Level Indicators Visual-5!16!2011

March 21, 2018 | Author: afic219473 | Category: Switch, Electrical Resistance And Conductance, Nature


Comments



Description

SURESITE® LEVEL INDICATORSSureSite® Visual Liquid Level Indicators ...the safe alternative to cloudy, breakable sight glasses. High Visibility—Brilliantly colored flags are easy to read, even at great distances. The indicator is isolated from the measured media; therefore, SureSite Indicators can be used where sight glasses are not even a consideration. Durability—Stainless steel, PVC, CPVC, PVDF, Hastelloy or other exotic housings, whatever the media requirements, provide years of maintenance-free service. Environmentally Safe—Monitored liquid is contained inside a pressuretight housing. Efficient—Continuous level indication without external power. Electronic Control—Attach optional point level switches and/or continuous level transmitters to extend capabilities beyond those of a simple sight glass.      Engineered Plastic Low Maintenance—No glass to break, durable housings OSHA Friendly—Accident incidence reduction Reduced Workload—Quick and easy viewing shortens monitoring chores EPA Friendly—Fewer seals and no glass protect against spillage Multi-Purpose—Not single purpose as with sightglasses; can replace simple tank gauging systems as a complete level gauge package When Gems Sensors & Controls introduced SureSite® Liquid Level Indicators almost 30 years ago, no one had seen anything like them... sightglasses were the standard in liquid level indication. Well, we are happy to say that since that time SureSite Indicators have retired more sightglasses than we can count! Our success has spawned many imitators, but there is still only one SureSite Indicator with its many exclusive features, and more importantly there is no manufacturer so uniquely capable as Gems to be your sensor supplier. Fifty years of experience has taught us which technologies and product characteristics will provide the most effective solutions to your requirements. And our engineering resources have long been helping customers solve their most challenging application problems. So, there is a good chance we’ve already dealt with the design criteria you are working on. If you don’t see materials or configurations in the following pages to suit your needs, please give Gems a call for custom application assistance. Standard Size Alloy Miniature Size Alloy Contents Page Start Specifying and Ordering ..................................... D-3 Alloy Versions Miniature Size .................................................... D-4 Standard Size ........................................... D-7 High Performance SureSite ............................. D-10 Engineered Plastic Version ............................. D-13 Optional Transmitters ....................................... D-16 Optional Switch Modules ................................. D-18 Optional Indicating Scale ................................. D-18 Gems Serves the OEM and End User Gems welcomes any size order...whether a single unit or 100 units or more. Gems commitment is to meet your most stringent requirements of price, delivery and quality. Visit www.GemsSensors.com for most current information. D-1 LEVEL INDICATORS – VISUAL SureSite® Visual Liquid Level Indicators Simply the Most Versatile Liquid Level Monitoring System Available … and Tough Enough For All Kinds of Applications! Visual Indication 10 9 8 7 6 5 4 3 2 1 Comprehensive Indication • Pressures to 4200 PSI • Externally mounted electronics • Hi/Low alarms, Switch Points • ANSI Flange/ASME Type • Cenelec, FM, UL, CSA Approved EXPLOSION PROOF LEVEL SWITCHES • Handles full vacuum to high pressure • Highly visible from over 100 ft. (30m) • Eliminates downtime • Virtually maintenance free • Custom configured units INDICATING SCALE HIGH VISIBILITY INDICATOR FLAGS EXPLOSION PROOF CONTINUOUS OUTPUT TRANSMITTER Cold Service Applications • -200°F (-129°C) • Frost proof lens • Insulation (Cold Service) • Magnified visibility Hot Service Applications • Process temps to 750°F (399°C) • External electronics to 750°F (399°C) • High temp insulation available INSULATION BLANKET (Cut Away) LEVEL INDICATORS – VISUAL D-2 FROST PROOF LENS INSULATION BLANKET (Cut Away) HEAT TRACE Oil/Water Applications Oil Water Acid Applications • Fluid compatible materials Hastelloy C 276, PVDF, Alloy 20, Titanium • Eliminate dangerous/costly leaks HIGH LEVEL SWITCH FOR ALARM • Interface application • Materials: Stainless Steel, engineered plastics • Multiple process ports required • Electronics for pump control • Valves available • Consult factory for details HI AND LO LEVEL SWITCHES FOR VALVE CONTROL CONTINUOUS OUTPUT TRANSMITTER PVDF HOUSING AND FITTINGS Top mount units available. Contact factory for details. Versatile Design The SureSite Indicators described on the following pages represent only “basic designs.” An infinite variety of configurations can be derived, custom built to your exact dimensions and application specifications on existing or new tank designs. Visit www.GemsSensors.com for most current information. Accurately complete all of the purchasing information that we’ll need to process your order and fax it. These forms will provide us with the shipping and billing information we need. along with their fax numbers. check off the boxes and fill in the blanks of the OrderIt! Check List to specify your desired product configuration. or strict adherence to industry standards such as • ASME • CENELEC • CSA • FM • UL Gems High Performance SureSite Indicators are manufactured to fill these requirements. permanent bar magnet lies in a horizontal position within the float.GemsSensors.SURESITE® LEVEL INDICATORS SureSite Indicators Are Superior To Other Magnetic Type Indicators. The guide is FLAG FLAG FLAG integrated into the flag channel. See pages D-10 and D-11.gemssensors.com.457.171 Ordering SureSite® Indicators Order online or use our quick and easy OrderIt! Forms. but look closer and you’ll see they are not made the same. 2. . start by photocopying the appropriate OrderIt! PRODUCT CHECK LIST located on pages D-6. • A powerful. To order your CUSTOM product. Next. and D-15.gemssensors. Liquid level is indicated by the junction of the “color” and “contrasting” portions of the column. using the product information supplied in this section. CHANNEL FLAG so regardless of positioning. along with any prices or delivery dates quoted. Accurate answers to each question will assure correct fit and function of your custom built product. 4. Visit www. MAGNETIC INTERLOCK INTERLOCK vibration. surges or rapid level FLAG CHANNEL changes. either place your order over the phone with one of our representatives. a magnet-equipped floatMAGNETIC the unit within FLAGS PLAINinverts the magnetic SIDE-OUT flags in the external indicator to “colorMAGNETIC side-out. Here’s Why: It begins with a patented Flag Assembly and integrated Magnetic Guide Many magnetic flag type indicators look the same.” The flags FLOAT remain magnetically MAGNETIC FLAGS interlocked in COLORSIDE-OUT a column until again inverted FLAG to “contrastingCHANNEL side-out” by the floatSURESITE as liquid level HOUSING falls. CHANNEL PERMANENT MAGNET • Float capability to handle liquid PERMANENT FLAG PERMANENT MAGNET specific gravity range as low as MAGNET MAGNETIC GUIDE FLAG FLAG 0. FLAG CHANNEL CHANNEL the bar magnet within the float is always aligned for optimum performance and exactness.com for most current information. INTERLOCK MAGNETIC and is unaffected by shock. To obtain a priced quotation. 4. fax your completed OrderIt! Check List to Gems at 860-747-4244 or fax it to the Sales Partner nearest you. Flag FLOAT FLOAT CHANNEL rotation is positive and reliable. or use the OrderIt! method. are conveniently located on the Web at www.com. This LIQUID preferred attitude directs the flux density of the magnetic FLOAT CHANNEL field toward the flags. To specify this product. FLAG FLAG CHANNEL • A Magnetic Guide (a SureSite CHANNEL exclusive) enables the use of a more powerful bar magnet in FLAG the float assembly. Profile View Top View • A permanent magnet. 1. You can now configure and request quotes directly online at www. Flag Assembly (partial close-up) MAGNETIC GUIDE MAGNETIC Channel MAGNETIC GUIDE GUIDE SureSite® Indicators in the Process… Many applications require high temperature/pressure capabilities. They incorporate a patented design and special features that provide the ultimate in performance and reliable operation. All of our Sales Partner locations. D-12. MAGNETIC Proper alignment is assured. D-9. SureSite® Indicators are unique. forms a secure magnetic interlock with adjacent flags. D-12. D-9. Just photocopy the appropriate OrderIt! PRODUCT CHECK LIST (D-6. encapsulated into each flag.40. MAGNETIC GUIDE ENCAPSULATED PERMANENT MAGNETS ENCAPSULATED ENCAPSULATED PERMANENT PERMANENT MAGNETS MAGNETS MAGNETIC GUIDE Operating Principle As liquid level rises. Note: Use a separate Check List for each unique configuration. 3. MAGNETIC FLAGS PLAINSIDE-OUT MAGNETIC FLOAT MAGNETIC FLAGS COLORSIDE-OUT FLAG CHANNEL SURESITE HOUSING LIQUID TANK TANK LEVEL INDICATORS – VISUAL D-3 Pa Patent No. and/ or D-15). Mounting Configuration Types Type AM Top and Bottom Process Connections T Sa T Type BM Side and Side Process Connections Type CM Top and Side Process Connections Type DM Side and Bottom Process Connections Sa PRESSURE PSI LEVEL INDICATORS – VISUAL D-4 L = Length of Visual Indication L C to C L C to C L C to C L C to C B Sb Sb B Typical Lengths* Flag Material Length of Indication (Uninterrupted) C to C = L + 7.Alloy Versions–Miniature Size  Lengths to over 20 feet (6.72˝ (196 mm) C to C = L C to C = L + 3˝ (76 mm) C to C = L + 5˝ (127 mm) Plastic (300°F/148. . Mini SureSite Indicators are ideal for use with clean. floats.9°C) or Aluminum (400°F/204°C) 240˝ (610 cm) *Dimensions vary due to connections. to perform within the Pressure/Temperature parameters specified in the chart at right.GemsSensors.1 meters)  316 Stainless Steel construction  Pressures to 400 PSI (27 bar) – Temperature to 400°F (204°C) Use these Mini SureSite Indicators where space is tight—they feature a diameter of only 1-1/4˝! They can replace existing. Easy online ordering too! 1. 400 373 300 200 150 100 0 0 100 200 300 400 TEMPERATURE — F° Note: SureSite Indicators are available for temperatures as low as -200°F (-129°C) Visit www. connections and manufacturing techniques are available to extend lengths and operational capabilities. Consult the factory with pressure/temperature requirements that fall outside the parameters shown here. Typical Applications • Pharmaceuticals • Medical Equipment • Food and Beverages • Semiconductor Manufacturing • Boilers Ordering is Easy! See Page D-6. antiquated sightglasses for excellent external. visual liquid level indication. low viscosity liquids. Please contact Gems if the parameters above do not meet your requirements.com for most current information. Miniature SureSite Performance Gems configures Miniature SureSite Indicators. Note: Additional materials. material and specific gravity. using various materials and fittings. com for further details. 11.Not Both. 3. No connection MNPT nipple FNPT coupling ANSI flange Sanitary flange Buttweld nipple Available for up to 10 units 3-Day Qwik Configured Built & Shipped in 3 Days! T/B 12.com for most current information. T/B 20. Others available upon request. gemssensors. Visit www. Connection Code Descriptions Please provide all connections when completing the OrderIt! Product Check List (located on the following page). S6. Minimum specific gravity is 0. Select these connections where possible to obtain the most economical SureSite Indicators with a prompt 3-day delivery. 4. D-5 Performance Notes: 1. S5. etc. T/B 13. Connection Codes (See complete descriptions below) Blind Fixed Removable T10 Fixed Male Female T2 NPT T3 Removable Male Female T11 T12 Flange Fixed T19 Removable T20 Weld Socket Removable Butt Butt T18 T13 Standard Connections T1 T Sa TOP Sanitary Connections T7 T8 SIDE Blind S1 Male NPT S2 Female S3 Flange S4 Sanitary Flange S5 Buttweld Nipple S6 — Connection Codes and Materials BOTTOM B Standard Connections Blind Fixed B1 Removable B10 Fixed Male Female B2 NPT Removable Male Female B11 B12 Flange Fixed B19 Removable B20 Weld Socket Removable Butt Butt B18 B13 B3 Sanitary Connections B7 B8 Note: Gems recommends a removable top and/or bottom connection for float access. LEVEL INDICATORS – VISUAL Sb SIDE background-shaded in this color are stocked by Gems. alarms. S3. • Continuous Output Transmitters Signal conditioned for compatibility with most electronic instruments to 300°F (149°C). Standard O-ring seal material is Viton®.SURESITE® LEVEL INDICATORS 2. Electropolished Outer Diameter (OD) and/or Inner Diameter (ID) housings available upon request.GemsSensors. . 8. T & B (Top and Bottom) T/B T/B T/B T/B T/B T/B T/B 1. S2. • Switch Modules Control pumps. T/B 18. 2. Note: Before selecting your connections. 10. Mount externally on housing for infinite positioning. Need it quick? Choose materials and components with the color shading for 3-Day manufacturing and shipping. T/B 19.7. S4. See the Product Configurator section at www. Accessories – Pages D-16 to D-18 Make more of your SureSite® Indicator with the productivity-enhancing accessories found at the end of this section. 3. 2. 7. consider incorporating your vent and drain requirements. As an option either the Switch Modules or Transmitter can be used on a Miniature SureSite Indicator . • Indicating Scales Add graduations to your flag indication. valves. Welded cap Welded cap with FNPT Welded cap with MNPT Sanitary flange Sanitary flange with mating blind flange Standard fixed flange/mating blind flange Standard fixed flange/mating FNPT reducing flange Standard fixed flange/mating flange with MNPT nipple Standard fixed flange/mating flange with butt weld nipple Welded cap with butt weld nipple Welded cap with ANSI flange Standard fixed flange/mating reducing flange spool with ANSI flange Sa & Sb (Sides) S1. Length of Visual Indication – L: _____ inches (240˝.O. CT 06062-1198 Sensors & Controls tel 860. 1.  Connection Code Number Goes Here. Max. Viscosity: _________________ SSU 6. Please complete fully and accurately.) Accessories (Pages D-16 to D-18) 1.  Plastic (Orange and White)  Aluminum (Black and Silver)  Non-Standard. etc. specify: _______________________ 3. Specific Gravity @ Operating Condition: ____________________ 5. Indicating Scales:  Feet and Inches  Inches  Metric  Blank  Custom Graduations. for any configuration or special requirements not covered on this form.SureSite® ViSual indicatorS – Miniature Size.747.  SPST  SPDT  DPDT 120 VAC  DPDT 24 VDC b. Application Location:  Indoors  Outdoors Physical Configuration 1. Mounting Configuration Types:  Type AM  Type BM  Type CM  Type DM 2. . Continuous Transmitter: Output:  0-5 VDC  0-12 VDC  4-20 mA J-Box:  Standard  Explosion Proof D-6 Please contact GEMS Sensors Inc.747.com Visit www. Connection Code Numbers and their descriptions are on Page D-5. consult factory.4244 www. Flag Type Plastic flags available to 300°F (149°C).# ______ Name __________________________________________ Company ________________________________________ Street __________________________________________ City_______________________ State ____ Zip__________ Phone ( _____ ) __________________________________ Fax ( _____ ) _____________________________________ Quantity Needed ____________ Photocopy This Form Use one form for each product type you are selecting. alloy   Product Check List This is a  Request for a Quote  Order P. Date Required ____/____/_____ Shipping Method:____________ Partials Accepted:  Yes  No SureSite Indicators.GemsSensors. This form may also be completed online at gemssensors. Alloy Versions – Miniature Size Process Conditions This information is essential to the accurate and proper operation of your SureSite® Visual Level Indicators. Aluminum flags only for temperatures to 750°F (399°C). Temperature: Operating ________ °F Maximum __________°F 3. Connections.gemssensors. Connection to Connection Dimension – C to C: ________ inches.).3000 fax 860.com for RFQ. O-Ring Material:  Viton® (Standard)  Ethylene Propylene  Other ________________________________________________ 4. Special Instructions (Materials. Check off NPT or Flange size where appropriate. 800-378-1600 Quote $ _____________________ Date Quoted ____/____/____ Gems Sensors & Controls One Cowles Road Plainville.  Standard – 300°F  High Temperature  Explosion Proof 2. Connection Codes – Complete all 4 connection code lines. Liquid Media: _________________________________________ 4. Top T NPT or Weld  1/2˝  3/4˝  Other _____________ Flange  1/2˝  3/4˝  1˝  150# RF  300# RF  Other _____________  Other _____________ Flange  1/2˝  3/4˝  1˝  150# RF  300# RF  Other _____________  Other _____________ Flange  1/2˝  3/4˝  1˝  150# RF  300# RF  Other _____________  Other _____________ Flange  1/2˝  3/4˝  1˝  150# RF  300# RF  Other _____________  Other _____________ Side Sa NPT or Weld  1/2˝  3/4˝  Other _____________ Side Sb NPT or Weld  1/2˝  3/4˝  Other _____________ Bottom B NPT or Weld  1/2˝  3/4˝  Other _____________ 3. Specify:____________________ . Pressure: Operating __________ psig Maximum ________ psig 2. 5. Switch Modules (Single Point): _________ Quantity a.com for most current information. material and specific gravity. focus on the process connections (connections where the liquid typically enters/leaves the SureSite). connections and manufacturing techniques are available to extend lengths and operational capabilities. Type AA Top and Bottom Process Connections T Sa L C to C L & C to C L C to C T Ordering is Easy! See Page D-9. D-7 LEVEL INDICATORS – VISUAL . 2. floats. = Stock Material (Best economy and delivery). Note: Additional materials.GemsSensors.SURESITE® LEVEL INDICATORS Standard Alloy Versions – Standard Size  Temperatures to 750°F (399°C)  Pressures to 700 PSI (48 bar) Rugged.1 mm) Plastic (300°F/148.8 +93.4 mm) C to C = L C to C = L + 3-3/4˝ (95.5 mm) diameter design.9°C) or Aluminum (750°F/399°C) 240˝ (610 cm) 0. Please contact GEMS Sensors if the parameters above do not meet your requirements. welded construction makes these 2-1/2˝ (63. Mounting Configuration Types To choose the best configuration for your application. 1. Visit www.9 +204 +260 TEMPERATURE 600 +316 700 +371 800 +427 °F °C * Consult factory for pressure/temperature capabilities. Please consult the factory with temperature/pressure requirements that fall outside the parameters shown here. Note: SureSite Indicators are available for temperatures as low as -200°F (-129°C). Material Housing and Float: 316 Stainless Steel Pressure/Temperature performance parameters for alloy SureSite versions are specified in the chart at right.3 +148.2 mm) C to C = L + 6-1/2˝ (165. Materials Housing 316L Stainless Steel Carpenter 20 Hastelloy C276 Float 316L Stainless Steel Hastelloy C276 Hastelloy C276 Code 2 3* 900 (62) PRESSURE PSI (BAR) 600 (41) Type BA Shown 300 (21) Standard Alloy 0 4* 400 500 0 100 200 300 -17. alloy SureSite Indicators dependable over a long service life indoors and out. Easy online ordering too! Type BA Side and Side Process Connections Type CA Top and Side Process Connections Type DA Side and Bottom Process Connections Sa L = Length of Visual Indication L C to C B Sb Sb B Typical Lengths* Flag Material Length of Indication (Uninterrupted) Minimum Specific Gravity C to C = L + 10-1/4˝ (260.com for most current information.39 * Dimensions vary due to connections.8 +37. 5. 2. • Continuous Output Transmitters Signal conditioned for compatibility with most electronic instruments to 300°F (149°C). Select these connections where possible to obtain the most economical SureSite Indicators with a prompt 3-day delivery. look to SureSite Top Mount Indicators for the solution. Accessories – Pages D-16 to D-18 Make more of your SureSite® Indicator with the productivity-enhancing accessories found at the end of this section. 8. Visit www. Mount externally on housing for infinite positioning. See the Product Configurator section at www. • Switch Modules Control pumps. 6. No connection MNPT nipple FNPT coupling ANSI flange Available for up to 10 units 3-Day Qwik Configured Built & Shipped in 3 Days! Top Mount Units When it’s not practical to access the side of a tank for liquid monitoring. 3.GemsSensors. valves. S3. Connection Codes (See complete descriptions below) Blind Fixed Removable Female T1 T2 Fixed Male NPT Removable Male Female T6 T8 Flange Fixed T9 Removable T10 T Sa Blind SIDE TOP T3 T5 S1 S2 BOTTOM Male NPT Female S3 Flange S4 Sb Blind SIDE Connection Codes and Materials background-shaded in this color are stocked by Gems.3. Welded pipe cap Standard fixed flange/blind mating flange Welded pipe cap w/FNPT Welded pipe cap w/MNPT nipple Standard fixed flange/mating FNPT reducing flange Standard fixed flange/mating flange with MNPT nipple Welded pipe cap with ANSI flange Standard fixed flange/mating reducing flange spool Sa & Sb Sides S1.com for most current information. S2. 10. Note: Before selecting your connections. • Indicating Scales Add graduations to your flag indication. Need it quick? Choose materials and components with the color shading for 3-Day manufacturing and shipping. T & B (Top and Bottom) T/B T/B T/B T/B T/B T/B T/B T/B 1. Please consult with the factory for these specially configured indicators 1-800-378-1600. alarms. S4. . Flange Fixed B8 B9 LEVEL INDICATORS – VISUAL D-8 BOTTOM B Fixed B1 Removable B2 Fixed Female Male B3 NPT Removable Female Male B6 Removable B10 B5 Connection Code Descriptions Please provide all connections when completing the OrderIt! Product Check List (located on the following page).com for further details. consider incorporating your vent and drain requirements. 9. etc. gemssensors. Top T NPT  1/2˝  1˝  2˝  Other ____________  1/2˝  1˝  Other ____________  2˝ Flange  150# (RF)  600# (RF)  Other _______________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (RF)  600# (RF)  Other _______________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (RF)  600# (RF)  Other _______________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (RF)  600# (RF)  Other _______________________________ Side Sa NPT  1/2˝  1˝  2˝  Other ____________ Side Sb NPT  1/2˝  1˝  2˝  Other ____________ Bottom B NPT  1/2˝  1˝  2˝  Other ____________ 4. Housing and Float Material  Code 2  Code 3  Code 4 3. Indicating Scales:  Feet and Inches  Inches  Metric  Blank  Custom Graduations. Special Instructions (Materials. Length of Visual Indication – L: _____ inches (240˝. Date Required ____/____/_____ Shipping Method:____________ Partials Accepted:  Yes  No SureSite Indicators. CT 06062-1198 Sensors & Controls Visit www.GemsSensors.4244 www.O. Mounting Configuration Types:  Type AA  Type BA  Type CA  Type DA 2. Please complete fully and accurately. Accessories (Pages D-16 to D-18) 1.com SureSite® ViSual indicatorS – Standard Size. Check off NPT or Flange size where appropriate. Specify:_____________________ consult factory. Connections.747. 1. Specific Gravity @ Operating Condition: ____________________ 5. Connection Codes – Complete all 4 connection code lines. Max.com for most current information.  Connection Code Number Goes Here.  Plastic (Orange and White)  Aluminum (Black and Silver)  Non-Standard.This is a  Request for a Quote  Order P. Flag Type Plastic flags available to 300°F (149°C). J-Box/Signal Conditioners Accessories:  Terminal Strip  4-20 mA Output  0-12 VDC Output  0-5 VDC Output 3.) 5. Power Supply:  115 VAC (Input) /24 VDC (Output) (Optional)  230 VAC (Input) /24 VDC (Output) Please contact GEMS Sensors Inc. Pressure: Operating __________ psig Maximum ________ psig 2. Application Location:  Indoors  Outdoors Physical Configuration 1. Transmitters (Continuous Electrical Indication):  Low Temperature – 300°F (149°C)  Explosion-Proof  High Temperature – 750°F (399°C) 2. Switch Modules (Single Point): _______ Quantity (only if required) a. specify: _______________________ Gems Sensors & Controls One Cowles Road Plainville. for any configuration or special requirements not covered on this form.747. 800-378-1600 Quote: $ _______________ Date Quoted:____/____/____ 4. etc.# ______ Name __________________________________________ Company ________________________________________ Street __________________________________________ City_______________________ State ____ Zip__________ Phone ( _____ ) __________________________________ Fax ( _____ ) _____________________________________ Quantity Needed ____________ Photocopy This Form Use one form for each product type you are selecting.  SPST  SPDT  DPDT 120 VAC  DPDT 24 VDC b. Connection to Connection Dimension – C to C: ________ inches. Temperature: Operating ________ °F Maximum __________°F 3.). Connection Code Numbers and their descriptions are on Page D-8. Liquid Media: _________________________________________ 4.  Standard – 300°F (149°C)  Explosion Proof  High Temperature – 750°F (399°C) 5. Viscosity: _________________ SSU 6. This form may also be completed online at gemssensors.3000 fax 860. tel 860.gemssensors. Alloy Versions – Standard Size Process Conditions This information is essential to the accurate and proper operation of your SureSite® Visual Level Indicators. alloy D-9   Product Check List . Aluminum flags only for temperatures to 750°F (399°C).com for RFQ. GemsSensors.1/B31. focus on the process connections (connections where the liquid typically enters/leaves the SureSite). Type AA Top and Bottom Process Connections T Sa T Ordering is Easy! See Page D-12. *Units requiring ASME certification must be specified at time of request.com for most current information. Consult the factory with pressure/temperature requirements that fall outside the parameters shown here. You can’t specify a better visual level indicator.39 † Dimensions vary due to connections. Please contact Gems if the parameters above do not meet your requirements. 80 or 160 pipe accordingly. The pressure/temperature performance parameters are specified in the chart at right. connections and manufacturing techniques are available to extend lengths and operational capabilities. . floats. Visit www. these SureSite® Indicators feature ANSI flanges and fittings and construction to rigorous ASME standards.9°C) or Aluminum (750°F/399°C) 240˝ (610 cm) 0. These units are manufactured in Schedule 40. 2. Materials Housing 316L Stainless Steel Float 316L Stainless Steel 600 psi – Code 2 9 4200 (290) 4000 (276) 3800 (262) 3600 (248) 3400 (234) 3200 (221) 3000 (207) 2800 (193) 0 0 -18 100 +38 200 +93 400 500 300 +149 +204 +260 TEMPERATURE Consult Factory High Performance Titanium (Ti-6AI-4V) 316L Stainless Steel 600 psi+ 600 +316 700 +371 800 +427 °F °C Note: Additional materials. = Stock Material (Best economy and delivery).4 mm) C to C = L C to C = L + 3-3/4˝ (95. material and specific gravity. Mounting Configuration Types To choose the best configuration for your application. Easy online ordering too! Type BA Side and Side Process Connections Type CA Top and Side Process Connections Type DA Side and Bottom Process Connections Sa PRESSURE PSI (BAR) LEVEL INDICATORS – VISUAL D-10 L = Length of Visual Indication L C to C L & C to C L C to C L C to C B Sb Sb B Typical Lengths† Flag Material Length of Indication (Uninterrupted) Minimum Specific Gravity C to C = L + 10-1/4˝ (260. Mark the Code Number on your OrderIt! Check List. Material Select desired material from those tabulated below.1 mm) Plastic (300°F/148.High Performance Versions – Standard Size  Designed to meet the requirements of ASME B31. 1.2 mm) C to C = L + 6-1/2˝ (165.3*  Temperatures to 750°F (399°C)  Pressures to 4200 PSI (290 bar) For your most demanding applications. 17. Select these connections where possible to obtain the most economical SureSite Indicators. FNPT coupling S4. 22. Buttweld nipple Accessories – Pages D-16 to D-18 Make more of your SureSite® Indicator with the productivity-enhancing accessories found at the end of this section. • Continuous Output Transmitters Signal conditioned for compatibility with most electronic instruments to 300°F (149°C). D-11 Visit www. 30. 26. • Switch Modules Control pumps. 20. Weldneck flange S6. alarms.GemsSensors. MNPT nipple S3. 25. Connection Codes All connections comprised of ANSI fittings (See complete descriptions below) Blind Fixed T15 Removable T16 Fixed Male Female T17 NPT Removable Female Male T20 T22 Flange Fixed T23 Removable T24 Fixed Butt Socket T25 Weld T26 Removable Butt Socket T27 T28 T19 T Sa SIDE TOP T29 T30 T32 T33 T34 T35 Blind S1 NPT Male Female S2 Flange S4 S5 S3 Weld Socket Butt S6 S7 Sb B Blind Fixed B15 BOTTOM Removable B16 Fixed Female Male B17 NPT Removable Female Male B20 B22 Flange Fixed B23 Removable B24 Fixed Butt Socket B25 Weld B26 Removable Butt Socket B27 B28 B19 B29 B30 B32 B33 B34 B35 Note: Gems recommends a removable top and/or bottom connection for float access. valves. . 32. Connection Code Descriptions Please provide all connections when completing the OrderIt! Product Check List. ANSI flange S5. LEVEL INDICATORS – VISUAL SIDE Connection Codes and Materials backgroundshaded in this color are readily available from Gems. 28. Note: Before selecting your connections. 34. Socketweld coupling S7. consider incorporating your vent and drain requirements. 23. No connection S2. 24.com for most current information. T & B (Top and Bottom) T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B 15. 33. 27. 16. Mount externally on housing for infinite positioning. 29. 19. 35. • Indicating Scales Add graduations to your flag indication. etc. ANSI welded pipe cap ANSI fixed slip-on flange/blind mating flange ANSI welded pipe cap with FNPT ANSI welded pipe cap with MNPT nipple ANSI fixed slip-on flange/mating FNPT reducing flange ANSI fixed slip-on flange/mating flange w/MNPT nipple ANSI welded pipe cap with ANSI flange ANSI fixed slip-on flange/mating reducing ANSI flange spool ANSI welded pipe cap with socketweld coupling ANSI welded pipe cap with buttweld nipple ANSI fixed slip-on flange/mating flange with socketweld coupling ANSI fixed slip-on flange/mating flange with buttweld nipple ANSI fixed weldneck flange/blind mating flange ANSI fixed weldneck flange/mating FNPT reducing flange ANSI fixed weldneck flange/mating flange w/MNPT nipple ANSI fixed weldneck flange/mating reducing flange spool ANSI fixed weldneck flange/mating flange with socketweld coupling ANSI fixed weldneck flange/mating flange with buttweld nipple Sa & Sb (Sides) S1.SURESITE® LEVEL INDICATORS 3. gemssensors.3000 fax 860. Check off NPT or Flange size where appropriate.  SPST  SPDT  DPDT 120 VAC  DPDT 24 VDC b.O. Power Supply:  115 VAC (Input) /24 VDC (Output) (Optional)  230 VAC (Input) /24 VDC (Output) Please contact Gems for any configuration or special requirements not covered on this form.5˝  Other ____________ 4. Accessories (Pages D-16 to D-18) 1. Temperature: Operating ________ °F Maximum __________°F 3. Length of Visual Indication – L: _____ inches (240˝. Connection to Connection Dimension – C to C: ________ inches.  ASME Stamp Required Special Instructions (Materials. Switch Modules (Single Point): _______ Quantity (only if required) a. Liquid Media: _________________________________________ Use this page for high performance units only.GemsSensors. Top T NPT or Weld  1/2˝  1˝  1.5˝  Other ____________  1/2˝  1˝  Other ____________  2˝ Flange  150# (RF)  600# (RF)  900# (RF)  Other ______________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (RF)  600# (RF)  900# (RF)  Other ______________________________ Flange  1/2˝  1˝  Other____________  2˝  150# (RF)  600# (RF)  900# (RF)  Other ______________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (RF)  600# (RF)  900# (RF)  Other ______________________________ Side Sa NPT or Weld  1/2˝  1˝  1. Max.# ______ Name __________________________________________ Company ________________________________________ Street __________________________________________ City_______________________ State ____ Zip__________ Phone ( _____ ) __________________________________ Fax ( _____ ) _____________________________________ Quantity Needed ____________ Photocopy This Form Use one form for each product type you are selecting.5˝  Other ____________ Bottom B NPT or Weld  1/2˝  1˝  1. Specific Gravity @ Operating Condition: ____________________ 5.747. Mounting Configuration Types:  Type AA  Type BA  Type CA  Type DA 2.747. High Performance Versions Process Conditions This information is essential to the accurate and proper operation of your SureSite® Visual Level Indicators. Connection Code Numbers and their descriptions are on Page D-11.). specify: _______________________ Gems Sensors & Controls One Cowles Road Plainville. tel 860. Pressure: Operating __________ psig Maximum ________ psig 2. 800-378-1600 D-12 Quote: $ _______________ Date Quoted:____/____/____ 4. J-Box/Signal Conditioners Accessories:  Terminal Strip  4-20 mA Output  0-12 VDC Output  0-5 VDC Output 3.  Standard – 300°F (149°C)  Explosion Proof  High Temperature – 750°F (399°C) 5. Specify aluminum flags for temperatures of 301°F to 750°F (149°C to 399°C). Application Location:  Indoors  Outdoors Physical Configuration 1.com . CT 06062-1198 Sensors & Controls Visit www. 1. 6.  Plastic (Orange and White)  Aluminum (Black and Silver)  Non-Standard. Transmitters (Continuous Electrical Indication):  Low Temperature – 300°F (149°C)  Explosion-Proof  High Temperature – 750°F (399°C) 2.5˝  Other ____________ Side Sb NPT or Weld  1/2˝  1˝  1. 4. Indicating Scales:  Feet and Inches  Inches  Metric  Blank  Custom Graduations.com for most current information. Viscosity: _________________ SSU 6. Connections. etc. Specify:_____________________ consult factory. Please complete fully and accurately. Connection Codes – Complete all 4 connection code lines. Date Required ____/____/_____ Shipping Method:____________ Partials Accepted:  Yes  No SureSite Indicators.SureSite® ViSual indicatorS – HigH Performance   Product Check List This is a  Request for a Quote  Order P. Housing and Float Material – Housing: 316L/SS  Code 2 – 316L SS Float  Code 9 – Titanium Float 3.4244 www.  Connection Code Number Goes Here. Flag Type Plastic flags available to 300°F (149°C).) 5. floats.6 +79. Mark the Code Number on your OrderIt! Check List. or with almost any liquid where temperature and pressure requirements are moderate.7 +65.9) 75 (5. Consult the factory with pressure/ temperature requirements that fall outside the parameters shown here.0) 150 (10.7) 0 0 -17. = Stock Material (Best economy and delivery). D-13 LEVEL INDICATORS – VISUAL Side and Bottom Process Connections .GemsSensors. 1.5˝ (241 mm) Overall Length = C to C + 5-1/2˝ (140 mm) Plastic C to C = L + 9.5 +93.3 Bar)  Up to 19 feet (5.2) 50 (3. Please contact GEMS Sensors if the parameters above do not meet your requirements.com for most current information. connections and manufacturing techniques are available to extend lengths and operational capabilities. Easy online ordering too! Type BP Side and Side Process Connections Type CP Top and Side Process Connections T Type DP Sa L = Length of Visual Indication L C to C L C to C L C to C L C to C B Sb Sb B Typical Lengths* Flag Indicator Material Length of Indication.8 +51. material and specific gravity. Note: Additional materials.9 +37.8) 175 (12.3) 125 (8.9 50 +10 PVC PVDF °F 100 125 150 175 200 75 +23. Materials Housing & Float PVC Clear PVC Housing/ PVC Float CPVC PVDF * 2" Schedule 40 pipe Pressure/Temperature Performance Code PRESSURE PSI (BAR) 200 (13. C to C = L + 11˝ (279 mm) Overall Length = C to C C to C = L + 8˝ (203 mm) Overall Length = C to C + 11˝ (279 mm) C to C = L + 9. All SureSite Indicators feature the same patented flag and guide assemblies used on our alloy versions. Type AP Top and Bottom Process Connections T Sa Ordering is Easy! See Page D-15.8 25 -3.8 meters) of continuous visual indication The 2˝ Schedule 80 pipe design is ideal for use on chemical storage tanks.6) 100 (6. so you can be assured of excellent visibility and long-life reliability.SURESITE® LEVEL INDICATORS Engineered Plastics Versions – Standard Size  Temperatures to 280°F (139°C)  Pressures to 150 PSI (10. Material Select desired material from those tabulated below. The pressure/ temperature performance parameters are specified in the charts at right. Max. focus on the process connections (connections where the liquid typically enters/leaves the SureSite).4) 25 (1.5˝ (241 mm) Overall Length = C to C + 5-1/2˝ (140 mm) 228˝ (579 cm) Type BP Shown *Dimensional data varies due to connections. Mounting Configuration Types To choose the best configuration for your application.3 °C TEMPERATURE CPVC 1 1A* 2 4 Consult Factory Visit www. 2. . Welded cap Threaded cap (PVC/CPVC only) Fixed flange/blind mating flange Welded coupling/FNPT Welded coupling/MNPT Threaded union/MNPT Fixed flange/mating flange MNPT Fixed flange/mating flange/FNPT Welded coupling flange Threaded union flange Sa & Sb (Sides) S1 S2 S3 S4 – – – – Blind–No Connection MNPT nipple FNPT coupling ANSI flange Accessories – Pages D-16 to D-18 Make more of your SureSite® Indicator with the productivity-enhancing accessories found at the end of this section. • Indicating Scales Add graduations to your flag indication.GemsSensors. T & B (Top and Bottom) T/B T/B T/B T/B T/B T/B T/B T/B T/B T/B 1. valves. • Switch Modules Control pumps. • Continuous Output Transmitters Signal conditioned for compatibility with most electronic instruments.3. 6. Visit www. 11. Note: Before selecting your connections. alarms. 5. Select these connections where possible to obtain the most economical SureSite Indicators. consider incorporating your vent and drain requirements. 3. 10. 2. 9. 7. etc. Mount externally on housing for infinite positioning. Connection Codes (See complete descriptions below) Blind Fixed TOP T1 Removable T2 Fixed Female Male T3 T4 NPT T5 T T6 Removable Male Female T7 Flange Fixed T10 Removable T11 T9 SIDE Sa Blind S1 Male S2 NPT Female Flange S4 S3 Connection Codes and Materials backgroundshaded in this color are stocked by Gems. SIDE Sb Blind NPT B5 LEVEL INDICATORS – VISUAL D-14 BOTTOM B Fixed B1 Removable B2 B3 Fixed Female Male B4 B6 Removable Male Female B7 B9 Flange Fixed B10 Removable B11 Connection Code Descriptions Please provide all connections when completing the OrderIt! Product Check List. 4.com for most current information. Application Location:  Indoors  Outdoors Physical Configuration 1.) 5. PlaStic D-15   Product Check List .GemsSensors.747. Indicating Scales:  Feet and Inches  Inches  Metric  Blank  Custom Graduations.  Standard – 300°F (149°C)  High Temperature  Explosion Proof 5.O. specify: _______________________ Gems Sensors & Controls One Cowles Road Plainville. Connections. Engineered Plastic Versions – Standard Size Process Conditions This information is essential to the accurate and proper operation of your SureSite® Visual Level Indicators.3000 fax 860. Power Supply:  115 VAC (Input) /24 VDC (Output) (Optional)  230 VAC (Input) /24 VDC (Output) 4.com SureSite® ViSual indicatorS – Standard Size.). Pressure: Operating __________ psig Maximum ________ psig 2. J-Box/Signal Conditioners Accessories:  Terminal Strip  4-20 mA Output  0-5 VDC Output  0-12 VDC Output 3.747. Connection Codes – Complete all 4 connection code lines. Specific Gravity @ Operating Condition: ____________________ 5. tel 860.This is a  Request for a Quote  Order P.# ______ Name __________________________________________ Company ________________________________________ Street __________________________________________ City_______________________ State ____ Zip__________ Phone ( _____ ) __________________________________ Fax ( _____ ) _____________________________________ Quantity Needed ____________ Photocopy This Form Use one form for each product type you are selecting. Mounting Configuration Types:  Type AP  Type BP  Type CP  Type DP 2.com for most current information. Switch Modules (Single Point): _______ Quantity (only if required) a.  SPST  SPDT  DPDT 120 VAC  DPDT 24 VDC b. Please complete fully and accurately. Temperature: Operating ________ °F Maximum __________°F 3. Flag Type: Plastic (Orange and White) Accessories (Pages D-16 to D-18) 1. Transmitters (Continuous Electrical Indication):  Standard – 300°F (149°C)  Explosion-Proof 2. Date Required ____/____/_____ Shipping Method:____________ Partials Accepted:  Yes  No SureSite Indicators. Check off NPT or Flange size where appropriate. Length of Visual Indication – L: _____ inches (228˝.gemssensors. etc.4244 www. Viscosity: _________________ SSU 6. 800-378-1600 Quote: $ _______________ Date Quoted:____/____/____ Visit www. CT 06062-1198 Sensors & Controls Please contact Gems for any configuration or special requirements not covered on this form. Special Instructions (Materials. Max. Connection to Connection Dimension – C to C: ________ inches. 1. Flange  150# (FF)  Other ____________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (FF)  Other ____________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (FF)  Other ____________________________ Flange  1/2˝  1˝  Other ____________  2˝  150# (FF)  Other ____________________________ Side Sa NPT  1/2˝  1˝  2˝  Other ____________ Side Sb Bottom B NPT  1/2˝  1˝  2˝  Other ____________ NPT  1/2˝  1˝  2˝  Other ____________ 4. Liquid Media: _________________________________________ 4. Connection Code Numbers and their descriptions are on Page D-14. Housing and Float Material:  Code 1  Code 1A  Code 2  Code 3  Code 4 3. Top T NPT  1/2˝  1˝  2˝  Other ____________  1/2˝  1˝  Other ____________  2˝  Connection Code Number Goes Here. Select your transmitter preference on the SureSite Product Check List (pages D-6. Voltage outputs available: • 0-5VDC • 0-10VDC • 0-12 VDC Current output available: • 4-20mA (loop powered) Electrical specifications and ordering information for these units are found on Page D-17.Continuous Electrical Output Transmitters for all SureSite Indicators Broaden the SureSite Indicator’s capabilities. Housing Materials Output Termination Transmitter Resolution Accuracy Plastic and Standard Alloy Units +300°F (149°C) Polysulfone Cable Mini Alloys +300°F (149°C) Standard Alloy and High Performance Alloy Units +750°F (399°C) 316 Stainless Steel Junction Box (Feralloy Iron) 3/8˝ (9. Low Temperature Transmitter Explosion-Proof Transmitter Low Temperature Transmitter Explosion-Proof Transmitter Explosion-Proof / High Temperature Transmitter LEVEL INDICATORS – VISUAL 1/2˝ NPT 1/2˝ NPT Compatible SureSite Types Operating Temperature. schedule your next inventory.GemsSensors. You can have visual indication and a continuous electrical output too without additional tank penetrations. . or other appropriate. Use them to know what’s in your tank remotely. Visit www. add one of these transmitters. D-16 Intrinsic Safety Operation is intrinsically safe when transmitters are properly connected with a Gems. D-12 and D-15). send the signal to your controller. D-9. Max. These transmitters are compatible with the readout displays at the end of this Section (D-24 to D-26) or can interface directly to your equipment by specifying the appropriate output. Junction boxes with terminal blocks are also on Page D-17.com for most current information.5 mm) Signal Conditioned Modules Gems offers a variety of electrical Junction Boxes with built-in Signal Conditioners to increase the versatility of SureSite Indicators. zener barrier in Section L.5 mm) 3/8˝ (9. the source voltage value used should be above the minimum load line for the related loop resistance.007%/°C) To within ±1% of 16 mA Power Supply Module Input Power 115 VAC. DC SOURCE VOLTAGE (+VA) 40 30 20 10 AREA OF OPERATION How To Order Select Part Number based on Output Signal desired and SureSite Indicator being used. Operates on 115 VAC or 230 VAC inputs to supply a regulated 24 VDC to the signal conditioned transmitter where external VDC power is not available. (Total loop resistance = the sum of the DC termination resistance plus loop resistance. 0-12 VDC and 4-20 mA Outputs Provide signal conditioning as an integral part of the SureSite® Level Indicators  Stem Mounted  Panel Mounted  J-Box Enclosed J-Box Enclosure Gems signal conditioners provide outputs for direct connection to a wide range of instrumentation.) 4-20 mA Types +5°F to +160°F (-15°C to +71°C) -40°F to +212°F (-40°C to +100°C) ±0. D-17 LEVEL INDICATORS – VISUAL . max.) For optimum operation. Maximum Load: 70 mA. No intermediate receiver is required. DC signal converters (See chart at right) can be determined for a given total loop resistance from the graph shown. multi-tank complexes.SURESITE® LEVEL INDICATORS Signal Conditioning Modules. 60 Hz 230 VAC. Panel Mounted (Plug Base) Specifications (Not included in table below) Operating Temperature Storage Temperature Output Temperature Coefficient (% of full scale. which is a function of source voltage (+VA) and total loop resistance. Units with 4-20 mA outputs are particularly well suited for instrumentation control loops. They are ideal for large.GemsSensors.com for most current information. 0-5 VDC. Electrical Termination Method Output Signal 0-5 VDC Junction Box 4-20 mA Panel Mount with Plug-In Base = Stock item Input Voltage 8-24 VDC 10-40 VDC 10-40 VDC Module Part Numbers For: SureSite SureSite Low Temperature High Temperature 86156 85997 86158 112300 52536 52537 152800 112300 200 400 600 800 1000 TOTAL LOOP RESISTANCE (OHMS) 1200 0-12 VDC 15-30 VDC 4-20 mA Visit www. 60 Hz Part Number 52560 52570 Excitation Required for Transmitters using 4-20 mA Signal Conditioners The minimum excitation required for operation of transmitters with 4-20 mA.00388%/°F (±0. 120 VAC DTDT.com for most current information. Specify the Part Number and quantity of switches desired on Product Check List. STANDARD MODULE Lead Wires Down FLAG ASSEMBLY How To Order Switch modules can be added to any SureSite Indicator at any time.These switch modules can be rendered intrinsically safe with the use of GEMS SAFE-PAKS® and Zener Barriers. They mount alongside the flag assembly for easy viewing. .or Intermediate-Level Alarms or Control Logic Standard Switch Modules High Temperature Switch Module Explosion-Proof Switch Module 3. and are operated by the SureSite float. Switch opens on rising level and remains open until closed by falling level. Low. centimeter. 24 VDC Rating* 20VA 20VA 20VA 20VA 20VA 10A 10A Alloy & ASME SureSite 86435 83150 84320 83130 84330 83100 83110 Mini SureSite 86567 83150-M 84320-M 83130-M 84330-M 83100-M 83110-M Plastic SureSite 80469 83150-P 84320-P 83130-P 84330-P 83100-P 83110-P = Stock item Switches mount opposite flags. For Intrinsic Safety. liters or percentage available. SWITCH ACTUATION POINTS HIGH TEMP MODULE SURESITE HOUSING * See “Electrical Data” on Page X-5 for more information. Part Numbers – Based on SureSite Version Switch Type Standard Hi-Temp ExplosionProof SPST SPST SPDT SPST SPDT DPDT. • Markings: Feet and Inches Inches Metric (Decameter.9°C) Connection: 1/4˝ FNPT • • • • Withstands Temperatures of 750°F (399°C) 316 Stainless Steel Construction 1/2˝ MNPT Conn. Visit www..75˝ (95 mm) DIAMETER • • • • • CSA Approved Includes Stainless Steel Mounting Clamp Polysulfone Housing Withstands Temperatures to 300°F (148. CSA. 6˝ (152 mm) Approx.. FM Approved Withstands Temperatures of 750°F (399°C) J-Box Terminated Stainless Steel Construction Includes Stainless Steel Mounting Clamp LEVEL INDICATORS – VISUAL D-18 Switch Logic (All Models) Lead Wires Up Switch closes on rising level and remains closed until opened by falling level.5˝ (89 mm) Approx.5˝ and 3˝ wide versions. 6˝ (152 mm) 1/2˝ NPT 3. • Available in 1. Mounting Switches mount opposite flags (180°) and may be positioned next to each other for multiple actuation requirements. Indicating Scales These optional stainless steel indicating scales provide a numerical readout of the liquid level in addition to the flag indication.Switch Modules Provide High-. See Section L. millimeter) Custom marked graduations such as gallons.GemsSensors. Includes Stainless Steel Mounting Clamp • • • • • UL. ... DIPTAPE Indicators are ideal for quick.............DIpTApE INDICATORS DIPTAPE Visual Level Indicators – Manually Operated These manually-operated indicators are compact and completely selfcontained. or undesirable... 24 Typical Application Refillable.......GemsSensors....... Custom-configurable DIPTAPE Indicators described on the following pages are available in a broad range of materials and mounting types in lengths to six feet (1..... The indicator is then lowered back inside the unit for storage and is protected by the screw type cap when not in use. Level readout is obtained by simply removing the protective cap atop the unit and lifting the calibrated indicator (within the unit) until magnetic interlock with the float is felt........... D-19 LEVEL INDICATORS – VISUAL ... so the readout tape is always clean and readable. inside the storage vessel...... consult factory............. portable chemical tanks are monitored and exchanged when empty...... D-21 Alloy Versions .. especially in remote areas where power is unavailable...... The indicator is held at this point and level is read where the calibration aligns with the top of the mounting.... Only the float and stem contact the liquid.. Plus....... General Operating Principle A magnet-equipped float moves with liquid level along the unit stem....... their rugged construction stands up to the rigors of transportation....... They need no electricity to provide continuous indication of liquid level in storage tanks and vessels. For lengths six to ten feet......8 m)..com for most current information.......... FULL EMPTY Contents Page Start All-PVC Versions . periodic readouts that are accurate to 1/16 inch or 1 mm. D-22 Visit www................. D-20 Engineered Plastic Versions ... DIPTAPE Indicators maintain a “closed” system on tanks or drums containing environmentally hazardous liquids and vapors.... 1 mm) DIA. .2 cm to 182. Mounting Types Type 3 2" NPT Type 4 3" -150# ANSI Flange “B” Dimension (Length Overall): Indicating Length +1-7/8˝ (47.P.540 DIA. 1-1/2" (38.4 mm) HIGHEST LEVEL INDICATED HIGHEST LEVEL INDICATED 1/4" I.2 mm) 1-1/2" (38.1 mm) DIA.GemsSensors.6 mm) PROTECTIVE CAP CALIBRATED INDICATOR PARTIALLY EXTENDED 1 1/2" (38.1 mm) LEVEL INDICATORS – VISUAL Stem. Indication Markings *For longer lengths.S. Float and Mounting Material Min. To specify DIPTAPE Level Indicators. 2. Indicating Length* Std. 3. Liquid Specific Gravity Operating Temperatures Operating Pressure.7°C to 60°C) 15 psi (1 bar) 6" to 72" (15. Max. 1/4" (6. Ideal for chemical storage tanks. Use the product information in this section to make your selections on the Check List. our all-PVC DIPTAPE Indicators provide one of your best values for liquid level monitoring. 1-5/8" (41. start by photocopying the OrderIt! Product Check List located on Page D-23.com for most current information. STEM INDICATING LENGTH B 1-5/8" (41. Fax: 860-747-4244 D-20 Visit www.65 0°F to +140°F (-17. Easy online ordering too! 1.S.9 cm) 1/16" or 1 mm increments Ordering Is Easy 1. These light duty versions are recommended for use in calm liquids and ambient temperature and pressure levels. .All-PVC Versions Are Economical for Light Duty  Temperatures to 140°F (60°C)  Pressures to 15 PSI (1 bar) Max.P. STEM INDICATING LENGTH B 1/4" I. please consult factory. Ordering is Easy! See Page D-23. Please use a separate Check List for each unique configuration. Fax your completed OrderIt! Check List to Gems for a price quotation.540 DIA.2 mm) PVC 0. See Engineered Plastic versions on the next page for enhanced performance characteristics. . . (6. (28. Float Types Float Material Part Number Min.840 DIA. STEM INDICATING LENGTH B 1/2˝ I.S. review the alloy versions on next page. large floats and 1/2 inch IPS stems. **Dimensions listed below. please consult factory.3 mm) A** 3˝ (76.S.4°C to +60°C) 50 psi (3.GemsSensors. Liquid Specific Gravity Operating Temperatures Operating Pressure. PROTECTIVE CAP Type B 3" NPT CALIBRATED INDICATOR PARTIALLY EXTENDED Type C 3" -150# ANSI Flange C** C** 1/4˝ REF. under “Float Types.4 mm) 15/16˝ (23. D-21 LEVEL INDICATORS – VISUAL 1-1/8˝ REF. Mounting Types “B” Dimension (Length Overall): Indicating Length + A + C Note: Dimensions “A” and “C” are dependent on float selected.P.” PVC. Indication Markings *For longer lengths. “A” Dimension (From Mounting Types) “C” Dimension (From Mounting Types) 1-3/4˝ (44. Ordering is Easy! See Page D-23. these DIPTAPE Indicators provide rugged durability in almost any chemical tank.com for most current information. Stem and Mounting Material Indicating Length* Std. See Float Types below.2 cm to 182.46 +40°F to +140°F (+4. Easy online ordering too! 1.65 Polypropylene 73742 0. Max.4 mm) HIGHEST LEVEL INDICATED 1/2˝ I.9 cm) 1/16" or 1 mm increments 2.6 mm) 1/2˝ (12. PVDF or Polypropylene 6" to 72" (15.3 mm) A** 3˝ (76.4 bar) 1-3/8˝ (34. 2-3/8˝ (60.P.6 mm) HIGHEST LEVEL INDICATED .83 Visit www.7 mm) PVDF 73740 0. For higher temperature and pressure capability. STEM INDICATING LENGTH B 2-3/8˝ (60.3 mm) 2-3/16˝ (55.840 DIA.2 mm) DIA. . engineered plastic materials.2 mm) DIA.4 bar) With a choice of three highly resistive.8 mm) PVC 71741 0.DIpTApE INDICATORS Engineered Plastic Versions Offer Best Chemical Resistance  Temperatures to 140°F (60°C)  Pressures to 50 PSI (3.9 mm) 1-5/16˝ (33. STEM INDICATING LENGTH 1/2" (12. Ordering is Easy! See Page D-23.GemsSensors. please contact factory.362 ±.7 mm) DIA.D.4 mm) 0. 1.015˝ (31. 1/2" (12.555˝ MIN. Float Types Buna N* 2˝ (50.6 mm) 2-1/16˝ (52. STEM B INDICATING LENGTH B BUNA N FLOAT SHOWN A* 1-7/8" (47.3 mm) D-22 Visit www. 73710 0. REF.S.45 Oil: -40°F to +230°F (-40°C to +110°C) Water: to 180°F (+82.7 mm) 11/16˝ (17. Brass or 316 Stainless Steel 1/16" or 1 mm increments 316 Stainless Steel Stem with Carbon Steel or 316 Stainless Steel Flange 6" to 72" (15.2 mm) 1. Max.2°C) 300 psi (21 bar) max.251˝ 1. (47.2 cm to 182. Mounting Types “B” Dimension (Length Overall): Indicating Length + A + C Note: Dimensions “C” and “A” are dependent on float selected.306˝ (33.8 mm) (34. (14 mm) 1-13/16˝ (46.com for most current information. I.7 mm) DIA. FLOAT SHOWN A* 2-1/16" (52.63˝ MAX . Select these units for best temperature and pressure capabilities. See Float Types below. PROTECTIVE CAP Type 3 2" NPT Type 4 3" -150# ANSI Flange CALIBRATED INDICATOR PARTIALLY EXTENDED C* HIGHEST LEVEL INDICATED C* HIGHEST LEVEL INDICATED LEVEL INDICATORS – VISUAL Stem and Mounting Material Indicating Length** Std.6 mm) DIA.3 mm) Stainless Steel 1. @ 77°F (25°C) 1-1/4˝ (31. under “Float Types.9 cm) 2. OVER WELD 1.5 mm) 73709 0.8 mm) 2-3/32˝ (53.9 mm) 3/4˝ (19.67 -40°F to +300°F (-40°C to +148.4 mm) DIA. Indication Markings * Dimensions listed below.8°C) 750 psi (52 bar) Mounting Type 3 150 psi (10 bar) Mounting Type 4 1-3/8˝ (34.DIPTAPE™ Indicators – Alloy Versions  Temperatures to 300°F (148°C)  Pressures to 750 PSI (52 bar) Rugged brass or stainless steel units are ideal for use in water and oils.” ** For longer lengths.D. S.67 -40°F to +220°F (-40°C to +104°C) 150 psi (10 bar) 1˝ (25. Easy online ordering too! 1. Liquid Specific Gravity Operating Temperatures Operating Pressure.6 mm) Float Part Number Min. “A” Dimension (From Mounting Types) “C” Dimension (From Mounting Types) *Other Wetted Material: Hysol. .DIA.4 mm) 9/16˝ (14.523˝ O.05 mm) 138935 0.0 mm) 1-7/8˝ DIA. O.747. 1. Specific Gravity: Minimum ______ Maximum _____________ 5.com for most current information.# ______ Name __________________________________________ Company ________________________________________ Street __________________________________________ City_______________________ State ____ Zip__________ Phone ( _____ ) __________________________________ Fax ( _____ ) _____________________________________ Quantity Needed ____________ Photocopy This Form Use one form for each product type you are selecting.This is a  Request for a Quote  Order P. Pressure: Minimum_________ psig Maximum __________ psig 3.3000 fax 860. Tank Depth: __________________________________________ 1. Gems Sensors & Controls One Cowles Road Plainville.4244 www. Other lengths. indicating length 72˝. Stem Length (Length Overall) “B” Max. Dimension B = _______________  centimeters  inches Please contact Gems for any configuration or special requirements not covered on this form. CT 06062-1198 Sensors & Controls tel 860. Date Required ____/____/_____ Shipping Method:____________ Partials Accepted:  Yes  No DIPTAPE Level Indicators Application Environment Conditions This information is essential to the accurate and proper operation of your DipTape Level Indicators. Tank Material: ________________________________________ 7. Temperature: Minimum ______ °F Maximum ____________°F 4.gemssensors.com for RFQ. 800-378-1600 Quote: $ _______________ Date Quoted:____/____/____ Visit www. Float Types:  PVC  Buna N  PVDF  Polypropylene  316 Stainless Steel 4. Mounting Type:  Type B  Type 3  Type C  Type 4 2. consult factory.GemsSensors.747. This form may also be completed online at gemssensors. Viscosity: _________________ SSU 6.com Diptape LeveL inDicators D-23   Product Check List . Material:  PVC  PVDF  Polypropylene  Brass  316 Stainless Steel Flange – Alloy Version:  316 Stainless Steel  Carbon Steel 3. Liquid Media: _________________________________________ 2. Please complete fully and accurately. Those receivers designed for the XM-Series transmitters also include a power supply for the transmitter. ALARM ACKNOWLEDGE LO HI GAL X 10 5 25 50 75 PERCENT 100 3-Digit Level Cube Receivers LEVEL CUBE SOLAR RECEIVER RE163000 DIGITAL RECEIVERS CALIBRATION ACCESS GEMS MODEL 163000 DIGITAL RECEIVER POWER CABLE TRANSMITTER Digital Bargraph Receivers LEVEL INDICATORS – VISUAL D-24 TANK Level Cube with 1/2˝ NPT shown mounted directly on GEMS XM-Series Transmitter. i. *Mounting Definitions: Wall: Mounted onto a surface. Transmitter: Mounted directly to the top of the transmitter. etc. with the standard designs shown in this catalog. Panel: Mounted into. Our experienced engineering staff will custom design receivers to suit your application. Visit www. 20-50 VDC Compatible GEMS Products XM-Series (1/4˝ or 1/2˝ Resolution). and all of the calibration adjustments for a complete Continuous Level Indication system. and approximately flush with. Or. bulkhead. . Solar 90-120 VAC. up to 100 feet from the transmitter. a surface through a cutout. they may be mounted remotely. GEMS doesn’t stop. Receivers 3-Digit Level Cube Receivers RE163000 Mounting* Wall or Transmitter Panel or Wall Alarm None 2 Alarm Operating Voltage 9V Battery. however. 9 VDC / 117 VAC. Pressure Transmitters These units feature a large 4-digit display and bright LED bargraph to visually clarify relative tank content level.e.GEMS Receivers Tell You What Your Sensors Already Know GEMS Receivers house a numerical digital readout..GemsSensors. Don’t hesitate to contact us about your special requirements. SureSite Transmitters. wall. deck. Selector Guide The Selector Guide below lists standard GEMS Receivers and the transmitter series with which they are normally configured.com for most current information. and SureSite Transmitters All Continuous Transmitters. 22 AWG. watertight* 100 feet. Groups C & D Notes: 1. These units are not watertight.. NEMA-4X. Class I. RUBBER SHIELDED CABLE 26" L. NO. On/Off switch available 2. SIL. +23°F to 131°F (-5°C to +55°C) ± 2% GEMS ® 3-1/8" (79. transpose red and black connections.4 mm) 3-1/8" (79. Visit www. 9-V Alkaline Battery Powered Units: Two batteries (supplied) are snapped into terminals in Cube.. SIL.com for most current information. NO.8 mm) 2-9/64" * (54. Part Number 119218. Max. 22 AWG. Typical Wiring Diagram RED RED WHITE BLACK LEVEL CUBE WHITE BLACK How To Order – Standard Models Style 9-V Battery 9 VDC / 117 VAC Solar Mounting Cable Output 1/2˝ NPT Cable Output 1/2˝ NPT Cable Output 1/2˝ NPT Part Number 118600 119250 118620 119270 118610 119260 Note: For ullage indication. The indicating range and decimal point location on the display are quickly and easily selectable with the readout plainly visible. D-25 LEVEL INDICATORS – VISUAL AC ADAPTER2 Dimensions Cable Output Versions 3-7/32" (81.8 mm) 3-7/32" (81. place shunt over right two pins of any set.GemsSensors. 9 VDC/117 VAC Powered Units: Power is supplied from AC adapter.8 mm) only.4 mm) FM Approved.4 mm) GEMS® 1/2" NPT 1/2" NPT *Except for 9 VDC/117 VAC Powered Units which are not watertight. * P/N 118600 9-V Battery = 3-11/32˝ (84. A plug. 1/2˝ NPT Versions 3-7/32" (81. Results are observed on the front display. continuous 3-digit readout of liquid level. is available for use where 7-VDC power is supplied by customer.4 mm) .8 mm) 3-11/32" (84. low-cost Level Cubes provide accurate. 3.4 mm) 3-1/8" (79.RECEIVERS 3-Digit Level Cube Receivers For use with GEMS Transmitters and SureSite® Transmitters. Intrinsically Safe. Solar-Powered Units: Sunlight or a flashlight beam directed on a solar cell in the front cover is all that’s needed to operate.8 mm) 3-7/32" (81. NPT or Cable Mounted 3 Power Choices with NPT or Cable Mounted 9-V Battery Powered 9 VDC/117 VAC Powered Solar-Powered GEMS® GEMS® SOLAR CELL Part Numbers: 118600—Cable Output 119250—1/2˝ NPT Part Numbers: 118620—Cable Output 119270—1/2˝ NPT Part Numbers: 118610—Cable Output 119260—1/2˝ NPT — GEMS ® GEMS® 3-1/8" (79. Division 1.8 mm) Specifications Housing Material Cable Distance from Transmitter Operating Temperature Accuracy Polycarbonate. These compact.8 mm) 3-11/32" (84. For no decimal. INSIDE OF COVER BLACK SHUNT 3-PIN SET BOTTOM ADJUST POT SLIDE SWITCH FINE ADJUST POT COARSE ADJUST POT To position decimal point: Place black shunt over left two pins of proper 3-pin set for desired decimal in display.4 mm) 2-9/64" * (54. RUBBER SHIELDED CABLE 26" L. Easy to Adjust and Calibrate Adjustments must be performed with cover removed (see illustration) and power applied. Labels are supplied and user applied.Pounds of liquid in a spherical tank.com for most current information. The numeric portion is a 1/2˝ 4-digit display that provides detailed quantification of tank contents. Examples of Non-Linear Display Values. Liters. Pounds. LEVEL INDICATORS – VISUAL D-26 GAL X 10 5 25 50 75 PERCENT 100 Enclosed Versions CALIBRATION ACCESS PRESS GEMS MODEL 163000 DIGITAL RECEIVER Imo Industries Inc. Linearization Certain tanks.Digital Bargraph Display Receivers 163000 Series Gems Digital Bargraph Receivers improve the way you are able to visualize the data being received from your liquid level transmitters. Gallons. ALARM ACKNOWLEDGE LO HI Panel Mounted Versions 2 Independent Alarms with adjustable time delays.GemsSensors. Proportional Voltage*. 1. capacity curve and/or tank drawing for linearization of the digital bar graph display receiver. 3. the Gems Bargraph Receiver features two independent alarms with adjustable time delays. Gems Sensors Division Plainville. In these cases this receiver may be linearized according to your tank parameters so that the correct volume is displayed. 5. 2.Gallons in a cylindrical tank laying down. LED Bargraph represents percentage of tank contents. Note: Customer alarms (High & Low) set upon request. Serial ± 1. 10 amp auxiliary dry contacts and easy user set-up. . etc. Dry Contact 0000 to 9999 * Proportional voltage as produced by the non-signal conditioned Gems Liquid Level Transmitters (Section H and SureSite Transmitters (Section G). Large 4 Digit Numerical Display. These 8 lines approximate the curve of the non-linear tank. these receivers are a blessing.Cubic meters in a conical shaped tank. See “Linearization” below.Gallons in a non-linear shaped tank. cubic inches. Example of units measured: Gallons. inches. like a sphere or a cylinder laying on its side. Any units may be displayed by the receiver. In addition to the dual visual displays. such as a sphere or a cylinder laying on its side. 4. CT 06062-1198 Tel. Labels are supplied and user applied. Visit www. Touch to acknowledge alarm activation. IMPORTANT: Customer must supply a sounding table.. Specification Input Signal Accuracy Over Given Range Operating Voltage Operating Temperature Alarm Contacts. These new receivers display liquid level information in digital numerals in conjunction with a 0-100% LED bargraph readout.0% 24VDC or 115VAC -4°F to +140°F (-20°C to +60°C) 10Amp. Load Digital Readout 4-20mA. The receiver is available in component form for mounting into custom enclosures or panels. while the bright LED bargraph represents the tank contents as a bar length relative to the percentage of fluid volume within the tank. They can be calibrated easily so that the digital and bargraph displays will indicate accurate content information for “odd” shape tanks. If you have a non-linear tank. liters and etc. The receiver uses a scheme where 9 points or 8 straight lines are used to calculate the numbers to be displayed. are considered “NonLinear” in terms of volume versus tank height.Gallons in a spherical tank. tons. 860-747-3000 Calibration conveniently accessible from front of panel (access plate is supplied loose in a cloth bag along with labels). or housed within a NEMA 4X enclosure. GemsSensors. Gems Sensors Division Plainville. Input Power Input/Output Signals Input Transmitter* Serial 24 VDC Transmitter* 4-20mA Transmitter* Serial 115 VAC Transmitter* 4-20mA Output None None 4-20mA 4-20mA None None None 4-20mA 4-20mA None Part Number NEMA 4X Panel Mount Fiberglass Enclosed 170680-0100 170681-0100 170682-0100 170683-0100 170684-0100 170685-0100 170686-0100 170687-0100 170688-0100 170689-0100 170690-0100 170691-0100 170692-0100 170693-0100 170694-0100 170695-0100 170696-0100 170697-0100 170698-0100 170699-0100 Gems Liquid Level Transmitter * Proportional voltage as produced by the non-signal conditioned Gems Liquid Level Transmitters (Sections C) and SureSite Transmitters (Section D).Standard Select reciever type by Part Number based on Input Power and Input/Output Signals required. Handling Precautions Required.com for most current information.. When used in conjunction with RE-163000. THRU 2.RECEIVERS Dimensions Panel Mounting Recievers 3" ALARM ACKNOWLEDGE LO HI .. CT 06062-1198 Tel. Static Sensitive.312" 5 5 3/4" 25 50 75 PERCENT 100 CALIBRATION ACCESS GEMS MODEL 163000 DIGITAL RECEIVER Imo Industries Inc.. Gems Sensors Division Plainville. no additional signal conditioning required.281 THRU CUSTOMER’S MOUNTING SURFACE (4X) 6˝ REF. CT 06062-1198 Tel. 860-747-3000 GEMS MODEL 163000 DIGITAL RECEIVER Imo Industries Inc. 860-747-3000 PRESS 2 3/4" CUSTOMER'S MOUNTING SURFACE 3 13/32" REF. CT 06062-1198 Tel.156 DIA. MOUNTING HOLES (4X) FOR 1/4˝ BOLTS 0.562" 3/32" GAL X 10 7/32" 4 7/8" 5. Visit www. D-27 LEVEL INDICATORS – VISUAL PRESS PRESS . 11-1/4˝ REF. 860-747-3000 163000 Series Digital Receiver Optional Zener Barrier (See Section N) 4-1/2˝ REF. NEMA 4X Enclosed Receivers Typical Installation ALARM ACKNOWLEDGE LO HI GAL X ALARM ACKNOWLEDGE LO HI 10 24 VDC or 115 VAC 5 25 50 75 PERCENT 100 GAL X 10 CALIBRATION ACCESS 100 5 25 50 75 PERCENT CALIBRATION ACCESS GEMS MODEL 163000 DIGITAL RECEIVER Imo Industries Inc. 4-1/2˝ REF. Gems Sensors Division Plainville. How To Order . .com for most current information.GemsSensors.NOTES LEVEL INDICATORS – VISUAL D-28 Visit www.
Copyright © 2024 DOKUMEN.SITE Inc.