HiAN+HiAS Air Circuit Breaker_m

March 30, 2018 | Author: Ali Mehmood Malhi | Category: Switch, Mains Electricity, Relay, Capacitor, Components


Comments



Description

Air Circuit Breaker Designed for both industrial and marine application, HYUNDAI Air Circuit Breakers have innovative structure, Various protections, and reliable performance. HiAN & HiAH type HiAN06-20 ⇢ 70kA up to 2000A HiAN25-32 ⇢ 85kA 2500A, 3200A HiAN40 ⇢ 100kA 4000A HiAN50-63 ⇢ 120kA 5000A, 6300A HiAH32 ⇢ 130kA 3200A ※ Breaking capacity: Icu at AC500V We build a better future! CONTENTS 04 - Qualified Standard & Approval 05 - Features 08 - Ratings 11 - Specification Overview 12 - Mounting HiAS type HiAS06-16 ⇢ 50kA up to 1600A HiAS20-32 ⇢ 65kA up to 3200A ※ Breaking capacity: Icu at AC500V 14 - Charging Operations 15 - Electrical Trip Devices 16 - ACB Protection Relays 25 - Characteristic Curves 26 - APR Wiring Diagrams 28 - Accessories 34 - Derating Tables 35 - Internal Resistance 36 - Circuit Diagrams 40 - Dimensions 60 - Order Information 67 - Operation Environment 9001 ▶ KERI/KOREA | 04 | ▶ CE/EU Korea Electro Technology Reserch Institute .S. 14001.13 American National Standard Institute ▶ VDE 0660 Verband Deutscher Elektrotechniker ▶ GOST R 50030.1-2000 Government Standard of Russia Approval ▶ ISO 18001.A. Lloyd’s Register of Shipping ▶ ABS/U. American Bureau of Shipping ▶ BV/FRANCE Bureau Veritas ▶ NK/JAPAN Nippon Kaiji Kyokai .. Community European/TUV Rheinland ▶ GOST-R/RUSSIA Government Standard of Russia ▶ CCC/CHINA China Compulsory Certification ▶ KR/KOREA Korean Register of Shipping ▶ GL/GERMANY Germanischer Lloyd ▶ LR/U.2-99 9 Government Standard of Russia ▶ GOST R 50030.K.Air Circuit Breaker Qualified Standard & Approval Standard ▶ IEC 60947-2 International Electrotechnical Commission ▶ EN 60947-2 European Standard ▶ AS 3972-2 Australian Standard ▶ NEMA PUB NO.SG3 National Electrical Manufactures Association ▶ ANSI C37. Breakers can also be replaced according to system specification changes. D: Depth (including terminal part) H D W Multi-function ACB protection relay (APR) ■ By mounting of high-reliable multi function protection relay. Icw 65kA at AC500V Customized design ■ Minimized dimension difference of ACBs make easy to design switchboards. line and load side reverse connection and convienient replacement of APR. ■ Easy insertion to cradle. ACBs can conduct perfect performance. (Unit: mm) Draw-out type H W D HiAN06-16 490 320 461. This front mounted design enables easy wiring.2 HiAN40 478 480 481 HiAN50-63 478 984 481 HiAH32 478 480 481 HiAS06-16 459 320 461. ■ All circuits and manual operation parts are in front side.2 ※ H: Height. W: Width. HiAN06-20 ⇢ 70kA HiAN25-32 ⇢ 85kA HiAN40 ⇢ 100kA HiAN50-63 ⇢ 120kA HiAH32 ⇢ 130kA •HiAN type: up to Icu 120kA. ■ All type ACBs have same panel cut-out size. Icw 100kA at AC500V •HiAH type: Icu 130kA. HiAH & HiAS Type Features High breaking capacity Hyundai Air Circuit Breakers realize high breaking capacity and short-time withstand current with advanced technologies.2 HiAN20-32 490 410 461. | 05 | . 7 types of APR are available according to required functions. trip device and motor also offer greater satisfaction to customers. operation and inspection.HiAN.2 HiAS20-32 459 410 461. so it is also easy to standardize the switchboard design. Air Circuit Breaker Features Front view of ACB Lifting lug option Control circuit Fixing block option Front cover option Draw-in/out handle Cycle counter option Charging handle Charged/Discharged indicator Close/Open indicator Protection relay Close button Open button Key lock device option Name plate Cradle Position indicator and draw-in/out hole [ HiAN & HiAH type ] Lifting lug option Control circuit Fixing block option Front cover option Cycle counter Charged/Discharged indicator Close/open indicator Draw-in/out handle Close button Charging handle Protection relay Open button Name plate Key lock device option Position indicator and draw-in/out hole Cradle [ HiAS type ] | 06 | . accessories are easy to install and maintain. | 07 | . convenience and performance of ACBs. •HiAH type HiAH type ACB has the highest breaking capacity in the world. Wide current from 630A to 3200A can be realized in the same frame.HiAN. ■ Internal surge protection device suppresses the surge of ACB itself and protects against mis-operation of loads. •Extensional auxiliary switch (1a1b) •Key lock device (lock in open) •Cycle counter •Door flange •Lifting lugs •Button lock cover •Neutral CT •Mechanical interlock device •Spring charge switch •Non-flammable cable •Safety shutter •Fixing blocks •Vertical type bus-bar •Short circuit ‘b’ contact •Position switch •Wrong inserting pervention device •Arc shield •100% size neutral pole •Test jumper •APR checker Introduction of HiAH & HiAS type Both HiAH & HiAS type ACB are based on the HiAN type. ■ The neutral pole contact closes earlier than the main cirucit contacts and opens later. This early-make late-break N pole contact effectively prevents the occurrence of the abnormal voltages between the phase lines and the neutral line. ■ Various accessories also contribute to safety features. •HiAS type HiAS type ACB is best suited for simple application with lower breaking capacity and compact size compared to HiAN type. HiAH & HiAS Type Safety provision ■ The fully molded body increases the safety in any application. they can cover all applications together with HiAN type. By adopting different technology. especially for marine use or in power plants. Various accessories and options ■ Varrious ■ All accessories are available for better safety. thus ensuring safety. 000 1.300 3.000 1.200 4.000 2.250 1.200 Rated neutral phase current (A) 630 800 1. operating Closing time (sec) max.000 800 [ICT] (A) 630 2.04 3pole. VDE Icu=100% lcs BS AS AC415V below 154 154 154 154 154 187 187 187 220 291 291 286 without Inst.000 6. fixed type ※ Value is open air at 40℃ | 0.600 2. AC600V 50 50 50 50 50 65 65 65 85 100 100 65 (MCR) AC500V below 70 70 70 70 70 70 85 85 100 120 120 65 AC690V 105 105 105 105 105 143 143 143 187 220 220 220 AC500V 154 154 154 154 154 154 187 187 220 291 291 286 Rated making capacity (kA peak) [lcm] IEC with Inst.000 5.000 5.250 3.03 Total breaking time (sec) Closing Charging time (sec) max.600 2.600 4.000 Rated operation voltage (Ue) (V) AC690 Rated breaking capacity (kA sym) [lcu] IEC with Inst.300 3.000 1.500 3.250 1.000 630 ACB protection relay 320 320 320 320 320 1.600 630 630 630 630 800 800 800 800 1.000 1.000 2.200 4.000 3.500 1. draw-out type 76 76 76 85 85 100 110 120 135 230 250 130 Dimensions (mm) Height (3pole.2 480 984 481 480 .600 2.200 5. draw-out type) Width Depth 08 0.000 2.500 2. time Weight (kg) | 0.300 1. AC600V 105 105 105 105 105 143 143 143 187 220 220 143 (MCR) AC500V below 154 154 154 154 154 154 187 187 220 291 291 143 8 Rated impulse withstand voltage (Uimp) [kV] Rated short-time withstand current [lcw] (rms) 1sec Rated latching current (kA) 65 65 65 65 65 70 85 85 75 100 100 65 65 65 65 65 65 70 85 85 75 100 100 65 0.000 1.250 2.000 6.000 2.600 1.06 43 43 43 49 49 60 63 65 - - - - 3pole.000 2.500 3.500 3.000 2.250 1. draw-out type 65 65 65 72 72 87 92 96 115 210 230 110 4pole.000 4.600 1.000 1.500 3.200 1.000 6.200 4.200 3. fixed type 51 51 51 58 58 69 76 83 - - - - 4pole. VDE Icu=100% lcs BS AS AC690V 50 50 50 50 50 65 65 65 85 100 100 100 AC500V 70 70 70 70 70 70 85 85 100 120 120 130 AC415V below 70 70 70 70 70 85 85 85 100 120 120 130 without Inst.200 Rated insulation voltage (Ui) (V) AC1.04 10 490 320 478 410 461.Air Circuit Breaker Ratings General feeder application / HiAN & HiAH type Model HiAN06 HiAN08 HiAN10 HiAN12 HiAN16 HiAN20 HiAN25 HiAN32 HiAN40 HiAN50 HiAN63 HiAH32 Rated current (A) 630 800 1.000 1.000 5. 4 Number of poles B Utilization category Rated primary current of 160 160 160 160 160 1.000 1. 500 2.200 Number of poles 3.000 1.2 88.250 2. AC600V 88. VDE Icu=100% lcs BS AS AC690V 42 42 42 42 42 50 50 50 AC500V 50 50 50 50 50 65 65 65 AC415V below 50 50 50 50 50 65 65 65 without Inst. AC600V 42 42 42 42 42 50 50 50 (MCR) AC500V below 50 50 50 50 50 65 65 65 AC690V 88.000 1.2 105 105 105 AC500V 110 110 110 110 110 143 143 143 Rated making capacity (kA peak) [lcm] IEC with Inst.2 88.250 1. fixed type 43 43 43 49 49 60 63 65 3pole.HiAN.2 88.500 3.000 1. VDE Icu=100 % lcs BS AS AC415V below 110 110 110 110 110 143 143 143 without Inst.000 Rated operation voltage (Ue) (V) AC690 Rated breaking capacity (kA sym) [lcu] IEC with Inst.04 3pole.000 2.2 105 105 105 (MCR) AC500V below 110 110 110 110 110 143 143 143 8 Rated impulse withstand voltage (Uimp) [kV] Rated short-time withstand 1sec current [lcw] (rms) Rated latching current (kA) 42 42 42 42 42 50 50 50 42 42 42 42 42 50 50 50 0. operating Closing time (sec) max. draw-out type) Width Depth 459 320 410 461. draw-out type 76 76 76 85 85 100 110 120 Dimensions (mm) Height (3pole. time Weight (kg) 10 0.000 2.000 800 800 800 800 1.000 1.600 1.000 1.2 ※ Value is open air at 40℃ | 09 | .600 2.000 1.2 88.250 1.03 Total breaking time (sec) Closing Charging time (sec) max.2 88.200 Rated neutral phase current (A) 630 800 1.600 Rated insulation voltage (Ui) (V) AC1.000 ACB protection relay 320 320 320 320 320 1.2 88.500 3.500 3.600 2.000 2.600 1. fixed type 51 51 51 58 58 69 76 83 4pole.2 88.250 1.2 88.600 [ICT] (A) 630 630 630 630 630 2. draw-out type 65 65 65 72 72 87 92 96 4pole. HiAH & HiAS Type General feeder application / HiAS type Model HiAS06 HiAS08 HiAS10 HiAS12 HiAS16 HiAS20 HiAS25 HiAS32 Rated current (A) 630 800 1.000 1. 4 Utilization category B Rated primary current of 160 160 160 160 160 1.200 1.000 2. 600 800≤Io≤1.000≤Io≤2. draw-out type) 100 65 72 72 0.03 Height (3pole.250≤Io≤2.000≤Io≤4.000 500≤Io≤1. Dimensions (mm) 65 0.250 800≺Io≦1.250 1.250≺Io≦2.000 Rated operation voltage (Ue) (V) AC690 Rated breaking capacity (kA.600 800≤Io≤1. sym) [Icu] / Rated making capacity (kA peak) [Icm] KR AC480V 70/154 70/154 70/154 70/154 85/187 85/187 100/220 120/291 120/291 130/266 LR AC500V 70/154 70/154 70/154 70/154 85/187 85/187 100/220 120/291 120/291 130/266 AC480V 70/154 70/154 70/154 70/154 85/187 85/187 100/220 120/291 120/291 130/266 AC480V 70/154 - 70/154 70/154 85/187 85/187 100/220 120/291 120/291 130/266 BV AC480V 70/154 70/154 70/154 70/154 85/187 85/187 100/220 120/291 120/291 130/266 NK AC480V 70/154 70/154 70/154 70/154 85/187 85/187 100/220 120/291 120/291 130/266 65 65 65 70 85 85 75 100 65 65 65 70 85 85 75 100 ABS GL Icu=100% Ics Rated short-time withstand current [lcw] (rms) 1sec Rated latching current (kA) Total breaking time (sec) Closing operating time 0.000 2.250 1.500≤Io≤5.000≤Io≤4.500≤Io≤5.000 400≺Io≦800 [Io] (A) 160≤Io≤320 160≤Io≤320 160≤Io≤320 1000≤Io≤2.000≺Io≦2.600 1.600≤Io≤3.500 3.000 1.600≤Io≤4. Weight (kg) (3pole.200 630≺Io≦1.200 Number of poles 3 Utilization category B Base current of 40≤Io≤80 ACB protection relay 80≤Io≤160 80≤Io≤160 80≤Io≤160 800≤Io≤1.200 4.000 1.000 2.000 2.500 800≤Io≤1.000 6.Air Circuit Breaker Ratings Generator application for marine purpose / HiAN & HiAH type Medel Rated current (A) HiAN08 HiAN12 HiAN16 HiAN20 HiAN25 HiAN32 HiAN40 HiAN50 HiAN63 HiAH32 800 1.600 2.000≤Io≤2.2 210 480 984 481 480 .000 320≺Io≦630 320≤Io≤630 320≤Io≤630 320≤Io≤630 1.000 5.000 2.04 Charging time (sec) max.04 Closing time (sec) max.250 630≤Io≤1.000 1.300500≺Io≦1.000 630≤Io≤1.200 Rated insulation voltage (Ui) (V) AC1.600 2.000 1.600≺Io≦3.000 3.500 400≤Io≤800 400≤Io≤800 400≤Io≤800 1.250≤Io≤2.200≤Io≤6.300 3. draw-out type) Width Depth | 10 | 100 65 230 110 10 0.600 500≤Io≤1.000 500≤Io≤1.500 1.06 87 92 96 115 490 320 478 410 461.000 500≤Io≤1.000 40≤Io≤80 40≤Io≤80 500≤Io≤1. isolated: 1C Mechanical interlock device / Hori.. for HiAN06-32 Safety shutter Test jumper Key lock device / lock in open Fixing blocks APR checker Cycle counter Vertical type bus-bar for draw-out type Door flange Short circuit ‘b’ contact Lifting lugs Position switch / conn. 2ST Position switch / inserted: 1C...: 2C Neutral CT for 3pole Position switch / test: 2C Mechanical interlock device / Hori.HiAN. test: 1C Button lock cover Position switch / conn.. 3ST Position switch / inserted: 1C Mechanical interlock device / Vert.: 1C. 3ST Wrong inserting pervention device Spring charge switch Arc shield Non-flammable cable 100% size neutral pole for HiN50-63 | 11 | . 2ST Position switch / isolated: 1C Mechanical interlock device / Vert. HiAH & HiAS Type Specification Overview Common use Draw-out type only Portable test equipment Extensional auxiliary switch / 1a1b. ISOLATED position The main circuit is disconnected. This position permits operation tests without the opening of the switchboard panel door. . ISOLATED. REMOVED position The breaker body is competely removed from draw-out cradle. TEST. The breaker body is installed in draw-out cradle that is fixed in the switchboard. TEST. | 12 | TEST position The main circuit is isolated and the control circuit is connected. and ISOLATED positions (“shut-in three positions”) [ HiAN & HiAH type ] CONNECTED position Both the main and control circuit are connected for normal service.Air Circuit Breaker Mounting Fixed type Fixed type ACB has no draw-out cradle and is designed to be directly mounted on the switchboard. The switchboard panel door can be closed. Draw-out type Draw-out type ACB consists of a breaker body and a draw-out cradle. and can be in four positions: CONNECTED. The switchboard panel door can be kept closed at the CONNECTED. and REMOVED. The switchboard panel door can be closed. HiAH & HiAS Type [ HiAS type ] CONNECTED position Both the main and control circuits are connected for normal service. Control circuit terminals Control circuit terminals are front located to allow easy wiring and access.HiAN. horizontal terminals are given as standard. 16 ex) HiAN12. 16 HiAS12. TEST position The main circuit is isolated and the control circuit is connected. REMOVED position The breaker body is competely removed from draw-out cradle. 16 | 13 | . Unless otherwise specified by the user. ex) HiAN12. 16 HiAS12. (Unit: mm) Main circuit terminals Horizontal terminals Vertical terminals Two types of main circuit terminal arrangements are available: vertical terminals and horizontal terminals. ISOLATED position The main circuits are disconnected. Different types of terminal arrangements can be specified for the line and load sides. This position permits operation tests without the opening of the switchboard panel door. the ON signal is ignored.5 5 1.5 DC24 20 -27 5.5 -123 15 7.0 10 1.2 5 1. ON/OFF operation of the ACB can be performed remotely. When the closing springs are released to close the ACB.0 5 3.0 DC110 Anti-pumping function Even if the ON switch is kept on.0 1. and then turn on the ON switch.0 10 1. Rating of ACB charging motor Applied model HiAN06-32 HiAH32 HiAS06-32 HiAN40-63 Rated voltage (V) Operation voltage (V) Inrush current (at peak) (A) Steady-state current (rms) (A) Charging time (s) Closing current (at peak) (A) AC220 187 -246 2. If ON and OFF signals are simultaneously given of the ACB.0 5 8.0 0.5 AC110 93. ACB closing operation is performed only once.5 5 3.0 DC125 106 -140 5. A manual charging mechanism is also fitted to facilitate inspection or maintenance work.5 -123 2.5 DC220 170 -246 6. | 14 | Anti-pumping circuit .0 10 1.0 1.0 AC220 187 -246 8. turn off the ON switch to charge the closing springs.5 5 1.5 0.0 1.5 10 1.6 85 -126 3.5 0.0 AC110 93. they are automatically charged again by the motor for the next ON operation. ■ Closing the ACB Turning on “remote” ON switch enables the ACB to be remotely closed.Air Circuit Breaker Charging Operations Manual charging type The closing springs are charged by the spring charging handle.2 DC24 20 -27 3.7 5 3.5 DC125 106 -140 3. The control circuits provide optimum control to the spring charging and ACB ON/OFF operation.0 5 3.5 1. ■ Opening the ACB For opening the ACB remotely.5 1. To close the ACB again.0 1. Motor charging type The closing springs are charged by a motor. ■ Charging the closing springs A motor is used to charge the closing springs.2 DC220 170 -246 2. ON/OFF operation of the ACB is performed by CLOSE/OPEN buttons.5 DC110 85 -126 12 3.0 4. specify the shunt trip or the undervoltage trip. pick-up voltage. Two types of UVT are available: Rating of shunt Applied model undervoltage trip consists of a tripping coil and a trip 252-528 228-462 108-275 60-165 60-165 90-276 54-150 29-57 14-28 252-528 228-462 108-275 60-165 60-165 90-276 54-150 29-57 14-28 252-528 228-462 108-275 60-165 60-165 90-276 54-150 29-57 14-28 1. ■A time-delay trip.0 (220V) 1.2 (110V) 4.8 (48V) 8.15 (110V) 0. such as over-current relays When the voltage is restored to a value higher then the or reverse power relays.0 (24V) 27 27 27 27 27 30 30 30 29 27 27 27 27 27 28 30 29 28 27 27 27 27 27 28 30 29 28 immediately.0 (220V) 1.8 (24V) 1.6 (220V) 3.1 (200V) 0. ■An instantaneous trip.9 (48V) 8. HiAH & HiAS Type Electrical Trip Devices Shunt trip (SHT) Under voltage trip (UVT) The shunt trip is used to electrically open the breaker from The undervoltage trip (UVT) automatically opens the Air a remote place(s).2 (450V) 1.7 (125V) 1.1 (110V) 3. The UVT device is also available for DC applications in conjunction with a current limiting resister (installed externally to the breaker) Rating of UVT Type Rated voltage (V) Excitation coil Pick-up voltage Drop-out voltage current (A) Operating voltage 480-500 430-470 85% of 35-70% of AC 360-400 rated voltage rated voltage 200-240 100-120 480-500 430-470 85% of 35-70% of AC 360-400 Instanrated voltage rated voltage 200-240 taneous type 100-120 200-220 85% of 35-70% of DC 100-125 rated voltage rated voltage Timedelay type 0.15 (380V) 0.3 (220V) 3. and may be used to open the Frequency 50/60Hz breaker by an external protective device.HiAN.5 (110V) 1. the Air Circuit Breaker can be closed.8 (24V) 0.3 (380V) 1.15 (220V) 0.2 (110V) 3.15 (450V) 0.15 (480V) 0.3 (450V) 1.5 (48V) 3.15 (380V) 0. its circuit voltage drops below a predetermined value. which trip the Air Circuit Breaker Current Operation Excitation Rated curent passage voltage (V) voltage (V) (at peak) (A) time (ms) AC HiAN06-16 HiAS06-16 DC AC HiAN20-32 HiAH32 HiAS20-32 DC AC HiAN40 HiAN50 HiAN60 DC 421-480 380-420 180-250 100-150 100-150 150-230 90-125 48 24 421-480 380-420 180-250 100-150 100-150 150-230 90-125 48 24 421-480 380-420 180-250 100-150 100-150 150-230 90-125 48 24 control device. The Both shunt trip and undervoltage trip may be fitted in a single breaker.4 (380V) 1.5sec Applied standard DC290V DC2A IEC 60694/KSC4611 | 15 | . Circuit Breaker when control power voltage drops below a The shunt trip may be used to open the breaker by means predetermined value.15 (220V) 0.5 (220V) 3.6 (450V) 0.15 (110V) 0.5 (110V) 2.15 (480V) 0. thus providing coordination with the short timedelay characteristic. Ordinary charging voltage DC145V A combination of capacitor trip and shunt trip work as a Rated current normal AC-rated shunt trip. Delay time 1. to Order code HVFS-T7 HVFS-T9 ensure normal operation within 30 seconds after the control Rated input voltage AC110V AC220V power (AC) is out or in a low voltage condition.4 (220V) 3.5 (125V) 1.7 (380V) 1.1 (100V) Condensor trip device (CTD) The capacitor trip is used in conjunction with a shunt trip. of external protective devices.15 (450V) 0. which operates with a time-delay of 500ms.7 (125V) 1.2 (110V) 4. CPU is also monitored (system alarm function). please refer to page 18. contacts make the signal through LED or LCD until the APR is reset. Indication function IU Integrated Instantaneous Indication Contact : 1a contact makes the signal for 80ms after a protection function operates. NP | 16 | Neutral Pole Protection : Neutral pole can be protected from damage by large current. AS and AI tunction can be tested by APR itself or APR checker. IUt Integrated Continuous Indication Contact : When any protection function operates. AS. Protection function AL Adjustable Long Time Delay Trip AS Adjustable Short Time Delay Trip AI Adjustable Instantaneous Trip AP Adjustable Pre-trip Alarm : When the current reaches to the setting value. AI AP AG MCR APR-1L-GL 23 ● APR-1L-GS 24 ● ● ● ● APR-1L-GM 27 ● ● ● ● APR-2L-GS 25 ● ● ● ● APR-1D-GM 26 ● ● ● APR-1S-AL 28 ● APR-1S-AS 29 ● Indication function NP ● IU IUt CP/I Fault Event LCD LED 1) memory display Filed test 2) Individual control AMS4) power 3) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ※ 1) LED makes signal when protection function operates. and MCR function can work by switching the INST/MCR knob.Insulation level from earth to terminal is 1500V. . and 2 types for generator protection.Air Circuit Breaker ACB Protection Relays APR is high-realiable multi function protection relay of Hyundai Air Circuit Breaker. it trips the ACB when the current exceeds pick-up current (IP) only during the closing operation. 2) AL.Signal for AP is automatically off when the current drops below the pick-up current (IP). pre-trip alarm operates. Application General feeder Generator Protection function Type Order code AL. . contacts make the signal through LED or LCD until the APR is reset. 7 Types of APR are available: 5 types for general feeder protection. 3) Individual control power for APR is required. AG Adjustable Ground Fault Trip MCR Making Current Release : MCR is one kind of instantaneous trip device. ※ . AI function is default. so that customers can select the proper one in consideration of the system and load charasteristics. After the ACB is completely closed. CP/I Individual Continuous Indication Contact : When each protection function operates. MCR function dose not work. Each APR has different protection and indication functions. ● . 4) APR monitoring system. 630. HiAS08 HiAN10. 630. 2500 1000. Pre-trip alarm (AP) and ground fault trip (AG). 0. 1.2A. 630 80. HiAS10 HiAN12. 160. 1600. 320. 630. 800. 1600 1000. instantaneous trip (AI). . HiAS06 HiAN08. 1600. 630. 320.The rated secondary current of APR is 0. •Keep the condition (ICT)≥(ILOAD). ■ Step2 ■ Step2 •Determine the base current •Determine the rated primary current (ICT) of APR based on (lo) for the current setting of trip functions. HiAS25 HiAN32. HiAS20 HiAN25. HiAS20 HiAN25. 1250.HiAN. 5000 4000. | 17 | . 160. ■ Step3 ■ Step3 •Determine the base current (lo) for the current setting of trip functions. 2000 1000. 800. 3200 HiAN08. 800. 2000.63. HiAS12 HiAN16. HiAS25 HiAN32. 320. •Determine the characteristic of long time delay trip (AL). HiAS12 HiAN16. 1250 80. 320. 1250. 160. 800. 2000. HiAS32 HiAN40 HiAN50 HiAN63 HiAH32 Base current (lo) of APR (A) 40 ≤ [lo] ≤ 800 40 ≤ [lo] ≤ 1250 40 ≤ [lo] ≤ 1600 500 ≤ [lo] ≤ 2000 500 ≤ [lo] ≤ 2500 500 ≤ [lo] ≤ 3200 2000 ≤ [lo] ≤ 4000 2000 ≤ [lo] ≤ 5000 2000 ≤ [lo] ≤ 6300 320 ≤ [lo] ≤ 3200 ※ . Model Rated primary current (lCT) of APR (A) Model HiAN06. through the breaker. •(lo)=(ICT)×0. 6300 630.0 ■ Step4 •Determine the characteristic of long time delay trip (AL). 1600.2A. 0. short time-delay trip (AS). 5000.5. 1000. Pre-trip alarm (AP) and ground fault trip (AG). 1000. HiAH & HiAS Type General feeder protection Generator protection ■ Step1 ■ Step1 •Determine the rated current of •Determine the rated current load (ILOAD) that will pass of generator (lGEN). HiAS16 HiAN20. HiAS16 HiAN20. 160. 1000 80. ※ The rated secondary current of APR is 0. Note: The ground fault trip function is not available when the rated primary current (ICT) of the APR is 160A. below table. 2500. 160. 2500. 2000. 1000. HiAS08 HiAN12.8. short time delay trip (AS). 320. 800 80. 3200 4000 4000. HiAS32 HiAN40 HiAN50 HiAN63 HiAH32 80. 1600.HiAS types are not applicable for marine purpose. instantaneous trip (AI). AS and AI functions are set to NON position. AI. “Fail- charasteristics. AS. | 18 | . Through the interface unit or coordination with SCADA (supervisory control and data acquisition) system. Holding register Remark 00 Pass Word Read 0×FFFF 01 LTD Pickup Read (%) 02 LTD Time ×10 (mSec) Parity: None 03 STD Pickup Read (%) Stop bit: 1 bit 04 STD Time ×10 (mSec) 05 INST Pickup Read (%) ■ Protocol 06 PreAlarm Pickup Read (%) .Air Circuit Breaker ACB Protection Relays APR monitoring system (AMS) APR-1D-GM type APR has the RS-485 communication port. ■ Holding register (16 bit register) ■ Method . APR monitoring system controls ACB and monitors system as well as operates.Modbus Protocol (RTU) 07 PreAlarm Time ×10 (mSec) .CRC16 08 GFT Pickup Read (%) 09 GFT Time ×10 (mSec) 10 OCR On/Off bit Masking 11 OCGR On/Off bit Masking 12 APR Mode 13 CT Ratio Frame Current 14 PT Ratio System Voltage 15 Hz 50/60Hz Baud Rate: 9600 bps Data bit: 8 bit AMS Server TCP/IP (Ethernet) HICM360/860 RS-485 APR 1 APR 2 APR 3 APR 4 APR 5 APR N Precise protection coordination Non position for pick-up current Fail-safe function for system security The pick-up current setting dials of protection functions In the event of a fault current exceeding ten times the (AL.Nonsyn.RS-485 Address . Safe” function will interrupt the fault current in a time equal to the short-time delay setting (T2). AG) can be set to NON position so that precise base current (lo) (five times for generator protection) while protection coordination is possible according to load the AL. HiAN.5% 80-160-240-320-400-480-560 msec ±15% Time (TG) IU (Integrated instantaneous contact) LED 1a. for general feeder Characteristic T1 : GFT time T2 : STD time TG : GFT time I1 : LTD current I2 : STD current I3 : INST current IG : GFT current APR-1L-GL Type Base current (l0) AL (LTD) Current (l1) Time (T1) Protection function AS (STD) AI (INST) AG (GFT) Indication function Current (l2) Time (T2) Tolerance ICT×(0.25-0. I t is possible by ON/OFF 2 Current (l3) I0×(Non-4-6-8-10-12-14-16) ±20% Current (lG) ICT×(Non-0.35-0.0) I0×(Non-0.5-3-4-6-8-10) ±15% 80-160-240-320-400-480-560 msec.1-0.9-0. AI. 80ms ON for AL.5-1.05 Non Trip.63-0.15-0.25-2.8-0.05-1.85-0.3-0.5-5-10-15-20-25-30 sec at I1×600% ±15% I0×(Non-2-2.2 Trip 0.8-1.95-1.4) ±7. HiAH & HiAS Type APR-1L-GL order code 23.0-1. AG for LTD (AL) pick-up | 19 | .2-0.5-0. I1×1.1) I1×1. AS. 05-1.9-0.1) I1×1. AI/MCR.95-1.35-0.4) 80-160-240-320-400-480-560 msec CP/I (Individval continuous contact) 1a for AL. AS.85-0.9-0. 1a for AG ✽applicable to APR-1L-GM type only Fault LED Individual control power voltage Field test | T1 : LTD time T2 : STD time TG : GFT time Tp : PTA time for AL. 1a for AP. I1×1.3-0. for general feeder oder code 27. AG. AI/MCR.05-1. AS.0) CT I0×(Non-0. for general feeder Characteristic I1 : LTD current I2 : STD current I3 : INST current IG : GFT current Ip : PTA current Type APR-1L-GS / APR-1L-GM Base current (l0) AL (LTD) Current (l1) Time (T1) Protection function AS (STD) AI (INST)/MCR AP (PTA) AG (GFT) Indication function Current (l2) Time (T2) Current (l3) Current (lP) Time (TP) Current (lG) Time (TG) 20 | Tolerance I ×(0.63-0.5-3-4-6-8-10) 80-160-240-320-400-480-560 msec. STD.75-0.8-0. AI/MCR. System alarm AC/DC100-250V for LTD. I2t is possible by ON/OFF I0×(Non-4-6-8-10-12-14-16) ICT×(0.5-0.2-0. AS. 1a for AG ✽applicable to APR-1L-GS type only IUt (Integrated continuous contact) 1a for AL.95-1.Air Circuit Breaker ACB Protection Relays APR-1L-GS APR-1L-GM order code 24.25-0.85-0. 1a for AP.1) 60-80-100-120-140-160-180-200 sec ICT×(Non-0.15-0.8-0.5% ±15% ±20% .8-1.05 Non Trip.0-1. AP.5-5-10-15-20-25-30 sec at I1×600% I0×(Non-2-2.2 Trip 0.25-2.5-1.1-0.0-1. INST by APR or APR checker ±15% ±15% ±20% ±7. AG.8-0. 1a for AG for AL. I1×1.5-3-4-6-8-10) 80-160-240-320-400-480-560 msec.95-1. | 21 | . AI by APR or APR checker ※ 1) LCD displays the current when it becomes 20% over than the rated current.9-0. 0.9-0.5-1.4) 80-160-240-320-400-480-560 msec Protection for N phase as well as R.75-0.05 Non Trip.25-2.8.35-0. AI/MCR. AS.5% ±15% ±20% ±2% 1a for AL.25-0.1 8 steps) I1×1.5.HiAN. AP AC/DC100-250V for AL.0-1. 1.05-1. HiAH & HiAS Type APR-2L-GS order code 25. 1a for AP. T ±15% ±15% ±20% ±7.5-5-10-15-20-25-30 sec at I1×600% I0×(Non-2-2. S.0-1. 0.15-0.8-0.05-1.85-0. for general feeder Characteristic I1 : LTD current I2 : STD current I3 : INST current IG : GFT current Ip : PTA current Type APR-2L-GS Base current (l0) AL (LTD) AS (STD) Protection function AI (INST)/MCR AP (PTA) AG (GFT) Indication function T1 : LTD time T2 : STD time TG : GFT time Tp : PTA time Time (T1) Current (l2) Time (T2) Current (l3) Current (lP) Time (TP) Current (lG) Time (TG) NP 1) CP/I (Individval continuous contact) Fault LED Individual control power voltage Field test Tolerance ICT×0.63. AS.0 I0×(Non-0.2-0. AI/MCR. AS.85-0. I2t is possible by ON/OFF I0×(Non-4-6-8-10-12-14-16) I0×(0.3-0.2 Trip 0.1-0.1) 60-80-100-120-140-160-180-200 sec ICT×(Non-0.95-1. 1 sec step at I1×600% (for general) at I1×300% (for motor) at I1×120% (for generator) Non. AI. 0. (I0)×40-120%. AI by APR or APR checker Ampere. for general feeder Characteristic I1 : LTD current I2 : STD current I3 : INST current IG : GFT current Ip : PTA current APR-1D-GM Type Current (l1) AL (LTD) Protection function AS (STD) AI (INST) AP (PTA) AG (GFT) Indication function Time (T1) Current (l2) Time (T2) Current (l3) Current (lP) Time (TP) Current (lG) Time (TG) CP/I (Individual contiuous contact) Fault LED Event memory Individual control power voltage Field test Measurement AMS (Communication) | 22 | T1 : LTD time T2 : STD time TG : GFT time Tp : PTA time Tolerance Non. 2% step 5-200 sec. (ICT)×10-40%.0 sec. 15-60 sec. (I0)×200-1600%. 10 msec step Non.Air Circuit Breaker ACB Protection Relays APR-1D-GM order code 26.5-30. 1a for AP for AL. AS. cos . Watt (W) RS-485 ±5% ±10% ±15% ±5% ±10% ±15% . AP Maximum 8 events can be memorized for fault AC/DC100-250V for AL. 20% step (I0)×32-120%.0 sec. AS. 1.0-5. AS. Frequency (Hz). AI/MCR. 20% step 80-560 msec. AG. (I0)×100-1000%.1 sec step 1 sec step 0. 10 msec step 1a for AL. 2% step 0. AG. Voltage. 20% step 80-560 msec. 1 sec step Non. 5-4-4.0 Trip 15-20-25-30-40-50-60 sec at I1×120% ±15% I0×(Non-2-2. HiAH & HiAS Type APR-1S-AL order code 28.5-5) ±15% 80-160-240-320-400-480-560 msec.9-1.HiAN.0).5-1. I t is possible by ON/OFF 2 I0×(Non-4-6-8-10-12-14-16) ±20% 1a.8-0.05-1.25) I1×1.5-2.0-1.15-1. 80ms ON for AL.7-3-3. AS. AI for LTD (AL) pick-up | 23 | .1-1.2-1. for generator Characteristic I1 : LTD current T1 : LTD time I2 : STD current T2 : STD time I3 : INST current Type Base current (l0) AL (LTD) Protection function AI (INST) Indication function Current (l1) Time (T1) AS (STD) Tolerance APR-1S-AL Current (l2) Time (T2) Current (l3) IU (Integrated instantaneous contact) Fault LED ICT×(0. 1% step I0×(Non-0. Air Circuit Breaker ACB Protection Relays APR-1S-AS order code 29.5-2.05-1.2-1.1) ±5% 5-10-15-20-25-30-35-40-45 sec at IP×120% ±15% CP/I (Individual contiuous contact) Fault LED Individual control power voltage | Tolerance Current (l3) Time (Tp) Field test T1 : LTD time T2 : STD time Tp : PTA time 0 1a for AL. AS.7-3-3.95-1.15-1.0-1.0 Trip 15-20-25-30-40-50-60 sec at I1×120% ±5% I0×(Non-2-2.05-1. for generator Characteristic I1 : LTD current I2 : STD current I3 : INST current Ip : PTA current Type APR-1S-AS Base current (l0) AL (LTD) Current (l1) Time (T1) Protection function Current (l2) AS (STD) Time (T2) AI (INST)/MCR AP (PTA) Indication function 24 | ICT×(0. AI/MCR.85-0.0).0-1. AI/MCR.9-0.5-4-4.8-1.5-1.5-5) ±10% 80-160-240-320-400-480-560 msec. AI by APR or APR checker ±20% .75-0.25) I1×1.8-0. 1a for AP for AL. System alarm AC/DC100-250V for AL. 1% step I0×(Non-0. I2t is possible by ON/OFF I0×(Non-4-6-8-10-12-14-16) Current (lp) I ×(0. AS.1-1. AP. AS. HiAH & HiAS Type Characteristic Curves General feeder ➊ GFT current setting range (10-40%) ➋ LTD current setting range (80-110%) ➌ PTA current setting range (75-110%) ➍ STD current setting range (200-1000%) ➎ INST current setting range (400-1600%) Generator ➊ LTD current setting range (80-125%) ➋ PTA current setting range (75-110%) ➌ STD current setting range (200-500%) ➍ INST current setting range (400-1600%) | 25 | .HiAN. Air Circuit Breaker APR Wiring Diagrams 3 pole Rn Sn Tn KC KB KA 4 pole Rn Sn Tn KC KB KA APR-1L-GL Rn Sn Tn KC KB KA Rn Sn Tn KC KB KA APR-1L-GS APR-2L-GS Rn Sn Tn KC KB KA APR-1L-GM | 26 | Rn Sn Tn KC KB KA . HiAN. HiAH & HiAS Type 3 pole Rn Sn Tn KC KB KA 4 pole Rn Sn Tn KC KB KA APR-1D-GM Rn Sn Tn KC KB KA Rn Sn Tn KC KB KA APR-1S-AL Rn Sn Tn KC KB KA Rn Sn Tn KC KB KA APR-1S-AS APR-2S-AS | 27 | . In case of draw-out type. the draw-in/out hole cover can be padlocked in connected. | 28 | [ HiAN40-63. HiAS06-32 ] ■ Draw-in/out handle The draw-in/out handle is supplied as a standard item.Air Circuit Breaker Accessories Standard components ■ Auxiliary switch The auxiliary switch electrically indicates close/open status of ACB. applicable load DC5V.6 load (A) DC: L/R≧0. ➋ Do not supply different voltages to contacts of a switch. HiAH32 ] draw-out type only . 1mA ※ ➊ The chattering of b-contacts due to ON-OFF operation of the ACB lasts for less than 20 ms.007 AC100-250V 5 5 0.1 0. [ HiAN06-32. and it is possible to prevent the draw-in/out of ACB in careless.01 Resistive load (A) Inductive AC: cosØ≧0.1 0. In case of HiAN06-32 and HiAS06-32 type.1 DC125-250V 1 1 - - Min.1 AC251-500V 5 5 - - DC30V 1 1 0. for general service ➊ Voltage for microload ➋ Resistive load (A) Inductive AC: cosØ≧0. test and isolated position. HiAS type is 3a3b. The diameter of padlock is 8 or 6. The connection parts are ring terminals. test and isolated position can be shown by position indicator. test and isolated. the auxiliary switch indicates the position of connected. the padlock is not supplied. and it is attached to the side of cradle. HiAN and HiAH type are 4a4b. ■ Position indicator and draw-in/out holes Connected.3 load (A) DC: L/R≧0. Max. ■ Door flange common / order code AG The door flange can cover the space between the panel cut-out and ACB. It can serve as the signal for maintanance or inspection. HiAH & HiAS Type Additional options ■ Key lock device (Lock in open) common / order code AB The key lock device prevents operation by unauthorized people.The key shall be removed only in open position of ACB. Lock in open system . (Unit: mm) Panel Cut-out Value for HiAN40-63 Min. The key lock device also enables the designing of an interlock system between ACBs and other devices such as switchboard door. It provides IP20 protection as well as makes the cut-out clean. . [ Interlock system for prevention of parallel closing from two breaker ] ACB 3 cannot be closed ACB 2 cannot be closed ■ Cycle counter ACB 1 cannot be closed common / order code AD The cycle counter shows the number of close/open cycle by a 5 digit display.HiAN.ACB cannot be closed without the release from open position. | 29 | . In case of 4 pole ACB with the ground fault trip protection function. draw-out type only / order code AH Vertical terminals (Unit: mm) ex) HiAN12. ■ Neutral line current transformer (Neutral CT) When you use 3 pole ACB with the ground fault trip protection function in 3-phase 4-line distribution system. 16 HiAS12. neutral line current transformer must be installed in the neutral line. ■ Button lock cover common / order code AM The botton lock cover is installed inside the ACB.Air Circuit Breaker Accessories ■ Lifting lugs common / order code AL The lifting lugs can be attached to the side of the ACB body for lifting. common / order code AN Wiring diagram for neutral CT ■ Vertical type bus-bar The vertical type bus-bar can be assembled to cradle for wide appication. 16 | 30 | . neutral CT is built in ACB as standard. It can enable locking in close function to prevent operation by mistake or unauthorized people. The key is not supplied. When the ACB is drawn out.HiAN. Interlock function shall be worked only in connected position. | 31 | . Panel cut-out (Unit: mm) ■ Spring charge switch common / order code B6 The spring charge switch electrically makes signal for charge condition of ACB. HiAH & HiAS Type ■ Mechanical interlock device common / order code B1-B4 2 or 3 ACBs can be interlocked mechanically by cables. ■ Extensional auxiliary switch common / order code AA The extensional auxiliary switch 1a1b can be supplied. and is installed in the cradle. Both horizontal and vertical mounting are available. Mechanical interlock can be realized between all range in same type ACB. the shutter can automatically shut down and cut the main circuit safely. ■ Non-flammable cable common / order code NC In case of power plant application. ■ Safety shutter draw-out type only / order code AE The safety shutter is composed of fixed and moving parts. non-flammable cables are recommended to use for better safety. connected: 1C and test: 1C . AT. .5A 6A 2A DC30V 6A 3A 6A 3A DC125V 0.isolated: 2C Operation sequence of contacts Isolated Test Connected Position switch ’a’ contact ON Connected position ’a’ contact ON Test position ’a’ contact ON Isolated position ’a’ contact ON Inserted position Short ’b’ contact | 32 | ’a’ contact ON Application Resistive load Lamp Inductive load Motor AC250V 10A 1.3A 0. AV The position switch electrically indicates connected. AS.inserted: 1C and isolated: 1C .test: 2C . and ‘a’ signal for connected position. AR. isolated and inserted position of ACB.connected: 2C . test.05A 0.1A DC250V 0. it is an essential item. ■ Position switch draw-out type only / order code AQ.1A 0. 6 Types are available.Air Circuit Breaker Accessories ■ Fixing blocks draw-out type only / order code AF The fixing blocks can be mounted on the cradle to fix the breaker against vibration.inserted: 1C .05A .6A 0. ■ Short circuit ‘b’ contact draw-out type only / order code AK The short circuit ‘b’ contact is used for interlock system to prevent wrong operation in test position.6A 0. It makes ‘b’ signal for test or isolated position. The short circuit ‘b’ contact is generally used for marine application. AU. and connection cables are not supplied. For marine application.3A 0. 100% size neutral pole is available for HiAN50 and HiAN63. HiAH & HiAS Type ■ Wrong inserting prevention device draw-out type only / order code AW The wrong inserting prevention device is composed of three plates and they are mounted on both ACB body and cradle.5m. ■ Arc shield draw-out type only / order code AX The arc shield is mounted on the top side of cradle to increase the safety level. Rated input voltage AC220V. ■ 100% size neutral pole HiAN50. HiAH type has 100% size neutral pole as standard.HiAN. It is a connector type. 50/60Hz Power consumption 10W Dimensions 220 (W)×90 (H)×150 (D)mm Weight 5kg | 33 | . ■ APR checker common / order code IANS H0C5 IANS H0C5 type portable APR checker enables easy inspection of ACB protection relay functions in the field. and the cable length is 3. 63 only / order code B5 In case of 4 pole HiAN and HiAS type ACBs. the size of the neutral pole is 50% of the other poles. Portable test equipment ■ Test jumper draw-out type only / order code IANS TJ The test jumper is used for the close/open operation test in drawn-out position. This device is used for prevention of wrong insertion between ACB body and cradle. HiAH32 1250 HiAN16. HiAH32 1600 HiAN20. HiAS32. HiAH32 3200 4EA×100mm×10mm 3200 3120 2930 2740 HiAN40 4000 3EA×140mm×10mm 4000 4000 3880 3560 HiAN50 5000 4EA×140mm×10mm 5000 5000 5000 4800 HiAN63 6300 6EA×140mm×10mm 6300 6300 6000 5800 . HiAH32 1250 HiAN16. HiAH32 800 HiAN10. HiAS12. HiAS06. HiAS10. HiAS20. Fixed type with horizontal mounting bus-bar Model Rated current (A) Bus-bar size HiAN06. HiAH32 2000 2EA×60mm×10mm 2000 2000 2000 2000 HiAN25. HiAS08. HiAH32 1600 HiAN20. HiAH32 3200 3EA×100mm×10mm 3200 3200 3020 2760 4EA×100mm×10mm 3200 3200 3200 3160 HiAN40 4000 3EA×140mm×10mm 4000 4000 3880 3560 HiAN50 5000 4EA×140mm×10mm 5000 5000 5000 4800 HiAN63 6300 6EA×140mm×10mm 6300 6300 6300 6048 Draw-out type with horizontal mounting bus-bar Model Rated current (A) Bus-bar size HiAN06. HiAS25. HiAH32 | 34 | 2000 Derated current by temperature of panel (max. HiAS32. HiAH32 800 HiAN10. HiAH32 630 HiAN08. HiAS10. HiAS25.)(A) 30℃ 40℃ 50℃ 60℃ 1EA×40mm×10mm 630 630 630 630 1EA×60mm×10mm 800 800 800 800 1EA×50mm×10mm 1000 1000 1000 900 1EA×60mm×10mm 1000 1000 1000 990 1EA×60mm×10mm 1250 1250 1140 990 2EA×40mm×10mm 1250 1250 1250 1150 2EA×40mm×10mm 1600 1480 1330 1150 2EA×50mm×10mm 1600 1600 1560 1350 2EA×60mm×10mm 1600 1600 1600 1540 2EA×60mm×10mm 2000 1980 1770 1540 2EA×80mm×10mm 2000 2000 2000 1890 2EA×100mm×10mm 2000 2000 2000 2000 2EA×80mm×10mm 2500 2430 2180 1890 2EA×100mm×10mm 2500 2500 2500 2220 3EA×100mm×10mm 3190 3010 2830 2590 HiAN25.)(A) 30℃ 40℃ 50℃ 60℃ 1EA×40mm×10mm 630 630 630 630 1EA×60mm×10mm 800 800 800 800 1EA×60mm×10mm 1000 1000 1000 1000 1EA×60mm×10mm 1250 1250 1250 1250 2EA×40mm×10mm 1250 1250 1250 1250 2EA×40mm×10mm 1600 1600 1600 1560 2EA×60mm×10mm 1600 1600 1600 1600 HiAN12. HiAS06.Air Circuit Breaker Derating Tables Derated current by the ambient temperature. HiAH32 2500 2EA×100mm×10mm 2500 2500 2500 2350 HiAN32. HiAS16. HiAS16. HiAH32 1000 HiAN12. HiAH32 1000 Derated current by temperature of panel (max. HiAH32 630 HiAN08. HiAH32 2500 HiAN32. HiAS12. HiAS20. HiAS08. HiAH32 HiAN32. HiAS12. HiAH32 HiAN25. HiAH32 800 Model HiAN10. HiAH32 HiAN12. HiAH32 HiAN20. HiAS25.)(A) 30℃ 40℃ 50℃ 60℃ 1EA×40mm×10mm 630 630 630 630 1EA×60mm×10mm 800 800 800 800 950 1EA×50mm×10mm 1000 1000 1000 1EA×60mm×10mm 1000 1000 1000 1000 1EA×60mm×10mm 1250 1250 1250 1100 2EA×40mm×10mm 1250 1250 1250 1250 2EA×40mm×10mm 1600 1600 1600 1440 2EA×50mm×10mm 1600 1600 1600 1580 2EA×60mm×10mm 1600 1600 1600 1600 2EA×60mm×10mm 2000 2000 2000 1920 2EA×80mm×10mm 2000 2000 2000 2000 2EA×100mm×10mm 2000 2000 2000 2000 2EA×80mm×10mm 2500 2500 2500 2360 2EA100mm×10mm 2500 2500 2500 2500 3EA×80mm×10mm 3200 3150 2950 2750 2EA×100mm×10mm 3190 3010 2830 2650 3EA×100mm×10mm 3200 3200 3070 2860 4EA×100mm×10mm 3200 3200 3200 3120 1250 1600 2000 2500 3200 HiAN40 4000 3EA×140mm×10mm 4000 4000 3880 3560 HiAN50 5000 4EA×140mm×10mm 5000 5000 5000 4800 HiAN63 6300 6EA×140mm×10mm 6300 6300 6000 5800 Internal Resistance HiAN & HiAH type HiAN06-10 HiAN12 HiAN16 HiAN20 HiAN25 HiAN32 HiAN40 HiAN50 HiAN63 HiAH32 Internal resistance (μ Ω) Draw-out type 66 48 48 30 24 22 20 15 10 21 Fixed type 38 20 20 16 14 13 - - - - Power consumption (W) Draw-out type 26/42/66 75 123 120 150 225 320 375 397 215 Fixed type 15/24/38 31 51 64 87. HiAH & HiAS Type Draw-out type with vertical mounting bus-bar Rated current (A) Bus-bar size HiAN06. HiAH32 HiAN16. HiAS08. HiAH32 1000 Derated current by temperature of panel (max.5 133 | 35 | . HiAS10. HiAS20.HiAN.5 133 - - - - HiAS type HiAS06-10 76 HiAS12 HiAS16 HiAS20 HiAS25 HiAS32 66 48 30 24 22 Internal resistance (μ Ω) Draw-out type Fixed type 48 38 20 16 14 13 Power consumption (W) Draw-out type 30/49/76 103 123 120 150 225 Fixed type 19/31/48 59 51 64 87. HiAH32 630 HiAN08. HiAS06. HiAS32. HiAS16. Air Circuit Breaker Circuit Diagrams HiAN & HiAH draw-out type ACB Protection Relay (over-current protection) Open Button Close Button Spring Charge Off Switch Antipumping Circuit ACB Protection Relay *1: Attach at rated voltage DC125V Motor Charging/Closing Circuits Main Circuit CT: Current Transformer for APR APR Protection Relay (over-current protection) 19 20 Control Power Terminal (CP/I) 22 24 AP Indication Terminal 25 26 AL AS 27 28 AG Indication Terminal AI Indication Terminal MHT Magnetic Hold Trigger Under Voltage Trip (UVT) 11 12 Control Power Terminal T1 T2 Remote Trip Terminal UVT Under Voltage Trip Coil Spring Charge Switch 15 16 Spring Charge Switch Terminal 1 2 Charging Power Terminal 3 4 Closing Power Terminal M Charging Motor LRC Latch Release Coil R1 Resistance Shunt Trip (SHT) 7 8 Control Power Terminal SHT Shunt Trip Coil Condenser Trip (CTD) Control Power Terminal U V P N Remote Trip Terminal CTD Condensor Trip Device Auxiliary Switch 31-46 Auxiliary Contact Terminal Position Switch TEST position 61-62 ON 61-63 OFF 64-65 ON 64-66 OFF | 36 | CONNECTED position 71-72 ON 71-73 OFF 74-75 ON 74-76 OFF ISOLATED position 81-82 ON 81-83 OFF INSERTED position 84-85 ON 84-86 OFF *2: Option (MCR) . HiAN. Switch Aux. HiAH & HiAS Type Open Button Position Switch (Short ’b’ contact) option Aux. Switch Open Button Auxiliary Switch Manufacturer wiring part User wiring part Disconnecting device Control Circuit Lay-out APR-1S-AS type APR ACB Draw-out Type 29 27 25 23 19 13 11 9 1 3 7 15 31 33 35 37 39 41 43 45 47 49 30 28 26 24 22 20 14 12 10 2 4 8 16 32 34 36 38 40 42 44 46 48 50 Circuit Switch Fixed Type Switch | 37 | . Air Circuit Breaker Circuit Diagrams HiAS type ACB Protection Relay (over-current protection) Open Button Close Button Spring Charge Off Switch ACB Protection Relay (APR-1L-GM) *1: Attach at rated voltage DC125V Motor Charging/Closing Main Circuit CT: Current Transformer for APR APR Protection Relay (over-current protection) 19 20 Control Power Terminal (CP/I) 22 25 AL AS AI Indication Terminal 26 27 AL AS AI Indication Terminal MHI Magnetic Hold Trigger Under Voltage Trip (UVT) 9 10 Control Power Terminal 1 2 Charging Power Terminal 3 4 Closing Power Terminal M Charging Motor LRC Latch Release Coil RI Resistance Shunt Trip (SHT) 7 8 Control Power Terminal SHT Shunt Trip Coil T1 T2 Remote Trip Terminal UVT Under Voltage Trip Coil Spring Charge Switch 15 16 Spring Chage Switch Terminal Capacitor Trip (CTD) Control Power Terminal U V P N Remote Trip Terminal CTD Condensor Trip Device Auxiliary Switch Position Switch TEST position 61-62 ON 61-63 OFF 64-65 ON 64-66 OFF | 38 | CONNECTED position 71-72 ON 71-73 OFF 74-75 ON 74-76 OFF 31 42 Auxiliary Contact Terminal . APR-1S-AL type APR APR-1L-GM type APR < Control Circuit > < Aux. Switch> | 39 | .HiAN. Switch Open Button Auxiliary Switch User wiring part Disconnecting device APR-1L-GL. HiAH & HiAS Type Manufacturer wiring part Control Circuit Lay-out Open Button Position Switch Aux. Switch Aux. 5 25 .5 ※ ❶ N is neutral pole of 4 pole breaker.5 98.5 F G H J I K Fixed type 10 PNL DOOR THICKNESS DOOR FRANGE ACB FRONT COVER Panel Cut-out CONTROL CIRCUIT TERMINALS 103.5 12 456.5 | 100 320 8 5x 7.5 40.5 1 32. 40 | T L M N O 40.5 100 P C P C 2- 103.5 122.4 8 115 345 5 122.5 12 330 115 345 5 122.5 4R5 292 100 P C 134 150 353.Air Circuit Breaker Dimensions HiAN06-32 with horizontal bus-bar Draw-out type X CONTROL CIRCUIT TERMINALS 292 FIXING BLOCKS (FOR MARINE) 103.5 8 383. ❷ Mounting angle is not supplied.5 4R5 W 12 Panel Cut-out Y V 7.9 33.5 1 2 7.4 (3P) 270 165.8 71 P C 103.5 122.2 8 5x 7. 3 244.3 199.3 213.3 209.3 168.8 384 HiAN25 100 80 60 50 20 15 12.5 333.3 319.5 90 105 105 160 160 167.3 154.5 168.4 T E 4.3 332.5 213.5 15 12.8 294 HiAN12 HiAN16 60 60 30 30 15 15 12.8 384 HiAN12 HiAN16 60 60 30 30 15 15 12.5 213.9 11 2 50 19.3 199.3 199.3 199.3 154.5 15 204 294 216 306 367.2 100 216 420 488.3 154.8 384 HiAN20 80 80 50 50 15 15 100 80 60 50 20 15 HiAN32 100 80 60 50 20 15 12.3 168.3 154.3 213.3 167.5 120 150 150 205 205 212.8 384 HiAN32 100 80 60 50 20 15 12.5 15 249 249 261 261 367.3 S 3 pole Dimensions (mm) Model B A C Draw-out Fixed Draw-out Fixed Draw-out Fixed D E F G H I J K L M N O T V W X Y Z S HiAN06 HiAN10 60 60 30 30 15 15 12.3 199.3 154.3 168.3 168.5 8 204 294 216 306 367.8 504 HiAN25 249 369 261 381 487.5 168.5 90 105 195 160 250 167.5 30 249 249 261 261 367.5 333.5 30 249 369 261 381 487.3 319.5 8 204 204 216 216 277.8 504 249 369 261 381 487.5 120 150 150 205 205 212.5 15 204 204 216 216 277.8 294 HiAN20 80 80 50 50 15 15 12.5 164 1 5 36.5 90 105 105 160 160 167.5 90 105 195 160 250 167.5 120 150 270 205 325 212.3 209.3 257.5 120 150 270 205 325 212.8 504 | 41 | .14 HOLEs 250 358 29.5 333.3 332. HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C 10 HiAN06-16 HiAN20-32 B ACB FRONT COVER 15 15 3- 2- D D ARC SHIELD(OPTION) 293.3 213.3 199.5 120 150 150 205 205 212.3 199.3 257.5 258.3 244.3 213.5 213.2 4 70.3 332.5 22 249 249 261 261 367.3 167.3 209.HiAN.5 258.3 199.3 319.8 384 4 pole Dimensions (mm) Model B A C Draw-out Fixed Draw-out Fixed Draw-out Fixed D E F G H I J K L M N O T V W X Y Z S HiAN06 HiAN10 60 60 30 30 15 15 12.3 199.3 154.6 A B C A DOOR FRANGE C PNL DOOR THICKNESS ISOLATED POSITION TEST POSITION CONNECTED POSITION 15 45 30 Z E E 312.3 213.5 22 12.3 213.5 120 150 270 205 325 212.1 EARTH TERMINAL MOUNT’G 73. 5 1 7.5 383.5 Y V CONTROL CIRCUIT TERMINALS 292 4R5 X F H J I K j- .5 12 345 8 115 5 122.5 32.5 40.5 12 j- j- m m m 5 12. ❷ Mounting angle is not supplied.2 330 8 5x 7.5 103. | 42 | 15 5 5 for HiAN20 G 15 for HiAN25-HiAN32 . 59 75 m m m 69 15 5 for HiAN06-HiAN16 ※ ❶ N is neutral pole of 4 pole breaker.5 12 .5 122.Air Circuit Breaker Dimensions HiAN06-32 with vertical bus-bar. draw-out type only 270 Panel Cut-out 100 P C W u t P C FIXING BLOCKS (FOR MARINE) 103. 8 156.5 201.8 105 195 160 250 167.8 321.5 e c’ 27.3 212.3 249 369 261 381 487.5 36.2 35.3 204 294 216 306 367.25 80 8 115 15 40 18 50 102.8 90 60 160.HiAN.8 321.3 35 201.8 150 150 205 205 212.75 60 108 8 30 16 30 92.8 HiAN25 150 270 205 325 212.1 358 a a EARTH TERMINAL MOUNT’G n a b 3 pole Dimensions (mm) Model HiAN06 HiAN10 HiAN12 HiAN16 HiAN20 F G H I J K V W X Y Z a b c’ d e f g h i j m n r t u 105 105 160 160 167.8 321. HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C 10 PNL DOOR THICKNESS DOOR FRANGE ACB FRONT COVER 293.25 15 117.5 100 f g 420 488.25 60 115 15 30 16 30 92.8 120 100 149.8 HiAN25 150 150 205 205 212.75 30 30 20 24 60 108.9 11 2 50 5 19.3 249 249 261 261 367.8 120 100 149.3 249 369 261 381 487.8 201.8 246.75 100 130 4 pole Dimensions (mm) Model HiAN06 HiAN10 HiAN12 HiAN16 HiAN20 F G H I J K V W X Y Z a b c’ d e f n r t u 105 195 160 250 167.8 90 60 157.5 156.3 249 369 261 381 487.3 212.3 204 204 216 216 277.9 1 4.8 120 100 153.2 4 70.3 212.8 201.3 167.8 156.8 HiAN32 150 270 205 325 212.3 204 294 216 306 367.3 249 249 261 261 367.2 35.25 15 127.3 167.2 35.8 HiAN32 150 150 205 205 212.14 HOLEs 250 29.8 105 105 160 160 167.8 120 80 157.3 40 201.3 40 201.8 99.5 156.75 100 122 22 20 24 60 108.8 120 80 157.25 80 8 115 15 40 24 50 102.2 35.8 120 100 153.75 60 108 8 30 12 30 92.3 35 201.2 35.75 22 103.3 257.75 130.8 90 60 157.6 ARC SHIELD(OPTION) ISOLATED POSITION d i TEST POSITION CONNECTED POSITION 15 30 Z 64 r MAX CONNECTING DISTANCE: r-3 286.3 332.75 130.5 156.25 60 115 15 30 12 30 92.3 332.75 100 122 22 20 18 60 108.75 100 130 | 43 | .25 15 117.3 332.4 h 18.25 15 127.5 156.8 150 270 205 325 212.8 90 60 160.5 201.3 257.2 35.8 201.75 30 30 20 18 60 108.8 246.75 22 103.3 204 204 216 216 277.8 g h i j m 99.3 249 249 261 261 367. 5 103.5 270 23.5 30 100 31.7 126 2. | 44 | 126 135 71.5 12 - 4 115 122.5 420 462 15 Side view 60 CONNECTED POSITION TEST POSITION ISOLATED POSITION 30 480. ❷ Mounting angle is not supplied.4 Rear view of 3 pole 3.11 TERMINAL MTG.1 44 2 250 407.6 286.5 345 X I J 7.1 4.5 26 100 30 330 477.14 MTG.2 481 ※ ❶ N is neutral pole of 4 pole breaker.1 2. draw-out type only Front view of 3 pole CONTROL CIRCUIT TERMINALS Panel Cut-out 292 4R5 100 103.5 30 40 15 MAX.6 7. CONNECT LENGHT 27. HOLEs 45.Air Circuit Breaker Dimensions HiAN40 with horizontal bus-bar.5 122. HOLEs PC(FRONT-COVER-CENTER-LINE) . 4 Rear view of 4 pole 100 26 126 126 126 1 PC(FRONT-COVER-CENTER-LINE) | 45 | . HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C Front view of 4 pole CONTROL CIRCUIT TERMINALS X I J 1 96 270 21 546 588 606.HiAN. 5 26 126 26 126 30 40 MAX.5 345 X I J 7.14 MTG. HOLEs PC(FRONT-COVER-CENTER-LINE) .2 Side view TEST POSITION ISOLATED POSITION 100 480. 71. ❷ Mounting angle is not supplied.5 12 - 4 115 122. CONNECT LENGHT 250 481 ※ ❶ N is neutral pole of 4 pole breaker. draw-out type only Front view of 3 pole CONTROL CIRCUIT TERMINALS Panel Cut-out 292 4R5 100 103.1 45.6 35 100 35 35 140 20 100 27.Air Circuit Breaker Dimensions HiAN40 with vertical bus-bar.6 7.1 44 2 407.7 17. HOLEs Rear view of 4 pole 135 15 10.5 270 23.4 2.5 4.5 420 462 CONNECTED POSITION 15 30 M12 SUPPLIED AS STANDARD 115.5 40 477.11 TERMINAL MTG.5 122.2 | 46 | 286.5 55 35 35 35 140 330 43 17.5 78 4- 13 31.5 103. HiAN.4 Rear view of 4 pole 26 126 1 26 126 26 126 PC(FRONT-COVER-CENTER-LINE) | 47 | . HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C Front view of 4 pole CONTROL CIRCUIT TERMINALS X I J 1 96 270 21 546 588 606. 1 71. HOLEs 141.3 30 (HiAN63) 30 (HiAN63) 286.7 135 330 477.5 348 270 21 798 840 858. and the size is 50% of other poles.5 22 188.5 .5 6- Side view CONNECTED POSITION TEST POSITION ISOLATED POSITION Rear view of 3 pole 15 ACB FRONT COVER 30 60 30 66 222 60 5. 100% size is available as option.14 MTG.5 103.5 122.7 474. draw-out type only Front view of 3 pole CONTROL CIRCUIT TERMINALS Panel Cut-out 292 4R5 100 103.4 10 DOOR FLANGE MAX.5 HiAN50 252 30 188.1 44 4.2 252 30 PC(FRONT-COVER-CENTER-LINE) 2.Air Circuit Breaker Dimensions HiAN50-63 with horizontal bus-bar.5 100 31. | 48 | 22 63 188.5 5x8 12- 7.11 TERMINAL MTG.6 188.5 115 X I J 7.14 MTG. HOLEs 27.5 ※ ❶ N is neutral pole of 4 pole breaker.5 33.6 5 8 345 122. HOLEs 2 250 407.5 HiAN50 101.5 23. refer to page 22 ❷ Mounting angle is not supplied. CONNECT 40 LENGHT PNL DOOR THICKNESS REAL PANEL (NOT SUPPLIED) 15 30 12 . 4 12 . 60 30 30 (HiAN63) 30 (HiAN63) 3- Rear view of 4 pole 100 1 PC(FRONT-COVER-CENTER-LINE) | 49 | .14 MTG.5 6- 220 60 5.HiAN. HOLEs 220 220 252 30 63 220 252 30 22 HiAN50 100 22 189 28 30 66 222 HiAN50 30 60 15 5 12. HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C Front view of 4 pole CONTROL CIRCUIT TERMINALS X I 348 J 270 21 924 966 MAX. CONNECT 40 LENGHT 984. 5 345 X I J 7.5 122.5 | 10. ❷ Mounting angle is not supplied.Air Circuit Breaker Dimensions HiAN50-63 with vertical bus-bar.5 55 35 35 35 140 17.5 4 115 122.5 188. 50 | 100 286.5 PC(FRONT-COVER-CENTER-LINE) HiAN50 REAL PANEL (NOT SUPPLIED) 22 15 30 HiAN50 CONNECTED POSITION .7 17.3 78 13 30 (HiAN63) 30 (HiAN63) 115. HOLEs 40 MAX. HOLEs 2 250 407. CONNECT LENGHT 2.6 12 - 7.5 4-R 5 348 270 21 798 840 858. draw-out type only Front view of 3 pole CONTROL CIRCUIT TERMINALS Panel Cut-out 292 103.4 Side view Rear view of 3 pole 15 ISOLATED POSITION TEST POSITION 188.5 31.5 188.2 222 101.1 44 4.11 TERMINAL MTG.5 188.5 23.14 MTG.5 100 103. HOLEs 100 435 35 35 140 20 10.6 330 43 5.5 40 477.1 45.2 481 ※ ❶ N is neutral pole of 4 pole breaker.5 22 30 252 63 30 252 135 71.2 27.14 MTG. 2 100 HiAN50 10.14 MTG.HiAN.2 222 HiAN50 10.2 100 1 PC(FRONT-COVER-CENTER-LINE) | 51 | .2 5. HOLEs 220 220 220 28 30 252 63 30 252 22 189 100 22 30 (HiAN63) 30 (HiAN63) 220 10.4 Rear view of 4 pole 15 15 M12 SUPPLIED AS STANDARD 10. HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C Front view of 4 pole CONTROL CIRCUIT TERMINALS X I 348 J 270 21 924 966 984. draw-out type only Front view Panel Cut-out 103.5 4 115 122.5 31. CONNECT 40 LENGHT [ Horizortal bus-bar ] 30 60 30 66 222 5.6 12 - 7.5 Side view 6- MAX.5 1 2.5 23.5 43 252 63 22 22 252 30 251. HOLEs 27.5 122. 4 pole with 100% size N pole.4 ISOLATED POSITION TEST POSITION CONNECTED POSITION REAL PANEL (NOT SUPPLIED) 15 30 Rear view 12 .3 30 (HiAN63) 30(HiAN63) 286. HOLEs 2 250 407.Air Circuit Breaker Dimensions HiAN50-63.1 44 4.11 TERMINAL MTG.2 481 ※ ❶ N is neutral pole of 4 pole breaker. HOLEs PC (FRONT-COVER-CENTER-LINE) HiAN50 251.5 100 71.5 HiAN50 101. ❷ Mounting angle is not supplied. | 52 | 252 251.5 .5 4-R 5 CONTROL CIRCUIT TERMINALS 348 270 21 1050 1092 1110.7 135 330 477.5 292 100 103.1 45.5 345 X I J 7.6 251.14 MTG.14 MTG. CONNECT LENGHT 2.5 35 35 35 40 140 286.5 30 252 63 251.HiAN.5 35 35 35 55 140 71. HOLEs 2 250 407.14 MTG.2 10.5 1 43 22 100 22 HiAN50 HiAN50 (HiAN63) 30 251.5 27.5 30 252 (HiAN63) 30 30 252 251. HOLEs 251.11 TERMINAL MTG.2 165 HiAN50 22 30 HiAN63 100 HiAN50 22 30 HiAN63 13 17.5 PC (FRONT-COVER-CENTER-LINE) | 53 | .2 222 5. HiAH & HiAS Type (Unit: mm) [ Vertical bus-bar ] P: Front PNL Center Line C Side view CONNECTED POSITION TEST POSITION ISOLATED POSITION REAL PANEL (NOT SUPPLIED) 45.6 15 30 40 MAX.5 115.5 78 20 43 31.1 477.7 330 4- 17. HOLEs 481 Rear view 15 10.1 44 4.14 MTG. Air Circuit Breaker Dimensions HiAH32, draw-out type only Front view of 3 pole CONTROL CIRCUIT TERMINALS Panel Cut-out 292 103.5 100 103.5 345 115 122.5 4R5 7.5 122.5 12 - 4 I 270 23.6 7.5 M12 BOLT 420 462 480.4 Front view of 4 pole CONTROL CIRCUIT TERMINALS PC (FRONT-PANEL-CENTER-LINE) I 1 M12 BOLT 96 21 270 546 588 606.4 ※ ❶ N is the neutral pole for 4 pole ACB. ❷ Mounting angle is not supplied. | 54 | HiAN, HiAH & HiAS Type (Unit: mm) [ Horizortal bus-bar ] P: Front PNL Center Line C Side view Rear view MAX. CONNECT LENGHT 40 CONNECTED POSITION 15 30 27.5 30 15 TEST POSITION ISOLATED POSITION 60 126 126 26 100 22 330 477.6 286.5 22 100 126 71.7 143 126 31.1 4- 14 MTG. HOLEs 45.1 44 2 126 1 PC (FRONT-COVER-CENTER-LINE) (4P) 2- 11 TERMINAL MTG. HOLEs 250 126 (3P) 462 407.2 588 481 [ Vertical bus-bar ] Rear view Side view 126 126 126 CONNECTED POSITION TEST POSITION REAL PANEL (NOT SUPPLIED) ISOLATED POSITION 15 30 27.5 10.2 4- 14 MTG. HOLEs 45.1 44 2 30 HiAN63 100 71.7 HiAN50 22 HiAN50 22 286.5 35 31.1 17.5 55 35 35 35 140 17.5 40 477.6 330 43 40 MAX. CONNECT LENGHT 250 407.2 481 10.2 100 35 35 140 20 13 165 4- 30 HiAN63 115.5 78 1 PC (FRONT-COVER-CENTER-LINE) 2- 11 TERMINAL MTG. HOLEs | 55 | Air Circuit Breaker Dimensions HiAS06-32 with horizontal bus-bar Draw-out type X V Panel Cut-out Y W AUXILIARY SWITCH TERMINALS CONTROL CIRCUIT TERMINALS 292 103.5 4-R 100 FIXING BLOCKS (FOR MARINE) 103.5 P C 2- 8 383.2 115 345 5 122.5 12 5 8 5x 7.5 122.5 1 32.5 12 7.5 F G H I J K Fixed type 10 PNL DOOR THICKNESS DOOR FRANGE Panel Cut-out ACB FRONT COVER CONTROL CIRCUIT TERMINALS (SCREWLESS TYPE) 103.5 99 P C 71 103.5 T 100 456.4 8 115 345 5 122.5 4R5 292 100 P C 8 5x ※ ❶ N is the neutral pole for 4 pole ACB. ❷ Mounting angle is not supplied. | 56 | 33.4 270 L N (3P) M O 40.9 1 2 7.5 165.5 45 7.5 122.5 12 134 150 25 5 4 19.14 HOLEs 2 29.3 168.3 167.3 209.3 199.5 120 150 150 205 205 212.3 168.8 384 HiAS20 80 80 50 50 15 15 12.3 244.3 332.5 120 150 270 205 325 212.3 199.8 358 S 73.3 257.3 319.3 213.2 50 15 1 11 4.2 B 100 420 C HiAS20-32 216 250 5 EARTH TERMINAL MOUNT’G 35.5 90 105 105 160 160 167.3 154.3 154.3 168.3 199.3 167. HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C 10 PNL DOOR THICKNESS DOOR FRANGE ACB FRONT COVER ARC SHIELD(OPTION) 316.5 8 204 204 216 216 277.5 15 204 204 216 216 277.3 319.9 65 ISOLATED POSITION 15 30 HiAS06-16 B C A TEST POSITION CONNECTED POSITION 45 2- Z T E E D 15 E D 3- 164 70.5 15 249 249 261 261 367.3 199.5 90 105 105 160 160 167.5 333.3 154.5 333.3 244.3 213.8 384 HiAS32 80 80 60 50 20 15 12.8 294 HiAS20 80 80 50 50 15 15 12.8 384 HiAS12 55 60 30 30 15 15 12.5 120 150 270 205 325 212.3 213.5 90 105 195 160 250 167.5 22 249 369 261 381 487.5 258.5 15 249 369 261 381 487.3 213.5 213.8 504 HiAS32 80 80 60 50 20 15 12.3 213.3 332.5 22 249 249 261 261 367.3 209.3 332.5 8 204 294 216 306 367.5 90 105 195 160 250 167.5 258.3 244.3 167.5 168.5 30 249 249 261 261 367.8 294 HiAS12 55 60 30 30 15 15 12.3 213.3 319.5 90 105 195 160 250 167.3 154.5 30 249 369 261 381 487.3 154.5 258.8 384 HiAS16 80 60 30 30 15 15 12.8 504 HiAS25 80 80 60 50 20 15 12.3 154.5 120 150 150 205 205 212.3 168.5 213.5 213.8 294 HiAS16 80 60 30 30 15 15 12.5 90 105 105 160 160 167.3 154.3 168.3 257.8 504 | 57 | .9 A 312.3 199.5 120 150 270 205 325 212.3 199.5 333.3 257.3 168.3 154.5 15 204 294 216 306 367.5 15 204 294 216 306 367.3 199.HiAN.3 209.8 384 4 pole Dimensions (mm) Model B A C Draw-out Fixed Draw-out Fixed Draw-out Fixed D E F G H I J K L M N O T V W X Y Z S HiAS06 HiAS10 45 60 30 30 15 15 12.5 168.5 168.5 15 204 204 216 216 277.3 199.3 154.8 384 HiAS25 80 80 60 50 20 15 12.3 199.5 120 150 150 205 205 212.3 3 pole Dimensions (mm) Model B A C Draw-out Fixed Draw-out Fixed Draw-out Fixed D E F G H I J K L M N O T V W X Y Z S HiAS06 HiAS10 45 60 30 30 15 15 12. | 58 | 15 5 HiAS20 5 15 HiAS25-HiAS32 .5 122.5 2- 383.5 1 32.Air Circuit Breaker Dimensions HiAS06-32 with vertical bus-bar. ❷ Mounting angle is not supplied. .5 12 j- 59 e c’ 15 5 HiAS06-HiAS16 ※ ❶ N is the neutral pole for 4 pole ACB.5 Y V 7.5 12 345 8 115 5 122.5 F G H J I K j- j- 75 m m 69 m g f m m m h 5 12. draw-out type only X Panel Cut-out 100 P C AUXILIARY SWITCH TERMINALS FIXING BLOCKS (FOR MARINE) 103.2 8 5x 7.5 12 .5 12 4-R5 W CONTROL CIRCUIT TERMINALS 292 103. 3 249 369 261 381 367.5 HiAS12 HiAS16 105 195 160 250 167.14 HOLEs 2 a 250 358 5 b EARTH TERMINAL MOUNT’G 35.3 204 294 216 306 277.3 257.8 384 90 45 160.3 212.8 504 120 80 157.25 60 115 15 35 16 30 92.8 504 120 80 153.3 35 HiAS32 150 150 205 205 212.3 332.5 HiAS12 HiAS16 105 105 160 160 167. HiAH & HiAS Type (Unit: mm) P: Front PNL Center Line C 10 PNL DOOR THICKNESS DOOR FRANGE ACB FRONT COVER ARC SHIELD(OPTION) 316.5 HiAS20 150 270 205 325 212.3 204 204 216 216 277.8 294 90 55 157.75 22 103.3 249 369 261 381 367.2 35.2 1 29.2 420 216 d i 64 r 100 15 4 19.3 249 249 261 261 367.3 257.25 60 115 15 35 12 30 92.3 204 204 216 216 277.8 384 120 80 153.2 35.8 384 120 80 157.75 100 130 30 40 24 60 108.25 15 117.5 35.3 249 249 261 261 367.3 167.75 100 122 22 40 24 60 108.75 60 108 8 45 12 30 92.5 HiAS25 150 150 205 205 212.3 40 g h i j m 8 99.2 35.3 332.25 15 127.75 130.3 249 369 261 381 367.3 249 249 261 261 367.35 80 115 15 40 18 50 102.5 35.75 130.3 167.3 204 294 216 306 277.75 60 108 8 45 16 30 92.75 22 103.2 35.75 100 130 4 pole Dimensions (mm) Model F G H I J K V W X Y Z S a b c’ d e f n r HiAS06 HiAS10 105 195 160 250 167.8 384 90 55 157.75 100 122 22 40 18 60 108.3 212.3 40 8 | 59 | .HiAN.8 384 120 80 149.75 30 99.75 30 30 40 18 60 108.5 HiAS25 150 270 205 325 212.5 HiAS20 150 150 205 205 212.9 65 ISOLATED POSITION TEST POSITION CONNECTED POSITION 30 Z 312.25 80 115 15 40 24 50 102.25 15 117.8 n S 3 pole Dimensions (mm) Model F G H I J K V W X Y Z S a b c’ d e f g h i j m n r HiAS06 HiAS10 105 105 160 160 167.3 212.9 50 a a 11 4.8 504 120 80 149.25 15 127.3 332.3 35 HiAS32 150 270 205 325 212.8 294 90 45 160. M2 M5 23 Code APR type Function Without APR General feeder Motor / AC220V 23 APR-1L-GL AL. AS. AI. AP. AG / CP/I-LED. AG. AP. LCD Generator IAN40 HiAN40 28 APR-1S-AL AL. no. MCR / IUt. AI. AS. AG / CP/I-LED M6 Motor / DC220V 27 APR-1L-GM AL. AS. AG. CP/I. AS. LED HiAN06 IAN08 HiAN08 IAN10 HiAN10 IAN12 HiAN12 IAN16 IAN20 IAH32 HiAH32 HiAS type 60 D 00 IAN06 IAN63 HiAN63 HiAH type | 3 IAS06 HiAS06 IAS08 HiAS08 IAS10 HiAS10 IAS12 HiAS12 IAS16 HiAS16 IAS20 HiAS20 IAS25 HiAS25 IAS32 HiAS32 AL. AS. NP. MCR / CP/I. . LED / LCD ※ In case of HiAS type. 23. AI. AI / IU IAN50 HiAN50 29 APR-1S-AS AL. 27 and 28 shall be orderd. AI. LED HiAN16 M7 Motor / DC24V HiAN20 M8 Motor / DC48V 25 APR-2L-GS IAN25 HiAN25 M9 Motor / DC125V 26 IAN32 HiAN32 APR-1D-GM AL. AP. AI.Air Circuit Breaker Order Information IAN06 Code Model name HiAN type | M2 Code Mounting Code Charging operation Code Pole 3 3 pole F 1) Fixed type H0 Manual 4 4 pole D Draw-out type M1 Motor / AC110V ※ 1) HiAN40-63 and HiAH32 are not applicable. AP. AS. AS. AG / IU Motor / DC110V 24 APR-1L-GS AL. AI. AP. MCR. ) / AC380V AK Short circuit ‘b’ contact U4 UVT (Inst. test: 1C U5 UVT (Inst.) / AC440V AQ Position switch / conn: 1C. 2ST T2 UVT (Delay) / AC220V P 3200A 32-40 32 32 B4 Mechanical interlock device / Vert. isolated: 1C D1 S1 + T1 / AC110V AU Position switch / inserted: 1C D2 S2 + T2 / AC220V AV Position switch / Isolated: 1C D3 S3 + T3 / AC380V AW Wrong inserting prevention device D4 S4 + T4 / AC440V AX Arc shield X1 S5 / DC110V + T3 / AC380V B5 100% size natural pole for HiAN50-63 X2 S1 / AC110V + T3 / AC380V X3 S7 / DC24V + T4 / AC440V X4 S7 / DC24V + T2 / AC220V W1 S1 / AC110V + T2 / AC220V W2 S1 / AC110V + T4 / AC440V W3 S2 / AC220V + T4 / AC440 W4 S5 / DC110V + T1 / AC110V W5 S5 / DC110V + T2 / AC220V W6 S5 / DC110V + T4 / AC440V W7 S5 / DC110V + T5 / AC480V Shunt and Instantaneous type UVT I1 S1 + U1 / AC110V I2 S2 + U2 / AC220V I3 S3 + U3 / AC380V I4 S4 + U4 / AC440V I5 S5 / DC110V + U5 / DC100V I6 S6 + U6 / DC220V + U6 / DC200V Condensor trip device C1 CTD / AC110V C2 CTD / DC220V | 61 | . for HiAN06-32 Common use S1 Shunt / AC110V I 80A 06-16 06-16 06-16 S2 Shunt / AC220V B 160A 06-16 06-16 06-16 AB Key lock device / lock in open S3 Shunt / AC380V V 320A 06-16 06-16 06-16 AD Cycle counter S4 Shunt / AC440V T 630A 06-16 32 06-16 AG Door flange S5 Shunt / DC110V H 800A 08-16 32 08-16 AL Lifting lugs S6 Shunt / DC220V J 1000A 10-32 32 10-32 AM Button lock cover S7 Shunt / DC24V K 1250A 12-16 32 12-16 AN Neutral CT for 3 pole S8 Shunt / DC48V Under voltage trip / Time delay type L 1600A 16-32 32 16-32 B1 Mechanical interlock device / Hori.) / AC110V AF Fixing blocks U2 UVT (Inst...HiAN.) / AC220V AH Vertical type bus-bar for draw-out type U3 UVT (Inst. HiAH & HiAS Type S2 Code Electrical trip device Shunt trip T ABADAE Rated primary Applied ACB Code current (ICT) HiAN HiAH HiAS of APR All All All 0 Without CT Code Additional options AA Extensional auxillary switch / 1a1b..) / DC100V AR Position switch / conn: 2C U6 UVT (Inst. 2ST M 2000A 20-32 32 20-32 B2 Mechanical interlock device / Hori.. 3ST T3 UVT (Delay) / AC380V Q 4000A 40-63 B6 Spring charge switch T4 UVT (Delay) / AC440V S 5000A 50-63 NC T5 UVT (Delay) / AC480V Under voltage trip / Instantenous type X 6300A 63 Non-flammable cable Draw-out type only AE Safety shutter U1 UVT (Inst. 3ST T1 UVT (Delay) / AC110V N 2500A 32-40 32 25-32 B3 Mechanical interlock device / Vert.) / DC200V Shunt and Delay type UVT AS Position switch / test: 2C AT Position switch / inserted: 1C. AC220V 06-32 IANS U2U6 Under voltage trip unit Instantaneous type. AC480V 06-32 IANS T5U6 Under voltage trip unit Time delay type. AC110V 06-32 IANS U1U6 Under voltage trip unit Instantaneous type.Air Circuit Breaker Order Information Spare parts Code Description Name Applied ACB Specification HiAN HiAH HiAS ACB order code Category Spare parts based on ACB main order code | 62 | IANS M1U Charging motor unit AC110V 06-32 IANS M16U Charging motor unit AC110V 40-63 IANS M2U Charging motor unit AC220V 06-32 IANS M26U Charging motor unit AC220V 40-63 IANS M5U Charging motor unit DC110V 06-32 IANS M56U Charging motor unit DC110V 40-63 IANS M6U Charging motor unit DC220V 06-32 IANS M66U Charging motor unit DC220V 40-63 IANS M7U Charging motor unit DC24V 06-32 IANS M76U Charging motor unit DC24V 40-63 IANS M8U Charging motor unit DC48V 06-32 IANS M86U Charging motor unit DC48V 40-63 IANS M9U Charging motor unit DC125V 06-63 IANS M96U Charging motor unit DC125V 40-63 32 IANS 23U ACB protection relay APR-1L-GL 06-63 32 IANS 24U ACB protection relay APR-1L-GS 06-63 32 IANS 27U ACB protection relay APR-1L-GM 06-63 32 IANS 25U ACB protection relay APR-2L-GS 06-63 32 IANS 26U ACB protection relay APR-1D-GM 06-63 32 IANS 28U ACB protection relay APR-1S-AL 06-32 32 IANS 29U ACB protection relay APR-1S-AS 06-63 32 IANS S1U Shunt trip unit AC110V 06-32 IANS S16U Shunt trip unit AC110V 40-63 IANS S2U Shunt trip unit AC220V 06-32 IANS S26U Shunt trip unit AC220V 40-63 IANS S3U Shunt trip unit AC380V 06-32 IANS S36U Shunt trip unit AC380V 40-63 IANS S4U Shunt trip unit AC440V 06-32 IANS S46U Shunt trip unit AC440V 40-63 IANS S5U Shunt trip unit DC110V 06-32 IANS S56U Shunt trip unit DC110V 40-63 IANS S6U Shunt trip unit DC220V 06-32 IANS S66U Shunt trip unit DC220V 40-63 IANS S7U Shunt trip unit DC24V 06-32 IANS S76U Shunt trip unit DC24V 40-63 IANS S8U Shunt trip unit DC48V 06-32 IANS S86U Shunt trip unit DC48V 40-63 IANS T1U Under voltage trip unit Time delay type. AC480V 40-63 IANS U1U Under voltage trip unit Instantaneous type. AC380V 06-32 IANS T3U6 Under voltage trip unit Time delay type. AC440V 40-63 IANS T5U Under voltage trip unit Time delay type. AC220V 40-63 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 06-32 M2 M5 M6 M7 M8 M9 23 24 06-32 27 25 26 06-32 28 29 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 M1 S1 S2 S3 S4 S5 S6 S7 S8 T1 T2 T3 T4 T5 U1 U2 ACB A9 . AC110V 40-63 IANS T2U Under voltage trip unit Time delay type. AC440V 06-32 IANS T4U6 Under voltage trip unit Time delay type. AC220V 06-32 IANS T2U6 Under voltage trip unit Time delay type. AC110V 40-63 IANS U2U Under voltage trip unit Instantaneous type. AC380V 40-63 IANS T4U Under voltage trip unit Time delay type. AC220V 40-63 IANS T3U Under voltage trip unit Time delay type. AC110V 06-32 IANS T1U6 Under voltage trip unit Time delay type. for 4 pole 06-32 IANS 253AA Extensional auxiliary switch 1a1b.2A. for 4 pole 06-32 IANS 323AA Extensional auxiliary switch 1a1b.2A. DC100V 40-63 IANS U6U Under voltage trip unit Instantaneous type. 1EA.2A. for 3 pole 25-32 32 25-32 IANS NCT332E Neutral CT 3200/0. for 4 pole 06-32 IANS 203AA Extensional auxiliary switch 1a1b.2A. for draw-out type 06-16 06-16 B3 IANS 332F Mechanical interlock device Vertical connection. for 3 pole 16-32 32 16-32 IANS NCT220E Neutral CT 2000/0. for fixed type 20-32 20-32 B4 IANS 332 Mechanical interlock device Vertical connection. for draw-out type 06-16 06-16 B1 IANS 132F Mechanical interlock device Horizontal connection. 1EA.2A. for 3 pole 06-16 06-16 IANS NCT032E Neutral CT 320/0. AC440V 40-63 IANS U5U Under voltage trip unit Instantaneous type. for draw-out type 20-32 20-32 IANS 316F Mechanical interlock device Vertical connection. for 3 pole 06-32 IANS 164AA Extensional auxiliary switch 1a1b. for fixed type 20-32 20-32 B2 IANS 132 Mechanical interlock device Horizontal connection. for draw-out type 20-32 20-32 for gray color front cover AA 06-32 06-32 32 06-32 06-32 32 06-32 06-63 06-32 06-32 32 06-32 AB AD AG AL AM AN | 63 | . for 3 pole 06-16 06-16 IANS NCT063E Neutral CT 630/0. for 3 pole 06-16 32 06-16 IANS NCT080E Neutral CT 800/0. for 3 pole 06-32 IANS 204AA Extensional auxiliary switch 1a1b. HiAH & HiAS Type Description Code Name Applied ACB Specification HiAN HiAH HiAS ACB order code IANS U3U Under voltage trip unit Instantaneous type. 1EA. 1EA. for fixed type 06-16 06-16 IANS 316 Mechanical interlock device Vertical connection.HiAN. for 3 pole 06-32 IANS 254AA Extensional auxiliary switch 1a1b. for 3 pole 08-16 32 08-16 IANS NCT110E Neutral CT 1000/0. AC380V 06-32 IANS U3U6 Under voltage trip unit Instantaneous type.2A. 1EA. for 3 pole 32-40 32 32 IANS NCT440E Neutral CT 4000/0.2A. DC100V 06-32 IANS U5U6 Under voltage trip unit Instantaneous type. for 3 pole 20-32 32 20-32 IANS NCT225E Neutral CT 2500/0.2A. AC440V 06-32 IANS U4U6 Under voltage trip unit Instantaneous type. 1EA.2A. 1EA. for 3 pole 40-63 IANS 116F Mechanical interlock device Horizontal connection. DC200V 40-63 32 HVFS-T4 Condensor trip device AC110V 06-63 32 06-32 C1 HVFS-T7 Condensor trip device AC220V 06-63 32 06-32 C2 06-32 32 06-32 32 06-32 32 06-32 Category U3 U4 ACB A9 VCB V9 ACB A9 U5 U6 Spare parts based on ACB additional option order code for common use IANS 103AA Extensional auxiliary switch 1a1b.2A. for 4 pole 06-32 IANS KL/B Key lock device lock in open 06-32 IANS KL/B-63 Key lock device lock in open 40-63 32 IANS CK Cycle counter 5 digits 06-63 32 IANS DP Door flange for gray color front cover 06-32 IANS DP63 Door flange 06-63 IANS LL Lifting lugs 06-32 IANS LL/63 Lifting lugs 40-63 IANS BL Button lock cover IANS BL63 Button lock cover IANS NCT016E Neutral CT 160/0. 1EA. for 3 pole 06-32 IANS 104AA Extensional auxiliary switch 1a1b. for 3 pole 06-32 IANS 324AA Extensional auxiliary switch 1a1b. 1EA. 1EA. for 3 pole 12-16 32 12-16 IANS NCT116E Neutral CT 1600/0. for 3 pole 10-32 32 10-32 IANS NCT113E Neutral CT 1250/0. for 4 pole 06-32 IANS 163AA Extensional auxiliary switch 1a1b.2A. for fixed type 06-16 06-16 IANS 116 Mechanical interlock device Horizontal connection. 1EA. DC200V 06-32 IANS U6U6 Under voltage trip unit Instantaneous type. AC380V 40-63 IANS U4U Under voltage trip unit Instantaneous type. 2A. 1EA IANS DI16P DI unit Arc chamber. 1EA 25-32 32 25-32 IANS CT332E Current transformer 3200/0.2A.: 1C. for 1 pole 06-16 06-16 IANS DI32P DI unit Arc chamber.2A. 1EA 50-63 IANS CT663E Current transformer 6300/0. 1EA 08-16 32 08-16 IANS CT110E Current transformer 1000/0.2A. 1EA 10-32 32 10-32 IANS CT113E Current transformer 1250/0.Air Circuit Breaker Order Information Spare parts Description Code Name Applied ACB Specification HiAN HiAH HiAS ACB order code Category Spare parts based on ACB additional option order code for draw-out type IANS CA163S Safety shutter for 3 pole 06-16 06-16 IANS CA164S Safety shutter for 4 pole 06-16 06-16 IANS CA323S Safety shutter for 3 pole 20-32 20-32 IANS CA324S Safety shutter for 4 pole 20-32 IANS CA403S Safety shutter for 3 pole 40 32 IANS CA404S Safety shutter for 4 pole 40 32 IANS CA503S Safety shutter for 3 pole 50-63 IANS CA504S Safety shutter for 4 pole 50-63 IANS FB Fixing blocks 06-32 IANS FB63 Fixing blocks 40-63 32 IANS SB short circuit ‘b’ contact 06-63 32 06-32 AK IANS PS-SW Position switch conn.2A.2A. Wrong inserting prevention device 06-63 32 06-32 AW IANS AB163 Arc shield for 3 pole 06-16 06-16 IANS AB164 Arc shield for 4 pole 06-16 06-16 IANS AB323 Arc shield for 3 pole 20-32 20-32 IANS AB324 Arc shield for 4 pole 20-32 IANS AB403 Arc shield for 3 pole 40 32 IANS AB404 Arc shield for 4 pole 40 32 IANS AB503 Arc shield for 3 pole 50-63 IANS AB504 Arc shield for 4 pole 50-63 20-32 06-32 20-32 AE AF ACB A9 ACB A9 ACB A9 AX Portable test equipments IANS TJ Test jumper 06-63 32 06-32 IANS H0C5 APR checker 06-63 32 06-32 Spare parts for general replacement | 64 | IANS ANTI110 Anti-pumping relay AC110V 06-63 32 06-32 IANS ANTI220 Anti-pumping relay AC220V 06-63 32 06-32 IANS APR-DP APR panel display unit 06-63 32 06-32 IANS AUX-SW Auxiliary contact 1a1b of auxiliary switch 06-32 IANS AS/32F Auxiliary switch unit for fixed type 06-32 IANS AS/32D Auxiliary switch unit for draw-out type 06-32 IANS CJ Control circuit unit both male and female part 06-63 IANS CT016E Current transformer 160/0. 1EA 32-40 32 32 IANS CT440E Current transformer 4000/0. 1EA 06-16 32 06-16 IANS CT080E Current transformer 800/0. 1EA 06-16 IANS CT032E Current transformer 320/0. isolated: 1C 06-63 32 06-32 AT IANS PS-U Position switch inserted: 1C 06-63 32 06-32 AU IANS PS-V Position switch isolated: 1C 06-63 32 06-32 AV IANS WR-INSERT. test: 1C 06-63 32 06-32 AQ IANS PSC2 Position switch conn.2A. 1EA 12-16 32 12-16 IANS CT116E Current transformer 1600/0.2A.2A. 1EA 20-32 32 20-32 IANS CT225E Current transformer 2500/0.2A. for 1 pole 20-32 20-32 32 06-16 06-16 63 .: 2C 06-63 32 06-32 AR IANS PST2 Position switch test: 2C 06-63 32 06-32 AS IANS PS-T Position switch inserted: 1C.2A. 1EA 06-16 IANS CT063E Current transformer 630/0. 1EA 40-63 IANS CT550E Current transformer 5000/0.2A.2A. 1EA 16-63 32 16-32 IANS CT220E Current transformer 2000/0. 1250A 12 12 IANS FC16 Fix arcing contact 1EA. 630A 06 06 IANS IC08E Isolating contact 1EA. 1000A 10 10 IANS IC12E Isolating contact 1EA. AC380V 06-63 32 06-32 IANS UVT-CON4 UVT controller Time delay type. 2000A 20 20 IANS IC25E Isolating contact 1EA. 800A 08 08 IANS FC10 Fix arcing contact 1EA. 2000A 20 20 IANS FC25 Fix arcing contact 1EA. DC200V 06-63 32 06-32 IANS UVT/COIL UVT coil 06-32 IANS UVT/COIL6 UVT coil 40-63 ACB order code Category 25 32 32 25 32 32 63 06-32 32 ACB A9 06-32 32 06-32 32 06-32 32 06-32 32 06-32 32 06-32 06-32 32 | 65 | . 800A 08 08 IANS IC10E Isolating contact 1EA. 630A 06 06 IANS FC08 Fix arcing contact 1EA. 1250A 12 12 IANS IC16E Isolating contact 1EA. AC440V 06-63 32 06-32 IANS UVT-CON5 UVT controller Instantaneous type. 3200A 32 IANS IC40E Isolating contact 1EA. AC220V 06-63 32 06-32 IANS UVT-CON3 UVT controller Time delay type. 1600A 16 16 IANS IC20E Isolating contact 1EA. 1000A 10 10 IANS FC12 Fix arcing contact 1EA. 2500A 25 IANS FC32 Fix arcing contact 1EA. HiAH & HiAS Type Description Code Name Applied ACB Specification HiAN HiAH 40-63 32 HiAS IANS DI63P DI unit Arc chamber. AC110V 06-63 32 06-32 IANS UVT-CON2 UVT controller Time delay type. 1600A 16 16 IANS FC20 Fix arcing contact 1EA. 4000A 40 IANS IC50E Isolating contact 1EA. for 1 pole IANS FC06 Fix arcing contact 1EA. 6300A IANS HANDLE Draw-in/out handle 06-32 IANS HANDLE5 Draw-in/out handle 40-63 IANS L1 LRC unit AC110V 06-32 IANS L16 LRC unit AC110V 40-63 IANS L2 LRC unit AC220V 06-32 IANS L26 LRC unit AC220V 40-63 IANS L5 LRC unit DC110V 06-32 IANS L56 LRC unit DC110V 40-63 IANS L6 LRC unit DC220V 06-32 IANS L66 LRC unit DC220V 40-63 IANS L7 LRC unit DC24V 06-32 IANS L76 LRC unit DC24V 40-63 IANS L8 LRC unit DC48V 06-32 IANS L86 LRC unit DC48V 40-63 32 IANS MHT Magnetic holing trigger 06-63 32 06-32 IANS UVT-CON1 UVT controller Time delay type.HiAN. 3200A 32 IANS IC06E Isolating contact 1EA. 5000A 50 IANS IC63E Isolating contact 1EA. 2500A 25 IANS IC32E Isolating contact 1EA. DC100V 06-63 32 06-32 IANS UVT-CON6 UVT controller Instantaneous type. UVT Trip 12 IANS-SP12 With Motor. UVT Trip ● HiAN08 HiAN12 HiAN16 HiAN20 HiAN25 HiAN32 HiAN40 HiAN50 HiAN63 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● . UVT Trip 15 IANS-SP15 With Motor. SHT Trip 35 IANS-SP35 With Motor. APR. APR. UVT Trip 16 IANS-SP16 With Motor. SHT Trip 33 IANS-SP33 With Motor. UVT Trip 19 IANS-SP19 With Motor. SHT Trip 29 IANS-SP29 With Motor. SHT Trip 24 IANS-SP24 With Motor. UVT Trip 39 IANS-SP39 With Motor. SHT Trip 34 IANS-SP34 With Motor. APR. APR. APR. APR. UVT Trip 3 IANS-SP03 With Motor. APR. APR. APR. APR. APR. UVT Trip ● 8 IANS-SP08 With Motor. UVT Trip 14 IANS-SP14 With Motor.Air Circuit Breaker Order Information Spare parts for marine applications (HiAN type only) | 66 | Applied ACB No Code Specification 1 IANS-SP01 With Motor. APR. SHT Trip 28 IANS-SP28 With Motor. APR. SHT Trip 22 IANS-SP22 With Motor. SHT Trip 32 IANS-SP32 With Motor. APR. UVT Trip 7 IANS-SP07 With Motor. APR. UVT Trip 38 IANS-SP38 With Motor. UVT Trip 4 IANS-SP04 With Motor. SHT Trip 23 IANS-SP23 With Motor. UVT Trip 10 IANS-SP10 With Motor. SHT Trip ● 27 IANS-SP27 With Motor. UVT Trip 13 IANS-SP13 With Motor. APR. APR. APR. APR. APR. APR. SHT Trip 30 IANS-SP30 With Motor. APR. SHT Trip 21 IANS-SP21 With Motor. APR. APR. APR. SHT Trip ● 26 IANS-SP26 With Motor. UVT Trip ● 42 IANS-SP42 With Motor. SHT Trip 31 IANS-SP31 With Motor. SHT Trip 20 IANS-SP20 With Motor. APR. UVT Trip 40 IANS-SP40 With Motor. APR. SHT Trip ● 36 IANS-SP36 With Motor. APR. APR. APR. APR. UVT Trip ● 9 IANS-SP09 With Motor. UVT Trip 11 IANS-SP11 With Motor. APR. SHT Trip ● 37 IANS-SP37 With Motor. UVT Trip 6 IANS-SP06 With Motor. APR. APR. APR. APR. UVT Trip 2 IANS-SP02 With Motor. UVT Trip 17 IANS-SP17 With Motor. APR. APR. UVT Trip 5 IANS-SP05 With Motor. UVT Trip 41 IANS-SP41 With Motor. APR. SHT Trip 25 IANS-SP25 With Motor. UVT Trip 18 IANS-SP18 With Motor. APR. APR. APR. HiAN. refer to the installation instructions in the catalogue and instruction manual.600 feet) ▶ Atmosphere Excessive water vapor. Sudden change in temperature. or icing must not occur. ▶ Installation conditions When installing the HiAN series air circuit breaker. and provides IP20 protection. which is quite harmful to the breaker insulation. ▶ IP protection Standard: IP20 A door flange can be used as a decoration panel that covers the cutout on the switchboard panel. ▶ Transportation conditions Never enter the area under the air circuit breaker when it is lifted or suspended using a lifter or chain block. Store the breaker in a clean place free of corrosive gases. condensation. smoke. HiAH & HiAS Type Operation Environment ▶ Ambient temperature -5℃ to +40℃ The average temperature for 24hours must not exceed 35℃ ▶ Relative humidity 45% to 85% ▶ Altitude Below 2000m (6. dirt and dust. ▶ Storage Store the breaker in a dry indoor location to prevent condensation due to a sudden change in temperature. oil vapor. The air circuit breaker may suddenly drop. | 67 | . dust or corrosive gases must not exist. With door flange: IP41 IP41 is possible with the use of door flange in switchboard door. Minami Senba. Zip: 212212.. 3215-7159 Fax: 81-3-3211-2093 Osaka I-Room 5th Fl. 5767 Fax: 81-6-6261-5818 Dubai Unit 205. 5-17 Hammersmith Grove. U. 4.. 2-4-8. 0212 Fax: 86-511-8842-0668. Bulgaria Tel: 359-2-803-3200 Fax: 359-2-803-3203 Yangzhong No. Suite 170. London. Sofia 41. Dong-gu. Florida 32817.HHIS-WC-LE-B42-03. Korea Tel: 82-2-746-7510. Jongno-gu. 2009. Jeonha-dong. Sheikh Zayed Road. Tel: 1-407-249-7350 Fax: 1-407-275-4940 New Jersey 300 Sylvan Avenue.4 Designed by MERMONT Head Office 1. Jiangsu.A. Chiyoda-gu. Japan Tel: 81-3-3212-2076. Seoul. Nagahori-Plaza Bldg. Tel: 1-201-816-0286 Fax: 1-201-816-4083 London 2nd Floor. NJ 07632. UK Tel: 44-20-8741-0501 Fax: 44-20-8741-5620 Tokyo 8th Fl. . Yurakucho Denki Bldg. Level 2. Japan. Gye-dong. Burj Dubai Square Building No. W6 0LG. Xinba Scientific and Technologic Zone.S. Korea Tel: 82-52-202-8101~8 Fax: 82-52-202-8100 Seoul (Sales & Marketing) 140-2. Chuo-Ku. Ulsan. P. U. Yangzhong. 100-0006. Orlando. 0231 ※Recyled paper used for environmental protection. Rojen Blvd. Englewood Cliffs.C. China Tel: 86-511-8842-0666. P. Tokyo.A. 7589 Fax: 82-2-746-7647 Orlando 3452 Lake Lynda Drive.Box 252458 Tel: 971-4-425-7995 Fax: 971-4-425-7996 Sofia 1271. 542-0081 Tel: 81-6-6261-5766.1-7-1. The Triangle.O.S.R. Yuraku-cho. Osaka. 9 Xiandai Road.
Copyright © 2024 DOKUMEN.SITE Inc.