Huawei VDSL Outdoor

March 19, 2018 | Author: Raheel Ansari | Category: Power Supply, Hvac, Electric Power System, Ac Power Plugs And Sockets, Alternating Current


Comments



Description

F01S100 V100R001Product Description Issue Date 01 2009-10-28 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China http://www.huawei.com [email protected] Website: Email: Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are the property of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but the statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. F01S100 Product Description Contents Contents About This Document.....................................................................................................................1 1 Product Feature...........................................................................................................................1-1 1.1 Prominent Security Performance....................................................................................................................1-2 1.2 Prominent Protection Performance.................................................................................................................1-2 1.3 Easy Installation..............................................................................................................................................1-2 1.4 Prominent Monitoring and Maintainability.....................................................................................................1-3 1.5 Compact and Reliable Structure......................................................................................................................1-4 2 Product Structure........................................................................................................................2-1 2.1 Appearance and Dimensions...........................................................................................................................2-2 2.2 Structure..........................................................................................................................................................2-2 2.3 Power System..................................................................................................................................................2-4 2.3.1 AC PDU.................................................................................................................................................2-6 2.3.2 AC Single-phase Lightning Protection Bar............................................................................................2-7 2.3.3 Battery....................................................................................................................................................2-8 2.3.4 Battery Heater........................................................................................................................................2-9 2.3.5 Remote power supply.............................................................................................................................2-9 2.3.6 DC PDU...............................................................................................................................................2-10 2.4 Cable Distribution Device.............................................................................................................................2-10 2.4.1 MDF.....................................................................................................................................................2-10 2.4.2 ODF......................................................................................................................................................2-12 2.5 Temperature Control Unit.............................................................................................................................2-13 2.6 Monitoring System........................................................................................................................................2-14 2.6.1 Monitoring Scheme..............................................................................................................................2-14 2.6.2 Sensor...................................................................................................................................................2-15 3 System Configuration...............................................................................................................3-1 3.1 F01S100 cabinet Configured with the MA5610.............................................................................................3-2 3.2 F01S100 cabinet Configured with the MA5616.............................................................................................3-2 4 System Parameters.....................................................................................................................4-1 5 Environmental Specifications..................................................................................................5-1 6 Standards Compliance..............................................................................................................6-1 Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. i Contents F01S100 Product Description 7 Acronyms and Abbreviations..................................................................................................7-1 ii Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Issue 01 (2009-10-28) ...................................2-5 Figure 2-4 Appearance of battery.......2-15 Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co..........................................................................................................................................................................2-3 Figure 2-3 Power distribution scheme of the F01S100 cabinet......................................................................................F01S100 Product Description Figures Figures Figure 1-1 The installation of the F01S100 cabinet ..................................................................................................................................... iii ................................................................................................................. Ltd...........................................................................................2-13 Figure 2-7 Monitoring scheme of the F01S100 cabinet..........1-3 Figure 2-1 Appearance and dimensions of the F01S100 cabinet................................................................2-2 Figure 2-2 Structure of the F01S100 cabinet...............................2-11 Figure 2-6 Appearance of the ODF in the F01S100 cabinet..2-14 Figure 2-8 Appearance of the door status sensor...................2-8 Figure 2-5 Appearance of the MDF in the F01S100 cabinet.......................................... . ....................................................................................2-4 Table 2-3 Specifications of the lightning arrester............................................................4-1 Table 4-2 Weight of the F01S100 cabinet...................................................F01S100 Product Description Tables Tables Table 2-1 Structure of the F01S100 cabinet (configured with the AC-powered MA5610/MA5616).............................................................................2-7 Table 2-5 Technical specifications of the AC single-phase lightning protection bar...3-2 Table 3-2 Number of subscribers supported by the F01S100 cabinet in different configurations...................................................................................................4-1 Table 5-1 Environment specifications of the F01S100 cabinet.2-11 Table 2-10 Specifications of the ODF.........................................................................................6-1 Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.............................................................................................................................................................................4-1 Table 4-3 Power of the F01S100 cabinet..................................................................2-7 Table 2-6 Technical specifications of battery............................................................................3-2 Table 4-1 Dimensions of the F01S100 cabinet...................................................... v ............2-13 Table 2-11 Technical parameters of the heat dissipation fan.................................................................................................................................................................................................................................2-8 Table 2-7 Technical specifications of the battery heater..........................5-1 Table 6-1 Standards compliance of the F01S100 cabinet..............................................2-9 Table 2-8 Technical specifications of the remote power supply.... Ltd......2-6 Table 2-4 Technical specifications of the maintenance socket.......................2-14 Table 3-1 Number of subscribers supported by the F01S100 cabinet in different configurations.........................................................................................2-4 Table 2-2 Structure of the F01S100 cabinet (configured with the DC-powered MA5610/MA5616)........2-10 Table 2-9 Specifications of the MDF in the F01S100 cabinet............................. . Related Version The following table lists the product version related to this document.F01S100 Product Description About This Document About This Document Overview The F01S100 cabinet can hold the MA5610 and MA5616. The F01S100 cabinet is a smallcapacity device that can provide the LAN. and VDSL2 services for the subscriber. product structure. Product Name MA5610/MA5616 Version V800R307 Intended Audience The intended audience of this document is: l l l l l l l Network planning engineers Installation and commissioning engineers Field maintenance engineers Network monitoring engineers System maintenance engineers Data configuration engineers Application developers Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd. ADSL2+. system configuration,system parameters,environmental specifications,standards compliance and acronyms and abbreviations of the F01S100 cabinet. This document describes the product feature.. POTS. 1 . . Symbol Description Indicates a hazard with a high level of risk which. and lighting protection. and parameters of the F01S100 cabinet. Ltd. Issue 01 (2009-10-28) . configuration and environmental parameters of the F01S100 cabinet. if not avoided. The configuration of the F01S100 cabinet. and structure of the F01S100 cabinet. 1 Product Feature 2 Product Structure 3 System Configuration 4 System Parameters 5 Environmental Specifications 6 Standards Compliance Describes. They are defined as follows. will result in death or serious injury. power system. The security performance. The standards that the F01S100 cabinet complies with in terms of environment. Chapter.. if not avoided. 2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. or unexpected results. weight.. Indicates a potentially hazardous situation that. could result in minor or moderate injury. data loss. structure. protection performance. The environmental parameters of the F01S100 cabinet.. power consumption. 7 Acronyms and Abbreviations Conventions Symbol Conventions The following symbols may be found in this document.. The appearance. if not avoided. could cause equipment damage. The dimensions. and performance degradation. Indicates a hazard with a medium or low level of risk which. The following table lists the contents of the document. installation method. Indicates a tip that may help you solve a problem or save your time. The acronyms and abbreviations used in this document. and the functions of the components. structure.About This Document F01S100 Product Description Organization The F01S100 cabinetis an indoor and front access cabinet of a small capacity. Names of files. Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. log in as user root. and dialog titles are in boldface. menus. Multi-level menus are in boldface and separated by the ">" signs. 3 .. } [ x | y | . Optional alternative items are grouped in square brackets and separated by vertical bars. directories. One or none is selected. click OK. ] { x | y | . Alternative items are grouped in braces and separated by vertical bars. For example.. Ltd. folders.. tabs. For example. Command arguments are in italic. For example. choose File > Create > Folder. GUI Conventions Convention Boldface > Description Buttons. and users are in boldface. General Conventions Convention Times New Roman Boldface Italic Courier New Description Normal paragraphs are in Times New Roman.F01S100 Product Description About This Document Symbol Description Provides additional information to emphasize or supplement important points of the main text... Terminal display is in Courier New. A minimum of one or a maximum of all can be selected. Items (keywords or arguments) in square brackets [ ] are optional. One is selected. parameters. Command Conventions Convention Boldface Italic [] { x | y | . Book titles are in italics.. window.. Alternative items are grouped in braces and separated by vertical bars. } * Description The keywords of a command line are in boldface. Issue 01 (2009-10-28) . For example. Therefore. Key 2 Mouse Operation Action Click Double-click Drag Description Select and release the primary mouse button without moving the pointer. pressing Ctrl +Alt+A means the three keys should be pressed concurrently. Press the primary mouse button twice continuously and quickly without moving the pointer. For example. Update History Updates between document versions are cumulative. press Enter and press Tab.. Key 1. pressing Alt. For example. A means the two keys should be pressed in turn. Press the keys in turn. Press and hold the primary mouse button and move the pointer to a certain position. the latest document version contains all updates made to previous versions. Updates in Issue 01 (2009-10-28) This is the first release. Press the keys concurrently.About This Document F01S100 Product Description Keyboard Operation Format Key Key 1+Key 2 Description Press the key. 4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd. F01S100 Product Description 1 Product Feature 1 About This Chapter Product Feature This topic describes the security performance.1 Prominent Security Performance The F01S100 cabinet features prominent security performance to comply with the international safety standards. 1. protection performance. installation method. monitoring. on a pole. 1. 1. and structure of the F01S100 cabinet. 1.2 Prominent Protection Performance The F01S100 cabinet features prominent protection performance to meet the requirements of the outdoor or the indoor environment that does not have any protection.5 Compact and Reliable Structure The compact design of the F01S100 cabinet facilitates the installation of the F01S100 cabinet and ensures that the F01S100 cabinet runs reliably. 1. Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. or on a concrete pedestal. maintenance.3 Easy Installation The F01S100 cabinet can be installed on the wall. Ltd. 1-1 .4 Prominent Monitoring and Maintainability The structure of the F01S100 cabinet meets the requirements of real-time monitoring and easy maintenance.. but the amount of dust that enters the cabinet does not damage the device. During the installation. l l 1.1 Product Feature F01S100 Product Description 1. As a result. the cabinet cannot completely prevent dust from entering the device. l The F01S100 cabinet features prominent protection performance and anti-attack performance. The F01S100 cabinet uses the HW-2802A lock to secure the cabinet door and serve as an anti-theft measure. Ltd.1 Prominent Security Performance The F01S100 cabinet features prominent security performance to comply with the international safety standards. The wall mounting installation parts of the F01S100 cabinet enable you to install the F01S100 cabinet on the wall that has the surface differences smaller than 10 mm. or on a concrete pedestal. l The F01S100 cabinet has firm mounting brackets on its top and thus can be hoisted in a safe and reliable way. l When the F01S100 cabinet is configured with the MA5610/MA5616 (device that uses the forced air cooling mode for heat dissipation). Issue 01 (2009-10-28) . l 1. The first number "5" refers to the class for preventing the solid particle from entering the device.. That is. the F01S100 cabinet provides the IP protection rating of the integrated device reaches IP55 ("IP" refers to International Protection.2 Prominent Protection Performance The F01S100 cabinet features prominent protection performance to meet the requirements of the outdoor or the indoor environment that does not have any protection. That is. The F01S100 cabinet can be easily installed. The built-in external line protection unit (optional) and the service boards provide 2-level protection for the service ports and meet the requirements of the K-45 protection index.). l l Figure 1-1 shows the installation of the F01S100 cabinet 1-2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. the water sprayed from different directions to the cabinet does not damage the device. you can use the marking-off plate to determine the installation position of the cabinet. you need to carry the cabinet only once. The built-in lightning arrester in the AC PDU or AC single-phase lightning protection bar protects the AC power supply.3 Easy Installation The F01S100 cabinet can be installed on the wall. The F01S100 cabinet provides a marking-off plate. The second number "5" refers to the class for preventing water from entering the cabinet. This lowers the risk of installing the cabinet. on a pole. Ltd.4 Prominent Monitoring and Maintainability The structure of the F01S100 cabinet meets the requirements of real-time monitoring and easy maintenance. 1-3 .F01S100 Product Description 1 Product Feature Figure 1-1 The installation of the F01S100 cabinet 1. Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. battery (optional). Issue 01 (2009-10-28) . it integrates the AC-powered MA5610/MA5616. and major alarms of the remote power supply in real time to support the remote alarming function.. The F01S100 cabinet can be installed quickly on site to meet the requirement for quick deployment. MDF.5 Compact and Reliable Structure The compact design of the F01S100 cabinet facilitates the installation of the F01S100 cabinet and ensures that the F01S100 cabinet runs reliably. The F01S100 cabinet can be installed quickly on site to meet the requirement for quick deployment. The F01S100 cabinet (configured with AC-powered MA5610/MA5616) provides an AC power socket to supply power to the maintenance terminal and implement on-site maintenance. l When the F01S100 cabinet configured with the AC-powered MA5610/MA5616. lightning arrester (optional). Ltd. remote power supply. l l 1-4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. When the F01S100 cabinet configured with the DC-powered MA5610/MA5616. The ventilation design of the F01S100 cabinet can ensure that the F01S100 cabinet runs reliably in the outdoor or indoor environment when the F01S100 cabinet is not configured with any air conditioner. DC PDU and enhanced heat dissipation module (optional). it integrates the DC-powered MA5610/MA5616. AC PDU. battery heater (optional) and enhanced heat dissipation module (optional). door status. optical distribution frame (ODF). l 1. ODF. main distribution frame (MDF).1 Product Feature l F01S100 Product Description The F01S100 cabinet monitors the states of the internal ambient temperature. heat dissipation fan (optional). Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.6 Monitoring System This topic describes the monitoring scheme and the built-in sensors of the F01S100 cabinet.4 Cable Distribution Device The F01S100 cabinet is configured with the built-in MDF and ODF. 2. 2.. and related technical parameter of the F01S100 cabinet. The ODF is used to connect the optical fiber and the optical communication device. Ltd.2 Structure This topic describes the structure of the F01S100 cabinet when it is configured with different devices. It can also use the remote power supply to support the DC-powered MA5616/MA5610. 2. 2. 2. The MDF is used to connect the internal subscriber cable and the external subscriber cable. 2-1 . 2.F01S100 Product Description 2 Product Structure 2 About This Chapter Product Structure This topic describes the appearance.1 Appearance and Dimensions This topic shows the appearance and dimensions of the F01S100 cabinet. structure.5 Temperature Control Unit This topic provides the technical parameters of the built-in temperature control unit used in the F01S100 cabinet. component function.3 Power System The F01S100 cabinet uses the optional AC PDU or AC single-phase lightning protection bar to support the AC-powered MA5616/MA5610. 2 Structure This topic describes the structure of the F01S100 cabinet when it is configured with different devices. Issue 01 (2009-10-28) . Figure 2-1 Appearance and dimensions of the F01S100 cabinet 2.2 Product Structure F01S100 Product Description 2. 2-2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.1 Appearance and Dimensions This topic shows the appearance and dimensions of the F01S100 cabinet. Ltd.. Figure 2-1 shows the appearance and dimensions of the F01S100 cabinet. The F01S100 cabinet supports up to 256 narrowband lines. The F01S100 cabinet provides the excellent cabling management function. the AC-powered MA5610/MA5616 must be installed at the outermost 2 U position to facilitate heat dissipation and future maintenance. l l l Figure 2-2 Structure of the F01S100 cabinet Configured with the AC-powered MA5610/MA5616 Table 2-1 shows the structure of the F01S100 cabinet configured with the AC-powered MA5610/MA5616. which is the largest capacity for the products of the same type in the industry. Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. which is as quiet as in a library. Figure 2-2 shows the structure of the F01S100 cabinet. Ltd.F01S100 Product Description NOTE 2 Product Structure The F01S100 cabinet provides a space of 4 U for installing devices and can be configured with the following devices: l l One AC-powered MA5610/MA5616. The advantages of the F01S100 cabinet structure are as follows: l The F01S100 cabinet can be installed and maintained from its front. the DC-powered MA5610/MA5616 must be installed at the outermost 2 U position to facilitate heat dissipation and future maintenance. Cables and boards can be installed or removed easily. The noise is lowered to 35 dBA at nights. The low-noise design is excellent. One DC-powered MA5610/MA5616 + one remote power supply + one DC PDU. During installation.. 2-3 . During installation. the DC PDU must be installed at the inmost 1 U position. It can also use the remote power supply to support the DC-powered MA5616/MA5610. Table 2-2 Structure of the F01S100 cabinet (configured with the DC-powered MA5610/ MA5616) Item Service device Power system Cable distribution device Temperature control unit Monitoring system Component Name One DC-powered MA5610/MA5616 Remote power supply / DC PDU l l MDF ODF Enhanced heat dissipation module (optional) Sensor (optional) 2. Ltd.. Figure 2-3 shows the power distribution scheme of the F01S100 cabinet 2-4 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.2 Product Structure F01S100 Product Description Table 2-1 Structure of the F01S100 cabinet (configured with the AC-powered MA5610/ MA5616) Item Service device Power system Component Name One AC-powered MA5610/MA5616 l l l AC PDU Battery (optional) Battery Heater (optional) MDF ODF Cable distribution device Temperature control unit Monitoring system l l Enhanced heat dissipation module (optional) Sensor (optional) Configured with the DC-powered MA5610/MA5616 Table 2-2 shows the structure of the F01S100 cabinet configured with the DC-powered MA5610/MA5616. Issue 01 (2009-10-28) .3 Power System The F01S100 cabinet uses the optional AC PDU or AC single-phase lightning protection bar to support the AC-powered MA5616/MA5610. 2-5 .3 Battery Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.3. Ltd.1 AC PDU This topic describes the power distribution scheme and the related technical specifications of the built-in AC PDU (optional) in the F01S100 cabinet.2 AC Single-phase Lightning Protection Bar This topic describes the power distribution scheme and the related technical specifications of the built-in AC single-phase lightning protection bar (optional) in the F01S100 cabinet.F01S100 Product Description 2 Product Structure Figure 2-3 Power distribution scheme of the F01S100 cabinet 2. 2..3. 2.3. Ltd.3. The AC PDU consists of the lightning arrester. maintenance socket. Table 2-4 lists the technical specifications of the maintenance socket.3.5 Remote power supply When configured with the DC-powered MA5610/MA5616.5kV (8/20 μs. the F01S100 cabinet uses the remote power supply as its DC power input. 2. Table 2-3 Specifications of the lightning arrester Item Rated voltage Maximum continuous running voltage (Uc) Rated discharge current (In) Maximum discharge current (Imax) Protection rating (Up) Value 220 VAC 380 VAC 20 kA (8/20 μs) 40 kA (8/20 μs) l l < 1.4 Battery Heater This topic describes the technical specifications of the battery heater used in the F01S100 cabinet. Issue 01 (2009-10-28) . 2-6 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.1 AC PDU This topic describes the power distribution scheme and the related technical specifications of the built-in AC PDU (optional) in the F01S100 cabinet. 2..3. Table 2-3 lists the technical specifications of the lightning arrester.3. batteries can be selected as the backup power supply. 2. 15 kA) Response time Dimensions Environment for usage ≤ 25 ns 100 mm x 65 mm x 72 mm l l Temperature: –40°C to +70°C Relative humidity: ≤ 95% Maintenance Socket The maintenance socket is connected to the maintenance terminal to facilitate the on-site maintenance. 2.2 Product Structure F01S100 Product Description When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616. Lightning Arrester The lightning arrester protects the 220 V single-phase power system against the surge voltage caused by the lightning.6 DC PDU This topic describes technical specifications of the built-in DC PDU in the F01S100 cabinet. and MCB.8kV (8/20 μs. 5 kA) < 1. 2. Type of socket hole Number of socket holes Issue 01 (2009-10-28) Versatile 3 bits 2-7 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. LED for polarity reversal Off: normal Yellow and on: An alarm is generated.3. LED for lightning protection Off: normal Red and on: The lightning protection fails.F01S100 Product Description 2 Product Structure Table 2-4 Technical specifications of the maintenance socket Item 220 VAC power supply Value 220 VAC/3 A MCB The MCB controls the external AC input. Table 2-5 Technical specifications of the AC single-phase lightning protection bar Item Rated working voltage Maximum continuous running voltage (Uc) Working frequency Rated working current Fuse current Fuse type Protection mode Rated through-current capacity (In) Maximum discharge current (Imax) Voltage protection rating (Up) LED for improper grounding Value 250 VAC 385 VAC 47 Hz to 63 Hz 8A 8A Slow-blow L-N. . Table 2-5 lists the technical specifications of the AC single-phase lightning protection bar used in the F01S100 cabinet. Ltd. L-PE.2 AC Single-phase Lightning Protection Bar This topic describes the power distribution scheme and the related technical specifications of the built-in AC single-phase lightning protection bar (optional) in the F01S100 cabinet. and N-PE 5 kA (8/20 μs) 15 kA (8/20 μs) 1500 V (8/20 us) Off: normal Red and on: An alarm is generated.. 3 Battery When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616.3.. Ltd. Issue 01 (2009-10-28) . Figure 2-4 shows appearance of battery. NOTE When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616. Table 2-6 Technical specifications of battery Item Rate working voltage (when configured with four batteries) 2-8 Value –48 VDC Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.2 Product Structure F01S100 Product Description Item Shell protection rating Flame retardant rating Response time Cable specifications Working temperature Storage temperature Relative humidity Dimensions (W x D x H) Value IP20 94-V0 Ta ≤ 25 ns With a diameter of 8 mm and a length of 2 m –40°C to +70°C –40°C to +85°C 5% to 95% 288 mm x 58 mm x 46 mm 2. Figure 2-4 Appearance of battery Table 2-6 lists the technical specifications of the batteries used in the F01S100 cabinet. a set (four batteries) of 12 Ah batteries can be selected as the backup power supply. batteries can be selected as the backup power supply. The AC-powered MA5610/MA5616 provides the interface for batteries. 5 Remote power supply When configured with the DC-powered MA5610/MA5616.F01S100 Product Description 2 Product Structure Item Rated capacity Floating charging voltage of the battery set Maximum charging current Voltage of a single battery Working temperature range Dimensions of a single battery (W x D x H) Weight of a single battery Value 12 Ah –54 VDC 3. Ltd.83 kg 2. 2-9 .3. Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. Table 2-8 lists the technical specifications of the remote power supply used in the F01S100 cabinet.6 A –12 VDC –15°C to +50°C 151 mm x 100 mm x 98 mm 3. Table 2-7 Technical specifications of the battery heater Item Rated voltage Voltage range Rated heating power Insulation resistance Value 220 VAC 150 VAC to 300 VAC 70 W The insulation resistance between the heater leading power cable and the heater shell must be greater than 10 megohms. NOTE Two battery heaters must be configured when the F01S100 cabinet is used in the area where the ambient temperature is below 0°C.4 Battery Heater This topic describes the technical specifications of the battery heater used in the F01S100 cabinet.3. 180 mm x 125 mm x 2 mm Working environment Dimensions (L x W x D) 2. Table 2-7 lists the technical specifications of the battery heater used in the F01S100 cabinet. the F01S100 cabinet uses the remote power supply as its DC power input. The heater can work reliably in the environment with relative humidity of 5% to 95%. 2. Issue 01 (2009-10-28) l 2-10 .4.2 Product Structure F01S100 Product Description Table 2-8 Technical specifications of the remote power supply Item Input rated voltage Input voltage range Output rated voltage Output voltage range Cooling method Working temperature range Storage temperature range Weight Dimensions (W x D x H) Value 340 VDC (+/-170 VDC) 285 VDC to 348 VDC –48 VDC –40 VDC to –57 VDC Forced air cooling -40℃ to +70℃ -40℃ to +80℃ 2.1 MDF This topic describes the specifications of the built-in MDF in the F01S100 cabinet. The exchange side terminal blocks are also used for tests and open circuits. 2. l The 16-pair exchange side terminal blocks are installed to be connected with the internal cables of the MDF and the jumper cables. The 10-pair cable side terminal blocks are installed to be connected with the external cables of the MDF and the jumper cables.3.4.5 mm 2.4. 2.2 ODF This topic provides the appearance of the built-in ODF in the F01S100 cabinet and describes the capacity specifications of the ODF.5 kg 445 mm x 230 mm x 44. Ltd. The ODF is used to connect the optical fiber and the optical communication device. The MCB controls the -48 VDC output of the remote power supply.4 Cable Distribution Device The F01S100 cabinet is configured with the built-in MDF and ODF. The MDF is used to connect the internal subscriber cable and the external subscriber cable. The DC PDU consists of the MCB. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. 2. The protective unit (optional) installed in the cable side terminal block provides the overvoltage protection and generates alarms.6 DC PDU This topic describes technical specifications of the built-in DC PDU in the F01S100 cabinet..1 MDF This topic describes the specifications of the built-in MDF in the F01S100 cabinet. Figure 2-5 Appearance of the MDF in the F01S100 cabinet Table 2-9 lists the specifications of the MDF. 2-11 . Ltd..F01S100 Product Description l 2 Product Structure The harness. provides connections between the service boards and the MDF. which consists of the connector. subscriber cable. Table 2-9 Specifications of the MDF in the F01S100 cabinet Item Type of the exchange side terminal block Value JPX658-STO-236XD (White) Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Figure 2-5 shows the appearance of the MDF in the F01S100 cabinet. and terminal block. The ODF is used to connect the optical fiber and the optical communication device. Adjust optical fibers.2 ODF This topic provides the appearance of the built-in ODF in the F01S100 cabinet and describes the capacity specifications of the ODF. Store optical fibers. Protect the cores of the peeled optical fibers. Ltd. 2-12 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.4. 2. Distribute optical fibers.. The ODF can perform the following functions: l l l l l Fasten and protect optical fibers. Issue 01 (2009-10-28) .2 Product Structure F01S100 Product Description Item Height of the exchange side terminal block Type of the cable side terminal block Value 12 mm l l l l JPX658-FA8-239XB (White) JPX658-FA8-239XH (Yellow) JPX658-BLK2-E10VB (White) JPX658-BLK2-E10VH (Yellow) JPX658-FA8-239XB (15 mm) JPX658-FA8-239XH (15 mm) JPX658-BLK2-E10VB (13 mm) JPX658-BLK2-E10VH (13 mm) JPX658-FA9-280J JPX658-FA10-97 JPX658-SPD2-G400T JPX658-VPS3-Y600-VDSL2 JPX658-VPS3-E270A-VDSL2 JPX658-VPS3-E270B-VDSL2 JPX658-VPS3-E320-VDSL2 Height of the cable side terminal block l l l l Type of the protective unit l l l Type of the SPL l l l l Height of the MDF 680 mm. which can be adjusted flexibly. Figure 2-6 shows the appearance of the ODF in the F01S100 cabinet. Ltd..5 Temperature Control Unit This topic provides the technical parameters of the built-in temperature control unit used in the F01S100 cabinet. Table 2-10 Specifications of the ODF ODF Type ODF (simple) Port Type FC/PC Capacity 6 adapters (default configuration: 2 adapters) 2. the highest environment temperature is 50°C). Table 2-11 describes the technical parameters of the heat dissipation fan.F01S100 Product Description 2 Product Structure Figure 2-6 Appearance of the ODF in the F01S100 cabinet Table 2-10 lists the specifications of the built-in ODF in the F01S100 cabinet. the cabinet can also be configured with a enhanced heat dissipation module to further improve the heat dissipation performance and to meet the requirement of the environment with a temperature higher than 45°C (When the solar radiation intensity is 1120 W/m2. 2-13 . Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. The F01S100 cabinet uses the heat exchanger mounted on the cabinet wall for heat dissipation. Besides. The enhanced heat dissipation consists of two heat dissipation fans. Figure 2-7 Monitoring scheme of the F01S100 cabinet 2-14 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.17 A 8. 2..97 CFM 92 mm x 92 mm x 25. 2.1 Monitoring Scheme The service chassis installed in the F01S100 cabinet monitors the environment and key components of the cabinet. Issue 01 (2009-10-28) .6.2 Product Structure F01S100 Product Description Table 2-11 Technical parameters of the heat dissipation fan Item Rated voltage Running voltage Input current Running power Rotating speed Wind volume Dimensions Value -48 VDC –28 VDC to –54 VDC 0.2 Sensor This topic provides the appearances of the built-in sensors in the F01S100 cabinet and provides the information about the functions of the sensors.6.4 mm 2.6 Monitoring System This topic describes the monitoring scheme and the built-in sensors of the F01S100 cabinet. Ltd.1 Monitoring Scheme The service chassis installed in the F01S100 cabinet monitors the environment and key components of the cabinet.6. Figure 2-7 shows the monitoring scheme of the F01S100 cabinet. 2.16 W 3700 rpm 81. Door status sensor The door status sensor uses the door status switch as the probe.F01S100 Product Description 2 Product Structure 2. The door status switch monitors the status of the cabinet door. Figure 2-8 shows the appearance of the door status sensor. The door status switch consists of two built-in parts. and outputs the dry contact output signals that do not have polarity. Figure 2-8 Appearance of the door status sensor Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd. The spring clips of the door status switch attract each other due to electromagnetic interaction.6. 2-15 .2 Sensor This topic provides the appearances of the built-in sensors in the F01S100 cabinet and provides the information about the functions of the sensors.. . F01S100 Product Description 3 System Configuration 3 About This Chapter System Configuration This topic provides the number of subscribers supported by the F01S100 cabinet.1 F01S100 cabinet Configured with the MA5610 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5610.2 F01S100 cabinet Configured with the MA5616 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5616. Ltd. Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. 3.. 3. 3-1 . Table 3-1 Number of subscribers supported by the F01S100 cabinet in different configurations Configuration One MA5610 (configured with four ASPB boards) One MA5610 (configured with three EIUA boards + one ASPB board) One MA5610 (configured with two EIUA boards + two ASPB boards) One MA5610 (configured with one EIUA board + three ASPB boards) Maximum Number of Subscribers 256 POTS 48 LAN + 64 POTS 32 LAN + 128 POTS 16 LAN + 192 POTS NOTE l l The ASPB board is the 64-channel narrowband service board that provides the POTS service. see the MA5610 Hardware Description. For details of the device. Table 3-1 lists the number of subscribers supported by the F01S100 cabinet in different configurations. 3. Issue 01 (2009-10-28) . Table 3-2 lists the number of subscribers supported by the F01S100 cabinet in different configurations.2 F01S100 cabinet Configured with the MA5616 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5616. In Table 3-1.3 System Configuration F01S100 Product Description 3. Table 3-2 Number of subscribers supported by the F01S100 cabinet in different configurations Configuration One MA5616 (configured with four ASPB boards) One MA5616 (configured with four ADLE boards) One MA5616 (configured with one ASPB board + three ADLE boards) 3-2 Maximum Number of Subscribers 256 POTS 128 ADSL2+ 64 POTS + 96 ADSL2+ Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd..1 F01S100 cabinet Configured with the MA5610 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5610. the number of subscribers is counted when the cabinet is configured with the device provided by Huawei. The EIUA board is the 16-channel Ethernet access board that provides the LAN service. The ADLE board is the 32-channel ADSL2+ service board with a built-in splitter. 3-3 . The VDTH board is the 24-channel VDSL2 service board without a built-in splitter. Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. In Table 3-2.F01S100 Product Description 3 System Configuration Configuration One MA5616 (configured with four VDSE/VDSH/ VDTH boards) One MA5616 (configured with two ASPB boards + two VDSE/VDSH boards) Maximum Number of Subscribers 96 VDSL2 128 POTS + 48 VDSL2 NOTE l l l l l l The ASPB board is the 64-channel narrowband service board that provides the POTS service. the number of subscribers is counted when the cabinet is configured with the device provided by Huawei. It provides the VDSL2 service. For details of the device.. The VDSE board is the 24-channel VDSL2 service board with a built-in splitter. It provides the VDSL2 service. The VDGE board is the 16-channel VDSL2 service board with a built-in splitter. It provides the VDSL2 service. Ltd. It provides the VDSL2 service. The VDSH board is the 24-channel VDSL2 service board without a built-in splitter. see the MA5616 Hardware Description. It provides the ADSL2+ services. . Dimensions (W x D x H) 720 mm x 250 mm x 830 mm 720 mm x 250 mm x 1030 mm F01S100 cabinet (without battery compartment) Table 4-2 lists the weight of the F01S100 cabinet. with battery compartment. Value 187.F01S100 Product Description 4 System Parameters 4 Table 4-1 Dimensions of the F01S100 cabinet Item F01S100 cabinet (with battery compartment) System Parameters This topic provides the parameters of the F01S100 cabinet.6 W 250 W 4-1 . fully-loaded) Weight 57 kg 84 kg Table 4-3 lists the power of the F01S100 cabinet. Table 4-2 Weight of the F01S100 cabinet Item F01S100 cabinet (without battery compartment. Ltd. fullyloaded) F01S100 cabinet (fully-loaded.. Table 4-3 Power of the F01S100 cabinet Item Maximum power of the F01S100 cabinet (configured with the AC-powered MA5610/MA5616) Maximum power of the F01S100 cabinet (configured with the DC-powered MA5610/MA5616) Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Table 4-1 lists the dimensions of the F01S100 cabinet. . and running of the F01S100 cabinet.F01S100 Product Description 5 Environmental Specifications 5 Environment Storage Environmental Specifications This topic describes the environmental specifications for the storage.. Ltd. and running of the cabinet. Table 5-1 Environment specifications of the F01S100 cabinet Item Solar radiation intensity Temperature Relative humidity Air pressure Transportation Solar radiation intensity Temperature Relative humidity (without much variation in temperature) Relative humidity (with much variation in temperature: air/air) Air pressure Running Solar radiation intensity Temperature (when the F01S100 cabinet is configured with one MA5610/MA5616. transportation. with the enhanced heat dissipation module and ) Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. transportation. Table 5-1 lists the environment specifications for the storage. without the enhanced heat dissipation module and ) Temperature (when the F01S100 cabinet is configured with one MA5610/MA5616. Value ≤1120 W/m2 –45°C to +45°C 8% to 100% 70 kPa to 106 kPa ≤1120 W/m2 –40°C to +70°C 95% (+45°C) 95% (-40°C to +30°C) ≥ 70 kPa ≤1120 W/m2 –33°C to +45°C –33°C to +50°C 5-1 . 5 Environmental Specifications F01S100 Product Description Environment Item Relative humidity Air pressure Value 8% to 100% 70 kPa to 106 kPa 5-2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd.. Issue 01 (2009-10-28) . . Part 1-4: Classification of environmental conditions.F01S100 Product Description 6 Standards Compliance 6 Item Running environment Standards Compliance This topic provides the standards that the F01S100 cabinet complies with in terms of the environment. Ltd. Transportation ETSI EN 300 019–1–1 IEC 60950–1/ IEC 60065: Safety of information of technology equipment IEC 60950-22: Degrees of protection provided by enclosures (IP code) ETSI EN 300 753 1997-10 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. power system and lightning proof. Stationary use at nonweather protected locations ETSI 300 019 – 1 . Part 1-2: Classification of environmental conditions.3E Necessary Protection IP55 Noise Issue 01 (2009-10-28) Class 4. Class Class 4.2 Public transportation Storage environment Safety Class 1.1 Rural 6-1 .1E Nonweatherprotected locationsextended Transportation environment Class 2. Table 6-1 Standards compliance of the F01S100 cabinet Standards Compliance ETSI EN 300 019-1-4: Environmental conditions and environmental test for telecommunications equipment. structure. Table 6-1 provides the standards compliance of the F01S100 cabinet.2: Environmental conditions and environmental test for telecommunications equipment. .45: Performance requirement for surge protective device connected to low-voltage distribution systems of telecommunication stations/ sites ETSI EN 300 253: Earthing and bonding of telecommunication equipment in telecommunication centers Grounding Necessary 6-2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Ltd. Issue 01 (2009-10-28) .45: Resistibility of telecommunication equipment installed in the access and trunk networks to overvoltage and overcurrent YD 694-2004 - Necessary Lightning proof ITU-T K.3): Cabinets and Pitches of racks structure K.6 Standards Compliance F01S100 Product Description Structure MDF IEC 297_1 (2. 7-1 . Ltd.F01S100 Product Description 7 Acronyms and Abbreviations 7 A AC ADSL ADSL2+ D DC Acronyms and Abbreviations Alternating current Asymmetrical digital subscriber line Asymmetrical digital subscriber line 2 plus Direct current E EMC EMU EN ETS ETSI Electro magnetic compatibility Environment monitoring unit End node European Telecommunication Standard European Telecommunications Standards Institute F FE Fast Ethernet G GE Gigabit Ethernet I IDC Issue 01 (2009-10-28) Internet data center Huawei Proprietary and Confidential Copyright © Huawei Technologies Co.. Ltd.7 Acronyms and Abbreviations F01S100 Product Description IEC IEEE IP ITU-T International Electrotechnical Commission Institute of Electrical and Electronics Engineers Internet protocol International Telecommunication Union ..Telecommunication Standardization Sector L LAN Local area network M MDF Main distribution frame O ODF Optical distribution frame P POTS PSTN Plain old telephone service Public switched telephone network V VDSL VDSL2 Very high speed digital subscriber line Very high speed digital subscriber line 2 7-2 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co. Issue 01 (2009-10-28) .
Copyright © 2024 DOKUMEN.SITE Inc.