HFS-R-146[1627]

March 28, 2018 | Author: MoriyasuNguyen | Category: Duct (Flow), Building Engineering, Mechanical Engineering, Nature


Comments



Description

Fire Dampers &Smoke Dampers H Series HFS, IBD, IBD - FS & LR. HFS Fire and Leakage Rated Smoke Damper. 322 - 325H Multileaf Blade Design. Range of Electrical On/Off, Spring Return and Pneumatic Actuators. IBD Interlocking Curtain Blade Fire Damper. 307 - 321H HFS & IBD Vertical and Horizontal Mounting. IBD - FS ‘Fire Seal’ Fire and Leakage Rated Damper. HFS, IBD & IBD - FS. Roll Formed Blades and Frame. HFS, IBD & IBD - FS. Universal Mounting Sleeve and Angles. IBD & IBD - FS. IBD & IBD - FS. 329 - 340H 314 - 317, 323, 334 - 336H ‘Safe Test’ Test Latch Fitted as Standard Electro Thermal Resettable Link Option, (Allows remote activation via Smoke Detectors, or Alarm System). LR Low Heat Radiation Fire/Smoke/Control Damper. 326 - 328H Innovative Low Radiation, Low Leakage, Insulated Single Damper Blade. Mounting Flanges, Pre-Insulated Sleeve and Air Balancing Damper. IBD - FS & LR. Vertical (Wall Mounting Only). All Products 4 Hour Fire Rated, (subject to wall/floor thickness and construction). 71 Degrees C Fusible Link (Standard). Ordering Key and Specification 321, 325, 328 & 340H 307H Fire & Smoke Dampers Series IBD – Fire Dampers Holyoake Curtain-type fire dampers are designed to maintain the integrity of the fire resistance of a wall, or floor, in which a hole has been formed to permit the passage of air, ducted or otherwise, to enable an air distribution system to function. The arrangement of interlocking blades mounted in a guide channel frame, minimizes space requirements and facilitates ease of installation in ductwork. Fire Rating: All Holyoake Series IBD units carry up to a 4 HOUR rating to AS 1530.4 as determined by the following testing Authority. For the purposes of the Australian and New Zealand Building Code they have an FRL/FRR of – / 240 / – . UÊBRANZ Assessment Report Certificate No.1 IBD Damper mounted in a concrete wall, or floor. (Certified for 240 minute fire rating). UÊBRANZ Model IBD-B-V Illustrated. Mounting Sleeve Omitted for Clarity, refer to Pages 313H - 317H for details. Fire Test Certificate No. FTC 392 IBD Damper mounted in a plasterboard wall. (Certified for 30 or 60 minute fire rating). (Certificates are available upon request). Standard Construction Frame: 110 mm x 1.2 mm galvanised steel, roll formed guide channel. Blades: 70 mm x 1.0 mm galvanised steel, roll formed inter-locking profile. Springs: Blade End: stainless steel. Retraction: stainless steel. Note: Horizontal dampers with a duct ‘B’ dimension of less than 180 mm have all blades fitted with end springs only. Above 180 mm constant force springs only are fitted. All vertical dampers have the bottom blade only fitted with end springs. Style-B Alternate Activation: Electro-Thermal Resettable Link This device can be activated by smoke detectors of compatible design, (Supply and fit by others). By definition, a fire damper provides an effective barrier to the passage of fire and products of combustion, but when its operation is initiated by the detection of smoke, or other products of combustion it may then be termed “smoke damper”. The difference between a fire damper and a smoke damper is not a physical one, but is in the method of initiating the operation. (AS 1682.1-1990). Series IBD fire dampers must be installed in sleeves (refer to Pages 313H - 317H). These sleeve assemblies are available, please consult the sales office. Stainless Steel: Construction in stainless steel is available for both IBD and mounting sleeves. Style-C Style-CR H B (Duct) B A Vertical or horizontal, but in all cases the blades must be horizontal. Mounting Sleeves: Fusible Links: ‘Safe Test’ Test latch Model IBD-TL fitted as standard, complete with 71º C Fusible Link. See page 318H for more details. (Other ratings available on request). Please contact your local Holyoake branch. Duct Connection Style-A Mounting: H B (Duct) B H (Duct) H A (Duct) A + 64 B (Duct) D + 64 A (Duct) A + 64 A Style-CO Single Section Maximum Dimensions DUCT CONNECTION STYLE Alternative Max. Dimension Combinations Vertical Horizontal A B C CR A B A B A B 838 1219 838 1016 1828 762 965 762 838 1219 838 1016 1600 654 835 654 774 1155 774 952 1568 622 803 622 Mounting Sleeves omitted for clarity. CO B A B 774 774 1155 774 952 1568 622 803 622 Notes Horizontal Vertical 1. In specifying a fire damper the width should always be stated first and the height second. 2. Nominal dimensions are opening sizes and allow clearance for insertion into mounting sleeve: 6 mm Duct Connection Style A & B. 3 mm Duct Connection Style C, CR & CO. Where this allowance is not required specify “exact size”. 308H © Holyoake Air Management Solutions – 2013 refer to Pages 313H .refer to Pages 313H . blade stack located within air stream.317H for details. spring loaded initial movement. Dimension ‘B’ From To 63 15* 64 183 30* 184 303 42* DUCT CONNECTION STYLE ‘A’ (Single Section) 304 424 544 664 784 904 1024 1144 1264 1384 1504 1624 1744 423 543 663 783 903 1023 1143 1263 1383 1503 1623 1743 1828 54* 66* 78* 90 102 114 126 138 150 162 174 186 198 From To 83 29* 824 883 129 84 143 29* 884 943 129 144 178 54* 944 1003 129 DUCT CONNECTION STYLE ‘B’ (Single Section) 179 239 299 359 394 454 238 298 358 393 453 513 54* 54* 54* 79* 79* 79* 1004 1039 1099 1159 1219 1254 1038 1098 1158 1218 1253 1313 154 154 154 154 179 179 Dimension ‘X’ Dimension ‘B’ Dimension ‘H’ = B + Dimension ‘B’ Dimension ‘H’ = B + From To 514 573 79* 1314 1373 179 574 608 104 1374 1433 179 609 668 104 1434 1468 204 669 728 104 1469 1528 204 729 788 104 1529 1588 204 789 823 129 1589 1600 204 * Minimum of 85 mm when fitted with IBD . refer to Page 318H. gravity operated. even under relatively low pressure differential conditions. gravity operated. vertical (wall) mounting damper. 309H . H IBD-A-V A Mounting Sleeve omitted for clarity . blade stack located out of air stream. Model IBD-A-V (Multiple) Model: IBD-A-V (multiple) X See above for details on individual IBD-A-V dampers IBD-A-V IBD-A-V IBD-A-V B IBD-A-V IBD-A-V IBD-A-V A Model IBD-B-V (Multiple) Model: IBD-B-V (multiple) Where opening is larger than maximum single section size. IBD-B-V IBD-B-V IBD-B-V B IBD-A-V IBD-A-V Maximum multiple unit module for vertical dampers is 3 wide by 2 high single sections as shown. would consist of ‘B’ type units in the top row only and ‘A’ type elsewhere. vertical (wall) mounting damper. Style ‘B’ assemblies where more than one unit high.Fire Dampers – Series IBD Assembly and Dimensional Information (A & B Dimensions allow 6 mm clearance for mounting sleeve of nominated size) X Model: IBD-A-V B Interlocking blade. spring loaded initial movement.ETR. Adequate fire rated bracing must be provided by the installer to prevent collapse of multiple unit assemblies when closed. or A 1219 x B 654 mm (Single Section). Air Flow Either Way Minimum size A 100 x B 83 mm. or A 1219 x B 762 mm (Single Section). Multiple assemblies are shipped in sections for field assembly. B IBD-B-V 77 110 A Mounting Sleeve omitted for clarity . Maximum size combinations: A 838 x B 1828.317H for details. an assembly of equal size single section dampers is used. IBD-A-V Air Flow Either Way 77 110 189 150 Minimum size A 100 x B 63 mm. Maximum size combinations: A 838 x B 1600. A Model: IBD-B-V H Interlocking blade. Model: IBD-B-H Interlocking blade. Minimum size A 100 x B 35 mm. *Where dimension ‘B’ exceeds 180 mm. horizontal (floor) mounting fire damper. Model IBD-B-H (Multiple) Model IBD-A-H (Multiple) Where opening is larger than maximum single section size.ETR.Fire & Smoke Dampers Series IBD – Fire Dampers Assembly and Dimensional Information Model: IBD-A-H B Interlocking blade. which drive the curtain to the closed position. blade stack located within air stream. thus improving access and minimising air flow interference. B B Mounting Sleeve omitted for clarity. Where dimension ‘B’ is less than 180 mm. A B A IBD-A-H IBD-B-H Minimum size A 100 x B 70 mm. Multiple assemblies are shipped in sections for field assembly. Model: IBD-A-H (multiple) Model: IBD-B-H (multiple) (A & B Dimensions allow 6mm clearance for duct of nominated size).* spring loaded for complete travel.317H for details. all blades are fitted with “omega” springs at blade ends. or A 1016 x B 762 mm (Single Section). Maximum size combinations:A 838 x B 835. Dimension ‘B’ From To 70 26* 71 100 42* 101 150 56* DUCT CONNECTION STYLE ‘A’ (Single Section) 151 181 244 364 484 604 180 243 363 483 603 723 70* 40* 52* 64* 76* 88 724 843 100 844 965 112 From To 35 54* 36 85 54* 86 110 54* DUCT CONNECTION STYLE ‘B’ (Single Section) 111 161 181 239 299 359 160 180 238 298 358 393 54* 54* 54* 54* 54* 79* 394 453 79* 454 513 79* Dimension ‘X’ Dimension ‘B’ Dimension ‘H’ = B + 310H * Minimum of 85 mm when fitted with IBD . Blade stacks for assemblies two sections across the ‘B’ dimension are normally installed as illustrated. blade stack located out of air stream. refer to Page 318H. horizontal (floor) mounting fire damper. with blade stacks outermost. two constant force springs anchored to the frame and attached to the last blade draw the blade curtain closed.* spring loaded for complete travel. an assembly of equal size single section dampers is used. refer to Pages 313H . 514 573 79* 574 608 104 609 668 104 669 728 104 729 788 104 789 823 129 824 835 129 © Holyoake Air Management Solutions – 2013 . 150 189 110 77 110 77 Air Flow Either Way H Mounting Sleeve omitted for clarity. Air Flow Either Way X Spring arrangement similar to IBD-A-H. IBD-A-H IBD-B-H IBD-A-H IBD-B-H A A IBD-A-H IBD-B-H IBD-A-H IBD-B-H Maximum multiple unit module for horizontal dampers is 2 wide and 2 high single sections as shown.317H for details. or A 1016 x B 654 mm (Single Section). Maximum size combinations:A 838 x B 965. refer to Pages 313H . spring loaded initial movement. vertical (wall) mounting damper. refer to Pages 313H . fitted with enclosure plates and oval spigots to suit duct connections. vertical (wall) mounting damper. 311H . IBD-CR-V MULTIPLE ASSEMBLY B (Duct) H 32 A or B+ 64 Mounting Sleeves omitted for clarity. gravity operated. spring loaded initial movement. Air Flow Either Way H B (Duct) IBD-CO-V 32 50 77 110 A (Duct) A + 64 50 32 32 A or B (Duct) Typical Multiple Assembly Where opening is larger than maximum single section size. gravity operated. Air Flow Either Way H B (Duct) IBD-CR-V 32 50 77 110 B + 64 50 Model: IBD-CO-V Interlocking blade located out of airstream. spring loaded initial movement. fitted with enclosure plates and round spigots to suit duct connections.Fire Dampers – Series IBD Assembly and Dimensional Information Model: IBD-C-V Interlocking blade located out of airstream. an assembly of equal size single section dampers is used. Where ‘H’ requires more than one section. refer to Page 318H. CR & CO (Single Section) 147 207 267 327 362 422 482 206 266 326 361 421 481 541 86* 86* 86* 111 111 111 111 972 1007 1067 1127 1187 1222 1282 1006 1066 1126 1186 1221 1281 1341 186 186 186 186 211 211 211 542 576 136 1342 1401 211 577 636 136 1402 1436 236 637 696 136 1437 1496 236 697 756 136 1497 1556 236 757 791 161 1557 1568 236 * Minimum head height with IBD . A & B Dimensions allow 3 mm clearance for duct of nominated size Dimension ‘B’ From To Dimension ‘H’ = B + Dimension ‘B’ Dimension ‘H’ = B + From To 51 61* 792 851 161 52 111 61* 852 911 161 112 146 86* 912 971 161 DUCT CONNECTION STYLE C. fitted with enclosure plates and square. Air Flow Either Way H B (Duct) IBD-C-V 32 40 77 110 A (Duct) A + 64 40 Model: IBD-CR-V Interlocking blade located out of airstream. The extent of this obstruction may be determined by dimension ‘X’ on Model IBD-A-V. vertical (wall) mounting damper. the blade stack for the lower section will be in the air stream.ETR is 85 mm. gravity operated.317H for details. or rectangular spigots to suit duct connections. of the appropriate size. Horizontal. *50 mm for IBD-CR-H or IBD-CO-H. or D are less than 148 mm. & CO’ (Single Section) 129 149 207 267 327 362 422 482 148 206 266 326 361 421 481 541 86 86 86 111 111 111 111 86 542 576 136 577 637 636 + 696 136 136 697 756 136 757 792 791* 803* 161 161 * Maximum Single Section for DuctConnection Style CR is 774 mm Diameter. *spring loaded for complete travel. the blade stacks are located out of the air stream on opposite sides of the opening. horizontal (floor) mounting fire damper. all blades are fitted with “omega” springs at blade ends. A + 64 A (Duct) * Where B. horizontal (floor) mounting fire damper.Fire & Smoke Dampers Series IBD – Fire Dampers Assembly and Dimensional Information Typical Section Styles C. horizontal (floor) mounting fire damper. IBD-C-H Air Flow Either Way 40* 77110 40* 32 Model: IBD-C-H Interlocking blade located out of airstream. fitted with enclosure plates and round spigots to suit duct connections. Where B. H B (Duct) A + 64 A (Duct) IBD-C-H 32 H B (Duct) Model: IBD-CR-H Interlocking blade located out of airstream. CR. which drive the curtain to the closed position. CR & CO. 312H © Holyoake Air Management Solutions – 2013 . *spring loaded for complete travel. A & B Dimensions allow 3 mm clearance for duct of nominated size. two constant force springs anchored to the frame and attached to the last blade draw the blade curtain closed. fitted with enclosure plates and oval spigots to suit duct connections. Where ‘H’ requires two sections. B+ 64 IBD-CR-H 32 H B (Duct) Model: IBD-CO-H Interlocking blade located out of airstream. or rectangular spigots to suit duct connections. Dimension ‘B’ + Dimension ‘H’ = B + From To 53 86 54 78 86 79 128 86 Duct Connection Style ‘C. or D dimension exceeds 148 mm. + Dimension B is a Maximum of 622 mm if Dimension A = 774 . an assembly of equal size single section dampers is used. fitted with enclosure plates and square. *spring loaded for complete travel. IBD-CO-H H B (Duct) A or B + 64 IBD-CR-H A or B (Duct) Typical Multiple Assembly MULTIPLE ASSEMBLY Where opening is larger than maximum single section size.952 mm. 2 Air flow may be from either direction for Holyoake Series IBD. The casing shall completely penetrate the fire barrier and be retained: (VIII) All Holyoake IBD type fire dampers must be sleeve mounted. Slip Joints. which allows galvanised steel with a coating class not less than Z275.1990. with 6 mm bolts and nuts. 10 steel screws. 6 Retaining flanges must be of minimum thickness 2. 7 shall be butted against the face of the fire barrier and fixed to the fire damper casing.6. minimum sleeve thickness is 0. It draws upon SMACNA fire. They are mandatory on all four sides. 3 While damper size influences acceptable velocities (i. Fixings should be finger tight (to allow movement for thermal expansion).7 See details on following pages.55 mm. Vertical in wall Vertical in wall This is the correct position Vertical in wall (X) Ensure damper is square and free from racking. Prototypes were tested with a High Temperature Loose Wool. If velocities are expected to exceed this.5 mm for face area > 2 m2. Mounting flanges 5. Australian Standards Association allow that the combination of casing and sleeve in this case satisfies this requirement.e. 12 mm welds. does not dislodge the fire damper. both width and height. 313H . Proprietary Duct Flange Systems. (I) (b) on the accessible side by means of one mounting flange only. but need not be welded to form a frame. 7 Materials for sleeves and retaining flanges must comply with AS 1682. or 2. the blade and pivots must be fully contained within the penetrated element and within the casing (AS 1682. Notes 1 AS 1682. 6. such as high temperature mineral wool. 5 SMACNA requires the damper and retaining flanges to be secured to the sleeve. i. They must be installed fully open. Holyoake Industries suggests a maximum of 10 m/s on vertical gravity dampers.2 . or exceed 50% of the flange face width. or horizontally. e.Fire Dampers – Series IBD Fire Damper Installation The following installation method and diagrams (shown on the next page) are presented as the method by which Holyoake fire dampers must be installed. etc.e. both vertical and horizontal. Part 2. and greater for larger sizes. or (IX) Series IBD vertical (wall) mounted fire dampers must not be installed either with blades vertical (on end). third edition.1 . may be accepted for this purpose. fusing at not less than 1000ºC. (IV) Clearance between sleeve and penetration should be packed with compressible.1 . or affect its performance.g.1 . 1986. (V) Access doors.1990 requires the casing to be no less than 1. that there are no obstructions in the centre track. and air velocities3 do not exceed the damper’s limit (10 m/s). and is intended to meet the requirements of Australian Standard 1682.6 mm in thickness. or No.6 mm for the smallest duct size. it is suggested that spring closure (type H) dampers be specified. Holyoake sleeves are a minimum thickness of 0. (XI) For Special Applications and Installation Methods. and that it is installed in accordance with the “this way up” arrow on every damper. in no case should total clearance be less than the tested prototype (12 x 2 = 24).e.5. (Optional fixing screws can be provided). with double nut (lock nut).0 mm for face area < 2 m2 (AS 1682. but locked. (II) The fire damper shall be installed so that the airflow2 does not impede its closure. smoke and radiation damper installation guide for HVAC systems. to test and reset release mechanisms and for inspection. i. 1990. please contact your local Holyoake Branch. (a) on both sides by means of mounting flanges in such a manner that it can expand in a fire without distorting the blades in a closed position. However. The width of the angle section of the flange shall be not less than twice the clearance between the fire damper body and the penetration.1990).1990).45mm which augments the roll-formed section to provide a total of 1. (III) The method of attachment of ductwork to the fire damper must be such that any deformation. even for vertical mounting. which can be fixed to the fire damper and to the fire barrier through oversized holes and penny washers. This is best achieved by the use of breakaway joints which will allow damaged ductwork to fall away. must be provided for duct entry. (VI) When installed and closed. or collapse of the ductwork in a fire. Pressure differential across the closed damper should not exceed 750 Pa. non-combustable4 materials and generally be such that the hole size may be no less than overall sleeve size + 1% + 10 mm. 4 Material capable of resisting high temperatures. or removable pressed panels. with the blade stack below the opening. 4. In keeping with SMACNA recommendations.7 mm steel rivets. (VII) Fire dampers may not be used as control dampers. the larger the damper the lower the velocity). Duct Connections Style ‘C’. (refer to notes on previous page). ‘SafeTest’ Test latch. Plasterboard packer all round (as per wall lining). Plasterboard packer not required if double layer wall linings used. Keep track clear of fastenings and other obstructions. Sleeve (VIII on page 313H). Installation in a Plasterboard Wall. Plasterboard Wall. Duct. attached to wall. (refer to notes on previous page). Plasterboard as per wall lining. Duct Connections ‘S’ Cleat . Typical Fire Damper Installation Various Styles Fixing (Note 7 on page 313H). Breakaway Joint (III on page 313H). Clearance & Packing (IV on page 313H). screwed at the corners and to the vertical studs. Sleeve (VIII on page 313H). * = Wall opening to be lined with the same quantity and thickness of plasterboard. Fire rated mastic sealant. Timber or Steel stud framing the opening all round. Fixing to sleeve (Note 5 on page 313H). Duct Connections Style ‘A’. Damper. Fire & Smoke Dampers Duct Connections Style CR & CO. Steel retaining angles not fixed to wall. as per wall lining. Keep track clear of fastenings and other obstructions. 314H © Holyoake Air Management Solutions – 2013 . Mounting Angles & Fixing. Clearance & Packing (IV on page 313H). 300 Typ. Joining of multiple sections. ‘S’ Cleat (III on page 313H). Joining of Multiple Sections. Attached to stud*.Series IBD – Fire Dampers Fire Damper Installation Installation in a Masonry Wall.Typical Style ‘B’. 50 Typ. Contact your local Holyoake branch for details. Refer to Pages 313H . Note Standard Switches are not fire rated. factory fitted.317H for full sleeve information. 2. Reset and Release Microswitches Optional Release and/or Reset Microswitches are available. Above details are intended as a guide for field installation of sleeves. Duct attachment method for the IBD Type ‘B’ in Sleeve NC NO C Damper Open (Blades Stacked) Damper Closed (Blades Released) Top Switch (Blade Stack) NC C NO Brown Green 2 Blue NC C NO NO Blue 1 2 1 Green 4 NC C 5 NO E Brown 1 Green 4 Blue ‘S’ Cleat 3 Bottom Switch Brown Blue Brown Green C 3 Bottom Switch NC Duct Sealer Top Switch (Blade Stack) 1 5 Sleeve Connecting Duct E NC NO C Notes 1. 315H . page 309H.Fire Dampers – Series IBD Installation Details and Sleeve Mounting Dimensions Model: IBD-B -V Model: IBD-A-V H (x A) B (x A) B (x A) 150 Max 6 150 Max 6 150 Max 6 150 Max 6 Model: IBD-A-H Model: IBD-B -H 150 Max 6 150 Max 6 150 Max 6 150 Max 6 B (x A) B (x A) H (x A) For ‘H’ dimension refer to table. Guide Product Weights IBD Curtain Fire Dampers IBD-A-V 200 x 200 IBD-A-V 600 x 400 (Inc Sleeve) Approximate Weight in Kg 2 16.64 IBD-CR-V 150 Diameter IBD-CR-V 200 Diameter IBD-CR-V 250 Diameter IBD-CR-V 450 Diameter IBD-CR-V 400 Diameter (Inc Sleeve) 3.Series IBD – Fire Dampers Installation Details and Sleeve Mounting Dimensions Model: IBD-C-V Model: IBD-CR-V Fire & Smoke Dampers (IBD-CO-V Similar) H (x B + 64) H (x A + 64) B B 150 Max 6 150 Max 6 150 Max 6 150 Max 6 Model: IBD-CR-H Model: IBD-C-H (IBD-CO-H Similar) 150 Max 6 150 Max 6 150 Max 6 150 Max 6 B H (x A + 64) BD H (x D B + 64) For ‘H’ dimension refer to table on page 311H.54 8.5 12.02 © Holyoake Air Management Solutions – 2013 .43 6.45 23.03 16.5 4.26 19.12 10.1 4.08 5.5 16 16.317H for full sleeve information.7 11.5 Notes 1. 316H IBD-CR-H IBD-CR-H IBD-CR-H IBD-CR-H 150 Diameter 200 Diameter 300 Diameter 350 Diameter 3.62 IBD-A-H 580 x 480 IBD-A-H 1000 x 680 8.7 4. 2.4 IBD-B-V 250 x 250 IBD-B-V 206 x 500 IBD-B-V 760 x 560 IBD-B-V 1050 x 700 IBD-B-V 350 x 350 (Inc Sleeve) IBD-B-V 400 x 375 (Inc Sleeve) IBD-B-V 500 x 350 (Inc Sleeve) 3. Refer to Pages 313H . Above details are intended as a guide for field installation of sleeves.22 IBD-B-H 600 x 600 11. One set is fixed on one end of the sleeve and the other set is supplied loose. f Type ‘B’ damper sleeves are fitted with a duct bridging piece. This then complies with AS 1682. See Installation (IV on page 313H). g An extended damper sleeve is available for wall depths 291 – 690 mm.1371 1372 . Parts 1 & 2. d Optional ‘S’ cleats on all edges (Typical Breakaway Joint). for final fixing of these to the sleeve. Optional Extended Sleeve 291 mm. See Installation (IV on page 313H). by others. if slip joint or ‘S’ cleat is used. (x4 per side. h Casing sleeve may only be extended 150 mm from the face of the wall on each side. Wall or Floor 6 C CR CO Width A-3 A-3 A + 67 B + 67 A + 67 Height B-3 H+3 H+3 H+3 H+3 150 Max. unless specified at 80 mm.55 0. 1990. Optional Extended Sleeve 690 mm Typical Assembly . Or Floor Thickness: Factory Fixed Retaining Flanges+ * Standard length. They are of a standard length (450 mm). + May be supplied loose due to handling considerations. 40 450* H (ID) Loose Retaining Flanges (Note: Both sets may be provided loose.95 100 Min. Wall or Floor 40 If in excess of these dimensions sleeve should be trimmed back to the appropriate lengths. Style 4 40 690 Max. 317H . then attached to the damper frame on all four sides.Selection Data – Series IBD Universal Mounting Sleeve IBD-MSU (Factory Furnished) Typical IBD Installation 60 Holyoake Fire Damper Sleeves Model IBD-MSU fire damper mounting sleeves are constructed to meet the requirements of AS 1682. (Typical Breakaway Joint – refer to Section K Accessories). or 80 mm each side if ‘Breakaway’ flange is fitted. optional extended length sleeves are available upon request. Flanges 40 x 60 x 2 mm galvanised steel angle. 60 Typical Assembly . Field Fixed Angles 6 1 * 4 3 *This area within wall. or floor depth. However. Wall or Floor 6 150 Max. Factory Fitted Angles+ 0. Supplied only as part of a complete unit. W (ID) All factory sleeves are supplied fixed to the appropriate fire damper.55 0.300 301 . 2 60 B 28 Packing Material. 450 Standard. or floor depth. Specify alternative if required. 291 Min. Maximum Dimensions per Side Sleeve Thickness 0 . c All damper sleeves come with raw edges.1990 (refer also page 313H. Or Floor Thickness: 60 Standard Sleeve 100 mm. or ‘no bolt corner clips’ for Fire Damper Breakaway Joints. or 35 mm Breakaway flange on all edges. Mounting angles are supplied. Minimum Wall.Standard Damper Sleeve (B Type Damper Illustrated) Material: Galvanised Steel Type Z275. (Optional PVC cleats are available). x 2) Construction: Sleeves are corner lapped and spot-welded. Maximum Wall. or Extended Sleeve A 2 290 Max.75 0.Optional Extended Damper Sleeve (A Type Damper Illustrated) Factory Fitted Angles+ 80 Max. Wall or Floor 850 Max 28 Packing Material. 6 Field Fixed Angles 1 5 3 * *This area within wall. on site.762 763 . Note: Factory Fitted Mounting Angles are positioned 150 mm from the end of the sleeve. Do NOT use bolts. Parts 1 & 2 . Standard Sleeve 290 mm. due to handling and transport considerations). sufficient for all wall thicknesses up to 290 mm. to form a rigid assembly. e Optional 25. (specify length required when ordering).1828 80 Max. Damper Installation and Notes). when the latch is released. Replace the duct access door. 7. In the event of damage occurring during transit. Replace the locking pin in the latch. are available with optional Electro Thermal Resettable Link mechanisms. Reload the curtain and swing the fusible link back into place in the latch. To ensure the Life and Property saving function for which they are designed. track obstruction. lift both latch levers and remove fusible link. reach in and remove the locking pin from the nearest latch. 1. AS 1851 . swings clear and allows the curtain to close as if the link had parted under the influence of flame. (subject to minimum duct heights. 8. 2. 5. the curtain can be re-stacked and the same link clipped back into the latch. Check that the track is clear of any obstruction and keep hands clear. Blade Support/ Locating Bar Combined Electro/Thermal Release Type ‘A’ Minimum Duct Height for dampers fitted with Electro Thermal Resettable Links Duct Connection Style Minimum Duct Height A 210 B 150 C 150 CR 150 CO 150 MIN 85 Combined Electro/Thermal Release Blade Support/ Locating Bar 100 For testing purposes.Testing ‘Safe Test’ . and the curtain will rapidly close. where it is again ready to be released in the event of a fire. 6. Replace the duct access door. prior to retesting and handover. Electro Thermal Resettable Links Model: IBD-ETR All Holyoake IBD type fire dampers. or spring failure that may have occurred.Fire & Smoke Dampers Series IBD – Fire Dampers . 5. The Holyoake ‘Safe Test’ IBD-TL Test Latch. Support the blade pack. 24 V AC or DC Supply Electro Thermal Resettable Release. which. Remove locking pin from both sides. cleaning and removal of the obstacle. failure to function will reveal any warping. when released. Note: Take suitable safety precautions for Hand and Eye Protection. Lift the latch lever. Check that the locking pin is still in place on the other latch. 7. on site. 3. All IBD dampers are fitted with ‘Safe Test’ Test Latch links. Check that the track is clear of any obstruction and keep hands clear. see table below). rendering any fire damper ineffective. 8. Type ‘B’ 318H © Holyoake Air Management Solutions – 2013 . To Operate IBD Dampers below minimum heights shown.2012 (Section 13) requires that you annually test Fire Dampers. Reload the curtain and support the blade pack. Remove the duct access door (refer to Section K accessories section of this manual). all dampers below these heights will require removal of link and blades dropped manually. with integral 71 Degrees C Thermal Resettable Release. Release the blade pack and the curtain will rapidly close. so that the fusible link is retained by it. 3. Contact your local Holyoake branch for details. is a latching device with a specially made fusible link. This will require rectification. all fire dampers should be drop tested after installation.Test Latch Model IBD-TL O O O O O IBD-TL Safe and Simple Testing Method. 6. 4. 4. Remove the duct access door (refer to Section K accessories section of this manual). Max 30 Sec Release and 60 Sec Reset. Test and Reset in minutes. Each Holyoake Series IBD Fire Damper is mechanically tested before it is allowed to leave the factory. IBD-TL2 Latch Assy (Galvanised Steel) IBD-TL Fusible Link 71°C Locking Pin To Operate IBD Dampers 1. Using this access. or during installation. 2. whilst replacing the fusible link locating pins into both latches. After testing. Replace both locking pins. 2 kg/m3 air density.38 1.24 2.74 0.28 1.02 3.83 8. 200 150 125 V 30C 100 90 80 70 60 50 V 25C V 20C 40 V 15C 30 20 V 10C Static Pressure (Pa) 10 9 8 7 6 5 V 7.20 18.08 0.02 3. Find the Area Factor from the above table – enter duct height and width.50 7.99 5.27 82.45 6.0 2.29 3.36 2.88 2.30 12.60 1.60 2.10 3.8 1.1 .43 4.66 2. with ductwork upstream and downstream.20 1.35 2.5 2.80 42.15 4.60 13.41 1.80 9. pressure drop is 9 Pa.02 1.15 4.16 1. Determine Conversion Velocity (CV) by multiplying Area Factor by flow in m3/s (CV = Area Factor x m3/s).00 15.87 900 10.0 5.36 2.0C 4 V 3.33 2. CV = 11 x 0.88 0.60 4.74 2.11 1.20 11.17 1. Read pressure drop on left hand side of the chart.36 2.10 12.87 0.13 0.2 .25 1. 3.79 1. passing 11 m3/s.84 1.18 4.02 2.20 24.72 0.98 0.53 1.44 4.48 3.92 6.91 1.63 5.06 6.51 1.14 1.51 4.59 400 24.40 9.28 1. Performance Data – Series IBD Model: IBD-A-V. Note: Interpolations while not precise. 319H .6 .10 33. 2.60 14. ‘B’ (mm) 184 304 424 544 664 784 904 1024 1144 1264 1384 1504 1624 1744 100 200 55.23 3. or H Dim.4 .68 3.90 17.9.Fire Dampers.56 1. 2.61 3.80 0.5C 3 1 0.5 .61 0.00 1.96 0.01 0. From pressure drop chart.99 0.60 11.79 2. 2. EXAMPLE: Find the pressure drop across a 900 wide x 1504 high model IBD-A-V fire damper.07 0. Enter pressure drop chart with Area Factor and establish intersection with Conversion Velocity (CV) line just determined.24 1.80 11.66 1.42 5.70 3. 3. For pressure drop through an open IBD-A-V.51 6.STYLE A Dimension ‘A’ Width (mm) 500 600 700 800 19.69 1100 8.57 (All dimensions include 6 mm clearance total between outside of damper frame and inside of duct).00 15.5C V 5.84 1.02 2.97 0.00 5.75 2.20 21.19 1.62 3.10 5.09 0.88 0.00 1.02 1.97 1.37 1.73 1.90 8.70 55.16 2.07 1.83 0. the Area Factor is 0.90 29.38 1.29 2.01 4.69 1.31 3.79 0.66 0.42 3.0 10 15 20 30 40 50 70 100 Area Factor (From Table) Notes 1.3 .95 7.73 0.24 2.20 13.94 1.86 2.20 300 33.83 5.79 2.56 1.86 AREA FACTOR TABLE – DUCT CONNECTION . Ratings are based on dampers installed in accordance with details in this catalogue. From the table using interpolation.17 2. Static Pressure and Conversion Velocities are correct for 1.60 8.90 0.80 0.62 1200 7.0 4. 1.97 5.88 2.19 1.00 4.22 1.45 1.77 1000 9.34 1.52 2.0 1.50 14.67 0.80 28.5 3. or IBD-A-H fire damper use the following procedure: 1.53 2.00 19.01 4.9 = 10.87 2.47 3.32 1.98 4.45 1.61 1.75 1.63 5. are adequate for most calculations.53 2.0 8.90 17.90 8.58 1.18 6.08 0.0 6. 0 4.18 2.19 1.26 1.09 0.85 4.94 0.35 1.80 50.20 3. Ratings are based on dampers installed in accordance with details in this catalogue.67 1100 16. 2.41 1.35 1.14 1. with ductwork upstream and downstream.25 1.86 5.2 x 4. 2.63 1.44 2.54 3.5 .73 0.92 1.40 23.73 2.02 3. Read pressure drop on left hand side of the chart.93 4. Enter pressure drop chart with Area Factor and establish intersection with Conversion Velocity (CV) line just determined.99 4. Find the Area Factor from the above table – enter duct height and width.STYLE B Dimension ‘A’ Width (mm) 500 600 700 800 38.23 1.20 18.29 3.89 2.40 22.72 3. Note: Interpolations while not precise.49 1. 1.89 3. 200 150 125 100 90 80 70 60 50 40 CV 30 30 V C 25 Static Pressure (Pa) V C 20 20 V C 15 10 9 8 7 6 5 CV 10 C 7.51.Fire & Smoke Dampers Series IBD – Fire Dampers. Determine Conversion Velocity (CV) by multiplying Area Factor by flow in m3/s (CV = Area Factor x m3/s).59 1.47 1.70 18.66 0.13 2.0 8.10 1.31 1.85 900 20.28 1.06 0.62 2.0 4 V C 3.29 3. are adequate for most calculations.15 1.85 0.08 2.10 26.52 400 48.13 0.94 1.29 4.35 1.80 11.41 5.07 6.60 4.0 10 15 20 30 40 50 70 100 Area Factor (From Table) Notes 1.98 1.51 1.67 1.14 7.80 17.5 = 10. Performance Data Model: IBD-B-V.92 2.6 . 2.27 3.76 0.86 0.70 14.10 13.78 3.85 2.50 10.60 4.2 kg/m3 air density.40 6.80 1.17 1.90 31.34 1.5 3 1 0.18 1.93 0.60 13.47 3.79 2.95 0.81 AREA FACTOR TABLE– DUCT CONNECTION . 3.03 0.63 1.82 4.90 14. For pressure drop through an open IBD-B-V or IBD-B-H fire damper use the following procedure: 1.58 1.2 .66 3.5 V CV 5.84 2.60 0.40 11.25 1.17 2.53 1.73 5.60 4.79 4.01 1.8 1.98 0.0 6. 3.67 8.99 8.4 .77 0. From pressure drop chart.50 4.10 6.92 1.10 9.97 1.30 2.76 2.80 26.2 m3/s.68 5.70 0.78 1.90 25.78 0.30 16.5 3.03 0. pressure drop is 8 Pa. EXAMPLE: Find the pressure drop across a 500 wide x 514 high model IBD-B-V fire damper.31 1.16 1.75 1000 18. 320H © Holyoake Air Management Solutions – 2013 .13 2.40 2.94 1.80 12.61 1200 14.49 1.96 1.3 .75 5.30 37.48 2.07 6.78 1.20 7.20 20.15 0.81 0. From the table using interpolation.0 5.08 1.84 0.70 3.65 4.61 5.16 3. passing 2.47 1.30 11.51 3.87 0.03 0.80 42.79 1.30 15.40 7. or H Dim.10 2.70 8.1 .24 8.30 23.00 31.57 2.15 300 67.55 (All dimensions include 6 mm clearance total between outside of damper frame and inside of duct).5 2.49 2. ‘B’ (mm) 84 179 299 394 514 609 729 824 944 1039 1159 1254 1374 1469 1589 100 200 67. CV = 2.94 0.91 4.40 1.40 10.85 3.90 5.07 6.80 9.66 2.0 2. the Area Factor is 4.71 0. Static Pressure and Conversion Velocities are correct for 1.17 1.0 1.64 0.21 2.67 1. curtain type.Z. or UL 555. or horizontal mounting and shall close by release of a fusible link at a temperature of 71ºC.Z. Part 4. 2 x Single Pole Micro Switch (For Reset And Release Position). Routine service of fire protection systems and equipment. Building Code and shall be built to comply with construction details proven by prototype tests conducted in accordance with AS 30. conforming to the requirements of the Australian and N. – TL ETR – TL = Test Latch with 71º C Link. 321H . Extended Damper Sleeve. to withstand exposure to controlled flame for no less than 4 hours before failure of the assembly as a whole. “Safe Test” Test latches and access doors shall be provided for all fire dampers. Fire dampers shall be interlocking blade. or floor openings utilizing factory fitted galvanised steel mounting sleeves and angles. MSU Universal Mounting Sleeve – SPECIAL OPTIONS Single Pole Micro Switch (For Release Position). or Horizontal Mounting. other materials and practices required to satisfy the Australian and N. Fire dampers shall be Holyoake Series IBD. or by means of an Electro Thermal Resettable Release device incorporating a 71º C Thermal Resettable Release.2012 ( Section 13 ). Fire dampers shall be equipped for either vertical. in terms of Australian Standard AS 1530. Fire dampers shall be installed in wall. with sleeves Holyoake Model IBD-MSU.Interlocking Blade Fire Damper .Series IBD Product Ordering Key and Suggested Specifications IBD Interlocking Curtain Blade Fire Damper – A B C CR CO Duct Connection Style – V – H Vertical. fire resistance test of structures. (Specify Wall Thickness). so that they may be test operated at any time after installation without destroying fusible links and annually in accordance with AS 1851 . all as manufactured and supplied by Holyoake. or any of its components and shall qualify for a 4 hour fire resistance rating. AS 1682. Building Code and AS 1682 Parts I & II and as shown in the manufacturers installation instructions. WIDTH (A)mm x HEIGHT (B) mm Nominal Duct Size. ETR = Electro Thermal Resettable Link. (‘A’ Width Dimension First). x 28 mm O.S. Factory supplied make may vary from time to time. (f) Temperature rating. 1998 and AS 1682. FTC 390. or pneumatic actuator. with air flow and fire exposure from either direction. Because of critical fitting requirements.S.1. All units are fitted with a normally open single pole limit switch activated by the blade. Duct Joints to the damper must be “Break-away” type e. Handing: Remote Indication: Standard Construction Dimensions: Mill. Alternative (close circuit on damper opening) is available. Sleeves and mounting angles are furnished as standard. or floor.15 mm roll formed hat section. 1990. They may be used in either vertical. Control Shaft: 12. (Certified for 240 minute fire rating). ‘S’ cleat. integrity was maintained for a minimum of 4 hours.1 . with integral constant force return spring.Fire & Smoke Dampers Series HFS – Fire & Leakage Rated Smoke Damper Model: HFS-R-146 The Holyoake HFS-R-146 is a fire and leakage rated multi-leaf steel damper. For purposes of the Australian and New Zealand Building Code they have a F.D. M. Maximum Dimensions Per Side mm 0-300 301-762 763-1113 Sleeve Thickness mm 0. HFS-R-146 dampers must not be installed with the axles vertical. specify when ordering.5 mm I. Axles: 84 mm long hex.5 mm O. specify when ordering. of – / 240 / – Tests: Mounting: Actuators: HFS-R-146 With Sleeve and Actuator. (b) Voltage (if electric). HFS-R-146 mounted in a concrete wall. actuators must be factory fitted. Sleeve mount in accordance with AS 1682 . Specify: (a) Make. Finish: Maximum Velocity: Nominal Size is sleeve ID. or floors must be sized to provide room for expansion in accordance with AS 1682. bright zinc-plated pins. Side Seals: Stainless steel type 301. always stated as W x H. Dampers must be fixed square and free from racking. x 1.1. (e) Fail open. Part 2. Blade Linkage: External in frame. Control Linkage: 71ºC fusible link driven crank type. HFS-R-146 requires a 12 mm tolerance gap on all four sides.R. Fire Rating: Tested in accordance with AS 1530. concealed between frame and mounting sleeve.1990.R. (x4 per side. FTC 391. Installation: Frame: Mild steel grade G250 galvanised to Z275. and generally as described on pages 313H ./F.45 0. (c) Pressure range (if pneumatic). x2). BRANZ Fire Test Certificate No. Maximum Nominal Size: Mounting Angles: 40 x 60 x 2 mm galvanised steel angle. Sleeve Material: Galvanised Steel Type Z275.317H and 323H. Standard left hand as illustrated.55 0.R.4. Duct Connection: Mounting Sleeves are supplied raw edged. BRANZ Fire Test Certificate No. for the prevention of the spread of fire and/or smoke through ducted air systems. 322H © Holyoake Air Management Solutions – 2013 . 167 x 23 x 1. Holes through walls. (Certificates are available upon request). bright zinc-plated.1990. Self contained as a fire damper and externally operable by electric. Blades: Mild steel grade G250 galvanised to Z275. in that order Note: Add 6 mm to Nominal W (Width) and Nominal H (Height) for Internal Duct size 10m/s Frame Bracing: Diagonal corner braces on all dampers above 300 x300. Standard is set to close circuit on damper closure.2 mm wall 304 stainless steel tube. or non-spring return (if electric). Bearings: 12. Blade Rotation: Parallel only. Alternative right hand is available. or between plenums.L.D. (d) Spring.15 mm roll formed “double vee and hex.g.75 Minimum Nominal Size: 200 mm Wide x 230 mm High. HFS-R-146 mounted in a plasterboard wall. or horizontal planes.S. on 146 mm shaft centres. Latch: Stainless steel with 71ºC fusible link. pressed into frame. 157 x 1.1990. link bar pin. grease-packed ball races. with machine notched joints and corner gussets. force fitted to hex pin and S. (Certified for 30 and 60 minute fire rating). mechanically locked and welded to half hex blade channel. Cranks: 6 mm M. or closed (if spring). constructed to comply with AS 1668. Blade Seals: Silicon seal on blade edge.D. 900 mm Wide x 1113 mm High. with blade axles located within the fire partition. then: Top + Bottom Blade Centres Blade Stop Heights A = H . 71°C Fusible Link. of the same fire rating and structural integrity as the surrounding wall. select exact modular height. specify special length. Grease Packed & Sealed Ball Bearings. 4 Slotted For M6 Bolts*. of Blades 1 2 3 4 5 6 7 H Min 230 376 522 668 814 960 1106 H Max A Min B Min C Min 375 115 33 175 521 115 33 175 667 115 33 175 813 115 33 321 959 115 33 467 1105 115 33 613 1113 115 33 759 A B Note: Add 6 mm to Nominal W (Width) and Nominal H (Height) for Internal Duct Size. C = H .230 = 35 + 175 = 210 2 (Mounting Sleeve and Actuator Omitted for Clarity).230 = 35 + 115 = 150 2 A Blade Edge Seals. Exact modular height is where H = H Min. 5 60 x 40 x 2 GMS Fixed MTG Angle 6 C 4 3 H (Nominal) H 6 2 60 x 40 x 2 GMS 55 200 Max 80Min 450 1 100 W (Nominal) 60 165 Min 125 Notes 1 Standard sleeve length of 450 mm will accommodate walls 80 . Jack Shaft Centre From Top of Casing SS 304 Tubular Shaft. to comply with AS 1682.NOMINAL DIMENSIONS No. 55 146 15 H (Max 1113 Nominal) TABLE 1 .H Min + C Min 2 167 22 e.H Min + A Min 2 B = H .200 mm thick. C HFS-R-146 B 300 = 300 . 7 Illustration details an example of arrangement to be supplied and is as tested. (Supply and fit by others ). Part 2.g. High Temperature Mineral Wool. 3 Typical actuator. 4 M6 galvanised bolts (* Refer to page 313H ‘Fire Damper Installation Notes’). 40 Limit Switch. For smallest damper.230 = 35 + 33 = 68 2 C 300 = 300 .900N0o) (M(aMxa9x WW For maximum open free area. (in either width. 2 Limit switch tails. or height). 1990. 5 Packing in the expansion gap. 300 Height B A 300 = 300 . 8 Trim sleeves as per note 6 on page 317H. fits within overall damper and mounting angle height. For non modular height use the following: Determine number of blades from Table 1. 6 Multiple assemblies need to be individually operated and separated by a minimum of 200 mm of structural support. 0.Dimensional Data – Series HFS Model: HFS-R-146 m). For other wall depths. 323H .H Min + B Min 2 SS 301 Side Seal. Latch With Fusible Link. 70 3.84 3.70 5.37 1.48 3.56 2.69 5.3 m3/s. Enter pressure drop chart with area factor and proceed up to the appropriate conversion velocity (CV) line.33 4.00 4. Pressure drop data is for dampers tested with ductwork on both the up and downstream sides.91 21.25 = 6.90 4.48 350 31.78 2.81 10.03 18. 1. 2.82 700 14.24 12.03 6.36 4.54 13.10 3.83 10.25.16 600 17. are adequate for most calculations).70 1.These values need to be suitably increased where dampers are mounted with ductwork on one side only.94 9.31 18. Notes 1000 500 400 300 200 25CV 100 15CV 50 40 30 10CV Static Pressure (Pa) 20 7.50 1.50 3.00 7. 324H © Holyoake Air Management Solutions – 2013 .19 400 27.90 3.05 7.84 3.75 2. Find conversion velocity (CV) by multiplying area factor for selected size damper by flow rate in m3/s. Read the pressure drop (Pa) on the left hand side of the chart.74 21.3 x 5. Determine area factor for damper by entering the area factor table with duct width and height. (Note: Interpolations while not precise.5CV 5CV 4CV 10 5 4 3 2 1 1 2 3 4 5 6 7 8 10 20 30 40 50 60 70 80 100 Area Factor (From Table) Notes 1.57 2.33 1.90 3. or when mounted onto plenum walls.26 4.37 3.49 5. Static Pressure and Conversion Velocities are correct for 1.04 6.45 850 11.16 8.96 1.67 6. of Blades 1 2 3 4 5 6 7 200 66.29 1.46 3.45 6.93 4. From pressure drop chart.00 2.36 900 11.65 5. 2.92 3.2 kg/m3 air density. Pressure Drop is 12Pa.86 2.Fire & Smoke Dampers Series HFS – Performance Data Model: HFS-R-146 Nom Ht.54 4. 3.825.71 AREA FACTOR TABLE Nominal Width (mm) 450 500 550 23.35 3.02 10.08 3. 2.25 4.45 9. From the table the area factor is 5.66 17.78 2. 3.92 1.64 5.26 8.88 10.67 750 13.66 4.43 1. or ASHRAE System Design Guides).26 2.42 3.81 2.28 Note: Add 6 mm to Nominal W (Width) and Nominal H (Height) for Internal Duct Size. Data is for the specific sizes listed in the Area Factor table.59 1.94 5.13 1.07 9. 3.30 2. (mm) 230 376 522 668 814 960 1106 No.53 2. 1. CV = Area Factor x m3/s.55 800 12.35 5.82 1.05 1.70 5.44 2.81 1.23 2.79 13.02 6.91 8.58 2. Use the table and chart to determine the pressure drop through HFS – R– 146 Fire / Smoke Dampers.13 7.20 1.67 300 38.11 2. EXAMPLE: Find the pressure drop across a 350 wide x 814 high model HFS-R-146 Fire/Smoke Damper handling 1.99 650 15.97 14. CV = 1.40 5.56 29.59 2.15 3.31 6. For other sizes use the next size down and make a proportional adjustment based on the approximate increase in free area. (Refer to SMACNA.72 250 48. in accordance with their design failure position. Fire and Leakage Rated Smoke dampers shall be multi-leaf dampers. Extended Damper Sleeve (Specify Wall/Slab Thickness). WIDTH (W)mm x HEIGHT (H)mm Nominal Size Sleeve ID (‘W’ Width Dimension First). not in the vertical position.33 Important Note HFS dampers must be transported with their blades horizontal. 325H .4. Alternatively the fire/smoke damper can be activated by a remote signal from a fire alarm panel (supply and fit by others). – MSU – Universal Mounting Sleeve.2012 ( Section 13 ).Fire & Leakage Rated Smoke Damper – Series HFS Product Ordering Key and Suggested Specifications HFS-R-146 – Fire and Leakage Rated Smoke Damper. (e) Fail open.1 11. or biannually tested as determined by AS 1851 . Fire and Smoke dampers shall be equipped for either vertical. shall be Holyoake series HFS-R-146 with Sleeves. (b) Voltage (if electric). (d) Spring. Fire and Leakage Rated Smoke dampers. or non-spring return(if electric). Holyoake Model HFSR146 . Routine service of fire protection systems and equipment. or any of its components. Reverse Switching (Close Circuit on Damper Opening). constructed to comply with details proven by prototype tests conducted in accordance with AS 1530. Angles & Motor) HFS-R-146 250 x 250 (Inc Sleeve. are complete with a suitable electric. Guide Product Weights Fire & Leakage Rated Smoke Dampers HFS-R-146 200 x 230 (Inc Sleeve. or closed (if spring). – ACTUATORS Specify (a) Make. or horizontal mounting. To withstand exposure to controlled flame for no less than 4 hours before failure of the assembly. Fire and Smoke dampers should be annually. or pneumatic actuator and shall release by a fusible link at a temperature of 71ºC. Angles & Motor) Approximate Weight in Kg 10. (f) Temperature rating. OPTIONS Reverse Handing (Right Hand).MSU and shall be as manufactured and supplied by Holyoake. (c) Pressure range (if pneumatic). Sectional View Through Plasterboard Wall. The unique Series LR damper design Minimal Heat ensures that the damper blade always Transfer Into stays within the confines of the wall Wall Cavity and provides a cost effective solution. forms a solid barrier against flame. The damper blade is designed to reduce the transfer of heat radiation through the firewall. For Plasterboard or Masonry Walls. whilst maintaining the walls integrity. Standard Insulated. The innovative heat radiation blocking damper blade. LR 150 4. 4 Hour FRL/FRR and Radiation Protection to AS 1530 part 4. The low leakage insulated damper blade assembly with blade tip sealing ring. It is supplied complete Low Radiation Fire & Smoke Damper Approximate Weight in Kg with external low radiation sleeve and mounting flanges. will snap closed within seconds upon the air temperature reaching 71˚C.1997 has proven that the damper will stop the passage of fire and smoke through a fire rated wall for at least 4 hours.>`ˆ>̈œ˜Ê­ÃÊ/iÃÌi`®° UÊœÜÊi>Ž>}iʘÃՏ>Ìi`Ê >`i° UÊ1«Ê̜Ê{ÊœÕÀʈÀiÊ. Complying with AS/NZS 1668. providing rapid temperature response. The Holyoake LR Fire Smoke damper has been designed to provide premium protection for occupants and building structures in the event of a fire.>̈˜}° UÊ*Ài‡˜ÃՏ>Ìi`Ê-iiÛi° UʈÀÊ >>˜Vˆ˜}Ê.4 . smoke and hot gases. smoke and control damper into Guide Product Weights one easy to install.1 . >>˜Vˆ˜}Ê`>“«iÀ >`ÕÃÌ>Liʅ>˜`i The LR Damper integrates both a fire. Furnace testing to AS 1530.Fire & Smoke Dampers Series LR – Low Radiation Fire Damper Model: LR The Holyoake Series LR (Low Radiation) Fire Dampers are designed to impede the spread of fire and heat within building compartments.17 Boxed Fire protection is provided by a fusible link and damper blade that seals the duct shut in the event of a fire.1998 the LR Fire Damper is certified for a 4 hour rating in a masonry wall and a 2 hour rating in a plasterboard wall. providing induct heat radiation control. Non . while the outer solid insulating sleeve ensures minimal conduction of heat into the wall cavity. Standard Insulated.Conductive Insulated Damper Blade Features: UÊœÜÊi>ÌÊ. maintain and test unit. >“«iÀ° UÊ`ÕÃÌ>LiÊvœÀÊ6>Àˆ>LiÊ7>Ê. i«Ì…ð Solid Insulating Sleeve Fusible Link Blade Tip Sealing Ring Sliding Flange Permanently Attached Flange Optional Un-insulated. Sectional View Through Masonry Wall. Insulated Damper Blade Galvanised Steel Sleeve Fusible Link Blade Tip Sealing Ring Permanently Attached Flange 326H Sliding Flange Fire Proof Sealant © Holyoake Air Management Solutions – 2013 . Optional Un-insulated. For Masonry Walls Only. Performance and Dimensional Data – Series LR Rating Dimensions: FRL/FRR rating: Exova WarringtonFire Aus Pty Ltd – /240/ – Heat radiation less than 10 kW/m2 Test Certificate SFC41085.3 Framed Walls*  (* Includes steel and timber framed walls). * In accordance with Exova WarringtonFire 45757.1.3 Masonry Walls FRL/FRR rating: Exova WarringtonFire Aus Pty Ltd – /120/ 30 * Heat radiation less than 10 kW/m2 Test Certificate SFC41084. to the requirements of AS 1682 Part 1. Performance Data . NATA certified testing to AS 1530 part 4. Installation is simple. 4 On the opposite side of the wall mount the sliding flange over the LR Damper sleeve and fasten to both the damper and wall. A circular hole is made through the wall where the duct is to penetrate. Installation 1 The LR damper has one flange permanently attached.Ø160 14 2 Mount the LR damper through the hole in the wall. Insert LR Damper Through Hole in Wall Fixing 4. 12 3 Fix the outside flange. Note Series LR dampers are suitable for Wall Mounting Only. 10 8 In plasterboard walls the weight of the damper must be supported independently of the wall lining. 6 4 2 0 0 500 1000 1500 Pressure Behind Damper (Pa) Screw Fix As Provided 1. Static Pressure Drop When Damper Fully Open Flow (l/s) ∆Ps (Pa) fully open 10 20 40 60 80 100 120 140 160 180 200 1 2 5 9 16 24 36 47 61 78 94 LR 150 A 145 B 110 C 95 -170 D 430 E 137 Note: All Dimensions in mm. The handle may also be used to check the functioning of the damper when inspection is due. Fix attached flange to wall 2. Fixing 3. Cut Size In Wall mm Insulated LR150 Ø180 . The clamp nut on the handle must be tightened to hold the damper blade in place. Cut Hole Damper Setting The damper can be used for balancing and set using the attached external handle.Ø185 Leakage When Damper Shut Leakage (l/s) Un-insulated LR150 Ø155 . in accordance with plasterboard manufacturers specifications. Attach Sliding Flange & Fix to Wall 327H . Routine service of fire protection systems and equipment. LR Fire Dampers should be annually tested as determined by AS 1851 . An external lockable handle is included as standard that can be used to position the damper blade to provide volume control. Heat radiation emitted during testing to AS 1530. No additional insulating material will be needed to install the Low Radiation Un-insulated Fire Damper.4 was less than 10 kW/m2. LR Fire Dampers should be annually tested as determined by AS 1851 .4 and to the requirements of AS 1682. No additional insulating material will be needed to install the Low Radiation Fire Damper.2012 ( Section 13 ).2012 ( Section 13 ).Fire & Smoke Dampers Series LR – Low Radiation Fire Damper Product Ordering Key and Suggested Specifications LR150 OPTION Model Standard (Insulated) LR150 OPTION Model Un-insulated Holyoake LR Low Radiation Fire Dampers shall have a 4 hour rating in a masonry wall and a 2 hour rating in a steel. The rating shall be certified to AS 1530. LR Low Radiation Fire Dampers contain a fusible link that releases and allows the damper to close upon reaching 71ºC. Low Radiation Un-insulated Fire Dampers shall be Holyoake Series LR (Un-insulated) and shall be manufactured and supplied by Holyoake.1. LR Low Radiation Un-insulated Fire Dampers contain a fusible link that releases and allows the damper to close upon reaching 71ºC.4 and to the requirements of AS 1682. Patent Pending 328H © Holyoake Air Management Solutions – 2013 . or timber framed walls). Routine service of fire protection systems and equipment. or timber framed wall. (not suitable for steel. The rating applies to fires on both sides of a fire wall. Low Radiation Fire Dampers shall be Holyoake Series LR Standard (Insulated) and shall be manufactured and supplied by Holyoake.1. The rating shall be certified to AS 1530. Holyoake LR Low Radiation Un-insulated Fire Dampers shall have a 4 hour rating in a masonry wall. The rating applies to fires on both sides of a fire wall. An external lockable handle is included as standard that can be used to position the damper blade to provide volume control. Heat radiation emitted during testing to AS 1530.4 was less than 10 kW/m2.
Copyright © 2024 DOKUMEN.SITE Inc.