Hach Lange Catalogue i

March 24, 2018 | Author: Παναγιώτης Τσάβας | Category: Sewage Treatment, Ph, Environmental Monitoring, Battery (Electricity), Water Purification


Comments



Description

WASTEWATER DRINKING WATER PROCESS WATERLABORATORY ANALYSIS LABORATORY AUTOMATION SAMPLERS PROCESS MEASUREMENT CATALOGUE 2006 / 2007 Welcome! New demands and technologies continuously spur us on to develop new and better solutions to the problems you encounter in everyday analysis. The proof of this can be found in our latest catalogue. Amongst our wide range of market leading products you will find: – An impressively large selection of photometric methods for the laboratory, with the latest in Spectrophotometry; the DR 2800 and DR 5000 – Outstanding measuring reliability and flexibility for pH and oxygen with the new digital HQD systems – A wide range of applications for the new TOC automatic laboratory analysers – Reliable solutions from the new process analysers for N and P parameters – Innovative new telemetry service for process measurement technology – Latest technology for monitoring the quality of surface water All this and more – take a look for yourself! The ideal team for water analysis On-site support BÜHLER DR. LANGE Technical support and orders EVITA GLI HACH LACHAT POLYMETRON RADIOMETER ANALYTICAL SIGMA Quality assurance Seminars and workshops Disposal and recycling Web Shop and downloads Customer information Service and maintenance www.hach-lange.com CONTENTS 3 Introduction Parameters, wastewater, drinking water, process water, service, water quality Page 4 Chapter 1 Laboratory analysis HACH LANGE laboratory solutions ensure accurate and reliable analysis for all parameters in the municipal, regulatory and industrial sectors. In the lab and in the field. OVERVIEW pH, O2, CONDUCTIVITY PHOTOMETER REAGENTS BOD, MICROBIOLOGY TURBIDITY ACCESSORIES Page Page Page Page Page Page Page 16 18 29 41 68 73 77 Chapter 2 3 4 5 6 7 8 Laboratory automation HACH LANGE solutions for automated analysis LABORATORY AUTOMATION Page 83 Chapter 9 Samplers HACH LANGE solutions for stationary and portable sampling SAMPLERS Page 91 Chapter 10 Process Measurement Technology HACH LANGE process solutions for drinking water, wastewater and industrial treatment systems and industry. Providing reliable instrumentation, cost effectively. OVERVIEW CONTROLLERS TURBIDITY, SOLIDS, SLUDGE PARAMETERS pH, O2, CONDUCTIVITY NUTRIENTS TOC, SAC CHLORINE, OZONE OTHER PARAMETERS FLOW MOUNTING KITS Seite Page Page Page Page Page Page Page Page Page Page 87 95 96 101 111 121 135 139 141 142 144 Chapter 11 12 13 14 15 16 17 18 19 Kapitel 20 Reference Contact us, parameter index, product name index Page 146 Chapter 21 BOD and AOX provide no direct information about individual substances. ➔ Laboratory analysis: see page 16 ➔ Laboratory automation: see page 83 ➔ Process measurement technology: see page 95 Nutrients Nitrogen and phosphorus compounds are not toxic.com . but are sum parameters which indicate. HACH LANGE sum parameters offer perfect solutions. TOC. total nitrogen. special attention is paid to nitrite and nitrate as potential precursors of carcinogens. nitrate. From wastewater. and makes use of fast and effective digestion methods. pH. Suspended solids and particles can effect the end product and may also interfere with the process. including proven. HACH LANGE has developed an extensive range of products using its outstanding advanced technologies. orthophosphate and total phosphate plays a key role in wastewater treatment processes. HACH LANGE offers everything from individual analysis in the laboratory to on-site process analysis. For TOC analysis. HACH LANGE has a comprehensive range of products for determining the lowest to the highest solids content as well as key sludge properties. O2. drinking water to process water. HACH LANGE nutrient analysis covers all parameters. the chemical or biological oxygen-consuming capacity or UV absorption of water. ➔ Laboratory analysis: see page 16 ➔ Process measurement technology: see page 95 Turbidity and sludge Clear water is the desired end product of wastewater and drinking water treatment. We have the right solutions for you. The conductivity of water provides information about its salt content. but encourage the growth of algae in surface waters.hach-lange. In view of the importance of these parameters. SAC.4 1_INTRODUCTION ➔ Laboratory analysis: see Chapter 2-8 Practical solutions— parameter by parameter The HACH LANGE product range covers the complete spectrum of parameters in water analysis. The determination of turbidity is therefore an important task. nitrite. sludge volume. easy handling. The central role of active sludge in the wastewater treatment process needs careful monitoring: with parameters such as the solids concentration. for example. ➔ Laboratory analysis: see page 16 ➔ Process measurement technology: see page 95 Sum parameters COD. ➔ Laboratory analysis: see page 16 ➔ Laboratory automation: see page 83 ➔ Process measurement technology: see page 95 www. Its precise measurement is of major technical and economic significance. In the analysis of drinking water. Whether in the lab or in the field. The elimination of ammonium. which results in oxygen depletion. The pH and redox values of wastewater and drinking water are essential for the assessment of many other parameters and process steps. sludge index and sludge level. conductivity Dissolved oxygen concentration influences wastewater purification more than any other parameter. fast digestions. they are all rated as having a very high risk potential. so a special sample preparation has to be carried out before the analysis can be performed. Hazen and Gardner in industrial quality control. It is essential. sulphate and silica in water treatment systems. From paddle testers through to quality controlled laboratory analysis and analysers for process control applications. products such as chlorine dioxide. Ready-to-use tests. copper and nickel to zinc. iodine and bromine are used. the luminescent test uses bacteria as a tool to determine the toxicity of water and soil. since disinfectants and their reaction products are associated with risk potential. from aluminium. ➔ Laboratory analysis: see page 16 ➔ Process measurement technology: see page 95 Metals Many metals from industrial processes may be present in wastewater. MPN. Metals are usually present in water samples in complex forms. media and accessories are available. biogas fermenters and digesters. such as monitoring a process or a legally specified value— cyanides or surfactants in industrial wastewater. ➔ Laboratory analysis: see page 16 Microbiology Bacteria. ➔ Laboratory analysis: see page 16 ➔ Process measurement technology: see page 95 . Presence/Absence. chloride. BART and paddle testers. ➔ Laboratory analysis: see page 16 Other parameters Special parameters need to be analysed in water for many reasons. Metals may also be present in drinking water due to geological circumstances and corroded pipes. colour values such as iodine. HACH LANGE has a complete range of products for disinfection analysis. Besides chlorine. while in industrial plants they may form troublesome coatings. e. g. In contrast. fungi and other microorganisms in drinking water and recreational water can be a cause of disease. membrane filtration. Although the toxicity of metals varies widely. Careful analysis of these substances is not just advisable on economic grounds. The HACH LANGE range of products enables quantitative and qualitative microbiological tests of surfaces and water to be carried out in conformity with legal requirements. ozone. Metals are not biodegradable and therefore accumulate in activated sludge systems. and many others. hardness in drinking water. HACH LANGE metal analysis covers all relevant parameters. HACH LANGE can supply a comprehensive range of products for a variety of parameters and needs.5 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Wastewater Made-to-measure solutions for wastewater analysis in the municipal and industrial sectors Drinking water Dependable analysis for providers and users Process water Process and laboratory analysis for special analytical problems Chlorine Disinfectants are used to eliminate microorganisms from drinking water and recreational water. together with a variety of methods. organic acids in aeration tanks. (L) laboratory only (P) process only Acid capacity Ammonium Nitrate Oxygen pH Phosphorus. HACH LANGE wastewater analysis is the result of decades of practical experience. ortho Sludge volume (P) Sludge volume index (P) Solids (P) AOX (L) BOD (L) COD (L) Conductivity Cyanides (L) Metals (L) Nitrogen.6 1_INTRODUCTION ➔ Laboratory analysis: see Chapter 2-8 WW For municipal and industrial users— HACH LANGE wastewater analysis Wastewater is one of the main waste products of our society. total (L) pH Surfactants (L) TOC SAMPLER Cyanides (L) Metals (L) Surfactants (L) Toxicity (L) Conductivity Flow (P) pH SAC (P) Solids (P) TOC Solids (P) Sludge level (P) Municipality Prim ary s ettli ng Industry Cha nnel Scre en/g rit c ham ber Stor m-w ater tank Receiving water Flow (P) www. To ensure that it can be returned to the natural water cycle without harming the environment.com . Threshold values can only be monitored correctly and treatment processes can only be controlled economically with the help of accurate and reliable analysis. producers of wastewater are obliged to comply with certain minimum requirements. Innovative solutions for a wide range of parameters in the industrial and municipal sectors.hach-lange. total Surfactants (L) TOC SAMPLER Receiving water Ammonium Nitrate Organic acids Oxygen pH Phosphorus. ortho SAMPLER Sludge level (P) Solids (P) Turbidity Filte r Fina l sed imen tatio n Thic kene r Aera tion Pr slu im dg ar e ys lu dg e Re cy cle d Ammonium Flow (P) Conductivity Nitrate pH Phosphate. ortho itori ng o Phosphorus. total SAC (P) TOC Turbidity Slud ge d ewa terin g Dige ster Solids (P) Organic acids (L) Solids (P) Pri settl mary ing Slud ge d ewa terin g Prim ary s ettli ng di sp os al Sl ud ge . ortho Phosphorus.7 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Ammonium Chloride Chlorophyll (P) Chromium (VI) Conductivity Nitrate Oxygen pH Mon Phosphorus. total (L) pH Phosphorus. total f sur Redox potential face wate Temperature rs TOC Toxicity (luminescent bacteria) Turbidity WW Ammonium AOX (L) BOD (L) Chloride COD (L) Conductivity Cyanides (L) Fluoride Metals (L) Nitrate Nitrogen. Drinking water analysis solutions from HACH LANGE gives you confidence in drinking water treatment and use.com . Consumers and suppliers alike expect it to be of the highest quality and legislation dictates this. HACH LANGE is an expert with years of experience in drinking water analysis.8 1_INTRODUCTION ➔ Laboratory analysis: see Chapter 2-8 DW HACH LANGE drinking water analysis— solutions for suppliers and consumers Drinking water is essential to human life. We provide proven solutions for all relevant parameters in the field.hach-lange. in the laboratory or process control. (L) laboratory only (P) process only Nitrate pH Turbidity Conductivity Hardness pH Turbidity Nitrate pH Turbidity Hardness To c ollec ting tank Den itri Iron (L) Manganese (L) Microbiology (L) Nitrate SAC Turbidity Soft enin g Fir filtrst stag atio e n Sedi men tatio n Floc cula tion Spra ying Spring/Well Scre en/g rit c ham ber Pri trea mary oz tme one nt Ozone pH Aluminium (L) Iron (L) Phosphorus Surface waters Bank Filtrate/Groundwater Recharge Conductivity Microbiology (L) pH SAC Turbidity www. 9 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 DW Chlorine Chlorine dioxide Hardness Iron (L) Chlorine Chlorine dioxide Microbiology (L) Conductivity Turbidity Nitrate pH SAC Turbidity Distribution network Chlorine Chlorine dioxide Fine turbidity (P) pH SAC Turbidity Elev ated tank fica tion Mul tilay er fi lter/ acti ve c arbo n fil ter Ozone Mem bran e fil trat ion Clea r-wa Pum ter t p fo ank r ad ding chlo rine Fina l ozo ne t reat men t Turbidity Turbidity Coll ecti ng t ank Slud ge d ewa terin g Turbidity Sludge level (P) Solids content (P) Se wa ge tre at m en tp lan t . Not just from companies themselves. but also for special areas in a variety of industrial sectors. for widely varied applications such as cooling and boiler water. Verified data is needed about product quality.hach-lange. but also customers and legislators.g.com .10 1_INTRODUCTION ➔ Laboratory analysis: see Chapter 2-8 PW HACH LANGE process water analysis— solutions for industry The control of industrial production processes is under scrutiny from many sides. energy consumption and operating procedures. e. (L) laboratory only (P) process only Acid capacity Alkalinity Ammonium Chloride Chlorine COD (L) Copper (L) Conductivity DEHA (L) Hardness Hydrazine Iron (L) Molybdenum (L) Nitrite Oxygen pH Phosphonate Phosphorus SAC (P) Silica Sodium Sulphite TOC Toxicity (L) Turbidity Chlorine Conductivity Hardness pH Oxygen Silica Turbidity Coo ling and boile r wa ter Receiving water Wat er co ndit ionin g Prod ucti on Raw mat erial s www. HACH LANGE offers an extensive programme of analytical solutions for industry. etc. Only practice related and reliable analysis can supply this data. g. nitrite. hardness. fluid measurement. chlorine. nitrate. opalescence in conformity with Pharm./PETRO INDUSTRY: e. bitter units. beer colour. TOC. surfactants.g. vicinal diketones and other MEBAK parameters.g. TOC. cyanide. … PHARMA: e. … CHEM. iodine. AOX. 5.11 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 PW BOD (L) Chlorine COD (L) Conductivity Cyanide (L) Metals (L) Nutrients pH Oxygen SAC (P) Surfactants (L) TOC Turbidity Conductivity Oxygen pH Redox Turbidity Receiving water Wa ➔ Fstewate see or mor r treatm pag e in ent e 6 form atio n Neu trali satio n PAPER INDUSTRY: e. … ELECTROPLATING: e. Gardner. turbidity. turbidity.g. TOC. AOX. … . Eur. … BREWING/BEVERAGE INDUSTRY: e.0. formaldehyde. chromium (VI). Hazen. bath analysis for copper and nickel. starch.g. com . Service Package 3: Service-Plus contract On-site service plus teleservice for SC-based process measurement technology: service engineer call-out as required and as scheduled in the maintenance contract. HACH LANGE has developed comprehensive service packages to suit customers needs. We provide documentation for quality assurance purposes and for the reliable operation of the measurement systems. Plus round-theclock monitoring. Service Package 1: One-off Inspection Flexible assurance without contractual ties: ensuring a high level of continuity with the instruments thanks to replacement of wear parts or repairs as necessary. to keep up to date at all times with event reports by SMS. www.hach-lange. Flexible service packages provide the necessary assurance for smooth operation of the instrument. HACH LANGE supports the use of its instruments throughout their life cycle. call-out. Drawing on decades of practical experience.12 1_INTRODUCTION ➔ Laboratory analysis: see Chapter 2-8 WW DW PW Service Solutions—flexible packages Our customers depend on the availability of reliable analytical data at all times. Production Advice input: Service Visual Research + Development Initial start-up Technical support Disposal + Recycling Seminars + training Repair On-site maintenance Certificates Lease instruments Start-up service package: Initial start-up + Commissioning From the very first day our qualified staff will offer support during commissioning. Service Package 2: Inspection + Maintenance 60 month warranty period: regular inspections of the instruments in line with the maintenance contract. labour and spare parts are included. from initial start-up to disopsal. For a long instrument life and reliable operation with no hidden costs. At the same time.hach-lange. Teleservice—the new SC-based service 24 hours a day. Documented service— documented quality With regard to the monitoring of measurement and test equipment. so the engineer has all the necessary parts with him. www. 7 days a week: the SC 1000 controller informs the appropriate personnel about the connected SC process sensors by SMS. Service Support – for more information about HACH LANGE Service go to www.hach-lange. If necessary.co.13 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Face to face—personal support from the very first day Initial start-up and thorough instruction by qualified engineers are part of the course with HACH LANGE service. Plant visits can also be prepared more efficiently. they contact you by phone or intervene directly to take corrective action. Tested on site—for example the inspection report Regular and preventive inspections are fully traceable through individual inspection reports. HACH LANGE provides all documentation required by DIN ISO 9001:2000. Quick and convenient way of reporting faults. the event or alarm messages are sent to the HACH LANGE Teleservice Centre for analysis by skilled engineers. The HACH LANGE flexible service contracts give customers the satisfaction of having done everything to ensure correct set up of the instrument on site. verification of operational processes and comprehensive internal quality management.uk. ensuring the continued operation of the instruments. We ensure that you have a comprehensive knowledge of operating and maintenance of the instruments.com . The aim of the monitoring is to catalogue the current water quality for the desired restoration of the river basin to a good ecological condition. www.14 1_INTRODUCTION ➔ Laboratory analysis: see Chapter 2-8 Total solutions for monitoring water quality ➔ Comprehensive measurement stations. The physical. The service includes the complete delivery of power. chemical and biological measurement systems have proven themselves in all kinds of applications. The regional authorities responsible for river basins have been given the task of implementing the programmes. Monitoring stations are individually planned and constructed.hach-lange. stationary and portable ➔ Made-to-measure analysis equipment ➔ Remote diagnosis and data transmission via GSM ➔ For industrial monitoring that conforms with the IPPC Directive LDO SC Controller pH Turbidity Conductivity Nitrate SAC 254 EU monitoring Regulations from 2006 The timetable for the implementation of the European Water Framework Directive requires the EU member states to have programmes in place by the end of 2006 for monitoring river basins. HACH LANGE can offer a comprehensive service. and the equipment covers all the necessary parameters. precise sampling in water Simple implementation with turnkey equipment As an experienced producer of water analysis systems. Sediment outlet Outflow Sediment outlet Outflow Inflow Probes mounted in sample holder. The turnkey solution from HACH LANGE helps companies implement the EU directive.com . Sulphate. keyword “Water quality” .uk. built to specification and fully equipped Stationary industrial container. as well as: • Ammonium • Flow • Level measurement • Luminescent bacteria test in compliance with DIN EN ISO • Phosphorus (total and ortho) • Rainfall • TOC Parameters Sample delivery Data communication USB memory stick Submersible pump Pressure pump Suction pump GSM Submersible pump Pressure pump Suction pump GSM. Manganese. Nitrate. Chlorine. Ammonium. www.g.15 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Measurement station. submersible or pressure pump Turnkey total solutions—possible configurations Characteristics DREL mobile laboratory. Sulphite. Bromine.hach-lange. Iron. Hardness. available in a variety of versions Pump in operation. Chromium (VI). Molybdenum. Manual Mobile measurement container (independent power optional) Sensors for continuous analysis: • Chlorophyll • Conductivity • Nitrate • Oil in water • Oxygen • pH • SAC 254 • Solids concentration • Temperature • Turbidity Stationary measurement station with power supply and telephone connection As in the previous column. optional dedicated line ➔ Details of the sensors and instruments for process measurement technology and laboratory analysis can be found on the following pages ➔ For more information about DREL portable laboratories see page 38 SC 1000 Controller: a maximum of eight SC probes can be connected ➔ For more information see page 98 More information at www. Alkalinity. Copper. Silica. Phosphorus. Acidity. Sulphide. Chloride.co. Colour. Depending on its location.hach-lange. mains/independent power instruments. Suspended solids Iodine.com. Nitrite. reagents and accessories e. ready to use equipment. Calcium. com . integrated systems. www. HACH LANGE has created all that is needed for accurate results in the laboratory and in the field. quality control and accessories for more than 100 parameters. VIS and UV-VIS photometers Laboratory automation Complete measurement systems for continuous analysis ➔ See page 83 From small single parameter colorimeters to UV-VIS spectrophotometers ➔ See page 29 pH. with consumables. oxygen. HACH LANGE laboratory analysis—you can rely on us. redox Electrochemical measurement systems. conductivity. O2.16 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. completely equipped for a variety of applications ➔ See page 30 Well designed: That's what makes the HACH LANGE range of laboratory products so special. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.hach-lange. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES HACH LANGE laboratory analysis—from a single measurement to continuous analysis HACH LANGE’s product range for laboratory analysis is as extensive as water analysis itself. electrodes and accessories ➔ See page 18 Versatile Portable. Its trade mark is well designed. environmental laboratories. prepared standards with long-term calibration stability ➔ See page 73 Accessories Spectrophotometer/photometer accessories. sample preparation. From a fast screening test to standardcomparable analysis. in the laboratory or on site—the right measurement technology is available for every application Services ➔ On-site support ➔ Service + maintenance ➔ Disposal + recycling ➔ Website with downloads and e-shop ➔ Regular customer information ➔ Seminars + workshops ➔ Technical support WW DW PW Reagents ➔ For all key parameters from ammonium to zinc.17 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Measurement technology ➔ Single measurement or continuous analysis. with sample preparation and quality assurance 2 The HACH LANGE system for water analysis Reagents Visual tests. peripherals ➔ See page 78 . photometric reagents and standards for quality control ➔ See page 41 Turbidity USEPA and ISOcompatible measurement instruments. 18 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. manufacturers must be able to offer a wide range of products to satisfy all needs. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. Digital technology provides enormous flexibility and error-free handling. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES pH. This is where HACH LANGE. With the special RED ROD electrode technology. redox. both in the field and in the laboratory. by saving the calibration data in the intelligent electrodes. conductivity and ions (ISE) in industrial and research laboratories. electrodes and accessories. O2. with meters. www.g.com . conductivity and dissolved oxygen have proven their worth in many water analysis applications. with more than 50 years of experience and three innovative productlines. you can be sure of quick response times and long-term accuracy. a market leader.hach-lange. Good Laboratory Practice The METERLAB system is ideal for demanding applications requiring the determination of pH. 2 Proven technology for a wide range of applications SENSION meters and electrodes for pH. They have a rugged construction. Because these parameters are so widely used. with calibrationfree LDO sensors for measuring O . HQD/INTELLICAL products ➔ See page 19 SENSION products ➔ See page 24 METERLAB products ➔ See page 26 Digital data for confidence in field and laboratory HQD measuring instruments and INTELLICAL electrodes use digital technology to give you confidence in your results. INTELLICAL electrodes are available for all electrochemical parameters in a variety of configurations. easy handling and give reliable readings. conductivity. With a tried and tested range of electrodes. oxygen—every application in the laboratory and the field In the treatment of wastewater. e. pH is the basis for all analysis. drinking water and quality assurance. Conductivity and oxygen also play a key role in numerous applications. The varied METERLAB measuring instruments offer GLPcompliant solutions. conductivity and O2 more reliably and simply than ever before. The HQD meters can be integrated with accessories and electrodes. The special feature of HQD is the newly developed INTELLICAL electrodes: They store all relevant data in digital form in the electrode head.19 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 HQD—digital electrochemistry for reliable and accurate readings ➔ Excellent reliability and simple handling via automatic recognition of the electrodes (mix & match) WW DW PW 3 ➔ High flexibility due to the storage of calibration data in the electrodes Confidence in your pH. Mix + match for simple electrode handling So clever: INTELLICAL electrodes keep a record of their calibration data. HQD measures pH. The system benefits from handy practical accessories for use in the laboratory and in the field. Latest technology: the same input port for all electrodes—the HQD system recognises them automatically . conductivity and O2 readings HQD stands for High Quality Digital technology. This saves time and makes the process of changing electrodes even smoother. The electrodes are calibrated just once and are ready for immediate use with other HQD meters in the field. allowing the electrodes to be used in previously inaccessible locations. the shorter the time it takes for the red light to be emited www.hach-lange. excellent calibration stability and long instrument life.g. With digital data transfer. 15 or 30 m cable ➔ Quick response times and long instrument life of the INTELLICAL electrodes ➔ Outdoor versions available Standard conductivity electrode with 1 or 3 m cable Versatile: pH and conductivity electrodes INTELLICAL electrodes benefit from more than 50 years of experience.g. in each and every application. the outdoor versions function efficiently even under the most difficult conditions. LDO sensors do not contain a membrane. O2. 10. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW INTELLICAL electrodes for HQD— digital pH. cables can be as long as 30 m. Using LDO sensors saves time and money from day one. With a quick response time. The LDO sensor is based on an optical method: the more O2 there is in the sample. e. wells and bridges.com .20 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. conductivity 3 ➔ Calibration free LDO oxygen sensor with minimum maintenance required Outdoor pH electrode in stainless steel with 5. the sensor cap has to be replaced just once each year. also with a 30 m cable. e. and are therefore not susceptible to the risk of becoming blocked. conductivity and O2 ➔ Interference-free measurement. pH. Instead of frequent calibrations and changes of electrolyte. Photodiode Reference LED LED Ingeniously simple: O2 measurement without calibration The optical measurement principle of the LDO sensor (luminescent dissolved oxygen) has revolutionised O2 metering. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. www.uk.uk. error-free handling for single measurements or for complex tasks. The well organised menu structure is immediately understandable and user friendly. The illuminated display is clear and legible. rugged. maintenance-free CONDUCTIVITY Standard INTELLICAL 1m conductivity electrode. with 14-day free trial! . and HQD faithfully reminds you when the next calibration is due.electrochemistry/hach-lange. rugged. with interactive 3D demonstration. with liquid electrolyte filling Standard INTELLICAL pH electrode with gel electrolyte filling. All outdoor INTELLICAL electrodes/sensors are waterproof down to a depth of 30 metres for 24 hours. NO. Furthermore. keyword “HQD”. Need to calibrate? HQD lets you know! The appropriate calibration interval for the application is defined just once. with reinforced cable.co.21 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW 3 Clear display: visual and sound notification of stable readings GLP-compliant data management.hach-lange.hach-lange. also in the field: all the settings for each measurement are saved HQD uses plain English HQD has an intuitive user interface. with gel electrolyte electrolyte filling. Ensuring smooth. 15 m 4-pole graphite LDO (DISSOLVED OXYGEN) Standard INTELLICAL LDO sensor Outdoor INTELLICAL LDO sensor. ARTICLE pH DESCRIPTION Standard INTELLICAL pH electrode. you can also define the quality individually by entering specifications for the slope.com. including temperature sensor. NO. 3m PHC301-03 1m PHC101-01 3m PHC101-03 5m 15 m PHC101-05 PHC101-15 10 m 30 m PHC101-10 PHC101-30 CDC401-05 CDC401-15 10 m 30 m CDC401-10 CDC401-30 5m 15 m LDO101-05 LDO101-15 10 m 30 m LDO101-10 LDO101-30 More information at www. steel housing. HQD INTELLICAL electrodes/sensors All standard INTELLICAL electrodes/sensors are waterproof down to a depth of 3 metres for 24 hours. rugged 1m LDO101-01 3m LDO101-03 CDC401-01 3m CDC401-03 CABLE LENGTH ART. 4-pole graphite Outdoor INTELLICAL 5m conductivity electrode. with free downloads of brochures and user manuals HQD close-up at www. including temperature sensor. maintenance-free Outdoor INTELLICAL pH electrode.co. 1m PHC301-01 CABLE LENGTH ART. linear coefficient [numeric value] %/°C. 12 characters. total (GLP) Data storage 500 measured values. HQ40D only: simultaneous display of 2 parameters and temperature Power supply Mains power 115 V/250 V (power unit optional) 115 V/250 V. O2. Accuracy: ± 0.hach-lange. no compensation Calibration With automatic reminder of calibration Max. 5 positions. 5 positions (ISE) 0.1 Accuracy: ± 0. 4 points pH max. 12 sample and 20 user names. 2 decimal places Temperature compensation: non-linear (natural water in acc. battery powered 4 AA batteries or rechargeable batteries (battery charger necessary) Protection rating IP 67 for meter. pH or conductivity or O2 or or O2) ISE) Automatic air Automatic air pressure pressure compensation compensation ● ● ● ● ● Measuring range: 0. 4 points and control standard METERS HQ14D HQ30D flexi HQ40D multi 1 (conductivity) 1 (pH or conductivity 2 (per channel. 95 x 197 x 36 mm (H x W x D). automatic registration of number of samples (0-999) Measurement Manual. Accuracy: ± 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW HQD meters—technical data FEATURE Measurement channels Oxygen (LDO) Description HQ11D 1 (pH) Measuring range: 0. PC. 5 points ● ● ● ● Autoread Status display Electrode Interfaces ● ● ● ● Waterproof USB port for printer.0 mg/l.1 mV Ion Measuring range: electrode-dependent concentration Resolution: (selectable).01 oder 0. 240 x 160 pixel.1/0.5 % (1 µS/cm – 200 mS/cm) Measuring range: 0. non-linear (NaCl).1 mg/l.01/0. continuous. outdoor electrodes and connections Dimensions.1/0.001 ● Accuracy: ± 0.01 µS/cm – 200 mS/cm. 0. 0 – 200% Resolution: 0.500 mV ● Resolution: 0. measurement methods editable mode Display Backlit graphic display.1% saturation Accuracy: ± 1% of the measuring range pH Measuring range: 0 – 14 Resolution: (selectable) 0. manual or automatic data storage IDs For samples and users: alphanumeric. max. with DIN 38404/ EN ISO 7888).01 µS/cm – 400 mS/cm. temperature. detail. automatic switch-off in energy saving mode. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.00 – 20.01/0.5% (1 µS/cm – 400 mS/cm) pH max. Accuracy: ± 0.5% (1 µS/cm – 200 mS/cm) 1 point Measuring range: 0. interval. 323 g (without batteries) weight www.1 mV Conductivity Resolution: max.com .22 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. 4 points Conductivity 1 point Conductivity 1 point O2 1 point O2 1 point ISE max. with date and time display. max.001 Accuracy: ± 0.002 Temperature compensation: automatic Redox potential Measuring range: ± 1. USB memory stick Password ● ● ● ● protection Operating options Basic.01 µS/cm – 200 mS/cm. 3 m 205 CDC 401 outdoor. shockproof. keyword “HQD”. gel. Each HQ30D and HQ40D kit comes with a case and accessories. conductivity. conductivity. conductivity. with hand strap and neck strap Shockproof holder for the standard electrode. 10 m 115 PHC 101 outdoor. pH.00442) and user manuals . 15 m 330 LDO 101 outdoor. conductivity. 5 m 110 PHC 101 outdoor. memory chip with calibration data. liquid electrolyte.uk. O2. 1 m 103 PHC 101 standard.101301 consists of: – HQ30D meter – pH gel electrode. conductivity. contains the outdoor kit and 5 sample bottles (120 ml) For marking when submerged measurements are carried out. shockproof. contains the outdoor kit. X X X X X X 3 METER 40 30 14 11 HQ40D multi 2-channel meter for pH. 5828700 5829400 5825800 5835700 5828610 5819400 5813400 LZV568 LZV582 5811200 5826300 ➔ Buffer and standard solutions for HQD: see page 28 More information at www. www. 2 markers per colour For connecting a USB stick.101301 The starter kit HQ30D. two electrode holders for standard electrodes and 5 sample bottles (120 ml) For outdoor electrodes. conductivity. ELECTRODE/SENSOR 000 No electrode 101 PHC 101 standard. conductivity and O2 HQ14D 1-channel meter for conductivity HQ11D 1-channel meter for pH For example HQ30D. and sealing rings For mains powered operation of HQ11D/HQ14D/HQ30D flexi ART. pH.hach-lange. pH. 1 m 203 CDC 401 standard. with free downloads of brochure (DOC032. O2. 5 m 210 CDC 401 outdoor. 1 m 303 LDO 101 standard. pH. 1 m 153 PHC 301 standard.hach-lange.23 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 HQD—order information WW DW PW HQD starter kits—you choose the instrument to suit your needs: H Q X X D . conductivity. ISE and O2 HQ30D flexi 1-channel meter for pH. liquid electrolyte. 30 m 151 PHC 301 standard. 1 m cable – LDO sensor. with cable management for up to 3 metres of cable. 5 colours. 3 m 201 CDC 401 standard. practical plastic case. O2. O2. 1 m cable Each kit contains buffer and standard solutions. gel. 9 9 . 3 m 105 PHC 101 outdoor. lightweight.com. 128 MB capacity With USB connector Contains one sensor cap. pH. practical plastic case.99. keyboard or PC (only HQ40D) For saving data and transferring data between HQ40D and PC. O2.co. O2.52. printer. 5 m 310 LDO 101 outdoor. 30 m 301 LDO 101 standard. pH. NO. lightweight. pH. 3 m 305 LDO 101 outdoor.99. 15 m 130 PHC 101 outdoor. 15 m 230 CDC 401 outdoor. 30 m Accessories ARTICLE Outdoor kit Electrode holder Case (standard) Case (outdoor) Cable marker Electrode clips USB adapter USB memory stick Keyboard LDO sensor cap Power unit DESCRIPTION Shockproof plastic cover for outdoor use. pH. 10 m 215 CDC 401 outdoor. can be plugged into the plastic cover For standard electrodes. 5/pkg Coloured markers for identifying the different electrodes. 10 m 315 LDO 101 outdoor. hach-lange. together with the ingenious carrying case and the practical electrode holder on the meter. The right SENSION meter—for every parameter and every application METER PORTABLE METERS SENSION 1 Basic meter for routine pH analysis SENSION 2 pH meter for research and demanding tasks in the field SENSION 5 Precision analysis of conductivity. METERS SENSION 3 Electrochemical all-rounder for use in the field SENSION 4 pH and ISE configuration for demanding laboratory analysis SENSION 7 Precision analysis of conductivity. The large display. O2 BOD REDOX ISE ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● All SENSION meters are available in various configurations for use with different combinations of electrodes and accessories—the right solution for all measurements! More information at www. Practical and well designed All SENSION meters benefit from excellent precision and reliability in combination with intuitive operation.co.uk. but the five portable SENSION meters consistently satisfy every requirement. www. conductivity.com. Their rugged.24 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. watertight construction.com . integrated temperature compensation and useful automatic read and calibration functions ensure efficient analysis. Also portable in the field On-site analysis is very demanding.hach-lange.hach-lange. SENSION has proven its worth worldwide in numerous applications. user friendly operation Rapid stabilisation of measured values Rugged construction Proven worldwide—for pH. O2. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.52. keyword ”SENSION“ with free downloads of the brochure (DOC032.00599) as well as various data sheets and user manuals www. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW SENSION—outstanding electrochemical measurement technology ➔ ➔ ➔ ➔ ➔ 10 single and multi-parameter meters For use in the laboratory and in the field Simple. O2 and redox The SENSION family benefits from the combination of reliable measurement technology and integrated electrodes. ensure reliable results in the field. TDS and salinity SENSION 6 Electrochemical measurement of oxygen in aqueous solutions SENSION 156 Electrochemical all-rounder for use in the field LAB. especially the analysis of wastewater and drinking water in the laboratory and in the field. TDS and salinity SENSION 8 Electrochemical measurement of oxygen in aqueous solutions SENSION 378 Electrochemical multiple parameter meter for the laboratory pH COND. 5-pin connector. with docking station for mains powered operation and data documentation SENSION 5 with 4-pole conductivity measuring cell Portable meter for conductivity. refillable.000 µS/cm. gel dispensing function. membrane-covered 2-pole Clark sensor with temperature sensor. 5-pin connector Oxygen electrode. 1 m cable Combination pH electrode. autoread. with 3 m cable Docking station. batteries. for SENSION 2/5/6/156. 5-pin connector. with temperature sensor. measuring range pH 0-14. data storage.25 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW The docking station enables the SENSION meters to be connected to the mains power supply and to transfer data to a printer and a PC 3 SENSION meters and electrodes—order information SENSION METERS SENSION 1 with gel-filled pH electrode Portable meter for pH. batteries. gel dispensing function. calibration solution 1. with temperature sensor. autoread. 1 m cable. illuminated display. temperature sensor. with O2 electrode. case SENSION 2 with gel-filled pH electrode and docking station Description as 5172512. operation with batteries and rechargeable batteries. for operation with batteries and rechargeable batteries. data storage. refillable. with 2 replaceable gel-KCl cartridges. with temperature sensor. temperature range 0-100 °C. 1 m cable Gel-filled redox electrode with temperature sensor. case SENSION 2 with gel-filled pH electrode Portable meter for pH. temperature. temperature range 0-80 °C. with 2 replaceable gel-KCl cartridges. GLP capability. illuminated display. case SENSION 6 with oxygen electrode and docking station Description as 5185010. batteries. electrodes and accessories on request ART. Inputs: 5-pin and BNC socket. temperature. 5-pin connector. 5-pin connector. temperature range 0-80 °C. measuring range 0-80 °C. electrolyte. calibration and storage vessel. 1 m cable PLATINUM combination pH electrode with flat membrane for surfaces. measuring range pH 0-14. 3 m cable. autoread. BNC connector. 1 set of SINGLET buffer solutions (pH 4. 5-pin connector. inputs: 5-pin.01/7. NO. 1 m cable Gel-filled redox electrode. refillable internal electrolyte. inputs: 5-pin. description as 5197000.01/7. 2 spare membranes. 1 m cable Temperature sensor. ISE. GLP capability. measuring range 0-20 mg/l or 0-200%. with 15 m cable Conductivity cell. with docking station for mains powered operation and data documentation SENSION ELECTRODES AND ACCESSORIES Gel-filled combination pH electrode with temperature sensor. 1 m cable PLATINUM redox electrode with temperature sensor. with 3 m cable Oxygen electrode. with gel-filled combination pH electrode with temperature sensor. plastic stem.5 cm-1. salinity. gel dispensing function. 1 m cable Conductivity cell. 1 m cable PLATINUM combination pH electrode with temperature sensor. measuring range pH 0-14. temperature range 0-100 °C. 1 set of SINGLET buffer solutions (pH 4. GLP capability. without temperature sensor. 1 m cable. redox. NO. cell constant K= 0. calibration solution 1. case SENSION 5 with 4-pole conductivity measuring cell and docking station Description as 5180010. 230 V voltage supply. plastic stem. 5193500 5194000 5191000 5191500 5193900 5193700 5193200 5198000 5197000 5197003 5197015 5197500 5197503 5187502 . temperature.5 cm-1. plastic stem. with 2 replaceable gel-KCl cartridges. plastic stem. with 4-pole graphite conductivity measuring cell. temperature range 0-50 °C. with docking station for mains powered operation and data documentation SENSION 6 with oxygen electrode Portable meter for dissolved oxygen. data storage. cell constant K= 0. plastic stem. description as 5197000. redox. 5170011 5172512 5172515 5180010 5180014 5185010 5185014 ART. temperature range 0-80 °C. 4-pole. TDS. illuminated display.00). temperature range 0-80 °C. graphite. measuring range pH 0-14.000 µS/cm. batteries. 1 m cable Oxygen electrode. gel-filled combination pH electrode with temperature sensor. temperature range 0-100 °C. gel electrolyte filling.00). 5-pin-connector. inputs: 5-pin and BNC socket. description as 5197500. plastic stem. 1 m cable. 5-pin connector. with RS232C port for data documentation ➔ Buffers for the SENSION family: see page 28 ➔ Other SENSION meters. plastic stem. operation with batteries and rechargeable batteries. hach-lange. conductivity and ions (ISE). MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW METERLAB—electrochemistry for Good Laboratory Practice (GLP) METERLAB products provide excellent laboratory analysis of pH. PHM 220—the universal laboratory pH meter ION 450—latest technology for ion analysis Comprehensive choice of electrodes with RED ROD technology for quick response times and high precision METERLAB instruments—the key technical data DESCRIPTION Parameter Measuring range Temperature compensation CDM 210 Conductivity 0.000 to +23.000 to +23.co.000 pH PHM 250 * pH. electrodes and accessories complement the METERLAB products.00 pH PHM 220 pH -9. Your HACH LANGE contact will provide you with further information. keyword “METERLAB” with free downloads of brochures and user manuals www.com. AutoCal ➔ In some countries. ISE -9. O2.000 pH Calibration points GLP Date/time Measured values storage Calibration reminder Sample changer can be connected Special features Autoread 2 3 ● ● ● ● 9 ● ● ● ● 9 ● ● ● ● 5 ● ● ● ● Wide measuring range Simple operation GLP Multipoint calibration.com .000 to +23. ISE -9. With METERLAB.uk.00 to +23.000 pH ION 450 * PH. conductivity. More information at www. autoread. ISE -9.000 µS/cm Linear Non-linear 1 ● ● ● ● PHM 210 pH -9.00 pH PHM 240 * pH. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.00 to +23.hach-lange.001 to 2. Meters.hach-lange.26 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. GLP comes as standard. METERLAB gives reliable results through it's simple operation. these systems are distributed by specialised partners.01 µS/cm to 400 mS/cm Linear CDM 230 Conductivity 0. www. operation with sampler Versatile * Free input of calibration standards All: RS232C interface. 000 ppm 0 to 80°C Porous pin 0 to 50°C Platinum ring sensor element Interference ions OHSalt bridge solution 3 M KCl + saturated AgCl pH range 5-7 ➔ Buffers for the METERLAB family: see next page ➔ More about METERLAB meters. Cell constant Number of poles Maximum temperature Minimum immersion depth Special features CONDUCTIVITY General purpose CDC566T E61M010 1. Reference system Measuring range Temperature range Min.0 cm-1 4 80 °C 3 mm CONDUCTIVITY Strong acids/ bases CDC861T E16M016 1.27 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Selection of METERLAB pH.85 cm-1 2 100 °C 14 mm CONDUCTIVITY Pure water CDC511T E61M009 1. redox and fluoride electrodes WW DW PW 3 PARAMETER Applications Type Art.0 cm-1 4 80 °C 35 mm CONDUCTIVITY General purpose CDC641T B15B001 0.1 cm-1 2 100 °C 26 mm The SAM7 sample station is a combined magnetic stirrer and electrode holder—for stable and reproducible stirring conditions Temperature sensor Temperature sensor Temperature sensor Temperature sensor platinised platinised . no. Sample depth Liquid junction Special features pH General purpose PHC2001 E16M313 RED ROD 0-12 pH -10 to 100 °C 18 mm Porous pin pH General purpose PHC2085 E16M501 RED ROD 0-12 pH -10 to 100 °C 14 mm Porous pin Temperature sensor pH Alkaline samples PHC2011 E16M317 RED ROD 0-14 pH 0 to 100 °C 18 mm Porous pin pH High KCl outflow PHC2701 E16M323 RED ROD 0-12 pH -10 to 100 °C 18 mm Ring-shaped pH General purpose gel-filled PHC3105 E16M308 Ag/Cl 2-12 pH 0 to 60 °C 18 mm Open Rugged REDOX General purpose MC3051Pt E31m003 Ag/Cl F- ISEC301F E41M017 Ag/Cl recommended 5x107–100 M 0.0 cm-1 4 100 °C 35 mm CONDUCTIVITY Low conductivity CDC267-9 E61M011 0. no.01-20. electrodes and accessories on request Selection of METERLAB conductivity electrodes PARAMETER Applications Type Art. com .000 ± 10 µS/cm as NaCl 1000 mg/l 1.1 D 12.1 M KS 920 1.88 mS/cm KCl 0.01 Blue 20/pcs 2770220 ➔ Additional buffers and standards on request Conductivity standard solutions DESCRIPTION DESCRIPTION QUANTITY ART.47 mg/l 180 ± 10 µS/cm as NaCl 491 mg/l 1.23 Technical.001 M Other Electrode rinse solution Electrode rinse solution 500 ml 500 ml 500 ml 500 ml 100 ml 100 ml 100 ml 100 ml S51M001 S51M002 S51M003 S51M004 2307542 1440042 210542 2307442 500 ml 500 ml 500 ml C20C250 C20C270 C20C280 20/pcs 500 ml 2770320 2756549 *Buffer traceable to standard reference material produced by NIST. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.5% KCl 0. guaranteed shelf life.00 pH 4.00 Colourless 500 ml 1222149 pH 1.679 500 ml S11M001 pH 4.990 ± 20 µS/cm as NaCl 10.85 mS/cm ± 0.01 Red 500 ml 2283449 pH 7.000 ± 50 µS/cm as NaCl Molar KCl solutions KS 910 12.408 µS/cm ± 0. NO. Certified pH standards that conform to IUPAC Supplied in airtight sealed tin. with colour coding.012 500 ml S11M007 Quality buffer solutions Ready to use.246 mg/l 18. with and without colour coding* pH 4. with colour coding* pH 4.01 and Red + Yellow 2 x 10/pcs 2769920 pH 7.01 M KS 930 146.01 Red 50/pcs 2226966 250/pcs 2226964 pH 7. tolerance ± 0.010 pH (25 °C) pH 1. Standards with certificate Supplied in airtight sealed tin.09 Technical.28 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. with COFRAC certificate. traceable to standard reference material produced by NIST KCl 1 D 111.00 Blue 50/pcs 2227166 250/pcs 2227164 SINGLET buffer solutions In individual pouches. NO. METERLAB pH buffer solutions DESCRIPTION DESCRIPTION QUANTITY ART.005 500 ml S11M002 pH 7.01 Red 20/pcs 2770020 pH 7. 500 ml S11M009 conforms to (DIN 19267) pH 4.015 µS/cm ± 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW pH buffer and conductivity standards for HQD. traceable to standard reference material produced by NIST.00 and Yellow + Blue 2 x 10/pcs 2769820 pH 10.01 Blue 500 ml 2283649 pH 4.000 500 ml S11M004 pH 10. 500 ml S11M011 conforms to (DIN 19267) Buffer/Powder Pillow Individually sealed. guaranteed shelf life.02 pH (25 °C) www.413 mS/cm KCl 0. hermetically sealed.5% NaCl solutions 85.01 D 1.hach-lange.00 Yellow 50/pcs 2227066 250/pcs 2227064 pH 10. 25 ml each* pH 7.3 mS/cm ± 0.5% NaCl 0.05% 1. with certificate.00 Yellow 500 ml 2283549 pH 10. tolerance ± 0.00 Yellow 20/pcs 2770120 pH 10.9 µS/cm KCl 0. O2.01 pH 4.00 Colourless 500 ml 1222249 pH 10.01 Colourless 500 ml 1222349 pH 7.65 Technical.35% KCl 0. each sufficient for 50 ml fresh solution. SENSION. 500 ml S11M010 conforms to (DIN 19267) pH 9. 2 x 15. All the photometers are preprogrammed for ready-to-use HACH LANGE reagents.5 kg ➔ Thermostats.1 x 3. 35 UV-VIS 190-1. 32 VIS 1-4 fixed wavelengths Filter Max.100 nm Spectral Wavelength/Time ~ 230 ● ● ● ● Max. 30 VIS 1 fixed wavelength Filter 1-2 ● DR 800 COLORIMETERS p.6 cm 450 g (without batteries) 22 x 13. 34 VIS 340-900 nm Spectral ~ 220 ● ● ● XION p.000 ● Max.7 x 4. 1.29 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Outstanding photometers for water analysis and quality control The HACH LANGE range of photometers are as varied as the situations in which water analysis and quality control are required. 90 ● DR 2800 p. 37 VIS 340-900 nm Spectral Wavelength/Time ~ 100 ● DR 5000 p. HACH LANGE has the right instrument with the right performance spectrum for every application.5 x 16. 4 POCKET colorimeters DR 800 colorimeters DR 2800 XION DR 5000 The Who’s Who of HACH LANGE photometers FUNCTIONS See page Wavelength range: visible light (VIS) and UV light Optical system: photometer type Scan Pre-programmed tests Cuvette tests. 1. automatically reliable PERMACHEM Powder Pillows. 500 ● Max. printers and other accessories for the photometers: see page 78 ➔ Reagents and quality assurance for the photometers: see page 66 ➔ Laboratory photometers for analysis in chapter 4. 50 Max.5 x 37 cm 9 kg 45 x 20 x 50 cm 15.2 cm 230 g (without batteries) 8.7 x 33.7 x 23. ACCUVAC. laboratory automation: see page 83 .000 ● ● ● ● ● ● IP 67 ● ● RS232 IP 67 ● ● USB IP 42 ● ● RS232 IP 31 USB IP 31 6.2 cm 4 kg (without batteries) 41. reagent solutions User methods programmable Measured value storage capacity GLP compliant documentation Sector-specific supplementary software Cuvette carousel Flow-through function (Sipper) Display with touchscreen Ports Protection rating Mains-independent operation Available in portable laboratory Dimensions (W x H x D) Weight POCKET COLORIMETERS p. 10 Max. these lightweights (230 g) can cope with all situations. single parameter instruments Easy operation Small enough for almost any pocket Reliable results without a mains connection Rugged construction yet lightweight Now better than ever for field-testing Each POCKET Colorimeter II is programmed for one or two parameters. The tried and tested colorimeters have been enhanced to make them even more convenient to use. even under the most difficult conditions. gives reliable results anywhere.com . and now offers an ideal combination of robust technology and intuitive handling. All models are supplied in a fully equipped carrying case.hach-lange. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW POCKET Colorimeter II—30 mini-meters for field testing ➔ ➔ ➔ ➔ ➔ More than 30 flexible. Benefits – Simple: all functions are available via only four keys – Power: battery operation for a maximum of 2.000 tests – Clear readings: even under difficult conditions. complete with carrying case Strength of in the design With their rugged construction. It is pocket sized and together with the practical HACH tests. www. O2. thanks to lighting and large figures on the display – Waterproof to IP 67: for watertight results! Pocket sized and rugged colorimeters.30 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. 0 (Co) 0. keyword “POCKET” together with the desired parameter from the above list.0 –100 2.0/0.5/0.uk.0 0.02-0.7 0.0 0.80 0.75 0.04 – 5.10 – 8.005 – 0.2 –10.com.7 0.0 0 – 2.01– 0.10 –10 (Cl2)/6.8 0.01–1. www.5 Absorbance 0 – 2.0 (Ni)/0.5 Absorbance 0 – 2.04 – 4.5 (Cl2)/0.5 Absorbance 0 – 2.0 – 70 0.15 0.31 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Mini-meters for field testing 4 POCKET Colorimeter II in carrying case.5 Absorbance 0 – 2.00608) and User Manual (DOC022.05 – 4.5 Absorbance METHOD Aluminon Salicylate DPD DPD DPD/phenol red DPD DPD.0 –125 (PO43-) 1. cuvettes and operating instructions METER PARAMETER Aluminium Ammonium Bromine Brom Chlorine (free and total and pH) Chlorine (free and total) Chlorine dioxide Chromium (VI) Copper Fluoride Iron Iron Lead Manganese Manganese Molybdate Monochloramine/ ammonium-free Nickel and cobalt Nitrate (NO3-) Oxygen Ozone Phosphate (ortho/total) (PO43-) Phosphonate with UV lamp Silica Sulphate Zinc Wavelength Wavelength Wavelength Wavelength Wavelength Wavelength Wavelength Wavelength Wavelength 420 nm 450 nm 476 nm 500 nm 528 nm 550 nm 580 nm 600 nm 655 nm MEASURING RANGE/mg/l 0. 5870025 5870040 5870021 5870001 5870012 5870000 5870051 5870017 5870019 5870005 5870016 5870022 5870021 5870018 5870015 5870010 5870026 5870020 5870002 5870003 5870004 5870006 5870008 5870034 5870029 5870009 5870042 5870045 5870047 5870050 5870052 5870055 5870058 5870060 5870065 Also for immunoassays ➔ All tests for POCKET Colorimeter II: see page 54 More information at www.2 –10.0/0.0 0.02 – 3. complete with reagents.5/1. glycine Diphenylcarbazide Bicinchoninate SPADNS reagent TPTZ FerroVer Column extraction PAN Periodate oxidation Ternary complex Indophenol PAN Cd reduction HRDO Indigo trisulphonate PhosVer3 PhosVer3/UV Molybdate Barium chloride Zincon DETERMINATIONS 100 100 20 100/50 100/100 and100 (pH) 50/50 100 100 100 50 50 100 20 100 100 100 100/50 100 100 50 50 100 100 100 100 100 ART.01– 0.co.02 – 5.2 – 2. NO.5 Absorbance 0 – 2.25/0.01–1.hach-lange.52.0 0.5 Absorbance 0 – 2.0 0.5 (pH) 0.02 – 2.02 – 2.5 mg/l 0.02 – 3.005 – 0.2 – 20 0.5 Absorbance 0 – 2.05 – 5.4 – 30 0.02 – 3.52.0 0. with free downloads of brochure (DOC062.0 0.01– 0.1–12.01– 0.0 0.hach-lange.15 0.0 – 8.006) .01– 0.5 Absorbance 0 – 2.0 0.7 0.1– 2.01 – 0. 50 or 90 water analysis tests. using the latest technology with a rugged construction. They provide simple handling. drinking water and process water analysis.com . CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. Reliable Suitable for use.hach-lange. O2. 50 or 90 tests The DR 800 colorimeters are designed for use in the field. The large graphic display shows the results and the data storage and data transfer features enable the results to be easily documented. fast results in wastewater. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW DR 800 series—compact colorimeters for 20.32 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. The three models are configured for approximately 20. Key benefits Advantages of the DR 800 are: – Automatic wavelength selection for simple operation – Capable of operating for long periods without being connected to the mains – User methods can be programmed – Configured for immediate use DR 800 also available with soft sided case www. Versatile The DR 800 models are preprogrammed for different numbers of tests: – DR 820: 20 tests – DR 850: 50 tests – DR 890: 90 tests All three DR 800s work best in combination with the practical HACH tests for reliable. you choose the right instrument for your analysis. anywhere! The dustproof and waterproof (IP 67) construction of the DR 800 models guarantees reliable water analysis even under the most difficult conditions. 33 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW 4 DR 800 with portable water laboratory: see page 38 Technical data for DR 800 series Model Art. no. Display Optical system Wavelength range DR 820 DR 850 4844000 4845000 Large graphic display Very stable, energy-saving LED technology 520 nm 520 nm 610 nm DR 890 4847000 DR 800 parameter list PARAMETER Aluminium Ammonium Boron Bromine Chloramine (mono) Chlorine (free and total) Chlorine dioxide Chromium (VI and total) COD Colour (Pt-Co units) Copper Cyanide Cyanuric acid DEHA Detergents (anionic) Fluoride Hardness Hydrazine Immunoassay Iron Manganese Molybdat Nickel Nitrate Nitrite Nitrogen (Kjeldahl) Nitrogen (total) (TNb) Organic acids Oxygen Ozone pH (photometric) Phosphate (ortho) Phosphate (total) Phosphonate Silicic acid/Silicate Sulphate Sulphide Suspended solids (TSS) Tannin + lignin TOC Turbidity (FAU) Zinc DR 820 ● DR 850 ● ● DR 890 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Spectral band width Wavelength selection Measurement methods Date/time Data storage Interface Dimensions Weight Protection class Test marks 10 nm 10 nm Automatic when method is selected Pre-programmed HACH methods Absorbance and transmittance User methods can be programmed Built-in real-time clock For up to 99 measured values RS232C via infrared adapter 23.6 cm x 8.7 cm x 4.7 cm 450 g (without batteries) IP 67, dustproof and waterproof CE, GS 420 nm 520 nm 560 nm 610 nm 10 nm ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● DR 800 accessories DESCRIPTION Measurement cuvettes (10/20/25 ml graduations; 1 inch diameter), 6/pkg Soft sided carrying case for DR 800 models Rugged carrying case for DR 800 models Rugged carrying case for DR 800 laboratories for colorimeter, accessories and reagents Immunoassay adapter, 12 mm diameter Data transfer adapter (IR/RS232C) including cable HACH LINK software for data transfer from HACH photometers to a PC through an interface ➔ DR 800 in portable water laboratory: see page 38 ➔ All tests for DR 800: see page 54 ART. NO. 2401906 2722000 4942500 4943000 4846700 4849000 4966500 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● More information at www.hach-lange.co.uk, www.hach-lange.com, keyword “DR 800”, with free download of Short User Manual (BDA437) 34 LABORATORY ANALYSIS 2_OVERVIEW 3_pH, O2, CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD, MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Outstanding variety of methods—for all HACH LANGE tests The unique HACH LANGE range of reagents can now be used with the DR 2800 spectrophotometer. All PERMACHEMs, ACCUVACs and cuvette tests are preprogrammed and freely selectable. In addition, the DR 5000 UV-VIS spectrophotometer now covers an even more extensive range of applications, including programmed user methods in the UV range, scans, special drinking water and brewery analysis. For all HACH LANGE tests: DR 2800 VIS Spectrophotometer— measurements without even pressing a button Simple and very precise: automatic test identification and outlier elimination Time-saving and innovative: evaluation in the open cell compartment Intuitive operation: touchscreen with easily understandable menus Wastewater CUVETTE TEST Results automatically saved 50 mm cells ACCUVAC 1-inch cells Easy-to-handle innovative and reliable cuvette tests, comparable to reference methods USB memory stick PERMACHEM Powder Pillows www.hach-lange.com 35 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Even more versatile: DR 5000 UV-VIS Spectrophotometer, e.g. for scans and all HACH LANGE tests; freely programmable WW DW PW 4 Drinking water, cooling water, boiler water ACCUVAC PERMACHEM Results saved manually Automatic sipper module cm Multi cell holder inch DR 2800 VIS: rugged instrument for use in the laboratory and in the field The DR 2800’s reliable optical system ensures accurate results. Each wavelength is freely selectable, and the instrument’s memory can accommodate 50 user methods and up to 500 measured values alongside the 200 preprogrammed tests. The variable cell sizes enable readings to be taken across wide measuring ranges, from trace analysis to high concentrations in electroplating baths. Easily understandable menus and the large touchscreen helps prevent errors. DR 5000 UV-VIS: demanding water analysis in the laboratory The DR 5000 UV-VIS Spectrophotometer culminates from the experience of the manufacturers HACH and LANGE: high quality optics, fast scans and user friendly operation are essential in any demanding water laboratory. The key benefits include the versatility of the DR 5000. This is reflected in the multi cell holder, the cell modules, the high precision optics and more than 200 factory-installed HACH LANGE methods. ➔ For more information about the tests for the DR 2800 and DR 5000 see page 54 ➔ Technical data: see next page More information at www.hach-lange.co.uk, www.hach-lange.com, keyword “DR 2800” or “DR 5000”, with free downloads of brochures (DR 2800: DOC032.52.00437; DR 5000: DOC032.52.00432) and User Manuals (DR 2800: DOC022.52.00720; DR 5000: DOC022.52.00654) 36 LABORATORY ANALYSIS 2_OVERVIEW 3_pH, O2, CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD, MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Facts and figures about the DR 2800 and DR 5000 DR 5000 UV-VIS Spectrophotometer with high precision optics Application software for drinking water analysis: LZV571 Application software for brewery analysis conforms with MEBAK, LZV570 Technical data DR 2800 DR 5000 VIS Spectrophotometer UV-VIS Spectrophotometer with multi cell holder LPV422.99.00001 LPV408.99.00001 To compensate for lamp ageing and power fluctuations Absorbance (± 3A), transmittance (%), concentration 340–900 nm 190–1,100 nm ± 1.5 nm ± 1 nm at 200–900 nm 0.1 nm 0.1 nm 1 nm 0.1 nm 900 nm/min in 1 nm steps 5 nm 2 nm 5 mA at 0.0–0.5 A; 1% at 0.5–2.0 A < 0.5% at 2 A; 1% at > 2 A < 0.1% absorbance at 340 nm < 0.05% absorbance at 340 nm Automatic identification of LANGE Cuvette Tests, including 10 measurements per rotation for outlier elimination Round cuvettes: 1 inch, 13 mm Multi cell holder for round Rectangular cells: 10 mm, 50 mm, 1 inch Round cuvettes: 30 mm, 1 inch Rectangular cells: 10 mm, 20 mm, 50 mm, 1 inch Manual flow-through module, Automatic sipper module for without sipper motor (Art. no. 5940400) flow-through cells (Art. no. LZV485) Changer module for a maximum of seven rectangular cells, 10 mm (Art. no. A23620) Peltier module 15–50 °C, for rectangular cells, 10 mm (Art. no. LZV513) Backlit, high-resolution LCD (320 x 240 pixel, touchscreen) 500 measured values 1,000 measured values, 20 wavelength scans, 20 time scans 1 USB port for PC, 1 USB port for printer, 1 USB port for PC, 2 USB ports for printer, keyboard, USB memory stick keyboard, USB memory stick IP 42 IP 31 100–120 V; 200–240 V; 50/60 Hz; automatic switchover Optional (Art. no. LZV551) 13 x 33 x 22 cm, 4.1/4.4 kg without/with battery 20 x 50 x 45 cm; 15.5 kg Article number Reference beam technology Operating modes Wavelength range Wavelength accuracy Wavelength reproducibility Wavelength resolution Scan rate Spectral band width Photometric accuracy Photometric linearity Stray light IBR Integrated Barcode Reader Cell holders Flow-through measurement Changer Cell temperature control Display Data storage Ports Protection rating Power requirement Li ion battery Dimensions (H x D x W), weight For information about additional software, cells, peripherals and other accessories for the DR 2800 and DR 5000 see page 78; complete accessories list in eShop under www.hach-lange.co.uk, www.hach-lange.com, keyword ”LPV408“ for DR 5000 or “LPV422” for DR 2800 www.hach-lange.com 37 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 For accurate analysis: XION spectrophotometer ➔ Manages and exports data ➔ Variable wavelength scans ➔ Time dependent measurements with auto function WW DW PW 4 ➔ 100 LANGE tests available ➔ Same as LICO 400 for measuring the colour of clear liquids Benefit: working with open cuvette compartment—with XION LOCK IN technology XION—Data management for water analysis The database enables the data from 2,500 measurements to be stored and evaluated without a PC. The data can be exported through the serial interface to a PC or LIMS, or can be copied. Thanks to the data handset, the instrument data can be updated at any time by telephone. Automatic outlier elimination ensures maximum reliability in the results of LANGE cuvette tests. LICO 400—Standard colour determination With 24 international colour scales, e.g. Hazen (Pt-Co), Gardner, Saybolt and ASTM D 1500, the LICO 400 is the ideal colorimeter. It is suitable for measuring coloured transparent solutions. It also conforms to Pharm. Eur. and US-Pharm. All colour scales are easliy readable with one measurement in just one cuvette. LZV537 test filter kit. Secondary standards for ISO-compliant self-monitoring: ➔ See page 80 XION spectrophotometer/LICO 400 colorimeter Model no. Type Wavelength range Wavelength accuracy Operating modes Scan Zeroing Cuvette compartments Storage LPV385 (XION), LMV184 (LICO 400) Spectrophotometer with reference beam path 340–900 nm ± 2 nm Concentration, absorbance, transmittance Wavelength scan, time scan Automatic Separate, for LANGE round or rectangular cuvettes up to 10 x 50 mm For more than 2,500 measured values; for user methods LOCK IN technology Large display IBR technology* LANGE cuvette tests* LANGE NET* To eliminate stray light For measured values, graphs and tables With tenfold measurement of round cuvettes, including outlier elimination Completely pre-programmed Integrated data handset for updating data by telephone Interfaces 1 serial and 1 parallel * XION spectrophotometer only ➔ LANGE tests for XION: see page 54-65, Accessories: see page 77-82 More information at www.hach-lange.co.uk, www.hach-lange.com, keyword „XION“ or „LICO 400“, with free downloads of brochures (XION: DOC032.52.00007; LICO: DOC032.52.00534) and User Manuals (XION: BDA 447, LICO: DOC022.52.00524) The integrated work surface enables analysis to be carried out safely and easily at any location. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.hach-lange. we have to be able to carry out analysis anywhere. The portable laboratories contain everything needed to ensure that accurate measurements can be taken. digital titrators and electrochemical methods DREL and CEL comprehensive laboratories can deal with all kinds of water: – Drinking water – Wastewater – Cooling and boiler water – Process water.com.38 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. The ultimate in versatility—the DREL 2800 analysis case with tests for more than 20 parameters for professional water analysis.hach-lange.hach-lange. O2. www. there is the need for efficient measurement technology. practical accessories and ready-to-use reagents. For more information about the portable complete laboratories.com . also in other configurations. and many more Anyone can use the instruments without any difficulty. Photometers.uk. keyword “DREL” or “CEL” www. Even in the field. They are configured for different ranges of parameters. The colorimeters of the DR 800 family are at included in the CEL analysis case. go to www.co. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW DREL and CEL portable field laboratories ➔ ➔ ➔ ➔ Configured for a variety of applications Choice of parameters Versatile and rugged Simple operation with ready-to-use reagents Compact and comprehensive laboratories Today. 1-20. ortho Phosphorus.0 mg/l 0.05-4.9 mS/cm 6-210 µg/l 10-160 mg/l 100-4. in two sturdy cases MEASURING RANGE 10-4.50 mg/l 100-4.02-2. DREL 2800 COMPLETE LABORATORY For professional water analysis On request Complete with DR 2800 spectrophotometer.0 mg/l P P 100 100 1-100 mg/l 2.0 mg/l 1-500 Pt-Co units 0. oxygen probe with electrodes.00 mg/l 0.00 mg/l 0.02-2.000 mg/l 0. manuals. accessories.0-70 mg/l 5.50 mg/l 0.60 mg/l 3-200 mg/l 4.30-30.000 mg/l BART tests** 0. SENSION 1 pH meter.50 mg/l P P 100 100 Silica Silica Sulphate Sulphide Sulphite Suspended solids Zinc 0. in two sturdy cases MEASURING METHOD* DETERART. D = Titrimetric with digital titrator. NO. total Chromium (VI) Colour Conductivity Copper Hardness.00 mg/l 0.02-3. Contents PARAMETER Acidity Alkalinity Ammonium (as N) Bacteria Bromine Calcium Calcium Chloride Chlorine.0 mg/l 0.0 mg/l 0.300 mg/l 4-9 P D P P P P P E 100 100 100 100 100 100 100 25 100 100 100 100 100 100 100 50 P P P P P E P P D 100 100 100 0.000 mg/l 10-160 mg/l 10-10. optional pH meter.000 mg/l D 100 2272800 10-4. RANGE MINATIONS 10-4.00 mg/l 0.002-1 mg/l 0-14 pH 0-125 mg/l 0. SENSION 5 conductivity meter. no. total Manganese Molybdate Nitrate (as N) Nitrite Oxygen. digital titrator.0001-199. total Sequestrants 4 D B P 2271900 2434809 2105669 D P P P P P E P D 100 100 100 100 100 2288000 1407099 2105569 1406499 2105669 Reagentfree Reagentfree 2603300 2448100 2448000 2105769 2430000 2604100 2107569 2501025 Reagentfree 2429700 2244100 1457799 2434501 2284799 244932 2459300 2244300 0.2-40 mg/l 2-150 mg/l 0.03-5.0-800 µg/l 5.02-1. conductivity probe. digital titrator. free Chlorine.01-0.50 mg/l 10-8.70 mg/l P 1-500 Pt-Co units P E 0. dissolved pH Phosphonates Phosphorus.14-30mg/l 0-40 mg/l Na4EDTA METHOD* DETERMINATIONS 100 3 each 100 ART.00 mg/l 0. accessories.0-750 mg/l P P P P 100 100 100 2429600 2106769 2244500 Reagentfree D P P 100 100 2272300 Reagentfree 2429300 * Method: P = Photometric.02-2.002-0.00 mg/l 0. sulphate-reducing and slime-forming bacteria ➔ For more information about the tests for the DR 2800 and DR 5000 see pp 34-36 ➔ For more information about the DR 800 colorimeters and the DR 2800 photometer see pages 32 and 34 ➔ More reagents for the DR 800 and DR 2800: see pp 46-65 .07-7. NO.0-400 mg/l 5-750 mg/l 0. three determinations of iron bacteria. reagents (see list below).2-20.03-3.02-2.03-5.00 mg/l 0.00 mg/l P D D D P P 100 100 100 100 100 100 100 See Chlorine 2447500 2447200 2288000 2105569 2105669 1271099 Reagentfree Reagentfree 2105869 2272000 See Chlorine 2105769 2430000 2106169 2107169 Reagentfree 2106069 2459000 DW PW Art. B = Biological ** BART tests: Per test. optional turbidimeter.000 mg/l 0.02-3.000 mg/l 0. E = Electrochemical.6-220 °dH 10-4.01-0.000 mg/l 0.02-2.39 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW CEL and DREL complete laboratories—a selection CEL 890 COMPLETE LABORATORY For cooling and boiler water 2688400 Complete with DR 890 colorimeter.50 mg/l P 100 2668000 0.04-4. reagents (see list below).0 mg/l 0. BARTs.000 mg/l D 100 2271900 0.02-2. manuals.04-5. total Iodine Iron. This can all be achieved under difficult conditions. The fully equipped portable laboratory contains an incubator. 30 tubes brilliant green bile broth. From sterile working practices to the final measured value. pseudomonas. 30 sterile inoculating loops. nutrient media salt for 25 5-tube MPN tests. MEL microbiology environmental laboratories DESCRIPTION/ ART. coli. sulphide. 2619101 MEL PA/ 2569600 Presence/ Absence (yes/no) Most Probable Number 2580000 2438800 1403599 2580200 MEL MPN/ 2569800 MEL 850/ 2688800 E. pH.com . 50 sampling bags Chlorine reagent kit. coli. pH E. coli. nitrate. additional: chlorine. temperature. (yes/no) nitrite. accessories on request www. with 50 disposable P/A tests Nutrient broth with MUG. NO. free and total chlorine Nitrate reagent kit MPN reagent kit. total dissolved solids. free and total. These systems are suitable for all types of water. chlorine. total bacterial count E.o-phosphate. 25 sampling bags MEL 850 reagent kit Chlorine reagent kit. total coliforms Presence/ Ammonium. turbidity 2691100 2438800 ➔ Microbiological tests: see page 70. total dissolved solids. total bacterial count TYPE OF DETERMINATION Membrane filtration REAGENT KITS MF reagent kit A. with 200 ready-mounted funnels with Membrane filters and petri dishes for filtration station II 200 m-Coliblue24 broth. Yes/No answers or exact bacterial counts Both can be provided by the MEL laboratory. which can run on mains or battery power. O2. free and total chlorine KIT ART. MEL MF 2569700 FOR THE DETERMINATION OF E. coli. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. with 135 tubes LT/MUG nutrient solution.hach-lange. total coliforms optional: faecal coliforms. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Portable microbiological testing anywhere ➔ Comprehensive MEL portable laboratories ➔ Wide range of parameters ➔ Prepared tests ➔ Simple to use ➔ Accurate results The microbiological laboratory with carrying case A variety of microbiological parameters can be measured in the field. Absence colour. 25 sterile 11-ml pipettes. total coliforms. total coliforms optional: faecal coliforms. NO.40 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. 200 sampling bags MEL P/A nutrient media kit. nitrate. e. colour disks Simple photometry. e. Simple photometry— Powder Pillows and ACCUVAC Ideal for photometric measurements under difficult conditions: – Powder Pillows are individually packaged reagents with a shelf life of several years – ACCUVACs: vacuum-sealed glass ampules containing measured amounts of reagents. Visual tests. proven tests. ACCUVAC Cuvette test. Ammonium .g. Powder Pillows. e. e. HACH LANGE offers simple.41 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 The unique HACH LANGE spectrum of photometric and visual tests The HACH LANGE range of products for visual and photometric water analysis is unique: with tests for more than 70 parameters in all relevant measuring ranges. 5 Visually evaluated tests— portable. Their quality is demonstrated by the fact that for the first time a cuvette test—ISO COD—has been accepted as a reference method.g. – Test strips – Colour cubes and disks – Drop count tests – Digital titrator Affordable analysis for semi-quantitative results.g. from simple screening to reliable monitoring of threshold values—and always easy to use! In combination with a HACH LANGE photometer or visual evaluation kit. monitoring consent limits as an equivalent alternative to time-consuming reference methods. fast and affordable For fast results in the field. e. without complex instruments. the tests allow analysis for each and every photometric application. with no manual dispensing Outstanding precision and handling—cuvette tests Cuvette analysis can satify the most demanding tasks.g. They guarantee simple handling.g. In the field they are ideal for monitoring swimming baths or surface water. Colour disks and cubes Colour comparison tests enable analysis to be carried out economically. test strips provide a quick indication of the measuring range or any problems. on-site process and water checks. They contain an exactly portioned amount of reagent.com . O2. and read off the concentration at the point where the colour match is found. Both test variants are available for a large number of parameters and can be evaluated visually or with HACH LANGE photometers. Simply add a Powder Pillow or ACCUVAC to the sample. e. Powder Pillows and ACCUVAC Photometric analysis of drinking water and wastewater can also be carried out under the most difficult conditions using Powder Pillows and ACCUVACs.g. have a long shelf life. and give reliable measurement results at an attractive price. the colour disk is more accurate than the colour cube.42 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Simple to use—visual tests. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.hach-lange. For order information see ➔ List of reagents on page 47 www. Since the colour scale is continuous. For order information see ➔ List of reagents on page 47 Test strips Simple to handle test strips give an overview of the water quality in just a few seconds. compare the resulting colour with the colour disk. In the laboratory. the measuring cuvette is then ready for the next analysis. 77 DW PW 5 Powder Pillows—more than 100 low-price methods Powder Pillows are available for a large number of parameters and measuring ranges—there are more than 100 tests in all. which contain sufficient reagent for a large number of analyses and are simple to replace. The digital titrator displays the result directly for many parameters. ACCUVAC tests are especially suitable for analysing drinking water and surface water for volatile substances such as chlorine and ozone.43 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW Drop count tests + digital titrator Drop count tests are simple titrations: the reagent is dripped into the sample until a colour change occurs. For order information see ➔ List of reagents on page 80 . For order information see ➔ List of reagents on page 47 ➔ Digital titrator. whilst ensuring thorough mixing. and for analysis in the field. For order information see ➔ List of reagents on page 54 ACCUVACs—the ingenious solution for 25 parameters The secret of the ACCUVAC is the vacuum in the sealed glass cuvette containing a portioned amount of reagent. the reagents have a shelf life of many years. After thorough rinsing. Hermetically sealed in aluminium foil pillows. page 52-53. attractively priced alternative. with a colour disk. then breaking it by applying moderate pressure. the result is read from a table. It contains enough reagent for 250 chlorine tests (free or total chlorine). the SWIFTEST is ideal for laboratories with a high sample throughput. The evaluation can be carried out visually. For order information see ➔ List of reagents on page 54 The right amount of DPD with the SWIFTEST The SWIFTEST is a powder dispenser that releases the correct amount of DPD (diethyl-p-phenylenediamine) at the press of a button. It uses parameter specific reagent cartridges. The resulting colour is measured visually or photometrically.g. As a practical. On the basis of the drop count. The vacuum draws the sample into the cuvette. or with a HACH LANGE photometer. e. The reagent is simply poured into the measuring cuvette together with the sample. The test is carried out by immersing the tip of the ACCUVAC in the sample. ready-to-use reagents make analysis so much simpler. Environmentally friendly In comparison with conventional analysis. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW LANGE Cuvette tests— Insert. and laborious calibrations and time-consuming calculations are no longer necessary. they provide the necessary assurance you need. the multi-purpose cuvette contains considerably reduced amounts of chemicals. For over 50 parameters and more than 90 measuring ranges Cuvette tests cover all water analysis applications. reagents dosed with the required amount and results are calculated automatically. Plus. as they are integrated in the test. The multi-purpose cuvette—ready to use reagents—all you need in one cuvette! www. Light source Reference detector So easy to use Pre-portioned. Solutions do not need to be prepared. finish! Our cuvette tests cover all water analysis applications: a complete solution. From sampling and sample preparation to measurement data processing.44 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. even under the most difficult conditions.hach-lange. Rinsing steps and reagent blank values are eliminated. The cuvette is a closed system. With the help of integrated standard solutions and round robin test solutions. from highly polluted industrial wastewater to the detection of traces of contamination in drinking water.com . Fast results Cuvette tests do not require any tiresome preparations. the measurement result is immediately available. read. Together with photometers and accessories. O2. High levels of reliability The elegant. HACH LANGE also help users to meet their legal obligations by ensuring proper disposal. which guarantees maximum safety for the analyst and the environment. simple handling of the cuvette tests automatically eliminates many sources of error. Cuvette tests come in a fully equipped box and can be used immediately. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. Approved for consent limits Cuvette tests are officially approved for legally required consent limits. anywhere. cuvette tests form a comprehensive and accurate measuring system. 5 mg/l > 2 BU _ 0.5 mg/l 0.02 – 0.069 0. round robin test solutions and spiking.1 – 100 mg/l Ca 0. Surfactants.5 – 7. soil and flaws on the glass of the cuvette are detected and the measurements taken at these points are rejected.0 mmol/l 0.088 0 .05 – 20 mg/l PO4-P 0.23 – 35 mg/l NO3-N 1 – 155 mg/l NO3 0.015 – 6 mg/l NO2-N 0.5 mg/l 0. any scratches.0 71 0.1 – 8 mg/l 2 – 100 g/l Cu 0. cat.6 – 30 mg/l PO4-P 5 – 90 mg/l PO4 0.12 g/l 0.1 – 6 mg/l 5 – 120 g/l 0.000 mg/l 0. or anion.45 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW 10 measurements in one rotation IBR-Laser (Integrated barcode reader) The perfect system: I. User friendly Simple and well-designed to prevent errors from occurring.0 Only with LANGE cuvette tests! As the cuvette rotates. Iron (II + III) Lead Magnesium NUMBER 1 1 1 4 2 1 2 1 1 1 1 1 1 7 1 1 1 2 1 1 2 2 1 1 MEASURING RANGES 0.05 – 200 mg/l 1.02 – 0.05 – 0. Ready to use: carry out the test without having to wade through complicated instructions.2 – 6 mg/l .04 – 2.0 71 0. nonion.3 Alcohol Aluminium Ammonium AOX Bitter units BOD5 Boron Cadmium Carbonate. Fully automatic photometry LANGE cuvette tests are automatically measured correctly the user does not even have to press a button.05 – 2 mg/l Cl2/ O3 0. Officially approved.3 – 20. residual hardness (Ca + Mg) Iron. DW PW 5 Detector 71 0.015– 0. Tin TOC Vicinal dikteones Zinc NUMBER 2 1 1 2 2 3 1 2 1 3 1 2 1 1 2 2 2 1 5 1 1 MEASURING RANGES 3 – 300 mg/l 0.3 mg/l 55 – 550 mg/l CO2 1 – 70 mg/l 0.2 – 2 mg/l 0.000 mg/l TOC 0. finish! The perfect system: II. in mg/l Easy to use: Insert.500 mg/l acetic acid 0. The perfect system: III.0 70 0 .15 – 60 mg/l PO4 8 – 50 mg/l 0.5 mg/l 0.000 mg/l 0.500 mg/l – 2 – 150 mg/l 40 – 900 mg/l 0.03 –1 mg/l 5 – 60. CO2 Chloride Chlorine/Ozone Chromium (III + VI) COD Colour developer CD 2/3/4 Copper Copper baths (acidic) Cyanide Fluoride Formaldehyde Hardness. The variety of measuring ranges PARAMETER Acid capacity KS 4.0 70 0 .01 – 0.15 – 50 mg/l Mg 0. Precision plus safety 100% safe every step of the way: – No contact with reagents. The photometer: – Identifies the cuvette test from its barcode (IBR) – Rotates the cuvette and takes 10 measurements.015 – 130 mg/l NH4-N 0. thanks to DOSICAP ZIP – Automatic measurement with barcode reader – Completely reliable results with ADDISTA standards.5 – 10 mg/l 0.5 mg/kg diacetyl 0. With brief instructions and pictures on the cuvette compartment lid. read.5 – 1.05 – 2.1 – 2 mg/l 3 – 3.01 – 0.5 – 8. LATON Organic acids Phenol Phosphorus (ortho) Phosphorus (ortho + total) Potassium Silver Sludge activity Starch Sulphate Surfactants. e. eliminating outliers – Calculates the result immediately.2 – 6 mg/l 0.05 – 20 mg/l NO2 1 – 100 mg/l TNb 50 – 2.1 – 2 mg/l 0.6 mg/l 0.1 – 1.5 – 50 mg/l PARAMETER Molybdenum Nickel Nickel baths.2 71 0 . acidic Nitrate Nitrite Nitrogen (total).g.650 mg/l 0.069 0 .5 g/l 0.0 70 0 . 0.0. 3.0. 5.2.Total hardness as CaCO3 .5. 10 – 20 steps Variable. 1. 0. 50 50 2757150 4. 10.2 – 8. 0. 4.3. 300.hach-lange. 120. 40. 5.5.2.0. F 2822800 0.46 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. 4. 30. 50. 2.000 2745250 2793844 2793828 0. 8. 180.15. 15. 0.15.25.5. 500 ppb 0. 1. 80.4 50 2755250 COPPER 0 – 3 mg/l HARDNESS (total) as CaCO3 0 – 425 mg/l 0.8. O2. 30.0 mg/l ARSENIC 0 – 500 ppb 0 – 4. 7.5. 5. 250. 3 25 2745125 IRON (total dissolved) 0 . 50.000 mg/l CHLORIDE (free + total) 0 –10 mg/l 0. 25.3. 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Visual tests from HACH LANGE at a glance Test strips MEASURING RANGE SCALING TESTS/ PKG HAZARD CODE* ART. 0. 8. 0. 9 50 2745650 0.000 ppb CHLORIDE 30 – 600 mg/l 300 – 6. 75. 2. 7. 120. F T+. 1. 6 25 2755325 0. 1.5. 175. 0. 1.5 mg/l NITRATE + NITRITE 0 – 50 mg/l NO3 0 – 3 mg/l NO2 pH 4–9 PHOSPHATE (ortho) as PO4 0 – 50 mg/l 0. 3. 120. 0.0. 15. 240 50 2744850 0 –10 mg/l 0 –10 mg/l 0 –25 mg/l 0 –425 mg/l 0 –240 mg/l 6. 6. 80. 0. 10. 425 50 250 1. 425 0.0 50 250 2745050 2793944 Variable.Total chlorine .6. 1. 35. 7. 1.0. 70.Free chlorine .500.4 0.8. 1. 180. 0. 2. 7.0 0. 1.0. 4. 5 25 Xi 2745325 ➔ *Hazard symbol with description see page 60 www. 25 0. 25. 0.5. 3 25 25 2745425 0.5. 10.0 0. 20. 10. 4. 0. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. 10. 1.2. NO. 2. 240 6.000 ppb 100 100 T+.com .Alkalinity as CaCO3 . 100 – 200 steps 40 40 2744940 2751340 0. 40. 2.0.0. 50 0.pH ALKALINITY as CaCO3 0 – 240 mg/l AMMONIUM as NH4-N 0 – 6. 5-in-1-TEST STRIPS 5 parameters per test strip . 250. 6. 120. 1. 50. 7 mg/l 0 – 3. Xn 1252400 2267100 2266900 224100 2428700 Phenolphthalein Phenolphthalein 5 – 100 mg/l CaCO3 20 – 400 mg/l CaCO3 385 – 8.47 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Test strips Colour disk Colour cube Drop count test Digital titrator Colour disks.1 mg/l 0.2 mg/l 0.1 mg/l 0.5 mg/l 0.5 mg/l 0 – 0. 5 ALKALINITY Drop count titration Drop count titration AMMONIUM Colour Colour Colour Colour Colour cube cube cube disk NI-8 disk NI-SA Nessler’s Reagent Salicylate Salicylate Nessler’s Reagent Salicylate 0 – 2.000 mg/l 5 mg/l 20 mg/l 500 mg/l 5.1 mg/l 50 25 100 200 2060300 2502050 223102 1454201 CHLORINE (free + total) Colour disk CN-66 Colour disk CN-70 Colour disk CN-80 DPD DPD DPD 0 – 3.7 mg/l 0 – 3.1 mg/l 0.2 mg/l 0.7 mg/l 0 – 3.02 mg/l 0.5 mg/l 0 – 0.1 mg/l 0.2 – 4 mg/l 1 – 20 mg/l 0.5 mg/l 0 – 3.1 mg/l 25 25 25 100 100 T+.5 mg/l 0.5 mg/l 10 – 200 mg/l 0.5 mg/l 0 – 2.2 mg/l 1.7 mg/l 0 – 3.000 mg/l 5. N 144001 208601 DPD 0 – 3. 0.000 mg/l 100 100 T. phenolphthalein 5 – 100 mg/l CaCO3 20 – 400 mg/l CaCO3 5 mg/l 20 mg/l 100 222301 METHOD MEASURING RANGE DETECTION LIMIT TESTS/ PKG HAZARD CODE* ART.1 mg/l 10 mg/l 0.1 mg/l 0.5 mg/l 0 – 0. C.5 mg/l 0.8 mg/l NH4-N 0 – 3 mg/l NH4-N 0 – 2.5 mg/l NH4-N 0. N C.5 mg/l 0 – 3.1 mg/l 0.5 mg/l NH4-N 0 – 0.0 mg/l 0.5 mg/l 0 – 2.1 mg/l 0.5 mg/l 0 – 0. Xn T+.8 mg/l NH4-N 0 – 0.000 – 100.5 mg/l 0.02 mg/l 0. colour cubes and drop count tests TYPE OF MEASUREMENT ACIDITY Drop count titration Methyl orange. N T.5 mg/l tot.6 mg/l 50 2194000 Drop count titration CD-51 Silver nitrate CHLORINE (free) Colour Colour Colour Colour cube disk disk CN-66F disk CN-70F DPD DPD DPD DPD 0 – 2. 50/50 100/100 100/100 223101 1454200 2129000 CHLORINE (total) Colour Colour Colour Colour cube disk disk CN-66T disk CN-70T DPD DPD DPD DPD Thiosulphate Thiosulphate 0 – 2.02 mg/l 0.0 mg/l 50 25 100 200 100 100 Xi Xi 2060400 2503050 223103 1454202 2444400 225401 Pipette CN-21P Pipette CN-65 ➔ *Hazard symbol with description see page 60 .0 mg/l 0 – 10 mg/l tot. N C.500 mg/l CaCO3 100 100 2444301 2314500 BROMINE Colour cube CHLORIDE Drop count titration 8-P Silver nitrate 5 – 100 mg/l 20 – 400 mg/l 500 – 10.1 mg/l 0. NO.02 mg/l 0. 05% 0. O2. 1.1 mg/l 50/50 T.5 mg/l 0 – 0.5 mg/l 0. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.0 mg/l 0.05 mg/l 25 50 Xn Xn 2182200 2193800 COPPER (free) Colour disk CU-6 CYANIDE (free) Colour cube CYN-3 CYANURIC ACID Turbidity CY-3 DETERGENTS (anionic) Colour disk DE-2 FORMALDEHYDE Colour comparison FM-2 Drop count titration FM-1 MBTH Thymolphthalein 0.0 mg/l 0 – 1. 0.48 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.05 mg/l 32 Xn 143203 Turbidity 20 – 100 mg/l 20 mg/l 50 185102 Pyrdine-pyrazolone 0 – 0.1 mg/l 5 mg/l 50 100 100 Xi Xi Xi 1252700 183400 222702 COLOUR Colour disk CO-1 APHA platinumcobalt standard 0 – 100 units 0 – 500 units 5 units 25 units 223400 COPPER Colour cube Long-path colour cube COPPER (free + total) Colour disk CU-5 Bicinchoninate hydrosulphite reduction 0 – 5 mg/l 0.50% 100 100 Xn. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Visual tests (2) Colour disks. NO.5 mg/l 0.25 mg/l 0.1 mg/l 100 1421300 Bicinchoninate/ hydrosulphite Porphyrine 0 – 2.5.1 mg/l 100 Xn 2194100 GLUTARALDEHYDE Colour disk GLYCOL in oil or water Colouration EG-1 Presence/absence 0 – >150 mg/l 25 T.5 – 10% 0.000 mg/l 0. Xn 2587200 HARDNESS (total + Ca + Mg) as CaCO3 Drop count titration HA-4P EDTA Drop count titration EDTA HA-4P/MG-L 17 – 340 mg/l 20 – 400 mg/l 17 mg/l 20mg/l 100 100 C C 145700 145701 ➔ *Hazard symbol with description see page 60 www. N Xn. CHROMIUM (VI) Colour cube Diphenylcarbazide Colour disk CH-8 Diphenylcarbazide Drop count titration CH-14 Diphenylcarbazide 0 – 1.com .2 mg/l 0.01 mg/l 100 201002 Bicinchoninate 0 – 5 mg/l 0. colour cubes and drop count tests (2) TYPE OF MEASUREMENT CHROMIUM (III.hach-lange.5 – 4. Xi.5 0.5 mg/l 100 C.05 – 1% 0. VI) Colour cube CH-12 Diphenylcarbazide hypobromite oxidation 0 – 1. F 2267200 2183100 Toluidine blue chloroform 0 – 1. C 222800 METHOD MEASURING RANGE DETECTION LIMIT TESTS/ PKG HAZARD CODE* ART.5 0.3 mg/l 0. C 2185600 0.5 mg/l 5 – 100 mg/l 50 – 1.000 mg/l 0. 002 mg/l 0.0 mg/l 0.1 mg/l 0.2 mg/l 100 Xn.10 phenanthroline 0 – 10 mg/l 0.2 mg/l 0 – 0.2 mg/l 1 mg/l 0. NO.10 phenanthroline 1.10 phenanthroline 1. colour cube Colour cube Colour disk NI-11 Colour disk NI-14 Cadmium reduction Cadmium reduction Cadmium reduction Cadmium reduction 0 – 50 mg/l NO3-N 0 – 50 mg/l NO3-N 0 – 50 mg/l NO3-N 0 – 1 mg/l NO3-N 1 – 10 mg/l NO3-N 1 mg/l 10 mg/l 1 mg/l 0.02 mg/l 0. N T.1 mg/l 0.5 mg/l 50 2193900 IRON (II) Colour disk IR-18C MANGANESE Colour disk MN-5 Colour disk MN-PAN MOLYBDENUM Colour disk MO-2 Colour disk MO-LR NITRATE ACCUVAC. N 146700 2350800 1.2 mg/l 0.05% 100 Xi 2687200 IODINE Colour cube IRON ACCUVAC kit Colour cube Colour cube Colour disk IR-18 Colour disk IR-18A Colour disk IR-18B Colour disk IR-21 Colour disk IR-24 1.0 mg/l 0.49 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Test strips Colour disk Colour cube Drop count test Digital titrator TYPE OF MEASUREMENT HARDNESS (total) as CaCO3 Drop count titration 5-EP MG-L Drop count titration 5-B Drop count titration 5-EP Drop count titration HA-71A HYDRAZINE Colour disk HY-2 HYDROGEN PEROXIDE Drop count titration METHOD MEASURING RANGE DETECTION LIMIT TESTS/ PKG HAZARD CODE* ART.10 phenanthroline 1.5 mg/l 0.2 mg/l 0 – 1. colour disk.2 – 2 mg/l 1 – 10 mg/l 0. N 2511050 1403700 146803 1416100 Mercaptoacetic acid Ternary complex 0 – 10 mg/l 0 – 50 mg/l 0 – 3 mg/l 0.0 mg/l 0 – 0.2 mg/l 1 mg/l 2 mg/l 0.01 mg/l 25 50 50 100 100 100 100 50 Xn Xn Xn Xn Xn Xn Xn T 2507050 1400800 2543500 146400 146500 146401 2299300 255600 DPD 0 – 2.7 mg/l 0.2 mg/l 25 50 100 100 Xn T.2 mg/l 1 mg/l 100 Xi 2291700 HYPOCHLORITE Drop count titration CH-HR Thiosulphate 5 – 15% Cl2 50 – 150 g/l Cl2 0. Xn 1419301 2359300 Periodate PAN 0 – 3. EDTA EDTA EDTA EDTA 20 – 400 mg/l 17 – 510 mg/l 17 – 510 mg/l 1 – 20 mg/l 20 mg/l 17 mg/l 17 mg/l 1mg/l 100 100 100 100 Xn Xi Xn Xi 145401 145300 145400 145201 5 P-dimethylamin-benzaldehyde 0 – 1.05 mg/l 0.02 mg/l 0. O T. N T. N 2667200 ➔ *Hazard symbol with description see page 60 .10 phenanthroline 1.10 phenanthroline TPTZ FerroZine 0 – 10 mg/l 0 – 5 mg/l 0 – 10 mg/l 0 – 5 mg/l 0 – 1 mg/l 0 – 10 mg/l 0 – 0.01 mg/l 0.02 mg/l 300 C 184900 Thiosulphate 0.10 phenanthroline 1.1 mg/l 100 100 Xi.05 mg/l 100 50 Xi.1 mg/l 0 – 1. T.01 mg/l 100 T.7 mg/l DEHA 0.065 mg/l DEHA 0 – 0. O2.75 mg/l 0 – 1.2 – 4 mg/l 1 – 20 mg/l 0.8 – 10 9. colour cubes and drop count tests (3) TYPE OF MEASUREMENT NITRATE + NITRITE Colour disk NI-12 Cadmium reduction Diazotization 0 – 50 mg/l NO3-N 0 – 0. Xn.5 3–5 5.2 mg/l 25 25 100 Xi C.25 mg/l 0 – 0.1 0.1 0.5 mg/l NO2-N 1 mg/l 0.2 mg/l 2 mg/l 40 mg/l 0.02 mg/l 0. N 2501050 2515050 146900 Diazotization Diazotization Diazotization 0 – 1.1 mg/l 1 mg/l 0.5 mg/l 0 – 2.05 mg/l 12/24 12/24 12/24 100 Xn Xn Xn 2516050 2517050 2518050 2064400 T T T T T T T PHENOL Colour disk PL-1 Aminoantipyrine 0 – 1 mg/l 0 – 5 mg/l 0.001 mg/l 0.5 0. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.1 0.1 0.2 – 6.5 7.5 6.5 0.1 50 50 200 200 200 200 200 300 200 1251900 2067100 147004 147006 147008 147009 147010 147011 147014 Indigo Indigo Indigo DPD 0 – 0.5 – 8.375 mg/l DEHA 0 – 1.01 mg/l 50 100 100 Xi Xi Xi 2059600 224000 2182000 OZONE ACCUVAC ACCUVAC ACCUVAC Colour disk OZ-2 pH Colour Colour Colour Colour Colour Colour Colour Colour Colour cube cube disk 17D disk 17F disk 17H disk 17J disk 17M disk 17N disk 17S Phenol red Bromothymol blue Dinitrophenol Bromothymol blue Phenol red Thymol blue Alizarin yellow Mixed indicator Bromocresol purple 6.5 – 7.5 – 8.023 mg/l 100 C 2168200 Winkler Winkler Winkler 0 – 1 mg/l 0 – 15 mg/l 0.05 mg/l 0.hach-lange.1 mg/l 1 mg/l 0.5 mg/l PO4 0 – 45 mg/l PO4 0 – 1 mg/l PO4 0 – 5 mg/l PO4 0 – 50 mg/l PO4 0 – 1 mg/l PO4 0 – 5 mg/l PO4 0 – 50 mg/l PO4 0 – 5 mg/l PO4 1 mg/l 0.5 – 8.5 0.2 mg/l 0.0 mg/l NO2-N 0 – 100 mg/l NO2 0 – 2.1 mg/l 100 Xi.005 mg/l 0.3 mg/l 0. NITRITE Colour cube Colour disk NI-6 Colour disk NI-15 OXYGEN Colour disk/ACCUVAC Colour disk/ACCUVAC Drop count titration OX-2P OXYGEN SCAVENGER Colour disk DH-1 Iron reduction 0 – 0.2 mg/l 0.1 0.7 – 11.02 mg/l 0. N 1408100 METHOD MEASURING RANGE DETECTION LIMIT TESTS/ PKG HAZARD CODE* ART. filtration Colour disk/ACCUVAC kit Ascorbic acid 100 Xi 224801 Ascorbic acid 25 Xi 2508050 ➔ *Hazard symbol with description see page 60 www.8 0.com . O 2483600 PHOSPHATE (ortho) Colour cube Colour disk PO-14 Colour disk PO-19 Ascorbic acid Tin method Ascorbic acid 0 – 5 mg/l PO4 0 – 4.1 mg/l 50 100 100 Xi C Xi 1252200 147500 224800 Colour disk PO-19A incl.05 mg/l 0.01 mg/l 0.02 mg/l 0.50 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.1 mg/l 1 mg/l 0. NO.02 mg/l 0.6 4 – 10 5.000 mg/l NO2 0 – 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Visual tests (3) Colour disks.5 mg/l NO2-N 0.5 5. 1 mg/l 1 mg/l 0. F 193701 TRIAZOLES Colour disk TZ-1 WATER in oil Volumetric WO-1 Calcium hydride 0 – 1% 0 – 10% 0.01 mg/l 0.51 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Test strips Colour disk Colour cube Drop count test Digital titrator TYPE OF MEASUREMENT PHOSPHATE (ortho + meta) Colour disk PO-23 Colour disk PO-23A incl.55 mg/l 0 – 2.5 mg/l 50 2167502 ➔ *Hazard symbol with description see page 60 .05 mg/l 0. digestion 0 – 1 mg/l PO4 0 – 5 mg/l PO4 0 – 50 mg/l PO4 0. PhosVer3 PhosVer3 0 – 5 mg/l PO4 0 – 50 mg/l PO4 0 – 5 mg/l PO4 0 – 50 mg/l PO4 0.5 mg/l 5 mg/l 100 T.5 mg/l 60 60 30 T.02 mg/l 100 100 Xi.1 mg/l 1 mg/l 50 C.02 mg/l 0. NO.25 mg/l 0 – 11.1 mg/l 1 mg/l 100 100 C C 224902 224903 5 PhosVer3. filtration PHOSPHATE (total) Colour disk PO-24 METHOD MEASURING RANGE DETECTION LIMIT TESTS/ PKG HAZARD CODE* ART.25 mg/l 0. O 225001 PHOSPHONATE Colour disk PN-10 UV digestion Ascorbic acid 0 – 5 mg/l PO4 0 – 125 mg/l PO4 1 mg/l 100 2113302 SILICA Colour disk SI-5 Colour disk SI-7 SULPHATE Turbidity SF-1 SULPHIDE Colour disk HS-WR Methylene blue 0 – 0.5 mg/l 2.2 mg/l 25 F 2237300 As benzotriazole 0 – 15 mg/l 0. Xi 1455400 2255000 SULPHITE Drop count titration SU-5 Iodometry 1 – 20 mg/l 10 – 200 mg/l 1 mg/l 10 mg/l 100 Xi 148002 TANNIN/LIGNIN Colour disk TA-3 Tyrosine 0 – 15 mg/l 0 – 150 mg/l 0. Xn Xn. C 223801 Turbidity 50 – 200 mg/l 50 mg/l 100 225100 Heteropoly blue Heteropoly blue 0 – 40 mg/l 0 – 800 mg/l 0 – 1 mg/l 1 mg/l 20 mg/l 0. C.400 mg/l ALKALINITY 10 – 4. NO.000 mg/l CHROMATE 20 – 400 mg/l CHROMIUM (VI) 20 – 400 mg/l HARDNESS (Ca) 1 – 16 °dH 10 .05 mg/l 100 2445300 Mercury nitrate Silver nitrate 10 mg/l 10 mg/l 100 50 T+. N T.000 mg/l CaCO3 See manual CALCIUM 10 – 160 mg/l 100 – 4.000 mg/l 10 – 10. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.0 mg/l CHLORINE (total) 20 – 2.000 mg/l CHLORINE (free + total) 0 – 3.000 mg/l CaCO3 ManVer/EDTA ManVer/EDTA ManVer/EDTA ManVer/EDTA 1 °dH 10 °dH 10 mg/l CaCO3 100 mg/l CaCO3 100 100 100 100 Xi Xi Xi Xi 2447800 2447900 2448000 2448100 CalVer/EDTA CalVer/EDTA CalVer/EDTA CalVer/EDTA 1 °dH 10 °dH 10 mg/l CaCO3 100 mg/l CaCO3 100 100 100 100 C C C 2447300 2447400 2447200 2447500 Thiosulphate 20 mg/l 100 2272400 Sodium thiosulphate 20 mg/l 100 2272400 Thiosulphate 20 mg/l 100 2272500 DPD 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Visual tests (4) Tests with cartridges for the digital titrator MEASURING RANGE METHOD DETECTION LIMIT TESTS/ PKG HAZ.000 mg/l CHLORIDE 10 – 8.000 mg/l CaCO3 HARDNESS (total) 1 – 16 °dH 10 . N 2272600 2288000 CalVer/EDTA CalVer/EDTA 10 mg/l 100 mg/l 100 100 C C 2447200 2447500 Phenolphtalein Acid titration 10 mg/l 100 Xi 2271900 Sodium hydroxide 100 100 2460200 Methyl orange/phenolphthalein 10 mg/l 100 C 2272800 Titration with lye HARDNESS (total + Ca + Mg) 10 . CODE* ART.000 mg/l CaCO3 ACIDS (volatile) 100 – 2.52 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. ACID See manual ACIDITY 10 – 4.000 mg/l CaCO3 EDTA EDTA EDTA 10 °dH 10 mg/l CaCO3 100 mg/l CaCO3 100 100 100 C C C 2448500 2448600 2448700 ➔ More information about the digital titrator: see page 77 www.com .>100 °dH 10 – 160 mg/l CaCO3 100 – 4.>100 °dH 10 – 160 mg/l CaCO3 100 – 4.hach-lange.>100 °dH 10 – 160 mg/l CaCO3 100 – 4. O2. 53 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Test strips Colour disk Colour cube Drop count test Digital titrator MEASURING RANGE METHOD DETECTION LIMIT TESTS/ PKG HAZ.co. C.hach-lange.uk www.100 2270701 EDTA EDTA 1 mg/l 20 mg/l 100 100 C C 2447200 2447500 Sulphosalicylic acid/EDTA Sulphosalicylic acid/EDTA 10 mg/l 100 mg/l 100 100 2449200 2449300 Iodometric 50 g/l 100 2687000 5 www. HYPOCHLORITE 50 – 150 g/l Cl2 IRON 10 – 100 mg/l 100 – 1.com Order simply and quickly Request reagent recycling ! Easy login Simple navigation Documents and accessories for each product ➔ More information about the digital titrator: see page 77 ➔ Order simply and quickly Choose your product and request a quotation Contents of your shopping basket ➔ For more information about ordering on the Internet see page 146 .000 mg/l MAGNESIUM 1 – 20 mg/l 20 – 200 mg/l NITRITE 100 – 2. CODE* ART. NO.4 – 4 mg/l 100 Xi 2272300 Winkler 1 mg/l 50 T.hach-lange. N 2272200 Cerimetric C.500 NaNO3 OXYGEN 1 – 10 mg/l SULPHITE 10 – 800 mg/l Iodometric 0. Xn C. O2. N Xn. F LCK391 ATRAZINE IM BARIUM PP AV 1 – 100 mg/l 1 – 100 mg/l Turbidity measurement Turbidity measurement ● ● ● ● ● ● ● ● Lower ppb Immunoassay ● ● ● ● T 2762700 Xi Xi 1206499 2513025 BENZOTRIAZOLE or TOLYTRIAZOLE PP 1 – 16 mg/l 1 – 20 mg/l UV ● ● ● ● ● Xn 2141299 LCK ➔ LANGE cuvette test ➔ TEST’N’TUBE HPT PP AV ➔ HACH pipette test ➔ Powder Pillow test ➔ ACCUVAC RS IM RL ➔ Reagent solution ➔ Immunoassay ➔ Rapid liquid system LCW ➔ LANGE pipette test TNT www.5 mg/l ● ● ● ● ● ● T.02 – 0. N Xn.2 – 5.hach-lange. F LCK390 AOX (fast digestion) LCK ARSENIC RS 0 – 0.3 LCK 0. NO.05 – 3 mg/l ● ● ● ● ● ● ● 0. F Xi LCK301 2603700 2242000 AMMONIUM LCK LCK LCK LCK PP RS TNT TNT 0.005 – 0. N Xn.com .250 mg/l 0.800 mg/l Chromazurol S Eriochrome cyanine R Aluminon ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● T Xn.50 mg/l NH4-N 0.50 mg/l NH4-N 0.50 mg/l NH4-N 0.200 mg/l Silver diethyldithiocarbamate ● ● ● ● 0.54 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.0 mmol/l LANGE method ● ● ● ● ● LCK362 ALACHLOR in water IM ALCOHOL LCK 0.5 mg/l 0.4 – 50.5 – 8.01 – 0.015 – 2 mg/l NH4-N 1 – 12 mg/l NH4-N 2 – 47 mg/l NH4-N 47 – 130 mg/l NH4-N 0. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. N C. C.0 mg/l NH4-N Indophenol blue Indophenol blue Indophenol blue Indophenol blue Salicylate Nessler Salicylate Salicylate ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn.0 mg/l CTAB Direct binary complex ● ● ● ● Xi 2459200 T.02 – 2. C. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Photometric tests from HACH LANGE at a glance XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE MEASURING RANGE METHOD LA SA SA 50 ART.02 – 2.002 – 0. Xn C C. Xn LCK304 LCK305 LCK303 LCK302 2668000 2458200 2604545 2606945 AMMONIUM (quarternary compounds) PP AOX LCK 0.12 g/l Alcohol oxidase ● ● ● ● ● ● ● Threshold value (ppb) Immunoassay ● ● T 2813000 LCK300 ALUMINIUM LCK PP PP 0.01 – 0. ACID CAPACITY KS 4.008 – 0. 50 mg/l 0. Xn C. C T. page 29 ● Lab.0 mg/l Cl2 0. C.000 mg/l 0. Xn.05 – 4.co.0 mg/l Iron III thiocyanat Mercury thiocyanate ● ● ● ● ● ● ● ● ● ● ● T. N LCK241 5 Dilution method Dilution method ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xi C. BITTER UNITS > 2 BU _ LCK BOD5 LCK LCK BORON LCK PP PP BROMINE PP AV 0.02 – 0.5 – 12 mg/l 4 – 1.uk www. analysers see page 83 WW DW PW Cuvette Test (LCK) Powder Pillow (PP) ACCUVAC (AV) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● 00 30 SA LA LA 00 28 50 DR DR TYPE MEASURING RANGE METHOD LA SA SA 50 ART.3 mg/l 0 – 80 µg/l Cadion Dithizone ● ● ● ● ● ● ● ● ● ● T. Xn 2805145 2802246 CHLORIDE LCK RS 1 – 70 mg/l 70 – 1.hach-lange. O LCK554 LCK555 Azomethine H Carmine method Azomethine H ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xi LCK307 1417099 2666900 DPD DPD ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2105669 2503025 CADMIUM LCK RS 0.50 mg/l 0. N T+. N LCK308 224200 CARBONATE/CARBON DIOXIDE LCK 55 – 550 mg/l CO2 pH indicator ● ● ● ● ● ● LCK388 CHLORAMINE (mono) TNT TNT 0.05 – 4.hach-lange.1 – 25. F LCK311 2319800 www.02 – 1.0 mg/l 0.5 mg/l 0.1 – 10.2 – 14.650 mg/l MEBAK ● F.55 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 ● Photometers and spectrophotometers see.com Order simply and quickly ! 1) Not measurable on DR 2400 Please note: the measuring ranges can vary from instrument to instrument! ➔ *Hazard symbol with description see page 60 ➔ For more information about ordering on the Internet see page 146 ➔ Order simply and quickly .05 – 2. NO. C.50 mg/l Cl2 Indophenol Indophenol ● ● ● ● ● ● ● ● ● C.50 mg/l 0.04 – 4. Xi LCK313 CHROMIUM (VI) PP AV COBALT PP 0.02 – 2.01 – 0.05 – 1.500 mg/l ClO2 0. Xn 2105569 2502025 1407099 1407099 2556900 2105545 CHLORINE (total) AV PP PP PP RL RL TNT 0.00 mg/l 0.00 mg/l ClO2 Chlorophenol red DPD/glycine Amaranth DPD/glycine ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xi 2242300 2771000 HPT240 2770900 CHLORINE/OZONE LCW 0.00 mg/l 0.1 – 5.02 – 2.0 mg/l 0. CHLORINE (free) PP AV PP PP RL TNT 0.1 – 10 mg/l 0.70 mg/l Diphenylcarbazide Hypobromite oxidation ● ● ● ● ● ● ● ● ● ● ● ● ● Xn.25 mg/l 0.02 – 2.com .01 – 0.1 – 5 mg/l 0.00 mg/l 0.8 mg/l Cl2O DPD ● ● ● ● ● ● ● LCK310 CHROMIC ACID BATHS LCK 50 – 450 g/l CrO3 Intrinsic bath colour ● ● ● ● ● ● ● Xi LCK213 CHROMIUM LCK PP 0.5-diphenylcarbohydrazide ● ● ● ● ● ● ● ● ● ● ● ● Xi Xi 1271099 2505025 T 2651600 LCK ➔ LANGE cuvette test ➔ TEST’N’TUBE HPT PP AV ➔ HACH pipette test ➔ Powder Pillow test ➔ ACCUVAC RS IM RL ➔ Reagent solution ➔ Immunoassay ➔ Rapid liquid system LCW ➔ LANGE pipette test TNT www.02 – 2. NO.01 – 0.01 – 2.003 – 0.04 – 5.04 – 5.00 mg/l DPD DPD DPD DPD DPD DPD DPD ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● C.00 mg/l 2 – 500 µg/l 0.02 – 2. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.005 – 0. C LCS313 2242500 CHROMIUM (III + VI) LCK 0.00 mg/l PAN ● ● ● ● 0.09 – 3.00 mg/l 0.00 mg/l ClO2 0.5 mg/l Cl2/O3 0.00 mg/l ClO2 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Photometric tests (2) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE MEASURING RANGE METHOD LA SA SA 50 ART.1 – 10 mg/l 0.09 – 5.03 – 1 mg/l Diphenylcarbazide ● ● ● ● ● ● ● Xn.01 – 1.4 mg/l Cl2/O3 DPD ● ● ● ● ● ● LCW510 CHLORINE/OZONE/CHLORINE DIOXIDE LCK 0.02 – 2.hach-lange.56 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.70 mg/l 1.03 – 0.5-diphenylcarbohydrazide 1.00 mg/l 0.09 – 5.00 mg/l DPD DPD DPD DPD DPD DPD ● ● ● ● Xi. Xn Xi 2503025 2105669 1406499 1406499 2557000 2563000 2105645 CHLORINE DIOXIDE AV AV HPT PP 0.05-2 mg/l Cl2/O3 0. Xi T. O2.70 mg/l 0. C T. analysers see page 83 WW DW PW Cuvette Test (LCK) Powder Pillow (PP) ACCUVAC (AV) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● ● ● ● 1) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE COD LCK TNT LCK LCK LCK LCK LCK LCK TNT TNT TNT TNT COD ISO LCK LCK COLOUR RS MEASURING RANGE METHOD LA SA SA 50 ART.57 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 ● Photometers and spectrophotometers see. page 29 ● Lab.000 mg/l 15 – 150 mg/l 50 – 300 mg/l 100 – 2.04 – 5. C T.hach-lange.00 mg/l 2 – 210 µg/l Bicinchoninat Bathocuproine disulphonic acid Bathocuproine disulphonic acid Bicinchoninat Porphyrine ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 0.com Order simply and quickly 1) Not measurable on DR 2400 Please note: the measuring ranges can vary from instrument to instrument! ➔ *Hazard symbol with description see page 60 ➔ For more information about ordering on the Internet see page 146 ➔ Order simply and quickly ! .000 mg/l 5. C C T. C T. C T.04 – 5. C T. NO. C C T.hach-lange.000 mg/l Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Chromosulphuric acid Manganese (III) Reactor digestion Chromosulphuric acid ● ● ● ● ● T.500 mg/l 30 – 1. C LCI400 LCI500 5 – 500 units Platinum-cobalt standard ● ● ● ● ● COLOUR DEVELOPER CD 2/3/4 LCK COPPER AV LCK LCK PP PP 0.000 mg/l 200 – 15. 5 – 60 mg/l 0 – 40 mg/l 1.5 g/l LANGE method ● ● ● ● ● ● Xn LCK395 Xn 2504025 LCK529 LCK329 2105869 2603300 Xn www. C C T.co. C LCK414 2415851 LCK014 LCK914 LCK314 LCK614 LCK514 LCK114 2125851 2125951 2623451 2415951 5 0 – 1.000 – 60.01 – 1 mg/l 0.000 mg/l 0 – 150 mg/l Chromosulphuric acid Chromosulphuric acid ● ● ● ● ● ● ● ● ● ● ● ● ● ● T.uk www.5 – 7.000 mg/l 3 – 150 mg/l 20 – 1.000 – 10.000 mg/l 150 – 1. C T.00 mg/l 0.1 – 8 mg/l 0. 6 mg/l Barbituric acid-pyridine ● ● ● ● ● ● ● LCK315 CYANURIC ACID PP 5 – 50 mg/l Turbidity measurement ● ● ● ● ● ● 246066 FLUORIDE AV LCK RS 0.01 – 0.5 – 10 mg/l 0.02 – 2. N LCK319 CYANIDE (free) LCK 0. NO.07– 4. O2.hach-lange.1 – 2 mg/l Ca 0.240 mg/l Pyridine-pyrazalone ● ● ● ● ● ● 2 – 100 g/l Cu Intrinsic bath colour ● ● ● ● ● Xi LCK229 2430200 CYANIDE (easily liberatable) LCK 0.58 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.00 mg/l SPADNS SPADNS SPADNS ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● C C 2506025 LCK323 44449 FORMALDEHYDE LCK LCK PP 0.001 – 0.5 mg/l 0. COPPER BATHS (acidic) LCK CYANIDE PP 0. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.02 – 0.000 µg/l CaCO3 Metal phthalein ● ● ● ● ● ● ● LCK327 RL RL Calmagite Chlorophosphonazo ● ● ● ● ● ● ● ● ● ● ● C 2319900 2603100 HARDNESS (residual) (Ca + Mg) LCK 0.35 mg/l LANGE method ● ● ● ● ● ● ● Xi.6 °dH 0.02 – 2.1 – 1. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Photometric tests (3) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE MEASURING RANGE METHOD LA SA SA 50 ART.03 – 0.com .00 mg/l CaCO3 1 – 1.01 – 1 mg/l 3 – 500 µg/l Acetylacetone Acetylacetone MBTH ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn LCK325 LCS325 2257700 HARDNESS (Ca + Mg) LCK 1 – 20 °dH 5 – 100 mg/l Ca 3 – 50 mg/l Mg 0.00 mg/l 0.15 – 2 mg/l Mg ● ● ● ● ● ● ● Xi LCK427 HYDRAZINE AV LCW RS 4 – 600 µg/l 0.01 – 2 mg/l 4 – 600 µg/l P-dimethylaminobenzaldehyd 4-dimethylaminobenzaldehyd P-dimethylaminobenzaldehyd ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● C 2524025 LCW025 179032 HYDROGEN PEROXIDE LCW 1 – 10 g/l ● ● ● ● ● ● LCW058 LCK ➔ LANGE cuvette test ➔ TEST’N’TUBE HPT PP AV ➔ HACH pipette test ➔ Powder Pillow test ➔ ACCUVAC RS IM RL ➔ Reagent solution ➔ Immunoassay ➔ Rapid liquid system LCW ➔ LANGE pipette test TNT www. O T.800 mg/l 0.1 – 2.05 – 2.07 – 7.N Xn.10 Phenanthroline ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn.02 – 3.07 – 7.02 – 3.02 – 3.10 Phenanthroline 1.400 mg/l 0.00 mg/l 0. N T.2 – 20. C Xi.2 – 6 mg/l 1. N Xn T.00 mg/l 1. 0.3 – 40.00 mg/l 0.5 µg/l Cold vapour concentration ● ● ● ● T.2 – 6 mg/l 0.10 Phenanthroline 1.N 2514025 103769 IRON (II.3 – 40.00 mg/l 0.012 – 1.02 – 1 mg/l 0.009 – 1. N T+. III) LCK LEAD LCK RS RS 0.250 mg/l 0. O 2658300 MOLYBDATE/MOLYBDENUM AV PP PP LCK 0.01 – 1 mg/l 0. N LCW032 2430000 2651700 MENTHOL (in distillate) LCK 0.80 mg/l 0.0 mg/l 0.0 mg/l 0. analysers see page 83 WW DW PW Cuvette Test (LCK) Powder Pillow (PP) ACCUVAC (AV) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE IODINE PP AV IRON AV AV LCK LCW LCW PP PP PP PP RL RS IRON (II) AV PP MEASURING RANGE METHOD LA SA SA 50 ART.01 – 1. Xn T 2522025 2604100 2449400 LCK330 1) Not measurable on DR 2400 Please note: the measuring ranges can vary from instrument to instrument! ➔ *Hazard symbol with description see page 60 .800 mg/l 0. N C LCK306 2243100 2375000 MAGNESIUM LCK 0.009 – 1.700 mg/l Formaldoxime Periodate oxidation PAN ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● T.02 – 3. N 0.00 mg/l 3 – 300 mg/l Mercaptoacetic acid Mercaptoacetic acid Ternary complex Thioglycolic acid ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn Xi. NO.00 mg/l 0.10 Phenanthroline ● ● ● ● ● ● ● Xi LCK320 T+.005 – 0.00 mg/l DPD DPD ● ● ● ● 2105669 2503025 5 0.02 – 3.2 – 5 mg/l 0.400 mg/l 0. page 29 ● Lab. C.009 – 1.10 Phenanthroline FerroZine FerroMo FerroVer FerroZine TPTZ FerroZine FerroZine ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn Xi C ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2507025 2510025 LCK321 LCK521 LCW021 2544800 2105769 230166 2608799 230149 230153 Xn T.5 – 50 mg/l Metal phthalein ● ● ● ● ● ● ● LCK326 MANGAN ESE LCW PP PP 0.59 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 ● Photometers and spectrophotometers see.00 mg/l 0. C.012 – 1.5 – 15 mg/100 ml LANGE method ● ● ● ● C LCW185 MERCURY RS 0.1 – 2 mg/l 0 – 300 µg/l 5 – 150 µg/l PAR Dithizone Column extraction ● ● ● ● ● ● ● ● ● ● ● ● ● 0.007 – 0.400 mg/l FerroVer TPTZ 1.0 mg/l 0. N T.60 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. N T.3 – 30.000 mg/l Dimethylglyoxime Dimethylglyoxime Heptoxime PAN PAN ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● C C Xn T T LCK537 LCK337 2243500 2242600 2651600 NICKEL BATHS (acidic) LCK NITRATE LCK AV AV LCK PP PP PP TNT 0.hach-lange.1 – 10.uk www. NO.hach-lange.3 – 30.5 mg/l NO3-N 1 – 60 mg/l NO3 0.50 mg/l NO3-N 0.0 mg/l NO3-N 0. 0.0 mg/l NO3-N 5 – 35 mg/l NO3-N 22 – 155 mg/l NO3 0. N C LCK339 2511025 2511025 LCK340 2429800 2106169 2106169 2605345 www.007 – 1.05 – 1 mg/l 0. N C T. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Photometric tests (4) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE NICKEL LCK LCK PP PP PP MEASURING RANGE METHOD LA SA SA 50 ART.007 – 1.000 mg/l 0.2 – 30. O2.1 – 10.0 mg/l NO3-N 0.02 – 1. N T.com .80 mg/l 0.23 – 13.co.1 – 6 mg/l 0.hach-lange.6 dimethylphenol Cadmium reduction Cadmium reduction Cadmium reduction Chromotropic acid ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 5 – 120 g/l Intrinsic bath colour ● ● ● ● ● ● ● Xi LCK237 C T.com Order simply and quickly ! C ➔ For more information about ordering on the Internet see page 146 LCK ➔ LANGE cuvette test ➔ TEST’N’TUBE Hazard Code E: Explosive E O F ➔ Order simply and quickly RS IM RL ➔ Reagent solution ➔ Immunoassay ➔ Rapid liquid system Hazard Code C: Corrosive Hazard Code N: Dangerous for the environment HPT PP AV Hazard Code F: Highly flammable ➔ HACH pipette test ➔ Powder Pillow test ➔ ACCUVAC T LCW ➔ LANGE pipette test TNT Hazard Code T: Toxic Hazard Code T+: Very toxic Xn Hazard Code Xi: Irritant Hazard Code Xn: Harmful Hazard Code O: Oxidizing F+ Hazard Code F+: Extremely flammable T+ www.0 mg/l NO3-N 2.0 mg/l NO3-N 0. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.01 – 0.6-dimethylphenol Cadmium reduction Cadmium reduction 2. 6 – 6 mg/l NO2-N 2 – 20 mg/l NO2 0.0 mg/l 1.6 mg/l NO2-N 0.300 mg/l NO2-N 0.5 – 25. Xn 2604545 ORGANIC ACIDS RS 27 – 2. Xi LCK365 OXYGEN BINDER PP 5 – 600 µg/l DEHA Iron reduction ● ● ● ● ● C 2446600 OXYGEN (dissolved) AV AV AV 0.6 dimethylphenol Koroleff digestion + 2.003 – 0.0 mg/l N Titanium trichloride reduction ● ● ● ● C.6 dimethylphenol ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● C C C LCK138 LCK238 LCK338 NITROGEN (total) TNT TNT 0. analysers see page 83 WW DW PW Cuvette Test (LCK) Powder Pillow (PP) ACCUVAC (AV) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE NITRITE LCK AV LCK LCK PP PP TNT MEASURING RANGE METHOD LA SA SA 50 ART.002 – 0. O C. page 29 ● Lab. Kjeldahl PP 1 – 150 mg/l Nessler ● ● ● ● ● T+.005 – 0.015 – 0. N.2 – 25.6 dimethylphenol Koroleff digestion + 2.300 mg/l NO2-N 2 – 250 mg/l NO2-N 0.61 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 ● Photometers and spectrophotometers see.03 mg/l NO2-N 0. LATON LCK LCK LCK 1 – 16 mg/l TNb 5 – 40 mg/l TNb 20 – 100 mg/l TNb Koroleff digestion + 2. NO.002 – 0.1 mg/l NO2 0. 0. C 2495300 NITROGEN (total). inorganic TNT 0.05 – 2 mg/l NO2 0.0 – 40. O 2672245 2714100 NITROGEN (total).500 mg/l NO2-N Diazotization Diazotization Diazotization Diazotization Diazotization Iron (II) sulphate Diazotization ● ● ● ● ● ● ● ● ● ● ● ● ● ● LCK541 Xi Xi Xi Xi Xi Xi 2512025 LCK342 LCK341 2107169 2107569 2608345 5 NITROGEN (total).800 mg/l Esterification ● ● ● ● ● ● ● 2244700 ORGANIC ACIDS (fatty acids) LCK 50 – 2.0 mg/l 6 – 800 µg/l HRDO SHRDO (UHR) Indigo carmine ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xi Xi 2515025 2515025 2501025 1) Not measurable on DR 2400 Please note: the measuring ranges can vary from instrument to instrument! ➔ *Hazard symbol with description see page 60 .0015 – 0.0 mg/l N 10 – 150 mg/l N Persulphate digestion + chromotropic acid Persulphate digestion + chromotropic acid ● ● ● ● ● ● C.500 mg/l acetic acid Esterification ● ● ● ● ● ● ● Xn.3 – 15. 0 mg/l PO4 19 – 3.5 mg/l PO4-P 0.5 – 5 mg/l PO4-P 5 – 15 mg/l PO4 2 – 20 mg/l PO4-P 6 – 60 mg/l PO4 0.62 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.05 – 1. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Photometric tests (5) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● ● ● ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE OZONE AV AV AV PCB IM MEASURING RANGE METHOD LA SA SA 50 ART.02 – 2. Xn LCS349 LCK348 LCK350 2742745 LCK349 LCK ➔ LANGE cuvette test ➔ TEST’N’TUBE HPT PP AV ➔ HACH pipette test ➔ Powder Pillow test ➔ ACCUVAC RS IM RL ➔ Reagent solution ➔ Immunoassay ➔ Rapid liquid system LCW ➔ LANGE pipette test TNT www.50 mg/l PO4 0.5 mg/l PO4-P 0. Xn C.03 – 1.05 – 5 mg/l 5 – 200 mg/l 0. O 2429700 PHOSPHORUS (ortho) AV AV PP RL RL RS TNT TNT LCK 0.04 – 30.06 – 5.5 mg/l PO4 Phosphormolybdenum blue Phosphormolybdenum blue Phosphormolybdenum blue PhosVer 3 with acid hydrolysis Phosphormolybdenum blue ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● C.75 mg/l 0.00 mg/l PO4 0. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.3 – 45. NO.06 – 5.01 – 1.15 – 4.0 – 125.00 mg/l PO4 1.5 – 8.5 units Phenol red ● ● ● ● 2657512 Xn Xn.000 µg/l PO4 0. Xn.01 – 0.com .0 mg/l PO4 0.50 mg/l 1.3 – 45.200 mg/l 4-aminoantipyrine 4-aminoantipyrine 4-aminoantipyrine ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 6.50 mg/l Indigo Indigo Indigo ● ● ● ● ● ● Xn Xn Xn 2516025 2517025 2518025 Threshold values (ppm) Immunoassay for soil and water ● ● ● ● ● ● T. O.0 mg/l PO4 0.0 – 100. Xn C.6 – 30 mg/l PO4-P 5 – 90 mg/l PO4 PhosVer 3 Molybdovanadate PhosVer 3 Molybdovanadate Ascorbic acid Amino acid Molybdovanadate PhosVer 3 Molybdovanadate Vanadate-molybdate ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xi C Xi C C T. O Xi. Xn C.00 mg/l PO4 0. Xn LCK345 LCK346 2243900 PHOSPHONATE PP 0.0 mg/l PO4 1.5 mg/l PO4 0.01 – 0. C C C Xi C 2508025 2525025 2106069 2076049 2678600 2244100 2076032 2742545 2767345 LCK049 PHOSPHORUS (ortho + total) LCK LCK LCK TNT LCK 0.002 – 0. 0.50 mg/l PO4 0. Xn C. F 2773500 pH RS PHENOL LCK LCK PP 0. O2.0 mg/l Persulphate/UV oxidation ● ● ● ● ● ● Xi.3 – 45.01 – 0.02 – 2.hach-lange.02 – 2.25 mg/l 0. F LCK328 2459100 REDUCING AGENT for boiler water LCW 0.1 –7.63 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 ● Photometers and spectrophotometers see.4 mg/l Si 0.700 mg/l LANGE method LANGE method Colorimetric ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 0.2 MEBAK ● ● ● F LCK240 POTASSIUM LCK PP 8 – 50 mg/l 0. F.01 – 1. Xn LCW028 LCS028 2459300 2429600 2553500 2678500 F C Xi LCK354 LCK355 2296600 SLUDGE ACTIVITY LCK STARCH LCK 2 – 150 mg/l Iodine ● ● ● ● ● ● TTC test ● ● ● ● ● ● F LCK318 LCK357 SULPHATE LCK AV LCK PP PP 40 – 150 mg/l 2 – 70 mg/l 150 – 900 mg/l 2 – 70 mg/l 2 – 70 mg/l Barium sulphate Turbidity measurement Barium sulphate Barium sulphate Turbidity measurement ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● T Xn T Xn Xn LCK153 2509025 LCK353 1206599 2106769 1) Not measurable on DR 2400 Please note: the measuring ranges can vary from instrument to instrument! ➔ *Hazard symbol with description see page 60 .8 mg/l 5 – 2.02 – 1 mg/l DEHA LANGE method ● ● ● ● ● ● C LCW250 SELENIUM RS SILICIA LCW LCW PP PP PP PP SILVER LCK LCK PP 0.000 µg/l SiO2 Molybdenum blue Molybdenum blue Heteropoly blue Silicomolybdate Heteropoly blue Heteropoly blue ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn. PHOSPHORUS (total) TNT TNT 0.0 – 100.0 mg/l Kalignost Tetraphenylborate ● ● ● ● ● ● ● ● ● ● ● T. Xi Xn.01 – 1.000 µg/l SiO2 3 – 1. NO. analysers see page 83 WW DW PW Cuvette Test (LCK) Powder Pillow (PP) ACCUVAC (AV) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE MEASURING RANGE METHOD LA SA SA 50 ART.0 mg/l 3 – 1. Xi Xi.0 – 100. Xn.005 – 0. O 2742645 2767245 5 PHOTOMETRIC IODINE SAMPLE LCK Iodine value > 0.8 mg/l SiO2 0.60 mg/l SiO2 1.06 – 3.01 – 0.50 mg/l PO4 1.500 mg/l 0. page 29 ● Lab.04 – 0.0 mg/l PO4 PhosVer 3 with acid-persulphate digestion Molybdovanadate with acid-persulphate digestion C. Xn 2244200 0. Xn.8 – 100 mg/l SiO2 0.00 mg/l Diaminobenzidine ● ● ● ● C. O C.4 – 50 mg/l Si 0.005 – 0. Xn Xi Xi Xi. 64 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.000 mg/l TOC 0. O LCK385 LCK386 LCK387 2760345 2815945 2760445 TOLYLTRIAZOLE PP TOXICITY PP 0 – 100 % inhibition ToxTrak ● ● ● ● ● ● 1 – 20 mg/l UV photolysis ● ● ● ● ● Xn 2141299 C 2597200 LCK ➔ LANGE cuvette test ➔ TEST’N’TUBE HPT PP AV ➔ HACH pipette test ➔ Powder Pillow test ➔ ACCUVAC RS IM RL ➔ Reagent solution ➔ Immunoassay ➔ Rapid liquid system LCW ➔ LANGE pipette test TNT www.275 mg/l LAS MBA Crystal violet ● ● ● ● ● ● ● ● ● ● ● ● ● Xn F. O2. NO. CTAS TBPK.1 – 2 mg/l Dimethylphenylendiamine Methylene blue Dimethylphenylendiamine ● ● ● ● ● ● ● ● ● C T.1 – 5.1 – 20 g/l 6 – 200 mg/l TBPK.0 mg/l C 15 – 150 mg/l C 100 – 700 mg/l C Persulphate (photometric) Persulphate (photometric) Persulphate (photometric) Persulphate (photometric) Persulphate (photometric) Persulphate (photometric) ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn Xn Xn. O LCK380 LCK381 TOC (expulsion method) LCK LCK LCK TNT TNT TNT 3 – 30 mg/l TOC 30 – 300 mg/l TOC 300 – 3. 0.2 – 6. N Xn. CTAS ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn Xn Xn LCK333 LCK334 LCK433 SUSPENDED SOLIDS 0 – 750 mg/l TANNIN + LIGNIN RS TIN LCK 0. O Xn.hach-lange. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Photometric tests (6) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE SULPHIDE LCK RS LCW SULPHITE LCW HPT MEASURING RANGE METHOD LA SA SA 50 ART.0 mg/l 0. O Xn.0 mg/l LANGE method HACH method ● ● ● ● ● ● ● ● ● C LCW054 HPT430 SURFACTANTS (anionic) LCK RS 0.1 – 5 mg/l 0. T LCK332 2446800 SURFACTANTS (cationic) LCK 0. O Xn.2 – 2 mg/l CTAB ● ● ● ● ● ● ● F. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.3 – 20.com . O LCK359 TOC (difference method) LCK LCK 2 – 65 mg/l TOC 60 – 735 mg/l TOC Persulphate (photometric) Persulphate (photometric) ● ● ● ● ● ● ● ● ● ● ● ● ● ● Xn. C C LCK653 2244500 LCW053 0.1 – 2 mg/l 5 – 800 µg/l 0.2 – 2 mg/l 0.0 mg/l Tyrosine ● ● ● ● ● ● 2244600 T.1 – 2 mg/l Pyridinfluoron (PYF) ● ● ● ● ● ● ● Photometric ● ● ● ● ● 0. Xn LCK331 SURFACTANTS (nonionic) LCK LCK LCK 0. CTAS TBPK.1 – 9.002 – 0. co. N LCK242 Xn Xn.hach-lange.00 mg/l PAR Zincon ● ● ● ● ● ● ● ● ● ● ● ● ● 0.8 mg/l PAR ● ● ● ● ● ● Xn LCS360 www.2 – 6 mg/l 0. analysers see page 83 WW DW PW Cuvette Test (LCK) Powder Pillow (PP) ACCUVAC (AV) XIO 100 N CA DA S2 PO CK 00 E DR T 82 DR 0 85 DR 0 89 DR 0 24 DR 00/2 50 40 0 HA 00 ZA RD CO DE * ● ● ● ● ● ● 00 30 SA LA LA 00 28 50 DR DR TYPE MEASURING RANGE METHOD LA SA SA 50 ART.com Order simply and quickly Request reagent recycling ! Easy login Simple navigation Documents and accessories for each product Choose your product and request a quotation Contents of your shopping basket 1) Not measurable on DR 2400 Please note: the measuring ranges can vary from instrument to instrument! ➔ *Hazard symbol with description see page 60 ➔ For more information about ordering on the Internet see page 146 ➔ Order simply and quickly . N LCK360 2429300 ZINC (trace) LCK 0.5 mg/kg diacetyl MEBAK ● ● ● T. TPH in water IM Limiting value 2 – 200 mg/l Immunoassay for soil and water ● ● ● ● ● 2774300 5 TRIHALOMETHANE RS 0 – 200 ppb THM Plus ● ● ● 2790800 VICINAL DIKETONES LCK ZINC LCK PP 0. page 29 ● Lab.015 – 0.02 – 0.uk www.hach-lange.01 – 2.65 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 ● Photometers and spectrophotometers see. NO. 5 – 5 mg/l PO4-P 100 – 2.5 mg/l 02 – 03 mg/l 0. E.6 mg/l NO2-N 0.000 mg/l 0.000 mg/l 0.g.5 mg/l PO4-P ART.05 – 1.6 – 6 mg/l NO2-N 0. LCA704 LCA701 LCA705 LCA702 LCA706 LCA707 LCA703 LCA708 LCA709 All ADDISTAs contain 85 ml standard and spiking solution as well as two round robin test solutions.5 mg/l NO3-N 1. This will be checked against HACH LANGE standards and if successful you will be presented with a certificate. NO. For several parameters simultaneously. Free of charge! ADDISTA multistandard solutions for analytical quality assurance of LANGE cuvette tests FOR CUVETTE TEST Ammonium Chloride COD Nitrogen (total) Phosphorus (ortho) Potassium Copper Iron Lead Nickel Sulphate Zinc Aluminium Cadmium Chromium (VI) Chromium (total) Sulphate Ammonium Chloride COD COD ISO Nitrate Phosphorus (ortho) Phosphorus (ortho) Sulphate TOC LCK304 LCK311 LCK414 LCK238 LCK348 LCK328 LCK329 LCK321 LCK306 LCK337 LCK353 LCK360 LCK301 LCK308 LCK313 LCK313 LCK353 LCK303 LCK311 LCK114 LCI400 LCK339 LCK049 LCK350 LCK353 LCK386 CONCENTRATION 0.66 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.02 – 5 mg/l 0.2 – 6 mg/l 0. The comprehensive ADDISTA AQA system for LANGE cuvette tests contains two round robin solutions. NO.5 mg/l PO4-P 40 – 150 mg/l 3 – 30 mg/l 47 – 130 mg/l NH4-N 1 – 70 mg/l 1.015 – 2 mg/l NH4-N 1 – 70 mg/l 5 – 60 mg/l 5 – 40 mg/l TNb 0.02 – 0.015 – 0. O2. results are only dependable in conjunction with analytical quality assurance (AQA). HACH LANGE offers classic single standard solutions as well as practical multistandard solutions.hach-lange.23 – 13. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.5 – 5 mg/l PO4-P 8 – 50 mg/l 0.6 – 30 mg/l PO4-P 2 – 20 mg/l PO4-P 150 – 900 mg/l 30 – 300 mg/l ART. 25 ml each ➔ More information on LANGE cuvette tests and ADDISTA: see page 44 ➔ All LANGE cuvette tests: see page 54 ➔ For more information about ordering on the Internet see page 146 www.01 – 1 mg/l 0.03 – 1 mg/l 0.com .05 – 1.000 mg/l 0 – 1.03 – 1 mg/l 150 – 900 mg/l 2 – 47 mg/l NH4-N 1 – 70 mg/l 150 – 1. which allow the user to participate in analysis checking free of charge.1 – 2 mg/l 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Standard solutions— Analytical Quality Assurance Analysis is not just about measured values.000 mg/l 20 – 100 mg/l TNb 2 – 20 mg/l PO4-P 50 – 300 mg/l 1 – 16 mg/l TNb 0.2 – 6 mg/l 0.000 – 10.01 – 1 mg/l 0. ADDISTA contains a combined standard and spiking solution as well as two round robin solutions. LCA700 FOR CUVETTE TEST Ammonium Chloride COD COD ISO Nitrate Phosphorus (ortho) Sulphate TOC Ammonium Chloride COD TOC Copper Iron Manganese Nickel COD Nitrite Phosphorus (total) COD Nitrogen (total) Phosphorus (total) COD Nitrogen (total) Nitrite Phosphorus (total) LCK305 LCK311 LCK314 LCI500 LCK340 LCK349 LCK153 LCK385 LCK302 LCK311 LCK014 LCK387 LCK529 LCK521 LCW032 LCK537 LCK614 LCK341 LCK348 LCK514 LCK338 LCK350 LCK614 LCK138 LCK342 LCK349 CONCENTRATION 1 – 12 mg/l NH4-N 1 – 70 mg/l 15 – 150 mg/l 0 – 150 mg/l 5 – 35 mg/l NO3-N 0.1 – 8 mg/l 0.05 – 1 mg/l 50 – 300 mg/l 0.1 – 6 mg/l 150 – 900 mg/l 0. Other benefits include: – Internal checking of method and equipment – Detection of sample related interferences – External confirmation through a round robin test. each ADDISTA provides seamless quality assurance for the LANGE cuvette analysis system.000 mg/l 300 – 3. 000 mg/l 1.000 ml 500 ml 100 ml 500 ml 500 ml 10 ml/16 a* 100 ml ART. APHA Phosphate as PO43-* Phosphorus as P* Potassium as K* Silica as SIO2* Silver as Ag* Sulphate as SO42-* Sulphite as SO32Zinc as Zn* CONC.67 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 LANGE single standard solutions FOR CUVETTE TEST AOX BOD5 Chlorine LCK390 LCK555 LCK310 DETERMINATION 6 10 20 ART.65 mg/l PO4-P 50 mg/l SO4 8 mg/l TOC 2833649 5 2833049 Wastewater.000 mg/l 100 mg/l VOLUME 100 ml 1l 10 ml/16 a* 100 ml 10 ml/16 A* 100 ml 100 ml 10 ml/16 a* 100 ml 500 ml 500 ml 500 ml 10 ml/16 a* 1. 15 mg/l NH4-N 2833149 500 mg/l COD 10 mg/l NO3-N 10 mg/l PO4 3. 100 mg/l 1 mg/l 10 mg/l 1.000 mg/l 100 mg/l 50 mg/l 1.0 mg/l 10. 100 mg/l 1. NO. NO. inflow PARAMETER Ammonium COD Nitrate Phosphate Sulphate TOC Ammonium COD Nitrate Phosphate Sulphate TOC 2833349 CONCENTRATION ART.3 mg/l Fe 0. NO.8 °dH Total hardness 100 mg/l CaCO3 5.5 mg/l Fe 5 mg/l Mn 1 mg/l F 2 mg/l NO3-N 8.9 mg/l NO3 Phosphate 2 mg/l PO4 Sulphate 50 mg/l SO4 Calcium 50 mg/l CaCO3 hardness 2. 12842 29153 218710 1417542 1426210 1279142 1419542 1426510 1417642 30749 2340249 256949 2109210 2240442 110649 1461342 257849 2175749 2267410 237842 10 ml/16 A* 1486610 Cadmium as Cd* Calcium as Ca* for hardness Calcium* as CaCO3 (CaCl2) for hardness Chloride as Cl Chlorine as Cl2* 100 ml 100 ml 1l 1402442 2305442 12153 1.000 mg/l 25-30 mg/l 50-75 mg/l Chromium (III) as Cr3+* 50 mg/l Chromium (VI) as Cr6+* 12.1 mg/l Mn 2.000 mg/l 50 mg/l 1. stock as N. NO. 54 ➔ For more information about ordering on the Internet see page 146 .000 mg/l 1. low measuring range 2833449 Water hardness.5 mg/l Cobalt as Co* 1. 2833749 APPLICATION Wastewater. high measuring range Inorganic substances in drinking water PARAMETER Copper Iron Manganese Copper Iron Manganese Fluoride Nitrate CONCENTRATION 1 mg/l Cu 0.000 mg/l glucose/ glutamic acid 100 mg/l 10 mg/l 1.000 mg/l COD* 300 mg/l 300 mg/l 1.000 mg/l 10 mg/l 250 µgl 1 mg/l 25 mg/l 100 mg/l 1 mg/l 1. 3 Other concentrations of HACH single standard solutions available on request ➔ More information on the HACH tests: see page 41 ➔ All HACH tests: see pages 46. NO.000 mg/l 500 mg/l 1. 2 ***) Hazardous substance Xn.000 mg/l 500 ml 2 ml/20 A* 10 ml/16 A* 100 ml 10 ml/16 A* 100 ml 200 ml 500 ml 200 ml 18349 2630020 1426810 1415142 1425610 2150342 1218629 1218649 2253929 *) NIST standardised reference material a*) Ampules.000 mg/l VOLUME 100 ml 500 ml 500 ml 100 ml 100 ml 10 ml/16 A* ART. outflow Water hardness.000 mg/l 300 mg/l glucose/ glutamic acid 3. high measuring range All HACH multistandards come in 500 ml bottles HACH single standard solutions—a selection PARAMETER Aluminium as Al* Ammonium as NH3-N Arsenic** as As Barium as Ba* BOD5* CONC.000 mg/l CaCO3 56.1 °dH Total hardness 1. LCA390 LCA555 LCA310 WW DW PW HACH multistandard solutions at a glance APPLICATION Heavy metals in drinking water. low measuring range Heavy metals in drinking water.6 °dH Calcium 500 mg/l CaCO3 hardness 28.3 mg/l PO4-P 400 mg/l SO4 161 mg/l TOC 2833249 2 mg/l NH4-N 25 mg/l COD 4 mg/l NO3-N 2 mg/l PO4 0.2 °dH ART. **) Hazardous substance T.000 mg/l 5. 1417442 189149 15349 1457142 1461142 1486510 PARAMETER Copper as Cu* Fluoride as F-* Hardness as CaCO3* Iron as Fe* Lead as Pb* Manganese as Mn* Mercury*** as Hg* Molybdenum as Mo* Nickel as Ni* Nitrate as NO3-N* Nitrite solution.5 mg/l Cu 1. no.5 x 12. requiring a dilution series to be prepared. BOD TRAK. 7. 714421 1097752 1076416 2616202 DESCRIPTION 6 473-ml brown glass bottles Rubber sleeve stopper Magnetic stirrer bar BOD incubator. OECD biodegradation test for 30 days Measuring range 0-700 mg/l. None of this is necessary when BOD is determined by the manometric method. Measure BOD manometrically The measurement principle is simple. oxygen to be determined. The progress of the test over 5.5 x 30. 1 pkg LiOH Powder Pillows. funnel. 7. When bacteria break down substances contained in the sample. 10 or 30 days The BOD TRAK measuring station is stirrer.68 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. this is costly. 7.85 kg Accessories for BOD TRAK ART. control unit and stirrer with pressure sensors for 6 bottles Methods BOD measurement programmes for 5. 6 473-ml brown glass bottles. The O2 consumption causes the pressure in the bottles to drop. 6 magnetic stirrers. 7. and leave the rest to the BOD TRAK. inside dimensions 42 x 44. grease.com .5 x 61 cm ➔ BOD cuvette test: see page 54 www. 20 °C. they consume O2 and produce CO2. 10 or 30 days can be checked at any time. Cost effective BOD Measuring The conventional route to BOD is very time consuming.hach-lange. NO.7 cm. 2619700 Type Manometric BODn laboratory measurement station. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES BOD TRAK—simple manometric determination of BOD ➔ Simple handling without costly dilution series ➔ Manometric method with no mercury loading ➔ Time savings ➔ Versatile measurement programme for 5. which can be carried out very easily. meter and evaluation unit in one BOD TRAK—the comprehensive measuring station Just add a measured amount of sample and a measured amount of nutrient into the bottles. Art. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. weight 30. 10 days. 50/60 Hz Dimensions. as measurement curves and data can be called up during the incubation. 1 pkg nutrient Powder Pillows Interface 232C for documentation on printer or PC Power supply 0/230 V. connect the pressure sensors. O2. variable Display For graphic representation of the BOD measurement curve Data storage For the measured values Equipment 6 rubber sleeve stoppers. BOD TRAK calculates the BOD value (in mg/l) from the measured pressure. as the generated equivalent amount of CO2 is removed by absorption in LiOH. P/A. space and costs. Where possible. HACH LANGE methods are well designed. They harm health and can disrupt industrial processes. and safely. Many products conform to official standard methods or are approved for legal control measurements. which costs time and money. A long shelf life gives maximum flexibility. Reagents are in liquid form and can therefore be added and mixed dustfree. MPN or paddle tester. Long shelf life and ready for use immediately All reagents and individual tests are ready to use—even sterile consumables can be used immediately. Rapid identification of micro-organisms allows early detection and action can be taken.69 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Fast and reliable detection of micro-organisms Micro-organisms are a risk factor in many areas of life. effective cost reduction and compliance with legal threshold values. whether membrane filtration. DW PW 6 Globally proven methods give reliable results Microbiological methods from HACH LANGE are based on globally accepted procedures. thus saving time. can be carried out simply. Time and cost savings From sampling to the evaluation of the results. . quickly. All procedures. Their effectiveness has been demonstrated all over the world for many years. the reagent holder also serves as the test vessel. Fast and reliable detection of micro-organisms is a prerequisite for process control. reliable and fast E. After the incubation period. coli MPN (MOST PROBABLE NUMBER) Lauryl Tryptose Detection of coliforms . coli or coliforms? With M COLI BLUE24. coli (blue) on filter in 24 h. a change of colour from red to yellow clearly will indicate the presence of a single coliform. P/A (PRESENCE/ABSENCE) Broth Presence or absence of coliforms Broth with MUG Presence or absence of coliforms and E. coli. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES DW PW Fast detection of micro-organisms—for clean drinking and recreational water ➔ Tests and nutrient media ➔ Coliforms and E. coli P/A. fluorescence indicates the presence of E.70 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. coli and coliforms in only 24 hours! Simplified membrane filtration. EPA-approved m-Endo Classic coliform detection m-FC Classic faecal coliform detection m-TGE with TTC Determination of total bacteria count (heterotrophic bacteria) m-HPC Determination of total bacteria count (heterotrophic bacteria) Pseudomonas Broth Detection of Pseudomonas spec. O2. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. HACH LANGE has considerably improved membrane filtration.With MUG Confirmation test for E.com . – Simple handling with pre-portioned selective medium and petri dish complete with filter – Fast results: In only 24 hours Overview of the most important tests and nutrient media MEMBRANE FILTRATION M COLI BLUE24 Detection of coliforms (red) and E. if needed – Pre-dosed for immediate use – Flexible use: individual or with 15 tubes for a 3 x 5 MPN test www. MPN for recreational water and as a confirmation test Benefits: – Standard media – With Durham tubes. coli Brilliant green bile Confirmation test for coliforms Lactose broth Detection of coliforms EC medium Confirmation test for faecal coliforms .hach-lange. coli detection in only 24 hours ➔ Total bacteria count ➔ Pseudomonas aeruginosa Ready-to-use membrane filtration with M COLI BLUE24: reliable detection of E.With MUG Detection of coliforms and E. the simple alternative Faecal contamination? Reliable detection is very simple: just add 100 ml water to the selected liquid reagent in the sterile vessel. count. and evaluate the result. NO. incubate and count. yeasts and moulds on surfaces or in liquids visible. odours? Bacteria are usually to blame. making processes safer and saving costs. But which bacteria? BART testers clearly identify the main culprits. finish! Overview of the tests DESCRIPTION PADDLE TESTERS Total bacteria. corroded pipes. Simply immerse the paddle or press it onto the surface. Simply add the sample to the reagent in the vessel. incubate. incubate. slime-forming. BART testers get the right result Clogged filters. This means that individual limiting values can be specifically monitored. The ready-to-use paddle testers make bacteria. Cost savings Paddle and BART testers indicate the presence of bacteria. 10/pkg 10/pkg 10/pkg 9/pkg 27/pkg 9/pkg 27/pkg 9/pkg 27/pkg each 3/pkg ART.71 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Reliable and accurate monitoring of bacteria and fungi ➔ ➔ ➔ ➔ Slime formation Corrosion Odour Discolouration DW PW 6 Paddle testers for reliable detection Cleaning and disinfection measures cost money and must be checked. They also indicate how many of them are present or their activity. iron-related bacteria Denitrifying bacteria Nitrifying bacteria Fluorescing pseudomonas Heterotrophic aerobic bacteria (total bacteria count) Acid-producing bacteria Micro-algae QTY. Dip the paddle or press it onto the surface. 2610810 2610910 2619510 2432309 2432327 2432409 2432427 2432509 2432527 2434809 9/pkg 7/pkg 9/pkg 27/pkg 9/pkg 27/pkg 9/pkg 9/pkg 27/pkg 2619309 2619407 2432609 2432627 2490409 2490427 2831409 2432709 2432727 . yeast and mould Total bacteria and coliforms Total bacteria and disinfection control BART TESTERS Iron-related bacteria Sulphate-reducing bacteria Slime-forming bacteria Combined package: sulphate-reducing. 00060) and User Manual (BDA318) www.hach-lange. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.200 tests ART. the more toxic it is. NO. O2. LPV321 LTV053 LZV093 DESCRIPTION Liquid-dried luminescent bacteria to EN ISO 11348 part 2 Freeze-dried luminescent bacteria to EN ISO 11348 part 3 LUMIS glass cuvettes. keyword „LUMISTOX“. with free downloads of brochure (DOC032.com.co.uk. for the luminescent bacteria test 200 tests 400 tests 90 tests 1.hach-lange. For official monitoring and day to day analysis The LUMISTOX measuring system is available for a variety of requirements: – For standardised luminescent bacteria tests and all other demanding tasks concerning toxicity – For cost-effective operational analysis LUMISTOX and accessories DESCRIPTION LUMISTOX 300 Luminometer to EN ISO 11348 LUMISTHERM Thermostat 15 °C to EN ISO 11348 LUMISSOFT 4 Computer software with extensive test and sample documentation ART. LCK480 LCK482 LCK487 LCK491 LZP187 LCK 481 More at www. Their viability is indicated by their natural luminescence. www. pkg/638 for the luminescent bacteria test NaCI solution. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW PW LUMISTOX luminescent bacteria test: Toxicity detection in minutes ➔ ➔ ➔ ➔ ➔ Conforms to international EN ISO 11348 standard Long-life preserved bacteria Simple operation Quick results: max. The preserved luminescent bacteria are reactivated before the test is started. The result is available within 30 minutes. Simple and fast The luminescent bacteria test is as simple to carry out as a chemical analysis.52.72 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. test time of 30 minutes Effortless compensation for interferences Work station with LUMISTOX Safe and reliable Does the toxicity of wastewater or environmental samples exceed defined limiting values? Do chemicals or process wastewater samples have to be subjected to a risk assessment? Round robins consistently confirm that the luminescent bacteria test is the most reliable and safest biotest.com .hach-lange. the more the sample inhibits this luminescence. NO. 250 ml. The measured value is determined from several signals.73 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Turbidity measurement to ISO and EPA standards—in the laboratory and in the field Turbidity is an easily obtainable. this means outstanding accuracy and sensitivity over the total measuring range – also at ultrahigh levels of turbidity! 7 Four RATIO detectors White light or infrared 60° 90° 120° The patented RATIO optical system from HACH compensates for interferences with a mixture of transmitted and scattered light 180° . meaningful parameter. as prescribed by EN ISO 7027 for instrument calibration. Comes with an analysis certificate! RATIO optical system compensates for interferences The RATIO optical system in all 2100 series turbidimeters detects and compensates for interference factors such as the intrinsic colour of the sample or fluctuations in the lamp output. in drinking water – In the treatment of wastewater and process water – In the monitoring of municipal and industrial filtration processes – In the monitoring of process water streams – For quality assurance Simple calibration with STABL CAL Turbidimeters are tested and calibrated with formazin suspensions. All instruments are available with the option of an infrared or a white light source in line with ISO or EPA. Reliable turbidity measurement requires the preparation of a formazin standard solution. HACH is the world’s only supplier of stabilised. In practice. and is firmly established in water analysis. quality assurance and process control. Precise and reliable – In detecting the slightest turbidity e. With its STABL CAL range. The 2100 series turbidimeters from HACH combine practical design with standard-compliant measurement technology. directly usable.g. formazin primary standards in different concentrations. Light source Standard RATIO Mode Measuring range Resolution Accuracy Reproducibility Signal averaging Calibration 2100N 2100N IS 2100AN 2100AN IS 4700002 4790002 4700102 4790102 White light Infrared 860 nm White light Infrared 860 nm USEPA 180. 0.1 EN ISO 7027 90°/120°/180° 90° 90°/60°/120°/180° 90°/60°/120°/180° 0.0 – 99.000 NTU 0.000 FNU 0. ± 10 % in the range 4.450 EBC 0. Up to 6 points.01 – 980 EBC 0.000 – 4.001 – 10.000 NTU 0.001–10.01 – 2.000 –10.0 x 30.00 – 9.hach-lange.0 2100AN/AN IS Turbidimeter with integrated printer 2100N/2100N IS—the N series for standard applications – 3-detector RATIO optical system to compensate for interferences – Automatic measuring range switching 2100AN/2100AN IS—the AN series for professional tasks – 4-detector RATIO optical system to compensate for interferences – Wide measuring range up to 10.000 NTU Complete package for turbidity measurement – Maintenance contract complete with extended guarantee for test equipment monitoring – Equipment qualification (EQ) – Adapter for small sample volumes Technical data for 2100N/AN laboratory turbidimeters MODEL Art. 5.001 – 4. see next page www.000 NTU ± 1% or 0. no.000 FNU bzw. 1 in the range 100 –1. 14 sec with signal averaging At least 20 ml Integrated real-time clock RS232C No No Yes Yes 40.001 – 10.1 in the range 10.01 FNU/NTU Can be switched on or off Up to 5 points Up to 5 points Up to 6 points.001 in the range 0.000 NTU 0.001 – 1. 150/230 V AC/50/60 Hz Response time Sample volume Time/Date Interface Integrated printer Dimensions/Power requirements ➔ For turbidity standards and accessories.000 FNU 0.999 FNU/NTU.000 NTU ± 2 % in the range 0 –1.000 NTU ➔ Simple calibration ➔ Intuitive operation ➔ For opalescence in line with Pharm.2 cm (L x B x D). Eur. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.001 – 1.1 EN ISO 7027 USEPA 180.99 FNU/NTU 0. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Wide turbidity measurements in the laboratory ➔ With infrared or white light in line with ISO and EPA ➔ Wide measuring range thanks to RATIO optical system: 0.000 NTU.000 NTU. User method User method with up to 8 points with factor < 7 sec. O2. ± 5 % in the range 1.com .9 FNU/NTU.5 x 14.74 LABORATORY ANALYSIS 2_OVERVIEW 3_pH.001– 0.01 in the range 1. 10. 01 – 1.hach-lange.hach-lange.01 – 1.9 1 in the range from 100 –1. The 2100P model conforms completely to the guidelines of the USEPA 180.2 x 9.99 0.52.uk.00641) and 2100P ISO (DOC022.00620) and User Manuals for 2100P (DOC022. with free downloads of brochure for 2100P ISO (DOC062.45 kg (2.1 in the range from 10. keyword “2100 Turbidity”. 2100P portable turbidimeters MODEL Art.01 in the range from 0.000 ± 2 % of the reading plus scattered light < 0.01 FNU/NTU Can be switched on or off 4-point calibration.7 kg in case with accessories) 0 – 50 °C 2100P ISO 4474002 Infrared (860 nm) EN ISO 7027 90/180 ° 0. automatic 6 sec LCD At least 15 ml 22. even in the most difficult surroundings. calibrating and measuring in the field.75 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Reliable and robust turbidimetry in the field ➔ Standard-compliant technology ➔ Precision due to RATIO optical system ➔ Simple to operate ➔ Reliable and robust ➔ Fully equipped for on-site operation WW DW PW 7 ISO with white light or infrared In order to be able to compare turbidity values reliably.52. www. no.5 x 7.000 FNU Accuracy Scattered light Reproducibility Signal averaging Calibration Response time Display Sample volume Dimensions Weight Operating conditions More information at www. which protects the instruments perfectly.co. traceability to international standards is necessary. The non-adjustable optical system is enclosed in high-impact ABS plastic. and are factory calibrated.0 – 99.00630) .01– 9.9 cm (L x W x D) 0.02 FNU/NTU ± 1 % or 0.1 90/180 ° 0. Rough terrain and difficult samples—no problem The RATIO optical system guarantees precise measurement results right across the measuring range – even when samples are turbid or ultraclear.52. Fully equipped in the field The easy to use 2100P and 2100P ISO turbidimeters can be powered by mains or batteries. In addition. the practical carrying case holds everything needed for transporting.1.com. The 2100P ISO was designed to conform with EN ISO 7027 (860 nm IR LED). Light source Standard RATIO-Mode Measuring range Resolution 2100P 4650000 White light USEPA 180.000 NTU 0. 4.30. 7. pkg/6. 6.000. 100. 100 ml.1. 1. IV with Pharm. 5. cuvette cleaning cloth. 200.500 NTU/FNU 2659505 STABL CAL 100 ml bottle set: < 0. 1.000 NTU/FNU 246149 ACCESSORIES Round cuvettes 13 mm. 1. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW STABL CAL standards and accessories for measuring turbidity ➔ Durable. www. pkg/494 LYY621 Stopper for LYY621 round cuvette. high pressure 4745100 Cuvette adapter for 12 to 13 mm round cuvettes 3033400 Cuvette adapter for 16 mm round cuvettes 3033500 Cuvette adapter for 19 mm round cuvettes 3033600 Silicone oil. Silicone oil.500 NTU/FNU 2659500 Calibration kits for 2100N/2100N IS STABL CAL vial set: < 0.00646JUN04) www.1. ➔ Opalescence conforms with Pharm.000 NTU/FNU 246142 STABL CAL 500 ml bottle: 4. 30 NTU/FNU 2897100 STABL CAL 100 ml bottle set: < 0. ready-to-use stabilised formazin primary standard. stable standard suspensions in bottles or sealed vials ➔ Immediately ready for use.com . pkg/6. 4.000.0) Spare cuvettes with screw cap. 4. 3.10. 4. pkg/5 rolls 4709000 Power pack for 2100P/P ISO.1.0. 7. 200. no dilution needed ➔ Preparation of a formazin stock solution is no longer necessary Two simple methods: Either insert the reusable vials directly into the instrument or use standard solution from bottles. 1. 800 NTU/FNU 2659410 STABL CAL 500 ml bottle set: < 0. 20. with free downloads of brochure (DOC062. 3.000. 2100AN/AN IS 2896642 STABL CAL 100 ml bottle: 4.1. 100. Eur.00 NTU/FNU. 5. 800 NTU/FNU 2659405 STABL CAL 100 ml bottle set: < 0. for 2100P/2100P ISO 2434706 Flow-through cell set.52. Eur.52. 20.500 NTU/FNU 2659510 STABL CAL 500 ml bottle set: < 0. for 2100AN/2100AN IS 2084900 (also for visual methods in conformity with Pharm.000 NTU/FNU 2662110 STABL CAL 500 ml bottle set: < 0. 20.000. 1. NO.1.hach-lange.1.uk. 1. 2714600 including 4 100 ml bottles: 0. 20. 20. 18. 0.1. 30 NTU/FNU 2897200 Stock suspension for measuring opalescence in conformity with Pharm. 800 NTU/FNU 2659400 STABL CAL standard kit for monitoring fine turbidities. 20. 4.000. III.000. 2100AN/AN IS with certificate STABL CAL vial set: < 0. 100.hach-lange.1. 230 V AC/6 V DC 4608000 More information at www.000. keyword „STABL CAL“.000.0.50.0 STABL CAL standards and accessories for measuring turbidity and opalescence STABL CAL standards ART. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.000. Eur. 20. stable for 2 years after preparation Calibration kits for 2100AN/2100AN IS STABL CAL vial set: < 0.76 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. 20.1.000 NTU/FNU 2662100 Calibration kits for 2100P/2100P ISO STABL CAL vial set: < 0. pkg/1 EYG044 Spare cuvettes with screw cap. stable for at least 6 months Set of reference suspensions I. 18.00222) and user manual (DOC022. manual. 200. low pressure 4744900 Flow-through cell set. II.hach-lange. O2. instructions.1. 5.co. 20. 1. 200.1. Eur. 4. 5.000 NTU/FNU 2662105 STABL CAL 100 ml bottle set: < 0. 0. 6. 7. 200.com. 15 ml bottle 126936 Cuvette cleaning cloth 2687300 Sample degasing kit 4397500 Printer paper for 2100AN. 200. 000 mg/l 0 – 800 mg/l * Digital titrator and accessories in a case. The titrant is added by turning a button.000 mg/l 2.000 mg/l 20 – 400 mg/l 1– 200 °dH PARAMETER Hardness (total) Hypochlorite Iron Nitrite Org. where speed and simplicity are of the essence.000 mg/l 10 – 4.000 mg/l 10 –1.000 mg/l 10 – 4. buffer solutions and delivery tubes. When a colour change occurs. quickly and easily.400 mg/l 1–100 mg/l 0 –100 ppt 0 –1. it is popular in the field. e. accuracy ± 1% ➔ Test sets with cartridges and colour indicators for the digital titrator: see page 52-53 . acids Oxygen Salinity Sequestrants Sulphite MEASURING RANGES 1– 200 °dH 50 –150 mg/l 10 –1. delivery 800 digits/ml (1. mains-independent ➔ ➔ ➔ ➔ 40 methods available Easy handling Reliable results Wide range of accessories 8 Fast and simple Titration is a very widely used analysis method. resealable cartridges. anywhere.5 – 10.77 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Titration is made easy with the digital titrator ➔ Ready immediately. into which compact cartridges with concentrated titrant can be inserted. cartridges. As well as in the laboratory. order no.* PARAMETER Acid/base Acidity Alkalinity Carbon dioxide Chloride Chlorine (free) Chlorine (total) Chromate Hardness (Ca) 1690001 MEASURING RANGES 1– 4. Digital titrator and cartridge with delivery tube Titrants for digital titrator. Everything is included in the carrying case: digital titrator. the added volume can be read directly and used to calculate the result. The digital titrator can be held by hand or in a laboratory stand. each of which is good for up to 100 titrations.000 mg/l 100 – 2.500 mg/l 100 – 2. No glass burette needed The digital titrator is a precise dispenser. Fully equipped for 40 methods Parameter-specific titrants for more than 40 methods are available in easily exchangeable. The sturdy digital titrator and its practical accessories provide reliable data.000 mg/l 0 – 3 mg/l O – 70. * 1690001 Art.g. for cooling and boiler water. No.25 µl/digit). 5 ml 1 inch. plastic. quartz glass. NO. with cap 1 inch. with rubber stopper 10 mm. 17. glass. glass. O2. 160 µl 10 mm. with cap. glass. 1. with lid.uk www. glass. 25 ml. 3/pkg 10 mm. 10 ml 10 mm. with stopper 1 inch. 25 ml 1 inch.com .5 ml 50 mm. 100/pkg 50 mm. 3. blackened 50 mm. quartz glass 50 mm.5 ml. 100 µl ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ART. quartz glass 50 mm.000/pkg 10 mm.78 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. 25 ml. special optical glass 50 mm. polystyrene. spectrum 170-2. matched pair. with lid. 6/pkg 1 inch. quartz glass. quartz glass. 370 µl 3 mm. matched pair. LCW906 LZP334 LZP168 LZP335 LZP336 LZP269 LZP169 LZP341 EBK019 LZP045 LZP332 LZP331 LZV008 LZP167 LZP333 2495402 2095100 2122800 2427606 2629500 2629250 2624450 5913700 2665902 2612602 2410212 2401906 5940506 4864302 2624410 A24209 LZV510 LZV649 LZV638 ➔ More information about the DR 2800. quartz glass 20 mm. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD. matched pair.5 ml. for flow-through cell kit 5940400 1 inch. 6/pkg 10 mm. glass. 10 ml. glass. with cap. 12/pkg 1 inch. 2/pkg 10 mm. special optical glass 50 mm.hach-lange. with lid. special optical glass 50 mm. quartz glass.hach-lange. 25/pkg. quartz glass. 10/pkg 10 mm. 1. glass. special optical glass.hach-lange. 450 µl 50 mm. 10 ml. quartz glass 50 mm.700 nm 10 mm. quartz glass 1 inch. DR 5000 and XION laboratory photometers: see page 34-37 www. special optical glass 10 mm. 3. quartz glass. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Accessories I: glass cells for laboratory photometers SA CA 30 / LA DA S XIO S 20 A 1 00 0 N DR 28 DR 00 50 00 DESCRIPTION Round cells Flow-through cell Flow-through cell Flow-through cell Flow-through cell Semi-microcell Semi-microcell Plastic semi-microcells Plastic cells Rectangular cell Rectangular cell Rectangular cell Rectangular cell Rectangular cell Rectangular cell Rectangular cells Rectangular cells Round cell Round cells Disposable rectangular microcells Rectangular cell Rectangular cell Rectangular flow-through cell Rectangular cells Rectangular cells Disposable rectangular cells Round cells Round cells Plastic cells Rectangular cell Rectangular flow-through cell Rectangular flow-through cell Rectangular flow-through cell Rectangular flow-through cell LA PHOTOMETER 11 mm. 6/pkg 1 inch.com Order simply and quickly ! www. special optical glass 20 mm.5 ml 1 inch. glass. with measurement window for 10 mm path length. 17.co. matched pair. special optical glass. 51000 DRB 200 dry thermostat HT 200S high temperature dry thermostat LTV082. EPA 1 heating block with 11 compartments: 9 x 16 mm diameter.99. Available as a single or double block with different compartments for round cuvettes and reaction vessels.79 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Accessories II: Thermostats—precise temperature control WW DW PW 8 Dry thermostat LT 200 High temperature thermostat HT 200S Perfectly matched HACH LANGE measurement systems For both standard and customised digestions.99.99. the LT 200 is the ideal complement to photometric measurement instruments.99. LTV082. Benefits include: simple operation. ISO.30001 LTV082. 2 x 20 mm diameter 1 heating block with 15 compartments: 15 x 16 mm diameter 2 heating blocks with 25 compartments: 21 x 16 mm diameter. 1–480 minutes digestion time. total nitrogen.40001 LTV082. the HT 200S thermostat heats up to 170 °C and then cools down again.42001 LTV082. heating time from 20 – 150 °C: 10 minutes ± 1 °C in conformity with EN. 165 °C. For time-saving 15-minute digestion for COD. 100. three standard programmes (100 °C/148 °C/high temperature) and nine freely selectable programmes. phosphate and heavy metals. heating phase: max. 2 x 20 mm diameter 2 heating blocks with 25 compartments: 21 x 13 mm diameter.99.10002 LTV082.23000 LTV082. 8 minutes.44001 LTV077 .-NO. 13 minutes.99. heating time from 20 to 148 °C: 10 minutes ± 1 °C in conformity with EN. 105. 1–480 minutes digestion time. 4 x 20 mm diameter 2 heating blocks with 30 compartments: 30 x 13 mm diameter 2 heating blocks with 20 compartments: 12 x 13 mm diameter.g.21002 LTV082. great programming flexibility and reliable operation. ISO. freely selectable: 37–165 °C. freely selectable: 37–150 °C. 4 x 20 mm diameter 2 heating block with 30 compartments: 30 x 16 mm diameter 1 heating block with 12 compartments for 13 mm diameter. programmed for 40. EPA 1 heating block with 11 compartments: 9 x 13 mm diameter.99.99. programmed for 100. with the help of the HT 200S. Technical data LT 200 dry thermostat DESCRIPTION With compartments for 13 and 20 mm diameter. 148 °C. digital display for time (5–240 minutes) and temperature (40–150 °C) ART. active sample cooling: max. The HT 200S—for highly efficient digestion In just minutes. 8 x 20 mm diameter With compartments for 16 and 20 mm diameter. This saves valuable working time during and after the digestion! E. COD results can be obtained in just 35 minutes. 150. 0 ml) For piston pipette (1.0–5.500 rpm for homogenising and for enriching AOX 3 rods for LYW977 laboratory magnetic stirrer Shaker/fan combination for accelerated expulsion of inorganic carbon for TOC cuvette tests LCK385/386/387 0.0 ml) and electronic pipette BBP087 For checking pipettes BBP078/065/164/087 (for 4 determinations) For 16 LANGE round cuvettes or rectangular cuvettes (10 mm) Accurate to the second. manual ART.0 ml 0. 5/pkg For TOC tests LCK 380/381. with exact dispensing for all tests Software for data transfer from instrument to PC Accessories—a selection DESCRIPTION Chloride elimination set Membrane filtration set (1.hach-lange. for nitrate analysis Consisting of 50 special filter membranes (1.45 µm) and disposable syringe (10 ml) For the digestion of complex.2–1.hach-lange.uk. O2.g. flexible. with clip and magnet Uvex. languages: German/English/French/Italian/Spanish.0–5. for short periods (0–24 hours).2 µm) and disposable syringe (10 ml) Consisting of 50 special filter membranes (0.0ml 1.45 µm) CRACK SET Reaction vessels Powder dispenser Screening test SwifTest SwifTest Chloride test strips Laboratory magnetic stirrer Magnetic stirring rods TOC-X5 shaker Electronic pipette Piston pipette Piston pipette Pipette tips Pipette tips Pipette test set Cuvette stand Digital laboratory timer Protective goggles Test solution set Test filter kit HACH LINK HACH DATATRANS For removing interfering chloride loads. www.2–5. NO.hach-lange. green/purple. cable. colloidal or undissolved metals With screw top.com www.com . chlorine test LCW 510 from LANGE For the detection of interfering organic sequestrants Powder dispenser for HACH free chlorine test Powder dispenser for HACH total chlorine test Meas. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.80 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. to DIN 58211 For checking the photometric accuracy of measurement systems For checking DR 2800 and DR 5000 photometers Software for transferring data from HACH photometers via an interface to a PC Software for transferring data from DR 2800 and DR 5000 photometers via a USB interface to a PC.2 µm) Membrane filtration set (0. e. LCW925 LCW904 LCW916 LCW902 LZP065 LCW912 LCW907 2802300 2802400 2751340 LYW977 LYW064 LQV148. pipettes and much more Specific sample preparation for tests Variable piston pipettes.0ml For piston pipette (0.co.2–1. complete with CD.99. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES WW DW PW Accessories III: Sample preparation. range 300–6.000 mg/l as pre-test and for detecting interference with COD/nitrate tests 0–1. 00001 BBP087 BBP078 BBP065 BBP079 BBP068 LCA722 LYW915 LZC902 EZZ042 LZP181 LZV537 4966500 LZY274 ➔ For quality assurance products: see page 66 ➔ More accessories: see www. 00.40000 LZV570 LZV571 . USB ports are now a feature of the DR 2800 and DR 5000 spectrophotometers too. serial Barcode scanner. LICO. NO.30000 LQV134. application software ART.10000 LZP180 LZV261 LZV566 LZV582 LZV568 LQV134. ➔ More information about the DR 2800 and DR 5000 spectrophotometers: see pages 34—36 Space saving printer There may not always be a PC available beside the measuring instrument. DR 5000 and XION spectrophotometers: see pages 34—37 Technical data and order information DESCRIPTION USB ink jet printer Measured value printer DPU414 measured value printer. DR 5000. and to download updates to the spectrophotometers more smoothly and reliably than ever before. CADAS and XION laboratory photometers enable samples to be identified automatically from their barcodes.81 ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Accessories IV: Documenting data WW DW PW 8 Simple data transfer using USB technology Compact thermal printer documentation The external barcode scanner can be connected to the photometer USB technology—the simple and fast way of transferring data USB technology has enormously simplified the transfer of data between systems. CADAS and LICO photometers For DR 2800 and DR 5000 photometers For USB port (English keyboard layout) 128 MB data storage device for data transfer With 36 x 30 ml sample carousel. USB Compact keyboard USB memory stick Sample changer for GANIMEDE automatic laboratory analyser Additional software for DR 5000 Spectrophotometer HP DeskJet 6540 for DR 2800 and DR 5000 photometers (DIN A4 paper) For all current HACH instruments Thermal printer with parallel cable for XION and GANIMEDE photometers Thermal printer with serial cable for LICO and LASA photometers For DPU414 measured value printer For XION.99. application software Drinking water analysis. serial Printer paper Barcode scanner. It automatically recognises individual and standard barcodes. The external barcode scanner is connected to the photometer. e. automatic needle rinse With 53 x 15 ml sample carousel. USB ports or a USB memory stick are used to transfer measured values. or there may not be enough space in the laboratory for a conventional printer. They make the processing of analytical data a lot easier. parallel DPU414 measured value printer. automatic needle rinse MEBAK brewery analysis. In these circumstances.g. space-saving compact printers enable the results to be documented next to the instrument. Instant scanning of samples The DR 2800.00. ➔ More information about the DR 2800. LYW368 A70P020 LQV144. to LIMS.99.00000 LQV144. slider condenser for phase contrast applications. optical alarm on large. good image levelling and chromatic correction. www. for O2. determination method fully automatic or with set time of 0. capacity 300 g. CONDUCTIVITY 4_PHOTOMETERS 5_REAGENTS 6_BOD.1—99 min See above. thermometers and other analysis accessories are available on request. lots of upgrade options High-performance laboratory microscope for unparalleled optical brilliance and ergonomics. shortest measurement time from 1. microscopes. except capacity 45 g with 1 mg resolution. standard 1. together with all their settings. capacity 35 g with 1 mg resolution. sewage treatment sludge. indicates that different configurations are available.82 LABORATORY ANALYSIS 2_OVERVIEW 3_pH. high contrast imaging quality with universal condenser and HI PLAN phase contrast objectives for high contrast. rugged design and large selection of accessories: all-glass optics. O2. no.g.0 g initial sample weight.1—99 min SM1349-0001 LEICA CME microscope LEICA DME microscope SM0881108 SM11888133-0001 LEICA DM 1000 microscope SM3240303 SMTE313S ACCULAB balance SARTORIUS TE313S balance SARTORIUS MA35M moisture analyser SM324035M SM324045Q SARTORIUS MA45Q moisture analyser ➔ An “X” in the art. ➔ More information about gas detectors. H2S. 0—100 vol% measuring range available for combustible gases. e. by the meter – Acoustic (90 dB. determination method fully automatic. CH4. MICROBIOLOGY 7_TURBIDITY 8_ACCESSORIES ➔ Laboratory automation: see Chapter 9 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Accessories V: Gas detectors. resolution 0. NO. upgradable with fluorescence axis Laboratory scales with illuminated LCD.2% (sample < 5 g) or ± 0. SM12403X NAME GFG POLYTECTOR G 750 gas detector DESCRIPTION – Light and compact 6-sensor multi-gas detector with alarm functions and simultaneous display of all measured gas hazards. optional ISO/GLP-compliant documentation. microscopes.05% (sample > 5 g). highly visible. as well as for oil immersion and darkfield applications High-performance laboratory microscope for brilliant.001 g Electronic precision balance with 7-segment display. RS-232-C interface. only one key in normal mode – Dimensions: approx. stability range recognition and 4 selectable balance filter levels. also with high throughput.001 g Compact meter for fully automatic determination of moisture content or total dry solids. LED – Simple to operate. semi-automatic 1—20 mg/24 sec or with set time of 0. ideal for the bacteriological laboratory. capacity 310 g.com . are simply plugged in and are immediately recognised. with condenser and HI PLAN phase contrast objectives. 90 x 210 x 60 mm Basic laboratory microscope with excellent image quality. infrared CO2.A. resolution 0. 770 g. balances. accuracy ± 0. e. ATEX approved – Modular plug-on system for easy adjustment – Intelligent sensors.hach-lange.25 N. 30 cm) alarm. balances High performance—the LEICA DM 1000 laboratory microscope Portable—the ACCULAB VICON scales from SARTORIUS Sensitive—the GFG POLYTECTOR G 750 multi-gas detector with 6 sensors Analysis accessories—a selection ART.g. automation is the answer.9_LABORATORY AUTOMATION ➔ Laboratory analysis: see Chapter 2-8 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 83 Automated analysis for individual samples and sample series When more samples have to be analysed without taking on additional personnel or expanding the laboratory. This applies to drinking water laboratories. large sewage treatment plants as well as electroplating facilities food. industrial quality control. HACH LANGE can provide you with reliable solutions for different methods and parameters. pharmaceutical and petrochemical sectors. for up to 120 samples per hour ➔ See page 89 AP 300 DISCRETE Analysers with dual pipette system for up to 300 samples per hour ➔ See page 88 . 9 TOC/TN analyser with an especially wide measuring range ➔ See page 84 TITRALAB titration systems now with RFID—for simple and reliable GLP ➔ See page 86 GANIMEDE Analysers with patented flash digestion for total N and total P ➔ See page 90 QUICKCHEM 8500 FIA analyser with ready-touse reagents. 84 9_LABORATORY AUTOMATION WW TW TOC-TN analysers—rugged. thanks to the wide dynamic measuring range The pneumatic port corresponds to the particle test and conforms with ISO 8254 and DIN EN 1484 Autosampler with large diameter needle for high particle tolerance Chemiluminescence detector for ISO compliant TN determination Getting the right result TOC and TN. highly accurate ➔ Variable: TOC with high temperature digestion or UV digestion ➔ Reliable: ISO compliant TOC and TN determination ➔ Flexible: TOC solids analysis in two variants for series of samples and single samples ➔ Versatile: suitable for a wide range of wastewater. through the pneumatic port. reliable. drinking water. process water and quality control applications. The furnace temperature of 950 °C and the optimised catalyst packing enable particle containing samples as well as the most poorly digestible substances to be oxidised completely. High temperature digestion The direct injection with a 700 µm needle guarantees excellent particle tolerance. without time consuming preparation of standard solutions.com . without tubes or valves. The heat to which the needle is subjected during the analysis ensures that there is no sample carryover.hach-lange. IL 550 TOC-TN analyser for the determination of both TOC and TN www. The direct injection is carried out septum-free. The long service life is assured even when it is exposed to aggressive samples. which hermetically encloses the syringe. particles and salt containing samples— all of them are no problem for the IL 550 TOC-TN analyser. liquids and solids. The variable injection volume enables calibration to be carried out volumedependent. for which samples of up to 20 ml are injected. 9 High energy—UV digestion at 187 and 254 nm Overview of TOC-TN analysers INSTRUMENT TYPE TOC measuring range (NDIR) TN measuring range (CLD or ECD) Method Parameter TC/TOC/NPOC/TIC.300 °C) Simultaneous measurement of TOC and TN Operation with autosampler Stirring at current sample position Simultaneous purging and measurement for determining NPOC Dimensions of basic TOC instrument (H x W x D) ➔ Accessories for TOC-TN analysers on request IL 550 TOC-TN 0. During UV digestion the direct contact between the sample and the UV source ensures efficient oxidation with excellent recovery and reproducibility.1–100 mg/l HT digestion up to 950 °C ● IL 500 TOC 0.85 ➔ Laboratory analysis: see Chapter 2-8 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW IL 500 TOC including autosampler with two-needle technology Highly sensitive: TOC with UV persulphate digestion The IL 500 TOC analyser is ideal for the low measurement range.2–30. and incurs minimum operating costs.000 mg/l 0. the doubleneedle technology allows purging and measurement to be carried out simultaneously. The instrument has an exceptionally low maintenance requirement. If an autosampler is connected.000 mg/l 0.000 mg/l UV persulphate digestion ● Direct injection Optional Optional Optional Optional ● Injection through septum Optional Optional Optional Optional ● Flow injection Optional ● 512 x 540 x 530 mm 512 x 540 x 530 mm 512 x 492 x 464 mm . functions without a catalyst. difference or purge method Signal optimisation with VITA Sample introduction DFS 950 solids module (950 °C) HSC 1300 solids module (1.002–10.05–30.1–100 mg/l HT digestion up to 950 °C ● ● IL 530 TOC-TN 0. thus saving time. food – Free and total SO2: wine. etc. thus avoiding any possibility of contamination and eliminating rinsing steps. fruit juices Environment and water – pH and alkalinity – Total hardness – Chloride – COD Chemical and electroplating – Acid-base determination in aqueous and non-aqueous media – Imposed and zero-current redox determination – Complexometric determinations – Silver and precipitation determinations. ISO3771 – Bromine index and bromine number conforms with ASTM D1491. petrochemical – TAN/TBN in conformity with ASTM D664. other milk products – Ascorbic acid: fruit juices. Cable-free and touch-free. conforms with GLP The new titration systems with cable-free RFID technology It is now simpler than ever to be 100% reliable. together with all important characteristic values In just seconds the whole burette stand (with the burette and all titrant conducting elements) can be detached. milk – Chloride: milk. D1159. fruit juices.com . as can the TITRALAB 965 with the double burette module (not shown) At a glance—the large colour display shows the titration curve instantly. first use. The titrants are changed together with all their conducting elements. D2896. latest calibration. conforms with ASTM D3227 ➔ Simple burette change by hand ➔ Fast titrant change with minimum rinsing time ➔ Intuitive handling through self-explanatory menus and simple method programming with a large display Upgradable at any time—TITRALAB 960 with the single burette module can be expanded with up to four additional modules. Ready to use complete titration systems for: Food and beverages – Total acid content: wine. docked in the reagent bottle to save space and stored in the rack www. the system identifies the inserted burette automatically. butter. D7210 – Hydrogen sulphide and Mercaptans.hach-lange. The reliability of the measured values and the traceability of reagents can be enormously simplified with RFID. with all the necessary data – reagent name.86 9_LABORATORY AUTOMATION WW DW PW TITRALAB—Automatic titration for single and multiple samples ➔ RFID technology for automatic reliable reagent traceability. vinegar. co. PC software 1 2 1 1 1 More information at www.hach-lange. with free downloads of brochures and User Manual as well as information about ordering TITRALAB workstations. these systems are distributed by specialised partners. 9 Overview of the TITRALAB family TITRALAB Burettes Number of burettes Additional burettes Burettes exchangeable with RFID identification Techniques pH/mV measurements Endpoint titration Inflection point titration pH-stat titration Volumetric Karl Fischer titration Conductivity measurements ISE measurements Titrant addition techniques Continuous dynamic Incremental monotonic and dynamic Peripherals Electrode inputs for Indicator electrodes Reference electrodes Polarised electrode 840/845 1/2 854/856 1/2 865 870 960/965 980 2 ● 55 1 2 2 1/2 4 with 2 ABU 52 or ABU 62 double burettes ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Samplers. printer. ➔ In some countries.87 ➔ Laboratory analysis: see Chapter 2-8 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Wide selection of electrodes for complete titration systems With more than 60 years of manufacturing experience. At both workstations. Low cost accessories and high sample throughput The SAC90 sample changer (see picture above) processes up to 126 samples— day and night. The TITRAMASTER 85 PC software displays and manages the data from up to seven titrators. reagents and electrodes. balance. keyword “TITRALAB”. only passing over already titrated samples.hach-lange. .com. RADIOMETER ANALYTICAL stands for exceptional electrode quality. the high-resolution burette guarantees safe and reliable measurement results with solid and liquid samples.uk. The unique RED ROD technology (see picture above) guarantees fast response times and long-term reliable and reproducible results. Volumetric Karl Fischer titration for water analysis Complete Karl Fischer workstations are available on their own (TITRALAB 55) or combined with a potentiometric titrator (TITRALAB 980). the electrodes are moved to the rinse beaker by a safe route. To avoid any contamination. Your HACH LANGE contact will provide you with further information. www. 52921 52918 52926 52925 52920 52919 52923 www. acidstabilised samples Chloride Cyanide Nitrate.00 mg/l 1. ortho MEASURING RANGE 0.04—0.00 mg/l 0.0—300 mg/l 0.com . D-10-107-06-1-A D-10-107-06-1-B D-10-117-07-1-A D-10-204-00-1-A D-10-107-04-1-A D-10-107-04-1-B D-10-115-01-1-A ART.00 mg/l 1.03—2.00—50. dilutions and samples Ready-to-use reagents for the AP 300 DISCRETE analyser PARAMETER Ammonium.75 mg/l 0. non-acidstabilised samples Ammonium.hach-lange.00 mg/l METHOD Berthelot Berthelot Thiocyanate Pyridine barbituric acid Sulphanilamide Sulphanilamide Molybdate METHOD NO.03—2. NO.015–1.0 mg/l 25.0 mg/l 1.10—2.00—20.75—20.0 mg/l 0.50 mg/l 0. nitrite Nitrate.00—20. nitrite Phosphorus.02—0.88 9_LABORATORY AUTOMATION DW AP 300 DISCRETE analyser—compact ion analysis ➔ Flexible use—several parameters per sample. simultaneously ➔ Cost savings—low reagent volumes from 10 to 300 µl ➔ User friendly—intuitive menu guidance and preprogrammed methods ➔ High measurement frequency—up to 300 tests per hour ➔ Reliable results thanks to dual pipette system AP 300 DISCRETE: Fully automatic ion analyser for environmental analysis. complemented by high quality.0 mg/l 0. ready-to-use reagents Incubator unit Rinse station Reagent pipette Sample pipette Reagent bottle Turntable for standard solutions. inline Sulphide. anionic Total nitrogen. Twenty years of practical experience went into the development of QUICKCHEM 8500. inline Total phosphorus. that process large numbers of samples. Method manuals (in English) available on request . The comprehensive measuring ranges for a wide range of parameters. inline DIGESTION METHOD UV high temperature Gas diffusion. then condensation Single or double extraction with chloroform UV persulphate UV persulphate Distillation Ammonium Nitrate Nitrite Chloride Chromium Cyanide Silica Aluminium Iron Manganese Phosphate pH ● ● ● * Alternative: external sample preparation with the MICRODIST digestion system—a heating block which can accommodate 21 prepared digestion tubes. make FIA an essential analysis tool. inline Phenol.WASTEWATER.89 ➔ Laboratory analysis: see Chapter 2-8 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 Efficiency and high sample throughput with FIA—QUICKCHEM 8500 ➔ Time-saving thanks to method-specific. WW DW PW ➔ Immediately ready for use ➔ Method changeover in minutes ➔ Automatic elimination of gas bubbles in the sample ➔ Alarm function to detect for leaks ➔ Multilingual operating software 9 QUICKCHEM 8500—flow injection analysis for 120 samples per hour QUICKCHEM methods without sample preparation PARAMETER READY-TO. More information available on request ➔ More than 400 standard and other methods available. ready-to-use reagents Maximum productivity The FIA technology significantly improves traditional methods such as SFA (segmented flow analysis) and has been developed further and proved to be a cost effective analysis method for water and environment laboratories. for all types of water. SEA WATER USE REAGENTS DRINKING AVAILABLE WATER ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● QUICKCHEM methods with integrated sample preparation* SOIL PARAMETER Cyanide. inline Detergents. 5-150 mg/l TNb. GCA200 ➔ Sample changer for GANIMEDE: see page 81. 1 sample changer 230 V/50 Hz (optional 110 V) 5. more accessories available on request www. GCA100 Technical data for GANIMEDE N Measurement method Measuring range Repeatability Measurement wavelength Calibration Sample turntable Interfaces Power requirement Colour display Reagent set Analogous to EN ISO 11905-1 0. IR interface GANI CHEM P for automatic phosphate analysis. article no.01-3. Reliable results in minutes— for efficient digestion The integrated high temperature digester.8 mg/l PO4-P At 1 mg/l: ± 2% 880 nm Autom. easy to handle GANI CHEM reagents can be used for up to 100 determinations. consisting of a sample changer. 2-point. makes it possible to work flexibly at different measuring stations. measuring range 0. article no. measurement range 0. 2-point. IR interface GANI CHEM N for automatic determination of total nitrogen. Used reagents are safely and conveniently disposed of by HACH LANGE. Sample data is acquired via the barcode scanner or a PC and processed by the control unit.90 9_LABORATORY AUTOMATION ➔ Laboratory analysis: see Chapter 2-8 ➔ Samplers: see Chapter 10 ➔ Process measurement technology: see Chapter 11-20 WW DW PW Automatic laboratory analysers with integrated digestion—GANIMEDE P and N ➔ ➔ ➔ ➔ ➔ Results in minutes for total P and TNb Integrated fast digestion Ready-to-use reagents Portable control unit Simple handling Specific analysis units with integrated digestion or total P and TNb Flexible. optional standard series 36 x 30 ml 1 serial. High quality. analogous to EN 1189 (phosphate) or ISO 11905-1 (nitrogen). with fast cooling feature.hach-lange. 1 parallel. GANI CHEM ready-to-use reagents The time consuming preparation of reagent solutions is a thing of the past. Technical data for GANIMEDE P Measurement method Measuring range Repeatability Measurement wavelength Calibration Sample turntable Interfaces Power requirement Colour display Reagent kit Analogous to EN 1189 0. Even complex phosphate or nitrogen compounds are completely digested and processed in four to seven minutes. intelligent data management The GANIMEDE system. delivers precise and quick results. 100 determinations.8 mg/l P.5 –150 mg/l TNb At 10 mg/l: ± 2% 210 nm Autom. 1 sample changer 230 V/50 Hz (optional 110 V) 5.7 inch. optional standard series 36 x 30 ml and 53 x 15 ml 1 serial.7 inch. The cordless control unit communicates with one or both analysis units.com . control unit and analysis units with integrated digestion for N or P. 1 parallel. 100 determinations.01– 3.
Copyright © 2024 DOKUMEN.SITE Inc.