Helkama Bica Marine and Offshore Cables (1)

March 26, 2018 | Author: masterfinix | Category: Cable, Wire, Electrical Conductor, Insulator (Electricity), Alternating Current


Comments



Description

5/2014Marine and Offshore Cables Contents Helkama – a true specialist in marine cables ......................2 Approvals..................................3 0,6/1kV cables LKM-HF.....................................4 LKMM-HF .................................8 LKSM-HF.................................10 LKMSM-HF .............................14 LKAM-HF.................................16 LKEM-HF.................................18 EMC cables LKSM-EMC..............................20 LKSM-EMC-FRHF....................24 RFE-EMC.................................28 RFE-EMC(i) .............................30 1,8/3kV cables LKSM-VFD ..............................32 0,6/1kV FR cables LKM-FRHF...............................34 LKSM-FRHF ............................38 LKAM-FRHF ............................42 250V cables LKM-HF ..................................44 LKSM-HF.................................46 LKAM-HF ................................48 RFE-HF ....................................50 RFE-HF (i) ...............................52 RFA-HF ....................................54 RFA-HF (i) ...............................56 250V FR cables LKM-FRHF ..............................58 LKSM-FRHF ...........................60 LKAM-FRHF ...........................62 RFE-FRHF................................64 RFE-FRHF (i) ...........................66 RFA-FRHF................................68 RFA-FRHF (i) ...........................70 Optical fibre cables FXMSU ....................................72 FXMMS ...................................74 Cabled optical fibres characteristics .........................76 Technical information General information.................78 Bending radius ........................79 Diameter tolerance ..................79 Core identification ...................79 Current rating..........................80 Short circuit current ................81 Short time duty .......................82 Voltage drop............................83 Subject to change without prior notice. See latest updates on our webpage www.helkamabica.com HELKAMA — a true specialist in marine cables Helkama is specializing in development and production of marine and offshore cables. Our experience in this field goes back fifty years. Our high technical quality has been achieved by continuous development work supported by our clients. In this catalogue we proudly present our most comprehensive range of marine cables. We have chosen to produce only halogen-free cables. They remarkably improve the fire safety of the ships by not emitting toxic burning fumes or thick smoke. In addition no corrosive gases damaging the ship and its equipment are emitted in case of a fire. Using the latest technology we have been able to reduce cable weight and size to a minimum and still maintain quality as well as enabling easy and fast installation. The halogen free range of cables includes both flame-retardant (IEC 60332-3) and fire resistant (IEC 60331-series) cables. Helkama marine cables are approved by all major classification societies. As a specialized and independent company, focusing on service, we have been able to grow steadily by quickly responding to our customers’ needs. Our short delivery times, backed up by extensive stocks, enable us to deliver punctually and keep our clients satisfied. This remains our goal for the future, too. Marine cable factory in Kaarina, Finland. 3 TYPE APPROVALS Type Approval Certificates for factories in Finland and China www.helkamabica.com Please check updated approval situation on www.helkamabica.com Marine cable factory in Shanghai, China. 0,6/1kV CABLES 4 LKM-HF Unarmoured power and control cable 0,6/1kV DESIGN: STANDARDS: IEC 60092-353, design 1. Conductor - stranded copper conductor 1,0-10mm2 IEC 60228, class 2 - stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex) - tinned stranded copper conductor on request Flameretardant 2. Insulation Fire- XLPE plastic IEC 60092-351 resistant 5/2014 3. Bedding - separator tape 4. Sheath - polyolefine plastic, SHF1 IEC 60092-359 - on request, thermosetting polyolefine, SHF2 - standard colour black, other colours on request Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com 0 64.5 27.5 22.0 29.5 3x2.5 Part number Normal G-type – 28396 27000 27002 27004 27006 27009 27011 27013 27015 27017 27019 27021 27023 27025 27027 27029 – – – – – – – – – – – – 25672 25689 25704 25706 25708 26072 26074 26076 26078 26080 26082 26085 26086 26088 26090 1x1.6/1kV . for example.0 15.5 2x2.5 20.0 25.0 10.5 14.5 33.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2014 – 25636 25638 25640 25642 25644 25647 25649 25651 25653 25655 25657 25659 25661 25663 25665 26047 25581 25670 25686 25702 25701 25717 26054 26055 26056 26057 26058 25582 25671 25688 25703 25705 25707 26071 26073 26075 26077 26079 26081 26083 26084 26087 26089 Number of conductors & cross-section n x mm2 0.0 3x1.5 31. 3G1.5 23.5 10.0 5.0 16.5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1.0 44.5 9.0 11.5 34.5 40.0 8.5 Approximate weight kg/km 35 40 55 70 95 140 185 290 385 540 750 975 1225 1545 1880 2495 3055 65 80 115 155 240 360 490 755 1035 1455 1995 80 100 145 200 310 465 625 970 1325 1880 2615 3455 4365 5485 6800 9045 Current Rating A at +45°C 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 13 16 21 28 36 50 66 86 107 137 168 199 232 267 300 355 Min. bending radius fixed installation mm 20 25 25 30 30 35 40 50 50 60 70 80 90 100 165 185 200 30 35 40 45 50 60 70 85 95 170 190 35 40 45 50 55 65 75 90 100 180 210 240 270 305 345 390 G-type is with yellow/green earth conductor and marking on sheath is.5 12.5 50.0 27.5 1x2.5 57.5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 3x1.0 17.0 11.0 1x1.0 9.0 19.5 6.5 12.0 14.5 24.5 17.5 13.5 21.5 8.5 8.5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 3x240 Flex Nominal outer diameter mm 5.0 30.0 9.0 7.0 2x1.5 7.6/1kV CABLES LKM-HF 0.5 5. helkamabica. fax +358 2 237 2428.5 14.0 19.5 11.5 16.0 12.5 14.0 44.0 22.5 10.5 27.0 24x1.0 27x1.5 19.0 37x1.5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 5x70 Flex 7x1. for example.0 5x1.0 42.0 16x1.0 11.0 14x1.5 27.com .0 30x1.5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 5x1.5 13.0 4x1.5 10.0 12x1.5 15.5/2014 0.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page Tel.5 4x2.6/1kV CABLES 6 LKM-HF 0.5 33.0 10x1.5 37.5 13.0 Approximate weight kg/km 95 135 180 260 385 585 800 1250 1695 2420 3350 4465 5590 125 160 220 320 475 720 970 1545 2100 2980 4175 155 225 250 280 325 365 465 510 555 680 Current Rating A at +45°C 13 16 21 28 36 50 66 86 107 137 168 199 232 10 13 17 23 30 42 55 71 89 114 139 9 8 8 7 7 7 6 6 5 5 Min.0 16. bending radius fixed installation mm 35 40 45 55 60 70 80 100 170 200 230 270 300 40 45 50 55 65 75 90 165 185 225 260 45 55 55 60 65 65 80 80 85 90 G-type is with yellow/green earth conductor and marking on sheath is. www.5 15.5 21.5 5x2. +358 2 410 8700.0 19.0 Nominal outer diameter mm 8.0 38.0 19x1.6/1kV Part number Normal G-type 25583 25673 25690 25725 25727 25729 26101 26103 26105 26107 26109 26111 26113 25584 25676 25692 25864 25866 25868 26131 26133 26135 26137 26139 25585 25586 25587 25588 25589 25590 25592 25593 25597 25595 – 25674 25691 25726 25728 25730 26102 26104 26106 26108 26110 26112 26114 – 25677 25693 25865 25867 25869 26132 26134 26136 26138 26140 – – – – – – – – – – Number of conductors & cross-section n x mm2 4x1.0 13.5 9.5 20.5 24.0 12.5 30. 3G1.5 18.5 49. 5 17.5 17.5 27x2.5 20.5 37x1. bending radius fixed installation mm 50 60 65 70 70 75 90 90 100 55 70 70 75 80 85 100 155 5/2014 25678 25667 25680 25991 25989 25682 25875 25684 25675 25694 25993 25696 25995 25997 25873 25877 26141 Number of conductors & cross-section n x mm2 0.5 24x2.0 25. 3G1.5 Nominal outer diameter mm 11.5 7x2.5 19x2.5 12x1.5 10x1.5 16.5 19x1.5 15.5 24.5 12x2.7 Part number Normal G-type 25679 25668 25681 25992 25990 25683 25876 25685 25687 25695 25994 25874 25996 25998 25872 25878 26142 7x1.5 16x2.0 15.6/1kV CABLES LKM-HF 0.5 18.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Min.5 25.0 Approximate weight kg/km 200 290 335 380 430 495 635 700 920 285 410 465 535 605 690 900 990 Current Rating A at +45°C 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 G-type is with yellow/green earth conductor and marking on sheath is.0 17.5 14x2.5 16x1.5 14x1.0 13.5 22.6/1kV .5 24x1.0 18. for example.5 10x2.0 22.5 19.5 27x1. www. manufacturer's name and meter marking printed on the sheath Tel. cable type. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number.5–10mm2 IEC 60228.com .standard colour black.stranded copper conductor 1.stranded copper conductor 16–150mm2 IEC 60228. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships.6/1kV DESIGN: STANDARDS: IEC 60092-353.XLPE plastic IEC 60092-351 3. standards. SHF2 . Sheath .2kV) DC 0. Insulation . class 5 .9/1. temperature.extruded filler 4. thermosetting polyolefine. Main characteristics Rated voltage AC 0. Conductor .5kV (if voltage to earth does not exceed 0. SHF1 IEC 60092-359 .0. fax +358 2 237 2428.tinned stranded copper conductor on request 5/2014 2. voltage.6/1kV (1.6/1kV CABLES 8 LKMM-HF Unarmoured power cable with extruded filler 0.on request. Bedding .polyolefine plastic.9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables.helkamabica. design 1. cable size. +358 2 410 8700. class 2 . production month. 5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 27532 27534 27536 27538 27540 27543 27545 27547 27549 27551 27564 27568 27572 27576 27580 27585 27589 27593 27597 27601 27605 27609 27613 27628 27632 27636 27640 27644 27649 27653 27657 27661 27665 27692 27696 27700 27704 27708 27713 27717 Nominal outer diameter mm 5/2009 Part number Normal G-type Number of conductors & cross-section n x mm2 0.9 – – – – – – – – – – 27566 27570 27574 27578 27582 27587 27591 27595 27599 27603 27607 27611 27615 27630 27634 27638 27642 27646 27651 27655 27659 27663 27667 27694 27698 27702 27706 27710 27715 27719 Approximate weight kg/km Current Rating A at +45°C Min.0 11.5 17.5 12.0 14.0 24.0 42.5 27. bending radius fixed installation mm 2x1.5 16.5 5x4 5x6 5x10 5x16 5x25 9.5 14.5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 4x1.0 13.5 21.0 32.5 10.6/1kV .0 24.0 53.5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 3x1.5 12.0 25.5 11.5 10.5 11.5 30.0 37.5 14. for example.5 18.5 2x2.6/1kV CABLES LKMM-HF 0.5 19.0 30.5 27.5 15.0 10.5 110 155 205 285 420 630 970 1340 1855 2510 130 180 245 350 515 770 1170 1600 2220 3090 4055 5070 6425 165 215 305 420 635 935 1440 1955 2735 3790 195 255 360 515 770 1145 1750 20 26 34 44 61 80 105 130 167 204 16 21 28 36 50 66 86 107 137 168 199 232 267 16 21 28 36 50 66 86 107 137 168 13 17 23 30 42 55 71 35 40 45 50 60 75 90 155 180 205 35 45 45 55 60 80 100 160 190 220 255 285 320 40 45 50 60 70 85 160 180 210 245 45 50 55 60 75 95 175 G-type is with yellow/green earth conductor and marking on sheath is.0 12.5 4x2. 3G1.5 3x2.5 20.5 47.0 29.5 5x2.0 34.0 9.0 35.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 5x1.5 13.5 40.5 23. Armour .helkamabica. SHF2 .stranded copper conductor 16-300mm2  IEC 60228. cable size.2kV) DC 0. fax +358 2 237 2428.com . voltage. production month.0-10mm2   IEC 60228. class 5 (Flex) .6/1kV CABLES 10 LKSM-HF Armoured power and control cable 0. Sheath . coverage > 90% IEC 60092-350 .9/1. thermosetting polyolefine.tinned copper wire braid on request 5. +358 2 410 8700.filler tape 4. Conductor .tinned stranded copper conductor on request 2. Insulation .6/1kV (1. www. SHF1 IEC 60092-359 .5kV (if voltage to earth does not exceed 0. design 1.copper wire braid.polyolefine plastic.XLPE plastic IEC 60092-351 3. standards. temperature. cable type. Bedding .9kV) + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number. Main characteristics Rated voltage Maximum conductor temperature AC 0.on request. manufacturer's name and meter marking printed on the sheath Tel.0.standard colour black.stranded copper conductor 1. class 2 .6/1kV 5/2014 DESIGN: STANDARDS: IEC 60092-353. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. 1 3.5 14.0 18.8 39.0 12. 3G1.1 3.2 5.8 9.0 21.0 2x1.5 29.0 9.5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3x150 Flex 3x185 Flex 4.3 10.5 14.5 26.0 15.2 3.7 11.0 13.7 9.0 17.3 47.7 39.5 155 195 260 370 570 750 1165 1505 2100 2850 3685 4745 5885 7265 16 21 28 36 50 66 86 107 137 168 199 232 267 300 65 70 80 85 100 115 150 165 195 220 255 285 320 360 G-type is with yellow/green earth conductor and marking on sheath is.5 1x4 1x6 1x10 26237 26238 26239 26240 26241 26242 26243 26244 26245 26246 26247 27059 27061 27063 27065 27067 27069 27071 27073 27075 27077 27079 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 25956 25770 25785 25801 25803 25805 – – – – – – 2x1.0 14.0 22.9 5.5 14.6/1kV CABLES LKSM-HF 0.7 10.0 11.6/1kV .5 19.0 625 985 1240 1700 2270 80 105 130 167 204 110 140 155 180 205 – – 2x95 Flex 3x1.5 240 360 460 650 885 1115 1405 1720 2065 2715 3300 94 123 153 196 240 284 331 381 429 507 582 65 80 90 105 115 130 145 160 180 200 215 3.1 4.0 1x1.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2014 25955 25736 25738 25740 25742 25744 Crosssection of armour mm2 0.7 18.0 24.5 2965 130 241 13 235 60 25773 25787 25880 25882 25884 26272 26274 26276 26278 26280 26282 26284 26286 26288 3x1.0 23.6 3.3 22.0 22.0 14.5 8. for example.0 3.4 11.2 18.0 53.0 9.5 12.2 18.0 6. bending radius fixed installation mm 3.5 1x2.0 32.5 29.5 42.5 10.5 35.3 4.6 15.0 32.5 2x4 2x6 2x10 26254 26255 26256 26257 26258 – – – – – 26259 25957 25772 25786 25802 25804 25806 26271 26273 26275 26277 26279 26281 26283 26285 26287 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.0 16.5 2x2.0 36.5 27.5 14.4 8.7 14.8 4.5 13.9 5.0 47.1 18.0 9.6 5.0 19.7 15.7 18.5 7.5 110 130 160 210 315 480 15 20 26 34 44 61 55 60 65 75 80 95 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 10.0 25.0 3.9 10.5 70 75 90 105 130 190 18 23 30 40 52 72 40 40 45 45 50 60 4.5 6.0 59.5 23.8 37.1 4.5 34.0 7.5 8.1 3.11 Part number Normal G-type Number of conductors & cross-section n x mm2 – – – 27052 27054 27056 1x1.5 3x2. 5 1070 1655 55 71 140 180 25960 25961 25962 25963 25964 25965 25977 25978 25981 – – – – – – – – – 7x1.0 17.5 5x4 5x6 5x10 4.8 18.6 8.5 12.4 12.5 4x4 4x6 4x10 4.5 15. bending radius fixed installation mm 25958 25774 25788 25830 25832 25834 – 25775 25789 25831 25833 25835 4x1.0 29. www.0 150 180 240 320 475 695 13 16 21 28 36 50 65 70 75 85 95 110 26301 26303 26305 26307 26309 26311 26313 – 26302 26304 26306 26308 26310 26312 26314 – 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 4x120 Flex 4x150 Flex 11.5 15.8 14.5 40.0 11.5/2014 0.0 4.0 5x1.0 175 220 285 410 565 830 10 13 17 23 30 42 65 75 80 95 105 120 26331 26333 26332 26334 5x16 Flex 5x25 Flex 13.0 24x1.5 4x2.8 10.com .6 37.0 16x1.8 39.9 14.0 5.5 18.5 10.helkamabica.5 215 320 350 385 445 490 610 655 840 9 8 8 7 7 7 6 6 5 75 90 95 100 105 110 125 130 145 G-type is with yellow/green earth conductor and marking on sheath is.7 9. +358 2 410 8700.3 10.3 48. fax +358 2 237 2428.5 22.0 47.0 12x1.5 5.5 35.5 15.8 8.5 21.0 23.9 8.0 9.0 20.0 16.2 18.5 12.0 19x1.0 17.0 4x1.6/1kV Part number Normal G-type Number of conductors & cross-section n x mm2 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.0 14x1. for example.0 27.0 12.6/1kV CABLES 12 LKSM-HF 0.5 5x2.2 21.7 11.4 11.1 23.0 945 1440 1900 2635 3590 4850 6010 7565 66 86 107 137 168 199 232 267 130 165 180 215 245 285 315 355 25959 25776 25790 26011 26013 26015 – 25777 25791 26012 26014 26016 5x1.0 37x1.1 4.0 13.0 17.5 20.5 5.0 27x1.0 5.4 11.0 15.0 10x1. 3G16 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page Tel.4 11.6 9.0 29.0 52.0 59.1 19.5 13. 5 5.0 20.6 9.5 26.0 19.9 14.5 24x2.5 10x2.5 7x2.5 11.5 23.5 13.5 19x2.5 21.5 24.5 11.0 19.5 16x1. for example.8 12.0 18.9 10.5 37x1. bending radius fixed installation mm 80 100 105 110 115 120 140 145 160 90 115 115 125 130 135 160 165 5/2014 25778 26025 25780 26027 26030 25782 25828 25783 25784 25792 26033 25794 26035 26037 25796 25798 25768 Number of conductors & cross-section n x mm2 0.7 16.4 9.6/1kV .1 16.5 12x1.7 13.5 17.5 27x2.6/1kV CABLES LKSM-HF 0.0 8.0 16.5 11.2 15.5 14x1.0 Approximate weight kg/km 265 390 440 490 545 610 780 845 1085 380 535 595 680 760 855 1080 1175 Current Rating A at +45°C 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 G-type is with yellow/green earth conductor and marking on sheath is.5 24x1.5 10x1.0 18.5 22.1 Nominal outer diameter mm 13.5 16x2.5 11.5 12x2.13 Part number Normal G-type 25779 26026 25846 26028 26029 25781 25829 25847 25848 25793 26034 25795 26036 26038 25797 25799 25769 Crosssection of armour mm2 7x1.5 27x1. 3G16 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Min.5 15.5 11.5 14x2.0 26.0 27.5 19x1.5 19. XLPE plastic IEC 60092-351 3. www. SHF1 IEC 60092-359 .2kV) DC 0. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. coverage > 90% IEC 60092-350 . voltage. +358 2 410 8700.on request.standard colour black.polyolefine plastic. temperature.9/1.copper wire braid. fax +358 2 237 2428. Armour .0.6/1kV CABLES 14 LKMSM-HF 5/2014 DESIGN: Armoured power cable with extruded filler 0. design 1. cable type. manufacturer's name and meter marking printed on the sheath Tel.tinned copper wire braid and galvanized steel wire braid on request 5. thermosetting polyolefine. production month.5–10mm2 IEC 60228.stranded copper conductor 1.stranded copper conductor 16–150mm2 IEC 60228. Bedding . Conductor .9kV) + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. SHF2 . standards. cable size. class 5 . Insulation .5kV (if voltage to earth does not exceed 0. Main characteristics Rated voltage Maximum conductor temperature AC 0.6/1kV (1.helkamabica.6/1kV STANDARDS: IEC 60092-353.extruded filler 4.tinned stranded copper conductor on request 2. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number. class 2 .com . Sheath . 1 10.0 195 230 290 425 580 740 1085 1400 1895 220 275 345 495 685 885 1320 1710 2345 3200 4270 5235 6610 260 320 430 590 830 1085 1605 2105 2875 4120 5245 6575 300 395 510 690 985 1300 1925 20 26 34 44 61 80 105 130 167 16 21 28 36 50 66 86 107 137 168 199 232 267 16 21 28 36 50 66 86 107 137 168 199 232 13 17 23 30 42 55 71 70 75 85 90 105 120 145 160 190 75 80 85 95 110 125 155 170 200 230 270 295 335 80 85 95 105 120 140 170 190 220 260 295 330 85 95 105 115 130 152 185 G-type is with yellow/green earth conductor and marking on sheath is.0 15.5 33.8 51.4 15.5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 3x1.0 22.9 5.4 40.0 14.2 10.6/1kV .5 27.0 49.5 37.6 6.2 16.5 20.6 12. for example.0 23.5 16.0 13.0 14.5 12.5 3x2.4 9.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 5x1.0 26.0 43.0 55.9 25.1 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.0 31.0 15.0 9. 3G1.5 20.5 14.5 21.6/1kV CABLES LKMSM-HF 0.1 20.5 10. bending radius fixed installation mm 11.0 49.7 12.7 5.5 18.0 16.5 31.5 17.5 13.5 14.5 38.5 2x2.3 9.2 5.5 17.6 44.5 5x2.4 18.0 18.2 24.0 17.7 11.0 24.5 31.5 45.5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 4x1.0 19.0 20.2 20.0 28.0 55.0 51.0 25.15 Part number Normal G-type – – – – – – – – – 27266 27270 27274 27278 27282 27287 27291 27295 27299 27303 27307 27311 27315 27330 27334 27338 27342 27346 27351 27355 27359 27363 27367 27371 27375 27394 27398 27402 27406 27410 27415 27419 2x1.0 12.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 27232 27234 27236 27238 27240 27243 27245 27247 27249 27264 27268 27272 27276 27280 27285 27289 27293 27297 27301 27305 27309 27313 27328 27332 27336 27340 27344 27349 27353 27357 27361 27365 27369 27373 27392 27396 27400 27404 27408 27413 27417 Number of conductors & cross-section n x mm2 0.2 21.5 4x2.4 6.5 5x4 5x6 5x10 5x16 5x25 Crosssection of armour mm2 4.8 16.1 45.4 11.4 17.7 45.8 13.7 6.0 28.1 9.2 6.5 14.1 5.4 13. Insulation .drain wire of tinned copper 1. SHF2 .6/1kV (1. cable size. IEC 60092-350 coverage 100% 4. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number. www.com . class 2 .0mm2 (in all sizes) . Main characteristics Rated voltage AC 0. thermosetting polyolefine.polyolefine plastic. production month. SHF1 IEC 60092-359 .stranded copper conductor IEC 60228. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. Conductor . design 1. temperature.helkamabica. standards.standard colour black.6/1kV CABLES 16 LKAM-HF Screened power and control cable 0. +358 2 410 8700.5kV (if voltage to earth does not exceed 0.on request. voltage.aluminium polyester tape. Sheath .tinned stranded copper conductor on request 5/2014 2. especially when lightweight cables are needed.XLPE plastic IEC 60092-351 3.9/1.0. manufacturer's name and meter marking printed on the sheath Tel.2kV) DC 0.9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. cable type. Screen .6/1kV DESIGN: STANDARDS: IEC 60092-353. fax +358 2 237 2428. 5 25.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 27102 27106 27110 27114 27118 27140 27122 27144 27148 27126 27130 27134 27155 27136 27104 27108 27112 27116 27120 27142 27124 27146 27150 27128 27132 27138 27157 27152 Number of conductors & cross-section n x mm2 0.5 10x1.0 25.0 9.5 37x2.0 9.5 32x2.5 16x1.5 5x2.6/1kV .5 4x2.5 3x2.5 2x2.5 9.5 10.5 24x2.5 4x1.5 7x1.5 22.5 19x1.0 16.5 18.5 11.5 21.5 100 125 150 175 220 310 350 395 450 510 650 710 825 935 130 160 195 240 300 430 495 565 635 740 930 1025 1195 1355 20 16 16 13 12 11 10 10 9 9 8 8 7 7 26 21 21 17 16 14 13 13 12 11 10 10 9 9 55 55 60 65 70 90 95 100 105 110 130 135 140 150 60 60 65 75 80 105 105 110 120 125 150 150 160 170 G-type is with yellow/green earth conductor and marking on sheath is.0 15.5 19.5 14x2.0 12.0 18.5 23.5 28.0 22.5 3x1.5 7x2.6/1kV CABLES LKAM-HF 0. bending radius fixed installation mm 2x1.0 11.5 16x2. for example.5 13.5 32x1.17 Part number Normal G-type – 27107 27111 27115 27119 27141 27123 27145 27149 27127 27131 27135 27156 27137 – 27109 27113 27117 27121 27143 27125 27147 27151 27129 27133 27139 27158 27153 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.5 12x2.5 5x1.5 24x1.5 18.5 10.0 25. 3G1.5 14x1.5 37x1.5 16.5 19x2.5 27x2.0 12.5 17.5 26.5 27x1.5 10x2.5 12x1.5 17. helkamabica. SHF2 Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed wiring in switchboards.stranded flexible copper conductor Switchboard wire 0.on request.5kV (if voltage to earth does not exceed 0.9/1. design IEC 60228. Main characteristics Rated voltage AC 0. cable size. voltage and manufacturer's name Tel. +358 2 410 8700. fax +358 2 237 2428. other colours on request .6/1kV STANDARDS: IEC 60092-353. control panels and other enclosures. www.2kV) DC 0. Conductor .9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series -test for single insulated wire and cable Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Cable type. oil resistant thermosetting polyolefine.0.com .HF90 plastic IEC 60092-351 .standard colour black.6/1kV (1. class 5 2. Insulation .6/1kV CABLES 18 LKEM-HF DESIGN: 5/2014 1. yellow/green.3 26.6 4.75 mm2.7 16. 1 mm2. grey.5 mm2.5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 2.7 11.7 5.19 Part number Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.1 4.5 mm2 and 2.8 3.5 1x0.5 1x2.1 3.2 18.3 2.6/1kV CABLES LKEM-HF 0. dark blue. bending radius fixed installation mm 1x0. orange. 0.9 13. brown. violet and white Other colours on request   Delivery lengths: 0.7 8.75 1x1. red. 1.6/1kV . yellow. black.8 28.6 9.7 2.2 20.0 1x1.9 10 14 17 21 32 45 63 103 154 244 334 476 671 887 1125 1424 1753 2357 2900 11 14 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582 10 15 15 15 15 20 20 25 30 35 40 50 55 65 75 85 95 110 120 * Rated voltage 300/500V Available in colours: blue. green.7 6.8 23.5 mm2 available in 200 m boxes or 500 m drums 4 mm2 available in 100 m boxes or 500 m drums 6 mm2 and 10 mm2 available in 100 m coils or 500 m drums Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 25117* 25120 25121 25122 25124 25125 25126 25128 25130 25132 25134 25136 25138 25165 25166 25279 25281 25283 25285 Number of conductors & cross-section n x mm2 0. Screen . Bedding .tinned copper wire braid on request 6.9/1. SHF2 .6/1kV 5/2014 DESIGN: STANDARDS: IEC 60092-353.polyolefine plastic. Main characteristics Rated voltage AC 0.0-10mm 2 IEC 60228. cable size. fax +358 2 237 2428. Conductor 2 -stranded copper conductor 1.XLPE plastic IEC 60092-351 3.standard colour black. Identification: Lot number.copper tape.5kV (if voltage to earth does not exceed 0. standards. coverage > 90% IEC 60092-350 . SHF1 IEC 60092-359 . production month. Design to meet requirements for improved EMC screening properties.6/1kV (1. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section. thermosetting polyolefine.on request. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. Armour .2kV) DC 0.helkamabica. design 1.filler tape 4. class 5 . coverage 100% 5. Sheath .EMC CABLES 20 LKSM-EMC Armoured power and control cable with improved EMC screening 0.com . +358 2 410 8700.tinned stranded copper conductor on request 2.copper wire braid. cable type. manufacturer's name and meter marking printed on the sheath Tel. voltage. temperature. Insulation . www.9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. class 2 -stranded copper conductor 16-300mm IEC 60228. 5 10.5 23.1 18.0 13.0 8.5 29.6 4.0 8.6 5.0 3.5 11.5 2x2.5 20.0 34.5 1x2.0 4.5 34.5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 4.5 15.0 6.3 3.0 6.0 2x1.0 26.0 3.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Crosssection of armour mm2 3.0 18.5 14.5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 2x1.5 7.7 16.0 25.0 10.1 3.0 21.4 18.3 17.1 4.5 26.0 19.3 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C 6.8 10.5 11.5 14.0 23.0 29.5 7.0 39.3 4. bending radius fixed installation mm 37 39 41 45 48 57 66 80 86 102 114 129 143 160 176 197 213 56 59 65 72 79 95 112 138 153 179 204 235 Table continues on next page 5/2014 26904 27513 27514 27515 27516 27517 27518 27519 27520 27521 27522 27523 27524 27525 27526 27527 27528 26905 27480 27481 27482 27483 27484 27485 27486 27487 27529 27530 27531 Number of conductors & cross-section n x mm2 EMC CABLES LKSM-EMC 0.5 19.0 90 100 110 130 155 230 280 405 515 705 940 1185 1465 1815 2165 2795 3425 130 145 180 250 340 535 725 1045 1325 1785 2385 3100 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241 Min.0 9.8 3.0 9.6/1kV .5 12.0 6.5 17.4 14.6 8.0 13.2 4.5 8.4 14.0 3.0 11.0 12.5 10.0 16.0 25.5 21.9 5.5 11.5 24.8 21.1 8.0 35.5 30.0 7.5 29.0 7.21 Part number Normal G-type Diameter of screen mm 1x1.0 11.5 9.1 3.5 33.7 15.0 4.5 5.4 12.5 12.0 31.0 1x1.0 18.0 16. 0 46.5 18.5 19.5 27.5 5x2.5 15.3 11.9 5.4 3.6 22.5 14. fax +358 2 237 2428.0 12.5 12.7 5.0 13.5 42.5 11. +358 2 410 8700.2 4.3 22.5 16.5 14.5 12.0 27. www.2 18.0 5x1.3 11.8 18.0 13.5 15.0 10.3 16.0 25.0 47.5 22.9 4.0 8.5 11.0 7.5 17.5 13.5 47.3 5.5 29.0 16.5 59.5 52.5 40.0 41.0 14.0 11.5 155 175 215 285 395 630 835 1245 1590 2205 2970 3825 4895 6060 175 200 260 340 505 750 1020 1510 1970 2715 3675 4935 6095 7610 200 240 305 460 615 875 1220 1775 13 16 21 28 36 50 66 86 107 137 168 199 232 267 13 16 21 28 36 50 66 86 107 137 168 199 232 267 10 13 17 23 30 42 55 71 Min.0 53.9 37.9 39.3 4.5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 4x1.0 23.0 22.0 25.5 15.5 4x2.0 27.9 39.6/1kV 5/2014 Part number Normal G-type 26906 26861 26863 26865 26867 26869 26872 26874 26876 26878 26880 26882 26884 26886 26907 26942 26944 26946 26948 26950 26952 26954 26956 26958 26960 26962 26964 26966 26908 27488 27489 27490 27491 27492 27493 27494 26988 26862 26864 26866 26868 26870 26851 26852 26853 26854 26855 26856 26857 26858 26989 26943 26945 26947 26949 26951 26953 26955 26957 26959 26961 26963 26965 26967 26990 27838 27839 27940 27941 27942 27943 27944 Number of conductors & cross-section n x mm2 Diameter of screen mm 3x1.4 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C 10.5 8.0 12.5 11.5 9.5 31.0 20.7 4.0 12.5 8.5 8.0 35.5 3x2.0 16.0 11.5 8.0 3x1.9 14.5 24.5 9.4 43.0 30.0 35.0 13.0 5.EMC CABLES 22 LKSM-EMC 0.5 20.5 10.5 5x4 5x6 5x10 5x16 5x25 7.6 3.0 10.9 4.0 36.6 15.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 5x1.5 9.0 18.5 21.4 11.0 37.0 23.5 42.5 10.helkamabica.0 32.5 52. bending radius fixed installation mm 59 62 68 76 84 100 118 147 162 193 219 252 283 319 63 67 74 82 94 110 131 161 179 213 241 284 314 355 67 73 80 92 102 120 142 177 Table continues on next page Tel.com .5 32.0 4x1.9 10.0 23.0 47.9 12.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Crosssection of armour mm2 3.2 19.6 8.6 37. 5 27x2.0 7x1.0 14x1.0 15.0 13. bending radius fixed installation mm 74 93 96 100 105 111 130 132 147 78 99 102 108 113 119 139 143 160 87 111 115 120 128 135 157 161 5/2014 26909 26910 26911 26912 26913 26914 26915 26916 26917 27495 27497 27499 27501 27503 27505 27507 27509 27511 27496 27498 27500 27502 27504 27506 27508 27510 Number of conductors & cross-section n x mm2 EMC CABLES LKSM-EMC 0.0 10.0 19.5 11.0 12x1.5 19x1.5 21.5 37x1.6 13.0 13.0 22.7 5.2 10.5 24x1.5 16x1.0 27.8 11.0 26.7 9.5 9.0 18.0 10x1.5 19x2.0 24x1.8 Nominal outer diameter mm Approximate weight kg/km 12.5 15.5 23.0 24.2 12.0 18.6/1kV .0 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Crosssection of armour mm2 4.5 15.3 15.9 10.5 26.5 19.5 18.4 13.5 14x2.0 17.5 16.5 7x2.0 20.0 21.5 20.5 12x1.5 22.5 11.5 13.5 17.5 22.5 14.8 11.9 15.0 23.9 9.5 13.9 15.5 14.1 5.5 19.5 14.4 11.2 12.5 10x2.2 10.0 20.5 17.5 27x1.9 9.5 18.5 12.5 14.2 12.0 16.5 16.5 24x2.5 12x2.0 10.2 9.0 24.5 12.0 240 365 395 430 465 550 695 750 935 285 420 465 520 570 675 855 930 1175 365 555 620 690 775 910 1145 1250 Current Rating A at +45°C 9 8 8 7 7 7 6 6 5 23 20 16 16 13 23 20 16 23 30 26 21 21 17 30 26 21 Min.0 19x1.0 15.5 10x1.0 37x1.0 27x1.0 18.5 20.0 16.0 19.5 10.23 Part number Normal G-type 26991 26992 26993 26994 26995 26996 26997 26998 26999 27840 27842 27844 27846 27848 27850 27852 27854 27856 27841 27843 27845 27847 27849 27851 27853 27855 Diameter of screen mm 7x1.0 22.5 15.0 16x1.0 18.5 16.5 14x1.5 16x2. copper wire braid.filler tape emission 4. cable size. voltage.6/1kV (1. Main characteristics Rated voltage AC 0.tinned copper wire braid on request 6. class 2 Flame-stranded copper conductor 16-300mm IEC 60228. temperature. standard colour orange IEC 60092-359 .2kV) DC 0.polyolefine plastic. standards. Conductor 2 -stranded copper conductor 1. SHF2.copper tape. Design to meet requirements for improved EMC screening properties.0-10mm 2 IEC 60228. www.Mica tape Halogen.on request thermosetting polyolefine. coverage 100% (only SHF2) 5.other colours on request Application: For fixed installation in all areas and on open deck in ships. category A Fire -resistant IEC 60331-1 and IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section.6/1kV STANDARDS: IEC 60092-353. SHF1. Armour . cable type. Insulation resistant . production month.helkamabica.tinned stranded copper conductor on request Fire2.9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. If the cable is exposed to direct sun light protective covering or cable with black outer shetah is recommended.EMC CABLES 24 LKSM-EMC-FRHF 5/2014 DESIGN: Fire-resistant armoured power and control cable with improved EMC screening 0.5kV (if voltage to earth does not exceed 0. fax +358 2 237 2428. class 5 retardant .com .9/1. Identification: Lot number. Bedding Low smoke .XLPE plastic IEC 60092-351 free 3. +358 2 410 8700. design 1. Screen Oil resistant . manufacturer's name and meter marking printed on the sheath Tel. coverage > 90% IEC 60092-350 . standard colour black . Sheath . bending radius fixed installation mm 6.0 31.0 7.5 25.0 30.5 9.5 35.5 155 210 260 325 505 665 900 1335 1695 2285 3060 4160 5010 6210 13 16 21 28 36 50 66 86 107 137 168 199 232 267 60 70 75 80 90 105 125 155 170 200 225 265 290 325 – 27897 27898 27899 27900 27905 27906 27907 27908 27909 27910 27912 27913 – 4x1.5 105 115 125 145 170 230 285 410 515 705 945 1195 1475 1820 2175 2800 3430 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 35 40 45 45 50 60 65 80 85 100 115 130 140 160 175 195 210 Table continues on next page 5/2014 1x1.5 8.4 23.7 14.5 12.0 11.1 3.5 1x2.7 11.0 48.5 20.5 190 250 305 445 570 805 1105 1620 2105 2840 3830 5060 6260 7790 13 16 21 28 36 50 66 86 107 137 168 199 232 267 65 75 80 90 100 115 140 170 185 220 250 290 320 365 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.5 26.3 40.5 10.5 53.5 12.5 2x2.0 2x1.5 13.6 5.7 15.0 10.0 16.5 16.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 3.5 13.0 19.0 18.0 1x1.25 – 27872 27873 27874 27875 27876 27877 27878 27879 27880 27881 – 2x1.1 21.5 44.5 28.0 37.7 15.0 3.0 8.3 20.5 19.5 29.5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 Part number Number of conductors & cross-section n x mm2 EMC CABLES – – – – – – – – – – – – – – – – – Crosssection of armour mm2 3.3 10.4 45.9 5.5 19.5 23.5 15.7 LKSM-EMC-FRHF 0.6 18.8 12.0 3x1.5 48.0 4x1.6 14.0 135 165 190 270 390 570 745 1075 1355 1830 2435 3170 15 20 26 34 44 61 80 105 130 167 204 241 55 65 70 80 85 100 115 140 155 180 205 240 – 27882 27883 27884 27885 27886 27887 27888 27889 27890 27891 27892 27893 27894 3x1.9 18.3 9.5 11.1 5.5 10.0 23.0 3.3 4.5 17.5 17.0 36.0 34.9 11.5 22.1 4.1 3.6/1kV .7 9.0 11.5 60.5 4x2.3 9.5 8.0 28.0 11.5 11.2 38.5 23.0 33.5 12.0 54.0 14.5 40.4 12.0 7.3 14.2 10.9 15.0 14.9 5.5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 3.5 15.1 4.9 5.5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3.4 4.9 4.5 26.5 4.7 19.2 43.3 40.6 4.0 13.5 11.6 9.0 32.2 17.5 3x2.5 13.4 38.1 3.5 41.0 21.8 16. 5 22.6 20.5 24x2.2 16.3 – – – – – – – – – – 7x1.4 11.0 21.9 18.1 15.6/1kV 5/2014 Part number Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.0 29.helkamabica.0 20.4 12.5 19x1.0 27.5 10x2.0 17.5 9. www.5 23.4 13.5 16x2.5 460 630 705 785 875 985 1245 1375 1490 1770 16 14 13 12 12 11 10 10 10 9 95 125 130 135 140 150 175 180 185 200 LKSM-EMC-FRHF 0.0 16x1.0 10x1.1 10.5 22. fax +358 2 237 2428.9 16.com .7 13.3 11.5 5x2.8 14.5 18.5 37x2.0 5.5 14x1.0 21.5 250 360 405 440 480 550 690 735 795 930 9 8 8 7 7 7 6 6 6 5 75 95 95 100 105 110 130 135 135 150 27921 27923 27925 27927 27929 27931 27933 27935 – 27937 7x1.1 17.5 25.0 23.0 17.0 11.0 33.4 12.5 12x1.0 30x1.5 5x4 5x6 5x10 5x16 5x25 Crosssection of armour mm2 4.5 21.5 14.5 22. bending radius fixed installation mm 11.5 18.3 5.5 37x1.0 24.4 11.5 26.4 11.0 11.9 10.5 25.5 13.5 27x1.5 14x2.6 17.0 400 485 535 590 675 750 945 1030 1110 1315 12 11 10 10 9 9 8 8 7 7 90 110 115 120 130 135 155 160 165 180 27922 27924 27926 27928 27930 27932 27934 27936 – 27938 7x2.5 10x1.0 37x1.5 15.5 17.9 14.9 9.0 21.5 19.5 220 290 415 525 685 975 1320 1880 10 13 17 23 30 42 55 71 70 80 90 100 110 130 150 185 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Tel.5 11.6 15.0 19x1.0 16.0 18.5 19x2.0 30.0 12x1.0 27x1.4 12. +358 2 410 8700.0 15.6 11.5 21.5 30x1.0 27.5 16.5 18.2 8.5 12x2.5 30x2.3 13.0 14x1.0 24x1.5 24x1.0 13.8 12.EMC CABLES 26 – 27914 27915 27916 27917 27918 27919 27920 5x1.2 14.5 15.0 30.5 27x2.5 16x1.5 30.3 11.0 5x1.7 12.0 31. 27 EMC CABLES 5/2014 . two insulated cores twisted together to form a pair See next page for Quad 4. Bedding . production month. Sheath . design 1.4 60 0.on request. voltage. class 2 .XLPE plastic IEC 60092-351 3. Insulation resistance / +20°C (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) 0.5mm2 0.6 0. coverage >94% EC 60092-350 . cable size. nom. fax +358 2 237 2428. Twisted pair .standard colour grey. SHF2 . / +20°C Pair capacitance.tinned stranded copper conductor on request 2.6 ≥1500 ≥1500 1. +358 2 410 8700. Conductor .helkamabica. manufacturer's name and meter marking printed on the sheath Tel.drain wire copper (in all sizes) . category A IEC 60754 series IEC 61034 series Transfer impedance IEC 61196-1 Electrical data: Loop resistance of pair. Screen .polyolefine plastic.filler tape 5. cable type. temperature. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Armour . standards. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) Halogen-free Smoke emission + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables.7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section Identification: Lot number. thermosetting polyolefine. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships.com . / 800Hz Loop inductance.5mm2 24. max.tinned copper wire braid on request 7. SHF1 EC 60092-359 .copper wire braid. nom. Design to meet requirements for improved EMC screening properties. Insulation .copper tape 100% 6.75mm2 80 52 55 50 0. www.EMC CABLES 28 RFE-EMC Armoured instrumentation and communication cable with improved EMC screening 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376.stranded copper conductor IEC 60228. 29 Part number 1x2x0.75 1x2x1.5 Quad 2x2x1.5 19x2x0.5 16.75 19x2x0.0 10.5 35.5 22.5 24x2x1.5 21.0 27.5 26.75 30x2x0.5 29.5 23.5 31.5 10x2x1.5 18.0 20.0 19.5 12x2x1.5 22.5 4x2x1.5 37.5 18.75 7x2x0.5 1x3x0.0 15.75 24x2x0.0 17.75 14x2x0. bending radius fixed installation mm 7.75 8x2x0.75 3x2x0.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Nominal outer diameter mm Approximate weight kg/km Min.5 32x2x0.5 8x2x0.0 13.75 2x2x0.5 1x3x1.5 11.5 13.5 16.5 2x2x1.5 19x2x1.5 12x2x0.0 8.5 24.5 30x2x0.5 26.5 27x2x1.75 12x2x0.5 29.75 32x2x0.0 10.0 11.0 20.0 27.5 9.75 16x2x0.5 10x2x0.5 14x2x0.5 4x2x0.5 32x2x1.5 37x2x0.0 43.75 27x2x0.5 7x2x1.0 7.5 27x2x0.5 15.5 10.75 1x3x0.0 7.5 15.75 Quad 2x2x0.5 19.5 14.0 11.75 37x2x0.5 2x2x0.5 31.5 1x2x0.5 3x2x0.0 8.0 9.5 16x2x1.5 7x2x0.0 28.0 11.75 4x2x0.0 23.5 3x2x1.0 13.0 24.5 14x2x1.5 26.5 Quad 2x2x0.5 95 105 115 150 165 185 270 290 365 395 445 480 540 655 710 775 810 900 110 130 150 175 200 255 365 400 475 520 600 655 755 900 980 1060 1140 1270 165 210 220 285 335 425 605 690 820 935 1045 1175 1335 1650 1810 1985 2090 2490 40 45 45 60 60 65 75 80 95 95 105 110 115 130 135 140 145 155 45 50 55 65 70 75 95 100 110 115 125 130 140 155 165 170 175 185 60 65 70 85 90 100 120 130 150 155 165 175 190 210 220 235 240 260 5/2014 21968 21969 21970 21971 21972 21973 21974 21975 21976 21977 21978 21979 21980 21981 21982 21983 21984 21985 21987 21988 21989 21990 21991 21992 21993 21994 21995 21996 21997 21998 21999 22000 22001 22002 22003 22004 22375 22376 22377 22378 22379 22380 22381 22382 22383 22384 22385 22386 22387 22388 22389 22390 22391 22392 Number of conductors & cross-section n x mm2 EMC CABLES RFE-EMC 250V .5 22.5 37x2x1.5 16x2x0.5 8x2x1.0 40.5 30x2x1.0 39.75 10x2x0.5 24x2x0.0 17. on request. manufacturer's name and meter marking printed on the sheath Tel.XLPE plastic IEC 60092-351 3.5mm2 0. Design to meet requirements for improved EMC screening properties.stranded copper conductor IEC 60228. thermosetting polyolefine. Screen . other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships.75mm2 80 52 55 70 0. Bedding .drain wire copper (in all sizes) . design 1.5mm2 24. cable size.tinned stranded copper conductor on request 2. fax +358 2 237 2428. cable type. nom.filler tape 5.6 0. / 800Hz Loop inductance.EMC CABLES 30 RFE-EMC(i) Armoured and pair screened instrumentation and communication cable with improved EMC screening 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376. nom. Armour .standard colour grey. Conductor . If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.copper tape 100% 6.7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section Identification: Lot number. max.tinned copper wire braid on request 7.two insulated cores twisted together to form a pair .helkamabica.plastic coated aluminium tape and a tinned copper drain wire 4.4 90 0.copper wire braid. / +20°C Pair capacitance. Insulation resistance / +20°C (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) 0. coverage >94% IEC 60092-350 . Twisted pair & pair screen . SHF2 . class 2 . temperature. category A IEC 60754 series IEC 61034 series Transfer impedance IEC 61196-1 Electrical data: Loop resistance of pair.com .6 ≥1500 ≥1500 1. voltage. Sheath . production month. Insulation . standards. SHF1 EC 60092-359 . www.polyolefine plastic. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) Halogen-free Smoke emission + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. +358 2 410 8700. 75 12x2x0.75 16x2x0.0 29.5 17.5 16x2x1.5 16.0 16.75 24x2x0.5 10x2x1.5 24x2x1.0 22.5 37x2x0.5 7x2x0.0 14.0 13.5 10.0 7.5 32x2x0.75 14x2x0.5 1x3x1.0 11.0 22.0 24.0 9. bending radius fixed installation mm 1x2x0.75 4x2x0.0 10.75 7x2x0.75 10x2x0.0 25.5 16.5 30x2x1.75 1x3x0.5 40.75 30x2x0.0 25.5 12x2x1.75 3x2x0.0 44.0 36.5 1x3x0.75 19x2x0.5 8x2x1.0 23.5 19x2x1.31 Part number Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Min.5 4x2x0.5 10.5 19.0 7.5 3x2x0.5 11.0 37.5 14.5 7x2x1.5 24.5 24x2x0.75 7.5 12x2x0.5 28.0 29.0 10.0 11.75 2x2x0.0 160 190 220 280 370 440 645 730 890 1005 1150 1275 1490 1835 2015 2235 2450 2780 60 65 70 85 95 105 125 135 150 155 170 180 195 215 225 240 245 265 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 21949 21950 21951 21952 21953 21954 21955 21956 21957 21958 21959 21960 21961 21962 21963 21964 21965 21966 EMC CABLES RFE-EMC(i) 250V .5 10x2x0.5 27x2x0.5 12.0 32.0 28.5 2x2x1.0 26.5 18.5 14x2x1.75 32x2x0.5 37x2x1.5 32x2x1.0 15.75 37x2x0.0 21.0 13.5 27x2x1.5 2x2x0.5 30x2x0.5 3x2x1.5 22.5 7.75 1x4x0.75 8x2x0.5 16x2x0.0 30.0 20.0 105 115 150 185 215 255 390 435 530 590 660 740 840 1040 1135 1230 1310 1465 45 50 55 70 70 75 95 100 115 120 125 135 145 160 165 175 180 190 21930 21931 21932 21933 21934 21935 21936 21937 21938 21939 21940 21941 21942 21943 21944 21945 21946 21947 1x2x1.0 41.5 4x2x1.0 26.0 17.5 14x2x0.5 8.5 8x2x0.5 20.0 16.0 26.75 27x2x0.0 20.5 1x4x1.5 32.5 19x2x0.5 1x4x0.5 90 100 120 150 175 205 300 360 430 490 540 590 690 835 910 990 1050 1180 40 45 45 60 60 65 80 85 95 100 105 110 120 135 140 145 150 160 21911 21912 21913 21914 21915 21916 21917 21918 21919 21920 21921 21922 21923 21924 21925 21926 21927 21928 1x2x0. Design to meet requirements for Variable Frequency Drivers (VFD). fax +358 2 237 2428. Insulation . thermosetting polyolefine.stranded copper conductor IEC 60228.XLPE plastic IEC 60092-351 3. manufacturer's name and meter marking printed on the sheath Tel.8/3kV CABLES 32 LKSM-VFD Armoured power and control cable with improved EMC screening 1. Cable with yellow/green protective earth (PE) conductor on request Identification: Lot number. Armour . design 1. standards.com . other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) For details see general information section Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: See technical information section.1. Sheath .8/3kV 5/2014 DESIGN: STANDARDS: IEC 60092-353.8/3kV (3.tinned copper wire braid on request 6. temperature. coverage > 90% IEC 60092-350 . +358 2 410 8700.standard colour black. www.helkamabica.polyolefine plastic. coverage 100% 5.on request.tinned stranded copper conductor on request 2. Screen . SHF1 IEC 60092-359 . voltage.filler tape 4. production month. Suitable for voltage peaks up to 3kV.copper tape. cable type.copper wire braid. Bedding . cable size. SHF2 . Conductor . class 5 .6kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. Main characteristics Rated voltage 1. 5 29.4 38.6 42.0 20.8 17.0 60. Electrical installations in ships –Choice and installation of electrical cables) 2 = Three additional protective earth (PE) conductors.6 14.3 11.0 35.5 29.0 17.7 28.5 37.5 27.0 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.6 18.5 13.3 12.5 50.0 16. bending radius fixed installation mm 14.5 50.0 41.0 355 495 625 795 995 1280 1525 1830 2165 2800 3365 1165 1525 1910 2580 3395 4295 5200 6255 7475 4655 5755 6825 94 123 153 196 240 284 331 381 429 507 582 66 86 107 137 168 199 232 267 300 199 232 267 85 95 105 115 125 140 150 165 180 200 210 160 180 195 225 245 280 305 330 360 280 305 330 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx NOTE! 1) = Protective earth (PE) rules are not fulfilled.8/3kV .5 23.0 46.8/3kV CABLES LKSM-VFD 1. (PE rules.5 8.0 35.5 55.0 45. Protective earth (PE) rules are fulfilled.7 15.5 25.33 Part number 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x95+3x16 3x120+3x25 3x150+3x25 5.6 42.5 9. This according to IEC 60092-352.5 35.5 32.5 33.0 26. for cables over 16mm2 the PE-conductor have to be half of main conductor and min.9 16.0 46.8 35.4 16.4 38.5 55.0 19. Note 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 2) 2) 2) 5/2014 26920 26922 26924 26926 26928 26930 26932 26934 26936 26938 26940 26871 26873 26875 26877 26879 26881 26883 26885 26887 26893 26895 26897 Number of Crossconductors & section of cross-section armour n x mm2 mm2 1.9 18.3 10. 16mm2. www. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.Mica tape .on request thermosetting polyolefine. standards. Conductor .stranded copper conductor IEC 60228.6/1kV CABLES 34 LKM-FRHF DESIGN: Fire-resistant unarmoured power and control cable 0.XLPE plastic IEC 60092-351 5/2014 3. Insulation . cable size. Main characteristics Rated voltage AC 0.com .0. manufacturer's name and meter marking printed on the sheath Tel.9/1.helkamabica. category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number.9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. Sheath (only SHF2) .tinned stranded copper conductor on request 2.6/1kV STANDARDS: IEC 60092-353. cable type. fax +358 2 237 2428.2kV) DC 0.separator tape Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant 4. +358 2 410 8700. standard colour black . Bedding . class 2 (class 5 on request) . production month.other colours on request Application: For fixed installation in most areas and on open deck in ships. standard colour orange  IEC 60092-359 . SHF2. temperature.5kV (if voltage to earth does not exceed 0.6/1kV (1. design 1. SHF1. voltage.polyolefine plastic. 5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2014 28275 28100 28102 28104 28106 28108 29326 29327 29328 29329 29330 29331 29332 29333 29334 29335 29336 28276 28132 28134 28136 28138 28140 29343 29344 29345 29346 29347 29348 28278 28162 28164 28166 28168 28170 29366 29368 29370 29372 29374 29376 29378 Number of conductors & cross-section n x mm2 0.5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3x1.0 9.5 3x2.0 22.0 18.0 45.0 15. for example.5 8.5 9.6/1kV .5 11.5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1.0 17.0 3x1.0 17.0 2x1.5 14.5 40 45 60 80 100 150 200 310 405 560 775 1000 1255 1580 1920 2540 3105 75 90 125 165 260 385 530 805 1095 1525 2075 2775 95 115 160 220 330 485 675 1030 1400 1970 2720 3570 4500 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241 13 16 21 28 36 50 66 86 107 137 168 199 232 30 35 35 40 45 50 40 50 55 65 70 80 90 100 170 190 205 50 55 65 70 75 90 70 90 100 175 200 230 55 60 65 75 85 95 75 95 155 185 215 245 275 G-type is with yellow/green earth conductor and marking on sheath is.5 38.5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 5.5 6.5 23.0 1x1. bending radius fixed installation mm 1x1.0 9.5 32.6/1kV CABLES LKM-FRHF 0.0 13.0 28.5 5.5 11.0 30.5 2x2.0 15.0 26.5 20.5 13.0 16.5 9.0 27.5 31.5 35.5 8.0 41.5 7.0 33.0 12.35 Part number Normal G-type – – – – – – – – – – – – – – – – – – – – – – – – – – – – 28279 28163 28165 28167 28169 28171 29367 29369 29371 29373 29375 29377 29379 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. 3G1.5 12.5 21.0 6.5 1x2.0 10.5 24.0 25. 5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page Tel.0 15.5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 9.0 28.0 4x1.0 13.0 46.0 13.5/2014 0.5 19.5 28.helkamabica.0 11.5 31.6/1kV CABLES 36 LKM-FRHF 0. www.5 5x2. fax +358 2 237 2428.5 26.0 115 150 200 280 405 610 865 1330 1790 2530 3475 4615 150 185 240 345 505 750 1050 1640 2215 3120 13 16 21 28 36 50 66 86 107 137 168 199 10 13 17 23 30 42 55 71 89 114 60 65 75 80 90 105 85 155 175 210 235 275 65 70 80 90 100 115 95 175 195 230 G-type is with yellow/green earth conductor and marking on sheath is.5 11.5 38.5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 5x1.0 5x1.0 12.6/1kV Part number Normal G-type 28280 28182 28184 28186 28188 28190 29400 29402 29404 29406 29408 29410 28282 28212 28214 28501 28503 28505 29434 29436 29438 29440 28281 28183 28185 28187 28189 28191 29401 29403 29405 29407 29409 29411 28283 28213 28215 28502 28504 28506 29435 29437 29439 29441 Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.0 18.0 12.5 15. +358 2 410 8700.0 20.5 39.5 34.5 4x2.com . for example. bending radius fixed installation mm 4x1.5 22. 3G1.0 16. 5 16.5 19.0 15.0 27x1.6/1kV .5 23.5 24.5 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.5 16x2.0 16x1.5 21.0 27.5 18. bending radius fixed installation mm 12.5 20.0 13.0 14x1.0 7x1.0 14.0 28.5 14x2.5 19.0 12x1.0 16.0 19x1.5 7x2.5 12x2.5 28.6/1kV CABLES LKM-FRHF 0.5 37x1.5 27x2.5 37x2.0 37x1.5 19x1.5 14x1.5 18.37 Part number Normal G-type 28285 28287 28289 28291 28293 28295 28297 28299 28301 28217 28241 28221 28245 28249 28225 28229 28233 28235 28219 28243 28223 28247 28251 28227 28231 28237 28239 7x1.0 31.5 24x2.0 15.5 27x1.5 17.5 18.5 16x1.0 25.5 180 260 295 330 380 435 550 600 805 230 330 380 430 485 565 725 795 1050 315 450 510 590 670 765 995 1095 1450 9 8 8 7 7 7 6 6 5 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 9 70 90 95 100 105 110 130 130 150 80 100 105 110 115 125 145 150 170 90 110 115 125 130 135 165 170 190 G-type is with yellow/green earth conductor and marking on sheath is.5 12x1.0 24x1.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 28284 28286 28288 28290 28292 28294 28296 28298 28300 28216 28240 28220 28244 28248 28224 28228 28232 28234 28218 28242 28222 28246 28250 28226 28230 28236 28238 Number of conductors & cross-section n x mm2 0.5 25.5 20.5 10x1.5 19x2. 3G1.0 10x1.5 22.5 21. for example.5 17.5 24x1.5 10x2. Sheath . cable size. SHF1.separator tape 4. manufacturer's name and meter marking printed on the sheath Tel.0.5kV (if voltage to earth does not exceed 0.helkamabica. temperature. www.on request thermosetting polyolefine.2kV) DC 0.other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships.9/1. cable type.XLPE plastic EC 60092-351 5/2014 3. category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number. standards. Main characteristics Rated voltage AC 0. design 1.polyolefine plastic.tinned stranded copper conductor on request 2. standard colour orange  IEC 60092-359 .6/1kV (1.copper wire braid.tinned copper wire braid on request IEC 60092-350 5. SHF2.6/1kV STANDARDS: IEC 60092-353. fax +358 2 237 2428. class 2 (class 5 on request) . +358 2 410 8700.com . Insulation . coverage > 90% . voltage. standard colour black . Bedding .Mica tape . Conductor .6/1kV CABLES 38 LKSM-FRHF DESIGN: Fire-resistant armoured power and control cable 0. Armour .9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. production month.stranded copper conductor IEC 60228. 5 19.5 3x2.0 16.0 3.4 11.5 3x4 3x6 3x10 3x16 Flex 3x25 Flex 3x35 Flex 3x50 Flex 3x70 Flex 3x95 Flex 3x120 Flex 3.0 12.7 15.1 3.2 4.5 4.8 37.8 6.2 18.4 8.5 17.0 2x1.0 10.5 14.1 18.0 29.3 4.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Table continues on next page 5/2014 28541 28568 28570 28572 28574 28576 29060 29061 29062 29063 29064 29065 29066 29067 29068 29069 29070 28542 28602 28604 28606 28608 28610 29071 29072 29073 29074 29075 29076 28543 28622 28624 28626 28628 28630 29082 29084 29086 29088 29090 29092 29094 Number of conductors & cross-section n x mm2 0.5 11.6 15.1 4.5 10.7 22.5 33.5 43.5 19.1 4.5 3.5 20.6/1kV . bending radius fixed installation mm 1x1.7 14.1 5.5 14.8 9.0 27. 3G1.0 8.0 37.0 3x1.0 75 80 95 115 140 195 255 380 475 665 905 1135 1410 1745 2090 2735 3325 120 140 170 225 340 505 665 1035 1300 1765 2345 3045 145 170 210 280 400 595 800 1225 1570 2170 2935 3775 4840 18 23 30 40 52 72 94 123 153 196 240 284 331 381 429 507 582 15 20 26 34 44 61 80 105 130 167 204 241 13 16 21 28 36 50 66 86 107 137 168 199 232 40 40 45 45 50 60 70 85 90 105 120 135 150 165 180 200 215 60 65 70 75 85 100 115 145 160 185 210 245 60 65 75 80 90 105 125 155 170 200 225 260 290 G-type is with yellow/green earth conductor and marking on sheath is.0 17.39 Part number Normal G-type – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 28544 28623 28625 28627 28629 28631 29083 29085 29087 29089 29091 29093 29095 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.7 10.7 11.2 18.5 12.5 22.2 5.6 5.5 2x4 2x6 2x10 2x16 Flex 2x25 Flex 2x35 Flex 2x50 Flex 2x70 Flex 2x95 Flex 3x1.1 3.5 1x4 1x6 1x10 1x16 Flex 1x25 Flex 1x35 Flex 1x50 Flex 1x70 Flex 1x95 Flex 1x120 Flex 1x150 Flex 1x185 Flex 1x240 Flex 1x300 Flex 2x1.0 40.0 14.0 24.5 8.0 30.0 10.0 1x1.0 13.7 18.0 14.5 13.0 10.9 5.0 17.3 10.3 14.0 24.0 3.5 7.1 3.5 35.0 7.5 22.8 4.0 8.0 25.5 28.0 13.2 5.7 3. for example.5 11.0 22.5 1x2.0 33.0 26.0 36.0 48.0 11.6/1kV CABLES LKSM-FRHF 0.5 2x2.5 15. www.9 14.5 24x1.7 9.0 16x1. bending radius fixed installation mm 4.0 13.0 19.5 11.5 27x1.4 12.6 22.0 21.0 21.5 12.9 11.0 40.7 16.5 5.5 11.0 24x1.5 22.5 12.0 13.5 14.0 24.5 19x1.5 16.8 12.1 19.0 10x1.5 23.5 14.0 5x1.5 7x2.0 19x1.5 4x4 4x6 4x10 4x16 Flex 4x25 Flex 4x35 Flex 4x50 Flex 4x70 Flex 4x95 Flex 5x1.0 29.0 37x1.5 4x2. fax +358 2 237 2428.0 13.5 36.6 35. 3G1.5 16x2.0 30.4 11.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Tel.4 11.9 14.5 27x2.0 48.0 5.5 28.6/1kV Part number Normal G-type 28545 28642 28644 28646 28648 28650 29104 29106 29108 29110 29112 29114 28547 28662 28664 28705 28707 28709 29126 29128 29130 29132 28549 28551 28553 28555 28557 28559 28561 28563 28565 28666 28723 28670 28727 28731 28674 28678 28682 28684 28668 28725 28672 28729 28733 28676 28680 28686 28688 28546 28643 28645 28647 28649 28651 29105 29107 29109 29111 29113 29115 28548 28663 28665 28706 28708 28710 29127 29129 29131 29133 28550 28552 28554 28556 28558 28560 28562 28564 28566 28667 28724 28671 28728 28732 28675 28679 28683 28685 28669 28726 28673 28730 28734 28677 28681 28687 28689 Number of conductors & cross-section n x mm2 4x1.5 18.5 30.5 24.8 10.5 5.2 18.0 4x1.5 5x4 5x6 5x10 5x16 Flex 5x25 Flex 5x35 Flex 5x50 Flex 7x1.0 12.8 14.5 33.5 17.5 14x1.1 16.0 11.0 22.2 15.5 16.8 18.0 23.0 20.4 9.5/2014 0.5 5x2.4 11.5 29.1 11.5 29.5 24x2.3 11.0 26.7 13.helkamabica. +358 2 410 8700.0 4.5 12x2.6 9.5 37x2.0 5.com .0 27x1.0 8.9 8. for example.0 26.4 5.5 37x1.0 21.5 Crosssection of armour mm2 Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.5 10x2.5 12x1.5 16.0 22.5 13.1 18.5 10x1.5 24.6 9.6/1kV CABLES 40 LKSM-FRHF 0.7 11.0 20.0 18.5 22.5 13.1 18.6 8.7 8.0 16.0 26.5 34.0 12x1.5 11.0 19.5 19.0 170 200 255 335 505 725 1010 1515 1980 2730 3695 4935 195 245 305 440 600 870 1135 1735 2390 3330 240 355 395 455 505 555 695 750 960 295 430 490 555 610 680 875 945 1220 405 570 635 730 815 920 1165 1265 1660 13 16 21 28 36 50 66 86 107 137 168 199 10 13 17 23 30 42 55 71 89 114 9 8 8 7 7 7 6 6 5 12 11 10 10 9 9 8 8 7 16 14 13 13 12 11 10 10 9 65 70 80 90 100 115 135 170 185 220 250 290 70 80 85 100 110 125 150 185 205 245 80 100 100 105 115 120 140 145 160 85 110 115 120 125 130 155 160 180 95 120 125 135 140 145 175 175 200 G-type is with yellow/green earth conductor and marking on sheath is.5 19x2.5 14.4 4.5 18.5 14x2.0 14x1.0 7x1.5 16x1.0 20.1 4.5 11.5 41. 41 0.6/1kV CABLES 5/2014 . SHF2. SHF1.0mm2 (in all sizes) . Insulation .Mica tape . +358 2 410 8700. design 1. Sheath .XLPE plastic IEC 60092-351 5/2014 3. www. Screen . temperature. IEC 60092-350 coverage 100% Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 4.on request thermosetting polyolefine.other colours on request Application: For fixed installation in most areas and on open deck in ships. production month. fax +358 2 237 2428.drain wire of tinned copper 1. cable size. standards.tinned stranded copper conductor on request 2. Conductor . standard colour black . standard colour orange  IEC 60092-359 .polyolefine plastic. category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: see technical information section Identification: Lot number. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.9kV) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables.6/1kV (1.6/1kV STANDARDS: IEC 60092-353.5kV (if voltage to earth does not exceed 0.6/1kV CABLES 42 LKAM-FRHF DESIGN: Fire-resistant screened power and control cable 0.aluminium polyester tape. class 2 . manufacturer's name and meter marking printed on the sheath Tel.com . especially when lightweight cables are needed. cable type. voltage.9/1.stranded copper conductor IEC 60228.0.2kV) DC 0.helkamabica. Main characteristics Rated voltage AC 0. 5 19x2. bending radius fixed installation mm 2x1.5 17.5 19x1.5 12.0 115 140 165 200 250 400 450 515 580 740 810 140 175 215 270 625 700 820 1035 1140 20 16 16 13 12 10 10 9 9 8 8 26 21 21 17 13 12 11 10 10 60 60 65 75 80 105 110 120 125 145 150 65 70 75 80 125 130 140 165 170 G-type is with yellow/green earth conductor and marking on sheath is. for example.5 4x2.5 4x1.5 27x2.5 16x2.5 2x2.5 9.5 27.5 3x1.5 14x2.5 24x1.5 11.5 24x2.5 25.5 14x1.0 10.6/1kV CABLES LKAM-FRHF 0.0 23.5 27x1.5 18.5 13.0 12.5 24.5 5x2.5 12x1.5 19.5 7x1.5 20.5 11.43 Part number Normal G-type – 28744 28748 28752 – – – – – – – – 28746 28750 28754 – – – – – Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.6/1kV .5 10.5 3x2.5 5x1.5 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 28741 28743 28747 28751 28755 28763 28767 28771 28775 28779 28783 28742 28745 28749 28753 28769 28773 28777 28781 28785 Number of conductors & cross-section n x mm2 0.5 22.5 28.5 20.5 16x1. 3G1.0 13. .tinned stranded copper conductor on request 2. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. SHF2 .com . manufacturer's name and meter marking printed on the sheath Tel. Insulation . cable type. www. standards. fax +358 2 237 2428. SHF1 EC 60092-359 .stranded copper conductor IEC 60228. cable size. voltage. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number.separator tape 4. class 2 . Bedding .helkamabica. thermosetting polyolefine.250V CABLES 44 LKM-HF Unarmoured control and instrumentation cable 250V DESIGN: STANDARDS: IEC 60092-376. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. +358 2 410 8700. Sheath .standard colour grey.on request.XLPE plastic IEC 60092-351 5/2014 3. design 1. production month.polyolefine plastic. temperature. Conductor . 75 32x0.0 11.75 6.4 4.75 4x0.8 3.5 14x0.0 12.9 6.0 12.0 13.6 5.8 5.5 4x0.3 9.9 4.5 4.5 6.5 15.5 11.5 7.4 6.5 13.6 6.45 Part number Nominal outer diameter mm 2x0.5 10x0.8 4.75 20x0.9 8.5 12.6 6.5 16.5 10.5 16.75 24x0.75 10x0.3 7.4 5.0 7.0 6.75 27x0.5 3.7 4.75 37x0.1 4.3 5.2 5.0 18.75 14x0.5 20x0.75 16x0.5 8.75 12x0.0 7.5 11.0 15.9 5.5 8.75 5x0. bending radius fixed installation mm 25 25 30 30 30 40 45 45 45 50 55 60 60 60 65 25 30 30 30 35 45 45 50 50 55 60 65 65 65 70 5/2014 27821 27822 27823 27824 27825 27826 27827 27828 27829 27830 27831 27832 27833 27834 27835 26365 26366 26367 26368 26369 26370 26371 26372 26373 26374 26375 26376 26377 26378 26379 Number of conductors & cross-section n x mm2 250V CABLES LKM-HF 250V .75 3x0.7 7.6 4.1 4.5 7.5 3x0.8 8.0 Other sizes on request.3 11.5 37x0.5 7x0.5 14.1 3.5 14.75 19x0.0 8.0 16.5 24x0.75 7x0.0 10.5 19x0.2 4.5 2x0.5 32x0.5 16x0. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Approximate weight kg/km 40 50 60 70 85 125 140 160 175 200 220 250 275 310 350 50 60 75 85 110 160 180 200 235 265 285 335 365 415 470 Current Rating A at +45°C 8.5 5x0.3 Min.5 27x0.5 17.5 12x0.0 13.7 3. standards. SHF1 EC 60092-359 . fax +358 2 237 2428. coverage > 90% IEC 60092-350 .250V CABLES 46 LKSM-HF Armoured control and instrumentation cable 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376. class 2 . cable size.drain wire copper (in all sizes) . category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number. Armour . other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables.helkamabica. temperature.separator tape 4.copper wire braid. production month. cable type.tinned stranded copper conductor on request 2. Conductor .polyolefine plastic. Insulation . thermosetting polyolefine.standard colour grey.stranded copper conductor IEC 60228. www. Sheath . voltage. Bedding . SHF2 . +358 2 410 8700. design 1. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.tinned copper wire braid on request 5.on request.com .XLPE plastic IEC 60092-351 3. manufacturer's name and meter marking printed on the sheath Tel. 47 Part number 2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Crosssection of armour mm2 3,1 3,1 3,1 3,2 3,5 4,6 4,8 5,1 5,5 5,8 6,1 6,8 6,9 9,9 10,9 3,6 3,6 3,6 4,1 4,1 5,1 5,3 5,6 6,1 6,3 11,0 11,7 11,7 11,8 11,9 Nominal outer diameter mm 7,0 7,5 8,0 8,5 9,0 11,5 11,5 12,0 12,5 13,5 14,0 15,5 15,5 16,5 18,0 7,5 7,5 8,5 9,5 10,0 12,5 12,5 13,0 14,0 14,5 18,0 17,0 17,5 18,0 19,5 Approximate weight kg/km 80 85 95 110 125 180 195 215 235 265 285 325 345 420 470 90 100 115 140 165 220 245 270 300 330 455 450 485 545 605 Current Rating A at +45°C Min. bending radius fixed installation mm 8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 40 45 45 50 55 70 70 70 75 80 85 90 95 100 105 45 45 50 55 60 75 75 80 85 85 110 100 105 110 115 5/2014 27779 27780 27781 27782 27783 27784 27785 27786 27787 27788 27789 27790 27791 27792 27793 26402 26403 26404 26405 26407 26410 26412 26414 26416 26419 26420 26424 26427 26432 26437 Number of conductors & cross-section n x mm2 250V CABLES LKSM-HF 250V 250V CABLES 48 LKAM-HF Screened control and instrumentation cable 250V DESIGN: STANDARDS: IEC 60092-376, design 5/2014 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-351 3. Screen - drain wire of tinned copper - aluminium polyester tape, coverage 100% IEC 60092-350 4. Sheath - polyolefine plastic, SHF1 EC 60092-359 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships, especially when lightweight cables are needed. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com 49 Part number Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min. bending radius fixed installation mm 2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 10x0,5 12x0,5 14x0,5 16x0,5 19x0,5 20x0,5 24x0,5 27x0,5 32x0,5 37x0,5 2x0,75 3x0,75 4x0,75 5x0,75 7x0,75 10x0,75 12x0,75 14x0,75 16x0,75 19x0,75 20x0,75 24x0,75 27x0,75 32x0,75 37x0,75 6,0 6,5 7,0 7,5 8,0 10,5 11,0 11,5 12,0 12,5 13,5 14,5 15,0 15,5 16,5 6,5 7,0 7,5 8,0 9,0 11,5 12,0 12,5 13,0 13,5 17,0 16,0 16,5 17,0 18,5 45 55 65 75 90 130 145 165 180 205 225 260 280 325 365 55 65 80 95 120 165 190 215 240 270 345 340 370 430 485 8,7 7,6 6,9 6,4 5,8 5,1 4,8 4,6 4,4 4,1 4,1 3,8 3,7 3,5 3,3 11,3 9,8 8,9 8,3 7,4 6,6 6,2 5,9 5,6 5,3 5,2 4,9 4,7 4,5 4,3 25 25 30 30 30 40 45 45 45 50 55 60 60 60 65 25 30 30 30 35 45 45 50 50 55 70 65 65 70 75 Other sizes on request. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 26440 26441 26442 26443 26444 26445 26446 26447 26448 26449 26450 26451 26452 26453 26454 26382 26383 26384 26385 26386 26387 26388 26389 26390 26391 26392 26393 26394 26395 26396 Number of conductors & cross-section n x mm2 250V CABLES LKAM-HF 250V 250V CABLES 50 RFE-HF Armoured instrumentation and communication cable 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376, design 1. Conductor - stranded copper conductor IEC 60228, class 2 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic IEC 60092-351 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Bedding - filler tape 5. Armour - drain wire copper (in all sizes) - copper wire braid, coverage > 94% IEC 60092-350 - tinned copper wire braid on request 6. Sheath - polyolefine plastic, SHF1 EC 60092-359 - on request, thermosetting polyolefine, SHF2 - standard colour grey, other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) Halogen-free Smoke emission + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A IEC 60754 series IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Electrical data: Loop resistance of pair, max. / +20°C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20°C 0,5mm2 0,75mm2 80 52 55 50 0,6 0,6 ≥1500 ≥1500 1,5mm2 24,4 60 0,7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath Tel. +358 2 410 8700, fax +358 2 237 2428, www.helkamabica.com 0 10.75 10x2x0.5 11. 3.5 1x2x0. 2.5 Quad 2x2x0.0 29.5 24x2x1.5 8x2x0.75 8x2x0.5 17.5 12x2x1.blue. 4. Cores numbered 1.75 32x2x0.5 21.5 21.0 20.5 37x2x0.5 26.5 25.5 7x2x0.75 2x2x0.0 21.5 18.5 32x2x1.5 2x2x0.5 9.5 24.5 14x2x1.0 17.5 12x2x0.0 23.5 24x2x0.5 19x2x0.5 27.75 4x2x0.75 19x2x0.5 85 105 130 175 245 270 355 390 440 485 545 670 930 95 125 155 215 330 375 440 490 565 620 715 860 1100 135 190 235 375 545 625 760 855 960 1230 1530 1950 45 50 60 70 85 85 100 105 110 120 125 140 170 45 55 65 75 90 95 110 115 125 130 140 155 175 60 65 85 100 120 130 145 155 165 185 210 235 1x2x0.0 39.5 9.5 16.5 11.. 5.5 28.0 7. (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 20362 20364 20363 20366 20368 20369 20370 20371 20372 20373 20374 20376 20378 20382 20384 20383 20386 20388 20389 20390 20391 20392 20393 20394 20396 20398 20490 20491 20492 20493 20494 20495 20496 20497 20498 20499 20500 20501 Number of conductors & cross-section n x mm2 250V CABLES RFE-HF 250V .0 14.5 19.75 14x2x0.5 8x2x1..5 19.5 10x2x1.0 35.5 14.75 16x2x0.5 15.5 23.5 4x2x1.0 14.75 12x2x0.5 7x2x1.5 Quad 2x2x1.0 17.0 11.75 7x2x0.0 12.5 10x2x0.5 14x2x0.0 18.5 16x2x0.5 2x2x1.0 8.75 Quad 2x2x0.75 1x2x1.5 4x2x0.75 24x2x0.51 Part number Nominal outer diameter mm Approximate weight kg/km Min.5 Core identification Each pair white .5 19x2x1.0 20..0 31. bending radius fixed installation mm 7. copper wire braid. / +20°C Pair capacitance.stranded copper conductor IEC 60228. fax +358 2 237 2428.two insulated cores twisted together to form a pair .tinned stranded copper conductor on request 2. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. cable type. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) Halogen-free Smoke emission + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. Insulation resistance / +20°C 0. class 2 .6 0. coverage > 94% IEC 60092-350 . design 1. www. Insulation .250V CABLES 52 RFE-HF (i) 5/2014 DESIGN: Armoured and pair screened instrumentation and communication cable 250V STANDARDS: IEC 60092-376.6 ≥1500 ≥1500 1. Twisted pair & pair screen .on request. cable size. thermosetting polyolefine.5mm2 0. / 800Hz Loop inductance. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. temperature. Sheath . SHF1 EC 60092-359 .tinned copper wire braid on request 6. Bedding .helkamabica.7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number. category A IEC 60754 series IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Electrical data: Loop resistance of pair. manufacturer's name and meter marking printed on the sheath Tel.standard colour grey.polyolefine plastic.75mm2 80 52 55 70 0.4 90 0.com . nom. Armour .5mm2 24.filler tape 5. SHF2 . +358 2 410 8700. voltage. nom. Conductor .XLPE plastic IEC 60092-351 3.drain wire copper (in all sizes) . production month. max.plastic coated aluminium tape and a tinned copper drain wire 4. standards. 5 17.0 12.75 12x2x0.5 4x2x1.5 37x2x0.5 1x2x0.5 7x2x0.0 11.5 29. 5.5 10x2x0.0 24.5 13.0 20..0 19.5 3x2x0.5 24x2x0.5 2x2x0... Cores numbered 1.0 10.75 4x2x0.0 22..75 10x2x0.75 1x2x1..0 15.53 Part number Nominal outer diameter mm Approximate weight kg/km Min. The pairs are also covered by a numbered tape (1.75 8x2x0.75 1x4x0.0 27.0 32.5 1x4x0.0 25. 5.5 9.75 14x2x0.5 32x2x0.0 26.5 17..0 14. 3.5 12x2x1.5 14x2x0.5 18.0 11.5 8x2x1.5 27.blue.5 8x2x0.75 7x2x0.5 12x2x0.0 25.5 19x2x0.5 26.0 20.0 21.5 4x2x0.5 8.) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 22338 22340 22342 22344 22346 22348 22350 22352 22354 22356 22358 22360 22362 22364 22366 22368 22370 22372 22006 22008 22010 22012 22014 22016 22018 22020 22022 22024 22026 22050 22052 22054 22056 22058 22060 22062 22064 22066 22068 Number of conductors & cross-section n x mm2 250V CABLES RFE-HF(i) 250V .0 10.5 7x2x1.5 7.5 16x2x0.0 90 105 120 155 185 215 320 385 470 530 590 655 770 935 1030 1120 1190 1340 95 140 170 240 375 420 520 585 650 835 1035 145 200 255 415 610 700 855 965 1105 1440 45 45 50 65 65 70 85 90 105 110 115 120 130 145 150 160 165 175 45 55 70 75 95 100 115 120 125 145 160 60 65 85 100 120 130 150 155 165 190 Core identification Each pair white . bending radius fixed installation mm 1x2x0.0 7. 4. 2.5 27x2x0.0 22. 3.0 14.0 28.0 15.5 1x4x1.5 7.75 2x2x0.5 1x3x0.5 11.5 14x2x1.0 24.75 19x2x0.0 20.5 2x2x1.5 10x2x1.5 19. 2.5 19x2x1.5 16.5 30x2x0.75 24x2x0. 4. temperature. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.75mm2 80 52 55 50 0. manufacturer's name and meter marking printed on the sheath Tel. www. Sheath . nom. Screen . Twisted pair . SHF2 .5mm2 24.helkamabica.250V CABLES 54 RFA-HF Screened instrumentation and communication cable 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376. max.drain wire tinned copper . Insulation resistance / +20°C 0. / +20°C Pair capacitance.7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number. cable type. class 2 . Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. especially when lightweight cables are needed. category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series Electrical data Loop resistance of pair. production month.two insulated cores twisted together to form a pair See next page for Quad 4. cable size. / 800Hz Loop inductance. voltage.polyolefine plastic. standards. thermosetting polyolefine. Conductor .tinned stranded copper conductor on request 2. +358 2 410 8700.6 0. fax +358 2 237 2428.5mm2 0. design 1. Insulation .on request.com .aluminium polyester tape IEC 60092-350 coverage 100% 5. SHF1 EC 60092-359 . other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships.XLPE plastic IEC 60092-351 3.stranded copper conductor IEC 60228.4 60 0. nom.standard colour grey.6 ≥1500 ≥1500 1. 5 22.75 16x2x0.75 24x2x0.0 13.5 19x2x0.5 14.5 15.0 9.5 19x2x1.75 10x2x0.5 8.5 8x2x1.5 8x2x0.0 11.5 10x2x1..0 10.5 13. 5.5 2x2x1.5 20.5 12x2x1.5 Core identification Each pair white .5 16x2x0.0 25. bending radius fixed installation mm 45 65 75 120 175 200 245 280 315 350 410 515 665 745 55 80 100 150 225 260 320 365 415 480 555 680 85 125 140 165 210 260 410 465 590 675 780 875 1025 1285 35 40 55 65 75 80 95 95 105 110 120 135 150 160 40 45 60 70 85 90 100 105 115 125 130 145 50 55 60 80 85 90 110 120 140 145 155 165 180 200 5/2014 20910 20912 20914 20916 20918 20920 20922 20924 20926 20928 20930 20932 20934 20936 20970 20972 20974 20976 20978 20980 20982 20984 20986 20988 20990 20992 21356 21357 21358 21359 21360 21361 21362 21363 21364 21365 21366 21367 21368 21369 Number of conductors & cross-section n x mm2 250V CABLES RFA-HF 250V .5 4x2x0.75 8x2x0.0 7.5 14x2x1.75 19x2x0.0 20.5 12.5 10. 3.0 14.75 12x2x0.5 7x2x0.5 Quad 2x2x1.75 14x2x0. 2.5 27.5 30.5 24x2x0.75 4x2x0.0 22.5 14x2x0.55 Part number Nominal outer diameter mm 1x2x0.75 7x2x0.5 37x2x0.blue. 4.5 7.5 2x2x0.75 Quad 2x2x0.0 26..0 19.0 33..0 20.0 10.5 16x2x1. (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 6.75 1x2x1.5 9.5 Quad 2x2x0.5 1x2x0.5 12x2x0.5 24x2x1.5 10x2x0.0 17.75 2x2x0.0 27.5 16.0 24.5 1x3x1.5 18. Cores numbered 1.5 4x2x1.5 Approximate weight kg/km Min.5 7x2x1.0 17.5 3x2x1.5 18.0 24.0 15.0 15.0 6.5 32x2x0.0 23.0 18. 5mm2 0.helkamabica.stranded copper conductor IEC 60228. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Halogen-free Smoke emission 150/250V (300V) + 90 °C IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables.two insulated cores twisted together to form a pair . www. Twisted pair & pair screen . Sheath .drain wire tinned copper IEC 60092-350 .5mm2 24. Collective screen .separator tape 5. class 2 . SHF2 .aluminium polyester tape.on request. Conductor .XLPE plastic IEC 60092-351 3. Insulation resistance / +20°C 0.plastic coated aluminium tape and a tinned copper drain wire 4. voltage. fax +358 2 237 2428.standard colour grey. design 1. other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. SHF1 EC 60092-359 .7 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number. thermosetting polyolefine. temperature. manufacturer's name and meter marking printed on the sheath Tel.250V CABLES 56 RFA-HF (i) 5/2014 DESIGN: Collectively and pair screened instrumentation and communication cable 250V STANDARDS: IEC 60092-376. especially when lightweight cables are needed.4 90 0. cable size. Insulation .com . category A IEC 60754 series IEC 61034 series Electrical data Loop resistance of pair. coverage 100% 6. max. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. production month. cable type.6 ≥1500 ≥1500 1. Loop inductance. / +20°C Pair capacitance. nom. Bedding . standards.tinned stranded copper conductor on request 2.75mm2 80 52 55 70 0. nom.polyolefine plastic. +358 2 410 8700.6 0. 5.0 22.5 17.5 19x2x1. 4.5 14x2x1.0 15. Cores numbered 1.0 16.5 14.5 10.57 Part number Nominal outer diameter mm Approximate weight kg/km Min.75 4x2x0.0 14.75 7x2x0.5 19.0 13.0 13.5 19x2x0.0 17.5 24x2x1.5 19.5 23.5 14x2x0.5 1x3x1.5 15.5 7x2x1. 5.0 95 145 220 245 305 350 395 450 520 655 115 180 275 310 380 440 520 580 680 840 95 120 185 240 305 480 560 690 800 910 1035 1200 1520 55 65 80 85 95 100 105 115 120 135 60 70 85 90 105 110 120 125 135 150 50 55 80 85 95 115 125 140 150 160 170 180 205 Other sizes on request.5 8x2x0.75 12x2x0..) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 20940 20942 20944 20946 20948 20950 20952 20954 20956 20958 21059 21061 21063 21065 21067 21069 21071 21073 21075 21077 21375 21376 21378 21379 21380 21381 21382 21383 21384 21385 21386 21387 21388 Number of conductors & cross-section n x mm2 250V CABLES RFA-HF(i) 250V .75 24x2x0. 2.0 16.75 10x2x0.5 11.0 14.5 10x2x1..75 8x2x0.0 19.5 12x2x0. The pairs are covered by a numbered tape (1.blue.5 24x2x0.5 4x2x1.5 2x2x0.0 34.5 2x2x1.5 12x2x1.5 8x2x1.0 20.5 26. Core identification Each pair white .0 8.0 30.75 14x2x0.5 7x2x0..5 9.5 10x2x0..5 24.5 28.75 19x2x0.5 18.75 16x2x0.0 20.. 4.5 4x2x0.5 16x2x1.5 25. 3. bending radius fixed installation mm 2x2x0.5 21.5 3x2x1.5 16x2x0.0 12. 2..75 1x2x1.5 9. 3.0 22. temperature.separator tape Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 4.on request thermosetting polyolefine. SHF2. fax +358 2 237 2428.XLPE plastic IEC 60092-351 5/2014 3. +358 2 410 8700. SHF1. Sheath . standards. Insulation . cable size. www.com . standard colour orange  IEC 60092-359 .250V CABLES 58 LKM-FRHF DESIGN: Fire-resistant unarmoured control and instrumentation cable 250V STANDARDS: IEC 60092-376. Conductor .polyolefine plastic. manufacturer's name and meter marking printed on the sheath Tel. standard colour black . If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.other colours on request Application: For fixed installation in most areas and on open deck in ships.stranded copper conductor IEC 60228.Mica tape . design 1.tinned stranded copper conductor on request 2. production month. category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number. Bedding . voltage. cable type. class 2 .helkamabica. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. 0 130.0 410.2 5.0 11.5 22.0 615.9 5.0 110.0 520.9 4.0 695.0 10.0 15.75 5x0.5 17.0 160.5 9.75 14x0.75 24x0.3 7.0 330.6 5.0 11.0 11.7 4.5 16.59 Part number Nominal outer diameter mm Approximate weight kg/km Current Rating A at +45°C Min.75 4x0.75 37x0.5 15. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 22406 22407 22408 22409 22410 22411 22412 22413 22414 22415 22416 22417 22418 22419 22420 Number of conductors & cross-section n x mm2 250V CABLES LKM-FRHF 250V .9 8.75 27x0.0 375.75 3x0.0 21.8 8.75 7x0.75 32x0.3 35 35 40 45 45 60 60 65 70 75 75 85 85 90 100 Other size on request.0 255.3 9.75 10x0.75 12x0.0 23.0 25.75 16x0.0 295.5 18.6 6.3 5.0 80.2 4.75 20x0.4 6.0 475.75 19x0. bending radius fixed installation mm 2x0.5 4.0 225.75 8.0 19.0 65. www. cable size. class 2 . voltage. Sheath .polyolefine plastic.tinned copper wire braid on request IEC 60092-350 Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 5. Bedding .tinned stranded copper conductor on request 2. SHF1. SHF2.250V CABLES 60 LKSM-FRHF DESIGN: Fire-resistant armoured control and instrumentation cable 250V STANDARDS: IEC 60092-376.helkamabica. Insulation . cable type. category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number. +358 2 410 8700. Armour .XLPE plastic EC 60092-351 5/2014 3.copper wire braid.separator tape 4. standard colour orange  IEC 60092-359 . standard colour black .drain wire copper (in all sizes) . temperature.other colours on request Application: For fixed installation in most areas and on open deck in ships.com . design 1.on request thermosetting polyolefine. Conductor .stranded copper conductor IEC 60228.Mica tape . If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. fax +358 2 237 2428. production month. coverage > 90% . manufacturer's name and meter marking printed on the sheath Tel. standards. 75 3x0. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Crosssection of armour mm2 3.7 Nominal outer diameter mm 9.3 7.6 6.3 14.0 11.5 20.5 23.75 14x0.3 16.0 Approximate weight kg/km 105 125 160 185 220 300 330 370 445 495 545 615 665 740 860 Current Rating A at +45°C Min. bending radius fixed installation mm 11.75 27x0.1 7.0 23.0 16.5 22.7 4.3 7.8 11.6 3.75 19x0.2 4.75 Other size on request.5 19.9 4.3 5.75 16x0.5 16.5 26.0 17.3 55 60 65 70 75 95 95 100 110 115 125 135 140 140 155 5/2014 22436 22437 22438 22439 22440 22441 22442 22443 22444 22445 22446 22447 22448 22449 22450 Number of conductors & cross-section n x mm2 250V CABLES LKSM-FRHF 250V .4 7.75 37x0.9 14.75 32x0.5 11.3 9.2 5.4 6.3 11.4 4.9 4.75 5x0.0 18.75 10x0.9 8.9 5.9 12.75 4x0.0 9.75 7x0.61 Part number 2x0.6 5.75 12x0.75 24x0.8 8.9 5.75 20x0.6 15.5 4.5 12. SHF2.other colours on request Application: For fixed installation in most areas and on open deck in ships. class 2 .helkamabica. standard colour orange  IEC 60092-359 . Insulation . Conductor . www. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. +358 2 410 8700. manufacturer's name and meter marking printed on the sheath Tel.XLPE plastic IEC 60092-351 3.on request thermosetting polyolefine.tinned stranded copper conductor on request 5/2014 2. cable type. category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Core identification: black numbers on white base Identification: Lot number. cable size.polyolefine plastic. SHF1.com . production month. Sheath .drain wire of tinned copper . Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. temperature. design 1. Screen . coverage 100% IEC 60092-350 Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 4. standard colour black .250V CABLES 62 LKAM-FRHF DESIGN: Fire-resistant screened control and instrumentation cable 250V STANDARDS: IEC 60092-376. voltage.stranded copper conductor IEC 60228. fax +358 2 237 2428.aluminium polyester tape. especially when lightweight cables are needed. standards.Mica tape . 75 32x0.2 5.0 23.75 10x0. Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Nominal outer diameter mm 8.75 12x0.5 16.3 5.5 18.7 4.75 20x0.5 22.75 Other size on request.6 5.5 9.75 19x0.3 7.75 24x0. bending radius fixed installation mm 11.0 19.2 4.3 9.3 50 55 60 65 70 90 95 100 105 110 115 130 130 140 150 5/2014 22466 22467 22468 22469 22470 22471 22472 22473 22474 22475 22476 22477 22478 22479 22480 Number of conductors & cross-section n x mm2 250V CABLES LKAM-FRHF 250V .75 16x0.0 11.0 11.4 6.5 17.75 14x0.0 10.9 5.63 Part number 2x0.0 15.75 37x0.0 25.75 27x0.9 8.75 3x0.5 15.5 4.8 8.75 7x0.75 5x0.75 4x0.6 6.9 4.5 21.0 Approximate weight kg/km 70 85 115 135 165 230 260 300 340 380 415 480 525 620 700 Current Rating A at +45°C Min. 7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number. www. standard colour orange  IEC 60092-359 . manufacturer's name and meter marking printed on the sheath Tel. Insulation resistance / +20°C 0.tinned copper wire braid on request 6. / +20°C Pair capacitance. production month. class 2 . temperature.com . cable type. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.stranded copper conductor IEC 60228. max.6 0.75mm2 1. standard colour black .polyolefine plastic.filler tape 5. Insulation .copper wire braid. cable size.two insulated cores twisted together to form a pair See next page for Quad 4. fax +358 2 237 2428. Bedding . Conductor . nom. voltage. nom.other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships.250V CABLES 64 RFE-FRHF Fire-resistant armoured instrumentation and communication cable 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376. SHF2. Armour .on request thermosetting polyolefine. design 1. / 800Hz Loop inductance.tinned stranded copper conductor on request 2. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature + 90 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables.helkamabica. Sheath . SHF1.5mm2 52 24.Mica tape . category A Fire-resistant Halogen-free Smoke emission IEC 60331-1 or IEC 60331-2 IEC 60754 series IEC 61034 series Oil resistance (only SHF2) IEC 60811-2-1 conditions according to 60092-359/SHF2 Electrical data Loop resistance of pair.drain wire (in all sizes) . +358 2 410 8700. coverage > 94% IEC 60092-350 .XLPE plastic IEC 60092-351 3. standards.4 45 55 0. Twisted pair . 0 14.0 31.5 20.0 24. bending radius fixed installation mm 115 170 210 330 470 515 640 710 810 1025 1260 1605 155 220 315 430 655 725 880 1010 1135 1290 1475 55 65 85 100 120 125 145 150 165 185 205 235 65 70 95 110 135 145 165 175 185 195 210 Core identification Each pair white . 2.0 16.5 Quad 2x2x1. (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 20520 20522 20524 20526 20528 20530 20532 20534 20536 20538 20540 20542 20575 20577 20579 20581 20583 20585 20587 20589 20591 20593 20595 Number of conductors & cross-section n x mm2 250V CABLES RFE-FRHF 250V .5 29.5 19x2x1..5 12.75 10x2x0.5 2x2x1.blue.4 10. Cores numbered 1.5 33.5 12x2x1.2 Approximate weight kg/km Min.5 7x2x1.0 34.5 8x2x1. 5.5 4x2x1.0 27.5 9.0 30.0 35.75 32x2x0.5 25.5 16x2x1.5 10x2x1.5 27.75 12x2x0. 4.0 18.75 14x2x0.5 39.0 21.65 Part number Nominal outer diameter mm 1x2x0. 3.5 14x2x1..75 4x2x0.75 Quad 2x2x0.75 8x2x0.75 24x2x0.75 1x2x1..75 2x2x0.5 11.5 24.75 7x2x0.75 19x2x0.5 22.0 16. SHF1.two insulated cores twisted together to form a pair Halogen.stranded copper conductor IEC 60228. manufacturer's name and meter marking printed on the sheath Tel. cable size.com .drain wire copper (only SHF2) . standard colour black .5mm2 52 24. / 800Hz Loop inductance. category A IEC 60331-1 or IEC 60331-2 IEC 60754 series IEC 61034 series Electrical data Loop resistance of pair. +358 2 410 8700.filler tape emission 5. fax +358 2 237 2428.tinned copper wire braid on request 6.polyolefine plastic. standards. cable type.tinned stranded copper conductor on request 2. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Main characteristics Rated voltage Maximum conductor temperature Flame-retardant Fire-resistant Halogen-free Smoke emission 150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22 -test for single insulated wire and cable -test for bunched wires and cables.7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number. temperature. Conductor .XLPE plastic IEC 60092-351 Fire3. Armour Oil resistant . design 1.copper wire braid. coverage > 94% IEC 60092-350 . SHF2.on request thermosetting polyolefine.250V CABLES 66 RFE-FRHF (i) 5/2014 DESIGN: Fire-resistant armoured and pair screened instrumentation and communication cable 250V STANDARDS: IEC 60092-376. nom.other colours on request Application: For fixed installation in most areas and on open deck in ships. Sheath .75mm2 1. max. / +20°C Pair capacitance.6 0. www.plastic coated aluminium tape and a tinned copper drain wire free 4.helkamabica. nom. Bedding Low smoke . Insulation Flame. voltage.4 55 75 0. production month. class 2 . standard colour orange  IEC 60092-359 . Twisted pair & pair screen resistant .Mica tape retardant . Insulation resistance / +20°C 0. 0 41.0 27.5 32.75 4x2x0.0 20.75 1X4X0.5 10x2x1.0 14.75 12x2x0.0 25. The pairs are also covered by a numbered tape (1. Cores numbered 1.75 10x2x0..0 24.5 14x2x1.5 8x2x1.5 1X4X1.blue..0 26.5 11.0 10.5 4x2x1. 2.5 19. 5.0 16.75 7x2x0.5 7x2x1.0 35.75 14x2x0. 5. 4.75 8x2x0..5 19x2x1. 3..0 29.0 23.5 36.0 125 175 225 355 510 585 710 800 910 1175 1425 1945 165 225 320 475 720 805 985 1145 1290 1450 1665 55 65 85 100 120 130 150 155 165 190 210 245 65 75 100 115 135 145 165 175 190 200 215 Core identification Each pair white .75 19x2x0. bending radius fixed installation mm 1x2x0.5 9. 3..0 22.5 12x2x1.5 31.5 16x2x1.75 24x2x0.5 28.5 33.67 Part number Nominal outer diameter mm Approximate weight kg/km Min.75 32x2x0.5 17. 4.) Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 20546 20548 20550 20552 20554 20556 20558 20560 20562 20564 20566 20568 20603 20604 20605 20607 20609 20611 20613 20615 20617 20619 20621 Number of conductors & cross-section n x mm2 250V CABLES RFE-FRHF(i) 250V .75 2x2x0.5 12.75 1x2x1..5 2x2x1. 2. drain wire tinned copper . production month. / +20°C Pair capacitance. Conductor . SHF1.XLPE plastic IEC 60092-351 3.com . category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series For details see general information section Electrical data Loop resistance of pair. cable type. SHF2.two insulated cores twisted together to form a pair See next page for Quad 4. Insulation resistance / +20°C 0. Sheath .stranded copper conductor IEC 60228. manufacturer's name and meter marking printed on the sheath Tel. standards.other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. coverage 100% IEC 60092-350 5.polyolefine plastic. class 2 .5mm2 52 24. nom. design 1. +358 2 410 8700. Screen . nom. www. cable size.tinned stranded copper conductor on request 2. voltage.on request thermosetting polyolefine. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number. Twisted pair . Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22 -test for single insulated wire and cable -test for bunched wires and cables.Mica tape . fax +358 2 237 2428. max. Insulation . temperature.75mm2 1.6 0.aluminium polyester tape.helkamabica. standard colour orange  IEC 60092-359 . standard colour black . / 800Hz Loop inductance.250V CABLES 68 RFA-FRHF Fire-resistant screened instrumentation and communication cable 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376.4 45 55 0. 5 27.69 Part number 20635 20637 20639 20641 20643 20645 20647 20649 20651 20653 20655 20657 21521 Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Min.0 15.5 29. (Quad)cable is built up as a star quad with the following identification 1 core white 2 core blue 3 core white 4 core blue Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 Core identification 250V CABLES RFA-FRHF 250V . 3.75 2x2x0.0 23.75 16x2x0.0 75 120 135 215 330 380 480 545 620 700 805 1030 100 50 60 80 90 110 120 140 145 155 165 175 200 55 1x2x0..5 18.75 7x2x0.0 24.5 10. Cores numbered 1..75 24x2x0.0 13. 2.5 9.75 4x2x0. bending radius fixed installation mm 8.5 Each pair white .. 4.75 12x2x0.75 14x2x0.blue. 5.5 33.0 25.75 10x2x0.75 8x2x0.5 20.75 Quad 2x2x0.75 1x2x1.75 19x2x0. on request thermosetting polyolefine. manufacturer's name and meter marking printed on the sheath Tel.polyolefine plastic. Insulation .aluminium polyester tape coverage 100 % IEC 60092-350 6.XLPE plastic IEC 60092-351 3. max. cable type.tinned stranded copper conductor on request 2. voltage. standard colour black . standard colour orange  IEC 60092-359 . Main characteristics Rated voltage Maximum conductor temperature Flame-retardant 150/250V (300V) + 90 °C IEC 60332-1-2 IEC 60332-3-22 -test for single insulated wire and cable -test for bunched wires and cables. design 1.other colours on request Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) Application: For fixed installation in most areas and on open deck in ships. Bedding . category A Fire-resistant IEC 60331-1 or IEC 60331-2 Halogen-free IEC 60754 series Smoke emission IEC 61034 series For details see general information section Electrical data Loop resistance of pair.5mm2 52 24. SHF2.4 55 75 0. / +20°C Pair capacitance.Mica tape .com . / 800Hz Loop inductance. Sheath .separator tape 5. standards.plastic coated aluminium tape and a tinned copper drain wire 4. cable size.helkamabica. +358 2 410 8700. Insulation resistance / +20°C 0. nom.7 ≥1500 ≥1500 Unit ohm/km nF/km mH/km Mohm/km Minimum recommended installation temperature -15 °C Lowest operation temperature -40 °C Identification: Lot number.75mm2 1.two insulated cores twisted together to form a pair . temperature.drain wire tinned copper . fax +358 2 237 2428. class 2 .stranded copper conductor IEC 60228.6 0. Collective screen .250V CABLES 70 RFA-FRHF (i) Fire-resistant collectively and pair screened instrumentation and communication cable 250V 5/2014 DESIGN: STANDARDS: IEC 60092-376. www. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. production month. nom. SHF1. Twisted pair & pair screen . Conductor . 5 15. 3. 2.5 4x2x1.75 24x2x0.75 8x2x0.75 10x2x0. The pairs are also covered by a numbered tape (1.0 30.75 2x2x1. 4..75 12x2x0.. 5.75 4x2x0. 2. 5...71 Part number 20667 20669 20671 20673 20675 20677 20679 20681 20683 20685 21553 21555 Number of conductors & cross-section n x mm2 Nominal outer diameter mm Approximate weight kg/km Min.5 26.5 13. bending radius fixed installation mm 2x2x0.blue.75 7x2x0.75 14x2x0.0 34.0 17.0 15. Cores numbered 1.) ..5 155 245 380 430 545 625 725 810 945 1205 215 350 80 95 110 120 140 145 155 165 180 205 90 105 250V CABLES RFA-FRHF(i) 250V Core identification Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx 5/2014 Each pair white .75 16x2x0.5 24.0 28. 3.75 19x2x0.5 20.0 23..5 18. 4. 48 fibres Cable characteristics: Maximum pulling force Crush strength / 100 mm (plate) Crush strength / 25 mm (mandrel) Impact strength Sheath marking Minimum installation temperature Operating temperature range Longitudinal water tightness Flame-retardant Halogen-free Smoke emission 500 N EN 187000 method 501 4000 N EN 187000 method 504 650 N EN 187000 method 504 25 J EN 187000 method 505 Cable type. UV-protected and halogen free sheath . manufacturing number and time. PP-slotted core. +358 2 410 8700. Central element glass fibre. 6..0 mm 3.+70 °C EN 187000 method 605B . Optical fibres. manufacturer's name. Rip cord Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant (only SHF2) 5/2014 6. Slotted core cables have blue and red marker threads for the first and last slot respectively.Fibres: 250 μm SM or MM fibres . IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables. fax +358 2 237 2428. www. length marking in meter -15 °C -45.helkamabica.com . category A IEC 60754 series IEC 61034 series For details see general information section Tel.OPTICAL FIBRE CABLE 72 FXMSU Optical fibre indoor/outdoor cable Cable construction: 1. 250 μm 4. 1..non-metallic ..5 mm 2.4 . Swellable tape 5.networks in marine applications . 4 75 140 100 5/2014 10001 10022 10024 10028 14384 14386 14388 14398 14404 14406 14408 14410 14412 14416 14420 14422 14424 14426 14428 14449 14450 14451 14454 14455 Cable and number of fibres OPTICAL FIBRE CABLE FXMSU . mm 6 Nominal Approximate Minimum bending radius outer weight.73 Part number FXMSU 1X4SML (L) FXMSU 1X6SML (L) FXMSU 2X6SML (L) FXMSU 4X6SML (L) FXMSU 1X4OM3L (L) FXMSU 2X4OM3L (L) FXMSU 3X4OM3L (L) FXMSU 4X6OM3L (L) FXMSU 1X4GKL (L) FXMSU 1X6GKL (L) FXMSU 2X4GKL (L) FXMSU 3X4GKL (L) FXMSU 4X4GKL (L) FXMSU 4X6GKL (L) FXMSU1X4SML+1X4GKL (L) FXMSU1X4SML+2X4GKL (L) FXMSU2X4SML+2X4GKL (L) FXMSU1X6SML+3X4GKL (L) FXMSU2X6SML+3X4GKL (L) FXMSU1X4SML+1X4OM3 (L) FXMSU1X4SML+2X4OM3L (L) FXMSU2X4SML+2X4OM3L (L) FXMSU1X6SML+3X4OM3L (L) FXMSU2X6SML+3X4OM3L (L) Other fiber combinations on request Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Diameter of slotted core. mm mm mm 9. during final diameter. installation. kg/km installation. mm mm mm 10.Fibres: 2–8 SM or MM fibres. installation.Connectors can be mounted directly to the fibres Cable characteristics: Maximum pulling force Crush strength / 100 mm (plate) Crush strength / 25 mm (mandrel) Impact strength. kg/km installation. www.helkamabica. fax +358 2 237 2428.5 mm . Installation cable unit FMS 1 (2 mm) 4. manufacturing number and time. manufacturer's name. PP-slotted core 3.For tray installation .7 102 160 110 13. length marking in meter 195 mm during installation. 130 mm in final bending 13.OPTICAL FIBRE CABLE 74 FXMMS Optical fibre installation cable Cable construction: Flameretardant Fireresistant Halogenfree Low smoke emission Oil resistant 1.. Fire barrier tape 5. Halogen free sheath 1.+70 °C Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables category A Halogen-free IEC 60754 series Smoke emission IEC 61034 series For details see general information section Cable and number of fibres FXMMS 2-4 Diameter of slotted core. mm 7. FRP central element 2 mm 2. +358 2 410 8700..1 mm 142 kg/km -15 °C -45. during final diameter.7 Nominal Approximate Minimum bending radius outer weight.1 142 195 130 Tel. 900 μm .com . R = 300 mm Sheath marking Minimum bending radius Nominal cable diameter Cable weight Minimum installation temperature Operating temperature range 1500 N EN 187000 method 501 4000 N EN 187000 method 504 750 N EN 187000 method 504 30 J EN 187000 method 505 Cable type.5 FXMMS 6-8 9. Rip cord (only SHF2) 5/2014 6. 1 142 195 130 5/2014 Part number for oil resistant SHF2 cable: 4 + code from above table © 4xxxxx Diameter of slotted core.5 7.5 7. mm mm mm 10.1 142 195 130 13.7 102 160 110 10.7 102 160 110 13.7 102 160 110 10.5 9.1 142 195 130 13.75 Part number 10810 10812 10814 10816 13747 13748 13749 13750 13872 13874 13876 13878 Cable and number of fibres FXMMS 2SMT (2MM) FXMMS 4SMT (2MM) FXMMS 6SMT (2MM) FXMMS 8SMT (2MM) FXMMS 2GKT (2MM) FXMMS 4GKT (2MM) FXMMS 6GKT (2MM) FXMMS 8GKT (2MM) FXMMS 2OM3T (2MM) FXMMS 4OM3T (2MM) FXMMS 6OM3T (2MM) FXMMS 8OM3T (2MM) Nominal Approximate Minimum bending radius outer weight.7 102 160 110 13.7 7.7 9. installation.7 OPTICAL FIBRE CABLE FXMMS .7 102 160 110 10.7 7.1 142 195 130 13.5 9.1 142 195 130 10.7 9.5 9.5 7. mm 7.1 142 195 130 10. during final diameter.7 9. kg/km installation.7 102 160 110 13. 25 dB/km 1300. www. NA Fibre identification 850 nm 1300 nm 850 nm 1300 nm 850 nm Tel.200 +/.1324 nm ≤ 0.5 μm 125 +/.0.helkamabica..0.D) 1550 nm 50/125 μm 9.OPTICAL FIBRE CABLE 76 Cabled optical fibres characteristics Fibre coating: L = 250 μm ± 10 μm T = 900 μm ± 50 μm Single mode fibre 10/125 μm Fibre type SML 250μm±10μm SMT 900μm±50μm 5/2014 Mode field diameter (MFD) Mode field eccentricity -Installation cables Cladding diameter . +358 2 410 8700.40 dB/km ≤ 0.com .015 6 colour system according to SFS 5648 Bandwidth Numerical aperture..652.Installation cables Polarization mode dispersion Proof test Fibre identification Multi mode fibre SM / OS2 (ITU-T G.7 dB/km ≤ 0.8 dB/km ≥ 1500 MHz x km (LED) ≥ 500 MHz x km (LED) ≥ 2000 MHz x km (Laser) 0.1 μm ≤2% ≤ 0.093 ps/nm2/km ≤ 18 ps/nm/km ≤ 1260 nm 1180.1250 nm ≤ 0.Installation cables Cladding ellipticity Fibre attenuation 1310 nm 1310 nm 1550 nm Zero dispersion range Dispersion coefficient .Dispersion at Cut-off wavelength ..2 μm 125 +/. fax +358 2 237 2428.0 μm ≤ 0.3 μm ≤6% ≤ 3 μm 125 +/.5 ps/√km 1 % / 1 sec 6 colour system according to SFS 5648 OM3 Fibre type OM3L 250μm±10μm OM3T 900μm±50μm Core diameter Core ellipticity Core eccentricity Cladding diameter Cladding ellipticity Fibre attenuation 50 +/.3 +/.5 μm ≤ 1..2 μm ≤2% ≤ 2. 5/125 μm GK / OM1 GKL 250μm±10μm GKT 900μm±50μm Core diameter Core ellipticity Core eccentricity Cladding diameter Cladding ellipticity Fibre attenuation 62.5 dB/km ≤ 1.015 6 colour system according to SFS 5648 Bandwidth Numerical aperture.2 μm ≤2% ≤ 3.0 dB/km ≥ 200 MHz x km ≥ 500 MHz x km 0.0.275 +/.77 62.3 μm ≤6% ≤ 3 μm 125 +/. NA Fibre identification 850 nm 1300 nm 850 nm 1300 nm 5/2014 Fibre type OPTICAL FIBRE CABLE Multi mode fibre .5 +/. Flame-retardant cables do not propagate fire. The greater the light transmittance. the cables must withstand the test specified in IEC standard 60332-3 or IEC 60332-1.3 for pH and 10 mikroS for conductivity. measured from the upper support. All Helkama cables comply with the most severe requirements of category A. highly flame-retardant and has low smoke emission. IEC 60331-2 Test method for fire with shock at a temperature of at least 830 °C for 90 minutes for cables of rated voltage up to and including 0. Requirements: 60 % light transmittance Un 3A Fire-resistant IEC 60331-1 Test method for fire with shock at a temperature of at least 830 °C for 90 minutes for cables of rated voltage up to and including 0.5 m Sheathing material: Test on bunched cables IEC 60332-3 Burning is allowed up to max. To meet the requirements as halogen-free the halogen content of the material may not exceed 0. 1m 2m IEC 60332-1 is the test for single insulated wire and cable.0 kV and with an overall diameter exceeding 20 mm. It has excellent mechanical and electrical characteristics. 3. B and C. All materials are halogen-free.5 litres/m 20 min IEC 60754-2 determines the degree of acidity of gases evolved during combustion. This material is halogen-free.5 meters from the burner within specified time.5 litres/m 40 min C 1.0 kV and with an overall diameter not exceeding 20 mm. highly flameretardant and has low smoke emission. The requirement for passing the test is that after the burner has been removed the cables must extinguish themselves. Burning may not occur more than 2.5 m XLPE stands for cross-linked polyethylene compound. 830 °C / 90 min gas burner 500 mm 110 mm .6/1. Burning time describes how long the burner is directed towards the bunch of cables. the better the visibility. 50 mm of the cable. 4m 2. This material is halogen-free. 550 600 mm mm Flame-retardant To be flame-retardant. 5/2014 The designation SHF2 stands for oil resistant thermosetting compound. and is determined on the basis of halogen content and the acidity of gases of a cable. and are self-extinguishing.5 m from the burner as shown in the figure.5 % or 5 mg/g. 2. such as chlorine and fluorine. Halogen-free Halogen-free refers to the absence of halogens.6/1. must remain unburned after the specified time. The oil resistance is demonstrated by immersion in IRM902 oil for 24h at 100°C. The designation SHF1 stands for thermoplastic compound. Definition of terms: Oil resistance Sheathing material is oil resistant according to method IEC 60811-2-1 and requirements from IEC 60092-359/SHF2. The limit values are 4.TECHNICAL INFORMATION 78 GENERAL INFORMATION Insulation material: The following designations are used for insulation materials in this catalog. defined by different limits for flammable material and burning times. Smoke emission Smoke emission refers to visibility in a fire. Test procedure and requirements according to the picture below. IEC 60332-3 is the test for bunched wires and cables and has three categories A. 27m3 cube smoke chamber Min. 50 mm 475 mm Category Amount of burning material Burning time A 7 litres/m 40 min B 3. When tested in accordance with IEC 61034-1 (test method) and IEC 61034-2 (test requirements) the smoke emission of a cable during fire must not exceed the following values. IEC 60754-1 determines the halogen content of the material. 1 – 40 40. Y/G = Yellow/Green 3-cores 1 2 3 1.8/3kV LKSM-VFD 1-core BK 3-cores BN BK Black numbers on white base 4-cores to 37-cores GY Black numbers on white base 3-cores + 3-ground cores Y/G BN BK Y/G GY Y/G 5/2014 Cable outer diameter. BN = Brown. mm.0mm ±1.79 Recommended minimum bending radius. BK = Black. ( R ) : Radius (R) Outer diameter (D) DIAMETER TOLERANCE During installation During installation Fixed installation Fixed installation R = 6x D R = 9x D R = 4x D R = 6x D LKSM-HF LKSM-EMC LKSM-VFD LKMSM-HF LKAM-HF LKM-FRHF LKSM-FRHF LKAM-FRHF RFE-HF RFE-HF(i) RFA-HF RFA-HF(i) RFE-FRHF RFE-FRHF(i) RFA-FRHF RFA-FRHF(i) During installation Fixed installation R = 9x D R = 6x D Tolerance ±0.0mm CORE IDENTIFICATION (according to HD 308 S2) 250V Pair number 1 2 3 4 5 6 0. 5-cores GY Y/G BU BN BU BN Y/G BN GY BK GY BK 1 3 Y/G BU GY BN BK 3 Y/G 4 6 5 4 250V LKSM-HF 7-cores and above 2-cores 1 G-type (with earth conductor) 2 2 2 7 6 1 5 Black numbers on white base 2 1 3 4 5 Black numbers on white base Last core yellow/green.1 – 30 < 25mm > 25mm < 25mm > 25mm TECHNICAL INFORMATION BENDING RADIUS LKM-HF LKMM-HF LKEM-HF . Black numbers on white base BU = Blue.6/1kV a b 1 3 5 7 9 11 2 4 6 8 10 12 Normal type 1-core BK 2-cores BN BU 3-cores BN BK 4-cores etc.5mm ±1. 30. GY = Grey. mm.1 – 50 50. 1 – 10 10.1 – 20 20.0mm ±2.5mm Cable outer diameter.1 – 60 Tolerance ±2.5mm ±3. 7 12 15 21 27 35 50 66 86 107 137 168 199 232 267 300 355 407 0.30 5 7 9 1 2 3 4 5 7 10 12 14 16 19 24 27 37 1.40 7 9 12 0.5mm2 2.58 +80°C 0.37 6 8 11 0.TECHNICAL INFORMATION 80 CURRENT RATING "Current rating (A) at an ambient temperature of 45°C according to the standard IEC 60092-352 0.35 6 8 11 0.7 13 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421 0.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 For class 5 conductor cables Size N Factor.00 +50°C 0. Continuous service for a cable is to be considered as a current-carrying service (with constant load) having a duration longer than three times the thermal time constant of the cable.58 10 13 17 23 29 41 55 71 89 0.05 +45°C 1.e.88 +60°C 0.47 .7 13 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421 0. longer than the critical duration(see short time duty)." Current carrying capacities in continous service at maximum rated conductor temperature of +90°C.85 15 20 26 34 44 61 82 108 133 167 206 249 288 331 377 444 511 0.33 6 7 10 0.46 8 11 14 0.64 +75°C 0. For class 2 conductor cables Size N 1 2 3 4 5 7 10 12 14 16 19 24 27 37 1 18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601 0.41 7 9 12 0.52 9 12 16 0.0mm2 1.35 6 8 11 0.10 Factor.52 9 11 16 0.44 8 10 13 0.74 +70°C 0.44 7 10 13 0.58 10 13 17 23 30 42 56 74 91 0. n 1. 1.0mm2 +40°C 1.5mm2 2.40 7 9 12 0.37 7 9 11 0.82 +65°C 0. n 5/2014 For continuous service.33 6 7 10 0.94 +55°C 0.41 7 9 12 0.7 12 15 21 27 35 50 66 86 107 137 168 199 232 267 300 355 407 0.46 8 10 14 0.6/1 kV +90°C marine cables.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 1 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582 0. i.30 5 7 9 Ambient temperature Correction factor +35°C 1.85 14 19 26 33 43 60 80 105 130 167 204 241 281 324 365 431 495 0. 5 0.4 0.2 14.3 5.0 60.5 0.0 0.8 3.0 0.5 2.6 2.3 0.3 2.4 97.9 0.3 Short circuit current in kA 10 0. normal.6/1kV cable with XLPE or HF90 with maximum operating temperature of +90°C (Tb) and short circuit temperature of +250°C (Tk). Cross-section of the conductor in mm2.0 19.8 8.5 0.5 12. TECHNICAL INFORMATION Maximum permissible short circuit current.0 24.3 0.2 4.4 16.8 17.9 8.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 0.3 2. °C Formula 1: For 0.7 2.2 8.1 7.3 7.2 3.2 0.81 SHORT CIRCUIT CURRENT Based on formula: Ik = 226 X S t X S t X In 234 + Tk 234 + Tb Formula 1: Ik = 146 Ik S t Tk = = = = Maximum permissible short circuit current.9 0.6 3.6 0.5 1 2 3 0. Cross-section of the conductor in mm2 1.0 39.0 24.5 2.2 11.7 1.3 0.3 1.1 1.6/1 kV +90°C marine cables.5 1.1 31.1 0. short circuit.2 0.2 5.1 15.2 1.2 0.0 10.0 3.6 49.9 43.6 35.1 0.2 0.5 6. Maximum rated conductor temperature. °C Tb = Maximum rated conductor temperature.6 13.3 1.2 0.9 9.2 5.0 25.1 0.1 0.5 12.7 1.5 10.1 0.4 5.8 20.2 49.1 13.0 21.2 27.4 78.4 10.8 0.2 61.3 22.6 38.2 4.4 0.2 0. Duration of the short circuit in s.9 5/2014 SHORT CIRCUIT FACTOR Short Circuit Factor can be calculated by following formula: SHORT CIRCUIT FACTOR = Duration of the short circuit in s. SHORT CIRCUIT CURRENT CURRENT RATING .3 3.1 0.6 2.9 15.3 0.2 0.3 5.6 0.8 1.9 31.5 11.2 7.0 1. 0.9 19.3 5.1 3.8 31. min.012 1. min.061 1.534 1.39 4.403 1.6/1 kV +90°C marine cables.042 1.48 14.06 4.433 1.12 1-exp(-ts/T) ( ts = service time. Service time. mm.6 48.058 1.058 1.058 1.26 10. If a cable is intended to supply motor or equipment operating for periods of half an hour or one hour.625 1. may be increased using the relevant correction factors given by formula: correction = factor 1.518 1.75 3.058 1.245 x d 1.127 1.058 1.554 1. Fi= 1-exp(-10/T) 1-exp(-4/T) Overall diameter of the cable. duration.0 24.058 1.9 72.058 1.705 1.058 1.254 1.170 1.2 35.5 107 145 185 Correction factor.208 1.2 61.058 1. Intermittent service Correction factor for intermittent service according to the standard IEC 60092-352 The correction factor given hereby has been roughly calculated for periods of 10 min.105 1.735 1.24 4. min. of which 4 min are with a constant load and 6 min without load. 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 Time Critical constant. 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 1.058 1.59 2.6 0.059 1. 30 60 T 3x T 1.35 5/2014 (d = Overall diameter of the cable.059 1.) T = 0.76 5.001 1.08 1. min.058 1.341 0. Intermittence ratio = 40%. T = Time constant.058 1.5 41.TECHNICAL INFORMATION 82 SHORT TIME DUTY Short time duty according to the standard IEC 60092-352 0.273 1.058 1.544 . mm.058 1.083 1.) Overall diameter of the cable.058 1.126 1.78 6.490 1. Correction factor. mm.87 3.173 1. min.2 12. its current rating given in table “current rating”.15 2. Intermittence period = 10min.000 1.245 0.3 16.058 1.066 1.242 1.255 1.46 8.2 14.058 1. 53 0.135 0.75mm2 1.42 0.44 3.177 0.3 7.524 0.164 0.153 0.88 3.61 0.1 51.09 1.7 33.4 9.857 0.798 0. LKM-FRHF.0641 33.4 12.987 0.1 7.5 mm2 Resistance at +20°C ohm/km Maximum conductor temperature.6 *) at +90°C **) For continuous service (single core.5mm2 2.44 1.0660 18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601 0.608 0.11 0.91 1.493 0.0 12.7 57.19 0.995 0.6 8.9 18. RFE-FRHF(i).0991 0.3 8.14 0. LKSM-HF FLEX.0828 0.29 0.727 0.13 0.9 17.492 0.30 0.082 66.18 6.75 mm2 1.206 0.17 0.411 0.0mm2 1.06 3.668 0.168 0.102 0.575 0. LKEM-HF (Cables with class 5 conductor) TECHNICAL INFORMATION Cable types: LKM-HF.6 14.64 0.2 24. RFE-HF(i).11 0.193 0.706 0.153 19. RFA-FRHF.4 14.1088 0.41 4.33 1.129 0.49 0.0mm2 1.41 0.85 1.47 0.106 0. ambient temperature +45°C) ***) at maximum current rating for continuous service at +45°C 5/2014 Cable types: LKM-HF FLEX.15 0.93 2.3 103.10 1.38 2.08 1.95 3.294 0.0754 0.683 0.2 30.78 0.0961 0.21 0.226 0.1 12.9 11.10 0.36 0.088 0.4 28.1 28.12 0.1 88. °C Resistance at +45°C ohm/km Voltage reduction mV/Am at +45°C Resistance at +90°C ohm/km Voltage reduction mV/Am at +90°C 40.1 15.5 33. LKSM-HF.425 0.136 0.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 Resistance at +20°C ohm/km Resistance at +90°C ohm/km Voltage reduction mV/Am *) Resistance at +45°C ohm/km Current rating A **) Voltage reduction mV/m ***) 18.8 90 90 90 44.086 0.21 0. RFE-HF.161 0.3 49.80 0.329 0. RFE-FRHF.268 0.0766 46.205 0.30 1.0601 23.0 10.070 14 17 22 30 39 50 71 94 123 153 196 240 284 331 381 429 507 582 0.99 1.25 0.195 0.87 3.14 0.3 32.14 5.67 2.26 0.124 0. RFA-HF(i).01 1.9 13.6 21.984 0.72 0.85 4.35 0.492 0.299 0.33 0.61 3.079 Size 0.6 8.62 2.0801 0.9 20.09 0.54 0.246 0.272 0.347 0.554 0.83 VOLTAGE DROP Size 1. LKSM-FRHF (Cables with class 2 conductor) .5 mm2 0.83 1.927 0.1264 0.116 0.386 0.18 0.8 7.34 0.24 0.08 Cable types: LKSM-HF 250V.316 0.2 16.0 19.270 0.158 0.253 0.98 4.45 5. LKAM-HF.0 66. RFA-FRHF(i) Size 0. RFA-HF.5 13.142 0.76 5.41 0.17 0.73 0.12 0.5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 Resistance at +20°C ohm/km Resistance at +90°C ohm/km Voltage reduction mV/Am *) Resistance at +45°C ohm/km Current rating A **) Voltage reduction mV/m ***) 26.212 0.5mm2 2.097 0.21 2.694 0.424 0.387 0.163 28.42 4.31 4.93 1.204 0.342 0.20 0.525 0.390 0.192 0.4 26.11 0.263 0. lastname@helkamabica. See latest updates on our webpage www..com . Fax +86 21 3365 5331 [email protected]. Shanghai 201401. Plot 1-2. +86 21 3365 5333.HELKAMA BICA OY Lakimiehenkatu 4 FI-20780 KAARINA Finland Tel.com 5/2014 Subject to change without prior notice. Ltd. 3111 Huan Cheng West Road Fengxian District.cn www.fi Helkama Bica (Shanghai) Co. +358 2 410 8700 Fax +358 2 237 2428 firstname. MinHang Export Processing Zone No.fi sales@helkamabica. China Tel.helkamabica.
Copyright © 2024 DOKUMEN.SITE Inc.