Description

Isolated Phase BusGenerator Leads with current ratings from 6 kA up F toor Main 50 kA, Isolated Phase Bus is the solution. Isolated Phase Bus systems are used exclusively for Main Generator Leads where minimal external electro-magnetic fields and maximum phase to phase fault protection is required. TECHNIBUS™ offers a complete line of Isolated Phase Bus systems for those situations calling for high currents with maximum integrity. TECHNIBUS™ can provide continuous current ratings from 1,200A up to 50,000A with short circuit ratings up to 900,000A. Conductor (A) he conductor consists of high conductivity, conductor T grade aluminum. Depending upon the diameter required, extruded tubes or tubes rolled of plate metal are used. The tube’s shape permits exact calculation of current displacement and heat dissipation as well as the short circuit forces. Aluminum expansion elements with welded connections allow for thermal expansion of the conductor. Maintenance is not required. Enclosure (B) nclosures are also made of high conductivity, conductor grade aluminum. The enclosures are E manufactured from rolled sheet or plate of variable diameters and wall thicknesses and are welded together by using the inert-gas-shielded-arc process. The enclosure is self-supporting up to a length of approximately 65 feet, allowing a free choice of the fixed points. Expansion joints in the form of aluminum bellows provided at the terminations permit thermal expansion. Post Insulators (C) resin post insulators support the conductor and are arranged in the enclosure so as to ensure the Cast proper clearance in air between the conductor and earthed enclosure. A sliding surface provided at the post insulator head permits relative movements between enclosure and conductor in an axial direction. One insulator of each support system is equipped with an adjustable spring-type element for compensating any variance in tube diameters during mounting as well as any conductor movements caused by a short-circuit. B A Conductor Enclosure C Post Insulator Please contact your local sales representative to request our complete Isolated Phase brochure. 1501 Raff Road SW Canton, OH 44710 http://www.technibus.com [email protected] ☎ 330-478-6395 6 32.1 14.25 35.032 0. Capacitance Inductance µPico-Farads Henries per per Ft.4 25.024 0.00 28./3-Phs Loss per FT.8 17.75 41.25 28.75 82.100 0.029 0.058 0.90 0.38 42.074 0.033 Table for dimensions and locating distances All dimension sizes are in inches Typical Isolated Phase Bus configuration.27 KV 150 KV BIL 80 KV Hi-Pot 3000 6000 8000 9000 10000 11000 12000 14000 16000 17000 20000 22000 24000 26000 30000 32000 (D1) Cond (D2) Encl Dia (in.048 0.50 25.50 57.75 46.00 11.90 0.00 53.00 47.technibus.033 670 1476 31.50 50.00 47.25 36.041 0.24KV 110/125 KV BIL 50/60 KV HiPot 23KV .50 21.022 0.00 18. 1501 Raff Road SW Canton.50 14. OH 44710 http://www.8 21.041 0.50 32.036 0./Phase Ft/Phase 112 115 139 164 163 182 215 263 302 304 387 421 456 544 626 160 392 528 584 694 758 698 741 838 946 1090 1198 1306 1294 1397 10.048 0. 60HZ) Rated Voltage Rated Current 15KV .0 39.63 25.75 Watts Wt.00 39.2 28.63 51.) (A) Phs Spc (in) 4.4 21.25 26.38 39.058 0. 3-Phs Ft.00 35.1 25.026 0.) Dia (in.00 7.00 63.00 67.50 31.75 39.com [email protected] 43.75 32.1 17.75 29.50 21.50 59.com ☎ 330-478-6395 .TECHNIBUS IPB DESIGN PLAN (65C RISE/40C AMBIENT.9 36.00 71.75 31.38 67.
Copyright © 2024 DOKUMEN.SITE Inc.