Gulf Coast-Cool Nights Spa Manual

March 26, 2018 | Author: Eulalio Omar | Category: Hyperthermia, Electricity, Building Engineering, Wellness, Nature


Comments



Description

COOL NIGHTS SERIESOWNER’S MANUAL 11620 - 54th Street North Clearwater, FL 33760 (727) 573-9888 www.GulfCoastSpas.com Premier Spas and Custom Wood Products TABLE OF CONTENTS 2 TABLE OF CONTENTS……………………………………………………………………………………………………………….2 3 INTRODUCTION……………………………………………………….………………………………………………………………3 3 IMPORTANT SAFETY INSTRUCTIONS..……………………………………………….………………………………………….3 5 INSTALLATION……………………………………………………..………………………………………………………………….5 6 ELECTRICAL SPECIFICATIONS…………………………………………………………………………………………………….6 9 STARTUP PROCEDURES…………………………………………………………………………...……………………………….9 10 CHEMICAL-FREE AQUACLARA WATER MANAGEMENT SYSTEM………………………………………………………….10 SARASOTA INSTRUCTIONS……………………………………………………………………………………………………. 11 ONE-TOUCH CONTROLS (Cape Haze, Englewood, Rotunda and Boca Grande)…..…………………………………..1115 16 PROGRAMMING FILTER CYCLES (Cape Haze, Englewood, Rotunda and Boca Grande)………………………………..12 17 FREQUENTLY ASKED QUESTIONS……………………………………………………………………………………………...13 18 TROUBLESHOOTING GUIDE….…………………………….…………………………………………………………………….14 19 MAINTENANCE and CARE…………………………………………………………………………………………………………15 20 SHUTDOWN PROCEDURES………………………………………………………………………………………………………16 21 SARASOTA SCHEMATIC…………………………………………………………………………………………………………..17 22 CAPE HAZE SCHEMATIC………………………………………………………………………………………………………….18 23 ENGLWOOD SCHEMATIC…………………………………………………………………………………………………………19 24 ROTUNDA SCHEMATIC……………………………………………………………………………………………………………20 25 BOCA GRANDE SCHEMATIC……………………………………………………………………………………………………..21 26 WARRANTY CLAIMS……………………………………………………………………………………………………………….22 27 IMPORTANT WARRANTY INFORMATION……………………………………………………………………………………...23 2 Excessively high temperatures can be hazardous to your health. In order to get the most out of your spa. Position spa to provide drainage of the compartment for electrical components. Englewood. Your Gulf Coast spa is meant to be enjoyable. high or low blood pressure and pregnant women should consult a doctor before using the spa. The management and staff appreciate your patronage and takes pride in the tradition of quality spas that our company represents. For floor recessed spas. Any modifications to the procedures outlined in this manual may result in your warranty being void. diabetes. SAVE THESE INSTRUCTIONS! 3 . healthful and relaxing. 9) Lock the hard cover on any outdoor spas when not in use. THIS MANUAL AND ITS CONTENTS ARE SUBJECT TO CHANGE WITHOUT NOTICE. do not permit children to use this product unless they are closely supervised at all times. 5) Do not use the spa alone. we strongly suggest that you take time to read through this manual before you hook up and operate your spa. 3) Persons under the influence of medication. and safety procedures. Some basic safety rules do apply when using the spa. drugs or alcohol should not be allowed into the spa. and maintenance. Here is a small list of things to remember: 1) Always check the temperature of the spa before entering. Rotunda & Boca Grande) IMPORTANT SAFETY INSTRUCTIONS When installing your spa and using this equipment. ensuring an enjoyable experience right from the start. 6) The GFCI breaker should be tested monthly to ensure it operates properly. feel free to call your authorized Dealer. This will acquaint you with the operating features. Please take the time to read this manual to avoid any unnecessary problems with your brand new spa and equipment. WE WILL NOT BE LIABLE FOR LOSS. INJURY OR DAMAGES CAUSED BY IMPROPER INSTALLATION OR USE OF SPA (IMPROPER OR OTHERWISE). This Manual Covers the COOL NIGHTS SERIES (Sarasota. 4) Do not allow children to use the spa without supervision of an adult. hook up procedures. Gulf Coast Manufactures has tried to anticipate all of your needs and desires: however. always follow basic safety precautions including the following: READ AND FOLLOW ALL INSTRUCTIONS! DANGER: TO REDUCE THE RISK OF INJURY. install to permit access for servicing from above and below floor. 2) Persons suffering from heart disease. 8) Keep all breakables away from the spa area. WARNING! This manual was written to ensure the proper use and installation of any Cool Nights Series spa. if you need any additional information.INTRODUCTION Your Choice of a Gulf Coast spa indicates that you are devoted to excellence. 7) Any electrical devices near the spa must be GFCI protected and out of reach from inside the spa. Cape Haze. ALTHOUGH GULFCOAST MANUFACTURER HAS PREPARED THIS MANUAL AS ACCURATE AND PRECISE AS POSSIBLE. 5m) of the unit. As an alternative. metal enclosures of electrical equipment. and people under the influence of alcohol. if that item is located within 5 feet (1. ensure that children cannot use spa unless they are supervised at all times.4mm2) solid copper conductor between unit and any metal equipment. Should the need arise to replace the suction fittings or the pump/pumps. metal water pipe. DANGER – RISK OF ACCIDENTAL DROWNING: Extreme Caution must be exercised at all times. Occasional spa users may not be aware of some of the dangers hot water poses to pregnant women. To avoid accidents. POUR EVITER LE SOIN D'EXERCICE DE BLESSURE EN ENTRANT OU SORTIR LE SPA OU LE BAQUET CHAUD. 8 AWG (8. please contact your spa dealer or manufacturer.Maximum Flow rate for current used suctions). be sure that the flow rates are compatible (100 GPM . If you did not receive a warning sign or your sign has become damaged. This sign must be posted in a prominent place in close proximity to the spa installation site immediately upon completion of spa installation. or conduit. Cover spa and use safety locks to prevent accidents.5m) of metal surfaces if each metal surface 4 . DANGER – TO REDUCE THE RISK OF INJURY: The suction fittings in the spa are sized to match the specific water flow created by the pump/pumps. DANGER – RISK OF ELECTRICAL SHOCK: Install at least 6 feet (91. DANGER – A wire connector is provided on this unit to connect a minimum No. to prevent unauthorized access by children. WARNING SIGN – It is extremely important that this sign be permanently placed in clear view of any persons using the spa. EXERCISE CARE WHEN ENTERING OR EXITING THE SPA OR HOT TUB.5m) from all metal surfaces. WARNING SIGN MUST BE POSTED The (red) WARNING sign above is packed with your new Gulf Coast spa. small children. a spa may be installed within 5 feet (1.TO AVOID INJURY. lethargy. Fetal damage in pregnant women. Position spa to provide proper drainage of the compartment for electrical components. The use of alcohol. telephone. INSTALLATION Proper planning is an important consideration when installing your new spa. Planning ahead. The symptoms of hyperthermia include drowsiness.5m) of the spa. or medication before or during spa use may lead to unconsciousness with the possibility of drowning. Do not permit any electrical appliance. the user should measure the water temperature with an accurate thermometer. radio or television within 5 feet (1. The tolerances of water temperature-regulating devices vary. 8 AWG (8. drugs. fences etc. 1) Check out the local building codes with respects to gates. Consideration should be taken for water splash out. DO NOT set spa on blocks as structural damage may occur to spa. Failure to recognize the need to exit spa. should consult a physician before using a spa. The water in a spa should never exceed 40 degrees C (104 degrees F). 2) Be sure the spa will have proper access to water. blood pressure and circulation. drainage and electricity. A description of the causes. Since excessive water temperatures have a high potential for causing fetal damage during early pregnancy. and an increase in the internal temperature of the body. Failure to perceive heat. Persons suffering from obesity. unless factory installed. symptoms. and Unconsciousness and danger of drowning. Persons using medication should consult a physician before using a spa because some medications induce drowsiness while others may affect heart rate. will make the process of installation easier. circuit breaker. Site selection is a critical step and should be given some serious thought. pregnant or potentially pregnant women should limit water temperatures to 38 degrees C (100 degrees F). AVERTISSEMENT: DES TEMPERATURES DE L'EAU SUPERIEURES A 38C PEUVANT PRESENTER UN DANGER POUR LA SANTE.6 degrees F (37 degrees C). WATER TEMPERATURE IN EXCESS OF 38 DEGREES C MAY BE INJURIOUS TO YOUR HEALTH. before the delivery of your spa. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes. Water temperatures between 38 degrees C (100 degrees F) and 40 degrees C (104 degrees F) are considered safe for a healthy adult. WARNING – To reduce the risk of injury. Physical inability to exit spa. medical history or heart disease. Unawareness of impending hazard. DO NOT use a wall switch.is permanently connected by a minimum No. install to permit access for servicing from above or below floor. Water can ruin wood floors and some finishes. or diabetes. low/high blood pressure. Before entering a spa. 5 . DO NOT block access door. L'AVERTISSEMENT: LA TEMPERATURE D'EAU DEPASSANT 38C MAI EST NUISIBLE A VOTRE SANTE. or plugging and unplugging the spa as a means of turning on or off your spa for normal everyday use.4mm2) solid copper conductor to the wire connector on the terminal box that is proved for this purpose. Set the spa on a firm level (flat) surface. fuse. circulatory system problems. and effects of hyperthermia are as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98. HYPERTHERMIA – Prolonged immersion in hot water may induce hypothermia. For floor recessed spas. The following information is provided to assist you in site preparations. The effects of hyperthermia include. ground fault circuit interrupter. such as a light. The following specifications must be followed in order to ensure proper performance and safety. Make the access door in a logical place (i.e. CANADA/EUROPE: CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER. ALL SPAS MUST BE PROTECTED WITH AN OVER CURRENT PROTECTIVE DEVICE WITH BUILT-IN GROUND FAULT CIRCUIT INTERRUPTER (GFCI) IN THE SERVICE PANEL. the best answer is a 4-inch thick cement pad. In most cases. easy access must be provided beneath the spa. Please allow 36 inches. near controls and equipment). ITEMS Voltage Cape Haze-Single Pump 5.5 KW Heater 120 VAC 5.5 KW Heater Single Pump With Blower 230 VAC Cape Haze-Double Pump Englewood. However. FAILURE TO DO SO WILL CAUSE EQUIPMENT DAMAGE AND WILL NOT BE COVERED UNDER WARRANTY. Consult your authorized dealer for more details. 5) Check the load carry capabilities of the floor. 4) Be sure your spa will fit into the space you have chosen.5 KW Heater 230 VAC SPECIFICATIONS: Breaker Size:(amp/GFI) Wire Size (Gauge) 50 Amp Dedicated 6/3 With Ground 60 Amp Dedicated 6/3 With Ground 20 Amp Dedicated 50 Amp Dedicated 12/3 Standard Size 8/3 Standard Size ALL SPAS WITH DUAL 5. In most cases. Rotunda. there are many ways to support your spa. and insure there is proper access into the area of the spa for repairs if necessary. This will ensure proper serviceability to the plumbing and equipment. 6) Protect pump and all equipment from the weather. CAUTION! Failure to abide by specifications listed may result in damage to the equipment and may void the warranty. ATTENTION: CONNECTER UNIQUEMENT A UN CIRCUIT PROTEGE PAR UN DISJONCTEUR DIFFERENTIEL DE CLASS A. 6 . Most homes meet the requirement of 125 pounds per square foot. ELECTRICAL SPECIFICATIONS IMPORTANT! Qualified and licensed electricians must perform all electrical hookups. In many cases the equipment already is installed and needs no further protection. 5) Ventilation may be needed because of the humidity from the spa. IMPORTANT! When building a skirt or sinking a spa into a deck or ground. This is a minimum figure only! Consider your design carefully.0 HP PUMPS MUST BE WIRED WITH A 60 AMP BREAKER. a Spa Hard Cover is sufficient. Please consult your spa sales representative before constructing a base.3) Check with your dealer on how to support the weight. The more access the better. Boca Dual Pumps 230 VAC Sarasota-Single Pump 1. Spa Model. ALL SUPPLY CIRCUITS MUST BE DISCONNECTED. WARNING: DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING. AVERTISSEMENT: DISCONNECTER DU CIRCUIT D'ALIMENTATION ELECTRIQUE AVENT L'ENTRETIEN. Parts incorporating electrical components. must be located or fixed so that they cannot fall into the bath. 230vac/50Hz. 2x16A Single Phase. USE THE COPPER CONDUCTORS ONLY. except remote control devices. Earthed appliances must be permanently connected to fixed wiring. 7 . Gulf Coast Spa Manufacturers Parts containing live parts supplied with safety extra low voltage not exceeding 12v must be inaccessible to a person in the bath. EN60335-1 and EN60335-2-60. BONDING LUGS. EMPLOYER UNIQUEMENT DES CONDUTEURS DE CUIVRE.CSA Enclosure 3 – CAUTION: TEST THE GROUND FAULT INTERRUPTER BEFORE EACH USE OF THE SPA. Appliances should be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30ma. IPX5. TOUJOURS VERIFIER L'EFFICACITE DU DISJONCTEUR DIFFERENTIEL AVANT D'UTILISER LE BAIN. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. COSSES DEMISE A LA MASSE. BEFORE OBTAINING ACCESS TO TERMINALS. Power Source IN Ground (GREEN) INPUT To Spa Ground (Green) To Spa NOTE THIS: The white Neutral wire from the back of the GFCI MUST be connected to an incoming Line Neutral. The internal mechanism of the GFCI requires this neutral connection. including ampere sizing and selection of conductor size and type. and all federal. must be accomplished by a qualified electrician in accordance with the National Electrical Code. or The Canadian Electrical Code. state and local codes and regulations in effect at the time of installation. The GFCI will not work without it. 8 .IMPORTANT 6 Gauge Wire MUST Be Used! Breaker Box 60 AMP GFCI Load 120 Volts (RED) To Spa Load Neutral (WHITE) To Spa Load (RED) INPUT 60 Amps Load 120 Volts (BLACK) To Spa Load (BLACK) INPUT Pig Tail (WHITE) From GFCI Breaker Going To Neutral Bar In Box Load Neutral Bar Load Neutral (WHITE) INPUT Ground Bar Attached To Box (GREEN) INPUT & OUT IMPORTANT NOTE: Installation of this GFCI-Circuit Breaker. DO NOT turn pump on until the spa is filled to the required level. CAUTION! DO NOT use a wrench. CAUTION! Be sure drain bib is closed before the water is turned on. Clean out the spa and remove any foreign material. These are hand-tightened unions and over tightening may cause damage to unions and gaskets. These are usually located to the left of the pump and to the right of the equipment head. Running the pump dry may cause IMMEDIATE damage. which may not be covered under warranty. Be sure the Slide Valve T-Handles are pulled out completely. Fill spa with water (hard water is recommended) to approximately 4 inches from the top of the spa. All valves must be open from the spa to the spa pack. Slide Valve T-Handle Union Check and tighten unions at each end of the heater tube. Simply put a garden hose directly into the spa.STARTUP PROCEDURES IMPORTANT! Read these step-by-step startup procedures before starting your spa. which will not be covered under warranty! 9 . Gel Gloss Acrylic Polish or any type of soft paste wax is recommended for polishing the surface of your spa. Failure to follow any of these steps listed may result in damage to the equipment and may void the warranty. NOTE: Running the spa pump dry (without water running through it) could cause IMMEDIATE damage! Be sure the following conditions exist: The spa has been installed properly in accordance with the instructions in this manual. CHEMICAL-FREE AQUACLARA WATER MANAGEMENT SYSTEM* Chemical-Free … Hypoallergenic … Easy-To-Use Gulf Coast Spas now offers a chemical-free water purification system for your spa. 10 . the AquaClara Water Management System removes harmful metals and makes your water feel softer without adversely affecting valuable minerals. Go to www. the Vortec Filtration Method. AquaClara™ Does this For You! There is no maintenance required for your spa shell. check to make sure the valves are open at the pump. viruses and bacteria in the water The Vortec Filtration Method then filters solid particulates out of the water Water then passes through the copper and zinc ions on the AquaClara Disc. open the air valve (AVC) to the jets and you should see a great increase in jet pressure. If the water is running smoothly through the lines. How it Works Microban® is an antimicrobial agent impregnated into the acrylic for the life of the spa that repels bacteria off the spa shell The Ozonator hyperoxygenates the water to kill algae. 1. Start the pump and watch for some water to come out of the jets. removing harmful elements such as lead and inorganics while creating a bacteriostatic environment in the filter *AquaClara Water Management System must be used in conjunction with a sanitizer. Place TWO to THREE AquaClara Tablets UNDER the AquaClara Disc weekly. 2. the Ozonator. simply keep it clean. You NEVER have to worry about: • • • Testing or balancing your purifier level Testing or balancing your pH level Testing or balancing your total alkalinity level • • • • • Testing or balancing your calcium or hardness level Adding clarifier Adding scale remover Adding stain or scum remover Adding foam remover Plus. 3. You will save hundreds of dollars annually with this easy-to-use system.GulfCoastSpas. please call the 24-hour Gulf Coast Spa Manufacturers service line at (727) 573-9888. CAUTION! The water from your hot water tank should not be used to fill the spa.Once the spa is filled to the proper level. SPECIAL NOTE: If you are unsure of any of the above startup procedures. 4. All without using chemicals! With the combination of the copper and zinc media in our exclusive AquaClara Water Management System – our patented AquaClara Disc.com/store for details. attach a garden hose to the drain bib and open the valve. Do not exceed “02” filtration cycle while using the AquaClara Water Management System. When you are ready to drain the water. and Microban® – the need for excessive chemicals is eliminated. See the console diagram for help setting the temperature. The pumping unit will heat the water as it pumps. Plugging in the Sarasota Plug the power cord directly into a dedicated. press the pump button on the console to turn on the Sarasota. The water will heat at approximately 3. . grounded circuit capable of carrying 20 or more amps. programmable heating (94° to 104°) and filtration system. First. Second. Starting the Sarasota Once you have tested the GFCI. Make sure the cut-off valves to the pump are open and fill the spa with water. press the GFCI “reset” button. Set the air control on the console to the lowest setting (see console diagram). Immediately replace the power cord is it becomes damaged. The power cord is equipped with a Ground Fault Circuit Interrupter located at the end of the power cord. the GFCI is damaged. The Sarasota should turn off. the spa will turn on automatically. Plug in the power cord and turn the spa on. The guidelines below explain how to properly use the Sarasota. The Sarasota should resume normal operation. If the Sarasota continues to run after the “test” button is pressed. The 15 hydrotherapy jets can be regulated to provide a relaxing massage to sooth away stress and the air control valve can be turned to adjust the strength of the water massage. Do not use the Sarasota until a qualified electrician repairs the GFCI. Follow these guidelines to maintain the spa for your long-term vacation at home. No other appliances should be on the same circuit. The Sarasota holds approximately 222 gallons of water and offers an automatic. Third. Place the cover tightly on the Sarasota. you should verify the water flow from the pumping unit. If you are using the spa indoors and the room temperature is maintained at 70°F. 11 .SARASOTA INSTRUCTIONS The Sarasota is designed to seat two adults. press the GFCI “test” button. Note: The first time the power cord is plugged in. it will take approximately eight hours for the water to reach the set temperature. You always should test the GFCI before using the Sarasota.4° per hour with the cover on. The indicator will illuminate while the pump is running in high speed and flash while running in low speed. the system will call for heat. the Temperature Set Indicator will be lit. After five seconds. the indicator above the button will be lit. Press the down arrow key to decrease the temperature. The light automatically will turn off after two hours. oversized knob determines the amount of air that is released in the spa jet system when the pump is on. All functions (except the alarms) will be disabled while the freeze protection is active. poor 12 . Turn the control to the left and more air will flow through the jets providing maximum hydrotherapy. Light Key: This button turns the light on and off. During this time. the display will return to the current temperature reading. Turn the control to the right for less air in the jets and softer hydrotherapy. a filtration cycle has begun and you will not be able to turn off the pump. the pump and heater will turn on for two minutes or until the temperature reaches 50º F. FrE will be displayed throughout this cycle.Sarasota Console Diagram Using the Sarasota Console Pump Key: Press this key once to turn the pump on low speed. If the filter indicator is lit. Freeze Protection: If the water temperature drops below 49º F. Temperature Keys: Press the up arrow key to increase the temperature. the system will display an HL message and the heater will turn off. If the water temperature does not seem to be elevated. When the temperature drops to 1º F below the set temperature. informing you that this is the desired temperature not the actual temperature. Press this key a third time to turn off the pump. Press this key a second time to turn the pump on high speed. press any key on the console to resume normal operation. Unless manually turned off. After the water has cooled. all outputs will be shut off. If the water temperature exceeds 122º F at the Hi-Limit sensor. Air Control: This easy-to-use. The Heat On Indicator will be lit while the heater is on and flash when there is a call for heat and the heater has not yet been activated. The temperature can be adjusted in 1º increments between 41º F and 104º F (5º C and 40º C). High Temperature Protection: If the water temperature exceeds 115º F at the Hi-Limit sensor. the pump automatically will shut off after 20 minutes. The new setting will remain on the screen for five seconds as a confirmation. When the light is on. Note: If no key is pressed within five seconds during programming.GulfCoastSpas.com or call Gulf Coast Spas’ 24/7 service hotline at (727) 573-9888. Programming Filter Cycle: You may choose to filter the spa one.water flow or electrical line interference (thunder storms. voltage surges. Press the up or down arrow keys to increase or decrease the frequency of the filtration cycles. The system will revert back to display the water temperature within five seconds. HL – Hi-limit protection Three flashing dots mean the system has detected a problem with the pressure switch or the high limit probe. Press and release the light key and up arrow key at the same time.) may have caused the HL message. Simply reset and monitor the system. the system will revert back to the monitoring mode. Press and release the pump key and up arrow key at the same time. The system should reset itself when the water cools down to 109º F. 12 or 24 hours. Sarasota System Messages FLC – Flow-related FLO – Flow-related Default System Operation: When power is applied or there is a temporary loss of power. press and release the pump key and up arrow key at the same time. PrH – Hi-limit sensor Prr – Temperature sensor FrE – Freeze protection engaged For troubleshooting assistance visit www. Gulf Coast recommends setting the filtration cycles opposite sleeping hours. press and release the light key and up arrow key at the same time. To save the new setting. The current setting will be displayed. If the pump and/or light were turned on during programming. To save the new setting. the system will initiate its default programming. etc. Check and open water valves. The filtration cycle will be active for one hour and will repeat every 24 hours. Programming Filter Cycle Duration: You may choose to filter the spa 60. 13 . Flashing water temperature on the display means the water temperature has reached 112º F. The temperature will be maintained at 95º F. Remove spa cover and allow water to cool down. Press the up or down arrow keys to increase or decrease the duration of the filtration cycles. 120 or 180 minutes per cycle as required to keep the water clean and sanitary. The cycles will repeat every eight. Freeze protection will be active. The current setting will be displayed. Shut power off and power up the spa again to reset the system. Clean filter or add water if necessary. The filter cycle will begin 24 hours after the system has been powered up. two or three times a day as required to keep the water clean and sanitary. turn them off. 14 . NOT the current water temperature! Water temperature can be adjusted by 1° increments from 59° to 104° F. Use Up or Down arrow key to regulate water temperature.5° C). Press a second time to turn light off. The “Pump 1” indicator lights up when Pump 1 is on. A built-in timer automatically turns Light off after 2 hours. Setting Water Temperature: Starting Pump 2: Press Pump 2 key to turn Pump 2 on.5° C) lower than the Set Point. unless manually deactivated first. at low speed. The “Pump 2” indicator lights up when Pump 2 is on. The “Blower” indicator lights up when Pump 1 is on. A built-in timer automatically turns pump off after 20 minutes. Press a second time to turn Blower off. unless it has been manually deactivated. unless it has been manually deactivated. A third time turns pump 1 off. The temperature setting will be displayed for 5 seconds to confirm your new selection. 15 . Pressing a second time turns Pump 2 off. A built-in timer automatically turns pump off after 20 minutes. The “Set Point” symbol indicates the desired temperature. Press a second time to turn Pump 1 to high speed. The “Heater” indicator lights up when the heater is on. A built-in timer automatically turns pump off after 20 minutes.ONE-TOUCH CONTROLS Top Side Control Functions The Quick Reference Card provides a quick overview of your spa’s main functions and the operations accessible with your digital control Starting Pump 1: Press Pump 1 key to turn Pump 1 on at low speed. The “Light” indicator lights up when Light is on. Automatic water heater start: When water temperature is 1° F (0. Turning on Light: Press Light key to turn Light on. the heater will automatically turn on until water temperature reaches Set Point plus 1° F (0. Starting the Blower: Press Blower key to turn Blower on. unless it has been manually deactivated. PROGRAMMING FILTER CYCLES The system automatically performs two cycles per day. Pressure Switch Heating Housing and Heater Element Inside Tube 16 . exceeds Set Point by more than 2° F (1° C). The “Filter Cycle” indicator lights up when a filter cycle is on. The cycle will be suspended for 40 minutes beyond the last manual activation of any accessory.Ozonator is turned on. Note: After a power failure. The filter cycle will be suspended if the user enters the spa and activates a pump or blower manually. filtering will resume for the remainder of the programmed cycle. . During a filter cycle: . To set the filter cycle duration: Press and hold Light key for 5 sec. press Light key again to confirm. If temperature cools down before the scheduled end of the cycle.Pump 2 and Blower run at high speed for one minute. . The filter indicator will flash on the display while the filter cycle is suspended. The display will show xx. An irregularly flashing “Filter Cycle” indicator means that the system has stopped filtering after 3 hours because water temp. at 12-hour intervals. This is to prevent unnecessary operation of the ozonator. with “xx” representing the number of hours Pump 1 will be running at low speed. the first filter cycle will start 12 hours after power has been restored. Use Up or Down arrow key to change setting. the filter cycle duration will return to its default value (6 hours). When the desired setting is displayed. GULF COAST MANUFACTURERS EQUIPMENT PACK Color Coded Spa Equipment Hook ups.Pump 1 runs at low speed for a programmed number of hours. In this case. 00 = no filtration 12 = continuous filtration. A thin coat of linseed or cotton oil treatment applied twice a year will help maintain the cabinet’s luster.209 liters) DRY: 730 lbs (331 kg) FULL: 3. What is the insulation made of? Gulf Coast uses a five-step Thermazone™ process to fully insulate all of its hot tubs.018 kg) 222 gallons (842 liters) DRY: 590 lbs (267 kg) FULL: 3. an outer layer of insulation is added.790 lbs (2. How do I use aromatherapy? Remove scented bead cartridge from plastic cover. THIS WILL CREATE BACKFLOW AND POSSIBLE DAMAGE TO YOUR SPA! How do I maintain my cabinet? California Redwood is virtually maintenance free. an inner layer of insulation is wrapped around the entire cabinet.425 kg) 319 gallons (1. If you encounter a matter that can’t be easily resolved over the phone. CAUTION: DO NOT TURN OFF TOO MANY JETS AT THE SAME TIME.918 kg) 430 gallons (1. Gulf Coast customers are guaranteed to receive service response priority. Call our service department at (727) 573-9888. a bottom layer of insulation is added on the floor. Fifth.142 lbs (1. clean with a citrus-based product. How do I adjust my jet? Simply turn the jets counterclockwise to open and clockwise to close. Second. a local technician can be dispatched to your home. Fourth. Twist off aromatherapy injector valve cap on top of spa (refer to No.FREQUENTLY ASKED QUESTIONS Who do I call for warranty information or service? Trained representatives from Gulf Coast Spas are available 24 hours a day. Replace cap.229 lbs (1.892 liters) DRY: 790 lbs (358 kg) FULL: 4. 20 on your spa schematic sheet). Are the jets removable? Interchangeable? Replaceable? Most jets are made removable for easy cleaning and customized hydrotherapy. Insert scented bead cartridge.172 kg) 500 gallons (1. First. We recommend you remove them every 3 months.246 lbs (1. Who are the service companies in my area? Gulf Coast Spas contracts with several service companies in your area to ensure the best possible response time. What happens when my warranty is expired? Gulf Coast Spas will continue to service your spa after your warranty has expired via its 24/7 service hotline – (727) 573-9888.630 liters) 17 . rinse thoroughly and replace. Third. a 5-inch thick tapered cover is included. the bottom of each tub is blanketed with a thick layer of solid-cell. as damage can occur.637 kg) 360 gallons (1. Be careful not to overturn the jets. What does my spa weigh and how much water does it hold? SARASOTA CAPE HAZE ENGLEWOOD ROTUNDA BOCA GRANDE DRY: 470 lbs (213 kg) FULL: 2. Call (727) 573-9888. seven days a week to meet all of your needs.365 liters) DRY: 790 lbs (358 kg) FULL: 4. high-density insulating foam.610 lbs (1. Reduce filtration time to 01. CAUSE 3: Fuse is blown. CAUSE 2: Thermostat is set too high. CAUSE 2: System is air locked. Reset temperature to lower setting. Problems may arise that may or.com) Check and clean filter. If a problem does arise.GulfCoastSpas. Check and clean filter. Purge/bleed system at heater tube. Add cold water if necessary. Check and reset breaker. Turn off light by pressing light key. 7 days a week at (727) 573-9888 or refer to the interactive SpaTech™ located at www.GulfCoastSpas. Check and open all valves.) 18 . PROGRAMMED FILTRATION CYCLE HAS STOPPED PREMATURELY CAUSE: Light was turned on. POOR JET PRESSURE CAUSE 1: Filter is dirty. or may not require service. check the following troubleshooting guide for a solution. CAUSE 2: Thermostat is too low. WATER WILL NOT HEAT CAUSE 1: Filter is dirty. If the problem cannot be solved in this manner. (If the weather is extremely hot. remove the spa cover. Check and replace fuse. WATER IS TOO HOT/OVER TEMPERATURE CAUSE 1: System is filtering too long. SOLUTION Reset desired temperature and filtration cycle.TROUBLESHOOTING GUIDE Gulf Coast Spa Manufacturers always has endeavored to represent spas that are second to none in terms of quality. CAUSE 3: Jets are closed. NOTHING WORKS CAUSE: Breaker has tripped. Open jets by rotating counterclockwise. check all electrical connections to ensure none are loose. Check and reset to desired temperature. please call our service hotline 24 hours a day. Running the blower may help cool the water.com. resume normal operations. PROBLEM 95 FLASHING ON TOP SIDE CONTROL CAUSE: Power to spa has been disrupted. (see www. Filtration will resume and complete the programmed cycle 40 minutes beyond the last manual activation/de-activation. If the problem persists. CAUSE 4: Slide shut-off valves are closed partially or completely. Upon each change of water it is good practice to wipe down the spa. It is recommended to treat the skirt periodically with a water . 19 .resistant stain or a good grade linseed oil. the water in your spa should be changed every 1-3 months. Remove cap from drain bib. WATER – Depending on usage. CABINET SKIRTING – Maintenance on your skirt is minimal. 6. 5) Do not lift the cover by the safety straps. 2. 7. they are made to secure the tub to the cabinet and may tear. simply inspect the spa pack’s self-monitoring lights. This will ensure that the water is being filtered properly. Pull knob firmly for full flow. When changing the filter. This will enable you to quickly exchange the dirty filter with the clean one and immediately start your spa again. This will help make the finish last longer and look better. A special section of this manual will cover the AquaClara Water Management System. wearing of the vinyl could easily develop into a tear. or vinyl cleaner. SPA COVER – The 5-inch thick tapered cover on your spa is made from a weatherproof marine vinyl. Turn knob counterclockwise (open) until it stops. and there is no restriction in the filter due to dirt and grease. FILTER – The filter in your spa should be cleaned every week. 2) The insulating foam in your cover is not designed to hold the weight of a person or an animal. 5. this can increase its life by allowing better ventilation. It is recommended to have a second filter. which can be swapped between cleanings. 4. Your cover will last much longer if you heed the following suggestions: 1) Don’t drag the cover on the ground. 4) Dura Shine applied to the cover & stitching once yearly will keep your cover looking better longer. the following maintenance procedures must be followed periodically. To Drain the Water: 1. IMPORTANT! Cracked foam in the cover is not covered under warranty! 3) Occasionally wipe the cover. Push knob back in place. This will open the pores of the acrylic and remove dirt and scum while putting a protective coating on the acrylic keeping dirt and scum from permanently staining the spa acrylic. 3. Wipe off dust from the spa pack. SPA CONTROL PACK – The spa support pack requires very little maintenance over its life span. inside and out with soap and water. Drain. Turn knob clockwise (closed) until it stops. IMPORTANT! Cleaning the filter can be done easily using pressure from a hose to remove debris from the paper element.MAINTENANCE and CARE IMPORTANT! The warranty on your spa and equipment is dependent on proper use of the AquaClara Water Management System™. Replace cap on drain bib. In addition. remove the spa control pack from the spa (see page 12) and bring inside for protection from freezing. follow the above shutdown procedures in addition to the following: Drain the spa until absolutely no water remains.SHUTDOWN PROCEDURES Your spa must be emptied approximately every 1-3 months to ensure the spa water is clean and safe. Due to possible cold weather. A long-term shutdown may be due to an extended vacation or a mechanical failure. Connect a hose to the garden hose bib on the spa and open the garden hose bib valve. Unhook the suction and return lines by loosening both unions on the heater tube and drain lines as much as possible. Turn off the pump. Use Wet Dry Vacuum if necessary to either blow all lines clear or to suck all lines clear. your spa pack fails and service is not immediately available to you. Pump. Drain the spa until the waterline is just above the bottom suction of your spa in the foot well. If possible. a number of special accessories may be neccessary to facilitate a long-term shutdown. If necessary. Vacuum out Jets. If the spa is to be out of service for a long time. Follow these step-by-step procedures whenever you need to empty your spa: The spa must be turned off. call the Gulf Coast 24-hour technical support hotline at (727) 573-9888. it may be necessary to squirt RV antifreeze into each jet to prevent any freezing. LONG-TERM SHUTDOWN: If you wish to shut down your spa for an extended period of time. 20 . CAUTION! DO NOT let the pump run dry. certain requirements must be met. WARNING! If these steps are not taken during cold weather when the spa is shut down. IMMEDIATE DAMAGE may result which could void the warranty. These include: Sump Pump Wet Dry Vacuum Small electric heater (MUST be used in cold weather) RV recreational antifreeze (MUST be used in cold weather) If in winter. Simply turn off the heater switch or turn down the thermostat to the lowest setting. Bail out the remaining water (using a Wet Dry Vacuum). serious damage to the lines and spa may result! Freezing of the spa and/or equipment is not covered under warranty. Place a small electric heater under the skirting of the spa. and Filter Canister with a Wet Dry Vacuum. Remove filter from canister. Heater. MINI JET 212-0300. CORD BLOWER OZONE GENERATOR OWNER'S MANUAL 6087. 7384 7068 1 0 0 1 12/3 CORD 115V/1HP/60HZ 115V/60HZ GULF COAST . 212-8177S 0 9 ADJ.6071.4A. FILTER 212-0300. 212-1507S 8 120/240/16/40/60 20/50 2 AIR INJECTOR JET 7377 0 3 NON ADJ.1. 711-4400. JET 212-0400. DIR.5/0. 218-4010. 218-6680. 212-2067S 0 12 AIR CONTROL 660-3587(660-4407) 1 13 HI-FLO SUCTION 10-6764(GREY) 1 14 WATERFALL 6" 675-4007 0 3111 1 15 16 LIGHT ASSEMBLY DYNO-FLO SKIM FILTER W. 212-7937S 210-1627 212-0400. 218-5150. P1 ASSEMBLY (MOTOR. 212-1497S 0 4 MINI ROTO JET 6 ADJ. 718-6960. UNION) N/A P2 ASSEMBLY (MOTOR. 711-6900. 218-4010. 35 SQ. 212-8057S 6 8 POLY STORM TWIN ROT O JET (LARGE FACE) 212-0400. 210-6817S 0 11 POWER STORM JET 212-2010G.018 REF.4/4. UNION) N/A N/A N/A N/A 20A GFCI W. P. CLUSTER JET 212-1550G. 711-4400. FT FILTER CARTRIDGE 817-3501 0 19 PILLOW 12" 3012 0 20 AROMATHERAPY INJECTOR 23041001 0 21 AROMA GARDENIA 23040500 0 22 ACRYLIC 78" X 90" GR 7021078090 1 23 SPA FLOOR DRAIN WITH VALVE 7381. 817-3501 1 1 17 FILTER LID 3003 18 35 SQ. W ETEND. 6105 7550 1 1 27 WALL FITTING 212-1827 1 28 WATERFALL VALVE 600-4367 0 IF SUPPLY SEPARATELY CS6100-VDS 76" X70" X 6RC H21 MODEL: 5000/SARASOTA EQUIPMENT ASSEMBLY & MANUAL N/A N/A ELECTRICAL CONTROL.C. 7379 1 24 THERMOWELL 7380 1 25 26 SPA SIDE CONTROL SPA COVER (BROWN) 6103. CLUSTER STORM JET 212-1550G. W ETEND. FT. 718-6960.INTERIOR & PLUMBING PARTS SPA MODEL SPA DIMENSION NUMBER SEATS WATER JETS AIR JETS WATER CAPACITY (USG) DRY WEIGHT (LBS/KG) FILLED WEIGHT (LBS/KG) ELECTRICAL RATING (VAC/AMP/HZ) GFCI (AMP) 5000/SARASOTA 73" X 79" X 30" 3 ADULTS 15 0 222 470/213 2. FACE PLAT E G. 212-7927S 10 JUMBO STORM JET 711-0090. 212-8017S 0 7 POLY STORM DIR. CORD. 400-4060(2PER PUMP) 1 1 120/240V/16/40A/60HZ 115V/16. CORD. 218-4010. 310-1143HS. EURO JET 5 POLY STORM ROTO JET (LARGE FACE) 6 POLY STORM ROTO JET 212-0400. 218-5150. # ITEM DESCRIPTION GULF COAST PART # QTY 1 ADJ.25HP/60HZ 0 2475 6080 7382. 212-8147S NOTES 0 6 0 0 510-6547HS. 711-6900. 711-4400. 711-4400. 218-4010. P.246/1. 6089(CS6100-VDS) 5040. 711-6900. FT FILTER NOTES 17 FILTER LID 3003 1 18 35 SQ. 711-4400. OVERLAY G.C. 212-7937S POLY STORM TWIN ROT O JET (LARGE FACE) 0 0 9 ADJ. 7384 N/A OWNER'S MANUAL 7068 1 1 0 0 1 1 1 240V/48A/60HZ (CS6230-VDS) 230V/12/4. 212-7927S 2 7 240/40/60 50 8 212-0300. 6084 7552 1 1 27 WALL FITTING 212-1827 1 28 WATERFALL VALVE 600-4367 1 29 SUPER HI-FLO SUCTION 640-3607 1 IF SUPPLY SEPARATELY CS6230-VDS 80" X 80" X 6RC H22 MODEL: 7000/CAPE HAZE EQUIPMENT ASSEMBLY & MANUAL N/A N/A N/A N/A ELECTRICAL CONTROL. 718-6960. FACE PLAT E G. 212-8147S 0 6 POLY STORM ROTO JET 212-0400. UNION) 20A GFCI W. 817-3501 1 16 DYNO-FLO SKIM FILTER W. 218-5150. 6101 7136/6071/310-1753HS/4005650(2PER PUMP) 7135/6076/310-1753HS/4005650(2PER PUMP) 2475 N/A BLOWER 6080 N/A OZONE GENERATOR 7382. 35 SQ. P. 711-4400. 218-4010. 212-1497S 4 MINI ROTO JET 5 POLY STORM ROTO JET (LARGE FACE) 212-0400.INTERIOR & PLUMBING PARTS SPA MODEL SPA DIMENSION NUMBER SEATS WATER JETS AIR JETS WATER CAPACITY (USG) DRY WEIGHT (LBS/KG) FILLED WEIGHT (LBS/KG) ELECTRICAL RATING (VAC/AMP/HZ) GFCI (AMP) 7000/CAPE HAZE 81" X 81" X 35" 6 ADULTS 21 10 319 590/267 3. FT FILTER CARTRIDGE 817-3501 0 19 PILLOW 12" 3012 3 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 90" X 90" GR 7021090090 1 23 SPA FLOOR DRAIN WITH VALVE 7381. 210-6817S 0 11 WHIRLPOOL JET 212-2010G. 218-4010. CORD 6099. CLUSTER JET 212-1550G. MINI JET 10 JUMBO STORM JET 711-0090. 218-4010. 7379 1 24 THERMOWELL 7380 1 25 26 SPA SIDE CONTROL. P1 ASSEMBLY (MOTOR. DIR. 212-8017S 7 POLY STORM DIR. SPA COVER (BROWN) 6070. 711-6900. 218-4010. 212-2067S 0 12 AIR CONTROL 660-3587(660-4407) 2 13 HI-FLO SUCTION 10-6764(GREY) 1 14 WATERFALL 6" 675-4007 1 15 LIGHT ASSEMBLY 3111 1 510-6547HS.425 REF. 212-8177S 0 212-0300. 718-6960. # ITEM DESCRIPTION GULF COAST PART # Q-TY 1 ADJ.142/1. 212-1507S 5 10 2 AIR INJECTOR JET 7377 3 NON ADJ. W ETEND.0/60 12/3 CORD 115V/1HP/60HZ 115V/60HZ GULF COAST . 218-6680. UNION) P2 ASSEMBLY (MOTOR. P. 711-4400. JET 212-0400.4A/60 230/12. W ETEND. 212-8057S 6 212-0400. CORD. CORD. 218-5150. CLUSTER STORM JET 212-1550G. 711-4400.C. 718-6960. JET (LARGE FACE) 212-0400.2. 218-4010. OVERLAY G. 218-5150.6. 218-6680. 212-7937S 5 5 POLY STORM ROTO JET (LARGE FACE) 212-0400. P.0(SEATS 4. 7379 1 24 THERMOWELL 7380 1 25 26 SPA SIDE CONTROL. SPA COVER (BROWN) 6070. JET 212-0400.4A(SEATS 1. UNION) 20A GFCI W. P. FACE PLATE P1 ASSEMBLY (MOTOR. 212-8057S 0 212-0400. 711-4400. 35 SQ. 218-4010. 7384 7068 1 1 1 0 1 1 1 240V/48A/60HZ (CS6230-VDS) 230V/12/4. DIR. W ETEND. CORD. 218-4010. 711-4400. 212-1507S 7 7377 12 2 AIR INJECTOR JET 3 POLY STORM DIR. FT FILTER CARTRIDGE 817-3501 0 19 PILLOW 12" 3012 3 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 90" X 90" GR 7021090090 1 23 SPA FLOOR DRAIN WITH VAL VE 7381. CORD BLOWER OZONE GENERATOR OWNER'S MANUAL 6099.SPA MODEL SPA DIMENSION NUMBER SEATS WATER JETS AIR JETS WATER CAPACITY (USG) DRY WEIGHT (LBS/KG) FILLED WEIGHT (LBS/KG) ELECTRICAL RATING (VAC/AMP/HZ) GFCI (AMP) 8000/ENGLEWOOD 86" X 86" X 35" 7 ADULTS 33 12 360 730/331 3. 212-8167S 3 4 MINI ROTO JET 212-0300. 817-3501 1 16 Seat 5 Seat 6 POLY STORM TWIN ROTO JET (LARGE FACE) DYNO-FLO SKIM FILTER W. 6101 7136/6071/310-1753HS/4005650(2PER PUMP) 7135/6076/310-1753HS/4005650(2PER PUMP) 2475 6080 7382. 718-6960.637 INTERIOR & PLUMBING PARTS 240/48/60 60 REF. 212-8147S 1 6 POLY STORM ROTO JET 212-0400.WF) 230/12. 711-6900. 218-4010.3. 212-8177S 12 212-0300. 212-8017S 0 POLY STORM DIR. # ITEM DESCRIPTION GULF COAST PART # Q-TY 1 ADJ. 212-7927S 4 7 8 9 ADJ. 711-4400. UNION) P2 ASSEMBLY (MOTOR. MINI JET 10 JUMBO STORM JET 711-0090.7) 12/3 CORD 115V/1HP/60HZ 115V/60HZ GULF COAST .610/1. 6084 7554 1 1 1 27 WALL FITTING 212-1827 28 WATERFALL VALVE 600-4367 1 29 SUPER HI-FLO SUCTION 640-3607 1 NOTES IF SUPPLY SEPARATELY CS6230-VDS 84" X 84" X 6RC H22 MODEL: 8000/ENGLEWOOD EQUIPMENT ASSEMBLY & MANUAL N/A N/A N/A N/A N/A N/A N/A ELECTRICAL CONTROL. W ETEND. 210-6817S 0 11 WHIRLPOOL JET 212-2010G.5. FT FILTER 17 FILTER LID 3003 1 18 35 SQ. CORD. 212-2067S 0 12 AIR CONTROL 660-3587(660-4407) 3 13 HI-FLO SUCTION 10-6764(GREY) 3 14 WATERFALL 6" 675-4007 1 15 LIGHT ASSEMBLY 3111 1 510-6547HS. 711-4400. 711-4400. CLUSTER STORM JET 212-1550G.C. 711-6900. 218-4010. CORD BLOWER OZONE GENERATOR OW NER'S MANUAL 6099. 210-6817S 1 11 WHIRLPOOL JET 212-2010G. 711-4400. UNION) P2 ASSEMBLY (MOTOR. 212-8057S 5 212-0400. 718-6960. 6084 1 CS6230-VDS 26 SPA COVER (BROWN) 7556 1 93" X 93" X 6RC H22 27 WALL FITTING 212-1827 1 28 WATERFALL VALVE 600-4367 1 29 SUPER HI-FLO SUCTION 640-3607 1 EQUIPMENT ASSEMBLY & MANUAL N/A N/A N/A N/A N/A N/A N/A 0 10 15 Seat 5 0 212-0300. 218-4010. 718-6960. OVERLAY G. DIR. 35 SQ. MINI JET JUMBO STORM JET 711-0090. 711-4400. FACE PLATE P1 ASSEMBLY (MOTOR.172 HZ) INTERIOR & PLUMBING PARTS 240/48/60 60 REF. P. JET 212-0400. 7384 7068 1 1 1 0 1 1 1 240V/48A/60HZ (CS6230-VDS) 230V/12/4. 212-7937S POLY STORM TWIN ROTO JET (LARGE FACE) NOTES IF SUPPLY SEPARATELY MODEL: 9000/ROTUNDA ELECTRICAL CONTROL. W ETEND. 212-1497S 4 MINI ROTO JET 5 POLY STORM ROTO JET (LARGE FACE) 212-0400.5.3. 711-4400. 711-4400. 212-1507S 5 10 2 AIR INJECTOR JET 7377 3 NON ADJ. 218-4010. 218-6680. CLUSTER STORM JET 212-1550G. UNION) 20A GFCI W. CLUSTER JET 212-1550G.WF) 230/12. # ITEM DESCRIPTION GULF COAST PART # Q-TY 1 ADJ. 218-5150. P. 212-7927S 4 7 8 9 ADJ. 711-6900. 6101 7136/6071/310-1753HS/4005650 (2PER PUMP) 7135/6076/310-1753HS/4005650 (2PER PUMP) 2475 6080 7382.C. 212-8017S 4 POLY STORM DIR.SPA MODEL SPA DIMENSION NUMBER SEATS WATER JETS AIR JETS WATER CAPACITY (USG) DRY WEIGHT (LBS/KG) FILLED WEIGHT (LBS/KG) ELECTRICAL RATING (VAC/AMP/ GFCI (AMP) 9000/ROTUNDA 95" X 95" X 40" 7 ADULTS 28 10 500 790/358 4. 711-6900. 7379 1 24 THERMOWELL 7380 1 25 SPA SIDE CONTROL. 817-3501 1 17 FILTER LID 3003 1 18 35 SQ. 218-4010. FILTER 3111 1 510-6547HS. CORD.7. 218-4010. 212-2067S 0 12 AIR CONTROL 660-3587(660-4407) 4 13 HI-FLO SUCTION 10-6764(GREY) 3 14 WATERFALL 6" 675-4007 1 16 LIGHT ASSEMBLY DYNO-FLO SKIM FILTER W. 212-8177S 6 212-0300. FT FILTER CARTRIDGE 817-3501 0 19 PILLOW 12" 3012 4 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 100" X 100" GR 7021100100 1 23 SPA FLOOR DRAIN WITH VAL VE 7381.0/60 (SEATS 4. 6070. 212-8147S 2 6 POLY STORM ROTO JET 212-0400.2. FT. 218-5150. W ETEND.790/2. CORD.4A (SEATS 1.6) 12/3 CORD 115V/1HP/60HZ 115V/60HZ GULF COAST . 711-6900.SPA MODEL SPA DIMENSION NUMBER SEATS WATER JETS AIR JETS WATER CAPACITY (USG) DRY WEIGHT (LBS/KG) FILLED WEIGHT (LBS/KG) ELECTRICAL RATING (VAC/AMP/HZ) GFCI (AMP) 10000/BOCA GRANDE 94" X 94" X 35" 6 ADULTS 43 14 430 790/358 4. 212-8177S 9 9 ADJ. W ETEND.6) 12/3 CORD 115V/1HP/60HZ 115V/60HZ GULF COAST . 711-4400. CORD.4. 218-4010. 6084 7558 1 1 27 WALL FITTING 212-1827 1 28 WATERFALL VALVE 600-4367 1 29 SUPER HI-FLO SUCTION 640-3607 1 NOTES IF SUPPLY SEPARATELY CS6230-VDS 92" X 92" X 6RC H22 MODEL: 10000/BOCA GRANDE N/A N/A N/A N/A N/A N/A N/A ELECTRICAL CONTROL. JET 212-0400.0(SEATS 1. FILTER 17 FILTER LID 3003 1 18 35 SQ.229/1. 218-4010. DIR. 212-8057S 0 8 POLY STORM TWIN ROT O JET (LARGE FACE) 212-0400. 711-4400. P1 ASSEMBLY (MOTOR. 212-1507S Q-TY 9 7377 14 2 AIR INJECTOR JET 3 POLY STORM DIR. 212-8017S 5 7 POLY STORM DIR.4A(SEATS 2. SPA COVER (BROWN) 6070. 817-3501 1 16 DYNO-FLO SKIM FILTER W. 218-4010. P. W ETEND. 35 SQ. 711-4400. 218-4010. 718-6960. 6101 7136/6071/310-1753HS/4005650 (2PER PUMP) 7135/6076/310-1753HS/4005650 (2PER PUMP) 2475 6080 7382.3.C.WF) 230/12. MINI JET 212-0300. 218-4010. 718-6960. UNION) 20A GFCI W. 711-4400. 7384 7068 1 1 1 0 1 1 1 240V/48A/60HZ (CS6230-VDS) 230V/12/4. JET (LARGE FACE) 212-0400. CLUSTER STORM JET 212-1550G. # ITEM DESCRIPTION GULF COAST PART # 1 ADJ. 7379 1 24 THERMOWELL 7380 1 25 26 SPA SIDE CONTROL. 212-8147S 2 6 POLY STORM ROTO JET 212-0400. 210-6817S 0 11 WHIRLPOOL JET 212-2010G. FT FILTER CARTRIDGE 817-3501 0 19 PILLOW 12" 3012 3 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 100" X 100" GR 7021100100 1 23 SPA FLOOR DRAIN WITH VALVE 7381. P.5. FACE PLAT E G. 212-7927S 4 10 JUMBO STORM JET 711-0090. 711-4400.918 INTERIOR & PLUMBING PARTS 240/48/60 60 REF. CORD. FT. 212-7937S 10 5 POLY STORM ROTO JET (LARGE FACE) 212-0400. CORD BLOWER OZONE GENERATOR OWNER'S MANUAL 6099. UNION) P2 ASSEMBLY (MOTOR. 218-6680.C. 212-8167S 2 4 MINI ROTO JET 212-0300. 212-2067S 1 12 AIR CONTROL 660-3587(660-4407) 4 13 HI-FLO SUCTION 10-6764(GREY) 3 15 LIGHT ASSEMBLY 3111 1 510-6547HS. OVERLAY G. 711-6900. 218-5150. Keep your invoice in a safe and accessible place.WARRANTY CLAIMS IMPORTANT! Gulf Coast Spa Manufacturers is dedicated to offering you the best in customer satisfaction and service. The warranties will not include any cost of repair incurred by a non-factory-authorized agent. You will be required to give the spa serial number and date of purchase before service can be provided. do not hesitate to call Gulf Coast for more details. Be sure to read the warranty to ensure you understand what you are entitled to in terms of service. The unique 8-digit spa serial number is located on the cover of your owner’s manual and/or on a faceplate affixed to the cabinet panel near the drain valve. The warranty is a manufacturer's warranty and is included in this manual. This does not include mileage or travel charges depicted by your authorized Gulf Coast Spa service company. Serial Number Locations CONDITIONS OF WARRANTIES: All warranties provided hereunder extend only to the original consumer purchaser of the spa if purchased and installed within the boundaries of the United States or Canada and terminate upon transfer of ownership from original consumer purchaser. the parts must be returned to the manufacturer at the cost of the consumer if beyond the boundaries set forth in the warranty card from the date of the original spa purchase. The warranties will not include any shipping cost and/or taxes incurred. All repairs will be made in accordance with the warranty card. If you have any questions whatsoever. SPECIAL NOTE: When calling for service. it is imperative to have your sales invoice in hand to expedite the servicing of your spa. 26 . Failure due to an improper electrical installation will not be covered under the terms of the warranty. To obtain service. No Agent. modify. or any permanent deck or other custom fixture. you have read and understand the Owner’s Manual in its entirety Customer Address Dealer City Dealer Address State City ZIP ZIP Daytime telephone Date Date of purchase Customer Signature E-mail address 27 . A Gulf Coast authorized service representative will correct the defect subject to the terms and conditions contained herein. improper installation. but are not limited to any surface that the spa is placed on or near (i. etc. To ensure proper warranty performance. Lifetime Warranty against permeable leakage of water due to defect in the Fiberglass Laminate. Performance of any Lifetime warranties does not include any shipping or handling fees associated. This limited warranty applies only to the original purchaser and terminates with any transfer of ownership. and will repair or replace the shell at our option if any of the following occurs: 1.cut here -----------------------------------------------cut here------------------------ Spa Model Spa Serial Number Customer Name By signing this Warranty Card. expenses or damages. Service Company or other party is authorized to change.) Gulf Coast extends to the original purchaser Five (5) years parts warranty for all mechanical and solid-state components (prorated after the second year). are valid. (727) 573-9888. This limited warranty does not apply to any spa used for commercial. The spa owner is required to provide adequate access to the spa for any repair or inspection. warrants only Gulf Coast manufactured acrylic spa shells. or above 110 degrees Fahrenheit. or any of its representatives be held liable for injury to any person or damage to any property however arising. Lifetime Warranty for Portable Spas Gulf Coast Spa Manufacturers Inc. blistering. The service representative may assess reasonable travel charges during inspection or repairs. The spa owner shall be responsible for all costs for the removal of the defective spa and delivery and installation of the replacement spa. Gulf Coast warrants to the original buyer of its spa shell. No other warranties expressed or implied. fading or delaminating of the surface for a period of Ten (10) years. or extend the terms of this Warranty in any manner.Gulf Coast Spa Manufacturers Inc. including but not limited to shipping charges.e. 2. Under no circumstances shall Gulf Coast.. or special consequences concerning the replacement or removal of the spa. Dealer. 2004 and supersedes all previous warranties printed or implied. This warranty applies to Gulf Coast spas purchased after January 1. An authorized Gulf Coast representative must perform all warranty service. 073003 IMPORTANT WARRANTY INFORMATION The warranty card MUST be filled out completely and mailed within Ten (10) days of purchase to validate warranty ------------------------cut here-----------------------------------------. prorated after the first year. spa water temperature below 33 degrees Fahrenheit. Unauthorized performance of service is not covered and shall void all warranties. cabinets and equipment assembled at a Gulf Coast manufacturing facility. Lifetime Warranty against defects in material and workmanship on PVC Fittings and Hoses. you must notify Gulf Coast upon discovery of defect. 3. Improper electrical installation shall void all warranties. which may include. which vary from state to state. Gulf Coast warranty does not cover failures resulting from neglect or misuse. improper use of spa chemicals or cleaners containing solvents. carpet. rental or club purposes. This warranty gives you specified legal rights and you may have other rights.) that can be damaged by water or chemicals. wood. Gulf Coast shall not be liable for loss of use of the spa or other incidental or consequential costs. that the shell is free of defects in material and workmanship. (Cracking. Lifetime Warranty of Heater Element. Labor is included for Two (2) years from the date of purchase. GulfCoastSpas. N. Clearwater. FL 33760 www._________________________ Stamp _________________________ _________________________ (Return Address) 11620 54th St.com .
Copyright © 2024 DOKUMEN.SITE Inc.