GEODIMETER SYSTEM 600 ATSMAINTENANCE MANUAL CHAPTER 1-TECHNICAL DESCRIPTION 600ATS.01.321.00.1 Chapter 6 - Info codes Error types 0 1 2 Jumps to monitor for repetition of state No return Infinite loop Return to calling program after one second delay 3 4 5 Return to calling program after 5 beeps Return to calling program Return to calling program after 5 beeps and key pressed Device numbers .0 .1 .2 .3 .4 .5 .6 .7 .8 .9 .10 .11 .12 .13 .14 .15 GDT RS232 Imem Xmem Second RS232 Card Memory Radio Distance PVX/Alidad Servo Tracker Angle 6-1 i 24. registration not possible Bat low.i 21.1 Info codes Code Type Description 1 2 3 3 3 4 3 Plum out of range Wrong face Aim mode Distance already recorded Measure invalid 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20.i 22. try to step outside a file. general error No or wrong device connected Time-out Illegal state to execute command. Vertical difference < 5 Not Active 3 3 3 3 Not correct section.i 31 32 3 3 3 3 3 3 3 Undefined mode switch or table Angle <15° from Hor plane UDS contains distance labels Bat low. can’t be altered Syntax error Out of range. Roadline Remote active Autolock active CU not on alidad Error occurred during transmission Illegal label number Serial communication RS232. in external unit.i 29 30.321. (load/output) Real time clock error Backup battery to old Option not installed No data in buffer Table activated.01. Not found (files or programs) 3 3 3 3 3 3 3 3 3 3 6-2 .i 23.GEODIMETER SYSTEM 600 ATS CHAPTER 1-TECHNICAL DESCRIPTION MAINTENANCE MANUAL 600ATS.i 27 28. No active device.i 25 26.00. 321. database changed. Roadline.i 36 37 38 39 40 3 3 3 Error in file / record separator / file creation Data error Memory full 3 To many offset values.GEODIMETER SYSTEM 600 ATS CHAPTER 1-TECHNICAL DESCRIPTION MAINTENANCE MANUAL 33 600ATS.01. value Not enough data for calculation 3 1 3 4 4 GDM power error. Process time-out (process sent to PVX) 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 3 3 Wrong type UDS Program memory full Square root of neg.00. radio can’t switch on GDM UDS Call stack error Stn.1 File / Record exists 34 35. No GDM connected Wrong configuration number Checksum error Control Unit not initiated 6-3 . GEODIMETER SYSTEM 600 ATS MAINTENANCE MANUAL CHAPTER 1-TECHNICAL DESCRIPTION 600ATS.1 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 6-4 .01.321.00. S register. or locked command. after executed radio command.x.1 Radio unit Code 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 Type Description 3 3 OK. No carrier. Error. after radio reset No Access. 3 Channel Busy or time-out sending. hardware Invalid channel Georadio ver. Japanese radios only.01. Radio error NAK Radio error CAN Radio not connected.GEODIMETER SYSTEM 600 ATS CHAPTER 1-TECHNICAL DESCRIPTION MAINTENANCE MANUAL 600ATS.321. command syntax error or command not executed. Ring. 3 EEPROM error EEPROM OK PLL unable to lock.00. connection established. another radio is calling. Time-out after radio command Time-out Ack/Nak Invalid channel 6-5 . Connect. x. Transmission blocked. noise or no contact. 00.GEODIMETER SYSTEM 600 ATS MAINTENANCE MANUAL CHAPTER 1-TECHNICAL DESCRIPTION 600ATS.1 135 136 137 138 139 Radio protocol error Card Memory Code 140 141 142 143 144 145 146 147 148 149 Type Description General system error 6-6 .01.321. Multiply error.00.Tracker communication failed. Hor & Ver accuracy not reached. Vertical accuracy not reached. (Translated to 30 by PVX) Data error or data missing.1 Servo system Code 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 Type Description 3 3 3 3 OK. Distance unit Code 170 171 172 173 174 175 176 177 178 Type Description 3 3 3 3 3 Subtraction or addition error.1´-´. Overload vertical motor.01. Distance > 32 Km. End position switch. Target lost. 3 3 3 Unable to measure distance. no signal from prism. Gang error. Target not found. 3 3 3 3 3 3 3 Horizontal accuracy not reached. Overload horizontal motor. Tracker collimation error > 5 c. Syntax error. Signal lost close loop. Divide error. Servo command executed. Servo . Locked onto target Not valid position angle. Tracker collimation error < 100m. Hardware failure 6-7 . (Translated to 35 by PVX) Unable to initialise.4´ is the knob number.GEODIMETER SYSTEM 600 ATS CHAPTER 1-TECHNICAL DESCRIPTION MAINTENANCE MANUAL 600ATS.321. ´. RS232 6-8 .GEODIMETER SYSTEM 600 ATS CHAPTER 1-TECHNICAL DESCRIPTION MAINTENANCE MANUAL 600ATS.321.1 210 211 212 213 214 User Break (of PVX process) General failure of command to alidad 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Unable to allocate resource Unable to deallocate resource resource not allocated Interrupts are enabled in monitor program DO CASE-index to large in PLM Case index in state tbl to large Divide by zero See error 218 Text not found To many labels Illegal vector To many devices Process queue 0 overflow Process queue 1 overflow Illegal interrupt Monitor stack overflow CPU stack overflow Text string has no end mark Wrong channel.01.1 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199.i 200 201 202 203 204 205 206 207 207.00. 321. Divide error. General process error. Wrong vertical coarse code.GEODIMETER SYSTEM 600 ATS CHAPTER 1-TECHNICAL DESCRIPTION MAINTENANCE MANUAL 600ATS. Wrong offset Algebra error Automatic adjustment horizontal not possible. Process active. No active process. Execution of process terminated. Wrong pendulum reference.i 219 3 3 3 3 Wrong Dst_type Serial channel RS-buffer overflow Input string overflow Wrong parameter Angle unit Code 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 Type Description 3 3 3 3 3 3 3 3 3 3 3 3 Wrong horizontal raw data from angle detector. Automatic adjustment vertical not possible. Start of pendulum not possible. Wrong vertical raw data from angle detector.1 215 3 Wrong Src_type 216 217 218. Wrong process number. Wrong horizontal coarse code. Process time-out. Process code overflow.00. 6-9 . Process stack error. Unit required by a process not active.01. 1 248 Process failed. 249 250 251 252 253 254 255.i Fatal error 6-10 .00.321.GEODIMETER SYSTEM 600 ATS MAINTENANCE MANUAL CHAPTER 1-TECHNICAL DESCRIPTION 600ATS.01. 2 5 6 10 16 17 18 19 20 21. The operation was carried out in the wrong face (C1/C2).4 21. Appear if prg.321.or output-table that doesn’t exist.or Area-file.00. Appear if confirmation on required process isn’t given. Wrong label entered. Appear if a external device (ex. 6-11 .i 21. Collimation test only possible to perform with the control unit attached to the instrument.2 21. General serial communication error.1 Descriptions The following pages will describe some of the most common info codes. Too many offset values in Roadline program. The operation was carried out while the instrument was in an illegal mode. GDT 500) or internal (ex. Appear if prg. Tries to insert a label in the editor when you have a Job or a Area No in the display. Tries to use a display. distance unit) unit isn’t active. The compensator can’t compensate for the inclination. Overrun error Parity error Framing error Received error Error occur during a communication session. Tries to choose illegal or non existing display. Code Explanation 1 The instrument is tilted too much. The vertical angle is less than 15 gon from the horizontal angle during a collimation test. 22 or 28 is activated in remote mode. General communication error. Appear if a collimation test is carried out.01.or output-table.GEODIMETER SYSTEM 600 ATS MAINTENANCE MANUAL CHAPTER 1-TECHNICAL DESCRIPTION 600ATS.1 21. Tries to create an illegal UDS Illegal way of creating a Job.8 23 24 30 31 33 34 39 40 Tries to send a command with illegal syntax on the serial channel. 22 or 28 is activated in Autolock mode. Station isn’t established. 50 51 54 153 171 172 173 174 175 190 191 197 198 199 200 201 206 207 207. Could be follow up info to 175. You will then get different number of pulses in the phase meter and a random distance (over 32 km) as a result. Distance error. Station labels has been change since the station was established. should be informed before the program start (monitor). Tries to position the instrument to an illegal angle.1) Appear if the stack (part of the RAM memory that is reserved for temporary storage of bytes by the microprocessor) is too long (monitor). Tries to execute required process and wrong confirmation is given. MAP) with another internal unit (ex.00. 4 steps).01. Could be follow up info to 175. the distance meter) but fails due to the serial channel (in the instrument) is busy. Could be follow up info to 175. Appear if the processor receive another command before execution of the latest one. Tries to communicate (ex. Can appear if the operator press a key too many times. Instrument/Control Unit not initiated. ex.321. 6-12 . given when the operator exits a program (press no button). could appear if the operator change from one prism to another with different distances very quickly in the same phase (F1/F2/F3).GEODIMETER SYSTEM 600 ATS CHAPTER 1-TECHNICAL DESCRIPTION MAINTENANCE MANUAL 600ATS. Calculation error. No signal internal lightpath. Same as 207. Calculation error. Internal info.1 41 This label type can’t be attached to this specific label.4). version) Checksum error. Interrupts are not allowed in the monitor program (important program within the program). index. Incorrect values for execution. (check prg. 43 44 48 Calculation error. Appear if the queue of command to the microprocessor is more than 10 (second RS232. (RS232 index.1 211 Calculation error. Calculation error. Incorrect execution. Call is used in too many steps (max. Wrong configuration number. 321. wrong source with the COM. program. Calculation error due to too large values. (COM.01. (CPU).GEODIMETER SYSTEM 600 ATS MAINTENANCE MANUAL CHAPTER 1-TECHNICAL DESCRIPTION 600ATS.00. Data was sent without an end sign. If the balance between the two is too large info 227 will appear. program. Internal info. 214 215 RS232 (index. wrong destination with the COM.1 212 Same as 211. 216 217 218 219 227 231 6-13 . A command that is too long was sent on the serial channel.4) Internal info. = program that transfers data internally) Internal info.1) or Second RS232 (index. Data is collected and calculated at the same time.