GS32Q01B10-31E ProSafe-RS Safety Instrumented System Overview (for Vnet IP)

March 28, 2018 | Author: Juan Perez | Category: Network Switch, Power Supply, Computer Network, Optical Fiber, Graphics Processing Unit


Comments



Description

<<Contents>> <<Index>>General Specifications GS 32Q01B10-31E ProSafe-RS Safety Instrumented System Overview (for Vnet/IP) [Release 3]  GENERAL The ProSafe-RS is a Safety Instrumented System that is certified by the German certification organization, Technische Überwachungs-Verein (TÜV) to meet Safety Integrity Level (SIL) 3 specified in IEC 61508.  COMPONENTS AND SOFTWARE The ProSafe-RS system is composed of the Safety Control Station (SCS), the Safety Engineering PC (SENG). ProSafe-RS communicates with each of those equipment via Vnet/IP control network and Ethernet. The SCS performs safety control, and the SENG performs engineering and maintenance for the SCS. The ProSafe-RS can be integrated with the CENTUM VP and CENTUM CS 3000 R3 (hereinafter, “VP/CS 3000”), an integrated production control system. The SCS can be operated and monitored by the HIS (human interface station) of the VP/CS 3000. For specifications regarding the VP/CS 3000, refer to its general specifications. For specifications in case of integrating the ProSafe-RS with the FAST/TOOLS, refer to the general specifications (GS 32Q04D20-31E) for the FAST/TOOLS Integration Engineering Package. For specifications regarding the system on V net, refer to the general specifications (GS 32Q02B10-31E) for ProSafeRS Safety Instrumented System Overview (for V net).  Safety Engineering PC (SENG) To configure the ProSafe system, the CHS5100 Safety System Generation and Maintenance Package needs to be installed on a PC (IBM PC/AT-compatible computers). The SENG performs engineering and maintenance. For details on the SENG’s functions, refer to the general specifications (GS 32Q04C10-31E) for the CHS5100 Safety System Generation and Maintenance Package.  Safety Control Station (SCS) The SCS offers a safety control functions, the sequence-of-events-recorder (SOER) function, the VP/CS 3000 integration function, and the Modbus connection function which interfaces the SCS with another system. The SCS consists of a safety control unit (CPU node) and safety node units (I/O node). There are two types of CPU nodes: a standard safety control unit and a wide range temperature safety control unit (equipped with a fan unit). The CPU node can be connected with the I/O node via the ESB bus. I/O modules can be mounted both on the CPU node and I/O node alike. SCS with CPU node connectable to 13 I/O nodes SSC60S-S: Safety Control Unit (for Vnet/IP, Rack Mountable Type, Standard Type) SSC60D-S: Duplexed Safety Control Unit (for Vnet/IP, Rack Mountable Type, Standard Type) SSC60S-F: Safety Control Unit (for Vnet/IP, Rack Mountable Type, Wide Range Temperature Type) SSC60D-F: Duplexed Safety Control Unit (for Vnet/IP, Rack Mountable Type, Wide Range Temperature Type) For details, refer to the general specification “Safety Control Units for Vnet/IP (Rack Mountable Type), Duplexed Safety Control Units (Rack Mountable Type)” (GS 32Q06D10-31E). SCS with CPU node connectable to 9 I/O nodes SSC50S-S: Safety Control Unit (for Vnet/IP, Rack Mountable Type, Standard Type) SSC50D-S: Duplexed Safety Control Unit (for Vnet/IP, Rack Mountable Type, Standard Type) SSC50S-F: Safety Control Unit (for Vnet/IP, Rack Mountable Type, Wide Range Temperature Type) SSC50D-F: Duplexed Safety Control Unit (for Vnet/IP, Rack Mountable Type, Wide Range Temperature Type) For details, refer to the general specification “Safety Control Units for Vnet/IP (Rack Mountable Type), Duplexed Safety Control Units (Rack Mountable Type)” (GS 32Q06D20-31E). Software CFS1300 Safety Control Functions Package (for SSC60) CFS1100 Safety Control Functions Package (for SSC50) CFS1350 Node Expansion Package (for SSC60) For details, refer to the general specifications “Safety Control Functions Package” (GS 32Q03B10-31E, GS 32Q03B20-31E). Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan GS 32Q01B10-31E ©Copyright July 2011 (YK) 5th Edition Apr. 1, 2013 (YK) Copyright © 2011. refer to the general specification below. Item Electronic Document Model CHS5400 General Specification GS 32Q01W10-31E All Rights Reserved. Items CENTUM VP/CS 3000 Integration Engineering Package SOE Viewer Package SOE OPC Interface Package Access Control and Operation History Management Package FAST/TOOLS Integration Engineering Package Models CHS5200 CHS2100 CHS2200 CHS5170 CHS5700 General Specifications GS 32Q04D10-31E GS 32Q02D10-31E GS 32Q05D10-31E GS 32Q04D30-31E GS 32Q04D20-31E  Document For details. 28. Items Safety Node Unit I/O Modules Communication Modules Unit for Optical Bus Repeater Module Optical ESB Bus Repeater Module Cables Vnet/IP Interface Card Power Supply Bus Unit VI702 AEPV7D ALR111. The Vnet/IP domain refers to the Vnet/IP system area connected by L2SW. For communication among Vnet/IP domains. SNT411. VP/CS 3000 engineering function is required. SNT511 SNB10D Models General Specifications GS 32Q06K10-31E GS 32Q06K20-31E GS 32Q06K50-31E. GS 33P06B11-31E GS 33K50K41-50E  Layer 2 Switch (L2SW) L2SW relays communications among devices connected to the Vnet/IP network. refer to the general specifications for the respective hardware below. GS 32Q06L16-31E GS 32Q06M10-31E GS 33K50C10-50E.  Related Software For details. The control data can be sent and received in both ways between the Vnet/IP and V net domains.<<Contents>> <<Index>> 2  Peripheral Equipment For details. Connect Vnet/IP station to SNTP server for synchronizing its time to the Universal Time. In the Vnet/IP domain. and vice versa. GS 32Q06K51-31E GS 32Q06K11-31E GS 32Q06L15-31E.  SNTP Server SNTP server performs time synchronization via networks. AVR10D Duplexed V net Router (duplexed communication modules and duplexed power supply modules) For V net router engineering. ALR121. refer to the general specifications for the respective software application below. 2012-00 . is enabled. For more details. Yokogawa Electric Corporation GS 32Q01B10-31E Nov. ALE111 SNT10D SNT401. Coordinated (UTC). use L2SW with 1 Gbps communication speed.  V net Router V net router connects and transmits control communications between the Vnet/IP and V net domains.  Layer 3 Switch (L3SW) L3SW relays communications among Vnet/IP domains. use L3SW with 1 Gbps communication speed. SNT501. Control and monitoring of the safety control stations in the other domain. refer to the general specifications “Duplexed V net Router” (GS 33K50D10-50E). Copyright © 2011. When SCS is in operation. routers. 2011-00 .) All Rights Reserved.ai Figure Example of Minimum Configuration of the System  Maximum System Configuration Vnet/IP domain: Maximum 16 domains Vnet/IP station: Maximum 64 stations per domain (SCS.<<Contents>> <<Index>> 3  SYSTEM CONFIGURATION  Minimum System Configuration The minimum system configuration is composed of the following equipment: SENG: 1 unit SCS: 1 unit Layer 2 switch: 2 units SENG BUS1 Layer 2 switch BUS2 Layer 2 switch BUS1 BUS2 SCS Even in the minimum configuration of 1 unit of SCS and SENG each. SENG and AVR10D) General Ethernet equipment: Maximum 124 units per domain (PC. two switches for two busses are required. one Layer 2 switch per bus and therefore. at least one of the Layer 2 switches must be activated. etc. Yokogawa Electric Corporation GS 32Q01B10-31E July 21. F01E. SENG software. refer to the system specifications for the VP/CS 3000 (GS 33K01A10-50E. SSC60S/SSC60D CENTUM VP CENTUM CS 3000 R4.02 or later is installed in the same PC. The number of safety control stations are not included in that of control stations of the LHS1100 Standard Operation and Monitoring Function. the upper level project must be CENTUM VP or CS 3000. FCS and HIS engineering are performed from ENG which is a PC for engineering.ai L3SW: Layer 3 Switch Figure Example of the ProSafe-RS and VP/CS 3000 Integration System In the integration of ProSafe-RS and VP/CS 3000.08 or later When a project including SCS is connected as lower level project by using “Multiple Project Connection Package”(GS 33K05K20-50E. *1: When ProSafe-RS R2. the following system revision is required for the HIS. Copyright © 2011.09 or later SSC50S/SSC50D R4. SENG functions and ENG functions. ProSafe-RS must be R2.03 or later. 2011-00 . For operating and monitoring SCS on HIS. Engineering of CENTUM VP/CS 3000 integration function is performed from both SENG and ENG. Yokogawa Electric Corporation GS 32Q01B10-31E July 21. please contact our sales representative or your local distributor. GS 33Q02S10-31E). ENG software and HIS software can be installed together in a single PC(*1) or separately in several PCs. SCS engineering is performed from SENG.01 or later R3. In the integration of ProSafe-RS R3 and CS 3000.xx and CENTUM VP R4. All Rights Reserved.<<Contents>> <<Index>> 4 Ethernet ProSafe-RS SNTP Server HIS ENG SENG  Example Configuration of CENTUM VP/CS 3000 Integrated System Other Vnet/IP domains L3SW x 2 Vnet/IP FCS FCS SCS V net router UGS Modbus Third-party system STARDOM Other V net domains Boundary Router Remote Network F02E.02 or later R3. GS 33P01B10-31E). or SENG functions and HIS functions cannot be installed in the same PC. For more detail. Modbus Communication Communication Module Serial Communication Module Ethernet Communication Module X: –: Supported Not supported Subsystem Communication Function X – Modbus Slave Communication Function X X The subsystem communication and modbus slave communication functions can be executed simultaneously. • When more than one Vnet/IP domain is connected. 28. Yokogawa Electric Corporation GS 32Q01B10-31E Nov. the number of units is counted as 2).  Setting IT security function The security can be enhanced through the automatic setting at IT security function of ProSafe-RS.<<Contents>> <<Index>> 5  Example of the Connection with Another System ProSafe-RS can communicate with other systems through Modbus connections. To perform this operation. subsystem communication function and modbus slave communication function cannot coexist on one serial communication module. The following functions are available using an interference-free serial communication module or Ethernet communication module. 2012-00 . An example of the system configuration is shown below: Safety Engineering PC SENG Vnet/IP Layer 2 switch Layer 2 switch ProSafe-RS SCS The other system (DCS. the engineering function of the VP/CS 3000 is needed. Copyright © 2011. however. • Modbus slave communication function SCS can communicate as a slave station when the other system acts as a Modbus master. All Rights Reserved.) Modbus Communication F03E.ai  Cautions for System Configuration • The maximum number of SCS units to which Inter-SCS safety communication is possible from one SCS unit is 16 (when any two SCS units perform bidirectional communication each other. AVR10D (Duplexed V net Router). etc. For communication specifications. • Subsystem communication function SCS can communicate as a master station when ProSafe-RS acts as a Modbus master. the integrated CENTUM VP needs to be R4. refer to “Safety Control Functions Package (GS 32Q03B10-31E)” and “ALR111/ ALR121 Serial Communication Module (GS 32Q06K50-31E)” or “ALE111 Ethernet Communication Module (GS 32Q06K51-31E)”.01 or later. PRM needs to be R3.02 or later. • For the ProSafe-RS system to employ. the engineering function of VP/CS 3000 is required. ai Figure Network Configuration SSC60/SSC50 Safety Control Unit is connected with 100Base-TX with 1 Gbps L2SW (*1) in Vnet/IP domain. Vnet/IP is a gigabit Ethernet-based control network. Copyright © 2011. Vnet/IP is a dual-redundant control network. Yokogawa Electric Corporation GS 32Q01B10-31E July 21.<<Contents>> <<Index>> 6  NETWORK SPECIFICATIONS  Vnet/IP The ProSafe-RS uses Vnet/IP and Ethernet for communications among configured devices. however. when the Bus 1 fails. As redundant Vnet/IP bus is separated as a subnet independent by bus. 2011-00 . Number of layer 2 switches to be equipped between stations in the same domain is maximum 7 levels (multiple cascade connection available). *1: Maximum communication bandwidth of SSC60/SSC50 is 100 Mbps. L2SW must be equipped in each bus. Bus 1 is normally used for control communication to transmit control data. FCS or HIS are connected with 1 Gbps. it automatically switches its communication path and Bus 2 continues the control communication without stopping. link transmission Link transmission period: 100 ms All Rights Reserved. Please use 1 Gbps L2SW which can connect with 100 Mbps equipment. consisting of Bus 1 and Bus 2. and other equipment like SENG. Control Communication Communication method: Read/write communication. and provides real-time communication with high reliability. Do not connect any two stations in a way that there exist more than one communication path. 100 m Wide area connection via dedicated line are also possible. message communication. Following is an outline of network connection of ProSafe-RS Vnet/IP system. SENG HIS/ENG 1000Base-T Max. Up to seven levels of layer 2 switch BUS1 L3SW Vnet/IP domain L3SW Vnet/IP domain V net router V net domain L2SW L2SW L2SW BUS2 L2SW Vnet/IP domain L2SW L2SW BCV 100Base-TX V net domain SSC60/SSC50 L2SW : Layer 2 switch L3SW : Layer 3 switch F04E. Each redundant Vnet/IP bus is connected via each layer 3 switch to other domains.30 to R1.00 3    – – 4 – – –   5 – – –   Approved Inter SCS Safety Communication available Inter SCS Safety Communication unavailable (upgrade revision to R1. SSC50 and V net Router.02 or later) Not available SSC10 is the model name of SCS on V net. The inter-SCS safety communication can be used to construct a safety loop up to SIL 3 (Safety Integrity Levels) for multiple SCSs via the Vnet/IP or V net. BCV/CGW junctions in the path are up to 2) 3: SSC10–(V net)–AVR (V net Router)–(Vnet/IP)–SSC60/SSC50 • Between SSC10 and SSC60/SSC50 via AVR (V net Router) (however.50 2    – – 3 – – –   6 – – –   1    – – R1.02. 1000 BASE-LX standard defines the transmission distance as up to 5 km for a single mode optical fiber. Use AVR10D style code S3 or later and the engineering function of VP R5. Copyright © 2011. Connecting Vnet/IP domains Vnet/IP domains are connected by layer 3 switches.00 3    – – 4 – – –   5 – – –   2 – – – – – SSC60 R2.01.3ab) 1000BASE-LX (IEEE802. 28.02. 1: SSC10(*1)–(V net)–SSC10 • In the same V net domain • Between V net domains in which BCV/CGW’s junctions are up to 2 2: SSC10–(V net)–AVR (V net Router)–(Vnet/IP)–AVR (V net Router)–(V net)–SSC10 • Between SCSs which includes Vnet/IP in the path (however.02.01. BCV/CGW junctions in the path are up to 2) Receiving end (Consumer) Sending end (Producer) communication path R1. To connect Vnet/IP domains.00 to R3. contact Yokogawa for details.00 to R3. Yokogawa Electric Corporation . VP/CS 3000 system Engineering function is required. 2012-00 All Rights Reserved.3ab) 1000BASE-T (IEEE802.01 or later.30 to R1.00 to R3.02.00 SSC50 R1.03. The communication path is shown below.00 2    – – 3 – – –   6 – – –   1    – – SSC10 R1.00 to R3.01.02.01.02.01.02.3z) Speed 100 Mbps (*1) 1 Gbps 1 Gbps 1 Gbps 1 Gbps 1 Gbps Maximum Distance 100 m 7 Between layer 2 switches 100 m 5 km (*2) 100 m 5 km (*2) Between a layer 2 switch and a layer 3 switch *1: *2: Applicable for SSC60.3z) 1000BASE-T (IEEE802.3u) 1000BASE-T (IEEE802.00 2    – – 3 – – –   6 – – –   2 – – – – – SSC50 R1.<<Contents>> <<Index>> Transmission specifications Network topology: Star topology Transmission redundancy: Dual-redundant (for control network communication only) Transmission cable: Unshielded twist-pair (UTP) with enhanced category 5 or superior Connection Between component and a layer 2 switch Cable Standard 100BASE-TX (IEEE802.50 R1.00 SSC10 R1.01.00 to R3.00 SSC60 R2.00 to R3.3ab) 1000BASE-LX (IEEE802. refer to ProSafe-RS Safety Instrumented System Overview (for V net) (GS 32Q01B20-31E). In case further length is required. Communications between Instruments Distance between the two arbitrary stations in a domain: Maximum 40 km One level (a pair) of media converters can be connected in between the instruments. BCV/CGW junctions in the path are up to 2) 4: SSC60/SSC50–(Vnet/IP)–SSC60/SSC50 (Layer 3 switch junctions in the path are up to 15) 5: SSC60/SSC50–(Vnet/IP)–AVR(V net Router) (*2)–(V net)–AVR (V net Router) (*2)–SSC60/SSC50 • Between SCSs which includes V net in the path (however. GS 32Q01B10-31E Nov.03.02.00 : : –: *1: *2: 1    – – R1.02. For SSC10. Do not connect any two domains in a way that there exist more than one communication path.02. BCV/CGW junctions in the path are up to 2) 6: SSC60/SSC50–(Vnet/IP)–AVR (V net Router) (*2)–(V net)–SSC10 • Between SSC60/SSC50 and SSC10 via AVR (V net Router) (however. Inter-SCS Safety Communication SCS can perform inter-SCS safety communication with other SCSs in the same domain as well as in different domains. Yokogawa Electric Corporation GS 32Q01B10-31E July 21. 10 m SSB401 SNB10D SNB10D ESB bus SNB10D ESB bus F06E. Node Expansion Package (for SSC60)” (GS 32Q03B10-31E). Up to 13 I/O nodes can be connected to SEC402 as a total of upper and lower ports. and other general-purpose Ethernet instruments. Communication Protocol Based on IEEE802. ESB bus: Max. For details. The number of Connectable Units Using SEC402 ESB bus coupler module. *1: To connect 10 or more I/O nodes. Using SEC401 ESB bus coupler module. Following is an overview of connection of ESB buses using SEC402 in SSC60D.ai Figure Connection Overview of SEC402 ESB Bus Coupler Module All Rights Reserved. refer to “Safety Control Functions Package (for SSC60).3  ESB Bus ESB buses are I/O communication buses that connect the safety node units (I/O nodes) with the safety control unit (CPU node) of the SCS. up to 9 I/O nodes can be connected to CPU node (SSC60/SSC50). (*1) SEC402 has two ports to connect ESB bus. Ethernet communication is usually performed via an Ethernet card mounted a PC or a server. CFS1350 Node Expansion Package is required. 2011-00 . HIS/ENG for CENTUM. Transmission Network Specifications Network topology: Bus topology Transmission channel redundancy: dual-redundant Network speed: 128 Mbits/sec Network cable: dedicated cable (YCB301) Maximum transmission distance: 10 m (ESB) (*1) *1: Length of ESB buses must be 10 m or shorter each from upper and lower port of SEC402.<<Contents>> <<Index>> 8  Ethernet Ethernet is a network used for file transfer and information communication among SENG. Copyright © 2011. up to 13 I/O nodes can be connected to CPU node (SSC60). 10 m SEC402 SSC60D Upper ESB bus Lower ESB bus SNB10D ESB bus: Max. Up to 9 I/O nodes can be connected to each of upper and lower port. 1) Number of cores: 2 Maximum transmission distance is 5 km in earlier than R1. refer to “Optical ESB Bus Repeater Module 5 km to 50 km (for SSC60/SSC50)” (GS 32Q06L15-31E). SNT511). For the other restrictions about the length of fiber-optic cable. 2011-00 . SNT511): 50 km (*2) Network topology: chain type and star type (Chain type and star type can be mixed.10 m Connect with fiber-optic Cables: Two stages max. Network cable: Fiber-optic cable (*1) Maximum transmission distance using Optical ESB Bus Repeater (SNT411.10 m CPU Node ESB bus I/O Node I/O Node Fiber-optic Cable Max. IEC 60793-2-50B1. F05E. Copyright © 2011.00. SNT411. SNT501. ESB bus: Max. extension distance of fiber-optic cables ESB bus I/O Node I/O Node I/O Node I/O Node Connect with fiber-optic Cables: 1st stage Fiber-optic Cable ESB bus I/O Node I/O Node I/O Node ESB bus: Max.) *1: Fiber-optic Cable Specifications Connector: LC type (IEC 61754-20 compliant) Recommended cable: Silica-Based Single-Mode Fiber (JIS C6835 SSMA -9.ai Figure Overview of ESB Bus and Optical ESB Bus Repeater All Rights Reserved.03.3/125. 9 *2: Following is an overview of connection of Fiber-optic cable and ESB buses using Optical ESB Bus Repeater Modules in CPU node.<<Contents>> <<Index>> ESB Bus can be extended by using Optical ESB Bus Repeater Module (SNT401. Yokogawa Electric Corporation GS 32Q01B10-31E July 21. 77 million colors) Minimum WXGA+ (1440 x 900) resolution. free space of minimum 100 GB Minimum SXGA (1280 x 1024) resolution.0 in hardware • 32 bits per pixel • 128 MB Graphics memory 1 slot is used for Vnet/IP interface (*1) DVD-ROM For Windows Vista CPU Main memory Hard disc Required Required Required Recommended Required For wide screen Required Required Required Required Display Graphics Expansion slot Mouse Optical disc drive *1: VI702 is required for Vnet/IP interface card. GS 32Q01B10-31E Nov. True Color (min. Core2 Duo minimum 2. True Color (min.13 GHz Xeon dual core minimum 2. 16. 16. Copyright © 2011.77 million colors) DirectX 9-class GPU(Graphics Processing Unit) that supports • A WDDM(Windows Driver Display Model) Driver • Pixel Shader 2. free space of minimum 100 GB Minimum SXGA (1280 x 1024) resolution.98 GHz 4 GB Free space of minimum 20 GB Free space of minimum 40 GB When the operation history database is stored for access control and operation history management package. Required Required Required Recommended Required For wide screen Required Required Required Required Xeon dual core minimum 2.<<Contents>> <<Index>> 10  SYSTEM REQUIREMENTS  Hardware Requirements The Standard Operation and Monitoring Function runs on a computer (IBM PC/AT-compatible) which meets the following requirements: For Windows 7 CPU Main memory Hard disc Required Required Required Recommended Required For wide screen Required Required Required Required Core2 Duo minimum 2. Yokogawa Electric Corporation .0 GHz 4 GB Free space of minimum 20 GB Free space of minimum 40 GB When the operation history database is stored for access control and operation history management package. 28.77 million colors) DirectX 9-class GPU(Graphics Processing Unit) that supports • A WDDM(Windows Driver Display Model) Driver • Pixel Shader 2. True Color (min.77 million colors) Minimum WXGA+ (1440 x 900) resolution.0 GHz Minimum 2 GB Free space of minimum 20 GB Free space of minimum 40 GB When the operation history database is stored for access control and operation history management package. 16.0 in hardware • 32 bits per pixel • 128 MB Graphics memory 1 slot is used for Vnet/IP interface (*1) DVD-ROM Display Graphics Expansion slot Mouse Optical disc drive *1: VI702 is required for Vnet/IP interface card.13 GHz Xeon dual core minimum 2. free space of minimum 100 GB Minimum SXGA (1280 x 1024) resolution. 16. 2012-00 All Rights Reserved.0 in hardware • 32 bits per pixel • 128 MB Graphics memory 1 slot is used for Vnet/IP interface (*1) DVD-ROM For Windows Server 2008 R2 CPU Main memory Hard disc Display Graphics Expansion slot Mouse Optical disc drive *1: VI702 is required for Vnet/IP interface card. True Color (min. 16.77 million colors) DirectX 9-class GPU(Graphics Processing Unit) that supports • A WDDM(Windows Driver Display Model) Driver • Pixel Shader 2. True Color (min. 16. True Color (min.77 million colors) Minimum WXGA + (1440 x 900) resolution.  Software Requirements Windows 7 Professional 64 bit SP1 X Windows Vista Business Edition 32 bit SP2 X Windows Server 2008 Standard Edition R2 64 bit SP1 X Windows Server 2008 Standard Edition 32 bit SP2 X Windows Windows Server 2003 Server 2003 Standard Standard Edition R2 Edition 32 bit SP2 SP2 – (*1) – (*1) ProSafe-RS Release No. R3. All Rights Reserved. 2012-00 . Copyright © 2011.00 X: Compatible –: Not compatible Note: Service Pack is abbreviated as SP (Example: SP1 stands for Service Pack 1). True Color 1 slot is used for Vnet/IP bus interface (*1) DVD-ROM Display Expansion slot Mouse Optical disc drive *1: VI702 is required for Vnet/IP interface card.0 GHz Minimum 2 GB Free space of minimum 20 GB Free space of minimum 40 GB When the operation history database is stored for access control and operation history management package. Yokogawa Electric Corporation GS 32Q01B10-31E Nov.01.02.<<Contents>> <<Index>> For Windows Server 2008 CPU Main memory Hard disc Required Required Required Recommended Required For wide screen Required Required Required 11 Core2 Duo minimum 2. True Color Minimum WXGA + (1440 x 900) resolution. 28. *1: The Windows Server 2003 is applicable as the file server of the project database. free space of minimum 100 GB Minimum SXGA (1280 x 1024) resolution.13 GHz Xeon dual core minimum 2.00 to R3. bus repeaters.04 G3 (standard) Electric field Noise Static electricity Continuous vibration Vibration Non-continuous vibration Seismic Transportation Impact Altitude 10 V/m maximum (80 MHz to 1 GHz) 4 kV or less (direct discharge) 8 kV or less (aerial discharge) Amplitude: 1. Temperature Normal operation Transportation/storage Humidity Temperature change Normal operation Transportation/storage During operation Transportation/storage Voltage range Frequency Power supply Distortion factor Crest factor Momentary failure DC power supply ripple rate Withstanding voltage Insulation resistance Grounding Dust Corrosive gas All Rights Reserved. 11 ms 2000 m above sea level or less When packaged Excluding SRM53D/SRM54D/ SBM54D Between power & ground terminals Between power & ground terminals 5 to 85 % RH when the SRM53D/ SRM54D/SBM54D is mounted. Copyright © 2011. Item Specifications –20 to 40 °C (basic safety control unit) –20 to 70 °C (wide range temperature safety control unit and safety node unit) –40 to 85 °C 5 to 95 % RH (non-condensing) 5 to 95 % RH (non-condensing) Within ±10 °C/h Within ±20 °C/h 100 to 120 V AC: –15 % to +10 % 220 to 240 V AC: –15 % to +10 % 24 V DC: –10 % to +20 % 50/60 Hz ± 3 Hz 10 % or less 100 V system: 118 V or larger 220 V system: 258 V or larger 20 ms or less (when receiving the rated AC voltage) 1 % P-P maximum 1500 V AC for 1 minute (for 100 to 120/220 to 240 V AC) 20 M ohms at 500 V DC 100 ohms or less.5 mm (5 Hz to 9 Hz) Acceleration: 9. and I/O modules. Remarks 0 to 60 °C when the ALR111-S1/ ALR121-S1 is mounted. refer to their respective general specifications.9 m/s2 or less Horizontal: 4. 0 to 60 °C when the ALE111-S1 is mounted.<<Contents>> <<Index>> 12  CRITERIA FOR THE INSTALLATION ENVIRONMENT The table below presents the criteria for the environment where the safety control unit and the safety node unit are to be installed.9 m/s2 or less Vertical: 9. independent grounding Maximum of 0. Yokogawa Electric Corporation GS 32Q01B10-31E Apr.8 m/s2 (9 Hz to 150 Hz) Acceleration: 4.75 mm (5 Hz to 9 Hz) Acceleration: 4.3 mg/m3 ANSI/ISA S71.9 m/s2 (9 Hz to 150 Hz) Amplitude: 3. For PCs. 2013-00 . 1. optical bus repeaters. 0 to 70 °C when the ALR121-SB is mounted.8 m/s2 or less 147 m/s2. SBD3D and SBD4D. IEC 61511-1. *6: For a rack-mounted device to comply with safety standards and EMC standards. *5). [CSA] CAN/CSA-C22. 3825 HD Amersfoort. 220-240 V AC and 24 V DC power supply) (*8) EN 61000-6-2 (for 100-120 V AC. *2: The 24 V DC and 48 V DC power supply lines from the field power supply to DI and DO needs to be 30 m or less. a power supply device with harmonic wave restraining capability or an external device with such a capability (e. NFPA72 Safety Standards (*6. *8: A Class A hardware device is designed for use in the industrial environment. except for SBD2D. B. *5: The 24 V DC and 48 V DC power supply lines from the field power supply to DI and DO needs to be 10 m or less. an external device. NFPA85. *3: When 24 V DC (SPW484) is used for the system power supply. is needed. refer to the ProSafe-RS Explosion Protection (TI 32S01J30-01E). 220-240 V AC and 24 V DC power supply) Standards for Hazardous Location Equipment (*10) For selecting the right products for explosion protection. refer to the ProSafe-RS Installation Guidance (TI 32S01J10-01E). *12) [CSA] CAN/CSA-C22. EN 50156-1. [FM Non-Incendive] Class I Division 2 Groups A. *9: To restrain the power supply’s harmonic waves. *4: The clamp filter (A1193MN) needs to be added to the V net cable. 1.2 No. 220-240 V AC and 24 V DC power supply) (*1) EN 61000-3-2 (for 220-240 V AC power supply) (*9) EN 61000-3-3 (for 220-240 V AC power supply) [C-Tick Marking] EN 55011 Class A Group 1 (for 220-240 V AC and 24 V DC power supply) [KC Marking] Korea Electromagnetic Conformity Standard (for 100-120 V AC. *6) [CE Marking] EMC Directive EN 55011 Class A Group 1 equivalent (for 100-120 V AC. *10: See the “List of Application Standard. please refer to TI 32S01J30-01E without fail. IEC 62061. For details.V. SBD2D. 220-240 V AC and 24 V DC power supply) [Type “n”] (*11) II 3 G Ex nA IIC T4 Gc (*13) II 3 G Ex nA nC IIC T4 Gc (*14) EN 60079-0:2009 EN 60079-0:2012 EN 60079-15:2010 (for 24 V DC power supply) Marine Standards (*10) ABS (American Bureau of Shipping) BV (Bureau Veritas) Lloyd’s Register Note: According to the New Approach Directive.) Representative office in EU Community: Yokogawa Europe B. Copyright © 2011. a UPS should be attached externally. Japan. *2. *14: Applied for the below products. 220-240 V AC and 24 V DC power supply) (*7) EMC Conformity Standards (*1. Musashino-shi. Yokogawa Electric Corporation GS 32Q01B10-31E Apr. The Netherlands. Tokyo 1808750. 2013-00 . (Euroweg 2. For details. for example the requirements of cabinet must be met. the manufacturer and the representative office in EU are indicated below: Manufacturer: YOKOGAWA Electric Corporation (2-9-32 Nakacho. SBD3D and SBD4D All Rights Reserved. Please use this device in the industrial environment only. C and D Temperature Code T4 Class 3600: 1998 Class 3611: 2004 Class 3810: 2005 (for 100-120 V AC. active filter) needs to be connected. *3) Functional Safety Standard IEC 61508 Application Standards (*1) EN 54 (*4).2 No. such as a lightning arrester.g. *12: For ensuring all the hardware devices to satisfy the safety standards. EN 298 (*3. it needs to be housed in a lockable metal cabinet.) *1: For surge immunity.<<Contents>> <<Index>> 13  APPLICABLE STANDARDS The hardware components of the ProSafe-RS comply with the standards below.” *11: To be compatible with Type “n”.61010-1 (for 100-120 V AC power supply) [CE Marking] Low Voltage Directive EN 61010-1 (for 100-120 V AC. the dedicated breakers in the power supply distribution board must conform to the following specifications. *7: The analog inputs of this system fall into Measurement Category I of IEC 61010-1. *2.5 or UL 489 [CE Marking] EN 60947-1 and EN 60947-3 *13: Applied for products complied with Type “n”. PLC Standard IEC 61131-2 (*1. SDV531-LC does not comply with Marine Standards. SSC60D-S and SSC60S-S do not comply with Marine Standards. STK4A Style code S3 does not comply with Marine Standards. STB4D. STA4S. SPW481. SPW482. SSB401 Including SCCC01. Including SCCC01. Including SPW481.<<Contents>> <<Index>> Table List of Applicable Standard (1/2) Standards for Hazardous Location Equipment (*1) Marine Standards (*2) BV (Bureau Veritas) X (*3) X (*3) X X X X X X X X X X – X X X X X X X X X X X X X X – X X X X X – X X X X X remarks 14 Models SSC60D SSC60S SSC50D SSC50S SNB10D SAI143 SAV144 SAT145 SAR145 SAI533 SDV144 SDV521 SDV526 SDV531 SDV53A SDV541 SCB100 SCB110 SNT10D SNT401 SNT411 SNT501 SNT511 SEC401 SEC402 ALR111 ALR121 ALE111 SDCV01 SEA4D SED2D SED3D SED4D SWD2D SBT4D SBR4D SBA4D SBD2D SBD3D ABS FM Non(American Type “n” Incendive Bureau of Shipping) X X X (*3) X X X (*3) X X X X X X X X X X X X X X X X – X X X X X X X X X X X X X X X X X X X X – X X X X X X X X X X X X – X X X X X X X X X X X X X X X X X X X X – X X X X X X X X X X X X – X X X X X X X X X X X X X X – X X X X X – X X X X X Lloyd's Register X (*3) X (*3) X X X X X X X X X X – X X X X X X X X X X X X X X – X X X X X – X X X X X Including SCP461. STA4D. SPW484 Including SCP451. STK4A Including SCCC01. refer to “ProSafe-RS Installation Guidance (for Vnet/IP) ” (TI 32S01J10-01E). STA4D. 1. 2013-00 . STD4A SDV144-SC does not comply with Marine Standards. Copyright © 2011. Including SCCC01. All Rights Reserved. SPW484 Including SPW481. STA4S. SPW481. Including SCCC01. STA4D. STA4S. Yokogawa Electric Corporation GS 32Q01B10-31E Apr. X: Certified –: Non-Certified *1: For details. STB4S. STD4A SDV531-L complies with Marine Standards from style code S3. SDV521-SC does not comply with Marine Standards. SPW484 Including SCP451. SPW482. SPW484 ALR121-SB does not comply with Marine Standards. STK4A Including SCCC01. SPW482. refer to “Explosion Protection (for ProSafe-RS)” (TI 32S01J30-01E). *3: SSC60D-F and SSC60S-F comply with Marine Standards. SPW484 Including SCP461. SPW482. SCCC02. SPW484. STB4D. SCCC02. SPW481. STB4S. STB4D. *2: For details. SPW482. STB4S. SPW482. STD4A SDV541-SC does not comply with Marine Standards. SPW481. SCCC02. • Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. GS 32Q01B10-31E Nov. 2012-00 . refer to “ProSafe-RS Installation Guidance (for Vnet/IP) ” (TI 32S01J10-01E).<<Contents>> <<Index>> Table List of Applicable Standard (2/2) Standards for Hazardous Location Equipment (*1) Marine Standards (*2) BV (Bureau Veritas) X X X X X X X X X X X X X X X X X X X remarks 15 Models SBD4D SRM53D SRM54D SBM54D VI702 VI701 YCB301 YCB141 YCB111 AKB136 AKB161 AKB331 AKB611 AKB651 KS1 YCB148 YCB146 YCB128 AVR10D ABS FM Non(American Type “n” Incendive Bureau of Shipping) X X X – – X – – X – – X – – X – – X X X X X X X – – X X X X X X X X X X X X X X X X X X X X X X – – X X X X – – X Lloyd's Register X X X X X X X X X X X X X X X X X X X –: Non-Certified X: Certified *1: For details. CENTUM and Vnet/IP are registered trademarks of Yokogawa Electric Corporation. • Windows and Windows Vista are registered trademarks of Microsoft Corporation in the USA and other countries. All Rights Reserved. Copyright © 2011. *2: For details. • Modbus is a registered trademark of Schneider Electric SA. USA. Yokogawa Electric Corporation Subject to change without notice. • Ethernet is a registered trademark of XEROX Corporation.  TRADEMARKS • ProSafe. refer to “Explosion Protection (for ProSafe-RS)” (TI 32S01J30-01E). 28.
Copyright © 2024 DOKUMEN.SITE Inc.