Kidde Aegis Conventional Fire Control Panel

March 23, 2018 | Author: Rahul Deva | Category: Relay, Switch, Power Supply, Amplifier, Detector (Radio)


Comments



Description

Kidde AEGIS™Kidde’s New Conventional Control Panel is Everything But Conventional! The Kidde AEGISTM is a fully featured single hazard conventional control panel that is ideal for small- to mid-sized special hazard suppression environments. The AEGIS can be used to control Kidde’s full line of suppression systems—FM-200®, Carbon Dioxide, 3MTM NovecTM 1230 Fire Protection Fluid, ArgoniteTM, FE-13TM, Halon 1301, WHDRTM Wet Chemical and INDTM Dry Chemical, as well as sprinkler supervisory, deluge/pre-action, foam and foam/water systems. This new sleek panel easily fits between studs of a 16-inch standard wall, yet it is large enough to house two 12 VDC, 12 AH batteries with two-inches of wiring and finger space between the circuit board and cabinet wall access. The AEGIS also works well with in-cabinet applications and can be used in conjunction with the Kidde In-Cabinet Suppression System. Kidde AEGIS™ The AEGIS was engineered to be easy to install, fully robust, yet economical as well. Manual Releases and Abort Switches can be mounted directly onto the panel, avoiding the additional expense of wall mounting these items. A range of circuits has been incorporated to allow programming flexibility to handle all types of special hazard extinguishing systems. These features, as well as the many others packed into this control panel, make the AEGIS the most advanced conventional control panel available to the suppression industry today. All backed with a full five-year warranty from Kidde-the most recognized name in fire protection. Kidde AEGIS™ Agency Approvals: • cFMus to NFPA 72, ANSI/UL 864, 9th edition and ULC-S527-99 • CSFM Approved • MEA Approved • cULus to ANSI/UL 864, 9th edition and ULC-S527-99 Kidde Fire Systems—We Are the Right Protection... Every Time, Everywhere, Every Application. www.kiddefiresystems.com excluding the Agent Release Circuits. SS K-012 November 2007 ©Kidde-Fenwal. cutting down the cost of extra materials. Battery Voltage and Charging Display Password Protection A Five Year Warranty Kidde is registered trademark of Kidde-Fenwal. which can significantly reduce costs. Inc. Optionally. A Robust Power Supply Unit (PSU) Power Limited Circuits Independently Programmable Agent Releasing Circuits        Triple-RTM Protection Class A Circuitry Sophisticated Notification Appliance Circuits (NACs) Release Countdown Timer An easy-to-read release countdown timer lets you know exactly when the system is going to discharge. the AEGIS has built-in Class A supervision fo all circuits. The two Agent Release Circuits can be programmed with independent time delays and abort modes to fire combinations of two of the following releasing devices: – 1 or 2 Control Heads (Up to 4 Control Heads with both Agent Release Circuits) – 1 FM Sprinkler Solenoid (2 FM Sprinkler Solenoids with both Agent Release Circuits) – 1 Metron Head This triple redundancy process safeguards the system by ensuring no inadvertent activation of the suppression can occur in case of microprocessor failure. are power-limited thereby allowing the installer to run all wiring through the same conduit. Kidde stands behind the AEGIS. . Class A wiring can be achieved without any additional hardware. If a password is forgotten. As required by many applications. Inc. Furthermore.Kidde AEGIS Features:     Programming Flexibility The range of circuits on the AEGIS allow to program special cases: – Combination Clean Agent plus Double-Interlocked Deluge/Pre-Action Systems – Third Detection Circuit is programmable for either Water flow Input or as a suppression independent detection circuit A 5. the Agent Release circuits can also be converted to power-limited when not using AH Intitators. All circuits. AEGIS is a trademark of Kidde-Fenwal. This ensures continuous fire protection in the event of downtime due to a power failure. All three NACs use a protocol that enables silenceable horns and non-silenceable strobes to be used on the same NAC. Read the open circuit battery voltage and the battery charging current on a working panel without disconnecting the batteries or using external multi-meters! Set a password when you install the panel it ensure the system isn’t tampered with before you stop back to service the panel. which is why we’re extending a five-year warranty for this product. All Rights Reserved. simply call the factory for a temporary daily password.4 Amp PSU! The battery charger is able to charge upto a 68 AH battery thereby allowing for 90-hours of standby supervision plus 10-minutes of alarm—as required by some authorities. Inc. 9th edition and ULC-S527-99 • CSFM Approved • MEA Approved • cULus Listed to ANSI 864. Foam. FE13TM. Preaction. ANSI 864. CO2. and flexibility required by modern commercial. 9th edition and ULC-S527-99 Suppression focused Control Unit Listed for a Wide Range of Suppression Systems • Kidde FM-200®. The AEGIS is well equipped to handle all special hazard extinguishing systems due to the high degree of programming flexibility provided and the following full complement of input and output circuits: • • • • • • • Three (3) Class A or Class B Detection Circuits Two (2) Class A or Class B Supervisory Circuits One (1) Class A or Class B Manual Release Circuit One (1) Class A or Class B Abort Input Circuit Three (3) Class A or Class B Notification Appliance Circuits Two (2) Class B Agent Release Circuits Four (4) Form-C Relays . and Halon Clean Agents • TM TM • Kidde IND Dry Chemical & WHDR Wet Chemical • Systems • • Sprinkler Supervisory Service • • Deluge. 3MTM Novec 1230TM • Input and Output • 3 Detection Circuits • 2 Supervisory Circuits • 1 Manual Release Circuit • 1 Abort Input Circuit • 3 Notification Appliance Circuits • 2 Release Circuits • 4 Form-C Relays Programmable Relays Robust Power Supply Elegant User-Interface Simple Configuration Password Protected Digital Release Countdown Battery Voltage and Charging Current Display Extensive Diagnostics Backwards Compatible Improved and Enlarged Cabinet Design 5-Year Warranty • • • • • • • • • Fire Protection Fluid. system reliability. It combines the high quality.AEGIS™ Conventional Fire Alarm-Suppression Control Unit A UTC Fire & Security Company Effective: November 2007 K-84-100 FEATURES • Agency Approvals • cFMus Approved to NFPA 72. ArgoniteTM. Foam-Water Systems • Combination Clean Agent plus Pre-Action System • Built-in Class-A and Class-B Circuitry • Sophisticated Programmable Notification Appliance • Circuits Independently Programmable Agent Releasing Circuits with Triple-R Protection DESCRIPTION The Kidde AEGIS is the technologically most advanced Conventional Single Hazard Agent Releasing Unit available to the Fire-Alarm Suppression industry today. high-tech and industrial applications in an aesthetically pleasing and physically robust package. NOTIFICATION APPLIANCE CIRCUITS (NAC) The three Notification Appliance Circuits are rated 1. Printed Circuit Board (PCB) -2- .DETECTION CIRCUITS The Detection Circuits can support up to 25 Conventional CPD-705x Ionization Smoke. low air supervisory can be included with detection for release of pre-action systems as required by certain jurisdictions. MANUAL RELEASE AND ABORT CIRCUITS Both the Manual Release and Abort Circuits accept Normally Open contact closure type devices. 120 BPM. For example. The system configuration enables the supervisory input to be a participant in the suppression function. Aborts can also be programmed to be applicable for either one or both Agent Release Circuits thereby allowing use with Deluge/Pre-Action systems. The NACs configuration includes a userselectable intelligent synchronization feature which allows a silenceable horn to be shut off while the strobe continues to flash in synchronized fashion. Agent release can be temporarily delayed by activating the Abort Circuit. and Releasing as well as for 60 BPM. the NYC mode. MANUAL WATERFLOW/ ABORT RELEASE DETECTOR 3 DETECTOR 2 SUPERVISORY 2 SUPERVISORY 1 TB7 TROUBLE RELAY 3 RELAY 2 RELAY 1 TB8 TB6 TB5 TB4 TB3 TB2 TB1 DETECTOR 1 TB9 TB10 TB11 BATT OUT TB12 AC SUPPLY SELECT SWITCH (S6) TB19 NAC 1 AC IN TB13 TB14 TB15 TB16 TB17 TB18 NAC 2 RELEASE 1 ARC 1 RELEASE 2 ARC 2 AUX 24 VDC NAC 3 Figure 1. the IRI mode. Notification Appliance Circuits can be programmed as Non-Silenceable as required by certain jurisdictions. or THD-705x Heat Detectors each as well as Normally Open contact closure type devices. These include the UL 10-second mode. When programmed for Waterflow. The MT and NS series appliances provide the option to use silenceable horns and non-silenceable strobes on the same NAC. Activation of the Agent Release Circuits can either be instantaneous or delayed up to 30 seconds (maximum) upon receipt of Manual Release input. The third Detection Circuit is programmable for either Waterflow or as an independent Detection circuit. Each circuit is driven independently and is user configurable for First Alarm. regardless of any differing starting times that preceded their concurrent operation. The Abort input can be programmed for 5 modes of operation. Pre-Release. or the abort can be disabled. The user-configuration allows automatic release via detection to be delayed from 0 to 60 seconds in 10-second intervals and also allows a choice of which of the two Agent Release Circuits to activate. SUPERVISORY CIRCUITS The Supervisory Circuits accept Normally Open contact closure type devices such as pressure switches on the agent cylinders or on the water or air pipe network. the full-delay mode. PSD-715x Photoelectric Smoke. Multiple NAC circuits (connected to audible devices only) programmed with the same master code pattern are synchronized.5 Amps each and accept polarized 24 Vdc Notification Appliances. Temporal. Two circuits are dedicated to the main suppression function and can be programmed to activate the release circuits by either single-shot or cross-zone input. or Continuous pattern. except when firing Initiators. The 3-digit display provides a countdown of impending agent release. the choice of Class A or Class B supervision is made at site on the board itself by selecting the terminals used for wiring. the AEGIS annunciates its suppression state-of-alarm via three additional Pre-Release. AGENT RELEASE CIRCUITS (ARC) The two circuits can be programmed for activation by different inputs. SIMPLE SITE-SPECIFIC CONFIGURATION Accessed via the digital display and user-interface switches. G. one each for Acknowledge. three are user-programmable for a variety of alarm related conditions and the fourth is a dedicated trouble relay. Input circuit Fire and Trouble and Output circuit Trouble LEDs. ROBUST POWER SUPPLY UNIT (PSU) The AEGIS features a universal 120/240 V. Agent Release Circuits. The Triple-R system requires that in order to activate an ARC. the main microprocessor issues two release commands of opposing polarity via separate channels and that these commands be combined with a third signal from the panel watchdog timer to confirm the microprocessor operation. I. F. with independent time delays and abort modes to fire combinations of two of the following releasing devices: • • • 1 or 2 Kidde Continuous and Momentary Solenoid Control Heads 1 Kidde Initiator 1 Factory Mutual Group A. Factory technical support can provide assistance with lost or forgotten passwords. J. 50/60 Hz AC Power Supply Unit with a robust 5. PROGRAMMABLE RELAYS Of the 4 relays. can also be made power-limited by a field located inline releasing diode device thereby allowing cost effective installation with all wiring in the same conduit. Duct Detectors. it also indicates the battery open circuit voltage and charging current. excluding ARCs are inherently power-limited. the two circuits can release: • • • • • 1 or 2 Control Heads on ARC1 and 1 or 2 Control Heads on ARC2 1 or 2 Control Heads on ARC1 and 1 Initiator on ARC2 or vice-versa 1 or 2 Control Heads on ARC1 and 1 FM Sprinkler Solenoid on ARC2 or vice-versa 1 Initiator on ARC1 and 1 Initiator on ARC2 1 FM Solenoid on ARC1 and 1 FM Solenoid on ARC2 This configurability is useful for those jurisdictions where the gaseous suppression agent is required to be supplemented with a pre-action system. System Reset and Output Disable. -3- . EXTENSIVE DIAGNOSTICS Also initiated via the digital display and user-interface switches. Apart from the input voltage selection performed on both the PSU and main board via a slider switch. the troubleshooting function displays diagnostic codes that assist in determining causes of trouble. On command from the userinterface switches. Signal Silence. Neither conversion boards nor additional hardware nor jumper selection is required for this purpose. a Digital Display. Input voltage selection is via a slider switch with no jumper cutting required. AlarmLine modules. E.0 Amps at 30 Vdc/120 Vac (resistive). site-specific configuration is simple. D. and Buzzer. The Triple-R system ensures that electrical transients or disturbances such as power surges that could interfere with the operation of the main microprocessor will not inadvertently activate the connected suppression system. Control Switches. etc. AUXILIARY POWER SUPPLY Up to 1 Amp of auxiliary power at 24 Vdc is available to power external 4-wire devices such as Flame Detectors. Four switches are provided. operating in tandem. ELEGANT USER-INTERFACE The user-interface consists of an array of LED Indicators. In other words. All relay contacts are rated 3. B. no other onboard settings or jumper cuttings are required. A complete list of diagnostic codes and their meaning ships factory installed on the inside of the enclosure door for easy reference. Over and above the System.4 Amps of 24 Vdc power. Power Supply status. the configuration menu is protected by a user-changeable password. yet detailed and can typically be performed in a matter of minutes.BUILT-IN CLASS A AND B CIRCUITRY For the input and NAC circuits. TRIPLE-R PROTECTION FOR AGENT RELEASING CIRCUITS (ARC) The two ARCs feature a triple failure redundancy safeguard system to protect them from inadvertent activation by the main microprocessor. The result is a more robust and reliable suppression-focused panel. or K Solenoid POWER-LIMITED CIRCUITRY All circuits. To prevent unauthorized use. The on-board battery charger is able to charge 24 Vdc (2 x 12) batteries of capacity up to 68 Ah thereby allowing from 24 hours of supervision plus 5 minutes of alarm to 90 hours of supervision plus 10 minutes of alarm required by some jurisdictions. Releasing and Post Release LEDs. Factory configured as Class B/Style Y .Compatible with polarized 24 VDC Audio-Visual devices . or 1 initiator. 47 to 63 Hz) AC Main Input .DET3/WF configurable for detection or waterflow • One (1) Manual Release Circuit .Power-limited .Battery capacity up to 68 Ah @ 24 Vdc .Configurable as Class A/Style D or Class B/Style B . Other cabinet options include a flush mounting trim-ring and a dead-front plate required for Canadian applications.Each compatible with 1 or 2 control heads.Auxiliary power output rated at 1 Amp at 18. An optional door design features a Manual Release and Abort switch for applications with space constraints.4 Amps at 27 Vdc Output .Supervised for ground faults. TECHNICAL SPECIFICATIONS (cont’d) • One (1) Abort Circuit .6 Vdc (resettable) • Three (3) Detection Circuits . 50/60 Hz (90 to 264 Vrms.3 independently programmable.Supervised for ground faults and open circuits .Power-limited • Three (3) Notification Appliance Circuits (NACs) .Circuits electrically capable of simultaneously releasing any combination of two of the above devices .1 dedicated normally energized Form-C Trouble Relay . normally deenergized Form-C .BACKWARDS COMPATIBILITY Consistent with previous generation Kidde control equipment.5 Amps each .Compatible with normally open contact-closure type devices . or 1 FM sprinkler solenoid .One Power Supply .Power limited . May be power-limited (except with initiators) and supervised for short circuit using inline releasing resistor-diode device .Supervised for ground faults and open circuits .Non-power-limited. PSD-715x. and THD-705x detectors and normally open contact-closure type devices . Going forward. Both switches incorporate guards that prevent their inadvertent activation.8 .Common NAC/ARC output disconnect switch • Two (2) Agent Release Circuits .Compatible with normally open contact-closure type devices .Supervised for ground faults and open circuits .Power limited -4- .5.Configurable as Class A/Style D or Class B/Style B .DET 1 and DET 2 used for suppression .Supervised for ground faults and open circuits .120/240 Vac. It is large enough to house two 12 Vdc.Compatible with up to 25 CPD-705x. 12 Ah Batteries and provides up to 2 inches (51 mm) of wiring and finger space between the circuit board and the cabinet wall.Configurable as Class A/Style D or Class B/Style B .Power-limited • Two (2) Supervisory Circuits .27.Rated at 1. and open circuits .Relay contacts rated 3 Amps at 30 Vdc/120 Vac (resistive) TECHNICAL SPECIFICATIONS • • Hazards Protected .Configurable as Class A/Style Z or Class B/Style Y . alarm devices and suppression accessories. IMPROVED AND ENLARGED CABINET DESIGN The cabinet design allows for easy installation by fitting between the studs of a standard 16 inch studded wall. the AEGIS is listed to be backwards compatible with the full range of Kidde-Fenwal conventional detectors.Supervised for ground faults and open circuits .Configurable as Class A/Style D or Class B/Style B . this will allow older generation panels to be replaced with relative ease. shorts.Common NAC/ARC output disconnect switch • Four (4) Relays .Compatible with normally open contact-closure type devices . and EOL resistor kit .Red color .Suitable for wall and surface mounting .Humidity: 93 ± 2% RH at 90 ± 3°F (32 ± 2°C) • Packaging/Shipping . IOM manual on CD-ROM.Optional Dead-Front Panel .Dimensions: . W x 5 in. W x 6 in.Enclosure. PCB.Optional Trim Ring .Accessories shipped include mounting hardware. and PSU packaged in individual cartons . order Control Unit and Dead-Front Panel separately. -5- .Operating temperature range: 32°F to 120°F (0°C to 49°C) . D x 19 in.TECHNICAL SPECIFICATIONS (cont’d) • Enclosure .with Switch Door: 14-1/4 in. H (362 mm x 127 mm x 483 mm) .with Standard Door: 14-1/4 in.Order inline releasing resistor-diode device (if required) and batteries separately ORDERING INFORMATION Description Kidde AEGIS Control Panel Kidde AEGIS Control Unit with Switches In-Line Releasing Diode (10K) Kit Trim Ring Dead-Front Panel* Battery Enclosure Kidde AEGIS Conventional Fire Alarm-Suppression Control Unit IOM Manual Kidde AEGIS User’s CD Installation/Configuration Kit Operating Instructions Replacement Hardware Installation Kit Replacement Enclosure Assembly Replacement Enclosure Assembly (with Switches) Replacement Switch Kit Replacement PCB Assembly Replacement Power Supply Replacement Bezel Assembly Spare Key Spare Keylock with Keys EOL Backbox (Canadian applications only) Battery Harness Part Number 84-732001-001 84-732001-201 06-220023-001 76-600000-007 06-220175-001 76-100010-001 06-236716-001 06-236727-001 06-220148-002 06-236719-002 06-220149-001 06-220172-002 06-220174-002 06-220176-001 06-220150-001 06-118394-002 06-220151-001 06-118013-001 06-129924-001 06-129963-002 06-129925-002 *For Canadian applications.Optional door with Manual Release and Abort switches . operating instruction sheet.NEMA 1 rated 18 gauge sheet steel with door . D x 19 in.Indoor/Dry use only . battery leads. H (362 mm x 152 mm x 483 mm) • Environmental Criteria . INC. Inc. operation. MA 01721. The product must be properly applied to work correctly.com .Kidde is a registered trademark of Kidde-Fenwal. Telephone: (508) 881-2000. or if you have a particular problem or question.2000 Fax: 508. AEGIS and Gemini are trademarks of Kidde-Fenwal. MA 01721 Ph: 508.881. and Maintenance Manual P/N 06-236716-001. FE-13 is a registered trademark of DuPont.. Ashland. INC. For detailed installation. refer to the Kidde AEGIS Conventional Fire Alarm-Suppression Conventional Unit Installation.kiddefiresystems. contact KIDDE-FENWAL. KIDDE-FENWAL. FM-200 is a registered trademark of Chemtura. and configuration information. ArgoniteTM is a registered trademark of Ginge Kerr. Operation. assumes no responsibility for the product’s suitability for a particular application. 3MTM NovecTM 1230 Fire Protection Fluid is a trademark of 3M. This literature is provided for informational purposes only. Inc.8920 www. If you need more information on this product. K-84-100 Rev AC © 2007 Kidde-Fenwal Inc.881. Printed in USA A UTC Fire & Security Company 400 Main Street Ashland. Two red Light Emitting Diodes (LEDs) are located diametrically opposite each other so as to allow 360degree viewing. respectively. low-voltage. The Model CPD-7054D is also suitable for duct housing applications in air velocities from 500 to 4000 fpm. The Fenwal 732 has three detection circuits which can support up to 25 detectors per circuit. A fine mesh insect screen protects the chamber area and is used to avoid potential nuisance alarms. During standby. Table 1 lists the Technical Specifications for Models CPD7054 and CPD-7054D Ionization Smoke Detectors. . The Detectors are designed for open area/ duct housing applications per UL268/UL268A and may be installed in systems intended for Releasing Device Service through use of compatible Fire Alarm Control Panels. Obscuration Sensitivity Measurement/Testing • Wireless Measurement in %/ft. both LEDs light steady at full brilliance. A locking feature is provided for vandal resistant security. The characteristic 360-degree detector design permits smoke entry from any direction. Special signal processing techniques verify the presence of smoke before the detector will alarm. During alarm. Both models are compatible with the Fenwal 732 control unit. Both LEDs continuously indicate the operating condition of the Detector. A unique sensing chamber design permits the operation of the Models CPD-7054 and CPD-7054D in open areas with air velocities from 0 to 300 fpm and 0 to 500 fpm.8 Vdc Low Current Design Dual Response LEDs Allow 360-degree Viewing Trouble Indication Low Profile Appearance Using Surface Mount Technology Electrically and Mechanically Compatible with all Fenwal Smoke and Electronic Heat Detectors and Bases Interchangeable 2-Wire and 4-Wire Bases Universal Relay Modules Non Polarized Locking Feature for Vandal Resistance Fine Mesh Insect Screen EMI and RFI Resistant A UTC Fire & Security Company Effective: September 2008 70-01 • • • • • • • • • • • • • • • DESCRIPTION The Advance Models CPD-7054 & CPD-7054D are dual chamber Ionization Smoke Detectors designed to sense both visible and invisible products of combustion.2 to 36. Obscuration • Remote and Local Functional Test Capability Wide Range of Input Voltage 10. Obscuration • CPD-7054D: 1. The Detectors have advanced solid-state.00% per ft. The detector head is installed into its mounting base with a simple twist-lock action. the LEDs flash once every six seconds. surface-mount circuitry and are designed for 2-Wire and 4-Wire installation using the appropriate Detector base. A double flash every six seconds indicates a detector with a sensitivity threshold outside acceptable limits.30% per ft. CONTROL UNITS The Models CPD-7054 and CPD-7054D Detectors are designed to operate with control units and releasing devices having specific voltage and current characteristics that are compatible with the detector circuitry.Advanced Ionization Smoke Detectors Models CPD-7054 and CPD-7054D FEATURES • Approvals/Listing • US and Canadian UL Listed (cULus) • FM Approved • CSFM Approved • NYC MEA Accepted Dual Ionization Chamber Technology Nominal Sensitivity • CPD-7054: 1. A unique gated output circuit design provides improved stability and transient suppression. (35 mm) 3-29/32 in. CNSC I51FE1 30 ft. USNRC.500 feet (2.5 m/s) 500 to 4000 fpm (2.30% + 0. CSFM.500 feet (2. (110g) w/o base 0 to 500 fpm (0 to 2. (110g) w/o base 35.2 (83.2 (83.10% .2 to 36.8 to 36. MEA-NYC.1 m) centers or 900 ft.5 m/s) N/A Up to 7.Table 1: Technical Specification Model Number Part Number Detection Approvals UL Compatibility I. flame-retardant plastic.0.8 16.3 oz.1 m) centers or 900 ft. flame-retardant plastic.5 to 20 m/s) Up to 7.8 CPD-7054D 70-540000-002 Dual Ionization Chamber cULus. (11 mm) 5-29/32 in.25% .8 16. CNSC I51FE1 30 ft. (9.8 to 36. off white 35.12% per foot Obscuration 10. FM.286 m) High-impact. (150 mm) 0 to 300 fpm (0 to 1. (99 mm) 3/64 in. Listed Spacing Radioactive Source Material Activity Nominal Sensitivity Standby Voltage (Vdc) Using 2WB: Using 4WRB: Maximum Current Standby: Alarm: Response Indicators Quantity: Standby Condition: Thermistor Trouble: Alarm Condition: Operating Environment Operating Temperature: Storage Temperature: Relative Humidity: Air Velocity Open Area: Duct Housing: Altitude: Physical Characteristics Material and Finish: Weight: Dimensions Detector Height: Detector Diameter: Base Height: Base Diameter: 1-3/8 in.6 kBq 1.3 oz. (99 mm) 3/64 in.D. (150 mm) 1-3/8 in.286 m) High-impact. (35 mm) 3-29/32 in.0.6 m2) Americium 241 (sealed) 0.6 kBq) 1.8 µCi (29.8 µCi (29. (11 mm) 5-29/32 in.2 to 36.6 m2) Americium 241 (sealed) 0. USNRC. off white 70 µA 100 mA 2 external LEDs One flash every 9 seconds Double flash every 9 seconds Steady at full brilliance 32° to 120°F (0° to 49°C) -20° to 180°F (-29° to 82°C) 0 to 93% Non-condensing 70 µA 100 mA 2 external LEDs One flash every 9 seconds Double flash every 9 seconds Steady at full brilliance 32° to 120°F (0° to 49°C) -20° to 180°F (-29° to 82°C) 0 to 93% Non-condensing CPD-7054 70-540000-001 Dual Ionization Chamber cULus. MEA-NYC.42% per foot Obscuration 10.00% + 0.8 -2- . (9. CSFM. FM. A go/no-go test can be performed using a test magnet. Part 10 (10CFR).6 kBq). Cleaning programs should be geared to the individual environment in conformance with NFPA 72. 3-1/2-inch and 4-inch octagonal. 102 mm octagonal. SPACING (OPEN AREA LOCATION) The Models CPD-7054 and CPD-7054D Detectors are listed to be installed on maximum 30 ft. conversely. For additional information. etc. Various base options are available to provide auxiliary relay and/or remote indication and remote test feature. No field repair should therefore be attempted. (0.and 4-wire bases. near fireplaces or furnace rooms and within three (3) ft. Computer rooms and other such installations may require spacing with a maximum of 200 ft.20. -3- . 89 mm.The Fenwal Models CPD-7054 and CPD7054D Ionization Smoke Detectors shall have two Red LEDs located diametrically opposite each other so as to TESTING AND MAINTENANCE Testing shall be performed upon installation of the detector and once a year thereafter as stated in NFPA-72 latest edition. The recommended requirement for detector maintenance consists of an annual cleaning of dust from the detector head by using the suction of a vacuum cleaner. Detector sensitivity shall be checked within one year of installation and every alternative year thereafter as stated in NFPA 72. Refer Fenwal Document 06-235056-001 for additional details.9 m) of air supply ducts or air diffusers. CAUTION Do not attempt disassembly of the factory sealed smoke detector. Ionization Smoke Detectors containing a radioactive source of strength greater than 0. any person receiving. For service. consult the Fenwal Automatic Fire Detection Application Engineering Manual MC-402. The combination detector head and twist-lock base shall be UL Listed compatible with a UL Listed fire alarm control unit.6 m2) due to high air exchange rates. UL268/UL268A listed dual-chamber. This assembly is sealed for your protection and should not be opened for servicing. Resultant maximum 900 square foot (83. etc. The Models CPD-7054 and CPD-7054D Ionization Smoke Detectors shall share interchangeable bases with the PSD-7157 and PSD-7157D Photoelectric Smoke Detectors and the THD-7052 and THD-7053 Heat Detectors. exempts them from a specific license. Opening of the detector will void its warranty. Paragraph 30. Under the Code of Federal Regulations. RADIOACTIVE MATERIAL/DISPOSAL The Americium 241 radioactive material used is shielded by a stainless steel housing and has a maximum activity of 0. INSTALLATION Detector bases are directly mounted on the electrical junction boxes (3-inch.8 microcuries (29. by-product material in detectors designed to protect life or property from fires or airborne hazards is automatically granted a general license which. kitchen areas. Refer Fenwal Documents 06-236514-001 and 06-235056-001 for details on using the Infrared Wireless Sensitivity Tester Model DST-003. high air exchange rates.6 kBq) shall not be acceptable. without removing the detector from its base. (4.1 m) centers.). using. Fenwal Models CPD-7054 and CPD-7054D. 76 mm round or 102 mm2) without the need for any mechanical adapter required.. NFPA-72 and the local Authority Having Jurisdiction. please refer Fenwal Document 06-235056-001.8 microcuries (29. The United States Nuclear Regulatory Commission (USNRC) allows the user of Americium 241 filled smoke detectors to dispose of them without obtaining a license. return detector head intact to Fenwal. (9. The Model CPD-7054 and CPD-7054D Ionization Smoke Detectors may be interchanged with other Fenwal Series THD-705X Electronic Heat Detector and Series PSD715X Photoelectric Smoke Detectors when using multifunction base configuration.2 (18.6 m2) spacing may be used as a reasonable guide for comparable applications. Ionization Smoke Detectors.DETECTOR BASE OPTIONS The Models CPD-7054 and CPD-7054D can be used with the detector base options and accessories in Table 2. ARCHITECT/ENGINEER SPECIFICATIONS The contractor shall furnish and install where indicated on the plans. The tester provides direct readout in percent per foot obscuration from a distance of 15 ft.6 m) high and will operate with minimum air circulation. owning. WIRING DIAGRAMS For detailed wiring diagrams with Fenwal 2. 3-inch round or 4-inch2) (76 mm. Where special conditions exist (ceiling obstructions. Detectors should not be located in areas with excessive exhaust fumes. typically on smooth ceilings up to 15 ft. reduced spacing must be used to achieve adequate protection. SPARE PARTS The Models CPD-7054 and CPD-7054D Detectors are factory repairable only and have no field serviceable spare parts. thereby allowing them to both receive and dispose of smoke detectors without returning to the manufacturer. The vandal-resistant security locking feature shall be used in those areas as indicated on the drawings. and/or remote LED alarm indicators shall be installed where indicated. The detector may be reset by actuating the control panel reset switch.8 Vdc. (4. Voltage and RF transient suppression techniques to withstand up to 20 volt/meter shall be employed to minimize susceptibility to false alarms.allow 360-degree viewing. Measurement shall be accomplished with a wireless infrared Fenwal Sensitivity Tester (DST-003) allowing direct measurement in percent per foot obscuration. It shall also be possible to perform a functional test of the detector without the need for generating smoke. The Fenwal Models CPD-7054 and CPD-7054D Ionization Smoke Detectors shall operate over an input voltage range from 10. It shall be possible to measure the sensitivity of the Fenwal Models CPD-7054 and CPD-7054D Ionization Smoke Detectors from a distance of up to 15 ft. both LEDs shall light steady at full brilliance. the LEDs shall double flash every six seconds.6 m) without removal from the base.2 to 36. During alarm. Supplementary SPDT relays. During standby. remote test. the LEDs shall flash once every six seconds. If the sensitivity of the detector drifts outside acceptable limits. The locking feature shall be field removable when not required. Sensitivity measurement techniques requiring wiring between the Detector-Base combination and the Tester shall not be acceptable. The LEDs shall continuously indicate the operating condition of the Detector. -4- . Spare SPDT Relay for 2WRB Bases. Remote LED & Test capabilities. (CID = MAFE1) -5- .5 A. 125 Vac. 30 Vdc/0. Minimum Alarm Current 15 mA @ 24 Vdc. Minimum Alarm Current 35 mA @ 24 Vdc. (CID = FE55A) 4-Wire Base w/ 4WRM. THD-7052 THD-7053 135°F (57°C) Fixed Heat Detector.Table 2: Ordering Information Part Number Model Description Detector Heads . Connects to circuit via pigtail leads. -002. Allows CPD-705X and PSD-715X Detectors to physically connect to Base P/Ns 70-201000-001. Remote LED & Test capabilities. (CID = FE52A) 2-Wire Base w/ 2WRM. Minimum Alarm Current 19 mA @ 24 Vdc.Heat 70-520000-001 70-530000-001 Detector Bases 70-501000-001 70-501000-002 2-Wire 2WRLT 2-Wire Standard Base. -005 & DH-22.Photoelectric Smoke 71-570000-001 71-570000-002 Detector Heads . Connects to circuit via pigtail leads. -003. Contacts rated 1. Connects to circuit via screw terminals. Connects to circuit via screw terminals. (CID = FE51A) 2-Wire Base w/ Remote LED & Test capabilities. 15°F (-9°C) Rate of Rise (cULus) 135°F (57°C) Fixed Heat Detector (cULus) PSD-7157 PSD-7157D Photoelectric Advanced Smoke Detector (cULus) Photoelectric Advanced Smoke Detector (cULus) 70-501000-005 2WRB 70-501000-101 4WRB 70-500000-004 Detector Accessories 06-117883-001 29-116788-001 70-200000-911 70-200000-914 70-500000-003 70-501000-003 2WRM Test Magnet EOL Supervisory Relay RA-911 RA-914 DST-003 MA-001 Remote Alarm Indicator Remote Alarm Indicator with Smoke Detector Switch Advanced Handheld Wireless Smoke Detector Sensitivity Tester Mechanical Retrofit Adapter.0 A.Ionization Smoke 70-540000-001 70-540000-002 CPD-7054 CPD-7054D Ionization Advanced Smoke Detector (cULus) Ionization Advanced Smoke Detector (cULus) Detector Heads . kiddefiresystems.881. If you need more information on this product. Ashland. INC. 70-01 Rev AD © 2008 Kidde-Fenwal Inc.. MA 01721.881.2000 Fax: 508. MA 01721 Ph: 508. assumes no responsibility for the product’s suitability for a particular application.com . The product must be properly applied to work correctly. contact KIDDE-FENWAL.8920 www. INC. Printed in USA A UTC Fire & Security Company 400 Main Street Ashland. or if you have a particular problem or question. KIDDE-FENWAL. Telephone: (508) 881-2000.This literature is provided for informational purposes only. 25% per ft.8 Vdc Low Current Design Dual Response LEDs Allow 360-degree Viewing Trouble Indication Low Profile Appearance Using Surface Mount Technology Electrically and Mechanically Compatible with all Fenwal Smoke and Electronic Heat Detectors and Bases Interchangeable 2-Wire and 4-Wire Bases Universal Relay Modules Non Polarized Locking Feature for Vandal Resistance Fine Mesh Insect Screen EMI and RFI Resistant A UTC Fire & Security Company Effective: September 2008 70-02 • • • • • • • • • • • • • • DESCRIPTION The Advance Models of PSD-7157 and PSD-7157D Photoelectric Smoke Detectors respond to a broad spectrum of both flaming and smoldering fire conditions.Advanced Photoelectric Smoke Detectors Models PSD-7157 and PSD-7157D FEATURES • Approvals/Listing • US and Canadian UL Listed (cULus) • FM Approved • CSFM Approved • NYC MEA Accepted Nominal Sensitivity • PSD-7157: 3. Obscuration • PSD-7157D: 2. The Detectors have advanced solid-state. A double flash every six seconds indicates a detector with a sensitivity threshold outside acceptable limits. Obscuration • Remote and Local Functional Test Capability Wide Range of Input Voltage 10. both LEDs light steady at full brilliance. The detector head is installed into the base with a simple twist-lock action. . A unique sensing chamber design permits the operation of the Models PSD-7157 and PSD-7157D in open areas with air velocities from 0 to 300 fpm and 0 to 4000 fpm respectively. During alarm. A unique gated output circuit design provides improved stability and transient suppression. A fine mesh insect screen protects the chamber area and is used to avoid potential nuisance alarms. The Fenwal 732 has three detection circuits which can support up to 26 detectors per circuit. The characteristic 360-degree detector design permits smoke entry from any direction. surface-mount circuitry and are designed for 2-Wire and 4-Wire installation using the appropriate Detector base. the LEDs flash once every six seconds. Table 1 lists the Technical Specifications for Models PSD7157 and PSD-7157D Photoelectric Smoke Detectors. During standby. Two Red Light Emitting Diodes are located diametrically opposite each other so as to allow 360-degree viewing.40% per ft. Special signal processing techniques verify the presence of smoke before the detector will alarm. The Detectors are compatible with the Fenwal 732 control unit. The Model PSD-7157D is also suitable for duct housing applications in air velocities from 500 to 4000 fpm. CONTROL UNITS The Models PSD-7157 and PSD-7157D Detectors are designed for operation with control units and releasing devices having specific voltage and current characteristics that are compatible with the detector circuitry. low-voltage. Obscuration Sensitivity Measurement/Testing • Wireless Measurement in %/ft. The Detectors are designed for open area/ duct housing applications per UL268/UL268A and may be installed in systems intended for Releasing Device Service through use of compatible Fire Alarm Control Panels. Both LEDs continuously indicate the operating condition of the Detector.2 to 36. A locking feature is provided for vandal resistant security. 04% . CSFM. (99 mm) 3/64 in. The Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors may be interchanged with other Fenwal Series THD-705X Electronic Heat Detectors and Series CPD-705X Ionization Smoke Detectors when using multifunction base configuration. (9. Various base options are available to provide auxiliary relay and/or remote indication and remote test feature.8 to 36.34% per foot Obscuration 10.2 (83. off white 35.6 m2) 2. (9.1.8 16.40% + 0.286 m) High-impact. FM. MEA-NYC P55FE1 30 ft. (11 mm) 5-29/32 in. (99 mm) 3/64 in. (150 mm) 0 to 300 fpm (0 to 1. flame-retardant plastic.1.45% .500 feet (2.78% per foot Obscuration 10.1 m) centers or 900 ft.D. Listed Spacing Nominal Sensitivity Standby Voltage (Vdc) Using 2WB: Using 4WRB: Maximum Current Standby: Alarm: Response Indicators Quantity: Standby Condition: Thermistor Trouble: Alarm Condition: Operating Environment Operating Temperature: Storage Temperature: Relative Humidity: Air Velocity Open Area: Duct Housing: Altitude: Physical Characteristics Material and Finish: Weight: Dimensions Detector Height: Detector Diameter: Base Height: Base Diameter: 1-3/8 in.500 feet (2. CSFM.286 m) High-impact.8 to 36.25% + 0. FM. (35 mm) 3-29/32 in. (35 mm) 3-29/32 in.1 m) centers or 900 ft.2 (83.8 PSD-7157D 71-570000-002 Photoelectric cULus. (110g) w/o base 0 to 4000 fpm (0 to 20 m/s) 500 to 4000 fpm (2. (150 mm) 1-3/8 in. MEA-NYC P55FE1 30 ft.5 m/s) N/A Up to 7.2 to 36.8 DETECTOR BASE OPTIONS The Models PSD-7157 and PSD-7157D can be used with the detector base options and accessories in Tables 2. (11 mm) 5-29/32 in.6 m2) 3.Table 1: Technical Specification Model Number Part Number Detection Approvals UL Compatibility I.3 oz.3 oz. off white 35.2 to 36.8 16.5 to 20 m/s) Up to 7. flame-retardant plastic. -2- . (110g) w/o base 70 µA 100 mA 2 external LEDs One flash every 11 seconds Double flash every 11 seconds Steady at full brilliance 32° to 120°F (0° to 49°C) -20° to 180°F (-29° to 82°C) 0 to 93% Non-condensing 70 µA 100 mA 2 external LEDs One flash every 11 seconds Double flash every 11 seconds Steady at full brilliance 32° to 120°F (0° to 49°C) -20° to 180°F (-29° to 82°C) 0 to 93% Non-condensing PSD-7157 71-570000-001 Photoelectric cULus. both LEDs shall light steady at full brilliance. For additional information.6 m) without removal from the base. Computer rooms and other such installations may require spacing with a maximum of 200 ft. typically on smooth ceilings up to 15 ft. The tester provides direct readout in percent per foot obscuration from a distance of 15 ft. Detector sensitivity shall be checked within one year of installation and every alternative year thereafter as stated in NFPA 72. consult the Fenwal Automatic Fire Detection Application Engineering Manual MC-402. 3-1/2-inch and 4-inch octagonal. The LEDs shall continuously indicate the operating condition of the Detector. reduced spacing must be used to achieve adequate protection. -3- . NFPA-72 and the local Authority Having Jurisdiction. Sensitivity measurement techniques requiring wiring between the Detector-Base combination and the Tester shall not be acceptable. During standby. Measurement shall be accomplished with a wireless infrared Fenwal Sensitivity Tester (DST-003) allowing direct measurement in percent per foot obscuration.2 (18.104 INSTALLATION Detector bases are directly mounted on the electrical junction boxes (3-inch. etc. return detector head intact to Fenwal. The Fenwal Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors shall have two Red LEDs located diametrically opposite each other so as to allow 360-degree viewing. 76 mm round or 102 mm square) without the need for any mechanical adapter required. (9. (. near fireplaces or furnace rooms and within three (3) ft. It shall also be possible to perform a functional test of the detector without the need for generating smoke. The detector bases also include a locking feature that prevents removal of the detector without use of a tool. kitchen areas. The combination detector head and twist-lock base shall be UL Listed compatible with a UL Listed fire alarm control unit. The locking feature shall be field removable when not required. The Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors shall share interchangeable bases with the CPD-7054 and CPD7054D Ionization Smoke Detectors and the THD-7052 and THD-7053 Heat Detectors. Fenwal Models PSD-7157 and PSD-7157D. SPARE PARTS The Models PSD-7157 and PSD-7157D Detectors are factory repairable only and have no field serviceable spare parts. Cleaning programs should be geared to the individual environment in conformance with NFPA 72.SPACING (OPEN AREA LOCATION) The Models PSD-7157 and PSD-7157D Detectors are listed to be installed on maximum 30 ft. 102 mm octagonal. please refer Fenwal Document 70. (4. 3-inch round or 4-inch square) (76 mm.6 m ) spacing may be used as a reasonable guide for comparable applications. UL268/UL268A listed Photoelectric Smoke Detectors. No field repair should therefore be attempted. The recommended requirement for detector maintenance consists of an annual cleaning of dust from the detector head by using the suction of a vacuum cleaner. Where special conditions exist (ceiling obstructions. Resultant maximum 900 square foot (83. TESTING AND MAINTENANCE Testing shall be performed upon installation of the detector and once a year thereafter as stated in NFPA-72 latest edition. This assembly is sealed for your protection and should not be opened for servicing. high air exchange rates.). For service. without removing the detector from its base. WIRING DIAGRAMS For detailed wiring diagrams with Fenwal 2. Refer Fenwal Document 06-235056-001 for additional details. 2 CAUTION Do not attempt disassembly of the factory sealed smoke detector. the LEDs shall double flash every six seconds. Opening of the detector will void its warranty.9 m) of air supply ducts or air diffusers.6 m) high and will operate with minimum air circulation. A go/no-go test can be performed using a test magnet. ARCHITECT/ENGINEER SPECIFICATIONS The contractor shall furnish and install where indicated on the plans. If the sensitivity of the detector drifts outside acceptable limits. During alarm. 89 mm. Refer Fenwal Documents 06-236524-001 and 06-235056-001 for details on using the Infrared Wireless Sensitivity Tester Model DST-003.6 m2) due to high air exchange rates. the LEDs shall flash once every six seconds. The vandal-resistant security locking feature shall be used in those areas as indicated on the drawings.1 m) centers. Detectors should not be located in areas with excessive exhaust fumes. The detector may be reset by actuating the control panel reset switch.and 4-wire bases. It shall be possible to measure the sensitivity of the Fenwal Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors from a distance of up to 15 feet (4. 30 Vdc/0.881. Minimum Alarm Current 15 mA @ 24 Vdc. assumes no responsibility for the product’s suitability for a particular application.Photoelectric Smoke 71-570000-001 71-570000-002 Detector Heads . remote test. (CID = FE52A) 2-Wire Base w/ 2WRM. Printed in USA A UTC Fire & Security Company 400 Main Street Ashland. Allows CPD-705X and PSD-715X Detectors to physically connect to Base P/Ns 70-201000-001.Ionization Smoke 70-540000-001 70-540000-002 CPD-7054 CPD-7054D Ionization Advanced Smoke Detector (cULus) Ionization Advanced Smoke Detector (cULus) Detector Heads . and/or remote LED alarm indicators shall be installed where indicated .8920 www. Remote LED & Test capabilities. Minimum Alarm Current 35 mA @ 24 Vdc.8 Vdc. Telephone: (508) 881-2000.0 A. Connects to circuit via pigtail leads.2 to 36.2000 Fax: 508. Spare SPDT Relay for 2WRB Bases. Connects to circuit via screw terminals. The product must be properly applied to work correctly. KIDDE-FENWAL. 125 Vac.881. Connects to circuit via pigtail leads. Ashland.Heat 70-520000-001 70-530000-001 Detector Bases 70-501000-001 70-501000-002 2-Wire 2WRLT 2-Wire Standard Base. -003. (CID = MAFE1) This literature is provided for informational purposes only. 70-02 Rev AE © 2008 Kidde-Fenwal Inc.kiddefiresystems. Table 2: Ordering Information Part Number Model Description Detector Heads . Supplementary SPDT relays. contact KIDDE-FENWAL. Voltage and RF transient suppression techniques to withstand up to 20 volt/meter shall be employed to minimize susceptibility to false alarms. or if you have a particular problem or question. Connects to circuit via screw terminals. -002. Remote LED & Test capabilities.The Fenwal Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors shall operate over an input voltage range from 10. If you need more information on this product. -005 & DH-22. Minimum Alarm Current 19 mA @ 24 Vdc.com . (CID = FE55A) 4-Wire Base w/ 4WRM..5 A. MA 01721 Ph: 508. INC. MA 01721. INC. (CID = FE51A) 2-Wire Base w/ Remote LED & Test capabilities. 15°F (-9°C) Rate of Rise (cULus) 135°F (57°C) Fixed Heat Detector (cULus) PSD-7157 PSD-7157D Photoelectric Advanced Smoke Detector (cULus) Photoelectric Advanced Smoke Detector (cULus) 70-501000-005 2WRB 70-501000-101 4WRB 70-500000-004 Detector Accessories 06-117883-001 29-116788-001 70-200000-911 70-200000-914 70-500000-003 70-501000-003 2WRM Test Magnet EOL Supervisory Relay RA-911 RA-914 DST-003 MA-001 Remote Alarm Indicator Remote Alarm Indicator with Smoke Detector Switch Advanced Handheld Wireless Smoke Detector Sensitivity Tester Mechanical Retrofit Adapter. THD-7052 THD-7053 135°F (57°C) Fixed Heat Detector. Contacts rated 1.
Copyright © 2024 DOKUMEN.SITE Inc.