Hudson RCI Product Catalog

March 25, 2018 | Author: martyf777 | Category: Equipment, Medicine, Clinical Medicine, Wellness, Health Treatment


Comments



Description

For over half a century, Hudson RCI has offered one of the most extensive lines of highquality respiratory care and anesthesia products. Our reputation has been built on our commitment to finding solutions for the healthcare community and providing unparalleled customer support. As evidence of our ongoing commitment to quality, Hudson RCI is proud to be an ISO certified medical device manufacturer. Our dedication to the safety and well-being of patients and healthcare professionals was never more clear than when we became one of the first manufacturers to provide a nearly latex-free product offering, once again raising the standard for the industry. Many of the products featured in this catalog are names you have come to recognize and trust. Names such as CONCHATHERM® heated humidification systems, MICRO MIST® nebulizers, SHERIDAN® endotracheal tubes, VOLDYNE® incentive spirometers, HUMIDVENT® HMEs and more. This catalog is designed as a reference tool to provide the busy healthcare professional with pertinent product information. For your convenience, Hudson RCI has established an extensive network of distributors throughout the world, supported by our own team of sales professionals. To place an order, please contact your local distributor. For assistance in locating the distributor nearest you, for additional product information, or to contact your Hudson RCI Territory Sales Manager, call Customer Service or visit our web site at www.hudsonrci.com. *After 7/16/04 Telephone 909-676-5611 Toll Free 800-848-3766 951-676-5611 Fax General 909-676-1578 951-676-1578 Customer Service 909-695-9621 951-695-9621 Mailing Address HUDSON RCI 27711 Diaz Road P.O. Box 9020 Temecula, CA 92589-9020 Web Site www.hudsonrci.com *Effective July 17, 2004, the new area code will be 951. Table of Contents Masks, Cannulas & Tubing Oxygen Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Aerosol Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Cannulas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Infant Nasal CPAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Oxygen Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Aerosol Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Nebulizers Small Volume Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Large Volume Nebulizers & Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ultrasonic Nebulizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Unit Dose Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Humidification Bubble Humidifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Heated Humidifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Brackets & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 ConchaTherm 2000 CPAP Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Humid-Heat System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 HMEs, HCHs & Filters HMEs and HCHs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Trach HMEs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Flex Tube Combinations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Bacterial/Viral Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Ventilator Circuits & Accessories Adult Circuits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Pediatric Circuits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Neonatal Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Circuit Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Anesthesia Circuits & Accessories Adult Circuits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Pediatric Circuits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Single Limb Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Gas Sampling Lines & Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Air Cushion Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Airway Management Endotracheal Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Endotracheal Tube Exchangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Stylets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Resuscitation Bags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Oral Airways . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Emergency Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Adaptors & Miscellaneous Elbows & Wyes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Adaptors & Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Temperature Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Tees, MDI Adapters & Neonatal Adaptors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Venti-Comp & Aerosol Drainage Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Incentive Spirometers & MDI Chambers Incentive Spirometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 MDI Spacers & Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Peak Flow Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Monitors Oxygen Monitor & Analyzers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Sensors & Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Regulators & Cylinders Click-Style Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Conserving Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Diaphragm Style Regulators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Regulator & Cylinder Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Indexes & Notes Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Alpha Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Numerical Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Oxygen Masks Medium Concentration Masks Cat. No. 1040 Cat. No. 1035 Adult • Clear, soft vinyl for patient comfort and visual assessment • Adjustable nose clip assures comfortable fit • Complete with 7-ft. oxygen supply tubing Pediatric • Same as Cat. No. 1040 except pediatric size mask Masks, Cannulas & Tubing Masks are individually packaged 50 to a case Cat. No. 1048 Adult • Same as Cat. No. 1040 but without tubing Medium Concentration Masks - Elongated Cat. No. 1041 Cat. No. 1049 Cat. No. 1042 Adult • Under-the-chin design for excellent fit on wide range of face sizes • Clear, soft vinyl for patient comfort and visual assessment • Adjustable nose clip assures comfortable fit • Complete with 7-ft. oxygen supply tubing Adult • Same as Cat. No. 1041 but without tubing Pediatric • Same as Cat. No. 1041 except pediatric size mask Cat. No. 1930 Cat. No. 1050 Adult • Same as Cat. No. 1041 but with universal tubing connector • Attaches directly onto flowmeter eliminating need for an adaptor Pediatric • Same as Cat. No. 1042 but without tubing Masks are individually packaged 50 to a case High Concentration Masks Cat. No. 1009 Cat. No. 1000 Adult • Clear, soft vinyl for patient comfort and visual assessment • Adaptor swivels to accommodate patient position • Adjustable nose clip assures comfortable fit • 750mL reservoir bag • Complete with 7-ft. oxygen supply tubing Pediatric • Same as Cat. No. 1009 except pediatric size mask Masks are individually packaged 50 to a case 1 1060 but with universal tubing connector • Attaches directly onto flowmeter eliminating need for an adaptor Masks are individually packaged 50 to a case Masks are individually packaged 50 to a case . 1059 but without tubing Pediatric • Same as Cat. 1935 Adult • Same as Cat. 1011 Adult • Under-the-chin design for excellent fit on wide range of face sizes • Clear.with Safety Vent Cat. latexfree check valve prevents rebreathing and allows exhaled gas to escape • Adjustable nose clip assures comfortable fit • 750mL reservoir bag • Complete with 7-ft. soft vinyl for patient comfort and visual assessment • Adaptor swivels to accommodate patient position • Adjustable nose clip assures comfortable fit • 750mL reservoir bag • Complete with 7-ft. No. 1059 Cat.Oxygen Masks High Concentration Masks . No. No. oxygen supply tubing Pediatric • Same as Cat. No. 1936 Adult • Low-resistance. oxygen supply tubing Adult • Same as Cat. No. oxygen supply tubing Adult • Same as Cat. latexfree. 1007 except pediatric size mask Masks are individually packaged 50 to a case Nonrebreathing Masks . No. No. 1058 Adult • Low-resistance. No.Elongated Cat. No. No. 1059 except pediatric size mask Cat. 1007 Cat. 1059 but with universal tubing connector • Attaches directly onto flowmeter eliminating need for an adaptor Nonrebreathing Masks 2 Cat. No. 1069 Cat. No. check valve prevents rebreathing and allows exhaled gas to escape • Safety vent allows for entrainment of room air • Adjustable nose clip assures comfortable fit • 750mL reservoir bag • Complete with 7-ft. No. 1060 Cat. Cannulas & Tubing Masks are individually packaged 50 to a case Air Entrainment Masks Diluters MULTI-VENT ® Masks Cat. simple delivery of variable oxygen concentrations • Features six color-coded diluters: 24%. No. No. low. No. high humidity adaptor. No. No. No. 28% and 30% Cat. 40% and 50% Pediatric • Same as Cat. No. Air entrainment masks are individually packaged 50 to a case. 1940 Adult • Safe. 7-ft. 1089 Medium Concentration for 35%. 26%. and oxygen connector • Adjustable nose clip assures comfortable fit • 750mL reservoir bag Adult • Same as Cat. ™ SELECT-A-VENT Masks • Safe. 1088 but with universal tubing connector • Attaches directly onto flowmeter eliminating need for an adaptor Low Concentration for 24%.Three-In-One Masks Cat. simple delivery of variable oxygen concentrations • Each mask includes color-coded. No. nonrebreathing bag assembly. oxygen supply tubing Adult • Same as Cat. No. 1937 Adult • Three-in-one masks can be used as a medium concentration.and medium-concentration diluters • Locking ring secures flow setting • Includes adaptor for high humidity entrainment • Complete with 7-ft. 1061 but with STAR LUMEN tubing Masks. 1098 Cat. or nonrebreathing mask • Includes mask with latex-free flapper valve. 35%. 1061 Cat. 31%. 28%. No. oxygen supply tubing. No. 1096 Adult • Kit includes mask. high concentration. No. No. 1098 but with universal tubing connector Pediatric • Same as Cat. 1088 Cat. 40% and 50% • Diluters not sold separately • Includes adaptor for high humidity entrainment • Complete with 7-ft. 1943 Cat. 1098 except pediatric size mask 3 . 1088 except pediatric size mask Diluters are not sold separately. oxygen supply tubing Note: Use of oxygen concentrators with air entrainment masks will alter delivered FiO2 Cat. oxygen tubing and six color-coded diluters Adult • Same as Cat. D. 1095 but with 6-ft. 1083 Cat.D. soft vinyl for patient comfort • Adjustable nose clip assures comfortable fit • Specifically designed for aerosol therapy • Does not include tubing • Accepts 22mm I. 1095 Cat. aerosol tubing Pediatric • Same as Cat. 1385 Adult • Clear. 1085 Pediatric • Same as Cat. 1388 • For high-humidity aerosol therapy • Same as Cat.Elongated Cat. soft vinyl for patient comfort • Adjustable nose clip assures comfortable fit • Specifically designed for aerosol therapy • Does not include tubing • Accepts 22mm I. No. 1083 except pediatric size mask Masks are individually packaged 50 to a case Aerosol Masks Cat. No. No. No. No. soft vinyl offers patient comfort and ease of speech • Does not include tubing • Accepts 22mm I. aerosol tubing 4 Masks are individually packaged 50 to a case .D. No. 1084 Cat. No. 1080 Adult • Clear. No. 1084 except pediatric size mask Masks are individually packaged 50 to a case Face Tents Cat. No. No. 1083 but with 6-ft. No. corrugated tubing featuring cuttable sections every 6 inches Cat. aerosol tubing Adult • Same as Cat. corrugated tubing featuring cuttable sections every 6 inches • Distinctive under-thechin design made of clear.Aerosol Masks Aerosol Masks . 1100 Cat. 1075 Cat. oxygen supply tubing Pediatric • Same design as Cat. 1076 Adult • For tracheostomy and laryngectomy aerosol therapy • Tubing connector swivels 360 degrees for ease of positioning • 22mm O. connector accepts 22mm corrugated tubing and nebulizer tees Pediatric • Same as Cat. 1147 Cat. snug fit below the ears • Complete with 7-ft.Tracheostomy Masks Cat. No. 1101 Cat. 1075 except pediatric size mask Masks. 1102 Adult • Soft. No. oxygen supply tubing Elastic head strap cannulas are individually packaged 50 to a case 1102 5 . 1147 but 10 French • Individually packaged 50 to a case Elastic Head Strap Cannulas 1100 Cat. No. No. No. No. 1145 14 French • 16-inch flexible oxygen catheter made of smooth. pink-tinted vinyl • Adjustable elastic band for comfortable. snug fit below the ears • Complete with 7-ft. transparent vinyl • Adjustable elastic band for comfortable. No. No. No. No. 1100 but sized for pediatric patients Adult • Soft.D. Cannulas & Tubing Masks are individually packaged 50 to a case Oxygen Catheters & Cannulas Oxygen Catheters Cat. odorless material • Apertures are spaced to provide optimal patient comfort • Individually packaged 50 to a case 10 French • Same as Cat. . 1830 Adult 35 ft. 1838 Pediatric 7 ft. 1820 Adult 7 ft. No. 1817 Adult 14 ft. 1816 Adult 10 ft. 1831 Adult 50 ft. • Extremely lightweight and flexible • Anatomically designed to enhance patient comfort and acceptance • Over-the-ear design optimizes fit and stability while maximizing patient comfort • Available with standard or universal tubing connector which allows direct attachment to flowmeter • Most configurations include crush-proof and kinkproof tubing for continuous flow • Available without tubing • Cannulas individually packaged in case quantities listed below Cat. 1825 Adult 50 ft. 50 • • • • • • • • • • • • • • • • • • • • • 50 50 • • 50 50 50 • • 50 25 • • • 25 25 25 • 25 50 • • • • Cat. 1818 Adult 14 ft. 1819 Adult 7 ft. Size Tubing Length 1821 Adult None 1827 Adult 4 ft. 1837 Pediatric None 1826 Pediatric 7 ft.Nasal Cannulas Softech® Nasal Cannulas The Softech nasal cannula is produced by a special manufacturing process to provide an exceptionally soft cannula. 1822 Adult 7 ft. 1828 Infant 7 ft. STAR LUMEN Tubing Standard Tubing Standard Connector Case Qty. 1679 • Traps condensed moisture within oxygen supply tubing • Primarily used in conjunction with a nasal cannula 50 • Oxygen Tubing Water Trap 6 Universal Connector • Pliable tube resists cracking or breaking • Plug design minimizes potential for water leak • Individually packaged 10 to a case 50 50 50 50 Hudson RCI offers an extensive line of nasal oxygen cannulas to accommodate a variety of patient needs in all care settings. 1823 Adult 25 ft. No. 1824 Adult 25 ft. 1839 Pediatric 14 ft. 7 ft. oxygen tubing 7 . 14 ft.Nasal Cannulas Over-the-Ear Cannulas The popular Hudson RCI over-the-ear style cannula which has set the industry standard for decades is cost effective and offered in a wide range of adult configurations. Cannulas & Tubing • • • 50 50 Oxygen Conserving Cannula The Hudson RCI oxygen conserving cannula incorporates a patented “split prong” nare design and two oxygen supply tubes with standard connectors. • Design provides control and comfort in synchronizing breathing with oxygen conserving regulators. • • • • • • • • • 50 • • • • • 50 50 • None 50 50 25 25 50 • 7 ft. 2661 conserving regulator • Individually packaged 25 to a case Adult • Same as 1850 but with 7 ft. Masks. • Use of this cannula requires a conserving regulator with two ports. contoured lip tab provides a high level of stability and patient comfort • Over-the-ear design provides comfortable and secure fit • Offered with standard (nonflared) or flared nasal prongs • Available with standard or universal connector and standard or crush-proof STAR LUMEN® tubing in a variety of lengths • Cannulas individually packaged. 1109 1103 1920 1110 1921 1810 1812 1814 1108 1104 1111 Standard Nasal Tip Flared Nasal Tip • • • • • • • • Tubing Length STAR LUMEN Tubing Standard Tubing Standard Connector Universal Connector None • • 7 ft. Case Qty. 1850 Cat. case quantities are listed below Flared SOFTECH Cat. 25 ft. No. No. 50 ft. No. 1851 Adult Conserving Cannula • Oxygen conserving cannula with 5 feet standard oxygen supply tubing • Ideal for use with Cat. 7 ft. one for oxygen delivery and one for pressure sampling Delivers Oxygen Delivers Oxygen Senses Pressure Senses Pressure Cat. No. 50 7 ft. 7 ft. Standard • Flexible. No. 1843 Cat. CPAP Sets Sets are intended for use with mechanical ventilators and include: CPAP Systems Systems are designed for use with water seal or variable orifice CPAP generators and include: • • • • • • • • 8 Cannula Inspiratory elbow connector Expiratory elbow connector Knit cap Two 6-inch Velcro® sections Two 4-foot 10mm I.000 grams 3 15 1687 1693 > 3. anatomically curved prongs enhance fit and minimize nasal septal necrosis • Luer fitting on expiratory connector allows proximal airway pressure monitoring • Six prong sizes allow greater choice for appropriate sizing for each infant • Available in a “system’’ for use with water seal or variable orifice CPAP generator or in a “set” for use with most mechanical ventilators • Educational videotape “Infant Nasal Prong CPAP” available • Individually packaged 10 to a case The Hudson RCI Infant Nasal Prong CPAP cannula system is designed to reduce trauma associated with the delivery of infant nasal CPAP.2 years 5 20 1689 1695 Infant Weight Range .250 grams 1 12 1685 1691 1. CO2 sampling line with female luer connector PATENT NO.000 . 1845 • Cannula with 7-ft.836 Infant CPAP Cannulas Infant Nasal Prong CPAP Cannula • Soft.000 grams 4 16 1688 1694 1 . oxygen supply tubing and 7-ft. minimizing complications caused by deviated septa and occlusion.3. oxygen supply tubing and 7-ft. Set Cat. 5.1.250 .2. No. corrugated tubing sections 4-foot pressure monitoring line 22mm to 10mm humidifier adaptor • • • • • • Cannula Inspiratory elbow connector Expiratory elbow connector Knit cap Two 6-inch Velcro® sections Two 10mm to 7. • Available in three convenient adult configurations for use with any sidestream CO2 monitor to track respiratory rate and trend expired CO2 • Packaged with anesthesia machine adaptor • Individually packaged 25 to a case Softech BI-FLO cannula provides the capability of delivering supplemental oxygen while simultaneously sampling expired CO2 Cat. oxygen supply tubing and 3-in.5mm adaptors Suggested Cannula Size French Size System Cat. < 700 grams 0 10 1683 1690 700 . No. 1844 Cat.099.Sampling Cannulas Softech BI-FLO® Cannula The Bi-Flo cannula patented design allows delivery of oxygen to both nasal prongs and sampling of expired gases from both nares. CO2 sampling line with male luer connector • Cannula with 7-ft.D. No. No.000 grams 2 13 1686 1692 2. CO2 sampling line with female luer connector • Cannula with 7-ft. No. 15 50 ft. Cannulas & Tubing Hudson RCI pre-packed oxygen therapy kits include everything normally issued to a new home oxygen patient. 50 25 ft. and humidifier are individually packaged and labeled • Kits are packaged 10 to a case Oxygen Therapy Kit Contents Cannula with 7-feet Tubing Cat. 50 25 ft. 7 ft. 25 50 ft. • • • • • 1981 1983 1984 9000 9001 • • Universal Connector • • • • • 1927 Hudson RCI oxygen supply tubing is available in a variety of configurations to meet the needs of patients and clinicians in all care settings. • Bag is labeled with bar code. 25 9 . 5083 small nylon cylinder wrench Bilingual “No Smoking” sign (not sold separately) 1 6 2 1 1 1 1 Oxygen Supply Tubing Oxygen Tubing Configurations Cat. 50 25 ft. part number and list of contents. 25 25 ft. • All kits feature the Hudson RCI SOFTECH nasal cannula for maximum patient comfort • Cannulas. 25 30 ft. No. 2555 adaptor Cat. tubing. 1420 tubing connector Cat. 1982 • New! STAR LUMEN tubing is now available in a distinctive green tint color. 25 40 ft. 15 30 ft. 1950 4 1951 6 1952 6 1953 4 1954 2 Cannula without Tubing 25 ft. 50 14 ft. 25 50 ft. 25 14 ft. 50 7 ft. No. No. STAR LUMEN® Tubing 50 ft. Standard Tubing • 1112 1115 • • • • • 1119 1120 1124 1127 • 1928 1980 • Available with standard or universal connector which attaches directly onto flowmeter eliminating need for an adaptor.Oxygen Therapy Kits Masks. Standard Connector • • • • • • • • 1118 1925 STAR LUMEN ® Tubing Standard Green • • • • • • • Tubing Length Case Qty. No. • Distinctively designed STAR LUMEN tubing features a channeled inner lumen to resist kink and occlusion. STAR LUMEN Tubing 6 PSI Humidifier 2 1 2 1 Every kit also includes: (1) (1) (1) (1) Cat. 25 50 ft. 20 40 ft. 20 7 ft. packaged in a convenient drawstring bag. 18660 is constructed from DuPont Hytrel® polyester elastomer 10 Cat. 60 in. • • • 50 50 50 50 50 CORR-A-TUBE® . lightweight tubing available with cuttable cuffs every 6 inches (see chart) • Tapered cuffs securely attach to most 22mm respiratory therapy applications Cat. ease of handling and flexibility • Catalog No. convenient. No. Internal Diameter 22mm 22mm 22mm 22mm 22mm 22mm Case Qty. No. Length 1510 6 in. 1518 72 in.Reusable CORR-A-TUBE is clear. No. 24 in. Internal Diameter 22mm Case Qty. 1130 and 1132 are constructed from PVC and polypropylene • Catalog No. 1410 1413 1415 1416 1417 1418 Length 6 in. 50 50 50 50 50 50 CORR-A-FLEX® Tubing CORR-A-FLEX II 22mm disposable corrugated tubing available in popular precut lengths for convenience • Flexible. 22mm 22mm 50 2 Cat. 48 in. • No internal corrugates for condensate to collect in • Smooth interior offers quiet passage of airflow even at high flow rates • 22mm inside diameter adapts to most respiratory therapy applications Cat. 50 1132 18660 72 in. 1130 Length 48 in. 1528 72 in. 40 in. roll of 22mm corrugated tubing with cuttable 6-inch sections • Packaged in protective. Cuttable Cuff Case Qty. plasticlined dispenser box . lightweight tubing available in popular lengths. 60 in. 1680 • Continuous 100-ft. corrugated tubing augmented with spiral structural support designed to be cleaned and reused. • Provides durability. No. 72 in.Corrugated Tubing SMOOTH-FLO® CORR-A-TUBE® II Disposable. featuring a corrugated exterior with a smooth interior. 1516 48 in. 1517 60 in. No. No. ideal for home care applications. and 7 ft. 1888 • • • • • • • • • • • • • • • • • • • • • • MICRO MIST Nebulizer Kit. 1880 1881 1882 1883 1884 1885 1886 Nebulizer • • • • • • • Tee Mouthpiece Reservoir Tube 7 ft. • Optimal particle size delivered at efficient nebulization rates (MMAD = 2. It can be used for hand-held or in-line treatments. 1880 (2) Cat. simple to use. 1890 • Reservoir bag saves aerosol produced during exhalation for delivery on subsequent inhalation • Provides 50% more aerosol to the patient than a standard nebulizer tee with 6-inch reservoir tube • No effect on particle size generated by nebulizer • Cost-effective. No. 25 kits to a case AEROTEE™ Nebulizer System Cat. 2+2 Convenient kit. MICRO MIST nebulizer. 1883 • Packaged complete.Small Volume Nebulizers MICRO MIST® Nebulizer The MICRO MIST small volume nebulizer is designed for performance and economy and includes the design features needed by today’s respiratory care practitioners. oxygen supply tubing • Individually packaged 25 to a case 11 . • Each kit contains: (2) Cat. requires no adjustments • Includes AeroTee. Tubing Standard Connector Universal Connector Adult Mask (#1083) Nebulizers Ped. Mask (#1085) Cat. No. mouthpiece.1 microns) • Consistent performance at angles up to 90 degrees allowing medication delivery to patients positioned horizontally or with special requirements • Jet stays in place unless intentionally removed • Easy-seal. threaded cap and 8cc capacity anti-spill jar to prevent leakage • Available with standard or universal tubing connector • Individually packaged 50 to a case Cat. No. New Picture Required Cat. dense particles for specific site therapy • High-output.Small Volume Nebulizers UP-DRAFT II® PLUS Nebulizer The compact. 12 Aerosol Delivery Systems • Nebulizes at angles up to 45° to accommodate special treatment requirements • Easy-seal threaded cap and 8 cc capacity jar • Anti-spill design prevents loss of medication in any position • Jet stays in place unless intentionally removed • Available separately or with a variety of components • Available with standard or universal tubing connector • Individually packaged 50 to a case • .99% viral filtration efficient • Anti-spill UP-DRAFT II PLUS nebulizer produces fine. 1755 • Designed to reduce environmental contamination during aerosol therapy • Inspiratory and expiratory flow are isolated by latexfree one-way valves with exhalation directed through an efficient filter system • Electrostatically charged pathogen filter is proven* 99. Mask Universal (#1083) (#1085) Connector • • • ISO-NEB® Filtered Nebulizer System New Picture Required Cat. No. No. 1705 1706 1707 1730 1731 1732 1734 1737 Nebulizer • • • • • • • • Tee Mouthpiece • • • • • • • • Reservoir Tube • • 7 ft. high output UP-DRAFT II PLUS produces a concentrated mist at flow settings as low as 5 LPM with a minimal residual of medication.999% bacterial / 99. Tubing Standard Connector • • • • • • • • • • • Adult Mask (#1084) Adult Mask Ped. 8cc nebulizer operates vertically or at a 45 degree angle • Particle sizes range from 1 to 2 microns mean diameter* for optimum deposition • Individually packaged 20 to a case *Verified by independent laboratory tests. 1790 • Each kit includes one each — UP-DRAFT II® PLUS nebulizer — 12-inch 10mm corrugated tube — 22mm O.D.D.5mm connector — 10mm I.D. neonatal tee — 7-ft. Tubing • • • • • • Adult Mask (#1084) Adult Mask (#1083) Ped. x 10mm nebulizer adaptor — 10mm x 7. 1792 Neonatal Adaptor Kit • Same as 1790 but without nebulizer and oxygen tubing • 50 to a case 13 . No. circuits • Individually packaged 50 to a case Cat. x 10mm O. Mask (#1085) • • • Neonatal Nebulizer Kit Adaptor Kit Cat./18mm I.D. No. No. oxygen supply tubing • For administration of small volume nebulizer therapy during neonatal mechanical ventilation with 10mm I.Small Volume Nebulizers UP-DRAFT ® Nebulizer • High-output nebulizer available in a variety of configurations • Large capacity 15cc jar allows for aerosol treatments in excess of one hour • Available separately or with a variety of components • Individually packaged 50 to a case Nebulizers Cat.D. 1700 1710 1712 1713 1720 1724 Nebulizer • • • • • • Tee • • New Picture Required Mouthpiece • • Reservoir Tube 7 ft. 45% Saline 0.90% Saline 028 Adaptor 033 Adaptor 4 per case 10 per case • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 50 per case • • • • • • • • • 20 per case • • • • • • . 004-00 004-05 044-28 044-33 044-35 044-70 037-00 037-05 037-09 037-28 037-33 037-35 037-39 040-00 040-45 041-28 041-33 041-35 042-00 042-45 047-28 047-35 031-28 031-33 14 440 mL 760 mL 1070 mL 2200 mL • • • • • • Sterile Water 0.Large Volume Nebulizers AQUAPAK® Prefilled Reservoir and Nebulizer Adaptor Configurations Cat No. No. 1770 • Disposable nebulizer designed for use with clinician provided water • Delivers humidified gas in concentrations ranging from 28% to 98% • Lightweight. • Select from two precision nebulizer adaptors for delivery of a consistent aerosol over a wide range of oxygen concentrations • Two heater options provide heated aerosol therapy • Prefilled sterile reservoirs come in 4 convenient sizes. No. making the system truly versatile • See page 14 for configurations Nebulizers Nebulizer Adaptors Nebulizer adaptors designed for use with prefilled sterile reservoirs • Individually packaged 50 to a case Cat. 440mL. No. 760mL. adaptors and solutions to meet specific patient requirements efficiently and economically. easy to use • Bright yellow. Venturi-style entrainment ring with incremental dial for setting oxygen concentrations • Polypropylene jar holds up to 500cc of water • Clearly marked water levels • Individually packaged 50 to a case 15 . 1070mL and 2200mL • Available with both reservoir and sterile adaptor conveniently packaged together • Reservoirs may be used with other Hudson RCI humidification and nebulization products. Choose from a wide variety of reservoirs. 031-28 033 Adaptor (Blue) • Quiet venturi-style adaptor allows the selection of oxygen concentration from 33% to 98% 028 Adaptor (Yellow) • Venturi-style adaptor allows the selection of oxygen concentrations from 28% to 98% Large Volume Nebulizer Cat.Large Volume Nebulizers AQUAPAK® Prefilled Nebulizers Versatile. 031-33 Cat. sterile systems to provide cold or heated nebulization. No. as shown. No. A 9-10°C temperature drop will occur at the end of a 6 ft. hose. 1770 separately • Sold individually 16 . • Sold individually 1 As measured at the nebulizer elbow @ 8 LPM and full air entrainment.Large Volume Nebulizer Heaters AQUATHERM ® External Heater Cat. AQUATHERM III External Adjustable Electronic Heater Cat. 048-91 • Use with AQUAPAK prefilled nebulizer system to provide heated aerosol • Simple and reliable heater with a nonadjustable heater output • Provides aerosol temperatures between 35°C and 38°C1. Cat. 1770. No. 050-12 • Use with AQUAPAK prefilled nebulizer system to provide heated aerosol • Adjustable aerosol temperature to meet varying patient needs • Sold individually THERMAGARD ® Heater Cat. 5705 Designed for use with large volume nebulizer. No. • Provides continuous heated aerosol • Illuminated power switch and adjustable temperature range • Order Cat. No. 9% Saline (Red) Case Qty. 3 boxes to a case 1000 1000 • 1000 • • 1000 144 17 . System includes: • 2200mL sterile water reservoir • 150mL prefilled sterile water cup • Packaged 4 to a case Unit Dose Solutions ADDIPAK® Unit Dose Solutions • Tamper proof. 10 boxes to a case • 15mL vials packaged 48 to a box. No. color-coded vials for easy solution identification • Inverted milliliter graduations and precise opening for accurate and controlled dispensing of solution Cat. • Not for use in parenteral applications. half normal saline and full normal saline solutions • Packaged 24 to a case Cat. No. 051-45 Nebulizers Half Normal Saline 0. No. 1000 • 1000 • • Addipak unit dose vials are sterile solutions for inhalation therapy. 093-00 Prefilled long-term system provides continuous feed for both disposable and reusable ultrasonic reservoirs.45% Saline (Green) 0. 051-00 Cat. 051-90 Sterile Water Full Normal Saline 0. No.9% NaCL Cat.45% NaCL AQUAPAK Ultrasonic Systems Cat.Ultrasonic Nebulizer Products AQUAPAK® Ultrasonic Cups • Disposable. Size mL Sterile Water (Blue) 200-31 3mL • 200-34 3mL 200-39 3mL 200-51 5mL 200-54 5mL 200-59 5mL 200-69 15mL 0. No. prefilled 150mL cup produces highvolume aerosol mist for use in ultrasonic nebulizer treatment • Available in sterile water. • 3mL and 5mL vials packaged 100 to a box. No. No. 000-40 Humidifier Adaptor • Easy snap-off trigger design • Individually packaged 10 to a case • Humidifier adaptors incorporate audible alarm to alert clinician to flow restriction or occlusion of humidifier or tubing • Reservoir bottles have built-in oxygen tubing connectors AQUAPAK Silent Humidifiers AQUAPAK kits Provide sterile. 000-40 Humidifier Adaptor • Easy snap-off trigger design • Individually packaged 20 to a case • Use with Cat. 004-00 Cat. No. 003-01 Cat. No. 000-11 Silent Humidifier Adaptor • Audible alarm alerts clinician of flow restrictions or occlusion of tubing • Designed for use with Sterile Water Cat. 014-11 Cat. 037-00 440mL Sterile Water 760mL Sterile Water • Use with 000-11 • Individually packaged 20 to a case • Use with 000-11 • Individually packaged 10 to a case • 440mL Sterile Water • 000-11 Humidifier Adaptor • Individually packaged 20 to a case Cat. vibration or noise Cat. 017-11 • 760mL Sterile Water • 000-11 Humidifier Adaptor • Individually packaged 20 to a case . No. 006-40 AQUAPAK Kit AQUAPAK Kit • 340mL Sterile Water • 000-40 Humidifier Adaptor • Individually packaged 20 to a case • 650mL Sterile Water • 000-40 Humidifier Adaptor • Individually packaged 10 to a case Cat. 000-40 Humidifier Adaptor • Sterile. 006-01 340mL Sterile Water 650mL Sterile Water • Use with Cat. No. No. No. No. 004-00 or 037-00 • Individually packaged 50 to a case 18 AQUAPAK Prefilled Humidifiers combine an easy-to-use adaptor with choice of two sterile water reservoir bottle sizes. 003-01 or 006-01 sterile water • Individually packaged 120 to a case Cat. 003-40 Cat. No. No. Cat.AQUAPAK ® Bubble Humidifiers AQUAPAK Humidifiers The humidifier’s micro-diffuser produces smaller bubbles and greater surface agitation for quiet operation and high humidity output. Cat. silent humidification with no bubbles. No. No. No. clear adaptor body • Audible alarm alerts clinician of flow restriction or occlusion of oxygen cannula or mask tubing • Designed for use with Cat. 3130 Cat. Disposable Humidifier. No. durable plastic with preset audible alarm at 4 psi pressure relief • Unique diffuser designed to provide patient with comfortable. 3230 • Disposable. 6 psi Cat. No. No. therapeutic humidity and minimal noise • 500mL usable volume • Defined maximum and minimum water level lines • Recessed nipple reduces possibility of breaking off outlet connection • Individually packaged 50 to a case Humidification Reusable Humidifier Cat. therapeutic humidity and minimal noise • 500mL usable volume • Defined maximum and minimum water level lines • Recessed nipple reduces possibility of breaking off outlet connection • Individually packaged 50 to a case Hudson RCI offers a choice of Humidifiers for use with clinician’s water source. 6060 • Replacement Jar • Sold individually • Replacement Diffuser • Sold individually • Replacement Gasket • Package of 10 19 . durable plastic with preset audible alarm at 6 psi pressure relief • Allows the use of longer lengths of oxygen tubing without the audible alarm sounding • Unique diffuser designed to provide patient with comfortable. 3100 • Designed for long-lasting use and easy disassembly for cleaning • Specially treated connectors for maximum durability • Shatterproof. autoclavable and dishwasher-safe • 500mL usable volume • Distinct maximum and minimum water level lines • 2 psi audible pressure relief alarm • Sold individually Cat. 4 psi Cat. 3131 Cat. 3260 • Disposable. All feature audible pressure-relief valve to signal occlusion of the humidifier or tubing. No. No.Bubble Humidifiers Disposable Humidifier. No. • Adjustable Pause Mode allows selection of pause intervals from five to sixty minutes. and heated-wire disconnects • 120V. 20 Cat. 380-80R • For use with conventional circuits • Servo-controlled heater monitors and regulates heat output at the humidifier • Can be used with continuous flow or pressurized systems • Preset high. No. and adult patients • Can be used with conventional or 21-volt heatedwire circuits • Servo-controlled heater monitors and regulates the heat output at the humidifier • Bright. in five-minute increments • User-Selected Default Settings provide “customization” of airway temperature and temperature gradient values • Self-correcting high and low temperature alarms reduce occurrence of unnecessary audible alarms after the temperature normalizes • Expanded patient temperature option increases the upper temperature capability to 39°C in both the adult and infant modes The CONCHATHERM family of heated molecular humidifiers deliver optimal humidity and temperature to patients of all ages. No. 380-88R except with a 16-volt heated wire controller • For use with compatible 16-volt heated-wire or conventional neonatal and pediatric circuits. No. pediatric. 50 Hz Cat. 400-50 The CONCHATHERM IV Plus offers the proven performance and versatility of the CONCHATHERM IV Plus the additional features requested by clinicians. high/low temperatures.and lowtemperature alarms . but 230 V.CONCHATHERM® Heated Humidifiers CONCHATHERM® IV Plus Humidifier Cat. No. probe alarms. 60Hz • Same as 400-00. No. 50/60 Hz CONCHATHERM III ® CONCHATHERM III ® Plus Humidifier Cat. can be used with conventional or heatedwire circuits • Pause Mode for nebulizer treatments and circuit changes • Digital temperature display to a tenth of a degree • Advanced alarm package includes tracking alarms for patient temperature. but 100 V. No. 400-20 • Same as 400-00. 400-10 • Heated humidifier for use on infant. from neonatal to adult. No. 400-00R Cat. 380-88R • For use on infant. 380-90R • Same as Cat. CONCHATHERM IV Humidifier Cat. No. red digital temperature display with correlating high and low temperature audio/visual alarms Cat. pediatric and adult patients • Combines microprocessor technology with CONCHA-COLUMN® humidification system • 21-volt. CONCHATHERM® Products CONCHAPAK® Self-contained system for use with CONCHATHERM III, III Plus, IV, and IV Plus heaters includes sterile water reservoir and choice of standard, low-compliance or minimal compliance CONCHA-COLUMN. The convenient CONCHAPAK system includes sterile water and choice of CONCHA-COLUMN. • Safe, reliable gravity-feed system provides uninterrupted water flow • Evaporative process ensures minimal resistance to gas flow • Easy reservoir and column replacement • Standard and low compliance column available with two vertical or one vertical and one right-angle port • Minimal compliance column incorporates one vertical and one 45° port • Columns not sold separately • Columns individually packaged, sterile, case quantities vary, see chart below Cat No. 381-51 381-53 440 mL 760 mL 1650 mL Standard Column Low-Compliance Column • • 381-52 381-55 381-50 385-20 385-30 385-60 385-70 385-40 Vertical Ports Right-Angle Port Minimal Compliance Column Case Qty. 20 • • • • 6 Humidification 10 • • • • • • • • 6 6 • • • • • 6 • 6 • 6 • 6 • 6 CONCHA® Columns Standard Columns Minimal Compliance Column For use in most adult ventilatory applications. • Compressible volume: 103 mL when reservoir is full, 268 mL when reservoir is at replace mark Low-Compliance Columns Vertical Ports Right Angle Port For use in most applications requiring more constant compressible volume and compliance or CPAP applications with continuous gas flow < 50 LPM. • Compressible volume: 248mL + 12mL • Compliance: 0.25mL/cmH20 Minimal Compliance Column For use in applications requiring a low constant compressible volume and compliance. • Compressible volume is constant at 109mL • Compliance: 0.2mL/cmH20 • ISO 22mm connectors CONCHATHERM standard and lowcompliance columns are available with either vertical or rightangle ports. Minimal compliance column is available with a 45° angle port only and a built-in temperature monitoring port. Temperature probe port on the cap facilitates temperature control • Columns not sold separately 21 CONCHATHERM ® Accessories Temperature Probes Straight Tip Probe Right Angle Probe Designed to monitor airway temperature and signal high / low-temperature alarms. • High-accuracy, responsive thermistor probes are easily installed in ventilator circuit • Water-resistant probe connections fit snugly in-line for a tight seal • Sold individually 384-00 384-10 Cat. No. 380-93 Cat. No. 380-91 Cat. No. 380-92 Cat. No. 380-89 Cat. No. 384-00 Pediatric Thermistor Probe For use with CONCHATHERM III and conventional pediatric ventilator circuit. • 64 inches long • Straight-tip probe designed for smaller pediatric/neonatal wyes Pediatric DualThermistor Probe For use with CONCHATHERM III Plus, IV, IV Plus, and heatedwire ventilator circuit. • 64 inches long • Straight-tip proximal probe designed for smaller pediatric/ neonatal wyes Adult Thermistor Probe For use with CONCHATHERM III and conventional ventilator circuit. • 84 inches long • Right-angle proximal probe Adult Dual-Thermistor Probe CONCHATHERM Tubing Adaptor • Tapered fitting to 7mm • 15.5mm I.D. / 19mm O.D. • 30 to a case For use with CONCHATHERM III Plus, IV, and IV Plus. • 84 inches long • Right-angle proximal probe Cat. No. 380-89L • Same as 380-89, except 96 inches long Cat. No. 384-26 Cat. No. 388-28 Cat. No. 380-74 CONCHA Oxygen Diluter • When used with CONCHA humidifier, allows delivery of specific oxygen concentrations • Adjustable 26% to 90% • 30 to a case CONCHA Nebulizer Adaptor • When used with CONCHA humidifier, allows delivery of heated aerosol at specific oxygen concentrations • Adjustable 28% to 90% • 30 to a case Adult Probe Adaptor • Standard 22mm O.D. x 22mm I.D. connections • Port accepts CONCHA temperature probes • 24 to a case Cat. No. 384-10 CONCHATHERM Hose Adaptor • 5/16 in. barbed fitting • 15.5mm I.D. / 19mm O.D. • 30 to a case CONCHA® Mounting Brackets CONCHATHERM III and III Plus 386-72 386-81 386-10 386-76 386-40 Cat. No. 386-00 Cat. No. 386-65 Cat. No. 386-78 Cat. Nos. 380-00 and 380-10 Reservoir Bracket Bird 6400ST, 8400ST and VIP Ventilator Bracket Puritan-Bennett 2800 Ventilator Bracket Cat. No. 386-10 Cat. No. 386-77 Cat. No. 386-82 Universal Pole Mount Bracket BEAR 1, 2, and 3 Ventilator Bracket Puritan-Bennett 840 Ventilator Bracket Cat. No. 386-49 Cat. No. 386-72 Cat. No. 386-79 Infrasonics Adult STAR Mounting Plate Puritan-Bennett 7200 Ventilator Bracket Cat. No. 386-58 Cat. No. 386-73 CONCHA Mini Reservoir Bracket Cat. No. 386-75 Drager Evita 2 & 4 Ventilator Bracket Cat. No. 386-70 Hill Rom Rail Mounting Bracket Cat. No. 386-76 PB MA-1, MA-2, MA 2+2, Bear 5 and 1000 Ventilator Bracket LP6, LP10, PLV-100, PB COMPANION 2801 Ventilator Bracket Cat. No. 386-40 Wall Bracket 22 Siemens ADVENT, PB, Respironics Esprit Ventilator Bracket Cat. No. 386-81 Cat. Nos. 380-55, 380-80, 380-88 and 380-90 Reservoir Bracket CONCHA® Mounting Brackets CONCHATHERM® IV 386-09 386-53 386-74 386-71 386-51 Cat. No. 386-52 Cat. No. 386-63 Pole Mount • Extended Support Arm • Approximately 7.25 in. Bird 8400, T-Bird, and V.I.P., Sensormedics 3100A & B Ventilator Bracket Cat. No. 386-53 Cat. No. 386-64 DrägerEvita 2 and 4, Adult STAR Ventilator Bracket Bird 6400 and the V.I.P. Bird Ventilator Bracket Cat. No. 386-55 Cat. No. 386-69 Cat. No. 386-71 Wide Slide Bracket Assembly PB MA-1, MA-2, and MA2+2 Ventilator Bracket Puritan-Bennett 7200 Ventilator Bracket Cat. No. 386-56 Cat. No. 386-83 Cat. No. 386-54 Siemens Servo 300 Front Mount Cart Bracket Puritan-Bennett 840 Ventilator Bracket Infrasonics Infant STAR Pole Mount Cat. No. 386-57 Cat. No. 386-84 Siemens Servo 300 & 900 Side Rail Bracket Puritan-Bennett 740 & 760 Ventilator Bracket Cat. No. 386-50 Cat. No. 386-51 Cat. No. 386-66 Cat. No. 386-74 Pole Mount • Short Support Arm • Approximately 4.75 in. Bear 1, 2, 3 and 1000 Ventilator Bracket CONCHA Mini Reservoir Retrofit Kit (use with Bracket 386-79) Siemens i, Servo 300 and 900, Dräger Babylog Ventilator Side Rail Bracket Cat. No. 386-09 CONCHATHERM humidifiers have multiple mounting capabilities and can be used with a variety of accessories. Pole Clamp • Sold individually Humidification CPAP Humidification Products CONCHATHERM 2000 Designed to provide optimal humidification during mask CPAP and non-invasive ventilation. • Easy to use, easy to assemble system is user configurable • Basic system provides cold-passover humidity and can be upgraded with CONCHATHERM 2000 heater to provide heated humidification, if desired Cat. No. 500-10 Cat. No. 386-85 Basic Humidification Kit Includes components for cold-passover humidity • 500-20 Chamber - Single Patient Use • 500-50 Inlet Tube - Single Patient Use • 500-43 Foldable Stabilizing Tray CONCHATHERM 2000 Universal Pole Bracket • Sold individually Cat. No. 500-00 Cat. No. 500-50 Cat. No. 500-60 Inlet Tube • Single patient use • Sold individually Inlet Tube • Autoclavable • Sold individually Heated Humidifier • Features adjustable heater control, heater-on indicator and power-on indicator CONCHATHERM 2000 chambers and chamber replacement parts shown on page 24. Cat. No. 500-43 Foldable Stabilizing Tray • Provides stable platform for entire system • Folds for convenient storage • Sold individually 23 CPAP Humidification 500-30 CONCHATHERM ® 2000 Chambers Replacement Parts Specially designed, dishwasher safe, refillable chambers feature: Cat. No. 500-72 • Threaded, removable stainless steel base • Easy-fill port allows refilling without removal of tubing • Interchangeable with chamber for Fisher & Paykel ® HC 100 and HC 150 Chamber Housing • Single patient use • Sold individually Cat. No. 500-20 Chamber Housing • Autoclavable • Sold individually Chamber - Single Patient Use • Sold individually Cat. No. 500-73 Cat. No. 500-71 Cat. No. 500-30 Chamber - Autoclavable • Sold individually 500-20 Fill Port Plug • Sold individually Cat. No. 500-15 Replacement Gasket • Package of 2 HUMID-HEAT® System HUMID-HEAT System The microprocessor controlled Humid-Heat system delivers inspiratory gas at 37°C and 100% relative humidity at the patient airway. • For use on patients with 250 - 1500 mL tidal volumes and minute volumes of 3 - 30 LPM • Eliminates condensation in patient circuit and the need for heated wires, water traps and circuit sheaths Cat. No. 37101 Complete Humid-Heat System • Each system contains the following items: 1 1 5 20 10 1 1 1 Accessories Cat. No. Items 37184 Angular Clamp 1 37185 Mounting Pole 1 37187 Reservoir Holder 1 37180 Rail Clamp 10mm x 25mm 1 37182 Rail Clamp 10mm x 30mm 1 386-86 Bracket, PB 7200 Ventilator 1 386-91 Bracket, PB 840 Ventilator 1 386-87 Bracket, Slide Plate 1 386-89 Bracket, Viasys Ventilator 386-90 Bracket, Hamilton Galileo 24 Case Qty. Supply Unit, 120V Heater Temperature Probes A-HME Vented Water Feed Sets Angular Clamp Mounting Pole Reservoir Holder Cat. No. 37130 A-HME • Provides 30 mg H2O/L of inspired gas in passive mode, up to 44 mg H2O/L in active mode • 20 per case Cat. No. 37110 Supply Unit • Microprocessor control unit effectively regulates heat and water output • The only parameter that needs to be set is the patient minute volume • Sold individually Cat. No. 37160 Cat. No. 37152 Heater • Warms breathing gases at the patient airway • Sold individually Vented Water Feed Set • 10 per case 1 Cat. No. 37170 Cat. No. 381-51 1 Temperature Probe • 5 per case Sterile Water Reservoir • 440 mL • 20 per case No.6L 26.8 0. Vt = 0. SMOOTH-FLO ® tube with rigid patient connector • 17731 is provided sterile for head and neck surgery • Individually packaged.6L 26. 60 LPM 29 20 17731 HUMID-VENT 2S Flex Sterile 250 – 1500 29. • Recommended for tidal volumes between 150mL and 1500mL • Transparent housing provides excellent visibility • Very low resistance to flow • HUMID-VENT 2S Flex configurations include permanently attached 15mm I. case quantities listed below Offered in configurations to meet all patient size.4 0.2L 9.8.8.2L 11.9. connector Provides over 30 mgH2O/L @ Vt 20mL Only 2. 10011 11112 11132 • Recommended for tidal volumes between 50mL and 600mL • Offers low resistance to flow • Available in two configurations. in-line HME.4 0. Vt = 20mL 4. HCHs & Filters Moisture Output (mgH2O/L) Weight (grams) Resistance (cmH2O) Dead Space (mL) Case Qty. 15 – 50 30. 60 LPM 54 20 17732 HUMID-VENT 2S Flex 250 – 1500 29. bacteriostatic.D. the HUMID-VENT 1 is the original.3.8.5. case quantities listed below 17731/17732 Cat.6 0. tidal volume. and humidification needs.5.3. x 15mm O. Vt = 0. Vt = 0.8. microwell paper media provides optimal moisture output with low-flow resistance.6L 20. 60 LPM 29 20 14412 HUMID-VENT 2S 150 – 1500 28.5 0.6L 19. 10 LPM 2. single-use.9 0.HUMID-VENT® HUMID-VENT ® hygroscopic. Description TV Range (mL) 10011 HUMID-VENT Mini 11112 HMEs.4 0.4 30 HUMID-VENT 1 50 – 600 30. Vt = 0. with and without CO2 port • Individually packaged. Vt = 0. HUMID-VENT Mini Designed specifically for neonatal patients.D. 20 LPM 10 50 11132 HUMID-VENT 1 Port 50 – 600 30.4mLs of added dead space Only available sterile HUMID-VENT 1 With over 25 years of proven clinical experience. 60 LPM 54 20 25 . HUMID-VENT 2 13312 14412 The HUMID-VENT 2 is designed in both angled and straight versions for use in intensive care and anesthesia applications.D. 20 LPM 14 25 13312 HUMID-VENT 2 Port 150 – 1500 28. Vt = 0. • • • • Standard 15mm I. 99+% bacterial/viral efficiency HUMID-VENT Filter Small 18502 19502 11012 • Extremely small combined filter/HME for tidal volumes of 150mL . Straight 150 – 1000 30.0 2. 60 LPM 60 20 26 . 20 LPM 13. 60 LPM 35 25 18832 HUMID-VENT Filter Light. Description TV Range (mL) Moisture Output (mgH2O/L) Weight (grams) Resistance (cmH2O) Dead Space (mL) Case Qty.5L 22.9999% • Viral efficiency 99. 30 LPM 26 20 18402 HUMID-VENT Filter Compact. viral efficiency 99. Vt = 1. Angled 150 – 1000 30.99+% 18832 19932 Cat.1L 14.2L 30. 60 LPM 38 25 19402 HUMID-VENT Filter Compact.0 2.99% HUMID-VENT Filter Compact 18402 19402 • Mid-sized combined filter/HME for tidal volumes up to 1000mL • Only 38mL dead space with 30mg/L moisture output at 1000mL tidal volume • Bacterial efficiency 99. • Ideal for ICU and anesthesia use • Provides 99.9999%. Vt = .4.0. low resistance to flow and minimal deadspace • Individually packaged. case quantities listed below • Designed to accommodate tidal volumes from 250mL .8.2L 30.3 1.5L 21.0 2.Combined HUMID-VENT® HME / Filters Filter Pedi • Combined filter/HME for children 16-80 lbs. 60 LPM 60 20 19932 HUMID-VENT Filter Light. Angled 150 – 1000 30.1.8.9999%. Vt = 1.0L 32.0. Vt = 1. 11012 HUMID-VENT Filter Pedi 50 – 250 30. Vt = . Angled 250 – 1500 30. Vt = 0.0 20 18502 HUMID-VENT Filter Small.1000mL • Only 27mL dead space with 30mg/L moisture output at 500mL tidal volume • Bacterial efficiency 99.1500mL • Weighs only 30 grams • Two configurations to meet varying clinical needs of anesthesia and intensive care patients • 30mg/L moisture output at 1200mL tidal volume • Bacterial efficiency 99.5 1. Straight 150 – 1000 30. viral efficiency 99. Vt = 1. • Bi-directional filtration offers both patient and equipment protection from airborne pathogens • Available in a variety of sizes to meet all clinical situations • All units feature outstanding moisture output. Straight 250 – 1500 30. No.0 1.0 2. 30 LPM 27 20 19502 HUMID-VENT Filter Small.99+% HUMID-VENT Filter Light The HUMID-VENT combined filter/HME product line offers solutions to meet the needs of both anesthesia and intensive care.0L 31.1. allowing it to easily be removed and replaced during suctioning or change-out • OXY-VENT ® snaps over TRACH-VENT to allow delivery of supplemental oxygen The TRACH-VENT HME and accessory products are designed specifically for tracheostomized or intubated.VENT 1 Holder • Individually packaged 6 kits to a case Cat. No. Vt = 0. 45512 Cat. 45512 41112 61112 • For use on both pediatric and adult patients. No. No.0 grams with 10mL dead space • TRACH-VENT holder conveniently attaches TRACH-VENT to tracheostomy or endotracheal tube.5 0.25. 41172 TRACH-VENT HME OXY-VENT with Tubing Starter Kit • Individually packaged 50 to a case • Includes supplemental oxygen tubing and OXY-VENT adaptor • Individually packaged 10 to a case • Includes 3 TRACH-VENT HMEs 1 OXY. 30 LPM 10 50 HMEs. No.0 0. No.5L 4. HCHs & Filters 27 . Vt = 0. • Weighs only 4. 41312 • Compact. lightweight HME for spontaneously breathing patients • Includes convenient. self opening/closing suction port • Integral oxygen port allows delivery of supplemental oxygen when needed • Weighs only 6. 41112 TRACH-VENT >50mL 27. 41112 Cat. Description TV Range (mL) Moisture Output (mgH2O/L) Weight (grams) Resistance (cmH2O) Dead Space (mL) Case Qty. spontaneously breathing patients. 61112 TRACH-VENT Holder • Individually packaged 30 to a case TRACH-VENT+ HME Cat. Cat. 30 LPM 10 50 41312 TRACH-VENT+ >50mL 27. No.5L 6.25.5 grams • Individually packaged 50 to a case 41312 Cat.TRACH-VENT ® HMEs TRACH-VENT HME Recommended for tidal volumes of 50mL and above. 2.0 1. 20 20 • • 20 30 30 • 30 30 . 60 LPM 82 • 1578 AQUA+ FHY 350 – 1500 31. Description TV Range (mL) Moisture Output (mgH2O/L) Weight (grams) Resistance (cmH2O) 1570 AQUA+ Flex 300 – 1500 30. Vt = . minimal dead space and low resistance to flow.5L 5. case quantities listed below AQUA+ HCH incorporates the latest advances in material technology to provide optimal moisture output. Vt = .9.5L 11.5.7. Vt = .2. Vt = . Vt = . Vt = . 60 LPM 54 20 1571 AQUA+ 150 – 1000 28.6. cellular hygroscopically treated media.5L 13. Vt = . include built-in supplemental oxygen port • AQUA+ TS includes port for convenient suctioning • AQUA+ Flex one-piece construction with flexible tubing aids in patient positioning • AQUA+ N is ideal for neonate and infant patients • AQUA+ 1HS and AQUA+ are designed for most adult and pediatric applications • Individually packaged. • Integral gas sampling line holder included • Available in filtered and unfiltered versions • Individually packaged.AQUA+® HCHs AQUA+ HCH 1572 1571 1570 1574 AQUA+ HCH line utilizes a fiber-free. 1573 1589 AQUA+ Swivel HCH AQUA+ swivel allows 360 degrees of flexibility in positioning patient and HCH.0 1. No. 60 LPM 82 • 1579 AQUA+ HY 350 – 1500 30. designed for spontaneously breathing tracheostomy patients.5.5L 15.5L 48. • Available in filtered and unfiltered versions • Includes integral gas sampling port and sampling line holder • AQUA+ FHY and HY incorporate built-in patient wye 1575/1576 1578/1579 AQUA+ 1-2-3 All versions have angled patient connections and include a CO2 monitoring port to eliminate the need for separate gas sampling elbow.5L 5.0 1. Vt = .0 2.5L 16. minimizing torque. 60 LPM 82 • 20 1581 AQUA+ 1 H 200 – 1400 30.25L 13. Vt = .5L 33.9.6. 60 LPM 15 30 1575 AQUA+ FH 350 – 1500 31. Vt = 25mL 3.5L 14.0 2.5L 34. Vt = .7. 15 LPM 2 50 1573 AQUA+ T 75 – 1000 24.0 2. 60 LPM 31 • 30 1582 AQUA+ 2FH 100 – 500 30.5 1. • AQUA+ T and TS models. 60 LPM 15 30 1574 AQUA+ TS 75 – 1000 24.0 2.5 0.0 0.5 0.9.0 0.0 1. and is available in a variety of configurations to meet a wide range of clinical needs. 30 LPM 24 • 1583 AQUA+ 2H 100 – 800 29. 60 LPM 82 • 1576 AQUA+ H 350 – 1500 30. Vt = .5L 49. Vt = .8. 30 LPM 20 • 1589 AQUA+ 1HS 200 – 1400 30.8. 60 LPM 24 • 1584 AQUA+ 3FH 80 – 400 29. 60 LPM 28 28 Dead Space (mL) Sampling Port Filter • Case Qty.25L 12. 60 LPM 24 30 1572 AQUA+ N 10 – 50 30.6. case quantities listed below 1582/1583 1581 Cat. Vt = .0 1. C. and anesthesia settings. No. No. rigid connectors on ends 30mL dead space Individually packaged 20 to a case EXPANDI Flex™ Hudson RCI offers a Flex Tube to meet every clinical need in the I. Flex Tube Cat. No.D. 22362 22362 • Lightweight positionable flex tube with rigid connectors • 15mm I. 95mm . ideal for head and neck surgery 15mm I.Flex Tubes and HME Combinations SMOOTH-FLO® Flex Cat. x 15mm O. No. 1800404 • Same tube as above but with rigid 15mm I. No.U. connectors • Adjustable length. 1590 19932-BKH G1441-BKH 19402-BKH • Each combination inlcudes one HME and one flex tube • See chart for available combinations and case quantities • All configurations individually packaged Cat.D. 30mL expanded • Individually packaged 25 to a case SOFTFLEXTM Cat. HME Cat. x 15mm I. HCHs & Filters Flex Tube / HME Combinations A wide variety of convenient prepackaged flex tube/ HME combinations are available to meet every humidification and patient need.D. Case Qty. tubing connectors 31mL dead space Packaged 100 to a case (10 bags of 10) SOFTFLEX with Rigid Connector Cat. Flex tube is ideal as an interface between the patient and circuit/ HME. 1800402 • • • • 1800402 Extremely light and flexible tube 22mm I.D. patient connector • Packaged 100 to a case (10 bags of 10) 1800404 HMEs.155mm • Dead space is 14mL collapsed. No. 1590 1800402 1589 30 G1441-BKH 1800402 14412 20 19932-BKH 1800402 19932 20 19402-BKH 1800402 19402 25 29 .D. No.D. Cat. 20011 • • • • 20011 Supplied sterile. x 15mm O.D. D.D. low dead space housing design for maximum patient and staff comfort 28052 28062 Cat. 28022 has 22mm I.D./15mm I. HEPA Class 13 • Smooth.D. No. see below for case quantities . connectors • Cat.8. highly hydrophobic bacterial/viral filter . dead space 26mL Resistance 2. 19212 ISO-GARD Depth Filter Hydrophobic. proven bi-directional bacterial/viral filtration media used in the larger HEPA Light models.0 80 20 28012 Hepa Light 300 – 1200 25.D. Vt = . 60 LPM Individually packaged 25 to a case Dead Space (mL) Case Qty.D. No. No.D. viral efficiency 99.3 29 25 Cat./15mm O.5L 34 1. electrostatic bacterial/viral filter for use on patient end of circuit when HME is not required • • • • • 30 22 mm I. Description TV Range (mL) Moisture Output (mgH2O/L) Weight (grams) Resistance (cmH2O) 28002 Hepa Light w/Port 300 – 1200 25.D.Hepa Class 13 • May be used as an HME (see moisture output on chart) • Bacterial/viral filtration efficiency of 99.7. x 22mm O. equipment and caregiver. transparent. x 22 mm O. lightweight.ISO-GARD® Filters ISO-GARD Hepa Light 28012 • ISO-GARD Hepa Light is an advanced. Straight 150 – 800 25. x 22mm O. connectors • Cat.D.6 80 20 28052 HEPA Small.3 31 25 28062 HEPA Small. 28002 includes gas sampling port with 22mm I. Vt = .0 80 20 28022 Hepa Light 300 – 1200 25.25L 23 2.99+% Weight 22 grams.8.D. Vt = . Bacterial efficiency 99. 28012 has 22mm I.9999%. connectors. No.D. x 22mm O.9999+% • True hydrophobic HEPA filter. Angled 150 – 800 25./15mm I.0cm H2O.D./15mm O.25L 23 2. Vt = .D./15 mm O.D. • High-level filtration protection while conserving patient exhaled heat and humidity (see moisture output on chart) • For use with adult and pediatric patients in anesthesia applications • Bacterial/viral filtration efficiency: 99.5L 37 2.9999+% • Cat. ideal for machine filtration applications 28022 28002 ISO-GARD HEPA Small Utilizes the same./15mm I. at half the size.5L 38 2. No. Vt = ./15mm I.D. • Suitable for use on pediatric to adult patients • Individually packaged. ISO-GARD HEPA and Depth Filter Systems offer bidirectional bacterial/ viral filtration for cross-contamination protection of patient. /22mm O. @ 8 LPM flow Individually packaged 50 to a case AQUA+ F Bacterial / Viral Filter Cat.999+%./22mm O. • • • • • 15mm I. 1577 For adult applications where a filter is desired between the patient and circuit.D.19 cmH2O/L/Sec.D. No.99+% Dead space is 42mL Flow resistance approx. HCHs & Filters Ventilator Main Line Filter Kit Cat.D. patient connection Tidal volumes from 350 . No. No. tubing and adaptor to accommodate most ventilator setups • Individually packaged 30 to a case 31 .D. 1. viral efficiency 99.5 cmH2O at 60 LPM Individually packaged 50 to a case Pulmonary Function Bacterial/Viral Filter Disposable Bacterial/ Viral Filters to address a wide variety of clinical applications.1605 main flow filter. x 30mm O. Cat.D. Bacterial efficiency 99. 130mL compressible volume Flow resistance . x 15mm I. these filters utilize a nonconductive.9+ bacterial/viral efficiency Includes integral gas sampling port 360° swivel design aids positioning and minimizes torque • Individually packaged 20 to a case HMEs.Filters Main Flow Bacterial/Viral Filter 1603 Cat.D. • Convenient configuration incorporates Cat.1500mL 99. 1603 • • • • 30mm I. naturally hydrophobic filter media. 1605 • • • • • 1605 22mm I. No.D. No. 1606 Main line filter kit is used to connect main flow supply from ventilator to a heated humidifier. 1614 / 1615 Cat. No. I. materials and styles. No. but with AVA-NEB small volume nebulizer Cat. made of Kraton Cat. No. Nos. 1619 • Same as 1609. 1608 • Standard ventilator circuit • Straight connector inspiratory limb (For use with HMEs only) • Standard ventilator circuit • Includes humidifier limb Hudson RCI Adult Ventilator Circuits are available in a variety of configurations. No. 1615 is 60 inches long • Same as 1617. 1607 Cat. pressure monitoring tubing • Includes humidifier limb • Same as 1627. made of Kraton Cat. No. except as noted • Individually packaged 10 to a case. 1643 Exhalation Valve • Includes exhalation valve. 690-50 • Same as 1627. 1610.D. No. 690-30 • Same as 1619. No. 1608. No. No. pressure monitoring tubing and separate water traps Cat. 1609 Cat. No. No. and 1/4 in. Cat. 1614 is 48 inches long • Cat. made of Kraton Adult Conventional Circuits with Exhalation Valves Cat.Adult Conventional Circuits • Adult ventilator circuits incorporate standard 22mm connections for use with a variety of ventilators • All adult conventional circuits are 72 inches long. but without humidifier limb Cat. 1613 • Same as Cat. No. but without humidifier limb • Cat. exhalation valve tubing and tubing hanger • 50 per case 32 . but without humidifier limb Cat. 1610 • Circuit with 1/4 in. 1617 • Circuit with in-line water traps • Includes humidifier limb • Circuit with 1/8 in. but without water traps • Choose conventional or heated-wire circuits with 22mm blue polyethylene or KRATON® tubing • Ported wyes allow pressure sensing and temperature monitoring and include tethered caps for plugging ports Cat. No. No. 690-40 • Same as 1613. No. 1625 Cat. No. 1627 • Same as Cat. except as noted Cat. No. 780-20 • Single-heated limb circuit accessory • Includes humidifier limb and separate temperature probe adaptor • Can be used for oxyhood set-ups • Individually packaged 20 to a case • Single-heated limb circuit accessory with separate temperature probe adaptor • Can be used for oxyhood set-ups • Individually packaged 20 to a case 33 . except as noted Cat. No. 780-32 Cat. 790-32 • Standard circuit with 1/8 in. • All adult heated-wire circuits are 60-inches long • Individually packaged 10 to a case. 780-36 • Circuit with dual-heated limbs • Includes humidifier limb • Circuit with dual-heated limbs • Water traps assembled in both limbs • Includes humidifier limb Ventilator Circuits & Accessories Cat. No. No. I. 780-31 Cat. 780-33 Cat. No. 780-34 • Circuit with heated inspiratory limb • Expiratory limb water trap • Includes humidifier limb • Circuit with heated inspiratory limb • Water traps assembled in both limbs • Includes humidifier limb Adult Heated-Wire Circuits are designed specifically for use with CONCHATHERM III ® Plus (21-volt) and CONCHATHERM ® IV. No. and 1/4 in. No.D.Adult Heated-Wire Circuits Cat. and IV Plus heated humidifiers. made of Kraton Cat.D. pressure monitoring tubing • Heated inspiratory limb • Standard circuit with 1/8 in. 780-19 Cat. pressure monitoring tubing • Dual heated limbs • Same as 780-32. No. 780-35 Cat. and 1/4 in. No. No. I. 2. A. 7200 (early models) • • • • • • 780-32. 690-50 34 • • • • • • • • • • • • • • • • • • • • • • • • • • Siemens Servo 900 A. Savina • • • • • • • • Newport Wave Engstrom Erica • • • • • • • • Monaghan 225 Emerson • • • • • • • • Infrasonics Adult STAR Bird 8400ST • • • • • • • • • • 1607. No. 2+2. Evita 2 & 4. AE. C. 1000 Cat. 780-20 • • • • • • • • • • 780-31 780-51 • • • • • • • • Newport Breeze E-150. Amadeus. Bear 1. 760. 300. 1613 1614. 690-30 1610. 780-51 • Circuit with external exhalation valve • 1/4 in. No. Galileo. SPE. Raphael Bird 6400ST Bear 5. 1615 690-40 780-33. 3 Adult Ventilator Circuit Reference Chart • • • • • • . B.Adult Heated-Wire Circuits Cat. 840 • • • • • • • • • • • • • • • • • • • • • • • • • • • • PB MA-1. i PB 7200. 740. 2. 790-32 780-19. 1625 1627. E. 780-34 780-35. 780-36 • • 1617 1619. E-100i Drager. monitoring tubing • Heated inspiratory limb 1609. 1608 Hamilton Veolar. except as noted • Individually packaged 20 to a case. except as noted • Individually packaged 20 to a case. except as noted Cat. 780-30 Cat. and incorporate standard 15mm and 22mm connectors • Ported wyes allow pressure and temperature monitoring and include tethered caps for plugging ports when not in use Pediatric Heated-Wire Circuits • All heated-wire circuits are 60 inches long. include two pressure lines. 780-22 • Standard pediatric circuit • Includes humidifier limb • Standard pediatric circuit • Two separate water traps (one shown) • Includes humidifier limb Pediatric Ventilator Circuits are available in a variety of configurations and styles. No. except as noted Cat. No. 780-23 Cat. 780-21 Cat. 780-24 • • • • • 21-volt • Circuit with dual-heated limbs • Includes humidifier limb 21-volt Circuit with heated inspiratory limb Separate water trap Includes humidifier limb Pediatric Heated-Wire Circuits are designed specifically for use with CONCHATHERM III ® Plus (16-volt and 21-volt) and CONCHATHERM ® IV and IV Plus (21-volt) heated humidifiers. No. No. No. No. Ventilator Circuits & Accessories Cat. • Circuits utilize 15mm tubing. 780-25 • 21-volt • 15mm single-heated limb circuit • Can be used for oxygen hood set ups and in the operating room • • • • 16-volt Circuit with dual-heated limbs Includes humidifier limb 48-inches long 35 .Pediatric Conventional Circuits • All pediatric conventional circuits are 60 inches long. No. 780-02 Cat. No. No. materials and styles. 780-12 • Standard neonatal circuit with assembled water traps • Proximal and 18-inch remote temperature ports Neonatal Heated-Wire Circuits Cat. . No. 780-11 • Standard neonatal ventilator circuit with proximal temperature port and separate water traps • Standard neonatal ventilator circuit with proximal and 18-inch remote temperature ports and separate water traps Neonatal Ventilator Circuits are available in a variety of configurations.Neonatal Conventional Circuits • All neonatal ventilator circuits are 48 inches long. and incorporate standard 15mm and 22mm connectors • Ported wyes allow pressure and temperature monitoring and include tethered caps for plugging ports when not in use • Conventional and heated-wire circuits are available with or without water traps Cat. No. 780-10 Cat. 780-03 • 16-volt • Circuit with heated inspiratory limb • Proximal and 12-inch remote temperature ports • 16-volt • Circuit with dual-heated limbs Cat. except as noted • All neonatal circuits include a humidifier limb • Packaged 20 to a case Cat. 780-06 • 21-volt • Circuit with heated inspiratory limb • Proximal and 18-inch remote temperature port 36 Neonatal Heated-Wire Circuits are designed specifically for use with CONCHATHERM III ® Plus (16-volt and 21-volt) and CONCHATHERM ® IV and IV Plus (21-volt) heated humidification systems. • Circuits utilize 10mm tubing. No. include two pressure lines. No. 780-40 Cat. 780-14 • 21-volt • Circuit with heated inspiratory limb and expiratory water trap • Proximal and 18-inch remote temperature ports • • • • 21-volt Circuit with heated inspiratory limb Proximal and 18-inch remote temperature ports Assembled water traps in both limbs SMOOTH-FLO® Circuits The SMOOTH-FLO circuit and minimal compliance column enhance humidification and gas delivery to infants and neonates in all traditional modes of ventilation. No. No. No. 780-15 • 21-volt • Same as 780-14. 780-42 Cat. 780-13 Cat. 780-43 • Circuit with dual heated limbs and proximal temperature port • Circuit with dual heated limbs • Proximal and 18-inch remote temperature ports Ventilator Circuits & Accessories The SMOOTH-FLO circuit and minimal compliance column is a unique ventilator system designed specifically for infants and neonates. but with proximal and 18-inch remote temperature ports Cat. No. No. low compressible volume. 37 . proximal and 18-inch remote temperature ports • Water trap assembled in expiratory limb Cat.Neonatal Heated-Wire Circuits Cat.D. low resistance to gas flow and improved humidity • Incorporates swivel patient connector to lessen torque at airway • SEE-THRU® smooth bore tubing • Patented 15mm I. 780-07 Cat. expiratory limb decreases resistance to flow • Includes humidifier limb • Individually packaged 20 to a case Cat. No. 780-41 • Circuit with heated inspiratory limb and proximal temperature port • Water trap assembled in expiratory limb • Circuit with heated inspiratory limb. No. but dual-heated limbs Cat. but with proximal and 18-inch remote temperature ports Cat. No. 780-04 • 16-volt • Circuit with dual-heated limbs • Proximal and 12-inch remote temperature ports • 21-volt • Same as 780-04. 780-05 • 16-volt • Same as 780-04. No. • 21-volt • Minimal deadspace. an anti-suffocation valve and 7 feet oxygen supply tubing • Individually packaged 15 to a case • This product contains natural latex rubber Cat. Circuit Cat.Ventilator Circuit Accessories Home Care / Portable Ventilator Circuit Cat. No. 1696 Universal single-limb ventilator circuit may be used with Aequitron LP-series ventilators.M. 6 in. No. System • Includes a humidifier manifold. exhalation valve line. • Complete with main circuit hose. patient elbow connector. two one-way valves • 50 to a case I.P. 1667 Ventilator Monitoring Adaptor Circuit • Used for obtaining ventilation parameters • Includes 6 in.M. tee.B. No. but without reservoir bag and oxygen tubing • Individually packaged 15 to a case Universal I.V. and exhalation valve and nebulizer drivelines • Individually packaged 50 to a case Cat. 1652 Complete I. CORR-AFLEX ® tubing. oxygen inlet. exhalation valve manifold. Puritan-Bennett Achieva ® and Companion ® 2800 and 2801 ventilators and Bear ® 33 ventilator. multiple adaptor kit.P. No.B.V.P. mouthpiece. aerosol hose. machines • Sensitive exhalation valve with clear cap for accurate view of valve function • Expiratory flow diverter directs gas away from therapist and patient • Complete with high-output nebulizer with 20mL jar capacity. aerosol tee and 6 in. nipple adaptor. tube. No. reservoir manifold.M. System • Same as 1652.V. Systems Cat. 1560 • Suitable for use with all I.P. 15mm/ 22mm adaptor. and humidifier limb • Green exhalation valve and clear cap allow for easy visualization of valve function • Color-coded pressure line (blue) and exhalation line (clear) • Individually packaged 15 to a case Cat. 1668 Trache Tee Oxygenator • Includes oxygen nipple adaptor. 3 liter reservoir bag. CORR-AFLEX tube • Individually packaged 50 to a case 38 . LifeCare PLV ®-100 and PLV ®-102 ventilators. No. 1654 Basic I. and 39 in. proximal airway pressure line. No. and CPRAM configurations Hudson RCI’s Disposable Anesthesia Breathing Circuits meet ISO and ASTM standards and include a wide range of features.) Mask Gas Sampling (Cat.) Line B 10’ M/M 11112 1 19402 15810 • • 3LF 19402 30600219 24”–82” 3 19402 15808 B 10’ M/M 352483 24”–82” 3 19402 15810 B 10’ M/M 352583 24”–82” 3 19402 352513 40”–96” 3LF 2 3 1 LF denotes latex-free breathing bags • • • • • B 10’ w / . No. Adult Swivel Wye Circuits • Either leg of swivel wye articulates to correctly position tubing • Available with or without ports on wye plus gas sampling or plain patient elbows • Offered with standard or expandable 22mm tubing Cat. easy-drape tubing made with consistent wall thickness and free of pinhole leaks • Clear.8µ 26”–72” 3020002605 24”–82” Gas Sampling Quantity Port on Wye Elbow Case B 10’ M/M B 10’ M/M – 30 – 30 GS 30 – 30 GS 20 GS 20 – 20 – 20 – 20 GS 20 P 30 GS 30 P 20 • • P 20 P 20 GS 30 • GS 20 B 8’ M/M Anesthesia Circuits & Accessories 39 . No. Mapleson D. Hose Length Bag (Liter) Filter 3 1 16020 40” 170232-970 40” 30600112 40” 3 1 3040003043 40” 3LF 1 352103 40” 3 352113 40” 3 30600400 48” 3LF 16320 72” 16322 72” 2 7147 26”–72” 3 (textured) 3020004110 26”–72” 2 (textured) 30600263 HCH (Cat. Bain. hard plastic parts for optimum viewing maintain dimensions when exposed to heat and humidity • Gas sampling elbow with 90° angle to prevent line kinking and 360° swivel for correct and torque-free positioning • Near parallel fixed wye available in adult and pediatric configurations • Premium adult swivel wye available with and without ports to address specialized circuit placement needs • Nonrebreathing single-limb systems available in modified Jackson Rees.Anesthesia Breathing Circuits Anesthesia Breathing Circuits • Soft. No. Filter Extension Detachable HCH Mask Hose Limb (Cat.) (Cat.8µ GS/Tip 30 1589 B 10’ w/. No. No.Adult Fixed Wye Circuits Hose Length Bag (Liter) 16003-579 40” 3 16003-944 40” 3 16003-951 40” 3 16003-957 40” 3 16010 40” 170032-596 40” 3 1 170032-951 40” 3 1 350153 40” 3 350163 40” 3 351100 40” 351102 40” 351103 40” 351112 40” 2 351113 40” 3 2 Cat. Port 13312 RSC • 11112 1 1 Quantity Case – 30 P 30 GS 30 P 30 P 30 GS 30 GS 30 GS 20 GS 20 20 2 GS 20 3 GS 20 1 GS 20 1 GS 20 40” 3 351133 40” 3 356113 40” 3 1R 357113 40” 3 1 358103 40” 3 359103 40” 3LF 391103 40” 3 391113 40” 3 359113 40” 3LF 371103 40” 3 1 Elbow GS 351123 1581 • 1 1281 15808 • • 1R 1 371113 40” 3 371193 40” 3 377143 40” 3 1 3020002495 40” 3 2 1 1589 1581 1281 1 3020002670 40” 2LF 3020003564 40” 3 (textured) 1 3020003635 40” 3 1L 2 3020004414 40” 2 2 2 3030002513 40” 2 3030003837 40” 3LF 3040000630 40” 3 2 3040001506 40” 3 2 • 20 GS 20 GS 20 GS 20 GS 20 GS 20 GS 20 GS 20 B 10’ M/M GS 20 B 10’ M/M GS 20 B 10’ M/M GS 20 B 10’ M/M – 20 E 10’ M/F GS 30 GS 30 GS 30 30 RSC P 30 CSL P 30 15808 P 30 15808 GS 30 GS 30 P 30 CSL – 30 B 10’ M/F GS 30 40” 3 1 3040004660 40” 3 2 14412 15808 3040005166 40” 3 (textured) 1 13312 3040005432 40” 3LF 2 11112 15808 3050005201 40” 13312 15808 30600060 40” 3 LF 2 30600070 40” 3 LF 1 30600099 40” 3 1 30600207 40” 3LF 30600241 40” 3LF 30600375 40” 3 D 10’ M/M • 30 • B 10’ M/F • • 11112 2 • 1589 20 – P 40” 3 (textured) w/suction tubing & yankauer GS GS 3040002162 40 Port on Wye D 10’ M/M • – 30 GS 30 P 30 15808 B 10’ M/M GS 30 15810 B 10’ w/.) Sampling Line Temp.8µ GS 30 19932 RSC P 30 . Adult Fixed Wye Circuits Cat. Anesthesia Circuits & Accessories 41 . that may possibly result in an allergic reaction. No. No. Port Elbow Quantity Case GS 20 40” GS 20 40” GS 20 40” GS 20 GS 20 GS 20 GS 20 GS 20 GS 20 GS 20 GS 20 GS 20 1 • 1 1281 • • 391213 60” 3 1R 3020002432 60” 3 1 3020002861 60” 3 3020004750 60” 2 3040005345 60” 3 11112 3040005374 60” 3LF 19402 3040005539 60” 3LF 3040005561 60” 3LF 3040005666 60” 3LF 3050005289 60” 3 30600037 60” 3 30600127 60” 3 30600135 60” 3 1 30600143 60” 3LF 1 HEPA P 20 B 10’ M/M GS 20 CSL – 20 RSC P 20 GS 20 P 20 • 1 15808 GS 20 1 15810 GS 20 1 15810 1 w/suction tubing & yankauer 14412 15810 1 30600258 60” 3LF 1 16303-944 72” 3 72” 3LF 3040005609 72” 3 30600120 72” 3 30600271 72” 351600 96” B 10’ w/5µ 19932 1 1 3030003839 20 20 2LF 3 20 20 2LF 3 P GS P 60” 72” 20 20 GS 60” 72” • GS GS 15810 30600246 3020004609 E 10’ M/F 2 30600173 16303-951 2 RSC P 20 20 B 10’ M/M GS 20 B 10’ M/M GS 20 2 15810 13312 • 1 40” E 10’ M/F CSL 2 15808 • 20 20 GS 15808 96” P GS • P 20 P 20 13312 – 20 1578 – 20 GS 20 NOTE: Circuits with no breathing bag or LF breathing bag are LATEX FREE. No. Breathing bags in all other circuits contain natural latex rubber.) (Cat. Hose Length Bag (Liter) Filter 7140 48” 3 311203 60” 3 318200 60” 318202 60” 351200 60” 351202 60” 2 351203 60” 3 351213 60” 3 351223 60” 3 2 356213 60” 3 1R 357203 60” 3 391203 60” 3 Extension Detachable HCH Mask Hose Limb (Cat.) 2 Port on Wye Sampling Line Temp. Breathing bags in all other circuits contain natural latex rubber. No. yankauer.) (Cat. No. Port 15808 E 10’ w/5µ 15808 • 3 1 15808 24”–82” 3LF 1 15810 30600133 24”–82” 3LF 1 15808 351500 24”–82” 351503 40”–108” 3 351513 40”–108” 3 30600105 • • • • CE 10’ M/M CE 10’ M/M 1 3040005545 40”–108” 3 (textured) 1 19402 30600018 40”–108” 3LF 1 14412 30600104 40”–108” 3LF w/yankauer 30600165 40”–108” 3LF 1 30600324 40”–108” 30600360 40”–108” 3 1 15810 • B 10’ M/F 15808 13312 15808 14412 • 30 30 – 20 P 30 GS 20 P 20 P 20 GS 20 GS 20 GS 20 P 30 P 20 20 20 – 20 B 10’ M/M G/S 20 Connections Elbow Masks F = Female GS = Gas Sampling 15808 = Medium Adult Valved Clear Comfort M = Male P = Plain 15810 = Large Adult Valved Clear Comfort R = Right – = None 1281 42 – P – NOTE: Circuits with no breathing bag or LF breathing bag are LATEX FREE.) Port on Wye Sampling Line • 40” 1281 Elbow Quantity Case GS 20 GS 20 GS 20 GS 20 GS 20 GS 20 26”–72” 3 1 3020001711 20”–72” 3 2 3040004663 20”–72” 3 3040004746 20”–72” 3 3040005090 20”–72” 3 13312 B 10’ M/M – 30 3040005506 20”–72” 3 19212 B 10’ M/M P 30 18832 18402 1L 30600014* 20”–72” 3LF 30600196 20”–72” 3 3040005371 24”–82” B 10’ M/M Temp. 5/pack ECG. = Medium Adult Valved Sure Seal 30 GS/Tip *Includes X-large blood pressure cuff.Adult Fixed Wye Expandable Circuits Cat. 10’ suction tubing L = Left 20 GS B 10’ M/M 2 2 GS . that may possibly result in an allergic reaction. Hose Length Bag (Liter) 311403 26”–72” 3 351400 26”–72” 351403 26”–72” 3 351413 26”–72” 3 1 351423 26”–72” 3 2 357413 26”–72” 3 1 371413 Filter Extension Detachable HCH Mask Hose Limb (Cat. No. low compressible volume. *Includes temperature port on wye NOTE: Circuits with no breathing bag or LF breathing bag are LATEX FREE.) (Cat. Case • 2 B 10’ M/M • GS/Tip 30 GS 30 – 30 – 20 GS 30 GS 30 GS 30 GS 30 Hudson RCI offers Pediatric Circle Systems that are designed to be lightweight with low resistance and dead space. that may possibly result in an allergic reaction. Anesthesia Circuits & Accessories 43 .) Line Port on Wye Elbow 1 P 30 GS 20 1 GS 20 2 GS 20 1 GS 20 1 GS 20 3020004860 30” 1 3030002716 30” 1 30700010 30” 1 16412-BHS 39” 2 3020001214 39” 1 2 3020003907 39” 1TX 1 30700104 39” 1LF 30700112 39” 2LF 30700030* 48” 1 1 w/2 detach limbs 313901 60” 1 40” 353900 60” 353901 60” 1 353911 60” 1 353912 60” 2 393911 60” 1 1R 3020002055 60” 1LF 3020005172 60” 1LF 3020005535 60” 3040005505 RSC 11012 RSC 30 GS 30 GS 30 B 10’ w/. No. Hose Bag Length (Liter) 1 Filter 174112 30” 353800 30” 353801 30” 353802 30” 353811 30” 1 353812 30” 2 2 Extension HCH Mask Gas Sampling Gas Sampling Hose (Cat. Breathing bags in all other circuits contain natural latex rubber. No.8µ GS 30 E 10’ M/F D 10’ M/M P 30 20 GS 20 GS 20 1 GS 20 1 GS 20 GS 20 GS 30 • B 10’ M/F 11012 B 10’ M/M 11012 B 10’ M/M 3020002506 17”–72” 1 3020004123 17”–72” 1 2 1 1 w/2 detach limbs 17”–72” • GS 1 17”–72” 30 30 1 30700110 30 P – 60” 30700035 GS GS 17”–72” 353471 Qty.8µ GS 30 B 10’ w/.Pediatric Circle Systems Cat. No. and 15mm x 22mm machine cuffs. Breathing bags in all other circuits contain natural latex rubber. 44 Hose Length 1400150 12” 1L 1400250 12” 2L 1400550 12” .5L 354007 12” 1L 7145 12” 3L 354103 40” 3L 20 Cat. NOTE: Circuits with no breathing bag or LF breathing bag are LATEX FREE. clear outer tubing and blue inner tubing • Eliminates need for directional valves and soda lime absorbers • Individually packaged 10 to a case Cat No. No. that may possibly result in an allergic reaction. 20 20 20 20 • Includes fresh gas tubing and Norman gas elbow • 50 to a case .Bain Circuits Bain Breathing System • Coaxial design for better humidification and convenience • Better control of PaCO2 levels • Lightweight. 29005 20 Fresh Gas Start Up Kit 20 20 20 • • • Hudson RCI offers a Fresh Gas Elbow with barbed connection that swivels 360° to prevent kinking of fresh gas tubing. • Precise control of PaCO2 levels can be achieved by regulation of fresh gas flow Gas Sampling Elbow / Cap • • • • • Single Limb Non-Rebreathing Systems Modified Jackson-Rees. Mapleson D • All circuits include Norman gas elbow and 72-inch fresh gas tubing Bag (Liter) Bleed Valve Quantity Case 1456250 2L . Hose Length Bag (Liter) BD2491 60” BD2494 60” 1 BD2498 60” 3 BD7145 33” 1 BD02492 72” Hudson RCI offers the original “tube-withina-tube” partial nonrebreathing circuit.5L • • • • • 20 1462550 Cat No.5L 354001 12” 1L 354006 12” . CPRAM circuit and elbow • Easy.CPRAM Circuits Cat.001” from patient end • Reduced resistance to exhalation provided by conical shape of the fresh gas outlet • LF denotes latex-free breathing bag • Respiratory Assist Device for patient transport • Non-disposable swivel valve that can be opened or closed to adjust pressure desired for ventilation • Used with breathing bag. that may possibly result in an allergic reaction. Anesthesia Circuits & Accessories 45 . No. one-hand operation Gas Sampling Elbow Case 13200 40” P 20 13200-951 40” GS 20 13201 40” 1 P 20 13201-951 40” 1 GS 20 13201-952 40” 1 GS/Tip 20 13201-BQM 40” 1LF GS 20 13202-665 40” 2 13202-951 40” 2 13300-944 72” 13300-951 72” CSL RSC RSC P 20 GS 20 P 20 GS 20 13301-934 72” 1LF P 20 13301-951 72” 1 GS 20 13302-951 72” 2 GS 20 13303-951 72” 3 GS 20 13400 60” P 20 13400-951 60” GS 20 13401-951 60” 1 GS 20 13402-951 60” 2 GS 20 13403-951 60” 3 GS 20 13403-540 120” 3 P 10 NOTE: Circuits with no breathing bag or LF breathing bag are LATEX FREE. Hose Length Bag (Liter) CPRAM® Breathing System Cat. No. 13900 Controlled Partial Rebreathing Anesthesia Method CPRAM RAD Valve • Coaxial combination of corrugated inner (green) and outer (clear) tubing reduces kinking • Non-breakable fresh gas inlet is tapered and barbed to grip varying diameter tubing • Radial delivery of fresh gas with vortex dynamics improves humidification and CO2 removal • Reduced dead space as fresh gas outlet positioned only . Breathing bags in all other circuits contain natural latex rubber. No. Quantity Case Cat. No. 2L and 3L blue latex or green. No. Description Size Latex Qty. No.D.5L.Ventilator Hoses Ventilator Hoses • Available in 40 inch or 60 inch hose length with choice of cuffs • Additional 22mm adaptor available • Use adaptor Cat. • All bags are pleated and include 22mm female bushing • Available in 0.5L Latex-Free • • • • Ventilator Test Lungs 46 Cat No. 184000 20 Scavenger Tubing 20 • 19mm I. Size Latex 5421 1L 5422 2L • • • • 5423 3L 5425 . 1L. Case 29200 Test Lung 1L 292015 Heavy Wall 1L • • 10 5 Hudson RCI offers a full line of premium quality Disposable Anesthesia Breathing Bags which meet or exceed ISO and ASTM standards. 1409 or Cat. Hose Length Extension Hose Bag (Liter) Tubing Cuffs 360400 40” F/F 360410 40” F 1 180391 40” 6” F/M 1 HEPA 180392 40” 6” F/M 1 360600 60” Filter Additional 22mm Adaptor Disposable Ventilator Hoses address contagion concerns with cleaning of standard equipment reusable hoses. No. 1422 to build extra long versions Cat. cuffs • 100 foot roll in a convenient dispenser box • • 30 30 F/F 20 Anesthesia System Accessories Anesthesia Breathing Bags Breathing bags which are identical to those included in our standard anesthesia circuits. . latex-free neoprene • 20 bags to a case Breathing Bag Configurations Cat.5L 5431 1L 5432 2L 5433 3L 5435 . 125064 Nafion Dryer Line removes water vapor from sampled gases • 6” Nafion line with female/male connectors • 50 to a case Anesthesia Circuits & Accessories 47 . .060 Male/Male Female/Male PVC • • • • • • • • • • • 5.050 126463 96” C/E . 1230 • Small SARA disc filter designed for placement on machine end of gas sampling lines to protect monitor from moisture • 5.040 126713 120” E.050 1233 120” B. No. . No. Length Internal Diameter 1232 120” B.Gas Sampling Lines and Filters Sampling Lines • PVC sampling lines for measurement of end-tidal CO2 • Coextruded PVC. .050 1238 120” B.050 126263 96” B. No.8 Micron • • • • CoExtruded • • • Hydrophobic Disc Filter Cat. . .040 126664 96” D. .0 micron.0 Micron • • • • • • • • • • • • .047 126613 120” D. polyethylene sampling lines for precision measurement of anesthetic gases • All gas sampling lines include a male luer connector on one end for connection to the patient circuit gas sampling port • Choice of male or female luer for machine fitting • 50 to a case Cat.047 1236 120” B.050 1234 120” C/E . green • Standard male luer connector on one side and female luer connector on the other • 50 to a case Nafion® Tubing Cat.050 1237 120” B. . .050 1239 120” B.047 1235 120” C/E . . . Size Connector Size (mm) Inflation Port Ring Color 1271 Neonate 15 White 1272 Infant 15 Pink 1273 Pediatric 22 Yellow 1274 Small Adult 22 Green 1275 Medium Adult 22 Red 1276 Large Adult 22 Blue 1277 Neonate 15 1278 Infant 15 1279 Pediatric 22 1280 Small Adult 22 1281 Medium Adult 22 1282 Large Adult 22 • • • • • • White Pink Yellow Green Red Blue Mask Harnesses Flexible mask harnesses are designed for maximum patient comfort. • Color-coded retaining rings are removable for hand-held procedures • Available with optional inflation port for customized fit and comfort • Individually packaged 20 to a case . low pressure seal. No. No. No. No. 15911 Child . 15800 Size Neonate Connector Size (mm) 15 Ring Color 15802 15804 Infant Child 15 22 White 15806 15808 Small Adult Medium Adult 22 22 Green Yellow 15810 Large Adult 22 Red SURE SEAL® Masks Cat.Reusable • Individually packaged 10 per case 48 SURE SEAL face masks incorporate specially designed nose area and comfortable. Cat. 15910 Adult . low pressure seal. No. These products contain natural latex rubber Cat. 15920 Universal Size • Single patient use • Individually packaged 50 per case Cat. • All sizes include an inflation port providing a customized fit and increased comfort • Individually packaged 30 to a case.Air Cushion Masks CLEAR COMFORT ® Masks • 22mm color-coded retaining rings are removable for hand-held procedures • Available in six sizes to accommodate a full range of patients CLEAR COMFORT premium face masks incorporate a flexible dome and a gas-tight.Reusable • Individually packaged 10 per case Cat. gas-tight. No. molded and gently cupped to minimize trauma during intubation CF Murphy Eye CF Magill Type Cat. Size I. No.5mm 5-10108 4. 5-10310 5. No.0mm 5-10217 8.0mm 5-10215 7.0mm 5-10314 7.0mm 5-10113 6.0mm 5-10216 8.0mm 5-10312 6. Cat.5mm 5-10119 9. No.5mm 5-10115 7. allows the tubes to soften at body temperature • Smooth tube tip. large diameter cuff provides positive tracheal wall seal and reduces area of tracheal wall contact • Low pressure cuff minimizes capillary restriction • Tapered cuff eases insertion while minimizing risk of herniation • Oral or nasal use • Available with Murphy Eye only • Packaged sterile 10 to a case HVT Murphy Eye Cat.0mm 5-10118 9.5mm 5-10120 10.0mm 5-10109 4.D. 5-10106 3. Size I.0mm Size I. No.0mm 5-10210 5.D.0mm 5-10218 9.5mm 5-10208 4.D.0mm 5-10320 10.5mm Cat.0mm SHERIDAN/CF® Tracheal Tubes Close Fitting. low pressure cuff for short-term surgical intubation • Close fitting.5mm 5-10219 9.5mm 5-10316 8.0mm 5-10213 6.D. including: • High level of tactile feedback from pilot balloon • Thermosensitive PVC.0mm 5-10111 5.0mm 5-10116 8.5mm 5-10311 5. Size I. Size I.0mm 49 . Cat.5mm 5-10313 6.D.5mm 5-10214 7. 5-10206 3.0mm 5-10220 10.0mm 5-10114 7.5mm 5-10318 9.D. 5-10112 6.0mm 5-10107 3.5mm 5-10110 5. No.0mm 5-10315 7. Size I. opaque cuff eases intubation and increases visualization • Oral or nasal use • Available in Murphy or Magill style • Packaged sterile 10 to a case Airway Management Sheridan Endotracheal Tubes offer the features needed by today’s healthcare professionals.Endotracheal Tubes SHERIDAN/HVT ® Tracheal Tubes High Volume Tapered.0mm 5-10317 8.5mm 5-10212 6.5mm 5-10117 8. Low Pressure Cuff • High volume. Cat. Low Pressure Cuff • Close fitting. Size I.0mm 30mm 4.5mm 5-10412 6.D.0mm 5-10506 3.0mm 5-30412 6. Size I.0mm 5-10405 2. Size I. 5-10404 2.5mm 5-10414 7.5mm 32mm 5. gently cupped tip minimizes trauma during intubation • Tube softens at body temperature to conform to airway anatomy • Oral or nasal use • Packaged sterile 10 to a case Murphy Eye Magill Type Cat.5mm 41mm 7.0mm 39mm 6.5mm 5-10410 5.0mm 5-30406 3. molded.0mm 5-30509 4. 5-30409 4. Tube Size I.5mm 5-30507 3.5mm 5-30405 2. No. Size I.5mm 5-30511 5. No.Endotracheal Tubes SHERIDAN UNCUFFED™ Tracheal Tubes • Special depth lines at distal tip 1cm apart reference depth of intubation below the vocal cords • Smooth.D.0mm 5-30512 6. molded.0mm 5-10413 6. Cat. No.0mm 5-10504 2.5mm Cat. No.5mm 5-10408 4.0mm 5-30508 4.D. Size I. Cat.D.0mm 5-30408 4.5mm 5-10406 3.5mm 5-30407 3. gently cupped tip to minimize trauma during intubation • Oral or nasal use • Packaged sterile 10 to a case Distal Tip to End of Mark Murphy Eye Magill Type PED-SOFT Uncuffed Endotracheal Tubes include a distinct distal tip mark which serves as an aid during intubation.0mm 5-10512 6.5mm 5-30513 6.0mm 5-30414 7.0mm 5-30410 5.5mm 28mm 4.0mm SHERIDAN PED-SOFT™ Uncuffed Tracheal Tubes • Soft PVC formulation makes tube compliant to a child’s anatomy • Additional depth marks toward distal tip assist in placement during nasal intubation • Smooth.0mm 5-10514 7.0mm 26mm 3.0mm 5-30404 2.5mm 5-30505 2.0mm 5-10409 4.0mm 5-10508 4.0mm 5-30506 3.5mm 50 .0mm 5-30514 7.0mm 5-30504 2.5mm 24mm 3.0mm 5-10411 5.5mm 5-10505 2. No.D.5mm 5-10509 4.0mm 5-30510 5.0mm 5-10510 5.0mm 34mm 5. 20mm 2.0mm 22mm 2. Cat.5mm 5-10513 6.5mm 5-10507 3. The length from the distal tip to end of the mark varies with tube size.5mm 5-30411 5.0mm 5-10407 3.5mm 5-10511 5.5mm 5-30413 6.D.5mm 36mm 6. 5mm 5-22211 5.0mm 5-22218 9. Cat.0mm 5-22108 4.0mm 5-22315 7.5mm 5-22107 3.5mm 5-22314 7.0mm Airway Management Nasal Preformed Tracheal Tubes Cuffed Nasal Uncuffed Nasal Cat.0mm 5-22216 8. Size I.0mm 5-22111 5. 5-22008 4.0mm 5-22113 6. Size I.D.5mm 5-22014 7.5mm 5-22114 7.0mm 5-22007 3. Oral Preformed Tracheal Tubes Uncuffed Oral Cuffed Oral Cat.0mm 5-22214 7.5mm 5-22109 4.0mm 51 .0mm 5-22106 3.5mm 5-22010 5.D.5mm Cat. No. large diameter cuff for positive tracheal wall seal • Low pressure cuff minimizes capillary restriction • Bold marks at the center of bend with distance to distal tip indicated • Cuffed tubes available with Murphy Eye only • Uncuffed tracheal tubes have two Murphy Eyes for enhanced patient safety • Packaged sterile 10 to a case Sheridan Preformed tubes for oral and maxillofacial surgery allow the anesthesia circuit to be conveniently positioned out of the surgical field. Size I. No. Size I. 5-22312 6.5mm 5-22012 6. No. No.D.D.5mm 5-22316 8.5mm 5-22217 8.0mm 5-22212 6.0mm 5-22313 6. 5-22006 3.5mm 5-22213 6. Size I.5mm 5-22215 7.0mm 5-22210 5.5mm 5-22112 6. No.D. Cat.0mm 5-22013 6.0mm 5-22009 4.0mm 5-22011 5.0mm 5-22110 5.5mm 5-22209 4.0mm 5-22208 4.Endotracheal Tubes SHERIDAN PREFORMED™ Tracheal Tubes • High volume. No.0mm 5-12515 7. oral/nasal length features special radiopague distal tip for x-ray visibility.5mm 5-12618 9. Cat.0mm 5-19015 7. .5mm 5-12409 4. 5-12610 5.5mm 5-12511 5.D.5mm 5-19014 7.0mm 5-12512 6.D.0mm 5-12614 7. 5-19010 5.0mm 5-12612 6.5mm 5-12516 8. 5-12906 3.5mm 5-12908 4. Size I.D. Size I.0mm 5-19013 6. Size I. Cat.D.0mm 5-12410 5.0mm 5-19012 6. blue cuff • Packaged sterile 5 to a case NAZ-AL Tracheal Tubes are constructed of a special PVC blend with enhanced softness for nasal intubation and feature a soft atraumatic tip.5mm 5-19016 8.D.0mm Cuffed Oral/Nasal 52 Cat. Cuffed Oral Cat. No.0mm 5-12406 3.D.5mm 5-12518 9. No. No. Size I.0mm 5-12909 4.0mm 5-12615 7.0mm 5-12907 3. low pressure. Size I.0mm 5-12408 4. Size I.5mm 5-12616 8.5mm 5-12611 5.5mm 5-12910 5. oral precut length features reinforcing sleeve which minimizes risk of patient biting and occluding the tracheal tube. Spiral-Flex cuffed.0mm SPIRAL-FLEX® Reinforced Tubes • Oral length tube includes preinserted SHER-I-SLIP stylet • Spiral stainless steel reinforcing wire within tube wall reduces risk of kinking • 15mm connector permanently bonded within tube • High volume tapered.5mm 5-12513 6. No. No.D. 5-12510 5.0mm Uncuffed Oral/Nasal Murphy Uncuffed Oral/Nasal Magill Type Cat.0mm 5-12514 7.0mm 5-12617 8. low pressure cuff • Distinctive translucent white color • Inflation take-off point positioned close to connector end for patient comfort • Wall thickness minimizes risk of kinking • Available with Murphy Eye only • Packaged sterile 10 to a case Cat.0mm Spiral-Flex cuffed.5mm 5-12407 3. No.0mm 5-12517 8. Cat.Endotracheal Tubes NAZ-AL™ Tracheal Tubes • High volume tapered.5mm 5-12613 6. Size I. angled tip for ease of insertion • Packaged sterile 5 to a case Cat. Cat. Size I. cuffed. for patient ventilation • May also be useful for patients with narrow airways preventing use of a larger tube • Same tube length and cuff diameter as an 8.0mm 5-22405 2. 5-22510 5.D.5mm 5-22518 9.0mm 5-11716 8.0mm 5-22411 5.0mm 5-22407 3. secure handles.0mm SHERIDAN LTS™ Tracheal Tubes For Microlaryngeal Tracheal Surgery • Small O. 53 .D. No.D. Size I. No. tapered endotracheal tubes with stylets • Packaged sterile 10 to a case Cuffed HVT Airway Management EZ-Endo Tubes are pre-loaded with SOFT-TIP intubating stylets which have large. Uncuffed Cat.D.5mm 5-22515 7. high volume.0mm 5-11110 5. No.D. No.5mm 5-22513 6.0mm 5-22516 8.0mm Note: Not designed for use in presence of laser energy.5mm 5-22408 4.0mm 5-22409 4.0mm EZ-ENDO™ Tracheal Tubes • Sheridan HVT.D. Size I.0mm 5-22514 7. tube allows greater access to surgical field yet provides sufficient I. low pressure.5mm 5-22406 3.Endotracheal Tubes LAR-A-JECT ® Reinforced Laryngectomy Tracheal Tubes • Special “J” shape for convenient placement through a tracheostomy stoma • Spiral stainless steel reinforcing wire within tube wall reduces risk of kinking • Anesthesia circuit connection is out of surgical field during operations on larynx and trachea • High volume.0mm 5-11112 6. 5-11108 4. Size I.0mm 5-22512 6.5mm 5-22511 5.5mm 5-22410 5. 5-11714 7. distinctive blue cuff • Smooth.0mm 5-11718 9.5mm 5-22517 8.0mm cuffed tube • High volume. yellow cuff is highly visible and provides a low pressure tracheal wall seal • Oral or nasal use • Available with Murphy Eye only • Packaged sterile 10 to a case Cat. D. 5-16028 28Fr 5-16035 35Fr 5-16037 37Fr 5-16039 39Fr 5-16041 41Fr SHER-I-BRONCH Accessory Pack Right-Sided SHER-I-BRONCH Endobronchial Tube • Contains large eye for ventilating right upper lobe bronchial orifice • Unique double cuff design increases the “margin of safety” when positioning the tube in the right mainstem bronchus • Packaged sterile one to a case Right-Sided Cat. Left-Sided Cat. No.D. No. No. Cat.Endotracheal Tubes SHER-I-BRONCH ® Endobronchial Tubes • • • • Color coded bronchial and tracheal airways Cuff attachment points and tube tip are radiopaque Full scale depth marks and tear-resistant cuff Blue x-ray line for ease of visualization during fiberoptic scope insertion • Each Sher-I-Bronch endobronchial tube includes an Accessory Pack. 54 • SHER-I-SWIV FOTM double swivel connectors for use with fiberoptic scope • “Y” connector . No. Size I. 41Fr Cat. 5-16128 28Fr 5-16135 35Fr Cat. packaged separately Left-Sided SHER-I-BRONCH Endobronchial Tube • Designed specifically for intubation of the left mainstem bronchus • Packaged sterile one to a case SHER-I-BRONCH is a double lumen endobronchial tube designed for selective one-lung ventilation. 5-16142. 39Fr. For Use with SHER-I-BRONCH 5-20708 8Fr 28Fr 5-20710 10Fr 35Fr 5-20712 12Fr 37Fr. 5-16142 5-16137 37Fr 5-16139 39Fr Each accessory pack includes: 5-16141 41Fr SHER-I-BRONCH Suction Catheters Special length suction catheters for use with Sheridan endobronchial tubes • Packaged sterile 20 to a case Size I. No. Size I.D. 0mm FLEX-C-PAP® System Cat. 5-15401 • Connector for use with Fiberoptics • Allows easy passage of fiberoptic scope while maintaining an air tight seal around scope • Packaged sterile 25 to a case LASER-TRACH® Tracheal Tube • Unique embossed copper foil diffuses laser energy minimizing unintended laser damage to tissue • Clinically proven red rubber material • Atraumatic outer covering minimizes damage to mucosal surfaces and vocal chords • C-clamp. 5-16000 • Modified Mapleson D System with Norman elbow allows for addition of oxygen at patient connector • 6” . Absorbent pledgets provide extra cuff protection. 55 .24” expandable tubing with wye for easy access to adjustable PEEP valve and 1L Latex-Free breathing bag • Valve on fixed wye connector allows clinician to dial in desired amount of CPAP • 7 feet oxygen tubing connects Norman elbow with universal connector • Single patient use • Individually packaged 10 to a case Laser-Trach tubes are indicated for use with CO2 and KTP lasers. maintains inflation of the saline filled cuff • Convenient female luer lock connector secures syringe to inflation line • Overall length is equivalent to standard 8.D.0mm tracheal tube • Available with Murphy Eye only • Packaged sterile 5 to a case Cat. 5-20608 4.0mm 5-20612 6.Endotracheal Tubes SHER-I-SWIV® Double Swivel Cat. No. No. 5-15301 • For use with tracheostomy and tracheal tubes • Reduces breathing circuit drag and torque on tracheal tube and allows easy suction catheter passage with secure closure • Strap connector for anti-disconnect security and special swivel joints reduce leakage potential • Packaged sterile 25 to a case Airway Management SHER-I-SWIV/FO™ Double Swivel Cat. The FLEX-C-PAP system may be used with SHER-I-BRONCH endobronchial tubes to perform one lung ventilation. No. No. when engaged. Size I.0mm 5-20610 5. NOTE: This product contains natural latex rubber. 5mm 5-21516 8. No.5mm 5-11405 2.D.0mm 5-21513 6.0mm 5-20515 7.0mm 5-11406 3.0mm 5-21515 7.D.5mm 5-12008 4. Cat.5mm 5-20516 8.5mm 5-12006 3. 5-11404 2. incorporate an additional lumen and injection port for rapid drug delivery below the cuff.0mm 5-20513 6.0mm 5-12007 3. ideal for use when laryngospasm is anticipated during intubation or extubation. 5-20512 6.5mm 5-11409 4. Cat. low pressure cuff • Oral or nasal use • Available with Murphy Eye only • Packaged sterile 10 to a case 56 Sheridan ETCO2 Tubes allow CO2 monitoring and can also be used for pressure monitoring or tracheal irrigation. Size I.5mm 5-21514 7.5mm 5-20514 7.D. No.D.5mm Sheridan STAT-MED Tubes designed for adolescent and adult patients. No.0mm 5-12005 2.0mm 5-11410 5.0mm 5-21517 8.5mm 5-12010 5. LITA Tracheal Tubes allow for spray application of topical anesthetic via specially designed lumen. Size I. 5-21512 6. .0mm SHERIDAN STAT-MED™ Cuffed Tubes • Medication injection port allows for rapid drug delivery directly to pulmonary system • May also be used for monitoring pressure or tracheal lavage • Oral or nasal use • Available with Murphy Eye only • Packaged sterile 10 to a case Cat.0mm 5-11408 4.0mm 5-12009 4.5mm 5-11407 3. Size I.Endotracheal Tubes SHERIDAN ETCO2™ Uncuffed Tubes with Monitoring Lumen • Allows CO2 monitoring at distal tip of tracheal tube providing improved capnogram • Reduces dead space by eliminating adaptor • Packaged sterile 10 to a case Uncuffed Oral Uncuffed Nasal Cat.0mm 5-20517 8. No. Size I.5mm LITA™ Cuffed Tracheal Tube For Laryngotracheal Instillation of Topical Anesthetic • Patient tolerance of endotracheal tube is increased after administration of topical anesthesia • Black reference bar indicates the position of uppermost opening • High volume tapered. 8.X. 5-24205 • Jet ventilation capability with the JETTX provides additional time to assess spontaneous breathing • Luer lock adapter on JETTX can be easily attached to conventional jet ventilation devices • Can be used for oxygen delivery • For use with tube size 6. highly visible depth marks also assist when replacing an endobronchial tube • For use with 35 Fr .10. No.6.4. without use of a laryngoscope • Hollow to allow for spontaneous breathing • Packaged sterile 10 to a case Sheridan E.T. No.5mm . For Tube Sizes 5-24000 2. • Depth marks provide a guide for placement of endotracheal tube.5 .0mm ID 81cm 57 .X. without the use of a laryngoscope • Unique. 5-24105 • 100cc length provides easy exchange of endobronchial tube with a standard tube.™ Exchanger Tracheal Tube Exchanger • Allows quick and efficient endotracheal tube replacement • Flexible for easy insertion • Frosted surface minimizes drag • Includes depth marks • Hollow to allow for spontaneous breathing • Packaged sterile 10 to a case Cat.™ Exchanger Endobronchial Tube Exchanger Cat.0mm .0mm ID 81cm 5-24004 6.D.0mm ID Length 56cm 5-24002 4.10.5mm ID 81cm 5-24006 7.T.41 Fr SHER-I-BRONCH endobronchial tubes • Hollow to allow for spontaneous breathing • Packaged sterile 10 to a case Sheridan T.0mm .0mm I. No.5mm .Endotracheal Tubes Sheridan JETTX™ Exchanger Airway Management Jet Ventilation/Tracheal Tube Exchanger Cat. 0 .5 25cm 5-15103 10Fr 5. 5-15101 10Fr 5. O.10. • Individually packaged sterile 20 to a case Cat. 1065 endotracheal tube holder • Packaged 50 to a case (10 to a bag/5 bags to a case) • Tube may be attached to holder using either tape or safety pin • Supplied with cloth tie. safety pin and soft foam mouth cushion • Individually packaged 10 to a case 58 .D.D.10. 1066 • Keeps endotracheal tube in place without applying tape to patient’s face. No. No.Stylets SHER-I-SLIP ® Intubating Stylet SHER-I-SLIP intubating stylets are designed to retain the desired curve during oral intubation.0 . No. • Special material reduces stylet-to-tube friction • Individually packaged sterile 25 to a case 10Fr 5Fr Cat. Size For Tube Sizes (mm) I.5 . Size For Tube Sizes (mm) I.5 33cm 5-15120 6Fr 2. • Replacement cushions for use with Cat.5 .0 .0 X-Long Length X-Long 10Fr SOFT-TIP Intubating Stylet SOFT-TIP intubating stylets feature a soft.D.10.5 27cm Length 31cm SOFT-TIP Endotracheal Tube Holder Mouth Cushion Cat. O. low friction sheath that extends beyond the tip.7.4. 1065 Cat. No. 5-15100 14Fr 8.0 .0 34cm 5-15102 5Fr 2.D.4.0 5-15110 10Fr 4. No. for securing the holder. No. Child 51005 Silicone Bag Assembly.) 51007 Oxygen Reservoir. and reservoir valve assembly Airway Management • • • • Durable masks feature silicone construction Larger masks include clear rigid shell Components completely autoclavable Sold individually 59 . 5345 Adult Bag • Includes mask. No. No. Size 5190 Small Infant 5191 Large Infant Infant Bag • Mask and reservoir bag not included 5192 Small Child 5193 Large Child Cat. No. Small Adult 50473 Mask Bladder. 5341 5336 Expiratory Flow Diverter 51000 Nonrebreathing Valve Assembly. 1669 adaptor positioned between mask and bag. Child / Infant 51002 Nonrebreathing Valve Assembly. No. convenient storage • Nonrebreathing valve offers low resistance to both inspiratory and expiratory gas flows • Cat. reservoir bag. 600mL 50470 Mask Shell. • Autoclavable (except reservoir bag) • Easy to assemble • Collapsable. Adult 51004 Silicone Bag Assembly. and reservoir valve assembly Child Resuscitators Cat. Child / Infant 51009 Pressure Relief Valve Assembly 51003 Silicone Bag Assembly.LIFESAVER Reusable Resuscitators Replacement Parts Cat. Adult 51015 Nonrebreathing Valve Housing. No. Large Adult 50474 Mask Grommet Child Bag • Mask and reservoir bag not included 50475 Nose Retainer 50476 Side Retainer (2/pkg. may be used for pressure or CO2 monitoring • Sold individually Replacement Masks Cat. Infant 51018 O-Ring (5/pkg. Flow Diverter (1 set) Child Bag • Includes mask. and reservoir valve assembly Infant Resuscitators Cat. Description Adult Resuscitator Cat. No. reservoir bag. for compact. 5342 The Lifesaver Reusable Resuscitator is designed to meet ISO and ASTM standards. Small Adult 50471 Mask Shell. 5340 Adult Bag • Mask and reservoir bag not included Cat. No. 5347 5194 Small Adult 5195 Large Adult Infant Bag • Includes mask.) 51016 Duckbill Valve (5/pkg.) Cat. Large Adult 50472 Mask Bladder.) 51012 Intake Valve Housing 51019 Intake Valve (5/pkg. reservoir bag. Adult 51011 Downstream Housing Assembly 51017 Exhalation Valve (5/pkg. No.) 51014 Nonrebreathing Valve Housing. 5346 51013 Valve Kit (1 set) 51024 Seal Kit. 2500mL 51008 Oxygen Reservoir.) 51006 Reservoir Valve Assembly 51020 Reservoir Valve Housing 51021 Reservoir Valve Seat 51022 Reservoir Valve Cover 51023 Reservoir Valve (2/pkg. No. • Swivel flow diverter allows connection of PEEP valve • Includes adult face mask. tamper evident bags. Size Pediatric Mask (#1273) 5361 Infant • 5362 Infant 5364 Infant 5366 Pediatric 5367 Pediatric 5369 Pediatric Neonate Mask (#1271) PEEP Valve • • • • • • Adult Foldable Resuscitation Bag Cat. No.Disposable Manual Resuscitators Adult Resuscitation Bags Available with a variety of options including a capped pressure monitoring port / 60cm pop-off valve style. features and performance. No. • All configurations include swivel flow diverter for connection of PEEP valve • Available with optional PEEP valve Cat. Cat. No. 1276 • Individually packaged in drawstring. 5387 Foldable bag incorporates the same great features as the standard LIFESAVER adult bag and collapses for compact storage. Shown in collapsed position. Mask (#1276) 5371 • • 5372 5374 5377 Valved Mask (#1282) PEEP Valve • • • Pop-Off Valve • • 5380 Pediatric and Infant Resuscitation Bags All pediatric/child and infant/neonatal bags include a capped pressure monitoring port and 40cm pressure relief pop-off valve. 6 to a case 60 LIFESAVER® Disposable Manual Resuscitators combine quality. • All configurations include swivel flow diverter for optional connection of PEEP valve • Available with optional PEEP valve Cat. • Designed to meet ISO and ASTM standards • Unique right-angle O2 tubing connector swivels 360 degrees • 100% latex-free • Includes STAR-LUMEN tubing and universal oxygen connector • Individually packaged 6 to a case . STAR LUMEN oxygen tubing and 7-ft. 5402.PEEP Valves Disposable PEEP Valve (30mm) Cat. (Cat.5L 5403 . No. 5404 Cat. 5403 Note: Cat.5L 5401 .D. pressure tubing • Cat. connector • For use with respiratory products that incorporate a 22mm connection • Packaged 10 to a case 5383 Hyperinflation Bags Hyperinflation Bags • High quality. labor and delivery or during patient transport. No.5L 5404 1L 2700-205 . 5401. 5400. No. No. 5383 5385 • Adjustable 0 to 20cmH2O • ISO standard 22mm O.5L 5402 . No.D. durable bag allows clinicians to feel the patient’s lung compliance • Adjustable valve for fingertip control of system pressure • Available with 7-ft. No. 15800) and infant mask (Cat. 5385 • Adjustable 5 to 20cmH2O • ISO standard 30mm I. and 5404 contain natural latex rubber. No.5L Latex Free • • Oxygen Tubing Pressure Tubing • • • • • • • • • • 61 . connector • Attaches to any resuscitation bag flow diverter with 30mm connection • Packaged 10 to a case Airway Management Disposable PEEP Valve (22mm) Cat. Bag Size 5400 . 15802) • Individually packaged 20 to a case 5400 The Hyperinflation Bag System is designed to provide controlled or assisted ventilation to neonatal and pediatric patients in NICU. 2700-205 includes both neonate mask. • Ideal design allows for removal without disconnecting or displacing positioned endotracheal tube • Flat lingual surface widens gradually at distal end • Flexible curved guides between vertical side walls at the buccal end permit removal of the airway from around a tracheal tube • Tubular proximal half functions as a bite block • Distal half is open posteriorly to provide fiberscope maneuverability • Fits adults 80mm-90mm • Individually packaged 5 to a case 62 . 1173 • Contains all eight disposable CATH-GUIDE airways in a sturdy compact case • Includes flanged connectors to allow the airways to be assembled into three LIFESAVER tube sizes. No. • Sold individually Ovassapian Airway Cat. BD6075 The Ovassapian fiberoptic intubating airway is intended primarily for use in intubations utilizing a fiberoptic endoscope. No.Oral Airways Emergency LIFESAVER® Kit Cat. No. No. Size 1165 12 120mm 1166 11 110mm 1167 10 100mm 1164 9 90mm 1168 8 80mm 1169 7 70mm 1170 6 60mm 1171 5. nontoxic polyethylene with color-coded bite block • Guedel-style enclosed center channel • Individually packaged 48 to a case Cat. Size 1148 10 100mm 1149 9 90mm 1150 8 80mm 1151 6 60mm 1152 4 40mm 63 . No.5 55mm Airway Management Color-Coded Airways • Semirigid. No. No. No.Oral Airways CATH-GUIDE® Airways • Flexible vinyl with a rigid bite block • Guedel-style with three internal channels • Individually packaged 48 to a case Cat. Size 1161 11 110mm Color 1160 10 100mm Red 1159 9 90mm Yellow 1158 8 80mm Green 1157 7 70mm White 1156 6 60mm Black 1155 5 50mm Blue 1154 4 40mm Pink Orange Dual-Channel Airways • Semirigid. nontoxic polyethylene • Two-channel. Berman design • Individually packaged 48 to a case Cat. 1178 • Anatomically contoured to position the patient for effective application of CPR • Recessed handles help position board and aide lifting • Measures 231/4”x 171/4” • Weighs 41/2 lbs. • Prevents damage to laryngeal mask airways (LMA). 29003 • Anatomically shaped dental guard is designed to protect patient’s teeth during procedures which require oral manipulation. 1140 Disposable. No. pliable resin • Convenient handle provides easy access for repositioning • Individually packaged 20 to a case Cat. semirigid plastic bite block / tongue depressor • Maintains a patent airway while helping to prevent self-inflicted oral injury • Packaged 50 to a case CPR Board Cat.Bite Blocks BiteGard ® Cat. • Sold individually 64 . • Manufactured of soft. No. compressible molar bite block provides a cost-effective solution for patients who clench their teeth. No. 1174 • Disposable. No. bronchoscopes and other valuable medical equipment • Individually packaged 50 to a case Dental Guard Bite Stick Cat. No. 1184 Cat.D.D. No. 1181 Isolation Valve • 22mm I.Rescue Devices PocketPak Resuscitator Cat. connections Filtered Isolation Valve • Same as 1180 but with pathogen filter Cat. The collapsible mask is easy to use and convenient to carry. No. 1181 valve • Child mask • Mouthpiece Includes: • Cat.D. No. / 15mm I. No. No. clear dome to provide secure seal Capped port for delivery of supplemental oxygen Low-resistance valve and particle filter Foldable extension tube Packaged in a sturdy “clam shell” case. The disposable valve directs rescuer’s breath to the patient while diverting exhalation away from the rescuer. 1181 valve • Adult mask • Mouthpiece • 6-in. No. Airway Management PocketPak features: • • • • • Mask with pliable. 1182 Cat. No. 1186 Adult Kit Adult Filtered Kit Child Filtered Kit Adult Filtered Kit Includes: • Cat. flexible tube 65 . No. 4 masks to a convenient storage box Isolation Valves and Kits 1186 The Hudson RCI isolation valves and kits prevent mouth-to-mouth contact during emergency resuscitation. 1180 valve • Adult mask • Mouthpiece Includes: • Cat. 1187 The PocketPak emergency mask kit provides effective protection for mouth-to-mouth resuscitation and fits standard manual resuscitators. No. No. 1180 Cat. 1185 Cat. 1185 1182 /1184 • Low-resistance duckbill valve minimizes rescuer’s fatigue • Patient connection swivels for easy positioning • Filtered version further decreases risk of crosscontamination • Individually packed 10 to a case Cat. x 22 O. 1181 valve • Adult mask • Mouthpiece Includes: • Cat. D. tubing.D. No. 18903 Reusable Patient Elbow Cat. No./22mm O./ 22mm O.D.D. 1624 Gas Sampling Elbow Cat.D.Elbows Cat.D. 1632 Norman Mask Elbow • Standard 22mm I. No.D. patient connection • 5 per case Wyes Cat.D.D. x 15mm I. No. connections • Accepts most temperature probes • 50 per case • 15mm O. No./ 22mm O. 1641 Elbow Adaptor Cat. 1660 Universal Wye Connector • 22mm O. tees./22mm O. tubing connections • 15mm I. patient connection • No ports • 50 per case • Temperature Monitoring Port • 22mm O. No.D.D.D. No. tubing connections • 15mm I. No. • 50 per case • Standard 22mm I. wyes. x 22mm O. 1673 Ported Elbow Adaptor Cat. • 50 per case • 15mm O. tubing connections • 15mm I.D.D. x 15mm I. No. • Female luer lock connection swivels 360° • 50 per case • 15mm O. 1675 Adult Near Parallel Wye Cat. 1078 Ventilator Adaptor • 15mm O. and much more in a wide range of sizes and designs. 1674 Adult Near Parallel Wye Cat. No.D.D.D. patient connection • Airway pressure and temperature monitoring ports • 50 per case Cat.D. 1660 but without temperature and pressure monitoring ports • 50 per case • 22mm O.D. x 15mm I. No.D. 1623 Patient Elbow Adaptor Cat. No. x 22mm O. tubing connections • 15mm/22mm O.D./22mm O. patient connection • 50 per case • 22mm O. • 50 per case Hudson RCI offers an extensive line of Adaptors and Connectors including elbows. • Elbow accepts 5-7mm I./ 22mm O. x 15mm I.D. No. swivels 360° • 50 per case Cat. 18902 Reusable Wye • Same as Cat. Cat. No. to address your respiratory and anesthesia needs. 1660 but without pressure monitoring port • 50 per case 66 .D.D. 1662 Wye Connector Cat./ 22mm O.D.D. No./22mm O.D. 1661 Wye Connector • Same as Cat. • Polycarbonate • 5 per case • Right-angle adaptor with a capped suction port • 15mm I.D.D.D. No. x 5-7mm tapered nipple • Can be used with Cat. connections • Port accepts temperature probes and thermometers • 50 per case • Standard 22mm O.D.S. x 22mm I.D. 1669 Monitoring Adaptor • 22mm O./ 22mm O. 1422 Multi Adaptor Cat.D. • 50 per case • Standard 22mm O. 1642 Pressure Line Adaptor Cat./22mm O. 1768 Step-Down Adaptor Cat.Adaptors and Connectors Cat. connections • 50 per case • Standard 15mm I. No.D. x 22mm I. No.D.D.D. No.D.D. x 15mm I. x 22mm O.D. 1423 Tubing Adaptor Cat. 1075 trach mask • 50 to a case • 15mm O.D. oxygen outlets • 50 per case Adaptors & Miscellaneous 67 . x 22mm I. 1421 Universal Cuff Adaptor Cat. x 22mm O. connections • 50 per case • 22mm I.D.D. 1420 Tubing Connector Cat. 1640 Tubing Adaptor • Standard 22mm I. • 25 per case • 15mm O.D. No.D. • 50 per case Cat. 380-74 Adult Probe Adaptor • Standard 22mm O. 2555 Nipple and Nut Adaptor • 15mm O.D.I.D. 1663 Soft Cuff Adaptor Cat.D. connections • Port accepts CONCHA temperature probes • 24 per case Cat. No.D. 1678 22mm ISO Cuff Adaptor Cat.D. No. No. • 25 per case • Hose adaptor for standard D. x 22mm I. connections • 50 per case • Approximately 21mm I. No.D.D. connections • Standard luer fitting • Can be used with Lifesaver resuscitation bags • 50 per case Cat.D. • Made of flexible material • 50 per case • Standard 22mm O. 1769 Step-Down Adaptor Cat. x 22mm I. connections • Elbow swivels 360° • 50 per case • Standard 22mm O. 1409 Large Tubing Connector Cat. No. No.S. x 22mm O. No. No. No.D.D.D. 1645 Thermometer Adaptor Cat. No. 9059 Adaptor with O2 Port Cat. x 19mm I. connections • Capped port • 250 per case • Couples oxygen supply tubing utilizing 5 to 7mm end connectors • 50 to a case • 22mm I.D. x 22mm I. No. No. No.D. 1 inch diameter • 10 per case 68 Same as 1180 but with pathogen filter See kits on page 65 . x 22mm I. No. x 22mm O. 1665 One-Way Valve Cat. 1644 One-Way Valve Cat. • 50 per case • Low flow resistance 22mm I. 1180 Isolation Valve • Low flow resistance 22mm O.D. No.D. connections • 10 per case • Clear housing with alcohol based red liquid column • Fahrenheit and Celsius scales from 50 to 120° and 10 to 50°.D. 1679 O2 Tubing Water Trap • 70cc capacity • 22mm O.D. 1637 Thermometer with Tee Adaptor Cat. No. No. No. 1664 One-Way Valve Cat. 1635 thermometer and Cat.D. • 50 per case Cat. No. 1181 Filtered Isolation Valve • • Water Traps Cat. No. 1635 thermometer and Cat. 1645 aerosol tee • 50 per case • Cat. 1647 Thermometer and Thermometer Adaptor Cat. / 15m I.Temperature Monitoring Cat. to 22mm I.D.D. No. connections 10 per case One-Way Valves • Assembled tee and two oneway valves allow gas to flow in only one direction • 50 per case Cat. 1648 aerosol tee connector • 50 per case • Combines Cat.D. No. No.D. No. No. connections • Valve offers low flow resistance • Capped monitoring port • 50 per case • 22mm I. 1658 Neonatal Water Trap Cat. No.D. x 22mm O. tubing connectors • Self-sealing lid to ensure circuit patency • 50 per case • 20-30cc capacity • Self-sealing lid to ensure circuit patency • 50 per case • Collects moisture that can accumulate in O2 tubing • Accepts all standard and crush-resistant oxygen supply tubing • Approximately 8 inches long. respectively • 50 per case • 22mm I. No. x 22mm O. No. to 22mm O. 390-45 AQUAPAK 37 In-Line Temperature Indicator (°C) • Combines Cat. 1635 Thermometer Cat.D. No. 1650 Water Trap Cat.D. 1666 Unidirectional Valved Tee • Standard 22mm O. pressure line • 100 per case Neonatal Adaptors 69 . x 22mm I.D.152 in. I.D. 1077 Aerosol Tee Connector Cat. • 50 per case • Anti-spill design minimizes aspiration of liquids • 22mm O.D. connections • Tee may be left in-line when nebulizer is removed • Port accepts most small volume nebulizers • 30 per case • 22mm O. No.D. pressure line • 100 per case • For connecting 1/8 in. x 15mm I. 1639 Nebulizer Tee Connector • 22mm O. No. No. and 7.D. I. connection • 100 per case • 10mm O. x 18mm I. No.D. x 18mm I.D.D. x 22mm O./ 22mm O.D. No. 1765 Neonatal Pressure Line Tee • For connecting 1/8 in. x 18mm I.D. • 50 per case • 22mm O.D. No. or away from patient for a reservoir effect Cat. connections • Port accepts most small volume nebulizers • 50 per case Adaptors & Miscellaneous MDI Adaptors Valved Tees The Hudson RCI Metered Dose Inhaler Adaptors are designed for placement at the patient wye. No. connections • Tee may be left in-line when nebulizer is removed • Port accepts most small volume nebulizers • 30 per case • 22mm O.D. No. 1743 Valved NebTee Cat. 1659 MDI Adaptor Cat.D.D. x 15mm I. • Adaptors fit most MDI cannisters and ventilator circuits • Arrow allows clinician to direct aerosolized medication toward patient.D.D.D. I. x 18mm I.D.D. 1763 Neonatal Probe Adaptor Cat. connections • Accepts most probes and thermometers • 50 per case • .5mm I.D. No. 1764 Neonatal Adaptor • Standard 10mm O. x 15mm I./ 22mm O.D. connections for in-line placement in 22mm tubing • 50 per case • 15mm O. orifices • 100 per case Cat. 1638 Nebulizer Tee Connector Cat. No.D.D. • For use when requiring a connection between 10mm I.D.D. connections for in-line placement in 15mm tubing • 50 per case Cat. tubing to 3/16 in.D. 1744 Valved NebTee Cat.D. O.D.092 in. x 22mm I. connection • .D. No. 1648 Aerosol Tee Connector Cat. x 22mm I.5mm O. tubing to 1/8 in. x 22mm O. 1402 Drive Line Adaptor Cat. 1766 Neonatal Pressure Line Tee Cat.D.D. x 7. x 22mm O. No.Tees Cat.D./ 22mm O. 1751 MDI Adaptor • 22mm O. No.D. x 22mm O.D. • Port accepts most small volume nebulizers • 50 per case • 22mm O. x 22mm O. No. neonatal tee and 12-inch 10mm corrugated tubing • 50 per case 70 Cat.D. No.5mm I.D. 1668 Trache Tee Oxygenator • 7 ft. No. No. • Designed to be used with CONCHA heated humidifier • 30 per case • 5/16-in barbed fitting • 15. 1565 Mouthpiece Cat. m/m oneway valve and m/f oneway valve Cat. connection • 50 per case • Includes drive line and hanger • 50 per case • Includes 18mm nebulizer adaptor. / 19mm O.D.D. adaptor • 50 per case • Prevents moisture from entering VENTILARM II monitor • 10 per case • Allows administration of oxygen to endotracheal or tracheostomy tubes • Includes oxygen nipple adaptor. 5612 In-Line Filter Cat. 1643 Exhalation Valve Cat. aerosol tee. 384-26 CONCHATHERM Oxygen Diluter Cat. No. aerosol tee.D. 384-10 CONCHATHERM Hose Adaptor Cat. 1792 Neonatal Adaptor Kit • Standard mouthpiece with 15mm/22mm O. No. CORR-A-FLEX tube • 50 per case Cat. / 19mm O. No. 15mm/ 22mm adaptor. allows delivery of specific oxygen concentrations • 30 per case • Adjustable 28% to 90% • When used with CONCHA humidifier.D. pressure line with luerlock connectors for connecting VENTILARM II monitor to ventilator circuit • Standard 22mm I. allows delivery of heated aerosol at specific oxygen concentrations • 30 per case Miscellaneous Ventilator monitoring adaptor circuit kit includes oxygen nipple adaptor. 388-28 CONCHATHERM Nebulizer Adaptor • Tapered fitting up to 7mm • 15.5mm I.CONCHATHERM® Adaptors Cat. and 6-in. No. 5614 Pressure Line Kit Cat. No.D. No. • Designed to be used with CONCHA heated humidifier • 30 per case • Adjustable 26% to 90% • When used with CONCHA humidifier. 6-inch CORRA-FLEX tube. No. 384-00 CONCHATHERM Tubing Adaptor Cat. 1667 Ventilator Monitoring Adaptor Circuit • Allows monitoring of ventilatory weaning parameters in intubated patients • 50 per case . No.B. 1742 • Disposable drainage bag with wye adaptor which accepts standard 22mm I.P. accurate system for computing tidal volume and minute volume • VENTI-COMP’s versatile adaptor allows unit to be connected to most expiratory ports • Accurately and reliably measures and / or evaluates the effectiveness of an I. corrugated tubing • 750cc bag capacity • Self-locking plastic chain secures bag to a stable object • Convenient drainage port • Individually packaged 50 to a case Cat. No. treatment • Designed to be simple and easy to use–requires no special technical knowledge or training • Precise and accurate readings from the easy-to-read chart printed directly on the VENTI-COMP unit • Single-patient use of VENTI-COMP eliminates possibility of cross-contamination • Individually packaged 50 to a case Adaptors & Miscellaneous Aerosol Drainage Systems Cat. 1550 • A disposable. No. 1740 • Disposable drainage bag with tee adaptor accepts standard 22mm I.D.Miscellaneous VENTI-COMP ® Cat.D.P. corrugated tubing • 750cc bag capacity • Self-locking plastic chain secures bag to a stable object • Convenient drainage port • Individually packaged 50 to a case 71 . Best flow window • Compact. low work-of-breathing design • Built-in handle • Packaged 12 to a case Pediatric Voldyne Cat. No.Better . ergonomic design • Advanced. 8884719025 The Voldyne 2500 volumetric exerciser features: • Volume measurement up to 2500mL accommodates smaller inspired volumes • Good . 8884719017 The pediatric Voldyne volumetric exerciser features: • Volume measurement up to 2500mL accommodates pediatric inspired volumes • Colorful. low work-of-breathing design • Built-in handle • Packaged 12 to a case Voldyne 2500 Cat. No. ergonomic design • Advanced. 8884719009 The Voldyne 5000 volumetric exerciser features: • Volume measurement up to 5000mL accommodates large inspired volumes • Good .Better . child-oriented labeling to facilitate patient evaluation and use • Pediatric sized mouthpiece • Compact.Incentive Spirometers Voldyne® 5000 Cat.Best flow window • Compact. No. ergonomic design • Advanced. low work-of-breathing design • Built-in handle • Packaged 12 to a case 72 . No. No. Low resistance design Sliding incentive indicator Compact design Packaged 12 to a case Triflo® II Inspiratory Exerciser Cat. 8884715700 The Air-Eze flow-oriented incentive spirometer features: • • • • • Wide flow rate range from 200-1200cc/sec. • Adjustable. 1750 The Hudson RCI LVE (Lung Volume Exerciser) encourages deep and prolonged inspiration. 3-ball incentive spirometer features: • • • • • Incentive Spirometers Spirometers Wide flow rate range from 600-1200cc/sec. Three color-coded balls/three chambers Minimum flow imprinted on each chamber Compact design and break-resistant plastic Packaged 12 to a case Lung Volume Exerciser Cat. clearly marked flow settings • Dual-chamber design creates constant resistance that lifts the ball when patient maintains inspiration equal to the selected inspiratory flow setting • Packaged 10 to a case 73 . It features: • Wide flow rate range from 200-1200cc/sec.Incentive Spirometers Air-Eze Breathing Exerciser Cat. No. 8884717301 The Triflo II flow-oriented. No. 1001-50 Cat. • Patient education video available upon request . No. No. No. inlet fitting • One-way valve allows exhaled air to exit mask • Available in four convenient sizes Cat.Spacers and Chambers SPACER and CHAMBER The POCKET CHAMBER utilizes a highly sensitive oneway valve to aid patients in timing their inhalation. compact and easy to use • Durable. 1293 Infant Mask Medium Mask • Case of 10 • Case of 10 Cat. if desired POCKET CHAMBER POCKET SPACER Cat. 1292 Cat. No. • Both devices feature a tethered cap to protect the mouthpiece • Both have standard 22mm mouthpiece for use with a variety of masks. • Constructed of pliable. No.D. No. Temecula. CA PANDA™ Mask The PANDA Mask is a clear. 1291 Cat. No. nonrebreathing mask designed for maximum patient comfort. 1002-10 • Case of 10 • Case of 10 Cat. • Case of 100 POCKET PEAK Peak Flow Meter meets or exceeds all NAEP and NHLBI standards. 1 Data on file Hudson RCI. 1805 POCKET PEAK Peak Flow Meter Disposable Carboard Mouthpiece • Case of 12 • 30 mm I. Over 40% smaller with performance equivalent to the most commonly used spacers and chambers 1. 1801 Cat. latex-free silicone with 22mm I. No. 1294 Small Mask Large Mask • Case of 10 • Case of 10 POCKET PEAK™ Peak Flow Meter • Universal 50-720 LPM range is convenient. No. sliding zone indicators encourage patient compliance • Colorful integrated markers allow patients to easily monitor changes in air flow • Ergonomically designed ABS plastic housing and tempered stainless steel vane are dishwasher-safe • Reusable plastic mouthpiece attaches to unit for secure storage 74 Cat.D. The POCKET SPACER features a grid of holes between the chamber body and patient mouthpiece. 1002-50 • Case of 50 • Case of 50 The Hudson RCI POCKET CHAMBER™ and POCKET SPACER™ are designed for portability and convenience to accommodate the varied life styles of asthma patients of all ages. 1001-10 Cat. 5804 sensor separately 5802 5801 Monitors. All units include state-of-the-art microprocessor controlled electronics. tank and liquid systems • Designed for simplicity and durability • Internally mounted sensor is protected from damage • Recessed LCD with clear cover for added drop resistance • Rugged ABS case • Operates 3. 5800 ”Intelligent” Oxygen Monitor Includes all the features of the intelligent instrument line plus: • Easy to set high/low oxygen alarm with audible and visual alarm indicators • Ninety second alarm mute and mute status indicator • Automatic high/low alarm test for verifying high/low alarm set points at the push of a button • Keypad lock with status indicators deters unintentional changing of alarm settings • Order Cat.500 hours on a single 9V battery • Sold individually Internal Oxygen Sensor • For use with Cat. No. No. No. 5811 • Ideal for oxygen identity checks with concentrators. No. No. 5803 sensor separately Cat. No. 5810 Cat. No. Ideal for spot checking tank and liquid oxygen systems and oxygen concentrators • Connects to oxygen with standard O2 tubing • Order Cat.000 . 5803 sensor separately 5800 The “Intelligent” Oxygen Monitor and Analyzer line features “low sensor” and “replace sensor” indicators. No. 5810 • Sold individually 75 . 5802 ”Intelligent” Oxygen Analyzer with Internal Sensor • Same design and features as Cat.Oxygen Monitor & Analyzers “Intelligent” Oxygen Monitor and Analyzers The “Intelligent” instrument line features patented technology that warns in advance of sensor expiration. No. No. 5801 but with internal oxygen sensor.4. 5801 ”Intelligent” Oxygen Analyzer with External Sensor • Ideal for spot-checking or continuous display of oxygen concentration in respiratory care or anesthesiology • Order Cat. Cat. All units include: • Automatic calibration to room air • Optional 100% oxygen calibration • On-screen calibration menu and instructions • Contrast adjustment • Battery strength indicator • Self-diagnostic check • Operate on two AA alkaline batteries Cat. Regulators & Cylinders Basic Oxygen Analyzer Cat. No. No. 5802 • Sold individually • For use with Cat. 5577. 5804 Cat. and 5550. No. 5528 and 5529 Cat. Nos. No. No. No.D. 5500 sensor • 22mm I. 5587 Cat. No. 5800 and 5801 • 18mm flow deflector fits a variety of tees • Sold individually • Fits Cat. No. No. allows in-line monitoring Cat. 5803 Cat. No. Nos. x 18mm I.D. 5567 Sensor for use in Siemens Servo 900A. No. No. 5811 Internal Oxygen Sensor • For use with Cat. Also used with Ventronics Cat.D. 5565 Sensor for use in Hudson RCI Cat.Replacement Oxygen Sensors and Tees Oxygen Sensors and Tee High quality replacement sensors accommodate a wide assortment of oxygen analyzers.D. 5590. 5803 Sensor • 22mm O. 5566 Cat. 1638 Cat. 1639 External Sensor Internal Sensor Disposable Tee Disposable Tee • Fits Cat. 5552. • All oxygen sensors are warranted for 12 months 5567 • Complete warranty information provided with each sensor or cell • Sold individually 5500 5565 5566 5587 Cat. 6477 • High performance galvanic fuel cell Sensor for use in Hudson RCI Cat.D. • Allows for in-line monitoring • Individually packaged 50 to a case • For use with Cat. No. x 22mm I. No. 900B and 900C ventilators Sensor for use in Catalyst Research MINIOX oxygen analyzers and Engstrom ERICA ventilator Sensor Tee • For use with Cat. No. 5810 • Sold individually 76 .D. x 22mm O.D. x 22mm O. 5500 Cat. 5525. 5803 sensor • 22mm O. x 18mm I. No. Nos. monitors and ventilators. • Allows for in-line monitoring • Individually packaged 50 to a case Cat.D. No. and more than doubles the life of an oxygen cylinder. 1850 Cat. • Includes one Cat. 2664 Adult Cannula Adult Cannula Carrying Bag • Oxygen conserving cannula with 5 feet oxygen tubing • Same as 1850 with 7 feet oxygen tubing • 25 to a case • Duffle style bag with shoulder straps for use with small cylinders • Sold individually • 25 to a case 77 . No. dial-in click-style flow control • 1-1/2 inch diameter contents gauge and gauge protector • Pass CGA E-4 ignition testing and meet ASTM standards • Flow rate accuracy within +/. these compact regulators feature an aluminum body with brass high pressure chamber. No. high pressure chamber and convenient click-style design • Switch to “continuous” mode with the push of a button • Manufactured and tested to new ASTM ignition test standard • CGA 870 connection • Does not require batteries • Flow settings 1/2 to 5L in 1/2 liter increments • Dimensions: 41/2 in. No. 1850 conserving cannula • Sold individually Monitors. hospital. • Aluminum body with all brass. homecare.10% of settings down to 1LPM. • Easy to use. No. 1851 Cat. and emergency applications.20% less than 1LPM • Two-year limited warranty • Sold individually Flow Range LPM CGA 870 Yoke Barbed Outlet 2041 (Mini) 0-8 2042 (Mini) 0-15 • • 2043 0-15 2044 (Mini) 0-25 • • • • Cat. Available in standard or mini-style. 2661 Delivers the prescribed liter flow on every inhalation. Regulators & Cylinders Oxygen Conserving Cannulas Cat.. Working pressure range: Maximum inlet pressure: Outlet pressure range: Operating temperature range: Storage temperature range: 500-3000 psi 3000 psi 57 psi +/. No. x 3 in. x 1 in.5 psi -20F to 150F -40F to 160 Diss Outlet • • Oxygen Conserving Systems Conserving Regulator Cat. weighs 20 oz.Oxygen Regulators Click-Style Oxygen Regulators Designed for pediatric. +/. and certified to all applicable industry and government standards Nut and Gland Style .CGA 540 Cat.CGA 870 Cat. diameter gauges Yoke Inlet Style . 2615 • 2-15 LPM flow range • 11/2 in. No. diameter gauges Swivel-Yoke Inlet Style .CGA 870 Cat. No. 2620 2615 • 2-15 LPM flow range • 11/2 in. and dual-filtered inlets • All regulators pass CGA E-4 ignition test requirements • Designed. diameter back-mount gauges • For use without a humidifier 2620 Regulators with Flowmeter • Backpressure-compensated thorpe tube flowmeter with 1-15 LPM flow range • 11/2 in. 2600 • 2-15 LPM flow range • 2 in. lexan gauge covers with highly visible numbers. diameter pressure gauge Nut and Gland Style . 2625 • CGA No.Oxygen Regulators Diaphragm Style Regulators • Precision-machined solid brass bodies. tested manufactured. • All oxygen regulators sold individually .CGA 870 Cat. neoprene diaphragm. No.CGA 540 Cat. 2660 • Same as 2625. No. 540 (shown) Yoke Inlet Style . but with CGA 870 yoke inlet 78 Hudson RCI Diaphragm Style Oxygen Regulators incorporate a flexible. No. 3” diameter cylinder well • Sold individually Cylinder wrenches sold individually. lightweight (7 lbs. No. 4046 Small Base Large Base M Cylinder Base • Base for D or E cylinder • Sturdy.Regulator and Cylinder Accessories Cylinder Wrenches Cat. Monitors. 5080 Cat.S.and E-sized medical oxygen cylinders Cat. 2555 Cat. stressresistant nylon • Fits adjustment stem on all CGA standard post valves for D.25” diameter cylinder well • Sold individually • Base for large H steel cylinder • Durable. anodized aluminum Cat.) cast aluminum design • 7. No.and E-sized medical oxygen cylinders • Made of tough. lightweight plastic design.I. No.375” diameter cylinder well • Sold individually • Base for steel cylinder • Lightweight (7. 4045 Cat. May be bolted to floor • 4. No. 5082 Large Cylinder Wrench • For large cylinder regulators • Made of rugged. No. 4040 Cat. threaded oxygen outlets • 50 per package • Gasket for small medical cylinders • 100 per package • Gasket for small medical cylinders and click-style regulators • Viton/brass • 10 per package Cat.5 lbs. No. Regulators & Cylinders 79 .) plastic design • 9. No. 2040 Nipple and Nut Adaptor Nylon Gasket Viton Seal • Barbed hose adaptor for standard D. No. 2540 Cat. 5083 Small Cylinder Wrench Small Nylon Wrench • Made of die cast zinc • Fits adjustment stem on all CGA standard post valves for D.S. No. Hospital Bed Cat. Holders.or E-sized aluminum or steel cylinder • Sold individually Cylinder Holder . No. No.Cylinder Trucks.or E-sized aluminum or steel cylinder • Sold individually Cylinder Holder “Wheeled” Cat. heavy-duty wheels and rubber handgrip • Sold individually 80 . 4012 Wheelchair Cylinder Holder • Made of chrome-plated tubular steel • Holds a single D.or E-sized aluminum or steel cylinder • Two 6-in. & Bases Cylinder Holder . No. 4009 Hospital Bed Cylinder Holder • Made of chrome-plated tubular steel • Holds a single D.Wheelchair Cat. 4000 • Made of chrome-plated tubular steel • Holds a single D. Division of Gambro Inc. Louis. and VIP – Viasys Healthcare. 5404. Germany BEAR 1. 5-20610. 8400ST. ADDIPAK AIR-EZE AQUA + AQUAPAK AQUATHERM AVA-NEB BI-FLO BITEGARD CATH-GUIDE CLEAR COMFORT CONCHA CONCHA-COLUMN CONCHAPAK CONCHATHERM CONCHATHERM III CORR-A-FLEX CORR-A-TUBE CPRAM FLEX-C-PAP FLEXIBEND GIBECK HUDSON RCI HUDSON RCI Logo ISO-GARD HUMID-VENT LAR-A-JECT LIFESAVER MICRO MIST MULTI-VENT NEB-U-MASK OXY-VENT SHER-I-BRONCH SHER-I-SLIP SHER-I-SWIV SHERIDAN SHERIDAN/CF SHERIDAN/HVT SMOOTH-FLO SOFTECH SPIRAL-FLEX STAR LUMEN SURE SEAL THERMAGARD TRACH-VENT UP-DRAFT UP-DRAFT II VENTI-COMP VOLDYNE Breathing. 81 . Toms River. Puritan-Bennett 2800. 4012. 1154 . 840. Manchester. Inc.1294. E 100i and BREEZE – Newport Medical Inc. Inc. 29200. CA VEOLAR. LP10. Sensormedics 3100A.1160 1271 . IVENT. Reno. Lubeck. Amadeus. STAR. 1001-50. IL “Distributed by” Products The following products are distributed by Hudson RCI. The few products which contain natural latex rubber have been noted. 4009.4046 5080 . 5421 . 900A. 1652 5400 . made easier The following are trademarks of Hudson RCI.. NH Servo 900.5082. 3. LP6. PLV-100 and PLV-200 – Mallinckrodt. 1801. Newport Beach. 5-20612 Hudson RCI is pleased to provide an extensive Latex-Free product offering. Belpre. NV VELCRO – Velcro USA. BIRD 6400ST. 5400 .Inc. Sacramento.5804.Trademarks The following are registered trademarks of Hudson RCI and Hudson RCI AB. 300. 5.MA-2. Schaumburg.1282. Palm Springs. 2. 4. Williamsburg. 4040 . and MA-2+2. Evita 2. MA-1. CA BABYLOG.2664 4000. 900C. 1805. E-150. 7200. 1002-50 Indexes & Notes Products Containing Latex The following products contain natural latex rubber that may possibly cause an allergic reaction. and DRAEGER – Draeger Medical. St. 5810. 15920.. NJ WAVE. 1669 15800 . 2700-105 15910. 5565-5567 5800 .. CA COMPANION. Owings Mills. 1890 1816-1839 2041-2044. and Advent – Siemens-Elema Ventilator Systems. 15911.5404 5500.. MD MONAGHAN 225 – Monaghan Medical Corp. OH MINOX – MSA Catalyst Research. MO ERICA – Engstrom. NY NAFION – Perma Pure.15810 1800. Raphael – Hamilton Medical Inc.5402. Galileo. 5811 1001-10. All anesthesia circuits containing a latex (blue) breathing bag. 2600 . ISO-NEB NEBTEE EZ-ENDO TRIFLO II The following are registered trademarks of the companies listed: AEROTEE – Piper Medical. 1000. 900B. 1002-10. 1603 1291 . Plattsburgh... VA KRATON – Shell Chemical Co.. 292015 5-20608.5425. ........................... 24 hyperinflation bags .............. 78 oxygen sensors .......... 68 temperature probes ............ 54 swivels ........................................................................................................................ 30.................... 64 drainage systems ..................................................5...................Alpha Index Product Name Page No...73 infant nasal CPAP cannulas ................................................................ 38 incentive spirometers .................. 58 suction catheters .......19 HUMID-HEAT system ................ 77 CONCHATHERM adaptors ............................ 8 gas sampling lines .......... 59 reusable resuscitation bags ..................... 38 isolation valves and kits ........................................................................................................................ 64 brackets .......................................................................................................................60 Mapleson D circuit ........................................ 5 tube exchangers ....................... 4 filters ........... 74 sterile water ........................................................................................................................................................................................... 69 MDI spacers & chambers ............................................................................................................................................... 67............................................................................................................ 77.......................... 48 masks ........................................... 4 aerosol tees ................................................. 5 chambers................... 32 ......... 60 reusable masks ..52 nebulizer adapters .............................. 24 ......................................38 ventilator hoses ..................................................................................................... 17 uncuffed endotracheal tubes ........................... 69 nebulizers ............. adaptors ......................................................... 48 face tents .................... 74 MDI adapters ..............................................................23 breathing bags .. 59 sampling lines ............ 78 reinforced endotracheal tubes ...... 21 connectors .. 55 tees ........... 22 .............................................. 79 nonrebreathing masks ................................. 27 trach masks .......................................... 9............................ 22 .... 44 mask harnesses .............................................13.......................................................................................................................................................... 6 ....... 48......................... 61 prefilled humidifiers ............................................................. 69 aerosol tubing ....................................................................................... 61 IMV system ............................................. 22.................................... 50 unit dose solutions ............................ 54 endotracheal tube holder ............................................................... 38 small volume nebulizers .......................................................... 21 CONCHATHERM heaters ... 15 preformed endotracheal tubes ......................... 62 oxygen analyzers ............................................................................................................ 3 trach HME ......................................... 10 air cushion masks .............................. 77 oxygen conserving regulator ................. 14 ....... 55 single-limb circuit ................................................................................................................................. 67 conserving cannulas ....................... 10 CPAP cannulas .............................. 50 PEEP valves ................................................................................................... 57 tubing ............................................ 53 modified Jackson-Rees .................... 62 Ovassapian airway ............................................................................................................................................ 35 pediatric endotracheal tubes ............................................................ 77 corrugated tubing ................................ 75 oxygen cannulas ................................................ 9 partial breathing masks ..................... 2 HMEs ..................................... 5......... 59...................................................................................................................... 22 regulators . 22 thermometer .....29 humidifiers .... 66 ............................................................... 20 CONCHATHERM probes ............. 74 click-style regulators ..... 11 .................................................................................. 18 ......................... 7........................... 23......................................................... 32..................... 3 airways ......... 17 neonatal adapters .. 65....... 47 gaskets and seals ...................................... 44 monitoring adapters .................................................................... 1 .................................... 77 oxygen kits .................................. 15 laser endotracheal tubes ........................... 72 ....... 57 exhalation valve ..............63 anesthesia breathing bags .................................................................... 64 CPRAM circuit ....................................................................................................................................................... 52...................................................................................................................................... 49 ......... 46 bubble humidifiers ...................... 20.............................. 6........................................... 77 conserving devices ............................................... 46 water traps .......................................................................... 6 catheters ..........29 heated humidification ....... microlaryngeal tracheal tubes ..................................................................................................................................................... 2 peak flow meter ......................... 22 CONCHAPAK ...................... 16................ 51 ...................... 55 manual resuscitators ........................... 53 resuscitation bags ...........................23 CONCHATHERM columns ...................................... 68 three-in-one masks ..... 70 face masks ........... 75........ 3 Nafion® tubing ......... 36................... 48 air entrainment masks .................. 47 Select-A-Vent masks .......... 66 emergency kits ........................................................................................................ 74 82 Product Name Page No...................................... 51 probes ......................................................... 77.......................45 Bain circuit ............................... 67 aerosol drainage systems ........................... 71 ventilator circuits .................... 29 Flex-C-Pap ................................. 7 oxygen catheters .............................. 55 gas sampling cannulas .............................. 68 oral airways ............ 67............................ 69 temperature monitoring tees .. 18 prefilled nebulizers ............................................................................... 74 pediatric circuits ................ 69 VENTI-COMP ..... 44 bite sticks and block ........................................................................ 59 ..................... 24 hepa filters ............................. 39 ............ 37 nipple & nut adapter ..................... 30 high concentration masks ........................................................................................................................................................................................................................................... 79 cylinder wrenches .............................................................................................................................................................. 21 stylets ................................................................................................. 23 CPR board ............................................................. 9 oxygen masks ..... 45 cylinder holders and bases ..........................................................................................................................................7 nasal tubes ............... 58 mouthpiece ............. 6...................... 11 ............................. 79 HCHs ............................. 1..................................... 76 oxygen tubing .............................15 nebulizer tees ................................................................................................................... 20 -24 heaters ....4 oxygen monitors ........................................................... 7................ 70 ultrasonic nebulizers ..................................................................................................................56 exchangers ............ 65...................... 71 aerosol masks ............................. 75 oxygen regulators ............. 14............................................. 14...... 68 wyes ...... 71 elbows .............. 31 flex tubes ......... 79 dental guards ....................... 24 ................................. 65 endobronchial tubes .............. 1.............................................................................. 70 CONCHATHERM brackets .. 67 mouth cushion .......................................................... 8 CPAP heater ........................................................ 6 oxygen conserving cannula ................................................................................................. 19 cannulas ........................................................... 1 ....................................................................................... MDI .............13 spacers .................... 47 nasal cannulas ................................... 58 endotracheal tubes ....................................... 8 IPPB circuit .............................................................. 10 tubing adapters ............................................................................................................................... 62 ........................................................................................................ 68 large volume nebulizer .................................. 17 valved tees ........................................... 69 neonatal circuits ........................................... 2 one-way valves . 3 Sher-I-Swiv ...................................................................................... 46 anesthesia circuits ................. 70 Multi-Vent mask ......................................................................................................................................... ............. 70 1570 ............ 31 Cat.... 45 13403-540 .................. 25 1112 ..... Page No................................. 14 044-70 ............. 5 11012 .... 38 1658 ... 48 1273 ....................................... 18 031-28 ......................................................................................................... 40 16003-944 ........................... 67 1410 ....... 63 1158 ..................................... 74 13200 ... 2 1009 ... 69 1409 ............................ 74 1293 ...... 17 093-00 ................................. 14 041-35 ............. 63 1171 ................................................................ 58 1066 .................. 28 1589 ..................................................................................... 41 1632 .................................... 48 15802 ................... 45 13403-951 ............................... 10 1528 ........................... 1607 .. 2 1061 ..... 28 1576 ............. 67 1641 ............... 18 006-40 .. 47 1234 .... 48 1581 ......................... 45 13202-951 ..... 47 126664 .... 66 1080 ........................................... 63 1159 ............................................................... 68 1181 ................................... 10 1518 ........ 14 044-33 ................. 48 15920 ..................... 28 1571 ............................... 63 1168 . 5 1147 ................................. 10 1413 ..... 62 Cat.................. 32................................................ 39 16322 ............................................... 7 1111 ............................................................................................. 48 1274 ......... 48 1275 .......... 65 1187 .. 1 10011 ... 47 1238 .................... 3 1098 .................. 63 1156 ................ 18 017-11 ....................................................... 3 1065 ........................................ 45 13202-665 .................... 44 1400550 ....................... 63 1150 ..................... 4 1388 ..................................................... 25 1001-10 ............................. 7 1104 ............................................................................................................... 14 040-45 .... 5 1148 ............ 65 1184 ..................................................................... 66 16320 .... 5 1103 ................................................... 10 1516 ........................ 1174 .......... 63 1160 ........................................................ 2 1035 ............................................................... 14 042-45 ...... 63 1166 ............. 68 1652 .................. 4 1088 . 32 1609 .............................. 74 1001-50 .............................................................................. 31 1606 ...... 18 004-00 ..................................................................................................... 69 1650 ....... 45 1400150 ............. 18 004-05 ................................................. 14 037-09 ..................................... 10 1416 .................. No..... 48 15911 ............................... 63 1157 ............................ 68 1659 ..................... 10 1417 ............................................. 31 1578 .................... 32 1617 ... 47 1232 ........................ 14 006-01 .... No....................... 74 1294 .................................. 29 15910 ........................ 48 1291 ........................................... 67 14412 ................ 45 13301-934 ....................................................................................... 45 13201-952 ........ 28 1572 ...... 47 1237 ............. 45 13400-951 .......................................... 69.................................................. No. 48 1277 ......................... 9 1127 ... 4 1083 ........................... 64 1178 ........... 2 1059 .. 68 1637 ............. 44 1510 .................................................................... 4 1085 ....... 14 037-28 .. 2 1060 .................................. 47 1236 ...................................... 28 1575 .............................. 17 051-90 . 3 1100 .................. 28 15800 ........................... 9 1124 ......... 32 1613 ............ 26 1102 .. 5 1076 ... 10 1418 .... 63 1149 ............ No...... 28 1590 ............................... 7 1109 . 64 1145 ........................................................................ 66 16412-BHS ... 67 1421 .......................................................................................................................... 45 13200-951 .................................... 65.................. 66 1625 ................. 1 1050 ....... 65 1230 ..................................................... 10 1140 ................ 63 1165 ........... Page No.. 18 000-40 ........................ 48 15804 ........................ 9 11132 ......... 48 1278 .................. 14 041-33 ...................... 28 1584 ..... 48 1276 ................................ Page No..... 45 13312 ............. 18 003-01 ...................................... 32 1608 ...... 44 1462550 .......... No.............. 14 040-00 .................... 45 13402-951 ..................................... 18 037-05 .......... 40 1161 .......... 45 13401-951 ............... 32 16303-944 ............................................................ 7 1108 .................. 10 1517 .. 48 15808 ............ 28 1577 ............... 47 1239 ................................................. 9 1120 ...... 7 1110 ....... 25 1456250 ................. 39 1603 ......... 65................ 68 1648 .............................................. 48 16003-579 .... 76 1639 ........................ 47 1235 ...................... 47 1233 ............. 63 1167 ................................................................................. 5 1101 ........... 28 1583 ................ 47 126613 .................... Page No...................... 63 1155 ....... 45 13201-951 ............. 1 1011 ........................................................... 74 1292 ................................ 43 1642 . 31 1605 ............. 48 15806 . 48 1279 ...... 68 1645 ...................................... 10 1132 ................................... 67 1647 ........................ 14............ 32 1610 ...... 10 1420 ......... 45 13201 ................................... 71 1560 ..................... 67 1423 .............................. 28 1579 .............. 15 037-00 ............ 48 1281 ......................................... 74 1002-50 .................................. 1 1042 ........................... 63 1169 .................................... 9 1130 .......................... 40 16010 ...... 48 1272 ....................... 14 048-91 ............. 14........................................... 10 1550 .......................... 14 037-39 ...................... 14 037-33 ....................................... 4 13900 ...................................... 45 13300-951 ....... 1385 .............................. 14........................... 17 1000 .......... 67 1422 .......................................................... 63 1154 .............. 45 13301-951 .. 18 003-40 .... 28 15810 ................................. 41 16303-951 .. 18 014-11 .................... 45 13300-944 ....................................... 70 1644 ................... 32 1623 ............. 10 1415 .... 45 13303-951 ....................................... 14 041-28 ............ 63 1173 ... Page No. 48 1280 .... 32 1614 ............. 65 1186 ............. 32 1627 ............................ 63 1164 ....................................................................................... 47 126263 .Numerical Index Cat. 1 1058 ................... 1075 ......................................... 45 13201-BQM .......... 64 1180 ............ 74 1002-10 ........................... 4 1084 .............. 28 1574 .... 44 1402 ................. 14 047-28 ........................................................................ 47 126713 ............ 14 037-35 ................................ 1 1041 ........................ 67 1643 ........... 38 1565 ............ 39 1635 ........ 69 1078 ...... 58 1069 ................................................................................................... 25 13400 ....................................................................................................................... 14 042-00 ........................................................................................................................................................................................ 28 1573 ........ 7 11112 .... 69.......... 63 116003-957 ............... 1 1049 ............ 69 Indexes & Notes 83 ................. 4 1096 .............. 68 1182 ........................ 47 125064 . 68 1638 ...... 38 1654 ............................. 15 031-33 ...................... 63 1170 ............ 14 044-28 .... 5 1077 ...... 65 1185 .. 63 1151 .................................................................................................................. 17 051-45 .............................. 16 050-12 ....................................... 14 044-35 ........... 1 1040 .................. 25 1115 ...... 47 1271 ..................................................................... 44 1400250 .... 14 047-35 ......... 74 1007 ......... 76 1640 ............... 66 1624 ...................................................... 3 1095 .................. 47 126463 ................................................................................... 32 1615 ....... 000-11 ....... 2 Cat....................... 3 1089 .......................................... 48 1282 ...... 32 1619 ...................... 45 13302-951 .......... 63 1152 ....................................................... 40 16003-951 .... 9 1118 ............................................................ 1 1048 .................................................................. 16 051-00 ................................ 48 1582 ......... 45 Cat................................................................ 40 16020 .................................... 9 1119 ... 14........... ........... 6 1823 ...... 29 1943 ........................ 6 1817 ........................................ 25 1790 . 17 2040 ..................... 29 200-31 ............... 13 1724 ....................................... 7 1921 .. 25 17732 .......... 30600037 ........................... 6 1821 .................. 26 1980 ................................ 9 1951 .......... 351413 .... No.............. 3020003907 ............. 38 1700 ......................................................... 3030002513 .................................... 30600400 ........................................... 6 1830 ................................................... 30600207 ..................... 7................................ 352483 .......................................................... 13 1712 ..................................... 30600263 ....................... 30600133 ...... 30600173 ............. 77 2041 .................................. 12 1740 ........... 43 3020001711 ....................... 30 1925 .......... 29 2540 .................. 352583 .. 30700030 ............................ 8 1692 .................................... 13 1792 .. 29 20011 .................... 67 1679 ........................... 1937 .......... 6 1838 ....... 8 1689 ...... 69 1755 ........ 69 1766 .................. 351213 ............ 3040004746 .. 8 1844 .. 26 1851 .............................................. 6 18400 ................................. 353801 ... 11 18902 .......... 351103 .... 351223 ............. 29 1800404 ........................................... 46 292015 ............ 30600014 .......................... 61 28002 ............................................................... 30 28012 .................................................. 3020004750 ............................................... 3 19402 ...................................... 69 1768 .............. 13 1713 ...................................... 42 3020002055 .... 3040002162 .. 74 1805 ........ 12 1706 .............. 3040005374 ................................ 3050005289 ......... 3040005505 ............. 79 2555 .................................................................. 30 29003 ................. 17 200-34 ............... 66 1920 ............. 30600219 ......... 68 1666 .......... 351400 ........................................... 313901 ..................................... 3030002716 ............................ 10 1683 ................................................... 66 1674 ............................................................ 67 1664 ........................................................ 30600099 ............................................................ 68 1665 ................................ 68 1667 .............. 40 3020002861 ............................. 41 3020002495 ...................... 3050005201 ............................................ 351500 ... 2 1936 .................................... 12 1732 ........................................................ 13 1714112 ................... 8 1691 ... 318200 .......... 8 1687 ...................... 3040005345 ................... 30600143 ......................... 17 200-69 ................... 352513 . Page No..... 351513 ........................... 351202 .................... 8 1690 ........................................................... 6 1827 . 351403 ... 30600105 ................. 3040005561 ....................... 7 1814 ........... 3020004609 ........................................................ 30600241 ........ 70 1668 ............... 9 1984 ...... 26 19932-BKH ................................ 353471 .. 12 1710 .................... 3040005539 . 3130 ............ 26 19402-BKH .. 66 18903 ........ 3020003635 .......... 30600135 ....................................................... 12 1763 .... 3 1940 .. 3260 .................... 3020005535 .... 354001 ....... 3040005506 . 8 1696 ........................... 15 84 Cat.............. 11 1890 ............................................... 2 Cat... 9 1952 ....................................................... 17 200-54 ........... 11 1886 ....... 12 1731 .. 353900 ................................................................. 77 2664 ................................ 43 3020002432 .................... 38............................... 8 1850 .. 3040004663 .............. 3020004110 .... 350153 ........................... 30600375 ..................................... 311203 ...................................................... 42 40 39 43 43 43 43 43 43 19 41 42 19 19 43 41 41 19 19 40 40 40 40 40 40 40 40 40 41 41 41 41 41 42 42 42 42 42 42 42 41 39 39 39 39 39 43 43 43 43 43 43 43 43 43 43 44 44 44 44 40 ........ 7 1812 ... 6 1824 ...... 30600070 ........................ 66 1678 .......................................................... 30600246 .. 79 2600 ..... 11 18832 ....... 30 28062 ................................ 11 1882 ............ 30600104 ............... 354007 . 353912 ....... 73 1751 .......................................... 8 1685 .. 351600 ......................... 351100 ..................... 1 1935 ....................................................................................................... 9 1928 .............. 351123 ............... 64 29200 ..................................... 352113 ........................................................................... 3020004414 ...................................................................... 12 1737 ....... 79 2041 ................. 9 19932 ............................................................................................................................ 40 3020002506 ............ 3020005172 ...... 3040005166 ...................... 30600360 ....... 7 19212 ... Page No......................................... 351133 ................ 3040005545 .......................................................................... 71 1742 .......................................... 351102 .......... 1660 .................... 77 2044 ................................... 354006 ....... 66 1675 ......... 6 1828 ................................................. 77 18502 . 353812 ...................... 40 43 39 43 40 41 41 43 43 43 40 43 40 41 40 40 40 39 40 42 42 42 40 41 42 41 40 43 42 41 42 41 41 41 40 41 42 42 41 40 40 40 42 42 39 41 41 42 41 41 42 41 42 40 39 40 41 41 39 41 42 Cat...................... 353911 ...................................................................................... 71 1743 .............. 30600271 ... 12 1734 .............. 46 18402 .. No............ 30 28052 ....... 26 1884 ........ Page No.............................. No...................... 40 Cat.............................................................................. 351112 ..... 67...................................................................................................... 30 28022 . 9 1930 ..................... 69 1744 ............................................ 350163 .... 46 180392 ........... 77 22362 .............................. 40 170232-970 ....... 7.......... 46 3020001214 ............. 78 2660 ............ 77 2043 ........................................................... 311403 ..................... 78 2620 ......... 353811 ............................ 3100 .. 352103 ............... 8 1695 .......... 8 1694 .. 9 1953 . 353802 .. 3040000630 ............................... 13....... 70 1800402 ............... 69 1765 .......... 77 18660 ................................................ 77 2700-205 ........................................ No.......... 41 3020003564 ................................................. 11 1888 ................................................ 30600060 ................................................................. 39 3020002670 ............ 9 1981 ................... 10 1880 ..................................................................... 6 1820 . 11 1883 ..................................... 74 1810 ................................................... 17731 ............................................... 77 2042 .............................................. 66 1662 .. 17 200-39 ...... 7 1816 ........................... 318202 .. 9 19502 ........................................................... 68 1680 .......................... 30600127 ...................... 6 1826 ............... 70 1669 .................................................... 30600258 ......... 66 1661 .. 66 1663 .............. 3040005371 .... 9 1954 ................ 69 1764 .... 351200 .... 30600324 ...................................................................................................... 351423 ..................................... 3030003839 ... 6 1825 .............. 78 2625 ........... 67 1770 .. 351503 ........ 356113 ........... 17 200-51 ............................. 30700112 ........................... 3040001506 .................................................................Numerical Index Cat..................... 30700035 ................ 30600120 .. 46 1801 ................................................................. 351203 ..................... Page No.. 30600018 .................. 11 1881 ................ 6 1831 ............................ 30700104 .... 8 1688 ..... 354103 ......................................................... 3040004660 ........ 30600165 ............ 6 1837 ......... 6 1839 ........... 3040005090 ........ 3040003043 .............. 3030003837 . 67 1673 ...................... 3040005666 ................. 30700110 ................................... No........ 26 1843 ............................................ 8 1845 . 3040005432 ................... 69 1750 ...................... 13 1730 ........... 6.............. 29 180391 ............. 6 1818 ..................... 30600196 .................................. 3020004860 .............................................. 9 1982 .................................................. 30700010 ........................ 78 2661 ........................ 43 3020002605 ............. Page No.. 17 200-59 .... 67 1769 .. 353901 .................................. 353800 ............ 351113 ...................... 78 2615 ......... 9 1927 ........................................................................... 3040005609 ..... 8 1693 ......... 6 1822 ... 13 170032-596 ..................................... 9 1983 ............................. 3 1950 ..................................................................................................... 39 1705 .................. 3131 ................................................................ 6 1819 .. 3020004123 ............... 40 170032-951 . 8 1686 ............................................. 30600112 ........... 38................ 11 1885 ............... 12 1707 .............. 43 1720 ......................... 3230 ......... 22...................... 79 4046 ........ 51020 .......................... 23 386-54 ......... 386-58 ........ 24 37110 ............. 22 386-82 .... 24 371103 ..... 24 50470 ............ 24 37160 ...... 22 380-90R . 59 50471 ............................. 5-16000 ..................... 23 386-69 . 79 4045 .......................... 22 380-92 ..... 5-12009 ................................... 21.............................. 24 37184 ............. 5-11718 .... 5-10410 ................ 5-10413 .......... 40 371113 ................. 5-10206 ..... 5-10407 ..... 42 358103 ................... 21 384-00 .... 23 386-72 .... 24 37185 ..................................................... 5-10110 ............. 21 385-40 .................. 5-11714 .................. 5-10412 ......................... 5-15401 ........ 24 381-52 .... 23 386-65 ................................................................................................................................ 40 371413 ...................................................................................... 50473 .. 5-10113 ............. 5-10217 ............... 5-10511 ............................................. 24 386-91 .......................................... 5-15120 ............................................................... 23 386-84 ....................................... 68 391103 ............... 5-12007 ...................... 46 37101 .................... 59 59 59 59 79 79 79 59 59 59 59 59 59 59 59 59 49 49 49 49 59 49 49 49 49 49 49 49 49 49 49 59 49 59 59 59 59 59 59 59 59 49 49 59 49 49 49 49 49 49 49 49 49 59 49 59 59 49 49 49 49 Cat........... 5-12517 ........... 5-10219 ..................... 22 386-79 .............................. 22 386-50 ... 5-10411 ................................... 52 52 52 52 52 52 52 52 52 52 52 52 52 52 58 58 58 58 58 58 55 55 55 54 54 54 54 54 54 54 54 54 54 54 59 52 Indexes & Notes 85 . 80 4040 ....... 5-16037 ....... 5-10508 .. 5190 . 51014 .. 5-12612 ................................. 40 391203 . 5-11112 ............ 5-12613 .................... 20 400-20 ...... 5-12614 ....................... 21 385-70 ......................................................................... 23 386-55 ....................................... 70 385-20 ................................................ 5-10214 ...... 5-12617 .......... 5-15103 . 5-12515 ........... 5-15301 ... 5080 ................................... 5-10514 . 24 377143 ............................... 5-12908 ........................................................... 23 386-70 ........... 5-10216 . 5-10117 ......... 23 500-60 ............... 5-11406 ......................... 5-12615 .................................................................... 41 357113 ....................................................... 5-10509 ................ 22 386-49 . 24 37182 ................................................................. 23 386-75 ................................... 51019 ............. Page No.......................... 50476 .. 22 386-81 ........ 5-15110 ................ 5-10512 ........................................................................... 41 391213 .................... 59 Cat................ No......... 5-10106 ........................ 5-15100 ...................................................... 5-12006 ...... 24 386-89 .......... Page No............................... 5-12406 ... 5-10313 ............................ 27 400-50 ........................ 21 386-00 ...... 5-10212 .......................... 59 50472 ........................... 5-12906 .... 40 371193 . 5-12010 .................................. 23 386-64 ...................................................... 50474 . 22................. 5-10315 .................. 23 500-71 ................................................................................ 5082 ....... 5-10320 ............ 5-10506 ........................ 5-10513 ....... 5-11108 ......................................................................... 40 359103 .. 5-16128 ............... 51009 . 5-10109 ...................... 51012 ................................................. 5-10310 ....................... 22 386-73 ........... 5-10316 ........................ 5-16039 ............ 20 500-00 .............................................. 51023 ..... 5-15101 .... 51013 ............. 51021 ....... 5-16035 ................................ 23 Cat... 5-11405 ................................. 51011 ........ 24 37130 ....................... 22............ 5-16141 ............ 41 357413 ...................... 23 386-85 .... 5-10404 ....... 5-16028 ............................................... 5-10408 ....................... 5-12518 ............... 70 384-10 ..... 22 380-93 .............................. 5-12910 ..... 22 386-74 ............ 24 500-43 . 67 380-80R ........................... 5-12510 ...... 22 386-78 ...................................... 24 386-87 ........................ 23 386-52 ................... 5-12408 .............. 70 384-26 .. 24 386-90 ................................ 24 500-30 ...... 5-10108 .. 22 386-66 ........................................ 5-10505 ...................... 5-10409 ...................................... 5-12909 ............... 5-10220 .................. 5-10311 ............... 5-10314 ........... 51002 ................................................................... 22 381-50 ..................................................... Page No............. 23 386-56 ........................... 23 500-50 ..................................................... 21 381-55 ......... 40 357203 ................ 5-11408 .......................................... 5-12907 ........................ 21 381-53 .......................... 27 41312 ............................................ 5-10116 ............... 51005 ..................... 5-12409 .......... Page No.............................. Page No... 22 386-63 ... 5083 ..................................... 40 380-74 .... No........................ 51008 ........ 5-11410 ........................... 5-10318 ................................ 40 391113 .......................................... 5-10112 ..................................... 5-10510 ...... 5-12513 . 5-11407 ................................................................... 22 380-89L ..... 24 388-28 .................................................... 5-10111 ................... 51017 .......................... No..................................................................................................... 51018 ............................. 43 4000 ............ 22 386-09 .............. 5-12008 . 50475 .......................... 51003 ............. 5-12610 . 46 360600 ........................................................... 5-10215 .......................... 23 386-57 ....... 5-11716 ....................................................................... 80 400-00R .......... 41 393911 ............................... 5-10210 ......................... 5-12611 ........................ 5-10507 ................................. 5-10107 ....... 23 386-86 ............. 21 385-30 .......................................................................... 40 359113 ... 5-16041 ................. 5-16135 .. 79 41112 ............................. 5-10115 ...................................................................... 24 500-72 ................................................. 23 500-10 ........ 23 386-10 .......................... 51024 ...... 5-16142 ... 5-11110 . 5-12005 ....... 5-10312 .... 51004 .. 49 49 49 49 49 49 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 53 53 53 56 56 56 56 56 56 56 53 53 53 56 56 56 56 56 56 52 52 52 52 52 52 52 52 52 52 52 52 52 52 Cat. 51007 ............................. 24 500-73 ............................................................................... No....................................... 20 380-91 .................................. 5-12511 ......................................................................................................................... 24 37180 ............ 5-12407 ........ 5-10114 .................. 5-10504 . 20 400-10 ................................................ 22 386-83 ....... 51006 ..................................... 24 37187 ..... 5-10119 ......................................... 5-10218 ................................................ 5-10406 ............ 27 41172 ... 21 381-51 ............... 20 380-88R ............. 5-19010 .......................................................................... 20 380-89 .......................................................... 23 386-53 .... 22.......... 5-10208 .... 22 386-76 .................... 5-10213 ........................... 5-11409 ............ 24 37170 .......... 40 360400 .. 42 37152 ............ 21 385-60 ......................... 70 390-45 ....... 5-12616 ................................................ 27 45512 .................................... 5-12410 ................ 51016 .................... 5-16139 ...... 5-11404 ......... 5-10414 ......... 5-10317 ................... 51000 ...................................... 5-10405 ..... 23 500-15 .............................................Numerical Index Cat..... 5-10118 ...................... 5-12618 ............................... 22 386-77 .................................................... 23 386-51 ...................................................................................... 356213 ........... 22..... 51022 ......................................................... 20 4009 .......... 24 500-20 ...... 22 386-71 ........................................... No.............. 5-12516 ........... 80 4012 ............................. 51015 ............. 5-10120 . 5-12514 ......................................................................... 5-12512 .................................................. 22 386-40 ....................... 5-16137 ................... 5-15102 ......... 46 360410 ......................... ............................................... 5-22212 ................ 5-22014 ...... 33 780-21 ......... 5-22515 ...... 5192 ... 5-22210 .............. 61 5385 .......... 37 780-06 ......................... 37 780-19 ............ 62 BD7145 ........................ 5-30404 ..................... 5-22315 ... 37 780-05 ............................. 5-30513 ...... 5-22013 .................... 33 780-40 .................. 5-22214 ................... 35 Cat............................................ 5-20513 ....... 5-22512 ................ 46 5433 ...... Page No.. 51 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 57 57 57 57 57 57 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 59 59 59 59 59 59 59 60 60 60 60 60 60 60 60 60 Cat............. 5-22008 ..... 46 5500 ....... 5-30406 .. 5-30505 ........................................................ 46 5431 ............... 5-22517 .... 60 5380 ...................................................... 35 780-22 ............. 33 780-32 ....... 5-22106 .......... 5-30509 ......................................................................................... 5371 ............................................................... 39 780-02 ............. 5-22410 ............... 5-21515 .............................. 33 780-36 ........................ 5-22216 ................... 75 5801 ... 5-22109 .... No............... 35 780-30 . 5377 ............ 75 5803 ... 5-19016 .................. 5367 ..... 61 5402 .......... 76 5804 .......................................................... 5-30504 .............................................................. 5-22510 ...................................................................... 5-22511 .......................................................... 37 780-51 .................... 5-22514 ....... 5-30411 . 75 5811 ............................................................... 5-20517 ..................... 5-22411 ......................................... 70 5614 ................ 35 780-23 ..................................................... 5-22114 ...................... Page No. 5374 ................................... 37 780-42 ....................... 5-21517 ........................................ 86 52 52 52 52 52 59 59 59 59 59 56 56 56 56 56 56 55 55 55 54 54 54 56 56 56 56 56 56 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 51 Cat.............................................. 44 7147 ............................... 5-22211 ........................... 76 6060 ...... 61 5421 ................. 5-22215 .............. 5-22407 .......................... 27 690-30 ............................... 36 780-03 .............................. 5-30414 ............................................. 44 BD6075 ................ 36 780-04 ........ 46 5422 .. 5-22012 .................... 5-22006 ......... 36 780-07 .................... 73 8884717301 ............................................ 5-19015 ............................. 46 5423 ................. 5-22406 ...................... 5-22312 ........ 72 8884719017 .............. 5-20515 ......................................... 75.... 36 780-13 ................ 9 9001 ................ 5191 .... 5342 . 5-30412 . 5-24000 .... No..... 44 G1441-BKH ................... 5-22007 ............................................................ 5-22111 .................................................................................................... 5-22209 .. 60 5400 ............. 5-22213 .............. 5-19012 ........ 5-22110 .. 5-22513 ..... 37 780-41 ............................................................................ 72 9000 ......... 5-30506 .............. 5194 ............. 44 BD2491 .......................................... 5-22010 .. 5-19014 .......... 5-20710 ............................................................ 5-22518 .......................................................................................... 60 5383 .......... 5362 .. 33 780-35 .............. 35 780-25 . 5-30514 .... 33 8884715700 .................................. 5-24105 ........................................ 5-30507 .............. 61 5401 ............................................................................................................................ 5369 .............................................................. 36 780-12 ...................... 19 61112 ............ 37 780-43 ............................ 5-30410 ............................... 5-20712 .......... 5-24006 .. 5-20708 ...... 5-22208 .......... 5-30405 ....................................................................................................................... No......... 9 9059 ................. 76 5567 ....... 5193 ............. 5-22107 .............. 5341 .......... 36 780-11 ............................................. 5-30508 .................................................. 5-22011 .............. 5361 ..... 5366 ......... 5-22316 .................... 5-21512 ......................................... 5-22112 ............................. 46 5425 ......................................................................... 5-22113 .................................. 5-21514 .......................................... 70 5705 ............................ 46 5432 ....... 5-30512 ............................ 35 780-24 .................... 5-19013 ..................... 5336 ................ 37 780-10 .............................. 61 5387 ................................ 37 780-14 ..................................................................... 5-22313 ..... 5-21513 ... 37 780-15 ............. 5-22217 ........... 5-30413 ..................... 41 7145 .......... 32 690-50 ............................. 33 780-34 ...................................................... 16 5800 ............. 5345 .............................. 5-22405 .. 46 5435 ......... 76 5566 ............ 44 BD2494 . 61 5403 ..................... 33 780-33 ........ 5-20610 ....................... 5-30510 ........................................................................ 29 ...... 73 8884719009 .......... 5-21516 .............................. 44 BD2498 ............................... 5-24205 ............... 72 8884719025 ...... 34 790-32 ................................ 5-30407 ....... 76 5612 ......... 5-22409 ............................................. 5-24002 ....... 5-22108 .................................................................... 32 7140 ............. 5372 .. 5347 ....................................................................... No......................................... 76 5587 .. 5-20608 ....... 67 BD02492 ... 5-20612 ....................... 5-20514 .... 61 5404 .. 5-22408 ... 5364 ......... 5-20512 .............................. 5-30409 .......................... 5-20516 .................. 5-22314 .............. 5-22516 ...................................... Page No. 75 5802 ...................................................... 5-30511 ...... Page No........................ 76 5565 . 32 690-40 ......... 5-22009 ....... 5340 .... 780-31 ......................................... 5-24004 ......... 5195 ............................................ 76 5810 ............... 5-22218 ................. 5346 ........... 5-30408 ...Numerical Index Cat.......................................................................................................................................................... 33 780-20 ..............................................................
Copyright © 2024 DOKUMEN.SITE Inc.