Keyence LK

May 24, 2018 | Author: ramjoce | Category: Lens (Optics), Mirror, Reflection (Physics), Laser, Pixel


Comments



Description

Ultra High-Speed/High-AccuracyLaser Displacement Sensor LK-G5000 Series TRANSPARENT/MIRROR TARGETS COARSE TARGETS FINE TARGETS Ability to respond to any situation, reliability stemming from high performance Highest repeatability in it s class Highest accuracy in its class Fastest in the world 0.005µm ±0.02% 392kHz COARSE TARGETS W I D E S P OT T Y P E WIDE SPOT Reference Distance & Repeatability TYPE Measurement Range 8±0.5 mm LK-H008W 0.005 μm 0.32" ± 0.02" 20±3 mm LK-H027 0.02 μm 0.79" ± 0.12" 50±10 mm LK-H057 0.025 μm 1.97" ± 0.39" 80±18 mm LK-H087 0.1 μm 3.15" ± 0.71" 150±40 mm LK-H157 0.25 μm 5.91" ± 1.57" FINE TARGETS F O CU S ED S P OT T Y P E FOCUSED Reference Distance & Repeatability SPOT TYPE Measurement Range 8±0.5 mm LK-H008 0.005 μm 0.32" ± 0.02" 20±3 mm LK-H022 0.02 μm 0.79" ± 0.12" 50±10 mm LK-H052 0.025 μm 1.97" ± 0.39" 80±18 mm LK-H082 0.1 μm 3.15" ± 0.71" 150±40 mm LK-H152 0.25 μm 5.91" ± 1.57" 2 LK- G5000 Series 69"/+0.56"/+0.5 -39. accuracy.8 mm LK-H027K 0. LK.025 μm 1.02 μm 0.20" LK-H087 76.1±2.005 µm The need to improve product quality makes high performance critical.63" ± 0.02" -0.7 -17. The LK-G5000 Series provides the highest repeatability in its class and is highly capable in any application.25 μm & LK-F2 5.81" -1. Highest Accuracy in its Class ± 0. Fastest in the World 392 kHz The world's fastest sampling rate not only captures displacement of moving or rotating targets. the series provides high performance with the high accuracy that is increasingly required.3±5.5 mm 0.6 mm/+14. surface conditions… TRANSPARENT/MIRROR TARGETS The LK-G5000 Series offers head choices that S P E CU L A R R EFL E C T I O N T Y P E provide stable measurements on any target SPECULAR Reference Distance & Repeatability REFLECTION TYPE Measurement Range 8±0. and the capability to provide excellent performance in any application.G5000 Series 3 . but also increases stability in all manner of applications.96" Laser displacement sensors need speed. Highest Repeatability in its Class 0. In order to become the world's best in every aspect.11" 46.4 mm 0.57" LK-H157 147.Color.005 μm 0.5 mm LK-H008 ( W ) 0. materials.02 % High-linearity enhances the LK-G5000's capabilities.02" 16. By taking advantage of new technology.82" ± 0.32" ± 0.5 mm /+24.2 mm LK-H057K 0.1 μm & LK-F3 3. the LK-G5000 is built with the latest cutting-edge technology. tightly focus the laser spot while eliminating Delta cut technology any beam irregularities. is used to achieve unparalleled accuracy. resulting in light intensity adjustments even more sensitive than before. the position of the target the light-receiving can be calculated by determining the location of the reflected element beam spot on the RS-CMOS.02% has been achieved. possible from the RS-CMOS. Further. when combined with the redesigned the performance of this This lens is designed to displacement sensor. double the number of pixels. Cylindrical lens LK-H087 Double pixel HDE lens This lens forms a highly regular oval number A combination lens that has achieved Measuring range spot that is critical for the accurate measurement of rough targets.G5000 Series . RS-CMOS R = HIGH-RESOLUTION S = HIGH-SPEED High-accuracy has been achieved by doubling the pixel width and doubling the number of pixels in the CMOS.S. MEASUREMENT PRINCIPLE HDE Lenses & Delta Cut Technology The newly developed HDE lens minimizes the effect of distortion of the spot on the light-receiving element. thanks to delta cut technology maintaining the symmetry of the beam spot. Designed to optimize the spot geometry on the pixel. Given the known relative positions of the filter causes the lens Light-receiving loss of symmetry on filter laser emitter and the RS-CMOS detector. The resolution of light-emmision time has been further refined. This is critical for the By symmetrically positioning Conventional RS-CMOS the CMOS element. CMOS. linearity of 0. the effects size is very consistent. Double pixel width measurement of minute receiving lens and light- targets as the beam spot receiving filter. This optimal beam Linear collimator lens CMOS designed to maximize spot geometry. the minimization of distortion effects. A custom small height on the receiving element. No symmetry with the RS-CMOS Symmetry with the RS-CMOS 4 LK. Technology that has achieved ABLE II Light intensity adjustment unparalleled accuracy engine. Target Without DELTA CUT With DELTA CUT RS-CMOS The focal point RS-CMOS Focal point is out of place is sharp The fundamental measurement principle of the LK-G5000 Series The light-receiving High-accuracy HDE is based on triangulation. light. of optical distortions are minimized. but to maintain the Double the pixel width. a F. Conventional In addition the spot width is kept The lens is specially designed to very consistent throughout the bring out the maximum performance measurement range. The optical system has been redesigned not only to RS-CMOS increase the width of the beam spot. By synthesizing surface surface surface surface surface surface the wave patterns. laser power. Received-light wave pattern Detecting the real peak *RPD=Real Peak Detect Penetrated light Unable to measure the Cancels the difused light. from the mirror surface. High accuracy is achieved because the (lower surface) measurement is not affected by each layer's reflectivity. LK. The R PD algorithm is able to detect the Real Peak by canceling the impact of the broadened wave patterns. and gain. highly accurate measurements Optimized wave form Optimized wave form Optimized wave form with insufficient light or saturation are possible. Furthermore. glass/mirror surfaces Saturation Synthesized level wave pattern Optimizes light-intensity control by sensing the Glass Mirror Glass Mirror Glass Mirror reflective light from each layer. Translucent object real peak due to the difused light. ABLE II Laser power High ABLE II has a high-speed tracking ability that is eight times faster than conventional models.G5000 Series 5 . Laser power Low Emission time Short Emission time repeatability Emission Long High time Proper Intensity Low Board height measurement Translucent Object (RPD* ALGORITHM) A translucent object causes a diffuse reflection beneath the surface when the laser beam penetrates inside the object and the received-light wave pattern gently broadens. Measurement of the height/thickness of the mirror glass Transparent Object (MULTI -ABLE CONTROL) Glass surface 1 Optimizes the laser intensity by sensing and adjusting (upper surface) to the reflected light for each layer of a transparent Mirror surface 2 object.Sophisticated measurement ability to excel in any situation Active Balanced Laser Control Engine ABLE II Version II The shift of laser emission time and laser power with target reflectance Mirrored surface Black rubber Better than Higher than Superior to High Reflectance Low the conventional model the conventional model the conventional model 3x 4x 8x Conventional model Dynamic Range Resolution of High-Speed Emission time too short Emission time too long Laser Emission Time Tracking Capability Too little laser power The well-established ABLE control is now even more High Proper powerful. ABLE II intelligently optimizes the RS-CMOS Low Intensity capability by balancing the three elements of laser Reflectance tracking speed affects measurement accuracy emission time. 1 Optimizing the light-intensity 2 Optimizing the light-intensity Synthesizing the optimized control of the reflective light control of the reflective light wave pattern of the from the glass surface. 001969" × 0.021654" 0. Conventional Measurement of a brushed metal surface. COARSE TARGETS Stable measurement on coarse targets W I D E S P OT T Y P E Surfaces that may appear flat. By using a sensor head with a wide beam spot.165354" 2x wider than conventional model Due to the advanced cylindrical lensing used in the LK-G5000 Series.000787" × 0. the effect of the uneven surface is averaged and stable measurements of even coarse targets are possible.004724" × 0. This microscopic surface roughness can often cause measurement errors with conventional focused spot sensors.002756" × 0. Minimizes the influence of the roughness of a coarse target surface. Never before seen measurement LK-H087 accuracy has now been achieved.055118" 0. A P P L I C AT I O N Measurement of electrode thickness Measurement of the disc-rotor vibration Position control of an air knife 6 LK.098425" 0.078740" 0.000984" × 0. Conventional LK-H087 2x the averaging Semiconductor Semiconductor result laser laser 2x Cylindrical lens Cylindrical lens RS-CMOS Cylindrical lens S P OT D I A M E T E R LK-H008W LK-H027 LK-H057 LK-H087 LK-H157 20 × 550 μm 25 × 1400 μm 50 × 2000 μm 70 × 2500 μm 120 × 4200 μm 0. including that of brushed metal surfaces and rubber surfaces. This allows the averaging area to stay consistent even if the target is moved closer to or further from the sensor head. the wide axis of the beam spot is kept very consistent throughout the measurement Measurement of metal surfaces range.G5000 Series . once magnified will often contain minute projections and depressions. This allows high precision profile -0.5 -1 -0. Profile measurement of a metal pin-gage Product of equal range LK-H022 Unit: mm Unit: mm 6 6 —Product of equal range — — — — — Target shape —LK-H022 5 5 Measured value Measured value 4 4 RS-CMOS 3 3 2 2 Linear collimator lens 1 1 0 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 -5 -4 -3 -2 -1 0 1 2 3 4 5 Position Position S P OT D I A M E T E R LK-H008 LK-H022 LK-H052 LK-H082 LK-H152 ø25μm ø20 μm ø25 μm ø50 μm ø70 μm ø120 μm ø0.004724" Unit: mm 0.G5000 Series 7 .2 Measurement of the IC pin height -2.5 measurements that were not previously possible.000984" (LK-H022) can measure any target.1 on the RS-CMOS.001969" ø0. Position A P P L I C AT I O N Active layer measurement of solar modules Zoom lens assembly accuracy Measurement of connector height LK. it is also very precisely focused on the target area.5 0 0. the influence of 0 the distortion caused by the optical filter has been minimized.5 2 2.5 1 1.000787" ø0.5 -2 -1.1 Measured value Thanks to delta cut technology. with the highest level of accuracy in the industry. from fine components to profile measurements.000984" ø0. This and other improvements in the optical system mean that not only is the beam spot focused -0. FINE TARGETS Optimal for fine or profile measurements F O CU S ED S P OT T Y P E The smallest spot diameter in its class of ø25 µm ø0.000984" ø0.002756" ø0.2 —LK-H022 — Conventional product Measurement of the IC pin height 0. 10 Linearity (%of F.001969" × 0.) Linearity (%of F.S. -2 -4 -6 Measurement of the touch panel -8 —OUT2 Surface height -10 surface height and air gap.098425" 0.002756" ø0.02 0.001969" ø0.078740" 0.000787" ø0.G5000 Series . TRANSPARENT/MIRROR TARGETS Transparent/mirror surface measurement result demonstration S P ECU L A R R EFL EC T I O N T Y P E The LK-G5000 Series incudes a group of heads specifically designed for use on highly reflective targets such as glass or other mirror surfaces.055118" 0.05 0.S. By further improving the 8 6 Measurement of the touch panel surface height 4 functionality of the receiver element.02 -0. 0 2 4 6 8 10 Position [mm] A P P L I C AT I O N Step measurement between the HDD reader Measurements of glass board thickness.004724" × 0.000984" × 0.) 0.20” RS-CMOS —Sample1 —Sample2 —Sample3 —Sample4 —Sample5 S P OT D I A M E T E R ( W I D E T Y P E ) HDE Lens LK-H008W LK-H027K LK-H057K LK-H087+LK-F3 LK-H157+LK-F2 20 × 550 μm 25 × 1400 μm 50 × 2000 μm 70 × 2500 μm 120 × 4200μm 0.00 -0.20” 0 Stroke distance [mm inch ] 5 0. stable measurements 2 0 of 20 µm 0.10 0 Stroke distance [mm inch ] 5 0. Conventional LK-H052K 0.05 -0.00 0.05 -0.05 0. These heads are available with wide or focused beam spots and are ideally suited for high accuracy measurements on such surfaces.002756" × 0.02 0.000984" ø0.10 -0.000787" × 0. Z-axis positioning of a patterned wafer arm and the media warpage and parallelism 8 LK.021654" 0.10 0.000787" gaps are now possible.02 -0.165354" S P OT D I A M E T E R ( S P OT T Y P E ) Wide/spot Both types LK-H008 LK-H022K LK-H052K LK-H082+LK-F3 LK-H152+LK-F2 available ø20 μm ø25 μm ø50 μm ø70 μm ø120μm ø0.004724" 50 48 Measurement of the touch panel surface height and air gap Gap measurement of a touch panel 46 Air gap [µm] 44 42 40 38 36 The optical system in these specialized heads has been 34 32 —OUT1 Air gap optimized to obtain the maximum resolution possible 30 10 Surface height [µm] on highly specular targets. Up to 12 heads connection LK. Furthermore. it is possible to measure simultaneously with up to 12 heads. Main controller Additional head unit Connect up to 12 sensor heads/network capable By connecting the main controller to additional head units.G5000 Series 9 . making it possible to place the system in the same network as other manufacturer's units. ST YLES Direct Control The compact controller with a built-in display can be operated directly via easy to use push buttons incorporated directly into the unit. Touch Panel Control By using the dedicated touch panel.81' away from the 3 S EL E C TA B L E operation/display units. CONTROLLER Interfacing with peripheral equipment and configuring the display style according to need is made easy Remote Control The controller can be placed up to 10 m 32. it is easy to setup and view the received light wave patterns and measured values. it is compatible with CC-Link/ DeviceNet. directly in the controller.B. Unfiltered wave pattern Wave pattern when using the average filter Displacement Speed Acceleration Vibration test of high-temperature-muffler High pass filter Captures sudden changes and removes low frequency variations. or "acceleration".. Unfiltered wave pattern Wave pattern when using the high pass filter Low pass filter Captures moderate changes while removing high frequency noise.. Measurement of Speed (m/s)..B.C.B..G5000 Series .B... "speed". thickness with each average height. enabling the user to easily set complicated calculations inside the controller that were conventionally done with PLCs or PCs.C.. it is possible to directly output or evaluate measurements that were previously calculated externally. C C A B C B pair of sensors. easily deformed.C. The LK-G5000 Series is suitable for lightweight.).) Measured value3=Z+(C+F).. Example of measurement of stage movement Movement average filter Averages the measured values to reduce high the overall noise level in the measurement. and high-temperature targets which are difficult to measure with Unfiltered wave pattern Wave pattern when using the median filter contact accelerometers. Measured value1=B-A Measured value2=B-C Measured value1=MA X(A . Standard Step Measurement Maximum/Minimum Measurement Flatness Measurement Calculates the differences Calculates the maximum Calculates the difference between a reference B and/or minimum values. The filters are user selectable for ease Just select the type of measurement: "displacement". Measured value3=A-C… Measured value2=MIN(A . A B A D D E F Measured value1=B .D..(A+C)/2… Measured value1=X+(A+D) Measured value2=Y+(B+E) Measured value1=Ave(A .)−MIN(A .. Median filter Removes any intermittent noise in the values... Unfiltered wave pattern Wave pattern when using the low pass filter 10 LK. Acceleration (m/s2) Data filter functions made easy The LK-G5000 Series is equipped with a function to directly 4 types of easy to use data processing filters are incorporated measure the speed (m/s) and acceleration (m/s 2) of targets. Pursuit of usability and new functions Convenient calculation functions Instantly calculates values based on measurements obtained by more than one head..) Warpage Measurement Multi-Point Thickness Measurement Average Height Measurement Calculates the Calculates the Calculates the amount of warpage. A C among the measurement A A C C points. Since the differential processing circuit is inside the controller.B.C. of use. between the maximum B B point and each and minimum values measuring point.) Measured value1=MA X(A ...C. In back surface addition these can be exported and easily analyzed without The easy to use menus make configuring the system simple. communication with CC-Link or DeviceNet USB Ethernet RS -232C Binar y systems is also possible through the use of an expansion unit. and correct using a simple waveform graph. This allow the sensors to be safely makes it possible to use any LK-G5000 Series sensor head with attached to robots etc. any LK-G5000 Series controller. LK. all LK-G5000 Series heads are cross-compatible. This breadth of communication methods makes it possible to always Analog I/O CC . P ER I P H ER A L EQ U I PM EN T USB / Ethernet PC RS-232C / Binary PLC etc Analog I/O PC Recorder etc Analog High-flex cables Universal sensor head compatibility High-flex cables are standard on Because individual head adjustment data is stored within the the LK-G5000 Series.Multi I/O Six different types of I/O are includes as standard on every controller.G5000 Series 11 . Furthermore. Easy configuration/analysis with a PC Easy Configuration Simplified Troubleshooting High-Capacity Data Storage Configuration menu The intensity distribution pattern for transparent glass The displacement data of a vibrating target Drop-down menu Easy to follow illustrations Received-light from the front surface Received-light from the The LK-G5000 can store 1. Mounting errors and stray laser reflections are easy to identify lengthy data processing. These cables head itself.2 million data points internally.Link DeviceNet TM have the right I/O for the job. 32" ± 0.02 µm Measurement range 0.15" 80 mm ± 18 mm 70 µm × 2500 µm LK-H087 LK-H085 98 mm 3.002756" × 0.5 mm 0.000984" Measurement range 40 mm 1.165354" 171.1 µm 3.1 mm 0.15" 98 mm 3.52" 25 µm × 1400µm Wide LK-H027K — 16.001969" LK-H087 LK-H085 59.97" 50 mm ± 10 mm ø50 µm LK-H052 LK-H050 60 mm 2.91" 0.77" 0.25 µm LK-H152 LK-H150 5.6 mm LK-H082 LK-H080 Measurement range ø70 µm Spot -0.000984" × 0.004724" Measurement range Transparent/mirror target measurement (specular reflection type) Spot type Laser Class II Laser Class IIIa Reference distance & Measurement range Repeatability Beam spot dimensions 20 µm × 550 µm Wide LK-H008W — 8 mm 0.3 mm ± 5.1 µm 3. S EN S O R H E A D L I N EU P Coarse target measurement (wide spot type) Laser Class II Laser Class IIIa Reference distance & Measurement range Repeatability Beam spot dimensions 17 mm 0.56" ø0.9 mm 6.79" ± 0.33" 150 mm 5.005 µm 0.000984" 41.12" 0.57" 50 mm 1.5mm +0.02" -17.62" 50 µm × 2000 µm Wide LK-H057K — 46.33" +14.82" ± 0.1 mm ± 2.5 mm 70 µm × 2500 µm Wide 76.67" 20 mm 0.33" 150 mm 5.97" ± 0.25 µm 5.098425" Measurement range 110 mm 4.002756" × 0.001969" × 0.91" ± 1.G5000 Series .1 mm 1.57" 0.2 mm 3.91" ± 1.5 mm 5.2 mm 0.39" 0.03" 46.025 µm 1.91" 150 mm ± 40 mm ø120 µm LK-H152 LK-H150 190 mm 7.31" 8 mm ± 0.5 mm 2.9 mm 0.57" 0.86" 80 mm ± 18 mm ø70 µm LK-H082 LK-H080 0.59" 0.7 mm 3.5 mm ø120 µm Spot Measurement range +LK-F2 +LK-F2 -1.021654" 0.57" ø0.97" 50 mm ± 10 mm 50 µm × 2000 µm LK-H057 LK-H055 60 mm 2.44" 80 mm 3.1 mm 2.055118" Measurement range 40mm 1.004724" 12 LK.004724" × 0.4 mm +LK-F2 +LK-F2 147.8 mm 0.82" 51.12" ø0.001969" × 0.078740" Measurement range 62 mm 2.078740" 0.74" 16.86" 0.098425" 91.91" 150 mm ± 40 mm 120 µm × 4200 µm LK-H157 LK-H155 190 mm 7.001969" Measurement range 62 mm 2.48" 0.79" ± 0.000984" × 0.69" +LK-F3 +LK-F3 ø0.91" 0.20" ø50 µm Spot LK-H052K — ø0.02 µm 0.48" 0.000787" 13.15" ± 0.025 µm 1.3 mm 1.055118" 0.63" 18.165354" Measurement range Fine target measurement (focused spot type) Laser Class II Laser Class IIIa Reference distance & Measurement range Repeatability Beam spot dimensions 17 mm 0.004724" × 0.25" 120 µm × 4200 µm Wide +24.63" ± 0.025 µm Measurement range 1.39" ø0.71" 0.81" 147.67" 20 mm 0.002756" LK-H157 LK-H155 108 mm 4.25 µm 5.02 µm 0.02" +LK-F3 +LK-F3 76.79" 20 mm ± 3 mm ø25 µm LK-H022 LK-H020 23 mm 0.36" 0.11" ø25 µm Spot LK-H022K — ø0.02" ø20 µm Spot LK-H008 — Measurement range ø0.7mm +0.002756" Measurement range 110 mm 4.57" 50 mm 1.79" 20 mm ± 3 mm 25 µm × 1400 µm LK-H027 LK-H025 23 mm 0.3 mm 0.71" ø0.44" 80 mm 3.97" ± 0.81" -39.15" ± 0.96" 0.1 µm 3.36" 0.000787" × 0. 57" −39.S.24") (F.= 20 mm 0.021654" ø0. Y.S.S.91" 150 mm 5.42")*6 (F.57" Red semiconductor laser Light source Wavelength 655 nm 650 nm 650 nm 650 nm 650 nm 655 nm 650 nm 655 nm 650 nm Laser IEC 60825-1 Class 1 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2 class FDA(CDRH)21CFR Part 1040.06" double amplitude in X. ±0.= 80 mm 3. and Z directions.5 mm -0. The value in parentheses is a typical example of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.02" ±3 mm ±0.15") Repeatability* 3 0.5 mm 0.S.S.S.001μm) 0.S.8mW 0.01μm) 0.11" ±2.63" 16.S.5 mm 0.24") ±0.01% of F.S.04") (F.71" ±18 mm ±0.06" double amplitude in X.002756" ø120 μm ø0.S.95mW Spot diameter (at reference distance) ø20 μm ø0. Linearity* 2 (F.02% of F.021654" 0. Y.15") Repeatability* 3 0. 240 g Approx. *2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008W) is measured in the normal measurement mode.S./°C 0.15" 150 mm 5. Linearity* 2 ±0.71" ±18 mm ±0.(F.= 80 mm 3.42") (F.04") (F.01% of F.05% of F.97" 50 mm 1.71" ±40 mm ±1.02% of F. 300g *1 Measurement range when the sampling cycle is 20 μs or more.3mW 0.= 6 mm 0.= 36 mm 1.02% of F.15") Repeatability* 3 0.55/5/10/20/50/100/200/500/1000 μs (9 steps selectable) 0.= 36 mm 1.001969" 0.001μm) 0.S.S. 2 hours respectively Material Aluminum die-cast Weight Approx.S. 280g Approx.5 mm ±0.25 μm Sampling cycle 2. *3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. ±0.098425" ø0.79" 50 mm 1.= 20 mm 0.S.02% of F.S./°C 0.055118" 0.= 80 mm 3. 1.24") (F.39" ±18 mm ±0.05% of F.02% of F.= 36 mm 1.55/5/10/20/50/100/200/500/1000 μs (9 steps selectable) 0.39" ±18 mm ±0. Linearity* 2 (F.S.165354" ±0.57" ±40 mm ±1.004724" 0.S.S.5 mm 5.001969" × 0.3mW 4. ±0.01μm) 0. mount this on a metal plate before use.7 mm 3.S. 280g Approx.S. 230g Approx.= 80 mm 3.96" Red semiconductor laser Light source Wavelength 655 nm 650 nm Laser IEC 60825-1 Class 1 Class 2 class FDA(CDRH)21CFR Part 1040. ±0.1 mm 0.01% of F.02 μm (0.01% of F.= 20 mm 0.2 mm ±0.001969" × 0.S.002756" × 0.12" ±10 mm ±0.8mW 0.63" 46.5 mm ±0.S.5 mm to +24.S.02 μm (0.02" ±2. *3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384.=1 mm 0.078740" 0.(F.10 Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II Output 0. 2 hours respectively Material Aluminum die-cast Weight Approx.025 μm 0.10 Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II Output 0.S.01% ofF.S.42") (F.57" Red semiconductor laser Light source Wavelength 655 nm 650 nm 650 nm 650 nm 650 nm 655 nm 650 nm 655 nm 650 nm Laser IEC 60825-1 Class 1 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2 class FDA(CDRH)21CFR Part 1040.71" ±40 mm ±1.02% of F. 240 g Approx.000787" × 0.(F.= 36 mm 1.S.S.95mW 4.04") (F. 230g Approx. LK.5 mm ±0.06" double amplitude in X.95mW 4.24") (F.02" ±0.15") Enclosure rating IP67 Environment resistance Incandescent lamp Ambient light Incandescent lamp or fluorescent lamp: 10000 lux max. or fluorescent lamp : 5000 lux max.S. 230g Approx.20" −17.000984" × 0.S.1 mm 0.000787" × 0.79") (F.25 μm Sampling cycle 2. ±0.S.97" 80 mm 3.S.= 6 mm 0. and Z directions.S.078740" ø0.S. *2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008) is measured in the normal measurement mode.12" ±10 mm ±0.42") (F.79" 20 mm 0.G5000 Series 13 .S. *4 When the ambient temperature rises to 40°C 104°F or more./°C 0.02" 147. fluorescent lamp : 5000 lux max. Y.= 1 mm 0. 1.000984" × 0. Please contact us for the case of specular reflection installation.=1 mm 0.95mW 4.S.82" 76.56" to +0. Ambient temperature 0 to +50°C 32 to 122˚F *4 0 to +50°C 32 to 122˚F 0 to +50°C 32 to 122˚F *4 Relative humidity 35 to 85%RH (No condensation) Vibration resistance 10 to 55 Hz./°C Temperature fluctuation (F./°C 0.S.79") (F.32" 8 mm 0.04") (F.02 μm (0.11" ±5.S.5 mm ±0.12" ±3 mm ±0.= 80 mm 3.04") ±0. 260g Approx. *4 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3.24") (F.91" Measurement range*1 ±0.= 36 mm 1.02% of F./°C 0.8mW 0. The value in parentheses is a typical example of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.01% of F.8mW 0.25μm Sampling cycle 2.04") (F.05% of F.002756" × 0./°C 0.15" 80 mm 3.S.005 μm (0.S.32" 20 mm 0. 260g Approx.= 6 mm 0.12" ±3 mm ±0. or fluorescent lamp : 5000 lux max.002756" 0.4 mm -1. ±0.95mW 20 μm × 550 μm 25 μm × 1400 μm 50 μm × 2000 μm 70 μm × 2500 μm 120 μm × 4200 μm Spot diameter (at reference distance) 0.20" ±5.02%of F.55/5/10/20/50/100/200/500/1000 μs (9 steps selectable) 0.S.32" 16.57" ±40 mm ±1.10 Class II Output 0. *4 When the ambient temperature rises to 40°C 104°F or more.91" Measurement range*1 ±0.8mW 0.165354" ±0.1μm 0./°C Temperature fluctuation (F./°C 0.8mW 0.8 mm ±0.24") (F.95mW 4.8mW 0.3mW 4. LK-H152/LK-H157: LK-F2 *5 When the ambient temperature rises to 40°C 104°F or more.1 μm 0./°C 0. *6 Value measured at an event of diffuse reflection installation./°C 0.S.6 mm to +14.S. Ambient temperature 0 to +50°C 32 to 122˚F *4 0 to +50°C 32 to 122˚F 0 to +50°C 32 to 122˚F *4 Relative humidity 35 to 85%RH (No condensation) Vibration resistance 10 to 55 Hz.S.S.000787" ø25 μm ø0.S. 300g *1 Measurement range when the sampling cycle is 20 μs or more.39" ±10 mm ±0. Transparent/mirror target measurement (mirror type) Model LK-H008 LK-H008W LK-H022K LK-H027K LK-H052K LK-H057K LK-H082 LK-H087 LK-H152 LK-H157 Mounting mode Specular reflection Specular reflection Specular reflection Specular reflection Specular reflection Specular reflection Specular reflection*4 Specular reflection*4 Reference distance 8 mm 0.3 mm 1.5 mm 0.42") (F.2 mm ±0.S.79") (F. Fine target measurement (focused spot type) Model LK-H008 LK-H020 LK-H022 LK-H050 LK-H052 LK-H080 LK-H082 LK-H150 LK-H152 Mounting mode Specular reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Reference distance 8 mm 0.S.= 6 mm 0.= 36 mm 1.02% of F.S.000984" ø50 μm ø0.02% of F.025 μm 0.02% of F.004724" × 0. ±0.82" 46.S.15")*6 Enclosure rating IP67 Environment resistance Incandescent lamp or Ambient light Incandescent lamp or fluorescent lamp: 10000 lux max.= 20 mm 0.= 6 mm 0. 280g Approx.02% of F./°C 0.001969" ø70 μm ø0.15") Enclosure rating IP67 Environment resistance Incandescent lamp Ambient light Incandescent lamp or fluorescent lamp: 10000 lux max.95mW 4./°C 0.91" 150 mm 5.000787" 0.02% of F.005 μm (0.39" ±10 mm ±0.01μm) 0.79" 20 mm 0.02% of F.97" 80 mm 3.001μm) 0.8 mm ±0.81" Measurement range*1 ±0.79" 50 mm 1.79") (F.098425" 0. *3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008) is measured at the reference distance with the number of averaging measurements set to 16384.= 6 mm 0.01% of F.1μm 0./°C 0.=1 mm 0.01% of F.000984" 0.02" ±3 mm ±0. ±0.=1 mm 0. 1.005 μm (0.S.= 80 mm 3.95mW ø20μm 20 μm × 550 μm ø25 μm 25 μm × 1400 μm ø50 μm 50 μm × 2000 μm ø70 μm 70 μm × 2500 μm ø120 μm 120 μm × 4200 μm Spot diameter (at reference distance) ø0. 240 g Approx.02% of F.15" 150 mm 5. 300g *1 Measurement range when the sampling cycle is 20 μs or more.79") (F.S.S.004724" ±0./°C Temperature fluctuation (F.8mW 0.S.= 20 mm 0.S.S.= 20 mm 0. The value in parentheses is a typical example of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 μs.01% of F. ±0.3 mm 1.32" 20 mm 0.01% of F.055118" ø0. Ambient temperature 0 to +50°C 32 to 122˚F *5 0 to +50°C 32 to 122˚F 0 to +50°C 32 to 122˚F *5 Relative humidity 35 to 85% RH (No condensation) Vibration resistance 10 to 55 Hz.S.S.97" 50 mm 1. *2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.004724" × 0.S.69" to +0.79") (F.15" 80 mm 3. mount this on a metal plate before use.42") (F.01% of F.95mW 4. and Z directions. 2 hours respectively Material Aluminum die-cast Weight Approx. 260g Approx.S P EC I FI C AT I O N S/S EN S O R H E A DS Coarse target measurement (wide spot type) Model LK-H008W LK-H025 LK-H027 LK-H055 LK-H057 LK-H085 LK-H087 LK-H155 LK-H157 Mounting mode Specular reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Diffuse reflection Reference distance 8 mm 0.=1 mm 0. mount this on a metal plate before use.025 μm 0.S.01% of F. • Non-voltage input rating: ON voltage: 1 V max.99 mm (7 settings selectable) N/A (LK-HD500) Display cycle Approx. 14 LK. (30 V max.5 V max. Maximum load resistance: 350 Ω No. Residual voltage: 0. ON voltage: 10.999 μm to ±9999. 10 times/sec. 300 g *1 This input is applied to all of the synchronized OUT. DARK Analog voltage output ±10 V output. Home Premium.). Either the display unit (LK-HD500) or Display port dedicated touch panel (LK-HD1001) N/A Display can be connected interface POWER ON. CO N T RO L L ER Main unit/head expansion unit Single unit type LK-G5001V LK-G5001PV Model LK-HA100 Separate type LK-G5001/LK-HD500 LK-G5001P/LK-HD500 Designation Main controller Head expansion unit Sensor head compatibility Compatible No. *3 When a PC supporting USB 1. *2 Home Premium.5 V max.2 V.6 A or less with 1 head/3.6 mA max. and Enterprise editions are supported.).001 µm Display Display range ±999. and Ultimate editions are supported.. a key-operated switch must be used for the input to this terminal.6 mA • Part of the input/output circuit of the LK-G5000 Series is internally common. refer to "Precautions on wiring" in the User's Manual. *5 Connection through a USB hub is not included in the guarantee. Output impedance: 100 Ω Analog current output 4 to 20 mA.5 A or less with 12 heads Environment Ambient temperature When one or less head expansion unit is connected: 0 to 50°C 32 to 122˚F When two or more head expansion units are connected: 0 to 40°C 32 to 104˚F resistance Relative humidity 35 to 85%RH (No condensation) Weight Approx. Pro. 600 g Approx. STABILITY. *6 Connection to LAN and connection via a router is not included in the guarantee.4 V. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/ external devices. LK-H2(LK-Navigator2) Operating environment CPU Pentium III 1 GHz or higher (1. *2 When the laser class 3B sensor head is connected.G5000 Series . Professional. the data refresh cycle and other operations may slow down.7 GHz or higher recommended) Supported OS Windows 10*1 Windows 7 (SP1 or later)*2 Windows Vista (SP2 or later)*3 Windows XP (SP3 or later)*4 Memory capacity 256 MB or more (1 GB or more recommended) Display resolution 1024 x 768 pixels. (40 V max. 24-bit full color or better Available hard disk space 1 GB or more The PC must be equipped with one of these interfaces: • USB: 2. the laser turns on when this terminal is opened and turns off when it is short-circuited. *4 Professional and Home editions are supported. (Select a key which can be removed only when it is set to the OFF position.0 full speed is connected. LED indicator LASER ON BRIGHT. of analog outputs 2 1 TIMING1 input*1 Non-voltage input Voltage input Terminal RESET1 input*1 block Auto-zero1 input*1 Non-voltage input Voltage input Laser control input*2 N/A Laser remote input Non-voltage input Alarm output NPN open-collector PNP open-collector General comparator output output output TIMING input Non-voltage input Voltage input RESET input Auto-zero input Non-voltage input Voltage input Expansion Program switch input N/A connector Binary selection input Alarm output NPN open-collector PNP open-collector Comparator output output output Binary output Baud rate: 9600 to 115200 bps RS-232C interface Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd N/A USB interface USB 2. The laser is emitted only when the key-operated switch is set to the ON position. • Voltage input rating: Maximum input rating: 26.1 compatible full speed)*5 Interface • LAN: 100BASE-TX. and Home Basic editions are supported. *3 Ultimate. Residual voltage: 0. • PNP open-collector output rating: 50 mA max. *1 Home. OFF current: 0. Business.) When the laser class 2/3R sensor head is connected.0 Hi-Speed compliant*3 Ethernet interface*4 100Base-TX/10Base-T Head expansion unit connector Up to 10 head expansion units can be connected to one main controller Either of the CC-Link unit (LK-CC100) or Expansion unit connector DeviceNet unit (LK-DN100) can be N/A connected 24 VDC±10% (Supplied from Power supply voltage 24 VDC±10% Power supply the controller) Maximum current consumption 0. 10BASE-T*6 * Use under an environment that exceeds the recommended environment of the your OS. • NPN open-collector output rating: 50 mA max. of connectable sensor heads 2 1 Minimum display unit 0. *4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.0 Hi-Speed (USB 1. For details. OFF current: 0.1 or USB 2. 4'.56'.81' length length Weight Approx. 2. 1150 g Rated voltage DC 24V±10% Current consumption 1A or less Sensor head-to-controller cable Extension cable between the head and cable Model CB-A07 CB-A2 CB-A5 CB-A10 CB-A20 CB-A30 Model CB-A5E CB-A10E Cable Cable 0.P RO D U C T L I N EU P & O P T I O N S Main controller Display Built-in type Separate display type Additional head unit CC-Link unit DeviceNet unit Touch panel display Compact display LK-G5001(P)V LK-G5001(P) LK-HA100 LK-CC100 LK-DN100 LK-HD1001 LK-HD500 Configuration Software Cable Neutral density filter Sensor head-to.40' 10 m 32.43' 5 m 16.3 mm 0. 750 g Approx. 10 m) 0.9 × 128. 5.81') Neutral density filter for the LK-H15x 3 m 9. 50. 20.G5000 Series 15 . 750 g LK.7 m 2. limit the absolute humidity to 85%RH at 40°C 104°F.01" double amplitude/57 to 500 Hz. IP65f equivalent dust-proof.04' Service life (normal temperature and humidity) Approx. waterjet-proof on only front panel Operating environment Limit dust and corrosive gas Ambient temperature 0 to 50°C 32 to 122°F Ambient humidity 35 to 85%RH (no condensation) When the ambient temperature is higher than 40°C 104°F. 98.81' 20 m 65.81': OP-51656 OP-66843 LK-F2 CB-A x x S P EC I FI C AT I O N S LK-G5000 Series Touch Panel Display Model LK-HD1001 Name LK-G5000 Series Touch Panel Display Display elements TFT color LCD Display color 32. Vibration resistance 10 to 57 Hz.000 hours Number of switches 40 x 30 per 1 image Touch Mode Matrix resistance membrane mode switch Operating force 0. Extension cable between Controller-to-display I/O Cable and Connector Neutral density filter for the LK-H08x controller cable the head and cable connection cable OP-51657 LK-F3 LK-Navigator2 (0.81'.73' x 5. 3 hours in each direction (X. 32.08' : OP-84427 LK-H2 (2. 6.62'. 10. 30 m) (5.40' 10 m 32.000 hours Backlight Type White LED lamp Service life Approx.33 m 1.43') CB-A xxE 10 m 32.2 6. 400 g Approx. (16. limit the absolute humidity to 85%RH at 40°C 104°F. 200 g Approx. 2000 g Weight Approx.768 colors Display Pixels (W x H pixels) 640 × 480 panel Display area (W x H mm) 170. 50. 100 g Approx. 16.30'.7. 32. and Z) Weight Approx.4'.62' 30 m 98. 0. 1400 g Approx. 400 g Approx.84': OP-51655 Ethernet cable 65. Y.98N or less Service life More than one million times Communication function Available only with the LK-G5000 Series Structure Panel built-in type. Storage temperature -10 to +60°C 14 to 140°F (no icing) Storage humidity 35 to 85%RH (no condensation) When the ambient temperature is higher than 40°C 104°F.30' 2 m 6.56' 5 m 16. 2G. 00 (Extended cyclic setting: Double or more)*2 Master unit CLPA-certified master unit (CC-Link Ver. IS EMITTED FROM MAXIMUM OUTPUT 0.4' (at transmission speed of 125 kbps)/250 m 820. LASER RADIATION- AVOID EXPOSURE DO NOT STARE INTO BEAM LASER RADIATION DO NOT STARE INTO BEAM AVOID DIRECT EYE EXPOSURE LASER RADIATION SEMICONDUCTOR LASER IS EMITTED FROM SEMICONDUCTOR LASER SEMICONDUCTOR LASER IS EMITTED FROM LASER RADIATION WAVELENGTH 655nm THIS APERTURE.20" 13 mounting ring 6. D I M EN S I O N S LK-HD1001 Touch Panel Display LK-HD500 Unit: mm inch PANEL CUTOUT DIMENSIONS Panel thickness 0.3'. 5 Mbps. Weight Approx. resistance Relative humidity 35 to 85 %RH (No condensation) Rated voltage 24 VDC±10 % (supplied from controller) Current consumption 200 mA max. 5 Mbps: 160 m 524.05" 178 128. 2. 1. 2. 300 g *1 CC-Link is a registered trademark of Mitsubishi Electric Corporation.21' (at 250 kbps)/ line cable length 125 m 410.44" 237 9. LK-DN100 (DeviceNet unit) Model LK-DN100 Designation DeviceNet communication unit dedicated to LK-G5000 Series Communication protocol DeviceNet*1 compliant Master unit ODVA-certified master unit Transmission speed 500 kbps.G5000 Series .33" 8.5 Mbps: 400 m 1312.94" 45 + 0.08' Station type Remote device station Environment Ambient temperature When one or less head expansion unit is connected: 0 to 50°C 32 to 122°F.10 IEC60825-1 Laser Class 1 Laser Class 2 Laser Class 3R FDA CAUTION AVOID EXPOSURE CAUTION AVOID EXPOSURE LASER RADIATION.8mW THIS APERTURE. WAVELENGTH 650nm WAVELENGTH 650nm THIS APERTURE.5 to 5 62 min.24" 0. 10 Mbps connection Connection cable Dedicated CC-Link cable supporting Ver.95" 0 5. 1 shielding cable) connection Maximum trunk Thick cable: 500 m 1640.57" 3.10 (Extended cyclic setting: Single) Ver.9(Effective display area) 6 43 46 1. (when network power supply 24 V is applied) Environment Ambient temperature When one or less head expansion unit is connected: 0 to 50°C 32 to 122°F.69" 75 + 0.7'.8mW EXPOSURE Wavelength 655nm Laser radiation is emitted from CLASS 3R LASER PRODUCT this aperture.73" 1. When two or more head expansion units are connected: 0 to 40°C 32 to 104°F. 2. Weight Approx. 3. *2 The LK-G5000 Series supports the "extended cyclic transmission" and "station-to-station cable length relaxation" of CC-Link Ver. When two or more head expansion units are connected: 0 to 40 °C 32 to 104 °F.01" 0.5 7.44" 170. 2. 125 kbps Device type Generic Network Transmission medium Dedicated 5 cables (2 signal cables.11' (at 500 kbps) Thin cable: 100 m 328. of occupied stations 1 to 4 Network Communication speed 156 kbps.81" 0.02" 51 0.6 0 1. S P EC I FI C AT I O N S LK-CC100 (CC-Link unit) Model LK-CC100 Designation CC-Link communication unit dedicated to LK-G5000 Series Supported CCLink*1 version Ver.77"+0. IEC/EN 60825-1 : 2007 16 LK. 300 g *1 DeviceNet is a registered trademark of ODVA (Open DeviceNet Vendor Association). 625 kbps: 900 m 2952. LASER RADIATION.6 +0.93" display area) 100 min.02" to 0. resistance Relative humidity 35 to 85%RH (No condensation) Rated voltage 24 VDC ±10% (supplied from controller) Current consumption 200 mA max.01"(Effective 6. 2. 2. 250 kbps.33" 0.51" Panel 62 2. 10 Mbps: 100 m 328. 2 power supply cables.3mW MAXIMUM OUTPUT 0. OP-79427) Maximum total cable extension length 156 kbps: 1200 m 3937'.58"3.95mW MAXIMUM OUTPUT 4.00. 625 kbps. CLASS LASER PRODUCT CLASS LASER PRODUCT CLASS a LASER PRODUCT IEC LASER RADIATION AVOID DIRECT EYE EXPOSURE AVOID Maximum output 4. 1.10) No.00/Ver.5 0 25 2.93'. 1.02" 0 2.08' (at all transmission speed settings) Communication type I/O communication (Poll) Explicit message communication Power supply 11 VDC to 25 VDC Current consumption 10 mA max.2 167 91 80 74.98" WARNING The LK-G Series conforms to the following FDA and IEC standards: LK-H008/ LK-H022/H022K/H027/H027K/H052/H052K/ LK-H020/H025/H050/H055/ Model LK-H008W H057/H057K/H082/H087/H152/H157 LK-H080/H085/H150/H155 FDA (CDRH) Laser Class Laser Class Laser Class a 21CFR Part 1040.10 (Shielded 3-core twisted-pair cable: OP-79426.5 Mbps.15" 2. 55" LK.13") (3.88" 4.13" LK-HA100 26.9 1.5 1.2) M4 Depth: 6 0.04" (2.1 2.24" 6 M4 Depth: 6 0.04" 5.55" LK-CC100 26.9 4.5 1.5 13.52") (13.41" 62.1 2.3 128 5.15" DIN-rail mounting position 124 124 4.88" 4.56") 4.88" 35.5 0.44" 0.24" 6 0.5 4xM4 Depth: 6 0.5 4xM4 Depth: 6 0.9 1.24" 0.13" 0.35" 9 0.24" 6 M4 Depth: 6 0.5 0.53" (0.88" 35.24" 13.88" 4.56" 5.56") 1.04" 4.04" (2.2) 105.56" (2.5 13.D I M EN S I O N S Unit: mm inch Controller LK-G5001(P)V LK-G5001(P) 65 128 (65) 65 (65) 105.9 1.1 2.53" (0.44" 0.24" 6 0.53" 13.13") 0.24" 14 114 4.04" (13.56") 2.41" 62.52") (13.1 2.24"6 0.15" DIN-rail mounting position 124 124 4.24" 6 M4 Depth: 6 0.5 0.3 128 (13.49" 14 0.53" M4 Depth: 6 0.55" LK-DN100 26.2) 105.53" 13.15" DIN-rail mounting position 124 124 4.15" DIN-rail mounting position 124 124 35.04" 1.24"6 47 47 1.04" 5.5 79.3 (0.13") 0.G5000 Series 17 .3 128 (65) 26.88" 4.41" 62.2) (0.24" (3.44" 0.85" 1.5 114 4.85" 9 0.53" 13.04" 4.24" 14 79.55" 3.3 (0.2) (0.56") 4.35" 34.24" 6 0.2) (0.13") (3.24" 1.5 2.2) M4 Depth: 6 0.2) (0.44" 0.49" 0.41" 62.88" 35.5 1.04" 1.88" 1.52") 26.24" 14 114 4.49" 0.24" (3.36" 3.52") 26.04" (2.3 (65) 105. 69" 74.4 1.4 51.5 0.4 ø0.79" 0.8 2.17" 4.1 0.9 max.40" 10.28" 0. 0.4 55.53" 0.2 0. D I M EN S I O N S Unit: mm inch Head ø14 ø0.48" LASER ON/STABILITY LED 10.6 66.36" ø14 ø0.55" LK-H008 / LK-H008W 55 2.70" 2.90" 40° 40° 2xø4.5" LASER ON/STABILITY LED 0.55" 55 2.47" 18 LK.36" 2.3 0.7 3.97" 1.06" 62 53.48" 0.5 2.32" 60 2.26" 2×ø4.99" 11 ø7 4.63" 20 4.89" 2.48" 68 7.23" 19.17" 16.2 12.44" 2. 0.59" 0. 68.94" Mounting hole 0.9 3.4 ø0.7 max.36" 0.4 30° 30° 50 0.40" 0. 77.5 57.32" 12.02" 89.53" 13.68" 0.4 2.51" 0.4 2.8 0.7 max.53" 13 max.28" 12.5 0.53" 0.69" 75.5 0.5 max.4 0.17" Mounting hole 0.9 2.17" LK-H050/LK-H052/ LK-H052K/LK-H057K LK-H055/LK-H057 500 19.18" 22.4 ø0.4 22.02" 89 max.02" 33. 24 2xø4.41" 12.17" Mounting hole 0.55" LK-H020/LK-H022/ LK-H025/LK-H027 LK-H022K/LK-H027K 55 2.1 max.8 90° 8 0.3 1.54" 68 2.69" 22.4 ø0.8 0.82" 9.8 1.2 35.2 0.1" 2.48" 66 2.46"11.02" 73.5 0.17" 0.5 59.17" 500 31.08" ø14 ø0.6 2.90" ø7 ø0.18" 15 13.2 1.7 13.17" 46.68" 0.30" 1.17" 500 19.6 1.G5000 Series .60" 27.28" 37.62" LASER ON/STABILITY LED 0.4 2.1 4.43" 0. 13.4 37.94" ø7 ø0.50" 3.30" 0.32" 1.5 1. 33.36" 9.1 0.87" 7. G5000 Series 19 .17" 500 19.3 10.91" 147.17" LK-H155 / LK-H157 500 19.7 max.30" Mounting hole 0.7 0.45" 11.30" 1.76" 2.30" 55 2.02" 9.56'.55" ø0.55" ø0.56" 61.3 3.69" 80.48" 7. 2 m. 35.4 ø0.3 3" 2.40'.55" 55 LK-H150 / LK-H152/ 2.17" 1.6 LASER ON/STABILITY LED 0. 2x ø4.81') ø14 ø14 33 (2.3 ø7 ø0.42" 69 2.28" ø0. 20 m.55" Unit: mm inch LK-H080 / LK-H082/ 55 LK-H085 / LK-H087 2.2 33. 10 m) (16.02" 0.17" 55 2.17" 1.27" 4.68" 67.1 max.40" 0.62'.39" 7.6 82.6 Mounting hole 76.7 max.02" 90.42') 1.30'.41" 3.8" 2x ø4.17" 24° 24° 80 3.D I M EN S I O N S ø14 ø0. 5 m.94" 0. 10 m. 70 3.24" 4 ø7 ø0. 32.4 2.65" 6.32" 0.36" 0.8 0.28" 20.4 0.72" 9 0.5 17° 5.53" 24 22.17" 0.17" 8.81" 20.2 18 0. 33.3 0.16" LASER ON/STABILITY LED 10.2 0.40" 0.28" 3.40'.71" 150 17° 5.32" 2.15" 76.1 0.5 LK.5 max.5 0. 98. 65.5 2.31" 0. 30 m) ø14 Cable length (5 m.55" (0.95" 0.16" 3.7 3.17" 55 2.89" 0.35" 4. 32.2 12.02" 26 0.28" Cable length ø7 ø0.4 ø0.4 13. 6.7 m.52" ø14 ø0.69" 86.81" Sensor head to controller cable CB-A07/CB-A2/CB-A5/CB-A10/ Extension cable CB-A20/CB-A30 [Cable between the head and cable] CB-A5E/CB-A10E ø7 ø0.5 1.81'.32" 1.5 75 38.2 68 84. 16.2 0. 75"±3.69"-9. Cutting-edge sensing technology and a wide array of sensor heads offer unmatched performance for any application. providing solutions to previously impossible applications. All rights reserved.com E-mail: [email protected]"/+19.011417" × 0.81" Measuring range 290 × 8300 µm Wide LK-G407 400±100 mm 0.011811" × 0.37" ø300 µm Spot LK-G502 ø0. HIGH-ACCURACY CCD LASER DISPLACEMENT SENSOR LONG RANGE TYPE LINEUP Revolutionary technology enables stable. WIDE-RANGE MEASUREMENT UP to 1000 mm HIGH-ACCURACY WIDE PRODCT LINEUP REPEATABILITY ±0.75" 500 mm 19.326772" 15.69" Detecting displacement of a water Measuring the thickness/width of a steel plate Thickness measurement/loop control of a rubber sheet www.374016" 19.011417" High-speed Long 2 µm Distance 300 mm 11.011811" Ultra Long 2 µm Distance 250 mm 9. LKG5-KA-C2-US 1126-8 611374 .69" ø290 µm Spot LK-G402 ø0.02 % 50 kHz 2 µm High-speed Long range Ultra long-range LK-G402/407 LK-G502/507 Type Spot type Model Reference distance & Measurement range Repeatability Beam spot dimensions 400 mm 15.com Copyright (c) 2010 KEYENCE CORPORATION.keyence. high accuracy measurement.LK-G3000 SERIES HIGH-SPEED.94" 500 mm 19.com E-mail: [email protected]" Measuring range 300 × 9500 µm Wide LK-G507 500-250/+500 mm 0.69" 1000 mm 39.com E-mail: keyence@keyence.
Copyright © 2024 DOKUMEN.SITE Inc.