KM

March 22, 2018 | Author: Jagannath Mohanta | Category: Switch, Fuse (Electrical), Power Supply, Components, Electrical Components


Comments



Description

Return To MAIN INDEXCircuit Breakers Disconnect Switches, Molded Case Switches Overview Instantaneous Trip Circuit Breakers, NZMH 4-...-OBI-CNA Motor Disconnect Switches, NZMH 4-...-CNA Accessories 8/2 8/4 8/5 8/6 80 A 125 A Inverse time Circuit Breakers, NZM(H) 6(B)-.../ZM6A-...NA Instantaneous Trip Circuit Breakers, NZM(H) 6(B)- OBI-CNA Motor Disconnect Switches, NZM(H) 6(B)-../ZM6-...-CNA Motor Disconnect Switches, N 6-...-CNA Accessories 8/12 8/13 8/14 8/15 8/16 250 A Inverse time Circuit Breakers, NZM 12-.../ZM12(A)(V)-...NA Motor Disconnect Switches, N 12-...-CNA Accessories 1000 A 8/32 8/33 8/34 150 A Overview NZM 7.....-NA Inverse time Circuit Breakers, NZM 7(A)-...S-NA(-M8) Molded Case Switches, NZM 7-...-NA(-M8) Accessories 8/40 8/44 8/45 8/46 600 A Overview NZM 10.....-NA Inverse time Circuit Breakers, NZM 10-...(N)(S)(H)-NA Instantaneous Trip Circuit Breakers, NZM 10-...OBI-CNA Molded Case Switches, NZM 10-...-N/B-NA Components for NZM 10...-NA Circuit Breakers Accessories 8/54 8/58 8/60 8/61 8/62 8/64 Trip Curves Technical Data 8/72 8/77 Dimensions 8/84 1 For Immediate Delivery call KMParts.com at (866) 595-9616 8/1 Circuit Breakers Disconnect Switches, Molded Case Switches Inverse time Circuit Breakers, NZM(H) 9-.../ZM9A-...NA Instantaneous Trip Circuit Breakers, NZM(H) 9-...-OBI-CNA Motor Disconnect Switches, NZM(H) 9-../ZM9-...-CNA Motor Disconnect Switches, N 9-...-CNA Accessories 8/22 8/23 8/24 8/25 8/26 8 Circuit Breakers Type NZM...-(C)NA Ratings Overview 1 2 3 UL / CSA / CE / IEC/EN 60 947 4 5 Inverse Time Circuit Breakers Frame Rating UL/ CSA Interrupting Ratings kA RMS SYM @ Amps Thermal-Magnetic Trip UL 489/CSA 22.2 No. 5.1; IEC/EN 60 947-2 NZM 6B-.../ZM 6A-...-NA NZMH 6-.../ZM6A-...-NA Fuseless Current Limiting 15 - 125 15 - 125 240 VAC 480 VAC 600 VAC 25 100 25 65 14 25 NZM 7A-...N-NA1) 25 - 150 65 25 — Circuit Breakers Disconnect Switches, Molded Case Switches NZM 9-.../ZM 9A-...-NA NZMH 9-.../ZM9A-...-NA Fuseless Current Limiting 70 - 250 70 - 250 30 200 25 85 18 42 Solid State Trip UL 489/CSA 22.2 No. 5.1; IEC/EN 60 947-2 NZM 10-...N/ZM 10(A)-...-NA NZM 10-...S/ZM 10(A)-...-NA NZM 10-...H/ZM 10(A)-...-NA Fuseless Current Limiting With trip delay feature for selectivity in networks NZM 10-...N/ZM 10V(A)-...-NA NZM 10-...S/ZM 10V(A)-...-NA 200 - 600 200 - 600 200 - 600 65 100 200 42 65 100 35 42 50 8 200 - 600 200 - 600 65 100 42 65 35 42 NZM 12-.../ZM 12(A)-...-NA2) With trip delay feature for selectivity in networks NZM 12-.../ZM 12V-...-NA2) 300 - 1000 65 65 50 300 - 1000 65 65 50 1) Type NZM 7... currently UL/CSA only. IEC 60 947-2 Conformity in preparation. 2) Type NZM 12... UL/CSA only. All Inverse time Circuit Breakers are UL Listed and CSA Certified, in compliance with IEC/EN 60 947-2 (Circuit Breakers) and CE Marked. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. 8/2 For Immediate Delivery call KMParts.com at (866) 595-9616 UL / CSA / CE / IEC/EN 60 947 1 Circuit Breakers/Disconnect/Molded Case Switches Ratings Overview 2 3 4 5 Instantaneous Trip Circuit Breakers Frame Rating UL/ CSA Interrupting Ratings kA RMS SYM @ Amps 240 VAC 480 VAC 600 VAC Instantaneous Trip Type Circuit Breakers UL 489/CSA 22.2 No. 5.1 NZMH 4-...-OBI-CNA NZMH 4-...-OBI-Form CDN NZM 6B-.../ZM 6-...-OBI-CNA NZMH 6-.../ZM 6-...-OBI-CNA NZM 9-.../ZM 9-...-OBI-CNA NZMH 9-.../ZM 9-...-OBI-CNA NZM 10-...N/ZM-...-OBI-NA NZM 10-...H/ZM-...-OBI-NA 2.1 - 18 2.1 - 18 0.6 - 125 33 - 125 63 - 250 63 - 250 400 - 600 400 - 600 Motor Disconnect Switches UL 508/CSA 22.2 Nr. 14, IEC/EN 60 947-2, CE HP rated, with adjustable thermal and magnetic trips NZMH 4-...-CNA 1) UL / CSA Short Circuit Ratings 4 - 80 15 - 125 15 - 125 63 - 250 63 - 250 100 25 100 30 200 25 25 65 25 85 25 14 25 18 42 NZM 6B-.../ZM 6-...-CNA NZMH 6-.../ZM 6-...-CNA NZM 9-.../ZM 9-...-CNA NZMH 9-.../ZM 9-...-CNA Motor Disconnect Switches UL 508/CSA 22.2 Nr. 14, IEC/EN 60 947-3, CE HP rated, without trip elements N6-...-CNA N9-...-CNA N12-...-CNA 2) 150 250 1200 10 10 42 10 10 42 10 10 42 Molded Case Switches UL 1087, CSA 22.2 Nr. 5.2, IEC/EN 60 947-3, CE Without trip elements NZM 7-...-NA(-M8) NZM 10-...N/B-NA 200 600 25 25 25 25 18 25 1) NZMH 4-...-CNA in the range 4 - 16 Amps, UL/CSA only. 2) N12-...-CNA, UL/CSA only. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. For Immediate Delivery call KMParts.com at (866) 595-9616 8/3 Circuit Breakers Disconnect Switches, Molded Case Switches UL Recognized and CSA Certified Instantaneous Trip circuit breakers no longer carry interrupting ratings as stand-alone devices. Per the intent of NEC Article 430-52, an instantaneous trip circuit breaker shall be used only if part of a listed combination motor controller. Short circuit ratings are, therefore, established and valid only for the listed combination motor controller assembly and associated housing or enclosure. Consult Section 3 of this catalog for Combination Motor Controller short circuit ratings as standard starters featuring Type NZM Instantaneous Trip Circuit Breakers. Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZM Instantaneous Trip Circuit Breakers. 8 Short circuit interrupting ratings are.120 100.80 64 . they provide motor short circuit protection as part of a listed combination motor controller that includes coordinated motor overload protection....Instantaneous Trip Type NZMH 4-..1 3.32 28 ..7 6.. . 200 NZMH 4-2.20 18 ..Molded Case Circuit Breakers . The NZMH 4 instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current ratings of up to 100kA @ 480VAC. Molded Case Switches Instantaneous Trip Circuit Breakers Up to 600Y/347 V AC..-OBI-CNA (18 Amps) Amps $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List 6. 1-12-OBI-CNA NZMH 4-3.. 200 NZMH 4-2...32 28 . 120-OBI-FORM CDN NZMH 4-18.. 120-OBI-CNA NZMH 4-18... Consult Section 3 of this catalog for Combination Motor Controller short circuit ratings as standard starters featuring Type NZM Instantaneous Trip Circuit Breakers.80 64 .... 6-32-OBI-CNA NZMH 4-10..-OBI.. 8/4 For Immediate Delivery call KMParts. 200-OBI-CNA Circuit Breakers Disconnect Switches.com at (866) 595-9616 . Molded Case Circuit Breakers are UL Recognized (UL 489) and CSA Certified (22.. therefore. 1-12-OBI-FORM CDN NZMH 4-3...6 10 12 15 18 6. Example: NZMH 4-18-200-OBI-CNA Note: . 80-OBI-FORM CDN NZMH 4-15.1) Instantaneous Trip type Circuit Breakers with an adjustable magnetic trip function.7 6.... CSA Certified only 2. 7-20-OBI-CNA NZMH 4-6. 50-OBI-CNA NZMH 4-12. established and valid only for the listed combination motor controller assembly and associated housing or enclosure..Line and Load field-wiring terminals for cable connection supplied as standard.. 5.12 11.. .2 Nr.20 18 .Operating Handle supplied separately.-OBI-Form CDN (18 Amps) 8 Type NZMH 4. UL/CSA 2...50 42 ... Consult page 8/8 for available handle types. Ordering Information: State type from Column 4. Per NEC.-OBI. Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZMH Instantaneous Trip Circuit Breakers. 80-OBI-CNA NZMH 4-15. 7-20-OBI-FORM CDN NZMH 4-6. 200-OBI-FORM CDN NZMH 4-...120 100.Consult page 8/6-11 for additional accessories. 50-OBI-FORM CDN NZMH 4-12.1 3.50 42 .... 6-32-OBI-FORM CDN NZMH 4-10..6 10 12 15 18 NZMH 4-..12 11.. 1 2 3 4 5 UL/CSA Frame Rating Continuous Current Rating Adjustable Magnetic Trip Range Type Price Amps Instantaneous Trip Circuit Breakers Up to 480 V AC. which makes them suitable internationally as inverse time molded case circuit breakers with adjustable thermal and magnetic trips. NZMH 4-63-CNA and NZMH 4-80-CNA Disconnect Switches are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers). In addition they are suitable for group applications per the intent of NEC 430-53 and CEC part 1.UL/CSA.-CNA (80 Amps) 8 . HP rated manual motor disconnects with built-in thermal trips for motor overload protection. Consult page 8/8 for available handle types. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings..-CNA Motor Disconnect Switch 4–6 6 – 10 10 – 16 16 – 25 25 – 40 40 – 63 63 – 80 40 – 80 60 – 120 100 – 200 160 – 320 260 – 500 400 – 800 600 – 1000 1 1/2 2 3 5 10 20 25 1 1/2 3 5 7 1/2 10 20 30 3 5 10 15 30 40 60 5 7 1/2 10 20 40 60 75 NZMH 4-6-CNA NZMH 4-10-CNA NZMH 4-16-CNA NZMH 4-25-CNA NZMH 4-40-CNA NZMH 4-63-CNA NZMH 4-80-CNA Type NZMH 4. Rule 28-206. NEC/CEC Group Application ratings: Maximum Group Fuse or Circuit Breaker Listed Branch Circuit Protective Fuse Amps 600 Listed Branch Circuit Protective Breaker Amps 600 UL/CSA Short Circuit Current Rating RMS Sym Rating @ 240VAC 100 kA 480VAC 25 kA 600VAC 25 kA Types NZMH 4-25-CNA. IEC/EN 60 947-2 1 2 3 4 5 Motor Disconnect Switches Type NZMH 4-.2 Nr.. Example: NZMH 4-25-CNA Note: . NZMH 4-40-CNA.. For Immediate Delivery call KMParts.Operating Handle supplied separately. Ordering Information: State type from Column 4.Line and Load field-wiring terminals for cable connection supplied as standard.11 for additional accessories... .com at (866) 595-9616 8/5 Circuit Breakers Disconnect Switches.. Molded Case Switches NZMH 4-. They also feature an adjustable magnetic trip to provide additional protection in case of short circuits.Consult page 8/6 ..-CNA 6 Frame Rating Adjustable Adjustable Thermal Magnetic Trip Range Range for motor overload protection Amps Amps Motor rating Type Price 200 V 230 V 460 V 575 V HP HP HP HP $ See Price List See Price List See Price List See Price List NZMH 4-.-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22. An adjustable dial on the front of the switch (refer to column 2) can be set to the Motor Full Load Current. . 14) as 3 pole.. Refer to diagrams below for further details: 8 NHI Position of auxiliary contacts Main Contacts: Closed Open Same as main contacts See Price List Trip Indicating Auxiliary Contacts See Price List Handle operated Early-Make Auxiliary Contacts Circuit Breakers Disconnect Switches. short-circuit. Dashes indicate incompatibility. contact set but can be field modified as 2 N.) L1L2L3 AHI L1L2L3 RHI Switching OFF I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI Tripped position + I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI Ordering Information: Auxiliary Contacts must be ordered with device.C. Type AHI. or 2 N. Molded Case Switches VHI Same contact position in both OFF and Tripped position of the device. This makes them ideal for load shedding purposes or in conjunction with voltage trips in control circuits. overcurrents or other tripping functions such as voltage trips. They operate simultaneously with the main contacts. Note: Field mounting of contacts is allowed with use of kits. Type VHI... are standard auxiliary contacts. are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. 8/6 For Immediate Delivery call KMParts. They work independently of the normal ON and OFF operations of the device. Add below suffix.O.O. 1 2 3 4 5 Contacts Type To be ordered with device only. VHI. Price Notes See Price List 12 16 14 18 2 2 +NHI 22-NZM 4/6-NA See Price List N. They can be typically used for signalling or switching auxiliary circuits such as a control circuit. They can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes.O. position of the device..C. See Price List See Price List 25/27 21/23 1 1 +AHI-NZMH 4-NA 26/28 22/24 45/47 41/43 1 1 +RHI-NZMH 4-NA 46/48 42/44 Type NHI. Consult Moeller Electric for information..Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts and Accessories for NZMH 4.... and 1 N. switching only when the device has tripped due to overloads. Standard Auxiliary Contacts $ Combination possibilities of auxiliary contacts: NHI VHI AHI G G — G — G G — — 11 15 13 17 See Price List 35/37 31/33 1 1 +VHI-NZMH 4-NA See Price List Early-Make Auxiliary Contacts RHI — — G 36/38 32/34 Dots in each row represent the types which can be combined together. Type RHI. shunt or undervoltage trips. Example: + VHI-NZMH 4-NA. AHI RHI Switching ON I L1L2L3 NHI L1L2L3 VHI Operates only when Same contact position in both ON and Tripped device is tripped (overload. AHI and RHI are supplied as 1 N. shortly after the handle has left the OFF position. are trip indicating auxiliary contacts. N. Add type from Column 3. contacts. They operate in advance of the main contacts. are handle operated Early Make auxiliary contacts.C.com at (866) 595-9616 .... Shunt Trips cannot be mounted together with Undervoltage Trips. Undervoltage Trips cannot be mounted together with Shunt Trips. Example: + U-NZM 4/6(480V. They are rated for continuous duty.Molded Case Circuit Breakers and Disconnect Switches Voltage Trips for the NZMH 4. DC 24V +A-NZM 4/6 (24VDC) See Price List Undervoltage Trips Non-delayed 52 U < 51 See Price List DC 24V +U-NZM 4/6 (24VDC) Ordering Information: Voltage trips must be ordered with device.g. to disconnect the main switch in Emergency-Stop circuits. They are rated for short time duty only.com at (866) 595-9616 See Price List See Price List AC AC AC AC AC 120V 60Hz 208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz +U-NZM 4/6 (120V 60Hz) +U-NZM 4/6 (208V 60Hz) +U-NZM 4/6 (240V 60Hz) +U-NZM 4/6 (480V 60Hz) +U-NZM 4/6 (600V 60Hz) Undervoltage Trips will electrically trip the device open under power loss and can be used for control interlocking purposes e. Power can be applied to the undervoltage trip using VHI early-make auxiliary contacts in series with the undervoltage trip coil. Short time actuation can be achieved by using the NHI auxiliary contact ahead in series with the shunt trip coil. See Price List See Price List See Price List 8/7 Circuit Breakers Disconnect Switches. Add below suffix. Add type from Column 4. For Immediate Delivery call KMParts.. Molded Case Switches See Price List See Price List See Price List See Price List 8 . 60Hz). Price Notes $ See Price List See Price List See Price List See Price List See Price List Shunt Trips Short-time duty rating AC 53 51 120V 60Hz 208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz +A-NZM 4/6 (120V 60Hz) +A-NZM 4/6 (208V 60Hz) +A-NZM 4/6 (240V 60Hz) +A-NZM 4/6 (480V 60Hz) +A-NZM 4/6 (600V 60Hz) AC AC AC AC Shunt Trips are typically used to electrically trip the device from a remote location.. 1 2 3 4 5 6 Rated Control Voltage V/Hz Type To be ordered with device only. . just add a “+” in front of the Type number. SA-NZM 6 8 Mechanical Interlock For mechanical interlocking of two devices... NZM(H) 6(B).. H 4U Black NZMH 4. Order separately.. IEC IP 55 Door coupling rotary handle. KV-2 NZM 4 Ordering Information: Specify Type from Column 5.. Can be field modified for setting in ON position.. Circuit Breakers Disconnect Switches.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZMH 4. Molded Case Switches Gray NZMH 4.... NZM(H) 6(B).. Extends shaft length by 266 mm. Door/cover interlocking supplied standard set in OFF position.400 mm.. NZMH 4.+ (tripped) ... Requires two handles... 3 distinct Handle positions: 0FF . 12. NZM(H) 6(B). NZMH 4... NZMH 4. one for each switch. H 6-NA Black H 6-SW-NA Red/ Yellow RH 6-NA Extension shaft For mounting depths of 150. For front mounting in doors and covers.. 1 2 3 4 5 6 Color of handle Type Can be used with all devices of Type number Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Handle for open or panel mounted devices Fastens to shaft.. not padlockable Gray NZMH 4.. Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm). NZM(H) 6(B)... NZMH 4. Example: H6-SW-NA If ordering with device. Example: + H6-SW-NA 8/8 For Immediate Delivery call KMParts.ON Red -Yellow version for Emergency-Stop function. NZM(H) 6(B).... A-NZM 6 Switch position indicator Indicates position of switch when panel door is open. NZMH 4.com at (866) 595-9616 .. H 4U-SW Handle for Cover/Door Interlocking Degree of protection UL/NEMA 3R.... 3 distinct Handle positions: 0FF .com at (866) 595-9616 See Price List Insert key number into Type. 5. 8 .g. IEC IP 55 Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm).. Height of letters: 3.+ (tripped) .Molded Case Circuit Breakers and Disconnect Switches Accessories for NZMH 4.. just add a “+” in front of the Type number. Add below suffix Type Price $ See Price List See Price List See Price List NZMH 4. Factory installed only..-NZM 6 See Price List Ordering Information: Specify Type from Column 5. Example: H6-R-SW-NA.R rear operation handles. and 7 mm Blank (for engraving or printing) Main Disconnect Warning plates.. 12.ON Red -Yellow version for Emergency-Stop function. English Inscription: “Main Switch.Open only in OFF position” Silver-colored.5. Order with device. Gray NZMH 4 NZM(H) 6(B) — H 6-R-NA See Price List See Price List Rear operation shafts For side panel mounting where device is only accessible from the rear (e... For Immediate Delivery call KMParts.. + R-NZMH 4 — See Price List Black NZMH 4 NZM(H) 6(B) NZMH 4 NZM(H) 6(B) — H 6-R-SW-NA See Price List Legend Plate (for mounting with operating handle) Silver-colored. No cover/door interlocking provisions. Must be combined with Type H. black lettering Also available in other languages: Afrikaans (81) Finnish (66) Italian (68) Russian (74) Bulgarian (64) Czech (78) French (63) German (61) Norwegian (70) Polish (71) Serbo-Croatian (76) Spanish (77) Danish (65) Greek (69) Portuguese (72) Swedish (75) NZMH 4 NZM(H) 6(B) NZMH 4 NZM(H) 6(B) NZMH 4 NZM(H) 6(B) — — — ZSSOND-NZM 6 ZS60-NZM 6 ZS62-NZM 6 See Price List See Price List Red/ Yellow — RH 6-R-NA See Price List See Price List — Dutch (67) Hungarian (80) Romanian (73) Turkish (79) ZS. If ordering with device. black lettering See Price List Specify desired text. Degree of protection: UL/NEMA 3R. sides of enclosure panels).. Molded Case Switches Operating Handle for rear operation Used with rear operation shaft. Example: + H6-R-SW-NA Note: Items in Column 4 are factory installed and must be ordered with the device. Example: ZS 68-NZM 6 (Inscription in Italian language) See Price List See Price List 8/9 Circuit Breakers Disconnect Switches. 1 2 3 4 5 6 Color of handle Can be used Type with To be ordered with device only. NZMH 4 8/10 For Immediate Delivery call KMParts. terminal cover and Main Switch marking plate. Molded Case Switches Kit includes: Main Disconnect handle for rear operated switches. red in color with yellow backing plate for Emergency-Stop function.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZMH 4.. switches with dual UL/CSA and IEC/EN ratings are suitable for use as Main Disconnect switches in control panels that must be CE marked and designed to comply with the Machinery Directive standard EN 60 204-1. supplied with a steel plate for panel side-mounting. V-NZMH4 Circuit Breakers Disconnect Switches. except that the Main Disconnect handle is black in color with silver backing plate for standard. will provide the necessary accessories to fulfill the Main Disconnect switch function for these applications. just add a “+” in front of the Type number. Example: + V. 1 2 3 4 Type Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Main Disconnect Switch Assembly Kits for CE marked control panels per IEC/EN 60 204-1 Type NZMH 4. EA-NZM 4-SW Ordering Information: Specify Type from Column 3.. V-NZMH 4-SW 8 Kit includes: Same as EA-NZMH 4. Note: In cases where the Main Disconnect switch also fulfills the Emergency-Stop function.. terminal cover and Main Switch marking plate EA-NZM 4 Kit includes: Same as V-NZMH 4. please specify kits containing red handle and yellow backing plate assemblies.com at (866) 595-9616 . Kit includes: Main Disconnect handle with door/cover interlock for front mounting. non-Emergency-Stop function. except that the Main Disconnect handle is black in color with silver backing plate for standard. The kits shown below.. red color handle with yellow backing plate for Emergency-Stop function.NZMH 4 If ordering with device. non-Emergency-Stop function. ordered with the device or separately. Example: V. NZMH 4 8 .NZMH 4 If ordering with device. C-NZMH 4 For Immediate Delivery call KMParts. Can be used at top or bottom. (Rail conforming to the standard EN 50 022).com at (866) 595-9616 8/11 Circuit Breakers Disconnect Switches. Example: V. one cover per side. Molded Case Switches Ordering Information: Specify Type from Column 3. 1 2 3 Type Price $ Provides shock hazard protection in the area of the field wiring power terminals. devices on a DIN rail. just add a “+” in front of the Type number..Molded Case Circuit Breakers and Disconnect Switches Accessories for NZMH 4.. H-NZMH 4 See Price List See Price List See Price List See Price List Terminal Cover Clip For mounting NZMH 4. Example: + V.. Mandatory requirement on the supply side of Main Disconnect switches to provide protection against accidental contact with line side feed.. . 260 – 500.. 400 – 800. 160 – 320. Example: NZM 6B-63/ZM6A-50-NA./ZM 6A-.Consult page 8/16 ../ZM 6A-.-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.. 400 – 800./ZM 6A-. . available as a substitute to standard ratings. Type NZM(H)6(B). 260 – 500. Refer to ordering info below.. Example: NZM 6B-63/ZM6A-50-500-NA Note: . supplied standard with the breaker Adjustable magnetic trip./ZM 6A-. 260 – 500. Molded Case Switches High Interrupting Rating NZMH6-. Both types are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers). 160 – 320. IEC/EN 60 947-2 7 Fixed Thermal Setting Adjustable magnetic trip. 260 – 500.-NA.com at (866) 595-9616 ....... 260 – 500. UL/CSA Current-Limiting circuit breaker 15 20 25 30 35 40 50 60 70 80 90 100 125 160 – 320 160 – 320 160 – 320 260 – 500 260 – 500 400 – 800 400 – 800 400 – 800 600 – 1200 600 – 1200 600 – 1200 600 – 1200 600 – 1200 100 – 200 100 – 200 100 – 200 100 – 200.2 Nr. 260 – 500. 5. 25kA 25kA 14kA NZM 6B-63/ZM 6A-15-NA NZM 6B-63/ZM 6A-20-NA NZM 6B-63/ZM 6A-25-NA NZM 6B-63/ZM 6A-30-NA NZM 6B-63/ZM 6A-35-NA NZM 6B-63/ZM 6A-40-NA NZM 6B-63/ZM 6A-50-NA NZM 6B-63/ZM 6A-60-NA NZM 6B-100/ZM 6A-70-NA NZM 6B-100/ZM 6A-80-NA NZM 6B-100/ZM 6A-90-NA NZM 6B-100/ZM 6A-100-NA NZM 6B-160/ZM 6A-125-NA (125A) 160 – 320 160 – 320 260 – 500 260 – 500 260 – 500 400 – 800 400 – 800 400 – 800 400 – 800 1000 – 2000 Circuit Breakers Disconnect Switches.-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22. thermalmagnetic Circuit Breakers with a fixed thermal and adjustable magnetic trip function. Amps UL/CSA Interrupting ratings (AC. thermalmagnetic Current Limiting Circuit Breakers with a fixed thermal and adjustable magnetic trip function..Line and Load field-wiring terminals for cable connection supplied as standard. 260 – 500. Type NZMH 6-. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. Consult page 8/18 for available handle types.2 Nr... 100 – 200. 5... 60Hz) RMS Sym Amps @ Type Price Amps NZM 6B-.. 160 – 320. (Magnetic Trip range per Column 3). which also makes them suitable internationally as inverse time molded case circuit breakers.-NA 15 20 25 30 35 40 50 60 70 80 90 100 125 Amps 240 V 480 V 600 V Standard $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See See Price List See Price List See Price List See Price List See Price List See Price List See Price List Standard Interrupting Rating 160 – 320 160 – 320 160 – 320 260 – 500 260 – 500 400 – 800 400 – 800 400 – 800 600 – 1200 600 – 1200 600 – 1200 600 – 1200 600 – 1200 100 – 200 100 – 200 100 – 200 100 – 200.. Optional: Select a substitute magnetic trip range from column 4.21 for additional accessories. 260 – 500. Specify it in the Type number by including the number in bold.Operating Handle supplied separately. Ordering Information: State type from Column 6. 100 – 200.-NA 1 2 3 4 5 6 UL/CSA.. 160 – 320. 160 – 320. 160 – 320. 125 Amps Thermal-Magnetic. 100kA 65kA 25kA NZMH 6-63/ZM 6A-15-NA NZMH 6-63/ZM 6A-20-NA NZMH 6-63/ZM 6A-25-NA NZMH 6-63/ZM 6A-30-NA NZMH 6-63/ZM 6A-35-NA NZMH 6-63/ZM 6A-40-NA NZMH 6-63/ZM 6A-50-NA NZMH 6-63/ZM 6A-60-NA NZMH 6-100/ZM 6A-70-NA NZMH 6-100/ZM 6A-80-NA NZMH 6-100/ZM 6A-90-NA NZMH 6-100/ZM 6A-100-NA NZMH 6-160/ZM 6A-125-NA 8 (125A) 160 – 320 160 – 320 260 – 500 260 – 500 260 – 500 400 – 800 400 – 800 400 – 800 400 – 800 1000 – 2000 Type NZM 6B-.1) Inverse Time. 8/12 For Immediate Delivery call KMParts.1) Inverse Time.Inverse Time Circuit Breakers. .Operating Handle supplied separately./ZM6-...Instantaneous Trip type..2000 NZMH 6-63/ZM 6-33-200-OBI-CNA NZMH 6-63/ZM 6-50-500-OBI-CNA NZMH 6-63/ZM 6-60-800-OBI-CNA NZMH 6-100/ZM 6-80-500-OBI-CNA NZMH 6-100/ZM 6-100-1200-OBI-CNA NZMH 6-160/ZM 6-125-2000-OBI-CNA NZMH6-. .800 260 .. Ordering Information: State type from Column 4... Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZMH Instantaneous Trip Circuit Breakers. Consult page 8/18 for available handle types.-OBI.1200 1000 ...-OBI-CNA (125 Amps) High Fault Interrupting Ratings 33 50 60 80 100 125 100 . 1 2 3 4 5 Frame Rating Continuous Current Rating Adjustable Magnetic Trip Range Type Price Amps Amps $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Instantaneous Trip Circuit Breakers Up to 600 V AC./ZM6-...2000 NZM 6B-63/ZM 6-33-200-OBI-CNA NZM 6B-63/ZM 6-50-500-OBI-CNA NZM 6B-63/ZM 6-60-800-OBI-CNA NZM 6B-100/ZM 6-80-500-OBI-CNA NZM 6B-100/ZM 6-100-1200-OBI-CNA NZM 6B-160/ZM 6-125-2000-OBI-CNA 8 ..-OBI-CNA (125 Amps) Type NZM6B-. and NZMH6-.Molded Case Circuit Breakers.-OBI.Consult page 8/16 .-OBI.21 for additional accessories.200 260 ./ZM6-. Molded Case Circuit Breakers are UL Recognized (UL 489) and CSA Certified (22.2 Nr.. . UL/CSA Standard Interrupting Ratings NZM 6B-. Short circuit interrupting ratings are. Example: NZM6B-63/ZM6-33-200-OBI-CNA Note: . Molded Case Switches 33 50 60 80 100 125 100 .com at (866) 595-9616 8/13 Circuit Breakers Disconnect Switches./ZM6-..500 600 ..800 260 .Consult Moeller Electric for Type NZM(H)6(B) Instantaneous Breakers with lower continuous current ratings. established and valid only for the listed combination motor controller assembly and associated housing or enclosure. . they provide motor short circuit protection as part of a listed combination motor controller that includes coordinated motor overload protection. For Immediate Delivery call KMParts.500 600 ./ZM6-... 5.. The NZMH6 instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current ratings of up to 65kA @ 480VAC. Per NEC..500 400 ... therefore. Consult Section 3 of this catalog for Combination Motor Controller short circuit ratings as standard starters featuring Type NZM Instantaneous Trip Circuit Breakers.1) Instantaneous Trip type Circuit Breakers with an adjustable magnetic trip function.1200 1000 ...500 400 ...200 260 .Line and Load field-wiring terminals for cable connection supplied as standard.. 125 Amp NZM(H)6(B)-. /ZM6-. .-CNA Disconnect Switches are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers)./ZM6-.25 25 .-CNA 1 2 3 4 5 UL/CSA. HP rated manual motor disconnects with built-in thermal trips for motor overload protection. IEC/EN 60 947-2 6 Frame Rating Adjustable Thermal Range for motor overload protection Amps Adjustable Magnetic Trip Range Maximum HP Rating 3 Phase @ Type Price Amps 200 V HP 230 V HP 460 V HP 575 V HP Standard $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Standard Short Circuit Ratings NZM 6B-.40 40 .... 14) as 3 pole.63 63 ./ZM6-.. An adjustable dial on the front of the switch (refer to column 2) can be set to the Motor Full Load Current.125 100 – 200 160 – 320 260 – 500 400 – 800 600 – 1200 5 10 20 30 40 7 1/2 10 20 30 40 15 30 40 75 100 20 40 60 100 125 NZMH 6-63/ZM 6-25-200-CNA NZMH 6-63/ZM 6-40-320-CNA NZMH 6-63/ZM 6-63-500-CNA NZMH6-100/ZM 6-100-800-CNA NZMH 6-160/ZM 6-125-CNA Types NZM6B-.../ZM6-.Motor Disconnect Switches Type NZM(H)6)B)-.2 Nr...-CNA 15 ... 8/14 For Immediate Delivery call KMParts. Example: NZM6B-63/ZM6-40-CNA Note: .-CNA Types NZM6B-.40 40 ../ZM6-..-CNA and NZMH6-. Molded Case Switches High Fault Short Circuit Ratings NZMH6-....-CNA and NZMH6-.125 (125 Amps) 160 – 320 260 – 500 400 – 800 600 – 1200 1000 – 2000 5 10 20 30 40 7 1/2 10 20 30 40 15 30 4000 75 100 20 40 60 100 125 NZM 6B-63/ZM 6-25-CNA NZM 6B-63/ZM 6-40-CNA NZM 6B-63/ZM 6-63-CNA NZM 6B-100/ZM 6-100-CNA NZM 6B-160/ZM 6-125-2000-CNA with optional lower magnetic trip values: 15 ..40 40 .. Consult page 8/18 for available handle types. Per NEC.-CNA NZMH6-./ZM6-.. They also feature an adjustable magnetic trip to provide additional protection in case of short circuits......100 100 ...125 160 – 320 260 – 500 400 – 800 600 – 1200 1000 – 2000 5 10 20 30 40 7 1/2 10 20 30 40 15 30 40 75 100 20 40 60 100 125 NZMH 6-63/ZM 6-25-CNA NZMH 6-63/ZM 6-40-CNA NZMH 6-63/ZM 6-63-CNA NZMH 6-100/ZM 6-100-CNA NZMH 6-160/ZM 6-125-2000-CNA with optional lower magnetic trip values: (125 Amps) 8 Type 15 ..21 for additional accessories.. which makes them suitable internationally as inverse time molded case circuit breakers with adjustable thermal and magnetic trips..Line and Load field-wiring terminals for cable connection supplied as standard.40 40 ../ZM6-...125 100 – 200 160 – 320 260 – 500 400 – 800 600 – 1200 5 10 20 30 40 7 1/2 10 20 30 40 15 30 40 75 100 20 40 60 100 125 NZM 6B-63/ZM 6-25-200-CNA NZM 6B-63/ZM 6-40-320-CNA NZM 6B-63/ZM 6-63-500-CNA NZM 6B-100/ZM 6-100-800-CNA NZM 6B-160/ZM 6-125-CNA Circuit Breakers Disconnect Switches. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.63 63 .. UL/CSA Short Circuit Current Rating RMS Sym Rating @ 240VAC 480VAC 600VAC 25 kA 100 kA 25 kA 65 kA 14 kA 25 kA NZM6B-.Consult page 8/16 .../ZM6-.-CNA 15 . .-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.100 100 .63 63 ..Operating Handle supplied separately. Ordering Information: State type from Column 5.25 25 .63 63 .25 25 .25 25 .100 100 ..100 100 ./ZM6-.com at (866) 595-9616 . Branch Circuit Overcurrent protection devices must be provided separately. Consult page 8/16 – 21 for additional accessories. Consult page 8/18 for available handle types.. .-CNA 63 100 150 (150 Amps) 20 30 40 25 40 60 50 75 100 60 100 125 N 6-63-CNA N 6-100-CNA N 6-160-CNA Type N6. Example: N 6-100-CNA Note: .UL/CSA.... 14) as 3 pole. .com at (866) 595-9616 8/15 Circuit Breakers Disconnect Switches. which makes them suitable internationally as Main Disconnect switches in a broad range of industrial applications. use in combination with a listed magnetic contactor.For direct-on-line switching of motors. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. + “Tripped”) and they can be equipped with voltage trip accessories such as shunt trip and undervoltage trip coils.Operating Handle supplied separately.-CNA Disconnect Switches are also CE Marked and in Conformity with IEC/EN 60 947-3 (Switch-Disconnectors). ON. Molded Case Switches 8 .2 Nr. N6.Line and Load field-wiring terminals for cable connection supplied as standard. .. Ordering Information: State type from Column 5... Their switching mechanism has 3 positions (OFF. UL/CSA Short Circuit Rating @ 600VAC: 10 kA RMS Sym. 150 Amps Type N6-. HP rated non-automatic manual motor disconnects without any overload or short circuit tripping elements.. IEC/EN 60 947-3 1 2 3 Motor Disconnect Switches. For Immediate Delivery call KMParts.-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22.-CNA 4 5 Frame Rating Continuous Current Rating Maximum HP Rating 3 Phase @ Type Price Amps 200 V HP 230 V HP 460 V HP 575 V HP $ See Price List See Price List See Price List See Price List Motor Disconnect Switches N6-. They work independently of the normal ON and OFF operations of the device. Refer to diagrams below for further details: 8 NHI Position of auxiliary contacts Main Contacts: Closed Open Same as main contacts See Price List Trip Indicating Auxiliary Contacts See Price List Handle operated Early-Make Auxiliary Contacts Circuit Breakers Disconnect Switches..) L1L2L3 RHI Switching OFF I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI Tripped position + I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI VHI and AHI-NZM 6 operate in similar fashion during switching ON and OFF. This makes them ideal for load shedding purposes or in conjunction with voltage trips in control circuits. N. Ordering Information: Auxiliary Contacts must be ordered with device. short-circuit. Type RHI...Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B).. They can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes. They operate simultaneously with the main contacts. Add below suffix. Add type from Column 3. Dashes indicate incompatibility. are trip indicating auxiliary contacts.. See Price List See Price List 22 24 26 28 21 25 2 Form C (Change over) Contacts +AHI 002-NZM 6-NA 42 44 46 48 41 45 2 Form C (Change over) Contacts +RHI 002-NZM 6-NA Type NHI.. shunt or undervoltage trips. They operate in advance of the main contacts. They can be typically used for signalling or switching auxiliary circuits such as a control circuit. Type VHI. are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. overcurrents or other tripping functions such as voltage trips.. Price Notes See Price List 12 16 14 18 2 2 +NHI 22-NZM 4/6-NA See Price List N..C. are handle operated Early Make auxiliary contacts. AHI Same contact position in both ON and Tripped position of the device.. Type AHI. 8/16 For Immediate Delivery call KMParts. are standard auxiliary contacts.com at (866) 595-9616 .O. Molded Case Switches VHI Same contact position in both OFF and Tripped position of the device. Standard Auxiliary Contacts $ Combination possibilities of auxiliary contacts: NHI VHI AHI G G — G — G G — — 11 15 13 17 See Price List 32 34 36 38 31 35 2 Form C (Change over) Contacts +VHI 002-NZM 6-NA See Price List Early-Make Auxiliary Contacts RHI — — G Dots in each row represent the types which can be combined together. switching only when the device has tripped due to overloads. 1 2 3 5 5 Contacts Type To be ordered with device only. Example: + VHI 002-NZM 6-NA.. shortly after the handle has left the OFF position. Switching ON I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI RHI Operates only when device is tripped (overload. They are rated for continuous duty. For Immediate Delivery call KMParts. Add below suffix. $ See Price List See Price List See Price List See Price List Shunt Trips Short-time duty rating 53 51 AC AC AC AC AC DC 120V 60Hz 208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz 24V +A-NZM 4/6 (120V 60Hz) +A-NZM 4/6 (208V 60Hz) +A-NZM 4/6 (240V 60Hz) +A-NZM 4/6 (480V 60Hz) +A-NZM 4/6 (600V 60Hz) +A-NZM 4/6 (24VDC) See Price List See Price List Shunt Trips are typically used to electrically trip the device from a remote location.. Undervoltage Trips cannot be mounted together with Shunt Trips. 1 2 3 4 5 6 Rated Control Voltage V/Hz Type Price Notes To be ordered with device only. 60Hz). to disconnect the main switch in Emergency-Stop circuits. Short time actuation can be achieved by using the NHI auxiliary contact ahead in series with the shunt trip coil.com at (866) 595-9616 8/17 Circuit Breakers Disconnect Switches. Power can be applied to the undervoltage trip using VHI early-make auxiliary contacts in series with the undervoltage trip coil. Ordering Information: Voltage trips must be ordered with device. Shunt Trips cannot be mounted together with Undervoltage Trips. Example: + U-NZM 4/6(480V. They are rated for short time duty only..Molded Case Circuit Breakers and Disconnect Switches Voltage Trips for NZM(H)6(B). Undervoltage Trips Continuous duty rating 52 U < 51 AC AC AC AC AC DC 120V 60Hz 208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz 24V +U-NZM 4/6 (120V 60Hz) +U-NZM 4/6 (208V 60Hz) +U-NZM 4/6 (240V 60Hz) +U-NZM 4/6 (480V 60Hz) +U-NZM 4/6 (600V 60Hz) +U-NZM 4/6 (24VDC) See Price List See Price List Undervoltage Trips will electrically trip the device open under power loss and can be used for control interlocking purposes e.g. Add type from Column 4. Molded Case Switches See Price List See Price List See Price List See Price List 8 . . one for each switch. just add a “+” in front of the Type number. 12. NZM(H)6(B). NZM(H) 6(B) N6.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM(H)6(B)... NZM(H) 6(B) N6. Example: + H6-SW-NA 8/18 For Immediate Delivery call KMParts..ON Red -Yellow version for Emergency-Stop function. H 6U H 6U-SW Handle for Cover/Door Interlocking Degree of protection UL/NEMA 3R.. 1 2 3 4 5 6 Color of handle Can be used Type with all devices of Type number Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Handle for open or panel mounted devices Fastens to shaft.. Order separately..... 3 distinct Handle positions: 0FF . Can also be used with the mechanical interlock. Accommodates up to 3 padlocks (hasp size 1/4”. Door/cover interlocking supplied standard set in OFF position.. A limit switch (Type AT0) can also be installed for signalling or electrical interlocking purposes. Extends shaft length by 266 mm... Can be field modified for setting in ON position.. N6.. Example: H6-SW-NA If ordering with device... SVB-NZM 6 8 Switch position indicator Indicates position of switch when panel door is open. not padlockable Gray Black NZM(H)6(B).. N6.+ (tripped) ..... Padlocking accessory Enables the device to be padlocked OFF when the panel door is open. A-NZM 6 See Price List See Price List See Price List See Price List Circuit Breakers Disconnect Switches.. SA-NZM 6 See Price List See Price List NZMH 4 NZM(H) 6(B) N6. Molded Case Switches ..... Maintenance Handle To actuate the device when the panel door is open.. H6UZ Mechanical Interlock For mechanical interlocking of two devices. Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm).. NZM(H) 6(B) N6. Gray NZMH 4 NZM(H) 6(B) N6. Requires two handles... NZMH 4 NZM(H) 6(B) N6. H 6-NA Black H 6-SW-NA Red/ Yellow RH 6-NA Extension shaft For mounting depths of 150 – 400 mm... 6 – 8mm). KV-2 NZM 6 Ordering Information: Specify Type from Column 5. For front mounting in doors and covers.com at (866) 595-9616 See Price List See Price List NZMH 4 NZM(H) 6(B) N6. NZMH 4 NZM(H) 6(B) N6.. Only one extension shaft possible.. IEC IP 55 Door coupling rotary handle.. black lettering See Price List Specify desired text.g. and 7 mm Blank (for engraving or printing) NZMH 4 NZM(H) 6(B) N6. 12. English Inscription: “Main Switch. Example: H6-R-SW-NA. 3 distinct Handle positions: 0FF . No cover/door interlocking provisions..... Example: ZS61-NZM 6 (Inscription in German language) Ordering Information: Specify Type from Column 5. Height of letters: 3. just add a “+” in front of the Type number.R-NA rear operation handles. + R-NZMH 6 — See Price List Black NZMH 4 NZM(H) 6(B) N6. sides of enclosure panels). NZMH 4 NZM(H) 6(B) N6. NZMH 4 NZM(H) 6(B) N6. Degree of protection: UL/NEMA 3R. — H 6-R-SW-NA See Price List Legend Plate (for mounting with operating handle) Silver-colored.ON Red -Yellow version for Emergency-Stop function. N6. Example: + H6-R-SW-NA Note: Items in Column 4 are factory installed and must be ordered with the device..... 8 .Open only in OFF position” Silver-colored..... Order with device. NZMH 4 NZM(H) 6(B) N6. Molded Case Switches Operating Handle for rear operation Used with rear operation shaft. 1 2 3 4 5 6 Color of handle Can be used with Type To be ordered with device only.-NZM 6 See Price List Insert key number into Type.+ (tripped) .5.com at (866) 595-9616 See Price List Afrikaans (81) Finnish (66) Italian (68) Russian (74) Bulgarian (64) Czech (78) French (63) German (61) Norwegian (70) Polish (71) Serbo-Croatian (76) Spanish (77) See Price List Main Disconnect Warning plates. Factory installed only.. Must be combined with Type H..... Danish (65) Greek (69) Portuguese (72) Swedish (75) Dutch (67) Hungarian (80) Romanian (73) Turkish (79) — ZSSOND-NZM 6 See Price List See Price List Red/ Yellow — RH 6-R-NA See Price List — ZS60-NZM 6 See Price List Also available in other languages: — ZS.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM(H)6(B).. black lettering — ZS62-NZM 6 See Price List 8/19 Circuit Breakers Disconnect Switches.. — H 6-R-NA See Price List See Price List Rear operation shafts For side panel mounting where device is only accessible from the rear (e... For Immediate Delivery call KMParts.. Gray NZMH 4 NZM(H) 6(B) N6. 5.. IEC IP 55 Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm). NZMH 4 NZM(H) 6(B) N6. Add below suffix Type Price $ See Price List See Price List See Price List NZM(H) 6(B).. If ordering with device. will provide the necessary accessories to fulfill the Main Disconnect switch function for these applications.NZM 6 8/20 For Immediate Delivery call KMParts. red color handle with yellow backing plate for Emergency-Stop function. switches with dual UL/CSA and IEC/EN ratings are suitable for use as Main Disconnect switches in control panels that must be CE marked and designed to comply with the Machinery Directive standard EN 60 204-1. please specify kits containing red handle and yellow backing plate assemblies. Molded Case Switches Kit includes: Main Disconnect handle with door/cover interlock for front mounting.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM(H)6(B). 1 2 3 4 Type When ordered separately without device Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Main Disconnect Switch Assembly Kits for CE marked control panels per IEC/EN 60 204-1 Type NZM(H)6(B)-. V-NZM 6 Kit includes: Main Disconnect handle for rear operated switches. except that the Main Disconnect handle is black in color with silver backing plate for standard.. non-Emergency-Stop function. non-Emergency-Stop function.. Example: V. terminal cover and Main Switch marking plate EA-NZM 6 8 Kit includes: Same as V-NZM 6..com at (866) 595-9616 . ordered with the device or separately. Example: + V.NZM 6 If ordering with device. Note: In cases where the Main Disconnect switch also fulfills the Emergency-Stop function. just add a “+” in front of the Type number. except that the Main Disconnect handle is black in color with silver backing plate for standard. V-NZM 6-SW Kit includes: Same as EA-NZM 6. terminal cover and Main Switch marking plate.. red in color with yellow backing plate for Emergency-Stop function. supplied with a steel plate for panel side-mounting. EA-NZM 6-SW Ordering Information: Specify Type from Column 3. The kits shown below. Circuit Breakers Disconnect Switches. Specify Type suffix.. — H-NZM 6 See Price List See Price List See Price List Control Circuit Tap-Off Terminals Ordering Information: Accessory in Column 2 can only be ordered with device. 3 connections top and bottom. Example: H-NZM 6 If ordering with device. Example: + H-NZM 6 For Immediate Delivery call KMParts. Mandatory requirement on the supply side of Main Disconnect switches to provide protection against accidental contact with line side feed. Factory addition only. must be ordered with device.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM(H)6(B).com at (866) 595-9616 8/21 Circuit Breakers Disconnect Switches. +ST-NA — Terminal Cover Provides shock hazard protection in the area of the field wiring power terminals.. Molded Case Switches See Price List See Price List See Price List See Price List 8 . Can be used at top or bottom. Add suffix shown below Type Price $ See Price List See Price List See Price List Supplementary terminals attached to main terminals. just add a “+” in front of the Type number. Example: + ST-NA Specify Type from Column 3. one cover per side. 1 2 3 4 Type To be ordered with device only. UL/CSA Interrupting available as a substitute to ratings (AC. 8/22 For Immediate Delivery call KMParts.. 200 kA 85 kA 42 kA NZMH 9-250/ZM 9A-70-NA NZMH 9-250/ZM 9A-80-NA NZMH 9-250/ZM 9A-90-NA NZMH 9-250/ZM 9A-100-NA NZMH 9-250/ZM 9A-125-NA NZMH 9-250/ZM 9A-150-NA NZMH 9-250/ZM 9A-175-NA NZMH 9-250/ZM 9A-200-NA NZMH 9-250/ZM 9A-225-NA NZMH 9-250/ZM 9A-250-NA 400 – 800 400 – 800 1000 – 2000 1000 – 2000 1000 – 2000 1000 – 2000 8 (250A) Type NZM 9-.. Refer to ordering info RMS Sym Amps @ below./ZM 9A-. Consult page 8/28 for available handle types. 250 Amps Thermal-Magnetic. 600 – 1200. IEC/EN 60 947-2 7 Fixed Thermal Setting Adjustable magnetic trip.1) Inverse Time.Line and Load field-wiring terminals for cable connection supplied as standard. Type Price Amps NZM 9-. 600 – 1200. UL/CSA Current-Limiting circuit breaker 70 80 90 100 125 150 175 200 225 250 600 – 1200 600 – 1200 600 – 1200 1000 – 2000 1000 – 2000 1000 – 2000 1600 – 2400 1600 – 2400 1600 – 2400 1600 – 2400 400 – 800 400 – 800 400 – 800 600 – 1200.com at (866) 595-9616 .1) Inverse Time. Type NZMH 9-.-NA 1 2 3 4 5 6 UL/CSA.Consult page 8/26 .-NA. which also makes them suitable internationally as inverse time molded case circuit breakers.. Both types are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers). 600 – 1200.. 600 – 1200. 60 Hz) standard ratings.. 30 kA 25 kA 18 kA NZM 9-250/ZM 9A-70-NA NZM 9-250/ZM 9A-80-NA NZM 9-250/ZM 9A-90-NA NZM 9-250/ZM 9A-100-NA NZM 9-250/ZM 9A-125-NA NZM 9-250/ZM 9A-150-NA NZM 9-250/ZM 9A-175-NA NZM 9-250/ZM 9A-200-NA NZM 9-250/ZM 9A-225-NA NZM 9-250/ZM 9A-250-NA 400 – 800 400 – 800 1000 – 2000 1000 – 2000 1000 – 2000 1000 – 2000 (250A) Circuit Breakers Disconnect Switches. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. Type NZM(H)9.-NA 70 80 90 100 125 150 175 200 225 250 Amps Amps 240 V 480 V 600 V Standard $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Standard Interrupting Rating 600 – 1200 600 – 1200 600 – 1200 1000 – 2000 1000 – 2000 1000 – 2000 1600 – 2400 1600 – 2400 1600 – 2400 1600 – 2400 400 – 800 400 – 800 400 – 800 600 – 1200.31 for additional accessories. 5. 600 – 1200./ZM 9A-.Operating Handle supplied separately. Molded Case Switches High Interrupting Rating NZMH9-...2 Nr.. 600 – 1200.....2 Nr. thermal-magnetic Current Limiting Circuit Breakers with a fixed thermal and adjustable magnetic trip function.-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.. Example: NZM 9-250/ZM9A-250-NA (Magnetic Trip range per Column 3). 600 – 1200 600 – 1200. 5.. 600 – 1200 600 – 1200.Inverse Time Circuit Breakers./ZM 9A-./ZM 9A-.. Specify it in the Type number by including the number in bold. Example: NZM 9-250/ZM9A-250-2000-NA Note: . Optional: Select a substitute magnetic trip range from column 4. . thermal-magnetic Circuit Breakers with a fixed thermal and adjustable magnetic trip function. 600 – 1200.. 600 – 1200. ... Ordering Information: State type from Column 6. supplied standard with the breaker Adjustable magnetic trip. ../ZM9-.31 for additional accessories. 5./ZM9-.-OBI-CNA (250 Amps) 400 – 800 600 – 1200 1000 – 2000 1600 – 2400 1600 – 2400 NZMH 9-250/ZM 9-63-800-OBI-CNA NZMH 9-250/ZM 9-100-1200-OBI-CNA NZMH 9-250/ZM 9-160-2000-OBI-CNA NZMH 9-250/ZM 9-200-2400-OBI-CNA NZMH 9-250/ZM 9-250-2400-OBI-CNA See Price List See Price List Type NZM9-. Short circuit interrupting ratings are... Consult Section 3 of this catalog for Combination Motor Controller short circuit ratings as standard starters featuring Type NZM... Molded Case Switches See Price List See Price List See Price List See Price List 8 . 250 Amp Type NZM(H)9-..1) Instantaneous Trip type Circuit Breakers with an adjustable magnetic trip function.. .Instantaneous Trip type. and NZMH9-.2 Nr. 1 2 3 4 5 Frame Rating Continuous Current Rating Adjustable Magnetic Trip Range Type Price Amps Amps $ See Price List See Price List See Price List Instantaneous Trip Circuit Breakers Up to 600 V AC.-OBI. . Instantaneous Trip Circuit Breakers.Operating Handle supplied separately.. For Immediate Delivery call KMParts. Per NEC. they provide motor short circuit protection as part of a listed combination motor controller that includes coordinated motor overload protection. Consult page 8/28 for available handle types./ZM9-.../ZM9-. Instantaneous Trip Circuit Breakers. The NZMH 9 instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current ratings of up to 85 kA @ 480 V AC... Molded Case Circuit Breakers are UL Recognized (UL 489) and CSA Certified (22. Ordering Information: State type from Column 4.-OBI... Example: NZM 9-250/ZM9-250-2400-OBI-CNA Note: ...Consult page 8/ 26 ./ZM9-.. UL/CSA Standard Interrupting Ratings 63 100 160 200 250 NZM 9-. Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZMH..... established and valid only for the listed combination motor controller assembly and associated housing or enclosure..com at (866) 595-9616 8/23 Circuit Breakers Disconnect Switches.-OBI-CNA (250 Amps) 400 – 800 600 – 1200 1000 – 2000 1600 – 2400 1600 – 2400 NZM 9-250/ZM 9-63-800-OBI-CNA NZM 9-250/ZM 9-100-1200-OBI-CNA NZM 9-250/ZM 9-160-2000-OBI-CNA NZM 9-250/ZM 9-200-2400-OBI-CNA NZM 9-250/ZM 9-250-2400-OBI-CNA See Price List High Fault Interrupting Ratings 63 100 160 200 250 NZMH 9-.Molded Case Circuit Breakers.-OBI.Line and Load field-wiring terminals for cable connection supplied as standard.. therefore....... -CNA Disconnect Switches are CE Marked and in Conformity with IEC/EN 60 947-2 (Circuit Breakers).For direct-on-line switching of motors.com at (866) 595-9616 ./ZM 9-..-CNA 1 2 3 4 5 UL/CSA. Type UL/CSA Short Circuit Current Rating RMS Sym Rating @ 240 V AC 480 V AC 600 V AC 30 kA 200 kA 25 kA 85 kA 18 kA 42 kA NZM 9-... Ordering Information: State type from Column 5./ZM 9-.Motor Disconnect Switches Type NZM(H)9-. Example: NZM 9-250/ZM 9-200-CNA Note: ..... ..-CNA 63 – 100 100 – 160 160 – 200 200 – 250 600 – 1200 1000 – 2000 1600 – 2400 1600 – 2400 30 50 60 75 30 60 75 75 75 125 150 150 100 150 200 225 NZM 9-250/ZM 9-100-CNA NZM 9-250/ZM 9-160-CNA NZM 9-250/ZM 9-200-CNA NZM 9-250/ZM 9-250-CNA (250A) with optional lower magnetic trip values: 63 – 100 400 – 800 30 100 – 160 600 – 1200 50 160 – 200 60 1000 – 2000 200 – 250 75 1000 – 2000 30 60 75 75 75 125 150 150 100 150 200 225 NZM 9-250/ZM 9-100-800-CNA NZM 9-250/ZM 9-160-1200-CNA NZM 9-250/ZM 9-200-2000-CNA NZM 9-250/ZM 9-250-2000-CNA Circuit Breakers Disconnect Switches. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. They also feature an adjustable magnetic trip to provide additional protection in case of short circuits.. . 8/24 For Immediate Delivery call KMParts. Molded Case Switches High Fault Short Circuit Ratings NZMH 9-.Line and Load field-wiring terminals for cable connection supplied as standard./ZM9-..-CNA 63 – 100 100 – 160 160 – 200 200 – 250 600 – 1200 1000 – 2000 1600 – 2400 1600 – 2400 30 50 60 75 30 60 75 75 75 125 150 150 100 150 200 225 NZMH 9-250/ZM 9-100-CNA NZMH 9-250/ZM 9-160-CNA NZMH 9-250/ZM 9-200-CNA NZMH 9-250/ZM 9-250-CNA with optional lower magnetic trip values: (250A) 63 – 100 100 – 160 160 – 200 200 – 250 400 – 800 600 – 1200 1000 – 2000 1000 – 2000 30 50 60 75 30 60 75 75 75 125 150 150 100 150 200 225 NZMH 9-250/ZM 9-100-800-CNA NZMH 9-250/ZM 9-160-1200-CNA NZMH 9-250/ZM 9-200-2000-CNA NZMH 9-250/ZM 9-250-2000-CNA 8 Types NZM 9-.../ZM9-. Per NEC... HP rated manual motor disconnects with built-in thermal trips for motor overload protection.. which makes them suitable internationally as inverse time molded case circuit breakers with adjustable thermal and magnetic trips...-CNA and NZMH 9-.31 for additional accessories.Consult page 8/ 26 ./ZM 9-../ZM 9-...../ZM 9-... Branch Circuit Overcurrent protection devices must be provided separately. use in combination with a listed magnetic contactor.2 Nr.-CNA NZMH 9-..Operating Handle supplied separately......-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22. . An adjustable dial on the front of the switch (refer to column 2) can be set to the Motor Full Load Current.../ZM9-.-CNA and NZMH 9-. Consult page 8/28 for available handle types.../ZM 9-.-CNA Types NZM 9-. IEC/EN 60 947-2 6 Frame Rating Adjustable Thermal Range for motor overload protection Amps Adjustable Magnetic Trip Range Maximum HP Rating 3 Phase @ Type Price Amps 200 V HP 230 V HP 460 V HP 575 V HP Standard $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Standard Short Circuit Ratings NZM 9-.. 14) as 3-pole.. . use in combination with a listed magnetic contactor.-CNA Motor Disconnect Switches 250 200 V 230 V HP HP 460 V HP 575 V HP $ See Price List See Price List See Price List See Price List 60 75 150 200 N 9-250-CNA (250A) Type N9. . + “Tripped”) and they can be equipped with voltage trip accessories such as shunt trip and undervoltage trip coils. . ON.. which makes them suitable internationally as Main Disconnect switches in a broad range of industrial applications. For Immediate Delivery call KMParts.-CNA 4 5 Frame Rating Continuous Current Rating Maximum HP Rating 3 Phase @ Type Price Amps N9-.Consult page 8/ 26 .. . Their switching mechanism has 3 positions (OFF. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings.. 250 Amps Type N9-.com at (866) 595-9616 8/25 Circuit Breakers Disconnect Switches. 14) as 3 pole.2 Nr..Operating Handle supplied separately. Consult page 8/28 for available handle types. N9.Line and Load field-wiring terminals for cable connection supplied as standard.. IEC/EN 60 947-3 1 2 3 Motor Disconnect Switches.-CNA Disconnect Switches are also CE Marked and in Conformity with IEC/EN 60 947-3 (Switch-Disconnectors). Molded Case Switches 8 . Ordering Information: State type from Column 5: N 9-250-CNA Note: .For direct-on-line switching of motors.31 for additional accessories... HP rated nonautomatic manual motor disconnects without any overload or short circuit tripping elements. UL/CSA Short Circuit Rating @ 600 V AC: 10 kA RMS Sym.UL/CSA.-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22. Accessories for NZM(H) 9... Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts 1 2 3 4 5 Contacts Type To be ordered with device only. Add below suffix. Price Notes N.O. N.C. $ Combination possibilities of auxiliary contacts: NHI VHI AHI l l — l — l l — — See Price List See Price List Standard Auxiliary Contacts 12 16 14 18 2 2 +NHI 22-NZM 9 11 15 13 17 See Price List 32 34 36 38 31 35 2 Form C +VHI 002-NZM 9 (Changeover) Contacts See Price List Early-Make Auxiliary Contacts RHI — — l Dots in each row represent the types which can be combined together. Dashes indicate incompatibility. See Price List See Price List 22 24 26 28 21 25 2 Form C +AHI 002-NZM 9 (Changeover) Contacts 42 44 46 48 41 45 2 Form C +RHI 002-NZM 9 (Changeover) Contacts Type NHI... are standard auxiliary contacts. They operate simultaneously with the main contacts. They can be typically used for signalling or switching auxiliary circuits such as a control circuit. Type VHI... are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. This makes them ideal for load shedding purposes or in conjunction with voltage trips in control circuits. Type AHI... are handle operated Early Make auxiliary contacts. They operate in advance of the main contacts, shortly after the handle has left the OFF position. They can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes. Type RHI... are trip indicating auxiliary contacts. They work independently of the normal ON and OFF operations of the device, switching only when the device has tripped due to overloads, overcurrents or other tripping functions such as voltage trips. Refer to diagrams below for further details: 8 Position of auxiliary contacts Main Contacts: Closed Open NHI Same as main contacts See Price List Trip Indicating Auxiliary Contacts See Price List Handle operated Early-Make Auxiliary Contacts Circuit Breakers Disconnect Switches, Molded Case Switches VHI Same contact position in both OFF and Tripped position of the device. Switching ON I L1L2L3 NHI L1L2L3 VHI AHI RHI Operates only when Same contact position in both ON and Tripped device is tripped (overload, short-circuit, position of the device. shunt or undervoltage trips.) L1L2L3 AHI L1L2L3 RHI Switching OFF I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI Tripped position + I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI Ordering Information: Auxiliary Contacts must be ordered with device. Add type from Column 3. Example: + VHI 002-NZM 9. 8/26 For Immediate Delivery call KMParts.com at (866) 595-9616 Molded Case Circuit Breakers and Disconnect Switches Voltage Trips for NZM(H) 9... 1 2 3 4 5 6 Rated Control Voltage Type To be ordered with device only. Add below suffix. V/Hz Price Notes $ See Price List See Price List See Price List See Price List Shunt Trips 100% Continuous duty rating 53 51 DC 24 V +A-NZM 9 (24V DC) See Price List See Price List AC AC AC AC AC 120 V 60 Hz 208 V 60 Hz 240 V 60 Hz 480 V 60 Hz 600 V 60 Hz +A-NZM 9 (120V 60Hz) +A-NZM 9 (208V 60Hz) +A-NZM 9 (240V 60Hz) +A-NZM 9 (480V 60Hz) +A-NZM 9 (600V 60 Hz) Shunt Trips are typically used to electrically trip the device from a remote location. The A-NZM 9... series is rated for 100% continuous duty. If desired, automatic disconnection of the shunt trip coil can be achieved by using the NHI auxiliary contact in series with the coil. Shunt Trips cannot be mounted together with Undervoltage Trips. Undervoltage Trips 52 U < 51 DC 24 V +U-NZM 9 (24VDC) See Price List See Price List See Price List See Price List AC AC AC AC AC 120 V 60 Hz 208 V 60 Hz 240 V 60 Hz 480 V 60 Hz 600 V 60 Hz +U-NZM 9 (120V 60Hz) +U-NZM 9 (208V 60Hz) +U-NZM 9 (240V 60Hz) +U-NZM 9 (480V 60Hz) +U-NZM 9 (600V 60Hz) Undervoltage Trips will electrically trip the device open under power loss and can be used for control interlocking purposes e.g. to disconnect the main switch in EmergencyStop circuits. They are rated for continuous duty. Power can be applied to the undervoltage trip using VHI early-make auxiliary contacts in series with the undervoltage trip coil. Undervoltage Trips cannot be mounted together with Shunt Trips. Ordering Information: Voltage trips must be ordered with device. Add type from Column 4. Example: + U-NZM 9 (480V, 60 Hz). For Immediate Delivery call KMParts.com at (866) 595-9616 8/27 Circuit Breakers Disconnect Switches, Molded Case Switches 8 Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM(H) 9... 1 2 3 4 5 6 Color of handle Type Can be used with all devices of Type number Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Fastens to shaft, not padlockable Gray NZM(H) 9... N 9... NZM(H) 9... N 9... H 9U Black H 9U-SW Handle for Cover/Door Interlocking Degree of protection UL/NEMA 3R, 12; IEC IP 55 Door coupling rotary handle. For front mounting in doors and covers. Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm). Door/cover interlocking supplied standard set in OFF position. Can be field modified for setting in ON position. 3 distinct Handle positions: 0FF, + (tripped), ON Red -Yellow version for Emergency-Stop function. Gray NZM(H) 9... N 9... NZM(H) 9... N 9... NZM(H) 9... N 9... H 9-NA Black H 9-SW-NA Red/ Yellow RH 9-NA Extension shaft For mounting depths of 190...400 mm. Extends shaft length by 223 mm. Only one extension shaft possible. Can also be used with the mechanical interlock. NZM(H) 9... N 9... A-NZM 9 Padlocking accessory Enables the device to be padlocked OFF when the panel door is open. Accommodates up to 3 padlocks (hasp size 1/4”, 6 – 8mm). A limit switch (Type AT0) can also be installed for signalling or electrical interlocking purposes. NZM(H) 9... N 9... SVB-NZM 9 8 Switch position indicator Indicates position of switch when panel door is open. NZM(H) 9... N 9... SA-NZM 9 Maintenance Handle To actuate the device when the panel door is open. NZM(H) 9... N 9... H9UZ Mechanical Interlock For mechanical interlocking of two devices. Requires two handles, one for each switch. Order separately. NZM(H) 9... N 9... KV-2 NZM 9 Ordering Information: Specify Type from Column 5. Example: H9-SW-NA If ordering with device, just add a “+” in front of the Type number. Example: + H9-SW-NA 8/28 For Immediate Delivery call KMParts.com at (866) 595-9616 See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Handle for open or panel mounted devices Circuit Breakers Disconnect Switches, Molded Case Switches . NZM(H) 9. + (tripped)..... Example: H9-R-SW-NA. Example: + H9-R-SW-NA Note: Items in Column 4 are factory installed and must be ordered with the device. black lettering Blank (for engraving or printing) Main Disconnect Warning plates. English Inscription: “Main Switch.... If ordering with device..... Factory installed only. N 9. and 7 mm NZM(H) 9. Must be combined with Type H. N 9. N 9.. ON Red -Yellow version for Emergency-Stop function. +R-NZM 9 See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Rear operation shafts Operating Handle for rear operation Used with rear operation shaft. For Immediate Delivery call KMParts.... N 9.... just add a “+” in front of the Type number.. N 9.5.... 3 distinct Handle positions: 0FF. Example: ZS68-NZM 9 (Inscription in Italian language) Ordering Information: Specify Type from Column 5. — H 9-R-NA Legend Plate (for mounting with operating handle) Silver-colored. N 9. Height of letters: 3.Open only in OFF position” Silver-colored. NZM(H) 9.. NZM(H) 9. No cover/door interlocking provisions. Order with device. — ZSSOND-NZM 9 See Price List See Price List Red/ Yellow — RH 9-R-NA — ZS62-NZM 9 — ZS...com at (866) 595-9616 See Price List See Price List See Price List 8/29 Circuit Breakers Disconnect Switches.. NZM(H) 9. black lettering Also available in other languages: Afrikaans (81) Finnish (66) Italian (68) Russian (74) Bulgarian (64) Czech (78) French (63) German (61) Norwegian (70) Polish (71) Serbo-Croatian (76) Spanish (77) Danish (65) Greek (69) Portuguese (72) Swedish (75) Dutch (67) Hungarian (80) Romanian (73) Turkish (79) NZM(H) 9.. N 9.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM(H) 9..-NZM 9 Insert key number into Type. 5... sides of enclosure panels).. Degree of protection: UL/NEMA 3R... IEC IP 55 Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm). N 9. — ZS60-NZM 9 See Price List Specify desired text.. NZM(H) 9. Gray NZM(H) 9.g... Add below suffix Type Price $ For side panel mounting where device is only accessible from the rear (e. Molded Case Switches Black — H 9-R-SW-NA See Price List See Price List 8 . 12..R rear operation handles. 1 2 3 4 5 6 Color of handle Can be used Type with all devices of Type number To be ordered with device only. Kit includes: Main Disconnect handle with door/cover interlock for front mounting. terminal cover and Main Switch marking plate EA-NZM 9 8 Kit includes: Same as V-NZM 9.Molded Case Circuit Breakers and Disconnect Switches Handle kits for NZM(H) 9. switches with dual UL/CSA and IEC/EN ratings are suitable for use as Main Disconnect switches in control panels that must be CE marked and designed to comply with the Machinery Directive standard EN 60 204-1. terminal cover and Main Switch marking plate. non-Emergency-Stop function.. 1 2 3 4 Type Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List for CE marked control panels per IEC/EN 60 204-1 Type NZM(H) 9-. V-NZM 9 Kit includes: Main Disconnect handle for rear operated switches. except that the Main Disconnect handle is black in color with silver backing plate for standard.NZM 9 If ordering with device.NZM 9 8/30 For Immediate Delivery call KMParts. red color handle with yellow backing plate for Emergency-Stop function.. EA-NZM 9-SW Ordering Information: Specify Type from Column 3. supplied with a steel plate for panel side-mounting.. V-NZM 9-SW Kit includes: Same as EA-NZM 9. except that the Main Disconnect handle is black in color with silver backing plate for standard. will provide the necessary accessories to fulfill the Main Disconnect switch function for these applications. Molded Case Switches . ordered with the device or separately. red in color with yellow backing plate for Emergency-Stop function. Example: V.com at (866) 595-9616 See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Main Disconnect Switch Assembly Kits Circuit Breakers Disconnect Switches. just add a “+” in front of the Type number. non-Emergency-Stop function. please specify kits containing red handle and yellow backing plate assemblies. Example: + V. The kits shown below.. Note: In cases where the Main Disconnect switch also fulfills the Emergency-Stop function. must be ordered with device. Molded Case Switches 8 .Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM(H) 9. Example: + ST Specify Type from Column 3. Example: H-NZM 9 If ordering with device... — H-NZM 9 See Price List See Price List See Price List Ordering Information: Accessory in Column 2 can only be ordered with device. Factory addition only. 3 connections top and bottom. just add a “+” in front of the Type number. 1 2 3 4 Type To be ordered with device only.com at (866) 595-9616 8/31 Circuit Breakers Disconnect Switches. Example: + H-NZM 9 For Immediate Delivery call KMParts. Specify Type suffix. Can be used at top or bottom. one cover per side. Add suffix shown below Type Price $ See Price List See Price List See Price List Control Circuit Tap-Off Terminals Supplementary terminals attached to main terminals. Mandatory requirement on the supply side of Main Disconnect switches to provide protection against accidental contact with line side feed. +ST — Terminal Cover Provides shock hazard protection in the area of the field wiring power terminals. 000 600 – 7200 800 – 9600 1000 – 12..000 1200 – 12. Ordering Information: State type from Column 6..... 60Hz) RMS Sym Amps @ Type Price Amps Type NZM 12-. Molded Case Switches (1000 A) Adjustable Long Time Response Setting Type NZM 12-....-NA are UL Listed (UL 489) and CSA Certified (22. Type NZM 12.000 2000 – 20./ZM 12A-.. 5. The time delay response is adjustable from 0 to 1000 milliseconds..000 2000 – 20. Solid State Trip Circuit Breakers with a fixed or adjustable Long Time Response and adjustable instantaneous pick-up range.. Refer to technical data for range of suitable conductor cross-sections.000 1600 – 16.000 — — — — — — 65 kA 65 kA 50 kA NZM 12-630/ZM 12A-400-NA NZM 12-630/ZM 12A-500-NA NZM 12-630/ZM 12A-600-NA NZM 12-800/ZM 12A-700-NA NZM 12-800/ZM 12A-800-NA NZM 12-1250/ZM 12A-1000-NA Circuit Breakers Disconnect Switches../ZM 12(A)-.39 for additional accessories.2 Nr. Example: NZM 12-1250/ZM 12A-1000-NA.2 Nr. .000 1600 – 16. 1000 Amps Solid State Trip./ZM 12 V-..000 1600 – 16. Consult page 8/36 for available handle types.Inverse Time Circuit Breakers.com at (866) 595-9616 . .000 1600 – 16.000 — — — 65 kA 65 kA 50 kA NZM 12-630/ZM 12-600-NA NZM 12-800/ZM 12-800-NA NZM 12-1250/ZM 12-1000-NA (1000 A) Adjustable Long Time response setting and Short-Time Delay pick-up for selectivity Type NZM 12-.-NA 300 – 600 400 – 800 500 – 1000 1200 – 12. Type NZM 12-.1) and have an additional short time delay pick-up range for selectivity in energy distribution networks.000 1200 – 12../ZM 12-.../ZM 12 V-.-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22.Operating Handle supplied separately... 8/32 For Immediate Delivery call KMParts.000 2000 – 20.-NA 300 – 600 400 – 800 500 – 1000 1200 – 12. Note: ....-NA 400 500 600 700 800 1000 Amps Amps 240 V 480 V 600 V Standard $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Fixed Long Time Response Setting 1200 – 12.Consult page 8/34 .1) Inverse Time.000 65 kA 65 kA 50 kA NZM 12-630/ZM 12 V-600-NA NZM 12-800/ZM 12 V-800-NA NZM 12-1250/ZM 12 V-1000-NA 8 (1000 A) Type NZM 12-. 5.-NA 1 2 3 4 5 6 7 UL/CSA Long Time Response Current Setting Adjustable instantaneous Pick-up Setting Adjustable Short Time Delay Pick-up setting for selectivity in networks Time delay Range: 0 – 1000 ms UL/CSA Interrupting ratings (AC.Line and Load field-wiring terminals for cable connection supplied as standard.. com at (866) 595-9616 8/33 Circuit Breakers Disconnect Switches. 1) N 12-1200-CNA is supplied standard with bolt-on connection only. .. Example: N 12 -1200-CNA + K 240AL-NZM 12-O (for top mounted terminals.-CNA Disconnect Switches are UL recognized (UL 508) and CSA certified (22..-CNA 4 5 Frame Rating Continuous Current Rating Maximum HP Rating 3 Phase @ Type Price Amps N12-. ON. .For direct-on-line switching of motors.Consult page 8/34 . Molded Case Switches 8 .-CNA Motor Disconnect Switches 600 800 1000 1200 200 V 230 V HP HP 460 V HP 575 V HP $ See Price List See Price List See Price List See Price List 200 250 250 300 250 300 300 450 450 600 600 1000 600 750 750 1000 N 12-630-CNA N 12-800-CNA N 12-1000-CNA N 12-1200-CNA 1) Type N 12.UL/CSA..39 for additional accessories. Field-wiring terminals for conductor hook-up (up to 4 x 500 kcmil. Example: N 12-800-CNA Note: ...Operating Handle supplied separately. UL/CSA Short Circuit Rating @ 600VAC: 42 kA RMS Sym.Line and Load field-wiring terminals for cable connection supplied as standard.2 Nr. Add the following suffixes to the Type number. 1200 Amps Type N12-. IEC/EN 60 947-3 1 2 3 Motor Disconnect Switches. + “Tripped”) and they can be equipped with voltage trip accessories such as shunt trip and undervoltage trip coils. Their switching mechanism has 3 positions (OFF. HP rated non-automatic manual motor disconnects without any overload or short circuit tripping elements. 14) as 3 pole. . Cu or Al) can be supplied but must be ordered with the device.. set of three) + K 240AL-NZM 12-U (for bottom mounted terminals. set of three) See price list for adder. use in combination with a listed magnetic contactor. For Immediate Delivery call KMParts. Ordering Information: State type from Column 4. Consult page 8/36 for available handle types. This makes them ideal for load shedding purposes or in conjunction with voltage trips in control circuits... They work independently of the normal ON and OFF operations of the device.. shortly after the handle has left the OFF position. Type NHI. Switching ON I L1L2L3 NHI L1L2L3 VHI AHI RHI Operates only when Same contact position in both ON and Tripped device is tripped (overload. They can be typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes.C. Price Notes N. N.O... They operate in advance of the main contacts.com at (866) 595-9616 .. overcurrents or other tripping functions such as voltage trips.. Type RHI. $ See Price List See Price List Standard Auxiliary Contacts 12 16 14 18 1) 2 2 +NHI 22-NZM 12 11 15 13 17 Combination possibilities of auxiliary contacts: NHI VHI AHI G G — G — G RHI G G 32 36 38 2 1 +VHI 21-NZM 12 See Price List See Price List See Price List See Price List Early-Make Auxiliary Contacts 31 35 37 Dots in each row represent the types which can be combined together. It is an optional accessory only for the non-automatic N 12-. switching only when the device has tripped due to overloads. are trip indicating auxiliary contacts.-NA Molded Case Circuit Breakers. Add type from Column 3. Refer to diagrams below for further details: 8 Position of auxiliary contacts Main Contacts: Closed Open NHI Same as main contacts VHI Same contact position in both OFF and Tripped position of the device... Type VHI.) L1L2L3 AHI L1L2L3 RHI Switching OFF I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI Tripped position + I L1L2L3 NHI L1L2L3 VHI L1L2L3 AHI L1L2L3 RHI Ordering Information: Auxiliary Contacts must be ordered with device.. Type AHI. position of the device.... Example: + VHI 21-NZM 12. Add below suffix. short-circuit. are standard auxiliary contacts. 1 2 3 4 5 Contacts Type To be ordered with device only. They can be typically used for signalling or switching auxiliary circuits such as a control circuit. are Early Make auxiliary contacts and lead the main contacts when switching ON as well as switching OFF. are handle operated Early Make auxiliary contacts.. 8/34 For Immediate Delivery call KMParts. shunt or undervoltage trips. They operate simultaneously with the main contacts. +AHI 21-NZM 12 21 25 27 1 See Price List Trip Indicating Auxiliary Contacts 42 46 48 2 41 45 47 See Price List Handle operated Early-Make Auxiliary Contacts 22 26 28 2 1 Circuit Breakers Disconnect Switches. Molded Case Switches +RHI 21-NZM 12 1) The NHI 22-NZM 12 auxiliary contact comes standard with all versions of the NZM 12-. Dashes indicate incompatibility.../ZM 12.Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM 12.-CNA disconnect switches and must be ordered with the device if desired. 60Hz) For Immediate Delivery call KMParts. automatic disconnection of the shunt trip coil can be achieved by using the NHI auxiliary contact in series with the coil.. Undervoltage Trips cannot be mounted together with Shunt Trips... Molded Case Switches See Price List See Price List 8 . Undervoltage Trips 52 U < 51 AC AC AC AC AC 120V 60Hz 208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz +U-NZM 12 (120V 60Hz) +U-NZM 12 (208V 60Hz) +U-NZM 12 (240V 60Hz) +U-NZM 12 (480V 60Hz) +U-NZM 12 (600V 60Hz) See Price List DC 24V +U-NZM 12 (24VDC) See Price List Undervoltage Trips will electrically trip the device open under power loss and can be used for control interlocking purposes e. Power can be applied to the undervoltage trip using VHI early-make auxiliary contacts in series with the undervoltage trip coil. Example: + U-NZM 12 (480V. series is rated for 100% continuous duty. V/Hz Price Notes $ See Price List See Price List See Price List See Price List Shunt Trips 100% Continuous duty rating 53 51 See Price List DC 24 V +A-NZM 12 (24V DC) See Price List AC AC AC AC AC 120V 60Hz 208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz +A-NZM 12 (120V 60Hz) +A-NZM 12 (208V 60Hz) +A-NZM 12 (240V 60Hz) +A-NZM 12 (480V 60Hz) +A-NZM 12 (600V 60Hz) Shunt Trips are typically used to electrically trip the device from a remote location.com at (866) 595-9616 8/35 Circuit Breakers Disconnect Switches. If desired. Shunt Trips cannot be mounted together with Undervoltage Trips.g.Molded Case Circuit Breakers and Disconnect Switches Voltage Trips for NZM 12. Add below suffix. They are rated for continuous duty.. Ordering Information: Voltage trips must be ordered with device. to disconnect the main switch in EmergencyStop circuits. The A-NZM 12. Add type from Column 4. 1 2 3 4 5 6 Rated Control Voltage Type To be ordered with device only. 12. KVA-2 NZM 12 N(ZM)12.. H 12U See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Handle for Cover/Door Interlocking Degree of protection UL/NEMA 3R. N(ZM)12. Door/cover interlocking supplied standard set in OFF position. RH 12-NA Extension shaft For mounting depths of 240 – 400 mm... For mechanically interlocking two main incomers with one emergency-supply device e.. Molded Case Switches ..ON Red -Yellow version for Emergency-Stop function. H 12-NA Black N(ZM)12. Can be field modified for setting in ON position. Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm)... not padlockable Gray N(ZM)12. H 12-SW-NA Red/ Yellow N(ZM)12. one for each switch. Handles ordered separately. Requires two handles. N(ZM)12... Example: H 12-SW-NA If ordering with device.. Order separately. KV-2 NZM 12 N(ZM)12.. 3 distinct Handle positions: 0FF . Requires two handles.. one for each switch.. N(ZM)12. For front mounting in doors and covers.g. IEC IP 55 Door coupling rotary handle. Example: + H 12-SW-NA 8/36 For Immediate Delivery call KMParts. Order separately.... A-NZM 12 Switch position indicator Indicates position of switch when panel door is open. 1 2 3 4 5 6 Color of handle Can be used with all devices of Type number Type Price $ Handle for open or panel mounted devices Fastens to shaft.. H 12U-SW See Price List See Price List Circuit Breakers Disconnect Switches.... SA-NZM 12 Maintenance Handle To actuate the device when the panel door is open. Only one extension shaft possible. Extends shaft length by 183 mm. For mechanical interlocking of two devices not mounted side by side.com at (866) 595-9616 See Price List See Price List See Price List See Price List 8 See Price List See Price List See Price List See Price List See Price List Black N(ZM)12..+ (tripped) .. KVA-3 NZM 12 Ordering Information: Specify Type from Column 5. in emergency power supply systems. Can also be used with the mechanical interlock. Gray N(ZM)12. H 12UZ Mechanical Interlock For mechanical interlocking of two devices mounted side by side.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM 12. N(ZM)12... just add a “+” in front of the Type number. Dutch (67) Hungarian (80) Romanian (73) Turkish (79) — ZS... Example: ZS63-NZM 12 (Inscription in French language) Ordering Information: Specify Type from Column 5..R rear operation handles. Add below suffix Type Price $ Rear operation shafts For side panel mounting where device is only accessible from the rear (e. Order with device.5. — H 12-R-NA See Price List See Price List See Price List See Price List See Price List Black N(ZM) 12. N(ZM) 12..Open only in OFF position” Silver-colored.com at (866) 595-9616 See Price List See Price List See Price List See Price List 8/37 Circuit Breakers Disconnect Switches. 3 distinct Handle positions: 0FF .-NZM 12 See Price List Insert key number into Type. 5.. +R-NZM 12 See Price List Operating Handle for rear operation Used with rear operation shaft....Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM 12... Height of letters: 3. Molded Case Switches 8 ... black lettering See Price List Specify desired text.ON Red -Yellow version for Emergency-Stop function. black lettering Also available in other languages: Afrikaans (81) Finnish (66) Italian (68) Russian (74) Bulgarian (64) Czech (78) French (63) German (61) Norwegian (70) Polish (71) Serbo-Croatian (76) Spanish (77) Danish (65) Greek (69) Portuguese (72) Swedish (75) N(ZM) 12. Example: + H 12-R-SW-NA Note: Items in Column 4 are factory installed and must be ordered with the device. IEC IP 55 Can be locked in the OFF position with up to three padlocks (hasp thickness 6 – 8 mm). — RH 12-R-NA See Price List N(ZM) 12....... 1 2 3 4 5 6 Color Can be used of with all devices handle of Type number Type To be ordered with device only. Example: H 12-R-SW-NA. — H 12-R-SW-NA (for mounting with operating handle) Silver-colored. English Inscription: “Main Switch. — — — ZSSOND-NZM 12 ZS60-NZM 12 ZS62-NZM 12 See Price List See Price List See Price List Legend Plate See Price List See Price List Red/ Yellow N(ZM) 12. Degree of protection: UL/NEMA 3R. sides of enclosure panels). Factory installed only..g. N(ZM) 12.. N(ZM) 12... Must be combined with Type H. If ordering with device. 12. No cover/door interlocking provisions. and 7 mm Blank (for engraving or printing) Main Disconnect Warning plates.+ (tripped) . Gray N(ZM) 12. just add a “+” in front of the Type number. For Immediate Delivery call KMParts. Various test voltages simulate a short-circuit or an overload condition which would cause the circuit-breaker to trip out. 1 2 3 4 Type To be ordered with device only. 3 connections top and bottom.. 50/60 Hz The portable test unit can be used to verify that the long time. +ST —See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Control Circuit Tap-Off Terminals Terminal Cover Provides shock hazard protection in the area of the field wiring power terminals. are supplied with the unit. Example: + ST Specify Type from Column 3. just add a “+” in front of the Type number. as well as operating instructions.com at (866) 595-9616 . Add suffix shown below Type Price $ Supplementary terminals attached to main terminals. All measuring and connection leads. Specify Type suffix. must be ordered with device. instantaneous and short-time delayed tripping characteristics of the circuit-breaker are operating per preset values. Mandatory requirement on the supply side of Main Disconnect switches to provide protection against accidental contact with line side feed.Molded Case Circuit Breakers and Disconnect Switches Accessories for NZM 12.. Molded Case Switches 8 Ordering Information: Accessory in Column 2 can only be ordered with device. — H-NZM 12 Test Unit for NZM 12 Circuit-Breakers Supply terminal voltage can be selected from 120/220/240 V. Example: H-NZM 12 If ordering with device. — P-NZM Circuit Breakers Disconnect Switches. Factory addition only. Example: + H-NZM 12 8/38 For Immediate Delivery call KMParts. Can be used at top or bottom. one cover per side. Notes For Immediate Delivery call KMParts.com at (866) 595-9616 8/39 Circuit Breakers Disconnect Switches. Molded Case Switches 8 . .Molded Case Circuit Breakers and Switches Type NZM 7. Molded Case Switches 2 4 8 6 1 2 7 5 8/40 For Immediate Delivery call KMParts.com at (866) 595-9616 . Overview UL / CSA / IEC/EN 60 947 / CE 3 Circuit Breakers Disconnect Switches.. com at (866) 595-9616 8/41 Circuit Breakers Disconnect Switches.2 # 5. 1 Molded Case Switch – Page 8/45 600 VAC. CSA certified (C 22.) Standard color: Black.. standard auxiliary contact: For signalling ON and OFF positions Type RHI. Molded Case Switches 8 . Padlockable in the OFF or ON position with up to 3 padlocks (hasp size: 1/4”.2 # 5... (Optional) 2 Auxiliary Contacts – Page 8/46 (Pictured right of toggle switch) Type NHI. To power up the undervoltage trip prior to main contact closing Shunt Trips AC & DC versions With and without Early-Make auxiliary contacts Undervoltage Trips AC & DC versions With and without Early-Make auxiliary contacts 7 Door/Cover Interlocking Rotary Handle – Page 8/50 For cover or door mounting. (Optional. Also available in red-yellow for Emergency-Stop function per CE and IEC/EN 60 204-1 specifications.. IEC/EN: IP 55. trip-indicating auxiliary contact: For signalling the Tripped (“+”) position 6 Rotary Handle – Page 8/50 To operate switch equipped with rotary drive mechanism.. UL Listed (UL 489).2) Conformity with IEC/EN 60 947-3 (Switch-Disconnectors) 5 Rotary Drive Mechanism – Page 8/50 Converts toggle switch operation of the switch into a rotary movement suitable for rotary style operators.1) Conformity with (Circuit Breakers) IEC/EN 60 947-2 (pending) 4 Clip Plate– Page 8/52 Enables mounting of the NZM 7 on a DIN rail conforming to EN 50 022 specifications. Lockable in the OFF position. Early-Make auxiliary contact: For interlocking and load shedding purposes. CSA certified (C 22. 2 Auxiliary Contacts & Voltage Trips – Page 8/47. 4 – 8mm).Molded Case Circuit Breakers and Switches Type NZM 7. Also comes without padlockable feature. 150 Amp rating 25 kA @ 480 VAC Interrupting rating Field installable accessories Supplied with terminals for cable hookup or bolt-on connection. Interlocking feature to prevent opening of door or cover with the switch in the ON position. 3 Terminal Cover – Page 8/53 Provides shock hazard protection against accidental contact with live terminals.. 200 Amp rating Field installable accessories UL Listed (UL 1087).49 (Pictured left of toggle switch) Type VHI.. Mandatory use in Main Disconnect switch applications for CE panels in conformity with IEC/EN 60 204-1 For Immediate Delivery call KMParts... Overview 1 Molded Case Breaker – Page 8/44 480 V AC.. Degree of protection: UL/NEMA 12. ..-NA + R-NZM 7 G G — G — or G — 8 G Dots in each row represent the accessories which can be combined together in the types shown at left....Molded Case Circuit Breakers and Switches Overview of Combination Options for Type NZM 7.... (RHI) G VHI-NZM 7 A-NZM 7 AVHI-NZM 7 U-NZM 7 UHI NZM 7 G or G or G or G or G Molded Case Switches NZM 7. Molded Case Switches G G G or G or G or G or G Molded Case Circuit Breakers + Remote Control Drive G NZM 7(A). Auxiliary contacts (NHI.. All accessories can be field or factory installed....com at (866) 595-9616 ....: Early-Make) Voltage Trips (A.N-NA EK...: Shunt Trip) (AVHI....: Shunt Trip with Early-Make Auxiliary Contact) (U. Circles indicate supplied as standard.. (NHI) Molded Case Circuit Breakers G NZM 7(A). — Dashes indicate incompatibility.: Standard) (RHI.N-NA + R-NZM 7 G — G — or G — Molded Case Switches + Remote Control Drive NZM 7.-NA Circuit Breakers Disconnect Switches.: Undervoltage Trip) (UHI... 8/42 For Immediate Delivery call KMParts......: Undervoltage Trip with Early-Make Auxiliary Contact) EK.: Trip Indicating) (VHI. .N-NA-M8 NZM 7 ...-NA-M8 G or or or G or G G or G or G G — — — — G — — — — G For Immediate Delivery call KMParts. IP 55 Cable Terminals (included as standard) Bolt-on Connection (Optional) RNZM 7 G DA(OV)NZM 7 G HU(Z)NZM 7 G (R)HNZM 7 G HOVNZM 7 G NZM 7(A).Molded Case Circuit Breakers and Switches Overview of Combination Options for Type NZM 7. Remote Control Drive Handle Operators Connection systems Rotary Rotary Drive handle Mechanism Cover/Door Interlocking Rotary handle NEMA/UL Type 12.. Molded Case Switches 8 ...com at (866) 595-9616 8/43 Circuit Breakers Disconnect Switches. . Example: NZM 7A-25S-NA For accessories see pages 8/46 ... 8/44 For Immediate Delivery call KMParts.5 x Iu 6 – 12 x Iu 100kA 50kA 22kA NZM 7-40S-NA-M8 NZM 7-63S-NA-M8 NZM 7-80S-NA-M8 NZM 7-100S-NA-M8 NZM 7-125S-NA-M8 NZM 7-150S-NA-M8 Ordering Information: Specify Type from Column 7.5 x Iu 6 – 12 x Iu 100kA 50kA 22kA NZM 7-40S-NA NZM 7-63S-NA NZM 7-80S-NA NZM 7-100S-NA NZM 7-125S-NA NZM 7-150S-NA Fixed thermal setting and provisions for bolt-on connection Type NZM 7A-..53 in the Main Catalog USA 2000 / 2001 1) Conformity with IEC/EN 60 947-2 pending.. 600 VAC Thermal-Magnetic Type NZM 7..com at (866) 595-9616 .Inverse Time Circuit Breakers.S-NA 40 60 80 100 125 150 — — — — — — 25 – 40 40 – 60 60 – 80 80 – 100 100 – 125 125 – 150 9.S-NA 40 60 80 100 125 150 — — — — — — 25 – 40 40 – 60 60 – 80 80 – 100 100 – 125 125 – 150 9..5 x Iu 100kA 50kA 22kA NZM 7A-25S-NA NZM 7A-30S-NA NZM 7A-35S-NA NZM 7A-40S-NA NZM 7A-50S-NA NZM 7A-60S-NA NZM 7A-70S-NA NZM 7A-80S-NA NZM 7A-90S-NA NZM 7A-100S-NA NZM 7A-125S-NA NZM 7A-150S-NA 60 (150A) 80 100 125 150 Adjustable Range: 6 – 12 x Iu Circuit Breakers Disconnect Switches. 150 Amps. 60Hz) RMS Sym Amps @ 240V 480V 600V Type Price Amps $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Pressure-wire terminals and fixed thermal setting Type NZM 7A-. Molded Case Switches Pressure-wire terminals and adjustable thermal setting Type NZM 7A-..S-NA 40 25 30 35 40 50 60 70 80 90 100 125 150 — — — — — — — — — — — — Fixed: 9..5 x Iu Adjustable Range: 6 – 12 x Iu 100kA 50kA 22kA NZM 7A-25S-NA-M8 NZM 7A-30S-NA-M8 NZM 7A-35S-NA-M8 NZM 7A-40S-NA-M8 NZM 7A-50S-NA-M8 NZM 7A-60S-NA-M8 NZM 7A-70S-NA-M8 NZM 7A-80S-NA-M8 NZM 7A-90S-NA-M8 NZM 7A-100S-NA-M8 NZM 7A-125S-NA-M8 NZM 7A-150S-NA-M8 60 80 8 100 125 150 Adjustable thermal setting and provisions for bolt-on connection Type NZM 7-. IEC/EN 60 947-21) 7 8 Continuous Fixed Thermal Current Setting Rating Iu Amps Amps Adjustable Thermal Setting Magnetic Trip Setting for Instantaneous Response Amps UL/CSA Interrupting ratings (AC.S-NA 1 2 3 4 5 6 UL/CSA..S-NA 40 25 30 35 40 50 60 70 80 90 100 125 150 — — — — — — — — — — — — Fixed: 9. Inverse Time Circuit Breakers, 150 Amps, 480 VAC Thermal-Magnetic Type NZM 7...-NA 1 2 3 4 5 6 UL/CSA, IEC/EN 60 947-21) 7 8 Continuous Fixed Thermal Current Setting Rating Adjustable Thermal Setting Magnetic Trip Setting for Instantaneous Response UL/CSA Interrupting ratings (AC, 60Hz) RMS Sym Amps @ Type Price Iu Amps Amps Amps Amps 240 V 480 V $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Pressure-wire terminals and fixed thermal setting Type NZM 7A-...N-NA 40 25 30 35 40 50 60 70 80 90 100 125 150 — — — — — — — — — — — — Fixed: 9.5 x Iu 65 kA 25 kA NZM 7A-25N-NA NZM 7A-30N-NA NZM 7A-35N-NA NZM 7A-40N-NA NZM 7A-50N-NA NZM 7A-60N-NA NZM 7A-70N-NA NZM 7A-80N-NA NZM 7A-90N-NA NZM 7A-100N-NA NZM 7A-125N-NA NZM 7A-150N-NA 60 (150A) 80 100 Adjustable Range: 6 – 12 x Iu Circuit Breakers Disconnect Switches, Molded Case Switches 125 150 Pressure-wire terminals and adjustable thermal setting Type NZM 7A-...N-NA 40 60 80 100 125 150 — — — — — — 25 – 40 40 – 60 60 – 80 80 – 100 100 – 125 125 – 150 9.5 x Iu 6 – 12 x Iu 65 kA 25 kA NZM 7-40N-NA NZM 7-63N-NA NZM 7-80N-NA NZM 7-100N-NA NZM 7-125N-NA NZM 7-150N-NA Fixed thermal setting and provisions for bolt-on connection Type NZM 7A-...N-NA 40 25 30 35 40 50 60 70 80 90 100 125 150 — — — — — — — — — — — — Fixed: 9.5 x Iu 65 kA 25 kA NZM 7A-25N-NA-M8 NZM 7A-30N-NA-M8 NZM 7A-35N-NA-M8 NZM 7A-40N-NA-M8 NZM 7A-50N-NA-M8 NZM 7A-60N-NA-M8 NZM 7A-70N-NA-M8 NZM 7A-80N-NA-M8 NZM 7A-90N-NA-M8 NZM 7A-100N-NA-M8 NZM 7A-125N-NA-M8 NZM 7A-150N-NA-M8 8 60 80 100 125 150 Adjustable Range: 6 – 12 x Iu Adjustable thermal setting and provisions for bolt-on connection Type NZM 7-...N-NA 40 60 80 100 125 150 — — — — — — 25 – 40 40 – 60 60 – 80 80 – 100 100 – 125 125 – 150 9.5 x Iu 6 – 12 x Iu 65 kA 25 kA NZM 7-40N-NA-M8 NZM 7-63N-NA-M8 NZM 7-80N-NA-M8 NZM 7-100N-NA-M8 NZM 7-125N-NA-M8 NZM 7-150N-NA-M8 Ordering Information: Specify Type from Column 7. Example: NZM 7A-25N-NA. 1) Conformity with IEC/EN 60 947-2 pending. Consult the technical data at the back of this section and Moeller Electric for IEC/EN ratings. 8/44a For Immediate Delivery call KMParts.com at (866) 595-9616 UL/CSA, IEC/EN 60 947-3 1 2 3 Molded Case Switches, 200Amps, 600 VAC Type NZM 7...-NA 4 5 Ampere Rating Type Price Notes Amps With pressure wire terminals for cable connection 60 100 125 150 200 NZM 7-60-NA NZM 7-100-NA NZM 7-125-NA NZM 7-150-NA NZM 7-200-NA See Price List See Price List See Price List See Price List See Price List Molded Case Switches UL/CSA Short Circuit Current Rating: With 225 A Fuse Backup: - 50 kA RMS Sym @ 600 VAC With 250 A Circuit-Breaker Backup: - 25 kA RMS Sym @ 480 VAC - 18 kA RMS Sym @ 600 VAC See Price List Molded Case Switches With provisions for bolt-on connection 60 100 125 150 200 NZM 7-60-NA-M8 NZM 7-100-NA-M8 NZM 7-125-NA-M8 NZM 7-150-NA-M8 NZM 7-200-NA-M8 Type NZM 7(A)-...-NA(M8) Molded Case Circuit Breakers (opposite page) are UL Listed (UL 489) and CSA Certified (22.2 Nr. 5.1) Inverse Time, 150A Thermal-Magnetic Circuit Breakers that are available with either a fixed or adjustable thermal trip feature and an adjustable magnetic trip function. (In Breakers rated 25 to 40 Amp, the magnetic trip function is fixed at 9.5 x 40A (Iu) i.e. 385A). Type NZM 7-...-NA(-M8) Molded Case Switches (shown above) are virtually identical in construction to the Molded Case Circuit Breakers except that they are manual, non-automatic switches without any overload or overcurrent protective features, and are rated up to 200Amps. All Molded Case Switches are UL Listed (UL 1087) and CSA certified (C 22.2 Nr. 5.2). They also are in Conformity with IEC/EN 60 947-3 (SwitchDisconnectors) and are CE marked. (Consult the Technical Data at the end of this section and Moeller Electric for IEC/EN ratings.) Molded Case Switches are tested to determine their acceptability for continuous operation at their marked rated load. In addition, they are tested at six times their full ampere rating to cover motor circuit applications and are suitable for use as motor circuit disconnects per Section 430-109 of the National Electrical Code. Both breakers and switches are supplied as standard with pressure wire terminals to accept cable connection, but are also suitable for bolt-on connections using crimped lugs or straight lengths of Cu busbar (Type suffix “-M8”). Accessories such as voltage trips, auxiliary contacts, rotary handles etc... are common to all NZM 7 circuit breakers and molded case switches and are UL listed and CSA certified for field installation. Ordering Information: Specify Type from Column 3. Example: NZM 7-60-NA. For Immediate Delivery call KMParts.com at (866) 595-9616 8/45 Circuit Breakers Disconnect Switches, Molded Case Switches See Price List See Price List See Price List See Price List 8 Molded Case Circuit Breakers and Switches Auxiliary Contacts for Type NZM 7...-NA 1 2 3 4 5 6 Contact sequence Type Price Notes $ Standard auxiliary contacts Switching simultaneously with the main contacts. They can 1.13 See Price List See Price List See Price List See Price List See Price List See Price List NHI N.O. EK 10 be typically used for signalling, interlocking or switching auxiliary circuits such as a control circuit. Two EK... NHI type contacts can be snap fitted into the Circuit Breaker or Molded Case Switch. 1.14 1.11 1.12 VHI Early-Make auxiliary contacts Leading the main contacts when switching ON as well as switching OFF. Ideal for load shedding purposes or in conjunction with voltage trips in control circuits. 3.13 3.33 See Price List N.C. EK 01 3.14 3.34 RHI Trip-indicating auxiliary contacts Actuating independently of the normal ON and OFF operations of the device, switching only when the device has tripped due to overcurrents or other tripping causes such as those initiated by voltage trips. 4.13 See Price List See Price List 2X E.M. VHI-NZM 7 One VHI...Type contact module per Circuit Breaker or Molded Case Switch. Cannot be used in conjunction with the R-NZM 7 Remote Control Drive. Circuit Breakers Disconnect Switches, Molded Case Switches N.O. EK 10 4.14 4.13 N.C. EK 01 4.14 Auxiliary Contacts are field installable. 8 Auxiliary Contacts and Voltage Trips can be combined as follows: NHI 2 x EK... G G G G G RHI 1 x EK... G G G G G VHI G — — — — A — G — — — AVHI — — G — — U — — — G — U(V)HI — — — — G Ordering information: Specify Type from column 4. Example: EK 10 If ordering with device, just specify a “+” in front of the Type number. Example: + EK 10 Dots in each row represent the types which can be combined together. Dashes indicate incompatibility. 8/46 For Immediate Delivery call KMParts.com at (866) 595-9616 See Price List One EK... RHI type contact (either N.O. or N.C.) can be snap fitted into the Circuit Breaker or Molded Case Switch for trip indication. See Price List 8/47 Circuit Breakers Disconnect Switches.. Dashes indicate incompatibility. L2) N(L-.13 AC/DC1) See Price List 12 24 48 60 110-120 125-130 208-215 220-240 380-415 440-480 A-NZM 7 (12V) A-NZM 7 (24V) A-NZM 7 (48V) A-NZM 7 (60V) A-NZM 7 (110-120V) A-NZM 7 (125-130V) A-NZM 7 (208-215V) A-NZM 7 (220-240V) A-NZM 7 (380-415V) A-NZM 7 (440-480V) See Price List See Price List Field installable and suitable for mounting into NZM 7 Circuit Breakers and Molded Case Switches. Note: The Early-Make feature of the contact is not effective when it is combined with the R-NZM 7 Remote Control Drive. Example: A-NZM 7 (110-120V) If ordering with device. Ordering information: Specify Type from column 3. For Immediate Delivery call KMParts. Example: + A-NZM 7 (110-120V) Auxiliary Contacts and Voltage Trips can be combined as follows: NHI 2 x EK. G G G G G VHI G — — — — A — G — — — AVHI — — G — — U — — — G — U(V)HI — — — — G Dots in each row represent the types which can be combined together. See Price List See Price List 3. Field installable.... The Shunt Trip and Early-Make contacts operate independently of one another.-NA 1 2 3 4 5 Rated Actuating Voltage (US) Type Price Notes $ See Price List See Price List See Price List L1(L+) 0 I H1 71 72 75 70 R-NZM 7 74 71 72 75 Remote Control Drive Operates the NZM 7 Circuit Breaker or Molded Case Switch electrically from a remote location. just specify a “+” in front of the Type number.. L2) 3-wire control 2-wire control L1(L+) 0 RHI H1 71 72 75 70 3-wire control with automatic reset to the OFF position after the circuitbreaker has tripped R-NZM 7 74 N(L-..14 Accessories are field installable.. AC/DC AC/DC DC DC L1(L+) 0 S H1 See Price List 110. OFF 100ms Local manual operation of the switch possible. The A.com at (866) 595-9616 See Price List 12 24 48 60 110-120 125-130 208-215 220-240 380-415 440-480 AVHI-NZM 7 (12V) AVHI-NZM 7 (24V) AVHI-NZM 7 (48V) AVHI-NZM 7 (60V) AVHI-NZM 7 (110-120V) AVHI-NZM 7 (125-130V) AVHI-NZM 7 (208-215V) AVHI-NZM 7 (220-240V) AVHI-NZM 7 (380-415V) AVHI-NZM 7 (440-480V) Field installable and suitable for mounting into NZM 7 Circuit Breakers and Molded Case Switches.. L2) See Price List Shunt Trips without Auxiliary Contacts C1 C2 AC/DC 1) See Price List Shunt Trips with Early-Make auxiliary contacts C1 C2 3.. 1) Maximum UL/CSA DC voltage is 125 VDC. Shunt Trips are rated for both AC and DC voltages and can accommodate a frequency range between 0 and 400 Hz. Shunt Trips cannot be mounted together with Undervoltage Trips. See Price List Shunt Trips 8 .120 220..Molded Case Circuit Breakers and Switches Remote Control Drive and Shunt Trips for Type NZM 7....240 24 48. Shunt Trips are rated for both AC and DC voltages and can accommodate a frequency range between 0 and 400 Hz.NZM 7 series is rated for 100% continuous duty.60 R-NZM 7 (110-120V) R-NZM 7 (220-240V) R-NZM 7 (24V) R-NZM 7 (48-60V) 70 R-NZM 7 74 N(L-. G G G G G RHI 1 x EK.. Molded Case Switches See Price List See Price List Shunt Trips are typically used to electrically trip the device from a remote location.. Switching Times: ON 100ms. com at (866) 595-9616 See Price List See Price List . They are rated for continuous duty.A Molded Case Circuit Breakers and Switches Undervoltage Trips for Type NZM 7... 8/48 For Immediate Delivery call KMParts. Example: U-NZM 7 (110-120V AC) If ordering with device. to disconnect the main switch in Emergency-Stop circuits.. Dashes indicate incompatibility.g.-N 1 2 3 4 Rated Actuating Voltage (US) Type suffix Price $ Undervoltage Trips Undelayed response Undervoltage Trips will electrically trip the device open under power loss (when supply voltage drops below 35 – 70% of rated trip coil value) and can be used for control interlocking purposes e. Ordering information: Specify Type from column 3. G G G G G AVHI — — G — — U — — — G — U(V)HI — — — — G Dots in each row represent the types which can be combined together.. Molded Case Switches DC 24 48 60 110 – 120 125 U-NZM 7 (24V DC) U-NZM 7 (48V DC) U-NZM 7 (60V DC) U-NZM 7 (110-120V DC) U-NZM 7 (125-130V DC) 8 Undervoltage Trips are field installable. Example: + U-NZM 7 (110-120V AC) Auxiliary Contacts and Voltage Trips can be combined as follows: NHI 2 x EK.. G G G G G RHI 1 x EK.. See Price List See Price List A — G — — — D1 U D2 AC 24 48 60 110 – 120 125 – 130 208 – 215 220 – 240 380 – 415 440 – 480 U-NZM 7 (24V AC) U-NZM 7 (48V AC) U-NZM 7 (60V AC) U-NZM 7 (110-120V AC) U-NZM 7 (125-130V AC) U-NZM 7 (208-215V AC) U-NZM 7 (220-240V AC) U-NZM 7 (380-415V AC) U-NZM 7 (440-480V AC) See Price List See Price List See Price List See Price List VHI G — — — — Undervoltage Trips without Auxiliary Contacts Circuit Breakers Disconnect Switches. just specify a “+” in front of the Type number. Undervoltage Trips cannot be mounted together with Shunt Trips. . Example: + UHI-NZM 7 (110-120V AC) Auxiliary Contacts and Voltage Trips can be combined as follows: NHI 2 x EK.com at (866) 595-9616 8/49 Circuit Breakers Disconnect Switches. Ordering information: Specify Type from column 3. For Immediate Delivery call KMParts.-NA 1 2 3 4 Rated Actuating Voltage (US) Type suffix Price $ Undervoltage Trips Undelayed response Undervoltage Trips will electrically trip the device open under power loss (when supply voltage drops below 35 – 70% of rated trip coil value) and can be used for control interlocking purposes e. They are rated for continuous duty. Example: UHI-NZM 7 (110-120V AC) If ordering with device.g. G G G G G RHI 1 x EK.Molded Case Circuit Breakers and Switches Undervoltage Trips for Type NZM 7. just specify a “+” in front of the Type number... G G G G G VHI G — — — — A — G — — — AVHI — — G — — U — — — G — U(V)HI — — — — G Dots in each row represent the types which can be combined together. to disconnect the main switch in Emergency-Stop circuits...13 AC U D2 3.. 1) Cannot be used in conjunction with R-NZM 7 Remote Control Drive. Undervoltage Trips cannot be mounted together with Shunt Trips. Molded Case Switches See Price List See Price List 24 48 60 110 – 120 125 – 130 208 – 215 220 – 240 380 – 415 440 – 480 UHI-NZM 7 (24V AC) UHI-NZM 7 (48V AC) UHI-NZM 7 (60V AC) UHI-NZM 7 (110-120V AC) UHI-NZM 7 (125-130V AC) UHI-NZM 7 (208-215V AC) UHI-NZM 7 (220-240V AC) UHI-NZM 7 (380-415V AC) UHI-NZM 7 (440-480V AC) See Price List See Price List See Price List 8 . See Price List Undervoltage Trips with Early-Make Auxiliary 1) D1 3.14 DC See Price List See Price List 24 48 60 110 – 120 125 UHI-NZM 7 (24V DC) UHI-NZM 7 (48V DC) UHI-NZM 7 (60V DC) UHI-NZM 7 (110-120V DC) UHI-NZM 7 (125-130V DC) Undervoltage Trips are field installable. Dashes indicate incompatibility. Example: H-NZM 7-NA If ordering with device.com at (866) 595-9616 See Price List See Price List Circuit Breakers Disconnect Switches. Hasp thickness 4 – 8 mm.+ (tripped) . Can be inscribed. Fastens to shaft. . Note: Rotary Drive Mechanism required. IEC IP 55 Door coupling rotary handle. Red-yellow For use as an Emergency-Stop Main Disconnect switch per IEC/EN 60204-1 (CE.. Rotary Drive Mechanism Converts ON and OFF switching from a toggle motion to a rotary motion Without padlocking feature DAOV-NZM 7 DA-NZM 7 See Price List See Price List See Price List 8 Black color (Standard) H-NZM 7-NA See Price List Black. RT-NZM 7 See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Insulating frame for door cutout (IP 40) Fastened from the back using screws. RH-NZM 7-NA Same features as the H-NZM 7-NA except that the padlocking feature is omitted. Door/cover interlocking supplied standard set in OFF position. Molded Case Switches With additional padlocking feature Rotary handle for open or panel mounted switches Black color. 8/50 For Immediate Delivery call KMParts. Handle position is fixed when door or cover is open. Machinery Directive) Handles can be locked in the OFF or ON position with up to 3 padlocks. For front mounting in doors and covers. just specify a “+” in front of the Type number.Molded Case Circuit Breakers and Switches Accessories for Type NZM 7. Hasp thickness 4 – 8 mm. See Price List See Price List Can be locked in the OFF position with up to 3 padlocks. without padlocking feature HOV-NZM 7-NA See Price List Extension shaft Can be cut to required length For mounting depths in the range of 175 – 400 mm For mounting depths in the range of 260 – 600 mm A400-NZM 7 A600-NZM 7 Ordering information Specify Type from column 3. Example: + H-NZM 7-NA. not padlockable HU-NZM 7 Handle for Cover/Door Interlocking Degree of protection UL/NEMA 12.. Rotary Drive Mechanism required.ON. 3 distinct Handle positions: 0FF .-NA 1 2 3 4 5 Type Price $ Notes Fits around the cutout area of the panel door through which the toggle mechanism on the front part of the switch protrudes. .. These kits provide the necessary accessories to fulfill the Main Disconnect switch function per the Machinery Directive standard IEC 60 204-1. insert the language code number into the type reference.. Example: External warning plate in French would be.. mechanism mounts directly on top of the DA(OV) Rotary Drive Mechanism. Color: Black for standard Main Disconnect function V-NZM 7-SW EA-NZM 7-L EA-NZM 7-R See Price List See Price List EA. Note: In cases where the Main Disconnect switch also fulfills the Emergency-Stop function.-NZM 7 See Price List See Price List External warning plates available in: 61 German 72 Portuguese 63 French 73 Romanian 64 Bulgarian 74 Russian 65 Danish 75 Swedish 66 Finnish 76 Serbo-Croatia 67 Dutch 77 Spanish 68 Italian 78 Czech 69 Greek 79 Turkish 70 Norwegian 80 Hungarian 71 Polish 81 Afrikaans To obtain warning plates in other languages. ZFS 63-NZM 7 Ordering information: Specify Type from column 3. An extension shaft (280 mm) with a special coupling piece is supplied with the unit.... just specify a “+” in front of the Type number. V-NZM 7 With black rotary handle For operation on the left For operation on the right With red-yellow rotary handle for use as Emergency-Stop devices to IEC/EN 60204-1 For operation on the left For operation on the right See Price List See Price List For side wall installation See Price List See Price List With door interlocking rotary handle. Molded Case Switches Main Disconnect Switch Assembly Kits for CE marked control panels per IEC/EN 60 204-1 (Machinery Directive) See Price List For mounting the switch directly into the side panel of the enclosure.. With door interlocking rotary handle. Example: + SWA-NZM 7.Molded Case Circuit Breakers and Switches Accessories for Type NZM 7.-NA 1 2 3 4 5 Type Price $ See Price List Notes Enables actuation of the switch from its left or right side as opposed to the front.. Color: Red-Yellow for Main Disconnect switches fulfilling the Emergency-Stop function.L For Immediate Delivery call KMParts. Kits contain: • Door interlocking rotary handle • DAOV rotary drive • Extension shaft for 400 mm mounting depth • External warning plate • Black lightning symbol See Price List See Price List 8 .. V.L If ordering with device. side wall operator equipped switches. For use only with SWA. Kits contain: • Door coupling rotary handle • DAOV rotary drive • Side wall operator with extension shaft • Mounting brackets • External warning plate • Black lightning symbol EA-RT-NZM 7-L EA-RT-NZM 7-R External warning plate English text Inscription: “Main Switch – Open only in OFF position” ZFS 62-NZM 7 See Price List See Price List Blank ZFS 60-NZM 7 Other Languages ZFS.com at (866) 595-9616 See Price List See Price List 8/51 Circuit Breakers Disconnect Switches. The SWA. For operation on the left For operation on the right SWA-NZM 7-L SWA-NZM 7-R Mounting bracket for side-panel mounting MSWA-NZM 7 See Price List See Price List See Price List See Price List Side wall operator The SWA shifts the rotary movement of the switch by 90˚ and permits the rotary handle to mount and actuate the switch from the side of the control panel enclosure. Example: SWA-NZM 7. please specify kits containing red handle and yellow backing plate assemblies... .-NA 1 2 3 4 5 Type Price $ See Price List Mechanical interlock KV 2-NZM 7 See Price List See Price List See Price List For interlocking two Type NZM 7. Example: + KV 2-NZM 7 8/52 For Immediate Delivery call KMParts.. Clip plate not suitable for switches equipped with R-NZM 7 Remote Control Drives. Example: KV 2-NZM 7 If ordering with device.. Molded Case Switches . Circuit Breakers or Molded Case Switches C-NZM 7 See Price List Clip plate For mounting two Type NZM 7... 8 Ordering information: Specify Type from column 3.Molded Case Circuit Breakers and Switches Accessories for Type NZM 7.com at (866) 595-9616 See Price List Circuit Breakers Disconnect Switches.. Circuit Breakers or Molded Case Switches onto a DIN rail conforming to EN 50 022. just specify a “+” in front of the Type number. top or bottom. Control Circuit Wire Range: AWG 14 – 18 Cu only. Ordering information: Specify Type from column 2 or 4. Recommended on the supply side of Circuit Breakers and Disconnect Switches. Fits over three terminals. Terminal Cover For additional protection against shock hazard. Example: + ST-250-NZM 7-U For Immediate Delivery call KMParts.com at (866) 595-9616 8/53 Circuit Breakers Disconnect Switches. +ST M8-NZM 7-O +ST M8-NZM 7-U See Price List See Price List See Price List See Price List 2 Terminals per set. Molded Case Switches See Price List See Price List See Price List See Price List 8 . Control Circuit Price Type Ordered separately Price Notes $ See Price List See Price List $ See Price List See Price List See Price List See Price List +ST 250-NZM 7-O +ST 250-NZM 7-U — — — — See Price List See Price List For Circuit Breakers and Molded Case Switches with bolt-on connection terminals..Molded Case Circuit Breakers and Switches Accessories for Type NZM 7.-NA 1 2 3 4 5 6 Type Ordered with device -O = Mounted on the top -U = Mounted on the bottom Control circuit Tap-off terminals Installed onto the upper and lower field-wiring terminals of Circuit Breakers and Molded Case Switches.. Finger proof to IEC 536 +KA 250-NZM 7 KA 250-NZM 7 One piece cover. . 600 VAC Type NZM 10.com at (866) 595-9616 .. Overview UL / CSA IEC/EN 60 947 / CE 4 3 3 4 1 5 Circuit Breakers Disconnect Switches.Molded Case Circuit Breakers and Switches. 600 Amps. Molded Case Switches 2 6 7 8 8 9 8/54 For Immediate Delivery call KMParts. 2 Auxiliary Contacts – Page 8/64 Type NHI. CSA certified (C 22. Lockable in the OFF position. 600 Amp rating Field installable accessories UL Listed (UL 1087). 600 Amps.. Molded Case Switches 8 . Early-Make auxiliary contact: For interlocking and load shedding purposes. To power up the undervoltage trip prior to main contact closing Voltage Trips: Shunt Trips AC & DC versions Undervoltage Trips AC & DC versions 9 Signalling Block – Page 8/64 Differentiated fault indication Overload early warning signal for load shedding purposes Local or remote signalling of breaker status Local.com at (866) 595-9616 8/55 Circuit Breakers Disconnect Switches. For Immediate Delivery call KMParts. standard auxiliary contact: For signalling ON and OFF positions Type RHI. CSA certified (C 22.. remote or automatic reset. Bolt-on connection for crimped lug or busbar.. 600 Amp rating Up to 100 kA @ 480 VAC Interrupting rating Standard and fuseless current limiting versions Solid State Trip Field installable accessories Supplied with terminals for cable hookup or bolt-on connection UL Listed (UL 489). Overview NZM 10 1 Molded Case Breaker – Page 8/58 – 60 600 VAC.. 4 Terminal Connections – Page 8/ Pressure wire terminations for cable connection. 600 VAC Type NZM 10.1) Conformity with IEC/EN 60 947-2 (Circuit Breakers) 5 Remote Control Drive – Page 8/67 Electrical operation of the circuit breaker from a remote location: Remote ON/OFF Remote Reset after Trip Local manual operation possible Padlockable OFF position 6 Rotary Handle – Page 8/68 To operate switch equipped with rotary drive mechanism. trip-indicating auxiliary contact: For signalling the Tripped (“+”) position 8 Ground Fault Trip Module – Page 8/67 Plugs directly into the breaker or mounts separately.2) Conformity with IEC/EN 60 947-3 (Switch-Disconnectors) 7 Rotary Drive Mechanism – Page 8/68 Converts toggle switch operation of the switch into a rotary movement suitable for rotary style operators..Molded Case Circuit Breakers and Switches. 3 Auxiliary Contacts & Voltage Trips – Page 8/64 – 66 Type VHI.. Terminal covers for additional protection against shock hazards. Automatic Reset.. Adjustable ground fault trip and time delay settings..2 # 5.2 # 5. Not fed from separate power source. 1 Molded Case Switch – Page 8/61 600 VAC. (N)(S)/ZM(V)(A).... Molded Case Switches Molded Case Switches NZM 10-....-NA — — — G G G G Circuit Breakers Disconnect Switches....H/ZM(A).Molded Case Circuit Breakers and Switches Type NZM 10...-NA 250 400 600 NHIRHIVHI-NZM 10 NZM 10 NZM 10 Not in conjunction with R-NZM 10 G G G MNZM 10 Molded Case Circuit Breakers NZM 10-...(N)(S)/ZM(V)(A)..: Early-Make) Signalling Block ZM(A)-...: Trip Indicating) (VHI.. Overview of Combination Options Type Solid State Trip Modules Solid State Trip Modules with pick-up delay for selectivity Auxiliary contacts (NHI.com at (866) 595-9616 .-NA or G NZM 10-....-NA 250 400 600 ZMV(A)-.....-NA +R-NZM 10 or G G — G 8 NZM 10-.N/B-NA +R-NZM 10 — — — — — — G G — G — — — G G — — Circuit Breaker Switch blocks without Trip Modules NZM 10-400N-NA NZM 10-400S-NA NZM 10-400H-NA NZM 10-600N-NA NZM 10-600S-NA NZM 10-600H-NA G Options for combination Included as standard G G G G G G G G G G G G — — — G G G G G — G G — G G — G G — — — — G G — G G G G G G G G G G G G G G G G G G With ZM(V) G G G G G G 8/56 For Immediate Delivery call KMParts...-NA + R-NZM 10 Molded Case Switches equipped with Remote Control Drive NZM 10-....N/B-NA — — — — — — G G G — Circuit Breakers equipped with Remote Control Drive NZM 10-..: Standard) (RHI...H/ZM(A). .Molded Case Circuit Breakers and Switches Type NZM 10...: Undervoltage Trip) Terminals Bolt connection included as standard ANZM 10 UNZM 10 TVNZM 10 RNZM 10 DNZM 10 H 10UNZM 10 (R)H 10NZM 10 Bolt-on connection Cable Terminals G or G G G or G G or G G or G G or G G G or G G or G G or G G or G — G or G G or G G or G G or G G — — — G or G G or G G — — — G or G G or G — — — — G or G G G G G G G or or or or or or G G G G G G G G G G G G or or or or or or G G G G G G or or or or or or G G G G G G G G G G G G or or or or or or G G G G G G G G G G G G or or or or or or G G G G G G For Immediate Delivery call KMParts.. Molded Case Switches 8 .. Overview of Combination Options Voltage Trips Ground-Fault Remote Rotary Drive Mechanism Trip Control Rotary Handle (A.: Shunt Trip) Drive Door coupling rotary handle (U..com at (866) 595-9616 8/57 Circuit Breakers Disconnect Switches. 5.NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection.. 600V AC Solid State Trip..2 Nr.-NA 1 2 3 4 5 UL/CSA.Consult pages 8/62 – 71 for additional accessories./ZMV-...Inverse Time Circuit Breakers. Solid State Trip Circuit Breakers with a fixed or adjustable Long Time Response and adjustable instantaneous pick-up range. Solid State Trip Circuit Breakers with a fixed or adjustable Long Time Response and adjustable instantaneous pick-up range..-NA 200 – 400 300 – 600 400 – 4800 600 – 7200 — — NZM 10-400 N/ZM-400-NA NZM 10-600 N/ZM-600-NA Fixed Long Time response settings for Type NZM 10-.. Type NZM 10-..-NA with Short-Time Delay pick-up for Selectivity 200 – 400 300 – 600 1000 – 9000 1000 – 9000 400 – 4800 600 – 7200 NZM 10-400 N/ZMV-400-NA NZM 10-600 N/ZMV-600-NA Type NZM 10-...-NA are UL Listed (UL 489) and CSA Certified (22. 5.. Consult page 8/68 for additional handle types....(N)(S)/ZMV(A)-. CE 6 Long Time Response Current Setting (Ir) Adjustable instantaneous Pick-up Setting Adjustable Short Time Delay Pick-up setting for selectivity in networks Time delay Range: 0 – 1000 ms Type (N) Normal Level Interrupting: Price 42 kA @ 480 VAC $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Amps Amps Amps Fixed Long Time response settings for Type NZM 10-.2 Nr.. N/ZMA-../ZMVA-.. Molded Case Switches Adjustable Long Time response settings for Type NZM 10-. Type NZM 10.(N)(S)/ZM(A)-. For Line and Load field-wiring terminals for cable connection.-NA 200 225 250 300 350 400 500 600 400 – 2400 450 – 2700 500 – 3000 600 – 3600 700 – 4200 800 – 4800 1000 – 6000 1200 – 7200 — — — – — — — — NZM 10-400 N/ZMA-200-NA NZM 10-400 N/ZMA-225-NA NZM 10-400 N/ZMA-250-NA NZM 10-400 N/ZMA-300-NA NZM 10-400 N/ZMA-350-NA NZM 10-400 N/ZMA-400-NA NZM 10-600 N/ZMA-500-NA NZM 10-600 N/ZMA-600-NA (600A) Circuit Breakers Disconnect Switches... IEC/EN 60 947-2. Type NZM 10-.NZM 10 Circuit Breakers and Molded Case Switches are supplied with toggle operator. Ordering Information: State type from Column 5..1) Inverse Time. Example: NZM 10-600 H/ZMA-500-NA.1) Current Limiting Inverse Time. 600 Amps. The time delay response is adjustable from 0 to 1000 milliseconds..com at (866) 595-9616 . 7 or 9.-NA with Short-Time Delay pick-up for Selectivity 200 225 250 300 350 400 500 600 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir NZM 10-400 N/ZMVA-200-NA NZM 10-400 N/ZMVA-225-NA NZM 10-400 N/ZMVA-250-NA NZM 10-400 N/ZMVA-300-NA NZM 10-400 N/ZMVA-350-NA NZM 10-400 N/ZMVA-400-NA NZM 10-600 N/ZMVA-500-NA NZM 10-600 N/ZMVA-600-NA 8 Adjustable Long Time response settings for Type NZM 10-... 5.1) and have an additional short time delay pick-up range for selectivity in energy distribution networks.H/ZM(A)-.-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22... Note: .. refer to page 8/70 – 71 for details on available terminals. .. N/ZM-..2 Nr....-NA Molded Case Circuit Breakers are UL Listed (UL 489) and CSA Certified (22. 8/58 For Immediate Delivery call KMParts. . .-NA 65 NZM 10-... IEC/EN 60 947-2.. Long time response current can be disconnected. 600 Amps.) for current levels at 6 x the long time response current (Ir). 600 VAC Solid State Trip..) or adjustable (ZMV.. Type NZM 10.com at (866) 595-9616 8/59 Circuit Breakers Disconnect Switches.. Adjustable time delay (0 – 1000 ms) pick-up setting..UL/CSA. NZM 10-.-NA 200 For Immediate Delivery call KMParts.) long time response current.. 60Hz) Type Features of ZMV(A)... Molded Case Switches NZM 10-400 S/ZMA-200-NA NZM 10-400 S/ZMA-225-NA NZM 10-400 S/ZMA-250-NA NZM 10-400 S/ZMA-300-NA NZM 10-400 S/ZMA-350-NA NZM 10-400 S/ZMA-400-NA NZM 10-600 S/ZMA-500-NA NZM 10-600 S/ZMA-600-NA NZM 10-400 H/ZMA-200-NA NZM 10-400 H/ZMA-225-NA NZM 10-400 H/ZMA-250-NA NZM 10-400 H/ZMA-300-NA NZM 10-400 H/ZMA-350-NA NZM 10-400 H/ZMA-400-NA NZM 10-600 H/ZMA-500-NA NZM 10-600 H/ZMA-600-NA 4 See Price List See Price List See Price List See Price List 2 See Price List See Price List See Price List See Price List 8 . Adjustable time delay (2 – 20 sec.. H/ ZM(A)-. 66 8/69 8/71 NZM 10-400 S/ZMV-400-NA NZM 10-600 S/ZMV-600-NA See Price List See Price List — — See Price List See Price List UL/CSA Interrupting ratings (AC...... N/ ZM(V)(A)-.-NA 100 NZM 10-.-NA 10 11 Type (S) Super Level Interrupting: Price Type (H) Highest Level Interrupting: Fuseless Current Limiting Circuit Breaker 100 kA @ 480 VAC Price 65 kA @ 480 VAC $ See Price List See Price List $ See Price List See Price List NZM 10-400 S/ZM-400-NA NZM 10-600 S/ZM-600-NA NZM 10-400 H/ZM-400-NA NZM 10-600 H/ZM-600-NA 1 See Price List See Price List See Price List See Price List 3 3 3 NZM 10-400 S/ZMVA-200-NA NZM 10-400 S/ZMVA-225-NA NZM 10-400 S/ZMVA-250-NA NZM 10-400 S/ZMVA-300-NA NZM 10-400 S/ZMVA-350-NA NZM 10-400 S/ZMVA-400-NA NZM 10-600 S/ZMVA-500-NA NZM 10-600 S/ZMVA-600-NA — — — — — — — — See Price List See Price List See Price List See Price List Accessories 1 2 3 4 Auxiliary contacts Voltage Trips Handles and operators Terminals Page 8/64 8/65.. S/ ZM(V)(A)-... Adjustable instantaneous pick-up response.Trip Modules used for Selectivity: RMS Sym kAmps @ 240 V 480 V 42 65 100 600 V 35 42 50 Fixed (ZMVA. CE 7 8 9 Inverse Time Circuit Breakers. 8/60 For Immediate Delivery call KMParts. UL/CSA (N) Normal Level Short circuit Rating $ Circuit Breakers Disconnect Switches.-CNA 1 2 3 4 5 Frame Rating Continuous Current Rating Adjustable Instantaneous Trip Response Range Amps Type Price See Price List See Price List See Price List See Price List See Price List See Price List 400 800..N/ZM-.H Instantaneous Trip Circuit Breakers.Consult page 8/67 for additional accessories... Short circuit interrupting ratings are. UL/CSA (H) High Level Short circuit Rating 400 800.4800 NZM 10-400 N/ZM -400-OBI-CNA 600 1200..4800 NZM 10-400 H/ZM -400-OBI-CNA 600 1200. established and valid only for the listed combination motor controller assembly and associated housing or enclosure.Instantaneous Trip type... Molded Case Switches .... they provide motor short circuit protection as part of a listed combination motor controller that includes coordinated motor overload protection.. refer to page 8/71 for details on available terminals.-CNA Molded Case Circuit Breakers are UL Recognized (UL 489) and CSA Certified (22../ZM-.....com at (866) 595-9616 See Price List See Price List See Price List See Price List See Price List See Price List Amps Solid State Instantaneous Trip Circuit Breakers 600 V AC. Example: NZM 10-600 H/ZM-600-OBI-CNA Note: .2 Nr.... Per NEC.NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection..-OBI.NZM 10 Circuit Breakers and Molded Case Switches are supplied with toggle operator. 600 Amp NZM 10-.N/ZM-......-OBI-CNA (600 Amps) Solid State Instantaneous Trip Circuit Breakers 600 V AC. 5.-OBI..1) Instantaneous Trip type Circuit Breakers with an adjustable instantaneous trip function. Ordering Information: State type from Column 4....H/ZM-....H instantaneous trip circuit breaker features a current limiting design contact assembly and can provide high fault short circuit current ratings for motor starters of up to 65kA @ 480VAC.. .....-OBI. Consult page 8/69 for additional handle types. .-OBI-CNA (600 Amps) 8 Type NZM10-.7200 NZM 10-600 H/ZM -600-OBI-CNA NZM 10-. therefore.-CNA and NZM10-. The NZM 10.. Consult Moeller Electric for Combination Motor Controller high fault short circuit ratings as Motor Control Center unit starters featuring Type NZM10..N/ZM-..Molded Case Circuit Breakers .N and NZM10..7200 NZM 10-600 N/ZM -600-OBI-CNA NZM 10-. For Line and Load field-wiring terminals for cable connection. IEC/EN 60 947-3. Consult page 8/69 for additional handle types. Ordering Information: Specify Type from Column 3.UL/CSA..-NA 4 5 Ampere Rating Type Price Notes Amps $ See Price List See Price List See Price List See Price List Molded Case Switches With provisions for bolt-on connection 400 NZM 10-400 N/B-NA See Price List UL/CSA Short Circuit Current Rating: 25 kA RMS Sym @ 600 VAC 600 NZM 10-600 N/B-NA See Price List Type NZM 10-.. auxiliary contacts. For Immediate Delivery call KMParts.N/B-NA Molded Case Switches are virtually identical in construction to NZM 10 Molded Case Circuit Breakers except that they are manual. Note: . refer to page 8/71 for details on available terminals.2). Accessories such as voltage trips.2 Nr. . 5.. Molded Case Switches are tested to determine their acceptability for continuous operation at their marked rated load. are common to all NZM 10 circuit breakers and molded case switches and are UL listed and CSA certified for field installation. 600 Amps.NZM 10 Circuit Breakers and Molded Case Switches are supplied with toggle operator. they are tested at six times their full ampere rating to cover motor circuit applications and are suitable for use as motor circuit disconnects per Section 430-109 of the National Electrical Code.Consult page 8/67 for additional accessories. They are equally rated up to 600 Amps.com at (866) 595-9616 8/61 Circuit Breakers Disconnect Switches. In addition. 600 VAC Type NZM 10. rotary handles etc. Molded Case Switches See Price List See Price List See Price List See Price List 8 . Example: NZM 10-400 N/B-NA. CE 1 2 3 Molded Case Switches. For Line and Load field-wiring terminals for cable connection. .. non-automatic switches without any overload or overcurrent protective features. All Molded Case Switches are UL Listed (UL 1087)/ CSA certified (C 22.NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. in conformity with IEC/EN 60 947-3 (Switch-Disconnectors) and CE marked. Molded Case Switches 200 225 250 300 350 400 500 600 200 – 400 300 – 600 400 – 2400 450 – 2700 500 – 3000 600 – 3600 700 – 4200 800 – 4800 1000 – 6000 1200 – 7200 400 – 4800 600 – 7200 — — — — — — — — — — G G G G G G — — G — G G G G G G G G G G Adjustable Long Time Response 8 Solid State Trip Modules for Selectivity in networks Fixed Long Time Response 200 225 250 300 350 400 500 600 200... Solid State Trip Modules 1 2 3 4 5 UL/CSA.9000 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 2 – 12 x Ir 400. NZM10-600. 8/58.-NA RMS Sym kA @ 240 V 480 V 600 V 65 100 200 42 65 100 35 42 50 Type NZM 10. NZM10-400...-NA NZM 10-. or assembled from components by combining Switch Blocks and protective Trip Modules.. Amps Switch Blocks... Dashes ( — )indicate incompatibility.Inverse Time Circuit Breaker Components.-NA NZM 10-... S/ ZM(V)(A)-.400 300..... Example: NZM10-600N-NA (Switch Block) +ZMA-500-NZM 10-NA (Trip Module) = NZM 10-600 N/ZMA-500-NA Molded Case Circuit Breaker 8/62 For Immediate Delivery call KMParts... 600 Amps... Refer to chart at bottom of page for resultant interrupting ratings.. 600VAC Type NZM 10. Switch Block Ratings Continuous Current (Iu) Trip Module Ratings Long Time Response Current Setting (Ir) Adjustable instantaneous Pick-up Setting Adjustable Short Time Delay Pick-up setting for selectivity in networks Time delay range: 0 – 1000 ms Compatibility of Switch Block with Trip Module Dots (G) in each row indicate which Trip Module (Refer to column 7) can be used with the Switch Block type shown below..-NA Switch Blocks..59).... Switch Blocks and Trip Modules can be ordered separately and combined per the charts and columns shown here to suit any particular application. N/ ZM(V)(A)-.. Molded Case Circuit Breakers can be ordered complete (consult p.... 60Hz) Type NZM 10-. CE 6 The NZM 10 Inverse Time Molded Case Breaker is made up of a Switch Block and a protective Trip Module.9000 1000. IEC/EN 60 947-2...600 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000 – 9000 1000. Suitable for insertion of Trip Modules 400 400 400 600 600 600 Solid State Trip Modules Fixed Long Time Response Amps Amps Amps Circuit Breakers Disconnect Switches. H/ ZM(A)-.4800 600.7200 G G G G G G — — G — G G G G G G G G G G Adjustable Long Time Response UL/CSA Interrupting ratings (AC..com at (866) 595-9616 ... and ZMV Trip Modules cannot be combined with NZM 10-400 H-NA and NZM 10-600 H-NA Switch Blocks. Add a Trip Module from below to complete the breaker assembly...UL/CSA..-NA Switch Blocks. 2 8 . 3 3 3 Accessories ZM solid state trip modules have an adjustable long time response and an adjustable instantaneous pick-up range. Refer to Column 6 for compatibility information on Switch Blocks and Trip Modules.com at (866) 595-9616 See Price List 8/63 Circuit Breakers Disconnect Switches. Adjustable instantaneous pick-up response. Consult page 8/69 for additional handle types. Adjustable time delay (2 – 20 sec. refer to page 8/71 for details on available terminals.NZM 10 Switch Blocks are supplied with toggle operator.. CE 7 8 9 Inverse Time Circuit Breaker Components. Example: NZM 10-600 N-NA Note: . . Note: ZMVA. Long time response current can be disconnected. 600 Amps. Molded Case Switches NZM 10-400N-NA NZM 10-400S-NA NZM 10-400H-NA NZM 10-600N-NA NZM 10-600S-NA NZM 10-600H-NA NZM 10 Switch Blocks make up a complete breaker minus the protective Trip Module. Solid State Trip Modules 10 Type Price Notes $ See Price List See Price List 4 See Price List See Price List 1 See Price List See Price List ZMA-200-NZM 10-NA ZMA-225-NZM 10-NA ZMA-250-NZM 10-NA ZMA-300-NZM 10-NA ZMA-350-NZM 10-NA ZMA-400-NZM 10-NA ZMA-500-NZM 10-NA ZMA-600-NZM 10-NA ZM-400-NZM 10-NA ZM-600-NZM 10-NA See Price List See Price List ZMA solid state trip modules have a fixed long time response and an adjustable instantaneous pick-up range..Compatible Trip Modules will easily fit into the front part of the switch block. 66 8/69 8/71 See Price List See Price List See Price List See Price List ZMVA-200-NZM 10-NA ZMVA-225-NZM 10-NA ZMVA-250-NZM 10-NA ZMVA-300-NZM 10-NA ZMVA-350-NZM 10-NA ZMVA-400-NZM 10-NA ZMVA-500-NZM 10-NA ZMVA-600-NZM 10-NA ZMV-400-NZM 10-NA ZMV-600-NZM 10-NA Features of ZMV(A).Consult page 8/67 for additional accessories..) for current levels at 6 x the long time response current (Ir).) long time response current. For Line and Load field-wiring terminals for cable connection.. IEC/EN 60 947-2. Adjustable time delay (0 – 1000 ms) pick-up setting. Incompatible Trip Modules and Switch Block combinations are mechanically blocked to prevent creation of improper combinations.. . Trip Modules used for Selectivity: Fixed (ZMVA. 1 2 3 4 Auxiliary contacts Voltage Trips Handles and operators Terminals Page 8/64 8/65.. (Refer to columns 6 & 7) . Refer to chart at bottom of opposite page for resultant circuit breaker interrupting ratings.. 600VAC Type NZM 10.) or adjustable (ZMV.NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. For Immediate Delivery call KMParts. See Price List Ordering Information: Specify Type from column 7. C. (2) Tripping due to overload and general trip condition.32 Signalling Block Differential fault indication and visual display of breaker operating states (1) Tripping due to short-circuit.43 4.14 5.32 VHI Early-Make auxiliary contacts Typically used for powering up the undervoltage trip prior to closing of main contacts and for control circuit interlocking tasks.62 5.43 1.54 5.e.O.21 VHI-NZM 10 3.44 4.22 RHI trip-indicating auxiliary contacts Actuating independently of the normal ON and OFF operations of the device.13 3. & 1 N.44 1.42 5. just specify a “+” in front of the Type number. AC or DC (1) N.61 5.) Mounts directly onto lower portion of circuit-breaker Supply voltage necessary: 24 – 230 V.C.31 NHI-NZM 10 1.13 4. Cannot be used in conjunction with R-NZM 10 Remote Control Drive 3.13 5. N.com at (866) 595-9616 See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Auxiliary Contacts Circuit Breakers Disconnect Switches. N. 8 5.14 1.21 4.C. Molded Case Switches } } } . 1.53 5.34 5..33 5.Molded Case Circuit Breakers and Switches Auxiliary Contacts.14 3.13 1. switching only when the device has tripped due to overcurrents or other tripping causes such as those initiated by voltage trips.14 4.-NA 1 2 3 4 Contact sequence Type Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List NHI standard auxiliary contacts Switching simultaneously with the main contacts.22 4. (3) Overload early warning signal in the event that the long time response setting is about to be exceeded (i. (2) N. (3) N.O.41 5. They can be typically used for signalling. Ordering information: Specify Type from column 3. Signalling Unit for Type NZM 10.O. useful for load shedding purposes) Each function signals via a pair of contacts (1 N. Example: NHI-NZM 10 If ordering with device. N.21 5.33 3.31 RHI-NZM 10 4.22 ≥ 100 % Ir M-NZM 10 I> Auxiliary Contacts and Signalling Blocks are field installable. 4.21 1.22 1.. interlocking or switching auxiliary circuits such as a control circuit. Example: + NHI-NZM 10 8/64 For Immediate Delivery call KMParts.O.C.34 3. Ordering information: Specify Type from column 3. Shunt trips are field installable.NZM 10 series is rated for 100% continuous duty. C1 AC/DC 24 C2 A-NZM 10 (24V) A-NZM 10 (48V) A-NZM 10 (60V) A-NZM 10 (110-120V) A-NZM 10 (125-130V) A-NZM 10 (208-215V) A-NZM 10 (220-240V) A-NZM 10 (380-415V) A-NZM 10 (440-480V) A-NZM 10 (500V) A-NZM 10 (600V) See Price List 48 60 110 – 120 125 – 130 208 – 215 220 – 240 380 – 415 440 – 480 500 600 See Price List Field installable and suitable for mounting into NZM 10 Molded Case Circuit Breakers and Switches. Shunt Trips are rated for both AC and DC voltages and can accommodate a frequency range between 0 and 400 Hz. Example: + A-NZM 10 (110-120V) For Immediate Delivery call KMParts... Molded Case Switches See Price List See Price List See Price List See Price List 8 .-NA 1 2 3 4 5 Rated Actuating Voltage (US) Type Price $ each See Price List See Price List See Price List See Price List Shunt Trips Shunt Trips are typically used to electrically trip the device from a remote location.. Example: A-NZM 10 (110-120V) If ordering with device. Shunt Trips cannot be mounted together with Undervoltage Trips.. just specify a “+” in front of the Type number..com at (866) 595-9616 8/65 Circuit Breakers Disconnect Switches.Molded Case Circuit Breakers and Switches Shunt Trips for Type NZM 10. The A. com at (866) 595-9616 See Price List TV-NZM 10/E See Price List See Price List No outside power source necessary.21 I∆n 6. They are rated for continuous duty. 160. 360. 1000 ms See Price List See Price List 24 48 60 110 – 120 125 – 130 208 – 215 220 – 240 U-NZM 10 (24V DC) U-NZM 10 (48V DC) U-NZM 10 (60V DC) U-NZM 10 (110-120V DC) U-NZM 10 (125-130V DC) U-NZM 10 (208-215V DC) U-NZM 10 (220-240V DC) See Price List See Price List 24 48 60 110 – 120 125 – 130 208 – 215 220 – 240 380 – 415 440 – 480 500 600 U-NZM 10 (24V AC) U-NZM 10 (48V AC) U-NZM 10 (60V AC) U-NZM 10 (110-120V AC) U-NZM 10 (125-130V AC) U-NZM 10 (208-215V AC) U-NZM 10 (220-240V AC) U-NZM 10 (380-415V AC) U-NZM 10 (440-480V AC) U-NZM 10 (500V AC) U-NZM 10 (600V AC) See Price List See Price List See Price List See Price List See Price List Circuit Breakers Disconnect Switches. 150. to disconnect the main switch in Emergency-Stop circuits. 320. 60.22 TV-NZM 10 Accessories are field installable. Undervoltage Trips cannot be mounted together with Shunt Trips.Molded Case Circuit Breakers and Switches Undervoltage Trips and Ground Fault Trip Module for Type NZM 10. D1 U D2 See Price List AC DC See Price List See Price List See Price List See Price List See Price List Ground Fault Trip Module Attached directly to the breaker or mounted separately 8 6.130.13 – 6. Example: + U-NZM 10 (110-120V) 8/66 For Immediate Delivery call KMParts. 750. Example: U-NZM 10 (110-120V) If ordering with device. Ordering information: Specify Type from column 3.g. 100.14 6.-NA 1 2 3 4 Rated Actuating Voltage (US) Type Price $ Undervoltage Trips Undelayed response Undervoltage Trips will electrically trip the device open under power loss (when supply voltage drops below 35 – 70% of rated trip coil value) and can be used for control interlocking purposes e.. Ground Fault Trip Module is mounted separately: Ground fault trip current is signalled directly to a shunt or undervoltage trip via auxiliary contacts 6.. just specify a “+” in front of the Type number. 200. 500. 300. 240. Molded Case Switches . ground fault trip current adjustable in steps: I∆n = 80. 400 A With an adjustable delay time: tv = 0.14 or 6. 280.13 6. 200.22 Ground Fault Trip Module is attached to the circuit-breaker: Ground fault trip current is signalled directly to the breaker electronic circuitry.21 – 6. Electrical switching from a remote location and manual tripping of the circuit breaker (push to trip feature) are not affected. Not for use in conjunction with KVR2-NZM 10 mechanical interlock.-NA Molded Case Circuit Breakers and Switches Remote Control Drives and Accessories 1 2 3 4 5 Contact diagram Rated Actuating Voltage (US) 50/60 Hz Type Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Remote Control Drive For both Circuit Breakers and Molded Case Switches Switching times: ON 60 ms.. L2) N(L-. L2) 3-wire control 2-wire control 100 – 130 DC R-NZM 10 (100-130V DC) 220 – 240 DC R-NZM 10 (220-240V DC) Pushbutton operator For manual ON-OFF switching of encapsulated NZM 10 breakers and switches equipped with a remote control drive. just specify a “+” in front of the Type number. Example: + R-NZM 10 (110-120V AC) For Immediate Delivery call KMParts. RTR-NZM 10 Sealing plate To block off manual switching access of the remote control drive at the device.Type NZM 10. Molded Case Switches Mounts on top of NZM 10 Circuit Breakers and Molded Case Switches 3-wire control with automatic reset to the OFF position after the switch has tripped. Mounting depth 250 – 285 mm ` Mounting depth 285 – 400 mm MD-NZM 10 MDV-NZM 10 IP 54 Protective cover for door cutout area Transparent cover to provide a panel cutout area with IP 54 protection For use where the Remote Control Drive protrudes from the cutout area of the enclosure door.. L2) N(L-. PL-NZM 10 Ordering information: Specify Type from column 4. 8 . OFF 30 ms Manual switching possible L1(L+) 0 I H1 71 72 75 L1(L+) 0 S H1 70 71 72 75 L1(L+) 0 RHI 110 – 120 AC R-NZM 10 (110-120V AC) H1 71 72 75 220 – 240 AC R-NZM 10 (220-240V AC) 380 – 415 AC R-NZM 10 (380-415V AC) 24 48 – 60 DC R-NZM 10 (24V DC) DC R-NZM 10 (48-60V DC) 70 70 R-NZM 10 74 R-NZM 10 74 R-NZM 10 74 N(L-. Example: R-NZM 10 (110-120V AC) If ordering with device.com at (866) 595-9616 8/67 Circuit Breakers Disconnect Switches. Requires Rotary Drive mechanism.com at (866) 595-9616 . Rotary Drive Mechanism D-NZM 10 Circuit Breakers Disconnect Switches..Molded Case Circuit Breakers and Switches Accessories for Type NZM 10. Required for the use of rotary and door coupling/interlocking rotary handles. Extension shaft For mounting depths 175 – 400 mm For mounting depths 260 – 600 mm A-NZM 10 A600-NZM 10 8 Maintenance Handle Can be cut to required length. Rotary Handle.-NA 1 2 3 4 Type Price Notes $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Toggle switch interlock SVB-NZM 10 See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Insulating cutout frame RT-NZM 10 Permits the OFF position of the toggle operator to be locked with up to 3 padlocks (hasp thickness 6 – 8 mm) For use where the toggle switch protrudes from the enclosure. No door interlocking or padlocking provisions. for open or panel mounted devices H10U-SW Black color. just specify a “+” in front of the Type number. Provides degree of protection IP 40. For Type A-NZM 10 Extension shafts For Type A600-NZM 10 Extension shafts H10UZ H12UZ For panel mounted switches Push-fits onto the extension shaft Ordering information: Specify Type from column 2. Can be locked in the OFF position with up to 3 padlocks. Can be inscribed. Example: + D-NZM 10 8/68 For Immediate Delivery call KMParts. Hasp thickness. Example: D-NZM 10 If ordering with device. Suitable for open mount switches. Molded Case Switches Converts ON and OFF switching from a vertical toggle movement to a rotary motion.. Affixed from the rear with screws. 4 – 8 mm. To actuate the device when the panel door is open. They are suitable for use as Main Disconnect Switches in control panels that must be CE marked and designed to comply with the Machinery Directive standard EN 60 204-1. but with red-yellow door interlocking rotary handle.-NZM 10 Blank plate (for engraving or printing) Ordering information: Specify Type from column 3.. tripped or ON) when panel door is open. just specify a “+” in front of the Type number. Example: H 10-SW-NA If ordering with device.com at (866) 595-9616 8/69 Circuit Breakers Disconnect Switches.ON Black color: For standard Main Disconnect Switch applications H 10-SW-NA See Price List See List Price See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Handle for Cover/Door Interlocking Red-yellow color: Enables the switch to be used as the Emergency-Stop Disconnect RH 10-NA Switch position indicator Indicates position of switch (OFF. IEC IP 55 With cover interlocking and padlocking feature Rotary Drive Mechanism required. Molded Case Switches 8 . color Black • Rotary Drive Mechanism • Extension shaft for 400 mm mounting depth • External warning plate • Black lightning symbol Same as above..-NA breakers and switches have dual UL/CSA and IEC/EN ratings. For use when Main Disconnect also fulfills Emergency-Stop function per IEC/EN 60204-1 Main Disconnect Warning plates English Inscription: “Main Switch – Open only in OFF position” Warning plates also available in other languages: 61 German 63 French 64 Bulgarian 65 Danish 66 Finnish 67 Dutch 68 Italian 69 Greek 70 Norwegian 71 Polish 72 Portuguese 77 Spanish 73 Romanian 78 Czech 74 Russian 79 Turkish 75 Swedish 80 Hungarian 76 Serbo-Croatia 81 Afrikaans V-NZM 10-SW V-NZM 10 ZS 62-NZM 10 To obtain warning plates in other languages.. Example: + H 10-SW-NA ZS 60-NZM 10 For Immediate Delivery call KMParts. Example: External warning plate in Spanish would be: ZS 77-NZM 10 ZS..-NA Accessories 1 2 3 4 Type Price $ Degree of protection UL/NEMA 3R/12. insert the language code number into the type reference. Can be locked in the OFF or ON position with up to 3 padlocks 3 distinct Handle positions: OFF. SA-NZM 10 Main Disconnect Switch Assembly Kits for CE marked control panels per IEC/EN 60 204-1 Type NZM 10-.Molded Case Circuit Breakers and Switches Type NZM 10.. Kit includes: • Door interlocking rotary handle.+(tripped). . Fits toggle operators or rotary drive mechanisms. Molded Case Switches .-NA 1 2 3 4 Type Price $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List For mechanically interlocking two NZM 10 Circuit Breakers or Molded Case Switches mounted in a panel. Fits toggle operators or rotary drive mechanisms For two circuit breakers For two circuit-breakers equipped with R-NZM 10 Remote Control Drives. Fits toggle operators or rotary drive mechanisms KV3-NZM 10 Possible switching positions: Incomer 1 0 1 Emergency 0 V V V 1 Incomer 2 0 0 1 1 V KVA3-NZM 10 0 V 0 = OFF V = Interlocked 1 = ON Ordering information: Specify Type from column 3.com at (866) 595-9616 See Price List See Price List 8 1 See Price List See List Price For emergency power supplies: Mechanically interlocking two incoming supply circuit breakers with one emergency supply breaker. (R-NZM 10 must be electrically interlocked at the same time) KV2-NZM 10 KVR2-NZM 10 For mechanically interlocking three NZM 10 Circuit Breakers or Molded Case Switches mounted in a panel. Example: KV2-NZM 10 8/70 For Immediate Delivery call KMParts.. See Price List See Price List See Price List See Price List Mechanical interlocks Circuit Breakers Disconnect Switches.Molded Case Circuit Breakers and Switches Accessories for Type NZM 10. Example: + K2 x 240IP-NZM 10-O 1) When ordering with the device (Column 4). the Type suffix specifies which side should be equipped with terminals: Suffix O . Not supplied with terminal cover..Qty. Suitable terminal cover is Type HH-NZM 10 Double cable clamp terminal. of one K2x240IP terminal. Molded Case Switches 8 . For Line and Load field-wiring terminals for cable connection. +H-NZM 10-O +H-NZM 10-U H-NZM 10 +HH-NZM 10-O +HH-NZM 10-U HH-NZM 10 NZM 10 Circuit Breakers and Molded Case Switches are supplied standard with bolt-on connection. Ordering information: Specify Type from Columns 4 or 6. are UL listed and CSA certified for reverse feed connection and can therefore be fed optionally from top or bottom. 3 pole terminal cover.com at (866) 595-9616 8/71 Circuit Breakers Disconnect Switches.Denotes a set of three terminals and covers mounted on the bottom. 2) Complete set of three (for top or bottom) Type K2x240(IP) terminals for field installation (column 6) consists of the following: .Molded Case Circuit Breakers and Switches Terminals for Type NZM 10.-NA 1 2 3 4 1) 5 6 7 General info Maximum Rated Current Amps Conductor Cross-section Range and Material Type suffix Price Sets of three terminals ordered with breaker or molded case switch: O = Mounted on Top U = Mounted on Bottom $ See Price List See Price List See Price List See Price List See Price List See List Price See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List Type Price Individual terminals supplied separately for field mounting $ See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See Price List See List Price See Price List See Price List Terminals Supplied with 3 terminal covers (Type H-NZM 10) and an insulating plate onto which the circuit breaker is mounted. Supplied with 1 terminal cover (Type H-NZM 10) and an insulating plate onto which the circuit breaker is mounted. Supplied standard with Type K2x240(IP) terminals. One piece. Supplied with 1 terminal cover (Type H-NZM 10) 600 2 x AWG 2 – 500 kcmil Cu/Al + K2X240IP-NZM 10-O + K2X240IP-NZM 10-U — — 600 2 x AWG 2 – 500 kcmil Cu/Al — K2X240IP-NZM 102) 600 2 x AWG 2 – 500 kcmil Cu/Al — K2X240-NZM 102) Single cable clamp terminal.Qty. which is supplied with one H-NZM 10 terminal cover and one insulating plate. Not supplied with cover.. . Note: All Moeller Electric Molded Case Circuit Breakers. which are supplied each with one H-NZM 10 terminal cover. Suitable for use with Type K300 or K2x120 terminals. select from information specified above.Denotes a set of three terminals and covers mounted on the top. All terminals can be ordered factory installed with the device (Column 4) or separately for field installation (Column 6). Suitable terminal cover is Type HH-NZM 10 350 250 – 500 kcmil Cu only + K300-NZM 10-O + K300-NZM 10-U K300-NZM 10 500 2 x AWG 3/0 – 250 kcmil Cu only +K2x120-NZM 10-O +K2x120-NZM 10-U K2x120-NZM 10 Terminal Covers Single pole terminal cover. Suffix U . of two K2x240 terminals. including the NZM 10. For Immediate Delivery call KMParts. Can be used for bolt-on or cable lug connection. -No...com at (866) 595-9616 . 2h 100 40 Tripping time Minutes 16 25 40 63 80 100 A Setting current NZMH 4-.....-No.1000 ms 800 1000 1250 400 100 1260 1600 3200 2500 2. 4. Ser./ZM 12 V-.. 9.. Minutes Tripping time 2h 100 40 10 4 1 40 Seconds 160 250 63 100 200 315 A Setting current NZM(H) 9-./ZM 6-. 12 Tripping Characteristics Tripping characteristics The tripping characteristics show the tripping time of the breakers in relation to the response current. 02 t r On 630 25000 12600 16000 20000 1 400 100 40 10 4 Minimum command time 1 100 200 400 1000 2000 4000 10000 20000 50000 A rms 2.. Ser... starting from cold... The tripping time of overload releases at operational temperature reduces to approximately 1/4 of that shown.. NZM..12 x I r 15000 7560 19200 9600 12000 25000 8/72 For Immediate Delivery call KMParts. 02 2h 100 40 10 4 1 40 10 4 400 630 1000 1600 315 500 800 1250 A Setting current NZM 12-.. Minutes Seconds Tripping time 10 4 1 40 10 4 1 400 100 100 10 4 1 160 190 260 400 475 600 1000 760 1150 1900 2400 320 260 500 400 600 800 1200 1000 2000 2400 4000 300 400 100 40 10 4 1 40 100 1500 1600 8 Minimum command time 200 400 1000 2000 4000 10000 20000 A rms 2h 100 40 400 630 1000 1600 315 500 800 1250 A Setting current NZM 12-.. 10 4 1 40 Seconds 10 4 1 400 100 320 200 500 800 1000 Milliseconds 100 40 10 4 1 6 10 20 40 100 Minimum command time 200 400 1000 2000 3000 A rms Milliseconds 40 10 4 1 20 40 100 200 Minimum command time 400 1000 2000 4000 10000 A rms Milliseconds Minutes Tripping time Tripping time 10 4 1 40 t r Ein Minutes Seconds 10 4 1 2000 Seconds Milliseconds 40 10 4 Minimum command time 1 100 200 400 1000 2000 4000 10000 20000 500000 A rms Milliseconds Circuit Breakers Disconnect Switches.. 6.20 x I u Delay time tv 10 ms.. Molded Case Switches 2h 100 40 25 40 125 200 63 100 160 A Setting current NZM(H) 6(B)-./ZM 12-.... The mean values of the tolerance bands are indicated at an ambient temperature of 20˚C../ZM 9-....Circuit-Breakers. .5 10 8 6 4 3 2 1.5 Breaking Capacity fw ave irst 175 A 100 A hal 250 A 250 A 200 A 175 A 100 A Ue = 480 V 60 Hz 4 3 2 1./ZM 6.5 2 3 4 6 8 10 15 20 30 40 60 80 100 Icc [kArms] 6A 10 A 40 A 16/25 A NZMH 4-.5 2 3 4 6 8 10 15 20 30 40 60 80 100 Icc [kArms] 1 hal fw ave 100 A 60 A 40 A √2 I cc 100 A 60 A 4 3 2 1...5 10 2 ƒi dt 10 7 2 [A s] 8 6 2 NZMH 6-...5 10 5 1 st hal 4 3 fw a ve 63/80/100 A 40 A 16/25 A 8 6 4 3 2 1..../ZM 9.5 1 1 1.5 10 6 8 6 4 3 2 1.5 10 6 8 6 125 A 160 A irst 8 6 4 3 2 1..5 2 Ue = 480 V 60 Hz Breaking Capacity 10 5 8 6 3 4 6 8 10 15 20 30 40 60 80 100 Icc [kArms] ÎD [kA] 8 NZMH 9-. 6. 9 Let-Through Characteristics Let-through current ÎD ÎD [kA] 100 80 60 40 30 63/80/100 A 20 15 10 8 6 4 3 2 1. 6 2 1. Let-through energy I2t ƒi dt 2 [A s] 2../ZM 9..Circuit-Breakers NZMH 4. 6 4 3 2 1.com at (866) 595-9616 Breaking Capacity 10 6 8 6 i2 tf 8/73 Circuit Breakers Disconnect Switches.5 1 1 1.5 10 1 8 6 4 3 2 1.5 1 Ue =380/415 V 1 1.5 2 3 4 6 8 10 15 20 30 40 60 80 100 Icc [kArms] √2 I cc ƒi dt 10 8 2 [A s] 8 6 2 NZMH 9-.5 10 2 8 6 4 3 2 1. 4 3 2 1.5 2 3 4 6 10 A 6A Ue = 380/415 V 8 10 15 20 30 40 60 80 100 ÎD [kA] 8 NZMH 6-. Molded Case Switches Icc [kArms] i2 tf 8 .5 10 4 1 1.5 10 4 1 1...5 10 5 1 1. I cc 2 10 7 8 NZMH 4-... 6 4 3 2 1.../ZM 6 4 3 2 1..5 Breaking Capacity Ue = 480 V 60 Hz 4 3 2 1.5 10 7 8 6 4 3 2 1.5 2 Ue = 480 V 60 Hz 3 4 6 8 10 15 20 30 40 60 80 100 Icc [kArms] For Immediate Delivery call KMParts. ... Let-Through Characteristics Tripping characteristics.N 80 Let-through energy I2t i 2 dt (A 2 s) 10 7 8 6 NZM 7-.Circuit-Breakers. System protection 2h 100 40 Time t Minutes 10 4 1 40 Seconds 10 4 1 400 Milliseconds Milliseconds Seconds 63 100 160 250 A Rated uninterrupted current NZM 7-. Icc 3 2 1.. NZM 7 Tripping Characteristics.. Time t Minutes 2h 40 100 40 10 4 1 40 10 4 1 400 100 40 10 4 1 80 125 200 A Rated uninterrupted current NZM 7-.5 1) NZM 7-250 N 2) NZM 7-160 N 40 30 1) NZM 7-250 N 2) NZM 7-160 N 10 6 8 6 20 15 4 U e = 400–415 V AC 8 3 2 ..N ave 1st hal f-w 60 4 2 . Molded Case Switches Let-through current ÎD ÎD (kA) 100 NZM 7-.. 10 5 8 10 15 20 30 U e = 400 – 415 V AC 10 10 15 20 30 40 60 80 100 Icc [kArms] 40 60 80 100 Icc [kArms] 8/74 For Immediate Delivery call KMParts.com at (866) 595-9616 .. 100 40 10 4 1 40 100 200 400 1000 2000 4000 10000 A rms 40 100 200 400 1000 2000 4000 10000 A rms Circuit Breakers Disconnect Switches. ..9 kA 40 100 200 400 1000 2000 4000 10000 20000 A rms For Immediate Delivery call KMParts.......20 s t v = 0.12) x I r Milliseconds 400 100 40 10 4 1 t v = 0..20 s t r = 2. 1000 ms Irmv = (2.. S.. S/ZMV-250 Tripping time Minutes 2h 100 40 10 4 1 40 10 4 1 200 400 A Setting current NZM 10-400 N ..Circuit-Breakers.. 1000 ms I rmv = (2.... S/ZMV-400 10 4 2 1 40 12 10 6 4 1 600 400 t r = 2. S. Molded Case Switches Seconds Tripping time Minutes Seconds 8 ..12) x I r 1000 2000 4000 10000 20000 A rms With selectivity settings 2h 100 40 125 250 A Setting current NZM 10-400N .12) x I r 100 40 10 4 1 40 100 200 400 Irm = (2..N . NZM 10 Tripping Characteristics Inverse time and Instantaneous response 2h 100 40 125 250 A Setting current NZM 10-..12) x I r Milliseconds 100 40 10 4 1 40 100 150 300 500 250 1000 2000 4000 10000 20000 A rms 1500 3000 6000 I rm = 1.6 kA I rm = 1.. H/ZM-250 Minutes 2h 100 40 Tripping time 200 400 A Setting current NZM 10-400 N . H/ZM-400 Tripping time Minutes 10 4 1 40 10 4 2 1 400 10 4 1 40 Seconds Seconds 10 4 1 400 Milliseconds 40 10 4 1 40 100 150 300 500 1000 250 2000 4000 3000 10000 20000 A rms Milliseconds 100 I rm = (2.com at (866) 595-9616 8/75 Circuit Breakers Disconnect Switches...... 12) x I r I rmv = 1... 1000 ms t r = 2.. H/ZM-630 10 4 1 40 10 4 1 40 Seconds 10 4 1 400 Seconds 10 4 1 400 t v = 0.12) x I r 100 40 10 4 1 I rm = (2.5 106 1H alf-c ycle 1H alf -cy cle Circuit Breakers Disconnect Switches..Circuit-Breakers..com at (866) 595-9616 .. 8 Let-through current ÎD ID(kA) NZM 10 H Let-through energy I2t i 2 dt [A 2 s] NZM 10 H 600 V 480 V 240 V 60 80 100 150 200 Icc [kArms] 10 15 20 30 40 50 60 80 100 150 200 Icc [kArms] 8/76 For Immediate Delivery call KMParts. starting from cold.9 kA 1000 2000 4000 10000 20000 A rms 40 100 200 400 1000 2000 4000 10000 20000 A rms 100 90 80 70 60 600 V 50 40 30 20 15 10 10 15 20 30 40 50 107 9 8 480 V 240 V 7 6 5 4 3 2 1.20 s Milliseconds Milliseconds 100 40 10 4 1 40 100 200 400 I rm = (2.. Molded Case Switches The tripping characteristics show the tripping time of the breakers in relation to the response current.. S. The mean values of the tolerance bands are indicated at an ambient temperature of 20˚C. S/ZMV-630 NZM 10-630N . NZM 10 Tripping Characteristics Inverse time and Instantaneous response 2h 100 40 Minutes Tripping time With selectivity settings 2h 100 40 Minutes Tripping time 300 630 A Setting current 300 630 A Setting current NZM 10-630N ... 2 # 5..25 18 0.3 5 0.NA 250 NZMH 9. CSA 22.3 10 0. 2) Type NZM 12-. ˚C Open –25/+55 (Lower temperatures on request) Enclosed –25/+40 (Lower temperatures on request) 90° 90° Mechanical shock resistance 25 g (shock duration 20 ms) 1) Type NZMH 4-.2 50/33 0.com at (866) 595-9616 8/77 Circuit Breakers Disconnect Switches.2 50/45 0. /ZM9A..5 — — — — 125 0.25 13 0.25 14 0.2 65 0.Molded Case Circuit Breakers.7 35 0.3 — — — — 8 . constant. NZM(H)9.2 95 0. /ZM9A.2 50/45 0..-CNA 80 NZM 6B.3 10 0.25 18 0....3 35 0..25 28 0.2 75 0..1 IEC/EN 60 947-2.NA 1000 V V kA 8000 500 220 8000 690 275 8000 690 275 8000 690 73 8000 690 220 — — — — — — — kA kA kA 30 20 12 30 20 12 30 20 12 25 20 15 35 30 25 — — — kA kA kA — — — 25 25 14 100 65 25 30 25 18 200 85 42 65 65 50 Mounting position Standards Climatic proofing UL 489. Molded Case Switches kA cos ø kA cos ø kA cos ø kA cos ø kA cos ø kA cos ø kA cos ø kA cos ø 100 0..3 20 0.... VDE 0660 1) 90° 90° Damp heat. cyclic.2) /ZM(A)./max.25 18 0.25 20 0...2 100/65 0.25 35 0.3 5 0..... /ZM6A.5 100 0.NA 125 NZM 9.2 75 0.-CNA Thermal-Magnetic devices (16 – 80 Amps) are rated as circuit breakers per IEC/EN 60 947-2 only. Consult page 8/ 5 for further info.2 33 0.. Consult Moeller Electric for IEC/EN rated versions. to IEC 60 068-2-30 Ambient temperature. Disconnect Switches Technical Data for NZM H4.25 35 0.3 25 0... min.2 75/68 0...5 10 0.2 100/90 0.. For Immediate Delivery call KMParts.NA circuit breakers are UL/CSA only.7 125 0.. to IEC 60 068-2-3 Damp heat. NZM 12 1 2 3 4 1) 5 6 7 8 Molded Case Circuit Breakers Frame Size IEC 60 947-2 Circuit Breaker Electrical Ratings Rated impulse withstand voltage Uimp Rated operational voltage Ue 50/60 Hz Rated short-circuit making capacity Icm Short Circuit Interrupting Ratings: Icu IEC/EN 60 947 Test cycle O-t-CO Ics IEC/EN 60 947 Test cycle O-t-CO-t-CO 220 – 240 V 50/60 Hz Icu Icu 380-400/415 V 50/60 Hz Icu Ics 500 V 50/60 Hz Icu Ics 660/690 V 50/60 Hz Icu Ics DC voltage T ≤ 15 ms 110 V DC 250 V DC 440 V DC UL 489/CSA 5 Short Circuit Interrupting Ratings 240 V 60 Hz 480 V 60 Hz 600 V 60 Hz General technical data 3-pole A NZMH 4 . NZM(H)6(B).2 100/90 0.NA 125 NZM H6.2 95 0.3 20 0.2 100/90 0. /ZM6A..25 18 0..NA 250 NZM 12. 3 NZMH 9.8 2.5 10 PKZM 0–2...8 (0..7 (0.3 6 6 12 25 ms ms 10 – 20 15 – 20 10 – 20 15 – 20 10 – 20 15 – 20 10 – 20 15 – 20 10 – 20 15 – 20 15 – 25 20 – 25 8 A A A A A A A Ops. RHI auxiliary contacts 3) IEC/EN 60 947 Ratings Rated operational current Ie AC-15 115 V 50 Hz 230 V 50 Hz 400 V 50 Hz DC-13 (L/R ≤ 200 ms) 24 V DC 60 V DC 110 V DC 220 V DC Lifespan.5 3.. AHI.8 (0.3 10000 2500 A gL PKZM 0–2.8 0.. Ops. 3) For IEC/EN 60 947 ratings....1) 20000 7500 6 6 4 1 0...8 (0. 8/78 For Immediate Delivery call KMParts.7 (0.. 2) Type NZM 12-.3 (0. NZM(H)9. NZM(H)6(B).com at (866) 595-9616 .5 10 Pilot Duty A 600/P 600 C 300 A 600/P 600 C 300 A 600/P 600 A 600/P 600 C 300 A 600/P 600 C 300 A 600 A 600 1) Type NZMH 4-.3 20000 5000 6 (1) 6 (1) 4 (1) 1 (1) 0.2) 0.8 0..7 (0. values which appear in parenthesis apply to VHI.3 (0.3 NZM 12.5 10 PKZM 0–2.6 Circuit Breakers Disconnect Switches.5 10 PKZM 0–2.NA 250 63 – 250 — 0.NA 250 63 – 250 — 0..NA 125 15 – 125 — 0..4) 0.5 10 PKZM 0–2.8 2.1) 20000 5000 6 (1) 6 (1) 4 (1) 1 (1) 0.3 5 3 0.3 6 3 0. VHI.8 85 – 110 70 – 35 10 – 15 6.7 NZM H6.5 10 PKZM 0–2. and RHI contacts.3 6 4 6 20 4 0.5 2..8 85 – 110 70 – 35 10 – 15 40 7 1.1) 20000 7500 6 (1) 6 (1) 4 (1) 1 (1) 0.3 (0.5 2...CNA1) 80 4 – 80 — 0. Disconnect Switches Technical Data for NZM H4. /ZM9A. /ZM6A. Molded Case Switches Shunt Trips Pull-in Voltage range Minimum command time Inrush Rating AC Sealing AC Inrush Rating DC (intermittent duty operation) Switching times Tripping in the event of a short-circuit Minimum command time Opening delay Total opening delay Opening delay with: Shunt Trips (100% of rated coil voltage) Undervoltage Trips NHI..7 0..NA2) 1000 — 300 – 1000 — %Us %Us ms VA VA W W 85 – 110 70 – 35 10 – 15 6. electrical to AC-15 to DC-13 Short-circuit rating without welding (contacts closed) Fuseless Fuses UL/CSA Pilot Duty Ratings Type NHI Type VHI.NA 125 15 – 125 — 0.7 (0.8 85 – 110 70 – 35 10 – 15 6.5 2. /ZM9A.NA circuit breakers are UL/CSA only..3 NZM 6B.8 2..4) 0. AHI..9 85 – 110 70 – 35 10 – 15 100 12 160 3.5 3..8 (0. Otherwise...1) 20000 5000 6 (1) 6 (1) 4 (1) 1 (1) 0. Consult page 8/5 for further info.7 0.2) 0. /ZM6A.2) 0.9 85 – 110 70 – 35 10 – 15 40 7 1.4) 0.7 NZM 9.9 1.4) 0.Molded Case Circuit Breakers. Consult Moeller Electric for IEC/EN rated versions. values apply to all contacts. /ZM(A).5 3.2) 0.. 6 6 4 1 0.-CNA Thermal-Magnetic devices (16 – 80 Amps) are rated as circuit breakers per IEC/EN 60 947-2 only.3 (0. RHI % Us ms VA VA W 70 – 110 10 – 15 50 — 40 70 – 110 10 – 15 50 — 40 70 – 110 10 – 15 50 — 40 70 – 110 10 – 15 150 15 120 70 – 110 10 – 15 150 15 120 70 – 110 10 – 15 350 20 200 ms ms ms 2 0. AHI.. NZM 12 1 2 3 4 5 6 7 8 Molded Case Circuit Breakers Frame Size Overload Trips Bimetal Type (directly heated) Solid State Type Temperature compensation residual error in the range –25/+55 ˚C (reference 20 ˚C) Undervoltage Trips Pull-in Voltage range Dropout voltage range Minimum command time Inrush Rating AC Sealing AC Inrush Rating DC Sealing DC Amps Amps Amps %/K NZMH4.9 1. x 103 8000 3 20000 60 10 5 1 Page 8/15 Page 8/78 Page 8/77 8000 7 20000 60 10 5 0.-CNA NZM(H)6(B)/ZM6-. AC-3 DC-2.. NZM 12 1 2 3 4 5 UL/CSA Motor Disconnect Switches with adjustable thermal and magnetic trips IEC/EN Molded Case Circuit Breakers Frame Size Motor Disconnect Switches with adjustable thermal and magnetic trips General Technical Data IEC/EN 60 947-2 Circuit Breaker Ratings UL 508/CSA 22. x 103 Ops. 78 15 – 125 Page 8/14 Page 8/78 Page 8/77 Page 8/77. electrical AC-1 AC-2..... 78 63 – 250 Page 8/24 Page 8/78 Frame Size Motor Disconnect Switches without adjustable thermal and magnetic trips General Technical Data IEC/EN 60 947-3 Switch Disconnector Ratings: Rated Impulse Withstand Voltage Rated short-time withstand current Icw (1 s current) Lifespan..CNA N 12-... DC-5 UL 508/CSA 22.. NZM(H)9.5 Page 8/33 Page 8/78 90° 90° 90° For Immediate Delivery call KMParts. Voltage Trips 3-pole NZMH 4-. NZM(H)6(B).CNA Amps 80 125 250 Page 8/77 Page 8/77. Disconnect Switches Technical Data for NZM H4.5 Page 8/25 Page 8/78 Page 8/77 8000 20 30000 60 10 5 0.Molded Case Circuit Breakers.com at (866) 595-9616 8/79 Circuit Breakers Disconnect Switches./h Ops.CNA NZM(H)9/ZM 9-.2 # 14 Motor Disconnect switches HP Ratings Auxiliary Contacts. x 103 Ops.CNA N 9-. Ops. mechanical Maximum operating frequency Lifespan.2 # 14 Motor Disconnect switches Adjustable range of thermal overload trips HP Ratings Auxiliary Contacts.. Molded Case Switches UL/CSA Motor Disconnect Switches without adjustable thermal and magnetic trips IEC/EN Switch-Disconnectors 3-pole N 6-.CNA 8 . 78 Amps HP 4 – 80 Page 8/5 Page 8/78 Page 8/77 Page 8/77. Voltage Trips Mounting Position 1) 90° Amps 150 250 1200 Page 8/77 V kA Ops. .. Consult Moeller Electric for IEC/EN Conductor Cross-section information.-CNA 250 N 12-./ZM 6(A).-(C)NA NZM(H) 9.. 8/80 For Immediate Delivery call KMParts......-NA 800 1 Conductor: Kcmil 250 – 600 2 Conductors: AWG 3/0 – Kcmil 500 3 Conductors: Kcmil 250 – 400 Cu + Al 1000 4 Conductors: AWG 2 – Kcmil 500 Cu + Al Circuit Breakers Disconnect Switches.../ZM 6./ZM 9..-CNA 100 150 N 9-..... Disconnect Switches Technical Data for NZM H4. are dual rated UL/CSA and IEC/EN..-OBI-CNA 100 1 Conductor: AWG 14 – 1/0 Cu Only Up to 90A... NZM(H)6(B). NZM(H)9.. 60/75˚C Cable 100A....-(C)NA NZM(H)6(B).../ZM 12(V)(A)-... NZM 12 Type Maximum continuous current A NZMH 4-.....com at (866) 595-9616 . 60˚C Cable 10 NZM(H)6(B)-160/ZM 6(A)-125-(C)NA NZM(H)6(B)-160/ZM 6-125-OBI-CNA 125 1 Conductor: AWG 4 – 3/0 Cu Only 125A... 60˚C Cable 15 Field Wiring Terminals Conductor Cross-Section Terminal Torque Rating Nm 4 4 Type Maximum continuous current A NZM(H) 9.Molded Case Circuit Breakers.-CNA 80 1 Conductor: AWG 14 – 3 Cu Only NZM(H)6(B). Molded Case Switches Field Wiring Terminals Conductor Cross-Section Terminal Torque Rating Nm 40 50 50 Type Maximum continuous current Field Wiring Terminals Conductor Cross-Section A N 6-.-OBI-CNA 18 1 Conductor: AWG 14 – 3 Cu Only NZMH 4-..-OBI-CNA 250 1 Conductor: AWG 8 – Kcmil 300 Cu only NZM12-./ZM 9(A).-CNA 800 1000 1200 8 1 Conductor: AWG 14 – 1/0 Cu Only 75˚C Cable 1 Conductor: AWG 4 – 3/0 Cu Only 75˚C Cable 1 Conductor: AWG 8 – Kcmil 300 Cu Only 1 Conductor: Kcmil 250 – 600 2 Conductors: AWG 3/0 – Kcmil 500 3 Conductors: Kcmil 250 – 400 Cu + Al 50 4 Conductors: AWG 2 – Kcmil 500 Cu + Al 4 Conductors: AWG 2 – Kcmil 500 Cu + Al Terminal Torque Rating Nm 10 15 40 50 50 Note: All devices shown above except Types NZM 12-.. .. Consult Moeller Electric for IEC/EN version.-N-NA molded case circuit breaker UL/CSA only. to IEC 60 068-2-3 Damp heat. Technical Data for NZM 7... Conformity with data shown per IEC/EN 60 947-2 pending. Molded Case Switches 8 . up to 90˚ in any direction 90° –25/+40 (At 100% loading ) 20 g (shock duration 20 ms) 90° 90° 90° 1) Type NZM 7(A)-.... NZM 10.Molded Case Circuit Breakers.N-NA1) NZM 10-.. VDE 0660 Finger-Safe. to IEC 60 068-2-30 Mounting From a vertical position. CSA 22.1 IEC/EN 60 947-2. constant...com at (866) 595-9616 8/81 Circuit Breakers Disconnect Switches.5 8000 690 III/3 143 8000 690 III/3 220 8000 690 III/3 440 kA kA kA kA kA kA kA kA kA kA kA 45 45 35 35 25 19 12 9 6 6 65 33 45 23 45 23 30 15 20 10 100 50 65 33 55 28 42 21 25 13 200 100 100 50 85 43 65 33 30 15 UL 489/CSA 5 Short Circuit Interrupting Ratings 240 V 60 Hz 480 V 60 Hz 600 V 60 Hz kA kA kA 65 25 — 65 42 35 100 65 42 200 100 50 General technical data Standards Shock Hazard Protection Climatic proofing Ambient temperature Min/Max ˚C Mechanical shock resistance UL 489. cyclic..N-NA NZM 10-. 1 2 3 4 5 6 Molded Case Circuit Breakers Frame Size IEC 60 947-2 Circuit Breaker Electrical Ratings Rated impulse withstand voltage Uimp Rated operational voltage Ue 50/60 Hz Overvoltage category/pollution degree Short Circuit Interrupting Ratings: Rated short-circuit making capacity Icm Rated short-circuit breaking capacity Icn Icu IEC/EN 60 947 Test cycle O-t-CO Ics IEC/EN 60 947 Test cycle O-t-CO-t-CO 230 V AC Icu Ics 400/415 V AC 440 V AC 500 V AC 690 V AC Icu Ics Icu Ics Icu Ics Icu Ics V V Amps NZM 7(A).S-NA NZM 10-. Back of Hand safe Damp heat....2 # 5.H-NA 150 600 600 600 8000 690 III/3 94.. For Immediate Delivery call KMParts. .5 18 – 14 48 – 240 24 – 240 0.85 – 1.5 – 2..85 – 1.5 – 2.5 18 – 14 A 600/ P 300 — Short-circuit protection: Max.7 – 1.85 – 1. Fuse.5 0.75 – 2. solid or stranded UL/CSA Remote Control Drives Rated Control Voltage Us Operating range Power Draw Total closing/opening time Lifespan.7 0.5 18 – 14 — 10A @ 600 VAC .35 x Us 0./h mm2 AWG 12 – 480 12 – 125 0.75 – 2. IEC Type Max.1 x Us 2/2 — 24– 480 24 – 125 0. EK.1 x Us 240 320 440 240 240 240 — 240 60/30 10000 20 0..5A @ 125 VDC .85 – 1. Molded Case Switches Voltage Trips Shunt Trip Operational voltage rating Ue Operating range (Us = Rated Control Voltage) Rating Pull-in Sealing Undervoltage Trips Operational voltage rating Ue Operating range: Rating: Dropout Pickup Pull-in Sealing AC/DC DC/DC AC/DC AC/DC AC/DC AC/DC V AC V DC AC DC VA/W VA/W V AC V DC VA/W VA/W mm2 AWG V AC V DC AC DC 110/120 V AC 220/240 V AC 380/415 V AC 24 V DC 48/60 V DC 100/130 V DC 110/120 V DC 220/240 V DC Operations VA VA VA W W W W W ms Ops.7 – 0.7 – 1.1 x Us 0.com at (866) 595-9616 . Ops...75 – 2.8 – 1.5 18 – 14 24 – 600 24 – 600 0.1 x Us 5/3 5/3 0.1 x Us 400 400 1000 350 400 — 400 400 100 20000 20 0.7 – 0. solid or stranded UL/CSA UL/ CSA Electrical Ratings Pilot Duty Ratings AC/DC Current Ratings Circuit Breakers Disconnect Switches.8 0.7 – 1.25A @ 250 VDC1) DC-13 115 V 230 V 400 V 500 V 24 V 60 V 110 V 220 V A A A A A A A A A A mm2 AWG 6 6 4 2 6 3 1 0.5 18 – 14 8 Terminal capacity IEC/EN: 1 or 2 conductors.. 1 2 3 4 5 6 Molded Case Circuit Breakers Auxiliary contact types IEC/EN 60 947 Electrical Ratings Rated operational current Ie AC-15 AC = 50/60 Hz NZM 7.5 18 – 14 110 – 415 24 – 240 0..2 10 6 0..5 1 0..1 x Us 2/2 2/2 0.1 x Us 0.1 x Us 5/3 3/3 24 – 600 24 – 600 0.35 x Us 0.1 x Us 0.5 18 – 14 C 300/ Q 300 — NZM 10..5 – 2. solid or stranded UL/CSA 1) Above 150 VDC.Molded Case Circuit Breakers Technical Data for NZM 7. same polarity 8/82 For Immediate Delivery call KMParts.1 x Us 0.(NHI/RHI) VHI 4 4 2 1 3 1. Miniature Circuit Breaker Terminal capacity: IEC/EN: 1 or 2 conductors.. NZM 10. mechanical Maximum operating frequency Terminal capacity: IEC/EN: 1 or 2 conductors.5 10 10 0.85 – 1.3 6 6 0.5 0. NHI/RHI/VHI 6 6 3 1.75 – 2.85 – 1. ../ZM 9A-...2 # 5.-NA Molded Case Switch 200 1 Conductor: AWG 14... Terminal Capacity 1 2 3 4 UL/CSA Molded Case Switches IEC/EN Switch-Disconnectors Frame Size General Technical Data UL 1087/ CSA 22.N-NA Molded Case Circuit Breaker 150 1 Conductor: AWG 14. and 10..250 kcmil Cu Only 14 NZM 7-. 8/45 V kA Ops.5 10 430 42 26 1300 65 35 2100 600V 7.6 468 14 16 1000 25 21 1590 250 240V 16..-NA-M8 Molded Case Switch M8 Refer to Page 8/71 NZM 10.25 18 1500 100 36 1800 200 42 3200 480V 16. electrical AC-1 400 V/690 V A NZM 7-..25 23 2204 30 32 5000 42 39 6300 600 240V 39 34 2800 125 50 3500 200 55 4000 480V 39 42 5500 65 52 6600 100 61 8000 600V 39 40 5500 42 45 7200 50 48 8000 Current Limiting Values @ Threshold Current RMS Sym kA Peak kA I2t x 103 A2s Intermediate Current RMS Sym kA Peak kA I2t x 103 A2s High Interrupting Capacity RMS Sym kA Peak kA I2t x 103 A2s For Immediate Delivery call KMParts./h Ops.../ZM 6A-..... 8000 3. 8/61 8000 8 III/3 20000 60 10000 Terminal Capacity Type Maximum continuous current Field Wiring Terminals Conductor Cross-Section A NZM 7(A)-. Technical Data.N/B-NA 600 Refer to p...-NA Molded Case Circuit Breakers and Switches Terminal Torque Rating Nm Let-Through Values for UL/CSA Fuseless Current Limiting Circuit Breakers 1 2 3 4 Type Maximum continuous current A NZMH 6-.-NA 125 240V 7...Molded Case Switches.-NA NZM 10H-.5 10.... NZM 7......25 21 2000 50 38 5000 85 48 6000 600V 16. mechanical Maximum operating frequency Lifespan.. Ops..com at (866) 595-9616 8/83 Circuit Breakers Disconnect Switches.-NA 200 Refer to p..2 Molded Case Switches IEC/EN 60 947-3 Switch Disconnector Ratings: Rated Impulse Withstand Voltage Rated short-time withstand current Icw (1 s current) Overvoltage category/pollution degree Lifespan.250 kcmil Cu Only 14 NZM 7(A)-..5 9 350 50 22 800 100 30 1000 480V 7..N-NA-M8 Molded Case Circuit Breaker Bolt-on Connection size M8 NZM 7-../ZM 10(A)-.-NA NZMH 9-. Molded Case Switches 1 2 3 4 8 .5 III/3 20000 120 3000/2000 NZM 10.. ...Molded Case Circuit-Breakers and Disconnect Switches Dimensions for Type NZMH 4.-CNA +A-NZMH 4 +U-NZMH 4 12 12 90 82 58 +h 58 16 95 20 4 12 Drilling Template 82 75 6 98 +R 30..-CNA — NZMH 6/ZM 6(A)-(C)NA 210 NZM 6 B/ZM 6(A)-(C)NA 210 18 16 11 +h 42 18 206 240 217 211 279 285 322 211 206 45 58 +R 26 45 279 SVB ~40 + MV +h 126 10 X5 Circuit Breakers Disconnect Switches.NZM 94 SVB ~40 +h 8 N 9-.-CNA NZM 9/ZM 9(A)-...CNA 140 NZM 9/ZM9. 6 and 9 Circuit-breakers NZMH 4-.. Molded Case Switches 1) b g 66 +A-NZM +U-NZM 55 5 110 16 k Drilling Template g +h 15 12 58 a1 e h f f h 4..5 38 d a 6 +R 55 38 70 +2 M 4¥ 45 b1 b 84 42 +A-NZM +U-NZM 32.5 138 160 98 75 30. 8/84 For Immediate Delivery call KMParts...-CNA NZMH 6/ZM 6(A)-(C)NA NZM 6B/ZM 6(A)-(C)NA NZM(H)6B/ZM 6-OBI-CNA Type a a1 133 — — b 109 109 109 d — 180 180 e 125 — — f 92 112 112 g 95 95 95 h 106 126 126 k 7 7 7 N 6-.5 144 64 N94...5 4...(C)NA NZMH 9/ZM 9(A)-.-OBI-CNA NZMH 4-..com at (866) 595-9616 .-NA 140 NZMH 9/ZM9... Front switch shaft is then omitted except for frame sizes 4 and 6.3 4 16 3 M 4¥ 50 50 +h N6-.-NA 140 3 M5 ¥ 40 4 M5¥ 40 126 59 4..2 Notes: Safety vertical clearance between upper edge of NZM circuit-breakers and conductive materials with a different potential: Type NZM 4 NZM 6 NZM 9 40 mm 60 mm 100 mm +R: When switch shaft extended to the rear: provide 20 mm diameter hole in mounting plate for switch shaft.(C)NA NZMH 9/ZM 9-OBI-CNA 10 15 Type b b1 — — — N 9-. .... Molded Case Switches 105 474 525 8 . NZM12...Molded Case Circuit-Breakers and Disconnect Switches Dimensions for Type NZM 12 N12...5 10 800 10 8.2 184 60 79 6 59 10 166. 800) NZM 12-..2 184 N12..com at (866) 595-9616 8/85 Circuit Breakers Disconnect Switches. 6 M6 x 20/ 4 M8 x 20 65 32 516 99 +R 99 65 32 118 69 Type Terminal bolts M16 x 50 630 1000 a b b 8 8. 248 296 197 M6 M8 9 NZM12.5 10 1250 10 8. 248 296 59 40 79 79 9 6 60 b 166...5 15 NZM 12 ZM 12 N 12-1200-CNA +K 240 AL-NZM 79 15 79 Notes: Safety vertical clearance between upper edge of NZM circuit-breakers and conductive materials with a different potential: Type NZM 12 180 mm For Immediate Delivery call KMParts./ZM 12 (A)(V)-.-CNA (630..-NA (630. 800) N 12-1000-CNA NZM 12-1250/ZM (V)-1000-NA 190 46 25 276 112 46 40 +h +K300 94 a 190 +h 25 94 a 276 112 276 79 69 65 12 109 65 118 420 320 142 319 516 420 320 142 588 537 319 99 118 65 12 +R 588 537 197 N12.. Molded Case Circuit-Breakers and Disconnect Switches Dimensions for Type NZMH 4.com at (866) 595-9616 .5 11 5° 84 60° + 1 0 15 70 15° 2–5 51 84 60° 51 50 4.5 11 5° 84 15° 51 2–5 0 15 60° 51 For NZM 9 H9U 52 8 H 9(-NA) 11 5° 155–163 H 9 R(-NA) 40–45 58 90 90 4 10 2–5 5 11 ° 10 4 15° 18 0 2–5 63 60° 63 For NZM 12 H 12 U H 12(-NA) H 12 R(-NA) 76 2–5 114 194–209 76 114 0 + 1 11 40–45 5° 0 19 16 0 5° 11 0 21 19 0 2–5 60° 8/86 For Immediate Delivery call KMParts.5 60 58 52–54 62° 0 +1 60° 87 15 ° Circuit Breakers Disconnect Switches. 9 and 12 Standard handle Door coupling rotary handle d Handle for switch shaft extended to rear b d = 6–8 mm b = min.5 H 6 R(-NA) Mounting opening as on left. but turned clockwise through 90˚ 2–5 36–44 0 60° 52 50 28–30. 6. 36 mm For NZM 4 H4U 35 33 H 6(-NA) 5–5.5–5 60° 67 93 60° 38–40 5–5. but turned clockwise through 90˚ 11 117–122 5° 2–5 36–44 0 + 1 70 60° 60° 52 70 84 70 28–30. Molded Case Switches For NZM 6 H6U 40 38 H 6(-NA) 5–5.5 H 6 R(-NA) 11 5° 104–107 70 Mounting opening as on left. 9 and 12 K(V). 6.Molded Case Circuit-Breakers and Disconnect Switches Dimensions for Type NZMH 4.com at (866) 595-9616 8/87 Circuit Breakers Disconnect Switches. Molded Case Switches 8 . KU coupling kits KV-2 NZM a 2–5 Type a b a 125 125 150 300 b 145–185 150–190 190–240 240–300 NZM 4 NZM 6 a a NZM 9 NZM 12 a For Immediate Delivery call KMParts. VHI-NZM 7 93..com at (866) 595-9616 40 69 Circuit Breakers Disconnect Switches. Molded Case Switches ..Molded Case Circuit Breakers and Switches Dimensions for Type NZM 7..5 35 105 140 SW 5 Shunt Trips.5 105 23 1) 22. undervoltage Trips and Early-Make auxiliary contacts A-. Molded Case Switches NZM 7..5 34 18 20. Circuit Breakers.5 93 107 122 3.5 28 131. U-.-NA 60 35 4.5 2–8 10 8/88 For Immediate Delivery call KMParts..3 8 Insulating frame RT-NZM 7 Mounting opening for insulating frame 4 62 13 6 29..5 4 130 139 175 184 R 44.5 M4 x 50 26.5 129. 5 Up to 3 padlocks can be fitted d b Extension shaft A400-NZM = mounting depth 175–400 mm A600-NZM = mounting depth 260–600 mm 7 282 mm (A400-NZM 7) 482 mm (A600-NZM 7) A400(600)-NZM 7 15 5 Door interlocking handle for base mounted breakers and switches (R)H-NZM 7 HOV-NZM 7 52.5 46 87.. 34 mm 8 .0° 48 [ 64 2–5 6 62 48 For Immediate Delivery call KMParts. 34 mm 7 64 40 90 .5 105 140 45.5 DA(O V)-NZM 7 66 52 .5 14 20 Up to 3 padlocks can be fitted d b Mounting opening for door coupling rotary handle 18 0 d = 4–8 mm b = min. Molded Case Switches d = 4–8 mm b = min.com at (866) 595-9616 150 8/89 Circuit Breakers Disconnect Switches.5 52.5 90 ° HU-NZM 7 32.Molded Case Circuit Breakers and Switches Dimensions for Type NZM 7.. Rotary drive/rotary handle for open mounted breakers and switches DA(OV)-NZM 7 HU-NZM 7 27 15 1. com at (866) 595-9616 53 Circuit Breakers Disconnect Switches.5 64. Molded Case Switches 35 105 130 169 17 Cable lug/cable lug cover KA 250-NZM 7 8 M8 M8 .5 8/90 For Immediate Delivery call KMParts.Molded Case Circuit Breakers and Switches Dimensions for Type NZM 7 Mechanical interlock KV-2 NZM 7 approx. 45 125 54 Rotary drive Clip plate C-NZM 7 281 53 105 140 56. .5 48 Remote Control Drive R-NZM 7 Type a 65 NZM 7(A)-...-NA a b 98 232.5 157 189. Molded Case Switches 100 175 48 8 1 0 .-NA 154 134 a b 2–5 63 50–270 a 14 Mounting bracket for side wall operator MSWA-NZM 7 MSWA-NZM7 SWA-NZM7-L Mounting aperture for rotary handle b X 7 X 7 48 83 198 139.2 251 b 58 + 175 d 16 b d = 4–8 mm b = min....Molded Case Circuit-Breakers and Switches Dimensions for Type NZM 7. Side wall operator SWA-NZM 7 36 88 Type 36 NZM 7-. 34 mm Up to 3 padlocks can be fitted 90 109 R-NZM 7 (tilted) For Immediate Delivery call KMParts.N-NA NZM 7-..com at (866) 595-9616 279 8/91 Circuit Breakers Disconnect Switches.. Molded Case Switches 27 H 10 U D-NZM 10 TRIP ON 48. 18. P 10(4)-.-NA 105 75 37 23 When mounting devices side by side.8 4.7 4. 15mm clearance is required between them.5 9.7 286 OFF 30° 7 34 150 210 NZM 10(4)-. Molded Case Switches NZM 10-. 8 (R)H 10-NA Door Interlocking handle Drilling template (R)H 10-NA 158-165 67 11 5° 67 11 5° 2 ..5 2-5 8/92 For Immediate Delivery call KMParts.com at (866) 595-9616 180 15 ° 11 5° 0 5° 11 19..Molded Case Circuit Breakers and Switches Dimensions for Type NZM 10.45 für M6¥ 50 70 70 M12 35 105 197 19 153 245 250 254 9 44 70 70 210 280 K2¥ 120 K300 K2¥ 240 70 28 M-NZM 10(4) Rotary drive D-NZM 10 200 105 43 30 34 13 56. Circuit Breakers.7 R1 5° 5° 0 R3 R 8 Circuit Breakers Disconnect Switches.5 16 1) max... 87 4...5–5 60° 90 38–40 38–40 14 0 64..5 2 30° 46 151 46 286 1) Safety clearance is required to conductive materials having a different potential.. does not apply to connected stripped conductors.5–5 19. Molded Case Circuit Breakers and Switches Dimensions for Type NZM 10. Molded Case Switches 262.5 131 87.8 235 Ground Fault Trip Unit TV-NZM 10 37.5 66 35 90 10 70 34 44 2–5 Protective cover for door cutout RTR-NZM 10 268 200–205 Mounting opening 83 90 83 X 5. Pushbuttons for enclosed breakers/switches operated with a remote control drive MD-NZM 10 MDV-NZM 10 250–285 22 285–400 22 Mounting opening for pushbuttons 67 Ø 5..5 130 M12¥ 35 19 37 70 75 70 70 210 280 105 28 46 M-NZM 10 For Immediate Delivery call KMParts..5 229 80 90 80 8 .com at (866) 595-9616 8/93 Circuit Breakers Disconnect Switches.5 82.5 R 24 5 15 30 21 2–5 61. com at (866) 595-9616 .Notes Circuit Breakers Disconnect Switches. Molded Case Switches 8 8/94 For Immediate Delivery call KMParts.
Copyright © 2024 DOKUMEN.SITE Inc.