I-CONFIGURE CADWORX HELPSAutoDrawingSplit Invokes automatic splitting of drawings. Unless IgnoreUserSplitPoints is set to True, this property is ignored if you manually-added pipeline split points are present in the pipeline data file. True - Calculate the volume of pipeline graphics that can be satisfactorily displayed on the selected drawing size, and generate the required number of isometrics to contain the complete pipeline. False - Use NoOfDrawings to specify a fixed number of drawings. Setting to False allows you to directly dictate how many isometric drawings are to be produced for a pipeline. Only set the number of drawings in special cases, such as for single pipeline runs, since the setting is applied to all the pipelines in a run. IgnoreUserSplitPoints True - Ignore user-defined drawing split points present in the piping data file. False - Process user-defined drawing split points present in the piping data file. NoOfDrawings Specifies the number of drawing sheets required for split control. 0 - Automatic control of drawing numbers. Value - User-defined number of drawings. Type a value in range 1-99 Unless IgnoreUserSplitPoints is set to True, this property setting is ignored if manually placed pipeline split points are present in the pipeline data file. This option dictates how many drawing sheets are extracted for a pipeline. Therefore, you should use this option only for special cases for single pipe runs as the setting applies to all the pipelines in a run. To use the NoOfDrawings option, you must set the AutoDrawingSplit option to False. IsometricType Sets the required isometric type. Combined - Fabrication, erection and offshore information. Erection/Offshore - Erection/offshore type isometric drawing. Fabrication Only - Fabrication only isometric. Flat Spool (Flat) - Individual flat spool isometrics (maximum legs flat). Flat Spool (Parallel) - Individual flat spool isometrics (maximum legs parallel). Spool - Individual spool isometrics As-Built orientation. Material List Only - Isometrics suppression - no isometric drawings are generated. Combined Material - Combined material list only, without pipeline graphics. Erection Material - Erection material list only, without pipeline graphics. Fabrication Material - Fabrication material list only, without pipeline graphics. Spool Material - Spool material list only, without spool graphics. IsoScale Controls the finished isometric drawing size. You can increase or decrease the final plotted isometric size from the size defined by DrawingSize, or CustomHeight and CustomWidth. 0 or 100 - No scaling change (100% of set size). The software generates the isometric drawing at the size defined by DrawingSize or CustomHeight and CustomWidth. n - Scale the drawing to increase or decrease the final isometric size by n%, where n is an integer number. For example, n = 71 generates a reduced size drawing at 71% of the set size, such as A2 reduced to A3. Whereas n = 120 generates an increased size drawing at 120% of the set size. MinAngleOffset Controls how the software interprets and acts on small angular deviations detected in the pipeline input data. These deviations can lead to small unwanted skews being generated on the isometric. You can define an angular cut-off value with this property so that any skew that is found to have an angular deviation below this value is ignored by the software and not treated as a skew. The default setting is 0. If a pipeline split occurs along a section of pipe.Output pipeline name as part of the drawing continuation message.Default for what ISOGEN considers to be the limit for drawing information content. This value is a scale factor expressed as a percentage. All On Same Sheet . Type a value in range 1-10. 0 or 100 . . is written to the message file. PipeLineSplitting Controls the amount of drawing data that triggers a drawing split. UNACCEPTABLE SPLIT POINT. Plots are produced with the message. True . depending upon the PlotFileLenth setting One Per File . If a particular value does not work. DrawingsPerFile Controls how and where any isometric drawings are to be output. False .Use the user-defined integer number to increase or decrease the scaling effect as a percentage. generate name using selected sequence method. PipeLineScale Increases or decreases the scale of the pipeline picture part of the isometric only. 0 or 100 .Default for pipeline splitting to function as normal when the split point occurs along a section of pipe. This limit is set within the software and varies for each size of drawing. resulting in a less crowded drawing. Reject . Normal . One Per Sheet .Allocate plot file name using selected sequence method after deleting previously generated files. PipeNameInContMessages Controls whether the pipeline name is output as part of the drawing continuation message on the isometric. PipeLineSplittingInTube Controls the actions taken by the software whenever the ISOGEN automatic pipeline split facility selects a split point that is located in a straight length of pipe. if it is being used. unaltered. material list. title block and line summary areas. The relevant split point information is passed back to the 3D design system using the isometric repeatability file. True . This option is intended only for modest modifications of the drawing whitespace. OverwritePlotFile Overwrites and deletes any plot files existing with the same name. UNACCEPTABLE SPLIT POINT plotted at the top of each affected drawing. is written to the message file. No plots are produced and no information is written to the isometric repeatability file for the pipeline. Value . Only applies to SmartSketch (IGR) and SmartPlant Shape2D (SHA) formats. the warning message. while leaving all other parts.Use the user-defined required angle tolerance.Plot each ISOGEN drawing sheet to a separate sheet within a single drawing file.Increase or decrease the drawing information content as a percentage.Allocate next available plot file. such as the drawing frame. gradually adjust the value and re-extract the drawing to check the results. Message .Use the default scale. UNACCEPTABLE SPLIT POINT. Value . the warning message. Value . No information is written to the isometric repeatability file for the pipeline. you can re-scale the pipeline picture and all text pointing to it.5 for 0. Setting a value less than 100 causes less of the pipeline to appear on each drawing before automatic splitting occurs.Use no angular offset tolerance. such as 0. Specify a value in the range 90-110. 0 .Output isometric drawings generated during a run to a single plot file or to a series of plot files.5-degrees.Generate an individual plot file for each isometric drawing. Using this property.If a pipeline split occurs along a section of pipe. 420 x 594 mm A3 .17" x 22" D . Drawing Identifier . False .Use the default for 55 lines per page. StartDrawingNumber Allows the first sheet to start at an alternative number instead of starting with drawing number 1 0 .34" x 44" PrintedOutputPageLen Controls the number of lines per page on any printed output (reports) generated by the ISOGEN system. and the required PlotfileLength is different than the built-in default value of 3275mm. If PipeNameInContMessages s is True.841 x 1189 mm A1 . True .Start first sheet at drawing number 1.594 x 841 mm A2 . Message is always output if pipeline does not connect using increased tolerance.5" x 11" B .210 x 297mm ANSI Sizes A . False .8.Suppress output of disconnected pipeline message at top of drawing if pipeline has connected using the increased tolerance.The required plot file length in whole mm's. PostScriptSize Specifies the PostScript plotter size.22" x 34" E .Output a standard drawing continuation message. 0 .Default for plot file length of 3275mm.Output a drawing continuation message that includes SPOOL-DRAWING-SEQUENCE-NUMBER.Specify the required number of lines to be output per page.Output a standard drawing message. Type the required value (integer number). 0 . PlotFileLength Controls the physical length of the plot file that is generated by ISOGEN. Value . SetPipelineDisconnected Specifies an IDFGEN-generated diagnostic.Output a drawing continuation message that includes PIPELINEDRAWING-SEQUENCE-NUMBER.11" x 17" C . Blank . Pipe Reference .297 x 420 mm A4 . It is only necessary to set this property when OneFilePerDrawing is set to False. .Output a drawing continuation message that includes CLIENTDRAWING-IDENTIFIER. Spool Drawing Sequence Number .Output a drawing continuation message includes pipeline name.Set pipeline to disconnected when an increased tolerance is used to connect pipeline.Start first sheet at x+1. x . Sequence Number . The maximum length is limited to 3350mm. European Sizes: A0 . Value . PipeNameStyle Controls the style of pipeline name output for drawing continuation messages. Output a disconnected pipeline message at top of drawing. Acceptable options are:: Maximum Legs Flat Parallel Legs Flat Longest Leg in E/W plant. Include . The default setting is Include. False . True . including such things as material lists.Use true scaling of isometrics (proportional pipe lengths).Suppress display of continuation graphics on spool isometric drawings. WeightOutput Controls how component weights are displayed on the isometric drawing. and material control files.Display Up direction on longest leg of flat spool. UseI01TypeExts Controls the use of I01 type extensions. LinearWeightDenominator Specifies the units for the linear weight denominator. False . False . For example: LBS/M when weight is in LBS.SupportAdditionsWeight Controls inclusion of the weight of additional material associated with supports when performing centreof-gravity calculations. The default setting is None. Where a spool continues on another spool. FlatSpoolUpArrow Allows the Up direction to be displayed on the isometric drawing.Use I01 type filename extensions on all plot files generated that do not use a user defined plot file prefix. None . Applies to all outputs. Ignore . For example: LBS/FT when weight is in LBS.The linear denominator is in metres. .Use normal filenames / extensions.Ignore the weight of additional materials. weight output on drawing frame.Use normal scaling of isometrics (variable pipe lengths). TrueScale Attempts to adjust the length of sections of pipe to be proportional to their actual physical length. None . True .) LinearWeightDenominator specifies the units used for the linear weight denominator. regardless of the units used for weights. Kg .The linear denominator is the default. Second Longest in N/S plane Setting FlatSpoolOrientation to Parallel Legs Flat is not recommended. True .Display North arrow on all drawings except flat spool isometric drawings. The Up direction shown is relevant to the longest leg length output in the horizontal plane (bottom left to top right) of the isometric drawing. m . The weight unit is specified in the WeightOutput property.Display continuation graphics on spool isometric drawings. Second Longest in N/S plane. ContinuationGraphicsOnSpoolIsos Controls the display of continuation graphics at the ends of spool isometric drawings. False . True . FlatSpoolOrientation Controls placement of the longest pipe in a flat spool drawing. ft .Include the weight of additional materials. This setting is only applicable when FlatSpoolOrientation is set to Longest Leg in E/W plant. and KGS/FT when weight is in KGS.Input and output all weights in pounds (Lbs.Input and output all weights in kilograms (Kgs). Lb . irrespective of the units used for weights. and KGS/M when weight is in KGS. and KGS/M when weight is in KGS. For example: LBS/FT when weight is in LBS.Output no weight information. an appropriate continuation message is also output on the isometric drawing.The linear denominator is in feet. direction. or skewed. Value . it overwrites the setting defined by NorthDirection. The example drawing below shows pipe oriented in a southeasterly direction: The next example shows the same pipe rotated 45º so that it is now in a southerly direction: 0 .Orient isometric drawings in the horizontal plane in a clockwise direction by the specified number of degrees.The following example shows the Up direction rotated 90-degrees counter clockwise: DrawingRotationAngle Controls the rotation of the isometric drawing in a clockwise direction by a specified number of degrees. The ability to orient pipelines in the horizontal plane so that the majority of skewed pipeline sections are rotated to a primary direction can simplify isometric drawing output. Where pipelines are oriented in a non-primary. If you define a value. the subsequent isometric drawing output can be congested and difficult to read. . Enter a value in tenths of a degree up to a maximum of 3600.Orient isometric drawings in the horizontal plane using the setting defined by NorthDirection. This is the default setting.