Katalog English

March 28, 2018 | Author: yulizard | Category: Cable, Electrical Wiring, Insulator (Electricity), Electrical Conductor, Coaxial Cable


Comments



Description

CABLES AND WIRESNovi Sad, Republic of Serbia com. block 155. 21000 Novi Sad.Sales Centers • SERBIA AND EX-YU Republics NOVKABEL AD Industrijska bb.Str. Suite 5022 Empire State Building NY 10118 New York USA Tel: + 212 239 69 98 Fax: + 212 239 82 81 e-mail: [email protected] • RUSSIAN and CIS EPH Office.com www. Moscow Mantulinskaya Street dom 5.ru • WESTERN EUROPE East Point Holding Ltd. Sofia 16. str.com Romanian Trading Point S.point-group.con • CHINA YU POINT Ltd.com • CENTRAL AND EASTERN EUROPE M POINT KFT Fő utca 14-18 H-1011 Budapest Hungary Tel: + 361 34 57 810 Fax: + 361 21 25 804 e-mail: mpoint@mpoint. Izlak district. 2nd floor. Fr.LR. 6th (Floor) 1066 Nicosia Cyprus Tel: + 357 22 67 94 90 Fax: + 357 22 67 94 85 e-mail: [email protected] • USA Metalco Corporation 350 Fifth Ave. 1113 Sofia Bulgaria Tel: + 359 28 17 37 80 Fax: + 359 28 17 31 87 e-mail: [email protected] CABLES AND WIRES . 5. 010671 Bucharest Romania Tel: + 40 21 31 29 612 Fax: + 40 21 31 29 638 e-mail: epoint@rtpoint. 31 Evagoras Avenue. Building No. Piata Romana Sector 1. 100600 Beijing PR China Tel: + 86 10 653 21 551 Fax: + 86 10 653 26 955 e-mail: yupoint@netchina. Republic of Serbia Tel: + 381 21 44 23 38 Fax: + 381 21 44 23 40 e-mail: info@novkabel. 2-1-11 San Li Tun Diplomatic Compound Chaoyang District.Jalio Kuriy Str.com DP Handel GmbH Westendstrasse 24 D-60325 Frankfurt am Main Germany Tel: + 44 69 97 14 810 Fax: + 44 69 97 14 81 15 e-mail: [email protected]. apt 16. 3 123100 Moscow Russian Federation Tel: + 7 499 244 06 15/16 Fax: + 7 499 244 08 03 e-mail: [email protected] EPH Office. mill and bakery industry. wholesale grain trading. The majority of the business operations take place in Serbia. Research and development From its modest beginnings in the product range with a work of generations of employees on the development of new products. mining. shipbuilding. Objective NOVKABEL focuses on quality with utmost respect of the client's needs producing cables in accordance with quality standards and ecology requirements. the factory has achieved about 16. Romania. New York. 1 . Frankfurt and Beijing. improving sales by finding new markets.Company profile About us The Cable Factory based in Novi Sad was established in 1921 and is the oldest cable factory in the Balkans. telecommunication cables and cables for electronic equipment to suit various industrial needs of construction industry. a member of Point Group is a leading regional group with subsidiaries and associated companies that operate mainly in South East Europe. We supply a wide range of energy cables and conductors.000 registered products. expanding distribution network and strengthening relationships with business partners. automotive industry and other industries. as well as oil. river transport and real estate and engineering. NOVKABEL experts dedicate a lot of time to follow and implement the latest technical and technological achievements in cable industry. NOVKABEL.000 tons a year. transportation. Hungary and Austria. Quality We carry out all quality control procedures to ensure that all raw materials meet intake specifications and follow production until the dispatch of finished products. NOVKABEL IS A RECOGNIZABLE PRODUCTION BRAND IN CABLE INDUSTRY OF SOUTHEAST EUROPE BEING A LEADING PROVIDER IN REGARD OF QUALITY AND PRODUCT RANGE. The Company also has offices in leading world cities: Moscow. Capacity Novkabel production plant occupies an area of almost 40 hectares in the industrial zone of Novi Sad with the production capacity of up to 35. The core business activities of the Point Group are: copper processing and trading. Our objective is to remain market leader in the production and distribution of all types of cables. therefore the investment into control equipment is one of the Novkabel's priorities. Oil resistant.6/1 kV N(A)YCY 0. vacuum cleaners. electric power plants and switchgear assemblies. PVC insulated and sheated cable for supply or remote control. screened. for laying on plaster.INSTALLATION PVC INSULATED CONDUCTORS Type H05V-U H05V-K H07V-U H07V-R H07V-K H03VV-F H03VVH2-F H05VV-F H05VVH2-F Standard DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/3 DIN VDE 0281/5 DIN VDE 0281/5 DIN VDE 0281/5 DIN VDE 0281/5 DIN VDE 0276/603 Rated voltage 300/500 V 300/500 V 450/750 V 450/750 V 450/750 V 300/300 V 300/300 V 300/500 V 300/500 V PP/J P P/M P/F PP/L For connection of mobile user devices at low mechanical tensile strains. PVC insulated and sheated cable for supply or remote control. Single core non sheated cables are intended for wiring in pipes or raceways. Oil resistant. at medium mechanical strains.. electric power plants and switchgear assemblies. K – flexible conductor For connecting of mobile electrical appliances at low and medium mechanical tensile strains. U – wire. PVC insulated and sheated cable for supply or remote control. NYM 300/500 V PP SIGNAL CABLES NYSLY DIN VDE 0245/102 DIN VDE 0245/102 DIN VDE 0281/13 DIN VDE 0281/13 300/500 V NYSLYCY 300/500 V H05VV5-F (NYSLYО) H05VVC4V5 (NYSLYCYО) 300/500 V 300/500 V POWER CABLES N(A)YY DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 0. PP40(-A) For connection devices where cable is expected to provide electrical protection. XLPE insulated and PE sheated cable is used in urban networks and industrial plants.. at medium mechanical strains. in plaster or under plaster. N(A)2XY 0. PVC insulated and sheated cable for supply or remote control. Similar Application Single core non sheated cables are intended for wiring in pipes or raceways. lighting equipment and control instruments. for installations in the dry room. such as washing machines. electric power plants and switchgear assemblies. lighting equipment and control instruments. Suitable for installations in food industries. for installations in the dry room. R – rope. laundries and so on.6/1 kV XP00(-A) N(A)Y2Y 0. In dry and wet conditions indoors and in the open air. at medium mechanical strains.6/1 kV PP00(-A) PVC insulated and sheated cable is used in urban networks and industrial plants. Screened.6/1 kV 2 CABLES AND WIRES . XLPE insulated and PVC sheated cable is used in urban networks and industrial plants. at medium mechanical strains. on cable trays. middle-voltage and high voltage switchgear assemblies.6/1 kV PP45(-A) N(A)2XFGY 0. N(A)2XS2Y XHE48(-A) For laying indoors. For use in mines for electrical plants. Suitable for the networks which require minor reduction factor. N(A)YSY 6/10 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV PHP48(-A) In distributive lattice. N(A)YFGY 0. in ducts.6/1 kV PP44(-A) N(A)2XRGY 0. in ducts. XLPE insulated cable is used in urban networks.6/1 kV XP41(-A) N(A)YRGY 0. directly in earth. in urbane networks. in ducts. industrial plants and electric power plants. when mechanical damage could be expected. in the open air in distribution networks. thermo-power plants and electric power plants. industrial plants.6/1 kV XP45(-A) For laying when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. N(A)2XSY XHP48(-A) N(A)2XSEY For laying indoors. in the open air in distribution networks. in the open air. Laying down directly in the earth is limited by the mechanical properties of the PVC sheath. in earth and in the water. N(A)2XSYBY XHP81(-A) N(A)2XSEYB 2Y XHE81(-A) 3 . equipments and installations in mines. For laying indoors. For use in mines for electrical plants. in the open air. N(A)2XBY 0. equipments and installations in mines. Not provided for complicated conditions in terms of severe axial strains. For laying indoors. when mechanical damage could be expected. N(A)2XSE2Y N(A)2XS(F)2Y XHE49(-A) N(A)2XS(FL) 2Y In distributing network mains. directly in earth.6/1 kV XP44(-A) For laying when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. industrial plants and power plants. industrial plants and electric power plants. in ducts.6/1 kV Similar PP41(-A) Application PVC insulated cable is used in urban networks. industrial plants and power plants and always when better electrical protection is required. industrial plants and electric power plants. industrial plants and electric power plants.POWER CABLES Type N(A)YBY Standard DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/603 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 Rated voltage 0. when cables are exposed to aggresive and wet surrounding effects. directly in earth. 6/1 kV Similar XHP84(-A) Application In urban networks. For distributive low-voltage air networks in urban areas. For supplying portable or light mobile appliances with low mechanical stresses (e.315 300/500 V PP/O RUBBER CABLES H01N2-D DIN VDE 0282-6 200 V ZN/S Cable is intended for machine and hand welding with very high mechanical stresses. CABLES AND WIRES H01N2-E DIN VDE 0282-6 200 V H05RR-F DIN VDE 0282-4 300/500 V NFK EpG H05RN-F DIN VDE 0282-4 300/500 V H07RN-F DIN VDE 0282-4 Production Specification of Novkabel 450/750 V 450/750 V NFK EpN 50 4 . Especially flexible cable is intended for machine and hand welding with very high mechanical stresses. Self-supporting insulated wires are intended for distributive high-voltage air networks. for air household connections. cooking appliances). For distributive low-voltage air networks in urban areas. electric irons. in the open air and in earth.C5. for air household connections.POWER CABLES Type N(A)2XSEY RGbY N(A)2XSEY RGb2Y N(A)2XSEY FGbY N(A)2XSEY FGb2Y Standard DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276/620 DIN VDE 0276 SRPS N. Cable is recomended if torsion stress exists. For supplying portable or light mobile appliances with low mechanical stresses (e. cooking appliances). in the open air and in earth. support brackets or steel constructions. XHE84(-A) XHP85(-A) XHE85(-A) In urban networks. Multicore cable is used for connection appliances with medium mechanical stresses.g. For laying in ducts.250 GOST R 52373 Rated voltage 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV 0. On pillars. NFA2X X00-A 0. electric irons.6/1 kV X00/O-A SIP 3 12/20 kV SRPS N. vacuum cleaners. for air household connections. industrial plants and power plants. site temporary connections. EpN 50 It is suitable for connecting electrical appliances and tools. when the cable is exposed to severe mechanical tensile strains during laying down or use. industrial plants and power plants. vacuum cleaners. when the cable is exposed to severe mechanical tensile strains during laying down or use. including industrial and agricultural equipment with medium mechanical stresses.C3.g. and so on. For laying in ducts. In the open air for public illumination (lamps carring is possible). NSSHöu …/3E 0.6/6 kV 6/10 kV 12/20 kV 20/35 kV Cables are intended for operating in extremely heavy conditions on surface pit mines.6/6 kV 0. damp and wet conditions as well as outside. conveyor systems.6/1 kV EpN 55 0. for connecting high voltage movable transformer.C5.6/1 kV NSSHöu …/3 0. NSHTöu DIN VDE 0250-814 0.364 3.6/1 kV 1.6/6 kV NSGAFöu NSGAFCMöu DIN VDE 0250-602 3.6/1 kV NFK EpTN NSSHöu DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-812 DIN VDE 0250-813 DIN VDE 0250-813 DIN VDE 0250-813 0.8/3 kV 3.6/1 kV 1. as well as for lighting. Flexible rubber cable is used in electrical vehicles for current circuits for current for heating and control. in surface and methanes pit mines. They are suitable for supply of heavy excavators. Flexible rubber cable with protective conductor is used in electrical vehicles for current circuits for current for heating and control. lifting equipment. shipyards. such as cable reels. 5 .6/1 kV 3. SRPS N. cranes truck transporters loading bridges and other machines.8/3 kV 3.6/1 kV Rubber flexible cables are intended for the operations in heavy conditions.6/6 kV BT UIC 895 HT 750 V ŽEpN 1500 V 3000 V Flexible rubber cable is used in electrical vehicles for current circuits for current for heating and control. NTS …/3E EpN 78/53 NTS …KON EpN 74 Flexible medium voltage cable is intended for operation in mines with underground exploitation. driven motors. quarries and industry. Rubber cable is intended for electrical vehicles. shipyards. in dry. as well as for lighting.6/1 kV EpN 63 EpN 78 0.6/1 kV EpN 53 NSSCHöu NSSCHöu … KON NTS … /3 0.6/6 kV EpN 65 NSGAöu DIN VDE 0250-602 DIN VDE 0250-602 0.RUBBER CABLES Type Standard Rated voltage Similar Application Cable is intended for connecting mobile appliances with high mechanical stresses. quarries and other type of industry. as well as for lighting. are particularly suitable for installation which should be functional in the case of the fire (power supply pumps.6/1 kV FMGCG DIN 89160 250/250 V HALOGEN FREE CABLES H05Z-U DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-9 DIN VDE 0282-13 DIN VDE 0266 DIN VDE 0266 DIN VDE 0266 DIN VDE 0266 300/500 V Halogen free single core non sheated cables with improved characteristics in the case of fire are intended for wiring. as signalling and control cables. signalling and control cables. use in all rooms and on open board. Rubber insulated cable with protective conductor is used for fixed laying on ships and off-shore units. signalling and control cables. are intended for installation in the object where there are rather large requirements for safety of people. conveyor systems and large machines with medium mechanical stresses and torsion. use in all rooms and on open board. as power. equipment to extinguish a fire. use in all rooms and on open board.6/1 kV 0. Teledommunication shipboard cable is used for fixed laying on ships and off-shore units. for installations in the dry room. with concentric conductor (C) or not. These cables. panic lighting. Flexible rubber cable is intended for pumps under water.R H07Z-K 450/750 V 450/750 V Halogen free single core non sheated cables with improved characteristics in the case of fire are intended for wiring in pipes or raceways.6/1 kV 0. for installations in the dry room. lighting equipment and control instruments. and installations with medium mechanical stresses. lighting equipment and control instruments. NFK SiSi/J Silicone flexible flat cable is used for connecting mobile parts of the machines.6/1 kV . etc). ventilators for pulling out of smoke. Halogen free cables. signal and control cable. as power. These cables are used for connecting electrical appliances and tools. CABLES AND WIRES H07ZZ-F 450/750 V NHXHX NHXCHX NHXHX FE180 NHXCHX FE180 6 0.RUBBER CABLES Type Standard DIN VDE 0250-609 Production Specification of Novkabel Production Specification of Novkabel MGG DIN 89159 Rated voltage Similar Application Rubber flexible flat cable is used for connecting mobile parts of the machines.6/1 kV 0. Rubber insulated cable is intended for fixed laying on ships and off-shore units. H05Z-K H07Z-U 300/500 V 450/750 V H07Z. NGFLGöu 300/500 V 300/500 V 450/750 V NFK TES 0.6/1 kV MGCG DIN 89158 0. conveyor systems and large machines as power. with concentric conductor (C) or not. For installation in areas with risk of fire.6/1 kV 250 V 250 V 300 V 300 V J-H(St)H 300 V JE-H(St)H 300 V NHMH 300/500 V NHXMH 300/500 V N2XH 0.HALOGEN FREE CABLES Type LiHXHX Standard Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel Production Specification of Novkabel DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 0250/215 DIN VDE 0250/214 DIN VDE 0276/604 Rated voltage 0.6/1 kV 0. Flexible halogen free cables with concentric conductor are intended for installation in the object where there are rather large requirements for safety of people. are particularly suitable for installation which should be functional in the case of the fire (power supply pumps. panic lighting. Flexible halogen free screened cables with improved characteristics in the case of the fire.6/1 kV Similar Application Flexible halogen free cables are intended for installation in the object where there are rather large requirements for safety of people. For installation line on place where is indispensable to reflect communication in fire long period of time. Installation halogen free cables with improved characteristics in the case of the fire.6/1 kV 6/10 kV 12/20 kV 20/35 kV 6/10 kV 12/20 kV 20/35 kV N(A)2XSH N(A)2XSEH Halogen free cables is used in distribution networks. 7 . equipment to extinguish a fire. Also suitable as fire alarm cable. ventilators for pulling out of smoke. Installation telecommunication cable for installation line or introducing several lines into buildings. Installation telecommunication cable for installation line or introducing several lines into buildings. LiHXCHX 0. For transmission of analogous and digital signals. Power halogen free cables with improved characteristics in the case of the fire.6/1 kV LiHXHX FE180 LiHXCHX FE180 LiHH LiHCH J-HH J-2Y(St)H 0. industrial plants and electric power plants. Installation halogen free cables with improved characteristics in the case of the fire.6/1 kV N2XCH DIN VDE 0276/604 DIN VDE 0276/622 DIN VDE 0276/622 0. Flexible halogen free cables with improved characteristics in the case of the fire. with concentric conductor (C) or not. These flexible cables. Power halogen free and screened cables with improved characteristics in the case of the fire. etc). when mechanical damage could not be expected. St III Bd A2YF(L)2Y. use in all rooms and on open board. Bd 2YY J-Y(St)Y JE-Y(St)Y A02Y(L)2Y. Serbia 8 . Self-supporting low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines.6/1 kV TELECOMMUNICATION CABLES S-YY DIN VDE 0813 DIN VDE 0813 DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 0815 DIN VDE 816 DIN VDE 816 For transmission of low-frequency commands in signalling equipment. It is laid at supports on the ground walls. use in all rooms and on open board. Filled low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines.. As leadingin insulated conductor in dry and damp operating area. For installation line or introducing several lines into buildings.. Halogen free cable with protective conductor is used for fixed laying on ships and off-shore units. St III Bd A2Y(L)2Y. as power. as power.. rooves. Low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines. For installation line or introducing several lines into buildings. signalling and control cables. use in all rooms and on open board. Screened halogen free cable is used for fixed laying on ships and off-shore units. Low-frequency telephone subscriber cable with foam and skin PE insulation is used in local network for subscriber and trunk lines..HALOGEN FREE CABLES Type Standard DIN VDE 0276/622 Rated voltage 6/10 kV 12/20 kV 20/35 kV Similar Application Halogen free cables is used in urbane networks. when mechanical damage could be expected.6/1 kV FMGCH DIN 89160 0... industrial plants and power plants. For transmission of low-frequency commands in signalling equipment.6/1 kV MGCH DIN 89158 0.. signalling and control cables. Halogen free cable is used for fixed laying on ships and off-shore units. It is laid in cable ducts or into the ground. St III Bd DIN VDE 816 TK 33 U PTT. as signalling and control cables N(A)2XSEHBH MGH DIN 89159 0. CABLES AND WIRES S-Y(St)Y J-YY . Installation cable for permanent connection in industrial electronics.. It is laid directly into the ground. Symmetrical pair cable for digital transmission (up to 30 MHz). is used in local network for subscriber lines.. GM PTT. Flat telephone cord for connector connections are intended for connecting telephones with telephone installation. Serbia . Self-supporting low-frequency cable is used in network group for trunk lines when there is the inductive influence of power lines. St I Bd J-2Y(St)Y TD 36 U-P TD 39 M PTT. Cable for digital transmission is used in network groups for low-frequency transmission or digital transmission up to 2Mbits/s. Installation cable for computer networks is used in local networks for data transfer or in networks for automatic control. Serbia PGA4 PTT Serbia DP Production Specification of Novkabel SEZ JŽS. Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines. PVC insulated cables for the connection of railway station signalsafety units on electrified railwaytracks. M. M. Control cable for differential protectionvoltage difference measurement or the current at input and output of power equipment. Serbia PTT. 9 PTT. for direct laying into the ground... Serbia SPZ JŽS. Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines where the inductive influence of power lines is to be expected.. for direct laying into the ground.TELECOMMUNICATION CABLES Type TK 39 TP .. GMR Production Specification of Novkabel TK 59 MRL. GMRL Production Specification of Novkabel DIN VDE 816 DIN VDE 0815 PTT. PE insulated cables for the connection of railway station signalsafety units on electrified railwaytracks. Serbia A02Y(L)2Y. Low-frequency cable for network group with foam-skin PE insulation is used in local network for trunk lines.. Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines where great influence of power lines is to be expected. Armoured cable for digital transmission is used in network groups for low-frequency transmission or digital transmission up to 2 Mbits/s. Serbia TK 59 MR. Serbia TD 59 TP. GM Standard Rated voltage Similar Application Filled low-frequency subscriber cable with solid PE insulation is used in local network for subscriber lines. Serbia TK 59 TP . OP TK 59 DSL (30) PTT. where screening of audio signal is needed for protection from the disturbance. YV DIN VDE 0812 TI 20 As insulated conductor for wiring in telecommunication or data processing devices. Cable are being used for production of flexible connections between power amplifier and loudspeakers in studio monitor systems and professional sound systems.pair audio cables is used in professional audio systems of all kinds. with movable connecting cables with XLR connectors. are intended for wiring of all kinds of electronic and medical devices Equipment wires (flexible conductor) with insulation of ETFE mass are intended for automatic or semi-automatic panel connection in computer technics. It is intended for production of connecting cables with XLR connectors and transmission of the microphone signal.WIRING CONDUCTORS Type Standard Rated voltage Similar Application Y DIN VDE 0815 TM 20 As installation insulated conductor in dry and damp operating area. (Li)5Y DIN VDE 0881 (Li)6Y DIN VDE 0881 (Li)7Y DIN VDE 0881 CABLES FOR AUDIO SYSTEMS NAUK 001 NAUK 002 NAUK 003 Production Specification of Novkabel Sub miniature cable is intended for performing internal connections between some points inside audio devices. in telephone centrals and aero industry for wiring of all devices that need high level of mechanical resistance. are intended for wiring of electronic and electric devices where working conditions are demanding high temperatures (up to 250°C) Equipment wires (flexible conductor) with insulation of FEP mass. Equipment wires (flexible conductor) with insulation of PTFE mass. Multi pair audio cable is being used everywhere where is grouping of the related lines needed for transmission of the signals with optimal usage of the available space. CABLES AND WIRES NAUK 100 Production Specification of Novkabel NAUK 200 Production Specification of Novkabel NAUK 300 Production Specification of Novkabel NAUK 900 Production Specification of Novkabel 10 . Cable is intended for connection of the technic speaker-phones three.wire asymmetric connection configuration. One. control. Serbia TO SM 19 PTT. measuring and regulation technics. in long. is intended for general usage in professional telecommunication technics and radio amateurism. TO SM 03 PTT. During the transmission of VF signals through these cables it comes to generating of exceptionally small noise.metallic optical fibre cables are specially suitable for the application on relation along with electro. in the areas with common discharging and in the transfer equipment of the electric economy because they are totaly unsensitive for all kinds of electromagnetic influences and atmosphere discharging. is being used in a wide range of commercial electronics and high. Serbia COAXIAL CABLES MIL C-17/28C. computer technics. It is used for wiring of telecommunication equipment and equipment for data processing too.tractive lines. LiYY DIN VDE 0812 250 V LiYCY DIN VDE 0812 250 V OPTICAL FIBER CABLES OKZPP1 Production Specification of Novkabel Optical fiber cable is suitable for indoor and outdoor aplications. RG 50 Ω RG 75 Ω MIL C-17/78B MIL C-17/77C UNINSULATED CONDUCTORS Aluminium conductors. Flexible screened cable is intended for impulse and data transmission in electronics. control and regulation technique. Optical fiber cables manufactured according to these technical conditions can be used in local telephone networks as a connecting cables. MIL C-17/74C Coaxial cable with RG mark and characteristic impedance of 50 Ω. Non. Coaxial cable with RG mark and characteristic impedance of 75 Ω. 11 .frequent technics and everywhere where is transmission of VF signals with less noise transmission needed.distance cables. DIN 48 201 Conductors for overhead power lines. steel reinforced Hard copper and bronze stranded conductors DIN 48 204 Conductors for overhead power lines.ELECTRONIC CABLES Type Standard Rated voltage Similar Application Flexible cable is intended for connection in measuring.distance telephone networks as a long. 5. Copper wires (bare or tinned) DIN VDE 0295 class 1.2. Flat braid DIN 72 333 Very flexible braid Production Specification of Novkabel For partial screening and similar applications in electronics. Wire for Production erosimat zinc Specification plated copper of Novkabel wire (MCV) Brass wire MS 63 SRPS C. They are used for the grounding of the electrical units. 12 CABLES AND WIRES . Aluminum wires For use in cable industry and for other products like rivets.UNINSULATED CONDUCTORS Type Aluminum conductors Standard DIN VDE 0295 class 2 Rated voltage Similar Application For the cable industry.6 (bare or tinned) DIN VDE 0295 class 2 For the cable industry. ect.C0.6 In cable industry. They are used for connections with earth connections in electronics and in automobile industry for brushes in electromotors. and other products of general purposes. Using MCV wire enable faster cutting up to 30%. conductors SRPS of copper N. DIN VDE 0295. for elektrotechnical and other products.015 and aluminum class 2 Very flexible flat braid DIN 46444 For the cable industry.D1.2. Profiled stranded NF C 32-321.5. For use in sparc erosion units which use wire as electrode. and in the automobile industry. Round stranded DIN VDE conductors 0295 copper class 1. Stranded conductors with overall copper braid DIN 46440 They are used for connections with earth connections in electronics and in automobile industry for brushes in electromotors.120 For sieves. Certificate . com www.com .novkabel. 11000 Belegrade.com Point Group Francuska 6. Republic of Serbia Tel: + 381 21 44 23 38 Fax: + 381 21 44 23 40 e-mail: [email protected] www. 21000 Novi Sad.point-group.member of Novkabel AD Industrijska bb.point-group. Republic of Serbia Tel: + 381 11 33 46 444 Fax: +381 11 32 34 431 e-mail: yupb@eph.
Copyright © 2024 DOKUMEN.SITE Inc.