HAZWATCH Supplement

March 28, 2018 | Author: Andres Giraldo Moreno | Category: Battery Charger, Battery (Electricity), Electrical Connector, Relay, Volt


Comments



Description

HazardWatch Integrated Fire and Gas Alarm System SupplementThe information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General Monitors. Instruction Manual 11-05 General Monitors reserves the right to change published specifications and designs without prior notice. MANTS4000 Part No. Revision MANHAZARDWATCH 1/09-05 HazardWatch This page intentionally left blank ii HazardWatch Table of Contents 1.0 HAZARDWATCH SPECIFICATIONS AND DATA SHEETS ................................................. 6 1.1 Local Panel Equipment ..............................................................................................................6 1.1.1 PLC Equipment .............................................................................................................6 1.1.2 Local HMI ....................................................................................................................12 1.1.3 Communication Modules ............................................................................................14 1.1.3.1 Controlnet Module..........................................................................................14 1.1.3.2 Ethernet Module.............................................................................................15 1.1.3.3 Modbus Module..............................................................................................15 1.1.4 Fiber Optic Communication Module............................................................................16 1.1.5 DC to DC Converter ....................................................................................................16 1.1.6 DC Power Supply and Batteries .................................................................................17 1.1.7 Current Shunt and MV Transmitter .............................................................................20 1.1.8 Battery Disconnect Switch and Polarized Connectors................................................22 Coaxial Cable...........................................................................................................................24 Fiber Optic Cable .....................................................................................................................24 Central Station Equipment .......................................................................................................24 1.4.1 UL 864 Computer Station ...........................................................................................24 1.4.2 Central Station UPS ....................................................................................................25 1.4.3 Central Station Fiber Optic Converter.........................................................................27 1.4.4 Central Station Printer.................................................................................................27 GMI Field Devices....................................................................................................................28 1.5.1 GM S4000C Combustible Gas Detector .....................................................................28 1.5.2 GM S4000T H2S Gas Detector ..................................................................................30 1.5.3 GM IR2100/IRFMD IR Gas Detector ..........................................................................31 1.5.4 GM IR 5000 Open Path Gas Detector ........................................................................34 1.5.5 GM FL3100/3101UV/IR Flame Detector.....................................................................35 1.5.6 GM FL3102 DFIR Flame Detector ..............................................................................37 Smoke and Thermal Fire Detection Equipment.......................................................................38 1.6.1 Pyrotronics DI-3 Ionization Type Smoke Detector......................................................38 1.6.2 Pyrotronics PE-11 Photoelectric Type Smoke Detector .............................................39 1.6.3 Pyrotronics DT-11 Thermal Detector ..........................................................................40 1.6.4 Kidde Fenwal Detect-a-fire Thermal Detector ............................................................41 1.6.5 Apollo Series 60 Ionization Type Smoke Detector .....................................................42 1.6.6 Apollo Series 60 Photoelectric Type Smoke Detector ................................................44 Audible Devices .......................................................................................................................46 1.7.1 Federal Signal Model 50 GC Selectone Horn.............................................................46 1.7.2 Federal Signal Model 300 GCX Selectone Horn ........................................................46 1.7.3 Federal Signal Model 300X & 302X Selectone Horn..................................................47 1.7.4 Federal Signal Model 41-X Selectone Horn ...............................................................48 1.7.5 MEDC XB3 Horn .........................................................................................................49 1.7.6 Notifier Spectralert Horn .............................................................................................54 1.7.7 Notifier Spectralert Horn .............................................................................................54 1.7.8 Crouse Hinds ESR Fire Alarm Bell .............................................................................54 1.7.9 Pyrotronics MBDC-6 Fire Alarm Bell...........................................................................57 Visual Devices..........................................................................................................................58 1.8.1 Federal Signal Model 191 X Strobe Light ...................................................................58 1.8.2 Federal Signal Model 151 XST Strobe Light ..............................................................58 1.8.3 Federal Signal Model 27XST Strobe Light .................................................................59 iii 1.2 1.3 1.4 1.5 1.6 1.7 1.8 ....8................7 Federal Signal Model 121 X Rotating Light ..HazardWatch 1................................................................62 MEDC XB-11 Strobe Light .....................67 iv ....8.............6 1..............................................................................8.........60 MEDC XB-3 Strobe Light .........................................................4 1.............................8.........................................65 Notifier Spectralert Strobe.5 1....... HazardWatch v . 5 oz) IEC 60068-2-1 (Test Ad. Unpackaged Shock): 30g IEC60068-2-27 (Test Ea. Unpackaged Shock): 50g CISPR 11: Group 1. Class A IEC 61000-4-2: 6kV contact discharges 8kV air discharges IEC 61000-4-3: 10V/m with 1kHz sine-wave 80%AM from 30MHz 2000MHz 10V/m with 200Hz 50% Pulse 100%AM at 900Mhz 10V/m with 200Hz 50% Pulse 100%AM at 1890Mhz IEC 61000-4-4: ±4kV at 5kHz on power ports ±4kV at 5kHz on communications ports IEC 61000-4-5: ±1kV line-line (DM) and ±2kV line-earth (CM) on AC power ports 6 Storage Temperature: Relative Humidity: Vibration: Operating Shock: Non-Operating Shock: Emissions: ESD Immunity: Radiated RF Immunity: EFT/B immunity: Surge Transient Immunity: .0 HazardWatch Sheets 1.HazardWatch 1. Operating Dry Heat) IEC 60068-2-14 (Test Nb. Operating): 2g @ 10-500Hz IEC60068-2-27 (Test Ea. Un-packaged Nonoperating Thermal Shock) -40 … 85°C (-40 … 185°F) IEC 60068-2-30 (Test Db. Un-packaged Nonoperating Damp Heat): 5% … 95% non-condensing IEC60068-2-6 (Test Fc.2 g (0. Operating Cold) IEC 60068-2-2 (Test Bd.1. Operating Thermal Shock) 0 … 60°C (32 … 140°F) IEC 60068-2-1 (Test Ab.1 Local Panel Equipment ControlLogix Controller Specifications . Un-packaged Non-operating Dry Heat) IEC 60068-2-14 (Test Na.1784-CF64 Industrial CompactFlash Card Specifications: User Available Memory: Nonvolatile Memory: Weight: Operating Temperature: 64M bytes Yes 14.1 PLC Equipment Specifications and Data 1. Un-packaged Non-operating Cold) IEC 60068-2-2 (Test Bb. Certificates. Industrial Immunity • EN 61326. 1756-L63/B Use this battery: 1756-BA1 (0. D Hazardous Locations CE European Union 89/336/EEC EMC Directive. Meas.50g lithium) Certifications: When marked.1756L55M13.CP3 or 1747-CP3 serial cable * Use this Conductor Category information for planning conductor routing.ab. 1756L55M16. Division 2 Group A. Refer to Publication 1770-4. 1756-L55M24 1756-L61/A./Control/Lab.59g lithium) 1756-BA2 (0. Catalog Number 1756-L1 Certificate Description UL UL Listed Industrial Control Equipment CSA CSA Certified Process Control Equipment CSA CSA Certified Process Control Equipment for Class I. 1756-L62/B. 1756-L55M14. 1756-L62/A. 1756-L63/A 1756-L61/B. compliant with: EN 50021. B.1.59g lithium) 1756-BA1 (0. Industrial Immunity • EN 61000-6-4. 1756-L1M3 1756-L55.. compliant with: AS/NZS CISPR 11.59g lithium) 1756-BA1 (0. 1756L55M23. Protection "n" (Zone 2) 7 . the components have the following certifications.HazardWatch ±2kV line-earth (CM) on communications ports IEC 61000-4-6: 10Vrms with 1kHz sine-wave 80%AM from 150kHz 80MHz Enclosure Type Rating: None (open-style) Isolation Voltage: 30V Series A controllers: Tested to withstand 500V ac for 60 seconds Series B controllers: Tested to withstand 720V dc for 60 seconds Wiring Category*: Category 3 on communication ports Programming Cable: For 1756. Industrial Emissions C-Tick Australian Radio communications Act.com for Declarations of Conformity. 1756-L55M22. Industrial Emissions EEX European Union 94/9/EC ATEX Directive. See the Product Certification link at www. Potentially Explosive Atmospheres. 1756-L1M1. and other certification details. 1756-L55M12. compliant with: • EN 50082-2. 1756-L1M2. Industrial Requirements • EN 61000-6-2. Industrial Automation Wiring and Grounding Guidelines Conducted RF Immunity: Replacement Battery For this component: 1756-L1. C. 25 BTU/hr 19.4 oz) 2M bytes 478K bytes Yes*** 1756-L61/B *Data and logic memory stores: tags other than I/0.1V dc: @ 24V dc: Power Dissipation: Thermal Dissipation: Weight: 1. @ 60°C (Linear derating) 8A max. logic routines.3W @ 60oC 11.HazardWatch ControlLogix Controllers Specifications: Catalog Number: Memory Data and Logic: U/0**: Nonvolatile Memory Backplane @ 5. ***Requires a 1784-CF64 Industrial CompactFlash card. and communication with OPC/DDE tags that use RSLinx software (also uses data and logic memory).5 11. communication with workstations. Off-State Leakage Current: Output Delay Time OFF to ON: ON to OFF: Diagnostic Functions: Short trip: No load: Output verification: Pulse test: 8 16 (8 points/common) 1756 ControlLogix Chassis 250mA @ 5.2V dc @ 2A 1mA per point 1ms maximum 5ms maximum 8A 180ms minimum 10A 120ms minimum OFF STATE detection only ON STATE detection only User selectable maximum pulse width . @ 30°C & 4A max.35 kg (12. communication via Message (MSG) instructions. 1756-OB16D Specifications: Number of Outputs: Module Location: Backplane Current: Max. repeatable every 1s 3mA per point 1. @ 60°C (Linear derating) 4A for 10ms each. and communication with OPC/DDE tags that use RSLinx software (also uses I/O memory) **I/O memory stores: I/O tags.20A 14mA 3. produced.64W) 3. consumed tags.1V dc & 140mA @ 24V dc (Total backplane power 4. Power Dissipation (Module): Thermal Dissipation: Output Voltage Range: Output Current Rating Per Point: Per Module: Surge Current per Point: Minimum Load Current: Maximum On-State Voltage Drop: Max. produced tags.2-30V dc 2A max. @ 30°C & 1A max.9 BTU/hr 0. or consumed tags. Marked for all applicable directives Maximum wire size will require extended housing . The interior of this enclosure must be accessible only by the use of a tool. D FM . 1756-IB32. NOTE: The ControlLogix system must be mounted within a suitable enclosure to prevent personal injury resulting from accessibility to live parts. B.4 inch-pounds (0. 3 Screwdriver Blade Width for RTB: 1/8 inch (3. Refer to publication 1770-4.1 “Industrial Automation Wiring and Grounding Guidelines.7s maximum.HazardWatch Time stamp of diagnostics: Configurable Fault States/Point: Configurable States in Program: Mode/Point Scheduled Outputs: Fusing: Reverse Polarity Protection: Isolation Voltage Group to group: User to system: RTB Screw Torque (Cage clamp): Module Keying (Backplane): RTB Keying: RTB and Housing: Environmental Conditions Operating Temperature: Storage Temperature: Relative Humidity: Conductors Wire Size: +/. reference to the Coordinated System Time Electronically fused per point None . 100% tested at 2546V dc for 1s (250V ac max.1V dc & 2mA @ 24V dc (Total backplane power 0. Division 2.2mm) maximum Agency Certification: UL -Listed Industrial Control Equipment (When product or packaging is marked) CSA . C. Division 2. Group A. continuous voltage between groups) 100% tested at 2546V dc for 1s 4. outputs may be damaged. Input Module Specifications: Number of Inputs: Module Location: Backplane Current: Maximum Power Dissipation (Module): 9 4.81W) .1756-TBE. D CE .4Nm) maximum Software configurable User defined mechanical keying 36 Position RTB (1756-TBCH or TBS6H)1 0 to 60°C (32 to 140°F) -40 to 85°C (-40 to 185°F) 5 to 95% non-condensing 2-14-gauge (2mm2) stranded 1 3/64 inch (1. Group A.5W @ 60oC 32 (16 points/common) 1756 ControlLogix Chassis 150mA @ 5.Approved Class I. ON or OFF (OFF is the default) Hold Last State.If module is wired incorrectly. B. C.2mm) insulation maximum Category: 12. Use this conductor category information for planning conductor routing as described in the system level installation manual. ON or OFF (OFF is the default) Synchronization within 16.Approved Class I.1ms Hold Last State. without activation) User selectable (100_s minimum/750ms maximum) Yes 250V maximum continuous/100% tested at 2546V dc for 1s 250V maximum continuous/100% tested at 2546V dc for 1s 4.5mA 5V dc 1. 2ms.67kΏ Programmable filter:0ms.2V dc: Maximum Off-State Voltage: Maximum Off-State Current: Maximum Input Impedance @ 31.5mA 5. Operating): 10 Storage Temperature: Relative Humidity: Vibration: . IEC 60068-2-14 (Test Na. Operating Cold) IEC 60068-2-2 (Test Bd.4 inch-pounds (0. 1ms or 2ms 1ms maximum plus filter time Programmable filter: 0ms.200µs 250mA peak (decaying to <37% in 22ms.4Nm) maximum Software configurable User defined mechanical keying 36 Position RTB (1756-TBCH or TBS6H)(1) IEC 60068-2-1 (Test Ad.mA 5. Un-packaged Nonoperating Damp Heat): 5 to 95% non-condensing IEC60068-2-6 (Test Fc. 1ms.2V dc 24V dc 2.37 BTU/hr @ 60oC 10-31. Operating Dry Heat) IEC 60068-2-14 (Test Nb. Un-packaged Nonoperating Thermal Shock): –40 to 85°C (–40 to 185°F) IEC 60068-2-30 (Test Db. Un-packaged Nonoperating Cold) IEC 60068-2-2 (Test Bb. 9ms or 18ms 2ms maximum plus filter time Software configurable +/. Operating Thermal Shock) 0 to 60°C (32 to 140°F) IEC 60068-2-1 (Test Ab.2V dc: Input Delay Time OFF to ON: Hardware delay: ON to OFF: Hardware delay: Diagnostic Functions Change of state: Time stamp on inputs: Short/Inrush Current: Cyclic Update Time: Reverse Polarity Protection: Isolation Voltage Group to group: User to system: RTB Screw Torque (Cage clamp): Module Keying (Backplane): RTB Keying: Field Wiring Arm and Housing: Environmental Conditions Operating Temperature: 16. Un-packaged Nonoperating Dry Heat).HazardWatch Thermal Dissipation: On-State Voltage Range: Nominal Input Voltage: ON-State Current @ 10V dc: @ 31. Industrial Emissions EEx4 European Union 94/9/EEC ATEX Directive.HazardWatch 2g @ 10-500Hz IEC60068-2-27 (Test Ea Unpackaged shock): 30g 50g CISPR 11: Group 1. B.5kHz on signal ports Surge Transient Immunity: IEC 61000-4-5: ±1kV line-line (DM) and ±2kV line-earth (CM) on power ports ±1kV line-line (DM) and ±2kV line-earth (CM) on signal ports Conducted RF Immunity: IEC 61000-4-6: 10Vrms with 1kHz sine-wave 80%AM from 150kHz to 80MHz Enclosure Type Rating: None (open-style) Conductors . Industrial Emissions C-Tick4 Australian Radio communications Act. D Hazardous Locations CE4 -European Union 89/336/EEC EMC Directive. Industrial Immunity EN 61000-6-4. compliant with: AS/NZS 2064. B./Control/Lab.2mm) maximum Certifications: UL -UL Listed Industrial Control Equipment (When product is marked) CSA -CSA Certified Process Control Equipment CSA -CSA Certified Process Control Equipment for Class I. D Hazardous Locations FM. compliant with: EN 50021. Class A IEC 61000-4-2: 6kV contact discharges 8kV air discharges Radiated RF Immunity: IEC 61000-4-3: 10V/m with 1kHz sine-wave 80%AM from 30MHz to 1000MHz 10V/m with 200Hz 50% Pulse 100%AM at 900Mhz EFT/B Immunity: IEC 61000-4-4: ±4kV at 2. C.08 sq. Potentially Explosive Atmospheres. Industrial Immunity EN 61326. Industrial Requirements EN 61000-6-2. 3 Screwdriver Blade Width for RTB: 1/8 inch (3. Maximum wire size will require extended housing .. Meas.2mm) insulation maximum Category: 12.1756-TBE. mm) stranded1 3/64 inch (1.324 to 2.5kHz on power ports ±4kV at 2. Shock: Operating: Non-operating: Emissions: ESD Immunity: 2. C. Protection “n” 1. Division 2 Group A. Use this conductor category information for planning conductor routing as described in the 11 .Wire Size: #22 to #14 AWG (0. compliant with: EN 50082-2.FM Approved Equipment for use in Class I Division 2 Group A. 1. B.64 lb. B.0 A @ 5.57 lb.1 V 1. D CE -Marked for all applicable directives 1.4 in Color active matrix thin film transistor (TFT) 640 x 480. 3.1 Industrial Automation Wiring and Grounding Guidelines.260 kg (0.14 W 17. 2 USB ports.ab. extended: 128 MB Standard: 64 MB.293 kg (0.) UL -Listed Industrial Control Equipment CSA -Approved Class I.HazardWatch system level installation manual. Refer to publication 1770-4. C. 1 10/100 Mbps Ethernet port.com for Declarations of Conformity. ControlLogix ControlNet Bridge 1756-CNBR Specifications: ControlNet Interface Connectors: Cable: Ground isolation: Electrical Power dissipation: Thermal dissipation: Backplane current: Environmental Operational temperature: Storage temperature: Relative humidity: Physical Location: Weigh: Agency Certification (When product or packaging is marked) 2 BNC connectors for redundant media operation 1 NAP (RJ-45 8-pin with shield) Quad shield RG-6 coaxial cable Transformer 5. Group A. D FM .5 BTU/hr 1. 24 bit color Keypad. Division 2. See the Product Certification link at www.7 mA @ 24 V 0 to 60°C (32 to 140°F) –40 to 85°C (–40 to 185°F) 5 to 95% (without condensation) Any slot in a 1756 chassis 0. Division 2. extended: 128 MB 1 serial port. C.2 Local HMI PanelView Plus 1000 Specifications: Display Size: Type: Resolution: Input Method: Communication Options Flash Memory: RAM: I/O and Slots: Input Voltage: 12 Standard: 32 MB. Group A. 4.Approved Class I.) 0. 1 Compact Flash memory card slot DC: 18-32V dc 10. Certificates. or combination keypad/touch . touch. and other certification details. 3 lb. and user configurable non-RA networks Standard: 32 MB.8 x 12 in) Keypad or Keypad/Touch: 224 x 375 mm (8.) 2..95%. B..8 x 14.75 in) Touch: 2. 10…57 Hz.95%.17 in) Keypad or Keypad/Touch: 248 x 399 x 55 mm (9. C-UL approved. CE marked 0..77 x 15. Remote I/O. non-condensing @ 0.55°C Cutout Dimensions PanelView Plus Specifications: Display Size: Type: Resolution: Input Method: Communication Options: Flash Memory: RAM: I/O and Slots: Input Voltage: Operating Temperature: Storage Temperature: Humidity: Vibration – Operating and Non-Operating: Shock – Operating and Non-Operating PanelView Plus 1000 10... extended: 128 MB Standard: 64 MB... 24 bit color Keypad. non-condensing @ 0. 2g peak. extended: 128 MB 1 serial port..158°F) 5.70°C (13. 1 Compact Flash memory card slot DC: 18-32V dc 0. D. 4X*..9 kg (6.55°C (32..70°C (-13. 13. 2g peak. 57…500 Hz 25. 57…500 Hz 15g/30g 13 . Class 1/2/3 .4 in Color active matrix thin film transistor (TFT) 640 x 480.131F) -25.77 x 12.012 in p-p.158°F) 5. DH+.55°C 0. DH485. C.6 kg (5.Div 2 Groups A..17 in) Touch only: 224 x 305 mm (8..7 lb.. 2 USB ports.. or combination keypad touch ControlNet.HazardWatch Operating Temperature Storage Temperature: Humidity: Vibration – Operating Non Operating: Shock – Operating/ Non-Operating: Ratings: Certifications: Mechanical Weight: Dimensions Overall (H x W x D): Touch only: 248 x 329 x 55 mm (9.. IP54... DF1 Ethernet/IP. IP65 UL. 10…57 Hz.. touch..) 15g/30g NEMA Type 12.012 in pp.72 x 2.. 1 10/100 Mbps Ethernet port.97 x 2. 0 A @ 5. 13.1 V 1. Class 1/2/3 Touch: 2. 4X*. Division 2. D Marked for all applicable directives Marked for all applicable acts Approved class I.1. IP65 UL.14 W 17.) Keypad or Keypad/Touch: 2. D 0 to 60°C (32 to 140°F) –40 to 85°C (–40 to 185°F) 5 to 95% (without condensation) 5.3.77 x 15.3 Communication Modules 1.72 x 2.1. C.3 lb. B.7 mA @ 24 V V 2 BNC connectors for redundant media operation 1 NAP (RJ-45 8-pin with shield) Quad shield RG-6 coaxial cable Transformer 14 .9 kg (6.64 lb. Group A.97 x 2.) Touch only: 248 x 329 x 55 mm (9.8 x 14. IP54.17 in) Keypad or Keypad/Touch: 248 x 399 x 55 mm (9.HazardWatch Ratings: Certifications: Mechanical Weight Dimensions Overall (H x W x D) Cutout Dimensions NEMA Type 12.75 in) 1.293 kg (0.77 x 12. C. Group A. C-UL approved.5 BTU/hr 1.17 in) Touch only: 224 x 305 mm (8.) Listed Industrial Control Equipment Certified Process Control Equipment Certified Class I.1 Controlnet Module Module 1756-CNBR Specifications: ControlNet Interface connectors Cable Ground isolation Electrical Power dissipation Thermal dissipation Backplane current Environmental Operational temperature Storage temperature Relative humidity Physical Location: Weight: Agency Certification (When product or packaging is marked) Any slot in a 1756 chassis 0.7 lb.8 x 12 in) Keypad or Keypad/Touch: 224 x 375 mm (8.6 kg (5. B. Division 2. Division 2.D N223 0 to 60° C (32 to 140° F) -40 to 85° C (-40 to 185° F) 5 to 95%.HazardWatch 1. B.1V DC 3mA @ 24V DC from I/O chassis backplane 3.150 Hz 5-95% (w/o condensation) Module Status Backplane Transfer Status Application Status Serial Activity and Error LED Status DB-9M PC Compatible RS-232 only Hardware handshaking 15 Configuration Serial Port (PRT1): .65W maximum 30g operational 50g non-operational 5g from 10 to 150 Hz 802. D Marked for all applicable directives Marked for all applicable acts Approved Class I.3. Division 2. Groups A. C. non-condensing Listed Environmental Operating Temperature Storage Temperature Relative Humidity 1.3.2 Ethernet Module Specifications: Module Location: Maximum Backplane Current Load: Power Dissipation: Shock (Unpackaged) Vibration (Unpackaged) Conductors Wiring Category Ethernet Connector User Manual Publication Agency Certifications When product is marked Industrial Control Equipment Any slot in the ControlLogix chassis 700mA @ 5.3 compliant .C.twisted pair 2(1) RJ45 Category 5 1756-UM050 Certified Process Control Equipment Certified Class I.3 Modbus Module Modbus Master/Slave Communications Interface Module MVI56-MCM Specifications: Local or Remote Rack Backplane Current Load: Operating Temperature: Storage Temperature: Shock: Vibration: Relative Humidity: LED Indicators: 800 mA @ 5 V 0 to 60 Deg C (32 to 140 Deg F) -40 to 85 Deg C (-40 to 185 Deg F) 30g Operational 50g non-operational 5 g from 10 .1. Groups A.B.1. . 1756 Chassis Installation 10.1. 24 VDC. Base Plate AC500V 1minute.14” D (26. Cutoff current 10mA.1.8 Amps (Typical 120/220 VAC. DC500V 50 ML2 min (20±15°C) Output Environment Operating Temp.5 DC to DC Converter Cosel Power Module CBS100 Specifications: Isolation Input Input Output DC1.36cm H x 4. DC500V 50 ML2 min (20±15°C) Case Pin.76” W* x 6. 500V.38” H x 1. or AC1.60cm D * Add 1.4 Fiber Optic Communication Module PheonixDigital Specifications: Fiber Optic Cable Type: Mating Connector: Transmit Launch Power: Receive Sensitivity: Power Supply Plug-In Modules: Standalone Panelmount Modules: Environmental Operating Temperature: Storage Temperature: Relative Humidity: Dimensions 1771 Plug-In Modules: 1746 Plug-In Modules: 1756 Plug-In Modules: Standalone. 000V 1 minute. 1746 Chassis Installation Single Slot. Multimode).47cm W* x 15. non-condensing +5 VDC. or AC1. -18dbm (Singlemode) -32dbm 1.. 10 Watts Multimode or Singlemode ST or SMA 15dbm (Typical. Panelmount: Modules: Single Slot. 500V. RJ45 (RJ45 to DB-9M PC Compatible connector is supplied) RS232/422/485 jumper selectable RS232 handshaking configurable 500V Optical isolation from backplane 1.54cm) for rear panel flange 0° to 60° C (32° to 140° F) -40° to 85° C (-40° to 185° F) 0 to 95% RH.HazardWatch Application PRT2): Serial ports (PRT1. 1. or 125 VDC.. Cutoff current = 10 mA. 1771 Chassis Installation Single Slot. Humid and Altitude 16 -40 to 100°C (On aluminum base plate). 000V 1 minute. Base Plate DC1. DC500V 50 ML2 min (20±15°C) Case Pin. Cutoff current = 10 mA. 20 – 95% RH (Non condensing) (Refer to DERATING .00” (2. EN60950 1.1 m/s2 (20G).000 feet) max Storage Temp. 60 minutes each along X.5% of setting from no load to full load over the specified input voltage. 24. 11ms. once each along X. 3 minutes period. DC Voltage Regulation and Current Limit Protection DC Amps: 3 to 400 amperes DC Volts: 12.208.000m (30.6 DC Power Supply and Batteries LaMarche Power Supply /Battery Charger Specifications: Electrical AC Input Voltages: Single Phase 60Hz: 120.0m/s2 (5G). please consult the factory. Y. Case specifications are subject to change due to innovative product development and design.380 or 415 Three Phase 60Hz: 208.7X 61. heat radiation from the aluminum base plate to the attached heat sink) UL60950. Mounting flanges 17 Output Power Protection: DC Output Voltages: Output Filtering: DC Voltage Regulation: Environmental Operating Temperature: Dimensions: Mounting: .240. 48 & 130VDC (Others available such as 32 & 36VDC) 30mV RMS for single phase models and 100mV RMS for three-phase models when connected to a battery with an ampere-hour capacity of four times the output current capacity of the charger.380 or 415 DC Fuse. 3. and Z axis 196. Plus or minus 0. Y.g. and Z axis Safety Agency Approvals Others Case Size/Weight Cooling Method 57. 9. frequency and ambient temperature ranges.000m (10. 49. C-UL.480 or 575 Single Phase 50Hz: 220/240.HazardWatch CURVE). 0 to 50O C (32 to 122O F) Storage Temperature: -40 to 85O C (-40 to 185O F) Relative Humidity: 0 to 95% (non-condensing) Overall dimensions and weights are listed here-in.480 or 575 Three Phase 50Hz: 220/240. Floor or wall units are available. Humid and Altitude Vibration Impact -40 to 100°C.240. When space requirements are critical.1.9 x 12.000 feet) max 10-55 Hz. 20 – 95% RH (Non condensing).0mm (WX HXD)/83g max Conduction cooling (e. L. 65 in. (with temperature compensation) +74°F (23°C) to +80°F (27°C) 13. Fire Alarm System / Power Supply Application: CSA Rectifiers: UPS12-370 – Specifications: Cells Per Unit Voltage Per Unit Weight Electrolyte Max.5% P-P of float charge voltage recommended for best results Maximum voltage allowed = 1. Charge. Guide UTRZ Std. 85 Ah @ 10 hr.25" (6mm) bolt.1564 File S2768. File E 25701.0025 Ohms 391 watts per cell at the 15-minute rate to 1.80 volts per cell @ 20°C (68°F). 100 Ah @ 20 hr. 60 Hz Ω Capacity 6 12.L. Inter unit connectors.Guide BBHZ Std. C22. -40°F (-40°C) to +160°F (71°C). (5. rate to 1.28" clearance hole to accept 0.1 sec 0. Finished with environmentally safe water based ANSI 61 gray baked enamel.88 N-m). -10°F (-23°C) to + 140°F (60°C). Pretreated with three-step iron phosphate wash and de-ionized rinse.5 to 13. Absorbed H2SO SG = 1. racks and cabinet systems are available. 34 kg.300 800 Amps 5100Amps @ 0. (7. 1481 File LR14209. 107 Agency Approvals U.-lbs. rate to 1. 52 in.No. For higher temperatures the time interval will be shorter. Std.75 volts per cell @ 77°F (25°C).No. Industrial Battery Charger: U.8 VDC/unit Average at 77°F (25°C) 0.5% RMS or 1.4 N-m). Discharge Current Short Circuit Current Ohms Imped.4% RMS (4% P-P) Maximum current allowed = 5 amperes RMS (C/20) Dynasty UPS batteries may be stored for up to 6 months at 77°F (25°C) and then a freshening charge is required.-lbs.8 VDC/unit Average at 77°F (25°C) C/5 amperes (20 amperes @ 100% depth of discharge) @ 20 hour rate. Discharge.4 to 14.HazardWatch Finish: are supplied as integral part of cabinet back plate on wall mounted models.84 74 lbs.67 volts per cell at 77°F (25°C). Operating Temperature Range Nominal Operating Temperature Range Float Charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Charging Voltage Maximum AC Ripple (Charger) Self Discharge Accessories Terminal Terminal Hardware Initial Torque Terminal Hardware Annual Retorque 18 .2 No. "L" terminal with 0. 14. 5% RMS or 1.67 volts per cell at 77°F (25°C). rate to 1.5 in (1. SG = 1.4% RMS (4% P-P) Maximum current allowed = 6.1 sec 0.75 volts per cell @ 77°F (25°C). For higher temperatures the time interval will be shorter. Threaded brass inserts to accept 0. 134 Ah @ 20 hr.4 N-m) Operating Temperature Range Nominal Operating Temperature Range Float Charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Charging Voltage Maximum AC Ripple (Charger) Self Discharge Accessories Terminal Terminal Hardware Torque 19 . Specifications are subject to change without notification.84 100 lbs. rate to 1. Inter unit connectors.300 800 Amps 5100Amps @ 0. UPS12-475 – Specifications: Cells Per Unit Voltage Per Unit Weight Electrolyte Max. (With temperature compensation) +74°F (23°C) to +80°F (27°C) 13. 122 Ah @ 10 hr. Discharge Current Short Circuit Current Ohms Imped. racks and cabinet systems are available.HazardWatch NOTE: Batteries to be mounted with 0.80 volts per cell @ 20°C (68°F). -10°F (-23°C) to + 140°F (60°C).7 amperes RMS (C/20) Dynasty UPS batteries may be stored for up to 6 months at 77°F (25°C) and then a freshening charge is required.-lbs. 45 kg. -40°F (-40°C) to +160°F (71°C).8 VDC/unit Average at 77°F (25°C) 0.4 to 14. 60 Hz Ω Capacity 6 12. 110 in. Discharge.5% P-P of float charge voltage recommended for best results Maximum voltage allowed = 1.0023 Ohms 475 watts per cell at the 15-minute rate to 1. Charge.5 to 13.8 VDC/unit Average at 77°F (25°C) C/5 amperes (27amperes @ 100% depth of discharge) 14. (12. Absorbed H2S0.25 cm) spacing minimum and free air ventilation.25" (6mm) bolt. and open circuit or lead break detection is included.5mV. ±62.1.5°C 100.625mV. ±250mV Better than ±0. RTD °C Range (°F Range) Accuracy Pt1 -200 to 850°C (-328 to 1562°F) ±0.25°C Pt2 200 to 850°C (-328 to 1562°F) ±0.0°C S -50 to 1768°C (-58 to 3214°F) ±1. Ni (á = 1.25°C Ni -80 to 320°C (-112 to 608°F) ±0. 1. Pt. TC °C Range (°F Range) Accuracy J -210 to 760°C (-346 to 1400°F) ±0. ±125mV. 120. Cu (á = 1. ±1.6720).25°C Cu -200 to 260°C (-328 to 500°F) ±1. ±15.HazardWatch NOTE: Batteries to be mounted with 0.3911).0°C N -230 to 1300°C (-382 to 2372°F) ±0. Specifications subject to change without notification.0V.0°C E -200 to 1000°C (-328 to 1832°F) ±0.5 in. ±31. Pt2 (á = 1. spacing minimum and free air ventilation. Signal linearization.5°C K -200 to 1372°C (-328 to 2502°F) ±0. ±500mV. cold-junction compensation.00°C Alpha: Pt1 (á = 1. Ni. RTD Input RTD Input Ranges: 20 . user-configured.4272). or 10.7 Current Shunt and MV Transmitter 801A Alarms Specifications: DC Millivolt Input DC Millivolt/Voltage Input Ranges: Millivolt Accuracy: Thermocouple Input Thermocouple Input Ranges: Thermocouple type user configured.5°C T -260 to 400°C (-436 to 752°F) ±0.05% of input span.3850).25mV.5°C R -50 to 1768°C (-58 to 3214°F) ±1. Cu.5°C B 260 to 1820°C (500 to 3308°F) ±1. and alarm. 55mA @ 24V. linearization. EN61000-4-4. Units are fully programmable via the Windows 95/98/ME/2000/NT/XP IntelliPack Configuration Program. EN50082-1. status. cUL listed (USA.general product safety. Two independent SPDT electro-mechanical relays. 21 Electrical Fast Transient (EFT): Surge Withstanding Capability (SWC): Electrostatic Discharge (ESD): Radiated Emissions: Approvals: Configuration Software Configuration: Field Configuration: LED Indicators: Physical . EN50081-1 for Class B equipment. 1500V AC for 60 seconds or 250V AC continuous. EN50082-1. CE marked. EN61000-4-2. Contact material Silver Nickel (AgNi 90/10). 75mA @ 15V. EN61000-4-3. all types 25 ohms per lead Configurable for either upscale or downscale 0 to 500 ohms. ±0. EN50082-1.HazardWatch RTD Excitation Current: RTD Lead-Wire Compensation: RTD Break Detection: Resistance Input Resistance Input Range: Resistance Accuracy: Output Relay (801A-0100 models) Relays (801A-0200 models) Relay Ratings (CSA ratings) Expected Mechanical Life Environmental Ambient Temperature Operating: Storage: Relative Humidity: Power Requirements: Isolation: Radiated Field Immunity (RFI): Electromagnetic Field Immunity (EMI): 2. 25 to 70°C (-13 to 158°F) 40 to 85°C (-40 to 185°F) 5 to 95%. 3.05 ohms. Contact material Silver-Cadmium Oxide (AgCdO). Set point and deadband are configurable via pushbuttons and a standard calibrator. 3-way (input/output/power). 120/240V AC @ 5A. lead-wire compensation. 10 to 36V DC. One DPDT electro-mechanical relay. commutator motors.25% of input span from set point under the influence of electromagnetic fields from switching solenoids. 25V DC @ 5A. EN50082-1. UL3121 . Canada). EN61000-4-5. or 4-wire configurations supported. LEDs indicate power. Configuration downloads from PC through EIA232 serial port using Acromag 800CSIP kit. 20 million operations. UL. Module provides sensor excitation. and sensor break detection 1mA DC typical. No relay trips will occur beyond ±0. and drill motors. 26. To 10. Military grade FR-4 epoxy glass circuit board. generalpurpose NEMA Type 1 enclosure.3 to 1. 1. It is also listed by the Canadian Standards Association as certified.05W x 4.8 Battery Disconnect Switch and Polarized Connectors Connector Model SB ®50 Specifications: UL Current Rating (Amperes)*: UL Voltage Ratings (Volts): Contact Barrel Wire Size (AWG): (mm²): Maximum Wire Insulation Diameter (inches): (mm): AVG Contact Resistance*: Insulation Withstanding: Contact Retention Force (lbs): Life No load (Contact/Disconnect Cycles): Under Load (Hot Plug 250 cycles @ 120V): Avg. Connection/Disconnect –high detent: With lower extraction force: Operating Temperature Range °C**: Flammability Rating of Housing Material UL94 V: * UL Rated for 75°C rated wire or cable size ** Contact factory for higher temperature rated connector SB®.18 200 (micro-ohms) 2200 Test Voltage (Volts AC/DC) 50 22 .35D inches. Wire Range: AWG #14-22 (AWG #12 stranded only).6 polyamide thermoplastic UL94 V-2. UL and CSA Reference: This equipment is an Underwriters Laboratories Inc® recognized component.3 0.5D millimeters.45 Kg) packed.1.68H x 4.44 11. 1. 1 pound (0.000 50A 15(lbs) 10(lbs) 20° to 105° 0 50* 600* #6 to #16 13. color beige.7W x 118.9H x 110.HazardWatch Enclosure Case: Connectors (Removable terminal blocks): Printed Circuit Boards: Dimensions: Shipping Weight: Self-extinguishing NYLON type 6. It is also listed by the Canadian Standards Association as certified. To 10.6 136 (micro-ohms) 2200 Test Voltage (Volts AC/DC) 100 23 . Connection/Disconnect (lbs): Operating Temperature Range °C**: Flammability Rating of Housing Material: * UL Rated for 75°C rated wire or cable size ** Contact factory for higher temperature rated connector SB®.3 0. UL and CSA Reference: This equipment is an Underwriters Laboratories Inc® recognized component.3 to 13.000 60A 20 -20° to 105° UL94 V-0 120* 600* #2 to #6 33.HazardWatch Connector Model SB ®120 Specifications: UL Current Rating (Amperes)*: UL Voltage Ratings (Volts): Contact Barrel Wire Size (AWG): (mm²) : Maximum Wire Insulation Diameter (inches): (mm): AVG Contact Resistance*: Insulation Withstanding: Contact Retention Force (lbs): Life No load (Contact/Disconnect Cycles): Under Load (Hot Plug 250 cycles @ 120V): Avg.575 14. 50°C (32° .3 Fiber Optic Cable 1. 3 Axis.95% RHNC Up to 10000 feet (3 km) -10° to +65°C (14° .2 Coaxial Cable 1. 11ms 1. 3 Axis.87"D (447mm x 175mm x 428mm) 38 lbs (17.62"W x 6.8 GHz EIDE Hard Drive 24 . .75mm 0 .122°F) 10G.9"H x 16.24kg) Typical Options PIII 850MHz or P4 up to 2.HazardWatch 1.4.4 Central Station Equipment 1.1 UL 864 Computer Station 7890UL_B Specifications: Physical Size: Weight: Environmental Temperature: Shock: Vibration: Humidity: Altitude: Storage: Electrical Power: Voltage: Frequency: 300 Watt 115/230 Volts ±10% 50/60Hz 0 .5G. 10-150Hz.149°F) 17. 17". 19". 57-63Hz for 60Hz nominal Crest Factor up to 5 : 1 Waveform type Sinewave Output Connections (8) NEMA 5-15R Input Nominal input voltage 120V Input frequency 50/60 Hz +/. CD. 21" CRT 15".3 Hz (auto sensing) Input Connection Type NEMA 5-15P Cord Length 6 feet ( 1. SmartSlot .154 V Batteries & Runtime Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Replacement battery cartridge RBC7 RBC™ Quantity 1 Communications & Management Interface port DB-9 RS-232 .R/W Drive 40GB Tape Back Up PCI Sound Card 10/100 BTX Ethernet Card Quad Serial RS232/422/485 PCI 17".83 meters ) Input voltage range for main operations 82 .2 Central Station UPS APCSmart UPS Specifications: Technical Specifications Output Output power capacity 750 VA Output power capacity 600 watts Max Configurable Power 750 VA Max Configurable Power 600 watts Nominal output voltage 120V Output Voltage Distortion less than 5% at full load Output Frequency (sync to mains) 47-53Hz for 50Hz nominal . USB Available Smart Slot Interface Quantity 1 Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery: and Overload Indicators 25 .144 V Input voltage adjustable range for mains operation 75 .4. 19" LCD Resistive Touchscreen Serial or USB TS Controllers 101 Key PS/2 Compact Keyboard PS/2 Mouse with Scroll Bar 1.HazardWatch CD-ROM. 25°in (108°mm) 1. EN 55022 Class B. (0.00 cm ) Shipping Depth 23 inches ( 59. FCC Part 15 Class B.09 kg ) Shipping Weight 58 lbs.59 cm ) Maximum width 7 inches ( 17.94 cm ) Net weight 53 lbs.14°kg) 1.00 26 . EN 55024.3% IEEE surge let-through: zero clamping Response time: meets UL 1449 Physical Maximum height 9 inches ( 21.95 % Operating Elevation 0-10000 feet ( 0-3000 meters ) Storage Temperature -15 . ( 24.45kg) 2.86in (73mm) 6.02 cm ) Maximum depth 17 inches ( 43.30°lbs.50°in.74 cm ) Shipping Width 13 inches ( 32. DOC/Industry Canada.50in (165mm) 9.HazardWatch Audible alarm Alarm when on battery: distinctive low battery alarm : configurable delays Emergency Power Off (EPO) Optional Surge Protection and Filtering Surge energy rating 459 Joules Filtering Full time multi-pole noise filtering: 0.40 °C ( 32 .104 °F ) Operating Relative Humidity 0 .75°in (121°mm) 4. (38°mm) 4. CE.00lbs.00in (229mm) Black 672. ( 26.36 kg ) Shipping Height 15 inches ( 38. (. VCCI 0.06 cm ) Color Black Units per Pallet 24 Environmental Operating Environment 0 .45 °C ( 5 .113 °F ) Relay I/O SmartSlot Card Specifications: Physical: Net weight Maximum height Maximum Width: Maximum Depth Shipping Weight Shipping Height Shipping Width Shipping Depth Color Units per Pallet Environmental Operating Environment Storage Temperature Operating Relative Humidity Storage Relative Humidity Operating Elevation Storage Elevation Approvals 0-40°C (32-104°F) -14-65°C (5-149°F) 0-95% 0-95% 0-10000ft (0-3000m) 0-50000ft (0-15000m) C-tick. EN 55082. Code 128 (EAN 128). 18. Code 93. 1.76” W* x 6. logic-seeking or uni-directionalseeking 10 cpi. Courier. automatic fanfold positioning for zero tear off Push tractors (rear feed).4. LA36W: 13. POSTNET.47cm W* x 15.20 mm) dia. Orator..14” D (26. Multimode).4 Central Station Printer LA36W Specifications: Printing Technology Print Method Print Speed (cps) Print Head Bar Codes LQ: NLQ: Draft: Serial impact dot matrix Bi-directional.54cm) for rear panel flange 0° to 60° C (32° to 140° F) -40° to 85° C (-40° to 185° F) 0 to 95% RH. Print Line: LA36N: 8. 17. or 125 VDC. Interleaved 2 of 5. 1756 Chassis Installation 10. UPC-E. Matrix 2 of 5 Draft.0 in. Codabar b/n. Codabar c/*. OCR-A/B.36cm H x 4. -18dbm (Singlemode) -32dbm 1. Codabar a/t. 12 cpi 113 135 225 270 360 432 24-wire. Prestige. Dot Graphics (dpi): 120 to 360H x 180 to 360V Paper parking. EAN-13.3 Central Station Fiber Optic Converter PheonixDigital Specifications: Fiber Optic Cable Type: Mating Connector: Transmit Launch Power: Receive Sensitivity: Power Supply Plug-In Modules: Standalone Panelmount Modules: Environmental Operating Temperature: Storage Temperature: Relative Humidity: Dimensions 1771 Plug-In Modules: 1746 Plug-In Modules: 1756 Plug-In Modules: Standalone. and 20 cpi. Script.0079" (0. Codabar d/e. Roman Character Spacing: 10.. EAN-8. 0.38” H x 1. 15. non-condensing +5 VDC. 12.. Industrial 2 of 5.8 Amps (Typical 120/220 VAC.60cm D * Add 1. 10 Watts Multimode or Singlemode ST or SMA 15dbm (Typical. pull tractors (bottom 27 Fonts Printing Paper Handling Features: Paper Drive: ..4.6 in. Code 3 of 9.HazardWatch 1. UPC-A. 24 VDC. Panelmount: Modules: Single Slot. Sans Serif..00” (2. 1771 Chassis Installation Single Slot.1. MSI mod 101/10. LF Interval: 60 ms per line at 6 lpi. 1746 Chassis Installation Single Slot. From 600 to 38. (76-364 mm). (0.2/950.5 in.5 kg).5 in. 4-16. 41° to 104° F (5° to 38° C).014 in. (102-267mm).3 in. (102-420mm) 4 in.2 x 17 x 13in. LA36N . (133 x 570 x 330 mm). 4-16.5 kg).5 in.4 x 13in. or more (102mm). 50-60Hz.1 GM S4000C Combustible Gas Detector System Specifications 28 . CSA C22. or more (102mm) 4-10. and friction-feed platen for cut sheet. Paper Slew: 5. TUVEN 60950/08. Epson® ESC/P2 RS-232 Serial and bitronics parallel with DEC423 adapter. Class B of FCC Part 15B. EMKO-TSE (74-SEC) 207/94.6 ips DEC ANSI PPL2. 1 to 5-part top-glued cut sheets and envelopes 5 (original + 4 copies) Up to 0. LA36N: 16. CE marking One year return to depot 1. 4 in.5. (102-267 mm).35 mm). (133 x 434 x 330mm).5 in. Data Buffer Size: Up to 64K. 50-60Hz. LA36N: Averages 54 dB(A).5 GMI Field Devices 1.LA36W 4-10. 3-16. 10% to 90% relative 15. LA36W: Averages 56 dB(A) 100 to 120 VAC +/-10%. 200 to 230 VAC +6%-10%.1 x 22. Black: Up to 2 million characters UL 1950. LA36W: 18.7 lbs (8. 400 million impacts.HazardWatch Paper Dimensions: Continuous Forms Width: Continuous Forms Length: Cut Sheet Width: Cut Sheet Length: Paper Type: Number of Copies: Maximum Forms Thickness: Emulations Interfaces & Connectivity Baud Rate: Download Buffer: Physical Specifications Size Weight: Acoustics: Operating Environment Voltage: Temperature: Operating: Storage: Humidity: Reliability MTBF: Print Head Life: Ribbon Life: Regulatory Compliance Warranty feed).5 in. (102-420 mm) 3-14.5 lbs (7. IBM® ProPrinter XL24e.400 bps.000 hours @ 5% duty cycle. LA36W: 5. Up to 128K (HxWxD): LA36N: 5. (76-420 mm) 1 to 5-part side-glued or paper stapled fanfold continuous forms or label sheets with sprocket holes. 4° to 104° F (-15° to 60° C). 4 inches (161mm) 3. with 100% LEL methane applied 0-100% LEL Calibration. and setup options Dual redundant MODBUS RTU.HazardWatch Sensor Type: Accuracy: Zero Drift: Response Time: Measuring Ranges: Modes: Electrical Classification: Approvals: Continuous diffusion.0 inches (127mm)(center to center) 24 VDC nominal. fault odes. gas check. sensor error. 8A @ 250 VAC / 8A @ 30 VDC res. setup CSA/FM Class I. 4800. low temperature catalytic bead +3% LEL up to 50% LEL +5% LEL > 51% LEL Less than 5% of full scale per year T50<10 sec. CE Complies with ANSI/ISA-12.01-2000 performance requirements. (3x) SPDT .2mA 0-100% LEL 4-20mA Over-range 20-22mA Complies with EN50081-2. FM. 9600. EN50082-2 Three-digit digital display with gas concentration. non-condensing 6. Ex d IIB+H2. Class I.Warning. T6 ATEX EEx d IIB: T5 (Tamb = -40°C to +70°C) CSA.5 kg) 5. T90<30 sec.5mA Setup mode 1. Division 1. ATEX approved. Electronics: -40°F to 167°F (-40°C to 75°C) Standard Sensor: -65°F to 200°F (-55°C to 93°C) High Temp Sensor: -65°F to 400°F (-55°C to 200°C) -58°F to 158°F (-50°C to 85°C) 5% to 100% RH. Alarm & Fault 0-20mA (650 ohms max.1 inches (104mm) 5.5 lbs.4 inches (86mm) 4. load) Malfunction 0mA Gas Check 1.5mA Zero reading 4mA+0. calibration prompts. Zone 1. or 19200 BPS Calibration error.13. Warn and Alarm LED’s. Groups B. (2. max. C & D. 20 to 36 VDC 250mA max. open AO. low DC 29 Environmental Specifications Operating Temperature Range: Storage Temperature Range: Operating Humidity Range: Mechanical Specifications Length: Height: Width: Weight: Mounting Holes: Electrical Specifications Input Power: Relay Ratings: Analog Signal: RFI/EMI Protection: Status Indicators: RS-485 Output: Baud Rate: Faults Monitored: . suitable for linking up to 128 units or up to 247 units with repeaters 2400. EPROM. 0-50 ppm. C & D. Electronics -40°F to 167°F (-40°C to 75°C) Standard Sensor -40°F to 167°F (-40°C to 75°C) High Temp Sensor -40°F to 195°F (-40°C to 90°C) -58°F to 185°F (-50°C to 85°C) 5% to 100% RH. T6 (Tamb = -40°C to +60°C) ATEX EEx d IIB: T6 (Tamb = -40°C to +40°C) Two years CSA. T50<2 minutes (sintered) with full scale gas applied 0-20 ppm. adsorption type Metal Oxide Semiconductor (MOS) 3 to 5 years typical +2 ppm or 10% of the applied gas. (2740m) 1. switch error Cable Requirements: 3 wire shielded cable.HazardWatch supply.01. Zone 1 Ex d IIB+H2. ATEX.4 inches (161mm) 3. CE Marking. Part 1-1998 performance requirements. whichever is greater T50<1 minute (screen). setup Warranty: Approvals: Environmental Specifications Operating Temperature Range: Storage Temperature Range: Operating Humidity Range: Mechanical Specifications Length: Height: Width: Weight: Mounting Holes: Electrical Specifications Input Power: . Max. gas check. distance between S4000C and power source on the remote sensor @ 24 VDC nominal (20 ohm loop): 14 AWG .4 inches (86mm) 4. FM.5. non-condensing 6. EEPROM. Complies with ISA-92. 30 Continuous diffusion.5 lbs. Class I. gas check time exceeded. setup error. Groups B. 0-100 ppm Calibration. Division 1.0 inches (127mm) (center to center) 24 VDC nominal.2 GM S4000T H2S Gas Detector System Specifications Sensor Type: Sensor Life: Repeatability: Response Time: Measuring Ranges: Modes: Electrical Classification: CSA/FM Class I. 20 to 36 VDC 350mA max. distance for analog output (650 ohms max): 14 AWG .3000 ft.0. (2.9000 ft.5 kg) 5.1 inches (104mm) 5. (910m) Max. display and/or relays. ethane. propane. distance between S4000T and power source or remote sensor @ 24 VDC nominal (20 ohm loop): 14 AWG . EEPROM.9000 ft. duct mount junction box. 4800. gas check time exceeded.Warning. load) Malfunction 0mA Gas Check 1. Warn and Alarm LED’s. hexane. field mounted display. without splash guard Power-on self-test. (2740m) RFI/EMI Protection: Status Indicators: RS-485 Output: Baud Rate: Faults Monitored: Cable Requirements: 1. low DC supply. splash guard with optional test cell.2000 ft. EN50082-2 Three-digit digital display with gas concentration. and setup options Dual redundant MODBUS RTU.3 GM IR2100/IRFMD IR Gas Detector System Specifications Sensor Type: Measuring Range: Infrared Absorption Type 0 to 100% LEL 0 to 100% by Volume (methane only) Gases: Methane. junction box with optional zero switch. Max.5. Alarm & Fault 0-20mA (650 ohms max. calibration prompts. ethylene. sensor heater error. (optional) suitable for linking up to 128units or up to 247 units with repeaters 2400. (610m) Max.HazardWatch Relay Ratings: Analog Signal: 8A @ 250 VAC / 8A @ 30 VDC res. butane. & T90 < 10 sec. fault codes. multi31 Sensor Life: Accuracy: Zero Drift: Response Time: Modes: Accessories: . normal operation. EPROM. remote gassing guard. distance for analog output (650 ohms max):14 AWG . rain guard. switch error 3 wire shielded cable. calibration (zero only or complete calibration) Flow block. 9600. calibration error. Max (3x) SPDT . or 19200 BPS Open AO.5mA Zero reading 4mA+0.5mA Setup mode 1.2mA 0-100% scale 4-20mA Over-range 20-22mA Complies with EN50081-2. setup error. pentane & benzene (For other gases contact factory) Greater than 5 years + 3% LEL at < 50% LEL reading + 5% LEL at > 50% LEL reading < 2% per year (With 100% LEL Methane applied) T50 < 7 sec. 0 mA Zero Reading 4 mA +0. distance between IR2100 and power source @ 24 VDC nominal (10 ohm loop) 14 AWG (2.2 No. Hexane.2mA 0 to 100% LEL 4 to 20 mA (proportional) Over-range 20 to 22 mA Link up to 128 units. IP66. Groups B. optics failure/blockage.6 inches (269 mm) 3 lbs (1. EPROM and EEPROM checksum errors. 247 with repeaters Complies with EN50081-1.stainless steel 3/4" NPT Aluminum (stainless steel optional) 32 MODBUS Output: RFI/EMI Protection: Cable Requirements: Faults Monitored: Mechanical Specifications Diameter: Length: Weight: Mounting: Housing: .4 amp (nominal) 4-20 mA (600 ohms max.5 mA Dirty Optics 2. Type 4X Two years ATEX.HazardWatch Classification: Warranty: Approvals: Environmental Specifications Operating Temperature Range: channel controller Class I. low supply voltage 2. Benzene only: -40°F to +140°F (-40°C to +60°C) * For higher temperature range.0 mm2) – 1800 ft (550 m) Calibration errors. Benzene only*: -40°F to +140°F (-40°C to +60°C) Storage Temperature Range: -58°F to +167°F (-50°C to +75°C) Pentane. Division 1.87 inches (73 mm) 10. Hexane. consult factory Humidity: 5% to 100% RH. CE Marking and CSA 22.7 kg) .4 kg) – aluminum 6 Ibs (2. C & D EExd IIB+H2T5. 152-M1984 Performance Approved -40°F to +167°F (-40°C to +75°C) Pentane. non-condensing Electrical Specifications Input Power: 20-36 VDC 24 VDC @ 0.) Fault 0 mA Cal & Zero 1. EN50082-1 Max. HazardWatch 33 . 5 seconds and T90 ² 8 seconds when exposed to full scale gas concentration in ppm range ± 10% of last reading for each scale ± 10% over full scale for each scale No traditional calibration required. Groups C & D / EExd IIB T4 CSA-CUS.25 amp (Maximum) 24 VDC @ 1. Mounting arm 6. -40°F to +140°F (-40°C to +60°C) To 95% RH (Non-condensing) Per ISA/CSA C22. ATEX & GOST Test gas filters.4” Dia x 16.4” Dia x 12.5-6H Infrared absorption “Light Hydrocarbon Methane” unit 0 to 5000 ppm•meter and 0 to 5 LEL•meter 5 to 100 m (16 to 328 ft) T50 ² 4.5.3 Kg) Stainless Steel 11 lbs (5.1 Kg) Aluminum25 lbs (11.4 GM IR 5000 Open Path Gas Detector System Specifications Sensor Type: Ranges: Path Length: Response Time: Repeatability: Linearity: Calibration: Modes: Optional: Mechanical Housing Size: Source: Receiver Enclosure Material: Weight: Source: Receiver: Mount: Conduit Entries: Stainless Steel: Environmental Operating Temperature: Operating Humidity: Vibration: Weatherproof rating: Certification: Accessories: Electrical Operating Voltage: Power Consumption: Source: Receiver: Outputs: Analog Signals: 34 24 VDC nominal.0 Kg) Stainless Steel only (2) Aluminum: 3/4 NPT M20 x 1.2 No 152 and BS2011 Part 2.7 Kg) Stainless Steel 9 lbs (4. setup. IP66 Class 1.05 amp (Maximum) Two (2) analog signals and four (4) SPDT relays 600-ohm load max.1 standards Type 4X. alignment “Heavy Hydrocarbon Propane” unit 0 to 2000 ppm•meter and 0 to 1 LEL•meter detection ranges .7” Length (137mm Dia x 424mm Length) Copper-free Aluminum or 316 Stainless Steel 10 lbs (5 Kg) Aluminum 28 lbs (12. Div. Field background zero adjustment provided Test gas. 1.0” Length (163mm Dia x 305mm Length) 5.HazardWatch 1. 20 32 VDC range 24 VDC @ 1. < 3 sec @ 50 ft. LEL Warning. 250 VAC. For H2.High IR energy F5 .Close to minimum signal level F2 .2 microns (IR) 120° horizontal. Groups B.Low voltage F7 .2m) Distance for a 1 sq. Division 1and 2.Timing error F3 .7 to 3.Open current loop(s) 1.Large sudden change (blockage) 30 second Fault delay F6 . (FL3100) < 1 sec @ 50 ft.Low IR energy F4 .5000 ppm•meter 0-5 LEL•meter 20-22 mA Overrange Overrange Four (4) SPDT 5 amp @ 30 VDC res.50 feet (15. 135° vertical (FL3101) Approved performance specifications .5 mA Beam Block Beam Block or test gas or test gas 4-20 mA 0 . ft (0. contact factory. C & D 35 Typical Response Time: Minimum Sensor Response Time: Accessories: Classification: .35 microns (IR) Hydrogen FL3100: 2.HazardWatch Relays: Digital Display: Fault Codes: 0-5000 ppm•meter 0-5 LEL•meter 0 mA Malfunction Malfunction 1.Internal system failure F8 . 115° vertical (FL3100) 140° horizontal. test lamp Class I.092m2) Gasoline fire.5. mounting bracket.Failed to zero/Excessive negative drift due to background gas changes F9 .5 GM FL3100/3101UV/IR Flame Detector System Specifications Wave Lengths: Field of View: Sensitivity: 185 to 260 nm (UV) 4. air shield. max.FL3101 <100 ms Swivel elbow union. LEL Alarm and Fault Software Selectable: Latching/Non-Latching Warning and Alarm Energized/De-Energized Warning and Alarm Warning & Alarm level set-points Two digit. (FL3101) UV/IR FL3100 <500 ms UV. seven segment (auto range change) LED indication of scale displayed F1 . ppm Alarm. non condensing 20-36 VDC. 24 VDC @ 150mA max. ± 0. optics failure/blockage. or 10 seconds Warn & Alarm Relays: Latching/Non-Latching Energized/De-Energized MODBUS RTU.2mA 4mA.6w max. Optional – Dual MODBUS Complies with EN50081-2. ± 0.26kg) – Stainless Steel 3/4" NPT (2 ports) or surface mounting (ATEX) 2 x 3/4” NPT or 2 x m25 or 2 x m20 RS-485 Output RFI/EMI Protection: Cable Requirements: Status Indicator: Faults Monitored: Mechanical Specifications Housing: Diameter: Length: Weight: Mounting: Cable Entry: 36 .489 40°F to +185°F (40°C to +85°C) 58°F to +185°F (50°C to +85°C) 0% to 100% RH. 75%. ± 0. ATEX.HazardWatch Approvals: Environmental Specifications Operating Temperature Range: Storage Temperature Range: Operating Humidity Range: Electrical Specifications Input Power: Analog Signal: Fault Signal: COPM Fault: Ready Signal: IR Signal: UV Signal: WARN Signal: ALARM Signal: Baud Rate: Relay Contact Rating: Dip Switch Selectable Options: Class II. suitable for linking up to 128 units in series and up to 247 units with repeaters. 8. 4.914. 4800. fault and alarm indication EPROM and EEPROM checksum errors. FM.2mA 8mA. 8A @ 24 VDC resistive (North America) 8A @ 30 VDC resistive (Europe) Sensitivity: 100%.27kg) – Aluminum 16 lbs (7.) 4-20 mA (600 Ohms Max.5 inches (140 mm) 5 lbs (2. Class III. ± 0. ± 0.2mA 20mA.) 0mA 2mA. Type 4X. (3. Groups E. IP66 CSA.2mA 2400.2mA (FL3100 only) 16mA. 14 AWG . Patent Number 5. 50% Alarm Time Delay: 2. T5. distance between detector and power source @ 24 VDC nominal (20 ohm loop). ± 0. low supply voltage Aluminum (Stainless steel optional) 6 inches (152 mm) 5. EE x d IIC. CE Marking.3000 ft (930 m) Terminal Blocks -12-22 AWG LED with status. F & G. EN50082-2 Max. 9600 or 19200 BPS 8A 250 VAC.2mA (FL3100 only) 12mA. 0mA.) 0-20mA (600 ohms max. <500 ms Swivel elbow union. non condensing 4.) 0mA 2.2m) distance for a 1 sq. <3 seconds @ 50 ft. mounting bracket. C & D.2mA SPDT. IP66 FM.5 inches (140 mm) 5 lbs (2. Type 4X. Division 1and 2. ft (0. (3.0mA.26kg) – Stainless Steel 3/4” NPT (2 ports) 40°F to +167°F ( 40°C to +75°C) 40°F to +167°F ( 40°C to +75°C) 0% to 100% RH. 4. F & G. Class II.5.0mA. Sensitivity: 100%. 8.2mA 16. 75%. Class III. Groups B.27kg) – Aluminum 16 lbs (7. test lamp Class I. air shield. CSA. II2G EE xd IIC T5.0mA.2mA 4. 8A @ 24 VDC resistive max.092m2) gasoline fire. ± 0. or 10 seconds Warn & Alarm Relays: Latching/Non-Latching Energized/De-Energized MODBUS RTU. 8A @ 250 VAC. ± 0. ± 0.50 feet (15.150. ATEX & CE Marking Patent Number: 6.35 microns 110° maximum Approved performance specifications . Groups E.6w max.659 RS-485 Output: Option: .6 GM FL3102 DFIR Flame Detector System Specifications IR Center Wavelength: Field of View: Sensitivity: Typical Response Time: Minimum Sensor Response Time: Accessories: Classification: Approvals: Environmental Specifications Operating Temperature Range: Storage Temperature Range: Operating Humidity Range: Mechanical Specifications Housing: Diameter: Length: Weight: Mounting: Electrical Specifications Input Power: Analog Signal: Fault Signal: COPM Fault: Ready Signal: WARN Signal: ALARM Signal: Relay Contact Rating: Dip Switch Selectable Options: 20-36 VDC 24 VDC @ 150mA max.2mA 20. ± 0. 50% Alarm Time Delay: 2. suitable for linking up to 128 units or up to 247 units with repeaters Dual MODBUS 37 Aluminum (Stainless steel optional) 6 inches (152 mm) 5.HazardWatch 1. The smoke detector shall operate on a two-wire circuit and shall contain an alarm indicating LED. FM. distance between detector and power source @ 24 VDC nominal (20 ohm loop).1 Pyrotronics DI-3 Ionization Type Smoke Detector Engineer and Architect Specifications: • • • • • • • • • Adjustable Sensitivity Dual Chamber Sensitivity Test Points Simple Twist/Lock Assembly Optional Auxiliary Relay Screw-Clamp Terminals Alarm LED Listed. CSFM Approved The ionization smoke detector shall be a dual chamber plug-in unit. NYMEA. optics failure/blockage and low supply voltage 1. 4800./min. EN50082-2 Max. DI-B3 ONLY The detector shall be specifically designed for use in air ducts with air velocities between 500-4000 FPM when used with Cerberus Pyrotronics Series 3 air duct housings. Detectors which are not UL listed for the stated air velocity range shall not be accepted. 9600 or 19200 BPS Complies with EN50081-2. DI-A3 ONLY The detector shall be specifically designed for use in high air velocity applications of between 0 and 1200 ft. and shall be UL listed.6 Smoke and Thermal Fire Detection Equipment 1. DI-A3H or DI-B3H. Detectors not listed to UL 268A for the stated air velocity range shall not be accepted.12-22 AWG LED provides status and fault information EPROM and EEPROM checksum errors.6. The detector shall be available in a model that is acceptable for and UL listed for use in altitudes of 3000-8000 feet above sea level if desired models DI-3H.4500ft (1370 m) Terminal Blocks . Field adjustment* and monitoring of the detector sensitivity shall be possible without removal of the detector head from its base. which will illuminate to signal actuation of the detector.HazardWatch Baud Rate: RFI/EMI Protection: Cable Requirements: Status Indicator: Faults Monitored: 2400. 14 AWG . ULC Listed. which mounts to a twist/lock base. The measurement of detector sensitivity shall provide a 38 . ADB-3 audible or Series 3 air duct housing.HazardWatch discrete electrical value. or group of detectors. The detector assembly shall be a Cerberus Pyrotronics DI (insert number) with DB-3S mounting base. DI-3H only **DI-B3.** *DI-3. The detector. DI-B3H only Technical Specifications Current Requirements: Voltage Range: Operating Temperature: Humidity: Air Velocity: Normal 100uA (350uA peak surge upon application of power) Alarm 80mA 21 +3 VDC +32°F (0°C) to +100°F (38°C) per UL 0-93% Relative Humidity 0-300 ft.082300. Trouble or Alarm Indication Low-Profile Design Easy Twist-In Base Design Made in USA at ISO 9001 Facility Listed. FM Approved 39 ./min. Model DI-B3 (Requires air duct housing) Note: Consult factory for special application requirements. shall not be considered equal. Model DI-A3 500-4000 ft. The base assembly into which the detector is installed shall be of the twist/lock design with screw clamp terminals.6./min. The base shall utilize self-wiping contacts for reliability and shall accept other compatible plug-in detectors. or #18 AWG limited energy shielded cable without conduit. 1. ULC Listed. Optional auxiliary DPDT relays or remote alarm lamps shall be installed where indicated. CSFM NYMEA. For additional product information. A security lock shall be installed in those areas where tamper resistant installation is required as indicated on the drawings. if permitted by local codes. which do not provide an output signal proportional to smoke concentrations./min. Model DI-3 0-1200 ft. refer to Cerberus Pyrotronics DI-3 technical bulletin.2 Pyrotronics PE-11 Photoelectric Type Smoke Detector Engineer and Architect Specifications: • • • • • • • Advanced Field Cleanable Chamber Design Self Diagnostic Multi-Color LED for Normal. shall require a two wire circuit of #18 AWG thermoplastic fixture wire enclosed in conduit. Test methods. P/N 315. The detector shall be Pyrotronics Model PE-11 or Model PE-11T with a DB-11 surfacemounting base. which mounts to a twist/in base. The detector shall plug into its base and have a lamp to indicate the initiation of an alarm. and shall be UL listed. The detector shall allow for easy cleaning or replacement of screens and/or chamber components without affecting calibration. The detector shall be continually self-testing with visual operation indication and not require additional hardware or contact with the detector for testing purposes.HazardWatch The photoelectric smoke detector shall be a plug-in unit. When required. The base assembly into which the detector is installed shall be a twist/in design with screw clamp terminals. and alarm by flashing red. ULC Listed.FM and NYMEA Approved The thermal fire detector shall be a Pyrotronics Model DT-11 and shall be of the fixed temperature type.100mA peak Alarm . Inc and FM.3 Pyrotronics DT-11 Thermal Detector Engineer and Architect Specifications: • • • • • • Self Testing with Status Indicating Multi-Color LED Simple Twist /Lock Assembly Alarm Lock-in Remote Function Output Screw-clamp Terminals Listed. The plug-in thermal detector shall insert into the standard Series 11 base and shall be compatible with 40 .40mA 16 .39°C 93% non-condensing 1. CSFM.26. Actuation of this device shall lock the detector alarm circuit. The detector shall be listed by Underwriters Laboratories.6 VDC 0 . The detector or group of detectors shall require a two wire circuit of #18 AWG thermoplastic fixture wire enclosed in conduit.6. The smoke detector shall operate on a two-wire circuit and shall contain a multi-color LED indicator indicating the detector is operational by flashing green. or #18 AWG limited energy shielded cable without conduit. the smoke detector shall contain a 135°F fixed temperature self-restoring heat sensor. All wiring shall be approved for fire alarm use and in compliance with national and local codes. if permitted by local building codes. trouble by flashing amber. A security lock shall be installed in those areas where tamper resistant installation is required as indicated in the drawings. Technical Specifications Current Requirements: Voltage Range: Operating Temperature: Humidity: Normal . 4 Kidde Fenwal Detect-a-fire Thermal Detector Engineer and Architect Specifications: • • • • • • • • • Detect-A-Fire Models Explosion Proof Self-Restoring Detector Element Models Available in both Normally Open and Normally Closed Contacts in a Wide Range of Temperature Settings Factory Set and Hermetically Sealed in Stainless Steel Shell Listed and FM Approved as Fenwal Model Series 27120 and 27121 Manufactured for Siemens Cerberus Division by Fenwal The explosion proof thermal fire detector shall be a Detect-A-Fire explosion proof model.HazardWatch Pyrotronics ionization detectors. non-condensing No effect 135°F (57°C) 1. also for purchasing purposes referred to as Pyrotronics ( Model # ). flame detectors. The explosion proof detector shall have a self-restoring element and shall be factory set and hermetically sealed in stainless steel. Technical Specifications Environmental Temperature: Humidity: Air Pressure: Alarm Temperature: Electrical Voltage: Ripple: Supervisory Current: Alarm Current: 16-27 VDC 3V peak-to-peak 110µA max 33-50 mA 32°F (0°C) to 100°F (38°C) Up to 93% RH. These detectors shall be mounted in an approved explosion proof junction box. and shall be of the rate compensated type. The installing contractor shall install the detectors with #18 AWG thermoplastic wire with 300 volt insulation rating. Fenwal ( Model # ). The explosion proof detectors must be UL listed and FM approved 41 . and manual stations on the same circuit. housed in conduit or limited energy cable where permitted by local codes.6. photoelectric detectors. Americium 241. 0.6. Detector Type: Detection Principle: Chamber Configuration: Radioactive Isotope: Activity: Supply Wiring: Terminal Functions: Supply Voltage: Ripple Voltage: Quiescent Current: Switch-on Surge Current: Alarm Voltage: Normal Alarm Current: Alarm Indicator: Design Alarm Load: Holding Voltage: Holding Current: Products of combustion (smoke) detector.9 µCie.-8) (+7. 1.-8) (+/-10) (+/-10) (+/-10) (+/-15) (+/-15) (+/-20) (+/-25) Color Coding Yellow Yellow White White White Blue Red Red Green Orange Orange Orange Fenwal Model 27121-140 27121-160 27121-190 27121-210 27121-225 27121-275 27121-325 27121-360 27121-450 27121-500 27121-600 27121-725 Cerberus Pyrotronics Model DT-140EP DT-160EP DT-190EP DT-210EP DT-225EP DT-275EP DT-325EP DT-360EP DT-450EP DT-500EP DT-600EP DT-725EP Normally Closed Contact Fenwal Model 27120-140 27120-160 27120-190 27120-210 27120-225 27120-275 27120-325 27120-360 27120-450 Cerberus Pyrotronics Model * * * * * * * * * * Normally Closed Contact Detectors do not operate with any Cerberus Pyrotronics Control Panels. These Normally Closed Contact Detectors are offered for special applications only.3 k Becquerels.-8) (+7. polarity insensitive. Two wire monitored supply.Ionization Specifications are typical and given at 23°C and 50% relative humidity unless specified otherwise. Twin compensating chambers using one single sided ionizing radiation source.1Hz to 100kHz 30 to 45µA at 24V 80µA 6 to 28V 61mA at 28V 52mA at 24V 18mA at 10V Red Light Emitting Diode (LED) 450Ω in series with a 3V drop (LED open circuit) 6V (min) 10mA (min) 42 . Ionization chamber.-8) (+7.-8) (+7. 33.HazardWatch Model Cross-Reference Chart Normally Open Contact °F Setting 140 160 190 210 225 275 325 360 450 500 600 725 °F Tolerance (+7.5 Apollo Series 60 Ionization Type Smoke Detector Technical Data . L1 IN and L2: supply in connections (polarity insensitive) L1 OUT and L2: supply out connections (polarity insensitive) -R: remote indicator negative connection 17 to 28V DC 2V peak to peak maximum at 0. Detector in Base: 153 grams.0mA at 1V Factory set to ∆V of 1. (BS 5445 Part 7 1984) Maximum continuous operating temperature 60°C Minimum continuous operating temperature 0°C Minimum operating temperature (no condensation or icing) -20°C Automatic compensation by dual chambers to comply with EN 54 Part 7 1984. Tested to 90V/m from 27MHz to 1GHz.HazardWatch Minimum Voltage Required to Illuminate Indicator: Alarm Reset Voltage: Alarm Reset Time: Remote Output Characteristics: 12V 1V 1 second 900Ω in series with a 3V drop at 24V with 500Ω line impedance gives: 1mA at 9V 4.5mA at 5V 8. (BS 5445 Part 7 1984) across the operating temperature range 0% to 95% relative humidity Automatic compensation by dual chambers to maintain sensitivity up to a height of 2000m 2 m/s maximum (constant) 10 m/s maximum (transient) To EN 54 Part 7 1984 (BS 5445 Part 7 1984) To EN 54 Part 7 1984 (BS 5445 Part 7 1984) To EN 54 Part 7 1984 (BS 5445 Part 7 1984) IEC 801-2 (BS 6667 Part 2 1985) Severity Level 3.3V Nominal threshold Y value of 0. Tested to 12. Detector housing: White polycarbonate V-O rated to UL 94 Stainless steel Calibration: Sensitivity: Temperature Range: Temperature Compensation: Humidity: Atmospheric Pressure: Wind Speed: Vibration: Impact: Shock: Static: Radiated Emissions: Radiated Susceptibility: IP Rating: Dimensions: Weights: Materials: Terminals: 43 .000V positive and negative to the case and supply terminals from a 250pF capacitor BS 6527 Class B IEC 801 Part 3 Class 3 (10V/m). 43 Detector: 100mm x 42mm (diameter x height) Detector in Base: 100mm x 50mm (diameter x height) Detector: 102 grams.7 to EN54 Part 7 1984. 6 Apollo Series 60 Photoelectric Type Smoke Detector Technical Data – Optical Specifications are typical and given at 23°C and 50% relative humidity unless specified.0% light grey smoke obscuration per meter to EN 54 Part 7 1984.6. (BS 5445 Part 7 1984) -20°C to +60°C Negative temperature coefficient thermistor 0% to 95% relative humidity (no condensation) 44 Supply Voltage: Ripple Voltage: Quiescent Current: Switch-on Surge Current: Alarm Voltage: Normal Alarm Current: Alarm Indicator: Design Alarm Load: Holding Voltage: Holding Current: Minimum Voltage Required to Light Alarm Indicator: Alarm Reset Voltage: Alarm Reset Time: Remote Output Characteristics: Sensitivity: Temperature Range: Temperature Compensation: Humidity: .5mA at 5V 8.1Hz to 100kHz 30 to 45µA at 24V 90µA at 24V 6 to 28V 61mA at 28V 52mA at 24V 18mA at 10V Red Light Emitting Diode (LED) emitting red light 450Ω in series with a 3V drop (LED open circuit) 6V (min) 10mA (min) 12V 1V 1 second 900Ω in series with a 3V drop at 24V with 500Ω line impedance gives: 1mA at 9V 4. supply out connections (polarity insensitive) –R. Detector Type: Detection Principle: Chamber Configuration: Sensor: Emitter: Sampling Frequency: Confirmation Frequene: Number of Consecutive Sensed Alarm Signals Needed to Trigger Detector Alarm: Supply Wiring: Terminal Functions: Products of combustion (smoke) detector Photoelectric detection of light scattered in a forward direction by smoke particles Horizontal optical bench housing an infrared emitter and sensor arranged radially to detect forward scattered light Silicon PIN photo-diode GaAs Infrared light emitting diode Once every 10 seconds Once every 2 seconds 3 Two wire monitored supply. polarity insensitive L1 IN and L2: supply in connections (polarity insensitive) L1 OUT and L2. remote indicator negative connection 17 to 28V DC 2V peak to peak maximum at 0.0mA at 1V Nominal threshold of 3.HazardWatch 1. Tested to 12.000V positive and negative to the case and supply terminals from a 250pF capacitor BS 6527 Class B IEC 801 Part 3 Class 3 (10V/m). Tested to 90V/m from 27MHz to 1GHz 43 Detector: 100mm x 42mm (diameter x height) Detector in Base: 100mm x 50mm (diameter x height) Detector: 99 grams Detector in Base: 150 grams Detector housing: White polycarbonate V-O rated to UL 94 Stainless steel 45 .HazardWatch Wind Speed: Atmospheric Pressure: Vibration: Impact: Shock: Static: Radiated Emissions: Radiated Susceptibility: IP Rating: Dimensions: Weights: Materials: Terminals: Insensitive to wind Insensitive to atmospheric pressure To EN 54 Part 7 1984 (BS 5445 Part 7 1984) To EN 54 Part 7 1984 (BS 5445 Part 7 1984) To EN 54 Part 7 1984 (BS 5445 Part 7 1984) IEC 801-2 (BS 6667 Part 2 1985) Severity Level 3. -35°C to 72°C 1. IP55 enclosure Operating Temperature: Net Weight: Shipping Weight: Height: Width: Depth: Model 50GC 50GC 50GC 50GC Voltage 24VDC 24VAC 50/60Hz 120VAC 50/60Hz 230/240VAC 50/60Hz -31°F to 161°F.50".44".7 lbs. solid-state circuitry Available in 24VAC/DC.2 Federal Signal Model 300 GCX Selectone Horn Specifications: Designed for use in Hazardous locations Reliable.04 amps 0. Standby Current 0.07 amps 0.027 amps 0. 0.1 Federal Signal Model 50 GC Selectone Horn Specifications: Solid-state circuitry Available in 24VAC/24VDC. 87 mm Operating System 0.2 lbs. 14 mm 4.22 amps 0. 120VAC and 230/240VAC Built-in gain control Produces 64dB to 88dB @ 10' (74dB to 98dB @ 1m) UL and cUL Listed.095 amps 0. 114 mm 3.8 kg 2.025 amps 0. 1..0 kg 4.7. CSA Certified. CSFM Approved (California State Fire Marshal) Flush or surface mount NEMA 3R.7. 120VAC and 240VAC Built-in gain control allows volume adjustment from 86dBA to 110dBA at 10' (96dBA to 120dBA at 1m) UL-Listed CSA-Approved & CSFM Approved 46 .HazardWatch 1.02 amps Sys.013 amps Decibels @ 10’1M 88 98 88 98 88 98 88 98 1.7 Audible Devices 1..50". 203 mm 8. general alarm.55 amps 1. Model 300GCX 300GCX 300GCX 300GCX Voltage 24VDC 24VAC 50/60Hz 120VAC 50/60Hz 2240VAC 50/60Hz Operating System 0. evacuation and paging. Its sturdy construction consists of a die-cast aluminum amplifier housing and a spun aluminum speaker projector.3 Federal Signal Model 300X & 302X Selectone Horn Specifications: Explosion proof environments Available in 24VAC/DC.25". Like the 300GC. 2. The internal gain control allows tone output to be adjusted for 86dBA to a maximum of 110dBA at 10 feet (96dBA to 120dBA at 1m).but present potential dangers in the form of accidental ruptures or spillages. -35°C to 72° C 5.00". liquids.06 amps 0. constructed to IP55 Operating Temperature: Net Weight: Shipping Weight: Height: Width: Depth: -31°F to 161° F.7 lbs. This unit is UL(Underwriters Laboratories) listed and CSA (Canadian Standards Association) approved for Class I.. Class II.27 amps 0. Model 300GCX is recommended for use in Division 2 environments where flammable dusts. The SelecTone® model 300GCX is offered in 24VAC/DC.. 3 kg 12. Groups A.25".2 lbs. C and D. start and dismissal. The SelecTone model 300GCX can be used as a stand-alone.02 amps Decibels @ 10’1M 110 120 110 120 110 120 110 120 1.13 amps 0. Standby Current 0. 120VAC and 240VAC 47 . Model 300GCX is approved for use in Division 2 environments. Typical applications include emergency warning.25 amps 0.14 amps Sys. 210 mm Federal Signal’s SelecTone® Model 300GCX provides audible signals for warning in areas where hazardous materials are stored.HazardWatch NEMA Type 3R enclosure.7.03 amps 0. Groups F & G hazardous locations. The unit has a built-in volume control and a choice of many separate tones that can be heard clearly despite the many ambient noises in a plant.4 kg 6. 120VAC or 240VAC voltages. Division 2. Federal Signal’s model 300GCX allows for volume to be adjusted to overcome ambient noise levels. A conformal coating protects the unit’s PC board and components. which are both coated with a gray enamel finish. 311 mm 8. and gases are confined in closed containers. single signal audible warning device or as part of a plant-wide communication and paging system. This unit can be used as a single audible device or as part of a SelecTone system activated by automatic detection devices or a push-button command control. B. Division 2. constructed to IP44 These Federal Signal explosion proof horns are constructed for safety in hazardous environments. Model 41X is available in 24VDC while model 31X is available in 120VAC.10 amps 1.13 amps 0..& CSFM Approved NEMA Type 3R enclosure.02 amps 0.7.06 amps 0.13 amps 1. 375 mm 8.6 kg 14.13 amps 0.2 kg 19 lbs. On the 302X: from 90dB to 114dB at 10'. Models 31X and 41X Federal Signal models 31X and 41X are corrosion-resistant vibrating horns with stainless steel diaphragms.03 amps 0.75".27 amps 0. 48 . 100dB to 124dB at 1m UL-Listed. and features an internal volume control.HazardWatch Built-in gain control allows volume adjustment On the 300X: from 80dB to 104dB at 10' (90dB to 114dB at 1m). 375 mm Model 300X 300X 300X 300X 302X 302X Voltage 24VDC 24VAC 50/60Hz 120VAC 50/60Hz 2240VAC 50/60Hz 24VDC 24VAC 50/60Hz Operating System 0.50 amps 1.4 Federal Signal Model 41-X Selectone Horn Specifications: Designed for use in explosion proof atmospheres Resonating and vibrating horns Featuring corrosion-resistant cast aluminum housings Decibel ratings range from 100-107dB @ 10' (110-117dB @ 1m) Meets NEMA 4X specifications. 8. They have heavy-duty die cast aluminum housings which are tapped for 3/4” conduit.30 amps 0. Standby Current 0..03 amps Decibels @ 10’-1M 104 114 104 114 104 114 104 114 114 124 114 124 1. 225 mm 14.10 amps Sys. rated for IP44 Specifications for 300X: Net Weight: Shipping Weight: Height: Width: Depth: 18 lbs.75". CSA. 8.88". Division 1. Class II.7.5 lbs. 4. Both are CSA (Canadian Standards Association) approved. 4. laboratories. while model 56X is available in 125VDC...HazardWatch Both models are UL listed (Underwriters Laboratories) for Class I..5 MEDC XB3 Horn Zone 1. Class II.5 lbs.4 kg (41X) 9. UL Listed for USA and Canada 49 . Division 2.20 100 110 31X 240VAC 50/60Hz 0. Division 1. Model 55X is available in 120VAC. 7kg Model Voltage Amperage Decibels @ 10’1M 31X 120VAC 50/60Hz 0. 5.1 lbs. BASEEFA certified.1 kg (55X) 10. F & G and Class III.5 lbs. Groups C & D. Groups C & D.5 lbs. Class I. 4.. Class I. Groups E.8 kg Shipping Weight: (31X) 8. 4. Optional Exe terminal chamber. -35°C to 66°C Net Weight: (31X) 7. Operating Temperature: -31°F to 150°F. mines or grain elevators where the danger of explosion or fire exists.65 105 115 56X 125VDC 0.8 kg (56X) 10.7 kg (41X) 10. and G and Class III.3 lbs. Ex II 2GD. F.. Division 1. Model 55X is UL listed for Class I. 3.50 107 117 1. ATEX approved. Groups E..5 lbs. Division 1.. 3. EExde IIC T5. Both model 55X and 56X are CSA (Canadian Standards Association) approved.. Groups C & D. Division 2. Groups C & D.7 kg (55X) 12. Zone 2 and non-Ex use. These vibrating and resonating explosion-proof horns are designed for locations such as refineries.10 100 110 41X 24VDC 1.20 100 110 55X 120VAC 60Hz 0. Models 55X and 56X Federal Signal models 55X and 56X are resonating electric horns which produce sound by means of a diaphragm which resonates a column of air.0 lbs.7 kg (56X) 15. Their gray enamel finished housings are tapped for 3/4” conduit. BASEEFA Cert. No. AExd IIC T4. Listing No. End of line resistor option. – Ordinary locations: Audible-Signal Device. Certifications: CENELEC EN50014.HazardWatch −Hazardous locations: Class I. Tones comply with UK00A/PFEER guidelines. Up to 118dBA output. Any two tones may be switched via the external voltage supply. Tones may be programmed to customer specification. BAS00ATEX2098X. EExd IIC.c. Chinese (CQST) certified. −Ordinary locations: Audible-Signal Device. All GRP corrosion free flamepaths. and 48V d. version accepts any voltage between12V d. S8116. Div 2. Zones 1 and 2. EExde IIC. BAS00ATEX2097X. Groups A-D. No. Sounder/Beacon Combination Unit available. 19. Australian (SAA) certified. *Depending on version. BASEEFA Cert. Groups A-D. Class I.c. Zones 1 & 2. IP66 and IP67. 18.c. Refer to UL data sheet at rear of catalogue for 50 . *Certified temperature –55°C to +70°C. d. Class I Zones 1 & 2. UL Listed for USA and Canada – Hazardous locations: Class I Div 2. Listing No: E203310. AExd IIC T4. Integral volume control. GOST ‘R’ & ‘K’ certified. 27 tones. user selectable. c. 108dB(A) ± 3dB(A) (tone dependent). 110V a.c. 240V a. Stainless steel bracket with ratchet facility.). glass reinforced polyester. 48V d. Input Current (mA) 50 100 150 200 250 300 350 6.5kg for EExe).5mm2 (a. 51 Chinese Exd -20C to +55°C n/a *Output measured with 24V input voltage.0kg approx. Up to 254V a.c.).HazardWatch Material: Finish: Sound Output: Short Flare: Volume Control Nominal Output (dBA) 93 105 108 111 112 114 115 Weight: Ingress Protection: Fire Retardancy: Voltage: Certified Temperature EExd DB3 & DB3P DB3L & DB3LP -20°C to +70°C -55°C to +55°C V 12V d. dependent on model (+0. IP66 and IP67 GRP is fire retardant to ISO 1210 Up to 48V d. Tone set to 970Hz continuous. Swivel bracket & captive cover screws in stainless steel. 24V d. Chinese (CQST) Certification: Exd IIC T4.c. 254V a. Terminals: Earth Continuity: Mounting: EExde -20°C to +45°C -55°C to +70°C complete information. Long Flare: 115dB(A) ± 3dB(A) (tone dependent). GOST ‘R’ Certification: 1Exd IIC T4 & 1Exde IIC T4. natural black or epoxy paint coated to client’s colour requirements.c.c. GOST ‘K’ Certification: 1Exd IIC T4.c. 220V a.c. Body & horn in anti-static. Included on EExde version.c.c UL -55°C to +70°C n/a GOST ‘R’&‘K’ -20°C to +50°C -55°C to +55°C GOST ‘R’ Exde -20°C to +40°C -55°C to +55°C I 760mA 380mA 190mA 135mA 124mA 68mA 62mA 59mA 4 x 2. UV stable. 6 x 2. Current Consumption .c. Body and horn.5mm2 (d.c 120V a. or (ii) by a 3 wire common +ve system. Note: ATEX/UL Dual Listed version only up to 1/2" NPT available. switching between the two –ve lines. versions only.c. Remote 3 or 4 tone available – contact sales office for details. Note: Two-stage unit available in d. The DB3 may be combined with an MEDC beacon to create a combined audio/visual alarm.HazardWatch Labels: Cable Entries: Duty and tag labels optional. Tone Selection: Sounder/Beacon Unit: Two Stage Unit DB3P: 3/4 Tone Unit: 52 . Contact MEDC for price and specification Switchable between any two tones by either: (i) Reversing the polarity of the supply. Up to 2 x 20mm EExd 2 x 20mm EExe. Up to 2 x 1/2" NPT UL. 27 user selectable tones. HazardWatch 53 . MDL) 32°F to 120°F (0°C to 49°C) 32°F to 150°F (0°C to 66°C) -40°F to 158°F (-40°C to 70°C) -40°C to 66°C 5" x 5 5/8" x 215/16" 33/8" x 5 5/8" x 25/16" 5" x 5 5/8" x 15/16" 215/16" x 5 5/16" x 15/16" 7.6 Notifier Spectralert Horn Specifications: Horn shall be a System Sensor SpectrAlert Model capable of operating at 12 and 24 volts.2 oz. Horn shall be listed to UL 464 for fire protective signaling systems.8 oz. 24V: 20-30V 12V. 8. Input Terminals Dimensions Strobe and horn/strobe with universal plate: Strobe and horn/strobe with small footprint plate: Horn with universal mounting plate: Horn without mounting plate: Weight.7 Notifier Spectralert Horn 1.8 Crouse Hinds ESR Fire Alarm Bell Specifications: Application: ESR bell signals are used: for call signals. test functional integrity to -20% and +10% of manufacturer's stated ranges. 1. 4" x 4" x 1 1/2" or 2" x 4" x 1 7/8" standard boxes 12 to 18 AWG * These products should be operated within their rated voltage range. or in various other signaling applications in specific hazardous atmospheres such as in chemical plants.5-17V.7. oil and gas refineries. 20-30V (with Sync•Circuit module. grain processing industries and 54 . 24V.HazardWatch 1.7. however. All horn models shall operate on a coded power supply. 11-17V. UL does. strobe and horn/strobe: Mounting: Environment Indoor Operating Temperature: Weatherproof (horn and horn/strobes) Operating Temperature: (Outdoor strobe only): ULC Canadian Models: Electrical Voltages Operating voltage range* Operating voltage range* 12 or 24VDC and FWR unfiltered 12V: 10. alarms. The horn shall have two-tone options. horn only: Weight.7. bulk loading stations. Walk Test SpectrAlert horn/strobe and horn only work on “walk tests” with time durations of 4 seconds or greater. paint and varnish manufacturing plants. two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Standard Materials: Body .63 . with factory sealed wire leads in the interconnecting nipple and hub.53 .copper-free aluminum Gong .cover .body . bottom or either side (the striker must be located at the bottom for proper operation).41 135 . coal.75 .53 .62 .40 1.steel Standard Finishes: Feraloy iron alloy .natural Steel .HazardWatch grain elevators.67 .44 . as well as in certain metal.95 .gray matte Size Ranges: Hub .one 3/4" size Operating Current in Amperes at the Nominal Voltage For Bell Signals Amperes NOM Volts 12 24 48 115 230 All Vibrating 25 to 60 Hertz AC 1.189 . • The ac signal does not have arcing contacts.electrogalvanized and aluminum acrylic paint Aluminum . and mounted on a vertical flat surface with the striker at the bottom Features: • • • • • • • • • • • • • • • • The conduit hub contains an integral bushing.42 DC 1.65 . The body cover assembly permits the location of a hub at the top.092 55 All Single Stroke 50 to 60 Hertz ACDC 2. A vibrating or single stroke striker mechanism is furnished with 6 or 10 inch diameter gongs.Feraloy iron alloy Cover .69 1. The dc signal is provided with a GUAC junction box. combustible fiber processing or handling areas in conduit systems.copper-free aluminum Junction box .Feraloy iron alloy .086 .189 . Binding screw terminals are provided in ac signals for supply conductors. There are no external seals required except when used in Group B hazardous areas. 4 38.2 to 26.8 92 to 126. # ESR2675 GB ESR2674 GB ESR2673 GB ESR2672 GB ESR267388 ESR267288 ESR2662 67 ESR2663 67 48 115 38.2 to 26.2 19.6 to 13.2 to 26.6 to 13.4 to 52.5 230 12 24 48 'A DC 115 12 24 48 115 184 to 253 9. # Cat.4 38.2 to 26.HazardWatch Bell S i g n a l s Single Stroke Hammer (50 to 60 hertz) Cat.8 92 to 126.4 38.8 92 to 126. Bell Units Units# ESR2675ESR2674Group B Sound Pressure Levels at 10' Exceed (dB) 67 82 Sound Pressure Levels at 10' Exceed (dB) 64 64 Cat.4 to 52. # ESR2665 ESR2664 Vibrating Hammer (25 to 60 hertz) Standard Hub Size Supply Nom.2 19.5 9.5 6 '% a AC AC 230 184 to 253 ESR2671 GB ESR2615 GB ESR2614 GB 10 ESR2613 GB ESR2612 GB ESR2611 GB ESR2875 ESR2874 6 ESR2873 ESR2872 ESR2815 ESR2814 10 ESR267185 ESR261582 ESR261485 ESR261385 ESR261291 ESR261185 85 88 88 85 88 85 88 88 ESR2621 ESR2865 ESR2864 ESR2863 ESR2862 ESR2825 ESR2824 ESR2823 ESR2822 67 64 67 70 67 67 67 73 76 ESR2622 67 ESR2623 67 ESR2624 64 ESR2625 64 ESR2661 67 12 24 48 115 9.4 to 52. Volts 12 24 Voltage Range 9.5 ESR2813 ESR2812 56 .4 to 52.4 Dia.8 92 to 126.2 19.6 to 13.2 19.6 to 13. The strobe bells shall semi-flush mount to standard 4” square backboxes. Mounting options for surface. All bell and strobe bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of 12-22 AWG wire. Integral RFI suppression to minimize induced noise on the alarm lines. doors and other structures.9 Pyrotronics MBDC-6 Fire Alarm Bell Series MBDC Motor Bells & Strobe Bells • • • • • • • • • • • UL Listed for Fire Protective Service. Screw terminals permit fast in-out field wiring of 12-22 AWG wire. Both 6” and 10” shell sizes in 24 VDC models. Operate on filtered or unfiltered DC over a wide voltage range. The strobe shall be factory wired to operate in unison with the bell and shall produce 8000 peak candlepower at approximately one flash per second. Sound output at 10 feet shall be 92 dBA. 57 . Polarized for DC supervision of alarm lines. outdoor and concealed conduit installation. Built-in trimplate makes semi-flush mounting simpler and less expensive. Architects Specifications The alarm signals shall be Pyrotronics Series MBDC vibrating Motor Bells or approved equal. Operating voltage shall range from 19. They shall be UL Listed for Fire Protective Service. Low frequency aluminum shells for better audibility through walls. Strobe bells for combined audible and visual signaling have single input to save wiring time for 2-wire tandem operation of bell and strobe.HazardWatch 1. The bells shall incorporate a carbon brush motor and suppression to minimize RFI. semi-flush. or surface mounting to Pyrotronics indoor IBH-2 backbox or outdoor WBK-3 backbox. or surface mount using Pyrotronics SB backbox.7. Shells shall be aluminum in 6” or 10” diameter. They shall include a built-in trimplate for semi-flush mounting to standard 4” backboxes. Strobe bell models shall include an integral flashing strobe light with white polycarbonate lens and red “Fire” lettering.8 VDC. Finish on all models shall be textured red enamel. High Sound output with low current draw.2-28. HazardWatch 1.8 Visual Devices 1.8.1 Federal Signal Model 191 X Strobe Light Specifications: 24 to 250 VAC or VDC Six tempered glass dome colors Uses standard A-19 incandescent lamp (40W-100W) 3/4-inch pipe mount Dome Guard included UL Listed, CSA Certified for in door/outdoor use NEMA 4X, IP66 enclosure Lamp Style: Operating Voltage: Mount: Net Weight: Shipping Weight: Height: Diameter: Operating Temperature Chart Hazardous Environment Class I, Division 2 Max. Temperature*/ UL Temp. Code 350°C/T2 325°C/T2 260°C/T2B 215°C/T2D 200°C/T3 Dome Color Blue Red, Amber Clear All All Green, Lamp Wattage 100 (A-19) 100 (A-19) 100(A-19) 40(A-19) 40(A-19) Supply Wire Insulation Rating 125°C 125°C 125°C 85°C 85°C Incandescent A-19s (40W-100W) 24-250VAC/DC, 24-250VAC/DC 3/4" Pipe, 3/4" Pipe 3.3 lbs., 1.5 kg 4.2 lbs., 1.9 kg 8.75", 222.25 mm 5.5", 139.7 mm Class II, Div. 1 Groups E, F * at 40° ambient 1.8.2 Federal Signal Model 151 XST Strobe Light Specifications: Available in 12-24VDC, 120VAC and 240VAC Six dome colors 58 HazardWatch 10,000-hour high-intensity strobe 3/4-inch pipe mount Dome guard included UL Listed, CSA Certified for indoor/outdoor use NEMA 4X, IP66 enclosure Marine Rated Lamp Life*: Lamp Style: Operating Temperature Net Weight: Shipping Weight: Height: Diameter: * Optimal hours under ideal conditions. Model 151XST 151XST 151XST 1 10,000 hours, 10,000 hours Strobe, Strobe -31°F to 150°F, -35°C to 66°C 3.8 lbs., 1.7 kg 4.5 lbs., 2.0 kg 8.75", 222.25 mm 5.5", 139.7 mm ECP2 165 165 165 Voltage 12-24VDC 120VAC 50/60Hz 240VAC 50/60Hz Operating Current 1.3-0.60 amps 0.32 amps 0.16 amps Flash Rate/Minute 80 80 80 Candlepower Peak1 520,000 520,000 520,000 Mount ¾" Pipe ¾" Pipe ¾" Pipe Peak candlepower is the maximum light intensity generated by a flashing light during its light pulse ECP (Effective Candlepower) is the intensity that would appear to an observer if the light were burning steadily 2 1.8.3 Federal Signal Model 27XST Strobe Light Specifications: Available in 24VDC, 120VAC and 240VAC Six lens colors 10,000 hour, strobe tube 3/4-inch pendant mount standard Dome guard optional UL Listed, CSA Certified 59 HazardWatch NEMA 4X, IP66 enclosure Marine Rated Lamp Life*: Lamp Style: Net Weight: Shipping Weight: Height: Diameter: * Optimal hours under ideal conditions. Model Voltage Operating Current 1.25 amps 0.60 amps 0.30 amps Flash Rate/ Minute 80 80 80 Candlepower Peak1 2,000,000 2,000,000 2,000,000 ECP2 Mount 10,000 hours, 10,000 hours Strobe, Strobe 14 lbs., 6.4 kg 18.1 lbs., 8.2 kg 15.63", 397 mm 8.82", 224 mm 27XST 27XST 27XST 1 24VDC 120VAC 50/60Hz 240VAC 50/60Hz 850 850 850 ¾" Pendent ¾" Pendent ¾" Pendent Peak candlepower is the maximum light intensity generated by a flashing light during its light pulse ECP (Effective Candlepower) is the intensity that would appear to an observer if the light were burning steadily 2 1.8.4 Federal Signal Model 121 X Rotating Light Specifications: Available in 24VDC and 120VAC Five lens colors 3/4-inch pendant mount standard; other options available UL Listed, CSA Certified, Marine Rated Dome guard optional NEMA 4X, IP66 enclosure Lamp Style Lamp Life*: Operating Temp: Net Weight: Shipping Weight: Incandescent, Incandescent 800 Hours, 800 Hours -31°F to 150°F, -35°C to 66°C 14.75 lbs., 6.69 kg 18.9 lbs., 8.57 kg 60 800 ¾" Pendent ¾" Pendent 61 .82".33 amps 121X 121X 24VDC 120VAC 60Hz Flash Rate/ Minute 90 90 Candlepower Mount 2.63".05 amps 0.HazardWatch Height: Diameter: * Optimal hours under ideal conditions. 224 mm Model Voltage Operating Current 1. 397 mm 8.350 1. 15. UL Listed (SM87 HXBA only). Ex 92C 1389 (XB3 & LED3). Certification BASEEFA EExdIIC T6 (HXB & LED).2 Nos. IP66 and IP67. CSA version available only in stainless steel 62 . No.HazardWatch 1. CSA Certified. 9. Telephone or relay initiated. Optional EExe terminal chamber. GOST Certification: Contact MEDC for specification HXBS and LEDS – Grade 316 ANC4B Stainless Steel. 0. CSA Certification to C22. Div. Cert. Xenon or LED versions. Various lens colours. 1. Optional lens guard. 1 EExd. 137-M1981. Groups C + D (SM87 HXB only). Toughened Glass Epoxy paint finish as standard or to customer's specification Material: Lens: Finish: NOTE: Terminal Chamber available only in Stainless Steel. 0. (SM87 HXB only). Ex88B1232 (HXB & LED). GOST Certified. Div 1. BASEEFA Certified. Group D. Cert.5. 94-M91. EExde IIC T6 (XB3 & LED3). 0. Enclosure 3/4. No. CENELEC EN50014 and EN50018 and EN50019. Div. Class 1.8. Stainless steel or marine grade alloy.4. CENELEC approved. UL version is available only in marine grade alloy. Class 1. UL Listed for Class 1. 96406. HXBA & LEDA – LM25 TF Marine Grade Alloy.5 MEDC XB-3 Strobe Light Specifications: Zone 1 and Zone 2 use. 30M1986. EExde IICT4/T6. 49 Yellow 0.12 Amber 0.15 Blue 0.51 Green 0.86 The photometric data has been verified by BSI. 63 .HazardWatch For Colored Lenses Color Multiplying Factor Red 0. A report is available if required. HXBS & LEDS – 3. (With telephone initiate 8 x 2.HazardWatch LED Light Output Steady or Flashing (Customer selectable) Color Red Amber Green Blue Total LED Output (Candela) 192 64 17 64 Red.8kg each (approx). LED). LED3) 64 . UL Operating Temperature: Ingress Protection: Terminals: HXB: LED: Termination: HXB = –25°C to +40°C. IP66 & IP67. Labels: Entries: Duty & Tag Labels optional. XB3 = –20°C to +40°C. Yellow (not LED) or Clear (not LED). Models XB3 & LED3incorporate an Exe chamber for termination. Green. XB3&LED3–6offsuitableforupto6mm2 cable. LED/Lens Color: Weight: HXBA & LEDA: BASEEFA Operating Temperature: LED3: Versions are available certified up to +55°C maximum with a T4 rating. Telephone initiation or relay interface: Initiation by telephone ringing tone or low voltage control signals. Up to 4 x 20mm / 25mm ISO or 1/2" / 3/4" NPT. 4 off suitable for up to 2. LED = –20°C to +40°C. HXB = –55°C to +55°C. (HXB. Amber.5kg (approx).5mm2). –20°C to +40°C. 3 x 20mm or 25mm ISO (XB3. Models HXB & LED use a single Exd chamber.5mm2 cable. XB3 & LED3 – 4.). each (approx. Blue.5mm2 cable. 6 off suitable for up to 2. 2kg. Beacon/Sounder Combination Unit available. ATEX approved. Optional stainless steel backstrap. Optional telephone initiation. Filament version (20W) available†. Optional lens guard. Earth continuity option (model dependent). Chinese (CQST) certified. *Model dependent. Zones 1 & 2. Corrosion resistant GRP. Exd IIB T4. AExd IIB T4/T5. FB12 data sheet. Certified temperature –55°C to +70°C. FB11. Groups C & D. I P66 and IP67. 2 x M20 cable entries or 2 x 1/2" NPT*. 65 . Class I. FL12. BASEEFA certified. UL Listed for USA and Canada Hazardous locations: Class I.6 MEDC XB-11 Strobe Light Specifications: Zone 1 and Zone 2 use. Ordinary locations: Visual-Signal Device.HazardWatch 1. Fluorescent version (10W) available†. Australian (SAA) certified. T5 & T6. †See FL11. Ex II 2GD. Div 2. Various lens colours.8. 100°C (-55 t. 135°C (-55 t.amb +70°C) T4. Cert. −55°C to +55°C (T5). Chinese (CSQT) Certification: Exd IIB T5/T6.HazardWatch Certification: CENELEC EN50014 and EN50018. EExd IIB +40°C) T6. Material: Lens: Cover Screws + Backstrap: Finish: Body: Glass reinforced polyester (GRP) Glass Stainless steel 316 Natural black or painted to customer specification DC Voltage 24 XB11 Tube Energy (Joules) 5 Peak Current Consumption (mA) 320 Effective Intensity (Cd) 29 Peak Intensity (Cd) 22213 Power Consumption (Watts) 8 NOTE: The Cd figures are for a clear lens @ 1Hz flash rate For Colored Lenses Color Multiplying Factor Red 0. UL −55°C to +70°C (hazardous locations). –Ordinary locations: Visual-Signal Device.15 Blue 0. −55°C to +40°C (T6).86 The photometric data has been verified by BSI.amb UL Listed for USA and Canada to: –Hazardous locations: Class I. UL listing No.49 Yellow 0. BAS99 ATEX 2195X. S8128.5Kg.. EExd −55°C to +70°C (T4). Div 2 Groups C & D. Zones 1 & 2 AExd IIB T4/T5. Weight: Certified Temperature: 2.51 AC50/60 Hz 110 240 5 100 29 22213 11 5 60 29 22213 18 Green 0. 66 . Refer to UL Datasheet at rear of catalogue for complete information. UL Listing No: E187894. No.12 Amber 0.amb +55°C) T5. Class I. 85°C (-55 t.. A report is available if required. 569.7 Notifier Spectralert Strobe Specification: Walk test: SpectrAlert® horn/strobe and horn only work on “walk tests” with time durations of 4 seconds or greater. IP66 & IP67 GRP is fire retardant to ISO 1210 Optional for metal glands provided via a brass plate.288 cm) high x 2.593.25 mm² to 0. 5.625" (14. 6 x 2.938" (7.7 cm) wide x 5. 12V 8 – 17.8 oz. 3) maximum line impedance as required by the fire alarm control manufacturer.461 cm) deep.16 x 10.5 V 24V: 16 – 33 V. NOTE: ATEX/UL Dual Listed unit has up to 2 x ½" NPT entries only.938" (7. Input terminals: Dimensions. (Not available for UL version). strobe and horn/strobe with universal plate: Weight. 8. 1) 16-33 or 8-17. (250 g) Standard boxes 4" x 4" x 1.665. The beacon may be combined with an MEDC sounder to create a visual/audible alarm. 67 . 2 x ½" NPT UL.5 V.16 x 3. 95% as tested per UL 464.8.625" (14. strobe and horn/strobe: Mounting: Operating temperature 12 to 18 AWG (3. 6. ULC Canadian strobe model -40°C to 66°C. with small footprint plate: 3.08 x 10.51 mm²) 5" (12.5mm2 Initiation by telephone ringing tone Duty/Tag Label optional 2 x 20mm ISO EExd.763 cm).5 voltage range limit. 1.5" deep (10. 2) maximum number of 70 strobe lights when connecting the MDL Sync Module with a maximum line impedance of 4 ohms per loop and. Maximum humidity: Voltages: Operating voltage range*: U.S.573 cm) wide x 5.461 cm) deep. 24V: 17 – 33 V.81 cm) or 2" x 4" x 1.049. Contact MEDC for price and specification.914.288 cm) high x 2.446.HazardWatch Ingress Protection: Fire Retardancy: Earth Continuity: Terminals: Telephone initiation: Labels: Entries: Beacon/Sounder Unit: −55°C to +55°C (ordinary locations). Indoor: 32°F to 120°F (0°C to 49°C) Outdoor: Weatherproof Horn/Strobe 32°F to 150°F (0°C to 66°C) Strobe -40°F to 158°F (-40°C to 70°C).375" (8. Patent Numbers: *Note for Strobe: Do not exceed. 12 or 24 VDC and FWR unfiltered.16 x 4. With Sync-Circuit™ module MDL*: 12V: 9 – 17. 5.875" deep (5. 16 x 3. 12-volt rated devices shall have an operating voltage range of 9 – 17. Module shall be capable of multiple zone synchronization by daisy-chaining multiple modules together and resynchronizing each other along the chain. 24-volt rated devices shall have an operating voltage range of 17-33 volts. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.HazardWatch Engineering Specifications General — SpectrAlert® horns.763 cm) backbox using the universal mounting plate included with each SpectrAlert® product. The module shall be capable of mounting to a 4. The horn shall have two tone options. Synchronization Module — Module shall be a System Sensor Sync•Circuit™ model _________ Listed to UL 464 and shall be approved for fire protective service. while operating the strobes.125" (5.5" (10. unfiltered power supply. flashing at 1 Hz over the strobe’s entire operating voltage range. Also. Strobe — Strobe shall be a System Sensor SpectrAlert® model _________ Listed to UL 1971 and be approved for fire protective service. The horn on horn/strobe models shall operate on a coded or non-coded power supply (the strobe must be powered continuously). The strobe light shall consist of a xenon flash tube and associated lens/reflector system. over a single pair of wires.08 x 10. Strobes shall be powered independently of the sounder with the removal of factory-installed jumper wires. two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. 68 . Also. shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances. the module shall silence the horns on horn/strobe models. strobes and horn/strobes shall be capable of mounting to a standard 4" x 4" x 1. flashing at 1 Hz over the strobe’s entire operating voltage range.875" (5.16 x 4.398 cm) deep backbox and shall control two Style Y (Class B) or one Style Z (Class A) circuit. The module shall NOT operate on a coded power supply.688" (11.906 cm) square x 2. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances. The module shall synchronize SpectrAlert® strobes at 1 Hz and horns at temporal 3.16 x 10. SpectrAlert® products. SpectrAlert® products shall have an indoor operating temperature range of 32°F to 120°F (0°C to 49°C) and operate from a regulated DC or full-wave rectified. Horn/Strobe Combination — Horn/strobe shall be a System Sensor SpectrAlert® model _________ Listed to UL 1971 and UL 464 and shall be approved for fire protective service.5 volts. when used in conjunction with the accessory Sync•Circuit™ Module.81 cm) backbox or a single-gang 2" x 4" x 1. HazardWatch 69 .
Copyright © 2024 DOKUMEN.SITE Inc.