W11.de Drywall Systems 2015-08 W11.de Knauf Metal Stud Partitions W111.de – Knauf Metal Stud Partition – Single metal stud frame, single-layer cladding W112.de – Knauf Metal Stud Partition – Single metal stud frame, double-layer cladding W113.de – Knauf Metal Stud Partition – Single metal stud frame, triple-layer cladding W115.de – Knauf Metal Stud Partition – Double metal stud frame, double-layer cladding W116.de – Knauf Metal Stud Partition – Double metal stud frame, single/double-layer cladding Note on English translation / Hinweise zur englischen Fassung This is a translation of the system catalogue valid in Germany. All stated details and properties are in compliance with the regulations of the German standards and building regulations. They are only applicable for the specified products, system components, application rules, and construction details in connection with the specifications of the respective certificates and approvals. Knauf Gips KG denies any liability for applications outside of Germany as this requires changes acc. to the respective national standards and buildingsound regulations. ■■Update: Fire protection, installation, technical data, partition heights Dies ist eine Übersetzung des in Deutschland gültigen Detailblattes. Alle angegebenen Werte und Eigenschaf■■New variants for partition wall breaks/tapers ten entsprechen den in Deutschland gültigen Normen und bauaufsichtlichen Regelungen. Sie gelten nur bei Verwendung der angegebenen Produkte, Systemkomponenten, Anwendungsregeln und Konstruktionsdetails in Verbindung mit den Vorgaben der bauaufsichtlichen Nachweise. Die Knauf Gips KG lehnt jegliche Haftung für Einsatz und Anwendung außerhalb Deutschlands ab, da in diesem Fall eine Anpassung an nationale Normen und bauaufsichtliche Regelungen notwendig ist. New Copyright by Knauf Gips KG W11.de Knauf Metal Stud Partitions Contents Page Basics Knauf boards, installation schemes for Knauf boards, fastening of the cladding Stud frame Certificates, notes, construction and assembly Fire protection, sound installation, technical data Upgrading existing walls (fire protection, sound insulation) Wall breaks (sound insulation) Connections to ceilings (fire protection) Installation of power sockets (fire protection, sound insulation) 3 6 7 8 18 20 22 23 Standard details W111.de Metal Stud Partition Single metal stud frame, single-layer cladding 24 W112.de Metal Stud Partition Single metal stud frame, double-layer cladding 25 W113.de Metal Stud Partition Single metal stud frame, triple-layer cladding 26 W115.de Metal Stud Partition Double metal stud frame, double-layer cladding 27 W116.de Installation Wall Double metal stud frame, single/double-layer cladding 28 W111.de to W116.de: Wall breaks, detached wall end, corners, connection to solid wall, T-junctions, movement joints, connection to floor, connection to ceiling Door openings, partition openings Curved partitions Partitions without connection to ceiling 29 Fixing loads, cantilever loads Material requirements Jointing, coatings and linings Sustainability, important notes 40 42 43 44 Connections to solid wall, board joints connections to ceiling, connections to floor Details The details are only represented in each case for the selected examples and can be used, if necessary, as a constructional solution for other partition systems. General 36 38 39 Notes on fire protection proofs The specifications marked with offer the user additional application options, which are not directly included in the Certificate of Usability. On the basis of our technical assessments, we assume that the marked design solutions can be assessed as a non-significant divergence. In this respect, according to our estimation, no approval is required in individual cases for these design solutions, but rather the Confirmation of Compliance and the non-significant divergence with a Declaration of Compliance from the manufacturer for the type and the professional installer undertaking the installation to be sufficient. We can provide the documentation on which this assessment is based, such as surveyors' reports or technical assessments to you together with the Certificate of Usability on request. 2 As the “significant/non-significant” restrictions are not legally defined and their assessment can be interpreted differently by the respective building supervisory authorities, we recommend that a non-significant divergence be coordinated and authorised in advance in consultation between the persons responsible for fire protection and/or the relevant authorities. W11.de Knauf Metal Stud Partitions Knauf boards Knauf boards Extract from Knauf product range Board type Dimensions mm Thick- Width ness Short designation DIN EN Board edges Long edge Gypsum boards acc. to DIN 18180 and EN 520 Reaction to fire A2-s1,d0 (B) Knauf Bauplatte wallboard GKB 12.5 1250 GKB A GKBI 12.5 1250 GKBI H2 Feuerschutzplatte Knauf Piano fire-resistant board GKF 12.5 1250 GKF DF GKFI 12.5 1250 GKFI DFH2 GKF 15 1250 Knauf Feuerschutzplatte fire-resistant board 18 1250 GKFI 15 1250 GKFI Massivbauplatte solid board GKF 25 625 GKF DF GKFI 25 625 GKFI DFH2 Diamant GKFI Diamant GKFI Silentboard GKF 12.5 1250 15 1250 GKF DF Half-rounded tapered edge Half-rounded tapered edge Half-rounded tapered edge DFH2 Half-rounded tapered edge GKFI DFH2IR Half-rounded tapered edge 18 625 GKFI DFH2IR Half-rounded tapered edge 12.5 625 GKF DF Half-rounded tapered edge Gypsum boards acc. to DIN 18180 and EN 520 Comfortboard 231) GKB Reaction to fire D-s1,d0 12.5 1250 GKB D Half-rounded tapered edge Gypsum boards from reprocessing acc. to DIN 18180 and EN 14190 Horizonboard2) GKF 12.5 Reaction to fire A2-s1,d0 (C.2) 1250 GKF Procedure a/b Tapered long edge Gypsum boards acc. to EN 15283‑1 Fireboard GM-F Reaction to fire A1 15 1250 20 1250 25 1250 30 1250 – GM-F Square edge Gypsum boards acc. to DIN EN 15283‑1 Drystar Board3) GM‑FH1IR Reaction to fire A2-s1,d0 (B) 12.5 1250 – GM‑FH1IR Tapered long edge 1) Application in constructions with demands made on the fire resistance on request 2) Application as top cladding layer possible analogue to Knauf Piano GKF fire-resistant board 3) Fire protection, sound insulation and application acc. to brochure Tro96.de Knauf Drystar ■■ GKBI/GKFI: Gypsum core with additional special impregnation against the absorption of moisture. Board suitable for high humidity areas. ■■ Drystar Board is suitable for use in damp and wet rooms ►► Also refer to the Product Data Sheets of the Knauf boards (available at: www.knauf.de) 3 W11.de Knauf Metal Stud Partitions Installation schemes for Knauf boards (Schematic drawing examples) Board layers vertical Board layers horizontal + vertical Board width: 1250 mm Stud spacing: 625 mm Long edge Long edge Front edge Front edge Long edge Board width: 625 mm (lower layer horizontal) Board width: 1250 mm (upper layer vertical) Stud spacing: 625 mm Front edge ■■ Stagger long edge joints by 625 mm (one stud spacing) ■■ If floor-to-ceiling boards are not used, stagger the front edge joints in a cladding layer ▪▪ Without fire protection: ≥ 400 mm ▪▪ With fire protection: single-layer ≥ 1000 mm; multi-layer ≥ 500 mm ■■ Stagger the front edge joints between board layers in case of multilayer cladding. ■■ Board joints of cladding on opposing sides must also be staggered to one another. Lower layer: ■■ Front edge joints must be staggered by at least one stud spacing. ■■ Recommendation: Board length 2500 mm Upper layer: ■■ If floor-to-ceiling boards are not used, stagger the front edge joints. ▪▪ Without fire protection: ≥ 400 mm ▪▪ With fire resistance: ≥ 500 mm Offset between lower and upper layer: ■■ Stagger the board joints of the upper layer by approx 312.5 mm to the board joints of the lower layer. Offset of cladding on opposing sides: ■■ Board joints must also be staggered to one another. Horizontal board layer Board layers horizontal (e.g. W116.de) Board width: 625 mm Stud spacing: 625 mm Front edge Front edge Board width: 1250 mm Stud spacing: 625 mm Long edge Long edge ■■ Recommendation: Board length 2500 mm ■■ Front edge joints must be staggered by at least one stud spacing. ■■ Stagger the long joints between the cladding layers by at least half a board width. ■■ Board joints of cladding on opposing sides must also be staggered to one another. 4 ■■ Recommendation: Board length 2500 mm ■■ Front edge joints must be staggered by at least one stud spacing. ■■ Stagger the long joints between the cladding layers by at least half a board width. ■■ Board joints of cladding on opposing sides must also be staggered to one another. Dimensions in mm Maximum fastener spacings.9x35 + 3.9x33 – XTB 3.9x55 TB 3.5x25 TN 3.9x23 + 3.5x35 XTN 3.g.5x55 – TB 3.5x45 + 3. board width 1250 mm ■■ Lower board layer screw fastened (observe the reduced screw spacing) ■■ Observe the reduced partition heights (see pages 11 and 13) ■■ Observe the reduced fixing loads/cantilever load (see pages 40 and 41) ■■ Do not staple in the studs ■■ Curved Knauf boards may not be stapled. ■■ Steel staples compliant to DIN 18182-2: e.9x55 + XTB 3.9x551) TB 3.5x35 + 3.5 25 + 12.5x45 1) Combined cladding (Knauf boards + Diamant) ■■ Diamant screws must always be used for Diamant.5x45 + 3.25 mm Drywall screws Diamant screws Thickness in mm TN XTN TB XTB 12.5x25 – + XTB 3.5x25 + 3. Maximum fastener spacings.9x23 TB 3.W11.5 TN 3.5x25 + 3. all board layers fastened to frame with screws Cladding Board layer Board width 1st layer vertical horizontal 1250 12502) 625 2nd layer vertical horizontal 1250 12502) 625 3rd layer vertical horizontal 1250 1250 625 1 layer 250 – 200 – – – – – – 2 layers 750 610 600 250 250 200 – – – 3 layers 750 – 600 500 – 300 250 – 2003) ≥ 10 mm – edge covered with board liner ≥ 15 mm – cut edge 2) System W116. uppermost board layer stapled to the board layer below it Cladding 1st layer 2nd layer 3rd layer 2 layers 250 (screwed) 80 (stapled) – 3 layers 750 (screwed) 250 (screwed) 80 (stapled) Dimensions in mm ■■ Improved sound insulation by stapled top layer ■■ Staples can only be used exclusively on Diamant ■■ Vertical board layer. 15 mm cut edge).5x25 XTN 3.9x38 + 3.9x381) TN 3.5x25 + 3.5x25 + 3.5x55 + XTB 3.9x35 18 – XTN 3.9x35 15 – XTN 3.9x33 – XTB 3.de Knauf Metal Stud Partitions Fastening of the cladding (scheme drawings) Fastening of the cladding to the stud frame with Knauf screws Cladding Dimensions in mm Metal stud frame (Penetration ≥ 10 mm) Metal gauge s ≤ 0.9x551) TN 3.5x25 + 3.9x38 TB 3. Expanding staples from Haubold or Poppers-Senco Staple length = 2 board layers minus 2 mm 80 80 80 80 Board joint – "Non-supported joint" Board joint – field studs 80 80 80 160 80 Field studs 80 80 Perimeter studs 5 .9x35 + 3.5x25 + 3.9x23 + 3.9x55 + 3.9x35 TN 3.5x35 + 3.de 3) Upgrade with Silentboard ■■ Arrangement of screws for optimum sound insulation with minimum spacing from edge (10 mm edge covered with board liner.5 3x 12.9x551) TB 3.7 mm < s ≤ 2. Silentboard or Comfortboard 23 cladding.5x45 + TN 3.9x551) XTN 3.9x551) TB 3.5 + XTN 3.5x35 XTB 3.5x25 XTB 3.5x55 TN 3.9x55 2x 12.5x45 XTB 3. ■■ Arrange board joint on centre of profile flange.5x55 + XTN 3.5x35 XTN 3.7 mm Drywall screws Diamant screws Metal gauge 0. rivet.g. connected with additional UW runners.de Scheme drawings. door installation / sanistand installation H-punches.Metal stud frames Single metal stud frames W111.5 mm Copyright by Knauf Gips KG Option 4 2 UA profiles butt joint connected with additional UA profiles at the web side. crimp connect the studs ■ Option 4: Screw 2x per UA profile with M8 bolts or self-tapping screws ≥ Ø 4. o Overlap o o Stud extensions Knauf profiles . Profile 1 Profile 1 Web cut-out. interlaced with additional CW stud. with drawing on right ▪ Knauf profiles: CW 75 / CW 100 / CW 125 / CW 150 ▪ Cladding thickness per wall side: ≥ 12.5 mm ■ Knauf recommendation: Use floor-to-ceiling height UA profiles Extension to the fire protection certificate of usability ■ Design options 2 to 4 Prior consultation in acc. to page 2 recommended. screw or.de Knauf Metal Stud Partitions Metallständerwände Unterkonstruktion Stud frame Stud partitions . Additional UW runner Additional UA profile Profile 2 Profile 2 For cable penetrations in Knauf CW studs ≤ b ≥ 2x b b ≥ 2x b ≥1 0 ≤b -20 ≥1 0 ≥ ≤ 2x b b ■ Large number of smaller openings possible on request ■ The openings can be provided in addition to the usual factory made H punches ■ Web cut-outs for UA profiles on request For load-bearing UA profiles e. Stud 1 Crimping pliers for crimp connection Stud 2 Stud 2 Option 3 2 CW studs or 2 UA profiles butt joint connected.de / W113. if possible.W11. on-site 6 Additional stud o CW / UA 100 Stud 1 o ≥ 750 mm o CW / UA 75 o ≥ 500 mm Option 2 2 CW studs butt joint connected. factory-made ≤b ■ H web cut-outs ▪ Web cut-outs: max.de Knauf stud CW 50 CW 75 CW 100 CW 125 CW 150 Double metal stud frames W116. o CW / UA 50 Option 1 2 CW studs interlaced as a box. dimensions in mm Double metal stud frames W115.de / W112.de Knauf stud CW 50 CW 75 CW 100 Knauf stud CW 50 CW 75 CW 100 Decoupled with insulation strips Linked with board strips Knauf UW runner Knauf UW runner Knauf UW runner Vertical stud extensions ≥ 1000 mm CW / UA 125 ≥ 1250 mm CW / UA 150 ≥ 1500 mm ■ Stagger the stud joints vertically (alternating on upper and lower partition half) ■ Options 1 to 3: In overlapping section. 2 per metal stud ▪ Observe the dimensions in acc. R = calculation value of the weighted apparent sound reduction index without flanking paths ■■ Reinforcing and supporting components must feature the same fire resistance class as a minimum requirement. office and hospital rooms including corridors and halls or similar. 7 . Anchor wall perimeter runners with suitable dowels to flanking walls. e. school classrooms. supplement 1. metal stud partitions.de Knauf Security Engineering (German only). e. ■■ Stagger the board joints according to the installation schemes on page 4. ■■ Constructions acc.de W113. In case of sound insulation requirements. Fire protection ■■ Cable and pipe penetrations must be implemented in accordance with Knauf Fire Protection folder BS1.g. auditoria. the System W118. porous sealant strips such as sealing tape are usually not suitable in this case. exhibition halls and sales rooms as well as rooms with floor height difference of ≥ 1 m (protection against falling). Movement joints are to be installed every 15 m on continuous partitions. Solid flanking constructional components: Knauf Drehstiftdübel nailable plugs with masonry or Knauf Deckennagel ceiling steel dowels with reinforced concrete. ▪▪ Installation zone 2: Partitions in rooms where large numbers of persons gather. The stud construction is connected all around to the flanking constructional components. Anti-burglary protection ■■ Should there be demands made on antiburglary protection with party walls. Floor-to-ceiling Knauf boards are preferred for vertical cladding. ■■ Place the CW studs into the UW runners arranged along the length and align them. ■■ If a deflection of the ceiling ≥ 10 mm can be expected. sealing with permanently elastic sealant material (recommendation: Knauf Insulation LDS Solimur) may be necessary (see detail drawings). Insulation material can be fitted in the partition cavities (prior consultation is recommended with demands made on the fire resistance.de (German only).de ABP P-3310/563/07-MPA BS W116.de W112.de Knauf Metal Stud Partitions Certificates. Installation Stud frame ■■ Apply Trennwandkitt acoustical sealant (two strings) or sealing tape to rear side of runners for the connection of flanking constructional components.g. see page 2) as well as sanitary or electric built-ins. Knauf Universalschraube FN multi-purpose screws for wooden substrates. ■■ Apply the cladding vertically or horizontally to suit the system. meeting halls.g.de Knauf sound insulation proof L 037-01. install deflection heads. construction and assembly Proofs and certificates Knauf system Fire protection Sound insulation W111.de can be applied .2. ■■ Anchor wall perimeter runners to the floor and ceiling. to DIN 4103-1 ▪▪ Installation zone 1: Partitions in rooms where low numbers of persons gather. Use suitable spacings and fasteners in accordance with the tables of the corresponding systems. Cladding ■■ Fasten the cladding in accordance with the tables on page 5. ■■ For deflection heads.de W115. Ball impact safety Ball impact safety is provided with multi-layer cladding. hotels. etc. Construction Knauf Metal Stud Partitions consist of a metal stud frame configured as a single or double frame and both sides with single-layer or multiple-layer cladding made of Knauf boards. ■■ Use suitable fasteners. chapter 5.15 Statics (partition heights) Knauf boards Diamant ABP P-1402/354/12-MPA BS ABP P-1405/928/10-MPA BS DIN 18183-1 and/or Knauf recommendation Knauf recommendation DIN 18183-1 Knauf recommendation Details / notes ■■ Installation zones acc. see Brochure ST01. e. Movement joints Movement joints of the main structure should be integrated into the construction of the stud partitions.W11. to DIN 4102-4 are also possible using Knauf materials ■■ Sound insulation values only apply in conjunction with Knauf profiles when the recommended screw fastening is observed. Notes Sound insulation ■■ Avoid air leaks. seal carefully with Trennwandkitt acoustical sealant according to DIN 4109. notes. Non-solid flanking constructional components: Anchors specially suited for the building material. ■■ Requirements for the insulation layer: See the specifications for the respective system ■■ Rw. dwellings. g. sound installation.5 24 ■ 12. non-combustible ■■ Sound insulation requirement: 8 Mineral wool insulation layer acc.5 39 ■ F30 ■ 50 40 43 46 80 48 45 – ■ Stud spacing 57 100 a 12. from Knauf Insulation) ■■ Fire protection requirement: None ■■ Fire protection permissible: Mineral wool G .5 30 ■ 15 35 12.5 30 ■ 15 35 12.5 22 12.de Knauf Metal Stud Partitions Fire protection. technical data Technical and physical building data (Observe the notes/specifications on page 7) W111. to EN 29053: r ≥ 5 kPa • s/m² 52 .W111. ≥ 40 mm thick. to EN 13162.5 39 58 12.5 22 48 12. mineral wool insulation layer to EN 13162.5 24 ■ 12.5 30 ■ 15 25 ■ F30 ■ 75 60 46 49 105 51 – ■ 125 ■ F30 100 80 49 51 130 ■■ With fire resistance: Apply profile backing to front joints provided that no insulation material is installed ■■ With ceramic tiles: Minimum cladding Stud spacing 12. length-related flow resistance acc.5 24 ■ 12.5 22 12.5 mm Knauf boards ≤ 417 mm 15 mm Diamant ≤ 625 mm 18 mm Knauf boards ≤ 625 mm Requirements for the insulation layer: (Insulation materials e.5 39 42 – ■ 54 75 12.R dB Single metal stud frame. single-layer cladding ■ 12. kg/m² D mm Sound insulation Knauf CW Insulation layer Cavity Minimum thickness h mm mm Sound reduction index Rw.de Knauf Metal Stud Partitions Weight Wall Profile thickness Silentboard Without insulation layer Diamant Knauf Bauplate wallboard Fire resistance class t h D t Scheme drawings Massivbauplatte solid board Cladding per wall side Feuerschutzplatte Knauf Piano Knauf system Minimum thickness t mm approx. 65 5. fastener spacings Maximum permissible partition heights .5 mm Diamant 12.5 4.85 4.00 1000 1000 1000 500 > 3.5 8.00 417 3.00 312.30 5.00 to ≤ 6.00 10. 3 anchoring points).70 5.00 8.002) 500 – Verify the stability of the anchoring substrate and select suitable fasteners (for 2 kN/m) ≤ 3. Reduced maximum permissible spacings with edge fixing on floor constructions Supporting fastening of perimeter runner (UW) on floor constructions Anchoring substrate Fasteners Spacing of fasteners Pre-fab floor screeds Knauf Befestigungsschraube LG anchor halved – (multi-purpose screw) compared to above table Flowing screed Knauf Drehstiftdübel nailable plug halved – compared to above table Wooden planks / floorboards (screw-in depth 15 – 24 mm) Knauf Universalschraube FN multi-purpose screw halved – compared to above table 9 .35 5.5 4.85 5. max. Installation zones 1 and 2 Knauf profile Metal gauge 0.00 625 6.00 7.20 5.00 4.55 5.60 5.5 mm / 15 mm Without fire protection With fire protection Without fire protection With fire protection m m m m 625 3.00 7.00 4.00 4.5 6.00 1000 500 500 250 With fire protection 2) Observe max.00 a mm 1) Only for installation zone 1 Maximum permissible fastener spacings Supporting fastening of perimeter runner (UW) connection on basic floor and subceiling Partition height Knauf Deckennagel ceiling Knauf Drehstiftdübel Knauf Universalschraube FN multi-purpose screw steel dowels nailable plug (with wooden substrates screw-in depth > 24 mm.50 1000 500 500 250 > 6.00 9.6 mm CW 50 CW 75 CW 100 CW 125 CW 150 Stud spacing Knauf boards 12.00 417 7.00 4.00 9.00 8.65 5.95 5.00 625 5.201) 3.00 4.35 4.00 312.00 312.65 5.00 to ≤ 5.15 5.00 625 8.00 10.30 5.70 5. subceiling) (with reinforced concrete) 1x 1x 2x 1x m mm mm mm mm Without fire protection ≤ 3.60 5.95 5.00 312.75 4.00 6.00 312.00 4.85 4.50 to ≤ 12.80 5.20 5.35 5.40 5.de Knauf Metal Stud Partitions Partition heights.201) 4.85 3. partition heights ■■ Constructional anchoring of the wall connection profiles (CW) to the flanking walls at centres of 1000 mm (min.75 417 4.10 5.00 417 9.20 5.5 9.00 417 5.00 1000 1000 1000 500 > 3.00 4.W111.00 625 4. 5 50 ■ 2x 12.R dB 52 56 50 40 125 57 / 581) 62 63 100 65 53 55 125 57 75 60 150 59 / 611) 64 64 125 66 56 57 150 60 100 175 150 ■■ Always use Diamant as a covering layer with combined cladding ■■ F60 on request Requirements for the insulation layer: (Insulation materials e.5 55 ■ 25 + 12. sound installation.5 65 ■ 2x 12.5 71 ■ 12.5 75 2x 12.5 45 ■ 12.5 75 ■ ■ ■ Stud spacing ■ a F90 ■ ■ ■ ■ ■ F90 Minimum thickness t mm 2x 12.5 71 ■ 12. to page 2 54 100 1) Upper board layer stapled 10 Sound insulation Single metal stud frame.W112. from Knauf Insulation) ■■ Fire protection requirement: None ■■ Fire protection permissible: Mineral wool G (mineral wool insulation layer to EN 13162.5 45 ■ 12.5 50 ■ 2x 12.5 71 ■ 12.5 45 ■ 12.5 ■ ■ F30 Wall Profile thickness D mm ■ ■ Knauf CW Insulation layer Cavity Minimum thickness h mm mm Sound reduction index Rw.00 m (F90) ▪▪ Cladding with Knauf Bauplatten wallboard Prior consultation is recommended acc.5 55 ■ 25 + 12. length-related flow resistance acc.5 + 12. technical data Technical and physical building data (Observe the notes/specifications on page 7) W112.de Knauf Metal Stud Partitions Fire protection.5 65 ■ 2x 12.5 + 12.5 65 ■ 2x 12. to EN 29053: r ≥ 5 kPa • s/m² Extension to the fire protection certificate of usability ■■ When applying the insulation layer G in conjunction with ▪▪ Partition height > 5.5 40 2x 12.5 + 12.g. double-layer cladding ■ F30 Weight Without Insulation layer Diamant Knauf Bauplate wallboard Fire resistance class t h t D Scheme drawings Massivbauplatte solid board Cladding per wall side Feuerschutzplatte Knauf Piano Knauf system 80 61 / 621) 66 65 67 . non-combustible) ■■ Sound insulation requirement: Mineral wool insulation layer acc.5 40 2x 12.5 50 ■ 2x 12.5 75 2x 12.5 + 12. to EN 13162.de Knauf Metal Stud Partition F30 F90 Silentboard approx.5 + 12. kg/m² 40 2x 12.5 55 ■ ■ 25 + 12.5 + 12. 95 5.de Knauf Metal Stud Partitions Partition heights.00 10.00 9.5 mm m With fire protection F30 m F90 m Diamant 2x 12.05 5.W112.50 500 500 500 250 > 6.80 625 5.00 500 – Verify the stability of the anchoring substrate and select suitable fasteners (for 2 kN/m) ≤ 3.00 7.35 5.5 mm (all board layers screw fastened to stud frame) Without With fire protection fire protection F90 m m 625 4.50 to ≤ 7.00 7.00 12.50 8.00 1000 500 500 250 > 5.75 4.20 7.00 7.75 7.05 5.00 1000 1000 1000 500 > 3.50 to ≤ 12.00 11.00 7.00 4.40 5.80 7. Installation zones 1 and 2 Knauf profile Metal gauge 0.5 8. subceiling) (with reinforced concrete) 1x 1x 2x 1x m mm mm mm mm Without fire protection ≤ 3.35 5.00 4. fastener spacings Maximum permissible partition heights .15 5.00 7.05 7.00 417 10.00 500 – Verify the stability of the anchoring substrate and select suitable fasteners (for 2 kN/m) With fire protection ■■ Constructional anchoring of the wall connection profiles (CW) to the flanking walls at centres of 1000 mm (min.65 5.00 7.95 7.85 7.20 7.00 9.40 312.00 12.00 7.00 to ≤ 6.20 7.00 625 10. max.00 10.00 417 9.00 12. to system W111.00 4.00 5.00 4.00 417 5.5 6.00 Without fire protection a mm ■■ With stapled upper board layer: Partition heights acc.00 6.35 4.00 5.00 625 7.00 312.00 417 8.00 7.80 5.5 mm / Massivbauplatte solid board 25 mm + Diamant 12.30 7.00 to ≤ 5.00 625 9.75 417 4.50 1000 500 500 250 > 6.10 5.5 11.95 5.00 7.00 7.00 5.5 10.05 5.00 11.55 7.35 4. Reduced maximum permissible spacings with edge fixing on floor constructions Supporting fastening of perimeter runner (UW) on floor constructions Anchoring substrate Fasteners Spacing of fasteners Pre-fab floor screeds Knauf Befestigungsschraube LG anchor halved – (multi-purpose screw) compared to above table Flowing screed Knauf Drehstiftdübel nailable plug halved – compared to above table Wooden planks / floorboards (screw-in depth 15 – 24 mm) Knauf Universalschraube FN multi-purpose screw halved – compared to above table 11 .40 5.00 312.00 312.00 7.de Maximum permissible fastener spacings Supporting fastening of perimeter runner (UW) connection on basic floor and subceiling Partition height Knauf Deckennagel ceiling Knauf Drehstiftdübel Knauf Universalschraube FN multi-purpose screw steel dowels nailable plug (with wooden substrates screw-in depth > 24 mm.00 7. 500 mm.5 4.55 5.00 312. 3 anchoring points).00 4. for fire protection constructions with partition height > 5.6 mm CW 50 CW 75 CW 100 CW 125 CW 150 Stud spacing Knauf boards 2x 12.00 to ≤ 6.50 5.00 m at spacing of max.00 1000 1000 1000 500 > 3.00 7. 5 + 12. length-related flow resistance acc.de Knauf Metal Stud Partitions Fire protection. to page 2 50 75 100 40 60 80 62 / 641) 64 / 651) 65 / 661) 69 . non-combustible) ■■ Sound insulation requirement: Mineral wool insulation layer acc.5 + 12. sound installation. technical data Technical and physical building data (Observe the notes/specifications on page 7) W113.5 81 2x 12.5 65 59 3x 12.5 + 12.5 101 125 150 175 1) Upper board layer stapled ■■ Always use Diamant as a covering layer with combined cladding Requirements for the insulation layer: (Insulation materials e.5 58 56 3x 12.de Knauf Metal Stud Partitions F30 Silentboard ■ ■ F90 ■ ■ ■ Stud spacing ■ a ■ F90 ■ ■ F30 Wall Profile thickness Minimum thickness t mm approx.5 101 69 3x 12.g.5 81 2x 12.5 58 56 3x 12.5 101 69 3x 12.W113. kg/m² D mm ■ ■ F90 ■ ■ ■ Knauf CW Insulation layer Cavity Minimum thickness h mm mm Sound reduction index Rw.5 58 61 3x 12. to EN 13162.R dB 3x 12.5 65 62 3x 12.5 65 59 3x 12.5 81 2x 12. triple-layer cladding ■ F30 Weight Without insulation layer Diamant Knauf Bauplate wallboard Fire resistance class t h D t Scheme drawings Massivbauplatte solid board Cladding per wall side Feuerschutzplatte Knauf Piano Knauf system Extension to the fire protection certificate of usability ■■ When applied with insulation layer G Prior consultation is recommended acc. from Knauf Insulation) ■■ Fire protection requirement: None ■■ Fire protection permissible: Mineral wool G (mineral wool insulation layer to EN 13162. to EN 29053: r ≥ 5 kPa • s/m² 12 Sound insulation Single metal stud frame. max. for fire protection constructions with partition height > 5.00 Without fire protection a mm ■■ With stapled upper board layer: Partition heights acc.00 12.00 5.00 5.40 9.00 312.5 6.00 9.00 11.00 9.de Maximum permissible fastener spacings Supporting fastening of perimeter runner (UW) connection on basic floor and subceiling Partition height Knauf Deckennaagel ceiling Knauf Drehstiftdübel Knauf Universalschraube FN multi-purpose screw steel dowels nailable plug (with wooden substrates screw-in depth > 24 mm.00 5.6 mm CW 50 CW 75 CW 100 CW 125 CW 150 Stud spacing Knauf boards 3x 12.00 9. to system W112.40 5.00 8.00 9.00 1000 1000 1000 500 > 3.00 8.00 417 10.00 6.75 10.85 9.00 312.15 312.5 mm m With fire protection F30 m F90 m Diamant 3x 12.00 625 9.50 to ≤ 12.00 417 12.65 417 6.00 9.20 5.85 5.05 8.00 500 – Verify the stability of the anchoring substrate and select suitable fasteners (for 2 kN/m) ≤ 3.W113.00 9.50 1000 500 500 250 > 6.00 to ≤ 6.35 5.50 to ≤ 9.00 to ≤ 6.50 8. 3 anchoring points).00 9.65 7.50 5.00 417 8.00 312.45 625 7.00 12.00 9.50 5.00 5.00 9.00 12.5 8.00 12.05 5.00 9.65 9.00 12.5 10.50 500 500 500 250 – Verify the stability of the anchoring substrate and select suitable fasteners (for 2 kN/m) With fire protection > 6.00 5.00 625 12.00 9.45 8.00 417 11.00 1000 1000 1000 500 > 3.00 to ≤ 5.00 11.00 12.65 5.00 312.35 10.00 1000 500 500 250 > 5.50 9.5 mm (all board layers screw fastened to stud frame) Without With fire protection fire protection F90 m m 625 5.5 12.00 12.05 5. Installation zones 1 and 2 Knauf profile Metal gauge 0. 500 mm.00 7.00 6.00 500 ■■ Constructional anchoring of the wall connection profiles (CW) to the flanking walls at centres of 1000 mm (min.60 5.85 9.00 9.00 m at spacing of max.00 625 11.00 9.5 11.00 9. Reduced maximum permissible spacings with edge fixing on floor constructions Supporting fastening of perimeter runner (UW) on floor constructions Anchoring substrate Fasteners Spacing of fasteners Pre-fab floor screeds Knauf Befestigungsschraube LG anchor halved – (multi-purpose screw) compared to above table Flowing screed Knauf Drehstiftdübel nailable plug halved – compared to above table Wooden planks / floorboards (screw-in depth 15 – 24 mm) Knauf Universalschraube FN multi-purpose screw halved – compared to above table 13 . fastener spacings Maximum permissible partition heights.00 9. subceiling) (with reinforced concrete) 1x 1x 2x 1x m mm mm mm mm Without fire protection ≤ 3.20 9.20 7.15 8.de Knauf Metal Stud Partitions Partition heights.75 5.00 9. from Knauf Insulation) ■■ Fire protection requirement: None ■■ Fire protection permissible: Mineral wool G (mineral wool insulation layer to EN 13162.5 52 ■ 2x 12.5 58 Stud spacing 155 205 255 ■■ Always use Diamant as a covering layer with combined cladding Requirements for the insulation layer: (Insulation materials e.5 + 12. length-related flow resistance acc. to EN 29053: r ≥ 5 kPa • s/m² 14 Knauf CW 2x 12.5 + 12. non-combustible) ■■ Sound insulation requirement: Mineral wool insulation layer acc.R dB 47 64 ■ ■ 12.5 58 69 ■ 2x 12. kg/m² D mm Insulation layer Cavity Minimum thickness h mm mm Sound reduction index Rw.W115.5 ■ F90 Minimum thickness t mm Sound insulation ■ ■ F90 Wall Profile thickness Double metal stud frame.g. double-layer cladding F90 a Weight Without Insulation layer Diamant Knauf Bauplate wallboard Fire resistance class t h D t Scheme drawings Massivbauplatte solid board Cladding per wall side Feuerschutzplatte Knauf Piano Knauf system Extension to the fire protection certificate of usability ■■ When applying the insulation layer G in conjunction with a partition height > 5. to EN 13162.00 m Prior consultation is recommended acc.5 47 67 ■ ■ 12.de Knauf Metal Stud Partitions Silentboard approx.5 52 65 ■ 2x 12.de Knauf Metal Stud Partitions Fire protection. sound installation.5 47 69 ■ ■ 12. to page 2 2x 50 105 2x 75 155 2x 100 205 2x 40 66 2x 60 2x 80 68 70 71 .5 + 12.5 + 12. technical data Technical and physical building data (Observe the notes/specifications on page 7) W115.5 58 12.5 67 71 ■ 2x 12.5 52 ■ 2x 12. 60 3.30 3.6 mm a mm Knauf boards 2x 12.00 1000 1000 1000 500 > 3. 500 mm.50 6.50 4.00 to ≤ 6.00 6.50 1000 500 500 250 ≤ 3.30 CW 75 625 4.50 5.60 3.50 5.80 2. 3 anchoring points).00 5.5 mm Diamant 2x 12.50 6.00 m at spacing of max.5 mm Installation zone 1 Without fire With protection fire protection F90 m m Installation zone 2 Without fire With protection fire protection F90 m m Installation zone 1 Without fire With protection fire protection F90 m m Installation zone 2 Without fire With protection fire protection F90 m m Knauf recommendation CW 50 625 3.00 5.00 6.80 3.00 5.00 1000 500 500 250 > 5.00 to ≤ 5. Reduced maximum permissible spacings with edge fixing on floor constructions Supporting fastening per perimeter runner (UW) on floor constructions Anchoring substrate Fastener Fastener spacing Pre-fab floor screeds Knauf Befestigungsschraube LG anchor halved – (multi-purpose screw) compared to above table Flowing screed Knauf Drehstiftdübel nailable plug halved – compared to above table Wooden planks / floorboards (screw-in depth 15 – 24 mm) Knauf Universalschraube FN multi-purpose screw halved – compared to above table 15 .50 CW 100 625 6.50 According to DIN 18183-1 CW 50 625 4.50 4. max.00 CW 75 625 6. fastener spacings Maximum permissible partition heights Knauf profiles Stud spacing Metal gauge 0.50 4. subceiling) (with reinforced concrete) 1x 1x 2x 1x m mm mm mm mm Without fire protection ≤ 3.00 Maximum permissible fastener spacings Supporting fastening per perimeter runner (UW) connection on basic floor and subceiling Partition height Knauf Deckennagel ceiling Knauf Drehstiftdübel Knauf Universalschraube FN multi-purpose screw steel dowels nailable plug (with wooden substrates screw-in depth > 24 mm. for fire protection constructions with partition height > 5.00 4.50 500 500 500 250 With fire protection ■■ Constructional anchoring of the wall connection profiles (CW) to the flanking walls at centres of 1000 mm (min.50 5.00 to ≤ 6.50 5.50 CW 100 625 5.00 6.30 3.00 4.de Knauf Metal Stud Partitions Partition heights.W115.00 4.00 1000 1000 1000 500 > 3.00 5.50 4.00 5.30 2.00 6.50 4. kg/m² D mm Sound insulation Knauf CW Insulation layer Cavity Minimum thickness h mm Sound reduction index Rw.W116.R mm dB 40 50 2x 40 54 40 52 40 52 Double metal stud frame. to EN 13162.5 43 2x 50 ≥ 105 Stud spacing 2x 12.00 m (F90) ▪▪ Cladding with Knauf Bauplatten wallboards Prior consultation is recommended acc.de Knauf Installation Wall Fire protection. Requirements for the insulation layer: (Insulation materials e. non-combustible) ■■ Sound insulation requirement: Mineral wool insulation layer acc.5 ■ a 48 ≥ 155 F90 ■ 2x 12. sound installation. length-related flow resistance acc. from Knauf Insulation) ■■ Fire protection requirement: None ■■ Fire protection permissible: Mineral wool G (mineral wool insulation layer to EN 13162.5 59 2x 40 61 ■■ Use impregnated boards in areas with moderate levels of humidity (recommendation acc. single/double-layer cladding ■ Stud spacing Weight Without Insulation layer Diamant Knauf Bauplate wallboard Fire resistance class t h D t Scheme drawings Massivbauplatte solid board Cladding per wall side Feuerschutzplatte Knauf Piano Knauf system 18 45 – ≥ 141 ■ F30 ■ 18 45 2x 12.g.de Knauf Installation Wall a Wall Profile thickness Silentboard Minimum thickness t mm approx. to EN 29053: r ≥ 5 kPa • s/m² 16 Extension to the fire protection certificate of usability ■■ When applying the insulation layer G in conjunction with ▪▪ Partition height > 5.5 59 40 60 ■ 2x 12. to page 2 . to DIN 18181). technical data Technical and physical building data (Observe the notes/specifications on page 7) W116. 00 Maximum permissible fastener spacings Supporting fastening per perimeter runner (UW) connection on basic floor and subceiling Partition height Knauf Deckennagel ceiling Knauf Drehstiftdübel Knauf Universalschraube FN multi-purpose screw steel dowels nailable plug (with wooden substrates screw-in depth > 24 mm. subceiling) (with reinforced concrete) 1x 1x 2x 1x m mm mm mm mm Without fire protection ≤ 6.00 5.50 6.50 500 500 500 500 With fire protection ■■ Constructional anchoring of the wall connection profiles (CW) to the flanking walls at centres of 1000 mm (min.50 6.50 4.50 5.00 5.50 1000 1000 1000 500 ≤ 5. for fire protection constructions with partition height > 5. 3 anchoring points).00 6.00 to ≤ 6. 500 mm.50 CW 100 625 4.00 5.50 6.00 3.00 3.00 3.50 4.00 6.de Knauf Installation Wall Partition heights. Reduced maximum permissible spacings with edge fixing on floor constructions Supporting fastening per perimeter runner (UW) on floor constructions Anchoring substrate Fastener Fastener spacing Pre-fab floor screeds Knauf Befestigungsschraube LG anchor halved – (multi-purpose screw) compared to above table Flowing screed Knauf Drehstiftdübel nailable plug halved – compared to above table Wooden planks / floorboards (screw-in depth 15 – 24 mm) Knauf Universalschraube FN multi-purpose screw halved – compared to above table 17 .00 4.00 1000 1000 1000 500 > 5.6 mm a mm CW 50 625 4.00 6.00 CW 75 625 4.00 4.50 4.5 mm Installation zone 1 m m Without fire protection Installation zone 2 With fire protection Without fire With protection fire protection m F30 m F90 m m F30 m F90 m Metal gauge 0. max.00 5.00 m at spacing of max.50 4. fastener spacings Maximum permissible partition heights Knauf profiles Stud spacing Knauf recommendation Diamant 18 mm Installation Installation zone 1 zone 2 Without Without fire fire protection protection According to DIN 18183-1 Knauf boards 2x 12.W116.50 5. 5 t2 30 t2 15 t2 20 1) Alternative possible: 1x 12.5 GKB ≥ 12.de Knauf Metal Stud Partitions Fire protection – upgrading existing walls Fire protection: Upgrading metal stud partitions with Fireboard Examples of horizontal sections single sided double sided Fireboard t1 t2 t2 Fireboard Fireboard Stud spacing ≤ 625 mm Stud spacing ≤ 625 mm ■■ Attachment of additional Fireboard cladding by screwing it onto the stud (alternative fastening method on request).5 + 12.5 + 12.5 + 12. to page 2 t1 t2 t1 t2 t1 t2 15 + 15 12.5 mm cementitious boards or 1x 10 mm calcium silicate board ■■ The existing wall must satisfy the requirements of the DIN 4103-1 18 Extension to the fire protection certificate of usability ■■ Upgrading existing walls Prior consultation is recommended acc.W11.5 GKF1) t2 without or with mineral wool in the cavity 15 t2 – – – t2 20 t1 t2 12.5 + 12.5 12. Existing partition Cladding per wall side Insulation layer Upgrade (required cladding.5 .5 GKB ≥ 2x 12.5 mm gypsum fibre boards or 1x 12.5 – 15 t1 t2 12. minimum thickness in mm) to F30 to F60 to F90 Fireboard single sided Fireboard single sided Fireboard single sided Fireboard double sided Fireboard double sided mm ≥ 12. 5 65 dB 12.de/ W625.5 GKB Insulation layer Upgrade (required cladding. from Knauf Insulation ►► Application of furring in accordance with System Data Sheet W61.de 30 mm AkustikDämmplatte TP 120 A Silentboard W625.de + W623.de CW stud Silentboard 40 mm TrennwandDämmrolle TI 140 T ■■ Fastening of the Silentboard (horizontal) by screw attachment to the studs ■■ Insulation materials e.R mm CW 75 Rw.de Knauf Trockenputz und Vorsatzschalen (Drylining and Furring) . minimum thickness in mm) Improvement of sound reduction index Sound reduction of entire construction after upgrading with boards after upgrading with furring ArrangeSilentboard Improvement Arrangement of Silentboard Sound ment of the furring reduction the boards index ΔRw.de 2x 12.5 + 5 dB W623.German only Existing partition Cladding per wall side Profile mm 2x 12.5 + 12.de 2x 12.de 12.W11.R 12.5 + 9 dB W626.5 62 dB 2x 12.5 + 7 dB W625.de 12.5 + 12.de Knauf Metal Stud Partitions Sound insulation – upgrading existing walls Sound insulation: Upgrading metal stud partitions with Silentboard Examples of horizontal sections With boards as additional cladding Silentboard With furring W623. further improvement in the sound insulation is possible.5 60 By fixing boards with Gypsum Board Screws.5 70 dB W626.de CD 60/27 with damping universal bracket W626.g. Values on request 76 dB 19 . ■■ See page 30 with demands made on the fire resistance.5 mm Silentboard on both sides ■■ 20 mm mineral wool TP 120 A ■■ Connection “Post” 2x L-angle 13/30/08 ■■ Connection “Wall” 2x L-angle 13/30/08 ■■ Wall break thickness 47 mm 48 49 49 49 56 55 53 58 55 53 58 56 53 5 ■■ 10 mm Diamant (cover layer) + 12.5 mm Silentboard on both sides ■■ 30 mm mineral wool TP 120 A ■■ Connection “Post” UD profile 28/27 ■■ Connection “Wall” UD profile 28/27 ■■ Wall break thickness 73 mm 50 49 49 49 57 56 54 59 57 55 60 58 55 6 ■■ 1x 12. 20 Total wall area .de Knauf Metal Stud Partitions Sound insulation. refer to the folder Sound insulation and room acoustics with Knauf (German only). ■■ The specifications for wall breaks with a width of 312.5 mm Silentboard (cover layer) + 2 mm galvanized sheet metal on both sides ■■ 20 mm mineral wool TP 120 A ■■ Connection “Post” 2x L-angle 13/30/08 ■■ Connection “Wall” 2x L-angle 13/30/08 ■■ Wall break thickness 47 mm 54 50 50 50 59 58 57 62 60 59 63 61 59 Insulation materials from Knauf Insulation Example: Drywall partition with 60 dB Wall break with 50 dB (alternative 5) with an area share of 8 % of the total partitioning component ■ Resulting sound reduction index is 57 dB ■■ Sound insulation proof: L 038-07. ■■ Interpolation between the area shares is permissible.R in dB Area share of the wall break 8 % 14 % 25 % 8 % 14 % 25 % 8 % 14 % 25 % 8 % 14 % 25 % 1 ■■ 1x 15 mm Diamant on both sides ■■ 20 mm mineral wool TP 120 A ■■ Connection “Post” 2x L-angle 13/30/08 ■■ Connection “Wall” 2x L-angle 13/30/08 ■■ Wall break thickness 50 mm 43 48 47 46 53 50 48 53 50 48 54 51 48 2 ■■ 1x 12.14 ■■ The specifications in the table apply for wall breaks with a width of 625 mm and the specified area share. wall breaks (examples) Alternatives Wall breaks with a length of 625 mm Wall break Design Sound reduction index Rw.5 mm or the calculation with divergent area shares.5 mm Silentboard on both sides ■■ 12 mm mineral wool TPE 12-2 ■■ Connection “Post” 2x L-angle 13/30/08 ■■ Connection “Wall” 2x L-angle 13/30/08 ■■ Wall break thickness 38 mm 44 49 48 47 53 51 49 54 52 49 54 52 49 3 ■■ 1x 15 mm Fireboard (cover layer) + 2 mm galvanized sheet metal on both sides ■■ 12 mm mineral wool TPE 12-2 ■■ Connection “Post” U profile 18/30/08 ■■ Connection “Wall” 2x L-angle 13/30/08 ■■ Wall break thickness 48 mm 48 49 49 49 56 55 53 58 55 53 58 56 53 4 ■■ 1x 12.R dB See page 21 for corresponding drawings Partition types Sound reduction index Drywall partition Drywall partition with 50 dB with 60 dB Drywall partition with 65 dB Drywall partition with 70 dB Resulting sound reduction index Rw.W11. de Knauf Metal Stud Partitions Sound insulation.W11. see page 20 for design 2 Metal stud partitions with joint section 3 Suitable fasteners: Spacing ≤ 500 mm 4 Suitable sealing. e. wall breaks (examples) Details. dimensions in mm Alternative 1 Alternative 2 Connection to façade Connection to stud partition Connection to façade Connection to stud partition 2 2 3 1 4 1 50 38 4 3 5 5 4 4 3 3 ≤ 625 ≤ 625 Alternative 3 Alternative 4 Connection to façade Connection to façade Connection to stud partition Connection to stud partition 2 2 3 3 4 1 1 48 47 4 5 5 4 4 3 3 ≤ 625 ≤ 625 Alternative 5 Alternative 6 Connection to façade Connection to façade Connection to stud partition Connection to stud partition 2 2 3 3 1 1 47 4 73 4 6 5 4 4 3 3 ≤ 625 ≤ 625 ■■ Partition height ≤ 4 m (larger partition heights on request) ■■ No vertical board joints are permissible ■■ Maximum spacings of the fasteners for perimeter runners (U / UD / angles) on the connection to the floor and ceiling: ≤ 500 mm Legend 1 Wall breaks. Trennwandkitt acoustical sealant 5 Schnellbauschraube TB drywall screw 6 Schnellbauschraube TN drywall screw 21 .g. scale 1:5 Horizontal sections. de KnaufKnauf Metallständerwände Brandschutz . use the ceiling connection without screw fastening with the UW runner.IV Without fire protection 1 2 3a Partition fire resistance class less than ceiling 1 2 3b Partition fire resistance class equal to ceiling 1 2 3c Suspended ceilings with a sole fire resistance class Fire exposure from below On suspended ceilings with protection from below. 1 2 No screw fastening with UW runner No screw fastening with the UW runner Deflection head on suspended ceiling Suspended ceilings in conjunction with basic ceilings of types I . use a deflection head in the standard design with movement play of at least 15 mm.W11.IV The stated fire rating only applies for the entire ceiling system (a) with suspended ceilings in conjunction with basic ceilings of types I .Anschlüsse an Decken to ceilings Fire protection. ■ Horizontal reinforcement of the suspended ceiling (max.de Metal Stud Partitions W11. 15 m x 15 m ceiling field size) or transfer of the load into the flanking components is necessary. but with the cladding connected to the suspended ceiling. the suspended ceiling alone must feature at least the same fire protection classification. if you can ensure in the event of a fire when the partition is destroyed prematurely. No screw fastening with UW runner Partition without fire protection 22 No screw fastening with UW runner Partition with fire protection Extension to the fire protection certificate of usability ■ Connections to fire rated suspended ceilings Prior consultation is recommended acc. to page 2 Copyright by Knauf Gips KG 3c Partitions with the same fire protection rating as the entire ceiling system (a) must be attached to the basic ceiling. connections Connection of "lightweight" partitions to fire protection classified ceilings Scheme drawings ■ Partitions may only be connected to fire protection classified ceiling systems (suspended ceilings). . perimeter runners (UW) must be integrated into the wall cladding thickness with gypsum boards.IV 3b If you fasten partitions with fire protection ratings to the suspended ceiling. that the remains of the partitions may fall without causing additional loading to the ceiling. the rating of the suspended ceiling must be at least that of the partition. ■The following connection configurations are possible (Further connections or detail designs can be found on page 35 or on request). ■ In the case that a partition with fire protection classification is connected to a suspended ceiling. With basic ceiling type IV: board strips a a a 3a Use ceiling connection of partitions without fire protection without screw fastening to the UW runner. Fire exposure from above (plenum) On suspended ceilings with protection from below and above / from above. Knauf ceiling systems Suspended ceilings with a fire rating solely for fire exposure fire exposure from below from above (plenum) Knauf partition systems Suspended ceilings in conjunction with basic ceilings of type I . Type and thickness of cladding complies to a “solely” suspended ceiling with the same rating as the partition Partition with fire protection With connection components of combustible building materials. 500 mm above the highest power socket. ■ The mineral wool area weight must be at least as follows: F30: ≥ 1. etc. ■ The entry of single electrical cables is permissible. ■ The mineral wool must fully cover the following area: Up to min. except not directly opposite one another. KG (available at: www. With board strips (only for single metal stud partitions) t ■ Enclose power socket with gypsum boards (≥ thickness t of the weakened cladding layer). to EN 13162. melting point ≥ 1000 °C acc. to DIN 4102-17 (e. they may be compressed to a thickness of ≥ 30 mm. down to the floor and laterally to the next studs on each side.g.kaiser-elektro. may be installed at any position with Knauf partitions. ■ Mineral wool insulation layer acc. sound insulation. 40 mm x 30 kg/m³) F60: ≥ 1. fire protection with Knauf (German only) Solutions for power sockets located opposite one another: see e. 500 mm above the highest power socket. dimensions in mm ■ Power sockets.g.6 kg/m² (e.2 kg/m² (e. see BS1 Brandschutz-Ordner. Schallschutz .de) Copyright by Knauf Gips KG 23 . ■ Insulation layers required for fire protection reasons shall be retained. With mineral wool (only for single metal stud partitions) Knauf board strips in cladding thickness ≥ 500 ≥ 500 Power socket (cavity wall socket) Compressed (≥ 30 mm) Mineral wool Power socket Board strips ■ Application of board strips with the same thickness as the cladding (glue to rear of board or fasten with gypsum board screws). switch sockets. splitter sockets.Einbauinstallation von Elektrodosen Fire protection.de Brandschutz.g. 60 mm x 40 kg/m³) ■ Compression of the mineral wool insulation layer up to a thickness of ≥ 30 mm is permissible.g.de Knauf Knauf Metallständerwände Metal Stud Partitions W11. insulation from Knauf insulation) Notes for avoidance of performance losses in noise reduction measures: ■ Avoid rigid connections with the opposite partition cladding ■ On partitions with sound insulation up to Rw 60 dB: ▪ Do not install power sockets opposite one another for each panel section ▪ Seal any remaining openings after installation of the sockets ■ Solutions for partitions with sound insulation exceeding Rw 60 dB or for sockets positioned opposite one another on request For access panel installation see Product Data Sheets for Knauf alutop Access Panels Solutions for cable and pipe penetrations. 40 mm x 40 kg/m³) F90: ≥ 2.W11. however. ■ The board strips must fully cover the following area: Up to min. The remaining openings must be sealed with gypsum mortar. KAISER GmbH & Co.4 kg/m² (e. With gypsum mortar With encasing using boards ≥ 40 Cladding Cladding Knauf gypsum board screw Power socket (cavity wall socket) Gypsum mortar Encased in cladding thickness ≥ 30 Power socket (cavity wall socket) Bond encasement with gypsum mortar to suit socket depth ≥t ■ Enclose power sockets in gypsum mortar (gypsum bed ≥ 30 mm thick). down to the floor and laterally to the next studs on each side. S Building material class A. of power sockets Installation of power sockets in Knauf metal stud partitions with fire protection ratings Scheme drawings.g. Cladding S ≥ 500 Power socket (cavity wall socket) ≥ 500 Knauf gypsum board screw or bond using gypsum mortar ≥ 500 ≥ 500 Cladding Power socket Mineral wool ■ Fill mineral wool cavity with mineral wool S secured against sliding. de-VM1 Board joint Board joint With fire protection: Use profile backing for front edge joints.de-VU1 Connection to basic floor without fire protection e. examples W111.W111.de-VO1 Connection to basic ceiling TRIAS + Trenn-Fix Diamant (vertical) Uniflott + Trenn-Fix Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs UW runner CW stud CW stud Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs W111. single-layer cladding Cladding installation Example: vertical cladding Board position Board width Knauf boards horizontal Silentboard 625 mm vertical Wallboard / Feuerschutzplatte Knauf Piano fire-resistant board / Diamant 1250 mm Stud spacing Details scale 1:5 W111. examples Connection to solid wall Vertical sections. should no insulation be installed Feuerschutzplatte Knauf Piano fire-resistant board (vertical) Schnellbauschraube TN drywall screw Uniflott Diamant (vertical) TRIAS Diamantschraube XTN screw UW runner CW stud Board joint Ceiling connection with shadow gap without fire protection Diamantschraube XTN screw Silentboard (horizontal) 24 Copyright by Knauf Gips KG Insulation layer as required W111.de-B1 W111.de Knauf Metal Stud Partitions Metallständerwand Einfachständerwerk .de-A1 Horizontal sections.g F127.de Feuerschutzplatte Knauf Piano fire-resistant board (vertical) CW stud UW runner Schnellbauschraube TB drywall screw Uniflott .einlagig beplankt Single metal stud frame. de-B1 W112.W112. examples Connection to solid wall Vertical sections. F231.de Knauf Metal Stud Partitions Metallständerwand Einfachständerwerk . examples W112.de CW stud UW runner Schnellbauschreube TN drywall screw Diamant (vertical) Steel staples (see page 5) Copyright by Knauf Gips KG Uniflott 25 .zweilagig beplankt Single metal stud frame.de-VM1 Board joint Board joint CW stud UW runner Diamant (vertical) TRIAS Diamantschraube XTN screw Insulation layer as required Uniflott Schnellbauschraube TN drywall screw Knauf boards W112.de-VO1 Connection to basic ceiling Uniflott + Trenn-Fix Knauf boards Uniflott + Trenn-Fix Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs UW runner CW stud CW stud Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs W112.g. double-layer cladding Cladding installation Example: vertical cladding Board position Board width Knauf boards horizontal Massivbauplatte solid board / Silentboard 625 mm vertical 1250 mm Wallboard / Feuerschutzplatte Knauf Piano fire-resistant board / Diamant Stud spacing Details scale 1:5 W112-A1 Horizontal sections.5 mm Diamantschraube XTN screw Knauf boards e.de-VU1 Connection to basic ceiling Board joint Top board layer stapled Cladding 25 mm + 12. g.de-VU1 Connection to basic floor Board joint Top board layer stapled Diamantschraube XTN screw Diamant (vertical) CW stud e. F127. triple-layer cladding Cladding installation Example: vertical cladding Board position Board width Knauf boards horizontal Silentboard vertical 625 mm Wallboard / Feuerschutzplatte Knauf Piano fire-resistant board / Diamant 1250 mm Stud spacing Details scale 1:5 W113. examples Connection to solid wall Vertical sections.W113.de-B1 Board joint W113.de Diamant (vertical) Steel staples (see page 5) 26 Copyright by Knauf Gips KG UW runner Diamantschraube XTN screw TRIAS .de-VO1 Connection to basic ceiling Uniflott + Trenn-Fix Knauf boards Uniflott + Trenn-Fix Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs UW runner CW stud CW stud Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs W113.de-VM1 Board joint Diamant (vertical) Diamantschraube XTN screw TRIAS Knauf boards Uniflott Schnellbauschraube TN drywall screw Insulation layer as required UW runner CW stud W113.de-A1 Horizontal sections. examples W113.dreilagig beplankt Single metal stud frame.de Knauf Metal Stud Partitions Metallständerwand Einfachständerwerk . de-VU1 Connection to basic floor Decoupling using self-adhesive insulation strips On entire wall height.W115. F126.de-A1 Horizontal sections.zweilagig beplanktcladding Double metal stud frame.) Diamant (vertical) Copyright by Knauf Gips KG CW stud e. spaced at ≤ 500 mm ≤ 500 ≤ 500 ≤ 500 Insulation layer as required Silentboard (horiz.de Knauf Metal Stud Partitions Metallständerwand Doppelständerwerk . dimensions in mm W115.g. examples Vertical sections. a ≤ 500 mm TRIAS Diamantschraube XTN screw Diamant (vertical) Schnellbauschraube TN screw Feuerschutzplatte Knauf Piano (vertical) Scheme drawing. a ≤ 500 mm UW runner Schnellbauschraube TN screw Uniflott 27 . examples W115. a ≤ 500 mm Self-adhesive insulation strip. double-layer Cladding installation Example: vertical cladding Board position Board width Knauf boards horizontal Silentboard 625 mm vertical 1250 mm Feuerschutzplatte Knauf Piano fire-resistant board / Diamant Stud spacing Details scale 1:5 W115.de-VO1 Connection to basic ceiling Connection to solid wall TRIAS + Trenn-Fix Trennwandkitt acoustical sealant Uniflott + Trenn-Fix Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs UW runner CW stud CW stud Knauf Drehstiftdübel nailable plugs W115.de Self-adhesive insulation strip.de-VM1 Board joint Board joint Self-adhesive insulation strip.de-B1 CW stud UW runner W115. see page 33 . UA profiles are required for fixing Refer also to System Data Sheet W21. horizontal cladding Board position Board width Knauf boards horizontal 625 mm Diamant GKFI 18 horizontal 1250 mm Wallboard / Feuerschutzplatte Knauf Piano fire-resistant board / Diamant GKFI 12. every 900 mm Knauf boards Knauf Flächendicht (moisture barrier) Knauf Flächendichtband e. every 900 mm. ≥ 300 mm high. approx.5 Stud spacing For installation. examples W116. approx.5 mm Knauf boards h > 300 mm to ≤ 500 mm: Thickness: ≥ 20 mm Knauf boards / ≥ 18 mm Diamant (with double-layer linking: individual board thickness ≥ 12. for example. ≥ 300 mm high. dimensions in mm Copyright by Knauf Gips KG W116.de Knauf Sanitär-Einbauteile sanitary built-ins (German only) Details scale 1:5 Knauf Flächendicht Knauf Flexkleber extra adhesive Tile without fire protection Knauf board strips. thickness dependent on wall cavity -hCW stud UW runner TRIAS Trennwandkitt acoustical sealant Drehstiftdübel nailable plugs UW runner Insulation layer as required CW stud Diamant GKFI 18 (horizontal) h Wall cavity Spacing Diamantschrauben screw XTN (2x 3 pcs) Vertical sections. at spacings approx.g. 900 Scheme drawing. 900 approx.einlagig / zweilagig beplankt Double metal stud frame. 600 approx.de-VM1 Board joint Diamant GKFI 12. to instalation requirement W116. F221. see page 29 28 ≥ 300 approx. every 900 mm Connection to solid wall. single/double-layer cladding Cladding installation Example: Diamant GKFI 18.de-VU1 Connection to basic floor Linking with Knauf board strips ≥ 300 mm high Thickness dependent on wall cavity -hh ≤ 300 mm: Thickness: ≥ 12. of a WC sanistand.de-B10 Horizontal sections.5 (horizontal) CW stud Diamantschraube XTN screw Diamantschraube XTN screw (2x 3 pcs) Diamant GKFI 18 (horizontal) Diamantschraube XTN screw Knauf boards Knauf board strips.W116.de Connection in high humidity areas.5 mm) On entire wall height.de-VO10 Connection to basic ceiling Board joint without fire protection acc. examples W116. 750 approx.de Knauf Installation Wall Installationswand Doppelständerwerk . de-D3 Corner – Flexible corner profiles without fire protection Flex profile Uniflott + Fugendeckstreifen Kurt joint tape Flex profile Flex profile Uniflott + Fugendeckstreifen Kurt joint tape Uniflott ≤a Corner trim Uniflott Corner trim ≤ a ≤a CW stud Flex profile a = stud spacing Installation aid: Connect flex profiles by crimping to the CW studs or UW runners Copyright by Knauf Gips KG 29 . Eckschutzschiene corner trim or Alux Kantenschutz edge trim Front board with mitering (glued) CW stud Trennwandkitt acoustical sealant Knauf Drehstiftdübel nailable plugs W115.de-A1 Horizontal sections.W11.de-END1 Detached end wall without fire protection Uniflott + Trenn-Fix Knauf boards without fire protection Schnellbauschraube TN drywall screw or Knauf Universalschraube FN multi-purpose screw CW stud Knauf boards Schnellbauschraube screw TN Knauf boards UW runner CW stud Front board If neccessary. a ≤ 250 mm Knauf boards W112.de-D1 CW stud CW stud If neccessary. freistehendes Wandende. Eckschutzschiene corner trim or Alux Kantenschutz edge trim Corner – CW studs + flexible corner profiles W112.de Knauf Metal Stud Partitions Metallständerwände Anschluss an Wandverjüngung. corners Details scale 1:5 W116. examples Connection to solid wall W116.de-D1 Corner UW runner CW stud Schnellbauschraube TN drywall screw or Knauf Universalschraube FN multi-purpose screw. Ecken Connection to Massivwand.de-D2 Stud spacing W112.de-D1 Wall breaks W112. detached wall ends. wall breaks. Eckschutzschiene corner trim or Alux Kantenschutz edge trim If neccessary. solid walls. a ≤ 250 mm Uniflott Corner Diamant CW stud TRIAS Schnellbauschraube TN drywall screw or Knauf Universalschraube FN multi-purpose screw. de Knauf Installation shaft walls / W61. Stud partition F30 Mineral wool S Extension to the fire protection certificate of usability Prior consultation is recommended acc. (e.de-A9 Connection to solid wall. to alternative 3 (F90) or alternative 6 (F30) on pages 20 and 21.g.5x11.g.de) CW stud 75 Knauf boards CW stud 50 Stud partition F90 Sound reduction index acc.de) CW stud Schnellbauschraube TN drywall screw or Knauf Universalschraube FN multi-purpose screw CW stud LDS glue bead Separation of the board layer with edge insulation strips 12 mm Extension to the fire protection certificate of usability Prior consultation is recommended acc. to DIN 4102-17.g.de type B) Knauf dry lining (e. to alternative 6 on page 20 ≥ Façade with 25 fire protection classification F30 Wall break design. W631. to page 2. fire protection F30 Wall breaks. Connection to façade/stud partition in accordance with the details above.de-A3 Connection to solid components. W112. W628.Metallständerwände W11.de-A8 Connection to dry lining without fire protection Knauf installation shaft wall (e. acc. melting point ≥ 1000 °C acc. examples. acc.de-A7 Connection to installation shaft wall W112. fire protection F90 Sound reduction index acc. to EN 13162: S non-combustible. to alternative 6 on pages 20 and 21 Mineral wool S Extension to the fire protection certificate of usability Prior consultation is recommended acc. to page 2. dimensions in mm W112. Mineral wool insulation layer acc. a ≤ 500 mm CW stud 75 a ≥ 20 ≥ a 20 a ≥ ≥ a 20 a 20 a a ≤ 20 mm a ≤ 20 mm Wall breaks.de Knauf Metal Stud Partitions Wandanschlüsse Connection to wall Details scale 1:5 Horizontal sections. to page 2.de Knauf Dry lining and furring Copyright by Knauf Gips KG . additional measures to cover the connection joint may be required (border profile. Connection to floor/ceiling and design of the wall break in acc. Knauf Insulation TPE 12-2) If necessary. to alternative 3 on pages 20 and 21 Knauf dry lining (W611. floating W112. corner trim or similar) Connection to façade without fire protection classification on request 30 See also System Data Sheets: W62. to alternative 3 on page 20 ≥ Façade with 25 fire protection classification F90 Wall break design. floating CW stud 50 Trennwandkitt acoustical sealant Metal screw LN 3. de-C6 T-junction. connection to CW stud CW stud Diamantschraube XTN screw or Knauf Universalschraube FN multi-purpose screw TRIAS CW stud (additional) Diamant W112.de-C5 T-junction.de-C3 T-junction with cavity dowel without fire protection UW runner Knauf boards UW runner Diamant Diamantschraube XTN screw Flex profile 200 or suitable inner corner trim TRIAS CW stud Trennwandkitt acoustical sealant Knauf Hohlraumdübel Hartmut cavity dowel.de-C1 T-junction. connection to Diamant Without fire protection Insulation layer as required CW stud Schnellbauschraube TN drywall screw or Knauf Universalschraube FN multi-purpose screw Uniflott Trennwandkitt acoustical sealant Knauf boards Befestigungsschraube LG 35 anchor.de-C2 T-junction with flex profile / Inside corner trim W112. a ≤ 1000 mm Uniflott Installation aid: Connect the Flex profile by crimping to the UW runners For further connection alternatives as well as specifications for flanking normalized level difference.de-C1 T-junction.de Knauf Metal Stud Partitions Metallständerwände TT-Verbindungen connections Details scale 1:5 Horizontal sections. connection to CW stud W112. examples W112. connection to CW stud Diamant Insulation layer as required UW runner Knauf boards CW stud Trennwandkitt acoustical sealant Knauf boards Schnellbauschraube TN drywall screw or Knauf Universalschraube FN multi-purpose screw Uniflott CW stud Trennwandkitt acoustical sealant CW stud (additional if necessary) W115.W11. spacing ≤ 250 mm CW stud Only Diamant is possible CW studs (additional) W112. see "Schallschutz und Raumakustik" with Knauf (German only) Copyright by Knauf Gips KG 31 . a ≤ 500 mm UD profile Blechschraube LN metal screw 3. e. glued and attached with Knauf gypsum board screws ≥ ≥ a 20 a 20 a ≥ ≥ a 20 a 20 a a ≤ 20 mm W112.W11.de-BFU4 Movement joint Insulation layer as required CW stud 50 Blechschraube LN metal screw 3.de-BFU1 Movement joint Knauf board CW stud 50 CW stud 75 a ≥ 20 a Edge trim is required Knauf board strips Schnellbauschraube TN drywall screw CW stud 75 Knauf boards UW runner 50 32 The rigid connection of the cladding layers leads to a local reduction of the sound insulation Knauf recommendation with wall cavity 50 mm Copyright by Knauf Gips KG a ≤ 20 mm W115.de-BFU2 Movement joint with joint profile W112.5x11.de-BFU1 Movement joint Insulation layer as required Knauf board strips ≥ 20 W112.de-BFU1 Movement joint Knauf board strips total thickness 50 mm. dimensions in mm W111.5x11. examples. a ≤ 500 mm CW stud 50 a ≤ 20 mm Insulation layer as required Knauf board strips Self-adhesive insulation strips ≥ ≥ a 20 a 20 a a ≤ 20 mm .de Knauf Metal Stud Partitions Metallständerwände Bewegungsfugen Movement joints Details scale 1:5 Horizontal sections. Migua CW stud Edge trim if required Knauf boards a ≥a a Dimensions to suit requirement and joint profile min.de-BFU2 Movement joint without fire protection without fire protection Schnellbauschrube TN drywall screw Knauf board Insulation layer as required CW stud Joint profile. 20 mm a ≤ 30 mm Stud spacing W111.g. Knauf flowing screed t2 Knauf boards t1+t2 ≥ 25 Knauf mineral wool edge insulation strips (melting point ≥ 1000 °C) t1 e.de Knauf Floor Systems .de Knauf Pre-fab screed / Brochure F20.W11.de-VU2 Floor connection to pre-fab floor screed W112.de Knauf Flächendicht / System Data Sheet D61.g.g. concrete floor Extension to the fire protection certificate of usability Prior consultation is recommended acc.g.de-VU2 Floor connection to self-levelling floor screed without fire protection CW stud Knauf boards CW stud Knauf board Knauf Befestigungsschraube LG anchor UW runner Trennwandkitt acoustic sealant Knauf pre-fab screed e. Brio 18 EPS (F127.de-VU3 Floor connection. Observe the reduced maximum permissible spacings (according to the tables of the respective systems) See also System Data Sheet F12.de Not to scale 1) Knauf Bauprodukte GmbH Drystar Board Knauf Flexkleber extra 1) Knauf Flächendicht sealant Edge sealing membrane.de-VU4 Floor connection to wood joist ceiling W112.g. dimensions in mm W111.g W116. to page 2. concrete slab Continuous screed layer reduces the sound insulation effectiveness W111.de Knauf Dachgeschoss-Systeme (German only) Copyright by Knauf Gips KG 33 . to System Data Sheet D61. Deckenanschluss Connections to floor.de) Uniflott Knauf Drehstiftdübel nailable plug Knauf flowing screed UW runner Trennwandkitt acoustical sealant Uniflott Insulation. non-combustible. Knauf Flächendichtband Foam backfiller Joint sealer. to page 2. reduced connection to basic floor Knauf Universalschraube FN multi-purpose screw Knauf board strips in cladding thickness CW stud Knauf board UW runner e.de Knauf Metal Stud Partitions Metallständerwände Bodenanschlüsse. e. examples. mineral wool e. Aluminium hygiene plinth Fugenfüller Leicht joint filler Knauf board strips in cladding thickness e. Knauf Sanitär Silicon 1) Knauf Flächendicht sealant Knauf flowing screed Connection to wood joist ceiling / attic storey system Not to scale Application in acc. Connection in high humidity area e.Construction and application technology / Product Data Sheet K435.g.g.de Extension to the fire protection certificate of usability Prior consultation is recommended acc. connection to ceiling Details scale 1:5 Vertical sections. de double-layer ≤ 20 ≥ 20 ≤ 20 ≥ 20 ≤ 20 ≥ 20 – – W112. 15.de Knauf Board Ceilings 34 Copyright by Knauf Gips KG fire protection b mm W116.de-VO3 Deflection head without fire protection ≥a ≥ 20 min.de triple-layer Observe the details in the table With a mm W111.de Knauf Metal Stud Partitions Metallständerwände Deckenanschlüsse Connections to ceiling Details scale 1:5 Vertical sections.de-VO2 Deflection head 1) Reduction of the sound insulation by approx. D112.W11.de double-layer ≤ 30 ≥ 10 ≤ 20 ≥ 20 ≤ 30 ≥ 10 ≤ 20 ≥ 20 W116. 3 dB Permanently elastic seal Knauf board strips (height is dependent on the deflection of ceiling) Observe the details in the table W115. 11.de single-layer Permanently elastic seal Knauf board strips (height is dependent on the deflection of ceiling) Without fire protection Max.50 ■ Observe permissible wall heights of the corresponding wall system (see pages 9.de-VO2 Deflection head 1) 1) Details for deflection heads Knauf system b mm ≤ 20 ≥ 20 ≤ 20 ≥ 20 W115.de-VO2 or upgrade suspended ceiling with a mineral wool insulation layer W116.de-VO2 Deflection head 1) Observe the details in the table a a Knauf filling compound Permanently elastic seal Knauf board strips (height is dependent on the deflection of ceiling) UW runner Suitable fixing material Knauf boards (do not screw onto the UW runner) CW stud ≥ 20 Edge trim if required a+5 b a+5 b a ≥ 20 a W112. permissible wall height m 6. 17) ■ Larger ceiling deflections / larger wall heights on request .de double-layer ≤ 30 ≥ 10 ≤ 20 ≥ 20 a a mm a ≥ 20 a+5 b See also System Data Sheet D11. 13. dimensions in mm W111.g. examples.de single-layer W113.de) Uniflott + Trenn-Fix For partition sound insulation requirement Rw > 45 dB: Make deflection head connection similar to as shown in W112.de-VO2 Deflection head with board ceilings W112. 20 mm ≥ 20 Knauf filling compound Screw fixing only in the area between studs Permanently elastic sealant Knauf board strips CW stud Knauf boards a ≥ 20 a without fire protection a ≤ 20 mm Knauf board ceiling (e. 0 mm with Ø 2.g. to page 2. slot strap.0 mm use approved anchors Horizontal bracing through diagonal bracing (e.g. Knauf Board Ceiling D112 CD channel Screw intersection connector to CD channel on each side Extension to the fire protection certificate of usability Prior consultation is recommended acc.de Knauf Metal Stud Partitions Metallständerwände Deckenanschlüsse Connections to ceiling Details scale 1:5 Vertical sections. Uniflott + Trenn-Fix Trennwandkitt acoustical sealant UW runner Knauf Universalschraube FN multi-purpose screw No screw connection with the UW runner Knauf boards UW runner CW stud Uniflott + Trenn-Fix Trennwandkitt acoustical sealant Suitable fasteners.de Knauf Fireboard beam and column encasements Copyright by Knauf Gips KG 35 . D113.g.de Permissible partition height: ≤ 4 m (higher on request) Extension to the fire protection certificate of usability Prior consultation is recommended acc.g.de Suspended ceilings with a sole fire rating.5 mm with Ø 3.de-VO6 Ceiling connection to board ceiling W112.0 mm Drill t ≥ 1.de Knauf board ceilings / K217. a ≤ 500 mm 1) Trapezoid metal gauge Drill t ≥ 1. a ≤ 500 mm No screw connection with the UW runner Knauf boards Horizontal bracing by load distribution via ceiling slab on the flanking walls (load-bearing connection to ceiling required) Also refer to System Data Sheets: D11. Knauf System K217. Diagonal bracing with slot strap in the suspender area Knauf board ceiling e.de Uniflott + Trenn-Fix Uniflott + Trenn-Fix Trennwandkitt acoustical sealant UW runner Knauf Universalschraube FN multi-purpose screw1) No screw connection with the UW runner Knauf boards UW runner Cavity dowel. fire exposure from below e.de-VO8 Connection to steel beam cladding Permissible partition height: ≤ 4 m (higher on request) Fire protection classified beam encasement must be at least one fire resistance classification higher than the partition (e. Apply in accordance with Knauf System Data Sheet K25. e. examples W112.g.W11. to page 2.de Knauf trapezoid sheet metal system with Fireboard / K25.de-VO5 Ceiling connection to trapezoid sheet metal ceiling without fire protection Fire protection classified trapezoid sheet metal constructions with continuous cladding e. CD channel) W112.de-VO4 Ceiling connection to board ceiling W112.0 mm t ≥ 2. F120 with partition F90).g. to DIN 18340: Partition height > 2.60 m Door width ≤ 0. e.885 m Door leaf weight > 25 kg Door frame bracket "top" Attach with enclosed dowels Door frame bracket "top" Attach with enclosed dowels Door lintel profile option: UW runner CW stud Door frame bracket "bottom" Attach with enclosed dowels Door frame bracket "bottom" Attach with enclosed dowels Door frame bracket "top" Fastening.de Knauf Statikstütze (German only) .W11. 860 . 985 . in schools.775 mm.g. with Knauf Drehstiftdübeln nailable plugs "L" 8/100 UA profile or CW stud Door lintel profile option: UW runner UA profile room height (not jointed) Remove plastic strips on Türpfostensteckwinkel door frame brackets Option: Knauf UA profile connection angles Door opening frame Deflection head Option CW or UA possible Cladding – partition side 1 For ceiling deflection up to max. door profile only possible with UA profiles and Knauf connection angle for UA 100 required at top and bottom ▪ Manufacture the lintel profile using UW runners 36 ■ Knauf Türpfostensteckwinkel door frame brackets for CW studs and UA profiles 50 / 75 / 100 Consisting of: 4 brackets + 10 dowels ■ Knauf Anschlusswinkel connection angle for UA profiles 50 / 75 or 100 / 125 / 150 Consisting of: 4 brackets + 8 dowels + 8 carriage bolts with nuts and washers ■ Knauf Türsturzprofil door lintel profile for CW studs UA profiles 50 / 75 / 100 Prepunched for door opening sizes: 610 . metal stud constructions Option CW Acc.900 mm.de Knauf Metal Stud Partitions Metallständerwände Türöffnungen Door openings Door opening profiles.1025 mm Copyright by Knauf Gips KG ■ Support to accept higher door leaf weights (up to 170 kg) and cantilever loads ■ Apply for partition openings with high door leaf weights.g. 40 mm shorter than partition profiles (note the construction conditions. to DIN 18340: Partition height ≤ 2. 20 mm Cladding – partition side 2 ≥ 150 mm ≥ 150 mm Do not apply board joints on door frame profiles Maximum door weights Knauf static support Door leaf width Option CW CW studs Option UA UA 50 UA 75 UA 100 UA 125 UA 150 ≤ 885 mm ≤ 25 kg ≤ 50 kg ≤ 75 kg ≤ 100 kg ≤ 125 kg ≤ 150 kg ≤ 1010 mm – ≤ 50 kg ≤ 75 kg ≤ 100 kg ≤ 125 kg ≤ 150 kg ≤ 1260 mm – ≤ 40 kg ≤ 60 kg ≤ 80 kg ≤ 100 kg ≤ 120 kg ≤ 1510 mm – ≤ 35 kg ≤ 50 kg ≤ 65 kg ≤ 80 kg ≤ 95 kg ■ Knauf recommendation: For double stud partitions apply door openings with UA profiles ■ Door stud profiles (CW / UA) approx.60 m Door width > 0.885 m Door leaf weight ≤ 25 kg Scheme drawings Option UA Acc. additional deflection head) ■ When partitions applied with profiles 125 or 150: ▪ For construction reasons. e. hospitals and administration buildings ■ For UW 75 or UW 100 profiles ■ Room heights: < 2900 mm / < 3800 mm (greater heights / special heights on request) ■ Screw fix the Knauf boards using standard screws TB/XTB Top Support profile Base Also refer to Product Data Sheet: K691a. e.g.650 mm. 735 . de-E1 Door opening with UA profile without fire protection without fire protection Schnellbauschraube TB drywall screw Knauf boards Opening width Schnellbauschraube TN drywall screw Knauf boards Opening width UW runner Türpfostensteckwinkel door frame bracket CW stud as a door opening profile UW runner Türpfostensteckwinkel door frame bracket UA profile as a door opening profile W116.g.de-E2 Door opening with CW stud W113. fire protection certification.de Knauf Schiebetür-System Pocket Kit (German only) Maximum openings in metal stud partitions Scheme drawings CW studs as reveal studs UA profiles as reveal studs UW runners or door lintel profile a a a a a UA profile a a a a Stud spacing Closed partition b ≤ 3a Opening No partition height limitation a a a a UA profile ≥ b Closed partition ≥ b Closed partition ■ Stud spacings ≤ 625 mm ■ Observe permissible wall heights of respective partition system ■ Larger opening widths / partition heights on request ■ The respective installation conditions must be observed with door installation Copyright by Knauf Gips KG a a Stud spacing CW stud ≥ b a b ≤ 5a Opening Up to 3a: No partition height limitation Up to 4a: Partition height ≤ 6. if required Continuous insulation strips along entire door height Continuous insulation strips UW runner Türpfostensteckwinkel door frame bracket UA profile as a door opening profile UW runner Türpfostensteckwinkel door frame bracket UA profile as a door opening profile Additionally.de-E1 Door opening with UA profiles without fire protection without fire protection Schnellbauschraube TB drywall screw Knauf boards Opening width Schnellbauschraube TB drywall screw Knauf boards Opening width For centre door frame connection.50 m Up to 5a: Partition height ≤ 4.de-E1 Door opening with UA profiles W115. Door openings.de Knauf Metal Stud Partitions Metallständerwände Türöffnungen. the specifications of the door manufacturer must be observed (e. integrate sheet metal.Wandöffnungen partition openings Details scale 1:5 Horizontal sections.W11. additional constructional measures.00 m ≥ b Closed partition 37 . examples W112.) Fire protection only in conjunction with a corresponding fire protection closure Also refer to brochure W496. etc. Knauf Drehstiftdübel nailable plugs Angle or profile as board support Knauf board strips . 2.5 mm e. Put the cut-to-length Knauf boards on a grid made of channels or similar with the side to be compressed on top (to ensure that excess water can drip off). example W111.5 GKB e t o b c ompr e e c d f a s ide si ≥ 300 s ed ≥ 1000 Convex – outer arch es 6. bend and fix the board with adhesive tape and allow to dry. Slowly bend the Knauf board laterally over the stud partitions. Pre-bending on a template is recommended. Wet the board by spraying or use a lambskin roller and allow it to settle for a few minutes. e. With impregnated boards: Observe the extended time required to take effect due to hydrophobic properties.g. 3.W11. 75 and 100 mm.g. 2.5 mm (external radius) ■ Knauf fastener spacings: ≤ 300 mm ■ Horizontal cladding Horizontal section. Batten to fix the bent board Template Detail scale 1:5 Installation instructions ■ Connect the CW studs to the Knauf Sinus with a crimp connection ■ CW stud spacing: ≤ 312. 4. Length to be applied in longitudinal direction ■ Bend only in the longitudinal direction Template Bent Knauf board Cut board d ≥ 12.5 Diamant ≥ 2750 ≥ 1000 d 12. ■ Wet bending 1.5 GKB / GKF r se ≥ 500 si ≥ 2000 t r to de 9. ▪ Possible radii: Strap Sinus External radius Flange 50 ≥ 125 mm Belt 75 ≥ 175 mm 100 ≥ 250 mm CW stud Fix Sinus belt to Sinus flange by crimping Sinus strap bent back Knauf Sinus Schnellbauschraube TN drywall screw Curved Knauf board Uniflott + Fugendeckstreifen Kurt joint tape 38 Copyright by Knauf Gips KG UW runner Fasteners. Fix with drywall screws continuously following the bending direction.de-SO1 Curved partition without fire protection Connect UW runner to Sinus belt by crimping Knauf Sinus: ▪ Available in widths 50. Repeat the process until saturation is achieved and allow the excessive water to drain. Place the board on the prepared template. length 1900 mm.de Knauf Metal Stud Partitions Metallständerwände Gebogene Wände with mit Knauf Curved partitions KnaufSinus Sinus Bending radii of Knauf boards ≥ 2750 ≥ 1000 12. Perforate the board laterally and longitudinally with a spiked roller.5 (Formplatte) Concave – inner arch es Bend radius r in longitudinal direction Dry bending Wet bending mm mm Board thickness t mm r be co m p f a ce t s i de ■ Other Knauf boards / bending radii on request ■ Fire protection designs on request Bending instructions for Knauf boards Scheme drawings ■ Dry bending 1. ▪ The desired curvature can be implemented at any location. The straps are simply bent by simple application of finger pressure and the profile is made flexible at this location. de / W112.5 metal screw 1) UW runner on partition connection Knauf boards Knauf Drehstiftdübel nailable plugs UA profile UW runner CW stud (stud profile) Detail "A" UW runner UA profile Blechschraube LB 3.de / W112.de Knauf board UW runner UA profile UW runner Partition height Wall width = Span width with UA profile Blechschraube LB 3.de Knauf Metal Stud Partitions Metallständerwände W111.5 mm m UA 50 3. to W111.50 5.00 6.de/W112.5 mm Metal gauge 2 mm m Cladding ≥ 2x 12.de to ceiling UA profile View Scheme drawing Max.00 4.50 Detail "A" ■ Larger partition widths / Installation zone 2 on request UW runner ■ Permissible partition height: ≤ 4 m (larger heights on request) ■ UA profiles must not be jointed ■ Fire protection and sound insulation requirements cannot be met with this partition construction ■ Door / wall openings on request Detail scale 1:5 CW stud Vertical section. permissible total load: UA 50: ≥ 1 kN UA 75 / UA 100: ≥ 2 kN UW runner on connection to wall Floor connection acc.5x9.dewithout .de / W112.ohne connection Deckenanschluss W111.de 1) Fixing spacings in accordance with the spacings in the tables on pages 9 and 11 for Knauf Universalschraube FN multi-purpose screws Copyright by Knauf Gips KG 39 .5 metal screw 1) UW runner Anschlusswinkel connection angle for UA profiles ▪ Connection to UA profile: 2x M8 hexagon head screws ▪ Anchoring to a solid wall: Suitable anchors. example Scheme drawings Detail "B" Knauf boards UW runner Schnellbauschraube TB drywall screw UW runner UA profile UW runner Partition height ≤ 4 m Detail "B" Partition width Metal stud partition without ceiling connection W111. permissible partition widths Installation zone 1 Cladding ≥ 12.5x9.W11.00 UA 75 4.50 UA 100 5. ■■ Determine the minimum number of dowels using the cabinet weight and loading of the selected dowel type in dependence on the cladding thickness (see calculation examples on page 41).de Knauf Statikstütze (German only) W234. Sanistands from Glock GmbH (available at www.4 kN/m or 0.glockgmbh. Knauf Befestigungsschrauben LG anchors Cladding thickness Max.de Knauf Multi-purpose Traverse ►► See System Data Sheet W21. screw length: Cladding thickness + thickness of object to be fixed Up to 65 kg – cavity dowel For anchoring cantilever loads up to 0. Molly Screw anchor or equivalent 2) Preferably in conjunction with systems W112.de. 40 Ca b ≤ 6 dep inet 00 th mm width Cabinet m m 0 0 2 1 ≤ . wall-hung WCs. picture frames ▪▪ Only shear loading up to 15 kg ■■ Knauf Befestigungsschraube LG anchor: ▪▪ Light items: e. cantilever loads Fixing loads Up to 15 kg. Cabinet height ≥ 300 mm Wall mounted cabinet: Excentricity ≤ 300 mm With stapled upper board layer: Only the screw fixed board layer may be used to transfer the load.g.7 kN/m Cladding Maximum dowel loading capacity Metal cavity thickness Plastic cavity dowel dowel Ø Screw 8 mm or 10 mm M5 or M6 1) Knauf Hohlraumdübel Hartmut cavity dowel Screw M5 Up to 1. sanistands.de Knauf Sanitär-Einbauteile (Knauf Sanitary Built-ins) kg 1) e. Knauf Hartmut Hohlraumdübel cavity dowels.5 40 45 50 55 55 60 ≥ 2x 15 45 50 55 60 60 65 Knauf Statikstütze ►► See Product Data Sheet K691a. handles ▪▪ Cantilever loads: e. ■■ Fixing spacing of the dowels according to DIN 18183: ≥ 75 mm.de W234. Fischer Universal.5 LG 25 8 10 12 15 LG 25 10 12 15 18 LG 35 – 14 18 2x 12.5 kN/m partition length (e. hook load capacity Up to 5 kg Up to 10 kg Fixing screws mm Up to 15 kg Max.g. Knauf Statikstütze) to transfer the load into the substructure Examples: 1) Diamant Knauf boards kg kg Diamant Knauf boards kg kg Diamant mm Knauf boards kg 12. ■■ Consideration of the cantilever arm (cabinet height ≥ 300 mm) and eccentricity (≤ 300 mm at cabinet depth ≤ 600 mm) is required.W11. W116.g.5 kN/m for traverses.g. (Knauf recommendation: ≥ 200 mm).g. wall cupboards) in accordance with the specifications on page 41. W113. ■■ Attach the cantilever loads with at least 2 cavity dowels made of plastic or metal. Tilt protection for standing shelves ▪▪ Tension or shear loading up to 24 kg ■■ Cavity dowels: ▪▪ Higher fixing loads: e.de) Type and usage of the fastners Cantilever loads (observe page 41) ■■ X-Hooks: ▪▪ Light items: e.g. screw loads Knauf GKB mm Knauf GKF mm Diamant mm 12. partitions can be loaded at any position by cantilever loads (e.4 kN/m or 0.7 kN/m up to 1.de 3) e. X-Hooks Up to 24 kg. e.5 LG 35 16 20 24 Min. Knauf Statikstütze Cantilever loads > 0.g. kitchen cupboards ▪▪ Combined tension or shear loading up to 65 kg ■■ According to DIN 18183.5 25 30 30 35 35 40 15 / 18 30 35 35 40 40 45 2x 12. boilers. washbasins) using traverses2) or sanistands3) or special profiles (e.g.g.g.de. TVs.de Knauf Metal Stud Partitions Fixing loads. Tox Universal. 5 33 28.5 51 46. cabinet width 800 mm ■■ With cabinet depth 450 mm 1 vertically upwards. permissible cabinet weight (kg) according to table Cabinet width Cabinet depth mm mm 100 200 300 400 500 600 400 31 28 25 22 19 16 600 46.5 70 1200 129 120 111 102 93 84 Max.5 24 800 62 56 50 44 38 32 1000 77. permissible cabinet weight Cabinet width kg or With intermediate values assume the worst-case value or use diagram procedure 100 90 80 70 60 50 40 30 20 10 3 2 mm 1200 1000 800 600 400 1 mm 100 200 Cabinet depth 300 400 500 600 Up to 0. to ABP P-1405/928/10) / ≥ 18 mm Knauf boards Max. cabinet width 1000 mm ■■ Cladding thickness 12. at this intersection point horizontally to the left .W11. Knauf Hartmut Required number of dowels: 65 kg : 55 kg = 1.5 70 62.4 kN/m are permissible.5 55 47.2 3 dowels are the minimum requirement 55 kg 25 kg (see table above) (see table on page 40) According to the diagram ■■ 0. permissible cabinet weight (kg) according to diagram Max. kg or 120 110 100 90 80 70 65 60 50 40 30 20 10 Cabinet width mm 1200 3 2 1000 800 600 400 1 mm 100 200 Cabinet depth 300 400 450 500 600 Calculation examples – Determination of the permissible cabinet weight as well as the necessary minimum number of dowels (always ≥ 2) According to table ■■ 0. permissible cabinet weight (kg) according to diagram Max.5 mm.7 kN/m ■■ Cabinet depth 450 mm.5 40 1200 93 84 75 66 57 48 Max. to DIN 18183-1.de: When using partition heights acc.7 kN/m (70 kg/m) wall length: Cladding thickness ≥ 15 mm Diamant(in acc. up to line cabinet width 800 mm 2 .de Knauf Metal Stud Partitions Cantilever loads acc.4 kN/m (40 kg/m) wall length: Cladding thickness < 15 mm Diamant / < 18 mm Knauf boards Max.5 100 92.read off 3 : ■■ Cladding thickness 2x 12.5 42 800 86 80 74 68 62 56 1000 107.18 Maximum cabinet weight: 65 kg (see diagram above) Maximum dowel load: 55 kg (see table on page 40) 2 dowels are the minimum requirement 41 .5 60 55.5 42 37.4 kN/m ■■ Cabinet depth 400 mm.5 mm. to DIN 4103-1 and DIN 18183-1 Cantilever loads (observe page 40) Up to 0.5 85 77. cantilever loads only up to 0. permissible cabinet weight (kg) according to table Cabinet width Cabinet depth mm mm 100 200 300 400 500 600 400 43 40 37 34 31 28 600 64. permissible cabinet weight With intermediate values assume the worst-case value or use diagram procedure System W115. plastic cavity dowels Maximum cabinet weight: Maximum dowel load: Required number of dowels: 55 kg : 25 kg = 2. W11.0 4.5 mm Knauf UW runner. Drehstiftdübel nailable plug “K” 6/35 Insulation layer.8 as req.de Diamant Diamant Massivbau15 mm 2x 12.5 mm or 15 mm or 18 mm m2 2 4 2 – 4 2 W113.0 Knauf sealing tape pieces 70/3.1 1.8 1. as req. e.8 1. as req.de Knauf Metal Stud Partitions Material requirement for selected examples Material requirement per m2 partition (without allowance for loss and waste) 2.0 Fugendeckstreifen Kurt joint tape (for front edges) m as req. CW 50 m 2.g. Knauf fasteners see page 5) 1st layer pcs 30 14 20 14 14 36 2nd layer pcs – 30 30 18 30 – 3rd layer pcs – – – 30 – – Knauf filling compound. e. as req. e. = as required ■■ Details without specific requirements on the building physics Unit 4.g. Jointing (e.g. as req.g.2 m2 as req.6 3.5 – Knauf board strips.5 0.00 m2 ■■ as req.6 1. L = 4.g.2 mm. as req.3 0. as req.g.7 0. Diamant 18 mm m2 – – – – – 0. as req. Trenn-Fix.2 mm m 1. Kantenschutzprofil edge trim 23/13 m 1) Alternatively.5 mm platte solid board 25 mm + Diamant 12.75 m.7 0. e.2 1. 12. Knauf Knauf Insulation2) boards2) Fastening (Fastening of the boards.g.g. 25 mm m2 – – 2 – – – Diamant.3 0.0 2. as req. A = 11.8 1.8 1. as req.5 mm 18 mm Stud frame1) or Knauf fastener.00 m.8 1. Feuerschutzplatte Knauf Piano fire-resistant board.de Feuerschutzplatte Knauf Piano 3x 12.6 1.8 1.00 m Description Quantity as average value W111.2 2.2 1. e.2 1.1 Board strip fixing.3 0.2 3.0 2. as req.0 0. 50/3. as req.g. e.8 1.4 1. as req.6 Knauf Dichtungsband sealing tape. 12.de W116. as req.de W112.0 4.7 1.5 mm W115. Knauf Diamantschraube XTN screws pcs – – – – – 7 Knauf Trennwandkitt acoustical sealant pcs 0.75 m ■■ The quantity relates to a partition area of: H = 2.4 2.6 1.3 0. quality level Q2) .6 0. see also page 43 Knauf edge/corner trims. as req. Uniflott or TRIAS kg 0. e.g.7 0. self-adhesive m 1. 65 mm wide. (100 mm long) m – – – – 0. different profile sizes can be used (observe the specifications of the respective partition system) 2) Observe the fire protection / sound insulation requirements ■■ With Fireboard cladding: Always use Knauf Fireboard-Spachtel filler + Knauf Glasfaser-Fugendeckstreifen fibre glass joint tape (long and front edges) 42 .de Diamant Diamant 2x 12.4 pcs 1. e. as req. e.4 Knauf CW stud. UW 50 m 0.0 2.5 mm m2 – – – 6 – – Massivbauplatte solid board. Gypsum board joints ■■ For multi-layer cladding.g. water glass paints and silicate-based paints. ■■ Do not apply jointing at room or substrate temperatures below approx. Finishing filler to achieve the desired surface quality: ■■ Q2. ■■ Observe code of practice no. cementitious screed and self-levelling screed.F. Filling the joints of covered cladding layers with multi-layer cladding is necessary to ensure technical fire protection and sound insulation properties as well as the structural properties! ■■ Recommendation: Front edge and cut edge joints as well as mixed joints (e.g. easy blending.und Klebearbeiten” released by the Bundesausschuss Farbe und Sachwertschutz (Germany). quick drying must be ensured through adequate airing. halfrounded tapered edge + cut edge) of the visible cladding layers filled using Uniflott or TRIAS. if required. Application temperature / climate ■■ Filling and covering of joints should only take place when no more longitudinal changes can be expected. ■■ With Fireboard. application by hand: Readygips ■■ Q3/Q4. however. 3 “Gipsplattenkonstruktionen .g. –bekleidung” 1). fleece.L. ▪▪ With narrower cladding thickness.g. dependent on the conditions and the demands on crack resistance with Trenn-Fix or Knauf Fugendeckstreifen Kurt joint tape. A sealing primer of Knauf Flächendicht is required for covering splash water areas with tiles. coatings and linings Jointing Surface quality ■■ Jointing of the boards in the required quality level Q1 to Q4 in accordance with Code of Practice no. it must be dust free and a full surface skim with Knauf Fireboard-Spachtel filler has to be applied. a trial coat is recommended that will extend across several boards including all joints.L.de Knauf Metal Stud Partitions Jointing. 6 of the BVG “Vorbehandlung von Trockenbauflächen aus Gipsplatten zur weitergehenden Oberflächenbeschichtung bzw. ■■ In case of mastic asphalt screed. Knauf Atonol for coatings. Diamant Spritzputz. will require the application of Fugendeckstreifen Knauf joint tape as well. acc. the surface must at least have quality level Q2. green colour for easy identification.. Notes After wallpapering or after application of plasters. Malerweiss E. with high strength and suitable for areas of high humidity. machine application: Readygips. very smooth application and easy to sand. reduce the stud spacing to max. Rotkalk Filz) ▪▪ Full surface plaster (e. Knauf Readygips. ■■ Fugenfüller Leicht: Hand filling with Knauf Fugendeckstreifen Kurt joint tape. ■■ Coatings ▪▪ Dispersion paints (e. or for Fireboard. Multi-Finish). Coatings and linings For direct application of a coating or wallpaper. Unsuitable are: ■■ Alkaline coats such as lime-based paints. Therefore. ■■ Apply Trenn-Fix when filling joints to adjacent solid construction components. ■■ Fireboard Spachtel filler: Hand filling of Fireboard with fibre glass joint tape. i. 1 “Baustellenbedingungen” 1). to code of practice no. 2 “Verspachtelung von Gipsplatten. textile and synthetic wallpapers: Use only adhesives made of methyl cellulose according to Code of Practice no. seal the connection to the floor with joint filler. expansion or contraction due to humidity or temperature changes. Yellowing can. Suitable coatings and linings The following coatings/linings can be applied to Knauf boards: ■■ Wallpapers ▪▪ Paper. Gypsum board surfaces that have constantly been exposed to light without any protection can result in yellowing. Knauf ProSpray Light ■■ Fireboard-Spachtel filler for full surface skimming of Fireboard. for sound insulation demands only acrylate or Trennwandkitt acoustical sealant may be used. ■■ Observe code of practice no. ■■ Ceramic tiles ▪▪ Minimum cladding thickness 18 mm (Diamant: 15 mm) with stud spacing 625 mm. ▪▪ Silicate-based emulsion paints with suitable primer. In order to compensate for the differences in absorption of surfaces.F. Where a wallpaper lining is used. ■■ Other coatings or layers and vapour barriers up to about 0.W11. 417 mm. coatings of primer such as Knauf Tiefengrund or Spezialgrund are suitable.V.Fugen und Anschlüsse” 1). ■■ With fire protection demands.) ▪▪ Multicoloured rainbow emulsion 1) Issued by the Industriegruppe Gipsplatten im Bundesverband der Gipsindustrie e. Knauf Noblo. Connection joints ■■ Apply connections to the flanking drywall construction (ceiling/wall). be successfully avoided only by using a special primer. fill the joints of the visible layer. fill in board joints only after screed has been applied. 16 “Technische Richtlinien für Tapezier. ■■ Fill in visible screw heads. +10 °C. ■■ Lightly sand visible surfaces after drying of the filler material. Pretreatment Before further coatings or linings (wallpaper) are applied. 43 . e. fill the lower layers with filler.5 mm thickness as well as claddings (with the exception of sheet steel). a primer that facilitates easier removal of wallpaper for redecoration is recommended. the ideal filler particularly for systems with Diamant boards. Oberflächengüten” 1). reduced absorption for surfaces with uniform appearance. ■■ Uniflott: Hand filling without joint tape strips in the long joint edges ■■ Uniflott imprägniert impregnated: Hand filling of impregnated (green) boards without without joint tape in the long joint edges. the filled surface must be free of dust and the surface of the gypsum boards should always be primed. water-repellent. Knauf SuperFinish ■■ Q3/Q4. Knauf Intol E. Application of plaster layers only in conjunction with Knauf Fugendeckstreifen Kurt joint tape. Filling compounds Suitable filling/jointing compounds: ■■ TRIAS: Hand filling without board tape in the long joint edges. ■■ Plasters ▪▪ Finishing plasters (e. The primer must suit the subsequent coating compound/coatings/linings. Knauf Aton Sperrgrund for finishing plasters.g. a skim coating of the entire surface with Knauf Fireboard-Spachtel filler is additionally required before application of direct coatings or linings. do not have any influence on the technical fire resistance classification of Knauf Metal Stud Partition systems. application by hand: Readygips.e. appropriate standards. be coordinated Wir empfehlen. DGNB/BNB Ecological quality ■■ Criterion: Risks for the local environment → The relevant environmental data are contained in the EPD for gypsum products Economic quality ■■ Criterion: Building related life-cycle costs → Cost-effective Knauf Drywalling Sociocultural and functional quality ■■ Criterion: Space efficiency → Slim.knauf-blue. Knauf Systemkomponenten or other productsoder expressly von Knauf recommended empfohlenenKnauf. functional and technical aspects. options. economic.orgutachterliche reports technical assessments Stellungnahmen to youoder together technische with the Beurteilungen. The stated information represents current state-of-the-art Knauf technology. Germany knauf-direkt@knauf. und bauphysikalischen and characteristic Eigenschaften buildingvon physics KnaufofSystemen Knauf systems können can nur erreichtbewerden. by Produkten The validity sichergestellt and up-to-datedness ist.15/0/Dbl/FB All technical changes reserved. All amendments. bauphysikalische design and (Brandschutz structural requirements und Schallschutz). Nachweise ist zu beachten. including those of excerpts. Mit specifications The gekennzeichnete marked with Angaben offer bieten additional zusätzliche application Ausführungsmöglichkeiten. social. → Knauf Drywalling is fully compliant Special note All construction Die im Detailblattvariants. All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areas. These and all application instructions have to be adhered to separately by the installer. All rights reserved. floor-space enhancing Knauf metal stud partition systems ■■ Criterion: Suitability for conversion → Flexible Knauf Drywalling LEED Materials and resources ■■ Credit: Recycled Content → Recycled content in Knauf boards (e. special notes Information on sustainability of Knauf Products and Metal Stud Partition Systems Building assessment systems ensure the sustainable quality of buildings and constructional structures by a detailed assessment of ecological.de www. require our expressed permission. Personen und/oder Behörden abzustimmen. ???.de Technical quality ■■ Criterion: Fire protection → Comprehensive fire protection know-how ■■ Criterion: Sound insulation → Exceeding the demands of the standard with Knauf sound installation ■■ Criteria: Ease of dismantling and recycling. The entire state of approved engineering rules. Certificate ofstellen Usability wir Ihnen on request. On the basis erfasstof sind.de/eng/08. Abweichung We can provide bewertetthewerden documentation können. Die Gültigkeit of the undstated Aktualität proofs derhave angegebenen to be considered.knauf. solely ensuredwenn with die the ausschließliche exclusive use ofVerwendung Knauf system von components. The certification systems of the DGNB (Deutsches Gütesiegel Nachhaltiges Bauen). Knauf products and Metal Stud Partition systems can positively influence many of these criteria. reprints and photocopies. guidelines. the W11. and sound insulation) are considered.de -details Ausgabe and??/??? statedenthaltenen products inKonstruktionsvarianten. Knauf Direct Technical Advisory Service: Knauf Gips KG Am Bahnhof 7. such asDokumente surveyors’ wie z. unserer technischen we assume Bewertungen that these gehen markedwir design davonsolutions aus.g. and thosekonstruktive regarding building und statische physics Anforderungen (fire protectionberücksichtigt. Our warranty is expressly limited to our products in flawless condition. dass candiese be assessed Ausführunas agen non-significant als nicht wesentliche divergence. Only the current printed instructions are valid.de W11. which are notdie directly nicht included unmittelbar in the vom Certificate Verwendof barkeitsnachweis Usability. at the timeZusätzlich of issue. . Die on which dieser this Einschätzung assessment zugrundeliegenden is based. FGD gypsum) ■■ Credit: Regional Materials → Short transport routes provided by the extensive network of Knauf manufacturing facilities Detailed information on request and on the internet under: www. and authorised das Vorliegen in advance einer in nicht consultation wesentlichen between Abweichung the persons vor responsible Bauausführung for fire mit den für denand/or protection Brandschutz the relevant verantwortlichen authorities.de Knauf Metal Stud Partitions Information on sustainability. our technical Auf Basisassessments. Zeitpunkt to German gültigen building bauaufsichtlichen legislation. gern zusammen We recommend mit demthat Verwenda nonbarkeitsnachweis significant divergence zur Verfügung. and structural statischenproperties. and rules of craftsmanship are not included herewith. Insind addition. Die angegebenen The stated constructional konstruktiven. B. BNB (Bewertungssystem Nachhaltiges Bauen) and LEED (Leadership in Energy and Environmental Design) are of particular relevance in Germany. 97346 Iphofen. valid Nachweisen.W11.de Knauf Metal Ausführungsdetails Stud Partitions -und edition aufgeführten 08/2015Produksystem te entsprechen data sheet fully comply den jeweils with zu thediesem proofs acc.