Haskel Liquid Pumps Booklet 7-1

March 25, 2018 | Author: kike82 | Category: Valve, Pump, Piston, Pneumatics, Gas Technologies


Comments



Description

Pressure on DemandPneumatic Driven Liquid Pumps High Pressure Haskel pneumatic driven liquid pumps are designed to provide a safe, reliable and economical, source of hydraulic pressure. This brochure introduces our pneumatic driven liquid pump range. Visit our website at www.haskel.com for more information or to locate a distributor. Why Use Haskel Pneumatic Driven Pumps? Our pumps offer many advantages over electrically driven pumps: • • • • • • • • Safe pneumatic operation – no heat, flame or spark risk Up to 100,000 psi (7000 bar) capability Infinitely variable cycling speed Stall feature at pre-determined pressure to hold that pressure without consuming power Problem-free stop/start applications Easily automated – many modification and control options Suitable for most liquids and liquefied gases Alternative gas drive options – sour gas, natural gas, boil off gases, nitrogen Applications include: • • • • • • • • • Pressure testing Work holding/power clamping Jacking/lifting Valve actuator control Hydraulic cylinder actuation Press safety overload devices Roller tensioning Metering Precision lubrication and spraying • Liquefied gas transfer 2 www.haskel.com • No need for air line lubrication – saves costs and prevents contamination • Robust, reliable, compact and easy to maintain proven design • Unbalanced cycling spool provides immediate response to pressure changes • Also available in standard, or custom built power pac configurations • Excellent worldwide service for spares and repairs • Can be manufactured to meet ATEX, CE and NACE 9 sq in (167 sq cm) Operation The pumps automatically reciprocate on a differential piston principle. a triple air head pump is identified with a last digit 3.Pressure and Flow on Demand This guide will help you to pre-select the pump ideally suited for your application. assuming adequate drive. actual ratio = 118:1 Nominal Ratio = 103:1** Nominal Ratio * (2) Indicates Double Drive Piston ** (3) Indicates Triple Drive Piston www. it will recycle as necessary in an effort to maintain maximum pressure.g. Similarly.9 sq in (167 sq cm) Area 25. the pump will cycle at maximum speed acting as a transfer pump to pressurize downstream. e. Thus.65 sq in (4 sq cm) Therefore.9 sq in (167 sq cm) Area 25.5 hp pumps by stacking air pistons without changing the hydraulic piston. The actual ratio is about 15% above nominal so that the pump continues to cycle when drive pressure equals nominal ratio.g. The pump design is sensitive to very small pressure drops due to the low frictional resistance of the large diameter drive piston and hydraulic piston seals.. a 900 ratio pump with three air heads is described as a 903. It will cycle at a slower rate as the fluid meets resistance until it stalls at maximum output pressure. Peak horsepower is at about 75% nominal ratio x drive pressure.2 sq in (163 sq cm) Area . The nominal ratio between piston sizes is indicated in the model coding and approximates to the maximum working pressure. These are approximate and peak at 100 psi (7 bar).com 3 .75 psi = 7500 psi (517 bar) hydraulic pressure.65 sq in (4 sq cm) Therefore. Single Drive Head Pump 25. 100:1 pump @ 100 psi air drive peaks at 100 x 100 = 10000 x 0. A large piston driven by relatively low pressure drive acts directly upon a smaller hydraulic piston. Initially. when drive pressure x drive piston area equals outlet (stall) pressure x driven hydraulic plunger area. Thus. pressure and volume. on a 1. e. Stall pressure is achieved when the outlet pressure rises and offers more resistance to the reciprocating differential piston assembly. Double air head pumps are identified by the last digit 2 in the pump model number. 0. a nominal 50:1 ratio pump with two air heads is described as a 52. If you have specific questions. as only one head is pressurized on the return stroke. Haskel multi-head pumps consume less air than competitive single head pumps of the same area. The piston assembly then stalls when the forces balance. actual ratio = 40:1 Nominal Ratio = 35:1 Double Air Head Pump Area 25.65 sq in (4 sq cm) Therefore.haskel. Double and Triple Air Head Pumps Performance can be extended for the 1. however. Output Horsepower Ratings The pumps are categorized on their horsepower ratings (see pages 6-7). When a pressure drop downstream occurs. we urge you to provide Haskel with the operational details of your application.e.5 hp pump additional heads can raise performance to 2 hp.2 sq in (163 sq cm) Area 25. i. actual ratio = 79:1 Nominal Ratio = 72:1* Triple Air Head Pump Area 25. We will recommend a model and any corresponding accessories.2 sq in (163 sq cm) Area . complete with “O” ring seal. Drive media forces the piston down on the compression stroke and raises it on the suction stroke (M series have a spring return). Hydraulic Seal 4 www. 2. 3. which causes the unbalanced spool to shift and reciprocate the piston. Hydraulic Seal/Check Valves This is one of the few wear parts. . 3. The pressure of hydraulic fluid on the down stroke closes the inlet check valve and acts against the spring to open the outlet check valve. On the down stroke. They are spring-loaded and have a very low cracking pressure. The piston is pre-lubricated during assembly and therefore no air line lubricator is necessary. first to the top of the drive piston. the diameter of which is constant throughout a given series of pumps. A distance piece can be incorporated between drive and hydraulic sections for complete contamination-free operation on most Haskel pumps. Hydraulic Check Valves Anatomy of a Pneumatic Driven Pump 1.com 4. its nominal ratio with the drive piston head. These check valves control the flow of liquid through the hydraulic section. allowing maximum opening on the induction stroke. which directs drive pressure. and then to the underside to reciprocate the piston (cycle). Fresh liquid is induced via the inlet check valve on the return stroke. It actuates via pilot valves at the top and the bottom of the stroke. Its function is to allow the hydraulic piston to reciprocate without passing fluid into the drive section. lightweight spool. unbalanced. Hydraulic Section/Check Valves The drive piston is linked and connected to the hydraulic plunger/piston in the hydraulic section. Outlet flow and pressure are determined by the area of the hydraulic piston head. Drive Cycling Valve 4. Drive Section 2. Drive Section The piston. Drive Cycling Valve This is a pilot-operated. its pressure and its temperature determine seal specification. liquid in the hydraulic section is forced under compression through the outlet check valve. fiberglass wound barrel.haskel. operates in an epoxy filled. and drive pressure.1. The liquid. 2. 2. Buna N All SS Stellite 15-5PH SS UHMWPE. 3. 5. Viton. Viton 8HSFD 1.5PH SS Urethane. 5 Nickel Plated Steel & SS 416 SS UHMWPE. PTFE. PTFE. Ryton Nickel Plated Steel & SS Stellite 15-5PH SS UHMWPE. PTFE. Rtyon Separation . Buna N DSXHW 1. 6 1. 2. Aluminum & SS 1. 2. 5. 2 DGF 1. 5A All SS & Bronze Hard chrome plated 440C SS PTFE. Buna N Separation .5PH SS PTFE. 6 DSHF GW 1 GSF 1. Ryton D14SFD-315 1. PTFE. 4. 6 DXHF 1. 3.Nickel Plated Steel & SS 440C SS UHMWPE. 2 . 4. 4. Ryton PTFE. Buena N. Viton.4PH SS PTFE. Rtyon Separation . 2. PTFE. 3. 2.All SS & Bronze Hard chrome plated 15. 3. 5 8DSFD 1.com 5 .5PH SS hard chrome plate optional UHMWPE.Nickel Plated Steel & SS 15.5PH SS UHMWPE. Ryton Separation . 5. Buna N Separation . PTFE. Ryton Separation. PTFE AW 1 Nickel Plated Steel & SS 440C SS Urethane. Viton. 2. 4. 5 DSF 1. Bronze & SS 15. 3. 2. PTFE All SS 440C SS UHMWPE. PTFE All SS & Bronze 15. Ryton DSTV 1.All SS & Bronze 15. Viton.5PH SS UHMWPE. PTFE. 3. 2. 6 Separation . Buna Nickel Plated Steel & SS 440C SS Urethane. 5 Separation.5PH SS UHMWPE.All SS & Bronze Separation.4PH SS PTFE. Buna N. 2 DSHF 1. Ryton www. Viton. 5A. 4. 5. 2 . 5 DGSF 1. PTFE. PTFE. 2 DF 1. PTFE. Viton. Viton SS. Ryton DFD 1.5PH SS Hard chrome plate optional Urethane. PTFE.All SS & Bronze 15. 6 Stainless Steel and Aluminum 303 Stainless Steel Viton. 4.5PH SS UHMWPE. PTFE.5. 5 Separation . 3.All SS & Bronze 15. PTFE All SS & Bronze Hard chrome plated 15.5PH SS Hard chrome plate optional UHMWPE. PTFE. Viton DHF DTN 1. Buna N DSXHF 1. 2.All SS 440C SS Hard chrome plated PTFE. Rtyon ASFD 1.All SS Stellite 15-5PH SS UHMWPE. 2 8DFD 1. 5.5 1. UHMWPE Neopreen. SS UHWMPE. 2. 5 8FD 1 8SFD 1. 5. Viton. Ryton 8DSTVD 8SFD2 1. Viton. Viton. Buna N. Buna N All SS Stellite 15-5PH SS* UHMWPE.33 hp MODEL M 1 MS 1.All SS 17. 2. 6 Separation. Ryton Separation. Buna N Aluminum. 2 All SS 15. 2. 6 Separation. 5. Buna UHMWPE. Viton. Aluminum Stellite 6B 300 Series SS PTFE. 6 ATV 1. Viton DSTV 1. Ryton DGSTV 1.5PH SS Hard chrome UHMWPE. UHMWPE Nickel Plated Steel.All SS Hard Chrome Plated 15. 5 Separation . Viton D14STD-315 1. Ryton Stainless Steel and Aluminum 303 Stainless Steel Viton. 3. 2. Ryton Separation. 300 Series and 17-4 Stainless Steel. 4. PTFE. Viton.5PH SS Viton. 2. 3.4PH SS Hard chrome plate optional UHMWPE. Viton. SS & Bronze Hard chrome plated 15. PTFE PTFE.All SS 17. PTFE.Nickel Plated Steel & SS 440C SS UHMWPE.haskel. 3. 5 Separation . Buna Separation . 2 DHF *Except -202 ratio is chrome plated 440 SS 6 hp Cad plated steel. Bronze & SS 15. Viton. 3. Ryton 4B-14 thru -37 1.All SS 440C SS Hard chrome plated UHMWPE.5 10 hp WETTED MATERIALS SERVICES (refer to pg. Viton Separation . 3.3 .5PH SS Hard chrome PTFE. 5 DSF 1. Ryton GWD 1 GSFD 1.5PH SS PTFE. 2 1. 6 Separation . 3. Viton. 3. 3.75hp . PTFE. 6 Separation. PTFE MCPV 1. 3. Buna. Viton 1. SS & Bronze Hard chrome plated 15. 2 29723 416 SS All SS 316 SS Urethane. 5. 2. Viton. 3. 3. Viton.All SS Stellite 15-5PH SS* UHMWPE. 2. Viton. 2. 6 All SS 15-5 PH Stainless Steel PTFE. Buna. 3. Buna N AW 1 ASF 1. 300 Series and 17-4 Stellite 6B PTFE. 6 Separation . 2. Buna.All SS & Bronze Hard chrome plated 15. 6 HF 1 HSF 1. 2. 2. 3. Buna N.All SS 15. 2 303 SS 440 C. Buna N.5PH SS UHMWPE. Viton. 4.5PH SS UHMWPE. Rtyon Nickel Plated Steel & SS Stellite 15-5PH SS* UHMWPE. Viton D14SFD-125 1. 6 PUMP SECTION MDSTV DSTV-1. 5 1. 2 Separation . Ryton Separation .5PH SS UHMWPE. 2 All SS & Bronze* 17. 2.5PH SS UHMWPE. 5A 6 All SS & Bronze Tungston Carbide Coated 15. 2 All SS 440C SS UHMWPE. 4. Viton Nickel Plated Steel. 2. Ryton 8DTVD 1. PTFE. PTFE. PTFE AFD 1 Nickel Plated Steel & SS 416 SS UHMWPE. PTFE DSTV-1.5PH SS UHMWPE. 2. 4. 6 DF 1.4PH SS UHMWPE.All SS 440C SS Hard Chrome Plated PTFE. 2 Aluminum Aluminum(Hard coated) UHWMPE. PTFE. 5 SS. 3. 3. Ryton Nickel Plated Steel & SS 15. Viton 1. 5. 3. Viton.Aluminum. PTFE 1. 5A All SS & Bronze Hard chrome plated 440C SS PTFE.5PH SS Hard chrome plate optional 17. Buna 4B-55 thru -150 1. PTFE.Nickel Plated Steel & SS Stellite 15-5PH SS* UHMWPE.5 hp . 2. 2 DGFD 1. 5.Nickel Plated Steel & SS Hard chrome plated 15. UHMWPE D14STD-125 1. Ryton All SS & Bronze* Hard chrome plated 15. 5. 6 HF 1 HSF 1. 4. Rtyon ASF 1. Buna.All SS Stellite 15-5PH SS Urethane. 3. 6 All SS & Bronze Tungston Carbide Coated 15. Viton. Ryton Nickel Plated Steel & SS 15.5PH SS + Dichronite UHMWPE.WETTED MATERIALS OF CONSTRUCTION AND SERVICES 1. 2. 2 1.All SS Stellite 15-5PH SS UHMWPE. Rtyon Separation . Viton.5PH SS UHMWPE. Viton. PTFE. 3. 5 DGSFD DGSTVD 8 hp NON METALLICS PLUNGERS MDTV DSFD 2 thru 3hp 1.6 All SS & Bronze* All SS & Bronze* 15-5 PH SS Hard chrome 15-5 PH SS Hard chrome Viton. PTFE.All SS 440OC SS Hard Chrome Plated UHMWPE. 5. 5. 4. 3. 6 1. PTFE. PTFE. PTFE. PTFE. PTFE. 3. 2 DTV 1. 17) 1. 5. 5. 5. 90 5.0 8.0 5.53 229 145 88 58 26 232 145 58 2660 1691 1026 669 296 1900 1182 476 43.088 0.7 9. MCPV MS Single Intermittent 5 7.0 2.01 4.5 17 29 40 69 115 173 230 1600 2400 4000 5700 9800 15000 15000 30000 110 165 276 393 676 1034 1034 2069 1600 2400 4000 5700 9800 16500 20000 33000 110 165 276 393 676 1138 1379 2276 8.2 369 6.9 19.41 0.5 22 37 58 75 112 192 217 210 M.0 0.5 bar Displacement/Cycle 625 900 1500 2600 4500 6500 8800 13500 15000 10000 20000 M.30 6.6 -125 -315 138 347 16000 36000 1103 2483 16000 36000 1103 2483 8.70 1.01 0.0 0.2 7.60 0.41 0.29 0.023 0. ASF.40 1.83 0.5 5104 3200 1215 810 486 348 201 123 81 81 41 32 20 83.75 hp 100 psi/7 bar 1.4 19.197 AFD-DFD-ASFD-DSFD -B60 69 6500 448 6500 448 1. DSF.3 8.9 11.34 0. DSF.71 1.9 6.20 0.7 3.3 8.6 19.8 -25 -40 -65 -100 -225 -55 -88 -224 27.7 0.5 -4 -B10 -B15 -25 -35 -60 -100 -150 -151 -225 -300 -450 1.9 0. MDTV 6 Ratio Dash Actual Area no.DGFD.90 20.0 2.36 0.DGSFD.5 4.1 19.0 0.0 22.7 4.14 0.6 bar Continuous -5 -7 -12 -21 -36 -50 -71 -110 -188 -188 -220 M. MS 125 psi/8.5 hp Single 150 psi/10.24 2.0 5.0 11.33 0.0 1.DSHF Triple psi 625 900 1500 2600 4500 6500 8800 13500 15000 10000 25000 AW.32 1.0 2.6 M.72 1.3 -8 -B22 -B32 -52 -72 -122 -202 -302 -452 -602 9.40 0.27 0.18 0.42 0.2 57. DGSTV 8SFD.DGSTVD 6 hp cu in 506 366 234 130 78 57 39 25 18 18 14 HF.05 2.18 0. ASF.5 1.67 0. DSXHF DXHF.34 ATV 8DSFD 8HSFD 8SFD2 (Double Air Drive Piston Models) 10 hp psi 0.2 3 hp ml 8.3 26.32 1.5 3.086 3.16 0.6 0.44 428 285 238 204 166 105 81 62 42 7.3 2.8 2.6 4.29 0.4 1823 1215 729 522 302 185 122 144 29.05 2.1 10.5 2.5 43.62 1.5 DSXHW -683 -903 -1373 780 1038 1575 30000 30000 30000 2069 2069 2069 70000 75000 100000 4828 5172 6897 0.40 3.0 31.67 0.0 1.4 -12 -35 -60 -100 14.4 44.0 5.7 4.0 2.6 11.DGSF.82 133 89 53.80 3.1 260 98 57 34 5009 1890 1103 662 82.DSHF GW.0 6.00 4.0 17.DSTV 2 hp 2 hp 2.16 0.68 -1.43 0.67 3.34 2.4 25 20 12 0.021 HF Double bar 43 62 103 179 310 448 607 931 1034 1034 1723 HF.8 8.0 2.3 1.5 3.0 13.4 9.18 0.5 17 29 40 69 115 173 173 260 345 533 160 690 1600 2400 4000 5700 9800 15000 15000 25000 30000 30000 45000 11 48 110 165 276 393 676 1034 1034 1724 2069 2069 3103 300 1200 1600 2400 4000 5700 9800 16500 20000 25000 37000 50000 45000 21 83 110 165 276 393 676 1138 1379 1724 2552 3448 3103 31.0 13.7 3.82 0.14 328 66. DTN.0 5.GSF.088 14.28 0. 29723 4B AW.8DSFD.89 3.6 38.12 0.52 1.DSTV 100 psi/7 bar Maximum Flow 43 62 103 179 310 448 607 931 1034 1034 1380 DSTV ATV.40 3.35 2.9 13.4 704 280 11.0 3.4 19.8 5.DGF. DF.0 ASFD -10 -15 -25 -35 -60 -100 -150 -202 11.5 0.6 52.10 5.6 4.0 6.0 11.9 13.8 40.3 1.36 7.22 0.6 9.023 0.0 513 328 66.22 DXHF.3 1. HSF.5 4.14 8. MCPV. DHF.06 0.1 10.6 19.40 0.56 14. Ratio D14STD.3 26.27 0.5 0.50 144. DHF. DTV 150 psi/10.GSFD.7 3.35 0.3 0.4 44.3 1. D14SFD .9 3.14 0.62 1.039 0.5 28. DSXHF GWD.6 2.0 11.70 1.84 3.9 3.1 31. MS 29723.2 23 34 57 80 138 230 346 520 690 850 3200 4800 5000 11000 15000 30000 30000 30000 30000 59 221 331 345 759 1034 2069 2069 2069 2069 1200 3200 4800 8000 11000 19000 33000 50000 70000 75000 83 221 331 552 759 1310 2276 3448 4828 5172 20 4.41 0.934 0.83 2.5 73 112 253 55 88 225 3575 6000 10000 10000 25000 5500 8800 25000 246 414 690 690 1724 379 607 1724 4000 6000 10000 10000 25000 7200 10000 25000 276 414 690 690 1724 497 690 1724 14. DF.64 0.13 0. MCPV.9 8.3 2.54 0. HSF.5 bar cu in/min l/min -14 -21 -25 -30 -37 -55 -75 -100 -150 16 24 29 34 42 63 86 114 171 1500 2300 2700 3200 3800 6000 7800 10600 15000 103 159 186 221 262 414 538 731 1034 1500 2300 2700 3200 3800 6000 7800 10600 15000 103 159 186 221 262 414 538 731 1034 0.0 18.33 hp 125 psi/8. MS.6 bar Single 0.60 0.17 0.3 69 115 1850 4375 7500 8000 128 302 517 552 4000 4375 7500 10000 276 302 517 690 15.27 0.00 3.Power Air Head Max Air Performance and Specification Overview Maximum Rated Output Pressure Pump Model Code Single 0.7 0.3 3200 1215 810 488 348 201 92 61 41 32 52.8DSTVD 8SFD 8 hp bar 13. MDSTV.13 1. 64 0.5 + 2 hp Extreme High Pressure pump series G 4.48 1.5 15.3 hp 325 cpm 0. These letters are explained in the chart below.15 200 400 700 1900 2000 4000 7000 10000 10000 15000 14 28 48 131 138 276 483 690 690 1034 1953 799 500 299 226 122 91.42 0.4 12. 2.5 3.9 32 16.30 0.9 3.9 39.42 3.9 16.33 0.9 9.2 1.09 0.4 800 2100 3000 5000 7500 12000 20000 30000 40000 50000 28 145 207 345 517 828 1379 2069 2759 3448 750 200 152 98 50 40.00 1.8 24.49 0.0 hp 50 cpm 10.28 2.2 1.7 5500 379 152 2.49 0.92 0.0 1.30 0.60 0.60 0.00 1.5 1.4 9.23 0.0 1000 1500 2500 3500 6000 10000 15000 20000 69 103 172 248 414 690 1034 1379 380 260 162 100 56 41 27 47 6.4 9.5” stroke 6 hp pump series B 4.9 5.80 1.6 4.1 9.5 + 2 hp High Pressure pump series -C Filter.23 0.15 60000 70000 90000 4138 4828 6207 4.75 hp 225 cpm 1.9 7.1 2.0 hp 80 cpm 6.66 0.6 4.0 3.64 0.26 0.67 0.25 0.2 0.98 0.5.1 2.08 0.60 1450 2000 2500 3000 3500 5000 7500 10000 15000 100 138 172 207 241 345 517 690 1034 61 120 61 62 82 66 37 26 7 1.78 1.22 4.8 6.5 0.0 hp 60 cpm 8.5 45.1 15.3 3.8 0.70 3.haskel.33 hp miniature pump series S Stainless steel hydraulic piston and body 29723 .19 3.28 2.00 2.7 39.75 hp pump series (bottom inlet only) A 2” stroke 1.00 1.43 0.9 29.82 0.16 0.55 4.27 5.36 11 13.6 tbd 19 8.2 16.14 0.9 5.4 32 13.7 0.09 2.2 15000 15000 16000 1034 1034 1103 19.0 hp 40 cpm www.77 3.24 415 600 1125 2000 3100 4500 6000 10000 10000 10000 15000 29 41 78 138 214 310 414 690 690 690 1034 249 160 100 48.6 81.08 2.6 0.31 0.65 tbd 0.0 and 2.9 14.5 500 750 1000 1500 3000 5000 7500 10000 34 52 69 1034 138 345 517 690 1520 1030 662 465 248 151 103 63 24.2 2500 4000 6000 10000 20000 4000 5000 18500 172 276 414 690 1379 276 345 1276 280 200 310 163 144 675 800 140 4.1 4.Typical Performance using 100 psi (7 bar) Air drive Outlet Pressure Outlet Flow Outlet Pressure Outlet Flow psi bar cu in/min l/min psi bar cu in/min l/min 225 300 700 1500 1700 2450 3000 7500 5000 5000 7500 15.6 0.8 20.93 0.66 1.5 14 14 12 4.6 1.5 + 2 hp pump series H 2” stroke 1.1 2.9 9.0 1.33 0. regulator with gauge and shut-off/speed control valve XH 2” stroke 1.28 3.1 13.5 3.7 59.28 1.11 50 100 400 750 1000 2000 3000 4000 7000 7000 7500 15000 36000 3 7 28 52 69 138 207 276 483 483 517 1034 2483 5000 1953 1000 598 403 350 152 100 59.4 20.2 15.6 29.15 tbd 0.2 20.77 200 1000 2000 2000 14 69 138 138 5004 1770 976 573 82 29 16 9.49 0.2 12.24 150 400 990 1600 2500 3600 6200 10000 15000 15000 24000 27000 45000 10 28 68 110 172 248 427 690 1034 1034 1655 1862 3103 1000 750 500 200 195 98 50 24.25 0.33 hp Chemical Pump D (Prefix) Pump incorporates a Distance Piece D (Suffix) Double Acting pump 4B 1” stroke .2 14.5” stroke 8 hp pump or booster series 14 4” stroke 10 hp pump series W Polyurethane U-cup dynamic seal F UHMWPE (Ultra-high Molecular Weight Polyethylene Dynamic Seal T Reinforced Teflon® dynamic seal V Viton® o-ring static seal -B Bottom inlet -CP Chemical Pump Guidelines for Continuous Duty Applications for Maximizing Seal Life Performance Pump Series Maximum Cycles per Minute 0. followed by a number indicating the practical working ratio of the drive area to the hydraulic plunger area.32 0.2 700 1000 1250 1500 1750 2000 2500 5000 7500 48 69 86 103 121 138 172 345 517 400 270 230 200 170 110 87 57 37 6.2 4.4 29.08 0.50 1.64 0.26 2.2 hp (Single and Double Drive Piston) 80 cpm 2.82 0.33 1.875” stroke .3 3.0 hp (Triple Drive Piston) 60 cpm 3.3 8.64 0.33 0.4 0.1 8.05 1000 69 348 5.1 0.2 12.6 3.67 2.4 1200 3500 5500 10000 83 241 379 690 1454 600 397 195 24 9.com 7 .5 21 48 103 117 169 207 517 345 345 517 500 350 200 90 70 tbd 40 20 18 18 15 8.3 Pump Selection Information All Haskel pumps are identified by letters coding the type of pump.44 0.98 0.2 34.3 8000 15000 552 1034 488 238 8.9 10.20 5.65 0.3 23. Pump Model Letter Coding M .5 2.2 1000 2000 3000 5000 10000 2500 4000 10000 69 138 207 345 690 172 276 690 2400 1420 880 555 270 1230 850 315 39.8 6.9 12000 30000 828 2069 195 79.7 2. MS -7 900 psi (62 bar) .8 ml) -12 1500 psi (103 bar) . .023 cu in (.039 cu in (0.2 cu in (3. Provides 1⁄8” NPT bleed signal port for single line remote control. 9 ratios.8 to 9 bar) Nominal Ratio Maximum Working Pressure Consult chart on page 6 for more information regarding continuous/intermittent pressures. water (plain or DI). Electric stroke counter provision. Only available on M and MS series. For weights and dimensions. Spring loaded shut. Optional Modifications Number Description Number Description -HP Hand pump attachment (with handle). Will hold full pump psi piloted from drive air. For field conversion of any .000 psi (688 bar) . Speed control valve.25 kW) M Series Pump Models Model Key Features • Choice of 6 models. Piped exhaust – standard. Provides ¼” NPT exhaust port. Cycle timer installed. Useful for metering applications. Vents are not threaded. Provides manual operation of pump for precision pressure control or use without air power Handle only.06 cu in (1. eliminates automatic cycling.haskel. M or MS series.3 ml) . ¼” NPT port. Vent hole 1/16 NPT M or MS series -21 through 188. -C air controls installed on pump. Stroke adjuster (includes 29697 above). Level II cleaning. Provides O-ring boss in aluminum block to enable mounting on side of tank below oil level.4 ml) . With handle. 51809 Normally open air operated release with relief valve. Piped exhaust (drive only). ¼” NPT port. Viton air drive. SAE outlet for M-pumps.0 ml) . Piped exhaust – sour gas.6 ml) . Without handle. MS. Some sacrifice of seal life at normal temperature. Provides highest release flow capacity. drawing 56643 for tank top mounting parts. Kits for converting existing units. Fits ¼” O. Ref. MDSTV -5 625 psi (43 bar) . ¼” NPT port. 29723 -110 -188 10. solvents.. SS trim for 1⁄3 hp drive ATEX Modification (Available on MS & 29723 but not M series). Extended life air drive.83 cu in (13. 3⁄8” SAE. Conversion kit.34 ml) For service codes. Piped exhaust – sour gas.4 ml) MCPV. Enables under tank top mounting and/or natural gas drive. Modification applies to M-21 through M-188 only. Noise reduction kit fitted. Palm or foot start/stop button drive. With hand pump (HP). Micro switch (BZE6-2RQ) mounted on upper cap trips with each cycle.33 HP pump.088 cu in (1. 26082 26220-2 26220-3 -V 26063-3 26064-3 26065-3 26065-3 plus 26064-3 28320 28590 28700-1 28926 29002 29697 51331 51788 51794 51794-2 51804 8 Manifold mount inlet port.33 hp (. MS -110 -188 13500 psi (931 bar) 15000 psi (1034 bar) . Provides improved fill on suction stroke pumping liquefied gases by utilizing the inlet pressure. ¼” NPT male port. Used to hold hydraulic jacks. Will release up to 11000 psi (using 100 psi air).D. liquefied gases • Drive pressure 25 to 125 psi (1.023 cu in (. Displacement per Cycle M. MCPV. Muffler (for use with piped exhaust modifications below).021 cu in (. Manual release with relief valve. Remote start/stop control. EPR seals for liquid section for 29723-XX ratio pumps. www. Ref. 6500 psi (448 bar) max. Relief is upstream of outlet check.36 cu in (5.4 ml) MS -220 25000 psi (1723 bar) . External air pilot. 27 possible combinations • Flows to 2 gpm (7. 29723 -21 -36 -50 -71 2600 psi (179 bar) 4500 psi (310 bar) 6500 psi (448 bar) 8800 psi (607 bar) .6 ml) M. Without hand pump (HP).9 ml) M. new style exhaust muffler. Provides connection ports for drive and pilot exhausts. Dead Man valve. No return spring. High pressure outlet port.0 ml) M. Tank return is 1⁄8” NPT in pump body. Provides high pressure needle valve with internal adjustable safety relief downstream of pump outlet checks. Solid air cap. Not available in 188:1 ratio.12 cu in (2. Vents are not threaded.6 cu in (9. Low temperature drive. Enables operation down to 5°F.039 cu in (0. see page 17. Provides 1⁄8” NPT port for external air to pilot for remote start/stop.5 l/min) • Choice of wetted materials • Single air head • Pressures to 25. Normally closed air operated release with relief valve.6 ml) . For M and MS pumps only.000 psi (1724 bar) • All Hydraulic fluids. Single stroke from remote air pulse. Combination air regulator/filter with gauge. see page 18. EPR Seals for M and MS series for Liquid Section. Knurled knob with vertical scale on pump cap. 1⁄8” NPT signal port. drawing 56643 for tank top mounting parts. high pressure threaded and coned tube. Air OP release valve. Useful for metering applications. mild chemicals.com 51809-1 51810 51811 52340 52950 53175 53304 53784 53935 54179 57905 59888 80103 80348 81499 82367 82500 85630 86337 Safety relief valve. One stroke per air pulse signal. ¼” NPT port. see page 18. Single acting drive.17 cu in (2.000 psi (1034 bar) • Drive pressure 3 psi to 100 psi (. For weights and dimensions.8 ml) -25 2700 psi (186 bar) .56 kW) Pump Models Maximum Working Pressure Model Nominal Ratio 4B -14 1500 psi (103 bar) .5 cu in (8. 57639 57960 58475 59354 www. ATEX modification.com 9 . 1⁄4” SAE..haskel. Provides 1⁄8” NPT port for external air to pilot for remote start/ stop operation.1 ml) -37 3800 psi (262 bar) .4 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures.2 ml) -30 3200 psi (221 bar) . Recommend for use with water.9 cu in (14. 6500 psi (448 bar) max. Noise reduction kit fitted.7 ml) -55 6000 psi (414 bar) . Extended life air drive.6 mil) -75 7800 psi (538 bar) .13 cu in (2.2 to 7 bar) • Single air head • Flows to 1. Low drive air pressure.2 bar).8 ml) -100 10600 psi (731 bar) . see page 17.8 ml) -21 2300 psi (159 bar) . Not recommended for long stall periods.43 cu in (7. Key Features • One model available in 9 ratios • Choice of wetted materials • Output pressures to 15. Viton air drive. Changes the “F” seal to a “W” seal. Extreme cycling service. 59888 80637 81575 82104 82500 86337 Cycle timer installed.35 cu in (5.6 cu in (9. Displacement per Cycle For service codes. SAE outlet fitting for ratio 37 to 100.7 l/min) Optional Modifications Number Description Number Description -C 56564 56594 Air drive controls.75 hp (.5 gpm (5.22 cu in (3.088 cu in (1.1 ml) -150 15000 psi (1034 bar) . External air pilot. Used for pumping liquefied gases under pressure. Allows user to regulate drive air to as low as 3 psi (. 1⁄8” NPT port on drive for recycle valve connection. 0 l/min) • Choice of wetted materials • Single air head • Drive pressure 3 to 150 ps (. Includes 28881 modification. chemical. www.7 cu in (44.6 ml) 1.28 cu in (4. 29376 Three-way cycling spool. DSF. 13 ratios. For 1. Severe Arctic low temperature service.18 cu in (3. With back pressure balance piston.4 cu in (6. Allows remote start/stop of pump. 17860 Electrical stroke counter provision. 51056 Exhaust/pilot vent combination.3 ml) 1.A. 54935 SS trim for 5/3 air drive. -CO Air controls with recycle button.9 cu in (513. ½” female for 4:1 ratio series pumps (ATV-4 or DTV-4). For F or TV series pumps. 54885 Rotate pump body 90° from standard. or AWD series pumps).5:1 ratio. ASFD or DSFD.5 hp and 2 hp pumps only. 81453-2 1⁄4 HP inlet fitting. 55630 Stainless steel (AISI-316) distance piece. DF.E.2 cu in (19 ml) .5 ml) . ½” NPT.5 hp and 2 hp pumps. Applies to distance piece pumps only. Not recommended for long stall periods. DFD. Except 1. single acting.5:1 ratio.0 ml) .2 to 10 bar) (1) These series are “Lift” pumps and maximum outlet pressure is (air drive x pump ratio) + inlet pressure (2) DTV has poppet checks For service codes. 28003 Test port. 82460 HNBR seals in air drive section.5 hp to 2 hp pumps.09 cu in (1.14 cu in (2. shut-off). -CP Air controls with precision regulator. see page 17. For 1. DSF.0 ml) AW.4 ml) 2.5 hp and 2 hp single acting pumps. 51331 -CPO Air controls with precision regulator and recycle button. -60. 15 pump minimum. 27964 Interconnecting inlet-outlet tubing. -B15. -W Additional upper foot bracket.5 hp and 2 hp pumps (not applicable to high output.C. 1. except 1. For special sealing in air drive for operating temperatures from as low as -20°F up to normal +120°F. DTV(1) (2) DTN(1) Key Features • Choice of 11 models. -4 1200 psi (83 bar) 20. ½” NPT. -225.haskel. “BR” on -B10. ASF. DF.5 hp to 2. 82958 Medium pressure outlet port.7 ml) . 50 possible combinations • Output pressures to 50. 59353 Noise reduction kit fitted. 16831 10 Bottom Inlet (designate “B” before ratio dash number. 28881 Air pilot modification. Low temperature modification. -100.000 psi (3448 bar) • Flows to 22 gpm (83. except high output models. 55516 Polyurethane (“W”) seal. 28000 Threaded vent (or purge) ports on standard distance piece. installed (6 digit). -300. 1⁄8” NPT. ASF. Includes BZE6-2RQ microswitch. specifications. 55305 Tube ports. 25721 Mechanical stroke counter.2 hp distance piece pumps only. 51050 Extreme service cycling modification.com .12 kW) Pump Models Maximum Working Pressure Model Nominal Ratio Displacement per Cycle DSTV(1) -1. ½” NPT. -35. 86337 Extended life air drive. -150.0 ml) AW. 51345 Sour gas drive provision to N. For operating at air pressures as low as 3 to 4 psi (. DSTV -B10 -B15 -25 -35 -60 1600 psi (110 bar) 2400 psi (165 bar) 4000 psi (276 bar) 5700 psi (393 bar) 9800 psi (676 bar) 4 cu in (66. see page 20.0 ml) ATV.5 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures. For 1.7 cu in (11 ml) ATV -8 850 psi (59 bar) 20 cu in (328.0 cu in (328. -B22 and -B32) 1.3 bar). HSF. 16834 Exhaust adapter.5 160 psi (11 bar) 31. 53925 16821 Low air pressure control feature. 81453 3⁄8 HP outlet fitting. DSTV -100 -150 16500 psi (1138 bar) 20000 psi (1375 bar) . gauge.28 cu in (4.2 hp.6 cu in (26. 2. For 1. -25. single air head and double air head. Not available on AFD. for use with CO2 29702 Single stroke modification. regulator. ½” NPT.2 to . EPR (Ethylene propylene) static seals in wetted section.1. Optional Modifications Number Description Number Description -C Air controls (filter.5 hp (1. -10 ratio or higher. DSHF -151 -225 -300 25000 psi (1724 bar) 37000 psi (2551 bar) 50000 psi (3448 bar) .3 ml) HF -450 45000 psi (3403 bar) . -151. For weights and dimensions.5 hp to 2 hp pumps.5 ml) HF. 29806 Double distance piece. Provides access port in pump’s body between inlet and outlet check valves for 1. -450 ratios. 82500 ATEX modification (not available on AW or DSXHW pumps). 5⁄8” SAE inlet and outlet. -B 52788 Viton seals air drive. Optional Pump Inlets for Tank Mounting To specify ratios -10. Drive inlet also includes a ½” NPT male x ½” NPSM female (straight pipe thread) swivel adapter (connecting male nipple should include 30° inside bevel for proper fit).5 hp (1. Distance Piece (Separation) Pumps with prefix “D” in the model number have aluminum distance piece between the air drive and pump section (except DSTV-1.1. low ratio pumps are capable of pressures to 1200 psi (82 bar) and flow rates of up to 22 gpm (83 l/min).12 kW) High Output Flow Pumps Available in a choice of 4 models.g. -15. Inlet on the bottom and externally threaded 1” NPT male Internally threaded ½” NPT female Drive inlet and exhaust are ½” NPT female. -22 or -32.haskel.]Ê add “BR” between˜Ê the model numberr and the ratio.5 has a maximum air drive of 150 psi (10 bar) and is capable of pressures up to 160 psi (11 bar). DTN-4 and DTV-4 work on a maximum air drive of 150 psi (10 bar) and have a maximum intermittent pressure rating of 1200 psi (83 bar). Mounting Brackets All series mounting brackets have 7/16” holes (slots) for 3/8” bolts. These are “lift” pumps whereby the outlet pressure equals the air drive x the pump ratio plus the inlet pressure. Horizontal mounting is recommended for non-exchange of contaminants.5). AW-B25. Specify modification number 28000. The model ATV. www. Vent holes can be threaded ½” NPT female at extra cost.g. A noise reduction modification is available for applications where noise level is an issue. e. AW-BR10. Upper mounting brackets are not furnished as standard on single air head non-distance piece units. these high output.com 11 . Dimensional Data Mounting Brackets Model DSTV-1. Inlet externally threaded 1 ¼” NPT male Internally threadedd 1” NPT female To specify ratios -25 through -903. add “B” between the model number and the ratio. e. haskel.8 cu in (13. DFD. see page 20.2 hp Key Features • Choice of 16 models. not only to simplify priming but to reduce fatigue stresses. 2.49 & 1.0 ml) DSXHF -903 75000 psi (5171 bar) .4 ml) . DF. HSF. 1600 psi (110 bar) 2400 psi (165 bar) 4000 psi (276 bar) 5700 psi (393 bar) 9800 psi (676 bar) 16500 psi (1138 bar) 20000 psi (1379 bar) 33000 psi (2275 bar) For service codes.24 kW) Pump Models Model ASFD Nominal Ratio 10 15 25 35 60 100 150 202 Maximum Working Pressure Consult chart on page 6 for more information regarding continuous/intermittent pressures.2 cu in (19 ml) . The higher the supercharge. see page 21. see page 17. 46 possible combinations Maximum Working Pressure Nominal Ratio Model For service codes. Also install a relief valve to protect the lower pressure pump from potential back pressure.3 ml) DSXHW -1373 100000 psi (6895 bar) .5 ml) DXHF. Supercharging of the -1373 model is recommended. -202 33000 psi (2275 bar) .09 cu in (1.64 kW) Pump Models 2 hp • Output pressures to 100000 psi (7000 bar) • Flows to 5 gpm (15 l/min) Consult chart on page 6 for more information regarding continuous/intermittent pressures.7 ml) DHF.2 to 10 bar) Displacement per Cycle 8. Displacement per Cycle AW.4 ml) 2.1 cu in (132.0 ml) DSXHF -602 75000 psi (5171 bar) .4 cu in (88.14 cu in (2. 3 hp (2. -452 70000 psi (4827 bar) . Key Features • One model available in 8 ratios • Output pressures to 33000 psi (2275 bar) • Flow rates to 8 gpm (30 l/min) 12 www.3 cu in (38 ml) 1.14 cu in (2.3 cu in (53.3 cu in (22 ml) • Choice of wetted materials • Double and triple air heads • Drive pressure 3 to 100 psi (.6 cu in (9 ml) .18 cu in (3.8 ml) 5. see page 17.28 cu in (4.7 cu in (11 ml) HF. -683 70000 psi (4827 bar) . 13 ratios.3 ml) 1.3 ml) DXHF.4 ml) .2 ml) 2.2 hp (1.2 & 2. For weights and dimensions.8 cu in (13. For weights and dimensions.4 cu in (6.com • Single air head • Drive pressure 3 to 150 psi (.18 cu in (3.4 ml) AFD. DSFD.2 to 7 bar) When using high pressure ratio pumps the reliability of the XH models (-452 through -1373) will be improved with an air driven supercharge pump. For weights and dimensions.3 cu in (22 ml) . ASFD -B60 6500 psi (448 bar) 1. DSF. see page 17. DSHF -302 50000 psi (3448 bar) .6 ml) 3. For service codes.7 cu in (44.6 ml) 1. ASF. This approach will ensure a reasonable life for the seals and other wear components. the better the results.6 cu in (26. DSTV -B22 -B32 -52 -72 -122 3200 psi (221 bar) 4800 psi (331 bar) 8000 psi (552 bar) 11000 psi (758 bar) 19000 psi (1310 bar) 4 cu in (66. see page 20. 2 hp distance Sour gas drive provision to N. www.5 hp and 2 hp pumps (not applicable to high output. 82500 ATEX 51050 Extreme service cycling 86337 Extended life air drive. 53925 Severe Arctic low temperature service.5 hp to 2. DFD. single acting.A.Optional Modifications (for 2 hp. Includes BZE6-2RQ microswitch.5 hp and 2 hp pumps. 29376 Three-way cycling spool. 16831 Low temperature For special sealing in air drive for operating temperatures from as low as -20°F up to normal +120°F. ½” NPT. ASFD or DSFD. Except 3 hp pump. piece pumps only. 16821 Number regulator. 55516 Polyurethane “W” seal in “F” series pumps-except high output models. 15 pump minimum. -10 ratio or higher.5:1 ratio and 3 hp pump. 55193 Extra foot bracket installed.5 hp and 2 hp single acting pumps. 5⁄8” SAE inlet and outlet – for 1. Except 1. -B22 and -B32) 1. 51345 1. 27964 28000 28003 28881 External air pilot. shut-off. “BR” on -B10. Threaded vent (or purge) ports on standard distance piece. -CO Air controls with recycle button. Applies to distance piece pumps only.5 hp to 2 hp pumps.2 hp and 3 hp pump models) Number Description -C Air controls -CP Air controls with precision regulator. 51331 EPR (Ethylene propylene) static seals in wetted section. -32 Rotate pump body 90° from standard. 55192 3/4 NPT inlet port installed on AWD series (in place of threaded port). -B Bottom Inlet (designate “B” before ratio dash number.5:1 ratio. -35.5 thru 2 hp pumps. -22. 55191 Mounting ring kit for AWD series. ½” NPT. 59353 Noise reduction kit 59888 Cycle timer installed. 54885 54935 SS trim for 5/3 air drive. chemical. With back pressure balance piston.2 hp pumps only. -450 ratios except 3 hp pump. except 1. Interconnecting inlet-outlet tubing. -151. Assures reliable drive operation with pressures low as 3 psi as long as 20 psi or more is provided to the separate 1⁄8” NPT port. or AWD series pumps) 52788 Viton seals. ½” NPT.haskel. For 1. -15. -150. Air drive only – 1. (not available on AW or DSXHW pumps). 25721 Mechanical stroke counter. 55305 Tube ports. Not recommended for long stall periods.com 13 . -B15. Provides access port in pump’s body between inlet and outlet check valves for 1. For 1. 29806 Double distance piece.C. gauge. -225. Except 3 hp pump. Test port. 2. 2. 55465 Ceramic Plunger -60 Ratio. -25. Installed (6 digit). 17860 Electrical stroke counter provision. ½” NPT. Description 51056 Exhaust/pilot vent combiner. -CPO Air controls with precision regulator and recycle button. 16834 Exhaust adapter.E. 55630 Stainless steel (SS-316) distance piece – for 1. Provides 1⁄8” NPT port for external air to pilot for remote start/ stop operation.5 hp to 2. -300. ½” female for 4:1 ratio series pumps (ATV-4 or DTV-4).2 hp. 29702 Single stroke 82460 HNBR Seals in air drive section. single air head and double air head. -60. 53925-4 Severe Arctic low temperature service. -10.5 hp and 2 hp pumps only. -100. 81453 3/8 HP outlet 81453-2 1/4 HP inlet Not available on AFD. Displacement per Cycle GWD.5 ml) (1) Double Acting “Lift” Pumps For service codes. see page 22.5 cu in (57 ml) 2. 8DFD. 9 possible combinations • Pressures to 30. water (plain or DI). solvents • Choice of wetted materials Incorporating 10 models. For drive pressures 3 to 40 psi (.5 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures.haskel.2 to 9 bar) • Flow rates to 21 gpm (80 l/min) • All hydraulic fluids. . GSFD.6 hp (4. For weights and dimensions. DGSF.com • All hydraulic fluids. -25(1) 4000 psi (276 bar) 14 cu in (229 ml) 8SFD -40 -65 6000 psi (408 bar) 10000 psi (690 bar) 9 cu in (145. GSF. Key Features • Choice of 10 models. this heavy duty range of double acting pumps provide pressures up to 10.5 ml) 8SFD2 (1) -55 -88 -224 7200 psi (496 bar) 10000 psi (786 bar) 29000 psi (1724 bar) 14 cu in (229 ml) 8.0 cu in (98 ml) 3.5 cu in (57. see page 17.2 to 2. 8DSFD. liquefied gases (1) Double Acting “Lift” Pumps • Choice of wetted materials • Single air head – double acting • Drive pressure 3 to 125 psi (. order 51875-1 mod.2 to 9 bar) For service codes. 8DSTVD 8FD Key Features • Choice of 9 models. 4 ratios.000 psi (690 bar) • Drive pressure 3 to 125 psi (. water (plain or DI).6 cu in (25. 20 possible combinations • Single air head – double acting • Output pressures to 10. DGSTV -35 -60 -100 4375 psi (302 bar) 7500 psi (517 bar) 10000 psi (690 bar) 6. For weights and dimensions.47 kW) Pump Models Model Nominal Ratio Maximum Working Pressure Consult chart on page 6 for more information regarding continuous/intermittent pressures. 8 ratios.8 and 9 bar).97 kW) Pump Models Maximum Working Pressure Displacement per Cycle Model Nominal Ratio 8SFD. DGF. solvents. DGSTVD(1) -12 4000 psi (276 bar) 15.83 cu in (144 ml) 3.5 gpm (44 l/min) 14 www. Designed to operate with air drive pressures between 40 and 125 psi (2.4 cu in (88.5 cu in (57 ml) 8HSFD -225(1) 25000 psi (1724 bar) 1.1 cu in (34. DGFD(1).8 bar).000 psi (2068 bar) • Flow rates to 11. see page 21. see page 17. DGSFD(1).2 ml) 8DSFD -100(1) 10000 psi (690 bar) 3.3 ml) 5.000 psi (690 bar) and flow rates up to 4 gpm (15 l/min).9 cu in (260 ml) GW.  8 hp (5. KS N:. 3XPS0RGHOV Model Nominal Ratio Maximum Working Pressure Consult chart on page 6 for more information Ài}>À`ˆ˜}ÊVœ˜Ìˆ˜ÕœÕÃɈ˜ÌiÀ“ˆÌÌi˜ÌÊ«ÀiÃÃÕÀið Displacement per Cycle D14STD £Óx­£® Σx­£® £ÈäääʫÈʭ££äÎÊL>À® ÎÈäääʫÈʭÓ{nÓÊL>À® n°nÊVÕʈ˜Ê­£{{°Óʓ® ΰxÊVÕʈ˜Ê­xÇ°{ʓ® D14SFD £Óx­£® Σx­£® £ÈäääʫÈʭ££äÎÊL>À® ÎÈäääʫÈʭÓ{nÓÊL>À® n°nÊVÕʈ˜Ê­£{{°Óʓ® ΰxÊVÕʈ˜Ê­xÇ°{ʓ® (1)Ê . For weights and dimensions. see page 17. see page 23. Key Features UÊ …œˆViʜvÊ{ʓœ`iÃ]Ê{ÊÀ>̈œÃ]Ê 4 possible combinations UÊ *ÀiÃÃÕÀiÃÊ̜ÊÎÈäääÊ«ÃˆÊ ­ÓxääÊL>À® UÊ œÜÊÀ>ÌiÃÊ̜ÊÎÊ}«“Ê­££ÊÉ“ˆ˜®Ê UÊ .œÕLiÊV̈˜}ʺˆvÌ»Ê*Փ«Ã For service codes. ÀˆÛiÊ«ÀiÃÃÕÀiÊÎÊ̜ʣÓxÊ«ÃˆÊ ­°ÓÊ̜ʙÊL>À® UÊ Ê…Þ`À>ՏˆVÊyՈ`Ã]ÊÜ>ÌiÀÊ ­«>ˆ˜ÊœÀÊ. 29079 Interconnecting tubing – 10 hp pumps. 57944 Viton seals – air drive only – 8 hp. 54936 Exhaust/pilot vent combiner. 55330 Interconnecting tubing 8DSFD-100 low pressure inlet. 29077-1 Interconnecting tubing – 6 hp and 8 hp pumps. 54030 Sour gas air drive provision to NACE spec.com 15 . Optional Modifications (for 6 hp. slow speed pumps approach a seal life as high as 5 times that of many smaller pumps and this advantage becomes ever greater in heavy duty service involving water. 29077 Interconnecting tubing – 6 hp and 8 hp pumps. 29078 Same as 29077. GSF. 29077-1 double ended w/distance piece. 29078-1 Same as 29077. not available on 8 hp or 14 hp drive. 54312 Extreme service cycling 17860 Electrical stroke counter provision (includes BZE6-2RQ micro switch). 55330-1 Interconnecting tubing 8DSFD-100 high pressure inlet. 57002 Viton seals – air drive only – 6 hp. – for 6 hp thru 10 hp pumps. 29702-2 Single stroke. These large. 25721 Mechanical stroke counter installed (6 digit).haskel. – for 6 hp thru 10 hp pumps. this heavy duty range of double acting pumps provide pressures up to 36000 psi (2482 bar) and output flow rate up to 3 gpm (11 l/min). nor on ATEX GW. 6 hp distance piece pumps only. Operating from a maximum air drive pressure of 125 psi (9 bar). 86337 Extended life air drive. 8 hp and 10 hp pump) Number Description Number Description C Air controls. or other liquids with negligible lubricity. double ended low ratio pumps. these pumps are designed for medium to high pressure service with minimum maintenance. 29125 External pilot 82500 available for 6 hp only. or DGSFD models. 59888 Cycle timer installed. www. GSFD. 29077-1 double ended w/distance piece low ratio pumps. double ended. 87410 Low air pressure control – for 6 hp thru 10 hp pumps.®]Ê܏Ûi˜ÌÃ]Ê liquefied gases UÊ …œˆViʜvÊÜiÌÌi`ʓ>ÌiÀˆ>Ã Incorporating two basic models. DGSF. 55366 Interconnecting tubing 8DSFD-225. Component manufacturers are required to provide test certification and product quality assurance which can only be determined using the types of systems which Haskel can provide. Our representatives around the world are carefully chosen and trained to help you arrive at a correct product choice. and other applications where reliable power is needed. leak. • • • • • 16 Air pilot switches Air pilot valves Regulating relief valves Directional control and release valves Hydraulic accumulators. mobile.com • High pressure valves. we have built systems for production and field testing the proof. gas receivers and storage cylinders www. Typically. These systems can be portable. Quality and After-Sale Service Haskel meets the requirements of international quality assurance ISO 9001. Haskel can customer nominated accessories. and valves. We also offer a range of standard pressure packs used for power jacking. fittings and tubing • Plenum chambers • Port adapters • Gauge snubbers • Filters • Stainless steel check valves Intensifiers with integral checks for cycling • Capillary type gauge snubbers Please ask for your copy of our latest accessories brochure. . and to offer a maintenance and parts service that is second to none. Our accessories catalog is available and our technical support team is always ready to advise you on the most suitable choice of accessories for your application. Selecting Your Accessories Haskel can either provide accessories separately or supply them fitted to form a complete package suited to your application. and burst aspects of hoses. Build quality is matched by an innovative design and problem solving ability which stems from years of years of experience. or static test rigs. Additionally. clamping.haskel.Power System Specialists World safety standards and quality demands are rising. cylinders. aromatic hydrocarbons (benzene. we have classified various popular liquids in groups and assigned to each group a service code. please contact our technical services personnel at 818-843-4000.). ethylene glycol.. specify number 51331 (no extra charge). Services hp .g.33 3 • • • • • • • • • • • • • • • • • • • MDTV MDSTV 29723 4B -14 to -37 4B -55 to -150 DSXHW • • • • • • • • • • • • • • • • • • • ASFD • GW • • • • • • • • • • AW ASF DF DSF HF HSF DHF DSHF 1. 135° C (275° F) for T and TV models (with distance piece).).5 AFD DFD ASFD DSFD DXHF DSXHF 3 GSF DGF DGSF DGSTV 6 GWD GSFD Operating Temperatures DGFD Drive Section -4° (25°F) to +65°C (150°F) (low temperature seals are available for Arctic operation). methyl acetone. etc. Dowtherm A. Cellulube. chlorobenzine. solvents etc. 2 M MCPV Services 5 Skydrol and Aerosafe hydraulic acetone and some alcohols (ethyl. e. high temperature should be limited to 54° C (130° F). carbon tetrachloride.g.com 17 . Liquid Section For reasonable seal life. Lindol. and isopropyl). Dowtherm E. diesel fuel. 6 Deionized water. demineralized water. methyl. Seals and other wetted materials can be supplied to suit your preferred liquid. Fyrquel. 1 MS . Note: Dynamic seal life with non-lubricating fluids will understandably be less than with lubricating types. e. Pydraul. for F and W seal models. hylene. 51331-MDTV-5. mercaptans. Model DGSFD DGSTVD 8FD 8SFD 8 8SFD2 8DFD 8DSFD 8DSTVD 10 • • • • • • 4 5 • • • • • • • • • • • • • • • • • • • • • • • • • • • • 6 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 8HSFD • • • • • • D14STD -125 • • • • • • • • • • • • • • • • • • • • • • D14STD -315 D14SFD -125 D14SFD -315 www. Also suitable for these if Viton static seals are replaced with EPR. toluene.haskel.75 Service Codes 1 Petroleum-based oils. kerosene. These service code numbers are featured in the chart to the right and are designated for each pump series. diacetone.Liquids Compatible with Haskel Pumps To assist in easier pump selection. xylene. For advice. 5A. Most phosphate esterbased solidify at approximately 30000 psi.).5 2 2. alcohol and freon 22. See note 5A for service with methylethyl-ketone. 4 Petroleum-based solvents. and Houghtosafe 1120 and petroleum-based solvents compatible with UHMWPE (Ultra-high Molecular Weight Polyethylene) dynamic seals and Viton static seals. plus all of Group 3 and some mildly corrosive acids compatible with wetted materials. 3 Most phosphate ester-based hydraulic e. chlorinated solvents (trichlorethylene. water with 5% soluble oil.2 DSTV ATV DTV DSTV -1.g. 2 Plain water. etc. weight 6 lbs (2. M-36.5 kg Box size 30 x 20 x 15 cm Net weight 2.25 kW) M Series Pump Models Net weight 4 kg Boxed weight 4. Plan view of M-Pump is common to all M-Series pumps. M-110. M-188 approx.75 kg Box size 23 x 18 x 12 cm MS-21. weight 9 lbs (4 kg) MS-7. MS-12 approx.7 kg) M-5 approx.5 kg Boxed weight 2.com M-21. weight 6 lbs (2.7 kg) MS-220 approx.33 hp (. MS-36.haskel. MS-188.7 kg) 18 www. MS-110. approx. Net weight 2.075”) Weights and Dimensions 206 mm (8”) .25 kg Box size 23 x 18 x 12 cm M-7.NB.91 mm (. M-12 approx.9 kg Box size 23 x 18 x 12 cm 11.65 kg Boxed weight 2. weight 9 lbs (4 kg) . weight 9 lbs (4 kg) Net weight 6 kg Boxed weight 6. M-71. weight 6 lbs (2. MS-71. 29723-21. 4B-21. 29723-110 approx.56 kW) Pump Models Model 4B-14. 4B-25 and 4B-30 Model 4B-55 and 4B-75 www. 29723-71.com 19 . 29723-36. MDTV Approx weight 15 1/2 lbs (7 kg) .5 lbs (3 kg) MDSTV-5 . weight 6.haskel.75 hp (. KS KS  N:. -202 and -302 ratios 20 www. -B10 and -B15 ratios iÌÊÜiˆ}…ÌÊ£{ʎ} œÝi`ÊÜiˆ}…ÌÊ£xʎ} œÝÊÈâiÊxÓÊÝÊ{äÊÝÊ{äÊV“ (-52.3XPS0RGHOV DSFD-B60 iÌÊÜiˆ}…ÌÊ£nʎ} œÝi`ÊÜiˆ}…ÌÊÓäʎ} œÝÊÈâiÊÈnÊÝÊ{ÓÊÝÊxäÊV“ iÌÊÜiˆ}…ÌÊ£äʎ} œÝi`ÊÜiˆ}…ÌÊ££ÊŽ} œÝÊÈâiÊÎÇÊÝÊÎÇÊÝÊÎnÊV“ 25. -122. +22) ⁄4 HP port (-202. -302) 1 1. -72. -683 and -903 ratios 1.haskel.5 and 2 hp medium ratio pumps.com 2 hp (1.5 and 2 hp low ratio pumps.4 mm = 1 inch 2 hp high ratio pumps.64 kW) Pump Models. -52.49 & 1. -1373 ratio . -72. : 3W XP F lRsQ (W c  .KS   (N. 7 5 hp 5 6. ) .o n t .  k ) S P u0mRpG HMO V o d e Model 4B-37 approx.12.49 & 1.2 hp (1.com 21 .5 hp. 2&2. weight 10 lbs (4.haskel. 1. weight 11 lbs (5 kg) 1.64 kW)Pump Models DSFD-B60 www.5 kg) Model 4B-100 & 4B-150 approx. 2 hp (1.1. -B10 and -B15 ratios iÌÊÜiˆ}…ÌÊ£{ʎ} œÝi`ÊÜiˆ}…ÌÊ£xʎ} œÝÊÈâiÊxÓÊÝÊ{äÊÝÊ{äÊV“ 25. 2&2.5 and 2 hp low ratio pumps. high output œÌi\ÊœÀʓœ`iÊ. 122) Liquid Outlet 1 ⁄4 HP port (-202. -52.5 and 2 hp medium ratio pumps.49 & 1.49 & 1. -72. -1373 ratio iÌÊÜiˆ}…ÌÊ£nʎ} œÝi`ÊÜiˆ}…ÌÊ£™ÊŽ} œÝÊÈâiÊ{xÊÝÊÎÇÊÝÊ{{ÊV“ ATV-4 pumps.64 kW) pump models. -122.12.5 hp.4 mm = 1 inch 2 hp high ratio pumps. 1. -202 and -302 ratios ˆquid Inlet £ÉÓ»Ê *T ˆÀÊ Ý…aust 1ÉÓ»Ê *T 241 mm ­™Ê£ÉÓ»® iÌÊÜiˆ}…ÌÊ£äʎ} œÝi`ÊÜiˆ}…ÌÊ££ÊŽ} œÝÊÈâiÊ{xÊÝÊÎÇÊÝÊ{{ÊV“ 2 hp (1. double acting.) iÌÊÜiˆ}…ÌÊ£nʎ} œÝi`ÊÜiˆ}…ÌÊÓäʎ} œÝÊÈâiÊÈnÊÝÊ{ÓÊÝÊxäÊV“ iÌÊÜiˆ}…ÌÊ£äʎ} œÝi`ÊÜiˆ}…ÌÊ££ÊŽ} œÝÊÈâiÊÎÇÊÝÊÎÇÊÝÊÎnÊV“ 1. -72.64 kW)Pump Models (cont. -302) 1 394 mm ­£xÊ£ÉÓ»® Breathers ir Drive Inlet 1ÉÓ»Ê *T 1. -683 and -903 ratios ⁄2” NPT (-52. add distance piece dimension from page 11. 22 www. single acting.5 pump.haskel. high output ˆquid Outlet 3É{»Ê*Ê*œÀt 24x mm ­™ÊxÉn»® ./6-4.com DSTV-1. Interconnecting inlet and outlet port tubing shown. double acting. -300* and -450* ratios *1⁄4” Super Pressure Outlet Port Hydraulic Outlet Port 1/2” NPT (2 places. -B60.24 kW) Pump Models AIR DRIVE INLET PORT 1/2” NPT MODEL ASFD-15 OUTLET PORT 1/2” NPT OUTLET PORT INLET PORT ASFD-25 ASFD-25ASFD-35.com 23 . -151*.5 and 2 hp medium and high ratios. -225*. ASFD-60ASFD-150 pressure 1/2” NPT } ASFD-100 OUTLET PORT 1/2” NPT ASFD-150 3/8” MEDIUM PRESSURE 9/16-18 THREAD ASFD-10 ASFD-202 OUTLET PORT 1/2” NPT www www. -25 through -150. ASFD-35ASFD-60 1/2” NPT ASFD-100 3⁄8" med.haskel. this side) 144 mm (5 11/16”) 105 mm (4 5/32”) (TYP) Hydraulic Inlet Port 1/2” NPT (2 places. -B100 pumps.iÌÊÜiˆ}…Ìʙ°xʎ} œÝi`ÊÜiˆ}…ÌÊ£äʎ} œÝÊÈâiÊÓxÊÝÊÓÈÊÝÊÓÓÊV“ 11 mm (7/16”) (TYP) (9 7/8”) 119 mm (4 11/16”) Mounting Bracket (2 places) 76 mm (3”) Handle ⁄2” NPT Liquid Outlet* 1 279 mm (11”) 413 mm (15 1/4”) Air Drive Exhaust Port 1/2” NPT 64 mm (2 1/2”) Air Drive Inlet Port 1/2” NPT 154 mm 17 mm (6 1/16”) (11/16”) 1. this side) 102 mm (4”) 209 mm (8 1/4”) ATV-8 pumps AFD or ASFD. high output 3 hp (2. KS N:. DGSTV nominal ratio 35. DGSF. Models GW. DGSFD. GSFD nominal ratio 12:1 iÌÊÜiˆ}…ÌÊÈÈʏLÃÊ­Îäʎ}® œÝi`ÊÜiˆ}…ÌÊÇxʏLÃÊ­Î{ʎ}® œÝÊÈâiʙ£ÊÝÊx£ÊÝÊΙÊV“ If interconnecting piping for the two inlets and two outlets is required. specify modifiV>̈œ˜ÊәäÇÇÊ܈̅ÊޜÕÀʜÀ`ir.com . DGSTVD nominal ratio 12:1 24 www.3XPS0RGHOV iÌÊÜiˆ}…ÌÊΣʏLÃÊ­£{ʎ}® œÝi`ÊÜiˆ}…ÌÊÎxʏLÃÊ­£Èʎ}® œÝÊÈâiÊxÓÊÝÊΙÊÝÊΙÊV“ Ê“œ`iÃʅ>ÛiÊÓʜvvÊ11⁄4” */Ê>ˆÀÊi݅>ÕÃÌÊ«œÀÌÃÊ and 1 off 3⁄4»Ê */Ê>ˆÀÊ`ÀˆÛiÊ inlet ports. specify modifiV>̈œ˜ÊәäÇnÊ܈̅ÊޜÕÀʜÀ`ir. GSF nominal ratio 35. Models DGFD. 60 100:1 iÌÊÜiˆ}…ÌÊxÇʏLÃÊ­ÓÈʎ}® œÝi`ÊÜiˆ}…ÌÊȣʭÓÇʎ}® œÝÊÈâiÊÈÈÊÝÊ{£ÊÝÊ{™ÊV“ If interconnecting piping for the two inlets and two outlets is required. 60 100:1 iÌÊÜiˆ}…ÌÊ{£ÊLÃÊ­£n°xʎ}® œÝi`ÊÜiˆ}…ÌÊ{nÊ­ÓÓʎ}® œÝÊÈâiÊÈÈÊÝÊ{£ÊÝÊ{™ÊV“ Models DGF.haskel. Models GWD. 21 [132 mm] AIR DRIVE INLET PORT 3/4" NPT (130 PSIG MAX) 22.88 [124 mm] 2X LIQUID OUTLET PORT 3/8" HIGH PRESSURE (25.00 [178 mm] 8.000 PSIG MAX) 7.96 [278 mm] 10.36 [288 mm] 4X MOUNTING HOLES n 9/16" Models 8HSFD-25.97 kW) Pump Models 9.66 [703 mm] 5. 8FD-25.com 25 .25 [210 mm] 5. 8SFD-25 Inlet.17 [258 mm] 2X AIR DRIVE/SEAL SECTION VENT PORT 1/4" NPT 4.000 PSIG MAX) 10.65 [245 mm] 27.8 hp (5.haskel. Outlet ports 3/8’’ HP Models 8DSFD-25 & 8DSTVD-25 Model 8SFD-40 Model 8SFD-65 www.78 [147 mm] 11.93 [582 mm] CYCLING SPOOL ACCESS 2X LIQUID INLET PORT 3/8" HIGH PRESSURE (25. KS N:. 3XPS0RGHOV FRQW. 10 in [282 10.25 in [108 mm] 7.92 in [760 mm] Model 8SFD2-55 8X .com 4.55 in [496 mm] 28.10 in [282 mm] 10.88 in [124 mm] 2X HYDRAULIC INLET 1 1/4" NPT PORT 4.17 in [258 mm] 4.00 in [178 mm] 8.11 in [460 mm] 19.48 in [673 mm] 29.55 in [496 mm] 8.25 in [210 mm] .25 in [210 mm] 26.25 in [108 mm] 18. 8X .88 in [124 mm] 2X HYDRAULIC INLET 1 1/4" NPT PORT 18.17 in [258 mm] 4.00 in [178 mm] 19.06 in [814 mm] Model 8SFD2-88 26 www.65 in [245 mm] AIR DRIVE INLET 3/4 NPT 2X HYDRAULIC OUTLET 1" NPT PORT 11.80 in [858 mm] AIR DRIVE LET 3/4 NPT 2X HYDRAULIC OUTLET 1" NPT PORT 11.53 in [13 mm] (MOUNTING HOLES) 9.11 in [460 mm] 7.65 in [245 mm] 33.62 in [727 mm] 32.53 in [13 mm] (MOUNTING HOLES 32.73 in [831 mm] 9.haskel. HYDRAULIC OUTLET 3/8 HP PORT (MAWP: 29.78 in [909 mm] 37.000 PSI) HYDRAULIC INTLET 1/2 NPT PORT (MAWP: 10.000 PSI) HYDRAULIC INLET 1/2 NPT PORT (MAWP: 10.com 27 .11 in [460 mm] 4.46 kW) Pump Models Model D14STD-125 Model D14STD-315 www.17 in [258 mm] 4.000 PSI) 8X .25 in [108 mm] 19.25 in [210 mm] Model 8SFD2-224 10 hp (7.65 in [245 mm] AIR DRIVE INLET 3/4 NPT 11.000 PSI) HYDRAULIC OUTLET 3/8 HP PORT (MAWP: 29.haskel.00 in [178 mm] 35.55 in [496 mm] 7.10 in [282 mm] 10.78 in [960 mm] 8.53 in [13 mm] (MOUNTING HOLES) 9.88 in [124 mm] 18. visit Haskel.com sales@ha askel skkel.com or contact your local Haskel representative.com h ha sk kell.co . haskel. Haskel is a brand of Accudyne Industries.com com om sales@haskel. The company is powered by more than 3. process-critical and technologically advanced flow control systems and industrial compressors that deliver consistently high performance and give confidence to the mission of our customers in the most important industries and harshest environments around the world.c ell.For more information on our high-pressure products.000 employees at 18 manufacturing facilities.c com c om 37. supporting a broad range of industries in more than 150 countries.c .3 7YPU[LKPU<:( . a leading global provider of precision-engineered.
Copyright © 2024 DOKUMEN.SITE Inc.