cool mode is operated. High Speed Intake Air Temp<21°C ➲ Heating Mode Operation. or when the slide switch position is switched to the Auto Restarting (or test operation) position or switched from the remote control position to the forced operation position while the power is on. the forced operation selection switch is on the main unit of the appliance to operate the appliance in the standard conditions. 24°C.97 - LGE Internal Use Only . • In the forced operation mode. • When the slide switch position is switched from the forced operation position to the Auto Restarting position or the remote control position. High Speed 21°C≤Intake Air Temp<24°C ➲ Dehumidification Operation. Only for training and service purposes . 24°C≤Intake Air Temp ➲ Cooling Mode Operation. the short "beep-beep-" sounds. the forced operation is canceled and the appliance stops operating. Copyright ©2007 LG Electronics. All right reserved. the forced operation is carried out.Operation I Forced Operation • To operate the appliance by force in case that the remote control is lost. 23°C. the long "beep—" sounds. 22°C. • When the power is supplied while the slide switch is on the forced operation position. High Speed I Buzzer Sounding Operation • When the appliance-operation key is input by the remote control. Inc. • When the appliance-pause key is input by the remote control. the indoor fan is operated at low speed for around 15 sec and then the operation condition is set according to the intake air temperature as follows. . (THERMISTOR) Room temperature control • Maintains the room temperature in accordance with the Setting Temp. All right reserved. • The unit will be stopped after 1. 5.Lights up in Timer Mode --.Lights up in Sleep Mode --. Only for training and service purposes Deice (defrost) control (Heating) • Both the indoor and outdoor fan stops during deicing. Natural Air Control by CHAOS Logic • The fan is switched to intermittent or irregular operation • The fan speed is automatically switched from high to low speed. 6.98 - LGE Internal Use Only . 3.Lights up in Deice Mode Soft Dry Operation Mode • Intermittent operation of fan at low speed. Chaos Operation indication Lamps (LED) --.Lights up in operation --. Time Delay Safety Control • Restarting is delayed for approx. Hot-start Control (Heating) • The indoor fan stops until the evaporator piping temperature will be reached at 27°C. 2. Low. 4. 7 hours.Operation Function of Indoor Unit Split Type Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature • Room temperature sensor. Indoor Fan Speed Control • High. Sleep Mode Auto Control • The fan is switched to low(Cooling). Copyright ©2007 LG Electronics. Med. Starting Current Control • Indoor fan is delayed for 5 seconds at the starting. med(Heating) speed.(Model base) "Wall Mounted Type is standard" * Functions is dependent on model type. Inc. 3 minutes. * Airflow Direction Control • The louver can be set at the desired position or swing up and down automatically. • Hot start after deice ends. Natural Air Control by CHAOS Logic • The fan is switched to intermittent or irregular operation • The fan speed is automatically switched from high to low speed. Only for training and service purposes . 5. (THERMISTOR) Room temperature control • Maintains the room temperature in accordance with the Setting Temp. PLASMA • The function will be operated while in any operation mode with selecting the function.Lights up in operation --. Starting Current Control • Indoor fan is delayed for 5 sec at the starting. JET COOL Operation indication Lamps (LED) --. • The unit will be stopped after 1. Sleep Mode Auto Control • The fan is switched to low(Cooling).Lights up in Timer Mode --. Copyright ©2007 LG Electronics. med(Heating) speed. • The function is to be stopped while it is operating with selecting the function.99 - LGE Internal Use Only .Lights up in Defrost Mode (for Heating Model) OUTDOOR--. CHAOS. All right reserved. 2. Low. 7 hours. 4. 3 minutes.Lights up in compressor operation (for Cooling Model) Soft Dry Operation Mode • Intermittent operation of fan at low speed. Defrost(Deice) control (Heating) • Both the indoor and outdoor fan stops during defrosting. Hot-start Control (Heating) • The indoor fan stops until the evaporator pipe temperature will be reached at 28°C. Inc. 3. Indoor Fan Speed Control • High.Operation Art Cool Type Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature • Room temperature sensor. 6. Med. Airflow Direction Control • The louver can be set at the desired position or swing up and down automatically. Time Delay Safety Control • Restarting is inhibited for approx.Lights up in Sleep Mode --. Timer ON or Timer OFF Sleep Operation : 1. All right reserved. Inc. 5. Only for training and service purposes . 4.( Fan Speed Selection (Low) Room. Off Timer Airflow Direction Control 2nd F Air Circulation Reset : Fan Operates without cooling or heating. 3. ON. 2.Operation Art Cool Deluxe Type Remote Controller Operation ON/OFF Operation Mode Selection Cooling Operation Mode. Horizontal Airflow Direction Control Button(Optional) Copyright ©2007 LG Electronics.( ) ) Healthy Dehumidification Operation Mode. OFF ON OFF ON Timer Setting SET Timer Cancel CANCEL : Cancel Sleep Mode. 7. 6.100 - LGE Internal Use Only .( ) Heating Operation Mode. Temperature Checking (Med) (High) : (High:39°C Temperature Setting TEMPERATURE LOW HIGH Low:11°C) Cooling JET COOL Down to 18°C Up to 30°C Heating Down to 16°C Up to 30°C Setting the Time or Timer Timer Selection : OFF.( (Cooling (Heating model only) model only) ) Auto Operation Mode. 101 - LGE Internal Use Only . Inc. Only for training and service purposes .Operation Duct Type Remote Controller Operation ON/OFF Operation Mode Selection Cooling Operation Mode ( Heating Operation Mode ( ) ) Soft Dry Operation Mode ( Auto Operation Mode ( ) ) (Cooling (Heating model only) model only) Fan Speed Selection LO (Low) Room Temperature Display : High:39°C ↔ LOW:11°C Temperature Setting Cooling Setting the Timer Timer Cancel MED (Med) HI (High) Down to 18°C Up to 30°C Heating Down to 16°C Up to 30°C Weekly Program Program Week Holiday SET/CLR Hour Min Fan Operation Mode : Fan Operates without cooling & heating Phase Control Setting Timer Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes .Operation CST Type Remote Controller Operation ON/OFF Operation Mode Selection Cooling Operation Mode ( Heating Operation Mode ( ) ) Soft Dry Operation Mode ( Auto Operation Mode ( ) ) (Cooling (Heating model only) model only) Fan Speed Selection SLO (Super Low) Room Temperature Display : High:39°C ↔ LOW:11°C Temperature Setting Cooling LO (Low) MED (Med) HI (High) JET AUTO Down to 18°C Up to 30°C Heating Down to 16°C Up to 30°C Setting the Timer Timer Cancel Weekly Program Program Week Holiday : Fan Operates without cooling & heating SET/CLR Hour Min Fan Operation Mode Copyright ©2007 LG Electronics. All right reserved.102 - LGE Internal Use Only . Inc. ( ) Heating Operation Mode. 6. OFF ON Timer Setting SET Timer Cancel CANCEL : Cancel Sleep Mode. 2. Inc. 3. 5. Timer ON or Timer OFF Sleep Operation : 1. ON.( ) ) Healthy Dehumidification Operation Mode.( (Cooling (Heating model only) model only) ) Auto Operation Mode. Temperature Checking (Med) (High) (CHAOS) : (High:39°C Temperature Setting TEMPERATURE LOW HIGH Low:11°C) Down to 18°C Up to 30°C Down to 16°C Up to 30°C Cooling JET COOL Heating PLASMA(Optional) Setting the Time or Timer Timer Selection ON OFF : OFF. Only for training and service purposes .103 - LGE Internal Use Only . All right reserved.Operation Convertible Type Remote Control Operation ON/OFF Operation Mode Selection Cooling Operation Mode. Off Timer Airflow Direction Control Air Circulation : Fan Operates without cooling or heating. 7.( Fan Speed Selection (Low) Room. Horizontal Airflow Direction Control Button(Optional) 2nd F Reset Copyright ©2007 LG Electronics. 4. Heat Sink Temp. Only for training and service purposes . in this case.Operation Function of Outdoor Unit Outdoor Unit Two Comp algorithm • Inverter Comp is first priority and then Constant Comp is turning on responding to load condtion. check the defrost condition and if outdoor pipe temp is below -6°C and released from deice operation in case outdoor pipe temp is over 15°C or 7 min cooing mode. operate compressor at low frequency upto 5min to preheat oil. D-Pipe temp. down comp Hz.3kgf/cm2). IPM Over Heat Protection • To protect IPM overheat. changes from heating to cooling for 5 min to return the oil in piping to compressor. All right reserved. R/Valve Control • Convert R/Valve to change cooling to heating. Copyright ©2007 LG Electronics. Comp Overload Protection • To protect comp from being overload. operating room number. turn off comp and outdoor fan. Comp Pre-Heat Logic • Checking outdoor temp. convert operating mode from heating to cooling. Out door Fan Control • Outdoor fan operates at High/Low or Off to respond to the load condition. Operating Frequency • Inverter Frequency varies considering condition such as room temp. Inc. down comp Hz. Low Pressure Protection • If cylce pressure is low (around 0. LEV Control • LEV pulse is modulated to keep constant superheat or subcooling. every 3 hours. Oil Return System • In heating operation.Temp gap between room temp and set temp and so on.104 - LGE Internal Use Only . Defrost Function • After 35 min heating operation. indoor and outdoor fan is off. • To deice outdoor heat exchanger in low temp condtion.outdoor temp. heating to cooling. ) • Cooling Model( ). Operation Mode Cooling Operation Auto Operation 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. 15 2nd F Button Used prior to using modes printed in blue at the bottom of buttons. high and CHAOS. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low.105 - LGE Internal Use Only . TIMER SET/CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation. 1 Signal transmitter START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. 16 AUTO CLEAN (Model Base) Used to set Auto Clean mode. Only for training and service purposes . Heat Pump Model( 14 RESET BUTTON Initialize remote controller. TIME SETTING BUTTONS Used to adjust the time. All right reserved. OPERATION MODE SELECTION BUTTON Used to select the operation mode.Operation Remote Control Operation The Remote Controller transmits the signals to the system. ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. medium. Inc. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. JET COOL Used to start or stop the speed cooling/heating. Healthy Dehumidification Operation Heating Operation 13 PLASMA(OPTIONAL) Used to start or stop the plasma-purification function.) CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. Copyright ©2007 LG Electronics. 17 HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (OPTIONAL) Used to set the desired horizontal airflow direction. 2 3 4 5 6 1 3 4 2 7 11 8 13 14 10 CANCEL ON OFF SET AUTO CLEAN 5 6 9 16 7 12 15 17 Flip-up door (opened) 8 9 10 SLEEP MODE AUTO BUTTON 11 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating. Used to set Sleep Mode Auto operation. (Speed cooling/heating operates super high fan speed. Time Set Button Used to set the time of the day and change the time in the weekly timer Function.Operation Duct Type Remote Controller AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO SUB FUNCTION 2ndF Timer On Off Set no. Holiday Button Used to set a holiday of the week. • Auto Operation Mode • Cooling Operation Mode • Soft Dry Operation Mode • Heating Operation Mode(except cooling model) Room Temperature Checking Button Used to check the room temperature. Inc. FAN Operation Button Used to circulate room air without cooling or heating. 5 6 7 8 Copyright ©2007 LG Electronics. Timer Cancel Button Used to cancel the timer. and stops when the button is pressed again. Reset Button Used to set the current time and clear the setting time. All right reserved. Set and Clear Button Used to set and clear the weekly timer. Program Button Used to set the weekly timer.106 - LGE Internal Use Only . Fan Speed Button Used to set the desired fan speed. Week Button Used to set a day of the week. 9 10 11 12 13 14 15 Timer Set Button Used to set the timer when the desired time is obtained. Operation Mode Selection Button Used to select the operation mode. Time 01 Time AUTO Heater Preheat JET Defrost Humidify SLo Filter Out door ZONE 1 2 3 4 17 19 21 23 1 Operation unit No Func Program set 03 05 07 09 11 13 15 3 Signal receptor 8 9 10 11 12 13 14 2 5 Timer Cancel 2ndF Program Week Holiday PLASMA 6 AUTO Set/Clr Hour Min RESET 4 7 15 1 2 3 4 Operation display Displays the operation conditions. On/Off Button Operation starts when this button is pressed. Only for training and service purposes . Set Temperature Button Used to set the temperature when the desired temperature is obtained. Auto Swing Button Jet Cool Button Used to swing up and down/right and left(option) Auto Swing Button(1 Way 06 Model) Room Temperature Checking Button/Filter sign 18 Reset Button Release(Option) Used to set the current time and clear the setting time. Note : 06 Model . Used to set a day of the week. Time 01 15 3 17 10 11 12 13 14 15 16 18 Timer Cancel 2ndF 2 5 6 4 7 8 9 Program Week Holiday Plasma Set/Clr Hour Min RESET 1 Operation display 9 Plasma Air Clean Button (Option)/Heater(Option) 10 Timer Cancel Button Displays the operation conditions. AMNH12GTCC0 Copyright ©2007 LG Electronics. Inc.AMNH09GTCC0. Fan Speed 14 Holiday Button Used to set the desired fan speed or select Jet cool Used to set a holiday of the week. Used to check the room temperature. 11 Timer Set Button Operation starts when this button is pressed. mode. • Auto Operation Mode 16 Set and Clean/Ventilation(Option) • Cooling Operation Mode Used to set and clear the weekly timer.Operation CST Type Remote Controller AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO SUB FUNCTION 2ndF Timer Operation unit 03 Time Program set 09 11 13 AUTO Heater Preheat JET Defrost Humidify SLO Filter Out door ZONE 1 2 3 4 17 19 21 23 1 No Func 05 07 On Off Set no. and stops when the button is pressed again. 15 Time Set Button Operation Mode Selection Button Used to set the time of the day and change the time in Used to select the operation mode. the weekly timer Function. Only for training and service purposes . All right reserved. 4 5 6 7 8 Used to set the temperature when the desired temper12 Week Button ature is obtained. FAN Operation Button 13 Program Button Used to circulate room air without cooling or heating. 3 Set Temperature Button Used to set the timer when the desired time is obtained. 2 On/Off Button Used to cancel the timer. • Soft Dry Operation Mode • Heating Operation Mode(except cooling model) 17 Swirl Button Used to select swirl mode. Used to set the weekly timer. ❈ Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source.107 - LGE Internal Use Only . • Maunfactured in the position 1. (3) Move the slide switch to set position. • Position 1: The room temperature is controlled by the thermistor of the main body. CAUTION: • Select the position after counselling with a customer. Only for training and service purposes . control the temperature according to the position of wired remote-controller. • Position 2: The room themperature is controlled by the thermistor of the wired remote-controller.108 - LGE Internal Use Only . • Position 3: The room temperature is controlled by lower temperature between the temperature of main body and of remote-controller sensor. install controller(room temp. (2) Select one of three selectable modes as follows. All right reserved. • To control the room temperature by a wired remote controller. • In case of cooling mode. sensor Slide switch for 2 Thermistor TH R13H R12H CO1H OP5R16H OP4 R14H OP3 SW TH OP2 OP1 R19H R11H R15H Position 2 Position 1 Position 3 REMO MAIN 2TH SW REMO MAIN 2TH R17H OP7 R18H OP6 LO STAND HI C070 R03S R04S R02S R01S HIGH (4) Close the rear cover and check if it works normally. Copyright ©2007 LG Electronics. Room Temp. sensor) to sense the temperature more accurately. room temperature is controlled by the main body sensor.Operation 1) Two Thermistor System (1) Open the rear cover of the wired remote-controller to set the mode. Inc. • Use a wire more than 0. Inc. Time 01 Wired Remote Controller OP7 Remote Controller PCB Features • Use Only One Wired Remote Controller with several air conditioners(max. YL(SIGNAL) BR(GND) YL(SIGNAL) BR(GND) Main PCB #16 ..5mm2 Copyright ©2007 LG Electronics. Connecting Cable(Local Supply) AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO ZONE SUB FUNCTION Time Timer Operation unit 03 05 07 AUTO Heater Preheat JET Defrost Humidify Filter Out door 1 2 3 4 19 21 23 Slide Switch Program set 09 11 13 15 17 On Off Set no. and each Unit starts sequentially to prevent overcurrent.. CAUTION: • Be careful not to exchange the color of wires. All right reserved. 16 Units) • Random starting to prevent overcurrent. Wiring design Indoor Unit 1 Terminal(Local Supply) Block Connector RED(12V) YL(SIGNAL) BR(GND) RED(12V) YL(SIGNAL) BR(GND) Main PCB Indoor Unit 2 Terminal(Local Supply) Block Connector YL(SIGNAL) BR(GND) YL(SIGNAL) BR(GND) Indoor Unit 16 Terminal(Local Supply) Block Connector Main PCB #1 Main PCB #2 . • The maximum length of connecting wire should be below 200m(25Ω) on connecting each units.109 - LGE Internal Use Only .Operation 2) Group Control(Optional Wiring) • You can use a group control operation after connecting the brown and yellow wire of each air-conditioner.... Only for training and service purposes .. • It operates maximum 16 Units by only one Wired Remote Controller. • Remove the resistor "OP 7" in remote controller. Position V-L: • This position sets the minimum E. Position V-L: • Minimum E.S. Only for training and service purposes .P as a default set. Position V-H.S.S.(External Static Pressure) Setting (1) Open the rear cover of the wired remote-controller to set the mode. 2. Copyright ©2007 LG Electronics. Inc. 2. F-H: • This position sets the maximum E. Position F-H: • Maximum E. All right reserved.110 - LGE Internal Use Only .P setting & Fan speed is varied according to the state of dampers by micom. TH R13H R12H CO1H OP5R16H OP4 R14H OP3 SW TH OP2 OP1 R19H R11H R15H V-H F-H V-L REMO MAIN 2TH R17H OP7 R18H OP6 LO STAND HI C070 R03S R04S R02S R01S SW HIGH Slide switch for ceiling height (4) Close the rear cover and check if it works normally.Operation 3) E.P setting & Fan speed doesn't vary according to the opening & Closing of dampers.P. I Without Zone System 1.S. I With Zone System 1.P setting & Fan speed is varied according to the state of dampers by micom.P as a default set.S. Position V-H: • Maximum E.S. * Maximum : 8mmAq Minimum : 0mmAq (3) Move the slide switch to set position. 3. (2) Select one of three selectable modes as follows. 4 Shift the fan speed mode by pressing the fan speed button. (In this example.S. And then. Time 01 03 05 07 Program set 09 11 13 15 17 19 21 23 3 Push the "Up" of "Down" button for E. AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO ZONE SUB FUNCTION Timer Time Operation unit Set no. adjust the number which you want.S. Refer to the table 1 on the next page. Since. If the range selection is above 100 then the third digit will appear in the screen as shown. All right reserved. Adjust numbers of next steps by repeating the stage 3.P adjustment.) AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO SUB FUNCTION Time Operation unit Set no.P? Procedure of RPM change: Ex) External Static pressure is 4mmAq for Model 36K. Time 01 03 05 07 AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 2 17 19 21 23 Program set 09 11 13 15 Note: The range of selection is from 1~254. the numbers are "237" and "243" respectly) 5 Push the "Timer" and "Wind" button simultaneously for more than 3 seconds.P. 1 Push the"On/Off"button. Wind Data is memorized by the EEPROM of the main PCB. • To protect the unit.Operation 4) How to Set E. AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO ZONE SUB FUNCTION AUTO Heater Preheat JET Defrost Humidify Filter Out door Time Operation unit Set no. compressor is designed to be off during E.(In this example. the display is two Digit only. setting. Inc. Then. Only for training and service purposes . the number is "225". Timer AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO ZONE SUB FUNCTION AUTO Heater Preheat JET Defrost Humidify Filter Out door Time Operation unit Set no.111 - LGE Internal Use Only . The unit will start. Time 01 03 05 07 AUTO Heater Preheat JET Defrost Humidify Filter Out door Program set 09 11 13 15 17 19 21 23 Copyright ©2007 LG Electronics.S. Time 01 03 05 07 Program set 09 11 13 15 17 19 21 23 2 Push the "Timer" and "Wind" button simultaneously for more then 3 seconds. And. Operation Duct ESP control table Chassis Static Pressure(mmAq) 0 1 Setting Value 220 240 255 175 200 220 170 185 220 0 215 235 250 170 190 215 150 165 180 2 Setting Value 225 245 254 210 235 254 2 4 220 240 253 200 230 215 6 Setting Value 235 245 254 220 235 250 0 230 238 252 205 230 240 2 225 235 248 190 220 235 4 215 230 245 170 200 230 6 Setting Value 153 173 195 230 240 245 150 173 195 230 238 245 150 175 193 225 237 243 148 175 193 220 235 243 130 170 190 150 230 240 1 155 190 1 220 240 180 215 240 1 100 210 8 10 8 210 230 250 100 220 245 10 210 230 245 150 185 210 130 145 160 4 2 Ca(Btu/h) 9k Step(Hi/Med/Lo) 8 CMM 7 CMM 6 CMM 10 CMM BT 12k 9 CMM 8 CMM 14 CMM 18k 13 CMM 12 CMM Chassis Static Pressure(mmAq) Ca(Btu/h) 9k Step(Hi/Med/Lo) 10.5 CMM 9 CMM 8.5 CMM 11.5 CMM BP 12k 10 CMM 8.5 CMM Chassis Static Pressure(mmAq) 0 Ca(Btu/h) Step(Hi/Med/Lo) 16.5 CMM 18k 14.5 CMM 13 CMM 18 CMM 24k 16.5 CMM 14 CMM Chassis Static Pressure(mmAq) BH Ca(Btu/h) Step(Hi/Med/Lo) 26.5 CMM 30k 23 CMM 20 CMM 32 CMM 36k 29 CMM 26.5 CMM BG Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 112 - LGE Internal Use Only Operation Chassis Static Pressure(mmAq) 0 1 2 Setting Value 3 4 Ca(Btu/h) 9k Step(Hi/Med/Lo) 8.5 CMM 7.5 CMM 6.5 CMM 9.5 CMM 75 69 62 82 75 69 90 82 75 110 100 90 84 77 71 90 84 77 97 90 84 117 107 97 94 88 83 99 94 88 105 99 93 125 115 105 104 99 95 109 104 99 114 109 103 129 121 114 114 110 106 118 114 110 122 119 114 127 122 B1 12k 8.5 CMM 7.5 CMM 15 CMM 18k 13.5 CMM 11.5 CMM 17 CMM B2 24k 15 CMM 13.5 CMM Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 113 - LGE Internal Use Only Control Devices and Function Control Devices and Function Simple Central Control Features • Easy operation button. • Independent operation for 16 indoor units each. • Simultaneous turn ON/OFF for all of indoor units connected. • Easy change operation mode to cooling or heating • Set and clear lock-mode for each indoor unit • Simultaneously set and clear lock-mode for all of indoor units connected. • Display function for all of indoor units connected. Term of Each part and Function On/Off display LED (TOTAL 16EA) • On pressing individual on/off button, display the present operation state. -Operation : green. -Stop : off -Error mode : blinking Individual On/Off button • Control ON/OFF of a unit. Power display LED • Indicate the state of DC Power supply in central control unit. - On : red(Heating), green(Cooling) - Off : no signal - Error mode : blinking with red color TOTAL Off button • Stop all linked units sequentially. TOTAL On button • Operate all linked units sequentially. Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 114 - LGE Internal Use Only Control Devices and Function Electrical wiring I PICTORIAL VIEW OF THE CONNECTION Outdoor Outdoor unit unit PI485 MAIN PCB L : PNF-P14A0M PI485 MAIN PCB CN_CENTRAL Control Box MAIN PCB CN_CENTRAL N L PI485 10 G A B VCC GND C D CN OUT CENTRAL CONTROL UNIT • Special purchase: Central control, PI485(PNF-P14A0M) I ONE SIMPLE CENTRAL CONTROL CONNECTION INDOOR UNIT 1 INDOOR UNIT 2 INDOOR UNIT • SET The Address(Group No. & Indoor No.) * Refer to The Following sheet (1.3.5 Indoor unit Address setting method) Vcc GND C D OUTDOOR MAIN PCB INDOOR UNIT 3 INDOOR UNIT 4 INDOOR UNIT 5 INDOOR UNIT 6 BUS B BUS A GND +10V CN-POWER GND CN-COM B CN-POWER S1 LED2 LED3 IC1P + + LED5 + S9 S5 + S6 LED4 S2 L CN-COM A S4 + LED7 + LED8 S11 S3 D C GND VCC TX1 S12 + LED10 S10 + LED11 Outdoor Outdoor unit unit Group Number 0 Master Mode LED9 LED12 S15 + LED13 + LED14 S14 + LED15 + LED16 S16 PWB:6870A10001A ASM:6711A20005E + LED17 ON KSDO4H L1 2 3 4 S19 S15 S18 All the connections are to be done as shown above. A and B are the communication lines for the indoor and C and D are the communication lines for the Central Control. Use two shield lines for C/D connecting line.(Earth the shield line) VCC CENTRAL GND CONTROL C UNIT D Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 115 - LGE Internal Use Only Control Devices and Function I 2 OR MORE SIMPLE CENTRAL CONTROL CONNECTION INDOOR UNIT 1 INDOOR UNIT 2 OUTDOOR MAIN PCB INDOOR UNIT 3 INDOOR UNIT 4 <Group Number 0> INDOOR UNIT 5 INDOOR UNIT 6 BUS B BUS A GND +10V IC1P + LED5 + LED9 S9 Vcc GND C CN-POWER GND D CN-COM B CN-POWER S1 LED2 LED3 S5 + S6 LED4 S2 L CN-COM A S4 Master DIP SWITCH + LED7 + LED8 S11 S3 TX1 S12 + LED10 S10 + LED11 LED12 S15 + LED13 + LED14 S14 + LED15 + LED16 S16 D C GND VCC PWB:6870A10001A ASM:6711A20005E + LED17 ON KSDO4H L1 2 3 S19 4 S15 S18 Outdoor unit 1 INDOOR UNIT 1 INDOOR UNIT 2 Master Mode Group Number 0 1. Adhere the PI485 Module(For connecting central control) to the Control Box. 2. Connect the PI485 Module to central control. 3. In the case of connecting two more than central control, set the Master/Slave mode and then connect each communication lines(C,D) <Refer to above fig>. *Special purcharse: Central control(P/No.:4995A20105F), PI485 Module(PNF-P14A0M) * It can be added to 15 Central controls for the slave control. OUTDOOR MAIN PCB INDOOR UNIT 3 INDOOR UNIT 4 INDOOR UNIT 5 INDOOR UNIT 6 BUS B BUS A GND +10V IC1P + LED5 + LED9 S9 Note <Group Number 1> Vcc GND C CN-POWER GND CN-COM B CN-POWER S1 LED2 LED3 S5 + S6 LED4 S2 L CN-COM A S4 D 001 Slave DIP SWITCH Group No. Indoor No. TX1 + LED7 + LED8 S11 S3 + LED10 S10 + LED11 S12 LED12 S15 + + LED14 S14 + LED15 + LED16 S16 D C GND VCC LED13 PWB:6870A10001A ASM:6711A20005E + LED17 ON KSDO4H L1 2 3 S19 4 S15 S18 Outdoor unit 2 Master Mode Group Number 0 PI485 setting method(LG Aircon Network unit) Selection of product unit type Selection of network type ON KS DO 4H L1 2 3 4 I Settings method of TPS Inverter Multi Type ON KS DO 4H L1 2 3 4 1 ON + All OFF : Connection of "TPS Inverter Multi Connection + General Central Controller" Case. ON KS DO 4H 1,4 ON + All OFF : Connection of L1 2 3 4 "TPS Inverter Multi Connection + Central Controller applied 「LGAP」" Case. * LGAP : LG Air conditioners Protocol • Function of LG Network - It is possible to connect the network of LG air conditioners and to connect various contents of the network system, which is simple, deluxe and PC central control. - Please refer to "LG Control System Manual" about the detail functions and the products possible to network. - As the Interface for networking, PNF-P14A0M/R/C is applied. Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes - 116 - LGE Internal Use Only No. 2) At the address monitoring mode.Control Devices and Function Indoor Unit Address setting Method Using Wired Remocon AUTO SWING OPERATION SET TEMP Room Temp FAN SPEED HI MED LO SUB FUNCTION 1. Address setting Method Signal transmitter 1) Press 5(Jet Cool) & 13(Reset) key at the same time more than 3 seconds then "Address Setting Mode" starts. * Notice : Confirm that wired and wireless remote control are able to select the address or not. Inc. 2) Set the address of indoor unit by using "Temperature setting" key. Flip-up door (opened) 2. 2. The address that is set is displayed on a display window of indoor unit. I Range of address : 00 ~ FF 1 Time Timer Operation unit 03 05 07 AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4 17 19 21 23 Program set 09 11 13 15 On Off Set no. Time 01 3 17 10 11 12 13 14 15 16 18 Heat Pump Model Timer Cancel 2 5 Holiday Plasma Set/Clr Hour Min RESET Ex) 3 A Program Week 6 4 7 8 9 Group Room(Indoor Unit) No. After setting address. Set the address of indoor unit by using "Temperature setting" key. 3) If the remote control is reset. press 13(program) and 16(set and clear) key more than 3 second then "Address Setting Mode" is finished. The address that is set is displayed on a display window of indoor unit. Only for training and service purposes . address setting is finished. * notice : The mothod of display and time is different according to indoor unit type. Press 13(program) and 16(set and clear) key more than 3 second then "Address Setting Mode" starts. Address Monitoring 1) Press 6(Chaos Swing) & 13(Reset) key at the same time then "Address Monitoring Mode" starts. 3. * notice : The mothod of display and time is different according to indoor unit type. 2.117 - LGE Internal Use Only . normal mode starts. 3) After address setting. 4) If the remote control is reset. pressing 1(On/Off) key. pressing 1(On/Off) key. Using Wireless Remocon 1. All right reserved. No. normal mode starts. Copyright ©2007 LG Electronics. I Range of address : 00 ~ FF 5 6 1 3 Ex) 3 A 4 2 7 11 8 13 14 10 CANCEL ON OFF SET AUTO CLEAN 9 16 12 15 Group Room(Indoor Unit) No. Do auto addressing to the outdoor unit. Copyright ©2007 LG Electronics. Keep in mind • Don’t operate with wet hands. 4. • Don’t install near high moisture & high oscillation area. computer. Inc. • Don’t install near direct sunlight or heat source. Set the wiring of system and indoor unit. Check up On/Off with a related indoor key pressing. initialize the central controller(Manual initialize: Total on + total off + 16 key). (High noise area). Apply power to the setting. 3. automatic door. Installation I CAUTIONS Do not install in this area • Don’t install near elevator. • Don’t pull the connected wire. After addressing.118 - LGE Internal Use Only .Control Devices and Function Test run method 1. • Cooling: Setting basically(Total On + Total Off + 4 key) • Heating: Total On + Total Off + 8 key ➡ Red power lamp 'On' 6. All right reserved. Only for training and service purposes . 2. link the connecting wire. For Dip switch. Only for training and service purposes . 2. 6. I LINK OF CONNECTING WIRE 1. GND on PCB referring to the following table. connect terminal C. refer to the page “How to Install”. Adjust the upper case in accordance with back case while assembling as shown in the figure. 4. D. For wiring connection. Check the operation by supplying the power.Control Devices and Function I INSTALLATION ORDER 1. Copyright ©2007 LG Electronics.119 - LGE Internal Use Only . First. Fixate screw in the holes of the case bottom.Vcc. refer page “Installation Procedure” 5. 3. Inc. separate the front case from rear case of controller. Cut the indicated part of front case to draw the lead wire. After attaching the supplied wire to terminal. Remove upper & lower case. If necessary. All right reserved. Maximum length of connecting wire • Between controller and outdoor unit : 220m(25Ω • Between controllers : 220m(25Ω ) ) Vcc GND D C Out door unit Terminal Block GND Vcc C D Wire Color BLUE Red Brown Yellow Central Control Terminal GND Vcc C D 2. and Rotary switch setting. I. DIP SWITCH SETTING(INSTALLATION FOR 2 OR MORE SIMPLE CENTRAL CONTROL) CAUTION Dip switch is now used only for the setting of master or slave mode.120 - LGE Internal Use Only . ROTARY SWITCH SETTING(INSTALLATION FOR 2 OR MORE SIMPLE CENTRAL CONTROL) The setting of Group Number in the Central Control is done by the rotary switch as shown in the figure below. Similarly we can control all the 16 Groups. All right reserved. the others to slave. ACCEASSORY PARTS Central control and sub (with wire ass'y) should be purchased as optional.) Set one to Master. Only for training and service purposes . The above fig. All the numbers on the rotary switch represent the different Group Numbers. Central Control(1EA) PI485(PQNFP14A0M) Wire Assembly 1 Screw(4EA) Wire Assembly 2 Copyright ©2007 LG Electronics. Shows the control of group number “0”. It is possible to set 0~15 Group(Total 16 Groups).Control Devices and Function I. Inc. Master Mode Rotary Switch Dip Switch ON OFF Slave Mode I. By changing the knob we can set rotary switch to the group number we want to control.( In the case of two more than central controls. Inc. more efficient operation at the center is available. All right reserved. Specially for this system. With this setup. user locking and temperature setup are also available. this system have the self-battery built-in and can stably operate in spite of outside disturbance such as temporary power failure. you may control the system by using the wire/wireless remote control at the place where the individual air conditioner is installed. In addition. Deluxe Central control Outdoor Unit CNU PI485 Outdoor Unit PI485 Copyright ©2007 LG Electronics. Individual or simultaneous operation of the air conditioner. In case of releasing the lock.1. Only for training and service purposes . and has so attractive advantage in installation costs. Where needs from a new customer occur or where purchase of additional air conditioner is done. installation is simple and user's environment is excellent. wind quantity. Specially. Using the Deluxe Central control enables the management room to setup lock of each air conditioner and prevent indoor control of the individual air conditioner and restrain the necessary use. the Deluxe Central control can be smoothly installed. Central control is available by a simple manipulation. Setup without requiring other equipment is available by using the GUI and change by the consumer is also available after installation. Depending on installation environment. You can reduce development time to configure special system upon the request by the consumer and conveniently this system by using the touch panel. operation mode. operation status of the individual air conditioner can be particularly checked. location and conditions of use.1 Summary Deluxe Central control is a product available for individual and integrated monitoring and control of maximum 256 of TPS Inverter Multi air conditioner systems.Control Devices and Function Deluxe Central Control 2. This system has no need of additional peripheral equipment like UPS (Undisturbed Power System) and AVR to be purchased for stability when composing the existing PC central control system. Details of schedule setup can be immediately checked with a graph. This system is a product to meet energy saving and convenience at the same time at a place like a school by using this schedule function. Setup of a weekly schedule is available and detailed schedule of the individual air conditioner can be easily setup through the GUI.121 - LGE Internal Use Only . you can setup groups. Copyright ©2007 LG Electronics. Semi-permanent Life / Convenient Maintenance I Since the Deluxe Central control is designed for the semi-permanent use. 5. 2. there is only function of on/off management at best and thus 2 or 3 building managers were actually required. location and size of each air conditioner which enables convenient use. In addition. Self-diagnosis Function I The air conditioner installed can self-diagnosed its error status and then transmits the result to the central control. Group Management I Group management for the installed air conditioners is available. even if management was done at the center. Group can be seperated by their nature. a rapid countermeasure against failure of the air conditioner allows easy management and increases the usage life of air conditioner.122 - LGE Internal Use Only . 3. the manager controls a number of air conditioners. is a convenient way. group selection or all selection. temperature setting and error. wind quantity. etc by selecting the installed air conditioner through individual selection.Control Devices and Function Major Characteristics Figure 2) Deluxe Central control 1. However. Therefore. In addition. different from the existing PC or a large central control system requiring a continuous management due to the life of peripheral and other PC. this system can be used semipermanently after installation. Management Costs Down I In absence of the Central Control System. Individual setup and operation of the detailed functions are available. allotment of respective name to the setup group allows further intuitive management. manipulation of all functions can be now done at a control room for the Deluxe Central control and so a manager can easily control all air conditioners. Therefore. Inc. locking. managing with Deluxe Central control installed at the control room at a building where a number of air conditioners are installed. wind direction. All right reserved. Individual/Integrated Operation/Monitoring I You can identify operation status of the air conditioner. Only for training and service purposes . by using schedule function. Automatic operation is also allowed without a manager. 4. operation mode. CF Type is prepared. Only for training and service purposes . Convenient Installation I This system can be freely fixed to the wall surface because of its small size. Fixed schedule places like elementary school. It can also stood up on the desk by using. 9. conveniently used only by pressing the buttons on the screen.123 - LGE Internal Use Only . Power Failure Backup Function / Powerful Stability I For the existing Central Control System. Inc. Serial (RS-232c). power is automatically converted by maximum 2 hours. 11. PCMCIA. high school and college or university will get its excellent working effect. Stable Date Storage/Backup I Setup information is saved as it is. All right reserved. its dedicated cradle. Scalability I Scalability of the system is easy in case of additionally purchasing equipment since scalable slot such as USB. Schedule Automatic Operation Management / Energy Saving I For the Schedule Automatic Operation. weekly setting is available. there is almost no malfunction due to a temporary power failure because stable operation is available.Control Devices and Function 6. 7. Especially schedule setting is done by simply by dragging. Upgrade I Additional installation of a new program is available via the CF memory card and the existing program can be upgraded to a new program. 8. since the self-power failure compensation battery is built-in. even if no power is supplied then also all data is saved in the built-in flash memory. and its function can be understood with intuitive pictogram. additional purchase of expensive UPS equipment in provision for a temporary power failure must be done in the past but for the Deluxe Central control. Therefore. it will control the Airconditioners directly while going around the building with the wireless radio system and its self-battery function (100 m where there is no obstacle). middle school. Enlisting of the schedule exception processing schedule (national holiday) is done for a year prevents the air conditioner from an unnecessary operation of air conditioner. allowing the system to be controlled at the center so that it can be only used for a necessary case and enabling to obtain excellent energy saving effect. Copyright ©2007 LG Electronics. 13. different from the existing system requiring to press the button by more than average 30 times to enter a schedule. 12. 10. This system is designed considering sufficient scalability in provision for special request by the customer. Mobility I A wireless radio system may be installed at the Deluxe Central control. Using such upgrade function always enables to construct a modern type of Central Control System. It is not subjected to spatial restriction in installation space and location since this system communicates on the basis of the I-GW and the Ethernet. Convenient GUI / Touch Screen I Not requires special education for using the Deluxe Central control. light weight and thin thickness. installation set numbers may respond up to 1024 sets upon user’s request. Copyright ©2007 LG Electronics. Only for training and service purposes . installation set numbers Remote control Control & monitoring Schedule management System setup System monitoring(overview) User ’s lock Upgrade Touch screen Built-in Flash DB (backup) Wireless LAN (movable) Non-interruption device Requirements Life Non-required User S/W Download to i-GW 256 sets (Less than 128 sets recommended) Available Available Available(Configure file modification) Available Available Browser supporting JAVA Semi-permanent PC Central control Required User S/W.Control Devices and Function Figure 3) Deluxe Central control Table 1) Comparison Between Central control Characteristics Internet Central control Dedicate PC Configuration Position of program Max. Inc. All right reserved.124 - LGE Internal Use Only . Engine S/W Installation 256 sets1) Available Available Available Available Available Available Separately add 2) JVM (provided by MS) Peripheral devices & PC life Deluxe Central control Non-required Main Body of Web Pad Deluxe Central control Built-in 256 sets Available Available Available Available Available Available Built-in Built-in Available (option) Built-in Semi-permanent 1) For the PC central control. 2) JVM (Java Virtual Machine) is basically installed at the Windows but some versions of Window XP may be manually installed. PQCSW502A0 [ Time Schedule ] Setup of a weekly schedule for all. group and individual air conditioner enabled operation of the system. Processing through enlist of extra schedule for a year is available. PQCSW501A0. All right reserved.Control Devices and Function Major Function of Deluxe Central Control [ System Control ] To check general monitor function of the air con central control system such as selection of group and air conditioner. PQCSW502A0 [ System Monitor ] To check the ctual time status of all air conditioners. air conditioner control monitor function etc. Inc. PQCSW502A0 [ System Set-up ] To manage the air conditioner through grouping and record setup of group and installation position.125 - LGE Internal Use Only . Only for training and service purposes . PQCSW501A0. PQCSW502A0 Copyright ©2007 LG Electronics. PQCSW501A0. etc. for improvement or options.Centralized control of maximum 256 indoor units . PI485 . Only for training and service purposes . Control System . Main Specifications 1.1 pcs per outdoor units Note: .Simple Touch PAD method . Copyright ©2007 LG Electronics.485 to Ethernet Converter Built-in 3.GUI setting considering convenience of use .GUI(Graphic User Interface) may be changed without any notice.Combination of maximum 8 outdoor units . Inc.Power failure compensation with independent Battery Built-in (Max. All right reserved. CNU .126 - LGE Internal Use Only .Control Devices and Function System Configuration Scenario 1 : In case of not using Internet access function B part A part Product Control System Interface Delux Central Control CNU PI485 PI485 Cross UTP Cable (Cross LAN Cable) RS-485 Cable PI485 PI485 * CNU: Central control Network interface Unit PI485: Product Interface unit for IEEE485 transmission. 2 hours) 2. earth conductor & step motor conductor with sensor holder. • Remove the securing screws • To remove the Grille. Motor. Inc. housing connect. Be sure the power switch is set to “OFF”. Screw 1) To remove the sensor. pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward. • Set the up-and-down air discharge louver to open position (horizontally) by finger pressure. Evaporator & P.127 - LGE Internal Use Only .B. Motor Conductor Power Conductor Sensor Conductor Step Motor Conductor Earth Conductor Copyright ©2007 LG Electronics. All right reserved. To remove the Grille from the Chassis. Only for training and service purposes .C.Disassembly of the parts Disassembly of the parts (Indoor unit) Indoor unit 1. Split Type Indoor unit CAUTION: Disconnect the unit from power supply before making any checks. • Remove securing screws. • Lift up the right side of the cross-flow fan and the fan motor. separate the fan motor from the cross-flow fan. Only for training and service purposes . 3) To remove the Discharge Grille.Disassembly of the parts 2) To remove the Control Box.128 - LGE Internal Use Only . • Remove screws securing the evaporator and the holder eva. 5) To remove the Cross-Flow Fan • Loosen the screw securing the cross-flow fan to the fan motor (do not remove). Copyright ©2007 LG Electronics. • Remove the left end of the cross-flow fan from the self-aligning bearing. • Pull the discharge grille out from the chassis carefully. slightly pull the evaporator toward you until the tab is clear of the slot. Inc. 4) To remove the Evaporator. • Pull the control box out from the chassis carefully. All right reserved. • Unhook the tab on the right inside of the chassis at the same time. Panel Front Connector 2. . 1. Step Motor Connectors Sensor Connector 4Way/Fan Connector Comp Connector Power Connector Power Connector Comp Connector Motor Connector Copyright ©2007 LG Electronics.Remove securing screws. To remove the Grille from the Chassis. . All right reserved.After pull down this panel a bit. . . be sure to disconnect the wires from PWB. . Be sure the power switch is set to “OFF”. .Pull the cover control out from the control box and disconnect other wires. Only for training and service purposes .Lift the both lower parts of panel front. separate connecting wire with product.Before removing the control box.Pull the control box out from the chassis carefully. .129 - LGE Internal Use Only .Disassembly of the parts 2. To remove the Control Box. Inc. Art Cool Type Indoor Unit CAUTION: Disconnect the unit from power supply before making any checks. the remove 2 securing screws.Pull the grille bottom. Bracket Turbo Fan Bolt Motor Mount Copyright ©2007 LG Electronics.Remove the securing bolt from the motor shaft. . . .130 - LGE Internal Use Only . 4) Before removing the Turbo Fan. . Inc.Pull the fan out from the motor shaft. .Remove 4 screws securing motor mount from the chassis and lift up the motor mount and the bracket. All right reserved. top cover and the air guide.Remove 4 screws securing the evaporator.Pull the pipe cover. . .Remove the securing screws from the chassis. Only for training and service purposes . Top Cover Air Guide Pipe Cover 5) To remove the Motor.Pull the evaporator out from the chassis carefully.Disassembly of the parts 3) To remove the Evaporator. • Hold up Inlet Grille Horizentally. Art Cool Deluxe Type Indoor Unit(SZ. Be sure the power switch is set to “OFF”.Disassembly of the parts 3.131 - LGE Internal Use Only .S3) CAUTION: Disconnect the unit from power supply before making any checks. • To seperate connecter assembly and than to remove Inlet Grille assembly. • To remove the Grille. To remove the Grille from the Chassis. Only for training and service purposes . 1) Before removing the control box. Copyright ©2007 LG Electronics. be sure to take out the wire screwed at the other end.SU. All right reserved. Inc. pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward. Inc.Disassembly of the parts 4. To remove the Grille from the Chassis. be sure to take out the wire screwed at the other end. 1) Before removing the control box. Earth Conductor Copyright ©2007 LG Electronics. • To remove the Grille. • To seperate connecter assembly and than to remove Inlet Grille assembly. pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward. Only for training and service purposes .132 - LGE Internal Use Only . Be sure the power switch is set to “OFF”. All right reserved. Art Cool Deluxe Type Indoor Unit(SE) CAUTION: Disconnect the unit from power supply before making any checks. • Hold up Inlet Grille Horizentally. All right reserved.133 - LGE Internal Use Only . • Remove 3 screws securing the evaporator(at the left 2EA in the Eva Holder. • Pull the control box out from the chassis carefully. at the right 1EA). Only for training and service purposes . 4) To remove the Evaporator. Copyright ©2007 LG Electronics. Inc.Disassembly of the parts 2) To remove the Control Box. • Unhook the discharge grille and pull the discharge grille out from the chassis carefully. • Remove securing screws. 3) To remove the Discharge Grille. 5) To remove the Motor Cover • Remove 2 securing screw. separate the fan motor from the cross-flow fan. Copyright ©2007 LG Electronics. Only for training and service purposes .134 - LGE Internal Use Only . • Remove the left end of the cross-flow fan from the self-aligning bearing. slightly pull the evaporator toward you until the tab is clear of the slot.Disassembly of the parts • Unhook the tab on the right inside of the chassis at the same time. Motor cover 6) To remove the Cross-Flow Fan • Loosen the screw securing the cross-flow fan to the fan motor (do not remove). • Pull the motor cover out from the chassis carefully. • Lift up the right side of the cross-flow fan and the fan motor. Inc. All right reserved. • Pull the inlet grille slightly toward you.135 - LGE Internal Use Only . Remove the lower air guide • Remove a screw of both side fixing "barrier airguide". • Remove the screws of both sides of the lower air-guide.VB chassis Warning : Disconnect the unit from power supply before making any checks. Remove the air filter.Disassembly of the parts 3. Only for training and service purposes . • Pick out the inlet grille. • Unhook the hanger from the hanger screw at the left and the right side. 1. Inc. Barrier Air guide Lower Air guide R Copyright ©2007 LG Electronics. CVT Type . (2 pieces) R Inlet Grille 2. • Remove the lower air-guide toward “arrow mark” by turning upwards as shown in figure. • Pull out the air filter. Remove the girlle from chassis • Remove the screws securing the side plate and push to the bottom-side. All right reserved. Be sure the power switch is set to “OFF”. R 1 4 Hanger Hanger Screw 2 3 3. Be sure the power switch is set to “OFF”. • Remove the securing screws. Copyright ©2007 LG Electronics. All right reserved. • To remove the Grille. • Set the up-and-down air discharge louver to open position (horizontally) by finger pressure. pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward. 1. Before removing the control box. Only for training and service purposes .Disassembly of the parts VE chassis Warning : Disconnect the unit from power supply before making any checks. Inc. To remove the Grille from the Chassis.136 - LGE Internal Use Only . be sure to take out the wire screwed at the other end. Inc. 3. • Remove securing screws.Disassembly of the parts 2. do not damage the Caution label. To remove the Evaporator.137 - LGE Internal Use Only . Caution label When repair. • Pull the control box out from the chassis carefully. All right reserved. Copyright ©2007 LG Electronics. 4. at the right 1EA). • Unhook the discharge grille and pull the discharge grille out from the chassis carefully. To remove the Control Box. To remove the Discharge Grille. Only for training and service purposes . • Remove 3 screws securing the evaporator(at the left 2EA in the Eva Holder. Only for training and service purposes . 5. • Remove the left end of the cross-flow fan from the self-aligning bearing. Inc. 6.Disassembly of the parts • Unhook the tab on the right inside of the chassis at the same time. • Lift up the right side of the cross-flow fan and the fan motor. To remove the Cross-Flow Fan • Loosen the screw securing the cross-flow fan to the fan motor (do not remove). slightly pull the evaporator toward you until the tab is clear of the slot.138 - LGE Internal Use Only . Copyright ©2007 LG Electronics. separate the fan motor from the cross-flow fan. • Pull the motor cover out from the chassis carefully. To remove the Motor Cover • Remove 2 securing screw. All right reserved. (do not remove) • Remove the crossflow fan by sliding it out from the shaft of fan motor. • Disconnect the step motor connector. All right reserved. disconnect power supply cord and connecting cable from the terminal block and remove the cord clamp screw. Only for training and service purposes .Disassembly of the parts 4. Remove air guide upper. Motor Cover Bearing Cover R Bearing 5. Remove the control box Assembly. • Remove 2 screws securing the control box and pick out the control box carefully.139 - LGE Internal Use Only . fan motor connector. • Remove 4 screws securing the motor cover. thermistor connector and door switch connector from the main PCB. • Loosen the screw securing the crossflow fan to the fan motor shaft. • If necessary. Inc. R Copyright ©2007 LG Electronics. • Remove 2 screws fastening the bracket of door switch. crossflow fan and motor. Door Switch R • Remove a bearing assembly by removing a screw and the bearing cover. • Remove the screws of both sides and center securing the upper air-guide. display PCB connector. All right reserved. (4 pieces) • Push the upper side of cabinet strongly to pull out the inner hook of diffuser frame from the cabinet hole. • Pull down the front panel carefully not so as to harm the display PCB wires and thermistor wires. • If necessary. Diffuser frame Hook Cabinet R 8. Display Cover Copyright ©2007 LG Electronics. • Remove the screws at the both side of display cover. disconnect the display PCB connector from PCB assembly. Remove the front panel. • Remove the screws of both sides fixing the front panel.Disassembly of the parts 6. • Take up the diffuser frame carefully not so as to harm the display PCB wires and the step motor wires. Inc. Diffuser frame Diffuser frame Hook Front Panel Front Panel R 7. Remove display PCB assembly. • Remove the screws of both side of diffuser assembly. • Remove 2 screws of PCB assembly.140 - LGE Internal Use Only . Remove the diffuser assembly. • Push the upper side of front panel strongly to pull out the front panel from the inner hook of diffuser frame. Only for training and service purposes . Barrier-R Copyright ©2007 LG Electronics. Inc.Disassembly of the parts 9. All right reserved. • Remove the screws of both sides securing the EVA barrier-R/L on the side cabinet. vane-lower and step motor. (As shown in figure) EVA. Remove the drain pan assembly. • Remove the screws which fasten the barrier on the evaporator and take out the barrier assembly. • Remove the both side of screws. • Remove 2 screws securing the step motor assembly and pull it out from the vanes carefully. • Remove the evaporator assembly by sliding toward arrow mark. Step Motor Vane Supporter Lower Vane Upper Vane 10. • Unhook the vanes from the vane supporter and remove the upper vane and lower vane by pulling the center of vanes with care. Remove the vane-upper. 11. Only for training and service purposes . (4 pieces) • Pull out the drain pan assembly. Barrier-L Side Cabinet EVA.141 - LGE Internal Use Only . Remove the evaporator. • Be careful not to harm to the EPS packing of drain pan and the tubings of evaporator. 00MTW XOUT VSS A15 R26 34 A16 R27 33 5V IC01K(TLP621) R01L.10K R02F.1K REMOCON D01K 1SR139-600 RX C01L 680pF 50V TX C01K 0.8K Q13G KTA1270Y DISPLAY DC 5V 1 1 7 7 GND REMOCON 2 RD Wt R/W C R30 64 R31 63 C02F.1M Q01M KRC107M Electronic Control Device 31 32 R02L.10K R03T.1K 2 3 4 MICOM GMS81516 5V R02H 12.220 4 ROOM-TH 4 R04 52 R05 51 R06 50 D7 A0 R52/Sclk R51/Sout R50/Sin R47/T30 22 R46/T10 23 24 TX RX 6 7 11 10 4 R04G.AC275V 1 1 FAN MOTOR IC02D O 7805 C05D 470uF 16V I D02K 1SR139-600 3 3 COM Schematic Diagram C01J 0.10K R05T.0..120.8K Q11G KRA1270Y 5 3 3 LED2 PRE AMP ASSY TFMS2380B C02L 6 6 2 2 LED1 7 7 1 1 CN-DISP1 220uF IC02M CN-TH PIPE-TH 10V 8 9 10 R03H.01 50V RESET' 30 BZ01E R01E.1/2W C01M. AC275V NF01J FUSE 250V/T2A FREQUENCY 2 2 LIVE 1.220 3 R03 53 D4 D5 D6 R54/WDTO 17 R53/Srdy 18 19 20 21 5 12 3 R02G.6.1K R01K 10K DC 3 2 5V 4 IC02K(TLP627) 2 1 R03K 1K ZNR01K 14D271 NF01M ZNR01M INR14D471K CN-FAN 3 NF01M 3 3 R02C. All right reserved.1K R64/AN4 R63/AN3 R62/AN2 11 HALT R37 57 D0 D1 R61/AN1 12 KID65004AP CN-DISP2 R06G.10K SLIDE S/W REMO 1 R03F.1K 12.220 0.7K M C02C 0.8K R11G.220 2 4 13 2 R07G.1K 12.220 1 2 3 R01H.10K OSC01B CST-8.01 50V 5 R12G.8K Q12G 3 5 5 LED4 Vcc 2 3 4 5 6 7 4 R32 62 R33 61 SYNC R34 60 BRK R35 59 BRQ R36 58 KTA1270Y 4 4 4 LED3 0.142 - 3 3 LGE Internal Use Only .1K 1 4 SSR-MOTOR 2 2 INDOOR 5V R04C.220 5 5 R05G.1K A12 R23 37 5V 29 R03A.1K IC01A C02A 10uF/50V + A13 R24 36 XIN R01B.4.1% R01M.10K R02T.2K 12.6.7K R01C.7K R01A.01/50V C01F.1K R01F.6.015 50V Q01C KTC3198Y C01C 0.20 R02A. Inc.6.0.1.01 25V + Q01K KRC102M R04K 680 R05K 25K.1 50V D01D 1SR139-600 D02D-05D 1SR139-600 ZNR01J INR14D471K SVC561D-14A 1 1 NEUTRAL CN-POWER C01D 2200uF 35V POWER TRANS 6171AQ3124C Copyright ©2007 LG Electronics.1K 12.20K R05C 4.01 25V + O C03D 470uF 25V 7812 I + C02D 0.001 25V R02K.4.220 7 S 1 C 2 R11 47 R12 46 R13 45 R14 44 R15 43 A6 A7 R43/INT3 R42/INT2 R41/INT1 R40/INT0 28 7 8 VCC 7 DU R01T.1K 12.1.1K R04H R16H R15H R14H R13H R12H R11H R16G.100 KIA7036P C01A 0.10K DC 5V 2 2 4 4 5 R16 42 R17 41 A8 R20 40 A10 R21 39 A11 R22 38 DC 12V 5 6 6 7 7 IC01M 8 8 Schematic Diagram KID65084AP 9 SSR-MOTOR 9 CN-SUB R02E.01/50V R14G.6.6.1K 1 2 3 4 C01H C02H R00 56 R01 55 D2 R60/AN0 13 14 15 1 2 16 15 1 R02 54 D3 R57/PWM1 R56/PWM0 R55/BUZ 16 3 14 1 R01G.3W.8K R15G.10K RD 1 1 DC 12V OR 2 3 4 5 15 4 3 2 1 16 17 18 5 14 5 4 13 6 3 12 7 2 11 8 DC12V 10 OP6 XXXK OP5 XXXK OP4 XXXK OP3 XXXK OP2 XXXK OP1 XXXK 9 DC 5V 8 8 DC 5V YL PK BL STEP MOTOR UP/DOWN DC 12V 1 D 3 Q 4 6 ORG 5 Vss 1 R04T.5V R04F. Only for training and service purposes A14 R25 35 .1K 1% 1% 6.8K 2 6 6 Vout 1 C01M Vdd MP AVss AVref R67/AN7 R66/AN6 R65/AN5 3 R13G.01 50V CN-U/D 6 EEPROM R07 49 R10 48 A1 A2 A3 A4 A5 R45/EC2 R44/EC0 25 26 27 8 9 6 R03G.10K FREQUENCY R03C.0.01 25V DC 5V C06D 0.1K 12. Indoor Unit 1) Split Type IC01D DC 12V C04D 0. Only for training and service purposes .Schematic Diagram 2) Art Cool Type Copyright ©2007 LG Electronics. Inc. All right reserved.143 - LGE Internal Use Only . Only for training and service purposes .144 - LGE Internal Use Only .Schematic Diagram 3) Art Cool Deluxe Type • A/C MOTOR Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes . Inc. All right reserved.Schematic Diagram 3) Art Cool Deluxe Type • BLDC MOTOR Copyright ©2007 LG Electronics.145 - LGE Internal Use Only . 1K 1% 5V 12V 5V R01K 1 3 RY-LOUV 3 1 STEP M4 STEP M R08H 12.3A ZNR01J INR14D561K NF01J 22mH/3A R01J D01D 1M.00MHZ (INT3/TC3)/P50 (SO2)/P47 (SI2)/P46 43 42 41 25 26 LED1 XOUT VSS (SCK2)/P45 (SO1)/P44 CC RX CC TX Multi_RX 6 중앙_RX 중앙_TX 유선_RX GND 5V 6 1 2 1 2 Multi_RX Vcc 3 R04L 1K GND 5V PRE AMP TFMS-2380B LED3 LED2 4 R05L 1K 5 6 7 40 39 27 CN-DISP 유선_TX 12V 3 SO1/PLC P30 LED2 (SI1)/P43 3 4 4 12V SO1 Force SW LED4 R06L 1K 38 28 5V SI1/MULTI TX P31 LED3 (SCK)/P42 SCK1/MULTI RX 5 5 SI1 37 29 P32 NC 6 6 SCK1 36 R02F R01F 7 LED4 1K 1K 7 CS0 CN-LOUVER 1 3 3 1 30 LOUVER FLOAT P33 NC 35 31 32 P34 P35 C02F 103 C01F 103 8 NC NC 8 CS1 Schematic Diagram 34 33 CSO CN_ZONE CN-FLOAT 1 2 1 2 CSI Copyright ©2007 LG Electronics.6V C01A C02A 102 6 ORG 47 S_B3 4) Duct Type .1K 1% R06H 12.7K ROOM TH OPTION 1 1 50/60Hz MOTOR 3 PHASE EERROM 1 S CN-ROOM CN_M C AC_N R02C 1K R01C 200K/2W Q01C R05C 1K C01C 103 R02A 10K 5V 1 R01E 1K 5V VCC 7 DU C 8 16 17 C P15(TC2) P16 VARF VASS 49 48 18 P17 P54 SB3 5V 12V KIA7036P + 2 3 R01A 1K GND C01U 103 OR6 OR5 OR4 OR3 OR2 D 1 OR1 C02H C01H 103 103 5V 1 2 2 12V 5V 3.0M P22(XTOUT) RESET XIN XOUT OSC01B 8.1K 1% R03H 12.7 S/Trans IC03D KID78L05BP I O 7805 C09D 220uF/50V IC11K(TLP621) R11K 10K C11K 102 M_RTX R13K 1.5 IC02D(TLP521) EN BP R03D 150 ZD02D 11V C04D 103/250VA C07D 330uF/35V 470uF/35V 2 D03D UF5402 3.2K R01H 1% 12. Only for training and service purposes IC01A 3.15A.1K 1% R02H 6. All right reserved.1K DC 5V M_RTX D12K 1SR139-400 D11K 1SR139-400 DC 5V 1 AC_N C01D 10uF/ 400V IC01D TNY255P S 3.1K 1% R05H 12.146 - LGE Internal Use Only .1K 1% 1K 유선_RX C03K 102 D02K CN-MOTOR1 1 2 FAN RY-L 3 RY-M 4 RY-H CN-MOTOR2 SSR NF01M NF01M 1 2 LOW IC01M KID65004AF OPTION6 OPTION5 OPTION4 OPTION3 3 3 C01K 102 C02K 102 Q04K DAN212K KRA104M 壤 DC 12V MOTOR 3 4 REMO 50/60Hz CN-PIPE 3 3 Q02K KRC104M REMO C02L 681 OPTION2 PIPE TH 1 1 FREQ 5V 5V R03C 10K AC_L 1 R06C 10K 1 FAN 2 ZNR01M 1 2 3 IC01C BZ01E R02E 20 R04C 4.5K RX 2 1 3 4 Multi_RX R12K.3uH G C08D 104 R04D LIVE 1 2 250V/ T3.8 CN-OUT RY-OUTFAN 1 RY-4WAY 3 3 RY-4WAY 1 RY-OUTFAN 1 NEUTRAL 3 4 39 R16K 10K 3 4 R15K 82K/3W 3 3 M_RTX RY-COMP SIGNAL C03J 10nF 275V C01J 100nF 275V D02D UF4005 D 5 4 TNY 255P 2 1 C03D 103 C02J 100nF 275V 2 1 IC12K(TLP627) R14K 1K TX Multi_TX DC 5V Q11K KRC104M AC_L DC 12V DC 12V STEP M RY-HEATER IC02M KID65004AF IC02M KID65004AF L01K D01K DAN212K 100nH 5V 12V DC 12V CN-REMO 유선_TX STEP M5 RY-HEATER 5 5 1 P76 P77 P00 P73 P72 P71 P70 VDD (AIN7)/P67 (AIN6)/P66 (AIN5)/P65 (AIN4)/P64 (AIN3)/P63 (AIN2)/P62 (AIN1)/P61 P14(PPG) (AIN0)/P60 P01 P02 P03 P04 P05 P06 P07 P10(INT0) P11(INT1) P12(INT2/TC1) P13(DVO) P74 P75 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 5V HEATER 4WAY Q01K Q03K KRC104M R02K L03K 3 MED 4.3uF /50V 5V 5 VSS Q 4 S GND 19 20 NC P20(INT5/STOP) TEST P53 (PWM/PDO)/P52 46 45 21 P21(XTIN) (INT4/TC4)/P51 SB2 SB1 S_B2 5V R01U 10K S_B1 GND 3 C02U 103 3 4 SB0 Multi_TX GND 4 5 5 PLC_SEL Multi_TX DISPLAY GND 1 2 LED1 1 2 3 4 5 6 7 5V R01L 10K R02L 1K 44 REMO S_B0 Vout NC RESET XIN R01B R03L 1K 22 23 24 1. Inc.1K 1% R04H 12.7K 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q D 2 3 2 1 DC12V 3 Signal 2 GND 1 CN-D/PUMP Drain Motor D/PUMP OUTFAN A/C COMP 1 1 L02K KRA104M STEP M RY-D/PUMP STEP M2 STEP M3 LOUVER HIGH C05K C04K C06K 104 103 3 3 CN-LOUVER Louver Motor STEP M R07H 12.7.1/2W 1N4007 12V L01D 1 6.DC310V C05D 681 CN-POWER 2 5V C10D 103 C11D 223/1KV C12D 103/1KV NF NTC01D 10D-9 ZD01D P6KE200A C06D 3 4. Schematic Diagram SLIM DUCT(B1. Inc. All right reserved. Only for training and service purposes .B2) Copyright ©2007 LG Electronics.147 - LGE Internal Use Only . 1K R04F.2K 12.2K 1% R01H R02H 6. 1% R22H 12.1K 1% 1% 6 OR4H 1 C02G 103 C01G 103 PIPE-OUT_TH RD 1 1 CN-TH1 4 3 2 4 3 2 1 1 OR6H STEPPING MOTOR (UP/DOWN) 12V 1K R04H 1K R05H 1K R06H 5V C03H C02H C01H 4WAY INDOOR FAN 3 44 P67/A7 47 P72/A10 48 P73/A11 PA7/AN7 R01P 10K 8 100nH L01K D03K DAN212K CN-U/D1 BL 5 4 3 2 2 IC02M 5) Convertible Type 5 4 3 1 2 PA5/AN5 PA6/AN6 3 4 5 1 2 12V 5V 4.7K R07D 12K Q01C KTC3198-Y 2SC5343 CN-DOOR C02L 4.1K R12G PA0/AN0 62 5V 12.7.330.45.26.1K PRE AMP ASSY TFMS2380B 30 29 28 27 C03F 3 4 5V C04F LED1 7 + 4 R06T.1K.2K R09K PIPE-TH PK 49 P74/A12 103 103 103 YL 12V 9 8 OR 19 18 SDA SCL MODE/WC 7 6 5 EEPROM IC 1 C11K 104 Q01K KRA104M Q03K KRC104M C12K 103 RD 1 1 R02E.330.31.10K 5V COMP IC04D S78DL05L 1W C03D 681 SMPS D07D UG2D + RY-4WAY RY-COMP T1 FAN 4WAY INDOOR FAN INT FAN 4WAY COMP D/PUMP 1K/1W INDOOR FAN TR01J SM1L43 RY-D/PUMP CN-MOTOR 3 3 T2 Copyright ©2007 LG Electronics. 1% R21H 9 8 7 MICOM 20K R14G 40K R15G 4 3 4 37 P60/AO 38 P61/A1 39 P62/A2 12.20 3 4 12V R01E 1K BZ01E PKM13EPY-4002 SBT1/P05 SBI1/P04 20 BUZZER/P06 SBO1/P03 17 R01F.148 6 Option CN-HVB 3 2 1 1 2 3 HVB SEL 3 2 1 JP1 JP3 3 2 4WAY 2 1 HVB OUT CN-CONT 1 INDOOR FAN INT JP4 JP2 JP5 JP6 COMP 5V 12V Tx FAN Rx D/PUMP 3 2 1 3 2 1 CN-12V 2 1 12V DC PART 7 8 9 10 CN-ACDC 1 2 3 4 5 6 CN-ACDC 1 2 3 4 5 6 7 8 9 10 D/PUMP 12V RY-FAN IC01J TLP762JF 12V 1 2 3 R03J 680 1/2W 6 NF02J AC PART FOR NORMAL 12V R04J 560 1/4W 3216 4 ZNR02J TVR10561 INDOOR FAN MOTOR SH-CAPACITOR NF02J D05D 1N4007 NTC SCK-102 R02J 100.1K CN-REMO L03K 3 2 1 L02K 3 2 1 CN_INSTALL 1 3 1 3 DISPLAY 7 P54 36 Force C01F 103 GND 1 2 RECEIVER R04G.10K R04T.1K R06G Schematic Diagram COMP FAN 5 4 R03H 6.8 D08D LL4148 R06D 300K 1/4W 3216 NF01J 15mH/1A 3 4 RY-4WAY G5N-1A(G5NB-1A) 4 4 FUSE 250V/T2A 4 3 FAN MOTOR 4-WAY 2 1 2 1 RY-COMP G4A-1A-E-LG 4 2(N) 1 COMPRESSOR DC HIGH VOLTAGE GND 3 ZNR01J TVR10561 C02J METAL FILM 47nM/275V/435D C01J METAL FILM 100nM/275V/436D 1(L) L 1 CN-TAB1 1 N CN-POWER AC220~240V 50/60Hz LGE Internal Use Only .4.46 54~56 2 8 9 1M R01B 5V OSC01B 2 C02F.1K 1 2 3 R06F. 1/2W 3 4 RY-D/PUMP G5N-1A(G5NB-1A) 1 3 C03J 100nF 275V/436D RY-FAN G5N-1A(G5NB-1A) T-BLOCK 1 3 Drain Motor CN-D/PUMP OUTDOOR + C09D 220 10V SD C08D 103 50V R02D 20K 1 2 ZD02D BZX55C11 DC LOW VOLTAGE GND 4 3 D 5 IC02D TLP181(V4 BL) EN 4 BP 1 C05D 472M DC HIGH VOLTAGE GND C02D 104 INT 3 4 5 5 C01D 15uF 450V/SG 4 1 2 3 IC03D TLP181(V4 BL) DC HIGH VOLTAGE GND DC LOW VOLTAGE GND IC01D TNY266P S 2.6V 2 Tx 5V R02L.1K.1/2W 12V 5V 7805 O I L1 ZBF503D 2 1 2 1 5V C04D 470/35V/SD SD01D STO2D-200 + R04D 27k 1/8W 2012 R05D 300K 1/4W 3216 C07D 104 50V C06D 330 25V SD R03D 39 1/8W 2012 BD01D DF08M R01J 120.10K R02T.3.10K 2 2 3 3 5V 1 1 6 7 8 9 Vdd Vref+ 7 8 9 7 . Inc.1/4W R03G. 1% R23H 80K R13G 2 PA1/AN1 PA2/AN2 5V 63 64 SW-LOW WH YL OR BL BR RD 2 1 1 2 STEPPING MOTOR CN-U/D2 BL 5 5 R11G 1K 3 A B C 4 5 3 E F 0 1 6 2 D 5 10K R10G 6 9 8 7 4 (UP/DOWN) 40 P63/A3 12V IC01M 9 8 61 Vref1 2 CN-TH2 5V 2 1 1 ROOM-TH R05G 1K 80K R07G 2 OR1H F1 20K R08G 40K R09G OR2H F2 OR3H F3 PK 4 3 2 2 3 4 YL OR D/PUMP 3 2 3 7 PA3/AN3 PA4/AN4 41 P64/A4 42 P65/A5 43 P66/A6 OR5H 12.7 50V Rx INT R08D 56K CN-CC DC 5V DC 12V DC 5V R01A 1K 1 3 3.330.103 CN-FLOAT R03F. All right reserved.330.1K R01L 5.1K C01L 680pF/50V 1 2 3 C01A 10/ R03A 100 1 2 3 4 32 P50/NWE 50V 1 2 3 4 5 33 P51/NRE OSC1 OSC2 NRST/P27 5V 53 receiver 3 3 1 21 IC01A 1 4 5 6 34 P52/NCS 35 P53/A16 22 P10/TMOIO 23 P11/TM1IO Vss 10 XI 11 MMOD C01Z 103 Telecontrol 5 6 7 8 9 NU 13 12.1/4W 1 2 3 4 5 6 R01G.10K R01T. Only for training and service purposes 7 DC 5V IC03M 12V 9 8 8 FORCE 8 16 P02/SBT0 15 P01/SBI0 14 P00/SBO0 D7/P87 R02A.1/4W 6 50 P75/A13 51 P76/A14 R02F 10K 5V R08K 1K 12V C10K 102 Vout HVB OUT 4 5 52 P77/A15 TM3IO/P13 C08K 102 5V Q02K KRC104M D02K DAN212K Vcc LED4 3 4 5 6 1 2 3 25 24 C09K 102 Q04K KRA104M 57 P83/D3 58 P82/D2 59 P81/D1 60 P80/D0 SEL LED3 LED2 TM2IO/P12 IRQ3/P23 IRQ2/P22 IRQ1/P21 IRQ0/P20 R07F R05F 1K 1K 5V 1 2 R08F.1 LEV CN-LEV 2 DC12V SW-HIGH 6 6 3 5 3 A 5 4 5 3 E F 0 1 6 2 B C D 1 10K R16G 6 4 5 4 3 MN101C30A QFP64 12.10K R03T.10K R05T.1K.1/4W R02G. All right reserved.7K DELET KRA102S C11K 103 VAREF 17 16 Q04K P07(INT2) H/S1 OR1 OR2 C21D 104 OR4 OR5 C03H C02H C01H 103 103 103 1 2 3 4 5 6 7 8 9 1N4148 DAN212K XOUT XIN TEST VSS VDD RESET (RxD1)p01 (SO1)P05 (SCK1)P06 (XTIN)P21 (INT0)P00 (TxD1)P02 (INT1)P03 (SI1)P04 (XTOUT)P22 Q02K KRC102S 12V (STOP/INT5)P20 BMS ON/OFF SUB_PCB Hotel card key pad SUB_PCB D02J 1N4148 5V SW1 YFW254-03 R02B 10K*6 R01T R06T R03T R04T R05T 12V 5V 1 1 12V Q02K KRC104S 2 2 5V RY02J G5NB-1A 12V 3 3 R02A 10K 5V 1 3 R03A 200 3 G/C H/S2 2 R01A 1K KIA7036P IC01A 3.1K HVB_S R03E.R05H.8V 10K C12D 100UF 25V 4.7K 1% 2 3 R09D 1K 1 4 PWM R01C 1K (2012) BZ01C PKM13EPP-4002 4.01uF 400V 3 3 ZNR01J INR14D561K 2 2 S1 1 1 1 3 P60(AIN0) R06B 10K AD_CH0 AD_CH0 ROOM_TH 1 AD_CH1 AD_CH1 PIPE_TH1 3 3 1 3 P64(AIN04/STOP0) AD_CH4 AD_CH4 CN-PIPE2 CN-PIPE1 CN-ROOM SMW-250-03P Copyright ©2007 LG Electronics.15A (DIP) FUSE ZNR01N SVC561D-14A N/F01N 11mH/1.33UF 275VAC (DIP) R018D 1M 1/2W AC(N) BD01D (DIP) D3SBA60 CY6 332M DC310G SMW-200-10P ΩÂ˚-±◊¸± SUB PCB 4 5 3 4 D02Y 22uF/35V SS14 CN_A5 +15V 1 C05Y U02Y 8 1 1 +5V TX 2 R01Y 7 C07Y 104 104 3 6N137 RD 1 1 DC 311V C11D 473 630V (TM) 4 1 IC05D TLP181-BL 4 5V 5V D06D 1N4148 4 4.7K C16K 103 3 GT-250-3P-TS C15K 103 C14K 104 R15K AVDD +5V 1 P36 2.6V 2 CC_RX Áß Ó_RX 5 5 5V CC_SB3 CC_SB2 COMP Q01K KRC104S 6 6 C01A 105 C02A 103 +5V 3 2 3 2 C20D 104 C15M 103 CS3 CS2 CS1 R16M 1K CC_RX CC_TX 1 CC_SB1 OR3 R06H 12.2K DELET D12K C13K 102 63 A7 P37 18 64 11 10 12 13 14 15 R16K 4.62K 6 5 R02Y 5.1W(DIP) C19D 103.R08H 12.2W SMPS(6170A90026A) D01D UG2D L2 12uH(DIP) SMW-250-6P +15V 12V + C05D 220uF 35V 13 14 15 16 4 3 2 1 SM12 SM12 SM11 SM10 5V A6 8 9 10 A1 A0 GND A1 A0 R07M 10K CN-GRIL_RIGHT NF02J FP_R_UP A7 R08M 10K CS1 R09M 10K FRONT PANNEL UP_DOWN Motor 1 3 2 1 3 2 FP_R_DOWN TRB R10H 1K CS2 Q01H KRA104M C07H 103 R09H 10K R01H~R04H 10K*4 R05H~R06H 1K*4 Q01D KRC104S D08D 1N4937 D03D UG2D S78DL05L.2K 1% 1% 1% R04H.2K 6.7K R03Y 1 U03Y 8 1 8 2 2 3 4 5 6 4 1 5 R08D 1K on/off 5 SEL 2 R07Y 6N137 7 C08Y 104 2 7 2 2 BUS(B) IN DOOR FAN WH 5 6 7 7 R12D R10D D07D 1N4148 BL YL D05D 1N4148 3 2 3 BK 4 KRA223S Q05G D04D 1N4148 3 2 CS6 HVB_S R09H~R14H 12.630V L1 12uH(DIP) 7805 + C06D 470uF 25V R07D 1K 1/4W C07D 220uF 25V C08D 104 50V C04D 104 50V C03D 220uF 10V + + IC04D C02D 470uF 35V + R06D 1K 1/2W C09M C08M C07M C06M 103 103 103 103 IC03M KID650004AF CS2 R10M 10K 5V CS5 +5V CS3 R11M 10K C08H 103 C03H~C06H 103*4 1 20 SM43 B0 1 CS4 CN_GRILL 20 A7 A7 R12M 10K 5V R19D 5.1K CN-FLOAT C03F 103 R01F EERROM M24C01-BN6 WC IC06D TLP181-BL C06Y 104 IN DOOR FAN WH 5 5 BL 6 6 BK 4 4 3 3 GT-250-3P-TS 5V AD_CH13 R04F AD_CH13 C D Q S 10K AD_CH12 R01G MOTOR R13D 1K C11H 103 C12H 103 R30H 10K R29H 10K C15D 103 CN-M OT OR2(BL) 2 3 H/S2 P77(AIN17) P76(AIN16) P12(PPG) P11(DVO) P44(SI2) 3 2 1 C02G 103 P45(SO2) P10(TC1) 1K P41(RxD2) P42(TxD2) 7 7 P75(AIN15) P46(SCK2) YL 10K R02G OFF_ON AD_CH11 AD_CH10 P47 P43 PWM SMW-250-07P P40 AD_CH9 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 DISPLAY GND 1 R02L 1K 1 2 3 LED1 LED2 LED3 LED4 R01L 10K YFW254-03 (INT3/TC2)P15 CS4 CS5 33 +5V SW2 AD_CH8 Vout 2 R07L 330.1K*6 1% 3 6 LED1 0.149 S 2WAY SUB M OT OR CN-M OT OR1 (WH) SMW-250-07P Q04G KRA223S 4 3 3 U01Y SN65LBC176 L02Y 12uH YW-396-02V CN-COMM 2 2 0.1/6W LED1 49 (PDO5/PWM5/TC5)P16 (PDO6/PWM6/PPG6/TC6)P17 (SCL)P50 LED1 32 50 51 52 (SDA)P51 LED2 P74(AIN14) AD_CH12 OR6 OR7 OR8 OR9 OR10 OR11 R03L 1K Vcc 3 R04L 1K C02L 681 31 P73(AIN13) AD_CH11 PRE AMP TFMS-2380B LED3 LED2 4 R05L 1K 4 5 6 7 CN-DISP +5V 30 29 53 P52 LED3 5 6 7 P71(AIN11) AD_CH9 +5V 8 8 OR4 9 9 OR2 Force SW LED4 R06L 1K 28 54 P53 LED4 P70(AIN10) AD_CH8 10 10 OR1 27 55 WR_RX 5V WR_TX P67(AIN07/STOP3) AD_CH7 AD_CH7 11 11 SMW-200-7P L01K 100nH 26 P54 P66(AIN06/STOP2) AD_CH6 AD_CH6 56 A0 C18K 103 25 P30 P65(AIN05/STOP1) G/C 57 A1 A2 WR_RX 24 P31 P32 3 CN-REMO 12V 58 59 A3 C17K 102 Q01K KRA102S DC12V 3 Signal 2 GND 1 3 2 1 R12K 20 Q03K KRC102S MICOM P33 23 22 60 A4 A5 P34 P35 P63(AIN03) P62(AIN02) R04B 10K AD_CH3 AD_CH2 AD_CH3 AD_CH2 PIPE_TH2 1 21 61 62 12V R11K 5V P61(AIN01) R05B 10K 1 20 19 A6 C12K 102 4.7K TLP181-BL P14(TC4/PDO4/PWM4/PPG4) WR_TX 5 SDA SCL IC07D 1K OUT_RX OUT_TX C06F 103 R11D 5.3A B2 16 6 7 8 9 GND 10 15 14 13 12 11 B3 B4 B5 B6 B7 R02H 1K NF01J 22mH/3A AC(N) IC3 KID65004 12V OUTFAN D/PUMP SMW-250-04P CN_HVB 4 5 6 7 13 RY-HEATER1 12 RY-HEATER2 13 CN-D/PUMP 35328-0210-NA(molex) 11 RY-HEATER3 14 15 16 9 IC01K(TLP181-BL) R03K.1K*5 1% 1 ZD01D 6.2W R20D 110K.1K 6.1K C01K 102 10 RY-HEATER4 CS1 Drain Motor 1 3 3 RY-D/PUMP 1 20 B0 19 IC2 OUT_RX 2 3 4 R02K C03K 1K 103 1.3W 3 D01K BZX55C68 2 1 R14K 680 OUT_TX CN-LEV A A SM11 4 IC02K(TLP181-BL) 68V/1W D02K 1SR139-600 1N4007 CHANGE Q04 KRC102S 6 12V 6 5 9 10 11 12 A A SM43 SM10 8 7 2 3 1 C01D NF C01D 1 A2 R03M 10K INR14D561K 1 2 AC(L) 1 2 2 A3 R04M 10K CN-GRIL_LEFT 3 4 SM22 18 74HC574 B1 B2 17 16 15 14 13 B7 12 11 C02M/102 2 FP_L_UP 2 3 A4 R05M 10K FRONT PANNEL UP_DOWN Motor 6 5 SM21 SM20 B3 B4 B5 B6 SM13 3 1 3 2 1 3 2 NF01J 3 4 FP_L_DOWN +5V 3 4 A5 R06M 10K 5 4 3 2 A A A A SM21 SM13 SM20 4 4 4 3 2 1 DC310V 1 R18D 200K.5K 104 1 SM23 12V 1 A1 R02M 10K ZNR01D 1 2 R10M 1M CN_LEFT_SW CN_RIGHT_SW C01J DC 5V R01K 10K WH YL OR BL BR RD 10nF 275VAC DELET (DIP) R05K 15K. Inc.33uF 275VAC (DIP) C01D 220UF 450V or 680UF NTC 400V DSC8D11M 5V ISOLATED GROUND PLANE U05Y MAX253 C01Y 104 7805 VR01Y 12V C04M 103 11 10 CS2 CS3 C03M/102 1 3 9 10 CS6 9 10 TRB CS3 GND 10 11 B7 1 8 TRANS01Y 1 6 D01Y IN GND OUT 2 7 SS14 C02Y C03Y 2 5 1/2W 3 6 104 22uF/35V C04Y 2 C03N 0.7K 2 (2012) 5V 3 U04Y 8 6N137 7 6 RX R05Y 4 5 MOTOR R02C.R07H.0K 20 B0 19 IC1 1 2 3 74HC574 12V 100uF/25V A7 A7 A6 A5 A4 A3 A0 A2 A2 A1 A1 A2 A3 GND CS1 CS4 1 A0 A7 A6 A5 4 5 6 7 A4 A3 A2 A7 A6 A5 A4 A3 A2 R01M 10K +5V SMW-200-8P CN_PTC2 C04H 12V C04H CN_PTC1 5V 1 C03H 47uF/25V 20 A0 8 C05H 5V 4 3 3 IC02M KID65004AF 4 R02E 1M C01E 104 B1 18 17 16 15 14 13 12 11 COMP A6 A5 A4 A3 2 8 C01H 5V 12V IC1 19 A1 C02H B0 3 74HC574 PTC_HE ATER SUB_PCB 18 7 104*2 AC B1 7 6 5 4 3 2 1 6 5 4 3 2 1 A3 +5V 5V COMP B2 4 5 6 7 8 9 10 C01M/102 A2 104*2 2 2 DC12V 1 B B B B B B 1 10 11 12 A/C_OUT D/PUMP OUTFAN 4WAY COMP A/C_OUT 7 SM22 6 SM23 5 4 3 2 1 8 +5V 4WAY B3 B4 B5 B6 B7 A0 A0 A1 4 A3 A0 A1 A2 17 5 A4 A5 A6 A7 R01H 10K Q01H KRA104M 250V/ T3.20 +5V R06Y 0.62K CN_OPTION SMW-200-11P 1 1 OR11 2 2 OR10 3 3 OR9 4 4 OR8 5 5 OR7 6 6 OR6 7 7 OR5 .7K IC08D TLP181-BL 1 4 R03F P13(TC3/PDO3/PWM3) H/S1 10K 6 R15D 2.0A L 1 N 2 1 2 6) CST Type DRY_CONTACT SUB_PCB CN_POWER BR-762C-2P CN-CC SMW-200-9P C02J 104 C01J 0.5A CY3~4 472M + C02N 0.6K IC01D TNY267P 1BP 2 S 6 IC02D PC-17K1 4 ZD03D BZX55C11 3 R22D 1K 1 C22D 104(DIP) DC LOW VOLTAGE GND R21D 39 ZD02D UZP-11B 5 D 4 EN R17D 470 SMW-250-10P STEPPING MOTOR »óÇÏ ÅäÃⱸ CN-UD2 C05M 103 CN-UD1 RD 10 10 12V 12V RD 10 10 9 9 8 8 7 6 5 4 3 2 1 1 7 6 6 5 4 3 2 5 4 3 2 1 BL PK YL OR RD BL PK 7 YL 8 9 9 8 7 6 5 4 3 2 1 OR OR YL 9 10 11 12 13 14 15 16 B A A A A A A A C18D 104 DC HIGH VOLTAGE GND 8 7 6 5 4 3 2 1 IC04M KID65004AF 19 SM30 SM31 SM32 SM33 SM40 SM41 SM42 IC3 2 SM42 SM41 SM40 SM33 SM32 SM31 SM30 B1 B2 B3 B4 B5 B6 B7 18 74HC574 C06H 220uF/25V C22H A0 CS5 3 17 16 15 14 13 12 4 5 6 7 8 9 A6 A5 A4 A3 A2 A1 A0 A6 A5 A4 A3 A2 A1 A0 A0 4 A1 5 A2 6 A3 7 CS1 8 GND 7 8 6 5 4 R13M 10K 12V 2 1 CS6 R14M 10K IC1 19 1 C07H 5V B0 C02H C21H C01H 12V 1 A1 2 104*2 20 3 2 3 3 5V 5V 18 74HC574 B1 A2 104*2 47uF/25V IC3 A0 4 A3 A0 A1 A2 A3 CS1 2 17 5 R14H R13H R12H R11H 1K*4 IC2 19 B2 16 A4 A5 A6 A7 GND 6 7 8 9 10 15 14 13 12 11 B3 B4 B5 B6 B7 KID65004 12V CS3 A1 A2 FP_L_UP FP_L_DOWN FP_R_UP FP_R_DOWN 3 4 A3 A4 A5 A6 CS2 18 74HC245 B0 17 5 6 7 8 A7 9 16 15 14 13 12 B1 B2 B3 B4 B5 B6 DC310V CY7 103 (DIP) PK BL RD OR YL 4 CN-POWER YW396-07 AV AC(COM) MULTI-V 485 SUB PCB 3 PK BL CN_PN YW-396-03 R017D 560K STEPPING MOTOR Á¿ì ÅäÃⱸ AC(L ) 1 250V/T3.33K (2012) 4 5 R04Y 5.0M 10K .1K 3 6 L01Y 12uH 1 1 BUS(A) 4 5 ZNR01Y 10K 1 3 1 3 C04F 103 C02F 103 R02F 8 RD 1 1 1 4 7 5V 2 2 2 3 R14D 1K C14D 103 R16D 2. Only for training and service purposes R01B FLASH:TMP86FS49FG P72(AIN12) AD_CH10 R01H R02H R03H 12.1K LGE Internal Use Only 1.1K CC_SB1 CC_SB2 CC_SB3 S_B1 S_B2 S_B3 7 7 State 5V RY01J G5NB-1A 8 8 Error Data_IN R04J 100 R03J 10K R01J 150K/1W CN_Contact BR-762C-4P OSC01B 16MHZ CC_TX Áß Ó_ TX D01J 1N4148 4 4 4 4 9 9 CN-UPG SMW-200-03P 1 1 +5V PC01J TLP421 R02J 150K/1W Power Y/N Fuse 250V/1.15A.Schematic Diagram +5V R01E. 7K +5V IC04D 26 TEST 27 P21 C04M 104 P36 P35 7805 39 38 28 P22 LEV_B_2 LEV_B_3 RY-4WAY S-TRANS CN-GATE2 D10D 17 + P34 9 37 R08D 1.2K + + + LEV_B_4 CN-4WAY 29 RESET 30 XIN 6 5 4 3 2 1 6 5 4 3 2 1 15 V P33 P32 C03D 2200UF 35V 16 36 35 LEV_A_1 LEV_A_2 C15D C16D 103 104 C05D 220UF 16V RY-HEATER C06D 220UF 35V 15 V + C04S 10UF C05S 10UF + + C06S 10UF D11D C07D 220UF 35V 15 8 C14D 473 R09D 1K C04D 680UF OSC01B 16MHz 31 XOUT R01B.3W R02V 1K 1 15 V + D01V 1SR139-600 R03V 33K R04V 10K Q01V C3198 4 R11Y.1/4W 3 Q01Y C3198 D06D 1N4937 C02D 47UF 50V + ZD01Y 20V 1W R01Y 70K.100 + R01A.25A 3 .1K 7 7 R02T RX_D TX_D RY-PWR F0_IPM 15 P06(EMG1) 16 P07(CL1/PDW1) P51(INT4/TC4) P50(INT3/TC3) C31K 15uF. A3UW246FA0.65K.10K IC01Y TLP621 R04Y 2.7K CN-SV C07S 104 R01S 20K C08S 104 R02S 20K R03S 20K C09S 104 C10S R04S 104 20K C11S R05S 104 20K C12S R06S 104 20K C03A 10uF/50V D08D RU2YX IC04M KIA65084 +12V D09D 1SR139-400 4.1.27uF + 100K.1% C01N 100UF + 3 4 1UF/50V C11H~C15H 18K 6.4. 40A 3 2 1 1 1 1 1 2 2 P U V RED DSA-362MA 561 WHITE Schematic Diagram L2:1.7K IC01A KIA7036P C04A 102 R03A.2K 6.SE012N 14 1 34 LEV_A_3 P30 LED01Y(GREEN) R03D 47K 3W 33 R05Y 15K R03Y 82K 1/4W R02Y 70K. All right reserved.5W NF01J MOTOR RC05M 9 8 9 8 Vupc Up Vup1 Vvpc Vp Vvp1 Vwpc Wp Vwp1 1 2 3 4 5 6 7 8 9 10 11 12 Vfo Ufo Wfo Un 16 Vn1 14 Vn 17 FUSE 250V/5A C09D 330UF 35V 10 Br Wn F0 Vnc 13 18 15 19 RY-FAN1_H 2 5 R06D 680.0uF GND 1uF N COMP 400V 2200uF 800V.275V RY-PWR CN-DC CN-PWR 1 1 - 2 2 PTC 4 3 2 1 CN-AC CN-POWER IPM PM50CSD120 + W N B NC 4 HIGH PRESS Comp OLP REACTOR 28A 0.1K 6.1K C02N 103 D05N 1N4148 R01N 680.68mH RM20TPM-2H AC440V/DC1600V. A4UW246FA0.630V H/Press INT Q02Y C3198 RY-FAN2_H IC01V TLP621-BL FB01D FBA04HA900 IC02D TLP621-BL FAN2 RY-DISC R06Y.2K 6.1K LED02T (YELLOW) C01A 102 U1 12 6 RY-FAN_2H U1 11 10 7 23 P16(PDV1) P41 RY-FAN_2L U1 8 9 42 24 P17(PDU1) LEV_CTL_A P40 RY-START +5V R30M CN_Test 2 +5V 41 25 P20(INT5/STOP) LEV_ENABLE P37 40 LEV_B_1 Q01Z KRA107M R12M~R22M 4.1W + CN-FAN1 CN-GATE1 4 Vcc In GND In Vcc Fo GND Vcc In GND In TEMP Out Si Out Si Out Si GND GND GND Out Si GND Vcc GND In Vcc Fo In Fo Fo Vcc Fo GND Fo GND Vcc In Fo GND RY-START Out Si GND Out Si GND Out Si GND C01D 68UF 400V R02D 82K.0. A2UW166FA0/1.3W RC03M D12D C11D.2K 12.450V 50 49 10K Q01T RX_C TX_C IPM_5V_ENB 17 P10(INT0) P47(SDA/SO) 107M C04T 103 R04T R01T 10k R31K 1M.5mH L1:2. A4UW306FA0.25A 561 S 821 (102) R 472 332 500V.1KV R04D 10.1/4W 3 C13D 680P D07D 1N4937 50V FAN1 G6551 ZNR01D ZNR561D14 RC04M R07D 1 .100P.1/2W C02J 104.1M P31 32 VSS DC LINK IC03D.60Hz CN-INPUT Copyright ©2007 LG Electronics.1K C08D 220UF 35V 12 2 C12D. 1% OUT_Air CN_TH2 1 2 3 4 4 3 2 1 5V 5V OUT_Pipe DISCHARGE CN_TH3 2 1 1 2 IC01M GMS81516 1 P70(AIN10) 2 3 4 5 R16H R17H R18H R19H R20H C17D 103 6.275V C01J 104.250V 19 P12(INT2/TC1) P45(SCK) RY-SV 1K 15 46 20 P13 R07T U1 4 RX_A P44(TxD) RY-FAN_1H 21 P14(PPG) 45 1 1 1 2 3 IC10S 4 3 2 8 8 1 2 3 4 R08T 3 9 9 47uF/50V 4 6 6 7 7 4 5 5 TX_A P43(RxD) 44 5V BUS_ADDR_LEV 2 3 10K 1K R06T 14 IC01S 3 2 4 IC06S IC05S IC07S IC09S IC02S IC08S IC03S IC04S 13 TLP559*6 TLP521*4 1 5 6 8 2 +5V R02A.1W R00D 1M.0uF 821 (102) 500V. Only for training and service purposes +5V 1/4W +5V 2. Inc.0mH Power Relay BLACK 1uF 472 332 1W/1M 2.150 ~ + 56K U1 5 RY-FAN_1L 22 P15(DVO/TC2) P42 43 LEV_CTL_B RC01M LEV_CTL_C RY-SV RC02M CN_TH5 TX_F + + + + + 1 1 CN_TH4 1 1 CN_TH3 SUCTION TSUP_E R06H~R10H 1K C16H~C20H 1UF/50V LGE Internal Use Only CN_TH1 1 2 3 4 5 6 8 9 2 3 4 5 6 8 9 1 + D13K 100D-9 NTC01K 1SR139-600 2 2 1 1 2 2 1 1 2 2 1 1 G/Y 3 3 2 2 1 1 G/Y 3 3 2 2 1 1 .2K 6. A2UW186FA0. 270 P62(AIN02) H/Press INT 8 P77(AIN17) 58 RX_F P61(AIN01) 57 4 4 Q01M KRC107M 2 2 W2 V2 U2 W1 9 P00(W) 10 P01(V) 11 P02(U) 12 P03(W) P60(AIN00) VREF VASS P54 V1 U1 13 P04(V) 14 P05(U) 18 U1 1 56 55 54 53 P53(HPWM0) P52(PWM4/PDO4) RX_E +5V GND TX_E 52 51 5V C06H 104 C07H 104 C08H 104 C09H 104 3 3 4 4 C10H 104 311V +5V R03T.2W MAGNETIC S/W 480V /40A 472 332 1uF 1uF 1W/1M 2.2K 6.3W LEV_A_4 RY-FAN2_L CN-HEATER + 7 7 MOTOR 7 6 5 4 3 2 1 7 6 5 4 3 2 1 15 V + 13 D05D EG01C R07Y.1) A2UW146FA0/1/2. Outdoor Unit .2K 12.6K 1/4W R05V 10K D01D~D04D 1SR139-600 R01D 27.0uF 821 (102) 500V.2W CT01N/30A 1:3000 472 332 1W/1M 2.2K 1/4W C01Y 222 +12V R01V 62K.3W RY-DISC R06V 1K R04M~R20M 68K RY-FAN1_L C01V 102 1/4W D13D 11 CN-FAN2 C01S 10UF + + + C02S 10UF C03S 10UF IC01D FB02D R05D 5. A3UW186FA0/1.2K VDD P71(AIN11) P72(AIN12) P73(AIN13) P74(AIN14) P75(AIN15) 6 64 +5V P67(AIN07) P66(AIN06) P65(AIN05) P64(AIN04) P63(AIN03) 63 62 61 60 Pipe F OUT_AIR + + + + + 4 4 TSUP_D TSUP_C TSUP_B TSUP_A 3 3 OUT_PIPE TSUP_F C01H 104 C03H 104 C04H 104 C05H 104 C02H 104 2 2 CT_AD DC_LINK D01M EG01C 59 7 P76(AIN16) 3 3 R10T~R15T. A4UW306FA1 +5V 5V D06N 1N4148 D01N~D04N 1SR139-600 ~ + CT01N Discharge Suction 2 2 3 4 R01H~R05H 1K ~ 1 R11H R14H R15H R12H R13H 1 CT_AD R02N.473.1/2W 48 12V RX_B RY-HEATER TEST S/W R05T 17 U1 16 2 BUS_COM CN-IPM U + V W U_ V_ W_ Fo 5V C01T 103 C02T 103 C03T 1K LED01T (RED) +5V 18 P11(INT1) P46(SCL/SI) 47 TX_B RY-4WAY U1 3 C13K 471.380V.25A 1uF 1uF T 400V 2200uF + 100K.R12Y 56K. 5% R07V 10K 2012 C3 C16K 102K 2012 +5V IC12K TLP421(Dip) 4 1 RXD-6 3 2 C17K 102K 2012 R25K 10K PTC R37K 30K 1W D08K D02K 1N4007 R05K 50.60Hz Copyright ©2007 LG Electronics.5K 10 P03/AN03 P05/AN05 P07/AN07 P02/AN02 P04/AN04 P06/AN06 5 LED02G A2 R07P R18P R08P 5 4 2 R19P P96 P95 P94 P93 P92 P91 P90 BYTE CNVss P87 P86 RESET Xout Vss Xin Vcc1 2 AVcc P10/AN0 P101/AN1 P103/HEAT_SINK P105/PIPE P107/DISCHARGE1 P97 Vref AVss P102/AN2 P104/OUT_AIR P106/SUCTION 7 6 1 2 SCL SDA WP P01/AN01 P00/DISCHARGE2 11 B7 8 11 6 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 LED0 LED1 PCB Auto Check 6 LED1 2 3 4 IPM Fault Signal P14 INT3 INT4 INT5 P20/AN20 P21/AN21 P22/AN22 P23/AN23 A1 N C07Z. Only for training and service purposes VDC +5V TX_FLASH TX 2 2 3 3 .1K.7K 4.DC12V R04C 4.3UF.2012 Nw C(SC) C(FOD) OUT(VL) VFO COM(L) VFO CFOD CSC 20 VCC A0 A1 2 IC09M KIA65084 3 3 LEV5 19 CS 4 50 35 38 36 46 32 33 34 41 31 3 4 CS-3 18 B0 A2 RXD-5 TXD-5 RXD-4 TXD-4 RXD-3 TXD-3 RXD-2 TXD-2 RXD-1 TXD-1 1 4 18 5 5 7 6 C01Z 471 C02Z 122 C03Z 471 C04Z 122 C05Z C06Z 122 471 27 IN(WL) Nv 17 B1 A3 RX_Flash TX_Flash 2 5 17 16 B2 R17T 4.1/4 1% C01C 103K 50V C07K 102K 2012 R08K 1K 2012 R10K 10K +5V R14K 30K 1W 3 2 D03K~D08K 1N4007 R15K 30K 1W IC03K TLP421(Dip) 1 4 D03K RX_JIG_PC R01M~R08M 68K R07K 680 2012 2 3 R06T 1K R05T 4.1/4 5% INPUT VOLT 7 1 ~ CN-COIL2 4 2012 4 +5V IC04K TLP421(Dip) 4 1 BD01S RBV2506 RBV1506 C01S 680UF 400WV C02S 680UF 400WV + + + + D2 C03S 680UF 400WV C04S 680UF 400WV ~ D1 R09K 1K 2012 C09K 102K C03C 25V.1/4W.02J SVC561 NF01J J51~J56 J21~J26 OUT NC +15V +5V R01F RY-PWR G4A-1A-PE C07J 472M C05J 332M L01D 12uH R04J 3 D D201 12 OUT IC04D 1K 2012 C09J 9 NC 7805 R03F 4.47uF AC(N) C10K 102K 2012 R13K 1.1/4W.1K.5k C06S 152J D01S 1N4007 IC09K TLP421(Dip) 1 4 R33K 30K 1W AC_COM D06K +5V CN-COM R40K 680 C07S 2 3 1 C08S 102K IC02S TLP421 +5V +5V D01Y 1N4148 IC01V TLP421_BL D01V 1N4007 R02V~R05V 47K.1uF +120 R04S 0.2K.2012 R17Z R03Z IN + PWM ENABLE1 29 U VS VS(U) P35/A13 CS-1 P75/W P74/W P73/V P72/V RXD0/P62 TXD0/P63 CLK1/P65 RXD1/P66 TXD1/P67 RST1/P64 EPM/P24 CE/P50 P36/A14 P37/A15 P40/A16 P41/A17 P42/A18 ENABLE2 ENABLE3 8 CS-2 CS-3 9 C02M 104 2012 11 14 R11M 10K IC06M 74HC245AF QE +5V RX-CC TX-CC R02T 4.5K 1/4W 1% 3 2 R34K 30K 1W 2 2 3 3 TB2 R01Y R02Y 1% 270K 1/2W 1% 270K 1/2W IC11K TLP421(Dip) LOW-V C01Y 103K 50V.7K R01Z V IN VS(V) VB(U) IN(VH) +5V RY-FAN(B)_L PSC(On/off) RY-FAN(A)_H RY-FAN(A)_L A7 5 6 7 12 11 10 PSC (On/off) RY-FAN(A)_H RY-FAN(A)_L GND 9 10 B5 13 +5V B6 6 13 3 3 LEV4 12 7 12 4 4 RD 3 VB VCC VCC(UH) 3 WCN-U RD 13 12 11 B7 8 11 5 5 9 10 OUT COM C11Z IN(UH) C12Z R16Z 20A :47.1W C2 C2 G G C02K 150uF/100V CN-CP(L) N N 1 1 L L CN-CP(N) 1 1 C1 C1 20A/250V FUSE WCN_P(L) BR C02J 222M C01J 1uF/ 275VAC C03J 222M GND GND GR/YL N N WH WCN_P(N) BL L L BK TB1 AC-POWER AC220~240V/50.1/4 5% D01D 1N4937 C04D 470UF 35V L02D 12uH C08D 103 50V +15V C01V 102K 2012 N N L L AC_COM C3 R01V 47K. All right reserved.50V RESET OSC01B 4MHz R01B 0 2 + R01A 4.02F KRC104S(Chip) Q03F.2012 R03Y 4.8mH/ 9A 11mH/ 14A AC (N) R10T 1K R26K 1. INDICATOR 16 B2 3 A4 6 16 1 LED01G : RED_10자리 LED02G : GREEN_1자리 1 2 C05P 102 +5V C09D 104 L03D 12uH R01L 4.7K.5K 1/2W 1% C06P~C08P 102M RX_JIG_PC 1 2 TX_JIG_PC C04M 104 3 3 FAN FG 3 32 VCC OUT COM C07Z IN(WH) 2012 P VB VB(W) R07F 1K C03F 102 20 VCC 22 2012 IC08M KIA65084 A1 4 4 LEV3 VCC(WH) 21 + C08Z TXD-6 C01P~C03P 331 2012 31 VS(W) W VS IN R14P 7.5K/1W + IN GND R02D + 2K 1/2W R102 C05D 220uF 35V 40 OHM +15V +5V C01K 102/100V 1 R101 13 C101 FAN ON/OFF Q01F D101 Q03F R06F 4.7K P43/A19 P26 39 P25 40 P23 42 P22 43 P21 44 P51 45 P46 48 P45 49 P44 P47 47 P60 P61 37 CN_LEV5 +5V C19Z 400VAC 1.5% C15K 102K 2012 2012 2012 2 3 1 ZD07K 68V 102 2012 C14K 102K 2012 +5V IC10K TLP421(Dip) 4 1 R20K 1K 2012 R24K 10K +5V 4 1 R28K 1.7k 2012 2012 COM(L) 2 VCC(L) 12 B6 GND R06K AC_COM 7 10 12 4 4 24 NC 1 11 B7 680 8 11 5 +5V R01C 12K.7K.Schematic Diagram DISCHARGE2 1 1 2 2 +5V CN-TH4 3 R16H DISCHARGE1 R15H R12H 6.7K R11Z 2K R12Z 4.04F KRA106S(Chip) C01F 103k 630V RY-C/COMP G4A-1A-E CN-PRESS Vs CN-MOTOR1 7 7 YL 6 6 BL FG 5 5 WH Vcc 4 4 BK GND 3 3 2 2 1 1 RD CN-FAN(A) CN-FAN(B) CN-P/ICE CN-4WAY CN-HEATER CN-OIL/S CN-HOT GAS R03J 20 1/4W.7K.T R19K 1K 2012 2 Q01T KRA105 R06S 4.7K 19 3 CS 5 5 CS-2 18 B0 1 18 6 6 20 1 R14Z C03A 104 23 D02Z VB VB(V) 18 17 YL 1 1 WCN-W YL VCC VCC(VH) OUT COM COM(H) C09Z C10Z +5V +5V + MITSUBISHI M16C/62P Group IC02A R01T 4.5% SURGE DA-38-302MT-A21 2 2 1 1 4 4 3 3 2 2 1 1 3 3 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 BK WCN_GND2 BK WCN_GND1 H/P L/P DC FAN MOTOR FAN MOTOR(L) FAN MOTOR(R) COMP (single) COMP_AC_IM + R21K 1K 2012 R29K 1.5% J27~J32 R02J 20 1/4W.1% 2012 18K.1% C06K 102K 2012 2012 2 3 5 ZD03K 68V +5V 9 IC02K TLP421(Dip) 4 1 10 R19Z 20K IPM Fault Sig.5K A6 +15V LED01G A7 8 9 13 B5 6 13 4 85 84 83 82 81 4 LEV2 12 B6 7 12 5 87 86 GND R02G 17 1. C15Z 104Z 25V 2012 2012 2012 C16Z 47uF 50V C17Z 102 C18Z 102 +5V R12K 1.7K 2K R02Z R09Z 2K R10Z 4.7K R05F 10K RY-FAN(A)-H JQ1A-12V RY-FAN(A)-L JQ1A-12V RY-FAN(B)-L JQ1A-12V C06D 103 R202 PC201 AC (L1) FB 1uF/ 275VAC C07D 103 BP S PC201 C102 C04J Q02F 2012 2012 1M C08J 472M R02F PWM 50V 50V 1K 2012 2) A6UW406FA0 RY-FAN(B)-H JQ1A-12V 5 6 TNY 268 R201 + + + C03D 220uF 10V D202 Q04F R04F 5._COMP_BLDC Nu IN(UL) 25 NC IN(UL) IN(WL) OUT(UL) IN(VL) 3 +5V IN(VL) 5 4 15 B3 4 15 1 1 14 B4 5 14 2 2 26 LEV6 IC01K TLP421(Dip) 1 4 COM(L) VCC R18Z 4.05 R05S 71.7K RX 1 AC_COM 1 CN_JIG_PC VDC TX_JIG_PC TX 2 2 3 3 ZD04K 68V 3 AC(L) BD01C DF08M 5 ~ + +5V C08K 102K +5V D02C 1N4148 D01C 1N4007 R07C 1K.7K R30K 30K 1W RX_FLASH RX 1 1 CN_FLASH +15V +15V IC01S TLP251 IGBT GT50J102 7 2 6 3 4 2012 C11K 102K R03S 1.9K.1/4 1% R02C 47K.5K 1/4W 1% R36K 30K 1W D01K 1N4007 R01K~R04K 11K/3W*4 ZD01K.1% 2012 12.1K 1/4W C02F 10UF /10V 6.7K P85/NMI P84/INT2 P83/INT1 P82/INT0 P81/U P80/U P24/AN24 P25/AN25 P26/AN26 P27/A7 Vss P30/A8 Vcc2 P31/A9 P32/A10 P33/A11 P34/A12 RY-P/ICE RY-HEATER RY-HOT GAS RY-4WAY IC02M KID65004AP 1 2 3 RY-FAN(B)_H A2 A3 16 15 14 4 13 RY-HOT GAS A4 RY-4WAY A5 RY-FAN(B)_H A6 RY-FAN(B)_L 4 5 6 7 8 17 B1 2 17 16 B2 3 16 CN_LEV4 15 B3 4 15 1 1 14 B4 5 14 2 2 BL 2 2 WCN-V BL VS 30 16 15 19 D03Z R15Z R07Z R08Z 4.10Z.7K INPUT VOLT R02H 20 VCC A0 A1 A2 2 3 IC07M KIA65084 4 4 LEV1 19 CS 5 5 CS-1 OUT AIR 4 + + + + + 1 2 3 18 B0 4 1 18 6 6 HEAT SINK 1 PIPE LENGTH 1 2 R01P~R04P 470K 1/2W 1% R05P~R10P 2012 C02T 102K 2012 17 B1 A3 5 2 17 CN_LEV2 ER_CODE.09Z.7K 1/4W NF02J AC (L) FAN FG ZNR01J.5K 1/4W 1% RXD-6 +5V R02A IC01A 100 2012 KIA7036P 3 C01A 3.5K 1/4W 1% R32K 30K 1W 1 CN_CENTRAL TX-CC TX 2 C.7K 2012 3 1 2 3 2 3 4 1 CN-TH3 C06M~C11M 104 R09M 10K IC04M 74HC245AF QE +5V C07H C08H C11H C09H C10H C12H CN_LEV1 +15V 1 1 SUCTION 4 +5V 2 2 C03M 104 1 3 3 1 2 3 SW1 OR1 LONG C06H 10uF 50V 50V LOW-V 1 2 3 4 + C05H 10uF 50V 50V 50V 50V JIG POINT R14T 1K 2012 10uF 10uF 10uF 10uF R03N 20K 2012 C02N 102K 2012 C04H C02H C01H C03H C.02K 36V.65K 1% 1/6W +5V AC (L) 6 1 ~ D02N 1N4148 2012 2 3 ZD06K 68V C12K 102K 2012 +5V IC08K TLP421(Dip) 4 1 C01T 102K 2012 RX 1 R27K 1.7K 2012 3 R01N 1K 1% 1/6W R07S 20K 2012 3 + D01N 1N4148 1 4 3 2 C01N 220uF 10V(RN) PSC F/Signal 4 C13K 102K 2012 4 R23K 10K +5V D4 C09S 0.1% 30A :56.1% Q01C KTC3198Y (DIP) TRANS1 50Hz.7K R03A 1K 2012 C02A 102 2012 R18T 4.1/4W.7K R16T R15T 4.1/4W.5% J57~J62 R01J 20 1/4W.5K 1/4W 1% 3 2 R16K 30K 1W R07T 1K RX_JIG_S R17K 30K 1W R05C 12K.12Z : 47uF 50V 6 12 +5V R20P R18P~R20P 1K 2012 A0 CN_LEV3 R10M 10K RY-P/ICE RY-HEATER QE A0 C01M 104 2012 5 +15V 1 1 +5V R13Z~R15Z : 20 1/4W 5 2 IC05M 74HC245AF 1 2 2 D01Z~D03Z : 1N4937 6 +15V D01Z R13Z R11P~R13P 15K 1/4W 1% C04P 104 CN-WRITER IC01P KIA339A 7. Inc.1% 2012 18K.7K +5V +5V 20K 2012 CN-TH1 5V : NORMAL GND : LONG C01L 103 2012 R15P~R17P 4.1% R04Z R05Z R06Z R01Z~R06Z 100 2012 R20Z 390.2K.5uF RSC +15V 1 1 C05M 104 1 2 2 OUT(WL) 28 10 9 8 C14Z 104.1% R06C 2.1% 2012 R08H R07H R06H R05H R04H R03H PIPE CN-TH2 6.T NORMAL R01H R01H~R08H 1K 2012 C07H~C12H C102*7 R04T 4.11Z : 104K 2012 R09P 3 4 3 EEPROM M24C08 9 16 15 5 INT_HP PSC F/Signal Phase Control DC Fan On/off RY-PWR RY-C/COMP 10 RY-PWR RY-C/COMP RY-OIL/S 14 6 7 8 13 12 11 10 RY-OIL/S 7 1 SPM2 FairChild FSAM30SM60A FSAM20SM60A 4 R21P R10P C08Z.1W.1% C02C 102 + 2012 RX 1 R11K 10K 2012 1 D04K IC05K TLP421(Dip) +5V 1 4 CN-COIL1 AC (L1) D4 ~ - + C03T 102K 2012 R38K 680 2012 2 3 2012 AC_COM R08T 10K TX_JIG_S TX CN_JIG_S 2 2 3 3 ZD05K 68V +5V +5V D3 4 IC06K TLP421(Dip) 4 1 4 REACTOR 26.8V ZD01F C06J 332M 1UF 275VAC 1/2W RY-P/ICE G5NB-1A RY-4WAY G5NB-1A RY-HEATER G5NB-1A RY-OIL/S G5NB-1A RY-HOT GAS G5NB-1A AC (N) 7 GND u-POWER MODULE uRM1515-2B C10D 102M GND C01D 1000UF 35V C02D 470uF 25V Q01F.1% 2012 R14H R13H R10H R09H 4. 2012 3.5K 1/4W 1% Phase Freq R03C 10K.1% 2012 1.7K A4 A5 +5V A6 A7 6 7 8 9 +5V 3 16 CN_LEV6 Inv.2K 1/4W AC (L1) 4 PSC On/Off + 2012 R22K 10K +5V +5V IC07K TLP421(Dip) 1 4 R31K 30K 1W AC_COM D05K R11T 1K 2012 RX-CC R39K CT01N Current Trans 3 ~ R12T 4.5K 1/4W 1% R18K 1K 2012 3 2 R09T 4.1% 2012 R11H 12.7K 1/4W(or 2012) G +15V +5V 15 B3 A5 TX_JIG_S RX_JIG_S 7 4 15 2 2 14 B4 5 14 3 3 W V U R05P R06P 9 8 14 3 1 8 100 99 98 97 96 95 94 93 92 89 88 90 91 2012 2012 Vcc IC01M KID65004AP LED0 1 18 R01G 1.7K +5V 4 4 C05S 104 8 1 680 BD02S RBV1506 D2 C09S 152J ~ D3 + 5 G ~ BD01N DF08M D1 R01S 10k 1/4W R02S 220 1/4W R02N 1.7K R02L 4.1% C13Z 102K.5K.151 - 13 B5 6 13 3 3 + LGE Internal Use Only 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 .1% INT_HP 1 4 R35K 30K 1W AC_COM D07K 4 5 4 5 C4 C4 G G 6 R41K R08V 1K 680 TXD-6 3 2 2012 2 3 6 ZD08K 68V R06V 1K. IK R22K 1K 5 5 LEV4 8 11 6 6 9 10 C10B 103 TX_D4 ERA15-06 R03M 10K IC09K(TLP621) D05K D11K ERA15-06 5V C003M 104 12V 1 R29K 82K/3W 1 IC07M KIA65084 CN_LEV 1 R23K 1K 2 IC03M QE 2 1 VCC 18 RX_D4 C10K 102 25V R17K 10K R11K.5K ERA15-06 2 B5 2 5 14 3 8 9 10 13 12 11 B6 B7 3 6 13 4 4 TX_D1 IC03K(TLP621) D02K D08K ERA15-06 7 12 5 5 LEV6 8 11 6 6 9 10 C08B 103 RX_D1 C04K 102 25V R14K 10K IC06K(TLP627) R03K 1.IK 3 IC12K(TLP627) R06K 1.5K R10K.IK R19K 1K R25K 82K/3W CN-DATA 1 2 3 4 2 3 4 5 6 5 6 1 C07B 103 B2 B3 B4 A6 A7 GND 1 1 CN_LEV 6 C02K 102 25V R13K 10K IC04K(TLP627) R02K 1.5K ERA15-06 3 1 A0 A1 A2 2 17 4 20 2 245 4 19 3 4 IC11K(TLP621) A3 D06K 3 CS_LEV12 B0 16 5 18 17 5 A4 5 LEV5 4 B1 15 6 6 TX_D5 C11B 103 16 6 R12K.5K ERA15-06 18 17 16 6 A5 A6 B1 B2 C09B 103 1 15 7 14 8 13 B3 B4 B5 1 CN_LEV 4 TX_D3 IC07K(TLP621) 2 2 5 14 3 D04K 3 A7 R28K 82K/3W D10K ERA15-06 6 13 4 9 GND 4 12 10 11 B6 B7 7 12 RX_D3 C08K 102 25V R16K 10K IC10K(TLP627) R05K 1.IK R24K 1K R30K 82K/3W D12K ERA15-06 B2 1 15 A5 A6 B3 B4 1 CN_LEV 2 7 14 2 B5 2 5 14 RX_D5 C12K 102 25V 3 R18K 10K 3 8 A7 GND 13 9 10 12 11 6 B6 B7 13 4 4 7 12 5 5 LEV6 8 11 6 6 9 10 C12B 103 Copyright ©2007 LG Electronics.152 - R09K.IK R21K 1K R27K 82K/3W D09K ERA15-06 5 5 LEV3 4 15 6 6 LGE Internal Use Only . Only for training and service purposes Schematic Diagram . All right reserved.IK R20K 1K R26K 82K/3W R02M 10K 5V C002M 104 12V 1 IC06M KIA65084 IC02M 1 CN_LEV 3 2 2 TX_D2 IC05K(TLP621) D03K 1 QE VCC 18 3 1 A0 A1 A2 A3 3 20 2 245 2 CS_LEV12 17 4 19 3 4 5 A4 4 3 B0 16 RX_D2 C06K 102 25V R15K 10K IC08K(TLP627) R04K 1. Inc.5K ERA15-06 R08K.5K ERA15-06 IC02K(TLP627) 1 VCC 18 3 1 2 A1 245 3 20 19 3 A2 A3 2 CS_LEV12 17 4 4 3 B0 16 TX_D0 IC01K(TLP621) D01K D07K ERA15-06 5 18 4 5 A4 A5 5 LEV5 4 B1 15 6 17 16 6 15 7 14 6 RX_D0 R07K.BUS_ADDR_LEV R01M 10K 5V C01M 104 12V 1 IC05M KIA65084 IC01M QE A0 1 CN_LEV 5 2 2 BUS_COM 5V DC310V R01K 1. Schematic Diagram 13 C101 R101 GND R102 IN 1 +12V D101 IC04D 7805 9 D201 R201 R202 PC201 L1 12uH 12 OUT D OUT 3 NC TNY 267 FB NTC D05D SCK102 1N4007 (DIP) + C01D 4.7K R14K 1 4 5 6 D02Y SS12 7 1 2 3 4 2 3 U02Y 6N137 8 7 6 5 6 104 C01K 5 IC02K(6N137) TXD1 CN_OUT 5V TXD0 SEL RXD0 R01Y 0.62K 1 2 3 4 6N137 8 4. Inc.33K U01Y SN65LBC176 R08Y 1K 1 2 3 4 C07Y 104 R02Y 5.62K 15pF C04K RXD1 3 3 GND 4 4 5V_EXT 5 5 12V_EXT R15K 1K/0.153 - TXD0 1 6N137 8 C01X 102K R01X 1K 104 C02K 2 7 RXD0 RXD1 4 3 6 5 6 7 8 4 3 2 1 R06Y 0.62K LGE Internal Use Only 5V .7K C06Y 104 U04Y 6N137 3.7K ZNR01Y SVC220D-07B LED1 R04Y 5. All right reserved.7K 5V 1 C03A 102 KIA7036P 2 3 R03A 120 R01A 1K IC01A 3. Only for training and service purposes 5V V5 .2012 1M 1 RX RXD2 C02X 102K 12uH L01D 12uH L02D 2 2 TX 3 3 GND R03X 1K 2012 OSC01B 14.62K U03Y 6N137 C08Y 104 R03Y 4.7uF 450V BD01D DF08M N/F01N 11mH/1.1K R09Y 1K R07Y 0.7uF C01A C02A 104 ATMEGA162 RXD0 5 5V 30 29 AVCC 6 TXD0 7 28 27 PD2 PD3 8 9 26 25 PA7 R04T 10K 2012 AGND SWITCH V5 R02M 1K OMRON_B3WN OUT 8 7 6 2 3 4 IN SW4 SW3 SW2 SW1 S10R S20R S30R S40R PD5 11 12 4*K1 W8/1 23 13 14 Xtal1 15 Xtal2 16 GND 17 VCC 18 RXD2 19 TXD2 20 21 22 ON 5 1 SW DIP-4 V5 PD4 10 24 R05T 10K R08S R07S R06S R05S C05H C04H C03H C02H CN_JIG 4*K01 W8/1 4*301 TXD2 R06T 10K R01B 1 C03X 104.1K 104 8 7 6 5 CN-COMM 1 2 3 4 4 3 2 1 TXD1 15pF C03K 1 1 RX 1 2 3 4 8 7 6 5 1 2 3 4 8 7 6 5 SEL R12K 1K/4. Central control unit Schematic diagram SEL SCK 5V 2012 2012 IC01K(6N137) 5V_EXT 5V IC05D 5V_EXT 7805 BR1 1 o o 2 3 o o 4 5 o o 6 7 o o 8 C10D 220uF 10V RXD1 GND TXD1 VCC + CON5*2 RXD0 44 43 MOSI 1 MISO 2 42 41 40 39 38 37 36 35 34 33 32 SCK 3 RESET 4 31 PA4 PA5 PA6 SEL 9 o o 10 TXD0 R01G 470 R02G 470 R03G 470 R03T 1K LED01G 5V 5V LED02G LED03G R02A 4.15A C05D 220uF 10V + + C04D 103 50V C08D 103 50V R01D 1/2W BP PC201 + 1/4W S C102 5 NC 6 R02D 300K C01N 104 275VAC L 1K 7 D202 N C07D 220uF 25V C06D 470UF 25V GND GND CN_PWR u-POWER MODULE uPM1512-C2 C09D 102M D05D 1N4007 D05D 1N4007 D05D 1N4007 5V_EXT 5V 5V C09Y 104 U05Y MAX253 Trans01Y D01Y SS12 G C04Y 22uF/35V IC03D KID78L05BP I O 7805 C02Y 104 C03Y 22uF/35V C05Y R13K 1K/0.7456 5V 2012 C04X 104 4 4 5V Copyright ©2007 LG Electronics.5A ZNR01N SVC561D-14A FUSE_1 250V/T3.7k 5 2 2 TX R05Y 4.6V 4. All right reserved.Schematic Diagram Wiring Diagram 1. Inc. Art Cool Deluxe Type Indoor Unit A/C MOTOR CN-MOTOR CN-L/R BLDC MOTOR MAIN PCB ASM TRIAC STEP MOTOR OR MOTOR SH-CAPA CN-U/D BK STEP MOTOR BR YL GN/YL ZNR CN-HVB RD H. Room Type Indoor Unit -SQ/SR/ST chassis AC PCB ASM CN-MOTOR 2.BG/BT chassis WIRING DIAGRAM ROOM.154 - LGE Internal Use Only 1(L) 2(N) BL 3 RD TO OUTDOOR UNIT . CENTRAL CONTROL REMOTE TELE CONTROL THERMISTOR CONTROL THERMISTOR THERMISTOR DRY CONTACT A/CL UNIT PTC HEATER CN-CC ZONE CONTROL CN-ZONE CN-PIPE1 CN-REMO CN-PIPE2 CN-ROOM CN-AIRC CN-PTC CN-OUT VENTILATION E/HEATER 4 5 FLOAT S/W CN-PIPE1 GN/YL BR FUSE CN-DISP CN-MOTOR CN-DPUMP CN-POWER OPTION RF-REMOTE CONTROL 3854A20419A 5. IN-PIPE. Art Cool Type Indoor Unit AC PWB ASM FAN MOTOR WH BK YL RD CN-U/D CN-TH1 CN-TH2 DC PWB ASM CN-GND1 CN-HVB(BL) CN-LR2(WH) CN-LR1(WH) CN-UD(BL) CN-TH1CN-TH2 DC PCB ASM THERMISTOR(OUT-PIPE) THERMISTOR(IN-PIPE) THERMISTOR(ROOM) THERMISTOR(OUT-PIPE) THERMISTOR(IN-PIPE) THERMISTOR(ROOM) CN-MOTOR1 STEP MOTOR CN-ACDC1 CN-ACDC2 STEP MOTOR STEP MOTOR RD ZNR ZNR Z CN-POWER GN/YL BR BL RD FUSE 250V 2A FUSE 250V 3.15A H. Duct Type Indoor Unit .V.V.B RD A/CL BK BK CN-TH2 THERMISTOR(OUT-PIPE) CN-TH1 THERMISTOR(IN-PIPE) THERMISTOR(ROOM) CN-POWER FUSE 250V 2A BR BL GN/YL RD CN-VFD DISPLAY 1(L) 2(N) 3 4 TO OUTDOOR UNIT FORCED OPERATION S/W CN-MAIN CN-SW/1 CONNECTOR PCB ASM CN-SW/2 CN-SW/3 LIMIT S/W-1 LIMIT S/W-2 CN-STEP1 CN-STEP2 INDOOR WIRING DIAGRAM 3854A20135X SUC STEP MOTOR-1 SUC STEP MOTOR-2 Copyright ©2007 LG Electronics. OUT-PIPE.S4/S5 chassis 4. Room Type Indoor Unit . ASM BK PLASMA AIR CLEAN 1(L) 2(N) 3 4 CN-D1(WH) CN-D2(WH) CN-POWER TO OUTDOOR UNIT SAFETY S/W SAFETY S/W CONNECT PCB ASM DISPLAY PCB ASM 3854A20135Y 3854A20135W STEP MOTOR FORCE S/W 3. Only for training and service purposes . VE chassis WIRING DIAGRAM ROOM.BH/BP chassis 7. Inc. All right reserved. IN-PIPE.TE/TF/TD chassis WIRING DIAGRAM A/CL UNIT CN-DOOR OUT-PIPE.VB chassis WIRING DIAGRAM 9.Schematic Diagram 6. CST Type Indoor Unit . CENTRAL CONTROL REMOTE TELE CONTROL THERMISTOR CONTROL THERMISTOR THERMISTOR DRY CONTACT WIRING DIAGRAM A/CL UNIT PTC HEATER CN-DOOR STEP MOTOR S/W2 CN-CC ZONE CONTROL CN-ZONE CN-PIPE1 CN-REMO CN-PIPE2 CN-ROOM CN-AIRC CN-PTC CN-OUT CN-UD1 VENTILATION E/HEATER S/W1 DC PCB ASSY CENTRAL CONTROL CN-CC AC PCB ASSY 4 RD GN/YL 1(L) 2(N) BL BR TO OUTDOOR UNIT 5 A/CL UNIT CN-ACDC 3 RD FLOAT S/W CN-PIPE1 TO OUTDOOR UNIT HVB CN-HVB GN/YL 1(L) 2(N) BL BR FUSE CN-DISP CN-MOTOR CN-DPUMP CN-POWER CN-ACDC 4 GN/YL FUSE CN-TH1 CN-TH2 CN-FLOAT CN-DISP CNMOTOR CNDPUMP IN-PIPE. CST Type Indoor Unit . Duct Type Indoor Unit . CST Type Indoor Unit . THERMISTOR ROOM OUT-PIPE. THERMISTOR ROOM OUT-PIPE.155 - LGE Internal Use Only 1(L) 2(N) 3 HVB TO OUTDOOR UNIT GN/YL 1(L) 2(N) CENTRAL CONTROL TELE CONTROL CN-CC 3 . IN-PIPE.TE1 chassis 11. CVT Type Indoor Unit . CVT Type Indoor Unit . THERMISTOR THERMISTOR FLOAT S/W DISPLAY PCB ASSY OPTION OPTION RF-REMOTE CONTROL 3854A20419D 3854A20419B 8. ROOM.TH chassis Copyright ©2007 LG Electronics. OUT-PIPE. THERMISTOR THERMISTOR THERMISTOR CN-UD1 DOOR S/W HVB STEP MOTOR CENTRAL CONTROL S/W2 S/W1 CN-CC STEP STEP MOTOR MOTOR STEP MOTOR STEP MOTOR CN-PIPE2 CN-ROOM CN-PIPE1 4 A/CL UNIT CN-HVB CN-UD1 CN-UD2 CN-LR1 CN-LR2 3 RD GN/YL BL BR TO OUTDOOR UNIT CN-ACDC CN-ACDC FUSE CN-TH1 CN-TH2 CN-FLOAT CN-DISP CNMOTOR CNDPUMP IN-PIPE. THERMISTOR THERMISTOR FLOAT S/W GN/YL BL BR FUSE CN-PTC PTC HEATER CN-FLOAT CN-DISP CN-MOTOR CN-DPUMP CN-HVB DISPLAY PCB ASSY OPTION CN-REMO 3854A20419E DISPLAY PCB ASSY FLOAT S/W OPTION REMOTE CONTROL 3854A20419C 10. Only for training and service purposes . CST Type Indoor Unit . Only for training and service purposes .15A CN-AIRC BR BL 1(L) 2(N) RD WH RD BK TO OUTDOOR UNIT H. Inc.B RD BK P/N:3854A20405A 14. CST Type Indoor Unit . All right reserved.TC chassis INDOOR WIRING DIAGRAM TEMP.Schematic Diagram 12. PIPE IN THERMISTOR THERMISTOR FLOAT S/W 13.V.TC1 chassis CAPACITOR BR YL BK GN/YL INDOOR MOTOR CN-ROOM CN-MOTOR CN-PIPE1 CN-FLOAT PIPE OUT THERMISTOR CN-PIPE2 CN-STEP CN-REMO MAIN PCB ASSY OR CN-DPUMP GN/YL DRAIN PUMP STEP MOTOR REMOTE CONTROL CN-POWER FUSE T3.156 - LGE Internal Use Only . ART COOL MIRROR-SE AIR CLEANER 3 4 DOOR S/W (OPTION) DISPLAY PCB ASSY CN-DISP Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes .B2 Copyright ©2007 LG Electronics.157 - LGE Internal Use Only . Inc. SLIM DUCT .Schematic Diagram 15.B1. Schematic Diagram 5. All right reserved. A4UW30GFA0 6.158 - LGE Internal Use Only . A3UW246FA0 INVERTER COMPRESSOR 3.20A L N GND-2 GND-1 BR BR BL BL BR BR BL GN/YL BL BR GN/YL BR T/B 1(L) 2(N) 1(L) 2(N) 3(A) 3(B) Power Supply LEV A LEV B LEV C LEV D LEV E LEV F CN-LEV-A LED1 CN-LEV-B LED2 CN-LEV-C LED3 CN-LEV-A LED1 CN-LEV-B LED2 CN-LEV-C LED3 BRANCH DISTRIBUTOR-(A) CN-ROOM-A CN-ROOM-B CN-ROOM-C L N S L N S L N S L N S CN-PWR BRANCH DISTRIBUTOR-(B) CN-ROOM-A CN-ROOM-B CN-ROOM-C L N S L N S L N S L N S CN-PWR A B C D E F TO INDOOR UNIT TO INDOOR UNIT 3854A20354G Copyright ©2007 LG Electronics. A4UW24GFA0. Inc. A4UW306FA0 INVERTER COMPRESSOR OUTDOOR WIRING DIAGRAM OUTDOOR WIRING DIAGRAM REACTOR OUTDOOR WIRING DIAGRAM REACTOR RD BL YL REACTOR RD BL YL OR RD BL YL RD BL YL BK BK CN-FAN(A) BL BK BR YL OR OR FAN RD BL YL BK BK CN-FAN(A) CN-LEV2 CN-LEV1 U V W CN-COIL1 CN-COIL2 CN-LEV2 CN-LEV1 U V W CN-COIL1 CN-COIL2 BL BK BR YL RD FAN BL YL BK BK CN-FAN(A) LEV U CN-LEV2 CN-LEV2 CN-LEV1 LEV V W CN-COIL1 CN-COIL2 CN-FAN(B) LEV MAIN PCB 4WAY VALVE LEV BL BK BR YL OR BL BK BR YL FAN(A) FAN(B) CN-LEV3 LEV CN-4WAY CN-LEV3 4WV 4WAY VALVE LEV LEV LEV CN-4WAY 4WV 4WAY VALVE CN-4WAY CN-JIG-PC CN-CENTRAL 4WV LEV MAIN PCB CN-HEATER CN-TH2 CN-TH1 CN-TH3 CN-TH4 MAIN PCB CN-HEATER CN-TH2 CN-TH1 CN-TH3 CN-TH4 CN-JIG-PC CN-CENTRAL CN-WRITER CN-CENTRAL CRANKCASE HEATER OPTION CRANKCASE HEATER OPTION CN-TH2 CN-TH3 CN-WRITER CN-TH1 CN-P/ICE (AIR/PIPE) (H/SINK) (DISP-I/SUG) (DISP-C) DEFROST SV (HEATING) LOW PRESS SWITCH SV OIL SEPERATOR OLP COMPRESSOR C R S CN-P/ICE (H/SINK) (AIR/PIPE) (DISP-I/SUG) (DISP-C) SV DEFROST (HEATING) LOW PRESS SWITCH CN-JIG-PC (AIR/PIPE) (H/SINK) (DISP-I/SUG) LOW PRESS SWITCH CN-PRESS CN-PRESS CN-OIL/S WH RD CN-PRESS CN-OIL/S RY-C/COMP BR SV OIL SEPERATOR CN-COM L N CN-GND1 CN-GND2 BR BL WH BK CN-COM L N BK RY-C/COMP CONSTANT CONSTANT COMPRESSOR BR BL RD C R S BR BL RD CN-COM L N WH RD BK BR BL BL GND-1 GND-2 BR BR BL GND-1 GND-2 BK BL BR BR BL BL BK BL BR BL BR BR BL BL BR 1(L) 2(N) 1(L) 2(N) 3(A) 3(B) 1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 5(D) GN/YL POWER SUPPLY A ROOM B ROOM TO INDOOR UNIT POWER SUPPLY A ROOM B ROOM C ROOM POWER SUPPLY A ROOM B ROOM C ROOM D ROOM 3854A20354A TO INDOOR UNIT 3854A20354B TO INDOOR UNIT 3854A20354C 4. Outdoor Unit 1. A6UW406FA0 INV-COMP WIRING DIAGRAM REACTOR RD BL YL OR RD CN-LEV1 BL YL BK BK CN-FAN(A) BL BK BR FAN (A) FAN (B) LEV U V W CN-COIL1 CN-COIL2 YL OR BL BK BR CN-CENTRAL CN-WRITER MAIN PCB TH2 TH1 TH3 TH4 CN-FAN(B) YL CN-4WAY YL 4WV 4WAY VALVE OPTION CRANKCASE HEATER CN-JIG-PC CN-HEATER (H/SINK) (AIR/PIPE) (I/SUC-DISP) (DISP-C) CN-OIL/S WH BK NOISE FILTER RELAY WH SV OIL SEPERATOR(INV) LOW PRESSURE SWITCH CONS-COMP BL RD BR R S C CN-COM CN-PRESS FUSE 250V. Only for training and service purposes . A4UW306FA1 5. A2UW186FA0 INVERTER COMPRESSOR 2. A8UW586FA0 INV-COMP(A) 11. A3UW186FA0. A7UW486FA0. A4UW246FA0 INVERTER COMPRESSOR 10. A2UW166FA0/1 OUTDOOR WIRING DIAGRAM RD BL YL REACTOR WIRING DIAGRAM RD BL YL REACTOR RD CN-LEV1 OR BL YL BK BK CN-FAN(A) BL BK BR OR YL FAN (A) 4WAY 4WV VALVE CONS-COMP(C) BR C BL R S RD RD BL YL BK BK CN-FAN(A) CN-WRITER BL BK BR YL FAN LEV U V W CN-COIL1 CN-COIL2 CN-4WAY CN-LEV2 CN-LEV1 U V W CN-COIL1 CN-COIL2 CN-CENTRAL MAIN PCB TH2 TH1 TH3 TH4 CN-C/COMP2 PTCR OPTION CRANKCASE HEATER OPTION CRANKCASE HEATER_2 LEV CN-HEATER BR BL LEV LEV CN-4WAY CN-LEV3 4WV 4WAY VALVE MAIN PCB CN-HEATER CN-TH2 CN-TH1 CN-TH3 CN-TH4 CN-JIG-PC (H/SINK) (AIR/PIPE) (SUC/DISP_I) (DISP-C) CN-HEATER2 CN-C/FAN CN-JIG-PC CN-CENTRAL CRANKCASE HEATER OPTION CN-COM FM COOLING FAN OIL NOISE FILTER CN-OIL/S SV SEPERATOR LOW PRESSURE SWITCH CONS-COMP(B) WH BL BL BL C R S RD CN-WRITER CN-P/ICE (AIR/PIPE) (H/SINK) (DISP-I/SUG) (DISP-C) SV (HEATING) DEFROST FUSE 250V. All right reserved. A2UW146FA2. Inc.Schematic Diagram 7. A2UW146FA1 INVERTER COMPRESSOR 8. Only for training and service purposes .20A CN-PRESS L N CN-PRESS CN-OIL/S WH RD LOW PRESS SWITCH BR GND-2 BK GND-1 BK RY-C/COMP BR SV OIL SEPERATOR GN/YL BL BR GN/YL BL T/B BR CN-COM L N BK RY-C/COMP BR BL RD CONSTANT OLP COMPRESSOR C R S T/B 1(L) 2(N) 1(L) 2(N) 3(A) 3(B) GND-1 GND-2 BR BR BL BL LEV A Power Supply LEV B LEV C LEV D LEV E LEV F LEV G LEV H BL BR BL BR CN-LEV-A LED-1 CN-LEV-B LED-2 CN-LEV-C LED-3 CN-LEV-D LED-4 CN-LEV-A LED-1 CN-LEV-B LED-2 CN-LEV-C LED-3 CN-LEV-C LED-4 1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 5(D) BRANCH DISTRIBUTOR-(A) CN-ROOM-A CN-ROOM-B CN-ROOM-C CN-ROOM-D L N S L N S L N S L N S L N S CN-PWR BRANCH DISTRIBUTOR-(B) CN-ROOM-A CN-ROOM-B CN-ROOM-C CN-ROOM-D L N S L N S L N S L N S L N S CN-PWR Only 8Rooms Model A B C D E F G H POWER SUPPLY A ROOM B ROOM C ROOM D ROOM TO INDOOR UNIT 3854A2 TO INDOOR UNIT TO INDOOR UNIT 3854A20354K Copyright ©2007 LG Electronics. A2UW146FA0.159 - LGE Internal Use Only . A3UW186FA1 INVERTER COMPRESSOR OUTDOOR WIRING DIAGRAM OUTDOOR WIRING DIAGRAM REACTOR RD BL YL REACTOR RD BL YL OR RD BL YL BK BK CN-FAN(A) BL BK BR YL OR FAN RD BL YL BK BK CN_FAN(A) CN-LEV2 CN-LEV1 U V W CN-COIL1 CN-COIL2 BL BK BR YL FAN LEV MAIN PCB LEV CN-4WAY 4WV 4WAY VALVE CN_LEV2 CN_LEV1 LEV U V W CN_COIL1 CN_COIL2 LEV LEV CN_4WAY CN_LEV3 4WV 4WAY VALVE MAIN PCB CN_TH2 CN_TH1 CN_TH3 CN-JIG-PC CN-CENTRAL CN-PRESS CN_JIG_PC CN_CENTRAL CN-WRITER CN-TH2 CN-TH3 CN_WRITER CN-TH1 (H/SINK) (AIR/PIPE) (DISP_I/SUG) CN_PRESS LOW PRESSURE SWITCH (H/SINK) (DISP-I/SUG) (AIR/PIPE) CN_COM L N CN-GND1 CN-GND2 L N GND_1 GND_2 BR BL WH BK BK BR BL BR BL BK BL BR WH BK BL BR 1(L) 2(N) 1(L) 2(N) 3(A) 3(B) 1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) GN/YL POWER SUPPLY A ROOM B ROOM TO INDOOR UNIT POWER SUPPLY A ROOM B ROOM C ROOM RD CN-COM 3854A203 TO INDOOR UNIT 3854A2035 9. Schematic Diagram Components Locations 1. Inc.C. Only for training and service purposes .160 - LGE Internal Use Only . Indoor Unit MAIN P. All right reserved.B ASM 1) Split Type • DC part • AC part Copyright ©2007 LG Electronics. 161 - LGE Internal Use Only . Only for training and service purposes . All right reserved.Schematic Diagram 2) Art Cool Type TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics. Inc. All right reserved. Inc. Only for training and service purposes .162 - R04K R02K R02A JP50 R06D IC01A JP14 IC02D R01P D02D IC01J IC03D Q01K R03K NF01J CN-POWER IC02M JP28 -H VB (B L) CN -S UC (W H) FUSE 250V/T2A JP55 C04J IC01K LGE Internal Use Only JP12 JP48 3 1 7 H) CN SMPS _S UC (W H) CN _H JP43 L1 C06D VB (B L) CN _T H1 CN _V FD (W H) JP11 JP46 45 1 10 15 .Schematic Diagram 3) Art Cool Deluxe Type • A/C MOTOR TOP VIEW C03J C04J CN_MOTOR CN_TH2 JP33 JP32 CN_L/R(BL) JP1 JP34 4 CN _U R01J CN_CC FUSE 250V/T2A /D (W CN_POWER JP28 D07D EARTH C05J JP29 C06J JP40 JP39 JP45 NF02J R05K C01J JP35 JP44 JP58 ZNR01J C04D D02K SD01D JP30 C01E NTC C01D C09D IC04D D01K NF01J ZNR02J PCB : 6870A90120C ASM : 6871A10111 JP47 CN_CON(BL) BZ01E JP42 JP41 R03J R02J D05D JP31 IC01D Q01V ~ D02D OSC01B IC01A ~ C05D ZD02D C02A IC1 JP49 TR01J JP56 JP38 JP51 JP52 IC01K IC02K BD01D IC02D IC01J JP19 + - JP50 Q01C IC03D BOTTOM VIEW JP32 CN-L/R(BL) R04H C03H R03H JP20 CN-MOTOR CN-CH2 JP1 JP5 JP34 IC01M IC04M JP27 CN -U /D (W H) JP33 C03J JP53 JP54 CN-CC R24G R23G R22G R21G R01J JP57 CN C01F JP43 D07D SMPS C05J EARTH C06J JP4 C N-T H1 L1 R02F R01F C06D JP29 C10D ZNR01J JP40 JP45 C07D CN JP3 JP39 -V F JP44 D(W JP58 H) JP35 C01J C04V R04V C04D NF02J D02K MICOM 50 SD01D C01E JP30 C03V R03V R02H R01H R05H JP16 C08D IC04D C01D C09D R03E Q02E NTC 40 ZNR02J JP48 JP46 JP47 JP25 JP9 R02L JP2 Q03E C01L R01E R02E Q01E C02H R06H C01H CN-CON(BL) R21H R23H R22H 55 TR01J R03J JP49 30 JP24 R04E JP26 R01B C02D D05D R02J R02G OR1H OR3H JP8 R01L IC01D JP18 R05V R06V JP15 20 JP31 25 JP41 R05D JP42 OR2H JP10 R01A C01A R05K Q01V JP17 BC01D C05D IC02K D01K R04J C01G R01G C01X JP19 Q02V R08D JP37 L01X L02X JP12 JP56 JP55 R03D R02D JP38 JP21 JP36 JP54 JP53 JP52 JP51 JP23 JP22 IC1 ZD02D Q01C R07D R04D JP13 JP7 JP6 C01K R01K Copyright ©2007 LG Electronics. 163 - LGE Internal Use Only .Schematic Diagram 3) Art Cool Deluxe Type • BLDC MOTOR TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics. Only for training and service purposes . Inc. All right reserved. All right reserved.Schematic Diagram 4) Duct Type • High static (BH/BG chassis) • Built in type (BP chassis) Copyright ©2007 LG Electronics. Inc. Only for training and service purposes .164 - LGE Internal Use Only . Schematic Diagram • Low static (BT. All right reserved.165 - LGE Internal Use Only . BT1 chassis) Copyright ©2007 LG Electronics. Inc. Only for training and service purposes . Only for training and service purposes .166 - LGE Internal Use Only . All right reserved. B2) TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics. Inc.Schematic Diagram • Low static (B1. Only for training and service purposes .167 - LGE Internal Use Only . Inc. All right reserved.Schematic Diagram 5) Casset Type • 1 way(TC Chasis) Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes .168 - LGE Internal Use Only . Inc.Schematic Diagram • 1 way(TC1 Chasis) TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics. Inc. Only for training and service purposes .Schematic Diagram • 4 way(TE/TF/TD chassis) B 58 • 4 way(TE1/TH chassis) TOP VIEW BOTOM VIEW Copyright ©2007 LG Electronics.169 - LGE Internal Use Only . All right reserved. Only for training and service purposes .Schematic Diagram 6) Convertible type • VE chassis AC part TOP VIEW BOTTOM VIEW DC part TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics.170 - LGE Internal Use Only . Inc. All right reserved. All right reserved. Inc.171 - LGE Internal Use Only . Only for training and service purposes .Schematic Diagram • VB chassis Copyright ©2007 LG Electronics. Inc. Only for training and service purposes . All right reserved.172 - LGE Internal Use Only .Schematic Diagram • VB chassis TOP VIEW BOTOM VIEW Copyright ©2007 LG Electronics. Only for training and service purposes .Schematic Diagram 2. Display ASSEMBLY 1) Split Type 2) Convertible Type VE chassis TOP VIEW PWB ASM:6871A20390 PCB:6870A90065K BOTTOM VIEW VB chassis 3) Art Cool Type TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics.173 - LGE Internal Use Only . All right reserved. Inc. 174 - LGE Internal Use Only TP4 TP3 TP2 TP2 TP7 TP8 TP4 TP6 TP5 TP3 TP1 TP1 C18 C8 C14 C15 C13 M42 R8 R7 M45 M44 1 C20 . Only for training and service purposes . All right reserved. SVM-GP1119AI P/N 3210018043 REV1 Q2 R9 R18 C19 Q1 R19 C7 R10 C9 R13 R3 R4 R6 R2 R17 D1 C21 R5 M43 BOTTOM VIEW 5) Art Cool Mirror TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics. Inc.Schematic Diagram 4) Art Cool Deluxe Type TOP VIEW SEJIN ELECTRON INC. Inc. Outdoor Unit 1) Component side Copyright ©2007 LG Electronics.175 - LGE Internal Use Only . All right reserved. Only for training and service purposes .Schematic Diagram 3. Schematic Diagram 2) Solder side Copyright ©2007 LG Electronics. Only for training and service purposes . Inc.176 - LGE Internal Use Only . All right reserved. Inc.177 - LGE Internal Use Only . All right reserved. Only for training and service purposes .Schematic Diagram 3) Central control PCB) 1) Top View 2) Bottom View Copyright ©2007 LG Electronics. SUB P. Inc.B ASSEMBLY 1) Art Cool Type TOP VIEW BOTTOM VIEW Copyright ©2007 LG Electronics.Schematic Diagram 4. Only for training and service purposes . All right reserved.178 - LGE Internal Use Only .W. 179 - Refrigerant Flow Cooling Heating LGE Internal Use Only Field Piping Gas Field Piping Liquid . A2UW186FA0. A2UW166FA0/1. Only for training and service purposes . All right reserved. A3UW186FA0/1 Exchanger Heat OUTDOOR UNIT Th4 Reversing Valve Compressor Th1 Th3 LEV-C LEV-B Room C Room B LEV-A Room A Drier Th2 Th3 Low Pressure S/W 3 rooms model Header Accumulator 3 rooms model Room C Room B Room A Copyright ©2007 LG Electronics.Troubleshooting Guide Troubleshooting Guide Refrigeration Cycle Diagram 1. A2UW146FA0/1/2. Inc. Only for training and service purposes Check Valve(2) Accumulator Heat Exchanger Constant Compressor 4 room model LEV-D Inverter Compressor Th4 . A3UW246FA0.4 room model Room D Room C Room B Room A Header Reversing Valve OUTDOOR UNIT Troubleshooting Guide Field Piping Gas Check Valve(1) Oil Seperator Th2 Th1 Th5 2. A4UW246FA0 Room D Room C Room B Room A LEV-A LEV-B LEV-C Th3 Low Pressure S/W Field Piping Liquid Valve(1) Solenoid Cooling LGE Internal Use Only Heating Valve(2) Solenoid Drier Copyright ©2007 LG Electronics. All right reserved.180 - Refrigerant Flow . Inc. Inc.181 - Room D Refrigerant Flow Cooling . A4UW306FA0 Room C Field Piping Gas Room B Th5 Header Check Valve(2) Oil Seperator Th2 Th1 Heat Exchanger Check Valve(1) Field Piping LEV-B LEV-A Room C LEV-C Low Pressure S/W Liquid Room B Room A Valve(1) Solenoid Th3 Troubleshooting Guide LGE Internal Use Only Heating Valve(2) Solenoid Drier Copyright ©2007 LG Electronics. All right reserved.OUTDOOR UNIT Reversing Valve Room D 3. Only for training and service purposes Accumulator Constant Compressor LEV-D Inverter Compressor Th4 Room A . 88) LowPressure Pressure Low S/W S/W Solenoid Valve(1) Copyright ©2007 LG Electronics. A4UW306FA1 Troubleshooting Guide Th5 Constant Compressor Inverter Compressor Th3 Field Piping Gas(Ø 15. All right reserved. Inc. Only for training and service purposes Check Check Valve(2 Valve(2) ) Accumulator Th2 Oil Seperator Check Check Valve(1 Valve(1) ) Oil Seperator Th1 Heat Exchanger Th4 Field Piping Liquid (Ø 6.OUTDOOR UNIT Refrigerant Flow Cooling Heating Reversing Valve 4.35) Drier Receiver .182 - LGE Internal Use Only . Th4 Field Piping Liquid (Ø 9.52) Drier Receiver Solenoid Valve(1) Copyright ©2007 LG Electronics. A6UW406FA0 Th5 Constant Compressor Inverter Compressor Th3 Field Piping Gas(Ø 19.183 - Troubleshooting Guide LGE Internal Use Only .OUTDOOR UNIT Refrigerant Flow Cooling Heating Reversing Valve 5.05) LowPressure Pressure Low S/W S/W L. All right reserved. Inc. Only for training and service purposes Check Check Valve(2 Valve(2) ) Accumulator Th2 Oil Seperator Check Check Valve(1 Valve(1) ) Oil Seperator Th1 Heat Exchanger .E.V. E. Drier Receiver .OUTDOOR UNIT Reversing Valve Refrigerant Flow Troubleshooting Guide Cooling Heating 6. A8UW566FA0 Constant Compressor 2 Constant Compressor 1 Low Pressure S/W Inverter Compressor Th4 Solenoid Valve(1) Copyright ©2007 LG Electronics.184 - Field Piping Gas(Ø 19. Only for training and service purposes Th6 Check Valve(3) Check Valve(2) Oil Seperator Heat Exchanger Check Valve(1) Accumulator Th3 Th2 Th1 Th5 L. Inc.52) . A7UW486FA0.V.05) LGE Internal Use Only Field Piping Liquid (Ø 9. All right reserved. 52 or Ø12.52 or Ø12. Only for training and service purposes .7) B Liquid(Ø9.52) Piping ( Ø 15.52 or Ø12.35) B Liquid(Ø6.35) A Liquid(Ø6.7) A Liquid(Ø9.Troubleshooting Guide 7.7) LEV-B LEV-A D Liquid(Ø6. All right reserved. BD Unit Refrigerant Flow Cooling Heating Main Liquid Main Gas Piping ( Ø 9.35) C Liquid(Ø6. Inc.52) C Liquid(Ø9.35) [Indoor Unit] Copyright ©2007 LG Electronics.88) D Liquid(Ø9.185 - LEV-D LEV-C LGE Internal Use Only Outdoor Unit . Pipe Low Heatsoml Th error (Open/Short) INV TPS LED 1 (Red) 2times 2times 2times 2times 2times 2times 2times 2times 3times 3times 4times 4times 4times 4times 4times 4times 5times 5times 5times 6times 6times 6times 6times 6times LED 2 (Green) 1time 2times 3times 4times 5times 6times 7times 8times 2times 3times O 1time 4times 5times 6times 7times 1time 2times 3times O 1time 2times 3times 5times Indoor Status OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ❈ CH52 : Only A2UW146FA0(FM17AH UL0) Copyright ©2007 LG Electronics. L_P/Heater Sink Low voltage / Over voltage DC Comp Position Error PSC Fault Error DC Link High Volt D-Pipe High (INV) D-Pipe High (Normal) CT Sensor (Open/Short) INV. Pipe Th Error(Open/Short) Suction Pipe Error(Open/Short) Const D-pipe Th Error(Open/Short) Capacity over Signal error(INV Board ↔ Main Board) Signal error (Indoor ↔ Outdoor) EEPROM Check Sum Error Cond. • After error occurrence. • Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table. Indoor Error Error code 00 01 02 03 04 05 06 07 Description No Error Indoor Room themistor error Indoor in-piping sensor error Remote controller error Drain Pump error Communcation error between in and out Indoor Out-Piping sensor error Differnt mode operation INV TPS LED 1 (Red) LED 2 (Green) 1time 2times 3times 4times 5times 6times 7times Indoor Status ON OFF OFF OFF OFF OFF OFF OFF Outdoor Error Error Code 21 22 23 24 25 26 27 28 32 33 40 41 44 45 46 47 51 52 53 60 61 62 63 65 Description DC Peak (IPM Fault) CT 2(Max CT) DC Link Low Volt. Inc. • If more than two troubles occur simultaneously.186 - LGE Internal Use Only . All right reserved. error LED is also released simultaneously. Only for training and service purposes . Pipe High Heatsink High Cond.Troubleshooting Guide Self-diagnosis Function I Error Indicator • The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble. be sure to turn off the power and then turn on. primarily the highest trouble fo error code is expressed. • Having or not of error code is different from Model. D-PipeTh Error(Open/Short) Outdoor air Th Error(Open/Short) Cond. • To operate again on the occurrence of error code. if error is released. 2 Copyright ©2007 LG Electronics. difference Current : approx. Suction pressure (Compared with the normal value) Temperature (Compared with the normal value) High Higher Normal Excessive amount of refrigerant Insufficient amount of refrigerant(Leakage) Clogging High pressure does not quickly rise at the beginning of operation. Temp. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with putty. Check temperature difference between intake and discharge air. Check temperature and pressure of refrigeration cycle.Troubleshooting Guide Cycle Troubleshooting Guide Trouble analysis 1. When the room air humidity is relatively lower temperature difference is larger. Check refrigeration cycle. All right reserved. 2. Only for training and service purposes . 2. and operating current. Inc. difference : over 8°C Normal Notice: Temperature difference between intake and discharge air depends on room air humidity. 8°C : less than 80% of rated current Refrigerant leakage Clog of refrigeration cycle Defective compressor Temp. When the room air humidity is relatively higher. Difference Temp. Lower Higher Notice: 1.5~6.0 kg/cm G at normal condition. 0°C : less than 80% of rated current All amount of refrigerant leaked out. difference Current Operating Current Temp. Current is low. difference Current : less than 8°C : near the rated current Excessive amount of refrigerant : approx.187 - LGE Internal Use Only . temperature difference is smaller. Temp. The suction pressure is usually 4. Cause of Trouble Defective compressor Description Current is low. Noise Filter. • The voltage of main power. 4) Replace IC02D. Ass'y Procedure 1) The input voltage of power transformer. Ass'y (Fuse. 50Hz). • Check CN-DISP1 The operation check of the P. 2) The output voltage of power transformer. the operating condition of Micom is O. • The connecting method of Indoor/Outdoor connecting cable (each color) • The P. Trouble 1 The Product doesn’t operate at all. Does "Beeping" sound is made from the indoor unit? NO Check the voltage of power(AC220V/AC240V. A3UW186FA0/1 ❇ Refer to electronic contorol device drawing & schematic diagram. Inc. etc.B. A2UW146FA0/1/2. A2UW186FA0. Turn on the main power again. All right reserved. A2UW166FA0/1. IC02D.) YES • Primarily. Only for training and service purposes .188 - LGE Internal Use Only .C.5V↑ Remedy 1) Replace power transfomer.K. IC01D. Copyright ©2007 LG Electronics. Turn off the main power and wait until LED on outdoor PCB is off.B.Troubleshooting Guide Electronic Parts Troubleshooting Guide 1. 2) Replace power transfomer. 3) IC01D(7812) 4) IC02D(7805) 5) IC01A(KIA7036) Specification 1) AC230V ± 30V : Check the rated voltage 2) 14V ± 3V 3) DC12V 4) DC5V 5) The voltage of micom pin 29 : DC4. • The voltage applied to the unit. Power Transformer. 3) Replace IC01D.W. 5) Replace IC01A. Check the contact of CN-DISP 1 connector When the detect switch (double key) inside the remote controller door is fault.➆ : DC +5V Check the Display PWB Ass'y • Check receiver ass'y Copyright ©2007 LG Electronics. (When operated in the Sleeping Mode. Caused by other parts except the remote controller When the mark ( ) is displayed in LCD screen. At this point the wind speed is not controlled by the remote controller. Only for training and service purposes . replace battery.189 - LGE Internal Use Only .Troubleshooting Guide Trouble 2 Product doesn't operate with the remote controller. While the compressor has been stopped. the compressor does not operate owing to the delaying function for 3 minutes after stopped. All right reserved. the wind speed is set to the low speed as force. Check DISP PWB Ass'y -Voltage between CN1 ➀ . Inc. Turn on main power.) Caused by the remote controller. it is impossible to operate temperature regulating(L / M) and wind speed selecting. When the compressor stopped Indoor Fan is driven by a low speed. Compressor/Outdoor fan is stopped. Only for training and service purposes . • Check the related circuit of relay in Outdoor PCB Ass'y. Check the sensor for Indoor temperature is attatched as close as to be effected by the themperature of Heat Exchange (EVA. When in air circulation mode. All right reserved. Copyright ©2007 LG Electronics. Inc. R04H(6. • Check the related circuit of R02H(12. C02H(102). • Check the voltage between brown and blue cable of terminal to connect the Outdoor (About AC220V / 240V). Check the Relay(RY-PWR. RY-START) for driving Compressor. R01H(1K). ON DC 5V DC 1V↓ Comp. 10) and GND Comp. Check the open or short of connecting wires between Indoor and Outdoor. OFF DC 0V DC 12V Turn off main power.1K).) When the sensor circuit for Indoor temperature and connector are in bad connection or are not engaged.Troubleshooting Guide Trouble 3 The Compressor/Outdoor Fan are don't operate Turn on the main power.190 - LGE Internal Use Only . Operate Cooling Mode by setting the disired temperature of the remote controller is less than one of the Indoor temperature by 1°C at least. compressor/outdoor fan is stopped. . R03H(1K). Check the electrical wiring diagram of Outdoor side.2K). • Check the Indoor temperature sensor is disconnected or not (about 10K at 25°C). Micom(pin No. Check Point Between Micom(No. ). 19) and GND Between IC01M(No. C01H(102). 38 of micom and the part for driving SSR. T2A). About AC 160V over About AC 50V over SSR is not damaged Check SSR Copyright ©2007 LG Electronics. Check the related circuit of indoor Fan Motor. • Check the SSR.(Q01M) • Check the related pattern. . . • The pin No. Check the Fan Motor. Check the connection of CN-FAN. (the Indoor Fan Motor is connected) The voltage of Pin No 1(orange) and 3(black) of CN-FAN. All right reserved.191 - LGE Internal Use Only . Only for training and service purposes . Turn off main power.SSR short: Indoor Fan Motor always operates in case of ON or OFF.Troubleshooting Guide Trouble 4 When indoor Fan does not operate. Inc. Check the Fuse(AC250V.SSR Open: Indoor Fan Motor never operate. Turn on the main power Check the SSR high speed operation by remote control. CN0L/R and GND. 6 and 7 of IC01M . • If the regular torque is detected when rotating the vertical louver with hands ⇒ Normal • Check the connecting condition of CN-U/D or CN0L/R Connector • Check the soldering condition(on PCB) of CN-U/D or CN0L/R Connector Check the operating circuit of the vertical louver • Confirm that there is DC +12V between pin ➀ of CN-U/D.Between 5 . 5 .Between 4 .Between 17 . 2 . 19 and 20 of MICOM .Between 1 . .192 - LGE Internal Use Only . • Confirm that the vertical louver is normally geared with the shaft of Stepping Motor. 3 and 4 of MICOM . • Confirm the assembly condition that are catching and interfering parts in the link of the vertical louver Copyright ©2007 LG Electronics. 18 . Only for training and service purposes . Inc. All right reserved. 7 and 8 of IC01M If there are no problems after above checks. 6 . • Confirm that there is a soldering short at following terminals.Troubleshooting Guide Trouble 5 When the louver does not operate. if error is released. and LED of outdoor unit control board. • Error mark is displayed on display window of indoor units and wired-remote controller. 1 digit I Indoor Error Error code 01 02 03 04 05 06 07 Contents Air sensor (open/short) Inlet pipe sensor 10 digit Case of error Open / Short Open / Short Communication Poorly Float switch Open Communication Poorly Open / Short Different operation mode Indoor Status Off Off Off Off Off Off Off Communication(Indoor ↔ Wired R/Control) Drain pump/ Float switch Communication(Indoor ↔ Outdoor) Outlet pipe sensor Different operation mode Copyright ©2007 LG Electronics. • After error occurs. error LED is also released simultaneously.Troubleshooting Guide General Information I Error Indicator (Indoor) • The function is to self-diagnosis air conditioner and express the troubles if there is any trouble. Only for training and service purposes .193 - LGE Internal Use Only . Inc. lower number of error code is first displayed. • If more than two troubles occur simultaneously. All right reserved. Current) DC Link Low Volt. High (INV) Discharge Pipe Temp.) LED01G LED02G (Green) (Red) 2 times 2 times 2 times 2 times 2 times 2 times 2 times 2 times 3 times 3 times 1 time 2 times 3 times 4 times 5 times 6 times 7 times 8 times 2 times 3 times Off Off Off Case of error Compressor malfunction.Troubleshooting Guide I Error Indicator (Outdoor) Outdoor Error Ex) Error 21 (DC Peack) 2 Times 2 Times 2 Times LED01G (RED) 1 Sec. Outdoor Status Off Off Off Off Off Off Off Off Off Off Copyright ©2007 LG Electronics. 2 Sec. High (Cons. Only for training and service purposes . DC Compressor Position PSC Fault DC Link High Volt Discharge Pipe Temp. 1 Time LED02G (GREEN) 2 Sec.194 - LGE Internal Use Only . Is 140V Low / High press switch OPEN Abnormal AC volt. All right reserved. 1 Time 1 Sec. Low / High press AC Low / AC High Volt. 1 Time 1 Sec.IPM Fault Current is 14A DC Link volt. Error code 21 22 23 24 25 26 27 28 32 33 Contents IPM Fault (Compressor Over current) CT 2(Max. Input. Inc. Pipe sensor temp. Temp. Pipe sensor (open/ short) Suction pipe sensor (open/ short) D-pipe sensor Cons. (open/ short) Air sensor (open/ short) Cond. high Heat sink temp. high Open / Short Copyright ©2007 LG Electronics.Troubleshooting Guide I Error Indicator (Outdoor) Outdoor Error Error code 40 41 44 45 46 47 51 53 60 61 62 65 CT Circuit Contents LED01G LED02G (Green) (Red) 4 times 4 times 4 times 4 times 4 times 4 times 5 times 1 time 4 times 5 times 6 times 7 times 1 times 3 times Case of error CT Circuit malfunction Open / Short Open / Short Open / Short Open / Short Open / Short Over combination Communication Poorly Check sum mismatching Outdoor Status Off Off Off Off Off Off Off Off Off Off Off Off D-pipe sensor INV. (open/ short) Over capacity Communication (Indoor EEPROM check sum Cond. Only for training and service purposes . high Heat sink sensor (open/ short) Outdoor) 5 times 6 times 6 times 6 times 6 times 1 time 2 times 5 times Cond.195 - LGE Internal Use Only . high Heat sink sensor temp. All right reserved. Inc. Plug the sensor on Indoor unit PCB and Power ON. 7. If the voltage of the sensor is 2. Copyright ©2007 LG Electronics. then sensor is normal. Estimate the resistance of each sensor. Inc. If the resistance of the sensor is 0 or 5Vdc.5Vdc at 25°C. Unplug the sensor on Indoor unit PCB. ¡ Repair or Change the PCB. 6. ¡ Change the sensor. All right reserved. CH02.5Vdc / at 25°C (plugged) Indoor air sensor 02 Indoor inlet pipe sensor 06 Indoor outlet pipe sensor 10kΩ Ω 2.196 - LGE Internal Use Only . 2. Only for training and service purposes . If the resistance of the sensor is 10KΩ/ 5KΩ at 25°C. then sensor is abnormal. then sensor is abnormal. 8. 4. 5.5Vdc / at 25°C (plugged) Normal resistor : 5KΩ/ at 25°C (Unplugged) Normal voltage : 2.5Vdc / at 25°C (plugged) Normal resistor : 5KΩ/ at 25°C (Unplugged) Normal voltage : 2. then sensor is normal. 3. If the resistance of the sensor is 0 KΩ or ∞. Estimate the voltage of each sensor.Troubleshooting Guide 1) Troubleshooting CH01. CH06 Display code 01 Title Cause of error • Open / Short • Soldered poorly • Internal circuit error • Open / Short • Soldered poorly • Internal circuit error • Open / Short • Soldered poorly • Internal circuit error Check point & Normal condition Normal resistor : 10KΩ/ at 25°C (Unplugged) Normal voltage : 2.5Vdc V Check the resistance Check the voltage Check Point 1. Inc.197 - LGE Internal Use Only . (Open / Short) ¡ Repair the connection 2. 4.Troubleshooting Guide 2) Troubleshooting CH03 Display code 03 Title Communication Wired R/C Cause of error • Open / Short • Wrong connection Check point & Normal condition • Connection of wire • Main PCB Volt. Of main PCB power source. Check the Volt. (Soldered poorly) ¡ Repair or Change the PCB. DC12V • Noise interference Wired R/C 12V S GND 12V Indoor Unit S GND CN-REMO 12Vdc V 12Vdc V Check the Volt. Check the soldering state of connector. 3. Only for training and service purposes . All right reserved. (Noise interference) ¡ Adjust the state of installation Copyright ©2007 LG Electronics. Check the installation of wired remote controller. DC 5V) ¡ Repair or Change the main PCB. (DC 12V. Check Point 1. Check the wire connection. Check the volt. Check the wire connection. Copyright ©2007 LG Electronics. All right reserved.Troubleshooting Guide 3) Troubleshooting CH04 Display code Title Cause of error Check point & Normal condition • The connection of wire(Drain pump/ Float switch) • Drain pump power input. Of Drain pump power supply. Inc. (220V) • Drain tube installation. (Open. • Indoor unit installation. Normal : short) ¡ Check the float switch. (Normal : short) CN Float CN-D/PUMP CN-Float 0Ω Ω Check the resistance Check Point 1. Check the resistance of float switch (Abnormal : Open. Check the level of water 4. Only for training and service purposes . (Inclination) 04 Drain pump / Float switch • Float switch Open. 2. 3. Check the volt.198 - LGE Internal Use Only . (AC 230V) ¡ Repair or Change the main PCB. Soldered poorly) ¡ Repair the connection or change the PCB. “Neutral” 3. All right reserved. (Normal : Over 2MΩ) 4. CH53 Display code Title Cause of error Check point & Normal condition • Power input AC 220V. * CH05 is displayed at indoor unit. • The GND1. • The connecting wires are misconnected. (Outdoor. GND2. and main GND. 6. Check the resistance between communication line and GND.2 is not connected at main GND. Check the communication wires are correctly connected. ¡ Adjust the connection of wire ¡ Confirm the wire of “Live”. • Transmission circuit of outdoor PCB is abnormal.199 - LGE Internal Use Only . • The communication line is shorted at GND. (Outdoor. 04 / 53 Communication (Indoor ¡ Outdoor) • Communication poorly Check Point 1. CH53 is displayed at outdoor unit. Copyright ©2007 LG Electronics. Check the connector for communication is correctly connected. Inc. ¡ Check the another indoor unit. Indoor unit) 2. Check the connection of GND1. outdoor PCB is no problem. • Transmission circuit of indoor PCB is abnormal. Indoor) • The connector for transmission is disconnected. If one indoor unit is operated normally. 5. Only for training and service purposes .Troubleshooting Guide 4) Troubleshooting CH05. Check the input power AC230V. Check the wire connection.64 0. (U. Copyright ©2007 LG Electronics.200 - LGE Internal Use Only .V.Overcharging of refrigerant .8Ω(Cons. ¡ Check the trace of water.W) 2. 4.V. 0. 2MΩ 2MΩ 2MΩ 2MΩ 2MΩ 2MΩ Check Point 1.8 0. comp. Check the IPM circuit.) ¡ No difference at each terminal. 5. Check the insulation from water at IPM part.V.64 0. (Refrigerant.W • Over load condition .The abnormal connection of U. 0. Pipe length. …) ¡ Adjust the load condition 3.Comp lock . • Poor insulation of compressor 21 DC Peak • Instant over current • Over Rated current • Poor insulation of IPM Comp U Ω V W Resistance(Ω) at 20°C Terminal U-V V-W W-U Copper pipe Inverter Constant comp.W phase . Check the load condition. ¡ Normal : Over 2MΩ. 6.64 0.8 Comp Resistance(Ω) at 20°C Ω Terminal U-GND V-GND W-GND Inverter Constant comp. Check the resistance of compressor. ¡ Normal : 0. All right reserved. Only for training and service purposes . Inc.Troubleshooting Guide 5) Troubleshooting CH21 Display code Title Cause of error Check point & Normal condition • An instant over current in the U. comp.65Ω(INV).Pipe length. Check the electricity leakage of the compressor.8 0. C/T Over current (14A ) 22 C/T Internal circuit Initial current error V Check Point 1. Check the current.0Vdc(25A) . (Open / Short) The voltage of “C01N” Is 4. 5. pipe length. Check the install condition. 2. Diode. (C/T. Check the power source. blocked. Check the fan operation is right. Only for training and service purposes . 3. 4. Max.Troubleshooting Guide 6) Troubleshooting CH22 Display code 21 Title Cause of error Check point & Normal condition Malfunction of compressor Blocking of pipe Low voltage input Refrigerant. Inc. Check the internal circuit.201 - LGE Internal Use Only . Resistor) + + - + Copyright ©2007 LG Electronics. All right reserved. … Malfunction of current detection circuit. 2. Only for training and service purposes . CH28 Display code 23 Title DC Link Low voltage. is 420Vdc . • Check the components. Check Point 1. Inc. • Check the power source.202 - LGE Internal Use Only . 28 DC Link High voltage • DC link volt. All right reserved. • Check the power source. Cause of error Check point & Normal condition • DC link volt. is 140Vdc . Reactor. • Check the components.Troubleshooting Guide 7) Troubleshooting CH23. Check the power source. PSC Parts ) V Copyright ©2007 LG Electronics. Check the components (B/Diode. All right reserved. 2. Resistance) Copyright ©2007 LG Electronics. • CH 25 1. Check the install condition for over load. B/Diode. CH25 Display code 24 Title Cause of error Check point & Normal condition Press S/W Open • Low / High press S/W open. Only for training and service purposes . 3. Check the connection of “CN_PRESS” 2.203 - LGE Internal Use Only . • Check the components. TRANS1 50Hz. Check the components (Trans1. Check the SVC V/V open. DC12V CN PRESS CN TRNAS1 Check Point • CH 24 1. 4. Diode. Inc. • Check the components. • Check the connection of “CN_Press”.Troubleshooting Guide 8) Troubleshooting CH24. • Check the power source. Check the power source. 25 Input voltage • Abnormal Input voltage (140Vac . Check the leakage of refrigerant. 300Vac . Check the connection of “U.204 - LGE Internal Use Only .W” 2. BD02S) Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes . Inc.V.V.Troubleshooting Guide 9) Troubleshooting CH26. Check the components (IGBT. Check the component of “IGBT” 2. NF1. detection parts. • Compressor position detect error 27 PSC Fault • Over current at “IGBT” • Check the component of “IGBT” . R04S. E C B C B E Check Point • CH 26 1.W” • Malfunction of compressor • Check the component of “IPM”. Check the compressor. (same with CH21) • CH 27 1. 3. Check the insulation of IPM part. • Check the components. CH27 Display code 26 Title DC Compressor Position Cause of error Check point & Normal condition • Check the connection of comp wire “U. Only for training and service purposes . Check the install condition for over load.) temp. Check the constant compressor. high D-Pipe temp. 3.205 - LGE Internal Use Only . • Check the SVC V/V open. 2. • Check the install condition for over load. (same with CH21) Copyright ©2007 LG Electronics. Toff(105) °C T2(95) °C T1(90) °C COMP Frequency Normal (Hz) LEV Openness (Pulse) Normal Normal Normal OFF OFF Control Check Point • CH 32 1. • CH 33 1. • Check the install condition for over load. high 33 • Discharge sensor (Cons. • Check the discharge pipe sensor for Cons. Check the install condition for over load. Check the leakage of refrigerant. • Check the SVC V/V open. Check the leakage of refrigerant. All right reserved. 2. • Discharge sensor (Inverter) temp. • Check the leakage of refrigerant.Troubleshooting Guide 10) Troubleshooting CH32. 4. high (105°C ) Cause of error Check point & Normal condition • Check the discharge pipe sensor for INV. CH33 Display code 32 Title D-pipe (Inverter) temp. Check the SVC V/V open. 3. high (105°C ) D-pipe (Constant) temp. • Check the leakage of refrigerant. Inc. Check the SVC V/V open. 5Vdc / at 25°C (plugged) Check Point 1.206 - LGE Internal Use Only . CH65 Display code 41 Title Cause of error • Open / Short • Soldered poorly • Internal circuit error • Open / Short • Soldered poorly • Internal circuit error • Open / Short • Soldered poorly • Internal circuit error • Open / Short • Soldered poorly • Internal circuit error • Open / Short • Soldered poorly • Internal circuit error • Open / Short • Soldered poorly • Internal circuit error Check point & Normal condition • Normal resistor : 200KΩ / at 25°C (Unplugged) • Normal voltage : 4. then sensor is abnormal.5Vdc / at 25°C (plugged) D-pipe sensor (Inverter) 44 Air sensor • Normal resistor : 10KΩ / at 25°C (Unplugged) • Normal voltage : 2.(Unplugged) 2.5Vdc / at 25°C (plugged) 46 Suction Pipe sensor • Normal resistor : 5KΩ / at 25°C (Unplugged) • Normal voltage : 2. Estimate the voltage of each sensor. Only for training and service purposes . CH44. If the resistance of the sensor is 0 kΩ or ∞. Inc. Ω If the voltage of the sensor is 0 V or 5Vdc.Troubleshooting Guide 11) Troubleshooting CH41. All right reserved. CH47. Copyright ©2007 LG Electronics.5Vdc / at 25°C (plugged) 45 Condenser Pipe sensor • Normal resistor : 5KΩ / at 25°C (Unplugged) • Normal voltage : 2.(Plugged) 3. CH45.5Vdc / at 25°C (plugged) 47 D-pipe sensor (Constant) • Normal resistor : 200KΩ / at 25°C (Unplugged) • Normal voltage : 4. then sensor is abnormal. CH46. Estimate the resistance of each sensor.5Vdc / at 25°C (plugged) 65 Heat sink sensor • Normal resistor : 10KΩ / at 25°C (Unplugged) • Normal voltage : 2. Model A2UW146FA0 A2UW146FA1 A2UW146FA2 A2UW166FA0 A2UW166FA1 A2UW186FA0 A3UW186FA0 A3UW246FA0 A4UW246FA0 A4UW306FA0 A6UW406FA0 Gross max. 60 EEPROM Check sum • Check sum error • Check the PCB ASM P/No. • Check the combination table. All right reserved.207 - LGE Internal Use Only . Check the indoor unit capacity. Check the poor soldering Copyright ©2007 LG Electronics. capacity 21k Max. Check the insertion condition of EEPROM. Inc. single indoor unit capacity 12k 24k 30k 33k 39k 52k 12K 18k 24K 24K 24K Check Point • CH 51 1. • CH 60 1. Only for training and service purposes .Troubleshooting Guide 12) Troubleshooting CH51. 2. • Check the poor soldering. CH60 Display code 51 Title Cause of error Check point & Normal condition Over capacity • Over capacity Combination • Check the indoor unit capacity. 62 Heat sink sensor temp. Toff °C T2 °C T1 °C COMP Frequency Normal (Hz) Normal OFF Normal Check Point • CH 61 1. • Check the sensor of heat sink.(85°C) Check point & Normal condition • Check the load condition. Pipe length.(65°C) • Heat sink sensor detected high temp. Only for training and service purposes .Troubleshooting Guide 13) Troubleshooting CH61. CH62 Display code 61 Title Condenser pipe sensor temp. (Refrigerant. is very high. Inc. Check the install condition for over load.208 - LGE Internal Use Only . 2. Heat Sink temp. Check the Outdoor temp. Check the fan is locked. Blocked. high Cause of error • Condenser pipe sensor detected high temp. • Check the sensor of Condenser pipe sensor. …) • CH 62 1. high • Check the fan is locked. Copyright ©2007 LG Electronics. All right reserved. Air purging (Installation) Open Open (counter-clockwise) (push-pin or with vacuum pump) Open (with valve cap) Closed (clockwise) Closed (with cap) Closed (with cap) Operation Open (with valve cap) Open (counter-clockwise) 2. All right reserved.(3-way) Valve (3-way) Valve 3-way Valve (Liguid Side) 3-way Valve (Gas Side) Valve cap Open position Closed position Pin To piping connection Valve cap Open position Closed position Pin To piping connection Service Service port cap port Service Service port cap port To outdoor unit To outdoor unit Works Shipping Shaft position Closed (with valve cap) Service port Closed (with cap) Shaft position Closed (with valve cap) Closed (clockwise) Service port Closed (with cap) Open (push-pin or with vacuum pump) Closed (with cap) Open (connected manifold gauge) Open (connected manifold gauge) Open (with charging cylinder) Open (connected manifold gauge) Open (connected manifold gauge) 1. Gas charging (Servicing) Open Open 5. Pressure check (Servicing) Open Open (connected manifold gauge) Open (connected manifold gauge) Open 6. Pumping down (Transfering) 3.209 - LGE Internal Use Only . Gas releasing (Servicing) Open Open Copyright ©2007 LG Electronics. Inc. Evacuation (Servicing) Open Open (connected manifold gauge) Closed (with cap) Open 4. Only for training and service purposes . Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 1kg/cm g. . Only for training and service purposes 6.(3-way) Valve (1) Pumping down Indoor unit Liquid side 2-Way valve Close Outdoor unit Gas side 3-Way valve Open Indoor unit Liquid side 2-Way valve Close Gas side 3-Way valve manifold gauge Open Lowhandle (CLOSE) Hi.handle (CLOSE) • Procedure 1. 5. Air purging of the charge hose. Confirm that both the gas side and liquid side valves are set to the open position. .5kg.Be sure to check for gas leakage.Open the Low-handle valve on the gauge slightly to air purge from the hose.Use torque wrench to tighten the service port nut to a torque of 1. 2 7. .(4.Connect the hose of the gauge with the push pin to the service port.2kg. . Disconnect the charge set. Copyright ©2007 LG Electronics. Operate the unit for 10 to 15 minutes. Set the liquid side valve to the closed position. . Stop operation and wait for 3 minutes.210 - LGE Internal Use Only . . Immediately set the gas side valve to the closed position.m. and mount the liquid side and gas side valve caps and the service port nut.Do this quickly so that the gauge ends up indicating 1kg/ g.m/5. . • Be sure to short pressure S/W. 4.Remove the valve stem caps and confirm that the valve stems are in the raised position. then connect the manifold gauge to the service port of the gas side valve. Inc.Be sure to use a hexagonal wrench to operate the valve stems.8kg. 2. 3. otherwise Low pressure S/W detect low pressure skete and stops the compressor. 8. All right reserved.m) . Inc. . If the vacuum pump oil becomes dirty or depleted. Close the Low handle of the gauge turn off the vacuum pump. 6.Confirm that the gauge needle has moved toward-76 cmHg (vacuum of 4 mmHg or less). 7.211 - LGE Internal Use Only . 5. Connect the service port of the gas side valve to the low side of the gauge. Only for training and service purposes . 3. Connect the vaccum pump to the center hose of the manifold gauge.(3-way) Valve (2) Evacuation (All amount of refrigerant leaked) Indoor unit Liquid side 2-Way valve Open Outdoor unit Gas side 3-Way valve Open Indoor unit Liquid side 2-Way valve Open Gas side 3-Way valve manifold gauge Vacuum pump Lowhandle (OPEN) Hi. Confirm that both the liguid side valve and gas side valve are set to the opened position.replenish as needed. and confirm that the gauge needle does not move(approximately 5 minutes after turning off the vacuum pump). . Disconnect the charge hose from the vacuum pump. Copyright ©2007 LG Electronics.handle (OPEN) Open • Procedure 1. Evacuation for approximately one hour.Vacuum pump oil. 2. Mount the valve caps and the service port caps. All right reserved. 4. absolutely do not attempt to charge with larger amounts of liquid refrigerant while operating the air conditioner. Because you are charging with liquid refrigerant from the gas side. Mount the valve stem nuts and the service port nut. also use a scale and reverse the cylinder so that the system can be charged with liquid. Open the low handle on the gauge and charge the system with liquid refrigerant. This is different from previous procedures.(3-way) Valve (3) Gas Charging (After Evacuation) Indoor unit Liquid side 2-Way valve Open Outdoor unit Gas side 3-Way valve Open Indoor unit Liquid side 2-Way valve Open Gas side 3-Way valve Charging cylinder manifold gauge Open Low-handle Check valve (OPEN) Hi. 3.If the system can not be charged with the specified amount of refrigerant. All right reserved. The procedure is the same if using a gas cylinder. .m.handle (OPEN) • Procedure 1.Use torque wrench to tighten the service port nut to a torque of 1. .8 kg. . .2kg.Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder. (Be careful of the liquid refrigerant).m/5.Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air. Purge the air from the charge hose.(4.5kg. Immediately disconnect the charge hose from the gas side valve's service port.m. one time is not sufficient. . it can be charged with a little at a time (approximately 150g each time) while operating the air conditioner in the cooling cycle.If you are using a gas cylinder. Copyright ©2007 LG Electronics.) . 5.Stopping partway will allow the gas to be discharged. Inc.If the system has been charged with liquid refrigerant while operating the air conditioner turn off the air conditioner before disconnecting the hose. wait approximately 1 minute and then repeat the procedure(pumping down-pin). . . 2. Connect the gauge to the charging cylinder.Be sure to check for gas leakage. however. Only for training and service purposes . 4.212 - LGE Internal Use Only . Exploded View Exploded View Indoor Unit SQ/SR chassis 135316 135314 152313 152302 131410 359011 733010 342800 159830 354210 147581 268711A 352115 352116 35211B 263230B 352150 146811 346810 135516 263230A 135311 266090 267110 249951 268711B 268711C W0CZZ Copyright ©2007 LG Electronics. All right reserved.213 - LGE Internal Use Only . Inc. Only for training and service purposes . 214 - LGE Internal Use Only .Exploded View ST chassis 135316 267110 135314 152313 152302 131410 359011 733010 342800 159830 135311 W51620 147581A 147581B 268711A 352115 352116 35211B 263230B 352150 146811 346810 135516 263230A 268711B 249951 266090 268711C W0CZZ Copyright ©2007 LG Electronics. Only for training and service purposes . Inc. All right reserved. 215 - LGE Internal Use Only .Exploded View S4 chassis 135312 152302 152313 131410 159830 733010 342800 359011 135311 354210 147581 346810 35211B 268711A 135516 263230B 352150 266090 146811 263230A 267110 249951 268711B Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes . Only for training and service purposes .216 - LGE Internal Use Only .Exploded View S5 chassis 135312 152302 152313 152302 131410 733010 342800 159830 135311 354210 147581 359011 346810 35211B 268711A 135516 263230B 352150 266090 146811 263230A 267110 249951 268711B Copyright ©2007 LG Electronics. All right reserved. Inc. All right reserved. Only for training and service purposes 35211B 152302 146811B 147581 135500C 352380 131410 263230B 263230A 135311B 135500B 147581 135311A 346810 159830 349600 146811B 268711A 135311C 359012 135500A 147581 146811B 135316 .135515 249951 354210 130400 266090 268711C 267110 330870 352116 268711B 352115 SP1 chassis(Art cool type) 268711D 146811A 352150 Copyright ©2007 LG Electronics. Inc.217 - 135313 LGE Internal Use Only Exploded View . SZ chassis .A/C Motor) 146811 135316 152302 668713A 146811 668713B 135313 135080A 263020 135080B 263230B 263230A 733010 267110 159830 359011 342800 354210 131410 346810 352150 352114 352118 W0CZZ 35211B 266090 249951 146811A 147581 135311 268714 249941 Copyright ©2007 LG Electronics. Only for training and service purposes .218 - LGE Internal Use Only . All right reserved. Inc.Exploded View Art Cool Deluxe Type(SU. 219 - LGE Internal Use Only .Exploded View Art Cool Deluxe Type(SU. Only for training and service purposes . Inc. All right reserved.BLDC) 146811B 135316 152302 268711B 146811B 145200A 145200B 268711C 135313 135080A 263020 135080B 263230B 263230A 159830 733010 267110 359011 342800 354210 131410 346810 352150 352114 352118 266090 35211B 249951 146811A 147581 135311 268711A 249941 Copyright ©2007 LG Electronics. SZ chassis . All right reserved.Exploded View Art Cool Deluxe Type(S3 chassis . Inc. Only for training and service purposes .220 - LGE Internal Use Only .A/C Motor) 146811B 135316 152302 268711B 146811B 145200A 145200B 268711C 135313 263040 263230B 263230A 733010 267110 359011 159830 342800 354210 131410 346810 352150 352115 352116 266090 35211B 249951 146811A 147581 135311 268711A 249941 Copyright ©2007 LG Electronics. Only for training and service purposes .Exploded View Art Cool Deluxe Type(S3 chassis .221 - LGE Internal Use Only . Inc.BLDC) 146811B 135316 152302 268711B 146811B 145200A 145200B 268711C 135313 263040 263230B 263230A 733010 267110 359011 159830 354210 342800 131410 346810 352150 352115 352116 266090 35211B 249951 146811A 147581 135311 268711A 249941 Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes .Exploded View Art Cool Mirror Type(SE chassis . All right reserved. Inc.222 - LGE Internal Use Only .BLDC) 135316 152302 263230C 268711C 268711A 268711D 146811B 733010 159830 342800 267110 359011 354210 131410 352150 346810 135516 266090 35211B 147581 146811A 249951 268711B 135311 135500 263230A 263230B Copyright ©2007 LG Electronics. All right reserved.223 - LGE Internal Use Only .Exploded View DUCT LOW(B1) 263230A 263230C 159830 336600B 346810B 249951 268711A 346810A 359012A 263230B 268711B 336600A 354210 352118A 359012B 330870 352118B 267110 158591 352150 Copyright ©2007 LG Electronics. Only for training and service purposes . Inc. Inc. Only for training and service purposes .224 - LGE Internal Use Only . All right reserved.Exploded View DUCT LOW(B2) 263230A 159830 263230C 336600B 346810 359012A 249951 268711A 263230B 336600A 359012B 268711B 354210 267110 352118A 330870 352118B 158591 352150 Copyright ©2007 LG Electronics. High Static 359012B 137214 346810 359012A 336600A 336600B W0CZZ 249951 354210 152302 268711 352111 263230A 263230B 552111 352118 330870 263230C 267110 Copyright ©2007 LG Electronics.Exploded View Duct Type . Inc.225 - LGE Internal Use Only . All right reserved. Only for training and service purposes . Low Static (BT. Inc. Only for training and service purposes .Exploded View Duct Type . BT1 chassis) 152302 346810 336610 267111 359012B A/CL W0CZZ 359012A 354210 267110 249951 268714 552111 352118 330860 352111 263230A 263230B 263230C Copyright ©2007 LG Electronics. All right reserved.226 - LGE Internal Use Only . Only for training and service purposes . All right reserved.227 - LGE Internal Use Only . Inc.Exploded View Built in Duct type (BP chassis) 137214 249951 267110 263230A 263230B 336600A 359012B 263230C 268711 158591 W0CZZ 352118A 346810 359012A 336600B 352118B 354210 330870 237202 *Accessory: Front Panel Assembly. Copyright ©2007 LG Electronics. Inc. Only for training and service purposes 352115 354210 266090 268711 249951 159830 263230A 263230B 263230C .228 - LGE Internal Use Only Exploded View * Accessory: Front Panel Assembly. All right reserved.1 way (TC1 chassis) Copyright ©2007 LG Electronics.267110B 346810 130911 352390 267110A 352150 158591 135500 266010 359011 Option 330870 352116 Cassette Type . . 1 way (TC chassis) Copyright ©2007 LG Electronics.267110B 346810 130911 W1SZ Exploded View 267110A 354212 158591 266012 359011 137211 352116 Cassette Type .229 263230A 263230B 263230C 135802 738282 INS TA LL MA NU AL LGE Internal Use Only . Inc. All right reserved. Only for training and service purposes 330860 352115 354210 146811 152302 266090 W0CZZ 268714 249951 140570 152312 135312 159830 738290 OW NE RS MA NU AL 268712 . 4 way[TE chassis] 266090 249951 263230C 263230B 263230A 268711 159830 354211 352118 35211A 158591 266010 330870 352111 Applied for 18K Model Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes .Exploded View Cassette Type .230 - LGE Internal Use Only . Exploded View 130412 W0CZZ 346811 359012 140570 130911A * Accessory : Front Panel Assembly 267110B 130911B 352150 267110A (Optional) Copyright ©2007 LG Electronics. Only for training and service purposes .231 - LGE Internal Use Only . Inc. All right reserved. 4 way[TE(1) chassis] 266090 249951 263230C 263230B 263230A 268711 159830 354211 352118 35211A 158591 266010 330870 352111 Applied for 18K Model Copyright ©2007 LG Electronics. Only for training and service purposes . All right reserved.232 - LGE Internal Use Only .Exploded View Cassette Type . Inc. Exploded View 130412 359012 140570 130911A * Accessory : Front Panel Assembly 130911B 352150 267110A Copyright ©2007 LG Electronics.233 - LGE Internal Use Only . All right reserved. Inc. Only for training and service purposes . Only for training and service purposes . All right reserved.234 - LGE Internal Use Only . Inc.4 way(TF chassis) 266090 249951 268711 354211B 354211A 159830 263230C 352118B 263230A 263230B 552111 352118A 158591 266010 352111 330870 Copyright ©2007 LG Electronics.Exploded View Cassette Type . All right reserved.Exploded View 130412 W0CZZ 346810 359012 W4056 130911B * Accessory: Front Panel Assembly 267110B 267110A 352150 130911A Copyright ©2007 LG Electronics. Inc.235 - LGE Internal Use Only . Only for training and service purposes . 236 - LGE Internal Use Only .4 way(TH chassis) 266090 159830 268711 263230C 249951 130412 158591 354211 266010 552111 330870 263230A 263230B 352118 Copyright ©2007 LG Electronics. Only for training and service purposes . All right reserved. Inc.Exploded View Cassette Type . Inc.Exploded View 130412 346810 359012 130911B 140570 130912A * Accessory : Front Panel Assembly 130912B 352150 130911A 267110 Copyright ©2007 LG Electronics.237 - LGE Internal Use Only . Only for training and service purposes . All right reserved. 238 - LGE Internal Use Only . Inc.4 way(TD chassis) 249951 266090 159830 268714 263230A 263230B 130411 263230C 354211 352118A 552111 330870 352118B 158591 266012 Copyright ©2007 LG Electronics. Only for training and service purposes . All right reserved.Exploded View Cassette Type . Only for training and service purposes . Inc.239 - LGE Internal Use Only .Exploded View 130411 W0CZZ 146811 268712 346810 152312 359012 140570 130911B 130912A 135313 135802 267110A 137211 130912B 130911A 267110B 352150B Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes .240 - LGE Internal Use Only . All right reserved.Exploded View Convertible Type (VE chassis) 137211 268711C 147581 135310 152302 135313 146811 733010 267110 W0CZZ 266000 330870 352115 352116 135500 346810 263230A 354210 35211B 352150 268711B W4810 359011 342800 Applied for Plasma Model 159830 330780 266090 266000 Applied for Plasma Model 249951 263230B 268711A 131410 Copyright ©2007 LG Electronics. Inc. 135310 Exploded View 146811 147590A 346810 266000 Convertible Type (VB chassis) 147590B 130911 Copyright ©2007 LG Electronics. All right reserved.241 - 267110 137211 135314 LGE Internal Use Only 135303 . Only for training and service purposes 235450 237900 268711A 249951 352115 354210 35211A 263230A 263230B 268711C W0CZZ 330870 359011 152302 342800 352150 . Inc. 242 - LGE Internal Use Only Exploded View 435301 .437212 554031 558511 552113 435511 Outdoor Unit 552112 A2UW146FA2. Only for training and service purposes 559010 W0CZZ 261704 268711 649950 552116 661400A 554160 447910 661400B 552200 263230A 263230B 561410 W49810 437211 430411 552203A 552203B 552203A 552203B . A2UW166FA1 546810 Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes 559010 W0CZZ 261704 268711 649950 552116 661400A 554160 447910 661400B 552200 263230A 263230B 561410 W49810 437211 430411 552203A 552203B 552203A 552203B . All right reserved.243 - LGE Internal Use Only 435301 . Inc.437212 554031 Exploded View A2UW166FA0 552113 435511 552112 546810 Copyright ©2007 LG Electronics. A2UW146FA0 554031 437212 435512 552112 552113 Copyright ©2007 LG Electronics.244 - 435301 LGE Internal Use Only Exploded View . Inc. Only for training and service purposes 559010 W0CZZ 566000 268711 447910 261704 649950 263230A 552116 661400A 661400B 554160 552200 263230B 561410 435511 546810 W49810 552203A 552203B 552203A 552203B 437211 430411 . All right reserved. Only for training and service purposes 435511 . All right reserved. Inc.245 437211 430411 649950 552116 548490 661400A 661400B 661400C 554160 552200 435301 263230A 263230B 561410 W49810 552203A LGE Internal Use Only 552203B .Exploded View A3UW186FA1 554031 437212 435512 552112 552113 559010 W0CZZ 566000 268711 447910 261704 546810 Copyright ©2007 LG Electronics. A2UW186FA0 558511 Copyright ©2007 LG Electronics.246 - 435301 LGE Internal Use Only Exploded View . Only for training and service purposes 559010 W0CZZ 566000 268711 447910 261704 649950 435511 546810 263230A 552116 661400A 661400B 554160 552200 561410 263230B W49810 552203A 552203B 437211 430411 552203A 552203B . All right reserved. Inc.554031 137213A 435300 137213B 435512 552112 552113 A2UW146FA1. All right reserved.554031 437212 Exploded View A3UW186FA0 435512 552112 552113 558511 559010 W0CZZ 566000 Copyright ©2007 LG Electronics.247 - 435301 LGE Internal Use Only . Inc. Only for training and service purposes 546810 268711 447910 261704 435511 649950 263230A 263230B 561410 554160 552200 552116 661400A 661400B 661400C W49810 552203A 437211 430411 552203B . All right reserved.554031 137213A 435300 137213B 552111 552204 552115 552113 558511 A3UW246FA0 552201 552116 435512 566000 559010 649950 546810 261704 548490 561410A Copyright ©2007 LG Electronics. Inc. Only for training and service purposes 268711 435511 661400A W0CZZB W0CZZA 661400B 661400C 447910 561410C 561410B 554160A 552200 554160B 552203A 437210 W49810 552203B 430411 263230A 263230B 263230C .248 - 435301 LGE Internal Use Only Exploded View . 249 - 435301 LGE Internal Use Only . Only for training and service purposes 554160A 552200 554160B 552203A 552203B 437210 W49810 430411 263230A 263230B 263230C . Inc. All right reserved.554031 137213A 435300 137213B 552111 552204 552115 552113 558511 349600 559010 649950 548490 561410A 268711 561410B 447910 561410C 661400A W0CZZB W0CZZA 661400B 661400C 661400D 435511 546810 261704 Exploded View A4UW246FA0 552201 552116 435512 566000 Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes 649950 546810 561411A 561411 561411B 561411C 561411D 561410 554160 559010 552113A 552113B 437210 430410 552113 263230A . Inc. A4UW30GFA0 Copyright ©2007 LG Electronics.250 - 263230B 435301 LGE Internal Use Only Exploded View .137213A 554031 435300 548490 137213B 552115 552116 552111 435511 435512 668711 A4UW24GFA0. Inc.554031 137213A 435300 137213B 552201 552204 552115 352113 552111 Exploded View 566000 A4UW306FA0 561410A 552116 561410B 561410C 558511 548490 552113 546810A 559010 649950 435512 263230A Copyright ©2007 LG Electronics. All right reserved. Only for training and service purposes 546810B 268711 661400A 661400B W0CZZA W0CZZB W49810 552203A 447910 552200 554160B 554160A 552203B 661400C 661400D 435511 437210 261704 430411 263230B 263230C .251 - 435301 LGE Internal Use Only . 554031 137213A 435300 137213B 552201 552204 552115 352113 552111 566000 A4UW306FA1 561410A 552116 561410B 561410C 548490 552113 546810A 559010 649950 435512 558511 263230A Copyright ©2007 LG Electronics. Only for training and service purposes 546810B 268711 W0CZZA W0CZZB W49810 552203A 447910 554160B 554160A 552203B 435511 437210 261704 430411 263230B 263230C . All right reserved.252 - 435301 LGE Internal Use Only Exploded View . Inc. 435512 261704 649950 349600 237200 Exploded View A6UW406FA0 558511 546810A W0CZZA W0CZZB 669200 437212 268711 263230A 263230B 559010 447910 546810A 546810B 548490 552116 554031A 552111 263230C Copyright ©2007 LG Electronics. Inc. All right reserved. Only for training and service purposes 55211GB 554160A 554160B 55211GA 566000 552203A 554031B 552203B 430411 552115B 552113 552115A 661400 352112 437210 .253 - 435301 435511 137213 LGE Internal Use Only . P/NO : 3828A20097W NOVEMBER. 2007 .
Copyright © 2024 DOKUMEN.SITE Inc.