Ice Ace 07003 Eng

March 20, 2018 | Author: kallatis | Category: Databases, User Interface, Computer File, Personal Computers, Computer Hardware


Comments



Description

INFOSERVICETitle Rev Document Database and Language ISE_ACE_07003_ENG Update Rev 00 Date 07/02/2007 Reason/Modification Prima Emissione Issue Date 00 07/02/07 Author Approved S. Meneghel M. Dussin Subject: Database and Language Update In order to execute the language or database update, please ensure that the PC is correctly connected to the Konfort equipment as described in the sections 5.1.2 and 5.1.4. If the machine is a K610 or K650, set the external interface communicator in NORMAL position. If the machine is a K670, set the external interface communicator in NORM. Position. 1. Update Procedure Access to the service menu of the Konfort device. The display shows the masque indicated below (Figure 5.2.1). ENTER PASSWORD. ---- Figure 1 Service Menu Mask Insert the code “8278” and press Enter to confirm. In the display appears the following inscription (Figure 5.2.2). PC HANDSHAKE Figure 2 Mask in programming mode. The application window is shown in Figure 3. The application has four areas: two for enabling the upload.INFOSERVICE Title Document Rev Database and Language ISE_ACE_07003_ENG Update 00 Issue Date 07/02/07 Start the application “ACE Konfort 6x0 – Upload Application”1. Upload enabling Areas: a) DB upload If selected. . and two for parameters selection. By pressing the button Upload the update starts. d) COM serial port selection ( Choose the COM port) Allows you to choose the serial port to be used for the file transfer to the EEPROM. for example if you are using a serial-USB adaptor between the PC and the interface cable. The Option TX delay [cycles] has been provided for the cases in which a reduction of transmission speed of the information is required. Parameters Selection Areas: c) Language Group selection (Choose the group to upload) Allows the selection of the language group file to transfer to the EEPROM.Upload Application. 1 For every detail of this application. Please coordinate with the TEXA technical assistance service when using this function. it communicates to the device that one of the language files should be transferred to the Konfort machine storage. please refer to appendix B. it communicates to the device that the data DB of the car should be transferred to the Konfort machine storage. b) Language upload If selected. Figure 3 User interface ACE Konfort 6x0 application. CONT. through the COM 2 port. if the unit to update is a K670. Figure 4 Example of selection. set the application as in Figure 4 and press “Upload”. For example. in order to transfer both the cars DB and the languages group file2. The application informs the user about the Upload status by means of a scroll bar. Besides. During the transfer of the displayed files of the Konfort recharge station. PC HANDSHAKE WRITE EEPROM OK Figure 6 Confirmation mask of performed programming. . At the end of the transfer the message “OK” appears (Figure 6). the application transfers both the cars’ DB and the language group file with a single operation.INFOSERVICE Title Rev Document Database and Language ISE_ACE_07003_ENG Update 00 Issue Date 07/02/07 If both “DB Upload” and “Language Upload” are selected. also the auto diagnosis file is updated. PC HANDSHAKE WRITE EEPROM CONT. the message indicated below appears. Figure 5 Programming mask in progress. you should switch off the equipment and subsequently disconnect the programming interface or the serial cable used.INFOSERVICE Title Document Database and Language ISE_ACE_07003_ENG Update Rev 00 Issue Date 07/02/07 At the end of the update. 2 Possible problems during the use A. the application shows the following window. After pressing the Upload button. . The problem is generated because the selected serial port is not in the used PC. therefore. In order to proceed with the transfer you should select another port and then move the serial cable. This problem is generated because the files to transfer are not in the right directory. After pressing the Upload button. After pressing the Upload button. C. The problem is generated because the selected serial port is used by another application. check their position. In order to proceed with the transfer please select another port and consequently move the serial cable. Refer to the instructions manual for indication about the right procedure. the application shows the following window. The performed updates will be effective after the restart only. The application will go out of the execution- B. Remark: If the equipment has already been activated and a new database has been uploaded. the application shows the following window. During the file transfer to the Konfort 6x0 a bidirectional communication between the application and the Konfort itself is generated. It is necessary to check the serial connection. the application shows the following window. . The error shown underlines that the problem is generated because the application has received no answer after having sent a data segment.INFOSERVICE Title Rev Document Database and Language ISE_ACE_07003_ENG Update 00 Issue Date 07/02/07 D. After pressing the upload button.
Copyright © 2024 DOKUMEN.SITE Inc.