October 2012For the most current product/pricing information on Anvil products, please visit our website at www.anvilintl.com. Mechanical Piping Products b u i l d i n g c o n n e c t i o n s t h a t l a s t North Alabama Pipe Innovators of Pipe Fabrication Equipment B u i l d i n G c o n n e c t i o n s t h At l A s t For over 150 years, Anvil has worked diligently to build a strong, vibrant tradition of making connections — pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior customer service at all levels. We provide expertise and product solutions for a wide range of applications, from plumbing, mechanical, HVAC, industrial and fire protection to mining, oil and gas. Our comprehensive line of products includes: grooved pipe couplings, grooved and plain-end fittings, valves, cast and malleable iron fittings, forged steel fittings, steel pipe nipples and couplings, pipe hangers and supports, channel and strut fittings, mining and oil field fittings, along with much more. As an additional benefit to our customers, Anvil offers a complete and comprehensive Design Services Analysis for mechanical equipment rooms, to help you determine the most effective and cost-efficient piping solutions. At Anvil, we believe that responsive and accessible customer support is what makes the difference between simply delivering products — and delivering solutions. Mechanical Piping Products Durable. Flexible. Safe. Easy to install. Easy to maintain. That’s Anvil’s Gruvlok® product line. Gruvlok gives your building the toughest, simplest, and most adaptable piping system possible. Through a combination of roll-grooving and two-bolt coupling design, this innovative product line joins piping and other components into a single rugged yet flexible system. This makes Gruvlok products ideal for a variety of applications — particularly in tight spaces such as subfloors, UFAD systems, crawlspaces, trenches, and tunnels. Gruvlok products eliminate the need for traditional expansion joints, allowing your system to expand and contract with your needs. With a Gruvlok union at every joint, you have the freedom to make on-site tweaks without altering the overall design of your system. Maintenance is as simple and flexible as installation. Every component in a Gruvlok system is easily replaceable and easily accessed, so that you can make repairs without resorting to a total shut-down. Building Green with Anvil Anvil manufactures an extensive line of products composed of 90% recycled materials, visit www.anvilintl.com for current certificates related to recycled material. Anvil is a member of the United States Green Building Council. Products include: • Gruvlok® Couplings, Fittings, and Flanges • Anvil® Cast and Malleable Threaded Fittings • Anvil Cast Iron Flanged Fittings • Anvil Pipe Hangers and Supports • Merit ® Tee-Lets and Drop Nipples • Beck Welded Pipe Nipples New 3-D CAD Library 7000 Coupling 7001 Coupling 7003 Coupling Anvil's Gruvlok product line is now available in 3-D CAD Models, as well as the standard 2-D drawings, at www.anvilintl.com. Anvil also offers downloadable Master Format 3 Part Specifications. 7010 Coupling 7011 Coupling 7012 Coupling GL-6.11 IntroductIon table of contents introduction Gruvlok® Pictorial Parts Index..................................6-12 Agency Approvals ...............................................................13 Gruvlok – The Engineered Coupling ....................... 14 The Gruvlok Piping Method..........................................15 Gruvlok Couplings for Grooved-End Pipe............ 16 Coupling Data Chart Notes...........................................17 couplinGs for Grooved-end pipe Fig. 7401 Rigidlok® Coupling ....................................18-19 Fig. 7401-2 Rigidlok® Coupling.....................................20 Fig. 7001 Standard Coupling ...................................21-22 Fig. 7001-2 Standard Coupling.....................................23 Fig. 7011 Standard Coupling....................................24-25 Fig. 7000 Lightweight Coupling ......................... 26-27 Fig. 7400 Rigidlite® Coupling ................................28-29 Fig. 7003 Hingelok® Coupling................................ 30-31 Fig. 7010 Reducing Coupling ................................. 32-33 Fig. 7012 Gruvlok Flange ..........................................34-36 Fig. 7013 Gruvlok Flange...........................................37-39 Fig. 7240 Expansion Joint ........................................40-41 branch outlets Fig. 7042 Outlet Coupling ......................................42-43 Fig. 7045 Clamp-T, FPT Branch .............................44-46 Fig. 7046 Clamp-T, Grooved Branch ................. 47-48 Fig. 7047, Fig. 7048 & Fig. 7049 Clamp-T, Cross...49 Fig. 7044 Branch Outlet .................................................50 fittinGs for Grooved-end pipe Technical Data ......................................................................51 Fig. 7050 90˚ Elbow ..........................................................52 Fig. 7051 45˚ Elbow ............................................................52 Fig. 7052 221/2˚ Elbow ......................................................52 Fig. 7052i 221/2˚ Elbow.....................................................52 Fig. 7053 111/4˚ Elbow ........................................................53 Fig. 7050LR 90˚ Long Radius Elbow .........................53 Fig. 7051LR 45˚ Long Radius Elbow ...........................53 Fig. 7063 Tee with Threaded Branch ....................... 54 Fig. 7061 Reducing Tee Standard ............................... 54 Fig. 7064 Reducing Tee with Threaded Branch ..55 Fig. 7060 Tee .........................................................................55 Fig. 7076 Gr x Thd Concentric Reducer................. 56 Fig. 7073 & Fig. 7097 Eccentric Reducer ................ 56 Fig. 7077, Fig. 7078 & Fig. 7079 Swaged Nipple ...57 Fig. 7072 Gr x Gr Concentric Reducer.................... 58 Fig. 7072i Gr x Gr Concentric Reducer .................. 58 Fig. 7069 45˚ Lateral ......................................................... 59 Fig. 7070 45˚ Reducing Lateral ................................... 59 Fig. 7066 Tee Wye .............................................................60 Fig. 7067 Reducing Tee Wye........................................60 Fig. 7071 True Wye ............................................................60 Fig. 7087 Gr x FPT Female Thread Adapter .......... 61 Fig. 7055 Gr x MPT 90˚ Adapter Elbow .................. 61 Fig. 7056 Gr x MPT 45˚ Adapter Elbow .................. 61 Fig. 7050RF Grooved x 150# Flanged (GxF) .......... 62 Fig. 7084 Groove x Class 150 Flange Nipple ....... 62 Fig. 7085 Groove x Class 300 Flange Nipple ...... 62 Fig. 7074 Cap .........................................................................63 Fig. 7075 Bull Plug ...............................................................63 Fig. 7068 Cross .....................................................................63 Fig. 7086 Gr x Hose Nipple ..........................................64 Fig. 7080 Gr x Gr ................................................................64 Fig. 7081 Gr x MPT.............................................................64 Fig. 7082 Gr x Bev ..............................................................64 Fig. 7062 Bullhead Tee Specialty Tee (Gr x Gr x FPT). 65 Fig. 7065 Standpipe Tee (Gr x Gr x FPT) ................ 65 Fig. 7050DR 90˚ Drain Elbow ...................................... 65 Fig. 7450 90˚ Short Pattern Elbow............................66 Fig. 7460 Short Pattern Tee ..........................................66 KNX Model CA – CBV Accessory......................90-94 KNX Model AU – Accessory Union .........90-92, 95 KNX Model UV – Integral Ball Valve Union..90-92, 96 KNX Model SV – Integral Ball Valve Strainer ..90-92, 97 KNX Series Configuration Options..........................98 Model FTV-S & FTV-A Tri-Service Valves ...99-100 Fig. 7260 Tee Strainer ............................................ 101-102 Model 758G Grooved-End "Wye" Strainer .........103 Model 768G Grooved-End "Wye" Strainer ........ 104 Fig. 7250 Suction Diffuser .................................. 105-106 Model GAV-15 Automatic Air Vent ........................107 Model GAV-30 Automatic Air Vent ......................108 ANVILFLEX™ FLEX CONNECTORS FIG. 7050-3D LONG RADIUS ELBOWS Fig. 7050-3D 90˚ Elbow...................................................67 Fig. 7057-3D 60˚ Elbow ...................................................67 Fig. 7051-3D 45˚ Elbow .....................................................67 Fig. 7058-3D 30˚ Elbow ...................................................67 Fig. 7052-3D 221/2˚ Elbow ..............................................67 Fig. 7053-3D 111/4˚ Elbow.................................................67 Fig. AF21-GG Grooved Ends Connector.............. 109 Fig. AF21-GF Gr x Class 150 Flanged Flex Connector ....................................................................110 Fig. AF21-FF Class 150 Flanged x Class 150 Flanged Flex Connector........................................................... 110 Fig. AF21-RFF Class 150 Flanged x Class 150 Flanged Reducing Flex Connector.....................111 Fig. AF21-RGF Gr x Class 150 Flanged Reducing Flex Connector............................................................112 hiGh pressure systems HIGH PRESSURE COUPLINGS FIG. 7050-5D LONG RADIUS ELBOWS Fig. 7004 Coupling .................................................... 114-115 Fig. 7004 Coupling with EG® Gasket ...............116-117 Fig. 7050-5D 90˚ Elbow..................................................68 Fig. 7057-5D 60˚ Elbow ..................................................68 Fig. 7051-5D 45˚ Elbow....................................................68 Fig. 7058-5D 30˚ Elbow ..................................................68 Fig. 7052-5D 221/2˚ Elbow .............................................68 Fig. 7053-5D 111/4˚ Elbow ...............................................68 HIGH PRESSURE FITTINGS Fig. 7050 EG High Pressure 90˚ LR Elbow.............118 Fig. 7051 EG High Pressure 45˚ LR Elbow...............118 Fig. 7060 EG High Pressure Tee ..................................119 Fig. 7662 EG High Pressure Header Tee ..................119 Fig. 7068 EG High Pressure Cross ..............................119 Gruvlok® cts copper system Technical Data .................................................................. 120 Fig. 6400 Rigid Coupling ...............................................121 FIG. 7050-6D LONG RADIUS ELBOWS Fig. 7050-6D 90˚ Elbow .................................................69 Fig. 7057-6D 60˚ Elbow ..................................................69 Fig. 7051-6D 45˚ Elbow ...................................................69 Fig. 7058-6D 30˚ Elbow ..................................................69 Fig. 7052-6D 221/2˚ Elbow .............................................69 Fig. 7053-6D 111/4˚ Elbow ...............................................69 valves & accessories Series 7700 Butterfly Valve....................................70-74 Series 7600 Butterfly Valve...........................................75 Series 8000GR Butterfly Valve ............................76-78 Series 171N & 1715 Brass Ball Valve .....................79-80 Series 7500 Ball Valve ...............................................81-82 Fig. 400G Grooved-End Silent Check Valve ....... 83 Series 7800 Check Valve ........................................84-86 Series GBV-G & GBV-A Balancing Valves .......87-88 Series GBV-S & GBV-T Globe Valves .......................89 KNX Model CU – CBV Union ..............................90-94 CTS COPPER SYSTEM FITTINGS Fig. 6050 90˚ Elbow ...................................................122 Fig. 6051 45˚ Elbow .....................................................122 Fig. 6060 Tee..................................................................122 Fig. 6074 End Caps ......................................................122 Fig. 6061 (Gr x Gr x Gr) Reducing Tee ...............123 Fig. 6064 (Gr x Gr x Cup) Reducing Tee...........123 Fig. 6072 (Gr x Gr) Concentric Reducer.......... 124 Fig. 6075 (Gr x Cup) Reducing Adapter .......... 124 Fig. 6084 Flange Adapter ....................................... 124 Series 6700 CTS Copper Butterfly Valve..125-126 Gruvlok di-lok® nipple & di-electric pipe connection Fig. 7091 - CTS Groove by IPS Groove..............127 4 www.anvilintl.com GL-7.12 IntroductIon Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories table of contents Gruvlok plain end fittinGs Fig. 7005 Roughneck® Coupling.......................... 128 PLAIN-END FITTINGS Technical Data ............................................................. 129 Fig. 7050P 90˚ Elbow ................................................ 129 Fig. 7051P 45˚ Elbow .................................................. 129 Fig. 7060P Tee............................................................... 129 Fig. 7068P Cross........................................................... 130 Fig. 7061P Reducing Tee .......................................... 130 Fig. 7069P 45˚ Lateral................................................ 130 Fig. 7071P 90˚ True Wye.......................................... 130 Fig. 7050LRP 90˚ LR Elbow .................................... 130 Fig. 7051LRP 45˚ LR Elbow ........................................131 Fig. 7084P & Fig. 7085P (Plain-End x Class 150 or 300) Flange Nipple .........................................131 Fig. 7075P Bull Plug ......................................................131 Fig. 7080P Plain x Grooved.....................................132 Fig. 7081P Plain x Thread ..........................................132 Fig. 7082P Plain x Bevel.............................................132 Fig. 7077P Swaged Nipple .......................................132 hdpe couplinGs Fig. 7305 HDPE Coupling .................................133-134 Fig. 7307 HDPE Transition Coupling ......... 135-136 Fig. 7312 HDPE Flange Adapter .....................137-138 sock-it® pipinG method fittinGs Technical Data ..............................................................139 Fig. 7100 90˚ Elbow ....................................................139 Fig. 7101 90˚ Reducing Elbow ...............................140 Fig. 7103 Straight Tee ................................................140 Fig. 7107 Coupling ......................................................140 Fig. 7105 Reducing Outlet Tee .............................. 141 Fig. 7106 Reducing Tee.............................................. 141 stainless steel method Fig. 7400SS Rigidlite® Coupling ............................142 Fig. 7074SS Stainless Steel Caps ......................... 146 Fig. 7061SS Stainless Steel Reducing Tee............147 Fig. 7072SS Stainless Steel Concentric Reducer..147 Fig. 7073SS Stainless Steel Eccentric Reducer..147 Fig. 7084SS Stainless Steel Flange Adapter Type 304 (Groove x Class 150) .....................147 roll Groovers Model 1007 & 3007 Roll Groovers .......... 148-149 Model 3006 Roll Groover ..............................150-151 couplinG installation & assembly Specified Bolt Torque ...............................................152 Fig. 7401 Rigidlok® Coupling ...................................153 Fig. 7001 Standard Coupling ..................................154 Fig. 7001-2 & Fig. 7401-2 Two Piece Large Dia. Couplings....................155 Fig. 7011 Standard Coupling................................... 156 Fig. 7000 Lightweight Coupling ..........................157 Fig. 7400 Rigidlite® Coupling ................................ 158 Fig. 6400 Rigid Coupling ........................................ 159 Fig. 7003 Hingelok® Coupling...............................160 Fig. 7010 Reducing Coupling ................................. 161 Fig. 7012 Gruvlok Flange (2"-12") ..................162-163 Fig. 7012 Gruvlok Flange (14"-24")........................ 164 Fig. 7042 Outlet Coupling ..................................... 165 Fig. 7045 & Fig. 7046 Clamp-T® Branch Outlets......................................................166 Fig. 7044 Branch Outlet ...........................................167 Fig. 7005 Roughneck® Coupling..........................168 Fig. 7004 High Pressure Coupling ...................... 169 Fig. 7004 Coupling with End Guard Gasket . 170 Fig. 7305 HDPE Coupling ......................................... 171 Fig. 7307 HDPE Transition Coupling ..................172 Fig. 7312 HDPE Flange Adapter .............................173 Gruvlok Sock-It® Fitting ...........................................174 Model FTV Tri-Service Valve ....................... 175-178 Series GBV-S & GBV-T Circuit Balancing Valves............................................179-181 AnvilFlex™ Flex Connectors ................................... 182 special coatinGs Anvil Special Coatings ..............................................183 desiGn services Basic & Extended Services..................................... 184 Drawing Examples..............................................185-187 technical data Table of Contents ......................................................188 Gruvlok® Lubricants ..............................................189 Specified Bolt Torque...........................................190 Design Factors..........................................................190 ADAPTER NIPPLES Gruvlok Flow Control Components ..............191 Gruvlok Gasket Styles.......................................... 192 Gasket Grade Index............................................... 193 Gruvlok Gasket Recommendations ......194-195 Movement-Applications.............................196-197 Coupling Working Pressure Rating on Light Wall Roll Grooved Steel Pipe ........198 Coupling Working Pressure Rating on Roll Grooved ISO Steel Pipe ......................199 Coupling & Flange Working Pressure Rating on 304 & 316 Stainless Steel Roll Grooved Pipe..200 Pipe Support ....................................................201-203 Coupling Flexibility .................................... 204-205 Drafting Symbols for Gruvlok Piping Systems...206 Pipe Preparation ........................................... 207-208 Roll Groove Specifications ...............................209 Cut Groove Specifications.................................210 Cut Groove End Guard® Specification .......... 211 Roll Groove End Guard® Specification.......... 211 Gruvlok CTS Copper System Roll Groove Specification .............................. 212 Fig. 7240 Order Form .............................................213 master format 3 part specification Section 15050 .......................................................214-219 Section 15300 ......................................................219-223 Section 15400 .....................................................223-228 Section 15500 ..................................................... 228-232 Section 15600......................................................232-238 pictorial index Pipe Fittings Products ....................................239-248 Pipe Hanger Products.....................................249-253 Anvil-Strut™ Products .................................... 254-260 index Numeric Index ............................................................. 261 terms & conditions Product Terms & Conditions................................262 cross reference Gruvlok Product Cross Reference.....................263 GRUVLOK STAINLESS STEEL FITTINGS TYPE 304 FITTINGS Technical Data ..............................................................143 Fig. A7050-SS04 90˚ Stainless Steel Elbow .. 144 Fig. A7051-SS04 45˚ Stainless Steel Elbow .... 144 Fig. A7060-SS04 Stainless Steel Tee ................ 144 Fig. A7074-SS04 Stainless Steel Caps .............. 144 Fig. A7061-SS04 Stainless Steel Reducing Tee .145 Fig. A7072-SS04 Stainless Steel Concentric Reducer .145 TYPE 316 FITTINGS Fig. 7050SS 90˚ Stainless Steel Elbow............. 146 Fig. 7051SS 45˚ Stainless Steel Elbow............... 146 Fig. 7060SS Stainless Steel Tee ........................... 146 www.anvilintl.com GL-7.12 5 8" Fig.24" Fig.24" Fig.14" Size Range: 16" Size Range: 18" .30" Fig. 7000 4'' FIG. 7401 Pages 18-19 Rigidlok® Coupling Fig. 7047. 7401-2 Page 20 Rigidlok® Coupling Size Range: 14" . 7048 & Fig.8" Size Range: 1" . 7011 Pages 24-25 Standard Coupling Size 30" Fig. 7000 4'' FIG.12" NIPPLE COUPLING END ADAPTER G RUVLOK G RUVLOK G RUVLOK G RUVLOK Size Range: 2" . FPT Branch Size Range: 3" x 11/4" thru 8" x 4" Page 49 (U-Bolt) Size Range: 21/2" x 1/2" thru 4" x 1" Branch Outlet Size Range: 11/4" x 1/2" thru 21/2" x 1" Fig. Grooved Branch Size Range: 3" x 11/4" thru 8" x 4" (U-Bolt) Size Range: 21/2" x 11/4" thru 21/2" x 11/2" Fig.4" and 5" .6" Fig. 7001 Pages 21-22 Standard Coupling Fig. 7042G Grooved Outlet Clamp-T. 7046 Pages 47-48 Fig. 7013 Pages 37-39 Gruvlok Flanges (#300 Flange) Size Range: 2" .anvilintl. 7001-2 Page 23 Standard Coupling Size Range: 14" .12 G RUVLOK 4'' FIG. 7042 Pages 42-43 Outlet Coupling Size Range: 11/2" . 7000 Pages 26-27 Lightweight Coupling Size Range: 1" . 7000 . 7042F Female IPS Outlet Fig. 7049 Clamp-T Cross Size Range: 2" x 1/2" thru 8" x 4" Clamp-T. 7012 Pages 34-36 Gruvlok Flanges Fig. 7400 Pages 28-29 300 PSI Rigidlite® Coupling Size Range: 1" . 7010 Pages 32-33 Reducing Coupling Size Range: 2" x 11/2" thru 8"x 6" Fig. 7240 Pages 40-41 Expansion Joints Size Range: 2" . 7044 Page 50 Fig. 7047 Thread x Thread Fig.com GL-7.8" Size Range: 11/2" . Fig.24" branch outlets Fig.24" Fig. 7048 Groove x Groove Fig. 7049 Groove x Thread 6 www. 7000 4'' FIG.IntroductIon Gruvlok® pictorial parts index couplinGs Fig.14" Size Range: 16" .12" Fig. 7000 4'' FIG. 7003 Pages 30-31 Hingelok® Coupling Size Range: 1" .24" Size Range: 28" . 7042M Male IPS Outlet Fig. 7045 Pages 44-46 Fig.12" Size Range: 14" . 7051LR Page 53 45˚ Long Radius Elbow Size Range: 1" .12" Fig. 7072 Page 58 Gr x Gr Concentric Reducer Size Range: 11/4" x 1" thru 24" x 20" Fig.6" Fig. 7064 Page 55 Reducing Tee with Threaded Branch Size Range: 2" x 2" x 3/4" thru 24" x 24" x 12" Fig. 7075 Page 63 Bull Plug Size Range: 2" . 7061 Page 54 Reducing Tee Standard Size Range: 11/4" x 11/4" x 1" thru 24" x 24" x 20" Fig. 7050RF Page 62 Reducing Base Support Elbow Groove x 150# Flange (GxF) Size Range: 6" x 4" thru 12" x 10" Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Grooved fittinGs Fig. 7050 Page 52 90˚ Elbow Size Range: 1" .24" Fig.24" Fig. 7077. 7087 Page 61 Female Thread Adapter Size Range: 1" . 7073 Groove x Groove Fig. 7069 Page 59 45˚ Reducing Lateral Size Range: 3" x 3" x 2" thru 24" x 24" x 20" Fig.IntroductIon Fig. 7073 & Fig. 7060 Page 55 Tee Size Range: 1" . 7078 & 7079 Swaged Nipples Size Range: 2" x 1" thru 6" x 5" Page 57 Fig.12" Fig. 7056 Page 61 45˚ Adapter Elbow Size Range: 1" .anvilintl.24" Fig.24" Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.12 7 .com GL-7. 7067 Page 60 Reducing Tee Wye Size Range: 4" x 3" x 3" thru 8" x 6" x 8" Fig. 7071 Page 60 True Wye Size Range: 1" . 7066 Page 60 Tee Wye Size Range: 2" x 2" x 2" thru 12" x 12" x 12" Fig.24" Fig. 7050LR Page 53 90˚ Long Radius Elbow Size Range: 1" .24" Fig. 7053 Page 53 111/4˚ Elbow Size Range: 1" . 7084 Page 62 Groove x Class 150 Flange Nipple Size Range: 1" .24" Fig. 7065 Page 65 Standpipe Tee (Gr x Gr x FPT) Size Range: 4" x 4" x 21/2" thru 6" x 6" x 21/2" Fig.24" Fig. 7051 Page 52 45˚ Elbow Size Range: 1" . 7052i Page 52 221/2˚ Elbow Size Range: 1" . 7055 Page 61 90˚ Adapter Elbow Size Range: 1" .6" Fig. 7062 Page 65 Bullhead Tee Specialty Tees (Gr x Gr x FPT) Size Range: 5" x 5" x 8" thru 6" x 6" x 8" Fig.24" Fig. 7086 Page 64 Groove x Hose Nipple Size Range: 1" . 7085 Page 62 Groove x Class 300 Flange Nipple Size Range: 3" .12" Fig. 7097 Page 56 Eccentric Reducers Size Range: 11/4" x 1" thru 24" x 20" Fig. 7078 Groove x Thread Fig. 7070 Fig.8" Fig.4" Fig. 7097 Groove x Thread Fig. 7063 Page 54 Tee with Threaded Branch Size Range: 1" . 7050DR Page 65 90˚ Drain Elbow Size Range: 11/4" .24" Fig. 7076 Page 56 Gr x Thd Concentric Reducer Size Range: 11/2" x 1" thru 6" x 5" Fig.24" Fig.12" www. 7074 Page 63 Cap Size Range: 11/4" . 7079 Groove x Bevel Page 59 45˚ Lateral Size Range: 1" .24" Fig.6" Fig. 7072i Page 58 Gr x Gr Concentric Reducer Size Range: 11/4" x 1" thru 10" x 8" Fig. 7077 Groove x Groove Fig. 7052 Page 52 221/2˚ Elbow Size Range: 1" . 7068 Page 63 Cross Size Range: 1" . 7081 Groove x MPT Fig.anvilintl. 7080 Groove x Groove Fig. 7053-6D 111/4˚ Elbow valves & accessories Series 7700 Pages 70-74 Butterfly Valve Size Range: 2" . 7051-5D 45˚ Elbow Fig.8" Fig.2" 8 www.6" AN-7722-3 Series 7700 Butterfly Valve with Gear Operator AN-7721-3 Series 7700 Butterfly Valve with 10 Position Lever Lock Fig. GroovedEnd Angle Size Range: 21/2" . 400G Page 83 Grooved-End Silent Check Valve Size Range: 2" . 7052-6D 221/2˚ Elbow Fig. 7081 & Fig. 7057-6D 60˚ Elbow Fig. 7053-5D 111/4˚ Elbow Fig.24" Fig.24" Series 171 & 1715 Pages 79-80 Brass Ball Valve 171N – Size Range: 1/4" . 7053-3D 111/4˚ Elbow Fig. Threaded (GBV-T) Size Range: 1/2" . 7057-5D 60˚ Elbow Fig.12 .IntroductIon Grooved fittinGs Fig. 7050-6D Page 69 Long Radius Elbows Size Range: 2" .24" Fig. 7450 Page 66 90˚ Short Pattern Elbow Size Range: 2" .6" Series 8000GR Pages 76-78 Butterfly Valve Size Range: 14" . 7058-6D 30˚ Elbow Fig.4" 1715 – Size Range: 1/2" . 7050-5D 90˚ Elbow Fig. 7050-5D Page 68 Long Radius Elbows Size Range: 2" . 7050-3D 90˚ Elbow Fig. 7058-5D 30˚ Elbow Fig.4" Series 7500 Pages 81-82 Ball Valve Size Range: 2" . GroovedEnd Straight Size Range: 21/2" .10" Series 7800 Pages 84-86 Check Valve for use in Grooved-End Piping Systems Size Range: 2" . 7080. 7050-3D Page 67 Long Radius Elbows Size Range: 2" .12" Series 7600 Page 75 Butterfly Valve Size Range: 2" . 7057-3D 60˚ Elbow Fig. 7082 Page 64 Nipples Size Range: 1" . 7058-3D 30˚ Elbow Fig. 7460 Page 66 Short Pattern Tee Size Range: 2" . Solder (GBV-S) Cast Bronze.com GL-7. 7052-5D 221/2˚ Elbow Fig.12" GBV-G Page 87 Balancing Valve Ductile Iron. 7082 Groove x Bevel Fig. 7051-6D 45˚ Elbow Fig. Fig. 7051-3D 45˚ Elbow Fig.24" Fig. 7050-6D 90˚ Elbow Fig.8" Fig. 7052-3D 221/2˚ Elbow Fig.12" GBV-A Page 88 Balancing Valve Ductile Iron.12" GBV-S & GBV-T Page 89 Globe Valves Cast Bronze.12" Fig. 7068 EG Page 119 High Pressure Cross Size Range: 2" .12" Model 768G Page 104 Grooved-End "Wye" Strainer Size Range: 2" . 7060 EG Page 119 High Pressure Tee Size Range: 2" .IntroductIon KNX Model CU Pages 90-94 CBV Union Size Range: 1/2" . AF21-RFF Reducing Class 150 Flanged x Class 150 Flanged Fig. 96 Integral Ball Valve Union Size Range: 1/2" .3/4" AnvilFlex™ AF21 Series Flex Connectors Size Range: 2" .6" Fig.12" Fig. AF21-FF Class 150 Flanged x Class 150 Flanged Fig.1" Model GAV-30 Page 108 Automatic Air Vent for Ultimate Performance Size Range: 1/2" . AF21-GF Grooved x Class 150 Flanged Fig. 7004 with EG® Gasket Pages 116-117 Coupling with EG Gasket Size Range: 2" .12" FTV-A Pages 99-100 Tri-Service Valve (Angle Body) Size Range: 21/2" .2" KNX Model SV Pages 90-92. 97 Integral Ball Valve Strainer Size Range: 1/2" . 7250 Model GAV-15 Page 107 Automatic Air Vent for Ultimate Performance Size Range: 1/2" . 7051 EG Page 118 High Pressure 45˚ LR Elbow Size Range: 2" . 95 Accessory Union Size Range: 1/2" .12" Fig.12" Fig. 7004 Pages 114-115 Coupling Size Range: 2" . AF21-RGF Reducing Grooved x Class 150 Flanged hiGh pressure systems Fig.anvilintl.6" Fig.18" Model 758G Page 103 Grooved-End "Wye" Strainer Size Range: 2" .2" KNX Model AU Pages 90-92.com GL-7.6" Fig. 7662 EG Page 119 High Pressure Header Tee Size: 2" Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories valves & accessories . 7260 Pages 101-102 Gruvlok Tee Strainer Size Range: 2" .2" KNX Model UV Pages 90-92. AF21-GG Grooved Ends Fig.12" Pages 109-112 Fig.12 9 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.12" Fig. 7050 EG Page 118 High Pressure 90˚ LR Elbow Size Range: 2" .2" KNX Model CA Pages 90-94 CBV Accessory Size Range: 1/2" .12" www. 7250 Pages 105-106 Suction Diffuser Size Range: 21/2" x 21/2" thru 16" x 14" FIG.2" FTV-S Pages 99-100 Tri-Service Valve (Straight) Size Range: 21/2" . Fig.8" Fig.8" Fig.IntroductIon cts copper system Fig.8" Fig. 6051 Page 122 45˚ Elbow Size Range: 2" . 7085P Flange Nipples Plain-End x Class 150 Size Range: 2" . 6064 Page 123 Reducing Tee (Gr x Gr x Cup) Size Range: 2" x 2" x 3/4" thru 4" x 4" x 11/2" Fig.8" Fig.8" Fig.6" Fig. 6072 Page 124 Concentric Reducer (Gr x Gr) Size Range: 21/2"x 2" thru 8" x 6" Fig. 7061P Page 130 Reducing Tee Size Range: 3" x 3" x 2" thru 12" x 12" x 10" Fig. 7051P & Fig. 7051P 45˚ Elbow Page 132 Fig.6" Series 6700 CTS Copper Butterfly Valve Size Range: 21/2" . 7305 Pages 133-134 HDPE Coupling Size Range: 2" . 7080P. 7005 Page 128 Roughneck® Coupling Size Range: 2" . 7060P Gruvlok Plain-End Fittings Size Range: 2" .8" Plain-End x Class 300 Size Range: 2" . 7050LRP Page 130 90˚ LR Elbow Size Range: 2" . 6050 Page 122 90˚ Elbow Size Range: 2" .16" Fig.8" Fig. 7080P Plain x Groove Fig. 6084 Page 124 Flange Adapter Size Range: 2" . 7307 Pages 135-136 HDPE Transition Coupling Size Range: 2" .8" Fig. 6060 Page 122 Tee Size Range: 2" . 7071P Page 130 90˚ True Wye Size Range: 2" .8" Page 129 Fig. 7081P Plain x Thread Fig.anvilintl. 7312 Pages 137-138 HDPE Flange Adapter Size Range: 4" . 7050P 90˚ Elbow Fig.8" Fig. 7068P Page 130 Cross Size Range: 2" . 7091 Page 127 Gruvlok DI-LOK® Nipple Di-Electric Pipe Connection CTS Groove x IPS Groove Size Range: 3/4" . 7050P. 7069P Page 130 45˚ Lateral Size Range: 2" . 7060P Tee hdpe couplinGs Fig. 7084P & Fig.8" Fig. 7075P Page 131 Bull Plug Size Range: 2" .8" Fig.8" Fig.12" Fig.com GL-7.8" Page 131 10 www. 7082P Adapter Nipples Size Range: 2" .6" Pages 125-126 di-lok® nipple Fig. 7077P Page 132 Swaged Nipple Size Range: 21/2" x 2" thru 8" x 6" Fig. 6075 Page 124 Reducing Adapter (Gr x Cup) Size Range: 2" x 1" thru 4" x 2" Fig.12" Fig. 7082P Plain x Bevel Fig. 7081P & Fig.12 . Fig. 7051LRP Page 131 45˚ LR Elbow Size Range: 2" .8" Fig. 6400 Page 121 Rigid Coupling Size Range: 2" . 6061 Page 123 Reducing Tee (Gr x Gr x Gr) Size Range: 21/2" x 21/2" x 2" thru 6" x 6" x 5" Fig.6" plain-end fittinGs Fig. 6074 Page 122 End Cap Size Range: 2" . 12" Page 144 Stainless Steel Tee Size Range: 11/4" . 7060-SS04 Page 144 Stainless Steel Cap Size Range: 11/4" . 7084SS Page 147 Stainless Steel Flange Adapter Size Range: 2" . 7050-SS04 Fig.IntroductIon Fig.12" Fig. 7061-SS04 Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories sock-it® method stainless steel method ss type 304 fittinGs Fig. 7072-SS04 Page 145 Stainless Steel Reducing Tee Size Range: 11/2" x 11/4" thru 12" x 10" Page 145 Stainless Steel Concentric Reducer Size Range: 11/2" x 11/4" thru 12" x 10" ss type 316 fittinGs Fig.12" Fig. 7107 Page 140 Coupling (Sock-It x Sock-It) Size Range: 1" .2" Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.12" Fig. 7103 Page 140 Straight Tee (Sock-It x Sock-It x Sock-It) Size Range: 1" . 7051-SS04 Fig.anvilintl. 7072SS Page 147 Stainless Steel Concentric Reducer Size Range: 11/2" x 1" thru 8" x 6" Fig. 7061SS Page 147 Stainless Steel Reducing Tee Size Range: 11/2" x 11/2" x 3/4" thru 8" x 8" x 6" Fig. 7105 Page 141 Reducing Outlet Tee (Sock-It x Sock-It x NPT) Size Range: 1" x 1" x 1/2" thru 21/2 x 21/2 x 1" Fig.2" Fig.2" Fig.12" Fig.12" Fig. 7060SS Page 146 Stainless Steel Tee Size Range: 11/4" . 7106 Page 141 Reducing Tee (Sock-It x Sock-It x NPT) Size Range: 11/4" x 1" x 1/2" thru 2 x 11/2 x 1" Fig.8" Fig. 7050SS Page 146 90˚ Stainless Steel Elbow Size Range: 11/4" .12" www. 7101 Page 140 90˚ Reducing Elbow (Sock-It x NPT) Size Range: 1" x 1/2" thru 11/2" x 1" Fig. 7400SS Page 142 Rigidlite® Coupling Size Range: 11/4" . 7100 Page 139 90˚ Elbow (Sock-It x Sock-It) Size Range: 1" .12" Page 144 45˚ Stainless Steel Elbow Size Range: 11/4" .12" Page 144 90˚ Stainless Steel Elbow Size Range: 11/4" . 7073SS Page 147 Stainless Steel Eccentric Reducer Size Range: 11/2" x 1" thru 8" x 6" Fig. 7074-SS04 Fig.12 11 . 7074SS Page 146 Stainless Steel Cap Size Range: 11/4" .com GL-7. 7051SS Page 146 45˚ Stainless Steel Elbow Size Range: 11/4" . Patents 5450738.16" Model 3006 Pages 150-151 Roll Groover Groover Capability: 2" .11 . Model 1007 Pages 148-149 Roll Groover Groover Capability: 2" . 5570603.12" 12 www.anvilintl.IntroductIon roll Groovers Gruvlok roll grooving technology is protected by U.S. 5778715 and others pending.com GL-6.16" Model 3007 Pages 148-149 Roll Groover Groover Capability: 2" . Grooved MIL-I-45208 Inspection Procedure National Aeronautics and Space Administration: 15000 Series uSGBc VA VdS uL uLc nY-BSA New York Board of Standards and Appeals nYc tVA New York City Tennessee Valley Authority: Fire protection. Underwriter’s Laboratories of Canada Bureau of Marine Inspection: Salt and fresh water.9. butterfly valves. visit our website at www. ASHrAE American Society of Heating. www.3. pipe preparation tools and various accessories. MIL-P-11087A(CE) Steel Pipe. MIL-C-10387 Couplings. Plumbing. 5L. Chemical Plant and Petroleum Refinery Piping. B 31. General Services Administration: 15000 Series International Association of Plumbing & Mechanical Officials Loss Prevention Council Materials & Equipment Acceptance Military Specifications: MILP-10388 Fittings. ISO 9001:2008 InduStrY & GoVErnMEnt StAndArdS & APProVALS AnSI API American National Standards Institute American Petroleum Institute: API Std.5.5 FAA FHA FM GSA IAPMo LPc MEA MIL Federal Aviation Administration: HVAC. Sect. of Bridges: Drain lines and bridge crossings Canadian Coast Guard U. Fire Protection Federal Housing Administration Factory Mutual Engineering Corp. VdS For Listings/Approval Details and Limitations.V. Slurry Pipelines. Gruvlok is part of our overall commitment to provide today’s piping industry with tomorrow’s products. (1991) AStM AWWA BV cdF coE cSA dnV nASA nAVFAc Naval Facilities Engineering Command: NFGS 15000 Series nFPA nIH nSF National Fire Protection Association National Institute of Health (Dept. Building Services Piping. Coast Guard –Approves each vessel individually United States Green Building Council Veterans Affairs : 15000 Series Verband der Sachversicherer e.11 American Society of Testing and Materials: F 1476.com or contact an Anvil® Sales Representative. oil transfer Bureau of Public Roads. F 1387 American Water Works Association: C 606 Bureau Veritas California State Fire Marshal Corps of Engineers: CEGS 15000 Canadian Standards Association: B 242 Det Norske Veritas Hong Kong Fire Services Board New Zealand Insurance Council New Zealand Building Act. B 31. of Health): 15000 Series NSF International note: Please refer to product specific pages for exact listings and approvals related to a specific size for a specific product. B 31. B 31.S.anvilintl.12 13 . Inc. pump protection components.com GL-7. 7. Refrigerating and Air Conditioning Engineers ASME American Society of Mechanical Engineers: Power Piping. B 31. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories products for Grooved pipinG system The Gruvlok® System has been manufactured since the late 1960’s. plain-end product. check valves. Div.anvilintl. Refrigeration Piping.1.AGEncY IntroductIon APProVALS Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. The Gruvlok product line has grown from standard couplings and fittings to today’s extensive range of grooved product. storm drains Underwriter’s Laboratories. The groove diameters must be dimensionally accurate to obtain the maximum benefit of the Gruvlok Coupling. GrooVEd PIPE EndS (d) The ends of the pipe must have a groove in them which may be either cut grooved or roll grooved. thus restraining the pipe ends from separation due to the application of internal pressure. GASKEt (B) The unique single piece “C” style design of the gasket has been engineered to provide a pressure responsive. leak-tight seal in both pressure and vacuum applications without the aid of external forces. Rigid couplings grip the pipe and lock the joint into position. The oval neck design prevents turning of the bolt while tightening the hex nut with a single wrench.anvilintl. providing a self-restraining. producing leak paths. However. Gasket Reaction to Pressure Gasket Reaction to Vacuum 14 www. The “lips” of the gasket are molded so that upon installation onto the pipe ends they provide compression against the pipe surface to establish the leak-tight seal. non-pressure-responsive seals tend to “lift off” the pipe. The grooved pipe ends engage the coupling keys. for couplings used in corrosive environments. The gasket cavity functions as a “pressure reservoir”. The housing encircles and retains the gasket against the application of internal system pressure or vacuum.com GL-6. However. The housing key sections fit into and engage the pipe-end grooves around the entire pipe circumference. All housings are coated with paint for general service applications. Pressure within the pipe system is applied to the internal surfaces of the gasket which increases the sealing force and enhances the leak-tight seal. A B D C BoLtS And nutS (c) Heat treated oval neck track head bolts serve to connect and secure the housing segments together. The bolt size and corresponding wrench (or socket) size for the hex nuts are shown in the chart below. In vacuum systems.IntroductIon Gruvlok® – the enGineered couplinG HouSInG (A) FLEXIBLE or rIGId The Gruvlok Coupling housing is designed to self-center around the pipe. hot-dip galvanizing. the Gruvlok gasket reacts to the negative pressure (higher outside atmospheric pressure) as to improve the sealing capability of the gasket. thus. and stainless steel are available. Flexible Couplings provide designed-in clearances between the housing key sections and the pipe grooves to permit both angular and longitudinal movement of the pipe.11 . mechanical joint capable of resisting the separation of the pipe ends due to the application of system pressure. The paint serves to provide protection against normal atmospheric corrosion. thus permitting deflection in any direction. The need for an expansion joint is minimized or eliminated. expansion joints.anvilintl. The design factors presented in the Gruvlok technical data section should always be referenced to when designing any grooved piping system to obtain the maximum benefit of the Gruvlok piping method. www.IntroductIon Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. minimizes noise & vibration The resilient elastomeric gasket and pre-designed gap of the Gruvlok coupling help isolate and absorb noise and vibration. will provide pitch for drainage piping systems and facilitate laying pipe on uneven terrain. this minimizes vibration transmission. etc. stress-free system Flexibility designed in the Gruvlok coupling absorbs and eliminates stress from settlement of buried pipe or those induced by seismic tremors. self restrained joint The couplings engage the pipe around the entire circumference and restrain the pipe ends from separation due to pressure and other forces. assembly and performance. accommodates misaliGnment and joint deflection The flexibility designed into the Gruvlok coupling will accommodate misalignments caused by imprecise location of pipe opening through walls and floors. the contractor. The Gruvlok piping method offers many mechanical design features which benefit the design engineer.11 15 . Gruvlok couplings for grooved-end pipe are designed to provide a selfcentering joint which accommodates the application of pressure. END LOAD END LOAD union at every joint Gruvlok couplings can be disassembled easily permitting maintenance and servicing of the piping system.com GL-6. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories the Gruvlok® pipinG method Gruvlok couplings and grooved-end fittings are widely used for joining pipe in a wide variety of piping systems. and the end user. Utilization of the functional characteristics of the Gruvlok coupling will aid in pipe system design and must be considered for proper installation. GruVLoK FEAturES riGidity or flexibility Couplings are available where rigid connections are required. while limiting the burdensome need for special supports. Couplings with flexible design allow for pipe expansion and contractions with temperature changes. vacuum and other external forces. It will facilitate periodic rotation of pipe to distribute internal wear from slurries or other abrasive media. up to the maximum coupling rated working pressure. diluted acids. Bolts and nuts are provided zinc electroplated as standard.com GL-7. Grade 65-45-12 or Malleable Iron conforming to ASTM A 47. Air with oil vapors and vegetable and mineral oils. diluted acids. or J995 Grade 2. halogenated hydrocarbons and lubricants Grade “L” Silicone (red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 GrAdE “E” EPdM (Green color code) nSF-61 certified -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. See technical data section for design factors. coAtInGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative.24") (25mm .anvilintl. NOT FOR USE IN PETROLEUM APPLICATIONS. alkalies solutions. The variety of coupling designs provide a universal means for the connection of pipe. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. GrAdE “EP” EPdM (Green/red color code) nSF-61 certified -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. 16 www.600mm) LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) WorKInG PrESSurE. hydraulic fluids. NOT FOR USE IN HOT WATER OR HOT AIR Grade “o” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids. Grade “t” nitrile (orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications.12 . MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. NOT FOR USE IN PETROLEUM APPLICATIONS. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. oil-free air and many chemical services. fittings and pipe system components. Contact an Anvil Representative for more information.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B.IntroductIon Gruvlok® couplinGs for Grooved-end pipe Gruvlok couplings for grooved-end pipe are available in nominal pipe sizes 1" thru 30" and metric sizes. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. Hex nuts are zinc electroplated followed by a yellow chromate dip. End LoAd. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. petroleum oils. oil-free air and many other chemical services. The wide assortment of Gruvlok couplings and gaskets permit selection of the most suitable combination for a specific application. Grade 32510. HouSInG: Ductile Iron conforming to ASTM A 536. PIPE End SEPArAtIon & dEFLEctIon FroM cEntEr LInE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. alkalies solutions.8. hot air and some high temperature chemical services GASKEt tYPE: Standard C Style Flush Gap (1" . thus providing the most versatile and economical pipe system installation. com GL-7. For Performance Data on other than standard wall pipe./mm Approx. to which a joint can be subjected./mm Coupling Bolts Z Qty. 3 Maximum line pressure. 2 Nominal Outside Diameter of Pipe.D./mm 1 2 3 4 5 6 7 8 9 10 1 Gruvlok Couplings are identified by either the nominal ANSI pipe size in inches or pipe O./mm Max./kN Range of Pipe End Separation In. Size In. 7 “X”. notE: For one time field test only the maximum joint working pressure may be increased to 1. Max. including surge./kg In. Max. see page 190 for details. refer to Technical data section. Ft. www. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories couplinG data chart notes couPLInG dAtA cHArt notES Nominal Size In. Lbs. Working pressure ratings are based on standard wall steel pipe with standard cut or roll grooves in accordance with Gruvlok specifications. Double values shown when using cut groove pipe. 8 The quantity of bolts per coupling. 6 Maximum allowable angular deflection values from centerline when using standard roll grooved pipe. Wt./mm Deflection from C L Coupling Dimensions X In./DN(mm) O. and nuts.12 17 .D. Double values shown when using cut groove pipe. End Pressure Load PSI/bar Lbs. cut or roll grooves in accordance with Gruvlok specifications. bolts.anvilintl./ft-mm/m Y In. in millimeters (see column 2). 10 Approximate weight for a fully assembled coupling with gasket. Ea.-Lbs/N-m Per Coupling Degrees(˚)-Minutes(') of Pipe In. see page 190 for details. In.IntroductIon Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 4 Maximum end load from all interior and/or exterior forces to which the joint can be subjected are based on standard wall steel pipe with standard 5 Range of pipe end separation for roll grooved pipe. 9 Nuts must be tightened alternating and evenly to the specified bolt torque.5 times the figure shown. Work./mm Specified Torque Min. See individual product installation instructions for additional important information. “Y”. and “Z” are external dimensions for reference purposes only. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids. Rigidity is attained simply. GASKEt tYPE: C Style (Standard 1" . Grade “L” Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry. petroleum oils.com GL-7. 7401 Rigidlok® Coupling The Fig. hydraulic fluids. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. Contact an Anvil Representative for more information. hot air and some high temperature chemical services. halogenated hydrocarbons and lubricants. oil-free air and many other chemical services. The Rigidlok Coupling maintains a rigid connection with For Listings/Approval Details and Limitations. Bolts and nuts are provided zinc electroplated as standard.anvilintl. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. visit our website at www.couPLInGS For GrooVEd-End PIPE fiG. Hex nuts are zinc electroplated followed by a yellow chromate dip. support and hanging in conformance with applicable ANSI B31. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. The Fig. or J995 Grade 2. 7401 Rigidlok coupling utilizes a technologically advanced housing design that conforms to and grips the pipe. remove only one nut and swing the housing over the gasket and into the grooves. HouSInG: Ductile Iron conforming to ASTM A 536.1 Power Piping Code.12") LuBrIcAtIon: Standard Gruvlok XtremeTM (Do Not use with Grade “L”) www. With the Fig. Available 1" . zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. 7401 there emerges a new generation of rigid couplings. 7401 Rigidlok Coupling from Gruvlok provides a rigid pipe connection.com or contact an Anvil® Sales Representative. air with oil vapors and vegetable and mineral oils. Precisely sized and oriented tines in the housing key section firmly grip the pipe. Contact an Anvil Representative for availability. oil-free air and many other chemical services. 7401 Rigidlok Coupling allows for working pressure ratings to 750 psi (51. as well as with grooved-end fittings and valves. alkalies solutions.8. ANSI B31. NOT FOR USE IN PETROLEUM APPLICATIONS. diluted acids. NOT FOR USE IN PETROLEUM APPLICATIONS. NSF-61 Certified for cold and hot water applications up through 12". diluted acids. Grade 65-45-12 coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. The exclusive Guidelok® feature automatically separates the grooved pipe ends and guides the coupling into position as the bolts are tightened. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. The Fig. rigid pipe joint connection.12") Flush Gap (Standard 14" .000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. alkalies solutions.anvilintl.12 18 .9 Building Service Pipe Code as well as NFPA 13 sprinkler systems. This coupling is an ideal connector for service and applications that require a rigid connection.24". 7401 Rigidlok Coupling is designed for use with roll grooved or cut grooved standard weight and roll grooved lightweight pipe. Coupling installation is fast and easy. it is designed in.7 bar) when used on standard wall roll or cut grooved pipe. The Fig. The combination of these designed in features produce a secure. 38 181⁄8 460 221⁄4 565 3 76 180 245 220 300 42.375 60. * Available in ANSI or metric bolt sizes only as indicated.7 750 51.4 20 500 20.3 3. 4./DN(mm) O.819 0-3⁄32 0-2.4 1.3 51.D.24" FIGurE 7401 rIGIdLoK couPLInG Nominal Size In.319 268. www.00 0-2.7 750 11.14" SIzE 16" SIzES 18" .625 168. Wt.9 0-3⁄32 0-2.38 M12 x 76 5 ⁄8 x 31⁄2 139.0 2.70 25.38 201⁄2 521 243⁄8 619 31⁄8 79 200 270 250 340 51.000 457.900 48.10 0-0.7 110.3 40.38 161⁄4 413 193⁄4 502 3 76 ⁄8 x 51⁄2 ⁄8 x 51⁄2 1x4 180 245 220 300 36.928 53.D.5 13.0 2.1 6.66 5.0 300 20.38 101⁄2 267 141⁄8 359 25⁄8 67 ⁄4 x 41⁄2 1x6 130 175 180 245 15. Size In.38 203 81⁄8 206 279 111⁄8 283 54 21⁄8 54 2 2 2 2 2 3 4 4 4 M16 x 85 5 ⁄8 x 31⁄2 M16 x 85 3 135 100 135 175 130 175 3.12 19 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.869 21.38 57⁄8 149 7 83⁄8 213 93⁄4 21⁄8 54 21⁄8 ⁄2 x 3 80 110 100 100 150 130 5.46 0-1⁄32 0-0./kN Range of Pipe End Separation In.8 0.229 81.000 609.6 4 100 51⁄2 O.097 503.854 115. 139.0 24 600 NOTE: 24. For additional details see “Coupling Data Chart Notes” on page 17.2 M20 x 110 M24 x 150 7 10 250 10.38 127⁄8 327 171⁄2 445 25⁄8 67 200 270 250 340 25.500 750 51.126 9.6 165.9 3.7 750 79.79 0-1⁄32 0-0.1 M10 x 63 3 21⁄2 65 3 O.6 11.6 1.500 88./mm 3 Specified Torque § Min.875 73./mm Approx.6 300 20.D.000 355.4 M10 x 63 3 ⁄8 x 21⁄2 76.6 51.09 24.7 46.3 750 51.7 3.anvilintl.750 273.06 17.79 3 76 51⁄8 130 17⁄8 48 2 2 2 2 ⁄8 x 21⁄4 30 40 45 60 1.000 406.79 0-1⁄32 4 102 41⁄8 61⁄8 156 61⁄8 17⁄8 48 17⁄8 30 40 80 45 60 100 2.7 5.6 23.216 32./mm Coupling Dimensions X In.1 6 150 165.1 3 80 76. End Load Lbs.4 35.7 76.1 6.4 300 20.31 0-3⁄32 0-2.7 23.9 3./mm Max.38 271⁄8 689 307⁄8 784 31⁄8 79 1x4 M24 x 100 200 270 250 340 89.23 0-3⁄32 0-2.7 5 125 61⁄2 O.38 0-3⁄32 0-2. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.4 7. 2. Not for use in copper systems.D.79 105 43⁄4 121 156 71⁄4 184 48 17⁄8 48 2 2 2 M10 x 63 1 ⁄2 x 3 M12 x 76 1 110 80 110 150 100 150 1.381 201. In.3 6.996 750 51.341 339.17 0-3⁄32 0-2.38 0-3⁄32 178 7 178 8 248 10 254 11 54 21⁄8 54 21⁄8 2 2 M16 x 85 5 ⁄8 x 31⁄2 M16 x 85 5 ⁄8 x 31⁄2 135 100 135 100 175 130 175 130 3. § – For additional Bolt Torque information.887 0-3⁄32 0-2. Ft.3 5.78 0-1⁄32 0-0.750 323.1 3.0 19.7 750 51.1 500 34. Lbs./mm Coupling Bolts* Z Qty.563 141.5 45.207 0-1⁄32 0-0.94 0-3⁄32 0-2. See Installation & Assembly directions on page 153.-Lbs/N-M Y In./mm 11⁄2 40 1.87 0-3⁄32 0-2. Ea.500 114.323 14.2 300 20.52 7.7 2.000 508.38 15 381 191⁄2 495 25⁄8 67 ⁄8 x 6 180 245 220 300 30.79 31⁄2 89 55⁄8 143 17⁄8 48 ⁄8 x 21⁄2 ⁄8 x 21⁄2 30 40 45 60 2.4 M22 x 140 7 16 400 16. see page 190.7 750 51.1 7.1 M22 x 140 M24 x 100 18 450 18. Working Pressure PSI/bar Max.9 400 27.43 0-3⁄32 0-2.9 51./kg In.500 51.08 0-3⁄32 0-2. Max.58 0-3⁄32 0-2.3 750 51.070 227.1 600 41.181 205.2 113.625 219.6 8 200 8.248 419.5 3.7 94.com GL-7.9 1.6 250 17.couPLInGS For GrooVEd-End PIPE Rigidlok® Coupling Y Z Y Z Y Z X X SIzES 1 1/2" .8 M22 x 150 7 14 350 14.6 12 300 12.3 6.5 Range of Pipe End Seperation values are for roll grooved pipe and may be doubled for cut groove pipe.1 16.056 155.38 23 581 267⁄8 683 31⁄8 79 1x4 M24 x 100 200 270 250 340 68.7 750 4. 7401 X .8 M10 x 57 3 2 50 2.3 31.26 18.9 7.7 60. halogenated hydrocarbons and lubricants.250" or greater • No special fittings needed • No special valves needed • Up to 23% less weight than competitive models • Sizes: 14" through 24" in Rigid: Figure 7401-2 material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated.000 508.6 350 24. on cut or roll grooved pipe with a wall thickness of 0.S.com ./mm In.336 704.4 350 24./DN(mm) O. petroleum oils. HouSInG: Ductile Iron conforming to ASTM A 536./mm In. FIGurE 7401-2 rIGIdLoK couPLInG Y Z Nominal Size In. Grade 65-45-12 coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative./kN In. 7401-2 Rigidlok® Coupling Gruvlok® introduces new 2-piece large diameter standard groove couplings in both rigid and flexible styles • Uses standard grooves (conforming to AWWA C-606) • No special grooves or grooving tools needed • Pressures to 350 P. alkalies solutions.anvilintl.956 489. Ea.I.000 406.11 0-3⁄32 0-2. www.0 350 24. diluted acids. Ft.38 271⁄4 688 311⁄8 791 33⁄16 81 11⁄8 x 51⁄2 – 375 510 425 578 90.18 0-3⁄32 0-2. See technical data section for design factors.9 18 450 18.couPLInGS For GrooVEd-End PIPE fiG.66 0-3⁄32 0-2./mm In. Wt.1 89. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available.000 457.38 185⁄16 465 22 558 3 76 1 x 51⁄2 1 x 51⁄2 – 250 340 300 408 46. Air with oil vapors and vegetable and mineral oils. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110.1 53.6 20 GL-7.000 355./mm In.1 Range of Pipe End Separation values are for roll grooved pipe and may be doubled for cut groove pipe.38 203⁄4 527 241⁄4 615 31⁄8 79 250 340 300 408 62. GASKEt tYPE: Flush Gap (Standard) LuBrIcAtIon: Standard Gruvlok XtremeTM WorKInG PrESSurE. Working Pipe End End Load Separation X Y Z Qty.D.878 239./mm Specified Torque § Approx.2 350 24. NOT FOR USE IN PETROLEUM APPLICATIONS. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids.5 16. or J995 Grade 2.03 0-3⁄32 0-2. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications.1 70.1 109. hydraulic fluids.31 0-3⁄32 0-2.1 158. Min.5 41.5 28. oil-free air and many other chemical services.000 609.372 313.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B.6 350 24. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) Standard -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service.064 396./mm Max.5 33.3 24 600 24. Size Pressure PSI/bar Lbs. In. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended.12 X 16 400 16.38 23 582 271⁄8 691 31⁄8 79 11⁄8 x 51⁄2 – 375 510 425 578 73. Max.-Lbs/N-M Lbs.0 20./kg 14 350 14.3 20 500 20. Contact an Anvil Representative for more information. See Installation & Assembly directions on page 155. Bolts and nuts are provided zinc electroplated as standard. End LoAd & PIPE End SEPArAtIon: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. Range of Coupling Dimensions Coupling Bolts* Max.38 161⁄4 413 193⁄4 502 3 76 2 2 2 2 2 7 ⁄8 x 51⁄2 – – 180 245 220 300 36. Fig. diluted acids. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. are weld-ring couplings.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. www. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Contact an Anvil Representative for availability. sizes 1" through 14" couplings have two 180° segment housings. The coupling design supplies optimum strength for working pressures to 1000 PSl (69 bar) without excessive casting weight. visit our website at www.anvilintl.D. The 28" O. The flexible design eases pipe and equipment installation while providing the designed-in benefit of reducing pipeline noise and vibration transmission without the addition of special components. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. 7001 For Listings/Approval Details and Limitations. and 18" through 24" sizes have four 90° segment housings. while the 28" O. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade 65-45-12 or Malleable Iron conforming to ASTM A 47. Grade “L” Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry. NSF-61 Certified for cold and hot water applications up through 12". couplings have six 60° segment housings. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available.12") Flush Gap (Standard 14" . zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. HouSInG: Ductile Iron conforming to ASTM A 536. oil-free air and many other chemical services. Services include mechanical and plumbing. 7001 Standard Coupling forms a flexible grooved end pipe joint connection with the versatility for a wide range of applications. PIPE End SEPArAtIon & dEFLEctIon FroM cEntEr LInE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. Contact an Anvil Representative for more information. hydraulic fluids.12 Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. process piping. 7001 with Standard Gasket Fig. oil-free air and many other chemical services. halogenated hydrocarbons and lubricants.24".couPLInGS For GrooVEd-End PIPE Standard Coupling The Gruvlok® Fig. Grade 32510.com GL-7. Available 1" . NOT FOR USE IN PETROLEUM APPLICATIONS.D.anvilintl. End LoAd. alkalies solutions. and 30" O. Bolts and nuts are provided zinc electroplated as standard. and 30" O. or J995 Grade 2. See technical data section for design factors. GASKEt tYPE: C Style (Standard 1" . 7001 with Flush Gap Gasket 21 . oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. and many others. To ease coupling handling and assembly and to assure consistent quality. alkalies solutions. Air with oil vapors and vegetable and mineral oils.com or contact an Anvil® Sales Representative. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids.D. petroleum oils. Hex nuts are zinc electroplated followed by a yellow chromate dip.8.D. 16" have three 120˚ segment housings. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. mining and oil field piping. diluted acids. hot air and some high temperature chemical services.12") LuBrIcAtIon: Standard Gruvlok XtremeTM (Do Not use with Grade “L”) WorKInG PrESSurE. 12 .38 0° 49' 0° 37' 0° 30' 0° 25' 0° 23' 0° 20' 0° 18' 0° 16' 0° 13' 0° 11' 0° 10' 14.38 0. * Available in ANSI or metric bolt sizes only as indicated.3 98.4 28.741 207.2 102.0 15.75 0-3⁄32 0-2.164 9. Max.315 33.61 34.500 88.12 33./kN Range of Pipe End Separation In.20 16. End Pressure Load PSI/bar Lbs.2 M22 x 140 12 300 12.38 0.06 5.04 0-1⁄32 0-0.4 300 20.625 168.9 181⁄8 460 227⁄8 581 3 76 200 - 250 - 50.38 0.750 323.0 333⁄4 857 381⁄4 972 35⁄8 92 1 x 51⁄2 * 200 - 250 - 137.7 135.1 3 80 76./mm 1 25 1.24" SIzES 28" .11 8.6 30" I.5 0.0 4.8 M22 x 140 16 400 16.07 5.9 147.3 6.90 0-1⁄32 0-0.79 0° 31' 0° 27' 1° 12' 0° 58' 0° 50' 10.2 300 20.1 800 55.7 9.3 113.9 2.3 151⁄2 394 185⁄8 473 25⁄8 67 ⁄8 x 6 180 245 220 300 35.anvilintl.79 1° 22' 1° 5' 0° 57' 0° 45' 0° 37' 0° 36' 0.904 70.7 M10 x 57 2 50 2.2 211⁄8 537 253⁄8 645 31⁄8 79 1x4 * 200 - 250 - 72.0 32.6 300 20. see page 190.1 6 150 165.9 2. 733.4 150 10.79 0.430 19.9 800 55.375 60.38 0. Max.31 0-3⁄32 0-2. Wt.7 46.4 150 10./ft-mm/m Y In.1 35⁄8 92 61⁄8 156 17⁄8 48 ⁄2 x 3 80 110 100 150 3.7 20 500 20.2 1000 68.0 31⁄2 90 4.141 454.14" SIzES 16" . Not for use in copper systems.4 0.61 0-3⁄32 0-2. 787.621 42.13 10. 2. 22 www.38 0.1 M16 x 89 3 5 125 61⁄2 O.2 46.29 23.9 0./mm Bolt Dimensions* Z Qty.D.04 3.9 1000 68.9 M22 x 150 7 14 350 14.D. Refer to page 196 for Misalignment & Deflection Calculations and page 197 for Curve Layout Calculations.6 300 20.couPLInGS For GrooVEd-End PIPE fiG.58 0-3⁄32 0-2.1 210 85⁄8 219 298 113⁄4 298 51 2 51 2 2 2 2 2 4 4 4 4 6 6 M20 x 110 3 ⁄4 x 41⁄2 M20 x 110 7 175 130 175 245 180 245 5.80 0-0.3 M16 x 89 5 4 100 4.3 1000 68.7 4.4 M12 x 76 1 21⁄2 65 3 O.2 331⁄2 851 351⁄2 902 31⁄8 79 1 x 51⁄2 * 200 - 250 - 105.7 60.3 0.38 0-3⁄32 0.79 0-1⁄32 0.79 0.99 0-3⁄32 0-2.1 2.9 108 47⁄8 124 171 71⁄8 181 48 17⁄8 48 2 2 2 2 2 M12 x 76 1 ⁄2 x 3 M12 x 76 5 110 80 110 150 100 150 2.3 1000 68. In.8 51⁄4 133 81⁄4 210 17⁄8 48 ⁄8 x 31⁄2 ⁄8 x 31⁄2 100 135 130 175 5.43 0-3⁄32 0-2.183 0-3⁄32 0-2.306 108.563 141. For additional details see “Coupling Data Chart Notes” on page 17.70 0-3⁄32 0-2. See page 190 for details.8 28" O.835 12.93 0-3⁄32 0-2.2 72.0 47.13 41⁄4 108 41⁄4 61⁄2 165 63⁄4 17⁄8 48 17⁄8 ⁄2 x 3 80 110 80 100 150 100 3.0 300 20.20 16.8 3.1 3.3 68./mm Deflection from C L Per Coupling Degrees(˚)-Minutes(') Coupling Dimensions X In.6 M10 x 57 3 11⁄4 32 1.0 22.11 8.6 1000 68.4 11.8 5.660 42.38 0.8 M22 x 140 7 10 250 10.050 0-1⁄32 0-0.08 6.8 21⁄2 64 41⁄2 114 17⁄8 48 2 2 2 2 2 2 ⁄8 x 21⁄4 30 40 45 60 1.D.750 273.38 0.9 1000 68.36 9.000 101.8 61⁄4 159 83⁄4 222 2 51 100 135 130 175 6.38 0. Lbs.341 339.9 15.000 355.3 1000 68.06 4.4 1000 68. Size In.9 12.4 31.7 161⁄8 410 201⁄2 521 3 76 ⁄8 x 51⁄2 1x4 * 180 245 220 300 37.181 205.248 419.625 219.23 0-3⁄32 0-2.71 0-1⁄32 0-0.9 68.8 23⁄4 70 41⁄2 114 17⁄8 48 ⁄8 x 21⁄4 ⁄8 x 21⁄4 1 30 40 45 60 1.996 1000 68. 7001 Y X Y Z Standard Coupling Z Y Z X X SIzES 1" .7 94.63 0-1⁄32 0-0.9 1000 24.9 31.9 1000 6.000 406.9 1.6 4.23 18.0 16.875 73.0 800 55.79 0.4 0.7 23 584 281⁄4 718 31⁄8 79 11⁄8 x 41⁄2 * 225 - 275 - 82.2 24 600 24.900 48.4 8 200 8.38 0.566 55.0 62. Ft. 5.25 20.79 0.1 NOTES: Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe./mm Approx.9 4.0 2.38 0.38 0.D.6 M10 x 57 3 11⁄2 40 1.09 7.226 436./mm Max.35 0-3⁄32 0-2.000 457.34 0-2.09 7.7 76.38 0-3⁄32 0-2.610 322.8 M20 x 110 3 ⁄4 x 41⁄2 165.0 40.7 131⁄8 333 165⁄8 422 25⁄8 67 ⁄8 x 51⁄2 7 180 245 220 300 27.D.91 0-3⁄32 0-2.13 10. Ea.500 1000 68.04 3.875 733.5 3 76 45⁄8 117 17⁄8 48 30 40 45 60 1./DN(mm) O.8 0.1 1.7 1.7 18 450 18. § – For additional Bolt Torque information./kg In.com GL-7.79 0-1⁄32 0-0.30" FIGurE 7001 StAndArd couPLInG Nominal Size In.17 14.3 M12 x 76 1 ⁄2 x 3 76. See Installation & Assembly directions on page 154.9 11 279 143⁄8 365 23⁄8 60 ⁄8 x 51⁄2 180 245 220 300 21.472 153.-Lbs/N-m of Pipe In.319 268.9 27 686 323⁄8 822 31⁄8 79 11⁄8 x 41⁄2 * 225 - 275 - 90.05 3./mm 3 Specified Torque § Min.4 11.4 0.492 28.17 71⁄4 184 81⁄4 111⁄4 286 113⁄4 2 51 2 ⁄4 x 41⁄2 130 175 130 180 245 180 9.3 2.16 13.1 6.000 609.500 114.88 7.358 6.0 37.000 508.0 12. Work.717 603.215 503.00 787.61 0-1⁄32 0-0. 38 0-2.05 3.4 18 450 18. End Pressure Load PSI/bar Lbs./mm Degrees(˚)-Minutes(') In.38 0./kg In.1 89. PIPE End SEPArAtIon & dEFLEctIon FroM cEntEr LInE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. End LoAd. Grade 65-45-12 coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative./mm Deflection from C L Per Coupling of Pipe Y Coupling Dimensions X Y Z Bolt Dimensions* Qty.2 350 24./mm In.07 5.000 609.com GL-7./kN Range of Pipe End Separation In. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications.336 0-3⁄32 0.9 271⁄4 311⁄8 33⁄16 425 578 90.1 109.1 53./ft-mm/m In.3 X 16 400 16. Max.878 239. NOT FOR USE IN PETROLEUM APPLICATIONS. Ft.31 0-3⁄32 0-2.064 396.6 350 24.08 6. Contact an Anvil Representative for more information. HouSInG: Ductile Iron conforming to ASTM A 536.38 0° 23' 0° 20' 0° 18' 0° 16' 0° 13' 0.000 406.4 350 24./mm 14 350 14.anvilintl. Wt. Max. Work.0 40.06 5. Min.5 32.0 27.2 20 500 20. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.S. See Installation & Assembly directions on page 155. oil-free air and many other chemical services.9 185⁄16 22 203⁄4 241⁄4 23 582 688 3 76 1 x 51⁄2 1 x 51⁄2 – – – 250 340 300 408 45.1 0. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available./mm In.000 508. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110.000 355.250" or greater • No special fittings needed • No special valves needed • Up to 23% less weight than competitive models • Sizes: 14" through 24" in Flexible: Figure 7001-2 material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated.-Lbs/N-m Lbs.18 489.7 161⁄4 193⁄4 413 465 527 502 558 615 3 76 2 2 2 7 ⁄8 x 51⁄2 – – 180 245 220 300 36.03 0-3⁄32 0-2. Ea. diluted acids.9 24 600 24. GASKEt tYPE: Flush Gap (Standard) LuBrIcAtIon: Standard Gruvlok XtremeTM WorKInG PrESSurE.38 0-2. Size In. or J995 Grade 2.0 16.06 4. on cut or roll grooved pipe with a wall thickness of 0.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. halogenated hydrocarbons and lubricants.11 704. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) Standard -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. See technical data section for design factors./mm Specified Torque § Approx.8 Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. hydraulic fluids. FIGurE 7001-2 StAndArd couPLInG Z Nominal Size O. Max.0 350 24.0 20.000 457. alkalies solutions. Bolts and nuts are provided zinc electroplated as standard.I. 7001-2 Gruvlok® introduces new 2-piece large diameter standard groove couplings in both rigid and flexible styles • Uses standard grooves (conforming to AWWA C-606) • No special grooves or grooving tools needed • Pressures to 350 P.372 313.6 350 24. petroleum oils. www.38 0.7 271⁄8 691 791 31⁄8 79 81 2 11⁄8 x 51⁄2 375 2 11⁄8 x 51⁄2 375 425 578 72.66 0-3⁄32 0-2. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids./DN(mm) In. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended.1 70.D. Air with oil vapors and vegetable and mineral oils.2 31⁄8 79 250 340 510 510 300 408 60.couPLInGS For GrooVEd-End PIPE Standard Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.12 23 .956 0-3⁄32 158. oval neck track bolts of carbon steel conforming to ASTM A 183 Grade 2. Each housing segment is machined to assure a close dimensional fit with pipe ends that are prepared in accordance with Gruvlok “Large Diameter Roll and Cut Groove Specifications.couPLInGS For GrooVEd-End PIPE fiG. easy and quick.anvilintl. 7011 Standard Coupling The Gruvlok® Figure 7011 Standard Coupling is a flexible coupling designed to join roll grooved or cut grooved 30" O. 24 www. For Gruvlok gasket material recommendations see the Gruvlok catalog. grinding the weld seam on the interior and exterior of the pipe may be required. including Commercial/Industrial Construction.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563. The gasket is available in EPDM and Nitrile. The operating pressure ranges 15" of Hg. Mining.com GL-7. pipe for a wide range of applications.12 . with a minimum tensile strength of 110. Not performing this operation may result in improper assembly of the coupling. Bolts and nuts are zinc plated per ASTM B 633 as standard. Process Piping and many others. material specifications HouSInG dESIGn: This six-segment coupling housing is cast in ductile iron per ASTM A 536 Grade 65-45-12. This coupling’s operating temperature ranges from –40°F to 230°F (-40°C to 110°C) with the Grade E EPDM gasket and –20°F to 180°F (-29°C to 82°C) with the Grade T Nitrile gasket. It is critical that the pipe ends be prepared in accordance with the Gruvlok “Large Diameter Roll and Cut Groove Specifications.D. to facilitate use in a wide range of applications. PIPE End PrEPArAtIon: Pipe grooving is simple. gasket leakage and damage to the roll grooving machine. BoLtS & HEAVY HEX nutS: Heat treated.” For roll grooved pipe. vacuum to 300 psig on standard wall steel pipe.” GASKEt dESIGn: The gasket design is a “C” Style cross section and features a larger cross section to provide optimal sealing throughout the range of pipe dimensional variations and operating conditions. 88 29./mm Specified Torque § Min.0 0.D.500 749. In.60 0./mm 30 O. is to be measured from the pipe end to the vertical flank in the groove. prior to roll grooving.com GL-7.35 0. seams.54 ±.12 25 ./mm Coupling Bolts* Qty.30 0.D. however square cut is preferred.D. 600 - of Pipe In.77/-1. 6 Size In.D.250 6.06 4. • Groove width.031 0. * Available in ANSI or metric bolt sizes only as indicated.7 34 864 391⁄2 1003 5 127 11⁄4 x 43⁄8 – 200 90.2 0-9⁄64 0-3. End Load Lbs.see page 190. For additional details see “Coupling Data Chart Notes” on page 17.030 +./Kg Ft. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG./mm In. In. SPECIAL ROLL GROOVING INSTRUCTION: • Weld seams must be ground flush with the pipe O.000 Roll Groove Cut Groove In. which may interfere with proper sealing of the gasket.anvilintl. • Out of Roundness: Difference between the maximum and minimum pipe O. Ea.058 943. must be within specified dimensions. Only) Tol +0./kN Range of Pipe End Separation In. See Installation & Assembly directions on page 156./mm Groove Diameter “C” Actual In./mm In.7 212. rust or other scale. 30./DN(mm) O. • The maximum allowable tolerance from square cut ends is .D. 750 30. Gasket Seat width. • Gasket Seat must be free from scores./mm -In. Actual In.250 6. 800 - Approx.57 0° 16' 0.79 1.030/-.750 44.couPLInGS For GrooVEd-End PIPE Standard Coupling Y Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.0 Working pressure and end load values are for standard wall pipe.77 In. and I.125” measured from a true square line.9 762. Lbs./DN(mm) O./mm Max. Working Pressure PSI/bar Max. dimension A./N-m 30 O./mm Z In.25 (371⁄2° ) is acceptable.063 1./mm Deflection from C L Per Coupling Degrees(˚)-Minutes(') Coupling Dimensions X In. A B T A B T Flare OD OD C Roll Groove D C Cut Groove D LArGE dIAMEtEr PIPE roLL & cut GrooVE SPEcIFIcAtIonS Nominal IPS Pipe Size In. Range of pipe end separation values are for cut grooved pipe./mm -In.093 2./mm Max. Wt.D. tolerance listed ( Reference column 2). dimension B.060 ±.-Lbs. Wall Thickness “T” (Ref. www. Roll and Cut Grooving Specifications can be found in the technical data section.000 750 NOTE: 300 20.D. 7011 Z X FIGurE 7011 StAndArd couPLInG Nominal Size In. chips.88 30.45 0. • Groove depth must be uniform depth around the entire pipe circumference.625 15.000 762./mm Groove Depth “D” Min.35 0. • Beveled end pipe in conformance with ANSI B16.1 • Pipe O.200 767./mm Max.) • Maximum Flare Diameter is to be measured at the most extreme pipe end. Flare Dia. (Reference column 6. § – For additional Bolt Torque information.D./ft-mm/m Y In./mm In.36 0./mm Gasket Seat “A” Groove Width “B” +. measured at 90° must not exceed the total pipe O./mm Tolerance +In. is to be measured between the vertical flank of the groove side walls.D.625 15. Failure to do so may result in damage to the roll grooving machine and unacceptable roll grooves may be produced. com or contact an Anvil® Sales Representative. The Fig. 7000 Lightweight Flexible Coupling The Fig. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available.com GL-7. NSF-61 Certified for cold and hot water applications up through 12". oil-free air and many other chemical services.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.12 . 7001 Coupling. diluted acids. oil-free air and many other chemical services. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. GASKEt tYPE: Standard C Style Flush Gap (1" . Grade “T” Nitrile (Orange color code) 20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. 7000 Lightweight Flexible Coupling is designed for applications where system flexibility is desired. See gasket Grade Index for gasket recommendations. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. air with oil vapors and vegetable and mineral oils. See technical data section for design factors. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. Contact an Anvil Representative for more information. or J995 Grade 2. hot air and some high temperature chemical services. The Figure 7000 Lightweight Flexible Coupling is intended for use in several applications. 7000 Coupling is approximately 30% lighter in weight than the Fig. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. For Listings/Approval Details and Limitations. NOT FOR USE IN PETROLEUM APPLICATIONS. hydraulic fluids. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) -20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids.4 bar). For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. diluted acids. NOT FOR USE IN PETROLEUM APPLICATIONS.anvilintl.8") LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) 26 www. HouSInG: Ductile Iron conforming to ASTM A 536. halogenated hydrocarbons and lubricants. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. visit our website at www.8.couPLInGS For GrooVEd-End PIPE fiG. and allows for working pressure ratings up to 600 psi (41.anvilintl. petroleum oils. alkalies solutions. Grade 65-45-12 coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. alkalies solutions. Bolts and nuts are provided zinc electroplated as standard. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. Grade “L” Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry. 38 0-3⁄32 0-2.625 219.couPLInGS For GrooVEd-End PIPE Lightweight Flexible Coupling Y Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.79 0-1⁄32 0-0.1 3./DN(mm) O.4 600 41.D.9 0.4 0.0 0.4 18.68 0-0. Wt.16 13.7 M10 x 57 3 2 50 2.563 141.250 600 41.8 23⁄8 60 41⁄4 108 13⁄4 44 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 1.95 0-3⁄32 0-2.4 600 3.2 6.57 0-1⁄32 0-0.13 10.9 0.25 20.5 0.6 M10 x 57 3 11⁄4 32 1.D.766 0-2.500 88.6 2.0 61⁄2 O./mm Max./Kg Ft.375 60.153 54.2 600 41.8 0.82 0-1⁄32 0-0.1 3.543 42. 7000 Z X FIGurE 7000 couPLInG Nominal Size In. 2.3 5.79 0-1⁄32 0.20 16.26 51⁄8 130 51⁄2 75⁄8 194 73⁄4 13⁄4 44 2 ⁄2 x 3 ⁄2 x 3 80 110 80 100 150 100 3.8 4.299 5.6 6 139./mm Max.5 500 34./mm Degrees(˚)-Minutes(') In.D.701 7.8 0. Lbs. 45 60 Approx.38 0° 49' 0° 37' 13.7 6. See Installation & Assembly directions on page 157.592 0-2.658 11.79 0.20 16.996 600 41.540 33.0 4 100 51⁄4 O.625 168.3 6.11 8. Refer to page 196 for Misalignment & Deflection Calculations and page 197 for Curve Layout Calculations.500 34.18 171 7 178 71⁄2 238 95⁄8 244 103⁄8 51 2 51 2 2 2 2 M16 x 85 5 ⁄8 x 31⁄2 M16 x 85 5 135 100 135 100 175 130 175 130 2.000 101.38 0-3⁄32 1° 12' 1° 2' 0° 59' 22.86 9.8 0.1 0.5 500 34.D. Not for use in copper systems.3 0.315 33.4 500 37. 30 40 Y In.9 2.0 2.38 0-3⁄32 0° 58' 0° 51' 0° 50' 17.13 10.13 4 102 4 53⁄4 146 61⁄8 13⁄4 44 13⁄4 30 40 30 45 60 45 1.23 18.9 102 45⁄8 117 156 63⁄4 171 44 13⁄4 44 2 2 2 M10 x 57 1 ⁄2 x 23⁄4 M12 x 70 1 40 80 110 60 100 150 1.500 114.9 41.512 0-1⁄32 0-0.0 7.33 4.5 29.67 0-2. see page 190.0 0.5 500 52.5 3 76 45⁄8 117 13⁄4 44 30 40 45 60 1.875 73.4 600 41.4 815 3. Ea./mm Z In.8 6.43 16./mm Coupling Bolts Qty. 4.4 2.7 5.660 42.1 3 80 76.3 600 41.879 0-2.4 M20 x 110 NOTES: Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe.259 34.7 8 200 8.0 6.773 25. Pipe End Load Pressure Separation Per Coupling of Pipe PSI/bar Lbs.5 500 47.38 0-3⁄32 17.9 0.6 4.4 1. of Deflection from C L End Range Working Max. In.45 10.79 0° 31' 0° 27' 1° 16' 10. 159.3 600 41.7 ⁄8 x 31⁄2 ⁄8 x 31⁄2 159. § – For additional Bolt Torque information./N-m 1 25 1.0 51⁄2 O.230 0-1⁄32 0-0.-Lbs. 139.21 140 57⁄8 149 61⁄2 197 81⁄8 206 91⁄8 51 2 51 2 2 2 2 M12 x 76 1 ⁄2 x 3 M12 x 76 5 110 80 110 100 150 100 150 130 1./kN In.1 2.38 0-3⁄32 14.89 11.5 73.4 0.1 6 150 165.500 34. 2 2 2 2 2 2 3 Specified Torque § Min.0 5.384 0-2.11 27 .78 0-1⁄32 0-0.3 34.0 165.7 5 125 61⁄4 O.D.7 ⁄8 x 31⁄2 ⁄8 x 31⁄2 133.79 0.1 500 34.62 0-1⁄32 0-0./ft-mm/m Coupling Dimensions X In. For additional details see “Coupling Data Chart Notes” on page 17.8 M10 x 57 3 21⁄2 65 3 O. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.9 1.80 17.79 1° 22' 1° 5' 0° 57' 0° 45' 0° 37' 0° 36' 0.236 41.895 17.236 76.1 6.2 8.7 0.1 31⁄2 89 51⁄2 140 13⁄4 44 30 40 45 60 1.1 1.06 15.8 23⁄4 70 43⁄8 111 13⁄4 44 30 40 45 60 1./mm Size In.79 0.anvilintl.17 14.4 1.4 600 7.82 5.213 129.09 7.0 4.D.29 23.D.84 12. See page 190 for details.3 31⁄2 90 41⁄4 O.20 165 63⁄4 232 93⁄8 51 2 M16 x 85 5 135 100 175 130 2.79 0-3⁄32 0.1 197 8 203 273 11 279 51 2 51 2 2 M16 x 85 5 ⁄8 x 31⁄2 M16 x 85 3 135 100 135 175 130 175 3.5 500 68.com GL-6.9 101⁄2 264 1213⁄16 337 21⁄2 60 ⁄4 x 41⁄2 130 175 180 245 14.17 191 73⁄4 264 103⁄4 51 2 M16 x 85 5 135 100 175 130 3.4 600 41. www.38 0-3⁄32 0-2.38 0.900 48.1 5.38 0-3⁄32 0-2.0 2.54 8. 133.6 M10 x 57 3 11⁄2 40 1.0 M12 x 76 1 108.9 0.4 4. 108.3 M10 x 57 3 76. diluted acids. 7400 Rigidlite Coupling from Gruvlok is specially designed to provide a rigid. visit our website at www. NSF-61 Certified for cold and hot water applications up through 12". Grade “L” Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry. HouSInG: Ductile Iron conforming to ASTM A 536. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated.7 bar) with roll grooved or cut grooved steel pipe prepared in accordance with Gruvlok grooving specifications. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. Bolts and nuts are provided zinc electroplated as standard. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. halogenated hydrocarbons and lubricants. hydraulic fluids. Fast and easy swing-over installation of the rugged lightweight housing produces a secure. locked-in pipe connection to meet the specific demands of rigid design steel pipe systems. 7400 Rigidlite Coupling is UL/ULC Listed and FM Approved for 300 psi (20. hot air and some high temperature chemical services. NOT FOR USE IN HOT WATER OR HOT AIR Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids.couPLInGS For GrooVEd-End PIPE fiG. petroleum oils.8") LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) 28 www. The Fig. rigid pipe joint. alkalies solutions. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended.com GL-7.12 . GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. The Fig. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. Contact an Anvil Representative for more information. oil-free air and many other chemical services. Grade 65-45-12.anvilintl. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKEt tYPE: Standard C Style Flush Gap (1" .anvilintl. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available.com or contact an Anvil® Sales Representative. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. air with oil vapors and vegetable and mineral oils. NOT FOR USE IN PETROLEUM APPLICATIONS. alkalies solutions. 7400 Rigidlite® Coupling DN 50 and DN 200 sizes are VdS approved. oil-free air and many other chemical services. or J995 Grade 2.8. For Listings/Approval Details and Limitations.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. diluted acids. 97 0-3⁄32 0-2./mm Specified Torque § Y In.79 102 41⁄2 114 149 63⁄4 171 44 13⁄4 44 2 2 2 M10 x 57 3 ⁄8 x 23⁄4 M10 x 70 3 40 30 40 60 45 60 0. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.3 0.329 5. Lbs.0 4 100 51⁄2 O.1 6 150 165.955 0-2.7 1.7 9.38 0-3⁄32 0-2.81 0-1⁄32 0-0.341 46.948 8. * DN 50 and DN 200 sizes are VdS approved.6 0.D.315 33.79 21⁄4 57 41⁄2 114 13⁄4 44 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 1.1 5.5 2.D.6 M10 x 57 3 2 50* 2./Kg Ft.3 300 20.9 1.886 12.7 5.38 200 77⁄8 200 264 103⁄8 264 51 2 51 2 2 M12 x 76 1 ⁄2 x 3 M12 x 76 1 110 80 110 150 100 150 2.1 1.500 300 20.996 300 20. 7400 X FIGurE 7400 rIGIdLItE couPLInG Nominal Size In.9 M10 x 57 3 ⁄8 x 21⁄4 76.44 9.7 300 1./mm Coupling Bolts Z In.292 32.3 5.anvilintl.D. 2.500 114.28 10. Ea.500 20.7 5 125 61⁄2 O.79 25⁄8 67 43⁄4 121 13⁄4 44 30 40 45 60 1.41 2. Wk. 45 60 Approx./kN Range of Pipe End Separation In.7 851 3.4 3.5 M10 x 70 1 ⁄2 x 3 139. § – For additional Bolt Torque information.660 42./mm Coupling Dimensions X In.9 2.1 1. For additional details see “Coupling Data Chart Notes” on page 17.79 27⁄8 73 47⁄8 124 13⁄4 44 30 40 45 60 1.00 0-2. End Load Lbs.couPLInGS For GrooVEd-End PIPE Rigidlite® Coupling Y Z Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.1 3 80 76.3 300 20. Pressure PSI/bar Max.3 6.91 0-1⁄32 0-0.4 4.6 M10 x 57 3 11⁄2 40 1. In.9 20.84 0-0.115 0-1⁄32 0-0.625 219.38 101⁄4 260 123⁄4 324 23⁄8 60 ⁄2 x 3 80 110 100 150 8.22 7.2 300 20.5 M10 x 57 3 11⁄4 32 1.7 300 20.900 48.528 77.7 300 4. 4.79 0-1⁄32 37⁄8 98 4 6 152 5 7⁄8 13⁄4 44 13⁄4 30 40 30 45 60 45 1.com GL-6.79 0-1⁄32 0-0.7 300 20.625 168.8 M12 x 76 Range of Pipe End Seperation values are for roll grooved pipe and may be doubled for cut groove pipe./DN(mm) O.875 73.38 0-3⁄32 171 67⁄8 175 73⁄4 235 91⁄4 235 103⁄8 51 2 51 2 2 2 M12 x 76 1 ⁄2 x 3 M12 x 76 1 ⁄2 x 3 110 80 110 80 150 100 150 100 2.3 20./mm Qty.11 29 .7 300 20.5 165. Other sizes available.5 8 200* NOTE: 8.D. see page 190.38 0-3⁄32 55⁄8 143 63⁄4 73⁄4 197 91⁄4 17⁄8 48 2 ⁄8 x 23⁄4 30 40 80 45 60 100 3.7 649 2.7 17.771 21.0 2.375 60. www.70 7./mm Min.2 0./N-m 1 25 1.38 0-3⁄32 0-2.1 6.-Lbs. See Installation & Assembly directions on page 158. Wt.1 3.1 300 20.89 0-1⁄32 0-0. 2 2 2 2 2 2 3 Size In.4 0. 30 40 Max.563 141.500 88. 139.0 4.5 5.66 2.9 0.6 2.7 407 1.127 0-3⁄32 0-2.4 300 20.7 M10 x 57 3 21⁄2 65 3 O.7 300 31.79 31⁄4 83 51⁄2 140 13⁄4 44 30 40 45 60 1./mm Max. contact an Anvil Representative for more information.78 0-1⁄32 0-0.7 44. 8": Cast Ductile Iron Handles LInKS: Sizes 1" . 7003 Hingelok Coupling halves are permanently hinged to provide an assembly that eases handling and installation.4": Cold Rolled Carbon Steel Links Sizes 5" . NOT FOR USE IN PETROLEUM APPLICATIONS. 7003 Hingelok Coupling provides for system working pressure ratings up to 300 psi (20.7 bar). Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids. oil-free air and many other chemical services.8" material specifications HouSInG: Ductile Iron conforming to ASTM A 536. NSF-61 Certified for cold and hot water applications up through 12". The Fig. coAtInGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative.4": Cold Rolled Carbon Steel Handles Sizes 5” . The cam-action locking handle permits rapid installation without the need for additional tools and maintains secure closure of the coupling into the pipe grooves. air with oil vapors and vegetable and mineral oils. Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. halogenated hydrocarbons and lubricants.anvilintl.com GL-7. hydraulic fluids. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. NOT FOR USE IN HOT WATER OR HOT AIR. DO NOT USE GRUVLOK XTREME LUBRICANT WITH GRADE “L” SILICONE GASKET.8") LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) 30 www.12 .4" The Fig.8": Heat Treated Steel Links LocKInG PIn: Locking Pin: Spring Steel GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. oil-free air and many other chemical services. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. 7003 Hingelok® Coupling SIzES 1" . diluted acids. NOT FOR USE IN PETROLEUM APPLICATIONS. Sizes 1" to 4" use toggle link plates and sizes 5" to 8" use a toggle bolt to attach the cam-action handle to the housings. diluted acids. HAndLE: Sizes 1" . Final assembly of the locking pin to the Hingelok Coupling adds an extra measure of security required in critical pipe joint applications.couPLInGS For GrooVEd-End PIPE fiG. The Fig. alkalies solutions. 7003 Hingelok Coupling is ideal for those applications where frequent pipe removal is required for maintenance or any other reason. The two coupling halves are hinged for ease of handling and are secured by a cam-action handle. hot air and some high temperature chemical services. Fig. Grade “L” Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry. petroleum oils. 7003 Hingelok Coupling is specially designed for applications requiring a quick connection and/or disconnection of a pipe joint. alkalies solutions. SIzES 5" . Grade 65-45-12. GASKEt tYPE: Standard C Style Flush Gap (1" . 292 32.7 17.563 141.38 0.6 1.0 21⁄2 65 2.1 8 200 8. When re-using.84 0-1⁄32 0-0.500 88.D.16 13.7 407 1.23 18. Wk.78 0-1⁄32 0-0. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.7 2.25 20. Pressure PSI/bar Max.3 300 20.900 48.44 0-3⁄32 0-2.13 10.8 3 76 4 101 1 ⁄4 3 1.500 114.8 7 178 73⁄4 197 2 51 5./mm Max. End Load Lbs.886 12.9 55⁄8 143 61⁄2 165 17⁄8 48 3.12 31 .6 0-0. For additional details see “Coupling Data Chart Notes” on page 17.1 2.5 0. 7003 Z X FIGurE 7003 HInGELoK couPLInG Nominal Size In.948 8.11 8.1 8.8 85⁄8 219 91⁄2 241 21⁄8 54 9.3 6 150 6.5 3 80 3.79 0.315 33. CAUTION: Hammering or banging on the handle or coupling housing could cause serious damage to the locking device and coupling assembly.528 77.771 21.3 300 20.79 0.38 0. www.97 0-3⁄32 0-2.79 0.14 97⁄8 251 107⁄8 276 21⁄8 54 11.00 0-3⁄32 0-2.79 0.1 300 20.6 4 100 4.20 16.⁄32 1 1° 22' 1° 5' 0° 57' 0° 45' 0° 37' 0° 31' 1° 12' 0° 58' 0° 49' 0° 37' 0.89 0-1⁄32 0-0.7 1.2 1.660 42. See Installation & Assembly directions on page 160.341 46./mm Deflection from C L Per Coupling Degrees(˚)-Minutes(') Coupling Dimensions X In. and pipe grooves must be kept free of all foreign matter. always check for gasket damage. Proper anchoring practice must always be exercised.5 35⁄8 92 41⁄4 108 17⁄8 48 1.79 44 11⁄4 32 1.7 4.7 0. Wt.79 0.9 300 20./ft-mm/m Y In. SPECIAL NOTE: Fig.29 23. Shockload must be considered and is to be included in the maximum working pressure listed above.91 0-1⁄32 0-0. 7003 Hingelok Couplings are not designed for eccentric loading and therefore are not recommended for use at the end of concrete pumping booms or vertical risers above 30 feet (9. See page 190 for details. Not for use in copper systems. distortion.1 41⁄4 108 47⁄8 124 17⁄8 48 2./mm Z In./Kg 1 25 1.couPLInGS For GrooVEd-End PIPE Hingelok® Coupling Y Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.2 300 20./mm Approx.3 300 20.3 300 20. gasket cavity. Refer to page 196 for Misalignment & Deflection Calculations and page 197 for Curve Layout Calculations.38 0.9 12 305 131⁄8 333 21⁄2 64 18. In.7 7. Coupling keys.7 10.7 851 3.22 0-3⁄32 0-2./DN(mm) O.2 1. Lbs.4 300 20.8 37⁄16 87 47⁄16 113 17⁄8 48 1.20 16.3 300 20.875 73.5 4.7 649 2.2 5.1 meters)./kN Range of Pipe End Separation In.38 0.81 0.8 2 50 2.329 5.0 300 20.13 10.7 1. bending or any other damage.625 168.375 60.9 51⁄4 133 57⁄8 149 17⁄8 48 3.3 5 125 5.anvilintl. The result may be an unsuitable pipe joint and unusable coupling assembly. Ea.625 219.7 11⁄2 40 1.17 14.66 0-1⁄32 0-0. housing hinge and handle for looseness.2 NOTES: Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe.com GL-7./mm of Pipe In.4 0. com GL-7.12 . MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. Grade 32510. air with oil vapors and vegetable and mineral oils. diluted acids. coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative.anvilintl.com or contact an Anvil® Sales Representative. Contact an Anvil Representative for more information. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. alkalies solutions. or J995 Grade 2. NOT FOR USE IN PETROLEUM APPLICATIONS. 7010 Reducing Coupling The Fig. diluted acids.8. alkalies solutions. HouSInG: Ductile Iron conforming to ASTM A 536. visit our website at www. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. 7010 Reducing Coupling makes it possible to directly connect two different pipe sizes. NOT FOR USE IN HOT WATER OR HOT AIR. NSF-61 Certified for cold and hot water applications up through 12".000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. Bolts and nuts are provided zinc electroplated as standard. For Listings/Approval Details and Limitations.couPLInGS For GrooVEd-End PIPE fiG. NOT FOR USE IN PETROLEUM APPLICATIONS.anvilintl. 7010 Reducing Coupling allows for working pressure ratings up to 500 PSI (34. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. Grade 65-45-12. Hex nuts are zinc electroplated followed by a yellow chromate dip. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. oil-free air and many other chemical services.5 bar). GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. Fig. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. The specially designed reducing coupling gasket with a center rib assures proper positioning of the gasket and prevents the smaller pipe from telescoping into the larger during assembly. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. eliminating the need for two couplings and a reducing fitting. LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) 32 www. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. or Malleable Iron conforming to ASTM A 47. oil-free air and many other chemical services. 500 114.1 1.17 14./N-m Lbs.9 101⁄2 267 14 356 21⁄4 57 130 175 180 245 17./ft-mm/m Coupling Dimensions X In.3 5.500 88. 2 2 2 2 2 2 2 2 2 2 2 1 Y In.37 0-3⁄32 0-2.562 141./mm Coupling Bolts Qty./Kg 2 x 11⁄2 50 x 40 2. Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe.17 14.3 1.375 60.875 73.875 73.couplings for grooved-end pipe Reducing Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.5 29.8 61⁄4 159 87⁄8 225 2 51 100 135 130 175 6.6 M16 x 95 5 4x3 100 x 80 4. 7010 Coupling with Gasket figure 7010 reducing coupling Nominal Size In. End Range of Working Pipe End O.3 500 34. For additional details see “Coupling Data Chart Notes” on page 17.7 3. Max.246 14.952 35. www.4 6.236 76.11 8.5 6.5 7.3 500 34.1 M20 x 115 3 8x6 200 x 150 8.5 2.3 500 34.500 88.3 2.85 0-1⁄32 0-0.0 500 34.500 114.38 0.563 141.4 2. In. Refer to page 196 for Misalignment & Deflection Calculations and page 197 for Curve Layout Calculations.9 47⁄8 124 71⁄8 181 17⁄8 48 80 110 100 150 4.0 M16 x 95 5 4 x 21⁄2 100 x 65 4.37 0-3⁄32 0-2.25 20.500 88.16 13.811 21.5 7.79 0° 45' 0° 37' 0° 31' 0° 31' 1° 12' 1° 12' 1° 12' 1° 58' 0° 49' 0° 49' 0° 37' 0. Contact your Anvil Representative for details./mm Z In. Pressure Load Separation Per Coupling of Pipe In. § – For additional Bolt Torque information.3 3.500 114.375 60.38 0.0 2.5 17.625 219.4 5.215 9.500 114.38 0.1 M20 x 115 3 6x5 150 x 125 6. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Fig.3 500 34.5 1.375 60.20 16.9 M12 x 76 5 4x2 100 x 50 4./mm Deflection from C L Smaller Max./mm PSI/bar Lbs.anvilintl.625 168.8 61⁄4 159 87⁄8 225 2 51 100 135 130 175 8.9 M12 x 76 1 21⁄2 x 2 65 x 50 2.D.0 0.38 0.5 4. Ea. See Installation & Assembly directions on page 161.153 54.11 8./mm Specified Torque § Approx.38 0.0 500 34.9 4.06 0-3⁄32 0-2.40 0-1⁄32 0-0.3 500 34. Wt. see page 190. Min. Max.3 500 34.0 M16 x 95 3 5x4 125 x 100 5.5 4.3 4.1 81⁄4 210 115⁄8 295 21⁄8 54 130 175 180 245 13. 7010 Fig.875 73.8 61⁄4 159 87⁄8 225 2 51 100 135 130 175 7.500 114.67 0-3⁄32 0-2. See page 190 for details.67 0-3⁄32 0-2.375 60.6 M12 x 76 1 3x2 80 x 50 3.13 10.40 0-1⁄32 0-0./DN(mm) Larger O.0 M12 x 76 1 3 x 21⁄2 80 x 65 3.1 35⁄8 92 57⁄8 149 17⁄8 48 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄8 x 31⁄2 ⁄8 x 31⁄2 ⁄8 x 31⁄2 ⁄4 x 41⁄2 ⁄4 x 41⁄2 ⁄4 x 41⁄2 ⁄4 x 41⁄2 80 110 100 150 2.8 71⁄4 184 105⁄8 270 21⁄8 54 130 175 180 245 11.25 20.79 0.com GL-10.9 2.9 2.952 35.1 81⁄2 216 115⁄8 295 21⁄8 54 130 175 180 245 13.25 20.625 168.37 0-3⁄32 0-2.13 10.79 0.38 0.12 33 .952 35.44 0-1⁄32 0-0./kN In.213 129.-Lbs.2 M20 x 115 3 6x4 150 x 100 6.811 21.9 47⁄8 124 71⁄8 181 17⁄8 48 80 110 100 150 4.7 8. Ft.D.236 76. 7010 Reducing Coupling should not be used with end caps in systems where a vacuum may be developed.900 48.5 12./mm Degrees(˚)-Minutes(') In.79 0.1 6.3 500 34.9 500 34.0 M20 x 115 NOTES: Fig.625 168.5 17.3 500 34.38 0.95 0-3⁄32 0-2.3 4.3 2.9 3.5 3.5 7./mm Size In.9 41⁄4 108 63⁄8 162 17⁄8 48 80 110 100 150 3. Not for use in copper systems. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service.) For Listings/Approval Details and Limitations. or J995 Grade 2. HouSInG: Ductile Iron conforming to ASTM A 536. alkalies solutions. All Gruvlok Fig. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. visit our website at www. 7012 Flange are cast in four segments. 7012 Flanges have designed-in anti-rotation tines which bite into and grip the sides of the pipe grooves to provide a secure. diluted acids. air with oil vapors and vegetable and mineral oils. Hex nuts are zinc electroplated followed by a yellow chromate dip. oil-free air and many other chemical services. in place of the steel adapter insert. NOT FOR USE IN HOT WATER. NSF-61 Certified for cold and hot water applications up through 12". and are drawn together by a latch bolt which eases assembly on the pipe. Precision machined bolt holes. Grade 65-45-12.12 . The two interlocking halves of the 2" thru 12" sizes of the Gruvlok Flange are hinged for ease of handling. 7012 Flange allows direct connection of Class 125 or Class 150 flanged components to a grooved piping system. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. The Gruvlok Fig. Sizes 2" .24"): Heat treated. diluted acids.com or contact an Anvil® Sales Representative. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. lug. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. oil-free air and many other chemical services. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. NOT FOR USE IN PETROLEUM APPLICATIONS. LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) 34 www.anvilintl. and wafer styles of pipe system equipment. key and mating surfaces assure concentricity and flatness to provide exact fit-up with flanged. A sleek profile gasket design allows quick and easy assembly of the Gruvlok Flange onto the pipe. carbon steel oval neck track bolts conforming to ASTM A 183 and zinc electroplated heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. The 14" thru 24" sizes of the Gruvlok Fig. (See Installation and Assembly Instructions Section or contact your Anvil Rep. Red (optional) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative.8.24" material specifications LAtcH BoLt/nut (2" .com GL-7.anvilintl. 7012 Gruvlok Flanges The Gruvlok® Fig. In copper systems a phenolic adapter insert is required. A specially designed gasket provides a leak-tight seal on both the pipe and the mating flange face. for details. 7012 Flange requires the use of a steel adapter insert when used against rubber faced surfaces.12" Sizes 14" . Contact an Anvil Representative for more information. zinc electroplated. alkalies solutions. rigid connection. coAtInGS: Rust inhibiting paint – Color: ORANGE (standard).couPLInGS For GrooVEd-End PIPE fiG. wafer/lug design valves and serrated or irregular sealing surfaces.12") SEGMEnt BoLt/nut (14" . End Load ▼ Lbs. Ft.2 ⁄8 165.9 M10 x 70 300 14 350 323.00 M10 x 70 3 ⁄8 x 23⁄4 M10 x 70 3 40 30 40 60 45 60 286 11 279 356 14 356 22 7 ⁄8 22 168 65⁄8 168 198 713⁄16 198 8 8 8 M20 x 80 3 ⁄4 x 31⁄8 M20 x 80 3 91⁄2 241. § – For additional Bolt Torque information. For additional details see “Coupling Data Chart Notes” on page 17.000 406./mm In.84 M10 x 70 3 ⁄8 x 23⁄4 M10 x 70 3 40 30 40 60 45 60 184 77⁄8 200 248 101⁄2 267 19 3 ⁄4 19 3 76 31⁄2 89 105 49⁄16 116 4 4 8 M16 x 70 5 ⁄8 x 23⁄4 M16 x 70 5 6 152.D./mm 3 2 50 2.9 12.7 9./mm Y In.500 114.3 20./mm Qty.58 ⁄4 x 5 - 130 176 180 244 25 635 29 737 15⁄8 41 18 457 20 508 16 - 11⁄8 x 43⁄4 – 223⁄4 577.1 300 20.563 141.4 300 20. See Installation & Assembly directions on page 162-163.9 - ⁄8 - 298 220 298 220 339 250 339 250 7.3 M10 x 70 3 M20 x 90 7 12 300 12 (PN) 12.750 323.2 1. B Min./Kg In.08 7 ⁄8 x 51⁄2 - 180 244 220 298 32 813 361⁄2 927 17⁄8 48 24 610 26 660 20 - 11⁄4 x 51⁄2 - 291⁄2 749.625 168.500 20.2 113.0 2.500 300 20.1 3.38 38.0 9.92 620 841 1./mm In.292 32.anvilintl.5 - 110 149 220 140 190 250 6./mm 3 Dimensions Max.528 77.4 ⁄4 ⁄4 149 110 149 190 140 190 2.1 3 21⁄2 65 3 O.6 20. * Available in ANSI or metric bolt sizes only as indicated.303 30 40 30 45 60 45 19 483 18 1⁄8 213⁄4 552 21 1⁄4 11⁄4 32 1 123⁄4 324 12 3⁄4 141⁄8 359 14 1⁄8 12 12 12 17 431. flanges cannot be assembled directly to Series 7700 butterfly valve.D. In. ANSI PN10 (16) Mating Flange Bolts Mating Flange Bolts Size (ANSI) in.9 76.4 - 320 439 320 400 542 400 29.7 300 38.7 22.6 250 17.2 300 20.8 450 610 725 983 106./mm Bolt Circle Bolt Hole Diameter Diameter In.5 37.66 2.8 16 400 16.1 8./mm 3 Specified Torque § Min./DN(mm) O.319 268.3 24 600 24.2 10 250 10. 139.229 121.43 M10 x 70 5 ⁄8 x 41⁄4 5 40 100 136 60 130 176 460 21 533 540 24 610 25 11⁄2 38 324 14 356 359 16 406 12 12 - M20 x 90 ✛ 1 x 41⁄4 - 183⁄4 476.28 10.8 450 610 725 983 82.0 1 25.771 21.0 11⁄4 31.329 5.1 7 139.-Lbs/N-m X In.8 NOTES: The Gruvlok Flange bolt hole pattern conforms to ANSI Class 150 and Class 125 flanges.7 300 20.7 170.115 30 40 30 45 60 45 7 178 7 1⁄4 91⁄2 241 9 3⁄4 27⁄8 73 3 4 102 4 1⁄8 4 - 51⁄2 139.5. www.11 35 .8 4.6 20.3 11⁄8 28. + PN 16 uses M24 x 90 (PN) Dimensions for bolt circle PN 10 & 16 Flange.7 300 1.7 - 110 149 110 140 190 140 4.23 3 ⁄4 x 5 - 130 176 180 244 271⁄2 699 311⁄2 800 13⁄4 44 20 508 22 559 20 - 11⁄8 x 43⁄4 – 25 635.356 138.097 503.3 5.1 6.22 7.6 4.886 12.2 8.0 30.6 360 488 520 705 67.7 300 20. Ea.6 439 360 488 542 520 705 9.8 11⁄8 28.6 7.44 9. Sealing Surface Z A Max. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.9 13.D.31 ⁄8 x 41⁄4 3 100 136 130 176 231⁄2 597 261⁄2 673 11⁄2 38 16 406 18 457 16 - 1 x 41⁄4 - 211⁄4 539. Ft.341 339.9 20.875 73.0 300 20. Flange can be assembled to one side of series 7500 and 7600 valve only.7 44. (ISO) mm 5 Specified Torque § Min.7 300 20.000 355.com GL-6. see page 190.70 7.4 9.750 273.948 8.000 457.625 219.000 609.375 60. To avoid interference issues.1 6 150 165.341 46.6 M10 x 70 19 7 M16 x 70 19.7 60. 2.1 M10 x 70 3 M20 x 80 7 22.9 15.1 4.D.000 1.4 22.750 300 20. Bolts with material properties equal or greater than SAE J429 Grade 5 are acceptable.2 7 8 200 8. Max.97 ⁄8 x 23⁄4 ⁄8 x 23⁄4 ⁄8 x 23⁄4 - 30 40 45 60 131⁄2 343 161⁄2 419 1 25 85⁄8 219 10 254 8 8 (12) ⁄4 x 31⁄4 ⁄8 x 31⁄2 ⁄8 x 33⁄4 - 113⁄4 298.9 M10 x 70 3 19 3 M16 x 70 5 19. Wt. 7012 Mating Flange 2"-12" sizes 14"-24" sizes GruVLoK FIGurE 7012 FLAnGE: AnSI cLASS 150 or ISo Pn10 or Pn16 BoLt PAttErnS Nominal Size In.955 M10 x 70 3 ⁄8 x 23⁄4 M10 x 70 - 40 30 40 30 60 45 60 45 251 10 254 111⁄4 327 121⁄2 318 14 22 7 ⁄8 22 7 141 59⁄16 141 6 5⁄8 171 63⁄4 171 7 13⁄16 8 8 - M16 x 75 3 ⁄4 x 27⁄8 - 81⁄2 215.7 300 31.1 300 20.127 ⁄8 x 23⁄4 - 30 40 30 45 60 45 9 229 9 7⁄8 111⁄2 292 12 7⁄8 ⁄4 ⁄8 41⁄2 114 5 9⁄16 59⁄16 141 6 3⁄4 8 8 - ⁄8 x 23⁄4 - 71⁄2 190.181 205.8 - 1 25.996 300 20./mm Max. Working Pressure ▼ PSI/bar Max.7 76.5 48.3 13⁄8 34.1 3 4 100 51⁄2 O.9 11⁄4 31.5 23.5 220 298 250 339 15. Mating flange bolts must be at least Intermediate Strength Bolting per ASME B16. Lbs.500 88.7 27.000 508.303 170./kN Latch Bolt Latch Bolt Size* In.2 6.3 300 20. ▼ Based on use with standard wall pipe.7 300 4.7 5.12 30 40 45 60 16 406 19 483 1 25 103⁄4 273 121⁄8 308 12 12 141⁄4 362.248 419.6 2. Refer to Gruvlok Products Catalog or Anvil’s web site for more information on installing this flange.38 46.couPLInGS For GrooVEd-End PIPE Gruvlok Flanges Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.-Lbs/N-m Approx.7 19.7 94.0 2.5 52.3 2.3 6.41 2.7 300 20.1 3 88.91 ⁄8 x 23⁄4 ⁄8 x 23⁄4 - 30 40 45 60 61⁄4 159 83⁄8 213 ⁄4 ⁄4 ⁄4 23⁄8 60 37⁄16 87 4 4 ⁄8 x 23⁄4 ⁄8 x 23⁄4 - 43⁄4 120.7 1.7 ⁄4 ⁄4 110 149 140 190 4.5 62.7 5 125 61⁄2 O.1 3 76.4 18 450 18.8 M10 x 70 19 3 M16 x 70 19.4 320 439 400 542 18.4 20 500 20.9 14.1 7 ⁄8 ⁄8 298 220 298 339 250 339 4. In. 4.7 17. 12 . 4. D. if the valve is rubber faced in the area designated by the sealing surface dimensions (A Max. of the mating flange must be free from gouges. 7012 Gruvlok Flanges Gruvlok Figure 7012 Flange Mating Flange Component Gruvlok Figure 7012 Flange Mating Flange with Serrated Face A max. When mating to valves or other component equipment where the flange face has an insert. Gruvlok Flanges should not be used as anchor points for tierods across non-restrained joints. G. Contact an Anvil Representative for Di-Electric Flange connections. place the Gruvlok Flange Adapter Insert between the valve and the Gruvlok flange. B min.anvilintl.couPLInGS For GrooVEd-End PIPE fiG. C. Gruvlok Flanges are not recommended for use against formed rubber flanges. use procedure described in note 3. the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the rubber-faced flange. Grooved Pipe Flange Adapter Insert Mating Flange Rubber Surface Grooved Pipe Flange Adapter Insert Flange Gasket A. Do not use Gruvlok Flanges within 90 degrees of one another on standard fittings because the outside dimensions may cause interference. E. B. a standard full-faced flange gasket is installed against the serrated flange face and the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the standard Flange gasket. to B Min. 3. to B Min. Fig. The sealing surfaces A Max.). Applications which require a Gruvlok Flange Adapter Insert: 1. The Gruvlok Flange Adapter Insert is installed between the Gruvlok Flange sealing gasket and the mating flange or surface to provide a good sealing surface area. The use of a Gruvlok Flange Adapter Insert is required for applications against rubber faced valves or other equipment. Gruvlok Flanges are to be assembled on butterfly valves so as not to interfere with actuator or handle operation.com GL-7. 2. undulations and deformities of any type to ensure proper sealing of the gasket. 7012 Gruvlok Flange sealing gaskets require a hard flat surface for adequate sealing. When mating to a rubber-faced metal flange. When mating to a wafer valve (lug valve). F. 36 www. When mating to a serrated flange surface. com GL-7. Gruvlok Flanges have designed-in anti-rotation tines which bite into and grip the side of the pipe groove to provide a secure. HouSInG: Ductile Iron conforming to ASTM A 536. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. For Listings/Approval Details and Limitations. A specially designed gasket provides a leak-tight seal on both the pipe and the mating flange face. coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. oil-free air and many other chemical services.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. NSF-61 Certified for cold and hot water applications up through 12". * the 7013 Gruvlok adapter flange should not be used with the 78FP or 7800 check valve. or J995 Grade 2.12 37 . Grade 65-45-12. LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use for Grade “L”) www. rigid connection. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended.com or contact an Anvil® Sales Representative.anvilintl. 7013 300# Flange allows direct connection of Class 250 or Class 300 flanged components to a Gruvlok piping system. 7013 The Gruvlok Fig. Bolts and nuts are provided zinc electroplated as standard. NOT FOR USE IN PETROLEUM APPLICATIONS. NOT FOR USE IN HOT WATER OR HOT AIR. The two halves of the 2" thru 12" sizes of both Gruvlok Flanges are drawn together by a latch bolt which eases assembly on the pipe. Contact an Anvil Representative for more information.couPLInGS For GrooVEd-End PIPE Gruvlok Flanges (300# Flange) Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. air with oil vapors and vegetable and mineral oils. visit our website at www. alkalies solutions. alkalies solutions.8. oil-free air and many other chemical services. diluted acids. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. Hex nuts are zinc electroplated followed by a yellow chromate dip. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. diluted acids. Gruvlok flange adapter insert required when mating to rubber surfaces or serrated faced mating flanges. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. NOT FOR USE IN PETROLEUM APPLICATIONS. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.anvilintl. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. 7 3./mm Bolt Hole Dia.928 53.854 115.4 16.3 8.0 24.0 14.92 1 ⁄2 x 31⁄2 - 80 - 100 - 15 381 167⁄8 429 15⁄8 41 85⁄8 219 10 254 12 - 7 ⁄8 x 43⁄4 - 13 330.09 3 ⁄8 x 21⁄2 - 30 - 45 - 11 279 125⁄8 321 13⁄8 35 59⁄16 141 63⁄4 171 8 - 3 ⁄4 x 41⁄2 - 91⁄4 235.757 425.78 ⁄8 x 21⁄2 - 30 - 45 - 61⁄2 165 8 203 1 25 23⁄8 60 37⁄16 87 8 - 5 ⁄8 x 3 - 5 127.3 750 51.3 22.12 .5 22. Ea./mm In.7 43.9 11⁄4 31. Flange can be assembled to one side of series 7500 and 7600 valve. Max.66 3 ⁄8 x 21⁄2 - 30 - 45 - 71⁄2 191 91⁄8 232 1 25 27⁄8 73 4 102 8 - 3 ⁄4 x 31⁄4 ⁄4 x 31⁄2 - 57⁄8 149. undulations or deformities of any type to ensure proper sealing of the gasket./mm Approx.4 35.10 3 ⁄8 x 21⁄2 - 30 - 45 - 81⁄4 210 97⁄8 251 11⁄8 29 31⁄2 89 49⁄16 116 8 - 3 65⁄8 168.3 750 51.3 750 51.00 3 ⁄8 x 21⁄2 - 30 - 45 - 121⁄2 318 141⁄8 359 11⁄2 38 65⁄8 168 713⁄16 198 12 - 3 ⁄4 x 41⁄2 - 105⁄8 269.3 750 51. Flange cannot be assembled directly to Series 7700 butterfly valve. Wk.4 4.3 22.563 141.9 3.3 9.8 74.750 273.8 33. Lbs.500 114.D.7 7. B Min. ▼ PSI/bar Lbs.com GL-7. Bolt Circle Dia.2 7 4 100 4.625 168.2 8 200 8.1 750 51.7 11. Wt. In.7 68./kN In. 7013 Gruvlok Flanges (300# Flange) Y X Z Mating Flange GruVLoK FIGurE 7013 FLAnGE: AnSI cLASS 250 And 300 BoLt PAttErn Nominal Size In.3 19. see page 190./mm A Max.7 4./mm Sealing Surface Z In.80 1 ⁄2 x 31⁄2 - 80 - 100 - 171⁄2 445 193⁄8 492 17⁄8 48 103⁄4 273 121⁄8 308 16 - 1x5 - 151⁄4 387./mm Mating Flange Bolts Qty.875 73./mm 3 Y In.95 1 ⁄2 x 31⁄2 - 80 - 100 - 201⁄2 521 221⁄2 572 2 51 123⁄4 324 143⁄16 360 16 - 11⁄8 x 53⁄4 - 173⁄4 450.820 194.0 2.couPLInGS For GrooVEd-End PIPE fiG.216 32.9 750 51.323 14.4 6. See Installation & Assembly directions or contact your Anvil Representative Not for use with copper systems.-Lbs/N-m 2 50 2.0 18.06 3 ⁄8 x 21⁄2 - 30 - 45 - 10 254 113⁄8 289 11⁄4 32 41⁄2 114 55⁄8 143 8 - 3 ⁄4 x 33⁄4 - 77⁄8 200.625 219.869 21./mm Max.9 750 51.9 11. § – For additional Bolt Torque information. For additional details see “Coupling Data Chart Notes” on page 17.1 22.1 750 51. (ISO) mm In.4 11⁄8 28.1 7 21⁄2 65 2. ANSI Size (ANSI) in.7 18. 3 Dimensions X In.7 95.229 81. * Available in ANSI or metric bolt sizes only as indicated.9 24.7 25.500 88.375 60.2 6. In.2 7 6 150 6. ▼ Based on use with standard wall pipe. End Latch* Specified Torque § Pressure Load ▼ Bolt Size Min.6 54.0 750 51.anvilintl. 38 www. Max. In.2 1 25.5 12 300 12.2 7 5 125 5.3 22./DN(mm) O.0 ⁄4 ⁄8 ⁄8 ⁄8 ⁄8 ⁄8 5.750 323.2 7 3 80 3./Kg Ft.072 302.1 10 250 10.9 NOTES: Effective sealing area of mating flange must be free from gouges. 2. C. When mating to a serrated flange surface. When mating to a wafer valve (lug valve). a standard fullfaced flange gasket is installed against the serrated flange face and the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the standard Flange gasket. to B Min. G. Fig. Grooved Pipe Gruvlok Flange Adapter Insert Mating Flange Rubber Surface Grooved Pipe Gruvlok Flange Adapter Insert Flange Gasket A. The use of a Gruvlok Flange Adapter Insert is required for applications against rubber faced valves or other equipment. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 4. undulations and deformities of any type to ensure proper sealing of the gasket. place the Gruvlok Flange Adapter Insert between the valve and the Gruvlok flange. D. 7013 Gruvlok Flange sealing gaskets require a hard flat surface for adequate sealing.couPLInGS For GrooVEd-End PIPE Gruvlok Flanges (300# Flange) Gruvlok Figure 7013 Flange Mating Flange Component Gruvlok Figure 7013 Flange Serrated Face Mating Flange A max. The Gruvlok Flange Adapter Insert is installed between the Gruvlok Flange sealing gasket and the mating flange or surface to provide a good sealing surface area. F. 7013 . www. Gruvlok Flanges are not recommended for use against formed rubber flanges. Applications which require a Gruvlok Flange Adapter Insert: 1. Gruvlok Flanges are to be assembled on butterfly valves so as not to interfere with actuator or handle operation. Do not use Gruvlok Flanges within 90 degrees of one another on standard fittings because the outside dimensions may cause interference.anvilintl.12 39 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. The sealing surfaces A Max. Contact an Anvil Representative for Di-Electric Flange connections.).com GL-7. When mating to valves or other component equipment where the flange face has an insert. of the mating flange must be free from gouges. When mating to a rubber-faced metal flange. Gruvlok Flanges should not be used as anchor points for tierods across non-restrained joints. if the valve is rubber faced in the area designated by the sealing surface dimensions (A Max. the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the rubber-faced flange. to B Min. E. 3. B min. use procedure described in note 3. B. Refer to the Gruvlok catalog for coupling Installation is easy./mm Coupling Figure 7000 7000 7000 7000 7000 7000 7000 7001 7001 X In.com GL-7. they will not simultaneously provide for full axial expansion and angular deflection./mm Expanded Length L In./mm 50 2 2. 7000 Number of Couplings 10 10 10 5 5 5 5 5 5 4'' FIG. simply follow the Gruvlok coupling performance capabilities and material specifications.4 1 8 8. this product will contain a silicone based lubricant.8 31.0 273. X NOTE: The Gruvlok Figure 7240 Expansion Joint is also available in stainless steel for use in grooved copper systems.4 1 ⁄4 ⁄4 11⁄4 11⁄4 6 8 19 6.9 127⁄8 381 171⁄2 191⁄2 495 231⁄2 231⁄2 597 243⁄4 243⁄4 629 6.8 31.4 1 ⁄4 11⁄4 5. The expansion joints are comprised of the Gruvlok Figure 7000 or 7001 flexible couplings and precision NOTE: Expansion joint shown with shipping support.couPLInGS For GrooVEd-End PIPE fiG. 7240 Expansion Joints The Gruvlok® Figure 7240 Expansion Joints take advantage of the axial expansion capabilities of the Gruvlok flexible couplings to produce a reliable grooved end expansion joint.0 88. 7000 4'' FIG.750 323. remove the ties. To order installation and assembly instructions to install the expansion please provide the order form on the page 213.3 95⁄8 11 19 201⁄4 201⁄4 514 6.625 219./mm 1 GRUVLOK 4'' FIG.D. 7000 4'' FIG.625 168.2 1 ⁄8 31.3 45⁄8 311⁄4 183⁄4 476 514 3.1 103⁄8 264 327 131⁄4 337 445 221⁄2 572 597 233⁄4 603 629 6. Unless the desired expansion and/or contraction compensation.8 31.2 1 ⁄8 ⁄8 11⁄4 11⁄4 3 3.12 .8 11⁄4 21⁄2 65 80 100 125 150 200 250 300 2.8 31.8 31. In.3 141./mm Y In.8 31. 7000 4'' FIG. The expansion joints can be used as flexible connectors./mm Compressed Length L In./mm Coupling Movement Capability In. otherwise requested. NIPPLE COUPLING END ADAPTER GRUVLOK GRUVLOK GRUVLOK GRUVLOK Y L FIGurE 7240 PErForMAncE dAtA (IncHES) Nominal Size In.500 4.562 6.500 114.875 73.4 1 ⁄4 ⁄4 11⁄4 10 10./DN(mm) O. compressed or intermediate position to provide for for coupling and gasket used in the expansions joint. joint in the system and after installation is complete.9 4 53⁄4 63⁄4 81⁄8 30 30 311⁄4 794 794 3.4 1 11⁄4 11⁄4 12 15 6.3 31⁄2 89 100 117 149 178 200 125 146 171 206 244 279 51⁄2 762 762 762 30 311⁄4 794 3.anvilintl.4 ⁄4 40 www.2 1 4 5 57⁄8 7 171⁄2 445 483 483 6.8 31. Contact an Anvil representative for proper installation support requirements.375 60. machined grooved end pipe nipples.750 12. however. Expansion joints require pipe anchoring capable of restraining the maximum system pressure end load. 7000 Total Movement Capability In.8 31. Ties are used to custom preset the expansion joints in the The service conditions are the same as the service conditions expanded. com GL-6.11 41 .anvilintl. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.couPLInGS For GrooVEd-End PIPE Expansion Joints hanGer details Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 7240 Expansion Joint and Trough Hanger Existing Piping System trough and hanger Anchor www. 7240 Existing Piping System Existing Piping System Anchor Guide Guide Anchor vertical support Grooved Connection to Existing Piping System Guide horizontal support Grooved Connection to Existing Piping System Existing Piping System Gruvlok Fig. FPT (Fig. oil-free air and many other chemical services.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. Bolts and nuts are provided zinc electroplated as standard. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. air with oil vapor and vegetable and mineral oils. The outlet connections are available grooved (Fig.8. The outlet gasket seal is reinforced by a steel ring and is mated to a machined housing surface to assure a leak-tight outlet seal.anvilintl. 7042M). LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM(Do Not use with Grade “L”) 42 www. Figure 7075 Bull Plugs must be used on end of line run connections. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. Center ribs inside the gasket ease positioning of the pipe during installation and provide additional support to the gasket. Grade 65-45-12. Assembly of the coupling will create a gap between the pipe ends allowing the space required for the introduction of an outlet connection. diluted acids. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade “T” Nitrile (Orange color code) -20°F to 150°F (Service Temperature Range)(-29°C to 66°C) Recommended for petroleum applications. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. The gasket design is a unique pressure responsive design that provides a higher sealing force as pressure is increased. coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. 7042 Outlet Coupling is designed to join two sections of grooved end pipe and form a reducing outlet connection. HouSInG: Ductile Iron conforming to ASTM A 536.12 . StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. Figure 7074 Cast Caps may be used on Figure 7042G outlet connections. or J995 Grade 2. The outlet couplings are available for the 1 1⁄2" through 6" IPS or ISO run pipe sizes with the outlet pipe sizes ranging from 1⁄2" through 2". The outlet couplings are NOT recommended for vacuum applications. 7042F) and MPT (Fig. Hex nuts are zinc electroplated followed by a yellow chromate dip. The Figure 7074 Cast Caps are NOT recommended for use on run connections. 7042 Outlet Coupling The Gruvlok Fig./sec. NOT FOR USE IN HOT WATER OR HOT AIR. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 150°F (Service Temperature Range)(-40°C to 66°C) Recommended for water service. The gaskets are available in EPDM and Nitrile to suit a wide range of applications. Flow into the outlet connection of the Figure 7042 Outlet Couplings must not exceed 7 ft.com GL-7. 7042G). alkalies solutions. Contact an Anvil Representative for more information.BrAncH outLEtS fiG. /mm Bolt Size In.1 1./Kg ⁄2 ⁄4 — — 500 34.5 2215 9.44 13⁄16-11⁄2 30-38 43⁄16 106 61⁄2 165 31⁄4 83 29⁄16 65 — — — — 1 ⁄2 x 23⁄8 - 4.6 6.5 3246 14.9 1.5 3246 14.5 3246 14. G In./kN In./mm 3 Approx .2 15 11⁄2 40 3 — — 500 34. www. Pressure and end load ratings are for use with standard wall steel pipe.4 20 17-25 11 1 25 1 1 25 500 34.9 ⁄4 — — 500 34.5 2215 9.1 20 21⁄2 65 1 25 — — 500 34.7042G FIGurE 7042 . M/G In.anvilintl.44 13⁄16-11⁄2 30-38 43⁄16 106 61⁄2 165 31⁄4 83 27⁄16 62 — — — — 1 ⁄2 x 23⁄8 - 4.1 2.44 13⁄16-11⁄2 30-38 43⁄16 106 61⁄2 165 31⁄4 83 — — 35⁄8 92 35⁄8 92 1 ⁄2 x 23⁄8 1 5.37 19⁄16-17⁄8 40-48 63⁄16 157 87⁄8 225 35⁄8 92 — — 47⁄8 124 47⁄8 124 5 ⁄8 x 31⁄2 - 9.3 ⁄2 ⁄4 — — 500 34.6 1.0 6 150 11⁄2 40 11⁄2 40 500 34./mm FPT F In. For additional details see “Coupling Data Chart Notes” on page 17.66 15⁄8-115⁄16 41-51 81⁄8 206 111⁄4 286 311⁄16 94 43⁄4 121 6 154 6 152 5 ⁄8 x 31⁄2 - 13.5 17236 76.66 15⁄8-115⁄16 41-51 81⁄8 206 111⁄4 286 311⁄16 94 — — 6 154 6 152 5 ⁄8 x 31⁄2 - 14.BrAncH outLEtS Outlet Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.66 15⁄8-115⁄16 41-51 81⁄8 206 111⁄4 286 311⁄16 94 43⁄4 121 — — — — 5 ⁄8 x 31⁄2 - 13.5 7952 35.85 37⁄16 87 51⁄4 133 23⁄4 70 25⁄16 59 — — — — 3 ⁄8 x 21⁄8 - 3.5 4./mm 1 MPT/Grv. For a one-time field test only.5 3246 14.5 3246 14.3 — — 2 50 500 34.4 15 17-25 11 2 50 3 — — 500 34.8 2.6 1.37 19⁄16-17⁄8 40-48 63⁄16 157 87⁄8 225 35⁄8 92 311⁄16 94 — — — — 5 ⁄8 x 31⁄2 ⁄8 x 31⁄2 - 9.7 20 80 3 1 25 1 25 500 34.40 13⁄16-11⁄2 30-38 43⁄4 121 71⁄4 184 31⁄4 83 213⁄16 72 — — — — ⁄2 x 3 - 5.7042F Male IPS Outlet . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.9 4. the maximum working pressure may be increased 11⁄2 times the figure shown.5 4811 21.11 43 .5 1 25 — — 500 34.3 — — 11⁄2 40 500 34./mm MPT M In.4 ⁄4 — — 500 34./mm 3 Coupling Dimensions X In.5 17-25 ⁄2 ⁄4 — — 500 34. Each Lbs.8 — — 3 11⁄2 40 500 34.2 — — 11⁄4 32 500 34.2 6.44 13⁄16-11⁄2 30-38 43⁄16 106 61⁄2 165 31⁄4 83 29⁄16 65 — — — — 1 ⁄2 x 23⁄8 - 4.5 4.2 — — 2 50 500 34.9 2.9 2.4 2.5 4811 21.7042M Grooved Outlet .37 19⁄16-17⁄8 40-48 63⁄16 157 87⁄8 225 35⁄8 92 — — 47⁄8 124 47⁄8 124 5 ⁄8 x 31⁄2 - 9.85 11 ⁄16-1 ⁄16-1 ⁄16-1 37⁄16 87 51⁄4 133 23⁄4 70 25⁄16 59 — — — — 3 ⁄8 x 21⁄8 - 3.31 3 ⁄4-11⁄16 19-27 215⁄16 75 43⁄4 121 23⁄4 70 21⁄16 52 — — — — 3 ⁄8 x 21⁄8 - 2.5 1418 6.5 17236 76. Run Range of Pipe End Load End Separation Lbs. 7042 Female IPS Outlet.5 1418 6.37 19⁄16-17⁄8 40-48 63⁄16 157 87⁄8 225 35⁄8 92 39⁄16 91 — — — — 5 9.6 2.com GL-6./mm Grv.5 7952 35./mm Y In.2 15 3 — — 500 34.1 1./mm Working Pressure PSI/bar Max. Not for use in copper systems.40 13⁄16-11⁄2 30-38 43⁄4 121 71⁄4 184 31⁄4 83 23⁄4 70 33⁄8 86 4 102 1 ⁄2 x 3 - 6.2 2.4 2.5 1418 6.40 13⁄16-11⁄2 30-38 43⁄4 121 71⁄4 184 31⁄4 83 — — 4 102 4 102 1 ⁄2 x 3 - 6.2 4.3 — — 3 11⁄2 40 500 34.3 1.5 NOTES: Pipe ends must be prepared in accordance with Gruvlok “Roll or Cut Groove Specifications for Steel and Other IPS or ISO size Pipe”.outLEt couPLInG Nominal Pipe Size Run In./mm Z In.85 37⁄16 87 51⁄4 133 23⁄4 70 23⁄16 56 27⁄8 73 31⁄2 89 3 ⁄8 x 21⁄8 - 3. See Installation & Assembly directions on page 165.44 13⁄16-11⁄2 30-38 43⁄16 106 61⁄2 165 31⁄4 83 — — 35⁄8 92 35⁄8 92 1 ⁄2 x 23⁄8 - 5.31 ⁄4-11⁄16 19-27 215⁄16 75 43⁄4 121 23⁄4 70 21⁄16 52 — — — — ⁄8 x 21⁄8 - 2.5 4811 21.5 17236 76.2 20 1 25 1 — — 500 34.31 3 ⁄4-11⁄16 19-27 215⁄16 75 43⁄4 121 23⁄4 70 115⁄16 49 — — — — 3 ⁄8 x 21⁄8 - 2.3 6.5 7952 35.5 7952 35./DN(mm) Outlet FPT F In. Wt.5 2215 9.2 20 1 4 100 25 — — 500 34. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. u-BoLt: Cold drawn steel and zinc plated.4 material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. or J995 Grade 2.12 .8. NOT FOR USE IN PETROLEUM APPLICATIONS. 3 80 318 - 8. NSF-61 Certified for cold and hot water applications up through 12". Grade 65-45-12 coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements Contact an Anvil Representative for more information. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service.0 0. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications.0 1. 7045 Threaded Branch C.8 11/2 40 89 - 4. alkalies solutions. Value Equiv. A hole drilled or cut in the pipe to receive the locating collar of the Clamp-T is all that is required. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. HouSInG: Ductile Iron conforming to ASTM A 536. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated.BrAncH outLEtS fiG. The Gruvlok Clamp-T provides for a branch or cross connection in light wall or standard wall steel pipe. Bolts and nuts are provided zinc electroplated as standard.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B.com GL-7.6 11/4 32 76 - 2. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. The Fig.6 20 1 25 44 - 2. visit our website at www. x Thd. Hex nuts are zinc electroplated followed by a yellow chromate dip.V. FPT Branch The Gruvlok Clamp-T provides a quick and easy outlet at any location along the pipe.6 4 100 536 - 8. 7045 Clamp-T female pipe thread branch is available with NPT or ISO 7/1 connection and the Fig. oil-free air and many other chemical services.5 0. The maximum working pressure for all sizes is 500 PSI (34.0 0. oil-free air and many other chemical services. alkalies solutions.5 2.5 1. NOTE: Variable End Configurations are Possible — Thd x Thd and Gr.anvilintl.0 0. Sizes — 2" x 1/2" through 8" x 4" cLAMP-t FLoW dAtA (FrIctIonAL rESIStAncE) Branch Size Inches DN/mm 1 Fig. smooth outlet area provides for optimum flow characteristics. Pipe Length Feet Meters /2 /4 22 - 1.8 For Listings/Approval Details and Limitations. Contact an Anvil Representative for more information.5 3. Clamp-T cross connections are available in various sizes allowing greater versatility in piping design.anvilintl. air with oil vapors and vegetable and mineral oils. 7045 Clamp-T. The full. NOT FOR USE IN PETROLEUM APPLICATIONS.D. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. diluted acids.1 21/2 65 152 - 12.2 2 50 164 - 3. and the Clamp-T gasket providing a leak tight reliable seal in both positive pressure and vacuum conditions.5 bar) when assembled on standard wall steel pipe. 7046 Clamp-T has grooved-end branch connection. diluted acids. The Clamp-T housing is specially engineered to conform to the pipe O.3 15 3 25 - 2.0 2. NOT FOR USE IN HOT WATER OR HOT AIR. LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) 44 www.com or contact an Anvil® Sales Representative. 315 60.5 33⁄16 81 17⁄8 48 37⁄8 98 25⁄8 67 71⁄2 191 33⁄4 95 1 ⁄2 x 23⁄4 - 4.500 x 1.0 4 x 11⁄2 100 x 40 4.3 2 51 21⁄8 54 500 34.3 x 26.anvilintl.7 1.8 1../mm Max.315 114.375 114.2 14 3 x 11⁄4 80 x 32 3./DN(mm) O.3 11⁄2 38 15⁄8 41 500 34./mm 1 Y In. 7045 (U-Bolt) FIGurE 7045-FPt BrAncH (tABLE contInuES to nEXt PAGE) Nominal Size In.5 21⁄16 52 25⁄8 67 11⁄2 38 51⁄2 140 3 76 1 ⁄2 U-Bolt - 2.7 11⁄2 38 15⁄8 41 500 34.840 60.2 2.3 x 42. Each Ft.2 14 9 2 x 11⁄4 50 x 32 2.7 11⁄2 38 15⁄8 41 500 34.9 1.4 2 51 21⁄8 54 500 34.5 14 9 3 x 1⁄2 80 x 15 3.D.6 2.2 14 9 2 x 11⁄2 50 x 40 2.3 x 26.900 88.4 6.660 88.5 213⁄16 73 31⁄2 89 25⁄8 67 73⁄4 197 33⁄4 95 1 ⁄2 U-Bolt - 2.900 73.315 88.7 11⁄2 38 15⁄8 41 500 34.3 x 60.1 4 x 1⁄2 100 x 15 4. 7045 .660 73.5 23⁄16 55 27⁄8 73 11⁄2 38 51⁄2 140 31⁄2 89 1 ⁄2 U-Bolt - 2. 51⁄2" O.5 31⁄16 78 31⁄2 89 25⁄8 67 73⁄4 197 33⁄4 95 1 2. Not for use with copper systems.7 11⁄2 38 15⁄8 41 500 34.660 60.3 x 73.9 x 48.900 114.3 2 51 21⁄8 54 500 34.3 21⁄2 64 25⁄8 67 500 34.500 x 0.8 1.5 33⁄16 81 17⁄8 48 37⁄8 98 25⁄8 67 71⁄2 191 33⁄4 95 1 ⁄2 x 23⁄4 - 4.3 x 88.6 1.0 x 42.4 14 9 21⁄2 x 3⁄4 65 x 20 2.660 114.1 4x2 100 x 50 4.3 1.5 35⁄16 84 17⁄8 48 4 102 25⁄8 67 71⁄2 191 41⁄8 105 1 ⁄2 x 23⁄4 - 7.9 x 26.5 27⁄16 62 31⁄8 79 13⁄4 44 61⁄8 156 33⁄8 86 1 ⁄2 U-Bolt - 3./mm Hole Dimensions Min.5 29⁄16 65 3 76 21⁄8 54 7 178 33⁄4 95 1 ⁄2 U-Bolt - 2.3 11⁄2 38 15⁄8 41 500 34.5 115⁄16 51 25⁄8 67 11⁄2 38 51⁄2 140 3 76 1 ⁄2 U-Bolt - 2.2 14 4 x 11⁄4 100 x 32 4.3 11⁄2 38 15⁄8 41 500 34.500 x 2./mm U In.9 70 31⁄2 89 73 35⁄8 92 34. Run pipe size Clamp-T may be used on 3" O.3 x 33.3 14 9 4 x 3⁄4 100 x 20 4. www.500 x 0.840 88. See Installation & Assembly directions on page 166.3 x 76./mm 9 V Threaded In.1 4.050 88.9 1.500 x 2. pipe.BrAncH outLEtS Y Z Clamp-T.0 x 48./mm ▼ Max.0 1.500 x 1.D./mm W In.5 31⁄16 76 ⁄16 ⁄16 ⁄16 31⁄2 89 25⁄8 67 73⁄4 197 33⁄4 95 1 ⁄2 U-Bolt ⁄2 U-Bolt - 2. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 7045 Fig.3 2 51 21⁄8 54 500 34.com GL-6.3 2 51 21⁄8 54 500 34.0 x 21. Diameter In.3 11⁄2 38 15⁄8 41 500 34.11 45 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.5 14 9 21⁄2 x 11⁄2 65 x 40 2.996 23⁄4 70 23⁄4 27⁄8 73 27⁄8 500 34.5 500 34.500 x 2.D.4 2./mm Z In.840 73. 5" and 6" Nom.4 2 51 21⁄8 54 500 34.-Lbs/N-m Lbs.4 5.0 3x2 80 x 50 3.875 x 0. In.875 114.500 114.7 11⁄2 38 15⁄8 41 500 34.3 14 9 21⁄2 x 1 65 x 25 2.3 1.500 x 1.875 x 1. and 61⁄2" O.9 1.5 211⁄16 68 11⁄2 38 33⁄8 86 21⁄8 54 67⁄8 175 33⁄4 95 1 ⁄2 x 23⁄4 ⁄2 x 23⁄4 - 4.840 114.4 1.9 x 33.0 x 26.5 23⁄16 55 27⁄8 73 13⁄4 44 61⁄8 156 3 76 1 ⁄2 U-Bolt - 2.1 14 9 21⁄2 x 1⁄2 65 x 15 2. Diameter In.9 x 21.6 2.9 x 60.5 500 311⁄16 78 3 17⁄8 48 17⁄8 4 102 4 25⁄8 67 25⁄8 71⁄2 191 71⁄2 43⁄8 111 43⁄8 1 ⁄2 x 23⁄4 ⁄2 x 23⁄4 5.3 14 9 21⁄2 x 11⁄4 65 x 32 2.315 73. Min.3 14 9 4x1 100 x 25 4.2 14 9 3x1 80 x 25 3.5 27⁄16 62 31⁄8 79 13⁄4 44 61⁄8 156 33⁄8 86 1 ⁄2 U-Bolt - 3. 4.7 11⁄2 38 15⁄8 41 500 34.5 27⁄16 62 27⁄8 73 13⁄4 44 51⁄2 140 3 76 1 ⁄2 U-Bolt - 3.5 76 31⁄4 83 48 17⁄8 48 102 41⁄4 108 67 25⁄8 67 191 71⁄2 191 111 51⁄4 133 1 ⁄2 x 31⁄2 - 80 100 2./mm Bolt Size In.375 x 1.3 x 48. (Additional larger sizes on next page.4 1.375 x 0.375 88.5 211⁄16 68 11⁄2 38 9 33⁄8 86 21⁄8 54 67⁄8 175 41⁄8 105 1 4.050 114.5 1. FPT Branch V W T Fig.0 x 33.3 x 42.7 11⁄2 38 15⁄8 41 500 34.D.375 x 1.500 x 1.2 14 9 3 x 3⁄4 80 x 20 3.050 60.7 3.050 73.500 x 1.875 x 1.5 2.500 x 1.5 23⁄16 55 27⁄8 73 11⁄2 38 7 178 31⁄2 89 1 ⁄2 U-Bolt - 2.0 14 9 12 2 x 3⁄4 50 x 20 2.7 1.7 1.7 1.3 x 21.4 1. Working Pressure PSI/bar Clamp-T Dimensions T In.500 x 1.) ▼ Based on use with standard wall pipe.0 4.7 11⁄2 38 15⁄8 41 500 34.3 x 48.3 x 21.9 NOTE: 21⁄2".5 23⁄16 56 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 25⁄8 67 ⁄2 51⁄2 140 3 76 ⁄2 U-Bolt - 30 30 30 30 30 30 30 30 30 30 30 30 30 80 80 80 30 30 30 80 80 80 80 80 40 40 40 40 40 40 40 40 40 40 40 40 40 100 100 100 40 40 40 100 100 100 100 100 2.3 x 33.5 211⁄16 68 11⁄2 38 33⁄8 86 21⁄8 54 67⁄8 175 33⁄4 95 3.375 x 1.2 1 100 x 80 4x3 100 x 80 114.9 x 42.5 27⁄16 62 3 76 21⁄8 54 7 178 33⁄4 95 1 ⁄2 U-Bolt 1 2.500 x 2.5 25⁄16 59 27⁄8 73 13⁄4 44 51⁄2 140 3 76 1 ⁄2 U-Bolt - 2.3 21⁄2 64 25⁄8 67 500 34./Kg 2 x 1⁄2 50 x 15 2. Wt. see page 190. § – For additional Bolt Torque information.5 3 x 11⁄2 80 x 40 3.875 x 1.875 x 1.900 60.4 2 51 21⁄8 54 500 34./mm 1 Specified Torque § Approx .500 x 3.0 14 9 2x1 50 x 25 2.500 x 1.375 x 1.5 25⁄16 59 3 76 21⁄8 54 7 178 33⁄4 95 1 ⁄2 U-Bolt ⁄2x 23⁄4 - 2.4 2 51 21⁄8 54 500 34.5 4 x 21⁄2 100 x 65 4 x 3 O.5 2. Max.D. Not for use with copper systems.625 x 1.1 x 73.12 . § – For additional Bolt Torque information.0 5 125 x 80 5x3 125 x 80 141.0 13./DN(mm) O.625 x 1.5 311⁄16 94 17⁄8 48 43⁄8 111 31⁄4 83 91⁄8 232 33⁄4 95 5 ⁄8 x 31⁄4 - 5.996 23⁄4 70 23⁄4 27⁄8 73 27⁄8 500 34. 5" and 6" Nom. 6.3 2 51 21⁄8 54 500 34.3 NOTE: 21⁄2".500 219.0 5.625 x 2.5 311⁄16 94 17⁄8 48 43⁄8 111 31⁄4 83 91⁄8 232 33⁄4 95 ⁄8 x 31⁄4 - 100 100 100 100 130 130 130 130 130 180 5.625 x 2./mm In.com GL-7.3 41⁄2 114 45⁄8 117 500 34.875 168./mm ▼ Max.3 2 51 21⁄8 54 500 34.8 9.3 x 76.3 x 88./mm Z In.625 x 2.1 x 114.0 6.5 6 x 21⁄2 150 x 65 6 x 3 O.1 x 70.5 6x2 150 x 50 6.9 70 31⁄2 89 73 35⁄8 92 34.996 23⁄4 70 23⁄4 27⁄8 73 27⁄8 500 34. (Additional smaller sizes on previous page.5 6 x 11⁄2 150 x 40 6.4 5 150 x 80 6x3 150 x 80 168.6 4.5 43⁄16 106 2 51 47⁄8 124 37⁄8 98 101⁄8 257 33⁄4 95 ⁄8 x 41⁄4 - 7. 46 www.5 53⁄8 137 21⁄4 57 61⁄2 165 5 127 123⁄4 324 61⁄2 165 3 ⁄4 x 41⁄2 - 16. Max.1 x 88.1 5.750 219./mm Hole Dimensions Min.563 x 2.625 x 2.5 43⁄8 111 2 51 51⁄2 140 37⁄8 98 101⁄8 257 61⁄2 165 ⁄8 x 41⁄4 - 10.4 2 51 21⁄8 54 500 34. Diameter Max.5 5x2 125 x 50 5.996 23⁄4 70 23⁄4 27⁄8 73 27⁄8 500 34.625 x 3.0 11.1 8. 7045 Fig.3 x 42.9 70 31⁄2 89 73 35⁄8 92 34. In.7 3./mm W In.563 x 1.3 5.563 x 2./mm V Threaded In. Working Pressure PSI/bar Clamp-T Dimensions T In.0 21⁄2 64 25⁄8 67 500 34./Kg 5 x 11⁄4 125 x 32 5.5 500 34.3 x 48.7 2.2 7.660 141.D./mm Bolt Size In.D. Diameter In. 7045 (U-Bolt) FIGurE 7045-FPt BrAncH (contInuEd FroM PrEVIouS PAGE) Nominal Size In.5 53⁄16 132 21⁄4 57 57⁄8 149 5 127 123⁄4 324 41⁄8 105 3 ⁄4 x 41⁄4 - 11.D.5 500 313⁄16 97 33⁄4 17⁄8 48 17⁄8 43⁄4 121 43⁄4 31⁄4 83 31⁄4 91⁄8 232 91⁄8 43⁄8 111 43⁄8 5 ⁄8 x 31⁄4 ⁄8 x 31⁄4 7.-Lbs/N-m Lbs.D.3 x 73.3 x 76.8 8x2 200 x 50 8.3 21⁄2 64 25⁄8 67 500 34.9 70 31⁄2 89 73 35⁄8 92 34.8 3.3 x 60.anvilintl.1 x 76.3 x 88.4 5 x 11⁄2 125 x 40 5. 7045 Y Z Clamp-T./mm U In.500 168./mm 5 Specified Torque § Approx .625 x 2.5 43⁄16 106 2 51 47⁄8 124 37⁄8 98 101⁄8 257 33⁄4 95 5 ⁄8 x 41⁄4 - 7.625 x 3. Min.5 313⁄16 97 17⁄8 48 41⁄2 114 31⁄4 83 91⁄8 232 41⁄8 105 5 ⁄8 x 31⁄4 - 5.4 2 51 21⁄8 54 500 34.5 2.625 x 4.625 x 2.660 168. 8.3 x 114.3 x 48.4 2.5 43⁄16 106 2 51 47⁄8 124 37⁄8 98 101⁄8 257 41⁄8 105 5 ⁄8 x 41⁄4 - 7.8 8.5 500 34.3 x 60.900 141.0 3.6 5 x 21⁄2 125 x 65 5 x 3 O.8 3. See Installation & Assembly directions on page 166.5 4.D.2 7.3 21⁄2 64 25⁄8 67 500 34.5 500 55⁄16 134 51⁄4 21⁄4 57 21⁄4 61⁄4 159 61⁄4 5 127 5 123⁄4 324 123⁄4 43⁄8 111 43⁄8 3 ⁄4 x 41⁄2 ⁄4 x 41⁄2 11.500 168.1 8 x 21⁄2 200 x 65 8 x 3 O.625 x 4.9 8x4 200 x 100 8. 51⁄2" O. 5.9 6 x 11⁄4 150 x 32 6.1 6.0 8.563 x 1.3 41⁄2 114 45⁄8 117 500 34. FPT Branch V W T Fig./mm Y In.) ▼ Based on use with standard wall pipe. Run pipe size Clamp-T may be used on 3" O.BrAncH outLEtS fiG.375 168.D.375 141. see page 190.5 500 34.5 500 43⁄16 106 41⁄8 2 51 2 51⁄8 130 51⁄8 37⁄8 98 37⁄8 101⁄8 257 101⁄8 43⁄8 111 43⁄8 5 ⁄8 x 41⁄4 ⁄8 x 41⁄4 8.563 x 3.500 141.500 219.4 3. Each Ft.5 95 4 102 48 17⁄8 48 121 5 127 83 31⁄4 83 232 91⁄8 232 111 51⁄4 133 5 ⁄8 x 31⁄4 5 100 100 100 100 100 100 130 130 130 130 130 130 3.3 x 73.4 6x4 150 x 100 6.5 105 43⁄8 111 51 2 51 130 53⁄8 137 98 37⁄8 98 257 101⁄8 257 111 51⁄4 133 5 ⁄8 x 41⁄4 5 100 100 130 130 130 130 130 180 180 180 3. pipe.1 3 200 x 80 8x3 200 x 80 219.3 x 42.2 8..D.0 5.563 x 2.8 3.875 219. and 61⁄2" O. Wt.5 133 53⁄8 137 57 21⁄4 57 159 63⁄8 162 127 5 127 324 123⁄4 324 111 51⁄4 133 3 ⁄4 x 41⁄2 - 130 130 180 180 5.1 5.900 168.875 141. oil-free air and many other chemical services. NOT FOR USE IN HOT WATER OR HOT AIR.5 1.0 1. diluted acids. 7046 . 7046 Grooved Branch C.1 40 2 50 4. LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) www. smooth outlet area provides for optimum flow characteristics. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. NSF-61 Certified for cold and hot water applications up through 12".1 Clamp-T cross connections are available in most sizes allowing greater versatility in piping design. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.1 3 80 9. HouSInG: Ductile Iron conforming to ASTM A 536. material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. Pipe Length Ft.5 32 1 /2 1 3.com or contact an Anvil® Sales Representative.5 1. visit our website at www.8. Hex nuts are zinc electroplated followed by a yellow chromate dip. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service.BrAncH outLEtS Clamp-T. A hole drilled or cut in the pipe to receive the locating collar of the Clamp-T is all that is required.0 2. diluted acids.4 21/2 65 7./Meters 1 /4 1 5.com GL-7. Value Equiv. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. air with oil vapors and vegetable and mineral oils. alkalies solutions. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. StAInLESS StEEL BoLtS & nutS: Stainless Steel Bolts and Nuts are also available. Bolts and nuts are provided zinc electroplated as standard.5 bar) when assembled on standard wall steel pipe. The full. cLAMP-t FLoW dAtA (FrIctIonAL rESIStAncE) Branch Size In.D. The Clamp-T housing is specially engineered to conform to the pipe O.anvilintl. The maximum working pressure for all sizes is 500 PSI (34. or J995 Grade 2.0 2.anvilintl. oil-free air and many other chemical services. alkalies solutions. NOT FOR USE IN PETROLEUM APPLICATIONS. u-BoLt: Cold drawn steel and zinc plated. Grooved Branch The Gruvlok Clamp-T provides a quick and easy outlet at any location along the pipe. The Gruvlok Clamp-T provides for a branch or cross connection in light wall or standard wall steel pipe. Contact an Anvil Representative for more information. Grade 65-45-12 coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative for more information./DN/mm Fig. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110.4 95 148 205 294 571 5.5 2. NOT FOR USE IN PETROLEUM APPLICATIONS.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B.12 47 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. For Listings/Approval Details and Limitations.9 4 100 7. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.V. and the Clamp-T gasket providing a leak-tight reliable seal in both positive pressure and vacuum conditions. 500 168./mm W In.875 5. 7046 Fig.3 x 48.4 4./mm 9 V Grooved In.D.0 x 42.900 5. § – For additional Bolt Torque information.4 73.3 51 51 51 51 2 21⁄8 54 1 34. Run pipe size Clamp-T may be used on 3" O.1 2 ⁄2 x 1 ⁄2 65 x 40 80 x 32 80 x 40 80 x 50 100 x 32 100 x 40 100 x 50 100 x 65 4 x 3 O.2 7.5 1.3 88.625 x 2. 2.2 M20 x 110 3 130 130 175 180 180 245 11.3 168.6 5.11 .5 34.5 500 102 4 102 108 108 108 108 117 127 127 130 51⁄8 191 71⁄2 191 232 232 232 232 232 111 51⁄4 133 1 80 80 100 100 100 100 100 100 100 100 100 100 130 130 130 130 130 130 130 130 5 x 11⁄4 5 x 11⁄2 5x2 5.3 x 42.563 x 1.D.660 5.5 34.3 41⁄2 45⁄8 M20 x 110 NOTES: 21⁄2".6 3. Diameter In.9 2.0 2.3 2 2 2 2 ⁄8 54 54 54 67 14 38 38 38 48 48 48 3 ⁄8 79 89 89 89 1 ⁄4 44 54 54 54 67 67 67 3 ⁄2 89 95 95 1 ⁄2 U-Bolt ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 ⁄2 x 31⁄2 * * ⁄2 x 23⁄4 3.3 x 60.375 5.5 34.8 5.3 x 76.500 x 2.500 x 1.875 x 1.3 3.375 6.900 3.4 1. Not for use with copper systems.900 4. ▼ Based on use with standard wall pipe. 30 30 80 80 80 80 80 80 80 80 Max.5 2.660 114./mm Z In.660 3. Wt.D.0 2.625 x 3.3 219.1 3 x 11⁄4 3 x 11⁄2 3x2 21⁄8 21⁄8 25⁄8 21⁄8 54 54 67 11⁄2 11⁄2 11⁄2 17⁄8 17⁄8 17⁄8 17⁄8 48 17⁄8 48 48 48 48 48 48 51 51 51 2 48 17⁄8 31⁄2 31⁄2 31⁄2 102 102 102 102 4 21⁄8 21⁄8 21⁄8 25⁄8 25⁄8 25⁄8 25⁄8 67 25⁄8 67 83 83 83 83 83 98 98 67 25⁄8 67⁄8 67⁄8 67⁄8 71⁄2 71⁄2 71⁄2 71⁄2 33⁄4 33⁄4 105 1 1 21⁄2 64 51 51 41⁄8 33⁄4 95 95 1 4 x 11⁄4 4 x 11⁄2 4x2 2 2 4 4 4 4 1 4.5 34.3 5.4 7. pipe.3 x 73.9 168.625 x 2.625 x 4.625 x 2.5 34.3 x 60. 5" and 6" Nom.500 114.3 4.3 x 88.5 34./mm Y In.0 3.5 34.9 141.4 114.5 2.2 3.3 114.3 x 60.875 8.625 x 3.5 34.500 6.5 500 34.900 6. 7046 Clamp-T. In. Diameter Max.D./mm Hole Dimensions Min. 51⁄2" O.563 x 1.500 x 2.4 4.5 500 500 500 500 500 500 500 500 500 500 14 9 ⁄16 ⁄16 31⁄8 79 1 13⁄4 44 3 156 156 175 175 175 191 191 191 191 71⁄2 61⁄8 6 ⁄8 1 31⁄2 89 1 ⁄2 U-Bolt - 3.0 2.9 41⁄2 21⁄2 64 70 89 45⁄8 25⁄8 67 73 92 500 500 500 500 500 2 51⁄4 61⁄8 61⁄8 61⁄8 61⁄4 37⁄8 98 127 127 127 127 101⁄8 257 61⁄2 41⁄4 43⁄8 51⁄4 61⁄2 5 ⁄8 x 41⁄4 * 10.875 114.5 34.0 4.900 3.3 114.3 x 88.3 x 73.5 2.D.5 34.625 x 1.6 5.6 2.625 x 4.5 2.6 4.anvilintl.3 141.5 34.0 x 48.5 1.1 x 73. • Cannot be used in cross configuration.1 4.3 x 48.1 x 88.3 219.5 16.500 8.5 34. 40 40 100 100 100 100 100 100 100 100 Approx. 7046 (U-Bolt) FIGurE 7046-Gr BrAncH Nominal Size In./DN(mm) O.3 5.6 3.500 x 2.3 x 42. see page 190.8 7.5 2.5 34.2 1.2 7./mm Bolt Size In.4 8.4 141.9 x 42.500 x 1. and 61⁄2" O.com GL-6./mm In.9 168. See Installation & Assembly directions on page 166.875 168.996 2 2 21⁄8 21⁄8 25⁄8 27⁄8 35⁄8 21⁄8 25⁄8 27⁄8 73 35⁄8 92 117 73 27⁄8 500 500 500 500 500 500 500 500 17⁄8 17⁄8 17⁄8 17⁄8 17⁄8 2 2 2 41⁄4 41⁄4 41⁄4 41⁄4 45⁄8 5 5 31⁄4 31⁄4 31⁄4 31⁄4 31⁄4 37⁄8 37⁄8 37⁄8 98 37⁄8 98 98 37⁄8 91⁄8 91⁄8 91⁄8 91⁄8 91⁄8 33⁄4 95 95 1 ⁄2 x 23⁄4 ⁄8 x 31⁄4 ⁄8 x 31⁄4 ⁄8 x 31⁄4 ⁄8 x 31⁄4 ⁄8 x 41⁄4 ⁄8 x 41⁄4 ⁄8 x 41⁄4 * ⁄8 x 41⁄4 * * ⁄8 x 41⁄4 5. Each Lbs.BrAncH outLEtS fiG.6 3.3 x 73.375 4.660 73.500 x 1.5 5./Kg Ft.6 33⁄4 105 111 133 5 21⁄2 64 70 89 51 41⁄8 43⁄8 51⁄4 33⁄4 95 5 5 x 21⁄2 5x3 23⁄4 31⁄2 2 5 5 6 x 11⁄2 6x2 101⁄8 257 257 5 21⁄2 64 101⁄8 101⁄8 257 101⁄8 257 257 101⁄8 105 111 43⁄8 41⁄8 43⁄8 5 6 x 21⁄2 23⁄4 70 31⁄2 89 114 70 23⁄4 51⁄8 5 5 150 x 80 6x3 150 x 80 150 x 100 200 x 50 200 x 65 200 x 80 200 x 100 34.500 219.4 88.3 x 114.3 141. Grooved Branch Y Z V W Fig.6 4.5 34.5 34.5 34.5 2.7 8.5 51 2 51 51 130 51⁄8 130 133 156 156 156 159 111 51⁄4 133 165 108 111 133 165 5 100 100 130 130 175 175 130 130 180 180 245 245 6x4 8x2 6.1 7.5 34.4 4./mm 1 Specified Torque § Min.4 3.563 x 2.625 x 2.5 500 34.1 6./mm ▼ Max.500 x 2.8 7.6 5.9 x 48.4 4.0 6.0 219.563 x 3.0 141.563 x 2.3 x 76.625 x 2.3 x 88.-Lbs/N-m 21⁄2 x 11⁄4• 65 x 32 1 1 2.5 34.1 x 60. Working Pressure PSI/bar Clamp-T Dimensions U In..5 34.3 88.3 21⁄4 57 57 57 5 5 5 5 123⁄4 324 324 324 3 ⁄4 x 41⁄2 - 10.375 4.375 8.5 34.3 x 48. 48 www.0 21⁄2 64 41⁄8 43⁄8 1 4 x 21⁄2 23⁄4 70 31⁄2 89 51 51 70 23⁄4 1 1 100 x 80 4x3 100 x 80 125 x 32 125 x 40 125 x 50 125 x 65 125 x 80 150 x 40 150 x 50 150 x 65 6 x 3 O.996 21⁄8 25⁄8 27⁄8 73 35⁄8 92 54 54 67 73 92 54 67 73 27⁄8 33⁄4 105 111 43⁄8 1 4.5 34. 34.500 x 3.9 x 60.D.7 8 x 21⁄2 8x3 8x4 23⁄4 31⁄2 114 27⁄8 35⁄8 117 21⁄4 21⁄4 21⁄4 57 123⁄4 123⁄4 123⁄4 324 3 M20 x 110 3 ⁄4 x 41⁄2 ⁄4 x 41⁄2 ⁄4 x 41⁄2 10.500 x 1.500 168.875 x 1.1 x 114. StAInLESS StEEL BoLtS & nutS: Stainless steel bolts and nuts are also available. Z V V V T V V For Listings/Approval Details and Limitations. Fig. oil-free air and many other chemical services. coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative for more information. 7049 . 7045 Clamp-T female pipe thread branch is available with NPT or ISO 7/1 connection and the Fig. Grade 32510. The Fig. NOT FOR USE IN PETROLEUM APPLICATIONS. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110.anvilintl. oil-free air and many other chemical services. 7049 The Gruvlok Clamp-T provides a branch or cross connection in light wall or standard wall steel pipe. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 7047.anvilintl. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. Grade 65-45-12 or Malleable Iron conforming to ASTM A 47. 7048 & fiG.BrAncH outLEtS Clamp-T.Groove x Groove Fig.com GL-7. diluted acids. NOT FOR USE IN PETROLEUM APPLICATIONS. NOT FOR USE IN HOT WATER OR HOT AIR. Hex nuts are zinc electroplated followed by a yellow chromate dip. alkalies solutions. Clamp-T cross connections are available allowing greater versatility in piping design. 7048 Y Z Fig. HouSInG: Ductile Iron conforming to ASTM A 536. or J995 Grade 2. 7049 Y NOTE: 2 1⁄2" x 1 1/4" Figure 7046 cannot be used in cross configuration. alkalies solutions. www. visit our website at www.Thread x Thread Fig. 7048 . diluted acids. 7046 Clamp-T has grooved-end branch connection. 7047 Y V Z Fig. air with oil vapors and vegetable and mineral oils. 7047 . Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. fiG. MEtrIc BoLtS & HEAVY HEX nutS: Heat treated. Cross Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Fig.Groove x Thread material specifications AnSI BoLtS & HEAVY HEX nutS: Heat treated. Contact an Anvil Representative for more information.12 49 .com or contact an Anvil® Sales Representative. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended. Bolts and nuts are provided zinc electroplated as standard. LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) Not for use in copper systems.8. NSF-61 Certified for cold and hot water applications up through 12". 4 32 x 15 30 32 53 89 56 35 11⁄4 x 3⁄4 32 x 20 1.4 2 x 1⁄2 50 x 15 2.840 60. NOT FOR USE IN PETROLEUM APPLICATIONS.anvilintl../mm Hole Diameter Min.com GL-7. The branch outlet provides an economical. visit our website at www./N-m 1 ⁄4 x ⁄2 1 1 1. 27 - Max. alkalies solutions.9 0. oil-free air and many chemical services.7 13⁄16 30 11⁄4 32 211⁄16 69 43⁄8 111 27⁄32 56 2 51 27 - 33 - 0.8 0.0 0. In.4 11⁄2 x 3⁄4 40 x 20 1.3 x 33./mm Specified Torque § Approx. Dia.660 x 1. § – For additional Bolt Torque information. and easy outlet at any location along a pipe.8 0. see page 190. See Installation & Assembly directions on page 167. LuBrIcAtIon: Standard Gruvlok Gruvlok XtremeTM Nominal Size In.12 . Specially engineered to conform to the pipe O.315 73. diluted acids.7 13⁄16 30 11⁄4 32 21⁄16 53 31⁄2 89 27⁄32 56 13⁄8 35 27 - 33 - 0.3 x 21. Ductile iron housings with Grade E gasket and carbon steel U-bolt (3⁄8" dia./mm C In. Ductile iron housings is available black.com or contact an Anvil® Sales Representative.0 x 26.7 1 ⁄16 3 1 ⁄4 1 2 ⁄8 5 3 ⁄8 7 2 ⁄32 7 1 ⁄4 3 27 - 33 - 0.3 x 33.900 x 0. In.4 50 x 20 30 32 64 98 56 42 2x1 50 x 25 2.D.) with flanged nuts. u-BoLt: Plated U-bolt conforming to ASTM A 307 with plated hex nuts conforming to ASTM A 563.050 48.375 x 0.7 1 ⁄16 3 1 ⁄4 1 2 ⁄2 1 3 ⁄8 7 2 ⁄32 7 1 ⁄8 5 27 - 33 - 0.050 42.7 13⁄16 30 11⁄4 32 213⁄16 72 43⁄8 111 27⁄32 56 21⁄8 54 27 - 33 - 1.4 11⁄2 x 1 40 x 25 1.anvilintl.8 0.4 21⁄2 x 3⁄4 65 x 20 2. 7044 Branch Outlet The Gruvlok Fig.BrAncH outLEtS fiG.9 0.375 x 1.0 x 21.3 13⁄16 30 11⁄4 32 25⁄32 55 31⁄2 89 27⁄32 56 13⁄8 35 27 - 33 - 0.5 Not for use in copper systems. saddle up and fasten it with the U-bolt.9 0.7 13⁄16 30 11⁄4 32 23⁄16 56 31⁄2 89 27⁄32 56 11⁄2 38 27 - 33 - 0.9 0. The maximum working pressure for all sizes is 175 PSI (12.3 13⁄16 30 11⁄4 32 21⁄2 64 37⁄8 98 27⁄32 56 15⁄8 42 27 - 33 - 0.050 73. the Fig.3 1 ⁄16 3 1 ⁄4 1 2 ⁄16 1 3 ⁄2 1 2 ⁄32 7 1 ⁄8 3 0.8 0. B In.4 11⁄4 x 1 32 x 25 1. 33 - Wt.8 0.4 30 32 67 98 56 45 21⁄2 x 1⁄2 65 x 15 2.050 60.900 x 1.840 48. Each Lbs.3 13⁄16 30 11⁄4 32 211⁄16 69 43⁄8 111 27⁄32 56 2 51 27 - 33 - 0.840 42.7 13⁄16 30 11⁄4 32 25⁄32 55 31⁄2 89 27⁄32 56 13⁄8 35 27 - 33 - 0.315 60.875 x 1./Kg Ft.3 x 26./mm Dimensions A In.4 11⁄2 x 1⁄2 40 x 15 1. quick.875 x 0. HouSInG: Ductile Iron conforming to ASTM A 536.8 0. 50 www.D.375 x 1.3 x 21.8 0.660 x 1./mm Max.4 21⁄2 x 1 65 x 25 2.315 42. 7044 provides a leak tight reliable seal in both positive pressure and vacuum conditions./mm Take-out T In. material specifications GASKEtS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 150°F (Service Temperature Range) (-40°C to 66°C) Recommended for water service.315 48.4 2 x ⁄4 3 2.4 x 33.1 bar). Grade 65-45-12. For Listings/Approval Details and Limitations. Just cut a hole.875 x 1.900 x 1.0 x 33.4 x 26.840 73. 7044 Branch Outlet is for direct connection of sprinkler heads and drop nipples. Dia. In.660 x 0.-Lbs.3 x 26./DN(mm) FIGurE 7044 BrAncH outLEt O./mm Min.4 x 21.7 13⁄16 30 11⁄4 32 29⁄32 58 31⁄2 89 27⁄32 56 11⁄2 38 27 - 33 - 0. 6 25.9 9. www. Gruvlok Fittings are identified by either the Nominal size in inches or the Pipe O.3 1.1 6 150 200 250 300 350 400 450 500 2 ⁄2 8 8.5 8.D.1 9.236 5.6 6.0 0. the branch value of 3" is 12. 80 41⁄4 O.D.133 0.0 0.7 8.1 3 FIttInG SIZE Nominal Size In.4 3.3 4.0 0.4 4.0 34.7 5. visit our website at www.3 219. For Listings/Approval Details and Limitations.7 20.D.1 3 80 65 41⁄4 O.0 7.000 20. Use the Fitting Size Table to convert nominal pipe size to corresponding pipe O.4 3.6 9.5 1.D.5 9.6 2.259 5.3 2.5 9.7 20.1 3. In.3 113.0 6. forged steel or fabricated steel.1 5.8 3.000 20.216 5.375 0.0 2.6 5.4 3. In./m 45° Ft.3 8.0 4 O.0 6.375 wall.5 9.1 2.9 7.2 508.000 18.875 76.1 0.237 6.7 31.1 2.6 0. Grade 65-45-12 Malleable iron conforming to ASTM A 47 FABrIcAtEd FIttInGS: 1-6" Carbon steel.0 457. 108.280 0.6 22.3 11⁄4 32 40 50 65 3 O.GruVLoK FIttInGS Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.1 34.4 4.9).7 2.1 10.7 8.3 4.3 6.6 406.1 1.2 0.1 10. 600 609.3 41.6 3. 7001 Gruvlok coupling.7 2.8 7./mm 133.4 48.220 5.280 7.500 88. conforming to ASTM A 53.0 61⁄2 O.000 16.0 64.0 2. For example: for 6" x 6" x 3" tee.000 609.9 4.0 10.9 87.1 3.D.5 8./m Branch Ft.1 0.322 0.3 2.4 0.5 28.3 33.3 5.6 4.2 7.1 6.3 5.750 12.0 4 133.6 139.0 6.9 16.375 0.248 5.1 20.5 0.1 7.1 3.3 2.500 114.3 1.3 6.3 1./mm Elbow 90° Ft.com GL-7.0 165.2 97.248 6.000 16.3 20.1 13.3 4.500 11⁄2 2 1 159.4 355.4 23.0 6.8 2.3 16.8 ft (3.7 139.5 9. In.3 60.8 4.0 1. Schedule 30.8 6. Pressure ratings of Gruvlok standard fittings conform to those of Fig.900 2.0 323.0 8.197 3./mm Pipe Wall Thickness In.500 108.280 0.0 22.750 14.140 0.000 101.9 16. Grade B coAtInGS: Rust inhibiting paint – Color: ORANGE (standard) Hot Dipped Zinc Galvanized conforming to ASTM A 153 (optional) Other Colors Available (IE: RAL3000 and RAL9000) 11⁄4 11⁄2 40 50 32 25 1 1.4 1./m Tee cASt FIttInGS: Ductile iron conforming to ASTM A 536.0 4.7 8.2 0.0 0.258 6.9 355.2 33. 125 6 ⁄4 O.0 108.500 20 24 133.D.8 7.145 0.500 114.375 0.0 3./DN(mm) material specifications Run Ft.D.7 3.8 0.8 6. FLoW dAtA – FrIctIonAL rESIStAncE (EXPrESSEd AS EQuIVALEnt StrAIGHt PIPE) Nom.1 25 1 1.0 139.9 32./DN(mm) O.12 51 . 165.750 14.7 The Fitting Size Chart is used to determine the O.3 5.1 3.7 3.6 0.900 2.375 2.0 1. Size In.5 7.2 5.1 1.8 50. These fittings are designed to provide minimum pressure drop and uniform strength.750 12. in/mm.0 2.9 1.1 273.0 22.2 1.anvilintl.625 168.0 6.000 24.4 0.9 6.1 4.375 9.0 165.9 26.1 0.3 12.6 9.4 457.0 165.0 1.154 0.6 9.6 508. conforming to ASTM A 53.1 5.0 2.625 10.D.8 5.0 7.6 10.9 3.D.4 1. 0.375 0.D. conforming to ASTM A 53.4 31.5 2 65 3 O.D. Schedule 40.3 0.7 3./mm Nominal Size In.3 1. 76.0 4.9 10 12 14 16 18 20 24 12 14 16 18 31⁄2 4.0 4.4 1.7 5 159.4 10.7 2.4 3.7 8.7 2.D.9 273.D.8 8.5 19.250 100 51⁄4 O.3 42.com or contact an Anvil® Sales Representative.236 88.2 0.1 3.315 33./m O.2 1.6 6.2 38.6 1.375 2.3 3.7 20.2 1. 100 51⁄4 O. Depending on styles and size.4 1.7 0.3 6. Gruvlok fittings are provided in various materials including malleable iron.5 9.3 5.D.5 0.0 2. Not for use in copper systems.5 5. 159.3 2.0 139.2 73.1 6 150 200 250 300 350 400 450 500 600 7.000 24.660 1. 51⁄2 O.1 10. 5 5.0 61⁄2 O.2 4.203 5.3 16.1 4.2 406.365 0.1 3.D.500 133.3 6.2 25.9 4. 1.7 26.6 323.3 48.7 24.4 2.3 10.1 6.4 29.5 9.8 40.4 24.1 3.7 0.996 60.6 15.996 140 61⁄4 O.000 18./DN(mm) 108.D.7 2.4 21.0 0.4 42.0 1.0 51⁄2 O.563 159.D. For the reducing tee and branches.6 2. 1 21⁄2 76.1 168.8 0.anvilintl.000 8 10 76.7 10.2 1.1 13.625 10.625 8.D. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok fittinGs for Grooved-end pipe Gruvlok fittings are available through 24" nominal pipe size in a variety of styles.4 0.375 0.1 25.0 17.0 10.4 2. Grade B 8-12" Carbon steel.5 0.8 1.1 6.500 141. use the value that is corresponding to the branch size. Grade B 14-24" Carbon steel.563 141.0 8.6 2.4 5.8 6.0 6.7 2.2 4.660 1.5 8.315 1. of the pipe that the fittings is to be used with.2 12.250 73.0 1.9 11.259 6.4 12.875 73.1 219. ductile iron. 875 73.7 29.1 3 80 90 41⁄4 O.75 12.0 11.000 24.D. 1.500 73.1 9.996 23⁄4 C 23⁄4 C 31⁄4 C 3 ⁄4 C 3 1.1 66.0 133 51⁄2 C 140 6C 1 4.D.660 1.2 8 8.7 For Listings/Approval Details and Limitations.3 5.2 11⁄4 32 40 50 1.315 33.536 10.7 53.5 3.0 51⁄2 6 7 300 323.0 5./mm Center Approx.875 73.0 344.259 6.8 2 15⁄8 0.7 0./mm Lbs.000 20.4 0.2 508. 1 165.6 0.38 31/8 79.1 10.D.625 10. 31⁄4 C 125 61⁄4 O.3 60.9 24.D.563 6.7 2.9 51⁄2 O.134 2. In.3 2.907 2. 7050 90° Elbow* fiG. Cast Fabricated FIGurE 7050 90° ELBoW* Nominal Size In.5 1.D./mm Lbs.D.3 13⁄4 C 44 44 44 51 0.8 21⁄4 25⁄8 0.6 13. contact an Anvil Representative for more information.8 34.0 4.1 40.000 101.6 152 6 ⁄2 C 6.5 11⁄4 32 40 50 65 3 O.500 114.1 323.3 60.D. 1 6 ⁄2 O.750 14.900 2.3 280.6 1.0 13.0 8 8. 76.9 31⁄4 83 44 44 48 51 0.3 3.0 159.6 22.5 1.0 1./Kg O./mm Center to End In. C to E O.7 8.38 98.0 51⁄2 O.236 5.996 13⁄4 13⁄4 17⁄8 2 11⁄2 2 1 11⁄2 2 1 11⁄2 2 1 11⁄2 2 1 2 ⁄2 95 4C 2 ⁄2 57 21⁄2 C 2 ⁄2 65 80 2 ⁄2 2.2 48.9 23.anvilintl.6 89 3 ⁄2 C 1 10 12 6 ⁄2 O.5 7.2 125 61⁄4 O.9 11.500 88.3 6.000 18.5 5. 7052 22 ⁄2° Elbow 1 fiG.28 44.000 20.1 5.2 48.GruVLoK FIttInGS fiG./DN(mm) FIGurE 7052i 221⁄2° ELBoW* Nominal Size In.675 1.5 10.6 18.7 5 165.68 27⁄8 50.7 0.0 139. all others are fabricated steel.0 80.D.3 41.3 21⁄4 C 57 70 70 83 0.8 11⁄4 32 40 50 65 3 O.9 102 41⁄4 C 108 76. 51⁄4 C 10.4 0.0 100 51⁄4 O.4 4 5 6 8 4. visit our website at www.9 355.4 457.3 1.5 36.5 32.7 5.4 42.3 60.D.3 2.5 82 10 12 14 16 18 20 24 43⁄4 C 51⁄4 C 83⁄4 10 10 C 254 533 610 686 762 914 50.0 222. O.75 37/8 43/8 4 /8 7 18.03 27⁄8 73.0 100.4 2.000 24.1 6.9 114.0 4 133.2 65.375 2.0 490.2 10 12 14 16 18 20 24 53.7 5.0 146.500 88.D.750 12.3 20.625 10.315 33.3 219.5 1.875 3.000 18.0 609. O. to End Wt.0 1.000 24. 7051 45° Elbow* fiG.0 111⁄4 286 317 381 121⁄2 15 C .9 17.D.000 16. 108. to End Wt.0 76. 21 24 27 30 36 169.0 609.3 15.6 13⁄4 13⁄4 17⁄8 C 2 0. 139. 7052i 22 1⁄2° Elbow C to E C to E O.500 114.175 7.1 273. Wt.7 5 159.0 115.6 4.3 168.5 7.6 4.4 3.4 46.D.7 5.2 5. In.3 219. to End Wt.43 111. * 14”-24” Standard Radius 90° & 45° Elbows are 1 1⁄2.5 1./DN(mm) O.45 44.625 168.0 156.500 133.3 5.750 12. In.5 0.3 73.0 179. Lbs.2 17.0 1.0 117.000 16.com or contact an Anvil® Sales Representative.9 3. Ea.D.7 5 159.0 52.259 6.0 2.4 42.4 7.500 76 31⁄4 C 83 3C 83 2.3 50.1 323.1 3.625 168.2 0.250 41⁄2 C 114 43⁄4 C 5.000 101.000 41⁄4 C 108 121 133 222 254 19.0 108./mm Center Approx.500 88.3 141.000 73⁄4 C 9C 30.0 609.0 15.3 0.6 11. 108.900 2.1 6.6 406.900 2.9 64 21⁄2 C 64 1.1 6 150 200 250 300 350 400 450 500 600 89 31⁄2 C 89 5.1 323.000 27⁄8 3 ⁄8 C 1 7.7 100 51⁄4 O.2 508.0 88.D.0 4.315 33.D.375 2.5 1. Center to end dimensions and weights may differ from those shown in chart.500 3.5 0.1 273. 1.563 141./Kg O.907 2.1 3.9 2.7 222.375 2.625 8.402 10.9 1.750 14.9 1.000 18./DN(mm) FIGurE 7051 45° ELBoW* Nominal Size In.1 6 150 200 250 300 350 400 450 500 600 165 61⁄2 C 165 197 229 7.1 6 150 200 250 139.7 0.3 37.D.13 4.3 6.3 219.0 4.4 42.5 9.9 355.680 0./mm Center Approx.875 73.0 112.3 219. 8 8.315 33.6 25 1 1.0 0.236 5.563 141.3 0. C to E C to E O.2 48.D.Cast malleable or ductile iron.660 1.1 11⁄4 32 40 50 65 3 O. 139. Ea.8 1.3 3.8 30.D.000 16.5 48.6 4 4.D.0 83 31⁄4 C 83 31⁄2 C 10 12 14 16 18 20 24 43⁄8 47⁄8 5 5 165.227 0. 52 www.D.391 14.1 79.750 12.2 81.63 50.5 165.2 8.4 457.03 31⁄8 3.7 4.454 0. In.2 508.2 1.375 2.625 10.3 60. In.3 6.D.000 20.5 7./DN(mm) FIGurE 7052 221⁄2° ELBoW* Nominal Size In.5 2.D.500 57.0 4.625 168.6 4.5 0.454 0.500 4.772 All 7052i fittings are cast ductile iron.2 48.660 1.3 7.5 3 21⁄4 C 57 64 31⁄2 90 100 125 150 200 250 300 350 400 450 500 600 21⁄2 25⁄8 C 67 73 79 98 76.0 1.83 21.0 31⁄2 4.9 16.1 37⁄8 C 111 124 127 127 140 152 178 125 61/2 O.900 2.D./mm Approx.0 92.741 4.9 0.anvilintl.8 5.1 6.3 5. In.5 0.15 66.45 47.8 133.1 3 80 90 41⁄4 O.1 3.0 108.4 457.7 25 1 1.8 1. Ea.7 41.7 127. 1.0 165.8 25 1 1.0 165.9 355./Kg 25 1 1.2 0.6 406.268 7.0 2.536 8.0 3.1 237.500 127 51⁄4 C 121 5C 133 3.9 123.750 14.2 4.0 4 133.3 0.4 3. 139.D.996 13⁄4 C 13⁄4 C 2C 2 ⁄4 C 1 0. Ea. In.com GL-6./mm Lbs.4 42./Kg O.500 114.2 3.0 5. 76.0 139.6 406.4 159.563 141.0 2.250 23⁄4 C 70 27⁄8 C 4.625 10.0 255.0 4.000 101.1 273.0 76. 76.11 .7 31⁄2 4.1 3 80 100 51/2 O. visit our website at www.7 4.4 21⁄2 64 0.3 2 51 5.12 53 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.0 15.1 16 400 16.0 121⁄2 317 179.0 66.0 20 500 20.2 3. FIGurE 7053 111⁄4° ELBoW* Nominal Size In.660 42.4 4 100 4.4 24 610 222.375 60.9 3 80 3.2 111⁄4 286 146.D.1 15 381 59.2 27 686 280.1 1 25 1.1 18 450 18.2 6 150 6.2 10 250 10.6 6 152 96.5 8 200 8.8 11⁄2 40 1.3 51⁄2 140 17.4 7.7 0.563 141.2 24 600 24.0 53⁄4 146 4./mm Center to End In.1 2 51 10.8 1.4 31⁄2 89 0.GruVLoK FIttInGS 11 ⁄4° Elbow 1 90° Long Radius Elbow* 45° Long Radius Elbow* C to E O.5 6 150 6. Ea.3 2.500 88. In.625 219.000 101.9 0.anvilintl.6 14 350 14.0 3 76 2.000 101.750 273.9 3 80 3.0 11⁄2 38 1.3 0. Ea.2 4 100 4.0 156.0 41.000 508. Lbs.9 33⁄8 86 4.2 20 500 20.0 81.4 31⁄2 90 4.3 21⁄2 64 1.500 114.000 609.9 21 533 147./mm Nominal Size In.3 11⁄4 32 1.315 33.D.9 8 200 8.D.7 0.7 21⁄2 65 2.9 6 150 6.8 20 500 20.750 323. 7053 fiG.875 73.1 2 50 2.7 12 300 12.4 10 254 117.1 71⁄4 184 34.5 14 350 14.315 33.0 47.000 406.com or contact an Anvil® Sales Representative./mm Approx.0 0.9 9.000 406. Lbs.4 1 25 1.9 0.4 4 102 42.0 43.6 13⁄4 44 2.7 16 400 16.0 66.5 2.563 141.3 91⁄2 241 20.3 103⁄4 273 29.5 11⁄2 40 1. Contact an Anvil Representative for more information. C to E O.3 31⁄2 90 4.3 11⁄2 40 1.0 18 450 18.6 83⁄4 222 92.4 2 50 2.000 609.0 0./mm Nominal Size In.3 13⁄8 35 0.625 219.5 24 600 24.7 C ./Kg 1 25 1.0 53.750 323.500 114.9 11⁄2 38 2.0 4.2 37⁄8 98 1./Kg FIGurE 7051 Lr LonG rAdIuS 45° ELBoW* Approx.900 48.000 508.315 33.3 71⁄2 191 11.0 2.3 0. In./mm Center to End In.7 8. Ea.0 5 127 65.900 48.Cast malleable or ductile iron.9 8 200 8.6 21 533 169.563 141.5 2 50 2.6 37.000 406.5 5 125 5./Kg O.3 4 102 7.000 355.500 114.625 168.3 2.2 26.3 23⁄4 70 1.4 10 250 10.6 10 250 10. 7050lr fiG.0 31⁄2 90 4.9 10 254 82.875 73.0 115.3 3 80 3.3 43⁄8 136 2.9 57⁄8 181 6.2 13⁄8 35 0.D.4 13⁄8 35 0.3 5 125 5./DN(mm) FIGurE 7050 Lr LonG rAdIuS 90° ELBoW* Approx.625 219.7 29.2 24.500 88.5 0.4 26.2 41⁄2 114 53./DN(mm) O.2 21⁄2 64 1.000 355.3 24 600 24.7 0.625 168.anvilintl.5 2.000 457. C to E O.6 71⁄4 184 9. Center to end dimensions and weights may differ from those shown in chart.660 42.7 0.2 5.5 5.2 21⁄2 65 2. For Listings/Approval Details and Limitations.6 15 381 255.1 81⁄2 216 57.1 18 457 104.3 2 51 6./DN(mm) O.1 13.2 11⁄4 32 1.375 60.0 12 300 12. In.625 168.5 4 100 4.6 11⁄4 32 1.9 21⁄4 57 18.8 21⁄2 65 2.3 13⁄8 35 0.750 273. * 14"-24" Standard Radius 90° & 45° Elbows are 1 1⁄ 2.D.000 457.0 30 762 344.0 76.5 1.6 36 914 490.5 12 300 12.7 14 350 14.3 13⁄4 44 3.D.7 16 400 16.3 5 127 12./mm Center to End In.9 1.000 609.5 0.1 14.660 42.2 0.0 19.6 31⁄2 89 5.375 60. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.6 31⁄2 89 32.0 222.1 18 450 18. Wt.750 273. 7051lr .3 5 125 5.500 88.0 100.1 21⁄8 54 14. Wt.000 457.3 41⁄4 108 1.5 6.000 508.com GL-7.0 127.875 73. all others are fabricated steel.9 2. www.750 323.3 1.000 355. Wt. Lbs.000 101.900 48. 9 85./Kg 11⁄4 x 11⁄4 x 1 11⁄2 x 11⁄2 x 1 11⁄2 x 11⁄2 x 11⁄4 40 x 40 x 32 50 x 50 x 25 50 x 50 x 32 40 x 40 x 25 32 x 32 x 25 23⁄4 23⁄4 23⁄4 31⁄4 C 31⁄4 31⁄4 C 33⁄4 33⁄4 33⁄4 33⁄4 41⁄4 C 108 108 95 95 95 95 83 83 83 70 70 70 1.5 2.750 323.2 155.0 3x3x1 73⁄4C 9 18 x 18 x 6 18 x 18 x 8 4 100 4.8 4.6 34.8 2 x 2 x 11⁄4 2 x 2 x 11⁄2 8 x 8 x 11⁄2 8x8x2 73⁄4 73⁄4 2 50 2.1 58.2 11.2 23⁄4 70 23⁄4 70 1.0 78.7 23.7 47.5 28.9 41⁄4 108 6 152 8.3 77.6 2x2x1 12 12 12 126 127 128 11⁄2 40 1.8 0.9 24./mm Approx.0 88.2 76.0 12.3 24.9 0.anvilintl.5 21.3 14.D.0 5.1 9 229 9 229 73.0 44. Ea.9 109.2 34. Lbs.0 53.4 0.2 5.875 73.5 6.3 34.0 80. Lbs.2 47.6 34.0 52.9 29.4 24 x 24 x 10 24 x 24 x 12 24 x 24 x 14 24 x 24 x 16 24 x 24 x 18 24 x 24 x 20 20 20 20 20 20 20 330 334 340 342 345 347 For Listings/Approval Details and Limitations.9 20.4 21⁄4 57 21⁄4 57 0.9 1. Lbs.5 6.2 55.0 14.3 7.900 48.2 92.0 59. contact an Anvil Representative for more information.6 24.6 11.2 5.0 12.7 0.5 113.7 12.7 2. Ea.500 88.com GL-6.7 2.2 15.2 57.7 111.1 20 x 20 x 8 438 438 1 1 240 242 5C 20 x 20 x 10 17 ⁄4 17 ⁄4 17 ⁄4 1 1 12 300 12.9 23.8 15.625 168.5 1.11 .6 1./mm Approx.Cast malleable or ductile iron.500 114.6 58.2 0.0 32./DN(mm) Center to End In.1 4.0 23.com or contact an Anvil® Sales Representative.5 26.6 10.4 3.0 2. Wt.8 5. C to E C to E Fabricated C to TE FIGurE 7063 tEE WItH tHrEAdEd BrAncH Nominal Size In. Wt.7 73⁄4 C 197 197 197 229 229 229 229 229 229 229 229 254 254 254 254 254 254 254 254 254 279 197 73⁄4 151⁄2 151⁄2 151⁄2 15 ⁄2 1 305 394 188 31⁄2 90 4.6 112./Kg Nominal Size In.3 4.2 11.8 6.1 3./mm C to TE In.3 6.6 13.1 9./mm C to GE In.3 5 127 71⁄4 184 13.1 108.2 87.7 151.0 74.9 1.0 33.2 4. 7061 Reducing Tee Standard C to E O./Kg Nominal Size In. Wt.7 15.3 21⁄2 x 21⁄2 x 1 21⁄2 x 21⁄2 x 11⁄4 21⁄2 x 21⁄2 x 11⁄2 21⁄2 x 21⁄2 x 2 65 x 65 x 50 80 x 80 x 25 80 x 80 x 32 80 x 80 x 40 80 x 80 x 50 80 x 80 x 65 100 x 100 x 25 100 x 100 x 32 100 x 100 x 40 100 x 100 x 50 100 x 100 x 65 100 x 100 x 80 125 x 125 x 25 125 x 125 x 40 125 x 125 x 50 125 x 125 x 65 125 x 125 x 80 65 x 65 x 40 65 x 65 x 32 65 x 65 x 25 50 x 50 x 40 8 x 8 x 21⁄2 8x8x3 8x8x4 8x8x5 8x8x6 73⁄4 73⁄4 16 x 16 x 10 16 x 16 x 12 16 x 16 x 14 18 x 18 x 4 12 12 12 129 130 132 21⁄2 65 2.9 91.2 10.5 59.D.4 36. all others are fabricated steel.750 273.1 3 80 3. Lbs.6 57. 6 ⁄2 C 1 165 6 ⁄2 11 11 101 54 www.7 1 25 1.4 103 104 105 11⁄4 32 1.4 4 x 4 x 1 ⁄4 4 x 4 x 1 ⁄2 4x4x2 1 127 127 127 127 127 140 140 140 140 5 5 17 ⁄4 17 ⁄4 1 394 10 250 10.2 2.5 50.9 1.7 22./mm Approx.0 26.6 53. C to E Cast O.1 75.0 64.1 88.3 9.D.6 4.8 1.0 350 x 350 x 200 350 x 350 x 250 350 x 350 x 300 400 x 400 x 100 400 x 400 x 150 400 x 400 x 200 400 x 400 x 250 400 x 400 x 300 400 x 400 x 350 450 x 450 x 100 450 x 450 x 150 450 x 450 x 200 450 x 450 x 250 450 x 450 x 300 450 x 450 x 350 450 x 450 x 400 500 x 500 x 150 500 x 500 x 200 500 x 500 x 250 500 x 500 x 300 500 x 500 x 350 500 x 500 x 400 500 x 500 x 450 600 x 600 x 200 600 x 600 x 250 600 x 600 x 300 600 x 600 x 350 600 x 600 x 400 600 x 600 x 450 14 x 14 x 8 14 x 14 x 10 14 x 14 x 12 16 x 16 x 4 16 x 16 x 6 16 x 16 x 8 279 279 279 305 305 305 305 305 11 11 11 46.3 6 ⁄2 1 6 ⁄2 1 25.5 6. In.0 12.4 6.8 0.3 86. See Fitting Size chart on page 51 for O./DN(mm) Center to End In.1 33. Wt.7 77.3 31⁄4 83 41⁄4 108 2.7 4.660 42.7 33.GruVLoK FIttInGS fiG.0 34. 125 x 125 x 100 150 x 150 x 25 150 x 150 x 40 5 ⁄2 C 140 165 140 6 ⁄2 1 1 12 x 12 x 10 14 x 14 x 4 14 x 14 x 6 10 C . Ea.anvilintl.D. 7063 Tee w/ Threaded Branch fiG. C to GE O.5 4 x 4 x 2 ⁄2 4x4x3 5x5x1 1 5C 10 10 20 x 20 x 12 438 244 5C 5 ⁄2 1 1 1 1 1 20 x 20 x 14 20 x 20 x 16 438 438 1 246 248 12 x 12 x 2 ⁄2 12 x 12 x 3 12 x 12 x 4 12 x 12 x 5 12 x 12 x 6 12 x 12 x 8 10 17 ⁄4 17 ⁄4 438 508 508 508 508 508 508 438 250 252 5 x 5 x 1 ⁄2 5x5x2 1 5 ⁄2 5 ⁄2 10 10 10 10 10 20 x 20 x 18 24 x 24 x 8 14 20 327 5 x 5 x 2 ⁄2 5x5x3 5x5x4 6x6x1 1 5 ⁄2 5 ⁄2 1 14.7 54.6 24.8 2.4 114.1 3 x 3 x 11⁄4 3 x 3 x 1 ⁄2 1 41⁄4 4 ⁄4 1 1 10 x 10 x 11⁄2 10 x 10 x 2 1 394 190 5 125 5.7 7.2 52.6 8.0 350 x 350 x 150 279 45.3 148.1 4.5 26.0 52.0 9.6 54.6 3x3x2 1 4 ⁄4 C 108 108 108 9 18 x 18 x 10 18 x 18 x 12 394 394 1 1 192 194 10 x 10 x 2 ⁄2 10 x 10 x 3 10 x 10 x 4 10 x 10 x 5 10 x 10 x 6 10 x 10 x 8 12 x 12 x 1 12 x 12 x 2 1 9 15 ⁄2 15 ⁄2 15 ⁄2 1 1 6 150 6.8 110.D.1 73⁄4 197 73⁄4 197 45. Ea.315 33.8 35.6 76.3 34.6 41⁄2 114 41⁄2 114 8.5 157.8 600 x 600 x 500 508 Center to end dimensions and weights may differ from those shown in chart.6 3 x 3 x 2 ⁄2 4x4x1 1 1 4 ⁄4 1 3 9 9 9 9 9 18 x 18 x 14 394 394 196 201 203 165 165 3 ⁄4 95 18 x 18 x 16 20 x 20 x 6 8 200 8. visit our website at www.3 149.9 2./Kg Center to End In.7 2.0 20.000 101.2 0. 6 x 6 x 1 ⁄2 6x6x2 150 x 150 x 50 165 12.563 140 51⁄2 140 51⁄2 140 16.3 23⁄4 70 23⁄4 70 1.9 10 254 10 254 98.5 154.6 17.375 60./DN(mm) FIGurE 7061 StAndArd rEducInG tEE Nominal Size In.1 156.3 24.4 7.4 13.2 2./mm Approx.6 100.5 6./DN(mm) O.0 33⁄4 95 33⁄4 95 4.6 4.8 1.5 15.0 33.6 75.0 33.4 35.6 3.0 45.9 5.625 219.4 150 x 150 x 65 150 x 150 x 80 150 x 150 x 100 150 x 150 x 125 200 x 200 x 40 200 x 200 x 50 200 x 200 x 65 200 x 200 x 80 200 x 200 x 100 200 x 200 x 125 200 x 200 x 150 250 x 250 x 40 250 x 250 x 50 250 x 250 x 65 250 x 250 x 80 250 x 250 x 100 250 x 250 x 125 250 x 250 x 150 250 x 250 x 200 300 x 300 x 25 300 x 300 x 50 300 x 300 x 65 300 x 300 x 80 300 x 300 x 100 300 x 300 x 125 300 x 300 x 150 300 x 300 x 200 300 x 300 x 250 350 x 350 x 100 6 x 6 x 21⁄2 6x6x3 6x6x4 6x6x5 61⁄2 C 61⁄2 C 61⁄2 C 61⁄2 C 165 197 197 197 165 165 165 26.0 1. 0 204.1 55.8 1.3 5. Wt.0 334.2 48.D.4 0.500 88.8 43.6 2.3 219.0 64.2 3.6 2 2 1.4 5 8 8.3 5.8 87.D.3 4.7 11.1 25.1 4.GruVLoK FIttInGS Reducing Tee w/ Threaded Branch Tee C to E Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.5 16.625 10.5 66.3 4 ⁄4 3 x 3 x 2 ⁄2 4 x 4 x ⁄4 3 4 ⁄4 3 ⁄4 33⁄4 95 95 100 51⁄4 O.D.0 209.5 26.4 3.3 60.6 5.7 14.7 5 159.5 5.750 14.4 63. 7064 C to E O.0 275.1 1 ⁄4 32 40 50 65 3 O.8 7.0 95. Ea.000 108.0 4.0 211.5 38.0 9.375 2.500 141.4 14.1 6.7 18.660 1.900 2.8 92.4 4 x 4 x 21⁄2 4x4x3 5x5x2 5x5x3 5x5x4 6x6x2 5 14 x 14 x 10 14 x 14 x 12 16 x 16 x 8 11.9 355.2 94.com GL-6.563 159.9 38.com or contact an Anvil® Sales Representative. 4x4x1 4 x 4 x 11⁄2 4x4x2 127 127 127 127 140 140 140 165 165 165 165 165 197 197 5 12 x 12 x 10 14 x 14 x 8 125 61⁄4 O.875 76. Lbs.0 379.2 0.7 0.anvilintl.500 114.3 24.3 6./DN(mm) Center to End In. Ea.0 114.7 7.D.0 41.0 53. Lbs/Kg Nominal Size In.2 7.1 273. For Listings/Approval Details and Limitations. 61⁄2 O. 140 51⁄2 C 152 165 61⁄2 C 165 197 229 61⁄2 C 140 6C 51⁄2 C 7.500 133.7 94.2 11.9 0.996 2 ⁄4 C 3 1.7 17. C to E O.0 2.6 17 12.4 4.9 26.0 218.0 349.0 28.0 165.2 3.0 64. www. Ea.0 37.4 5.6 6.0 342.D.0 88.3 21⁄4 C 57 70 70 83 0.5 18.1 3 80 41⁄4 C 4 ⁄4 1 1 1 3 3 x 3 x 1 ⁄2 3x3x2 1 10 10 10 10 10 10 11 11 11 12 12 12 90 41⁄4 O.236 101.5 94.6 2. In.5 29.000 16.7 43.0 24.0 146.3 6. 7060 O.D.8 2.4 51⁄2 O.000 24.2 508./DN(mm) FIGurE 7060 – tEE Nominal Size In.0 54.2 7.5 26. See Fitting Size chart on page 51 for O.8 110./Kg 50 x 50 x 20 50 x 50 x 25 50 x 50 x 32 2 x 2 x 3⁄4 2x2x1 31⁄4 31⁄4 C 31⁄4 31⁄4 C 33⁄4 33⁄4 33⁄4 108 108 108 108 108 95 95 95 83 83 83 83 1.0 41.5 1.D.2 2.0 158 155 152 98.9 73. 108.3 4.1 5.8 4.D.5 38.1 323. Lbs/Kg O.259 5. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.0 142.6 1.1 5 9.D.7 200 x 200 x 100 200 x 200 x 125 200 x 200 x 150 250 x 250 x 50 250 x 250 x 80 250 x 250 x 100 250 x 250 x 125 250 x 250 x 150 250 x 250 x 200 300 x 300 x 80 300 x 300 x 100 300 x 300 x 125 300 x 300 x 150 300 x 300 x 200 300 x 300 x 250 350 x 350 x 200 350 x 350 x 250 350 x 350 x 300 400 x 400 x 200 400 x 400 x 250 400 x 400 x 300 450 x 450 x 250 450 x 450 x 300 450 x 450 x 350 450 x 450 x 400 600 x 600 x 200 600 x 600 x 250 600 x 600 x 300 8x8x4 8x8x5 8x8x6 197 197 197 229 229 229 229 229 229 254 254 254 254 254 254 279 279 279 305 305 73⁄4 73⁄4 73⁄4 9 9 9 9 9 9 50.315 33.4 40.750 12.6 4. visit our website at www.1 6 150 200 250 300 350 400 450 500 600 127 51⁄4 C 121 5C 133 6./mm Center to End In.3 16.anvilintl.3 91.6 1.2 10.5 49.D.2 11.6 4.9 1.0 139.3 20.4 457.0 5.0 51⁄2 51⁄2 51⁄2 61⁄2 10 12 14 16 18 20 24 16 x 16 x 10 16 x 16 x 12 18 x 18 x 10 18 x 18 x 12 18 x 18 x 14 18 x 18 x 16 24 x 24 x 8 10 C 254 279 305 151⁄2 151⁄2 151⁄2 151⁄2 508 508 508 0 0 394 394 305 11 12 6 x 6 x 21⁄2 6x6x3 6x6x4 6x6x5 8x8x2 8x8x3 61⁄2 61⁄2 61⁄2 6 ⁄2 1 3 3 151⁄2 394 438 508 171⁄4 20 20 20 20 7 ⁄4 7 ⁄4 24 x 24 x 10 24 x 24 x 12 C .0 65.2 0. Wt. Cast Fabricated FIGurE 7064 rEducInG tEE WItH tHrEAdEd BrAncH Nominal Size In.7 12 12 12 12 8.0 135.625 168.5 2. C to E C to E C to E Cast Fabricated fiG.1 3.000 18./mm Approx.5 28.0 139.0 4 133.2 98.0 117.9 85.0 165.7 118.000 20.D.0 609.8 4.8 16.4 42.0 61.0 61.0 139. all others are fabricated steel.6 22.4 9.D./mm Approx.Cast malleable or ductile iron.8 51.1 4.250 41⁄2 C 114 43⁄4 C 9.3 2.9 29.1 4.5 64. Wt.000 73⁄4 C 9C 41.7 4.5 29. 31⁄2 4.8 1.2 10. C to E C to E O./DN(mm) Center to End In.1 39.9 125 172 24.7 84.7 5.1 17.11 55 .6 33.1 7.0 216.8 2.0 2.6 406.2 5.1 74.2 52./mm Approx.8 63. 1.4 26.6 2 x 2 x 11⁄4 2 x 2 x 11⁄2 11⁄2 2 23⁄4 C 31⁄4 C 33⁄4 C 101 41⁄4 C 108 95 4C 21⁄2 x 21⁄2 x 1 21⁄2 x 21⁄2 x 11⁄2 21⁄2 x 21⁄2 x 2 65 x 65 x 50 80 x 80 x 20 80 x 80 x 25 80 x 80 x 40 80 x 80 x 50 80 x 80 x 65 100 x 100 x 20 100 x 100 x 25 100 x 100 x 40 100 x 100 x 50 100 x 100 x 65 100 x 100 x 80 125 x 125 x 50 125 x 125 x 80 125 x 125 x 100 150 x 150 x 50 150 x 150 x 65 150 x 150 x 80 150 x 150 x 100 150 x 150 x 125 200 x 200 x 50 200 x 200 x 80 65 x 65 x 40 65 x 65 x 25 50 x 50 x 40 10 x 10 x 2 10 x 10 x 3 10 x 10 x 4 10 x 10 x 5 10 x 10 x 6 10 x 10 x 8 12 x 12 x 3 12 x 12 x 4 12 x 12 x 5 12 x 12 x 6 12 x 12 x 8 21⁄2 3 x 3 x 3⁄4 3x3x1 1 41⁄4 76.7 2.7 25 1 1 1.6 28. 8 5.5 20 x 18 500 x 450 20 508 160 72.GruVLoK FIttInGS fiG.7 0.7 0.0 0.5 0. Ea. See Fitting Size chart on page 51 for O.9 4 x 1 ⁄2 4x2 3 80 x 40 241 3x2 80 x 50 91⁄2 241 4.3 11⁄4 x 1 32 x 25 81⁄2 216 1. Wt./mm Approx.7 2.2 7. x Gr.3 1./Kg Nominal Size In.9 2 x 3⁄4 50 x 80 9 229 2.0 8x4 200 x 100 12 305 19.D.4 24 x 10 600 x 250 20 508 174 78.9 2.7 14.7 4.4 16 x 10 400 x 250 14 356 96 43. For Listings/Approval Details and Limitations.5 4.7 4 x 31⁄2 100 x 90 10 254 8.7 10 x 6 250 x 150 13 330 34.2 1.3 3.3 1.6 0.9 20 x 12 500 x 300 20 508 149 67.1 1.5 4 4 4 4 4 4 x 1 ⁄2 1 10 254 6.6 4x1 1 3 3 x 1 ⁄2 1 9 ⁄2 1 4.0 23.11 .3 2. Wt.0 1.0 10 x 5 250 x 125 13 330 31.0 6.4 1.3 2.3 4x3 100 x 80 10 254 7.7 3.6 See Fitting Size chart on page 51 for O.9 14 x 12 350 x 300 13 330 88 39.3 1.2 14 x 8 350 x 200 13 330 80 36. 7097 Eccentric Reducers E to E O.3 1.9 5.8 2.D.2 1.2 1.9 3 x 21⁄2 31⁄2 x 3 100 x 25 100 x 40 100 x 50 100 x 65 100 x 80 100 x 90 125 x 100 150 x 25 150 x 50 150 x 80 150 x 100 150 x 125 3x1 80 x 25 91⁄2 241 4.7 100 x 40 4x2 100 x 50 10 254 6.5 1. Contact an Anvil Representative for more information. Center to end dimensions may differ from those shown above.9 6.0 1.0 1.5 3.9 5.8 3 3 x 2 ⁄2 1 9 ⁄2 1 5. E to E O.5 0.4 24 x 12 600 x 300 20 508 179 81.7 21.5 21⁄2 x 11⁄4 21⁄2 x 11⁄2 21⁄2 x 2 3 x 3⁄4 3x1 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 3 2 x 11⁄4 50 x 32 9 229 2.5 6.3 11⁄2 x 1 40 x 25 81⁄2 216 1.5 0. Lbs.3 3 x 11⁄2 80 x 40 80 x 50 80 x 65 90 x 80 80 x 25 21⁄2 x 11⁄2 65 x 40 91⁄2 241 3.5 14 x 10 350 x 250 13 330 84 38.7 5x2 125 x 50 11 279 9.0 5.0 5x4 125 x 100 11 279 11.4 16 x 8 400 x 200 14 356 91 41.6 24 x 20 600 x 500 20 508 199 90.9 12 x 4 300 x 100 14 356 44.3 18 x 16 450 x 400 15 381 121 54. Fabricated Steel *Figure 7097 is available in sizes 11⁄4 x 1 through 12 x 10.3 1.8 8x3 200 x 80 12 305 17./DN(mm) Approx.0 6x1 150 x 25 111⁄2 292 12.2 5.9 14 x 6 350 x 150 13 330 78 35.7 20 x 14 500 x 350 20 508 152 68.0 12 x 6 300 x 150 14 356 45.7 2.3 2.3 12 x 8 300 x 200 14 356 47.6 2. Lbs.9 2 x 11⁄2 50 x 40 9 229 2.D.8 0.2 18 x 12 450 x 300 15 381 113 51.8 2. concEntrIc rEducEr GrooVE BY tHrEAd Nominal Size In.com GL-6.4 15.1 6 x 11⁄2 150 x 40 111⁄2 292 12./Kg End to End In.com or contact an Anvil® Sales Representative.6 0. Fabricated Fig.anvilintl.5 2.8 18 x 14 450 x 350 15 381 117 53.5 6x3 150 x 80 111⁄2 292 13.5 16 x 14 400 x 350 14 356 104 47.2 1.2 2.1 5.6 12 x 10 300 x 250 14 356 52.7 8. All are Fabricated Steel.5 0.6 6x4 150 x 100 111⁄2 292 14.6 0.8 18 x 10 450 x 250 15 381 110 49.5 2.0 5.7 2. 7073– Gr.8 5 x 21⁄2 125 x 65 11 279 9. 7073 & fiG. Ea.5 0.6 1./Kg Nominal Size In.6 4 x 21⁄2 4x3 3 80 x 65 241 31⁄2 x 3 90 x 80 91⁄2 241 6.0 1.0 5x3 125 x 80 11 279 10.1 6x2 150 x 50 111⁄2 292 12.9 8.6 2.0 15./mm FIGurE 7073 & 7097 EccEntrIc rEducEr Nominal Size In.3 2.8 1.0 1.7 2.8 20.3 4.6 3.9 3 4 x 31⁄2 5x4 6x1 6x2 6x3 6x4 6x5 31⁄2 89 102 102 102 102 102 76 3 4x1 100 x 25 10 254 5./DN(mm) End to End In. Wt./mm Approx.0 1.2 10. Lbs.3 24 x 16 600 x 400 20 508 189 85.4 2.9 3.1 3x2 21⁄2 x 2 65 x 50 91⁄2 241 4.4 1.1 20 x 10 500 x 250 20 508 145 65. See Fitting Size chart on page 51 for O. Fabricated Fig.5 1.6 1.5 0. E to E O.1 2 x 11⁄4 2 x 11⁄2 2 ⁄2 x 1 1 50 x 25 50 x 32 50 x 40 65 x 25 65 x 32 65 x 40 65 x 50 80 x 80 11⁄2 x 11⁄4 40 x 32 81⁄2 216 4.5 6 x 21⁄2 150 x 65 111⁄2 292 12. visit our website at www.2 21⁄2 x 1 65 x 25 91⁄2 241 3.0 6.5 20 x 16 500 x 400 20 508 156 70.2 1.9 10 x 8 250 x 200 13 330 34. Ea.D.6 24 x 14 600 x 350 20 508 184 83.anvilintl./DN(mm) FIGurE 7076 – End to End In.4 0./DN(mm) End to End In.6 0.2 20.8 3 x 11⁄4 80 x 32 91⁄2 241 4./Kg 11⁄2 x 1 40 x 25 50 x 80 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 2 ⁄2 1 2 x 3⁄4 2x1 64 64 64 64 64 64 64 64 64 64 64 64 64 64 76 76 76 76 76 76 0. x Thd.5 16 x 12 400 x 300 14 356 99 44.6 0.0 1.3 2x1 50 x 25 9 229 2.6 6.7 13.2 1. 7076 Gr x Thd Concentric Reducers fiG. Lbs.6 2.8 6x5 150 x 125 111⁄2 292 16.D.4 9.0 0. Ea. 7097 – Gr. Wt.0 8x5 200 x 125 12 305 21. 56 www.5 24 x 18 600 x 450 20 508 194 88 4 x 21⁄2 100 x 65 10 254 7.9 4.6 0./mm Approx.5 0.2 8x6 200 x 150 12 305 23.0 1.D.3 2.5 10 x 4 250 x 100 13 330 29.2 4 x 11⁄4 100 x 32 10 254 6.9 21⁄2 x 11⁄4 65 x 32 91⁄2 241 3.1 1.4 11⁄2 x 3⁄4 40 x 20 81⁄2 216 1.8 2. 5 3. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.0 8.6 3. Wt. Fig.0 12. 7077. 7078 Gr x Thd E to E O.anvilintl.0 3.com GL-6.0 17.0 12. Ea.6 8.6 3.6 1.0 8.0 9 This product is not ULC Listed.0 19.0 12.0 8.0 8.2 100 x 65 100 x 80 100 x 90 125 x 50 125 x 65 125 x 80 125 x 100 150 x 25 150 x 32 150 x 40 150 x 50 150 x 65 150 x 80 150 x 90 150 x 100 150 x 125 4 x 21⁄2 4x3 229 229 229 279 279 279 279 305 305 305 305 305 305 305 305 305 9 8.4 2 x 11⁄2 21⁄2 x 1 21⁄2 x 11⁄4 21⁄2 x 11⁄2 21⁄2 x 2 3x1 4 x 31⁄2 5x2 9 11 7 7 5 x 21⁄2 5x3 5x4 6x1 11 11 11 12 7 8 19.3 2.D. Lbs.0 19.3 2.6 1. Lbs. Wt.0 19.0 3.0 3.D.com or contact an Anvil® Sales Representative./mm Approx. www.7 3 x 11⁄4 80 x 32 80 x 40 80 x 50 8 8 6 x 11⁄4 6 x 11⁄2 6x2 12 12 19.0 0.3 2./Kg 50 x 25 2x1 61⁄2 C 165 165 165 178 178 178 178 203 203 203 203 203 203 229 229 229 229 2.9 1. For Listings/Approval Details and Limitations.6 5.D. 7078 & fiG.6 8.0 5.5 3.D.0 2.0 5.5 5./DN(mm) End to End In.6 2./DN(mm) End to End In.4 5.0 12 12 19. 7079 E to E O. visit our website at www.6 8.6 7.0 5. 7078 & 7079 SWAGEd nIPPLES Nominal Size In.6 8.9 0.0 12.6 3.0 7.0 8. 7079 Gr x Bev FIGurE 7077.6 9 8.5 3.3 2. Fig.GruVLoK FIttInGS Swaged Nipples Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.0 19. Ea.4 2 x 11⁄4 50 x 32 50 x 40 65 x 25 65 x 32 65 x 40 65 x 50 80 x 25 61⁄2 61⁄2 7 2.9 0.3 3.0 19./Kg Nominal Size In.6 3. 7077 Gr x Gr E to E O.11 57 .6 3.anvilintl. fiG. Fig.0 5.4 5.0 8.6 3 x 11⁄2 3x2 8 12 3 x 21⁄2 80 x 65 90 x 80 8 6 x 21⁄2 6x3 12 31⁄2 x 3 100 x 25 100 x 32 100 x 40 100 x 50 8 12 4x1 9 6 x 31⁄2 6x4 6x5 12 4 x 11⁄4 4 x 11⁄2 4x2 9 9 8.6 8.0 5. See Fitting Size chart on page 51 for O.6 1./mm Approx.6 8. 2 31⁄2 1.563 x 3.0 x 60. to End Wt.5 2.1 6./mm Lbs/Kg FIGurE 7072i concEntrIc rEducEr Nominal Size In.6 86.6 2.0 2.500 x 2.5 55.814 2 x 11⁄4 2 x 11⁄2 21⁄2 x 1 21⁄2 x 11⁄4 21⁄2 x 11⁄2 2 ⁄2 x 2 65 x 50 80 x 25 80 x 32 80 x 40 80 x 50 80 x 65 1 2x1 50 x 25 2.500 101.5 0. x 4 165.5 21⁄2 1.3 3 76.5 4 x 21⁄2 4x3 3x2 80 x 50 3.5 0.1 11⁄4 x 1 32 x 25 1. 165.875 x 1.563 x 2.D.3 2.9 31⁄2 88.625 x 6.3 101.2 4.0 .041 5.660 73.2 3.2 2.900 x 1.900 73.3 x 33.1 3.5 1.680 165.3 200 x 100 200 x 125 200 x 150 250 x 100 250 x 125 250 x 150 250 x 200 300 x 100 300 x 150 300 x 200 300 x 250 350 x 150 350 x 200 350 x 250 350 x 300 400 x 200 400 x 250 400 x 300 400 x 350 450 x 250 450 x 300 450 x 350 450 x 400 500 x 250 500 x 300 500 x 350 500 x 400 500 x 450 600 x 250 600 x 300 600 x 350 600 x 400 600 x 450 600 x 500 8x4 8x5 8x6 127 127 127 152 152 152 152 178 178 178 178 330 330 330 330 356 356 356 356 381 381 381 381 508 508 508 508 508 508 508 508 508 508 508 5C 5 9.0 1.2 x 33.0 4.5 0. In.315 60. to End Wt.1 x 139.680 6x4 150 x 100 6 x 51/2 O.3 x 42. Ea.6 4 2. x 4 139.3 1.4 54.0 x 33.500 101.8 11.5 0.3 21⁄2 63.1 x 33.6 0. x 1 2.1 9.990 11.5 0.2 3 76.9 6.5 4 x 31⁄2 5x2 3 31⁄2 31⁄2 31⁄2 31⁄2 C 89 102 102 102 102 102 102 102 127 5 x 21⁄2 5x3 5x4 6x1 1 80 x 76.0 x 48.7 6x2 150 x 50 165.5 1.0 12.1 139.500 x 2.3 x 114.6 66.6 4 2.9 5.660 x 1.1 x 114./DN(mm) O.454 5x4 125 x 100 61/2 O.1 61/2 O.3 5.680 1. 3. 168. x 11/4 76.3 24.1 2. x 3 5.5 150 x 76.2 1.0 31⁄2 88.948 6.875 114.7 x 100 5x2 125 x 50 139.2 123.D.500 31⁄2 4.9 5.5 0.D.3 x 48./mm Lbs/Kg O.6 0.7 13.7 26.0 129.3 x 88. visit our website at www.5 0.814 25 29 29 2 x 11⁄2 50 x 40 2.0 150 x 139.2 2.5 10 x 8 250 x 200 10.5 3x1 21⁄2 21⁄2 21⁄2 2 ⁄2 C 1 12 x 10 14 x 6 14 x 8 32.454 139.1 1.845 4C 4 6 x 21⁄2 6x3 6x4 6x5 8x3 4C 4C 4C 5 100 x 76.875 168.6 3.2 21⁄2 63.2 87.9 x 60.563 x 2.1 6x3 150 x 80 168.4 66.3 13.5 1.5 1.8 1.0 2.6 14. In.0 4.0 2.563 x 4.9 6. x 3 O.5 4x1 4 x 11⁄4 4 x 11⁄2 4x2 76 76 3 16 x 10 16 x 12 16 x 14 18 x 10 18 x 12 18 x 14 18 x 16 20 x 10 20 x 12 20 x 14 20 x 16 20 x 18 24 x 10 24 x 12 24 x 14 24 x 16 24 x 18 24 x 20 14 14 14 15 15 15 15 20 20 20 20 20 20 20 20 20 20 20 3 3 76.9 30.3 69.134 4 4x2 100 x 50 4.9 x 48.3 3.5 0. x 3 165.0 3.5 14 6 x 21⁄2 150 x 65 6 x 3 O.5 2.0 82.500 114.7 6x5 150 x 125 6 x 61/2 O.814 For Listings/Approval Details and Limitations.996 76.500 x 2.9 37.3 1.3 6.D.5 2.7 0.com or contact an Anvil® Sales Representative.6 4 101.9 4.5 1.625 x 2.500 101.3 29.0 70. Cast O.3 6.1 4x3 100 x 80 51/2 O.134 2./mm Lbs/Kg 11⁄4 x 1 1 ⁄2 x 1 1 32 x 25 40 x 25 40 x 32 50 x 25 50 x 32 50 x 40 65 x 25 65 x 32 65 x 40 1 21⁄2 2 ⁄2 1 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 76 0.6 4 101.625 x 6.536 11.1 8.495 6.5 1.3 x 73.675 273.495 3C 3C 3C 76 76 89 89 89 76 76 76 76.0 152.500 x 2.500 141.500 x 1. 58 www.0 .5 56. In.0 5 127.3 x 60. 6.4 21⁄2 63.com GL-7.9 101.1 x 48.5 0.3 127.D.4 1.0 5.GruVLoK FIttInGS fiG.D.3 2.2 21⁄2 63.500 x 3.6 0.0 25.D.375 141.D. 7072i – Gr x Gr Concentric Reducer E to E O.134 2.3 x 141. C . In. 168.0 133.680 1.500 x 2.D.625 219.9 10.495 5./DN(mm) Nominal End Approx.1 5.5 1.500 x 2.5 14 x 10 14 x 12 16 x 8 13 13 165.3 x 76.5 10.6 0.315 21⁄2 63.6 0.6 4 2.3 6.500 4 101.D.5 21⁄2 2.8 0.4 19. In.134 200 x 165.0 6. 6.1 x 76.500 x 2.-1 O.996 31⁄2 88.625 x 5.4 68.375 x 1.0 0. Fabricated O.563 168.0 139.7 x 80 51/2 O.3 x 165.500 x 2.0 0.3 0.3 65.1 1. 4.7 x 114.5 21⁄2 0.0 6.4 2.3 63.0 4 x 11⁄2 100 x 40 4.6 4 5.D.-2 Sizes 11/4" x 1" to 80mm x 76.5 1.0 4.5 21⁄2 x 2 65 x 50 3 O.9 67.1 8x4 200 x 100 8 x 61/2 O.0 11⁄2 x 11⁄4 2x1 21⁄2 21⁄2 21⁄2 C 21⁄2 C 21⁄2 21⁄2 21⁄2 2 ⁄2 C 1 5C 6 6 11⁄2 x 1 40 x 25 1.2 9.454 5x3 125 x 80 5.0 3 x 11⁄4 3 x 11⁄2 3x2 13 13 21⁄2 x 11⁄2 65 x 40 2.0 x 42.1 4.1 x 40 3 O.7 2.3 x 60.5 1.7 24.Cast malleable or ductile iron.8 39.5 0. 5.5 6.6 4 2.0 21⁄2 x 1 65 x 25 2.625 x 6.996 x 1.375 x 1.6 39.500 168.268 3 x 21⁄2 3 ⁄2 x 3 90 x 80 100 x 25 100 x 32 100 x 40 100 x 50 100 x 65 100 x 80 100 x 90 125 x 50 125 x 65 125 x 80 125 x 100 150 x 25 150 x 40 150 x 50 150 x 65 150 x 80 150 x 100 150 x 125 200 x 80 21⁄2 C 3 76.4 2.315 48.9 69.6 5 127.3 6.D.0 .5 1.0 1.1 x 168.1mm Sizes 4" x 1" and larger FIGurE 7072 concEntrIc rEducEr Nominal End Approx.0 149.3 21⁄2 63.814 4.D.500 x 1.4 5.0 155.9 4 5.D.3 3 76.3 x 73.1 x 219.996 x 1.3 21⁄2 63.8 9.1 8.875 141.1 6 152.315 73.3 0. Size to End Wt.5 0.660 63.3 54.227 51/2 O. all others are fabricated steel.996 x 1.9 4.3 x 88.6 0.680 165.D.1 x 80 61/2 O.D.227 10 x 4 10 x 5 10 x 6 10 x 8 12 x 4 12 x 6 12 x 8 20 20 11⁄2 x 11⁄4 40 x 32 1.9 31⁄2 88.6 2.875 x 1.7 x 76.900 60. Ea.5 3 76.5 21⁄2 63.9 x 73. 7072 – Gr x Gr Concentric Reducer E to E E to E fiG.500 x 1.5 2.1 20 2 x 11⁄4 50 x 32 2.6 0.0 2.3 88./mm Lbs/Kg Nominal Size In.2 2.1 x 76.900 x 1.2 3 2.D.720 7.680 1.8 2.3 x 139.5 2.3 1./DN(mm) In.625 x 5.7 0.454 5 x 21⁄2 125 x 65 5. 114.3 x 114.500 219.4 21⁄2 63.500 x 3.D.134 4.5 21⁄2 0.9 1.1 x 114.0 1.2 1.875 88.3 32.3 8.5 1.6 0.6 4 6. x 3 O.0 11.D.500 101. 139.0 2.996 21⁄2 63.0 131.625 x 3.6 0.3 83.D.500 x 4.375 73.6 1.1 71.7 60.375 88.1 x 100 61/2 O.3 59.875 x 1.0 0.1 6.3 x 42.3 x 73.7 3.3 x 33.7 2.500 88.0 1.7 55.907 3 x 21⁄2 80 x 65 3 x 3 O.3 x 88.660 48.900 88.7 6.2 21⁄2 63.1 37.500 168.990 6 x 1 ⁄2 6x2 4 4 x 21⁄2 100 x 65 4 x 3 O.1 x 139.750 x 8. In.625 x 4.4 2.4 58.5 1.D.3 x 76.9 x 76.2 2./DN(mm) In.0 1.4 0.7 68.625 x 2.7 57.0 .500 x 5.D.5 141.0 2.625 x 2.907 2.5 1.996 x 2.996 4 101.660 60.9 31⁄2 1.0 5 3.5 4.7 x 76.6 4.1 x 88.680 1.1 4x1 100 x 25 88.5 21⁄2 0.680 165.anvilintl.134 150 x 165.D.4 21⁄2 63.0 5.5 76.7 x 88.814 4.900 63.6 4. Ea.1 x 60.2 2.948 6./mm End Approx.500 101.3 1.4 21⁄2 63.D.720 6.315 114.-1 O.5 2.375 168. Size to End Wt.0 125.625 x 4.907 2.D.315 42.1 x 32 3 O.D.1 x 25 3 O.1 88. x 51/2 O.4 63.0 4.3 2.0 154.0 1.-2 E to E O.2 0.1 x 165.7 6.500 x 4.375 114.500 x 3. x 2 76.268 5.1 x 50 3 x 11⁄2 80 x 40 76.1 x 42.5 0.2 30. x 11/2 76.1 4.1 8x6 200 x 150 219.4 4.900 114.9 1.5 0.0 153.495 5.375 63.2 21⁄2 x 11⁄4 65 x 32 2.D.814 6C 6 7 7 7 7 23.anvilintl.5 1.D.3 x 60.3 x 33.3 1.3 x 48. Ea.6 4 101.680 1.402 10.875 x 2.6 4.0 147.375 x 1.8 6./mm End Approx.996 3 76.0 All 7072i fittings are cast ductile iron.5 8.6 6.12 .6 1.948 5.0 1. 315 33.375 60.9 23 584 7 178 165 74.0 45. Ea.5 24 x 24 x 16 600 x 600 x 400 40 1016 10 254 725 329 12 x 12 x 8 For Listings/Approval Details and Limitations.6 6x6x2 150 x 150 x 50 14 356 41⁄2 114 33.D.9 81⁄2 216 31⁄4 83 11./Kg Nominal Size In.0 16. Lbs.1 3 x 3 x 2 ⁄2 1 8 ⁄2 1 3 ⁄4 1 11.0 18 x 18 x 12 450 x 450 x 300 32 4813 81⁄2 216 333 151 18 450 18.0 66.0 14 x 14 x 6 350 x 350 x 150 261⁄2 673 71⁄2 191 185 83.750 323.000 609.5 7.4 14 x 14 x 10 350 x 350 x 250 261⁄2 673 71⁄2 191 223 101 3 80 3.0 16 x 16 x 10 400 x 400 x 250 29 737 8 203 263 119 6 150 6./mm Approx.500 114.D.1 18 457 6 152 82.9 2 50 2./Kg Center to Long End In.6 18 x 18 x 14 450 x 450 x 350 32 813 81⁄2 216 358 162 20 500 20.4 29 737 8 203 345 157 8x8x6 200 x 200 x 150 18 457 6 152 75.3 7 178 23⁄4 70 4.2 14 x 14 x 4 350 x 350 x 100 26 ⁄2 1 7 ⁄2 1 173 78.000 406.625 219.5 8x8x5 200 x 200 x 125 18 457 6 152 68.2 14 x 14 x 12 350 x 350 x 300 26 ⁄2 1 7 ⁄2 1 240 109 318 673 191 31⁄2 90 4.5 0./DN(mm) Center to Long End In.0 4.5 2. Wt.2 11⁄4 32 1. Ea.com or contact an Anvil® Sales Representative.000 508.5 5.0 7.1 201⁄2 521 61⁄2 165 127 57.0 16 x 16 x 6 400 x 400 x 150 29 737 8 203 235 107 4 100 4.6 261⁄2 673 71⁄2 191 215 97.1 16 x 16 x 14 400 x 400 x 350 29 737 8 203 307 139 10 250 10./mm Approx.4 18 x 18 x 6 450 x 450 x 150 32 813 81⁄2 216 275 125 12 300 12.6 40 1016 10 254 940 426 10 x 10 x 6 250 x 250 x 150 201⁄2 521 61⁄2 165 105.0 4 x 4 x 2 ⁄2 1 10 ⁄2 1 3 ⁄4 3 17.750 273.0 5x5x2 125 x 125 x 50 12 ⁄2 1 4 102 22. Long End Short End Wt.8 4.8 18 x 18 x 10 450 x 450 x 250 32 813 81⁄2 216 321 146 16 400 16.000 355.0 35 889 9 229 517 235 10 x 10 x 5 250 x 250 x 125 201⁄2 521 61⁄2 165 100.0 15.6 4x4x2 100 x 100 x 50 101⁄2 267 33⁄4 95 15.0 18 x 18 x 8 450 x 450 x 200 32 813 81⁄2 216 306 139 14 350 14.3 8.4 18 x 18 x 16 450 x 450 x 400 32 813 81⁄2 216 382 173 24 600 24.2 32 813 81⁄2 216 425 193 10 x 10 x 4 250 x 250 x 100 201⁄2 521 61⁄2 165 83.6 21.0 13.0 5.500 88.0 20.com GL-7.6 20 x 20 x 12 500 x 500 x 300 35 889 9 229 390 177 10 x 10 x 8 250 x 250 x 200 201⁄2 521 61⁄2 165 116.5 8.8 16 x 16 x 12 400 x 400 x 300 29 737 8 203 283 128 8 200 8.900 48./mm Center to Short End In.1 20 x 20 x 16 500 x 500 x 400 35 889 9 229 440 200 12 x 12 x 6 300 x 300 x 150 23 584 7 178 140.0 62.0 47.6 10 254 31⁄2 89 14./mm In.660 42.anvilintl.3 14 356 41⁄2 114 46.6 6x6x4 150 x 150 x 100 14 356 41⁄2 114 40.4 6x6x5 150 x 150 x 125 14 356 41⁄2 114 45.625 168.8 8x8x4 200 x 200 x 100 18 457 6 152 59.7 14 x 14 x 8 350 x 350 x 200 26 ⁄2 1 7 ⁄2 1 195 88.5 13.1 6x6x3 150 x 150 x 80 14 356 41⁄2 114 37.8 16 x 16 x 8 400 x 400 x 200 29 737 8 203 250 113 5 125 5.3 121⁄2 318 4 102 30.D.563 141. Lbs.0 34.6 20 x 20 x 14 500 x 500 x 350 35 889 9 229 410 186 12 x 12 x 4 300 x 300 x 100 23 584 7 178 137.0 6. In./DN(mm) FIGurE 7070 rEducInG LAtErAL Nominal Size In.5 80 x 80 x 65 216 83 673 191 11⁄2 40 1.5 4x4x3 100 x 100 x 80 101⁄2 267 33⁄4 95 18. Wt. C to LE FIGurE 7069 LAtErAL Nominal Size In.2 53⁄4 146 21⁄2 64 2.3 101⁄2 267 33⁄4 95 18.12 59 .000 457. 7069 fiG. Ea.5 12.7 3x3x2 80 x 80 x 50 81⁄2 216 31⁄4 83 9. 7070 O.0 37.8 37.0 30. C to LE C to LE C to SE C to SE C to LE O.5 100 x 100 x 65 267 95 673 191 21⁄2 65 2.3 61⁄4 159 23⁄4 70 3.0 73⁄4 197 3 76 10./mm Center to Center to Approx.D.0 63. visit our website at www./mm Center to Short End In./Kg 1 25 1./DN(mm) O.5 10. 23 584 7 178 147.5 1.0 18.6 27. www.4 5x5x3 125 x 125 x 80 121⁄2 318 4 102 26.3 5x5x4 125 x 125 x 100 121⁄2 318 4 102 30.4 5 127 21⁄4 57 1.GruVLoK FIttInGS 45° Lateral 45° Reducing Lateral Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.7 24 x 24 x 20 600 x 600 x 500 40 1016 10 254 785 356 300 x 300 x 200 See Fitting Size chart on page 51 for O.000 101.anvilintl./mm Lbs. In.5 1. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.875 73.0 52.4 12 x 12 x 10 300 x 300 x 250 23 584 7 178 168 76. 0 27. Wt.8 74.3 3.8 0.6 9.4 45.D.3 1 25 1.2 11⁄4 32 1.0 75.000 101.2 151⁄2 394 81⁄2 216 234 106 10 x 10 x 3 10 x 10 x 4 10 x 10 x 5 10 x 10 x 6 10 x 10 x 8 61⁄2 61⁄2 61⁄2 61⁄2 61⁄2 61⁄2 7 7 7 7 7 7 201⁄2 201⁄2 201⁄2 201⁄2 201⁄2 201⁄2 521 584 584 584 584 584 584 521 521 521 521 521 457 197⁄8 203⁄4 217⁄8 227⁄8 271⁄4 271⁄4 203⁄4 21 ⁄2 23 ⁄4 603 660 711 787 546 20 500 20.0 61./mm 21⁄2 x 21⁄2 x 21⁄2 65 x 65 x 65 80 x 80 x 80 90 x 90 x 90 50 x 50 x 50 2x2x2 23⁄4 70 76 83 89 95 95 3 178 197 216 7 73⁄4 81⁄2 10 101⁄2 111⁄2 292 330 327 346 362 1 229 267 9 117 146 165 197 200 206 235 244 254 262 273 1 45⁄8 6.3 18 450 18.5 21⁄2 65 2.5 7. Lbs. FIG. 26 28 31 12 x 12 x 10 12 x 12 x 12 18 ⁄4 3 457 476 521 18 175 200 240 109 See Fitting Size chart on page 51 for O.000 609.000 457.000 508.4 11.2 23⁄4 70 21⁄2 64 1.com GL-7.875 73.0 9.1 5 125 5. Lbs.1 200 x 150 x 200 152 8 200 8.1 2.8 103⁄4 11 ⁄8 111⁄2 292 335 343 352 365 1 8x6x4 200 x 150 x 100 1 25 143⁄4 375 1 91⁄4 235 1 45./mm In. Long End Short End Wt.8 79.9 5.0 72./mm In.7 211⁄8 23 ⁄4 1 508 537 591 505 527 556 581 692 692 527 1 3 16 400 16.5 16.000 355.7 26.375 60.5 65. 201⁄2 60 www.5 10.0 61./DN(mm) G In.8 41⁄2 6 6 6 6 6 283 60.500 88. Wt.0 86.3 1.4 12 305 8 203 166.9 10 254 7 178 160./mm E1 In.315 33./mm Nominal Size In.9 50.D.4 49.0 20. 7066 – Tee Wye E1 O.660 42.4 21⁄4 57 21⁄4 57 1.3 11⁄2 40 1.2 4 100 4.4 90.gruvlok Fittings FIG.0 127⁄8 135⁄8 141⁄4 15 ⁄8 161⁄8 410 389 413 1 77⁄8 81⁄8 91⁄4 9 ⁄8 5 5x4x3 125 x 100 x 80 17⁄8 48 117⁄8 302 67⁄8 175 21.9 18./mm In. In.D.7 3x3x3 31⁄4 31⁄2 33⁄4 33⁄4 102 102 102 114 114 114 114 152 152 152 152 152 165 165 165 165 165 165 178 178 178 178 178 178 5x3x3 125 x 80 x 80 11⁄4 32 111⁄2 292 410 61⁄2 165 25.0 171⁄4 438 9 229 281 128 24 600 24.3 23⁄4 70 23⁄4 70 1.5 27.8 41⁄2 41⁄2 4 ⁄2 1 155⁄16 105⁄16 161⁄4 17 ⁄4 181⁄4 464 462 483 438 50 55 58 6x5x4 150 x 125 x 100 11⁄4 32 103⁄4 137⁄8 12 305 83⁄8 213 31.0 2.3 10 250 10.0 20.1 22.0 11.0 33⁄4 95 3 76 5./mm E2 In.8 6x4x6 6x5x3 150 x 125 x 80 41⁄2 11⁄4 32 14 356 181⁄4 111⁄2 13 330 352 61.8 68.anvilintl.5 4.3 61⁄2 165 41⁄2 114 21.000 406.com or contact an Anvil® Sales Representative.2 63.9 4x3x3 100 x 80 x 80 15⁄8 41 73⁄8 187 267 103⁄4 273 346 55⁄8 143 16.2 63.3 8x6x8 6 18 457 23 ⁄4 15 ⁄4 591 387 95. Ea. visit our website at www.563 141.3 5 127 33⁄4 95 10./mm Lbs.3 4 4 4 5x4x4 125 x 100 x 100 17⁄8 48 91⁄8 232 123⁄4 324 464 71⁄4 184 292 25. In.5 0.750 323.0 14.900 48.6 11 279 71⁄2 191 136.0 12.8 121⁄2 14 14 14 14 384 150 x 100 x 150 114 10 40 103⁄4 273 273 8 203 27./Kg FigurE 7071 truE WYE Nominal Size In.7 31⁄2 90 4.8 54.0 23.750 273.5 53⁄4 61⁄2 73⁄4 4x3x4 100 x 80 x 100 33⁄4 95 101⁄2 135⁄8 93⁄4 248 318 81⁄8 206 27.6 41⁄2 114 31⁄2 89 8.3 31⁄4 83 23⁄4 70 2.7 24./mm Center to Center to Approx.3 51⁄2 140 4 102 15 6.6 20 508 10 254 523 237 10 x 10 x 10 12 x 12 x 3 12 x 12 x 4 12 x 12 x 6 12 x 12 x 8 18 190 23 23 23 23 23 23 153⁄4 16 17 140 145 165 For Listings/Approval Details and Limitations. 7071 – True Wye C to LE O.D.1 73⁄4 197 6 152 36.9 41⁄4 108 31⁄4 83 6.1 18 18 18 18 18 183⁄16 133⁄16 19 20 131⁄2 137⁄8 143⁄8 15 ⁄4 147⁄8 151⁄4 153⁄4 161⁄8 191⁄4 489 457 400 406 432 410 400 387 378 387 100 110 111 112 120 130 135 140 145 150 12 300 12. H G E2 FIG./Kg O.12 ./DN(mm) FigurE 7067 rEDuCing tEE WYE Approx. 7067 – Reducing Tee Wye E1 O.0 7.6 14 350 14./DN(mm) G H E1 E2 Approx.anvilintl. Ea.0 43.4 6 150 6./mm H In.8 31⁄2 x 31⁄2 x 31⁄2 100 x 100 x 80 100 x 100 x 100 125 x 125 x 80 125 x 125 x 100 125 x 125 x 125 150 x 150 x 80 150 x 150 x 100 150 x 150 x 125 150 x 150 x 150 200 x 200 x 80 200 x 200 x 100 200 x 200 x 125 200 x 200 x 150 200 x 200 x 200 250 x 250 x 80 250 x 250 x 100 250 x 250 x 125 250 x 250 x 150 250 x 250 x 200 250 x 250 x 250 300 x 300 x 80 300 x 300 x 100 300 x 300 x 150 300 x 300 x 200 300 x 300 x 250 300 x 300 x 300 4x4x3 4x4x4 5x5x3 5x5x4 5x5x5 6x6x3 6x6x4 6x6x5 6x6x6 8x8x3 8x8x4 8x8x5 8x8x6 8x8x8 101⁄2 101⁄2 121⁄2 12 ⁄2 1 254 267 267 318 318 318 356 356 356 356 457 457 457 457 13 22 23 26 32 35 5x3x5 125 x 80 x 125 4 102 121⁄2 161⁄8 91⁄8 232 10 254 44.0 11.500 114.5 65.2 2.1 9 229 61⁄2 165 51.625 168.0 12.8 14. H E2 C to SE G FigurE 7066 tEE WYE Nominal Size In.3 3 80 3.1 0.4 11.625 219.0 16. Ea.0 10./mm In./Kg In.D.0 2 50 2.4 59.5 15.3 50. 6 0. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.7 21⁄2 65 2.7 2 50 2.3 1 25 1.875 73.625 168.0 6 150 6. 7087 Gr x fpt fiG.0 4 100 4.D.000 101.3 25⁄16 59 1./mm Nominal Size In.7 31⁄2 90 4. Lbs.7 1.500 114./mm Nominal Size In.0 2 50 2.875 73. 7055 Gr x mpt fiG.4 0.3 3 76 51⁄4 133 7.0 For Listings/Approval Details and Limitations.0 3 80 3.D.7 21⁄2 65 2. C to GE C to TE FIGurE 7087 FEMALE tHrEAd AdAPtEr Nominal Size In./mm Center to Grooved End In.7 11⁄2 40 1.5 11⁄2 40 1.1 5.6 0. 4 100 4.3 31⁄2 89 31⁄2 89 11.D.9 23⁄4 70 2.6 11⁄4 32 1.875 73.9 21⁄2 64 41⁄4 108 4.9 41⁄4 108 6 152 6. visit our website at www.7 0.2 25⁄16 59 1.5 1./mm End to End In./mm Approx.3 1.3 61⁄2 165 61⁄2 165 19.5 3.3 31⁄4 83 4./Kg Grooved End O.6 41⁄2 114 61⁄4 159 8.com or contact an Anvil® Sales Representative.7 21⁄2 65 2.5 2.6 23⁄4 70 23⁄4 70 4.anvilintl.2 1.5 2.315 33. In.3 21⁄2 64 1.5 0. Wt.3 1 25 1./Kg FIGurE 7056 45° AdAPtEr ELBoW Approx. Wt.0 21⁄4 57 21⁄4 57 2.2 3./mm Center to Threaded End In.com GL-7.625 168.375 60.900 48. Ea.4 13⁄4 44 13⁄4 44 0.0 – – 1.9 3 80 3.9 This product is not UL/ULC Listed or FM Approved.GruVLoK FIttInGS Female Thread Adapter 90° Adapter Elbow 45° Adapter Elbow Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs./DN(mm) Fitting O.315 33./DN(mm) Fitting O.3 11⁄4 32 1.2 1. www.3 13⁄4 44 13⁄4 44 0.900 48.3 31⁄4 83 41⁄4 108 2.anvilintl.6 0./mm Center to Grooved End In.4 2 50 2.D./DN(mm) FIGurE 7055 90° AdAPtEr ELBoW Approx.000 101./mm Center to Threaded End In.500 88. Lbs.3 2.500 88.375 60. C to TE O.3 5 127 71⁄4 184 11 5.500 88./Kg 1 25 1.375 60.D.0 31⁄2 90 4.500 114. Wt.315 33.660 42.0 33⁄4 95 33⁄4 95 3.5 11⁄4 32 1. In.1 3 80 3.D.8 9.660 42.0 4 100 4.900 48. O.2 0.4 21⁄4 57 21⁄4 57 0.2 13⁄4 44 13⁄4 44 0.4 6 150 6.660 42.500 114.4 21⁄16 52 0. Ea.7 0.6 0. In. 7056 Gr x mpt E to E C to GE O.3 2 51 3 76 1.8 0. Ea.2 23⁄4 70 23⁄4 70 1.6 0.0 0.3 23⁄4 70 23⁄4 70 1.12 61 . Lbs.3 11⁄2 40 1. GruVLoK FIttInGS reducinG base support elbow fiG. 7050rf – Grooved x 150# Flanged (GxF) Grooved flanGe nipples fiG. 7084 – Groove x Class 150 Flange Nipple fiG. 7085 – Groove x Class 300 Flange Nipple C to E E to E O.D. E to E O.D. H B Dia. FIGurE 7050 rF rEducInG BASE SuPPort ELBoW Nominal Size In./DN(mm) FIGurE 7084 GrooVE X cLASS 150 FLAnGE nIPPLE Approx. Wt. Ea. GxF Lbs./Kg FIGurE 7085 GrooVE X cLASS 300 FLAnGE nIPPLE Approx. Wt. Ea. Lbs./Kg Grooved End O.D. In./mm Center to End In./mm H In./mm B Dia. Threaded NPSC Nominal Size In./DN(mm) O.D. In./mm End to End In./mm End to End In./mm Approx. Wt. Ea. Lbs./Kg 6x4 150 x 100 6.625 168.3 12 305 21⁄2 64 11⁄2 38 38.5 17.5 1 25 1.315 33.4 3 76 2.5 1.1 3 76 3.6 1.6 6x5 150 x 125 6.625 168.3 121⁄2 318 21⁄2 64 11⁄2 38 45.4 20.6 11⁄4 32 1.660 42.2 4 102 3.8 1.7 4 102 4.6 2.1 8x5 200 x 125 8.625 219.1 16 406 3 76 11⁄2 38 65.5 29.7 11⁄2 40 1.900 48.3 4 102 4.1 1.9 4 102 7.1 3.2 8x6 200 x 150 8.625 219.1 16 406 3 76 11⁄2 38 73 33.1 2 50 2.375 60.3 4 102 6.0 2.7 4 102 8.2 3.7 10 x 6 250 x 150 10.750 273.1 19 483 3 ⁄2 1 1 ⁄2 1 100 45.4 21⁄2 65 2.875 73.0 4 102 9.2 4.2 4 102 11.9 5.4 89 38 10 x 8 250 x 200 10.750 273.1 19 483 3 ⁄2 1 1 ⁄2 1 127 57.6 3 80 3.500 88.9 4 102 10.4 4.7 4 102 15.5 7.0 89 38 12 x 8 300 x 200 12.750 323.9 22 559 4 102 11⁄2 38 155 70.3 31⁄2 90 4.000 101.6 4 102 14.0 6.4 4 102 21.0 9.5 4 100 4.500 114.3 6 152 19.1 8.7 6 152 28.0 12.7 12 x 10 300 x 250 12.750 323.9 22 559 4 102 11⁄2 38 186 84.4 5 125 5.563 141.3 6 152 23.0 10.4 6 152 35.0 15.9 This product is not UL/ULC Listed or FM Approved. 6 150 6.625 168.3 6 152 29.5 13.4 6 152 50.0 22.7 8 200 8.625 219.1 6 152 43.5 19.7 6 152 72.0 32.7 10 250 10.750 273.1 8 203 68.2 30.9 8 203 * * 12 300 12.750 323.9 8 203 96.1 43.6 8 203 * * 14 350 14.000 355.6 * * * * * * * * 16 400 16.000 406.4 * * * * * * * * 18 450 18.000 457.2 * * * * * * * * 20 500 20.000 508.0 * * * * * * * * 24 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. 24.000 609.6 * * * * * * * * 600 * Contact an Anvil Representative for dimensions & weights. This product is not UL/ULC Listed or FM Approved. 62 www.anvilintl.com GL-7.12 GruVLoK FIttInGS Cap Bull Plug Cross C to E Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 7074 fiG. 7075 fiG. 7068 E to E O.D. E to E O.D. O.D. FIGurE 7074 cAP Nominal Size In./DN(mm) FIGurE 7075 BuLL PLuG Approx. Wt. Ea. Lbs./Kg FIGurE 7068 croSS Nominal Size In./DN(mm) O.D. In./mm End to End In./mm Nominal Size In./DN(mm) O.D. In./mm End to End In./mm Approx. Wt. Ea. Lbs./Kg O.D. In./mm Center to End In./mm Approx. Wt. Ea. Lbs./Kg 1C 25 1.315 33.4 11⁄4 32 0.3 0.1 50 2 2.375 60.3 73.0 88.9 102 127 152 178 4 2.5 1.1 1.4 2.0 1 25 1.315 33.4 21⁄4 57 1.3 0.6 11⁄4 C 32 1.660 42.2 11⁄4 32 0.4 0.2 21⁄2 65 80 100 125 150 2.875 3.500 4.500 114.3 141.3 168.3 5 3.1 4.4 7.4 3.4 11⁄4 32 1.660 42.2 23⁄4 70 2.1 1.0 11⁄2 C 40 1.900 48.3 11⁄4 32 0.5 0.2 3 4 5 6 6 7 * * 11⁄2 40 1.900 48.3 23⁄4 70 2.5 1.1 2C 50 2.375 60.3 1 25 0.5 0.2 2 50 2.375 60.3 31⁄4 83 2.9 1.3 21⁄2 C 65 3 O.D. C 2.875 73.0 2.996 1 25 1 0.7 0.3 0.8 5.563 6.625 * * 21⁄2 65 2.875 73.0 33⁄4 95 5.2 2.4 76.1 3C 80 76.1 3.500 88.9 25 1 25 0.4 1.1 0.5 254 10 18.5 8.4 3 80 3.500 88.9 41⁄4 108 7.5 3.4 * Contact an Anvil Representative for dimensions & weights. This product is not UL/ULC Listed or FM Approved. 31⁄2 90 4.000 101.6 41⁄2 114 9.8 4.4 31⁄2 C 90 41⁄4 O.D. C 4.000 101.6 4.250 1 25 11⁄8 1.4 0.6 2.0 4 100 4.500 114.3 5 127 12.2 5.5 108.0 4C 100 51⁄4 O.D. C 108.0 4.500 114.3 5.236 29 11⁄8 29 11⁄8 0.9 2.8 1.3 3.2 5 125 5.563 141.3 51⁄2 140 17.6 8.0 6 150 6.625 168.3 61⁄2 165 28.3 12.8 133.0 51⁄2 O.D. C 133.0 5.500 29 11⁄8 1.5 4.0 8 200 8.625 219.1 73⁄4 197 48.0 21.8 139.7 5C 125 61⁄4 O.D. C 139.7 5.563 141.3 6.259 29 11⁄8 29 11⁄8 1.8 4.0 1.8 5.1 10 250 10.750 273.1 9 229 70.0 31.8 12 300 12.750 323.9 10 254 110 49.9 159.0 61⁄2 O.D. C 159.0 6.500 29 11⁄8 2.3 6.0 14 350 14.000 355.6 11 279 140 63.5 165.1 6C 150 165.1 6.625 168.3 29 15⁄16 33 2.7 6.0 2.7 16 400 16.000 406.4 12 305 170 77.1 18 450 18.000 457.2 151⁄2 394 260 118 8C 200 8.625 219.1 11⁄2 38 12.5 5.7 20 500 20.000 508.0 171⁄4 438 320 145 10 C 250 10.750 273.1 11⁄2 38 21.9 9.9 24 600 24.000 609.6 20 508 585 265 12 C 300 12.750 323.9 11⁄2 38 33.8 15.3 14* 350 14.000 355.6 81⁄2 216 40 18.1 16* 400 16.000 406.4 9 229 45 20.4 18* 450 18.000 457.2 10 254 58 26.3 20* 500 20.000 508.0 11 279 79 35.8 24* 600 24.000 609.6 121⁄2 318 100 45.4 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. * Machined Cap C - Cast Malleable or Ductile Iron www.anvilintl.com GL-6.11 63 GruVLoK FIttInGS nipples fiG. 7086 GR x HOSE Nipple fiG. 7080 GR x GR fiG. 7081 fiG. 7082 GR x MPT GR x BEV E to E O.D. O.D. E to E O.D. E to E O.D. E to E FIGurE 7086 HoSE nIPPLE Nominal Size In./DN(mm) FIGurES 7080, 7081 & 7082 AdAPtEr nIPPLE Approx. Wt. Ea. Lbs./Kg O.D. In./mm End to End In./mm Nominal Size In./DN(mm) O.D. In./mm End to End In./mm Approx. Wt. Ea. Lbs./Kg 1 25 1.315 33.4 31⁄4 83 0.4 0.2 1 25 1.315 33.4 3 76 0.4 0.2 11⁄4 32 1.660 42.2 35⁄8 92 0.7 0.3 11⁄4 32 1.660 42.2 4 102 0.8 0.4 11⁄2 40 1.900 48.3 4 102 0.8 0.4 11⁄2 40 1.900 48.3 4 102 0.9 0.4 2 50 2.375 60.3 45⁄8 117 1.3 0.6 2 50 2.375 60.3 4 102 1.2 0.5 21⁄2 65 2.875 73.0 51⁄2 140 2.1 1.0 3 80 3.500 88.9 6 152 3.3 1.5 21⁄2 65 2.875 73.0 4 102 1.9 0.9 4 100 4.500 114.3 71⁄4 184 5.5 2.5 3 80 3.500 88.9 4 102 2.5 1.1 5 125 5.563 141.3 93⁄4 248 8.1 3.7 31⁄2 90 4.000 101.6 4 102 3.1 1.4 6 150 6.625 168.3 11 279 13.2 6.0 4 100 4.500 114.3 6 152 5.5 2.5 8 200 8.625 219.1 121⁄2 318 24.0 10.9 5 125 5.563 141.3 6 152 7.4 3.4 10 250 10.750 273.1 14 356 29.0 13.2 6 150 6.625 168.3 6 152 9.5 4.3 12 300 12.750 323.9 16 406 46.0 20.9 8 200 8.625 219.1 6 152 14.2 6.4 This product is not UL/ULC Listed or FM Approved. 10 250 10.750 273.1 8 203 27.0 12.2 12 300 12.750 323.9 8 203 33.0 15.0 This product is not ULC Listed. For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. 64 www.anvilintl.com GL-7.12 GruVLoK FIttInGS Bullhead Tee (GR x GR x FPT) Standpipe Tee (GR x GR x FPT) Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 7062 fiG. 7065 C to EOR O.D. O.D. C to EOB C to EOB C to EOR FIGurE 7062 BuLLHEAd tEE (Gr x Gr x FPt) Nominal Size In./DN(mm) FIGurE 7065 StAndPIPE tEE (Gr x Gr x FPt) Approx. Wt. Ea. Lbs./Kg Center to End of Run In./mm Center to End of Branch In./mm Nominal Size In./DN(mm) O.D. In./mm Center to End of Run In./mm Center to End of Branch In./mm Approx. Wt. Ea. Lbs./Kg 5x5x8 125 x 125 x 200 73⁄4 197 51⁄2 140 31.0 14.1 4 x 4 x 21⁄2 100 x 100 x 65 4.500 114.3 31⁄4 83 4 102 7.6 3.4 6x6x8 150 x 150 x 200 73⁄4 197 61⁄2 165 37.6 17.1 6 x 6 x 21⁄2 150 x 150 x 65 6.625 168.3 31⁄4 83 51⁄8 130 11.2 5.1 See Fitting Size chart on page 51 for O.D. These fittings are designed to provide minimal pressure drop and uniform strength. Pressure ratings of Gruvlok Fittings conforms to those of Fig. 7001 Gruvlok Standard Coupling. For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. See Fitting Size chart on page 51 for O.D. These fittings are designed to provide minimal pressure drop and uniform strength. Pressure ratings of Gruvlok Fittings conforms to those of Fig. 7001 Gruvlok Standard Coupling. fiG. 7050dr 90° Drain elbow Nominal Size In./DN(mm) FIGurE 7050dr 90° drAIn ELBoW O.D. In./mm Max Working Pressure PSI/bar Dimensions C to E In./mm H In./mm Approx. Wt. Ea. Lbs./Kg 1 ⁄4 1 1.660 42.2 300 20.7 2 ⁄4 3 1 ⁄4 3 0.7 0.3 32 69 44 11⁄2 40 1.900 48.3 300 20.7 23⁄4 69 13⁄4 44 1.7 0.8 C to E O.D. H 2 50 2.375 60.3 300 20.7 31⁄4 83 13⁄4 44 2.0 0.9 21⁄2 65 2.875 73.0 300 20.7 33⁄4 95 17⁄8 48 2.5 1.1 3 80 3.500 88.9 300 20.7 41⁄4 108 2 51 3.2 1.5 4 100 4.500 114.3 300 20.7 5 127 21⁄4 57 4.6 2.1 5 125 5.583 141.3 300 20.7 51⁄2 140 23⁄8 60 11.5 5.2 6 Available fabricated Schedule 10 only. Drain elbow has a standard 1" female NPT outlet. 150 6.625 168.3 300 20.7 61⁄2 165 23⁄8 60 9.6 4.4 8 200 8.625 219.1 300 20.7 73⁄4 197 21⁄2 64 15.8 7.2 10 250 10.750 273.1 300 20.7 9 229 23⁄4 69 48.5 22.0 12 300 12.750 323.9 300 20.7 10 254 23⁄4 69 66.0 29.0 www.anvilintl.com GL-7.12 65 GruVLoK FIttInGS Gruvlok® fire-rite™ short pattern fittinGs fiG. 7450 90° Short Pattern Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. The Gruvlok® Fire-Rite™ short pattern 90° elbows has a 2" to 8" size range and a 300 psi pressure rating. Fire-Rite™ fittings are painted to industry specification and are available galvanized for more corrosive environments. CAD design increases internal diameters and provides superior flow capability. FIGurE 7450 90˚ ELBoW SHort PAttErn FIttInG – PrESSurE droP 18 C TO E O.D. FIGurE 7450 90° ELBoW Nominal Size In./DN(mm) Pressure Drop (ft. of Schedule 40 pipe) 16 14 12 10 8 6 4 2 0 5 10 15 20 8 inch 6 inch 4 inch 3 inch 21/2 inch 2 inch O.D. In./mm Center to End In./mm Approx. Wt. Ea. Lbs./Kg 2 50 2.375 60.3 23⁄4 70 1.7 0.8 21⁄2 65 2.875 73.0 3 76 2.6 1.2 3 80 3.500 88.9 33⁄8 86 3.5 1.6 4 100 4.500 114.3 4 102 6.5 3.0 Flow Rate (ft./sec.) Gruvlok short pattern fittings exceed the headloss requirements of NFPA 13. For Fig. 7450 90˚ grooved end elbows use the value shown. Note: Above values are shown for Schedule 40 pipe to be consistent with industry practices. 6 150 6.625 168.3 51⁄2 140 14.8 6.7 8 8.625 67⁄8 175 25.6 11.6 200 219.1 All are Ductile Iron. fiG. 7460 Short Pattern Tee The Gruvlok® Fire-Rite™ short pattern tee has a 2" to 8" size range and a 300 psi pressure rating. Fire-Rite™ fittings are painted to industry specification and are available galvanized for more corrosive environments. CAD design increases internal diameters and provides superior flow capability. FIGurE 7460 tEE SHort PAttErn FIttInG – PrESSurE droP 18 C TO E O.D. C TO E Pressure Drop (ft. of Schedule 40 pipe) 16 14 12 10 8 6 4 2 0 5 10 15 20 8 inch 6 inch 4 inch 3 inch 21/2 inch 2 inch FIGurE 7460 tEE Nominal Size In./DN(mm) O.D. In./mm Center to End In./mm Approx. Wt. Ea. Lbs./Kg 2 50 2.375 60.3 23⁄4 70 2.5 1.1 21⁄2 65 2.875 73.0 3 76 3.5 1.6 3 80 3.500 88.9 33⁄8 86 4.8 2.2 Flow Rate (ft./sec.) 4 100 4.500 114.3 4 102 8.1 3.7 Gruvlok short pattern fittings exceed the headloss requirements of NFPA 13. For Fig. 7460 Tee branch use 21/2 times the value shown. For Fig. 7460 Tee run use the value shown. Note: Above values are shown for Schedule 40 pipe to be consistent with industry practices. 6 150 6.625 168.3 51⁄2 140 19.1 8.7 8 8.625 67⁄8 175 35.2 16.0 200 219.1 All are Ductile Iron. 66 www.anvilintl.com GL-7.12 6. Grade B.6 7./Kg Approx.9 227.8 675.7 150./mm FIG.D./DN(mm) FIG.7 80. 7052-3D.6 40.2 490.12 67 .4 4.0 227.0 120.3 15.3 560.4 39./mm FIG. 5.9 378. Material: standard wall steel pipe to ASTM A 53.8 323⁄4 381⁄4 433⁄4 1111 1251 1391 1664 27 213⁄4 552 641 737 191⁄4 489 572 648 730 813 151⁄2 394 464 527 593 660 787 327.3 73 254 10 5.3 373.7 11.1 164.3 87.8 43⁄4 5 5 4.2 304.000 24.com GL-7.0 18.0 401⁄2 1029 1143 321⁄2 826 914 336.0 194.3 219. 45° Elbow Fig. 7051-3D. 8" through 16" ± 1⁄4" (6./Kg Approx.7 879.6 148./Kg 50 2 2.8 115.4 165 184 197 216 229 61⁄2 71⁄4 73⁄4 81⁄2 9 3.3 141.3 601.3 6.35 26 31 36 363.3 14.5 212.6 2.8 98.1 135.2 3 13 61⁄2 63⁄4 71⁄4 9 6.0 31⁄2 90 100 125 150 200 250 300 350 400 450 500 600 4.1 467.1 123⁄4 324 406 60.9 146.9 103⁄4 273 368 457 91⁄2 141⁄2 18 68.1 323.3 82.4 91. Wt.7 491⁄4 543⁄4 651⁄2 544.4 297.9 15.3 311⁄2 800 914 251⁄4 29 221⁄2 251⁄2 283⁄4 32 181⁄4 203⁄4 23.9 1.D.7 6.4 4.5 2. R=3 O. 7057-3d 60° ELBoW Approx.5 12.375 60. Wt.3 5.4 3.4 30.7 9.9 18.5 12. Lbs.6 188.6 246.7 37.000 609.5 177.563 6.3 576.5 5.8 226.0 1270.D.0 4. 30° Elbow Fig.4 18.9 193. Bends to conform to above radii.8 9.6 71. Remaining sizes are provided with integral tangents with lengths equal to the nominal pipe size.625 8.000 16.6 11./Kg Approx.2 22. 7053-3D.3 398.9 222.1 124.3 128.3 103. Lbs. Wt.0 7.5 441. 111⁄4° Elbow FIGurE 7050-3d 90° ELBoW Nominal Size In./mm FIG.4 102.0 18.625 10.2 11.3 429.8 21.1 322.1 146 152 165 171 184 229 53⁄4 6 3.6 141⁄2 368 406 508 610 813 1016 1219 1422 1626 1829 2032 2438 4 5 6 8 4.1 273.4 78. O.0 274.4 254. Ea.1 171.2 7.0 3.6 24. 7057-3D. 221⁄2° Elbow Fig.5 107. 7053-3d 111⁄4° ELBoW Center to End In.D. Ea.8 254. In. 3D long radius elbows are available in sizes up to 24". C to E tolerances: 2" through 6" ± 1⁄8" (3.000 18.5 202. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.3 152.8 54.5 2.6 97. Wt. Lbs. O.2 508 16 20 24 32 40 48 56 64 72 80 96 61⁄2 8 51⁄4 61⁄2 73⁄4 5.1 2.2 1.000 20.2 mm). R =3 O.9 58. Ea.9 5.7 427. Lbs.anvilintl. Sizes 4" and below are provided with a 4" (101. (Other materials available on request).5 131⁄2 18 41.5 8.2 74. Ea. Lbs.GruVLoK FIttInGS Long Radius Elbows Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs./mm O. Grooved or plain-end available .3 10 12 14 16 18 20 24 271⁄4 692 832 972 221⁄2 572 686 16 13 332.0 10.9 63. 18" through 24" + 3⁄8" (9.4 45 36 339.4 1. Wt. 7052-3d 221⁄2° ELBoW Center to End In.2 157.5 31.5 mm).8 33. Wt.specify choice on order.8 216.3 168.D.2 8.1 44.1 10.5 973.1 710.3 15.6 28.8 114 121 127 127 133 165 197 41⁄2 2.6 3. Lbs.6 406.3 9. 7050-3D.1 13.500 114.6 mm) long integral tangent.4 457. 60° Elbow Fig.3 164.9 305.6 4.5 461.8 24.9 215. R=3D D R= 3D 3D Fig. 7050 3d 1.3 5.9 209.6 58.4 19.6 66.3 153.3 2.9 111⁄2 292 330 9.D.8 97. 2.4 191 210 235 254 279 71⁄2 81⁄4 91⁄4 10 11 4.750 12.D.4 30./mm Center to End In.2 120.7 26.4 mm).2 22.8 272.4 48. All weights are approximate.3 7. D R=3D O. based on calculated weight of pipe.2 12.000 101. 7058-3d 30° ELBoW Center to End In.500 88.2 7.4 133⁄4 349 419 559 111⁄4 286 343 457 161⁄2 22 48.7 127.3 4. 7058-3D./mm Center to End In.7 824.0 14.2 533⁄4 1365 431⁄4 1099 381⁄4 972 www./mm Approx. 4.9 173.6 5.4 8.6 9.8 8. Ea.3 103. 90° Elbow Fig.3 21⁄2 65 80 2.2 245.8 101⁄2 267 330 49.9 133 140 146 152 165 203 241 51⁄4 51⁄2 53⁄4 6 3./Kg FIG.8 1.5 14.875 3.3 540. Ea.2 5.5 416.3 265.8 3.7 27.8 3. 3.750 14.0 6.4 673./Kg Approx.9 355.3 2. 7051-3d 45° ELBoW Center to End In. R= O. 0 11.9 473.8 45.8 133.6 2. 8" through 16" ± 1⁄4" (6.000 609.6 2.5 127 133 140 146 152 191 229 305 381 457 533 610 686 762 5 3.9 355.7 244.3 494.9 70.2 3.1 323.8 9.3 21⁄2 65 80 2.2 112.com GL-7.0 605.4 150.3 284. Wt.000 20.500 5.7 519.1 51⁄4 51⁄2 53⁄4 6 5.8 274.9 5.3 73 356 14 7. 7051-5D 45° ElBoW Center to End In./Kg Approx.12 .D. 6.3 24. 2.9 7.7 14 43.6 75.6 24 30 36 48 60 72 84 96 35.6 137./Kg Approx.3 773⁄4 1975 2369 463⁄4 561⁄4 931⁄4 353⁄4 908 68 www.5 8.0 1.7 113⁄4 298 356 10 12 16 20 24 28 32 36 40 48 71⁄2 9 56.8 189.3 12.7 390.1 10. Ea.1 12.1 110. 7052-5D.5 187.0 5. Grooved or plain-end available. O.D.D.5 4.0 9.2 183⁄4 476 597 711 12 15 18 21 24 27 30 56.anvilintl. Ea.3 377.2 90. 5.000 18.7 133. based on calculated weight of pipe. 7050 5D Long Radius Elbows 1.6 114. Wt.4 235.6 776.4 mm).6 mm) long integral tangent.6 1./DN(mm) Fig.4 25.1 108 120 144 551⁄4 611⁄2 733⁄4 315.6 323⁄4 832 953 294./mm Approx.7 171 191 203 222 241 63⁄4 71⁄2 8 4.864.0 20.0 273.1 3 19 123⁄4 121⁄4 151⁄2 191⁄2 231⁄4 31 39 101⁄4 260 286 318 394 470 622 781 940 1092 31⁄2 90 100 125 150 200 250 300 350 400 450 500 600 4.4 252.gruvlok Fittings FIG.2 3.375 60.1 16.9 39.8 112.2 750.1 3.2 508 211⁄2 546 610 762 914 1219 1524 1829 2134 2438 2743 3048 3658 111⁄4 121⁄2 151⁄2 181⁄2 241⁄2 303⁄4 37 43 83⁄4 91⁄2 71⁄2 8 4 5 6 8 4.8 4. 4. Lbs./mm Fig.2 1.2 16.4 457. Ea. R=5 O.3 114.290. 7050-5D.0 16.3 219.750 12. 3. (Other materials available on request).5 845.1 273.7 7.8 2.7 10. 7053-5D.750 14.2 171.4 1.3 3.1 224.2 mm). 18" through 24" + 3⁄8" (9.2 15.2 508.0 26. 221⁄2° Elbow Fig. Ea.8 248. 111⁄4° Elbow FigurE 7050-5D 90° ElBoW Nominal Size In. Lbs.9 12.6 67.7 196. 45° Elbow Fig.7 419.4 2.5 mm).2 4.121.2 256. 60° Elbow Fig.6 332.5 430.7 603. Wt.1 27.1 541⁄2 621⁄4 70 460.0 93./Kg 50 2 2.8 20./mm Fig.8 766.4 174.7 61⁄2 7 6.1 210 235 81⁄4 91⁄4 4.D.5 51./mm Fig.4 627. Ea.6 162.000 16. Wt.9 293.D. All weights are approximate.8 11. C to E tolerances: 2" through 6" ± 1⁄8" (3. R=5D D R= 5D 5D Fig.000 24. R= O.0 6.1 6.5 627.9 155. R =5 O.9 491⁄4 1251 1403 1562 1873 371⁄2 421⁄4 1073 1187 1429 330.2 42.3 36.0 190.6 564. 7057-5D.5 21. Remaining sizes are provided with integral tangents with lengths equal to the nominal pipe size.4 822. Sizes 4" and below are provided with a 4" (101.8 221.1 111⁄4 286 324 311 394 495 591 787 991 10.9 8. Bends to conform to above radii. Grade B.2 28.4 133./Kg Approx.5 152 165 178 191 203 254 305 406 508 610 711 813 914 1016 1219 6 3.0 31.6 89./Kg Approx.6 6.7 352. Lbs.9 44. D R=5D O.D. Lbs./mm Center to End In. 7058-5D.0 621.9 143. Wt.9 347.4 85.D.0 10. 5D long radius elbows are available in sizes up to 24".0 873. Ea.6 406.2 8.9 103.9 26.3 585. Lbs.7 19. 7053-5D 111⁄4° ElBoW Center to End In.6 12. 7051-5D.6 147.9 1.8 3./mm Center to End In.8 463⁄4 1187 1384 1581 1778 358.1 62.6 372.2 947.3 19.3 489.0 1.4 60.4 37. O.8 87.0 248 93⁄4 5.9 8. 30° Elbow Fig.5 16.0 86.8 25.7 7.563 6.625 10.3 168.875 3./Kg Fig.4 1.625 8.9 17.000 101.0 13.0 385.369.8 228.5 340. 7057-5D 60° ElBoW Approx.4 150.8 199. Wt. 7058-5D 30° ElBoW Center to End In.5 284.3 14.8 100.9 161⁄2 419 483 13./mm O.1 68.9 4. In.7 18.9 1.043.2 177.6 28.1 34.5 5.2 60. Lbs. Material: standard wall steel pipe to ASTM A 53.500 88.3 141.0 10 12 14 16 18 20 24 231⁄2 28 488.3 6.4 396.7 209. 7052-5D 221⁄2° ElBoW Center to End In.8 221. 90° Elbow Fig.5 9. D. D R=6D O.000 101.1 323. 7057-6D. 6D long radius elbows are available in sizes up to 24".2 7. O.750 14./mm Approx./Kg fig.8 254.8 31⁄2 90 100 125 150 200 250 300 350 400 450 500 600 4.3 5.4 18.8 256.0 18.750 12.D.500 114. R =6 O.8 531⁄2 621⁄2 711⁄2 801⁄2 891⁄4 1071⁄4 410.D./mm fig.5 527. Sizes 4" and below are provided with a 4" (101.9 5./mm Center to End In.8 164.7 221⁄4 565 679 908 171⁄2 445 533 711 889 40.2 1. Wt.9 173.0 3.6 148.5 14.1 13.270.162.anvilintl.8 576.5 441.1 133 140 146 152 165 203 241 51⁄4 3.9 305.8 3.085.4 165 178 191 210 222 279 61⁄2 7 3.6 mm) long integral tangent.7 127./Kg Approx.1 1.7 11.625 8. Material: standard wall steel pipe to ASTM A 53.2 11.6 28.D. 221⁄2° Elbow Fig. Wt.2 157.5 202.2 311⁄4 794 927 261⁄4 667 781 895 483⁄4 553⁄4 623⁄4 693⁄4 833⁄4 427. 5.4 4.6 71.4 174.8 272.6 188. Lbs. Grade B.2 508 609.1 41.1 10.3 1.8 50./Kg Approx. 7051-6D. 30° Elbow Fig.4 457.6 157.8 226.8 3 22 141⁄2 161⁄4 18 111⁄2 123⁄4 14 83⁄4 93⁄4 71⁄2 81⁄4 83⁄4 11 7.3 152. Wt.3 265. Wt.4 673.4 91.3 361⁄2 413⁄4 1060 1194 327.3 691. based on calculated weight of pipe.9 251⁄2 283⁄4 313⁄4 381⁄4 47 544.4 8.4 102. 6. O.3 1.3 429.500 88. Lbs./Kg Approx.3 125.4 48.9 193.7 26.5 31.D. C to E tolerances: 2" through 6" ± 1⁄8" (3.3 15.000 16.7 13 263⁄4 353⁄4 443⁄4 1137 1359 1588 1816 2045 2267 2724 21 28 35 153⁄4 400 533 660 48.4 17.2 98.6 246. R=6D D R= 6D 6D Fig. Ea.5 973.2 313. 3. (Other materials available on request). Lbs.3 6.9 1.4 78. Lbs. 7057-6D 60° ElBoW Approx.8 97.6 66.2 22.6 678. 60° Elbow Fig.2 8. Wt.8 492.6 49. 7053-6D 111⁄4° ElBoW Center to End In.1 877.1 44.7 6.2 239. 4. R= O.9 373.1 322. Bends to conform to above radii. Lbs.5 397.9 355.1 273.3 2.496./mm Center to End In. 8" through 16" ± 1⁄4" (6. 2.3 168.6 24.0 22.4 140 168 521⁄4 1327 1588 44 570.567. Lbs.8 115. Ea.6 97.0 4.2 727.4 19.9 51⁄2 53⁄4 6 5.5 416. 7051-6D 45° ElBoW Center to End In.7 879.9 10.0 101⁄2 267 330 61⁄2 8 5.5 12.2 22.6 28 35 42 56 70 84 98 29.3 4.5 5.3 303⁄4 351⁄4 391⁄2 1003 1118 221⁄4 565 648 730 806 972 112 126 363.3 219.9 277.000 20 24 69.875 3. Ea. Grooved or plain-end available.4 953.4 mm).3 14.0 18.34 1329 www. Ea. 7052-6D. 18" through 24" + 3⁄8" (9.5 78.000 18.7 186.6 25 31.7 229 9 5. 45° Elbow Fig.12 69 .7 9.0 336.4 14.3 209. 7052-6D 221⁄2° ElBoW Center to End In. R=6 O.2 120.4 254.7 1.5 107.5 101⁄4 260 292 324 356 9.gruvlok fittings Long Radius Elbows Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories FIG.6 406.1 1.4 398.7 621⁄2 52.5 385.209. In.4 126.4 30./Kg Approx.2 258.3 141.1 710.0 980.9 35.9 18.com GL-7. All weights are approximate.9 146.9 279 11 6./DN(mm) fig.6 7. 7058-6D.375 60. 7058-6D 30° ElBoW Center to End In.3 601. 7050 6D 1.7 150.3 13.9 432.4 184 203 222 248 71⁄4 8 4.5 mm).6 108.9 58.9 91⁄2 21 26 171⁄2 22 123⁄4 324 406 483 60.0 7.D.4 2.5 413⁄4 1060 1238 1416 1594 1772 2127 332.3 560.625 10.0 194. 7053-6D.8 329.2 5.D.4 548. 7050-6D.3 82. Remaining sizes are provided with integral tangents with lengths equal to the nominal pipe size.9 215.5 131⁄4 337 445 559 41.6 31.3 2.4 3.3 9.9 19 15.4 217.5 8.5 22.8 10.1 18. 111⁄4° Elbow figurE 7050-6D 90° ElBoW Nominal Size In.8 10 12 14 16 18 20 24 16 19 566.9 63.3 2. 90° Elbow Fig./mm O.7 27.2 711.7 279. Ea.5 21⁄2 65 80 2.7 37.5 461.7 824.7 6. Wt.0 14.2 mm).7 4 5 6 8 4.2 3./mm fig./mm fig.0 6.5 12./Kg 50 2 2.3 73 406 483 559 635 711 889 1067 1422 1778 2134 2489 2845 3200 3556 4267 16 8.3 2. Ea.7 71.563 6.1 123⁄4 324 368 413 457 11. For data on fire protection listings/approvals. The high strength. The stem sealing force is constant through the full disc cycle and operating torques are kept low which increases valve life.VALVES And AccESSorIES series 7700 Butterfly Valve an-7721-3 Series 7700 butterfly valve with 10 position lever lock an-7722-3 Series 7700 butterfly valve with gear operator Used in commercial grooved-end piping systems 2" through 12".com GL-6. stainless steel stems are blow-out proof. 2" . The design provides a bubble tight seal from full vacuum to 300 psi when the valve is closed.anvilintl. The valve body is a rugged one-piece casting with an integral mounting base for gear operator or handle actuation. NSF/ANSI 61 The stem-to-disc connection provides zero backlash. The Series 7700 valve is designed with the contractor in mind. The valve is designed and manufactured to meet or exceed the requirements of MSS SP-67. contact your Anvil representative. The valve is rated for dead-end service to a full pressure rating of 300 psi.11 . while providing room for a minimum of 2" of pipe insulation. This facilitates a constant DISC-TO-SEAT loading that maintains a leak tight stem seal regardless of disc position. Each stem is fitted with a secondary seal that also provides a lifetime lubrication chamber. The uniqueness of the Series 7700 Gruvlok Butterfly Valve begins with the spherical bore of the disc seat area.10" Series 7700 Certified to NSF/ANSI 61 (cold water) and Annex G 70 www. corrosion resistant. com GL-6. L/Lock 2 . ❏ Grade E (EPDM): Service Temperature Range -40°F to +230°F (-40°C to +110°C) Recommended for water service. oil-free air and many chemical services.Short 10 Pos.Nitrile (Grade T) 2 . air with oil vapors. NOT FOR USE IN HOT WATER SERVICES. Grade 65-45-12 Body Coating: Nylon: +230°F (+110°C) maximum service temperature DISC: Ductile Iron conforming to ASTM A 536 Grades 65-45-12 Disc Encapsulation: Properties as specified in accordance with ASTM D 2000. 10". www. E. hand levers on 10" and 12" valves are not available. alkalies. For operator safety. ❏ Grade T (Nitrile): Service Temperature Range -20°F to +180°F (-29°C to +82°C) Recommended for petroleum products. NOTE: For operator safety.Silicone Free GruVLoK ButtErFLY VALVE SErIES 7700 (ordErInG InForMAtIon) Sample Part Number 8" AN7721-3* ––> 8" Size 2" .VALVES & AccESSorIES Butterfly Valve Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.anvilintl. BODY: Ductile Iron conforming to ASTM A 536.S. 4.10 Pos.416 S. 2. dilute acids. 7. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories series 7700 material specifications 1.11 71 .EPDM (Grade E) 0 .12" A A Body Style N Body Coating N . vegetable oils and mineral oils.None 1Operator 1 . NOT FOR USE IN PETROLEUM SERVICES.Infinite Pos. hand levers on 8" valves are limited to applications with a 25 PSI (1.Nylon 77 Series 77-77XX 2 Disc Coating 1 . w/Memory Stop 4 . L/lock Operator 3* Stem 3 . TOP AND BOTTOM BRONzE SLEEVE BUSHINGS: 8".7 bar) maximum pressure. 3. UPPER AND LOWER SHAFT: Type 416 Stainless Steel 5.Gear Operator D . O-RINGS: Compatible with disc coating 6. & 12" Valve only 5 3 6 7 1 2 7 5 4 * Special Options Call an Anvil Representative for pricing and availability. 1 4 102.0 5 127.1 11.2 3 76.2 7 5 127.3 5 127.1 11.0 2 51.D.0 ⁄16 ⁄16 - ⁄16 ⁄16 - ⁄16 ⁄16 - ⁄16 ⁄16 - ⁄8 ⁄8 1 25.anvilintl.1 11.7 101⁄2 266.3 1013⁄16 275.0 53⁄8 136.2 3 76.9 7 11⁄16 26.5 115⁄8 295.3 65⁄16 160.8 8 202.0 5 127.2 7 22.8 73⁄4 196.1 19.1 3 75.7 15 381.1 4 102.2 61⁄2 165.3 1013⁄16 275.5 5 126.9 7 15⁄8 41.3 811⁄16 221.5 81⁄16 204.9 615⁄16 175.1 4 102.0 5 127. In.1 11.9 7 11⁄16 26.9 9 229.0 25⁄8 66.3 65⁄16 160.0 25⁄8 66.5 51⁄2 138.2 11⁄2 38.2 5 127.1 123⁄4 323.6 51⁄4 133.1 3 15⁄8 41.0 31⁄2 88.0 31⁄4 83.5 2 51.1 3.1 19.4 10 253.9 7 11⁄16 26.7 101⁄2 266.2 Note: 3" or 5" handwheels may be included on valves sizes 2" .0 12 304.7 101⁄2 266.9 41⁄2 114.8 61⁄2 165.3 65⁄16 160.2 11⁄2 38.3 101⁄2 266.5 13⁄8 34.0 5 127.0 313⁄16 96.1 1 13.3 51⁄16 129.7 91⁄2 241.4 63⁄8 161.2 9 3 76.6 71⁄2 191.2 9 3 76.1 11.0 2 51.0 5 127.5 29⁄16 65.3 65⁄16 160.3 65⁄16 160.2 9 3 76.3 7 14./mm 23⁄8 60.7 101⁄2 266.1 11.0 5 127.VALVES And AccESSorIES series 7700 Butterfly Valve SErIES 7700 ButtErFLY VALVE dIMEnSIonS Dimensions In.2 7 3 76.3 7 14.9 7 11⁄16 26.5 13.5 25⁄16 58.7 11⁄16 26.8 12 304.2 165⁄8 422.4 33⁄16 80.9 A B C D E F G H J K L M N P R S T U 33⁄16 81.0 2 51.8 18 457. Contact your Anvil Rep.3 59⁄16 141.8 45⁄8 117.8 313⁄16 96.9 43⁄8 111.3 7 22.0 55⁄16 135.0 65⁄16 160.3 513⁄16 147.2 3 76.com GL-6.7 101⁄2 266.4 43⁄16 105.0 5 127.1 4 102.2 11⁄2 38.2 11⁄2 38.5 41⁄4 108.3 85⁄8 219.2 7 ⁄16 - ⁄16 ⁄8 ⁄2 ⁄2 ⁄2 11.3 65⁄8 168.0 8 203.9 91⁄2 240.1 3 76.0 97⁄16 240.4".6 513⁄16 147.0 5 127.1 81⁄16 204.8 1 11⁄4 31.0 2 51.1 3 15⁄8 41.8 1 14.1 11.8 313⁄16 96.4 61⁄4 158.4 11⁄2 38.9 1415⁄16 379.1 11. 72 www.5 13.11 .2 3 76.4 1 11⁄4 31.1 19.5 61⁄4 158.1 11.0 - - 713⁄16 198. for additional information.3 3 76.0 5 127.1 4 102.1 51⁄2 140.9 7 178.1 9 228.9 7 11⁄16 26.2 11⁄2 38.3 7 14.0 23⁄4 70.3 27⁄8 73.7 2011⁄16 525.3 1313⁄16 350.2 3 76.0 2 51.1 3 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄16 ⁄4 ⁄4 ⁄4 11.3 - - 101⁄2 266.2 9 3 76.3 4 102.7 57⁄8 149.1 103⁄4 273.8 17⁄8 47./mm Valve Size (ANSI/DN) 2 50 21⁄2 65 3 80 4 100 5 125 6 150 8 200 10 250 12 300 O.2 25⁄16 58.1 11. 500 114.625 168.0 4.1 21⁄2 65 3 80 3.2 51.8 - 4.3 11.3 1.100 75.6 2./mm HEAdLoSS EQuIVALEnt LEnGtH oF PIPE 60° 48 3.563 6.7 90° 158 10.452 164.5 75 9.anvilintl.750 323.1 1.Sizes 2" thru 12") Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.260 224.6 85 9.3 25.5 5.0 34 2.D.6 14 1.9 5.625 219. In.4 755 52.3 8 200 8.920 132.0 4.3 - 31⁄2 90 * The equivalent feet of pipe is based on the Hazen and Williams formula and the flow rates typically used with each size valve.6 404 48.410 235.4 10 250 10.9 252 17.5 2.962 135.500 88.6 7.7 12 300 12.3 29 2.8 1.7 128 8.9 273.4 112 7.440 99.5 250 17.0 582 40.680 189.3 5 7.825 125.8 97.500 5.8 196 13.7 99.4 50 3.7 36.500 114. 10 Sch.2 CH 78.5 1.3 62 4.3 88.590 247.633 297.3 2.8 VA LV E H VA LV E 21⁄2 2. * Weights may vary based on valve options selected. 0.9 - 7. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories series 7700 cV VALuES Valve Size In.0 41 2.4 2 50 21⁄2 65 2.8 2.875 10 75 82 82 90 94 21 /2 IN CH 3I VA NC LV H E VA LV E 50 2 2.0 70° 80 5.6 141 9./mm Disc Position (degrees open) 25° 4 0.VALVES & AccESSorIES Butterfly Valve Performance Data Maximum Working Pressure Rating: 300 PSI (Commercial Applications .750 323.3 10.8 1.3 11 15 20 46 68 78 91 8.9 73.8 142 9.4 89.5 415 28.2 39.1 1.5 3.9 0.625 219.875 73.350 231.750 273.0 9 0.1 CH 0.3 6.0 3.6 792 54.3 114.7 1.4 41.6 864 1.6 - 3.6 13.8 1.7 780 53.9 - 4.4 2.1 4./m Max.5 376 45.370 94.5 5.1 809 55./mm O.7 21⁄2 65 5 125 5.460 100.3 3.5 2.590 316.8 4.2 347 24.9 Valve Size In.3 8.3 96 6.7 1.6 6 150 6.6 3.11 73 .3 - 5.9 8.563 141.3 65 8.5 280 19. VALVE WEIGHt And torQuE VALuES NOMINAL PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) PrESSurE droP (PSI) VS.200 474.0 0. ./Kg †Breakaway Torque (In.3 50° 44 3.1 11.3 141.6 85 2.8 604 41. 40 Ft.9 418 28.1 219.7 21⁄2 65 6 150 6.4 8I N 34.750 12.5 21⁄2 65 8 200 8.1 826 57.0 10000 FLOW RATE IN GALLONS PER MINUTE (GPM) www.5 40° 19 1.625 8.1 1.980 412.0 4 100 4.7 1.2 13.7 0.3 VA LV E 42.6 1.com GL-6.5 CH CH 100 125 150 200 250 300 20.0 20./mm Equivalent Feet of Pipe* C=120 Sch.375 60. Wt.4 2.5 75 9.220 250.8 9.9 9.2 3.160 131.8 1.2 2 50 4 100 4.1 6.2 420 29.067 0.4 2.875 73.6 120 1.3 2 50 2.430 167.3 7.3 30° 7 0.0 20 1.8 35.947 823.3 5.0 5 125 5.5 VA LV E 224 22.1 1./mm O.5 6.210 362.7 1. Contact Anvil for information on torques for dry and non-lubricating fluid service.1 72 8.500 88.678 184.0 80 9.7 - 21⁄2 65 10 250 10. Insulating Thickness In.6 IN 694 794 880 1.1 1.1 100 200 300 400 500 700 1000 2000 3000 4000 5000 12 IN 7000 10 83.Lbs) / N-m VA LV E VA LV E CH 65 80 3 4 5 6 8 3.431 443.3 31.8 215 14.8 1.6 1.7 325 22. 30 Sch.7 2.375 60. (GPM) 5.500 4.365 94.625 168.0 115 10.5 80° 111 7.4 428 67.1 230 15.3 7.4 84 5.2 69.8 1.3 3./mm Operating Pressure * Approx.0 Valve Size In.1 168. In. In.6 320 23.3 O.9 239 16.9 328 22.2 2.4 10.0 3.1 - 5.1 - 3 80 12 300 12.3 21⁄2 65 2.0 2.9 0.4 120.8 100 6.6 452 VA LV E 4I N 2I N 5I N 180 195 200 205 220 6I NC 8. 50 PSIG 100 PSIG 150 PSIG 200 PSIG 300 PSIG Lbs.7 4.480 102.8 10 0.563 141.D.2 182 12.3 276 613 742 CH 12 2./mm 2 50 2.5 † These values are valid for water and lubricating fluid service only.0 307 22.375 60.0 5.8 285 19.6 445 30.3 3.750 323.3 76 5.9 30.750 273.917 329.D.625 10.6 1.0 6.3 9.6 3 80 3.819 332.750 603.1 172 11.4 592 40.9 14 1.7 400 27.7 95 10.3 78 5. Ea.8 1.7 599 0. as a function of temperature ˚F (Fahrenheit) nylon coatinG Coating Condition after 18 months immersion rESIStAncE 68˚F 104˚F 140˚F 176˚F Alcohols benzyl alcohol butanol ethanol (pure) glycerine (pure) glycol methanol (pure) Chlorinated solvents carbon tetrachloride methyl bromide methyl chloride perchloroethylene trichloroethane trichloreothylene Phenols Various Organic Compounds anethole carbon disulphide diacetone alcohol dimethyl formamide ethylene chlorhydrin ethylene oxide furfurol glucose tetraethyl lead tetrahydrofurare Salts. or lindane hudroxy-quinoline (agricultural sprays) soap solution stearin solvent naptha natural gas turpentine vinegar wine Inorganic Acids chromic acid (10%) hydrochlorhic acid (1%) hydrochlorhic acid (10%) nitric acid (all concentrations) phosphoric acid (50%) sulphuric acid (1%) sulphuric acid (10%) sulphur trioxide Other Inorganic products agriculture sprays bleach solutions bromine chlorine fluorine hydrogen hydrogen peroxide (20 volumes) mercury oxygen ozone potassium permanganate (5%) sea water soda water sulphur water Aldehydes & Ketones acetaldehyde acetone benzaldehyde cyclohexanone formaldehyde (technical grade) methylethylketone (MEK) methylethylketone (MIBK) Hydrocarbons acetylene benzene butane cyclohexane decaline HFA (Forane®) hexane methane naphthalene propane styrene rESIStAncE 68˚F 104˚F 140˚F 176˚F rESIStAncE 68˚F 104˚F 140˚F 176˚F Hydrocarbons (cont’d.) tulene xylene Inorganic Bases ammonium hydroxide (concentrated) ammonia (liquid or gas) lime-wash potassium hydroxide (50%) sodium hydroxide (5%) sodium hydroxide (10%) sodium hydroxide (50%) Organic acids & anhydrides acetic acid acetic anhydrie citric acid formic acid lactic acid oleic acid oxalic acid picric acid tartaric acid (saturated solution) uric acid Inorganic Salts alum aluminium sulphate ammonium nitrate barium chloride calcium arsenate (concentrated solutions or slurries) calcium chloride calcium sulphate copper sulphate diammonium phosphate magnesium chloride (50%) potassium ferrocyanide potassium nitrate potassium sulphate sodium carbonate sodium chloride (saturated) sodium silicate sodium sulphide trisodium phosphate Organic bases aniline (pure) diethanolamine (20%) pyridine (pure) urea G G G G G G G G G L L G P G G G L G G G G G G G G G G G G G G* G G G G G G L G L G G*** G*** G G G L G L L P P G P G G G P G G G G G G G G G G G G G L* G G G G L G P G*** P G L L G G P L L P P P L P G G L P G G G G G G G G L G L G G P G L G G L G P G*** P L G G G P G P G L L G G G G G G G G G P G G P G G G L G L P P P G G G G L P G G G G G G G G G G G G G G G G G G G G G G P P G G G G G G*** G*** P P P G P L P P P P P P L L P P L L L P P L** G*** G P G G*** G G G G G G G G G G L G G P L L L L G L G G G G G G G G G P P L L P L L L P G P P P P G L G G P P G G G G L G*** L L L G G G G*** G G G G G G G G*** P P P P P L P P P P P P P P P P P P G P P P G G L P G G G P L P P P L L G L G G G G G G G P P P G G P P G G L L L L G G G L L P G G G G G G G G G G G G G*** G*** G G G*** G*** G G G*** G P P G G P L P L G L L LEGEnd * ** *** G L P = = = = = = Slight Yellowing Yellowing Swelling observed Good Limited Poor G G L G 74 www. esters.anvilintl.com GL-6.) solutions or emulsions of D.T.VALVES And AccESSorIES series 7700 Butterfly Valve Resistance to various chemicals.D.11 . ethers amyl acetate butyl acetate diethyl ether dioctylphosphate dioctylphthalate ethyl acetate fatty acid esters methyl acetate methyl sulfate tributylphosphaate tricresylphosphate Various Products beer cider crude petroleum diesel fuel fruit juices fuel-oil greases ground nut oil high octane gasoline kerosene (paraffin) linseed cake milk mustard normal gasoline oils L G*** G*** G G G*** P G G G L G P G G*** G G P G G G G G G G G G G G G G G GG G G G G G G G G G G G G G G G P L G G G L P P L L G P P Various Products (cont’d. NUT.8 43⁄8 111. STEM SEAL: The interference between the rubber covered disc hub and the smooth.8 bar) to full vacuum.2 23⁄4 70. Rugged enough to take the punishment.2 37⁄16 87. ASTM A 536 2.7 3 21⁄2 65 215⁄16 74. ASTM A 619 SErIES 7600 ButtErFLY VALVE dIMEnSIonS Size In. Every valve is seat tested to 110% of rated pressure./mm 5 E In. STEM: Two-piece design for maximum flow.anvilintl.1 43⁄8 111. General specifications BODY: One-piece ductile iron. A B G REF. fully epoxy coated – light weight for easy handling. at temperatures from 0° to 150° F (-17./mm L In.6° C).9 3 6 150 63⁄4 171.3 27⁄16 62.5 15.4 113⁄16 46./mm D In.4 25⁄8 66. The ductile iron disc is available with a choice of EPDM or Nitrile coverings.3 7 177.8 15.4 1 25. DISC: Streamlined profile for maximum flow and minimal seat wear./mm H In. The Series 7600 Valve is rated 200 PSI (13. 6.1 41⁄4 108.VALVES & AccESSorIES Butterfly Valve Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.0 35⁄8 91.8 87⁄16 214.2 11⁄4 31.9 www.4 1 25.9 5 8. D E C F REF.4 1 25.0 2 50.9 5 8./mm C In.4 1 25. and the elastomer encapsulated disc can be ordered with EPDM or Nitrile materials. Its ductile iron body is epoxy coated to resist atmospheric attack.9 3 3 80 39⁄16 90.4 121⁄4 311. LOWER STEM: AISI 410 4. yet the Series 7600 Valve is light in weight for easy handling and installation.9 5 8.3 33⁄8 86. UPPER STEM: AISI 410 5./mm 2 50 23⁄8 60./mm DIMENSIONS A In.3 87⁄16 214. STEM/DISC ATTACHMENT: A splined interference fit creates a permanent rigid connection between the disc and stem.4 313⁄16 96. HANDLE: Two position on/off handle is standard.5 211⁄16 68.9 5 8.4 35⁄16 84. Top stem is Double D.com GL-7.8 33⁄16 81. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories series 7600 The versatile Series 7600 Grooved-End Butterfly Valve has features that can satisfy a wide range of service requirements and allow it to be used with a diverse range of fluids.12 75 . giving positive indication of disc position at all times./mm G In. O-rings on both upper and lower stems provide a secondary seal.2 313⁄16 96. material specifications 9 7 6 3 5 1 K REF.9 3 4 100 49⁄16 116. TESTING AND CONFORMANCE: Testing to MSS SP-67.3 21⁄4 57.9 8./mm 5 F In. and eliminates the need for pins or bolts in the flow way.3 43⁄8 111.4 ⁄8 ⁄8 ⁄8 ⁄8 ⁄8 ⁄16 ⁄8 ⁄8 ⁄8 ⁄8 6 152. ASTM A 228 8. DISC: EPDM or Nitrile.0 69⁄16 166.0 15./mm B In.9 15. ASTM A 228 7.8° to 65. epoxy coated body provides the primary stem seal.0 15. LATCH SPRING: Electrolytic Coloring. LATCH PLATE: Zinc Plated. 8 ORANGE GRIP L 2 5 4 1.1 35⁄16 84.8 6 152.8 45⁄8 117.4 21⁄16 52.6 51⁄4 133. Grooved ends conform to the requirements of AWWA C606 for steel pipe./mm K In.1 415⁄16 125. HANDLE: Zinc Plated. SELF LOCKING: ASTM A 563 BLACK COATING 9. BODY: Epoxy Coated. STEM O-RING: Nitrile H REF. ASTM A 536 3. /Kg.6 76 www.VALVES And AccESSorIES series 8000Gr Butterfly Valve For use in Grooved-End Piping Systems 14" to 24" features • Up to 200 psig (13. oil-free air and many chemical services. Valve Size ANSI In.1 452 205. Valve with Gear Operator Lbs. 29.11 . vegetable oils and mineral oils.6 354 160.2 24 600 24 609.5 16 400 16 406.8 1.6 378 171.6 1. NOT FOR USE IN HOT WATER SERVICES.0 18 450 18 457.8 bar) WOG (non-shock) Special order .7 548 248.0 704 319.3 bar) WOG (non-shock) 200 PSIG (13.3 728 330.com GL-6.097 497.4 428 194.WEIGHt O. Grade T (Nitrile) -20°F to 180°F (Service Temperature Range) (-29°C to 82°C) Recommended for petroleum products./Kg.5” (750 mm) Hg Vacuum Service TEMPERATURE RATINGS: Grade E (EPDM): -40°F to 230°F (-40°C to 110°C) (Service Temperature Range) Recommended for water service.5” (750 mm) Hg • End-of-line service capabilities butterfly valve performance data PRESSURE RATINGS: 150 PSIG (10.2 524 237.D.6 20 500 20 508.027 465. air with oil vapors./DN(mm) FIGurE 8000Gr .available upon request. alkaline. NOT FOR USE IN PETROLEUM SERVICES. 14 350 14 355.8 bar) WOG (non-shock) • Outstanding flow characteristics • Low torque operation • Superior flow control • Streamline profile disc • Suitable for HVAC applications • Vacuum service to 29./mm Weight Valve Only Lbs. dilute acids. In.anvilintl. /mm N In.ASTM A 276 Type 316 BOTTOM SHAFT: Stainless Steel .24" G Body Style G . In.Square Nut (with Gear Operator) 7 .B EXTENSION BODY: Pipe . HOLE DIA.ASTM A 276 Type 316 RETAINING SCREW: Steel THRUST WASHER: Acetal PLUG: Cast Iron . SIZE OF KEY G F B P A M C DIA./mm 350 400 450 500 600 14 14./mm F In.Gear Operator 3 .000 24.ASTM A 126 CL.Chain Wheel (with Gear) www./DN(mm) O./mm R In. w/ RTFE Bearing 2 .Nitrile 2 . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories series 8000Gr material specifications BODY: Cast Iron ./mm G In. BOLTHOLE K J DIA./mm C In.None 2 Operator 6 Stem 6 .ASTM A 126 CL./mm E In.416 S.ASTM A 582 Type 416 Stainless Steel .Cast Iron 8 Series 8 . L SErIES 8000Gr ButtErFLY VALVES .Nickel Plate Ductile Iron 7 .Bronze (Al-Brz./mm M In.8000 2 Seat Material 1 ./mm 3 J In.000 20.B UPPER BEARING: Teflon (Reinforced) LOWER BEARING: Teflon (Reinforced) DIA.EPDM 8 Disc Material 0 .ASTM A 536 Grade 65-45-12 DRIVE SHAFT: Stainless Steel .) 0 .ASTM A 582 Type 416 Stainless Steel .000 356 406 457 508 610 261⁄4 667 1 131⁄4 337 3 533 21 1 21⁄4 57 1 11⁄2 38 1 51 51 2 2 ⁄8 x 3⁄8 87 87 87 87 152 152 171 171 241 6 6 13 1 ⁄2 ⁄2 ⁄2 ⁄2 131⁄16 332 5 103⁄4 273 1 127 127 127 127 165 5 5 1715⁄16 456 7 254 254 254 254 10 10 10 10 16 18 20 24 16./mm A In.ASTM A 53 Steel Flange .VALVES & AccESSorIES Butterfly Valve Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.Electric 5 .com GL-6.S./mm D In./mm K In.000 29 ⁄2 749 832 864 1.ASTM B 148 C95400 Ductile Iron .Spring Return Pneumatic 6 . GRADE T (Nitrile) DISC: Stainless Steel .5 Forged Steel LINER: Grade E (EPDM).ANSI B16.ASTM A 351 Aluminum Bronze .dIMEnSIonS Valve Size ANSI In.D.000 14 ⁄4 375 400 413 1 23 ⁄2 597 635 2 ⁄4 57 76 76 76 1 ⁄2 38 44 44 1 3 ⁄8 x ⁄8 3 13 1 14 ⁄16 364 391 416 1 12 ⁄2 318 356 381 19 ⁄16 494 519 532 3 323⁄4 34 3 153⁄4 161⁄4 19 ⁄8 486 25 3 13⁄4 13⁄4 2 ⁄4 57 23⁄8 60 66 1 3 ⁄8 x 3⁄8 ⁄8 x 3⁄8 ⁄2 x ⁄2 1 63⁄4 63⁄4 9 ⁄2 1 13 1 153⁄8 163⁄8 18 ⁄4 464 14 15 3 5 5 1 207⁄16 2015⁄16 24 ⁄8 619 271⁄2 699 813 3 25⁄8 3 ⁄4 83 3 13 13 39 ⁄8 32 3 1 116 21 ⁄16 16 ⁄4 425 6 ⁄2 101⁄4 260 SErIES 8000Gr ButtErFLY VALVES (ordErInG InForMAtIon) Sample Part Number 18" GC-8282-6 ––> 18" Valve Size 14" .Pneumatic 4 .316 S./mm P In. N R D POSITION INDICATOR GEAR OPERATOR (Shown 90° out of Position) E DIA. w/ RTFE Bearing 7 .000 18.S.anvilintl./mm B In.316 S.11 77 .S 8 .Grooved End CBody Material C ./mm 1 L In. 6 1.8 23.585.700 668. notE: These values are based on testing performed in the Gruvlok Research & Development Center.931 1.4 Fluid Dynamic Torque is the force exerted when a fluid passes over the surface of the butterfly valve disc.400 510.500 734 8.469 Breakaway Torque (In.6 6.000 1. Breakaway torque is the total of the torques resulting from bearing friction and disc/seat interference friction at a given pressure differential.940 873.6 60° 3. This value is normally the highest required torque to operate a valve.00) Valve Size In.800 542 5. For applications above these limits.12 .7 9.800 330.000 452 16 4.000 2.792 2.500 621 6.9 3.000 1.200 427. and is used to size the actuator.800 262.9 7.800 542 18 5. NOTE: For Teflon seated valves.500 241. Gr.9 4.8 90° 10.) / N-m 50 3.400 610 20 10.) See “Area of Pipe” chart V = 0.300 158. cV VALuES (WAtEr @ 70°F SP.000 68.9 4.500 861. the friction of the disc and seat due to interference for sealing.5 1.8 31.000 1.600 730.200 588 6. .9 2.0 5.500 103.anvilintl.500 723.9 18.8 13.3 70° 6.600 455.2 7.29 16 400 1. Contact factory for information on torques for dry and non-lubricating fluid service.000 feet/minute for gases to minimize the effects of turbulence on the valve.8 17. fluid dynamic torque is a maximum at an approximate 75° disc opening.650 113.553 1.5 80° 9.600 317.000 1. These values are valid for water and lubricating fluid service only.1 10.8 1. These values include a safety factor and are valid for water and lubricating fluids only at 70° F (21° C).227 1. consult engineering.000 1. bearing friction.794 24 600 2.900 199.450 168.850 127. the effects of dynamic torque can be ignored when the velocity is less than 15 feet/second for liquids and 15.com GL-7.400 96. ActuAtor SIZInG For GEnErAL SErVIcE APPLIcAtIon SErIES 8000Gr BrEAKAWAY torQuE Line Pressure (PSI)/Bar Valve Size (In.034 150 10.594 78 www.400 165.100 75.500 960 13.9 14 350 16 400 850 58./mm Area Sq.200 289.140 The formula for determining the velocity of gases: Qf A Vg = Velocity of gas (feet/minute) Qf = Flow of gas @ flowing condition* (cubic feet/minute) A = Area of upstream pipe (sq.241.8 18 450 1.) See “Area of Pipe” Chart Vg = * Flowing condition means at temperature and pressure of gas stream in the valve 18 450 1.) 14 4. Listed below are recommended sizing torques. ft.525 21.1 10.8 3.9 1.443 20 500 1.1 23. and fluid dynamic torque. The magnitude of this force is dependent on valve size.8 13. ft/Sq.1 20 500 1.500 1.050 210.6 2./mm Disc Position (Degrees Open) 25° 650 44.500 2.500 723.000 1.223.500 1.4 50° 2.130 24 13.400 96.8 24 600 2. cm 14 350 0.4 100 6.000 344. disc opening and flow through the valve.585.VALVES And AccESSorIES series 8000Gr Butterfly Valve Torque is the rotary effort required to operate a value. contact your Anvil Sales Office.Lbs.172. = 1.2 12.3 4. Generally. This turning force in a butterfly valve is determined by three factors.412 18.850 954.8 30° 825 56.5 4.000 137.750 1.9 40° 1.000 2.700 668. The formula for determining the velocity for liquids is: Q A V = Velocity of liquid (feet/second) Q = Flow (gallons/minute) A = Area of upstream pipe (sq.137.5 2.200 701 12.429 Since torques are greatly increased for dry and non-lubricating fluids and temperature variations.9 17.3 5. ft. contact your Anvil Sales Office for accurate values in these applications.500 517.0022 ArEA oF PIPE Pipe Size (Sch 40) In.500 930. Typically. 15 11⁄4 .95 49.com GL-10.8 97.3 65 . Size Range: 1⁄4" .1 21⁄2 .25 20 ./mm locK DeVice Size In./mm B In.6 67.6 67.10 .⁄2 3 3 3.5 ⁄4 .4 60. and full port soldered end (Figure 1715).5 bar). commercial and industrial applications.9 151. dependable design./mm 1 20 .1".0 2.10 104.8 121./mm sTeM eXTeNsioN (Brass) Size In.10 .0 materIal specIFIcatIoNs BODY: Brass CW 617N UNI EN 12165 RETAINER: Brass CW 617N UNI EN 12165 BALL: Brass CW 617N UNI EN 12165 STEM: Brass CW 614N UNI EN 12164 SEAT RING: PTFE PACKING: PTFE PACKING NUT: Steel 6S PACKING GLAND: Brass CW 614N UNI EN 12164 FRICTION WASHER: PTFE STEM O-RING: NBR HANDLE: Steel. hard chrome plated ball.1 ⁄2 1 5. visit our website at www.1 1.4 bar) WOG 150 psi (10. Pressure Rating from full vacuum to: 600 psi (41.0 2 50 6.4".15 ⁄4 ./mm A In.40 1.0 1 ⁄4 . The two piece 1715 and 171N full port design are available in sizes 1⁄4" . adjustable packing gland.2" STEM EXTENSION: 1⁄4" . 1715 The Anvil Figure 171N and 1715 Brass Ball Valves have a rugged.4" “T” HANDLE: 1⁄4" .0 20 . Anvil’s Brass Ball Valves are available in full port threaded end (Figure 171N).6 67.0 ⁄4 .91 48.anvilintl.3⁄8 . Please contact your Anvil Representative for assistance.40 5.0 2.0 2.com or contact an Anvil® Sales Representative. Aluminum to 4" HANDLE COVER: Yellow PVC Coated to 2".5 20 .8 121.5 64 1.0 ⁄4 .5 ⁄4 .1 4.5 11⁄4 .0 203.25 8 . www.1 2. MSS-SP-25 and Federal Specification WW-V-35B Type II. Yellow Enamel to 4" HANDLE NUT: Steel.10 .5 2./DN(mm) 1 ⁄4 .1 2.40 21⁄2 .⁄8 . Every valve is individually tested in an open and closed position at 80 psi (5.12 79 .57 40. Features of these valves include triple stem seal. meeting rigid specification for world wide use./mm 1 B In.4" LOCK DEVICE: 1⁄4" .15 ⁄4 .1 1 4.4 162.5 A In.80 8.9 151.11⁄2 32 .0 50 1.1 2 50 6.⁄2 3 3 2.0 32 .3 65 . blowout proof stem.1⁄2 3 1.90 99.ValVes & accessories International Brass Ball Valves Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. a bubble tight shut off and a floating ball for an economical solution for residential.28 32. 171N & FIG. Zinc Plated AVAILABLE OPTIONS* LEVER HANDLE: 1⁄4" . A “T” handled version of the 171N is also available as Figure 171N-T in sizes 3⁄8" .anvilintl.2 259.5 A In.15 8 .08 27.25 2 50 1.8 97.0 4 100 10.3 bar) WSP “T” HaNDle Size In.80 3. Class A Style 3.1" * Not all options available for all sizes./DN(mm) 1 8 .4 162. Zinc Plated to 2".⁄8 .11⁄2 32 . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories FIG.0 ⁄4 .10 .0 4 100 4./DN(mm) 1 A In.3⁄8 ./DN(mm) 1 MeMorY sToP Size In.30 33.6 67. All valves conform to MSS-SP-110.2 2.4" Figure 171N For Listings/Approval Details and Limitations.1⁄2 3 3.25 8 .4" MEMORY STOP: 1⁄4" .6 67. VALVES And AccESSorIES fiG. 171n & fiG. 1715 International Brass Ball Valves C Valve Code Size In./mm dIMEnSIonS Port Dia. In./mm 3 A In./mm C In./mm D In./mm Cv 6 7 19 35 50 104 268 309 629 1018 1622 19 35 50 104 268 309 629 1018 1622 Approx. Wt. Ea. Lbs./Kg OPOR T D 1 ⁄4 ⁄8 ⁄2 ⁄4 ⁄8 ⁄8 2 51 37⁄8 98 13⁄4 45 0.3 0.1 8 3 10 3 2 51 37⁄8 98 13⁄4 45 0.3 0.1 10 1 10 9 ⁄16 ⁄4 ⁄16 27⁄16 62 37⁄8 98 17⁄8 48 0.4 0.2 15 3 14 3 211⁄16 68 413⁄16 122 21⁄4 57 0.7 0.3 20 19 15 A 171N FULL PORT THREADED END 1 25 31⁄16 78 413⁄16 122 27⁄16 62 1.0 0.5 24 11⁄4 32 11⁄4 32 37⁄16 87 6 152 31⁄16 78 2.0 0.9 11⁄2 40 19⁄16 40 37⁄8 98 6 152 35⁄16 84 3.1 1.4 pressure vs. temperature BAR PSIG 700 45 600 40 2 50 115⁄16 49 45⁄16 110 63⁄8 162 313⁄16 97 4.2 1.9 21⁄2 65 29⁄16 65 59⁄16 141 81⁄16 205 5 127 8.0 3.7 3 80 31⁄8 79 67⁄16 164 85⁄16 205 57⁄16 138 12.0 5.9 PRESSURE 500 30 400 300 200 10 100 0 0 -20 0 -28 0 4 100 1 315⁄16 100 9 75⁄8 194 101⁄4 260 65⁄16 160 22.0 10.0 ⁄2 ⁄4 ⁄16 ⁄4 21⁄2 64 37⁄8 98 17⁄8 48 0.5 0.2 15 3 14 3 20 3 76 413⁄16 122 25⁄16 59 0.7 0.3 20 19 1 25 1 25 39⁄16 91 413⁄16 122 21⁄2 64 1.1 0.5 5 100 50 150 200 100 250 300 150 350 400 200 450 500° F 250 °C 1715 FULL PORT SOLDERED END 11⁄4 32 11⁄4 32 41⁄16 103 6 152 31⁄8 79 2.0 0.9 11⁄2 40 19⁄16 40 49⁄16 116 6 152 33⁄8 86 2.7 1.2 TEMPERATURE NOTES 1. Dimensions of solder joint ends conform to ANSI B16.22. Solder end valves are designed to be used with solders not exceeding a melting point of 470°F/250°C. Higher temperatures may damage the seal material. 2. For solder joint valves, the pressure/ temperature rating is dependent on the solder material used. Please refer to the limitations listed in ANSI B16.18. 3. Rate of Flow Calculations for liquids: To determine the flow rate of a liquid passing through a valve, use the following formula: 2 50 115⁄16 49 57⁄16 138 67⁄16 164 311⁄16 94 3.9 1.8 21⁄2 65 29⁄16 65 67⁄8 175 81⁄16 205 5 127 9.4 4.3 3 80 31⁄8 79 83⁄16 208 81⁄16 205 57⁄16 138 14.5 6.6 4 100 315⁄16 100 105⁄16 262 101⁄4 260 65⁄16 160 24.7 11.2 Where: QL = flow of liquid in gallons per minute (GPM) CV = flow coefficient ∆P = pressure drop (PSI) SL = specific gravity of liquid 80 www.anvilintl.com GL-7.12 VALVES & AccESSorIES Ball-valves Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories series 7500 The Series 7500 grooved-end ball valve line consists of a 2" to 6" standard port, two piece design, and is available in configurations to address a broad spectrum of application requirements. The Series 7500 has generous factors of safety for pressure retention and stem torsional strength. In addition, it has a blow-out proof stem design, low operating torque, and high Cv. The Series 7500 is compliant with NACE MR01-75 when stainless steel trim is specified. Grooved ends conform to the requirements of AWWA C606 for steel pipe. For special configurations, contact your Anvil representative. For stainless steel, see the stainless steel section. PRESSURE-RATING: 740 psig CWP (51 bar) in ASTM A 395 Ductile Iron fiGure 7500 material specifications DUCTILE IRON/CARBON STEEL BODY: Ductile Iron ASTM A 395 ENDPLATE: Ductile Iron ASTM A 395 BALL: Carbon Steel Chrome Plated STEM: Carbon Steel Chrome Plated THRUST WASHER: RTFE STEM SEAL: Flouroelastomer RETAINING RING: Carbon Steel HANDLE: Carbon Steel Zinc Plated HANDLE NUT: Carbon Steel Zinc Plated SEAT: RTFE BODY SEAL: Flouroelastomer LOCK PLATE*: 300 Series Stainless Steel * Optional DUCTILE IRON/STAINLESS STEEL BODY: Ductile Iron ASTM A 395 ENDPLATE: Ductile Iron ASTM A 395 BALL: Stainless Steel ASTM A 351 Grade CF8M STEM: 316 Stainless Steel THRUST WASHER: RTFE STEM SEAL: Flouroelastomer RETAINING RING: Carbon Steel HANDLE: Carbon Steel Zinc Plated HANDLE NUT: 300 Series Stainless Steel SEAT: RTFE BODY SEAL: Flouroelastomer LOCK PLATE*: 300 Series Stainless Steel * Optional www.anvilintl.com GL-6.11 81 VALVES And AccESSorIES series 7500 Ball-valves B D A G C B E H F C J L K D B CLOSED OPEN A 6" - 7500 Ball Valve with Gear Actuator F E Valve Pipe O.D. 7500 BALL VALVE Size ANSI In./DN(mm) O.D. In./mm Dimensions A In./mm B In./mm C In./mm D In./mm E In./mm F In./mm Cv 165 310 815 1500 Approx. Wt. Ea. Lbs./Kg 2 50 2.375 60.3 51⁄2 140 23⁄4 70 81⁄4 209 313⁄16 81 115⁄16 49 41⁄8 105 8 3.6 3 80 3.500 88.9 63⁄4 171 33⁄8 85 10 254 413⁄16 122 27⁄8 74 413⁄16 121 18 8.2 4 100 4.500 114.3 81⁄4 210 41⁄8 105 16 406 65⁄16 176 313⁄16 97 6 152 38 17.2 6* 150 * Bare Stem 6.625 168.3 101⁄8 257 51⁄16 128 28 711 87⁄16 215 511⁄16 144 75⁄8 194 106 48.1 7500 BALL VALVE WItH GEAr ActuAtor Size ANSI In./DN(mm) O.D. In./mm Dimensions A In./mm B In./mm C In./mm D In./mm E In./mm F In./mm G In./mm H In./mm J In./mm K In./mm L In./mm Approx. Wt. Ea. Lbs./Kg 6 150 6.625 168.3 65⁄8 168.7 41⁄4 107.4 87⁄16 214.6 51⁄2 140.5 101⁄4 260.4 51⁄16 128.0 81⁄8 206.4 12 304.8 131⁄2 342.9 113⁄16 45.2 1 25.4 9.6 4.4 SErIES 7500 BALL VALVES (ordErInG InForMAtIon) Sample Part Number 4" GI-7512-1 ––> 4" Size 2" - 6" G Configuration G - 2 Way Grooved End IBody/End Material I - Ductile Iron ASTM A395 75 Series 75 - 7500 1 Ball and Stem Material 1 - Chrome Plated Carbon Steel 2 - 316 Stainless Steel 2Seat Material 2 - RTFE / Flouroelastomer Special Requirements X - Write on Order 1 Operator 1 - 2 Position Handle 2 - 2 Position Locking Handle 3 - Bare Stem 4 - Gear Actuator (6" Only) 6" is available bare stem or with gear actuator. 82 www.anvilintl.com GL-6.11 VALVES & AccESSorIES Grooved-End Silent Check Valve Available in Sizes 2" thru 10" Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 400G The 400G is a center guided, spring loaded, silent check valve. Designed and engineered for silent operation with low head loss, the valve disc will close prior to the reversal of flow, thereby preventing or minimizing water hammer and damaging shock. • The 400G can be used in any HVAC, industrial or commercial grooved piping systems. • The valve is designed for liquid service with any pipe orientation, flow up or down. • Bronze metal seats are standard, with Stainless Steel or resilient seats available as an option. • Flow coefficients for this valve are some of the lowest in the industry and are listed for each size on the drawing. NOTE: Valve is designed for liquid service only. Install 3 to 4 pipe diameters downstream from pump discharge or elbows to avoid flow turbulence. FIGurE 400G GrooVEd-End SILEnt cHEcK VALVE Valve Size In./mm O.D. In./mm Model Number A In./mm B In./mm Cv Flow * 66 1,676 Approx. Wt. Each Lbs./Kg 2 50 2.375 60.3 402G 4025G 403G 404G 405G 406G 408G 410G 6 152 6 152 12 5.4 21⁄2 65 2.875 73.0 61⁄4 159 7 178 88 2,235 15 6.8 3 80 3.500 88.9 67⁄16 164 71⁄2 191 130 3,302 20 9.1 4 100 4.500 114.3 81⁄8 206 9 229 228 5,791 36 16.3 5 125 5.563 141.3 111⁄4 286 10 254 350 8,890 50 22.7 MAX. non-SHocK WorKInG PSI 125# AnSI B16.1 FLAnGE rAtInG Size 150˚F 2" - 10" 65°C 6 150 6.625 168.3 121⁄4 311 11 279 520 13,208 68 30.8 8 200 8.625 219.1 133⁄4 349 131⁄2 343 900 22,860 140 63.5 Temperature 200˚F 90°C 10 10.750 16 16 1,450 198 200 PSI 13.8 bar 190 PSI 13.1 bar 250 273.1 406 406 36,830 89.8 * Flow coefficient is the number of U.S. gallons/minute of 60˚ F (16˚ C) water that will flow through a valve with 1 psi (0.069 bar) of pressure drop across the valve. material specifications STANDARD MATERIALS: Cast Iron body ASTM A 48, Class 35 Bronze Disc and Seat ASTM B 584 Alloy 838 Ductile Iron Grooved-Ends ASTM A 395 OPTIONAL TRIM MATERIALS: Bronze with Nitrile seats Stainless Steel seats Stainless with Nitrile seats 1. BODY: Cast Iron ASTM A 48, Class 35 2. SEAT: Bronze ASTM B 584, Copper Alloy 838 3. PLUG: Bronze ASTM B 584, Copper Alloy 838 4. SPRING: Stainless Steel T304, ASTM A 313 5. BUSHING: Bronze ASTM B 584, Copper Alloy 836 6. SCREWS: Stainless Steel T304, ASTM A 276 7. GROOVED-END: Ductile Iron ASTM A 395 8. GASKET: Non Asbestos For gasket grade recommendations see the Technical Data section 9. BOLTS: Carbon Steel Other materials and resilient seats are available... contact your Anvil representative. Cv FLOW 1 2 3 4 B 8 6 A 5 7 9 8 www.anvilintl.com GL-6.11 83 VALVES And AccESSorIES series 7800 Check Valves For use in Grooved-End Piping Systems The Gruvlok Series 7800 Check Valve is a compact, cost effective valve offering low pressure-drop, non-slam performance. The Series 7800 Check Valve assembly is lighter and faster to install, and costs less than flanged and wafer valve assemblies. In the fully open position the Series 7800 swing clapper is held tightly against the valve body, out of the flow stream, to provide maximum flow area and prevention of clapper flutter. The clapper design produces quick, non-slam closure before flow reversal can occur, while meeting FM requirements for an anti-water hammer valve rating. Each valve is hydrostatically tested for leak tightness to 500 PSI. The clapper-seat design permits leak free sealing of back pressures in service conditions ranging from 300 PSI (20.7 bar) to as low as 1 PSI (0.07 bar) (head pressure: 28"). performance: Pressure Rating: Commercial Applications - Sizes 2" thru 12" inclusive, 300 psi (20.7 bar) maximum working pressure. For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. material specifications BODY: Ductile iron conforming to ASTM A 536, Grade 65-45-12 COATING: Rust inhibiting paint on exterior and interior – color: black enamel CLAPPER: 2”- 5” Type 304 or 302 stainless steel to ASTM A 167 6"-12" Ductile iron conforming to ASTM A 536, Grade 65-45-12 CLAPPER FACING: Grade E EPDM: -40° to 230°F (-40° to 110°C) Service Temperature Range Recommended for water service, dilute acids, alkaline, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM SERVICES. Body Spring Bushings (2) Hinge Pin Clapper Assembly Grade T Nitrile: -20° to 180°F (-29° to 80°C) Service Temperature Range Recommended for petroleum products, air with oil vapors, vegetable oils and mineral oils. Hinge Pin Plug (2) NOT FOR USE IN HOT WATER SERVICES. SEAT RING: Type 304 stainless steel to ASTM A 123, ASTM A 213, ASTM A 312 or ASTM A 269 SPRING: Type 302 stainless steel to ASTM A 313 HINGE PIN: Type 304 or 302 stainless steel to ASTM A 580 HINGE PIN BUSHINGS: Sintered bronze to ASTM B 438 HINGE PIN PLUGS & DRAIN PLUGS: Cast iron to ASTM A 126 Class A Drain Connections Seat Ring 84 www.anvilintl.com GL-7.12 based on the Hazen and Williams formula. The friction losses have been calculated on the basis of flow rates typically used with each size valve.8 30 9. 40 Ft.0 0.0 1.0 — — 8 2.5 25 7.750 323.5 1.0 7.0 6.6 0.0 0.0 — — 19 5./m Sch./m Sch.0 7. Sound piping practices dictate a minimum of five (5) times the pipe diameter for general use.1 10 250 10. reducers or other similar devices.4 20 6.0 8.2 — — 12 3.875 73.0 10" Val ve 12" Val ve 5" V alv 6" V e alve 8" V alve Va lv Va lve lve e 3.9 37 11.5 FLOW RATE IN GALLONS PER MINUTE (GPM) FLoW dAtA: The approximate friction losses.0 5. In a horizontal installation. expanders. This valve may be installed vertically or horizontally. In.500 114.4 28 8.3 14 4.anvilintl.1 28 8.3 — — 11 3.7 43 13.4 14 4. Valve Size In.5 26 7. 10 Ft. oF PIPE) O.2 — — 13 4.0 — — 17 5.VALVES & AccESSorIES Check Valves Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 30 Ft.12 85 .3 IMPORTANT NOTE: Check valve life may be shortened and system damage may occur if check valves are installed too close to a source of unstable flow.8 0.2 4 100 4. Check valves must be installed at a reasonable distance away from pumps.625 219.4 39 11.9 44 13.0 23 7.9 0. Distances less than 3 diameters are not recommended.9 31 9. expressed in equivalent length of pipe is given below.0 6.7 32 9.D.4 12 300 12.1 — — 15 4.1 50 15.2 36 11.1 — — 26 7.0 4.1 35 10. www.3 40 12.3 17 5. 10 Ft. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories series 7800 For use in Grooved-End Piping Systems Friction Loss Series 7800 Check Valve (Water at 65˚F) NOMINAL PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) NOMINAL PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) 9.0 34 10.0 20 6.3 — — 11 3.5 100 200 300 400 500 700 1000 2000 3000 4000 5000 7000 10000 1.6 0.3 10 3. 30 Ft.9 8 200 8.375 60.8 0. the hinge pin is to be located on top.4 21⁄2 65 2./m 2 50 2.9 0.3 — — 10 3.0 5.625 168.5 21 4" V a /2" 3.0 8./mm FLoW dAtA .0 Va lve 2.563 141.com GL-7.0 9.0 4. Not for use in copper systems.2 45 13.8 33 10.0 1.0 — — 18 5./m Sch.9 17 5./mm C=100 Sch.0 14 4.6 3 80 3. elbows.3 23 7.5 5 125 5./m C=120 Sch.750 273./m Sch.FrIctIon LoSS (Ft.0 3" 2" 2.7 23 7.6 6 150 6.500 88.7 0.7 0. Distances between three (3) and five (5) diameters are allowable provided the flow velocity is less than 8 feet per second. 40 Ft.1 — — 15 4.6 24 7. /DN(mm) O.875 73.Nitrile (Std) 1 Body Finish 1 .0 71⁄4 184 27⁄16 61 19⁄16 39 13⁄4 44 313⁄16 96 35⁄8 92 41⁄2 114 10./mm Approx.3 123⁄4 324 41⁄4 108 35⁄16 84 31⁄8 79 61⁄4 159 63⁄4 171 81⁄2 216 33.2 4 100 4.1 143⁄8 365 51⁄16 128 315⁄16 100 4 102 515⁄16 150 8 203 101⁄4 260 59./mm F In.563 141.0 26.3 93⁄4 248 31⁄2 89 23⁄4 70 27⁄16 61 513⁄16 147 45⁄8 117 63⁄4 171 19.EPDM (Std) 2 .9 73⁄4 197 25⁄8 67 2 51 13⁄16 46 41⁄16 103 311⁄16 93 415⁄16 125 11.625 168.375 60.6 6 150 6.D.5 6.5 3.500 88. Ea./mm D In.0 83.5 5.500 114. material specifications FIGurE 7800 cHEcK VALVE G Nominal Size In.0 59./mm C In.8 3 80 3./Kg. Wt.2 8 200 8.12 .4 A Hinge Pin Plug Lifting Eyebolt (10" and 12" Valves Only) B D E 1 21⁄2 65 2.1 18 457 65⁄16 160 415⁄16 125 49⁄16 115 67⁄8 175 93⁄16 233 1211⁄16 322 130.3 63⁄4 171 23⁄8 60 17⁄16 36 13⁄4 44 41⁄2 114 33⁄16 81 43⁄8 111 7.0 86 www./mm Nominal Dimensions A In. Lbs.750 323. In.0 12 300 12.8 /2" NPT 10 250 10./mm B In.Painted (Std) 2 .625 219.9 21 533 75⁄16 185 6 152 51⁄16 128 71⁄4 184 103⁄8 264 143⁄4 375 183.Other* X Special Configuration * Contact an Anvil representative for more information. 2 50 2.12" 78 Series 78 ./mm E In./mm G In.0 8.com GL-7.7800 1 Clapper Facing Material 1 .1 F C 1 /2" NPT 5 125 5.5 15.750 273.anvilintl.VALVES And AccESSorIES series 7800 Check Valves For use in Grooved-End Piping Systems SErIES 7800 cHEcK VALVES (ordErInG InForMAtIon) Sample Part Number 4" 7811––> 4" Size 2" .5 4.3 81⁄8 206 31⁄8 79 21⁄4 57 21⁄2 64 51⁄16 128 41⁄4 108 6 152 13. /mm F In.3 171⁄2 445 131⁄16 331 35⁄8 92 11⁄4 32 415⁄16 125 10 254 11 279 90 40.1 30 762 261⁄2 673 69⁄16 166 21⁄4 57 915⁄32 240 16 406 171⁄2 445 460 208.3 14 356 109⁄16 268 3 76 11⁄4 32 37⁄16 87 91⁄4 235 10 254 41 18. Grade 65-45-12 The Series GBV is a multi-turn./mm Approx./DN(mm) O. Working Temperature 300°F (150°C) Straight Shown features & benefits • Pressure differential ports on both sides of the valve • Convertible design.0 8 200 8. Max./mm B Open In./mm G Flange 250# In.anvilintl.9 381⁄16 966 287⁄16 722 75⁄8 194 21⁄4 57 125⁄8 321 19 483 201⁄2 521 870 394.VALVES & AccESSorIES Balancing Valves Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs./mm C In.6 F 100 5 125 5. Y-style globe valve designed for accurate determination and control of fluid flow to circuits requiring precise balancing.0 12 305 9 ⁄8 5 2 ⁄4 3 1 25 2 ⁄16 9 7 178 7 ⁄2 1 25 11.3 2011⁄16 525 133⁄4 349 47⁄16 112 2 51 57⁄8 149 11 279 121⁄2 318 130 59./mm Flange Diameter G Flange 125# In.6 NOTE: Grooved-Ends are for connection of components with dimensions conforming to Gruvlok® standard grooved specifications for IPS pipe.750 323.625 219.3 65 244 70 65 191 3 80 3.563 141. www.875 73.6 10 250 10.500 88. Grade 65-45-12 STEM & DISC: Brass Alloy B16 ELASTOMERS: EPDM HANDWHEEL: Reinforced Nylon. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gbv-G. Gbv-a & Gbv-f Ductile Iron ASTM A536. ABS Gbv-G – Balancing Valve 2 1⁄2" to 12" Ductile Iron.D./mm A In.750 273. Each Lbs. BONNET: Ductile Iron ASTM A536. GrooVEd-End or FLAnGEd-End StrAIGHt Nominal Size In./Kg B C E A G 2 ⁄2 1 2./mm E In.1 283⁄16 716 245⁄8 625 511⁄16 144 21⁄4 57 77⁄8 200 131⁄2 343 15 381 310 140.8 6 150 6.500 114.12 87 . Grooved-End or Flanged-End Straight FIGurE GBV-G GrooVEd-End StrAIGHt BALAncInG VALVES ductILE Iron. straight to 90° angle by removing and replacing four set screws • Positive shutoff for equipment servicing • Multi-turn adjustment • Ergodynamically designed handwheel • Micrometer type adjustment scale • Tamper-proof hidden memory stop material specifications BODY.625 168.7 12 300 12. Wt. In.9 12 305 101⁄2 267 27⁄16 61 1 25 3 76 71⁄2 191 81⁄4 210 28 12.7 bar (PN20) Max.7 4 4.com GL-7. Working Pressure 300 PSI / 20. GrooVEd-End or FLAnGEd-End AnGLE O. Grooved-End and Cast Bronze.500 114.6 NOTE: Grooved-Ends are for connection of components with dimensions conforming to Gruvlok® standard grooved specifications for IPS pipe.750 323. 88 www.6 C 5 125 5. Gbv-a & Gbv-f Balancing Valves Ductile Iron./mm G Flange 250# In.9 83⁄16 213 101⁄2 267 27⁄16 61 37⁄8 98 1 25 3 76 71⁄2 191 81⁄4 210 28 12.com GL-7.12 ./mm C In.3 95⁄8 244 109⁄16 268 3 76 43⁄8 111 11⁄4 32 37⁄16 87 91⁄4 235 10 254 41 18.7 12 300 12./mm Approx.0 8 200 8./mm Flange Diameter G Flange 125# In./DN(mm) 21⁄2 65 2.8 6 150 6.1 205⁄16 515 261⁄2 673 69⁄16 166 93⁄4 248 21⁄4 57 915⁄32 240 16 406 171⁄2 445 460 208./mm F In. Grooved-End or Flanged-End Angle Nominal Size FIGurE GBV-A GrooVEd-End AnGLE BALAncInG VALVES ductILE Iron.500 88.1 1815⁄16 481 245⁄8 625 511⁄16 144 93⁄16 233 21⁄4 57 77⁄8 200 131⁄2 343 15 381 310 140.625 219./mm B Open In./mm D In.anvilintl. In. Wt.750 273.7 D A F 80 4 100 4.0 73⁄8 187 95⁄8 244 23⁄4 70 45⁄8 117 1 25 29⁄16 65 7 178 71⁄2 191 25 11.3 12 305 131⁄16 331 35⁄8 92 51⁄2 140 11⁄4 32 415⁄16 125 10 254 11 279 90 40. Each Lbs.563 141.625 168.VALVES And AccESSorIES Gbv-G.6 10 250 10.anvilintl. See www.3 3 3./Kg B G E In.3 141⁄8 359 133⁄4 349 47⁄16 112 65⁄8 168 2 51 57⁄8 149 11 279 121⁄2 318 130 59./mm E In. Solder & Threaded GBV Gbv-a – Balancing Valve 21⁄2" to 12" Ductile Iron./mm A In.D.875 73.com for installation instructions and flow data.9 241⁄16 611 287⁄16 722 75⁄8 194 14 356 21⁄4 57 125⁄8 321 19 483 201⁄2 521 870 394. 2" Model GBV050VS GBV075VS GBV100VS GBV125VS GBV150VS GBV200VS Nominal Size In./mm Approx.1 1.3 3. A small adjustment in the ball opening can mean a huge change in flow.2" CAST BRONzE. Lbs./mm C In.1 0.1 0.5 15 3 ⁄2" ⁄4" 80 3 1 117 125 135 143 150 45⁄8 7 23⁄4 70 3 1. providing 16 times finer adjustment than a ball valve.2" C In.5 20 25 32 40 50 3 ⁄16 93 108 4 ⁄16 118 126 137 142 162 2 ⁄4 70 70 70 70 70 1. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gbv-s & Gbv-t The Series GBV is a multi-turn.8 1.anvilintl.2 1.0 1" 11⁄4" 11⁄2" 2" 41⁄4 415⁄16 53⁄8 55⁄8 23⁄4 23⁄4 23⁄4 23⁄4 1" 11⁄4" 11⁄2" 2" 313⁄16 45⁄16 110 129 153 23⁄4 23⁄4 23⁄4 23⁄4 415⁄16 125 144 179 511⁄16 7 51⁄16 6 63⁄8 611⁄16 170 www. causing some circuits to have too much flow.6 2.7 2.5 6.5 0./mm Approx.VALVES & AccESSorIES Five Turn Circuit Balancing Valves Solder (GBV-S) & NPT Threaded (GBV-T) Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. depending on their proximity to the source of the flow.Precision contoured channels .0 1./Kg 15 3 ⁄2" ⁄4" 33⁄16 81 9 49⁄16 116 9 23⁄4 70 3 1. See pages 179-181 for installation instructions./mm A In. features & benefits • Multi-turn adjustment • Pressure differential ports on both sides of the valve • Positive shutoff for equipment servicing • Micrometer type handwheel adjustment • Tamper-proof memory stop • Precision instrument function and performance • Easiest and fastest field balancing THROTTLING PERFORMANCE • Ball valves adapted for balancing have only a 90° range from open to closed.11 89 ./mm B In.1 1.5 0. The benefits of a balanced circuit: • Save energy • Make occupied spaces more comfortable • Ensure that pumps operate against the lowest possible pressure • Reduce capital and maintenance costs • Ensure that the system operates according to the intent of the design ⁄2" .5 0.9 2. GBV sweat and threaded balancing valves in Cast Bronze from 1⁄2" to 2" have four full turns./DN(mm) 1 A In.4 20 25 32 40 50 3 ⁄4 83 97 4 ⁄8 51⁄4 55⁄8 57⁄8 2 ⁄4 70 70 70 70 70 1.High strength accurately molded resin • Ergodynamically designed handwheel • Micrometer type adjustment scale • Tamper-proof hidden memory stop 1 ModEL: GBV-S 1⁄2" . Ea. SOLDER & THREADED GBV’S • Sweat and Threaded 1⁄2" to 2" • Unique flow control plug .3 3. Wt.5 2./mm B In.6 0. Lbs.2 5.8 1./DN(mm) 1 ModEL: GBV-t 1⁄2" . Y-style globe valve designed for accurate determination and control of fluid flow to circuits requiring precise balancing. or insufficient flow.com GL-6./Kg Model GBV050VT GBV075VT GBV100VT GBV125VT GBV150VT GBV200VT Nominal Size In. Ea. Wt. GBV-S GBV-T BALANCED CIRCUITS Many systems tend to be overdesigned. If the ATC valve is not included in the kit. If the ATC valve is included pre-assembled in the kit. some additional fittings may be required. 90 www.Integral Union Valve AU . The actual layout required may differ. The components included with each kit are based on the application requirements. coMPonEnt LAYout EXAMPLE CU . Options: • SS – Stainless steel flex hoses with male NPT fittings • Extensions on all 1/4" tapped accessories and lever–style handles (CBV handles are not extended. and heat pumps.) • Automatic temperature control (ATC) factory Installation The HVAC device and rigid piping are not included with the KNX hook-up kit.CBV with Union Adapter UV . Ensure the correct kit is installed at each terminal unit. There are many different KNX hook-up kit component layouts. Layout diagrams are for illustration purposes only. air handling unit coils.Accessory Union SV . ATC connections. reheat coils. Common applications include: fan coils.com GL-7. do not disassemble connections. Check the layout diagram supplied with the kit. it is to be supplied by others and installed on-site.Integral Union Valve Strainer Valve kit contents INCLUDED: 1. However. All layouts are available with stainless steel flex hoses. obtainable from any reputable hydronic system hardware and fitting supplier. to accommodate specific HVAC device connections.anvilintl. or building architecture and obstructions. it has been leak tested. All kits come with components and tailpieces sized to make most connections. Some layouts require ATC valves.12 . specified tailpieces and 1/4" tapped accessories: AU – Accessory Union UV – Integral Union Valve SV – Integral Union Strainer Valve CU – Gruvlok CBV with Union Adapter CA – Gruvlok CBV with Accessory Union 2. VAV box coils. All required brass valves and unions with o-rings.VALVES And AccESSorIES knx series Hydronic Hook-up Kits Gruvlok® KNX Series Hook-up Kits integrate the components required to connect piping to hydronic heating system or chiller system equipment. finned tube radiators. to identify the components required for the installation. and is required for the application. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories knx series au – Accessory Union The AU accessory union combines an o-ring style union with two tapped ports for accessory connection. sv – Strainer Valve The SV integral ball valve strainer combines a full port ball valve. Tapped ports that are not used are fitted with a brass plug. If supplied.CBV with Union Adapter CA .VALVES & AccESSorIES Hydronic Hook-up Kits components The following components are used in KNX hydronic hook-up kits.12 91 . Tailpieces Tailpieces are joined to the corresponding KNX component with a union nut. www. System reliability is improved by reducing connection fatigue due to rigid pipe expansion and contraction. globe-style valve that is equipped with an integral modified venturi and two PT ports. Ensure the air vent is mounted vertically. as required. one tapped port is fitted with a PT Port. CU . Otherwise. Otherwise. these are installed in place of rigid connections between the components and the HVAC device. where no accessory or bypass is specified. Tapped ports are located 90° apart. Refer to the Installation and Operating Instructions supplied with the Gruvlok Five Turn CBV Venturi Circuit Balancing Valve. and multiple tapped ports for accessory connection. (Flex hoses are not shown on the images. By default.) Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. the corresponding port is plugged. The union o-ring is compressed in the component o-ring groove to produce a liquid-tight seal when the union nut is tightened. By default.CBV with Accessory Union cu and ca cbv – Circuit Balancing Valves The CU and CA models combine an Gruvlok® CBV with an o-ring style union. The Gruvlok CBV is a multi-turn. tapped ports are fitted with a PT Port and Manual Air Vent. By default. and multiple tapped ports for accessory connection. located 90° apart. The layout illustration supplied with the kit indicates the components used for that particular installation. for accessory connection. one tapped port is fitted with a PT Port and another with a hose end drain valve.anvilintl. the corresponding port is plugged. o-ring style union. and flow adjustment.com GL-7. a bypass port. SS Stainless Steel Flex Hoses SS flex hoses enable fast and reliable hook-up to hydronic system coils and heat pumps. The CA model includes two 1/4" NPT tapped ports. These units enable precise pressure drop measurement. Hose connections are made on-site with customer supplied sealant and adapters. Otherwise. fixed Cv flow correlation. the corresponding port is plugged. o-ring style union. wye-pattern strainer. Installation speed is increased by avoiding the need for precise rigid run-out pipe length measurement and termination. where no accessory is required. The tailpiece connection may be the same size as the valve body or reduced by one or more sizes. where no accessory is specified. wye-pattern. uv – Union Valve The UV integral ball valve union combines a full port ball valve. 6 Layout CA HD HD UV UV HD SV 2-way atc KNX .13 Layout AU NC 2A/2C NO C CU AC KNX .1 Layout KNX .2 Layout KNX . KNX .4 Layout UV KNX .o.com GL-7.15 Layout HD AU NC 3A/3C NO C CC CU NC 3A/3C NO C CU HD SV SV SV 92 www.9 Layout HD HD AU 2A/2C CU HD AU 2A/2C CU AU 2A/2C CA SV SV SV 3-way atc.12 Layout NC 2A/2C NO CO HD SV C CU AU NC 2A/2C CU AU NO VO CU AU HD SV 3-way atc.c.anvilintl.5 Layout CA KNX .8 Layout KNX .14 Layout HD AU VC KNX . KNX .7 Layout KNX .VALVES And AccESSorIES knx series Hydronic Hook-up Kits KNX Layout Defaults Use this table to determine which KNX Layout most closely resembles your application requirements linear radiator KNX . bypass n. bypass n.11 Layout NC 2A/2C C KNX .3 Layout UV HD UV UV HD CU UV 2A/2C AU HD CU wild coil KNX .12 .10 Layout C NO AO SV HD KNX . 95 1.04 2.5 5.09 1.2 7.9 11.3 3.9 99 104 122 137 170 196 140 142 157 178 196 226 124 140 160 178 216 249 165 178 196 221 241 4.anvilintl.0 4. These kits are available in 1/2" to 2" device sizes and are configured to the system designer’s specifications.7 9.36 1. The CA model also includes two 1/4" NPT tapped ports.59 2./mm Weight Lbs./mm B In.6 5./Kg 15 3 ⁄2 ⁄4 3.6 4.77 0. www. wye-pattern.0 8. for accessory connection.VALVES & AccESSorIES HVAC Hook-up Kits Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Tapped ports that are not used are fitted with a brass plug.CBV with Union Adapter technical data MAX. Each kit is tested.0 20 25 4.5 5.7 8.0 4.1 1 1 4. WORKING PRESSURE: 300 psi (20 bar) MIN. CU .27 3. FLUID TEMPERATURE: 300˚F (150˚C) Non-Boiling MIN. ABS model cu Model CU1 CU2 CU3 CU4 KnX SErIES cu & cA dIMEnSIonS Size In. located 90° apart.5 1 ⁄4 32 40 50 7./mm 3 In.7 9.6 5.9 0. globe-style valve that is equipped with an integral modified venturi and two PT ports. bagged.91 1.6 6.7 7.4 6.6 4.9 2. The Gruvlok CBV is a multi-turn.0 2. ca (cbv accessory) Gruvlok® KNX Series Hook-up Kits integrate the components required to connect piping to hydronic heating system or chiller system equipment.0 1 ⁄4 32 40 50 1 5.com GL-7.0 model ca CU5 CU6 CA1 CA2 CA3 CA4 11⁄2 2 7.9 4.12 93 .9 3.7 5. WORKING PRESSURE: -5 psi (-0. FLUID TEMPERATURE: -4˚F (-20˚C) Non-Freezing FLOW DIRECTION: per Flow Direction Arrow material specifications BODY: Brass STEM & DISC: Brass ELASTOMERS: EPDM HANDLE: Reinforced Nylon./mm 1 A 21⁄2 In.3 5.7 8.9 5.5 7.63 0.3 3. The CU and CA models combine a Gruvlok CBV with an o-ring style union.8 6.8 6.72 2.8 5. fixed Cv flow correlation and flow adjustment.5 6.0 279 6. These units enable precise pressure drop measurement.5 5.4 20 25 1 1 6.7 11.35 bar) MAX.91 1.0 15 3 ⁄2 ⁄4 5.cu (cbv union).7 2.99 GruVLoK KnX cA and cu (ordErInG InForMAtIon) Sample Part Number ––> CA2-S-T2M1-MV-PO-0-SF-R (Default) CA CA CU 2- S- T2M1- MVOption 1 AV MV (default) PT DV PO 00 (CU) PO- 0- SF- R Gruvlok KNX Body Size Body Type Tailpiece 1 F TXXX 2 (default) S (default) 3 4 5 6 Option 2 Extensions Flow Range Application Orientation AV 0 (default) LF R (default) MV 1 SF (default) PT DV PO (default) 00 (CU) See Configuration Options on page 98.5 Option 2 CA5 CA6 11⁄2 2 8.5 117 124 135 142 150 170 117 124 135 142 150 170 4. tagged and delivered to the building site ready for installation. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories knx series .0 7. 74 DN15 3 1. please see our website.29 11⁄4" DN32 4. B = BSPP (ISO-228) 94 www. STEM AND DISK: Brass alloy CW602N Dezincification Resistant (DZR) to EN12165 per ISO-6509 ELASTOMERS: EPDM HANDWHEEL: Reinforced Nylon.98 0.4 300 (˚F) 149 (˚C) technical data CONNECTION: Model CBV-VS Solder Joint.69 0.com GL-7.3 6. S = Sweat.57 0.88 note: In model number. T = NPT. When the minimum design flow requirement of each circuit is met.9 3. For other models. The CA model also includes two 1/4" NPT tapped ports.29 22.41 0.20 11⁄2" DN40 9.anvilintl. typical applications Gruvlok® circuit balancing valves are used to regulate the flow of hydronic fluid in heating and chiller system piping circuits.VALVES And AccESSorIES knx series . located 90° apart.02 1.98 81. the system is considered. Tapped ports that are not used are fitted with a brass plug.11 0.07 11.92 5. with the system operating at maximum design flow.13 13. (X) = Connection Type.08 9.99 0.60 3.08 0. Suitable liquids include water.21 4./mm Minimum Flowrate gpm/lps Maximum Flowrate gpm/lps Flowrate Coefficients Cv/Kv CBV050V(X)CR-LF CBV075V(X)CR-LF CBV050V(X)CR CBV075V(X)CR CBV100V(X)CR CBV125V(X)CR CBV150V(X)CR CBV200V(X)CR ⁄2" LF ⁄4" LF 1 0.97 1.57 0.59 DN15 LF 3 0.03 3. Model CBV-VT Threaded Joint.05 0.47 DN20 1" DN25 4.01 10. for accessory connection.02 2. and up to 50/50 water/glycol mixtures (both ethylene and propylene glycol).57 50.69 20.16 40.45 12. BONNET.30 2" DN50 15.87 5.2 13.70 34.98 0.psi 200 150 100 50 0 -18 50 10 100 150 38 66 Temperature 200 93 250 121 20.circuit balancinG valves HVAC Hook-up Kits dEZIncIFIcAtIon rESIStAnt NOTE: These instructions pertain only to Dezincification Resistant models having red and blue PT Port cap retainers.20 1.93 DN20 LF ⁄2" ⁄4" 1.bar 17.12 .8 10. ABS FLoW rAtE rAnGES Valve Model 1 Size In.22 0.02 0. maximum operatinG parameters 300 250 Pressure . "balanced".adjustment.58 13. Model CBV-VB Threaded BSPP MAX.26 0. WORKING PRESSURE: 300 psi/20 bar (PN20) OPERATING TEMPERATURE RANGE: -4˚F to 300˚F (-20˚C to 150˚C) material specifications BODY.15 23.7 Pressure .20 2.31 41.12 0.76 0.07 3. tagged and delivered to the building site ready for installation.2 1.4 36 1. www.5 64 2./mm A FPT In. the corresponding port is plugged.36 2 50 3./mm 1 MPT In.6 66 2.12 95 .2 56 2.35 bar) MAX. Each kit is tested.0 76 3.2 0. Otherwise.45 15 3 2. tapped ports are fitted with a PT Port and Manual Air Vent.0 0.6 66 3.8 71 3.0 76 3.54 20 1 25 2.0 76 2.0 76 3. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories knx series . By default.0 76 2.0 1.9 48 1. AU5 AU6 11⁄2 40 3.3 58 3.1 79 2.1 53 2.4 86 2.anvilintl.VALVES & AccESSorIES HVAC Hook-up Kits Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs./mm Sweat In.00 Both option ports are 1/4" NPT tapped. it is installed in the Option 1 position./Kg AU1 AU2 AU3 AU4 ⁄2 ⁄4 2. If an air vent is specified.73 11⁄4 32 3. WORKING PRESSURE: 600 psi (41 bar) MIN.5 2. Tapped ports are located 90° apart on a rotational axis. WORKING PRESSURE: -5 psi (-0. FLUID TEMPERATURE: 300˚F (150˚C) Non-Boiling MIN. bagged.5 64 2.6 0.04 GruVLoK KnX Au (ordErInG InForMAtIon) Sample Part Number ––> AU2-S-T2M1-MV-PT-0-S (Default) AU Gruvlok KNX AU 2Body Size 1 2 (default) 3 4 5 6 SBody Type M F S (default) T2M1Tailpiece TXXX MVOption 1 AV MV (default) PT DV PO PTOption 2 AV MV PT (default) DV PO 00 (default) 1 S S (default) R Extensions Application Orientation See Configuration Options on page 98.au (accessory union) Gruvlok® KNX Series Hook-up Kits integrate the components required to connect piping to hydronic heating system or chiller system equipment.2 56 1. it is installed in the Option 2 position./mm B In.1 53 1.com GL-7. where no accessory is required./mm Weight Lbs.8 97 4. These kits are available in 1/2" to 2" device sizes and are configured to the system designer’s specifications. FLUID TEMPERATURE: -4˚F (-20˚C) Non-Freezing FLOW DIRECTION: Bi-directional material specifications BODY: Brass ELASTOMERS: EPDM KnX SErIES Au dIMEnSIonS Model Size In. The AU accessory union combines an o-ring style union with two tapped ports for accessory connection. technical data MAX.1 53 2. If a PT Port is specified.0 51 2.4 61 1.8 46 1. 86 20 1 25 3.2 56 3.49 GruVLoK KnX uV (ordErInG InForMAtIon) Sample Part Number ––> UV2-S-T2S2-PT-PO-PO-0-S (Default) UV UV 2- S- T2S2- PTOption 1 AV MV PT (default) DV PO POOption 2 AV MV PT DV PO (default) POOption 3 0- S S (default) R Gruvlok KNX Body Size Body Type Tailpiece 1 F TXXX 2 (default) S (default) 3 4 5 6 Extensions Application Orientation AV 0 (default) MV 1 PT DV PO (default) See Configuration Options on page 98. bagged.com GL-7.anvilintl.6 117 5. WORKING PRESSURE: -5 psi (-0.9 74 3.6 91 4.2 132 2.8 147 3./Kg UV1 UV2 UV3 UV4 ⁄2 ⁄4 2.3 2.0 1. technical data MAX. Otherwise. one tapped port is fitted with a PT Port. o-ring style union and multiple tapped ports for accessory connection./mm B In.77 All option ports are ¼" NPT tapped. If a drain valve is specified. the corresponding port is plugged.9 1.6 1.2 56 1.9 74 3.5 89 5. FLUID TEMPERATURE: 300˚F (150˚C) Non-Boiling MIN.7 43 1.9 0. Full Port VALVE SEAT: PTFE ELASTOMERS: EPDM HANDLE: Chrome Plated Steel.8 173 4.73 15 3 3.35 bar) MAX./mm 1 A FPT In. 96 www. These kits are available in 1/2" to 2" device sizes and are configured to the system designer’s specifications./mm Weight Lbs.3 84 3.uv (inteGral ball valve union) HVAC Hook-up Kits Gruvlok® KNX Series Hook-up Kits integrate the components required to connect piping to hydronic heating system or chiller system equipment. UV5 UV6 11⁄2 40 5. where no accessory is specified.40 2 50 6. Each kit is tested. WORKING PRESSURE: 600 psi (41 bar) MIN.0 102 7.36 11⁄4 32 4.7 3.VALVES And AccESSorIES knx series .12 .7 94 2.1 104 2.0 152 6. tagged and delivered to the building site ready for installation. By default. it is installed in the Option 2 position. FLUID TEMPERATURE: -4˚F (-20˚C) Non-Freezing FLOW DIRECTION: Bi-directional material specifications BODY: Brass BALL VALVE: Chrome Plated Brass./mm Sweat In. Plastisol Coated KnX SErIES uV dIMEnSIonS Model Size In. it is installed in the Option 1 position.1 130 5.2 81 1. If an air vent is specified. The UV integral ball valve union combines a full port ball valve. where no accessory or bypass is specified.36 11⁄4 32 7.anvilintl.77 All option ports are 1/4" NPT tapped. o-ring style union.50 FPT 0. it is installed in the Option 2 position. See Dimensions and Weights for the bypass port size.50 FPT 0. www. tagged and delivered to the building site ready for installation.7 3.75 FPT 0.9 0. one tapped port is fitted with a PT Port and another with a hose end drain valve.3 185 3. Each kit is tested./mm Bypass Port In. Weight Lbs.5 140 15 3 0.sv (inteGral ball valve strainer) Gruvlok® KNX Series Hook-up Kits integrate the components required to connect piping to hydronic heating system or chiller system equipment.6 1. These kits are available in 1/2" to 2" device sizes and are configured to the system designer’s specifications.12 97 .00 FPT 1. WORKING PRESSURE: -5 psi (-0.VALVES & AccESSorIES HVAC Hook-up Kits Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. wye-pattern strainer and multiple tapped ports for accessory connection.75 FPT 1.P1-0-S Gruvlok KNX (Default) SV 2Body Size S- T2S2- PT- DV- PO- PO- P1- 0- S Body Application Tailpiece Option 1 Option 2 Option 3 Option 4 Bypass Extensions Type Orientation 1 F TXXX AV DV (default) PT PT 00 0 (default) S (default) 2 (default) S (default) MV PO PO (default) PO (default) P1 (default) 1 3 PT (default) P2 4 PO 5 6 See Configuration Options on page 98. it is installed in the Option 1 position.4 239 8.0 1. technical data MAX.8 224 7.4 213 5. WORKING PRESSURE: 600 psi (41 bar) MIN.73 5./Kg SV1 SV2 SV3 SV4 ⁄2 ⁄4 5.7 196 7.35 bar) MAX. If an air vent is specified.7 221 9. bagged.7 170 7. FLUID TEMPERATURE: -4˚F (-20˚C) Non-Freezing FLOW DIRECTION: Body to Union Connection material specifications BODY: Brass STRAINER: 20 Mesh Stainless Steel BALL VALVE: Chrome Plated Brass. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories knx series . By default. FLUID TEMPERATURE: 300˚F (150˚C) Non-Boiling MIN. SV5 SV6 11⁄2 40 8. Plastisol Coated KnX SErIES SV dIMEnSIonS Model Size A In.86 20 1 25 6.8 147 1. Otherwise./mm 1 B FPT In./mm Sweat In.2 132 5. the corresponding port is plugged. The SV integral ball valve strainer combines a full port ball valve.40 2 50 9.9 175 3.50 FPT 0./mm C In.2 132 5.4 239 10.0 127 5.3 185 6. If a drain valve is specified.9 1. Full Port VALVE SEAT: PTFE ELASTOMERS: EPDM HANDLE: Chrome Plated Steel.3 2.1 180 7.6 142 5.3 262 8.com GL-7.49 GruVLoK KnX SV (ordErInG InForMAtIon) Sample Part Number ––> SV SV2-S-T2S2-PT-DV-PO-P0. 000 2.452 0.000 2.110 0.100 1.000 3.250 3.000 2. B In. Model number A (Body) In.800 1.500 2.380 1.000 2.000 3.800 1.460 1.160 ⁄2 ⁄2 3 ⁄4 1 ⁄2 3 ⁄4 1 3 ⁄4 1 11⁄4 1 11⁄4 11⁄2 11⁄4 11⁄2 2 1 1 98 www.005 1.047 3.940 0.000 ⁄2 1 ⁄2 3 ⁄4 1 ⁄2 3 ⁄4 1 1 ⁄2 3 ⁄4 1 11⁄4 3 ⁄4 1 11⁄4 11⁄2 1 11⁄4 11⁄2 2 1 T1S0 T1S1 T1S2 T2S0 T2S1 T2S2 T3S1 T3S2 T3S3 T4S2 T4S3 T4S4 T5S3 T5S4 T5S5 T6S4 T6S5 T6S6 ⁄2 1 ⁄2 1 ⁄2 3 ⁄4 3 ⁄4 3 ⁄4 1 1 1 11⁄4 11⁄4 11⁄4 11⁄2 11⁄2 11⁄2 2 2 2 1 0.650 1.890 2.760 2.790 0.520 1.170 1.000 1. C (FPT) In. Description In.800 1.000 3.VALVES And AccESSorIES knx series .250 0.confiGuration options HVAC Hook-up Kits BodY SIZE Size 1 2 3 4 5 6 3 BodY tYPE Type F S Description Female NPT Sweat (default) Type AV MV PT DV P0 P1 P2 oPtIon / BYPASS Description In.446 ⁄8 1 ⁄2 3 ⁄4 3 ⁄8 1 ⁄2 3 ⁄4 1 ⁄2 3 ⁄4 1 3 ⁄4 1 11⁄4 1 11⁄4 11⁄2 11⁄4 11⁄2 2 3 T1F1 T2F1 T2F2 T3F1 T3F2 T3F3 T4F2 T4F3 T4F4 T5F3 T5F4 T5F5 T6F4 T6F5 T6F6 ⁄2 3 ⁄4 3 ⁄4 1 1 1 11⁄4 11⁄4 11⁄4 11⁄2 11⁄2 11⁄2 2 2 2 1 0.330 1.800 0.000 2. B In.com GL-7.225 1.990 1. Model number A (Body) In.563 1.anvilintl.500 2.000 1.500 1.500 2.563 1.000 1./mm 1 ⁄2 13 ⁄4 (default) 19 EXtEnSIonS Type 0 1 Description In.850 1. 1 25 11⁄4 32 No Extensions (default) Handle / Options extended 13⁄4" for access through Insulation Automatic Air Vent Manual Air Vent PT Port (default) Drain Valve with Hose End and Retained Cap 1 ⁄4" Brass Plug (default) 1 ⁄2" Brass Plug 3 ⁄4" Brass Plug 11⁄2 38 APPLIcAtIon orIEntAtIon Type R S 00 Description Body connects to Return Body connects to Supply (default) Not Applicable 2 50 tAILPIEcE Model number A (Body) In.12 .775 2. T1M1 T2M1 T2M2 T3M1 T3M2 T3M3 T4M1 T4M2 T4M3 T4M4 T5M2 T5M3 T5M4 T5M5 T6M3 T6M4 T6M5 T6M6 ⁄2 3 ⁄4 3 ⁄4 1 1 1 11⁄4 11⁄4 11⁄4 11⁄4 11⁄2 11⁄2 11⁄2 11⁄2 2 2 2 2 1 1.650 0.750 0. B In. C (MPT) In. C (Sweat) In.500 2.430 0.900 1.620 1. The spring closes the disc as the line flow approaches zero in order to prevent flow reversal & water hammer. 3. Line pressure of approximately 1⁄4 PSI will open the disc.12 99 . • Valve seat can be changed in the field without use of special tools • Low pressure drop due to “Y” pattern valve design • Valve Cv designed to ASHRAE flow recommendations for quiet system operation • Drip-tight shut off valve smoke development rating of 50 or less www. one valve — 1. we recommend that a Gruvlok® Circuit Balancing Valve be installed downstream from the FTV valve. features & benefits • Three functions. 2. If precision accuracy is required. Spring-closure design. See pages 175-178 for installation instructions and flow data. oPErAtIon: The Model FTV Tri-Service Valve operates automatically and silently. These lugs. flow control valve and shut off valve. Flow measurement (where an approximate indication is acceptable) is obtained by flow measuring ports on each side of the valve seat. Pressure differential is easily recorded using differential pressure measurement devices. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories ftv-s (straight) & ftv-a (angle body) SErVIcE rEcoMMEndAtIonS: The Model FTV-S & FTV-A Tri-Service Valve is primarily designed for installation in pump discharge piping where it functions as a spring loaded silent check valve.anvilintl.com GL-7. FEAturES: The unique convertible body design permits the valve to be changed on site from the straight to the angle configuration. Non-slam check valve. Flow throttling valve • Reduced field installation and material cost • Stainless steel spring • High-strength resin seat EPDM for 8" and larger • Anti-rotation lugs on the inlet and outlet.VALVES & AccESSorIES Tri-Service Valve Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. The flow through the valve can be adjusted from bubble tight shut off to full flow by the threaded rising stem. combined with the Gruvlok 7401 Rigidlok Coupling or the Gruvlok flange adapter provides for a ridged rotation free installation • Flow measurement and pump throttling capabilities • Temperature measurement capability • Spring-closure design check valve prevents gravity or reverse circulation when pump is not operating • Bonnet “O” Ring can be replaced under full system pressure by back seating of valve stem • Suitable for maximum working pressure to 375 psi (26 bar) and temperatures to 230°F. (110°C). ASTM E 136 with a flame spread rating of 25 or less and a smoke development rating of 50 or less./mm Approx./mm D In./mm 125/150 PSI G In./mm A In.D.D./mm Flange C In./mm Flange Approx./mm A In./Kg 2 /2 1 12 305 7 178 2 /4 3 1 25 2 /16 9 7 178 7 /2 1 19 9 2 /2 1 7 /8 3 7 178 2 /4 3 4 /8 5 1 25 2 /16 9 7 178 7 /2 1 19 9 65 70 65 191 65 187 70 117 65 191 3 80 12 305 713/16 198 27/16 62 1 25 3 80 71/2 191 81/4 210 24 11 3 80 83/16 208 713/16 198 27/16 62 37/8 98 1 25 3 80 71/2 191 81/4 210 24 11 4 100 14 356 8 203 3 80 11/4 32 37/16 87 91/4 235 10 254 42 19 4 100 95/8 244 8 203 3 80 43/8 111 11/4 32 37/16 87 91/4 235 10 254 42 19 5 125 171/2 445 101/8 257 35/8 92 11/4 32 415/16 125 10 254 11 279 81 37 5 125 12 305 359 481 101/8 257 264 476 35/8 92 51/2 140 11/4 32 415/16 125 10 254 11 279 81 37 6 150 2011/16 525 716 103/8 264 579 47/16 113 2 51 57/8 149 11 279 121/2 318 120 54 6 150 141/8 103/8 47/16 113 144 65/8 168 2 51 57/8 149 11 279 121/2 318 120 54 8 200 283/16 2213/16 30 762 511/16 144 21/4 57 77/8 200 131/2 343 15 381 300 136 8 200 1815/16 183/4 511/16 205/16 516 611 93/16 233 21/4 57 77/8 200 131/2 343 15 381 300 136 10 250 285/8 727 69/16 167 21/4 57 915/32 241 16 409 171/2 445 450 204 10 250 24 610 667 69/16 167 93/4 248 21/4 57 915/32 241 16 409 171/2 445 450 204 12 300 381/16 967 325/8 829 75/8 194 21/4 57 125/8 321 19 483 201/2 521 850 390 12 300 241/16 261/4 75/8 194 14 356 21/4 57 125/8 321 19 483 201/2 521 860 390 See Page 51 for O./mm E In./mm F In./mm B (fully open) In.11 ./mm E In. Size material specifications BODY: Ductile Iron ASTM A 536 Grade 65-45-12 DISC: Bronze ASTM B 584 C-84400 STEM: Stainless Steel ASTM A 582 Type 416 SEAT: High Strength Engineered Resin SPRING: Stainless Steel ASTM A 302 “O” RINGS: BUNA COUPLINGS/FLANGES: Ductile Iron ASTM A 536 Grade 65-45-12 with EPDM2 Gaskets (Optional) INSULATION: Optional1 NOTE 1: Optional pre-formed insulation is available to meet ASTM D 1784 Class 14253-C.VALVES And AccESSorIES ftv-s (straight) & ftv-a (angle body) Tri-Service Valve B D B C G A G C A E (diameter) F E (diameter) F ModEL FtV-S (StrAIGHt) Connection Size In. NOTE 2: EPDM is not suitable for oil service. NOTE: For temperatures between 230°F and 300°F (110°C and 149°C) specify Viton Elastomers Gruvlok Anti-Rotation Lugs Flow Indicator Scale Stainless Steel Spring Flow/Temperature Measurement Ports Drain Connections (on opposite side) Gruvlok Anti-Rotation Lugs Bonnet “O” Ring Stainless Steel Stem High Strength Resin Seal EDPM for 8" and larger Bronze Disc 100 www.com GL-6. Each Lbs./mm Flange C In./mm 125/150 PSI G In. Wt./mm Lbs. Size See Page 51 for O. MEA #7-87./mm ModEL FtV-A (AnGLE) Flange 250/300 PSI G In.anvilintl./mm F In. PSI Each G In./mm B (fully open) In./Kg Connection Size In. 250/300 Wt. range) Grade “EP” EPDM -40°F to +250°F (service temp. Bolts and nuts are provided zinc electroplated as standard. PRESSURE DROP .12" Ductile iron conforming to ASTM A 536.11 TAP SIzES: 2"-4" – 1⁄2 NPT.12 101 .18" Carbon steel pipe conforming to ASTM A 53 STRAINER BASKET: Stainless steel type 304 bar and woven wire screen.anvilintl. ACCESS COUPLING & END CAP: 2" . oval-neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. twin-fold strainer basket provides more than 100% of the projected pipe area for open flow through the strainer screen which results in excellent flow performance across the strainer. COATING: 2" . range) Other options available upon request.PSI FLOW CHARACTERISTICS FLOW (GPM) NOTE: Most U. 10"-18" – 1 NPT. Gruvlok Strainers are designed and tested to ensure long term.12" Ductile iron conforming to ASTM A 536.18" Low carbon steel conforming to ASTM A 53 BOLTS & NUTS: Heat treated. Grade 65-45-12 14" . Flow data values are based on flow of clean water at ambient temperatures. replace the strainer screen. Other mesh sizes available on request. DRAIN PLUG: Carbon steel square head plug conforming to ASME B16.3" and 6 mesh in sizes 4" . 7260 The Fig.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563. piping engineers specify system startup instructions for new systems which include removing and cleaning the strainer screen after system flushing of main piping before the system is put into normal operation. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 5"-8" – 3⁄4 NPT.Rust-inhibiting paint — color: orange (standard) Hot Dip Galvanized conforming to ASTM A 153 (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. is approximately twice as great as that of a clean strainer. COUPLING GASKETS: Elastomer properties as designated by ASTM D 2000 Grade “E” EPDM -40°F to +230°F (service temp. Strainer baskets need a routine maintenance program to maintain efficiency and to prevent excess pressure drop caused by a clogged screen. After flushing.com GL-7.18".12" . 50% clogged. reliable service in working pressures up to 750 psi (51. material specifications BODY: 2" . 12 mesh in sizes 2" . depending on size and the pressure rating of the connecting coupling. Grade 65-45-12 14" . The pressure drop across a strainer. compact and hydraulically efficient means of protecting valuable piping system components.VALVES & AccESSorIES Tee Strainer Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. The in-line. www.S. 7260 Tee Strainer provides an economical.7 bar). 7260 Tee Strainer E to E Y C to O X NOTE: The above illustration shows the required orientation of the Rigidlok access coupling for assembly with a grooved-end flange.0 20. 102 www.6 3 80 3.3 750 51.9 750 51.1 500 34.9 400 27.000 355.anvilintl.7 10 254 61⁄8 156 57⁄8 149 83⁄8 213 71⁄4 184 19. In. Maximum system working pressure is dependent upon the couplings used for installation and the pressure capability of other system components.500 88.7 31 787 151⁄2 394 201⁄2 521 243⁄8 619 241⁄2 622 400 181.5 18 457 103⁄8 264 127⁄8 327 171⁄8 435 141⁄4 362 133 60.7 24 610 12 305 181⁄8 460 221⁄4 565 20 508 350 158. FIGurE 7260 tEE StrAInEr Nominal Size In.2 300 20.com GL-7.7 13 330 75⁄8 194 81⁄8 206 111⁄8 283 93⁄4 248 45.7 61⁄2 165 41⁄4 108 31⁄2 89 57⁄8 149 43⁄8 111 6.4 16 400 16.4 * Maximum working pressure is based upon the performance capability of the Gruvlok Strainer.750 323.VALVES And AccESSorIES fiG. Wt.3 750 51.7 81⁄2 216 51⁄4 133 43⁄4 121 7 178 6 152 13.4 8 200 8./mm Y In.000 457. Ea.8 10 250 10.18" Fabricated Not for use with copper systems. Lbs./mm X In.0 2.12 .8 18 450 18.000 406.7 11 279 65⁄8 168 7 178 101⁄8 257 81⁄4 210 30./Kg 2 50 2.4 151⁄2 394 91⁄8 232 101⁄2 267 141⁄8 359 12 305 79. 14" .500 114.6 300 20.875 73.375 60.6 5 125 5.8 14 350 14.750 273.0 5.6 6 150 6.4 300 20.0 8.1 600 41.D.7 22 559 123⁄4 324 161⁄8 410 201⁄2 521 171⁄4 438 272 123./mm Maximum* Working Pressure PSI/bar E to E In.625 168.0 35.3 750 51.7 21⁄2 65 2./DN(mm) O./mm Basket Removal Clearance Approx.6 20 508 113⁄8 289 15 381 191⁄8 486 161⁄4 413 187 84.563 141.0 750 51./mm C to O In.0 13.625 219.3 12 300 12.9 4 100 4.3 750 51.0 3.7 71⁄2 191 43⁄4 121 4 102 61⁄2 165 51⁄8 130 8. FIGurE 758 G GrooVEd-End “WYE” StrAInEr Cv 1. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories model 758G INDIVIDUALLY HYDROSTATICALLY TESTED flow data: NOTE 1. (When ordering. oil and gas piping to provide economical protection for pumps.563 141.625 168.0 213.1 215⁄8 549 151⁄2 394 2 51 223⁄4 577 205. compressors. valves./Kg 2 50 2. 50% clogged./mm B In. conStructIon All covers have an NPT blowoff outlet at location “C”.0 9 8 7 6 5 4 3 2 Nominal Size In. www./mm Approx. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. advise when strainers are to be mounted in vertical piping. In. is approximately twice as great as that of a clean strainer.0 19.2 65 FLOW RATE . GruVLoK StrAInEr BASKEt Furnished as standard in sizes 8" (43 mm) and larger.VALVES & AccESSorIES Grooved-End “Wye” Strainer SErVIcE rEcoMMEndAtIonS For use in water. holes 5" ./mm 1 C D In.500 88.750 273.375 60.s. the cover can be rotated to position the blowoff at the lowest point.0 8. A one-quarter turn securely locks the screen in its seat and frees the serviceman for securing the cover flange to the body of the strainer.3 181⁄2 470 131⁄2 343 2 51 20 508 112.6 C (NPT) 12 300 12.12" Type 304 Stainless Steel 1⁄8" (3.1 5 125 5.3 6 150 6. NOTE 2. COUPLING: Ductile iron ASTM A 536 Grade 65-45-12 SIZE (inches) 1 ⁄2 1 2 2 ⁄2 3 1 4 5 6 8 10 12 PRESSURE DROP .625 219.3 155⁄8 396 111⁄4 286 2 51 17 432 80./mm Plug Size In. meters.875 73.i.9 101⁄8 257 7 178 1 25 10 254 23. Blowoff outlets are not normally furnished with plugs. Self-cleaning is done by opening the valve or plug connected to the blowoff outlet. The pressure drop across the diffuser basket strainer.12 103 .) BLoWoFF outLEtS Tapped NPT size specified in the dimension table. Each Lbs.S.500 114. Flow data values are based on flow of clean water at ambient temperatures. 3 80 3.com GL-7.2mm) dia.4 A 4 100 4.0 10 250 10.3 121⁄8 308 81⁄4 210 11⁄2 38 12 305 42. piping engineers specify system startup instructions for new systems which include removing the pre-filter screen after system flushing of the main piping before the system is put into normal operation.0 125.0 5.1 10 2 3 4 5 6 7 8 9100 2 3 4 5 6 7 8 9 1000 2 3 4 5 6 7 2.4" Type 304 Stainless Steel 1⁄16" (1./DN(mm) O.9 30 762 213⁄4 552 2 51 30 762 470.8 B D Screen Removal 8 200 8. GROOVED END “Y” TYPE STRAINERS 10 9 8 7 6 5 4 3 2 Working Pressures Non-Shock 640 PSI @ 150°F (45 Bar @ 65°C) material specifications BODY & COVER: Ductile Iron ASTM A 395 Grade 60-40-18 FLAT GASKETS: Non-asbestos SCREEN: 2" .m. Bosses at the inlet and outlet flanges are provided for gauge taps.4 25 21⁄2 . Suction Diffuser baskets need a routine maintanence program to maintain system efficiency. Most U. Recommended standard perforations are listed below in the material specifications. Wt. traps and similar equipment.0 50.D.g.0 93.0 10 254 61⁄2 165 1 25 93⁄4 248 18. holes.anvilintl./mm Dimensions A In. Not for use with copper systems. Maximum system working pressure is dependant upon the couplings used for installation and the pressure capacity of other system components. Mesh lining is available in all alloys for extra fine straining.0 36.0 10.3 77⁄8 200 51⁄4 133 ⁄2 7 178 12.p.2 * Maximum working pressure is based upon the performance capability of the Gruvlok® Strainer.6mm) dia.750 323.1 253⁄4 654 181⁄2 470 2 51 28 711 277. Contact an Anvil Representative for other applications. ScrEEnS Standard screens for Y-Strainer are perforated 304 Stainless Steel with spot welded seam.p. A recessed seat in the cover ensures accurate screen alignment. The Strainer can be installed quickly and easily with two mechanical couplings and the straight flow through design provides for lower pressure drop. 3" & 4": 1" tapped with plug.4 12.500 88.1 300 20. Cleaning and maintenance of the screen can be accomplished easily by removing the coupling.4 22.0 225.2 126.000 406. This strainer features a stainless steel screen that is secured with an end cap and mechanical coupling.500 114.3 300 20.0 190. Strainer baskets need a routine maintenance program to maintain efficiency and to prevent excess pressure drop caused by a clogged screen.375 60.625 219.anvilintl.3 300 20./mm C In./mm Plug Size In.7 113⁄4 298 811⁄16 231 51⁄16 129 1 25 18./mm B In.12" Type 304 Stainless Steel to ASTM A 240 ./Kg 2 50 2.6 mm) perforations 4" .3 300 20.0 12 3 80 A 3.7 30 762 24 609 143⁄8 366 11⁄2 38 277.000 355.7 40 1016 2915⁄16 760 187⁄8 480 11⁄2 38 418.0 6 150 B 6. Values for flow of water at +60°F (+16°C) Where: Q = Flow (GPM) CV = flow coefficient ∆P = Pressure drop (PSI) FIGurE 768 G GrooVEd-End “WYE” StrAInEr Nominal Size In.9 300 20.VALVES And AccESSorIES model 768G Globally Sourced Grooved-end “Wye” Strainer The Grooved-end Wye-Strainers are designed to strain debris and foreign matter from piping systems and thus provide inexpensive protection for costly pumps. Wt. ULC. The Strainer is suitable for vertical and horizontal installations.6 300 20. • Warning: Piping systems must always be depressurized and drained before attempting disassembly and or removal of any components.6 83. 6" ./mm 1 D Cv Values 59 92 162 284 410 770 1010 1800 2800 4600 5800 Approx./DN(mm) O.2 mm) perforations Other perforations are available upon request COUPLING: Ductile iron ASTM A 536 Grade 65-45-12 GASKET:* EPDM Temperature range -40°F .1⁄8" (3.3 4.7 181⁄2 470 141⁄16 357 85⁄8 219 11⁄2 38 70.750 323.0 12 300 12.7 141⁄4 362 105⁄8 281 65⁄8 168 1 25 26.2 4 100 4.875 73.0 16 400 16.4 32. material specifications BODY: Ductile iron ASTM A 536 Grade 65-45-12 END CAP: Ductile iron ASTM A 536 Grade 65-45-12 SCREEN:* 2" .0 55.0 10 250 C Screen Removal 10.0 5 125 5. • Pressure ratings listed are CWP (cold water pressure) or maximum working pressure within the service temperature range of the gasket used in the coupling.2 6.0 300 20.7 103⁄4 273 713⁄16 211 413⁄16 122 13.3 300 20.625 168. 104 www. and/or FM as testing conditions and test pipes differ.12 . • For one time field test only the maximum joint working pressure may be increased 11⁄2 times the figures shown.9 300 20.1⁄16" (1.com GL-7. 40 steel pipe with roll grooves to ANSI C606-97 specifications.7 27 686 209⁄16 522 125⁄8 320 11⁄2 38 182.12": 11⁄2" tapped with plug * Custom screens and/or gaskets are available upon request.3" Type 304 Stainless Steel to ASTM A 240 .0 D Plug Size Not for use in copper systems. In. meters and other components.2 12 1 21⁄2 65 2.7 42 1067 309⁄16 777 19 483 11⁄2 38 495.0 8.0 8 200 8.563 141. This rating may occasionally differ from maximum working pressures listed and/or approved by UL.750 273./mm Working Pressure PSI/bar Dimensions A In.0 14 350 14.D. • Maximum working pressure and end loads listed are total of internal and external pressures and loads based on Sch.+230°F (-40° to 110°C) Nitrile Temperature range -20°F to 180°F (-29° to 82°C) BLOW DOWN PORT: 2" & 21⁄2": 1⁄2" tapped with plug.4 300 20.7 161⁄2 419 13 330 103⁄16 258 1 25 46.1 300 20.7 93⁄4 248 71⁄8 192 49⁄16 116 ⁄2 ⁄2 9.7 24 610 177⁄8 454 113⁄16 284 11⁄2 38 121. Each Lbs. 12 105 . oil-free air and many other chemical services. Grade 65-45-12.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563. Sizes 10" x 10" through 16" x 14": Carbon steel . diluted acids.375" standard weight wall conforming to ASTM A 53.5. streamlines the flow. For hot water applications the use of Gruvlok Extreme Temperature lubricant is recommended.6 11 /2" 2. Suction Diffuser baskets need a routine maintanence program to maintain system efficiency. Pre-Filter: Stainless steel type 304 screen . oil-free air and many other chemical services. PIPE SuPPort LuG StAndArd FLOW CHARACTERISTICS 2.0 4. COATINGS: Rust inhibiting paint Color: ORANGE (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. METRIC BOLTS & HEAVY HEX NUTS: Heat treated. #16 perforated plate with 3⁄16” diameter holes. NSF-61 Certified for cold and hot water applications up through 12". Contact an Anvil Representative for more information HOUSING: Sizes 21⁄2" x 2 1⁄2" through 10" x 8": Carbon steel Schedule 40 conforming to ASTM A 53.2 60 100 200 400 600 1000 2000 4000 0.62 FLoW dAtA: HEAD LOSS IN FT. Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service.85 1. piping engineers specify system startup instructions for new systems which include removing the pre-filter screen after system flushing of the main piping before the system is put into normal operation. SAVES LABor And MAtErIAL: The lightweight compact design is easily installed with no need for welding. alkalies solutions. 7250 Gruvlok Suction Diffuser protects your pump and saves you money on your overall installed cost while offering you these advantages: SAVES SPAcE: Mounts directly to the pump inlet. Most U. NOT FOR USE IN PETROLEUM APPLICATIONS. air with oil vapors and vegetable and mineral oils. (51% open area). STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are also available. diluted acids. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. OF WATER NOTE 1. IMProVES PuMP PErForMAncE: The one-piece diffuser vane and strainer design reduces flow turbulence. 7250 The Fig.anvilintl.com GL-7. DRAIN & GAGE PLUGS: Carbon steel square head plugs conforming to ASME B16.92 0.0 0. www.46 FLOW THROUGH SUCTION-DIFFUSER GPM material specifications ANSI BOLTS & HEAVY HEX NUTS: Heat treated. PRESSURE DROP IN PSI 4" 5" x x 4" 4 5" x " & 6" x4 5" & 6" x " 5" 6" x 8" & 8" x 6" 0" 2" & 16" 12" x 1 x1 4" 2" 1.S. NOT FOR USE IN HOT WATER OR HOT AIR.8 0. is approximately twice as great as that of a clean strainer. NOTE 2.38 "x x8 10" 8" & 8" x 10" x1 " 0" & 1/2 4" x &2 /2" 3" & 3" x 21 3" x 0.VALVES & AccESSorIES Suction Diffuser Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. FLANGES: Carbon steel class 150# conforming to ASME B 16. COUPLINGS: Ductile Iron conforming to ASTM A 536. Flow data values are based on flow of clean water at ambient temperatures. DIFFUSER BASKET: Stainless steel type 304. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.16 mesh. and traps any hazardous foreign material to better protect your pump. The pressure drop across the diffuser basket strainer. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Bolts and nuts are provided zinc electroplated as standard. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service.4 14" x1 12" x1 3" 0. alkalies solutions.69 0. Grade B. (removable). oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. Grade B. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. NOT FOR USE IN PETROLEUM APPLICATIONS.31 1.11. 50% clogged. /mm OAW Flange O. PSI/bar Approx.7 20. Pipe Support .3 173.1 104.000 x 12. Product must be supported by pipe supports (supports not included).484 4.5 15.1 12 12 10 12 10 11 171⁄4 24 ⁄4 616 616 195⁄8 20 ⁄2 521 521 233⁄4 34 /4 870 870 36 36 19 695 695 300 300 382 382 14 x 10 14 x 12 14.1 151⁄4 15 ⁄4 387 241⁄2 24 ⁄2 622 711 711 914 914 914 991 991 173⁄4 17 ⁄2 445 131⁄2 343 1 193⁄4 19 ⁄4 502 53⁄8 5 ⁄8 3 266 266 300 300 190 200 10 x 8 10 8 9 13 ⁄2 343 406 406 483 406 483 533 533 10 x 10 10.3 x 141. Contact an Anvil Rep.7 20.625 x 6. 7250 Suction Diffuser OAH C-E FIG.1 323.1 x 141.077 1.500 6.1 7 ⁄4 13 ⁄4 337 21 ⁄2 546 14 ⁄4 375 16 ⁄4 413 4 ⁄16 110 8x6 8x8 8 8 6 8 73⁄4 9 131⁄4 337 387 1 211⁄2 546 622 1 143⁄4 375 451 1 11 161⁄4 413 502 3 45⁄16 110 137 137 162 162 203 203 203 229 229 167 300 130 8. In.500 x 3.7 20.500 4.077 1.D.7 20.3 211.271 300 75 6x6 8x5 6.9 3 2 ⁄2 65 80 5 8 13 ⁄2 343 13 ⁄2 343 2 ⁄4 57 3x3 3 3 5 8 131⁄2 343 9 9 71⁄2 7 1 101⁄4 260 213⁄16 71 58 300 35 4 x 21⁄2 4x3 4.7 20.500 x 2.3 5 5 6 ⁄2 61⁄2 10 ⁄2 267 17 ⁄2 445 13 ⁄4 349 10 13 ⁄2 343 4 ⁄16 110 84 84 117 755 607 607 6x3 6x4 6 6 3 4 101⁄2 267 267 171⁄2 445 445 113⁄4 298 298 71⁄2 9 131⁄2 343 343 35⁄16 35⁄16 45⁄16 110 94 94 300 300 72 73 61⁄2 101⁄2 101⁄2 267 171⁄2 171⁄2 445 113⁄4 133⁄4 349 131⁄2 131⁄2 343 6x5 6. 2.750 323.7 20.6 406.9 x 73.3 141.7 20.7 20. Cylinder Working Open Area Pressure In./mm OAH In. Not for use in copper systems.D.875 114./DN(mm) O.3 219.500 141.563 168.875 x 2.271 5.7 20.500 x 2.3 219.VALVES And AccESSorIES fiG.500 x 2.9 14 14 10 12 11 11 241⁄4 241⁄4 616 201⁄2 201⁄2 521 584 584 16 19 341/4 341/4 870 914 914 36 8 695 300 382 14 x 14 14.750 14.716 1.875 3.7 20.3 173.000 16 14 12 261⁄4 Other sizes available on special request.6 x 273./mm T-O In.7 20.3 6 8 6 5 131⁄4 337 1 211⁄2 546 1 143⁄4 375 3 11 10 161⁄4 413 1 45⁄16 110 5 167 167 300 300 120 128 8.0 34.0 86.7 20.625 10.anvilintl.000 x 14. Each Lbs. -1" NPT for sizes 6 x 6 thru 16 x 14.7 20.1 10 10 10 171⁄4 438 438 1 28 28 195⁄8 498 498 1 16 16 233⁄4 603 603 1 63⁄8 63⁄8 8 8 384 384 300 300 225 230 12 x 10 12 x 12 12.750 x 12.0 33.8 32.9 101⁄2 267 1 171⁄2 445 1 113⁄4 298 3 131⁄2 343 1 35⁄16 84 5 94 300 300 72 75 5x5 5.7 20.4 x 355.563 6.0 3 2 1 5 8 131⁄2 343 1 9 9 6 7 131⁄2 343 1 21⁄4 57 1 42 48 300 300 34 34 3 x 2 ⁄2 80 x 65 80 x 80 100 x 65 100 x 80 100 x 100 125 x 100 125 x 125 150 x 80 150 x 100 150 x 125 150 x 150 200 x 125 200 x 150 200 x 200 250 x 200 250 x 250 300 x 250 300 x 300 350 x 250 350 x 300 350 x 350 400 x 350 3. 4.1 34. “CLR” Dimension indicates clearance needed for diffuser basket removal. 40 Pipe for 21⁄2" thru 10" pipe and 2" SCH.625 x 8.8 211.3 x 168.625 x 6.7 20.750 x 8.3 x 88.3 x 114.500 114.9 16.4 15.716 2.com GL-7.2 90.Use 11⁄4" SCH.477 2.484 5.0 21⁄2 65 80 80 80 100 100 100 125 125 150 150 150 150 200 200 200 250 250 300 300 350 350 350 400 21⁄2 65 50 127 127 127 127 127 127 165 165 165 165 165 165 197 197 197 229 229 254 254 279 279 279 305 305 5 203 203 203 203 203 203 8 131⁄2 343 229 229 229 229 229 229 9 178 152 178 191 178 191 229 229 254 191 229 254 279 254 279 7 131⁄2 343 21⁄4 57 310 271 310 374 310 374 607 607 48 20.750 273./mm System Pump Side Side (Grooved) (Flanged) In.3 173.7 20.875 114.3 16. 1.3 168.1 x 219./cm./mm CLR In.3 x 88.375 88.3 x 114. for ordering information.7 300 14.9 x 323.3 4 3 5 8 13 ⁄2 343 9 7 ⁄2 9 9 10 ⁄4 260 2 ⁄16 71 4x4 5x4 4 5 4 4 61⁄2 61⁄2 1 101⁄2 267 171⁄2 445 113⁄4 298 131⁄2 343 35⁄16 84 94 300 70 5.875 73.4 15.750 x 10. for certified values.9 4 21⁄2 65 80 100 100 125 80 100 125 150 125 150 200 200 250 250 300 250 300 350 350 5 8 131⁄2 343 1 131⁄2 343 1 21⁄4 57 13 48 58 300 300 36 37 4./mm C-O In.0 x 73.7 34.484 4.7 20. Wt.3 6 5 61⁄2 73⁄4 3 10 117 755 1.4 58. 106 www.500 x 3.625 x 4.9 x 273.750 12.477 4. Sq./DN(mm) C-E In.3 x 2.563 x 4.500 168.000 x 10.7 20.7 20./Kg 21⁄2 x 21⁄2 65 x 65 80 x 50 2.000 355.625 x 5.6 x 323.1 x 168.12 .625 219./mm Orifice Max.625 x 3.625 x 5.1 x 273. Sq.9 x 60. In.8 32 3x2 1 3. 3. Drain Holes: (End Cap) -3⁄4" NPT for sizes 21⁄2 x 21⁄2 thru 6 x 5. “Orifice Cylinder Open Area” is the total area of the opening in the diffuser basket after the prefilter screen has been removed.625 168.563 x 5.7 20.563 8.7 20.9 x 88.7 20.500 88.750 x 10.750 355. 40 Pipe for 12" and larger diffusers.6 14 14 12 261⁄4 667 667 39 39 23 23 21 21 36 36 9 9 817 817 300 300 467 467 16 x 14 16.8 31.3 x 114.077 1.625 273.3 x 141. 7250 FLOW OAW T-O CLR C-O OAL SIzES 21/2" X 21/2" thru 16" x 14" FIGurE 7250 SuctIon dIFFuSEr Nominal Size In.7 102.500 x 4.9 355.3 88.7 20.0 54./DN(mm) In.000 x 14.1 x 219.1 59.6 x 355. Dimensions may vary Contact an Anvil Rep./mm OAL In. Working Pressure 175 PSI (12 bar) @ 150° F (66° C) 150 PSI (10 bar) @ 250° F (121° C) Test Pressure 300 PSI (21 bar) @ 70° F (21° C) Max. 3⁄4 & 1 10 ⁄8 ⁄16 2 130 51⁄4 100 43⁄4 100 43⁄4 51⁄2 2. GASKET: Non Asbestos 7. LOCATOR: Stainless Steel-T304. PIN RETAINER: Stainless Steel-Ph 15-7 MO 14. Max. SEAT: Stainless Steel-T303. Air in the piping system is vented through the discharge valve that is normally open. COVER BOLT: Carbon Steel-Sae Grade 5 10 FLOAT ARM: Stainless Steel-T304. FLOAT: Stainless Steel-T304. ASTM A 240 6. COVER: Cast Iron ASTM A 126.anvilintl. 20 & 25 ⁄2. Ea Lbs./mm Approx. Ea Lbs./Kg 150 10 250 120 15. Wt. BODY: Cast Iron ASTM A 126./mm 1 3 Outlet Size NPT In. ASTM A 240 4./mm 1 Outlet Size NPT In. Water Pressure PSI/bar ModEL GAV-15 AutoMAtIc AIr VEnt Valve Size In./mm 1 1 1 Approx. ORIFICE BUTTON: Viton 12. The Stainless Steel float and valve mechanism involve no wearing parts.com GL-6. ASTM F 593 INLET 51/4 " OUTLET 4 3/4 " www. The valve outlet is tapped to take a safety drain line. Class B 3. The precision formed cast iron body custom fits the float and valve./mm Length In. 582 5. and no intricate function. Rising water activates the float to close the valve. ASTM A 240 11. and protectively houses their operation under the most demanding conditions. Wt./mm 1 1 1 Orifice Size In. °F/°C Inlet Size NPT In. Class B 2. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories model Gav-15 • Two Sizes Equip All Riser Systems • Spherical Float for Strength • Stainless Steel Float and Trim • Special Design Eliminates Blow-by The Air Vent (GAV) features a Stainless Steel spherical float design./mm Width In./Kg 15 20 25 ⁄2 ⁄4 250 250 250 120 120 120 15 20 25 ⁄2 ⁄4 15 15 15 ⁄2 ⁄2 ⁄2 ⁄16 ⁄16 ⁄16 2 2 2 51⁄2 51⁄2 51⁄2 3 3 3 1 1 ModEL GAV-15 AutoMAtIc AIr VEnt Type GAV-15 Max. PIVOT PIN: Stainless Steel-T303. PIPE PLUG 1⁄2": Steel 21. LEVER FRAME: Stainless Steel-T304./mm 1 Overall Height In. °F/°C Inlet Size In.VALVES & AccESSorIES Automatic Air Vents For Ultimate Performance Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.11 107 .5 material specifications 1./mm 1 3 Maximum Temp. 582 13. Simplicity of design in the GAV ensures long-lasting efficiency./mm 3 Valve Orifice In. Temp. ASTM A 240 NOTE: All specification as last revised 51/8" OUTLET 6" INLET 108 www. °F/°C Inlet Size In./mm 1 Valve Orifice In. Lbs.VALVES And AccESSorIES model Gav-30 • Two Sizes Equip All Riser Systems • Spherical Float for Strength • Stainless Steel Float and Trim • Special Design Eliminates Blow-by Automatic Air Vents for Ultimate Performance The Air Vent (GAV) features a Stainless Steel spherical float design./mm Width In. COVER: Cast Iron ASTM A 126. Each. The Stainless Steel float and valve mechanism involve no wearing parts./Kg In. Wt. PIN RETAINER: Stainless Steel-Ph 15-7 MO 14. SEAT: Stainless Steel-T303. The precision formed cast iron body custom fits the float and valve.com GL-6./mm 1 Outlet Size NPT In./mm Approx. ASTM F 879 21. Water Pressure PSI/bar ModEL GAV-30 AutoMAtIc AIr VEnt Valve Size In. ASTM A 240 6. Max. Simplicity of design in the GAV ensures long-lasting efficiency.7 250 120 ⁄2. 3⁄4 & 1 ⁄2 ⁄16 2 6 150 51⁄8 125 51⁄8 125 71⁄2 3. Each. 20 & 25 15 material specifications 1.4 15. Working Pressure 300 PSI Test Pressure 450 PSI Type GAV-30 Max. Temp./mm 1 3 Maximum Inlet Size Outlet Size Temp. BODY: Cast Iron ASTM A 126. NPT NPT °F/°C In. PIPE PLUG: Steel 17. LEVER FRAME: Stainless Steel ASTM A 240 4. ASTM F 593 34. Class B 3. Air in the piping system is vented through the discharge valve that is normally open. 582 5./mm Length In. GASKET: Non Asbestos 7. and no intricate function./mm 1 1 15 20 ⁄2 ⁄4 250 250 120 120 15 20 ⁄2 ⁄4 15 15 ⁄2 ⁄2 ⁄16 ⁄16 2 2 8 8 3 3 ModEL GAV-30 AutoMAtIc AIr VEnt Max. Rising water activates the float to close the valve./mm 1 Overall Height In.anvilintl. Class B 2. COVER BOLT: Alloy Steel ASTM A 449 Grade 5 10. PIVOT PIN: Stainless Steel-T303. The valve outlet is tapped to take a safety drain line. LOCK WASHER: Stainless Steel T304. FLOAT RETAINER: Stainless Steel T304. ORIFICE BUTTON: Viton 12./Kg 300 20. 582 13. Wt. Lbs. FLOAT ARM: Stainless Steel-T304. ASTM A 240 11.11 . and protectively houses their operation under the most demanding conditions. FLOAT: Stainless Steel-T304./mm 1 1 Approx. LOCATOR: Stainless Steel-T304./mm 1 3 Orifice Size In. 6 8.anvilintl.5 times their maximum rated working pressure and manufactured with a 4:1 safety factor.7 11⁄4 31.D. Offset is measured as displacement of the free end centerline from the fixed end centerline.375 60. af21-GG Grooved Ends Flex Connector 300 Series SS Ferrule Sch.750 273. AnvilFlex™ connectors also absorb vibration and noise found in pump installations.The maximum fixed parallel offset to which the corrugated metal hose assembly may be bent without damage.4 www.3 16 406. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories anvilflex™ flex connectors AnvilFlex™ Flexible connectors are used to prevent damage to pumps caused by piping stress.0 150 10./DN(mm) O.3 16 406. Their compact design saves valuable space.4 1 12 300 12.6 9.0 46./mm 3 Approx.4 155 10.500 88.5 12.0 11⁄4 31.0 20.0 6.6 12.500°F (816° C)./mm Pressure 70°F PSI/bar Parallel Offset * Permanent In.9 12.8 ⁄8 ⁄8 ⁄4 ⁄4 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 2.com GL-7.4 22. 40 Carbon Steel Grooved Ends AF21-GG GrXGr FLEX connEctorS Nominal Size PARALLEL VIBRATION In.5 1 6 150 6. Contact your Anvil representative for additional information.1 20 508.4 1 4 100 4.7 7 6. See page 182 for installation instructions.625 168.3 12 304.0 12 304.325 psi (91 bar) or full vacuum and operating temperatures of -400°F (-240° C) to +1. 5 125 5./mm Intermittent In.0 19.4 1 8 200 8.1 16 406.0 9.2 5 9.500 114.0 ⁄4 ⁄2 ⁄8 ⁄8 ⁄2 ⁄8 ⁄2 4.7 5 6.9 1 6.7 6.8 275 19.875 73. No further motion is to be imposed other than normal vibration.4 165 11. Intermittent Offset is motion that occurs on a regular or irregular cyclic basis.8 3 3.2 15.4 1 10 250 10. In.1 12. They are designed to be pressure tested 1. Ea.3 38. Lbs.5 1.0 5.VALVES & AccESSorIES Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.4 15.6 270 18.625 219.0 3.563 141. NOTE: AnvilFlex™ flex connectors are manufactured with a 4:1 safety factor.1 PARALLEL OFFSET MOTION: Motion that occurs when one end of the hose assembly is deflected in a plane perpendicular to the longitudinal axis with the ends remaining parallel.8 300 20. It is normally the result of thermal expansion and contraction or other noncontinuous actions./kN 2 2.4 3 Permanent Offset .5 3 21⁄2 65 2.5 1 3 80 3.1 1 6.4 225 15. AnvilFlex™ connectors are easily installed and reduce the possibility of pump failure. # AF0390232007 AF0390232106 AF0390232031 AF0390232114 AF0390232122 AF0390232130 AF0390232148 AF0390232155 AF0390232163 A In.12 109 .9 1 6. AnvilFlex™ connectors are manufactured with 321 stainless steel annular corrugated close pitch metal flexible hose.0 17.7 20.0 145 10. material specifications HOSE: 300 Series Stainless Steel BRAID: Stainless Steel Type 304 ENDS: Schedule 40 Carbon Steel Grooved-Ends A ± . Working pressure of standard hose and braid up to 1. Other stainless steel and corrosion resistant alloys are available.3 14 355.750 323.9 20 508.9 12 304./mm Model or 10 dig.125 300 Series SS Annular Corrugated Hose 304 SS Braid motion classifications AnvilFlex™ flex connectors are braided pump connectors capable of handling the following movements: fiG.4 14.5 1. Wt.5 2. MOTION FREQUENCY: 50 9.8 450 31. 8 275 19.9 1 6.7 1 25.750 323.4 * See Motion Classification on previous page for additional information. af21-Gf Grooved x Class 150 Flanged Flex Connectors Nominal Size A ± .625 168.4 23.7 6.5 25.6 12. # AF0390232387 AF0390232395 AF0390232403 AF0390232429 AF0390232437 AF0390232445 AF0390232452 AF0390232460 AF0390232478 A In.625 219.4 3 5 125 5.0 12.0 12 304.8 145 10.VALVES And AccESSorIES fiG.3 8.0 5.4 1 12 300 12.6 300 20.7 10./DN(mm) AF21-GF GrXFL FLEX connEctorS O.5 1 6 150 6.3 19.7 54. Ea./kN 2 50 2.625 168.6 ⁄8 ⁄8 ⁄4 ⁄8 ⁄8 ⁄2 14.4 1 4 100 4./mm Intermittent In.3 14 355.7 6.1 15 381.6 145 10./mm Pressure 70°F PSI/bar Parallel Offset Permanent In.6 450 31.1 15.9 5 21⁄2 65 2.9 15.5 1 8 200 8.0 15.4 3 300 Series SS Ferrule 5 Plate Steel Flange 150# Drilling Flat Face 125 5.0 9 228.750 273.9 7 6. fiG.0 47./mm Intermittent In.4 1 10 250 10.6 275 19./mm Model or 10 dig.3 22.com GL-6.6 15.2 3 9.4 30./mm Model or 10 dig.500 88.6 ⁄8 ⁄8 ⁄4 ⁄4 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 10.3 75.7 3 6.5 12. Wt.0 6./DN(mm) AF21-FF FLXFL FLEX connEctorS O.500 114.9 17 431.0 6.5 3 6 150 6.9 1 3 Plate Steel Flange 150# Drilling Flat Face 80 3.875 73. In.1 5 9.125 304 SS Braid 2 50 2. af21-ff Class 150 Flanged x Class 150 Flanged Flex Connectors Nominal Size In.1 16 406. 110 www.0 155 10.9 14 355./mm Pressure 70°F PSI/bar Parallel Offset Permanent In.6 270 18.4 4.3 11 279.500 88.4 1 10 250 10./mm 5 Approx.3 11 279.0 105. Lbs.0 4.4 9.0 ⁄8 ⁄2 ⁄4 ⁄8 ⁄2 ⁄2 ⁄2 14.0 11⁄8 28.9 12 304.7 12.4 150 10.0 11.8 155 10.9 5 6. 40 Carbon Steel Grooved Ends 4 100 4.125 300 Series SS Annular Corrugated Hose 304 SS Braid In.8 300 20.9 1 6.4 * See Motion Classification on previous page for additional information.7 1 6.4 1 12 300 12.anvilintl.8 19.0 13.3 12 304.0 34.6 5 10.750 273.5 3 21⁄2 65 2. In.2 3.500 114. # AF0390232197 AF0390232213 AF0390232171 AF0390232189 AF0390232247 AF0390232254 AF0390232262 AF0390232270 AF0390232288 A In./kN 300 Series SS Annular Corrugated Hose A ± .0 11⁄8 28.6 225 15.0 17⁄8 47.D. Wt.7 39.4 225 15.9 9 228.750 323.9 1 6.4 15.4 8.7 1 300 Series SS Ferrule Sch.3 12 304.6 18.4 1 8 200 8.6 19. Ea.875 73.5 18.4 165 11.8 450 31.1 13 330.3 40 18.7 12.625 219.3 9 228.6 165 11.1 5 9.3 15.563 141.7 15⁄8 41.4 15.0 8.8 270 18./mm 3 Approx.2 150 10.5 9.5 1 3 80 3.4 5 12.563 141.6 12.3 9 228. Lbs.D.375 60.7 1 6.6 ⁄8 ⁄8 ⁄2 ⁄4 ⁄8 ⁄8 ⁄4 ⁄4 ⁄4 7.0 24.375 60.3 14 355.0 50 22.11 .1 12 304.5 3. 7 18.1 20 508.625 168.3 11.3 4.5 3 Factor S.1 19.0 5.5 3 6 150 3.2 225 15.4 1 600 315.4 28.5 7./kN 2 11⁄2 40 50 1.D.6 200 250 8 10 250 8.660 42. Multiply pressure shown at 70°F. 1.5 1 4 100 3.8 6.500 88.4 1 400 204.5 15.5 19.6 15.1 5 9.7 1 6.anvilintl.5 3 4 6 150 4.125 300 Series SS Annular Corrugated Hose 304 SS Braid 300 Series SS Ferrule Plate Steel Flange 150# Drilling Flat Face Bolt Holes Straddle Centerline AF21-rFF FLXFL rEducInG FLEX connEctorS Nominal Size Small Flange In.1 ⁄8 ⁄8 ⁄8 ⁄8 ⁄4 ⁄8 ⁄4 ⁄8 ⁄8 ⁄4 ⁄8 ⁄8 ⁄8 ⁄8 ⁄4 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 6.8 19.2 5.625 219.625 168.375 60.500 114.875 73.0 ⁄4 ⁄2 ⁄4 ⁄2 ⁄4 ⁄4 ⁄2 ⁄4 ⁄4 ⁄4 ⁄4 ⁄8 ⁄4 ⁄8 ⁄2 ⁄2 ⁄2 ⁄2 10.7 12.0 15.1 3 9. times correction factor of require temperature.com GL-6.2 225 15.9 4.D.4 3 200 93.5 3 2 3 80 2.0 14 355.6 165 11.1 10.4 15.3 19 482.563 141.7 11⁄4 31.3 6.6 300 20.1 5 9.5 1 4 21⁄2 65 100 2.500 114.7 11⁄4 31.9 5.0 5.8 145 10.3 15 381. Ea.9 571 For safe working pressure above 70°F (21.660 42.750 323.0 125.6° c) Temperature °F / °C 80 3 5 125 3.500 114.3 19 482.3 18 457. In.1 1 9.0 150 10.4 1 10 12 300 10.7 9.9 22 558.7 1 6.3 19 482.7 3.7 41.3 6 125 5.3 19 482.3 83.VALVES & AccESSorIES Class 150 Flanged x Class 150 Flanged Reducing Flex Connectors Sch.1 3 9.0 11⁄2 38.0 270 18.500 88.3 8.5 1 4 100 2.7 70 21.4 3 3 80 2.5 21.0 6.5 1 8 200 5.1 3.1 3 9.1 9.8 5 150 19.500 114.88 0.5 1 8 200 4.625 168.750 273.7 18.7 3 6.0 3. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.9 6 200 12.3 2.3 6.9 19.0 12.1 37.6 19.563 141.0 155 10.4 17.9 14 355.4 12.3 18 457.7 8.9 1 6.375 60.1 1 9.7 3 6.3 3.1 20 508.9 3.0 155 10.5 3 6 150 2.7 6.6 450 31.0 11./mm Length In.4 * See Motion Classification on page 109 for additional information. In.0 270 18.625 168.3 95.1 12. 12.S.7 38.500 88.875 73.500 114.6 275 19.0 150 10.6 300 20.750 273.0 43.4 31.1 4.1 20 508.3 18 457.7 40.00 0./mm Large O. 40 Carbon Steel Concentric Reducer A ± ./DN(mm) Small O.625 219.625 168.625 168.4 1 500 260.6 19.3 5.9 8.500 114.1 20 508.4 25.0 14.3 14 355.4 26.1 19.4 3 For tEMP ABoVE 70°F (21.0 12.2 225 15.3 8.2 2.8 3 8.5 3 21⁄2 65 50 2.1 1 9.6 14.0 14 355.563 141.6 12.875 73.9 3 6.0 4.8 19.11 111 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.625 219.1 12.2 2.7 3 6.9 14 355.6 165 11.6 165 11.7 1 6.563 141.5 19.563 141.0 155 10.375 60.3 15 381./DN(mm) Large Flange In.750 273.1 11.625 219. Working pressures shown for the hose and braid are based on an operating temperature of 70° F (21° C) with a 4:1 safety factor.875 73.6 165 11.9 6./mm Intermittent In. www.9 3 21⁄2 65 1.500 88. af21-rff .6 9.500 88.1 3 9.78 0.83 0.4 8 150 6.0 10 250 6.94 0.5 18.875 73.7 6.4 3 5 125 2.0 270 18.7 12. Lbs.1 300 148.1 20 508.6 275 19.74 5 125 100 4./mm Pressure 70°F PSI/bar Parallel Offset Permanent In.3 15 381.3 8./mm 5 Approx.875 73.375 60. Wt.1° C).3 10. 7 18.0 14 355.7 3 6.6 9. Wt.4 31.5 1 400 204.1 23 584.1 5 9.1 3.9 1 6.625 168.4 8 200 5.3 3.8 3 8./DN(mm) Small O.0 155 10.94 0.1 20 508.9 5.6 165 11.500 114.88 0.5 3 6 150 2.3 18 457.0 155 10.625 168.9 3.7 6.7 18.500 88.6 275 19.4 3 3 5 125 3.2 2.3 14 355. In.8 19.625 168. Working pressures shown for the hose and braid are based on an operating temperature of 70° F (21° C) with a 4:1 safety factor.com GL-6.1 4 6 150 4.6 165 11.6 300 20.8 19.7 38.6 12.1 1 9.6 275 19.1 19.5 15.375 60.500 114.3 6.9 14 355.5 3 70 21.563 141.4 3 5 125 2.5 19.5 1 4 21⁄2 65 100 2. 1. 40 Carbon Steel Concentric Reducer A ± .S.83 0.5 3 Factor S.3 6.7 12.2 150 10.3 8.4 1 600 315.1 4.6 14.1 5 9.0 ⁄4 ⁄2 ⁄4 ⁄2 ⁄4 ⁄4 ⁄2 ⁄4 ⁄4 ⁄4 ⁄4 ⁄8 ⁄4 ⁄8 ⁄2 ⁄2 ⁄2 10.9 3 6./mm Large O.D.625 168.0 12.9 25 635.5 3 21⁄2 65 50 2.1 10.3 14 355.875 73.5 19. Lbs.3 19 482. times correction factor of required temperature.7 1 6.3 8 200 4. 112 www.0 For tEMP ABoVE 70°F (21.500 88.3 4.750 273.1 3 9.7 9.0 38.2 2.6 19.3 84.500 88.625 168.9 6.9 4./kN 2 11⁄2 40 50 1. Multiply pressure shown at 70°F.3 19 482.2 225 15. Ea. 10 12 300 10.0 6.0 11.563 141./DN(mm) Large Groove & Hose In.5 21.563 141.625 219.7 3 6.500 114.7 11⁄4 31.1 3 9.7 40.375 60.5 18.5 3 5 125 100 4.5 3 2 3 80 2.4 3 300 148.00 0.5 1 200 93.3 8.1 20 508.3 19 482.6 300 20.7 3 6.563 141.875 73.3 14 355./mm Intermittent In.6 450 31./mm Length In.6 15.1 1 9.750 323.9 14 355.0 11⁄2 38.375 60.875 73.500 88.1 20 508.0 3.3 18 457.1 ⁄8 ⁄8 ⁄8 ⁄8 ⁄4 ⁄8 ⁄4 ⁄8 ⁄8 ⁄4 ⁄8 ⁄8 ⁄8 ⁄8 ⁄4 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 6.7 3.750 273.625 219.3 5.4 25.1 1 9.3 2.4 15.0 15.8 6 5 150 5.4 26.4 1 For safe working pressure above 70°F (21.9 3 21⁄2 65 1.9 8.660 42.7 6.660 42.VALVES And AccESSorIES fiG.3 15 381.3 11.2 5.6 270 18.4 1 500 260.1 3 9.0 5.5 1 4 100 2.2 225 15.7 8.74 125 6 150 3.500 88.0 150 200 250 6 8 8 200 6.2 225 15.6 10 250 8.anvilintl.563 141.6 270 18.4 17.3 12.1° C).375 60.0 155 10.875 73./mm Pressure 70°F PSI/bar Parallel Offset Permanent In.875 73.875 73.625 219.1 11.1 9.4 * See Motion Classification on page 109 for additional information.500 114.625 219.6° c) Temperature °F / °C 100 80 12.500 114.0 14 355. In.5 1 4 3.1 3 9.3 8.7 19.3 18 457.4 3 3 80 2.0 5.125 300 Series SS Annular Corrugated Hose 304 SS Braid Plate Steel Flange 150# Drilling Flat Face 300 Series SS Ferrule Sch.9 12.11 .D.6 165 11./mm 5 Approx.0 4. af21-rGf Grooved x Class 150 Flanged Reducing Flex Connectors Sch.500 114.78 0.7 41.7 1 6.3 19 482.1 12.5 7.0 46.6 19. 40 Carbon Steel Grooved Ends AF21-rGF GrXFL rEducInG FLEX connEctorS Nominal Size Small Flange In.9 19.0 102.1 12.8 6.0 270 18.0 145 10.4 12.6 165 11.4 28.1 19.7 11⁄4 31.0 14. notES www.anvilintl.com 113 . Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids.12 .anvilintl.9 bar). alkalies solutions. Air with oil vapors and vegetable and mineral oils. 7004 can be used with EG fittings as a commercial joint only. will benefit from the increased pressure capability. matERIaL SPECIFICatIONS ANSI BOLTS & HEAVY HEX NUTS: Heat treated. including auto and truck washes. Grade “L” Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry.com GL-7. STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are also available. petroleum oils. END LOAD. hydraulic fluids. See technical data section for design factors. The Fig. oil-free air and many chemical services.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. 7004 coupling permits working pressure ratings up to 1000 psi (68. or J995 Grade 2. PIPE END SEPARATION & DEFLECTION FROM CENTER LINE: Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. Bolts and nuts are provided zinc electroplated as standard. diluted acids. COATINGS: Rust inhibiting paint – Color: Orange (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. GASKET TYPE: Standard C Style Flush Gap (2" . halogenated hydrocarbons and lubricants. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. HOUSING: Ductile Iron conforming to ASTM A 536. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) NSF 61 Certified -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service. Fig. NOTE: Fig.high pressure systems HIGH PRESSURE COUPLINGS FIG. NOT FOR USE IN PETROLEUM APPLICATIONS. 7004 Coupling The Gruvlok Fig. The Fig.12") LUBRICATION: Standard Gruvlok Gruvlok XtremeTM(Do Not use with Grade “L”) 114 www. METRIC BOLTS & HEAVY HEX NUTS: Heat treated. WORKING PRESSURE. 7004 is designed to provide the versatility of a grooved joint while providing a rigid pipe joint. Working Pressure & End Load values are based on grooved standard wall pipe. Grade 65-45-12. Systems used for high pressure. 7004 coupling is an ideal choice for higher pressure applications such as elevator services. Contact an Anvil Representative for more information. hot air and some high temperature chemical services. This coupling is also suited for lower pressure systems which experience pressure pulses. 7004 provides a rigid joint and does not allow for expansion or contraction. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications. Hex nuts are zinc electroplated followed by a yellow chromate dip.8. NOT FOR USE IN HOT WATER OR HOT AIR. 4 M22 x 150 7 6 150 6./DN(mm) O./Kg 2 50 2. Wk.2 102. Wt.875 73.7 0 -1⁄32 0 ./mm Qty.2 46.1 800 55.38 83⁄4 222 121⁄8 308 21⁄4 57 15.8 0 -3⁄32 0 .D.HIGH PrESSurE SYStEMS Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.6 2.com GL-6.0 6.0.2.9 800 55.9 1000 68./mm Coupling Bolts Z In.2.2.625 219.9 For additional details.5 7. End Load Lbs.563 141.11 115 ./mm Approx. Ea.500 88.3 1000 68. Pressure PSI/bar Max.3 1000 68.0 1000 68.9 4.0.472 153.79 47⁄8 124 71⁄2 191 17⁄8 48 5.2 2.6 11.38 131⁄2 343 17 432 25⁄8 67 1 x 61⁄2 – 32.9 15.1 800 55./kN Range of Pipe End Separation In.2.8 0 -1⁄32 0 .7 12 300 12.2.306 108.6 10 250 10. In. Lbs.375 60. see coupling data chart notes from page 17.3 1000 68./mm Coupling Dimensions X In.9 6.79 41⁄4 108 67⁄8 175 17⁄8 48 5 ⁄8 x 31⁄2 ⁄8 x 31⁄2 ⁄4 x 41⁄2 ⁄8 x 51⁄2 ⁄8 x 51⁄2 4.0 M22 x 150 8 200 8.38 71⁄2 191 11 279 21⁄4 57 14.anvilintl.3 1000 68./mm Max.9 19.8 21⁄2 65 2. See Installation & Assembly directions on page 169.3 0 -3⁄32 0 .9 0 -1⁄32 0 .904 70.0 0 -3⁄32 0 . 7004 Y Z X Fig.0.9 34.6 3.38 111⁄8 283 147⁄8 378 25⁄8 67 1 x 51⁄2 – 25.9 1.741 207.38 61⁄4 159 91⁄2 241 21⁄4 57 8.9 24.750 273./mm Y In.4 0 -3⁄32 0 .4 M16 x 85 3 4 100 4.610 323.79 35⁄8 92 61⁄4 159 17⁄8 48 ⁄8 x 23⁄4 – 3.9 0 -3⁄32 0 . 2 2 2 2 2 2 2 2 2 5 Size In.1 0 -3⁄32 0 .3 14.430 19.9 9.2 72.38 157⁄8 403 191⁄4 489 25⁄8 67 1 x 61⁄2 – 43.9 M20 x 110 7 5 125 5.1 M16 x 85 5 3 80 3.621 42. 7004 with standard gasket FIGurE 7004 couPLInG Nominal Size In.2. Not for use in copper systems.750 323. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.625 168. www.500 114.492 28.141 454. 12 . zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8. METRIC BOLTS & HEAVY HEX NUTS: Heat treated. Air with oil vapors and vegetable and mineral oils. Bolts and nuts are provided zinc electroplated as standard. WORKING PRESSURE. Hex nuts are zinc electroplated followed by a yellow chromate dip. END LOAD.anvilintl.000 psi and heavy hex nuts of carbon steel conforming to ASTM A563 Grade A or Grade B. Grade 65-45-12.8. Working Pressure and End Load values are based on “EG” cut grooved extra heavy steel pipe. Fig. 7004 Coupling with EG® Gasket permits working pressure ratings up to 2500 psi (172. STAINLESS STEEL BOLTS & NUTS: Stainless steel bolts and nuts are also available. oval neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110.high pressure systems FIG. NOT FOR USE IN HOT WATER OR HOT AIR. COATINGS: Rust inhibiting paint – Color: Orange (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. PIPE END SEPARATION & DEFLECTION FROM CENTER LINE Based on standard wall steel pipe with cut or roll grooves in accordance with Gruvlok specifications. 7004 provides a rigid joint and does not allow for expansion or contraction. Beveled end pipe should not be used with “EG” gaskets. HOUSING: Ductile Iron conforming to ASTM A 536. Contact an Anvil Representative for more information. GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “T” Nitrile (Orange color code) EG Gasket -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications.com GL-7. GASKET TYPE: “EG” Style LUBRICATION: Standard Gruvlok Gruvlok XtremeTM(Do Not use with Grade “L”) 116 www. See technical data section for design factors. 7004 Coupling with EG® Gasket uses the specially designed “End Guard” gasket for use with “EG” grooved pipe. 7004 with EG® Gasket Coupling The Gruvlok Fig. or J995 Grade 2. The “EG” gasket has a center rib which extends between the pipes in order to provide pipe end protection. matErIal spEcIFIcatIons ANSI BOLTS & HEAVY HEX NUTS: Heat treated.4 bar). which makes it ideally suited for internally lined or coated pipe applications. The Fig. Ea.750 323.639 389.84 0 -3⁄32 0 .4 24.9 For additional details. Pressure PSI/bar Max.595 709.2.3 2500 172.0 4.7 12 300 12.38 131⁄2 343 17 432 25⁄8 67 1 x 61⁄2 – 32./Kg 2 50 2.3 14. See Installation & Assembly directions on page 170./mm Y In.761 176.38 157⁄8 403 191⁄4 489 25⁄8 67 1 x 61⁄2 – 43.38 83⁄4 222 121⁄8 308 21⁄4 57 15./mm Approx.625 219.2.1 1250 86.9 2500 172.0 2500 172. Wk. In.0 M22 x 150 8 200 8.9 21⁄2 65 2. End Load Lbs.9 1250 86.27 0 -1⁄32 0 . 7004 with eG® Gasket Y Z X Fig.79 35⁄8 92 61⁄4 159 17⁄8 48 ⁄8 x 23⁄4 – 4.HIGH PrESSurE SYStEMS Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.6 11.3 2500 172.500 88.0.2.750 273.19 0 -1⁄32 0 .86 0 -3⁄32 0 . Wt.anvilintl.053 106.4 11.79 47⁄8 124 71⁄2 191 17⁄8 48 5./DN(mm) O.66 0 -3⁄32 0 .D. see coupling data chart notes on page 17. 7004 with “EG” gasket FIGurE 7004 couPLInG WItH EG GASKEt Nominal Size In. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.230 72./kN Range of Pipe End Separation In.9 19.com GL-6.38 111⁄8 283 147⁄8 378 25⁄8 67 1 x 51⁄2 – 25.5 M16 x 85 3 4 100 4.075 49.6 10 250 10.11 117 .92 0 -3⁄32 0 .0.453 504.1 1500 103. www.5 7.9 68.38 61⁄4 159 91⁄2 241 21⁄4 57 9.2./mm Qty.2 113.0. Not for use in copper systems.3 2000 137.1 M20 x 110 7 6 150 6. Lbs.500 114.625 168.1 2.2.5 2.4 39.375 60.4 87.4 16. 2 2 2 2 2 2 2 2 5 Size In.3 M16 x 85 5 3 80 3./mm Max.79 41⁄4 108 67⁄8 175 17⁄8 48 5 ⁄8 x 31⁄2 ⁄8 x 31⁄2 ⁄4 x 41⁄2 ⁄8 x 51⁄2 5.943 306.875 73./mm Coupling Bolts Z In./mm Coupling Dimensions X In.2 159.67 0 -3⁄32 0 .1 1.99 0 -1⁄32 0 . 315 33.D. In. FIttInG SIZE Nominal Size In. COATINGS: Rust inhibiting paint – Color: Orange (standard) Hot Dipped Zinc Galvanized (optional) Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative.500 88.625 168. In.3 141.3 3 80 3. 118 www.500 114./mm Center To-End In.12 . Lbs./Kg O.0 2.High Pressure 90° LR Elbow O.1 * * * * 10 250 10.High Pressure 45° LR Elbow O. Wt.8 21⁄2 65 2./DN(mm) FIGurE 7051 EG./mm 25 1 1.3 73.3 168.HIGH PrESSurE SYStEMS hiGh pressure fittinGs Gruvlok End Guard fittings are fabricated from extra heavy (XS) materials.3 61⁄2 165 27.4 6 150 6.0 33⁄4 95 4. In. End Guard fittings should only be used with Series 7004 Couplings and EG Gasket.3 2 51 1.625 8. HIGH PrESSurE 90° Lr ELBoW Nominal Size In./mm Center To-End In.D.7 42.500 114.9 41⁄4 108 6. fiG.1 11⁄2 2 5.875 73. Ea.5 1. 7051 eG .9 11⁄4 32 40 50 1.0 80 100 140 150 200 3 4 5 6 8 3.875 4./mm Nominal Size In.0 * * * * 12 12.1 2 50 2.9 1.7 3 80 3.3 5 127 11. Ea. O.4 48.D.5 8 200 8.0 21⁄4 57 2./mm Approx./Kg 2 50 2.2 1.9 21⁄2 65 2. Gruvlok EG fittings conform to NACE STD-RP-04-72 (Contact an Anvil Representative with specific service details).5 7./DN(mm) material specifications ELBOWS: Extra strong forged steel fittings conforming to ASTM A 234 with welded tangents of schedule 80 steel pipe conforming to ASTM A 106. These fittings may be used for high pressure systems and where lined or coated fittings are required. Wt. The groove conforms to Gruvlok End Guard cut grooving specification.625 219.3 31⁄4 83 2.3 31⁄2 89 16.500 88.625 168.375 2.660 1.9 * * Contact an Anvil Representative for more information.D.875 73.375 60./DN(mm) O.4 6 150 6.3 219.D.0 4 100 4.3 2.900 2.2 12.com GL-7.375 60.8 0./DN(mm) O.0 4 100 4.563 6.500 88.750 273.3 60.anvilintl.D./mm Approx.9 21⁄2 64 4. HIGH PrESSurE 45° Lr ELBoW Nominal Size In.625 21⁄2 65 fiG.0 5.5 3.500 114. C to E C to E FIGurE 7050 EG.3 3 76 7.750 * * * 300 323. TEES & CROSSES: Segment welded schedule 80 steel pipe conforming to ASTM A 106. 7050 eG . Lbs. In. 500 6.D. 7662 eG .1 1. 7060 eG .3 114.8 11./Kg 2 ⁄2 1 50 65 80 2 2.9 8.625 168.High Pressure Tee O.D.375 2.3 31⁄4 3 ⁄4 3 83 95 3.D.High Pressure Cross C to E O. FIG./mm Center To-End In.5 7.9 73.3 31⁄4 3 ⁄4 3 83 95 3.5 17. 7068 eG .6 1.3 46./DN(mm) FIG.D.1 9./mm Center To-End In. 7068 EG .375 2.9 73.3 165 127 61⁄2 5 4./mm Approx./Kg O.625 168.0 60.3 88.3 114.9 6./Kg 2 ⁄2 1 50 65 80 2 2.3 60./mm Center To-End In.3 15.875 3.3 1.HIGH PrESSurE HEAdEr tEE Nominal Size In./DN(mm) O. FIGurE 7060 EG . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories hiGh pressure fittinGs fiG.12 119 .2 4. Wt. Lbs. Ea.2 3.HIGH PrESSurE tEE Nominal Size In.500 6.com GL-7. Wt.D.3 5.D. Lbs.500 4.High Pressure Header Tee O.9 3.2 3 4 6 108 127 165 41⁄4 5 100 150 61⁄2 fiG.375 2.6 2. C to E C to E C to E C to E fiG./mm Approx.500 4. Wt./mm Approx.0 20.8 3 4 6 108 127 165 41⁄4 5 100 150 61⁄2 www.8 5.5 19. In.3 88./DN(mm) O. Lbs.anvilintl.HIGH PrESSurE croSS Nominal Size In.2 2.0 60.HIGH PrESSurE SYStEMS Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.875 3. In. Ea. In.375 60. Ea.9 38. 7662 EG .5 50 50 2 2 2. 11 . especially in a retrofit installation. • Provides rigidity • Easily roll grooved • Proven joint reliability • Accepted and approved. Essentially you save time and enjoy a very reliable system that is both versatile and economical.ctS coPPEr SYStEM Gruvlok® cts copper system The Gruvlok® CTS Copper System offers an installer of large diameter copper tubing an alternative to the conventional soldering and brazing.anvilintl. Temperature and weather conditions are no longer a factor when planning installations. benefits • Fast and easy to assemble. • Economical and reliable 120 www. • No flame. retrofit or expansion. no sweat • Each joint has a union. There is no sweating or brazing as this system requires only a wrench for assembly on grooved end pipe. The ease of assembly is a great benefit in new construction and ease of disassembly is ideal for renovation. This new grooved copper system is faster and easier to install. Safety is a factor as there is no fire hazard.com GL-6. The copper system is “flame-free”. /mm Max Wk. Grade 65-45-12 COATINGS: Rust inhibiting enamel paint — Color: Copper For other coating requirements contact your Anvil Representative. NOT FOR USE IN PETROLEUM APPLICATIONS.0.40 1.2.25 1./mm Approx.32 1 ⁄2 x 3 5.8 130.08 0 .82 27.00 76 89 5. Pressure PSI/bar Max End Load Lbs.125 8.4 0 .4 0 .15 0 .4 300 300 300 300 300 300 1623 2300 10.0.81 1.7 20. NSF 61 Certified for cold +86˚F (+30˚C) and hot +180˚F (+82˚C) potable water service.125 54.20 12. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. ANSI BOLTS AND HEAVY HEX NUTS: Heat treated carbon steel oval neck bolts conforming to the physical properties of ASTM A 183 with a minimum tensile strength of 110.4 0 . oil-free air and many chemical services.53 0.7 20.20 9.0 3. www.13 0 . contact your Anvil Representative.18 106 132 157 183 237 5.2.2.2.73 7.13 0 .0./Kg 2 21⁄2 3 4 5 6 8 2.0 66.7 20. material specifications HOUSING: Ductile iron conforming to ASTM A-536. Y Z X FIGurE 6400 rIGId couPLInG Nominal Size In. Gasket has service temperature range of -40˚F to +250˚F.69 0.7 300 1063 4.2. diluted acids.14 2.80 2.80 1.27 4. Ea.78 2.67 0 .6 206.28 7.68 43 2 2 2 2 2 2 2 3 ⁄8 x 2 ⁄4 1 1.70 1.38 3. NSF 61 Certified for cold +86˚F (+30˚C) and hot +180˚F (+82˚C) potable water service.30 69.anvilintl.000 PSI.125 4.20 6.13 6.125 104.7 79.50 9. GASKETS: Grade “EP” EPDM Flush Gap Gasket (Green and Red Color Code) Service Temperature Range: -40°F to +250°F(-40°C to +121°C) Recommended for water service.0 0 .51 39.125 6.48 2. Bolts and nuts are provided zinc electroplated as standard.ctS coPPEr SYStEM Rigid Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.68 43 43 43 46 46 51 3 ⁄8 x 21⁄4 1 1. Wt.2.7 20.76 3.0. alkaline solutions.4 3. Lbs./mm Coupling Bolts Z Qty.12 121 .7 20.20 7./mm Coupling Dimensions X Y In./kN Range of Pipe End Separation In.125 5 ⁄8 x 31⁄4 ⁄8 x 3 ⁄4 1 5 5 ⁄8 x 31⁄4 Pressure ratings and end loads are based on use with ASTM B88 Type K or L tubing. Size In. Fast and easy swing-over installation of the rugged lightweight housing produces a secure rigid pipe joint.13 0 .08 0 .68 1.0. For pressure ratings on Type M and DWV.50 4. Copper Tube Diameter In.24 7.00 127 1.71 5. 6400 The Figure 6400 Rigid Coupling is specially designed to provide a rigid pipe connection to meet the specific demands of copper tubing installation size 2"-8".2 155.10 10.50 140 159 191 231 259 315 1.0.com GL-7.4 20.48 2. Available with Grade “EP” Copper EPDM flush gap style gasket.08 0 .22 0 . See Installation & Assembly directions on page 159.23 17.625 3.00 ⁄2 x 3 4007 6186 8835 15547 5.0.7 20.2.0 0 . 12 21.9%. 6051 Fig.50 0.20 81 2.15 1.2 155.25 108 151 176 197 5.84 21.20 3.7 79.4 3.00 51 51 51 51 70 80 0.66 4./mm Wt.15 5. 6050 90˚ Elbow C to E In.00 2.94 7.52 0. 6050 fiG.82 1.0 66.13 – – 0.04 9.63 1.69 68 1.19 3.94 7. 6074 Cap Wt.15 1.59 3.36 0.81 2. Fitting pressure ratings match the ratings of the Figure 6400 Coupling. Ea.79 6.75 122 www.00 6.63 4.85 3. tEES & cAPS Nominal Size In.07 6./mm C to E In.8 130. 6060 Tee Wt.125 8.12 .38 5.25 3.00 2.31 3.82 9.00 21./mm E to E In.125 5.anvilintl.125 104.85 1.31 2.07 1.625 3.94 6. Lbs.91 74 84 97 0.88 4.77 12.6 206. Lbs. Lbs.23 0.37 3.66 1.52 89 2.4 2. C to E C to E C to E E to E fiG.25 108 0. Ea.16 0./kg dIMEnSIonS/WEIGHtS — ELBoWS.45 0. The fittings are constructed to ASTM B75 UNS C12200 with a minimum copper content of 99. 6074 Fig.52 9.28 2.00 2.81 2.75 0.31 0.81 2. 6060 Fig.75 3.ctS coPPEr SYStEM cts copper fittinGs CTS Copper Fittings are produced with groove and cup ends in a variety of fitting configurations.com GL-7.75 5.81 2. Copper Tube Diameter In. 6051 45˚ Elbow Fig. Ea./kg fiG.62 5./mm Wt.94 11.53 2.125 4.125 6.19 56 59 66 81 83 92 0.89 2. Lbs.22 2.89 0.125 54.94 6.16 13.75 121 151 176 197 1./kg 2 2 ⁄2 1 2.34 0.36 1./mm fiG.38 0./kg C to E In.40 3.89 2.52 0.61 0.68 – – 3 4 5 6 8 1.81 4.99 4.69 1. Ea. 16 4.24 4.79 1.00 76 82 88 93 – 0.45 8./kg C to ØE Cup Length In.27 2.33 2.43 2.75 19 23 25 28 19 23 25 28 0.92 2.63 3.97 1.65 1.57 2.57 0.13 5.42 10.71 0.47 3./mm In.94 100 106 95 4. 6064 3.89 3.20 2.28 83 – – – – – – – 3.00 – – – 0.88 – – 21⁄2 x 21⁄2 x 3⁄4 2 ⁄2 x 2 ⁄2 x 1 1 1 21⁄2 x 21⁄2 x 11⁄4 2 ⁄2 x 2 ⁄2 x 1 ⁄2 1 1 1 C to E 21⁄2 x 21⁄2 x 2 3 x 3 x ⁄4 3 – – – – – – – – – – – – – – – 2./mm Wt.69 4.38 86 89 – – – 2./kg 2 x 2 x 3⁄4 2x2x1 2 x 2 x 11⁄4 2 x 2 x 1 ⁄2 1 – – – – – – – – – – – – – – – – – – – – – – – – – – – 2.60 66 71 73 76 0.38 3. 6061 C to E 3x3x2 3 x 3 x 21⁄2 4 x 4 x ⁄4 3 3.93 5.93 0.97 1.91 0.63 1.85 – – – – – – – 3.56 4.25 1. 6061 Groove x Groove x Groove C to E In.25 – – – – – 3./mm C to ØE In.06 10.14 2./mm Wt Ea.47 – – – – – – – – – – Cup Length C to ØE 4 x 4 x 11⁄2 4x4x2 4 x 4 x 21⁄2 4x4x3 5x5x3 5x5x4 6 x 6 x 21⁄2 6x6x3 6x6x4 6x6x5 fiG.36 5.95 75 79 83 85 – 3.97 1.40 0.57 0.88 0.70 – – 2. 6064 Groove x Groove x Cup C to E In.75 0.18 2.55 2.20 56 59 63 65 58 61 64 69 1.03 1.04 2.25 3.40 2.68 – – 0.11 123 .09 – – – 2.09 – – 1.09 – – – – – – – – – – 3.54 2.13 9.19 106 119 4./mm Nominal Size Fig.13 105 103 106 118 116 130 132 130 132 – – – 5.88 0.38 1.ctS coPPEr SYStEM Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.54 1.91 0.77 3.35 – – – – – – – – – – 3.69 www.45 62 65 67 72 2.25 108 92 94 3.35 2.85 – – – 2.10 3.85 0.67 3.75 4.19 5.33 2. Lbs.97 1.63 2.com GL-6.94 4.40 2.06 4.28 2.38 86 – – – – – – – 2.13 2.75 19 23 25 28 – 3.66 93 – – – 4.73 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 4.27 4.56 5.63 0.13 5.15 2.16 – – – – – – 2.25 1.69 4.91 0.91 0.86 12.63 4.19 3.79 2.98 50 56 60 58 55 61 65 68 0.97 1.25 – – – C to ØE 3 x 3 x 1 ⁄4 1 3 x 3 x 11⁄2 fiG.anvilintl.43 2.02 3x3x1 – – – 3.90 1.51 0. Ea Lbs.65 – – – – – – – – – – 0.56 1.52 2.75 19 23 25 28 1.22 3. In.88 7.48 2.09 0.47 0.50 – – – – – 3. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories reducinG tees dIMEnSIonS/WEIGHtS – rEducInG tEES Fig.12 1.32 1.00 76 83 – – – 3.19 5.03 4x4x1 4 x 4 x 1 ⁄4 1 – – – 3. 6075 Groove x Cup E to E In.5 0.12 1.27 0.09 1.9 3.48 4.0 27.0 1.59 0.6 85. Lbs.88 3.5 3./mm E to E In.29 83.125 130.58 0.62 1./kg Cup Length In.1 27.38 3.99 1.6 0.78 3 x 11⁄2 3x2 3 x 21⁄2 4x2 4 x 21⁄2 4x3 5x3 5x4 6x3 6x4 6x5 8x6 – – – – 4.11 1.38 0.85 0. Wt.78 6.96 0.96 2.9 3.12 .7 4.76 0.7 88.34 0.34 1.75 76.26 1.125 54.38 111.9 127./mm Figure 6084 Flange aDapTer Nominal Size In.7 bar). The flange is epoxy powder coated.24 0.7 34.2 98.6 89.91 0.7 24.15 Copper Tube Diameter In./mm DimenSionS/WeighTS – reDuCerS Nominal Size In.0 0.27 1.34 34. The CTS Copper Flange Adapter (Sizes 2" thru 6") conforms to ANSI class 125/150 bolt patterns and is rated at 300 PSIG (20.58 0.8 93.97 0.00 124 www.625 66.2 3.1 0.58 0.70 3.26 4. Wt Ea.8 88.78 2.38 98.4 88.39 2. 6072 Groove x Groove E to E In.5 87.9 1.45 3.6 23.17 0.73 0.anvilintl.00 3.1 83.7 76.com GL-10.6 4.68 104.32 0.125 79.61 21⁄2 x 11⁄2 2 ⁄2 x 2 1 3.6 74.59 0.5 4.6 85.71 1.30 1.26 0.55 0.43 1. 6084 Flange Adapter allows for direct connection of Class 125 or Class 150 flanged components to the CTS Copper System.4 82./mm Approx.00 120. Lbs.0 76. 2x1 2 x 11⁄4 2 x 11⁄2 21⁄2 x 1 2 ⁄2 x 1 ⁄4 1 1 – – – – – – 3.5 63.30 3.00 2.9 2.36 0.09 0.88 3.2 68.38 0./kg Wt.78 0.94 3.6 101.87 2.60 2.97 1./kg 2 2½ 3 4 5 6 2.16 0. 6075 Fig.09 1.2 – – – – 88.50 2.91 0.6 – – – – – – – – – – – – 0.75 – – – – – – – – – – – – – – – – 1.3 4. 6084 Flange Adapter E to E E to E Cup E to E Fig./mm Fig.125 155. Ea Lbs. Ea.125 104.0 5.97 2.34 34.7 63.10 2.5 3.0 27.84 0.34 0.97 1.26 – – – – – – 2.27 0.80 6. 6072 Fig.51 0.22 2.17 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 3.7 24.28 0.CTS Copper SySTem ConCentriC reduCers Fig. The Gruvlok® Fig.50 120.6 23.52 3.44 0.0 1.25 3.53 0.5 3.2 76.9 3.89 0.10 – – 5. 44 341.00 50.43 112. NOT RECOMMENDED FOR USE IN PETROLEUM APPLICATIONS.63 66.13 155.22 56.8 4. UPC.7 4.85 97.8 3 4 5 6 3.7 13. ASTM A564 CERTIFICATIONS: ANSI/NSF61 for use in Cold +86F(+30C) and Hot +180F(+82C) potable water systems.84 198.7 3. This valve features a 10 position lever handle.4 4.7 12.7 13.3 4.50 266.5 18 8.8 4.6 5.8 2. Ductile Iron DISC ENCAPSUALTION: Grade “EP” EPDM Rubber: Service temperature range: -40˚F to +250˚F (-40˚C to +121˚C).00 50. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories series 6700 material specifications VALVE BODY: ASTM B584 C89836.4 2.3 10. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.7 3.50 266.ctS coPPEr SYStEM CTS Copper Butterfly Valve The lever handle bronze body butterfly valve is designed for use with grooved copper tubing (CTS).125 79.2 10. fittings and couplings. diluted acids.5 10.20 182.77 95. Bronze. Copper Tube Diameter In. Low Lead DISC: ASTM A536 Gr.6 10./mm Dimensions A In.13 104.8 4./mm E In.31 287.72 119.625 66.27 260.39 314.08 130. Recommended for water service.com GL-6.77 95.00 50.13 79. bronze body and EPDM rubber encapsulated disc. UPPER & LOWER SHAFTS: Stainless Steel Type 17-4PH.2 11.8 6.anvilintl.6 5.39 314.9 3.88 149.83 97.9 8. 65-45-12./mm F In.6 2./mm B In.6 2.44 341./mm J In.22 132.1 www.97 227.43 112.4 2.8 2.50 266.125 155.2 5./mm H In.8 4.43 112.00 50.88 149.8 10.75 146. Annex G.8 4.5 8 3.4 2.4 4. and oil-free air./kg 2 ⁄2 1 2.11 125 .125 104.10 78./mm D In.5 2.43 112.63 117.8 5./mm G In.6 3. Both bronze valve body and the EPDM rubber disc obtained certification to ANSI/NSF 61 for use in potable water systems and is rated to 300 PSI.4 3.4 6.7 12. J H F NSF/ANSI 61 Hot Water / Annex G E øC D B A G SErIES 6700 ctS coPPEr ButtErFLY VALVE dIMEnSIonS Nominal Size In.8 4.125 130.3 7.4 3.81 325.5 14 6.5 7.7 12.5 4 1.2 5.13 130.36 110.43 112.60 65. alkaline solutions.8 5./mm Weight Lbs.5 5 2.50 266.9 4.00 50./mm C In.9 10.50 266. 11 .6 .17-4 PH S/S 126 www.ctS coPPEr SYStEM series 6700 20000 10000 9000 8000 7000 CTS Copper Butterfly Valve Values for flow of water at +60˚F (+16˚C) Q Cv = ∆P Where: Cv = Flow coefficient Q = Flow (GPM) ∆P = Pressure drop (psi) 6" 6000 5000 4000 3000 2000 5" 4" 3" 21/2" Flow (Water) .2 . Handlever 1 Shaft 1 .anvilintl.9 Pressure Drop .7.5 .gpm 1000 500 400 300 200 100 90 80 70 60 50 40 30 20 10 .8.6" 67 Series 6700 Valve Size 900 800 700 600 1 Disc Coating 1 .None 1Operator 1 .3 .EPDM (Grade EP) 0 .com GL-6.10 Pos.psig 1 2 3 4 5 6 7 89 10 20 GruVLoK ctS coPPEr ButtErFLY VALVE SErIES 6700 (ordErInG InForMAtIon) Sample Part Number 4" 6711-1 ––> 1 4" Size 2 /2" .4 .1 . /mm Approx.125 53.125 79.12 127 .85 1.94 4 100 4.0 101. 7091 DI-LOK Fitting prevents the formation of a galvanic cell between grooved end steel pipe and copper tube. see “Fig.32 .30 6.38 3.375 60. 7091 material specifications HOUSING: Seamless Carbon Steel to ASTM A106 COATING: Nylon conforming to ANSI/NSF-61 E to E IPS D D CTS FIGurE 7091 dI-LoK nIPPLE Nominal Size IPS Copper (CTS) D Actual In. 7012 Gruvlok Flange”.66 4.28 6.500 114.7 bar) in a wide range of applications.0 152.62 2.27 1. Lbs.125 155. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. The DI-LOK Fitting is designed for use at temperatures from -40˚F to 230˚F (-40˚C to 110˚C) and pressures to 300 psig (20. Ea.60 1.625 168.0 152./mm Steel (IPS) D Actual In. 7400 Gruvlok Rigidlite Coupling” and “Fig./Kg 2 50 2.dI-LoK® nIPPLES Gruvlok® DI-LOK™ CTS Groove x IPS Groove Dielectric Fitting The Gruvlok Fig. “Fig.78 4.68 2. www.40 9.03 6.98 2.40 2.58 6.33 4.40 4. Wt.0 152.0 152.anvilintl.40 5.60 21⁄2 65 2.38 For installation and assembly of grooved-end connections. The separation of copper from steel by the fitting virtually eliminates the galvanic cell created by the dissimilar metals.90 6.com GL-7. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.29 3 80 3.55 6 150 6.625 66./mm End to End In.875 73.125 104.500 88. 6400 Gruvlok Rigid Coupling”. manifold piping and oilfield services.0 600 41.625 219. GASKET: Grade E (EPDM) or Grade T (Nitrile) Elastomers with properties as designed by ASTM D 2000 for each gasket grade. For externally coated pipe applications.5 4. Max Ft. *Bolt torque ratings shown must be applied at installation.500 88.0 21⁄2 65 2.4 3.773 25.68 47⁄8 124 81⁄8 206 31⁄2 89 3 ⁄4 x 41⁄2 - 200 271 250 339 10. of Pressure Load Grippers PSI/bar Lbs.625 168. In. FIGurE 7005 rouGHnEcK® couPLInG Nominal Size In.1 300 20.341 46.507 37.4 8 200 8.8 10./mm Max. 128 www./N-m Ft.PLAIn-End FIttInGS fiG.D./mm Specified Torque § Approx.4 150 10./mm Coupling Bolts Qty. The unique gripper action provides a positive pipe joint and allows for working pressure ratings up to 750 PSI (52 bar).8 30. Not for use in copper or PVC systems.8 4 100 4.7 3.95 163⁄4 425 221⁄8 562 61⁄4 159 1 x 61⁄2 - 550 746 700 949 88 39. Roughneck Couplings are designed to be used on plain-end pipe and Gruvlok Plain-End Fittings only.1 8. 3 80 3.84 7 ⁄2 1 11 ⁄8 1 4 ⁄8 3 ⁄8 x 5 - 250 339 300 406 23.anvilintl.-Lbs. § – For additional Bolt Torque information. HDPE.563 141.anvilintl.7 27. Grade 32510.000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B./DN(mm) Gasket Pipe Housing Grippers O.375 60.4 Working pressure and end load are based on a properly assembled Roughneck coupling with bolts fully torqued to the above specifications. 2 2 2 2 2 2 4 4 4 4 4 5 Y In. oval-neck track head bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110. plastic. BOLT & NUTS: Heat treated. 10”-16” heat treated stainless steel. Min.000 355.3 30.6 200 13.157 31. material specifications HOUSING: Ductile Iron conforming to ASTM A 536. Not recommended for use on steel pipe with a hardness greater than 150 Brinell.8 191 283 111 6 150 6. Bolts and nuts are provided zinc electroplated as standard./mm Size In.788 136.528 77.98 147⁄8 378 201⁄4 514 53⁄8 137 1 x 61⁄2 - 550 746 700 949 56 25. Wt.2 31.500 114.4 14 350 14.1 See Coupling data chart notes on page 17.4 7. visit our website at www. End No.84 63⁄8 162 93⁄8 238 41⁄8 105 3 ⁄4 x 41⁄2 7 200 271 250 339 16.875 73.3 350 24.750 273.7 14.895 17. Wk.9 16 400 16. on plain-end or beveled standard wall steel pipe and Gruvlok Plain. cast iron or other brittle pipe.000 406. see page 190. Ea./kN Coupling Dimensions X In. contact an Anvil Representative.com or contact an Anvil® Sales Representative.3 750 51. See Installation & Assembly directions on page 168.4 5 125 5.4 3.7 17. process piping. or J995 Grade 2.229 121.97 107⁄8 276 141⁄2 368 41⁄2 114 ⁄8 x 5 - 250 339 300 406 38.Color: Orange Standard Hot dipped Zinc Galvanized (Optional) Other Colors Available (IE: RAL3000 and RAL9000).750 323.919 141.1 300 20. For Listings/Approval Details and Limitations.33 41⁄4 108 71⁄8 181 31⁄2 89 5 ⁄8 x 31⁄4 - 150 203 190 257 7.12 ./mm Z In.4 5.1 12 300 12. GRIPPERS: 2"-8" heat treated.7 10./N-m Lbs.3 450 31.3 300 20.End Fittings.9 600 41./Kg 2 50 2. The Roughneck Coupling is ideal for use in a variety of applications including mining.9 250 17.0 7. COATINGS: Rust inhibiting paint .6 17.78 8 8 8 8 8 12 12 8 12 12 12 33⁄4 95 63⁄8 162 31⁄2 89 ⁄8 x 31⁄4 - 150 203 190 257 6.5 10 250 10.-Lbs.00 83⁄4 222 127⁄8 327 43⁄8 111 1x6 7 250 339 300 406 31. Max.159 134.15 183⁄4 476 24 610 61⁄4 159 1 x 61⁄2 - 550 746 700 949 95 43.12 125⁄8 321 18 457 53⁄8 137 1 x 61⁄2 - 500 678 600 814 40 18.com GL-7. 7005 Roughneck® Coupling The Fig.323 14. Grade 65-45-12 or Malleable Iron conforming to ASTM A 47. electroplated carbon steel.6 3. For other Coating requirements contact an Anvil Representative. 7005 Roughneck Coupling is an effective and reliable way of joining plain-end or beveled end pipe. 3 91⁄2 241 13.3 57⁄8 149 13.6 7 178 9. Lbs.625 219.D.000 101.2 4. Type “F”.8".45° Elbow E C to O./Kg O. 7060p .8 2. fiG. Wt.3 53⁄4 146 18.8 31⁄2 90 4.6 21⁄2 65 2.D./DN(mm) O.9 33⁄4 95 4.000 101. Lbs.7 1.625 219.0 0.0 43⁄4 121 6./mm 2 50 2.1 The Fitting Size Chart is used to determine the O.0 51⁄2 140 4. C to E FIGurE 7050P 90° ELBoW Nominal Size In.PLAIn-End FIttInGS Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.5 8.6 51⁄2 140 11 5.000 101.625 168./mm Nominal Size In.9 14. Grade “B”.500 114.5 1. Carbon Steel pipe conforming to ASTM A 53./mm Nominal Size In.3 67⁄8 175 21. In.0 4 100 4.D. Other coatings including Hot Dipped Zinc Galvanizing./Kg FIGurE 7060P tEE Approx.625 168.563 141.6 4 100 4.7 17. fittings are either segment-welded steel or forged steel. fiG.3 5. In. Ea. 7050p . Lbs.6 4 102 6.875 73.7 9./mm Approx.D.8 2.375 60.6 21⁄2 65 2.3 8 200 8.9 2 50 2.3 3 80 3.1 10 254 61.D./DN(mm) O./mm. Ea. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok plain-end fittinGs Gruvlok plain-end fittings are manufactured to provide minimum pressure drop and uniform flow.2 3.2 3 80 3.0 5 140 5.0 8 200 8.500 88.625 168.D.com GL-6./DN(mm) FIGurE 7051P 45° ELBoW Approx. Wt.563 141.9 31⁄2 90 4.anvilintl.3 51⁄8 130 9./mm Center To End In./Kg 2 50 2.8 6.625 219. fiG.6 4 100 4. are available. Fittings are designed for use with the Fig.625 219.5 Class 300 .5 1.3 75⁄8 194 30.1 6 152 24.3 5 125 5.8 3 80 3.9 51⁄8 130 8.D.3 4 100 4.2 2.3 31⁄2 90 4. Gruvlok® Fittings are identified by either the Nominal size in inches or the Pipe O.563 141. Ea.6 8 200 8.0 31⁄2 89 3.500 88.375 60. Wt.2 2 50 2.11 129 .875 73./DN(mm) O. In. In. In.9 61⁄4 159 7.4 6.1 11 279 38. Gruvlok plain-end fittings are available in sizes through 8" nominal pipe size in a variety of styles.1 27. FIttInG SIZE Nominal Size In.875 73. of the pipe that the fittings is to be used with.500 88.375 60.4 4.3 material specifications SEGMENT WELDED STEEL FITTINGS: Sizes 2" .6 3.500 114.3 21⁄2 65 2.D. Depending on size and configuration. STEEL FITTINGS: Forged Steel conforming to ASTM A 106.Tee O.500 88.9 11.2 21⁄2 65 2. 7051p .563 141./mm Center To End In.3 73⁄4 197 12.3 41⁄4 108 8. Fittings are normally coated with a rust inhibiting paint.1 6 150 6.500 114.90° Elbow C to E O.Carbon Steel conforming to ANSI B16.000 101. Sizes 5" .500 114.2 5 125 5.2 2.3 31⁄8 79 2.4" Carbon Steel pipe conforming to ASTM A 53.D.3 3 80 3.4 6 150 6.7 www.9 6 150 6. 7005 Roughneck Couplings only.8 6 150 6.1 5 125 5./mm Center To End In.3 43⁄4 121 2.5 31⁄2 90 4.3 11 279 31 14.0 3./mm Nominal Size In./DN(mm) O.D.3 41⁄4 108 3.6 8 200 8.375 60.875 73. ADAPTER FLANGES: Class 150 .Carbon Steel conforming to ANSI B16. Type “E” or “S”.625 168. In. 0 3.3 168.7 17 2 ⁄2 65 80 2.2 5.375 60.500 5.6 88./mm Lbs.500 4.5 12.3 141. 7050lrp .3 5.90° LR Elbow C to E O.3 219. Lbs.2 42.9 9.0 48.6 114.9 6.7 50 2 1 2. Lbs.1 2 ⁄2 65 80 2. Ea.000 4.45° LAtErAL Nominal Size In.6 11.8 3.9 2./mm Approx./Kg O. Wt.0 88.3 141.9 4.0 130.0 92.375 60.D.2 14.6 fiG.4 39.1 3./Kg O. Ea.8 22.1 17./Kg 80 x 80 x 50 100 x 100 x 50 100 x 100 x 65 100 x 100 x 80 150 x 150 x 50 150 x 150 x 80 150 x 150 x 100 200 x 200 x 50 200 x 200 x 80 3x3x2 140 149 149 149 194 194 194 254 254 51⁄2 57⁄8 7 7.0 60.4 2.0 20. 7061p ./mm 90° Lr ELBoW Nominal Size In.500 5./mm Approx./mm Center To End In. Wt.3 114.500 4.3 141.0 74.D.5 21.5 1.563 6.0 88.0 21.9 21.4 200 x 200 x 100 200 x 200 x 125 200 x 200 x 150 250 x 250 x 100 250 x 250 x 150 250 x 250 x 200 300 x 300 x 150 300 x 300 x 200 300 x 300 x 250 8x8x4 8x8x5 8x8x6 254 254 254 10 10 10 1 46. In.0 14.1 33.2 4.2 1.5 10.500 5.3 219.5 4.Cross C to E C to LE fiG./mm In.9 108 121 130 140 149 175 194 254 41⁄4 4 ⁄4 3 23⁄4 70 76 3.D.9 184 197 222 254 71⁄4 7 ⁄4 3 23⁄4 70 76 5.375 60.9 73./mm Lbs.563 6.croSS Nominal Size In.D. Ea./DN(mm) FIGurE 7069P .4 9./Kg 50 2 1 2.8 5.2 10.0 50./DN(mm) FIGurE 7071P ./DN(mm) O./mm Center to Center to Approx.1 4 ⁄4 51⁄8 7.3 168.8 10.8 53.6 31. In.500 4. In.9 24.1 5.6 11.625 123⁄4 14 18 4 38.0 44.7 12. Ea.1 2.D.5 11.8 20. 7068p ./Kg Center To End In.3 168.3 5.625 8.8 50 2 1 2. FIGurE 7061P rEducInG tEE Nominal Size In.7 25. C to SE C to LE C to SE FIGurE 7068P . fiG.875 3. In.5 9.6 2.3 73.000 101./DN(mm) O./mm In.0 4 37.5 56.8 11.2 24.4 2. fiG.com GL-6.D.3 3 3 83⁄4 10 31⁄4 83 3 51⁄8 51⁄2 31⁄4 83 89 95 31⁄2 90 100 125 150 200 51⁄2 57⁄8 67⁄8 75⁄8 10 31⁄2 90 100 125 150 200 31⁄2 89 31⁄2 90 100 125 150 200 31⁄2 33⁄4 102 114 152 4 5 6 8 4.7 4 5 6 8 4.1 168./mm Center To End In. Ea.0 78.5 41.1 17.3 141.3 101.1 103⁄4 273 324 356 457 33⁄4 95 102 114 152 22.0 50.875 3.500 114. Lbs.7 33. In. Wt.9 6.D.1 3 6.0 88.7 74.3 4.0 118. O.0 86.875 3./DN(mm) FIGurE 7050 LrP Approx.2 11.D.625 8.563 6.8 2 ⁄2 65 80 2.0 54.2 8.3 127 146 165 184 203 5 3 2.Reducing Tee C to E O.3 73.875 3.9 108 121 130 140 149 175 194 254 41⁄4 3 4.6 35.625 8.375 2.7 13.45° Lateral O.625 8.0 112.000 101./DN(mm) Center To End In.6 41⁄2 6 41⁄2 6 53.625 219.3 73./mm Approx.625 4 5 6 8 4.0 111⁄4 286 381 248 93⁄4 15 12 x 12 x 10 130 www./mm Center to Center to Approx.6 114.90° truE WYE Nominal Size In.2 24. 7071p .7 12.11 ./Kg Nominal Size In.3 11.4 26.1 20.2 7.90° True Wye C to LE O.D.5 59.5 28.000 101.1 5 ⁄4 61⁄2 10 x 10 x 4 10 x 10 x 6 10 x 10 x 8 12 x 12 x 6 12 x 12 x 8 11 ⁄2 292 292 292 343 343 343 3 75⁄8 75⁄8 75⁄8 10 10 111⁄2 111⁄2 131⁄2 131⁄2 131⁄2 31⁄2 100 125 150 200 71⁄4 8 4 5 6 8 25.3 219. Wt. Ea.563 6.500 4. In.625 57⁄8 67⁄8 75⁄8 10 26.9 19.0 4x4x2 1 11.8 5.5 6.6 3 9.0 4 x 4 x 2 ⁄2 4x4x3 6x6x2 6x6x3 6x6x4 8x8x2 8x8x3 5 ⁄8 5 ⁄8 7 2 ⁄2 1 50 65 80 90 2 2. 7069p .5 4. Long End Short End Wt.PLAIn-End FIttInGS Gruvlok plain-end fittinGs fiG. Long End Short End Wt.anvilintl. Lbs.0 9. Bull Plug E to E O./mm Approx.0 15.0 88.1 8./Kg O.3 219.2 4.6 5 3. O.875 3.9 102 127 152 165 178 216 254 279 4 2.4 5.625 8.563 141.com GL-6./DN(mm) O.4 3 80 3.4 4.1 6 152 43. Wt.0 13.PLAIn-End FIttInGS Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs./Kg Approx.7 3 4 3 6 31⁄2 90 100 125 150 200 41⁄4 41⁄2 53⁄8 6 8 6.2 3.6 3 ⁄4 95 102 108 114 137 152 203 3.9 33⁄8 86 3 1.5 13.000 101.3 73.7 6 152 72.7 6 152 28.5 4 100 4./mm FIGurE 7085P End To End In.5 7.11 131 .0 12.3 168.anvilintl./DN(mm) to FIGurE 7075P ./mm Approx./Kg O. Lbs.3 4 102 6. In.5 5.4 2.625 81⁄2 10 11 12.0 4 102 9./mm PLAIn-End X cLASS 300 FLAnGE nIPPLES End To End In. Wt. Ea.8 1.8 4 5 6 8 4.0 2 ⁄2 65 80 2.3 6 152 23.1 5.D.5 3.625 8.4 4 102 21.0 31⁄2 90 4.500 114./mm Center To End In.0 2.000 101./mm Approx.5 19. Lbs.0 32.0 9.0 6./mm Center To End In.45° Lr ELBoW Nominal Size In. In.6 50 2 1 2. Ea. Ea.7 5 125 5. In. 7084p & fiG.7 4 102 15.7 21⁄2 65 2.8 17.9 6 150 6.0 1.000 101./Kg 50 2 1 2. Lbs./DN(mm) 2 50 2.375 60. Ea.7 8 200 8.9 5.500 4.500 114.875 73.500 88.3 141.D.3 1.3 141.3 219. In. 7051lrp .5 7.3 7. Wt.8 0.3 168.500 114.5 17.7 www.6 4 102 14. 7085p (Plain-End x Class 150 or 300) Flange Nipples E to E FIGurE 7084P PLAIn-End X cLASS 150 FLAnGE nIPPLES Nominal Size O.1 7.2 fiG.6 4.45° LR Elbow E C fiG.3 6 152 19.0 22.375 60. FIGurE 7051 LrP .2 4 102 11.4 6 152 35.4 6 152 50.0 4.5 2.9 4 102 10.500 4.625 219.875 3.4 5.563 6.D. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok plain-end fittinGs fiG.563 6.375 60.7 3.5 3.7 4 102 8. 7075p .0 29.BuLL PLuG Nominal Size In.5 2 ⁄2 65 80 2.0 2.3 6 152 29.D.D.625 13.4 6.0 15.0 88. Lbs.7 7.0 10.625 168.3 34.3 73.D. Wt.0 31⁄2 90 100 125 150 200 61⁄2 7 4 5 6 8 4. D.7 7./Kg Nominal Size In.5 11. 132 www.500 114.5 11.0 2. Ea.D.5 11.0 29.5 3.0 See chart on page 129 for O.2 0.anvilintl. 7082p Plain x Bevel E to E O. Ea.6 4 1.3 73.0 13.D.5 7.3 6.0 7.2 6 x 21⁄2 6x3 6x4 6x5 8x3 8x4 8x5 8x6 12 17.D.4 5.5 3./Kg 50 2 1 2.0 17. Lbs.7 7.7 7.5 0.D.3 168./DN(mm) FIGurE 7080P.4 fiG.PLAIn-End FIttInGS Gruvlok plain-end fittinGs adapter nipples fiG. 7082P AdAPtEr nIPPLES O.1 1. 7081P.1 6 6 6 6 5.5 7.9 102 102 102 102 152 152 152 152 4 1./Kg E to E O. 7081p Plain x Thread E to E O.375 60./DN(mm) 21⁄2 x 2 65 x 50 80 x 50 178 203 203 229 229 229 279 279 279 7 3. Wt. In. Lbs./mm Approx. 7077p Swaged Nipples Nominal Size FIGurE 7077P SWAGEd nIPPLES End Center To End In.875 3. In.5 3.0 1.4 3.5 14. 7080p Plain x Grooved E to E O.D.1 5.2 13.0 88.7 7.2 5.625 8. Wt./DN(mm) End Center To End In.3 219.11 . Wt.4 3./mm End To End In.2 13.4 4.2 3 x 21⁄2 80 x 65 100 x 50 100 x 65 100 x 80 125 x 50 125 x 80 125 x 100 8 12 12 12 13 13 13 13 4x2 9 4 x 21⁄2 4x3 5x2 5x3 5x4 9 7. 2 ⁄2 65 80 2.0 17.563 6.2 13.0 29. Lbs.625 7.9 2./mm Approx. 150 200 fiG.2 5.5 9 11 11 11 29.500 4.9 1. Nominal Size In.com GL-6.0 150 x 50 150 x 65 150 x 80 150 x 100 150 x 125 200 x 80 200 x 100 200 x 125 200 x 150 6x2 305 305 305 305 305 330 330 330 330 12 17.0 29.0 17.3 141./mm Approx.2 fiG.7 3x2 8 4. Ea.5 4.4 2.4 3 4 31⁄2 90 100 125 4 4 5 6 8 4.000 101.4 9.5 2. D 3035.hdpe couplings HDPE Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories FIG. materIal specIFIcatIons HOUSING: Ductile Iron conforming to ASTM A 536. Each coupling uses four bolts to drive the sharply machined housing teeth into the outside of the pipe. The Figure 7305 features a low profile contoured housing with a ramp along the outside diameter allowing the coupling to glide over most obstacles. For specific chemical applications. Consult the HDPE pipe manufacturer for the temperature and pressure ratings. Grade T Nitrile (Orange color code) Service Temperature Range: -20°F to 180°F (-29°C to 82°C). GASKETS: Properties in accordance with ASTM D 2000 Grade E EPDM (Green color code) Service Temperature Range: -30°F to 230°F (-34°C to 110°C). This cost effective easy to assemble mechanical joint is used to join SDR 32. each bank consisting of at least three rows of spiral teeth which effectively grip the pipe. alkaline solutions. The teeth are arranged in two banks. www. while long lengths of the pipeline are being relocated. NOT FOR USE IN PETROLEUM APPLICATIONS.anvilintl. reference the Gruvlok Gasket Recommendations section of the Gruvlok catalog. dilute acids. Gruvlok products for HDPE pipe must be installed using Gruvlok XtremeTM Temperature Lubricant. carbon steel oval-neck track bolts conforming to ASTM A 183. oil free air and many chemical services.3 wall thickness HDPE pipe conforming to ASTM D 2447. Grade 65-45-12 COATING: Rust inhibiting paint – Color: Orange Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. Zinc electroplated carbon steel heavy hex nuts conforming to ASTM A 563 Grade A or Grade B.com GL-7. 2. ANSI BOLTS & HEAVY HEX NUTS: Heat treated. providing a secure mechanical joint with pressure capabilities exceeding that of the HDPE pipe itself.5 to 7. air with oil vapor. Recommended for water service. NOT FOR USE WITH HOT WATER OR HOT AIR.12 133 . The banks of teeth are positioned away from the gasket enhancing the sealing ability of the gasket throughout its operating temperature range. WARning: 1. vegetable and mineral oils. zinc electroplated. D 3000. The gasket temperature rating may exceed the manufacturer temperature rating for the HDPE pipe. or F 714 and eliminates the need for costly fusion equipment. Recommended for petroleum applications. 7305 The Gruvlok Figure 7305 couplings are designed for mechanically joining HDPE (high density polyethylene) pipe and fittings. or J995 Grade 2. 3 0.204 5.6 10 250 10. Wt.1 0.1 0.4 6 150 6.138 3.99 0.9 0.3 0.075 1.6 0.D.5 12 300 12./mm Out Of Roundness Tolerance +/In.327 8.500 88.1 0. Lbs.048 1.4 0.5 3.427 10.02 0.977 24.HdPE couPLInGS fiG.9 143⁄8 365 177⁄8 454 71⁄4 184 3 ⁄4 x 43⁄4 - 58 26.1 0.9 0.958 24./DN(mm) O.632 16.6 0.7 10 250 10./mm SDR 9 In.76 0.479 12.45 0.290 7.5 0.512 13.140 3./mm 2 50 2.226 5.340 8.7 0.500 114.016 0.625 168.8 0.375 60.1 10 254 131⁄4 337 6 152 5 ⁄8 x 31⁄2 - 30 13.030 0.15 0.4 1.006 0.020 0.607 15.035 0.5 In.3 0.216 5.1 0.182 30.750 19.D.3 0.3 0.6 0. Per ASTM D 2447 and D 3035 See Installation & Assembly directions on page 171.2 4 100 4.91 1./mm FIGurE 7305 HdPE couPLInG Coupling Dimensions X In.9 0.51 0. 7305 HDPE Coupling Y Nominal Size O.1 0.3 0.750 323.500 88.anvilintl.625 168.214 5./mm SDR 17 In./mm 2 50 2.075 1.473 37.325 8.0 3 80 3.823 20.375 60. Approx.41 0.7 0.057 1.625 219.050 1.039 0.4 0.7 0. 4 4 4 4 4 4 4 5 1 Y In.1 12 305 153⁄4 400 61⁄2 165 3 ⁄4 x 43⁄4 - 43 19. Per ASTM F 714 2./mm SDR 15. Ea.0 0./mm SDR 21 In.264 6.331 8.4 12 300 12.556 14.5 2.7 3 80 3./mm Coupling Bolts Z Qty.040 1.5 In.8 0.89 0.113 2.com GL-6.736 18.750 273.3 0.167 4.500 114.2 0.0 1.7 0.908 23.11 .3 In.784 19. Actual In.040 1.9 0. In.3 71⁄2 191 11 279 57⁄8 149 ⁄8 x 31⁄2 - 18 8.409 10.6 0.206 5.4 0.4 0.22 0.194 30./mm Tolerance +/In.075 1.9 0./mm SDR 32.159 29.153 3.3 HdPE PIPE dIMEnSIonAL SPEcIFIcAtIonS Nominal Size In.616 15.9 0.7 0.500 12./mm Pipe Wall Thickness SDR 7.91 1.0 1.265 6.9 45⁄8 117 63⁄4 171 45⁄8 117 ⁄2 x 3 - 8.5 6 150 6.265 6.4 1.1 0.750 273.0 0.27 0. 134 www.91 1.02 0.3 0./DN(mm) In.3 33⁄8 86 51⁄2 140 45⁄8 117 ⁄2 x 23⁄8 1 4.108 2.389 9.602 15./Kg X In.747 44.625 219.2 8 200 8.9 Z 4 100 4.750 323./mm Size In.9 0.2 0.392 10.318 8./mm SDR 11 In.417 36.3 51⁄4 133 8 203 53⁄4 146 1 ⁄2 x 3 - 12 5.9 0.265 6.694 17.2 8 200 8.4 0.7 0.507 12. The coupling can be used with HDPE pipe having SDR values of 7.hdpe couplings HDPE Transition Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. For specific chemical applications. Grade 65-45-12 COATING: Rust inhibiting paint – Color: Orange Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade T Nitrile (Orange color code) Service Temperature Range: -20°F to 180°F (-29°C to 82°C). ANSI BOLTS & HEAVY HEX NUTS: Heat treated. reference the Gruvlok Gasket Recommendations section of the Gruvlok catalog. The temperature and pressure capabilities of the Figure 7307 exceed the highest temperature and pressure ratings of the HDPE pipe. as well as with grooved-end fittings and valves. oil free air and many chemical services. Consult the HDPE pipe manufacturer for the temperature and pressure ratings. NOT FOR USE WITH HOT WATER OR HOT AIR. or F 714) to roll grooved or cut grooved standard weight and. that engages specifically grooved steel pipe or fittings. Recommended for water service. alkaline solutions.anvilintl. zinc electroplated. The gasket temperature rating may exceed the manufacturer temperature rating for the HDPE pipe. vegetable and mineral oils. Zinc electroplated carbon steel heavy hex nuts conforming to ASTM A 563 Grade A or Grade B. D 3000. The Figure 7307 incorporates two banks of machined teeth on one side of the housing. WARning: 1. D 3035. dilute acids. 2. and a key section on the other. www.12 135 .com GL-7. GASKETS: Properties in accordance with ASTM D 2000 Grade E EPDM (Green color code) Service Temperature Range: -30°F to 230°F (-34°C to 110°C). Recommended for petroleum applications. carbon steel oval-neck track bolts conforming to ASTM A 183. The Figure 7307 features a low profile contoured housing with a ramp along the outside diameter on the half of the HDPE coupling. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories FIG. roll grooved lightweight pipe. This easy to assemble mechanical joint is used to join HDPE pipe (conforming to ASTM D 2447. air with oil vapor. or J995 Grade 2.5.3 to 32. The banks of teeth are positioned away from the gasket enhancing the sealing ability of the gasket. 7307 The Gruvlok Figure 7307 HDPE transition coupling allows for transition from HDPE pipe or fittings to grooved-end pipe prepared per Gruvlok standard cut or roll groove specifications for steel pipe or Gruvlok fittings. materIal specIFIcatIons HOUSING: Ductile Iron conforming to ASTM A 536. Gruvlok products for HDPE pipe must be installed using Gruvlok XtremeTM Temperature Lubricant. 216 5.057 1.389 9.318 8.214 5.625 168.7 0.512 13./mm Out of Roundness Tolerance +/In.D.7 0. Actual In./mm Coupling Dimensions X In./mm Tolerance +/In./mm Pipe Wall Thickness SDR 7.226 5.com GL-6.1 0.7 3 80 3.479 12./mm SDR 9 In.750 273.206 5.2 0.5 6 150 6.15 0.22 0.507 12.3 10 250 10.1 0.76 0.331 8. Lbs.159 29./DN(mm) O.9 0.167 4.6 0.4 0.6 0. Wt.616 15.473 37.9 0.4 0.27 0. Per ASTM F 714 2.5 9.039 0.006 0.3 In.1 0.1 0./Kg In.3 33⁄8 86 6 152 31⁄8 79 ⁄2 x 23⁄8 1 4.7 0.7 0.048 1.784 19.204 5.1 0.500 12.138 3. 136 www.5 In.5 In.3 HdPE PIPE dIMEnSIonAL SPEcIFIcAtIonS Nominal Size In.3 53⁄4 146 81⁄2 216 33⁄4 95 1 ⁄2 x 3 - 8.625 168.340 8.500 114.51 0.908 23.91 1.1 0.747 44.392 10.7 4 100 4.607 15.02 0.750 323.4 0.9 0.D.5 19.7 0.2 0.500 88.040 1.823 20.5 15.556 14.8 0.2 4 100 4. See Installation & Assembly directions on page 172.040 1.632 16./mm Coupling Bolts Z Qty.736 18.3 0.602 15.327 8.3 0./mm SDR 11 In./mm Size In.500 88.7 0.5 2.194 30.4 0.625 219.020 0.9 0.500 114.409 10.265 6.45 0.1 0.075 1.375 60.6 12 300 12.0 1.0 1.4 12 300 12.9 0.11 .4 1.030 0.625 219.075 1.4 1.9 Z 6 150 6.977 24.375 60.694 17. Actual In.113 2./mm 2 50 2.325 8.264 6.9 0.750 273.0 3 80 3.1 101⁄2 267 135⁄8 346 41⁄4 108 5 ⁄8 x 31⁄2 - 20. 7307 HDPE Transition Coupling Y FIGurE 7307 HdPE trAnSItIon couPLInG Nominal Size In.5 5.9 143⁄4 375 191⁄2 495 5 127 7 ⁄8 x 51⁄2 - 42.02 0.050 1./mm SDR 21 In.075 1.anvilintl.290 7.0 0.2 8 200 8.3 0.9 0.3 0.153 3.5 3.9 41⁄2 114 71⁄8 181 31⁄8 79 ⁄2 x 3 - 6 2.265 6.0 0.3 8 203 111⁄4 286 33⁄4 95 ⁄8 x 31⁄2 - 12.750 19.9 0.3 0./mm X 2 50 2.99 0./DN(mm) O.1 125⁄8 321 17 432 5 127 7 ⁄8 x 51⁄2 - 34.016 0.7 10 250 10.035 0. 4 4 4 4 4 4 4 5 1 Y In.417 36. Per ASTM D 2447 and D 3035 3.41 0.8 0.7 8 200 8.91 1.91 1./mm SDR 17 In./mm SDR 32.HdPE couPLInGS fiG. Ea.427 10.6 0./mm SDR 15.108 2.3 0.958 24.6 0.140 3.182 30./mm Approx. For steel pipe requirements refer to Gruvlok Groove Specifications for steel pipe.750 323.3 0.3 0.265 6.4 0.5 0.89 0. D 3035. 7312 The Gruvlok® Figure 7312 forms a cost-effective. The gasket temperature rating may exceed the manufacturer temperature rating for the HDPE pipe. vegetable and mineral oils. 2. air with oil vapor. Grade T Nitrile (Orange color code) Service Temperature Range: -20°F to 180°F (-29°C to 82°C). each bank consisting of at least three rows of spiral teeth that effectively grip the pipe. Consult the HDPE pipe manufacturer for the temperature and pressure ratings. GASKETS: Properties in accordance with ASTM D 2000 Grade E EPDM (Green color code) Service Temperature Range: -30°F to 230°F (-34°C to 110°C).hdpe couplings HDPE Flange Adapter Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. alkaline solutions. zinc electroplated. oil free air and many chemical services.3 HDPE pipe and fittings conforming to ASTM D 2447. or J995 Grade 2.com GL-7. Recommended for water service.12 137 . D 3000.5 to 7. easy-toassemble mechanical joint between HDPE (high density polyethylene) pipe and fittings and ANSI Class 125 or Class 150 piping components without the need for costly fusion equipment. Each coupling uses two bolts to drive the sharply machined housing teeth into the outside of the pipe. carbon steel oval-neck track bolts conforming to ASTM A 183. materIal specIFIcatIons HOUSING: Ductile Iron conforming to ASTM A 536. The teeth are arranged in two banks. dilute acids. For specific chemical applications. NOT FOR USE IN PETROLEUM APPLICATIONS. Recommended for petroleum applications. Zinc electroplated heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B. Grade 65-45-12 COATING: Rust inhibiting paint – Color: Orange Other Colors Available (IE: RAL3000 and RAL9000) For other Coating requirements contact an Anvil Representative. NOT FOR USE WITH HOT WATER OR HOT AIR. reference the Gruvlok Gasket Recommendations section of the Gruvlok catalog. Gruvlok products for HDPE pipe must be installed using Gruvlok XtremeTM Temperature Lubricant. The banks of teeth are positioned away from the gasket. www. or F 174. WARning: 1. enhancing the sealing ability of the gaskets throughout the entire operating temperature range. The flanged couplings are designed for wall thickness’ SDR 32.anvilintl. providing a secure mechanical joint with pressure capabilities exceeding that of the HDPE pipe itself. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories FIG. ANSI BOLTS & HEAVY HEX NUTS: Heat treated. com GL-7./mm Size In./DN(mm) O./mm B Min.736 18./mm SDR 9 In. use procedure described in note 3. The sealing surfaces A Max./mm Tolerance +/In.7 0.030 0.0 0. 3.050 1.075 1./mm Flange Dimensions X In.HdPE couPLInGS fiG. Wt.D.1 0./mm Size In.409 10./mm Pipe Wall Thickness SDR 7. Grooved Pipe Gruvlok Flange Adapter Insert Grooved Pipe Rubber Surface Gruvlok Flange Adapter Insert Flange Gasket NOTE A NOTES 1 and 2 NOTES 3 and 4 FIGurE 7312 HdPE FLAnGE AdAPtEr Nominal Size In. Gruvlok Flanges are to be assembled on butterfly valves so as not to interfere with actuator or handle operation. of the mating flange must be free from gouges. if the valve is rubber faced in the area designated by the sealing surface dimensions (A Max.76 0.4 0. When mating to a rubber-faced metal flange.51 0. Mating Flange 7312 Flange Component Serrated Face Mating Flange X A max./mm SDR 32.4 0.3 111⁄4 286 123⁄8 314 37⁄8 98 65⁄8 168 73⁄4 197 5 ⁄4 x 31⁄2 ⁄4 x 31⁄2 22 10.3 0.anvilintl.3 9 229 103⁄8 264 31⁄8 79 41⁄2 114 53⁄4 146 ⁄8 x 15⁄8 ⁄8 x 23⁄8 ⁄4 x 23⁄4 ⁄8 x 3 15 6. C.214 5. B min. In.265 6. Per ASTM D 2447 and D 3035 See Installation & Assembly directions on page 173.5 In.500 12.290 7./mm Sealing Surface Z In.7 A. D. Gruvlok Flanges should not be used as anchor points for tierods across nonrestrained joints. B.9 0.625 219. undulations and deformities of any type to ensure proper sealing of gasket.9 0.138 3. Gruvlok Flanges are not recommended for use against formed rubber flanges./DN(mm) O. When mating to a wafer valve (lug valve).7 0.99 0.91 1./mm SDR 11 In.1 131⁄2 343 147⁄8 378 31⁄2 89 85⁄8 219 101⁄4 260 3 3 26 12.7 0. to B Min.1 0.5 6 150 6. place the Gruvlok Flange Adapter Insert between the valve and the Gruvlok Flange./Kg 4 100 4. Per ASTM F 714 2.204 5. In.3 0.625 168. When mating to valves or other component equipment where the flange face has an insert.6 0. HdPE PIPE dIMEnSIonAL SPEcIFIcAtIonS Nominal Size In./mm SDR 17 In.020 0.3 0. E.500 114.040 1.958 24.602 15.7 0.039 0.27 0.0 8 200 8. applications which reQuire a Gruvlok® flanGe adapter insert: 1.3 In.265 6. the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the rubberfaced flange.2 8 200 8. The Gruvlok Flange Adapter Insert is installed between the Gruvlok Flange sealing gasket and the mating flange or surface to provide a good sealing surface area. 7312 Y HDPE Flange Adapter Z Gruvlok Fig. Fig. When mating to a serrated flange surface.616 15. Lbs. a standard fullfaced flange gasket is installed against the serrated flange face. 138 www.182 30.500 114.625 219.427 10.3 0.340 8.265 6./mm SDR 15. 2. 8 8 8 3 Y In. Do not use Gruvlok Flanges within 90 degrees of one another on standard fittings because the outside dimensions may cause interference. In.5 In.327 8. Ea. 7312 Flange Gruvlok Fig.12 . The use of a Gruvlok Flange Adapter Insert is required for applications against rubber faced valves or other equipment.507 12.4 0.908 23. 4.556 14.7 1. 7312 Gruvlok Flange sealing gaskets require a hard flat surface for adequate sealing.6 0.1 0./mm SDR 21 In. to B Min. 2 2 2 5 Mating Flange Bolts Qty. and the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the standard flange gasket. F./mm Latch Bolt Qty. Actual In.)./mm 4 100 4.8 0./mm 5 Approx./mm A Max.3 0.02 0.D.625 168.784 19.8 6 150 6./mm Out of Roundness Tolerance +/In. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories sock-it® pipinG method fittinGs The Gruvlok® Sock-It® Piping Method provides a quick.660 42.D. as specified in accordance with ASTM D 2000 NOTE: All Sock-It® fittings are UL/ULC Listed and FM Approved for 175 psi working pressure when used to join XL Pipe and Dyna-Flow Pipe. material specifications HOUSING: Cast iron ASTM A 126 CLASS A BOLTS: Case hardened carbon steel. Pressure energized elastomeric gaskets provide the Sock-It with a leak tight seal./mm ⁄2 ⁄4 0.9 22 11⁄4 32 1.050 26. in mm./mm Nominal Size In. secure and reliable method of joining plain-end steel pipe.2 31⁄4 83 19⁄16 40 15⁄8 41 23⁄16 56 4. straight tees and reducing elbows.7 300 20.D. In. Specially designed lock bolts secure the pipe in the Sock-It Fitting.3 175 12. providing a fast.7 25⁄8 67 11⁄8 29 13⁄8 35 115⁄16 49 2. 90 elbows.0 11⁄4 32 1./mm Approx./DN(mm) O. In. For Listings/Approval Details and Limitations.0 1.900 48.900 48.7 1.840 21. In.3 11⁄2 40 1.7 300 20./mm Dimensions U* In. See Installation & Assembly directions on page 174.3 300 20.875 73.3 15 3 1.7 300 20.Run take-out dimension.com or contact your local Anvil Sales Representative. straight couplings. Several Sock-It configurations are available: tees with NPT outlets.7 27⁄16 62 1 25 11⁄4 32 113⁄16 46 2. dichromate finish.anvilintl.D.7 21⁄2 65 2.315 33.com GL-7. fiG.4 The Fitting Size Chart is used to determine the O. www.375 60.9 0./mm Max.D.4 300 20.7 25⁄16 59 ⁄8 11⁄16 27 13⁄4 44 1.3 1./mm Y In. reducing run tees with NPT outlets.12 139 .anvilintl. GASKETS: EPDM.7 2 50 2./mm 7 W In. Ea./DN(mm) O.SocK-It® PIPInG MEtHod Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs./DN(mm) 1 O. FIttInG SIZE Nominal Size In. Working pressure ratings shown are for reference only and are based on schedule 40 pipe. For the latest UL/ULC Listed and FM approved pressure ratings versus pipe schedule see www.0 11⁄2 40 1.2 2 50 2.3 20 1 25 1.660 42.com or contact an Anvil® Sales Representative.1 250 17. Wt. visit our website at www. Gruvlok Fittings are identified by either the Nominal size in inches or the Pipe O.8 * “U” . of the pipe that the fittings is to be used with./Kg 1 25 1.315 33. Lbs.375 60.90° Elbow (Sock-It ® x Sock-It®) C to E U W Y FIGurE 7100 SocK-It® ELBoW (S X S) Nominal Size In.7 300 20.D. dependable way of joining small diameter plain-end pipe. Working Pressure UL/ULC Listed PSI/bar FM Approved PSI/bar Center To End In. 7100 .anvilintl. 4 2./mm Z In.com GL-6.315 1. In./mm Z In.1 * “U” . 7101 .7 20.7 20.0 175 300 11⁄16 15⁄16 23 17 21⁄8 25⁄8 67 54 29⁄16 65 76 62 13⁄8 111⁄16 43 35 32 115⁄16 23⁄16 56 49 46 4 ⁄8 51⁄8 6 W U 50 60. Working Pressure UL/ULC Listed PSI/bar FM Approved PSI/bar Dimensions U* In./mm Y In. Wt.0 1.7 17./DN(mm) Max. Ea.900 2./mm Dimensions Center To SE U* In.7 20.0 0.4 33.7 20.315 1.7 20.3 2. 2 175 250 3 fiG.900 2.0 0./mm U* In.7 20.7 300 300 20. Working Pressure UL/ULC Listed PSI/bar FM Approved PSI/bar Center to TE In.7 17.9 1.Straight Tee (Sock-It ® x Sock-It® x Sock-It®) FIGurE 7103 SocK-It® StrAIGHt tEE (S x S x S) Nominal Size In. Lbs.6 1./mm In.5 2. Thread End.7 20./mm 1 1 1 1 W In.9 3./mm Max.1 1.3 12.0 0.660 1.1 1./mm Approx./Kg Z V Y 1 ⁄4 1 25 1 1.7 20.8 300 300 300 300 11⁄16 11⁄16 11⁄16 17 25 25 25 17 17 22 ⁄8 22 ⁄8 11⁄8 29 25 22 ⁄8 1 1 300 300 300 300 300 300 1 1 11⁄4 11⁄8 11⁄8 29 29 32 25 2 2.Coupling (Sock-It Z ® x Sock-It®) Nominal Size Y FIGurE 7107 SocK-It® couPLInG (S x S) O. Lbs./mm Approx.375 48.4 5.9 2.7 20./DN(mm) 1 ⁄4 1 25 32 40 50 1 1.11 ./Kg 25 x 15 1 x 1⁄2 C to TE T W Y 25 x 20 1 x 3⁄4 1x1 20./mm Y In./mm 7 T** In.7 20.5 2. Wt. Wt.D.7 20. Working Pressure UL/ULC Listed PSI/bar FM Approved PSI/bar Dimensions **T In.375 60.7 0.2 2.1 12.Take-out dimension.SocK-It® PIPInG MEtHod sock-it® pipinG method fittinGs fiG.1 11⁄2 x 1 40 x 25 300 300 1 fiG. **“T” ./mm W In. In.7 20.1 2.7 0.7 1./mm V In.7 300 300 17⁄16 17⁄16 17⁄16 19⁄16 19⁄16 19⁄16 111⁄16 111⁄16 111⁄16 43 43 43 40 40 40 37 37 37 25⁄16 25⁄16 25⁄16 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 21⁄2 64 64 64 64 64 64 59 59 59 22 7 ⁄8 11⁄4 x 1⁄2 11⁄4 x 3⁄4 U C to SE 11⁄4 x 1 11⁄2 x 1⁄2 11⁄2 x 3⁄4 C to SE .Outlet take-out dimension.7 1.7 20. Sock-It® End.660 1.3 42.90° Reducing Elbow (Sock-It ® x NPT) FIGurE 7101 SocK-It® rEducInG ELBoW (S X nPt) Nominal Size In.8 W U 11⁄2 2 13⁄8 15⁄8 115⁄16 23⁄16 31⁄4 35⁄8 175 250 * “U” .2 300 13⁄16 21 25 15⁄8 41 51 21⁄4 2 ⁄16 7 300 1 2 57 11⁄16 1 ⁄4 1 27 111⁄16 1 ⁄16 13 43 114 124 130 152 41⁄2 7 2.7 20.7 20.6 2.7 20.1 300 300 300 20.Take-out dimension.7 20.Run take-out dimension.3 1.Center to Sock-It® End C to TE .D./mm W In. 140 www.3 48.Run take-out dimension.5 1.4 33./DN(mm) O.9 1. ** “T” .Center to Thread End * “U” .3 1./mm Approx.1 300 11⁄2 T 40 32 175 20.9 0./mm Y In.7 20.7 20. Ea. Ea.anvilintl.2 300 300 300 6 6 6 6 ⁄4 ⁄4 ⁄4 ⁄4 11⁄16 1 ⁄4 1 27 32 35 41 111⁄16 1 ⁄16 13 43 46 49 56 31⁄8 3 ⁄8 1 79 79 83 92 1. 7107 .7 20.3 42.7 12.7 20.3 1. Lbs. 40 x 15 40 x 20 32 x 25 32 x 20 32 x 15 25 x 25 300 300 22 7 ⁄8 25 7 7 1 11⁄16 11⁄16 11⁄16 11⁄4 11⁄4 11⁄4 13⁄8 13⁄8 13⁄8 35 35 35 32 32 32 27 27 27 111⁄16 111⁄16 111⁄16 113⁄16 113⁄16 113⁄16 115⁄16 115⁄16 115⁄16 49 49 49 46 46 46 43 43 43 1./mm Max.7 20. 7103 ./Kg In.7 20.7 12.5 1.7 20. 1 11⁄2 38 13⁄8 35 21⁄8 54 115⁄16 49 27⁄16 62 43⁄4 121 5.4 21⁄2 x 21⁄2 x 1 65 x 65 x 25 175 12.2 25 7 7 1 13⁄8 35 3 17⁄16 37 7 11⁄4 32 1 113⁄16 46 13 108 108 108 111 111 111 41⁄4 4 ⁄4 1 2.7 300 20.0 0./mm Approx. ** “T” .7 20.7 17.4 * “U” .1 1.2 3.1 250 17./Kg 1 x 1 x 1⁄2 25 x 25 x 15 300 20./mm Y In.7 20.4 1. Lbs.0 1.2 13⁄8 35 13⁄8 35 115⁄16 49 15⁄8 41 23⁄16 56 43⁄4 121 3.7 300 20.2 3. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories sock-it® pipinG method fittinGs fiG.1 3./mm W In.7 300 20.1 12.0 Z V Y T 11⁄4 x 11⁄4 x 3⁄4 32 x 32 x 20 300 20. Lbs.7 300 20.9 1./Kg 11⁄4 x 1 x 1⁄2 32 x 25 x 15 1 3 300 2.2 11⁄2 x 11⁄2 x 1 40 x 40 x 25 300 20./mm U* In.7 1 25 7 13⁄8 35 17⁄16 37 11⁄16 27 111⁄16 43 41⁄4 108 2.2 W U 11⁄2 x 11⁄2 x 3⁄4 40 x 40 x 20 300 20.5 1.2 11⁄2 38 13⁄8 35 115⁄16 49 15⁄8 41 23⁄16 56 43⁄4 121 3. www./mm U* In.7 20.0 11⁄4 x 11⁄4 x 1 32 x 32 x 25 300 20./mm Z In.0 0.1 20.Run take-out dimension.7 1.4 1.1 20.0 0.7 11⁄8 29 13⁄8 35 15⁄8 41 11⁄4 32 113⁄16 46 41⁄4 108 2./mm Y In.7 11⁄8 29 13⁄8 35 13⁄4 44 13⁄8 35 115⁄16 49 43⁄8 111 2.2 17.4 2. Working Pressure UL/ULC Listed PSI/bar FM Approved PSI/bar Dimensions **T In.0 11⁄4 x 1 x 1 300 300 13⁄8 13⁄8 13⁄8 13⁄8 13⁄8 13⁄8 13⁄8 17⁄16 19⁄16 19⁄16 19⁄16 13⁄4 13⁄4 13⁄4 11⁄4 13⁄8 13⁄8 13⁄8 15⁄8 15⁄8 15⁄8 113⁄16 115⁄16 115⁄16 115⁄16 23⁄16 23⁄16 23⁄16 41⁄4 43⁄8 43⁄8 43⁄8 11⁄2 x 11⁄4 x 1⁄2 40 x 32 x 15 40 x 32 x 20 40 x 32 x 25 50 x 40 x 15 50 x 40 x 20 50 x 40 x 25 300 300 300 300 11⁄8 29 25 25 Z V Y T 11⁄2 x 11⁄4 x 3⁄4 11⁄2 x 11⁄4 x 1 2 x 11⁄2 x 1⁄2 2 x 11⁄2 x 3⁄4 2 x 11⁄2 x 1 1 300 300 1 175 175 250 250 11⁄4 32 29 29 49⁄16 116 116 116 W U 11⁄8 11⁄8 49⁄16 49⁄16 175 250 * “U” .9 1 x 1 x 3⁄4 25 x 25 x 20 300 20.Outlet take-out dimension.7 300 20.1 1.7 20.5 2.6 2 x 2 x 3⁄4 50 x 50 x 20 175 12.SocK-It® PIPInG MEtHod Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.7 300 20.1 300 2.3 1.1 175 12./mm Z In.7 300 20./mm W In. 7105 .7 11⁄8 29 13⁄8 35 13⁄4 44 13⁄8 35 115⁄16 49 43⁄8 111 2.1 250 17.1 12.2 2.Run take-out dimension.0 2.2 17./DN(mm) Max. Ea.7 20.1 175 12.9 11⁄2 x 11⁄2 x 1⁄2 40 x 40 x 15 300 20.9 22 7 1x1x1 25 x 25 x 25 300 20.5 1.5 1.Reducing Outlet Tee (Sock-It ® x Sock-It® x NPT) FIGurE 7105 SocK-It® rEducInG outLEt tEE (S X S X nPt) Nominal Size In. Working Pressure UL/ULC Listed FM Approved PSI/bar PSI/bar Dimensions **T In.2 13⁄8 35 13⁄8 35 115⁄16 49 15⁄8 41 23⁄16 56 43⁄4 121 3.9 22 11⁄4 x 11⁄4 x 1⁄2 32 x 32 x 15 300 20./mm V In.7 1 25 13⁄8 35 15⁄8 41 11⁄4 32 113⁄16 46 41⁄4 108 2.0 1.7 300 20.5 21⁄2 x 21⁄2 x 3⁄4 65 x 65 x 20 175 12. fiG./mm Approx.7 ⁄8 ⁄8 13⁄8 35 17⁄16 37 11⁄16 27 111⁄16 43 41⁄4 108 1.1 2 x 2 x 1⁄2 50 x 50 x 15 175 12.1 250 17.2 2. Wt. Ea. Wt.5 2x2x1 50 x 50 x 25 175 12.11 141 ./DN(mm) Max.7 13⁄8 35 17⁄16 37 11⁄16 27 111⁄16 43 41⁄4 108 1.7 300 20./mm V In. 7106 .7 11⁄4 32 13⁄8 35 13⁄4 44 13⁄8 35 115⁄16 49 43⁄8 111 2. ** “T” .9 0.7 20.2 1.6 1.Reducing Tee (Sock-It ® x Sock-It® x NPT) FIGurE 7106 SocK-It® rEducInG tEE (S x S x nPt) Nominal Size In.2 1.4 1 ⁄4 x 1 x ⁄4 32 x 25 x 20 32 x 25 x 25 300 300 22 22 ⁄8 ⁄8 1 ⁄8 35 35 35 35 35 35 35 35 1 ⁄16 37 37 40 40 40 44 44 44 1 ⁄4 32 32 35 35 35 41 41 41 1 ⁄16 46 46 49 49 49 56 56 56 2.1 1.com GL-6.7 20.Outlet take-out dimension.anvilintl.1 11⁄2 38 13⁄8 35 21⁄8 54 115⁄16 49 27⁄16 62 43⁄4 121 5.7 20.1 2.7 1 25 13⁄8 35 15⁄8 41 11⁄4 32 113⁄16 46 41⁄4 108 2.9 0.7 12. 38 81⁄8 206 111⁄8 283 2 51 /4 x 3 /4 x 3 80 110 100 150 7. Ea. Any Gruvlok gasket material may be utilized in the 7400SS coupling for a broad array of applications. GASKET TYPE: Standard C Style Flush Gap (1 1⁄4" – 8") LUBRICATION: Standard Gruvlok Gruvlok XtremeTM (Do Not use with Grade “L”) FiGURe 7400ss .375 60.7 2.6 0. hydraulic fluids. 142 www.79 31⁄8 79 45⁄8 117 13⁄4 44 15 21 20 27 1./mm In.0 16.625 168.89 0-1⁄32 0-0.1 1.3 275 19.067 71.480 42. In.0 M12 x 70 6 150 6. Size Pressure† Load† Separation X Min. hot air and some high temperature chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. with Type 316 Grade 8M stainless steel heavy hex nuts conforming to ASTM A 194.78 0-1⁄32 0-0.D. alkalies solutions. halogenated hydrocarbons and lubricants.RiGidlite stainless steel CoUPlinG O.0 300 20.1 1. NOT FOR USE IN HOT WATER OR HOT AIR.4 2.79 45⁄8 117 65⁄8 168 13⁄4 44 50 68 60 80 3.948 8. oilfree air and many chemical services. The standard material is ASTM A 743 CF8M (Type 316) cast stainless steel which is ideal for corrosive environments. Contact an Anvil Representative for more information.900 48. air with oil vapors and vegetable and mineral oils.7 M10 x 57 3 11⁄2 40 CAUTION: Contact your local Anvil representative for corrosive application environments. † Ratings apply when used with Schedule 40 ASTM A 312 Type 304 stainless steel pipe for all sizes.660 42. * All bolts are hex head design Type 316 Grade B8M Class 1 stainless steel to ASTM A 193. Grade “L” Silicone (Red color code) -40°F to 350°F (Service Temperature Range)(-40°C to 177°C) Recommended for dry.771 21.1 275 19. Torque Wk.7 1.79 35⁄8 92 53⁄8 137 13⁄4 45 15 21 20 27 2.91 0-1⁄32 0-0. Nuts and bolts are zinc plated to prevent common thread galling.anvilintl.625 219.3 1.0 9.7 851 3.8 3./mm In. diluted acids./mm Max. petroleum oils.12 .4 M12 x 70 1 4 100 4. Y Z Nominal Size In./Kg X 11⁄4 32 1.2 6. PSI/bar Lbs.3 300 20. Type 316 per ASTM A 193 Grade B8M class 1 and heavy hex stainless steel nuts.7 1.22 0-3⁄32 0-2.7 4.7 0.9 300 20.329 5./N-m Lbs.8 M10 x 57 3 2 50 2.84 0-1⁄32 0-0./mm Ft.stainless steel method FIG.0 M10 x 57 3 21⁄2 65 2. End Pipe End Wt.47 0-3⁄32 0-2. HOUSING: Cast Stainless Steel (Type 316) .3 300 20.17 0-3⁄32 0-2./kN In.ASTM A 743 CF8M GASKETS: Materials Properties as designated in accordance with ASTM D 2000 Grade “E” EPDM (Green color code) NSF 61 Certified -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service.500 114.66 0-1⁄32 0-0.886 12.79 27⁄8 73 41⁄8 105 13⁄4 44 2 2 2 2 2 2 2 2 3 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄8 x 21⁄4 ⁄2 x 23⁄4 ⁄2 x 23⁄4 3 15 21 20 27 1. 1. Refer to ratings chart for additional data.com GL-7. The 7400SS is provided with ASTM A 193 B8M bolts and ASTM A 194 Grade 8M nuts.7 649 2. Type 316 per ASTM A 194 Grade 8M class 1. Max. Max. MATERIAL SPECIFICATIONS STAINLESS STEEL BOLTS & NUTS: Hex head stainless steel bolts.38 6 152 73⁄4 197 17⁄8 48 50 68 60 80 4. No coatings or zinc options. Use of suitable anti-galling thread compound is recommended.0 M20 x 76 Range of Pipe End Separation values are for roll grooved pipe and may be doubled for cut groove pipe./mm In. 7400SS Rigidlite® Coupling The Gruvlok Figure 7400SS coupling is available in 1 1⁄4" – 8" sizes.0 M10 x 57 1 3 80 3. Grade “T” Nitrile (Orange color code) -20°F to 180°F (Service Temperature Range)(-29°C to 82°C) Recommended for petroleum applications./mm Grade “O” Fluoro-Elastomer (Blue color code) 20°F to 300°F (Service Temperature Range)(-29°C to 149°C) Recommended for high temperature resistance to oxidizing acids.38 103⁄8 264 135⁄8 346 23⁄8 60 80 110 100 150 13. Gasket properties are as designated in accordance with ASTM D 2000. Y Z Qty.3 300 20.5 M20 x 76 3 8 200 8.500 88.79 41⁄8 105 57⁄8 149 13⁄4 44 15 21 20 27 2.-Lbs. Range of Coupling Dimensions Coupling Bolts* Specified Approx.4 300 20./mm In.875 73. StAInLESS StEEL MEtHod Anvil offers two different sets of stainless steel fittings. The Gruvlok Series Fittings have full flow designs formed from type 304SS pipe. The Schedule 10 fittings are fabricated from segmentally welded 316SS unless otherwise noted and are also available as Schedule 40 and/or Type 304SS. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok stainless steel fittinGs GruVLoK couPLInG & FLAnGE WorKInG PrESSurE rAtInGS (PSI) The following are pressure ratings for Gruvlok Stainless Steel Piping Systems. The ratings for Schedule 10S pipe are based upon the use of roll-groover roll sets that have been specifically designed for use on Schedule 10 Stainless Steel pipe. Using roll sets that were designed for roll grooving standard wall pipe may significantly reduce the pressure ratings that can be obtained. The Model 1007/3007 roll groovers require the use of the optional Schedule 10 roll set to groove Schedule 5S and 10S. For grooving Schedule 40S on the Model 1007/3007 roll groovers, the standard steel roll grooving set should be used. GruVLoK couPLInG & FLAnGE WorKInG PrESSurE rAtInGS (PSI) on 304 And 316 StAInLESS StEEL roLL GrooVEd PIPE Nominal Pipe Size In./DN(mm) Pipe O.D. In./mm Nominal Wall Thickness Inches Pipe Schedule Number – Coupling and Flanges Fig. 7000 Lightweight Fig. 7001 Standard Fig. 7003 Hingelok Fig. 7004 HPR Fig. 7010* Reducing PSI Fig. 7012 Flange Fig. 7013 Flange Fig. 7400 Rigidlite Fig. 7401 Rigidlok Fig. 7400SS Coupling 25 1 1.315 33.4 11⁄4 32 1.660 42.4 11⁄2 40 1.900 48.3 50 2 2.375 60.3 21⁄2 65 2.875 73.0 80 3 3.500 88.9 100 4 5 6 8 4.500 114.3 125 5.563 141.3 150 6.625 168.3 200 8.625 219.1 250 10 12 10.750 273.0 300 12.750 323.9 0.065 0.109 0.133 0.065 0.109 0.140 0.065 0.109 0.145 0.065 0.109 0.154 0.083 0.120 0.203 0.083 0.120 0.216 0.083 0.120 0.237 0.109 0.134 0.258 0.109 0.134 0.280 0.109 0.148 0.322 0.134 0.165 0.365 0.156 0.180 0.375 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 400 400 500 400 500 500 400 500 500 250 500 500 250 500 500 250 500 500 200 300 500 125 200 300 75 200 300 50 150 300 – – – – – – 400 500 750 400 500 750 400 500 750 325 500 750 325 500 750 325 500 750 250 400 750 200 300 500 125 200 500 75 200 400 50 100 400 75 125 400 – – – – – – 275 300 300 250 300 300 250 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 150 300 – – – – – – – – – – – – – – – 325 500 750 325 500 750 325 500 750 250 400 750 200 300 500 125 200 500 75 200 400 50 100 400 75 125 400 – – – – – – – – – 250 500 500 250 500 500 250 500 500 200 300 500 125 200 300 75 200 300 50 150 300 – – – – – – – – – – – – – – – 250 300 300 250 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 150 300 50 100 300 50 100 300 – – – – – – – – – 275 300 300 275 300 300 275 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 100 300 75 125 300 300 300 300 300 300 300 300 300 300 250 300 300 250 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 150 300 – – – – – – – – – – – – 400 500 750 325 500 750 325 500 750 325 500 750 250 400 750 200 300 500 125 200 500 75 200 400 50 100 400 75 125 400 – – – 275 300 300 275 300 300 275 300 300 200 300 300 200 300 300 200 300 300 – – – 125 250 275 75 150 275 – – – – – – Notes: 1) Pressure ratings based on ASTM A312 Type 304 stainless steel pipe or equivalent. 2) Failure to use Rollers specifically designed for Stainless Steel Pipe may significantly reduce pressure retention capabilities. 3) Pressure ratings on cut grooved pipe meet or exceed the schedule 40 pressure ratings listed above. For information regarding higher ratings contact Anvil. 4) * For pressure ratings on Figure 7010 Reducing Couplings use larger pipe size. 5) For pressure ratings for the reducing tees, concentric reducers and eccentric reducers, use the rating of the weakest end. 6) Pressure ratings on schedule 10 stainless steel pipe may be increased by using Anvil's 1007/3007 roll groovers with the schedule 10 roller set. Contact Anvil for details. www.anvilintl.com GL-6.11 143 StAInLESS StEEL MEtHod Gruvlok stainless steel fittinGs - type 304 PrESSurE rAtInGS For StAInLESS StEEL PIPE & FIttInGS Schedule 10S pipe are based upon the use of roll-groover roll sets that have been specifically designed for use on Schedule 10S stainless steel pipe. Using roll sets that were designed for roll grooving carbon steel pipe may significantly reduce the pressure ratings that can be obtained. Consult Gruvlok for applications that involve roll grooving 10" or larger stainless steel pipe or that involves Schedule 5S stainless steel pipe. SErIES SS FIttInG PrESSurE rAtInGS Sizes Pressure (psi) 11⁄4" 11⁄2" 500 500 2" 500 21⁄2" 500 3" 500 4" 500 6" 400 8" 250 10" 100 12" 200 Gruvlok Series Stainless Steel Fittings are full flow design with ends grooved to Gruvlok specifications. The Series standard material is formed from Type 304 Stainless Steel. The Series Fittings are annealed after forming and grooving to provide increased corrosion resistance. Gruvlok Series Stainless Steel 45˚ and 90˚ elbows and tees have compact centerto-end dimensions which make installation quick and easy with the Gruvlok Figure 7400SS Coupling, or other Gruvlok products. fiG. 7050-ss04 fiG. 7051-ss04 fiG. 7060-ss04 fiG. 7074-ss04 90° Stainless Steel Elbow Type 304 45° Stainless Steel Elbow Type 304 E C O .D . to Stainless Steel Tees Type 304 Stainless Steel Caps Type 304 O.D. C to E C to E O.D. O.D. C to E E to E FIGurE A7050SS 90° StAInLESS StEEL ELBoW Nominal Size In./DN(mm) FIGurE A7051SS 45° StAInLESS StEEL ELBoW Nominal Size In./DN(mm) FIGurE A7060SS StAInLESS StEEL tEE Nominal Size In./DN(mm) FIGurE A7074SS StAInLESS StEEL cAP Nominal Size In./DN(mm) Center to End* In./mm Approx. Wt. Ea. Lbs./Kg Center to End* In./mm Approx. Wt. Ea. Lbs./Kg Center to End* In./mm Approx. Wt. Ea. Lbs./Kg Center to End* In./mm Approx. Wt. Ea. Lbs./Kg 11⁄4 11⁄2 40 50 65 80 100 150 200 250 300 32 71.44 76.20 93.66 109.54 128.59 160.34 228.60 304.80 381.00 457.20 213⁄16 3 0.8 1.0 1.3 1.8 2.9 4.6 11.2 22.7 35.3 56.9 25.8 16.0 10.3 5.1 2.1 1.3 0.8 0.6 0.5 0.4 11⁄4 11⁄2 40 50 32 44.45 47.63 53.98 60.33 71.44 84.14 114.30 149.23 180.98 219.08 13⁄4 17⁄8 0.4 0.5 0.7 0.9 1.5 2.4 6.0 11.7 17.6 27.6 12.5 8.0 5.3 2.7 1.1 0.7 0.4 0.3 0.2 0.2 11⁄4 11⁄2 40 50 65 80 100 150 200 250 300 32 69.85 74.61 80.96 93.66 101.60 125.41 165.10 204.79 241.30 279.40 23⁄4 1.1 1.3 3.2 4.4 5.8 8.6 18.5 33.4 35.3 52.7 23.9 16.0 15.1 8.4 3.9 2.6 2.0 1.5 0.6 0.5 11⁄4 11⁄2 40 50 65 80 100 150 200 250 300 32 215⁄16 33⁄16 44.45 44.45 50.80 55.56 65.09 74.61 90.49 101.60 127.00 152.40 13⁄4 13⁄4 2 0.4 0.4 0.4 0.9 1.1 1.5 3.1 6.6 9.9 15.2 6.9 4.5 3.0 1.4 0.7 0.5 0.4 0.2 0.2 0.2 2 311⁄16 45⁄16 2 21/8 23⁄8 2 2 21⁄2 3 4 6 8 21⁄2 65 80 100 150 200 250 300 21⁄2 3 4 6 8 311⁄16 4 21⁄2 3 4 6 8 23⁄16 51⁄16 3 4 6 8 213⁄16 35/16 41/2 57/8 71/8 29/16 65/16 9 415/16 61⁄2 215/16 39⁄16 4 12 15 18 81⁄16 91/2 11 10 12 10 12 10 12 10 12 5 6 85/8 Notes: 1) *Dimensions may differ from those shown above. Contact an Anvil Representative for more information. 2) For Series 304 SS refer to the pressure ratings chart above. 144 www.anvilintl.com GL-6.11 StAInLESS StEEL MEtHod Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok stainless steel fittinGs - type 304 fiG. 7061-ss04 fiG. 7072-ss04 Stainless Steel Reducing Tees Type 304 Stainless Steel Concentric Reducers Type 304 O.D. C to E O.D. O.D. Red. (Branch) C to E (Run) E to E FIGurE A7061SS StAInLESS StEEL rEducInG tEE Nominal Size In./DN(mm) FIGurE A7072SS StAInLESS StEEL concEntrIc rEducEr Nominal Size In./DN(mm) Center to Center to End (Run) End (Branch) In./mm In./mm Approx. Wt. Ea. Lbs./Kg End to End* In./mm Approx. Wt. Ea. Lbs./Kg 11/2 x 11/4 40 x 32 215⁄16 74.61 23⁄4 69.85 1.3 0.6 11⁄2 x 11⁄4 40 x 32 33⁄4 95.25 0.4 0.2 2 x 11/4 50 x 32 33⁄16 80.96 215⁄16 74.61 1.8 0.8 2 x 11⁄4 50 x 32 41⁄8 104.78 0.7 0.3 2 x 11/2 50 x 40 33⁄16 80.96 31⁄16 77.79 1.8 0.8 2 x 11⁄2 50 x 40 41⁄8 104.78 0.7 0.3 21/2 x 11/2 65 x 40 311⁄16 93.66 35⁄16 84.14 2.7 1.2 21⁄2 x 11⁄2 65 x 40 47⁄16 112.71 1.1 0.5 21/2 x 2 65 x 50 311⁄16 93.66 39⁄16 90.49 2.7 1.2 21⁄2 x 2 65 x 50 47⁄16 112.71 1.1 0.5 3 x 11/2 80 x 40 4 101.60 39⁄16 90.49 3.1 1.4 3 x 11⁄2 80 x 40 43⁄4 120.65 1.3 0.6 3x2 80 x 50 4 101.60 311⁄16 93.66 5.1 2.3 3x2 80 x 50 43⁄4 120.65 1.3 0.6 3 x 21/2 80 x 65 4 101.60 37⁄8 98.43 5.4 2.4 3 x 21⁄2 80 x 65 43⁄4 120.65 1.3 0.6 4x2 100 x 50 415⁄16 125.41 45⁄16 109.54 8.0 3.6 4x2 100 x 50 55⁄16 134.94 1.8 0.8 4 x 21/2 100 x 65 415⁄16 125.41 45⁄8 117.48 5.3 2.4 4 x 21⁄2 100 x 65 55⁄16 134.94 1.8 0.8 4x3 100 x 80 415⁄16 125.41 43⁄4 120.65 8.6 3.9 4x3 100 x 80 55⁄16 134.94 2.0 0.9 6x3 150 x 80 61⁄2 165.10 513⁄16 147.64 16.8 7.6 6x3 150 x 80 63⁄4 171.45 3.8 1.7 6x4 150 x 100 61⁄8 155.58 6 152.40 16.8 7.6 6x4 150 x 100 63⁄4 171.45 4.0 1.8 8x4 200 x 100 81⁄16 204.79 73⁄16 182.56 29.7 13.4 8x4 200 x 100 79⁄16 192.09 6.6 3.0 8x6 200 x 150 81⁄16 204.79 711⁄16 195.26 33.4 15.1 8x6 200 x 150 79⁄16 192.09 7.3 3.3 10 x 6 250 x 150 91⁄2 241.30 87⁄8 255.43 21.6 9.8 10 x 6 250 x 150 811⁄16 220.66 9.7 4.4 10 x 8 250 x 200 91⁄2 241.30 91⁄16 230.19 32.2 14.6 10 x 8 250 x 200 811⁄16 220.66 10.6 4.8 12 x 8 300 x 200 11 279.40 101⁄16 255.59 47.2 21.4 12 x 8 300 x 200 97⁄16 239.71 15.0 6.8 12 x 10 300 x 250 11 279.40 109⁄16 268.29 49.2 22.3 12 x 10 300 x 250 97⁄16 239.71 15.9 7.2 Notes: 1) *Dimensions may differ from those shown above. Contact an Anvil Representative for more information. 2) For Series 304 SS pressure ratings refer to the chart on page 144. 3) The pressure rating for the reducing tees and concentric reducers is based upon the rating of the weakest end. www.anvilintl.com GL-6.11 145 StAInLESS StEEL MEtHod Gruvlok stainless steel fittinGs - type 316 Gruvlok Schedule 10 Stainless Steel Fittings are segmentally welded with ends grooved to Gruvlok specifications. The standard material is 316 Stainless Steel unless otherwise noted with 304SS and/or Schedule 40 optional. Installation is quick and easy with the Gruvlok Figure 7400SS Coupling, or other Gruvlok product. fiG. 7050ss 90° Stainless Steel Elbow Type 316 fiG. 7051ss 45° Stainless Steel Elbow Type 316 fiG. 7060ss Stainless Steel Tees Type 316 fiG. 7074ss Stainless Steel Caps Type 316 O.D. C to E O.D. C to E O.D. O.D. E to E FIGurE 7074SS StAInLESS StEEL cAP Nominal Size In./DN(mm) C to E FIGurE 7050SS 90° StAInLESS StEEL ELBoW Nominal Size In./DN(mm) FIGurE 7051SS 45° StAInLESS StEEL ELBoW Nominal Size In./DN(mm) C to E FIGurE 7060SS StAInLESS StEEL tEE Nominal Size In./DN(mm) Center to End* In./mm Approx. Wt. Ea. Lbs./Kg Center to End* In./mm Approx. Wt. Ea. Lbs./Kg Center to End* In./mm Approx. Wt. Ea. Lbs./Kg Center to End* In./mm Approx. Wt. Ea. Lbs./Kg 11⁄4 11⁄2 40 50 65 80 100 150 200 250 300 32 35⁄8 108 111 146 41⁄4 98 1.2 1.4 2.3 3.3 4.6 7.9 17.0 29.4 41.8 46.5 21.1 18.9 13.4 7.7 3.6 2.1 1.5 1.0 0.6 0.5 11⁄4 11⁄2 40 50 32 21⁄2 21⁄2 21⁄2 64 76 86 64 64 0.7 0.9 1.5 1.9 3.3 5.4 11.2 19.8 21.0 23.0 10.4 9.5 9.0 5.1 2.4 1.5 0.9 0.7 0.4 0.3 11⁄4 11⁄2 40 50 65 80 100 150 200 250 300 32 23⁄4 23⁄4 31⁄4 33⁄4 41/4 108 127 165 197 229 254 95 83 70 70 1.5 1.8 2.4 4.0 5.8 10.3 25.7 41.1 36.0 48.4 22.0 16.3 18.6 11.7 4.7 2.6 1.8 1.1 0.8 0.7 11⁄4 11⁄2 40 50 65 80 100 150 200 250 300 32 15⁄8 15⁄8 15⁄8 13⁄4 13⁄4 13⁄4 17⁄8 21/4 21/4 21/4 57 57 57 48 45 45 45 41 41 41 0.4 0.5 0.8 1.1 1.6 2.8 3.7 8.8 12.1 17.3 7.8 5.5 4.0 1.7 1.3 0.7 0.5 0.4 0.2 0.2 2 43⁄8 53⁄4 2 2 2 21⁄2 3 4 21⁄2 65 80 100 150 200 250 300 3 21⁄2 3 4 6 8 21⁄2 3 4 6 8 71/2 103/4 273 381 457 533 191 149 57⁄8 3 4 6 33⁄8 102 140 184 4 5 6 8 51/2 71/4 81/2 216 254 61⁄2 73⁄4 9 15 18 21 8 10 12 10 12 10 12 10 12 10 10 Notes: 1) *Dimensions may differ from those shown above. Contact an Anvil Representative for more information. 2) Fabricated fittings weights are based on Schedule 10 pipe. 3) Fabricated Schedule 10, 316SS and Schedule 40 Center to End dimensions are the same. 4) The pressure rating for the Gruvlok Schedule 10 Stainless Steel Fittings are equal to the pressure rating of the coupling used on Schedule 10 pipe as shown in the Working Pressure Ratings Chart for Stainless Steel Roll Grooved Pipe on page 143. 146 www.anvilintl.com GL-6.11 StAInLESS StEEL MEtHod fiG. 7061ss Stainless Steel Reducing Tees Type 316 fiG. 7072ss Stainless Steel Concentric Reducers – Type 316 fiG. 7073ss Stainless Steel Eccentric Reducers – Type 316 fiG. 7084ss Groove x Class 150 Stainless Steel Flange Adapter Type 304 E to E E to E O.D. C to E C to E E to E O.D. O.D. O.D. FIGurE 7061SS StAInLESS StEEL rEducInG tEE Nominal Size In./DN(mm) FIGurE 7072SS StAInLESS StEEL concEntrIc rEducEr Nominal Size In./DN(mm) FIGurE 7073SS StAInLESS StEEL EccEntrIc rEducEr Nominal Size In./DN(mm) FIGurE 7084SS StAInLESS StEEL FLAnGE AdAPtEr Nominal Size In./DN(mm) Center to End* In./mm Approx. Wt. Ea. Lbs./Kg End to End* In./mm Approx. Wt. Ea. Lbs./Kg End to End* In./mm Approx. Wt. Ea. Lbs./Kg End to End* In./mm Approx. Wt. Ea. Lbs./Kg 11⁄2 x 11/2 x 3/4 1 ⁄2 x 1 /2 x 1 1 1 40 x 40 x 20 40 x 40 x 25 40 x 40 x 32 50 x 50 x 20 50 x 50 x 25 50 x 50 x 32 23⁄4 2 ⁄4 3 70 70 70 83 1 1 1.3 1.4 1.5 2.0 2.1 2.3 2.5 2.8 3.0 3.5 3.8 4.0 4.1 4.2 4.3 4.5 4.8 5.8 5.9 6.0 14.0 14.5 29.6 31.1 14.1 13.5 6.6 6.4 2.7 2.7 2.6 2.2 2.0 1.9 1.9 1.9 1.8 1.7 1.6 1.4 1.3 1.1 1.0 1.0 0.9 0.7 0.6 0.6 11⁄2 x 1 40 x 25 61⁄2 165 0.7 0.3 11⁄2 x 1 40 x 25 81⁄2 216 1.7 0.8 2 50 31/8 79.38 5.7 2.6 11⁄2 x 11/4 40 x 32 61⁄2 165 0.7 0.3 11⁄2 x 11/4 40 x 32 81⁄2 216 4.5 2.0 21⁄2 65 33⁄8 85.73 8.6 3.9 11⁄2 x 11/2 x 11/4 2 x 2 x 3/4 2x2x1 1 23⁄4 31⁄4 3 ⁄4 3 ⁄4 31⁄4 33⁄4 33⁄4 3 ⁄4 3 3 2x1 50 x 25 7 178 0.9 0.4 2x1 50 x 25 9 229 2.2 1.0 3 80 33⁄8 85.73 9.7 4.4 2 x 11/4 50 x 32 7 178 0.9 0.4 2 x 11/4 50 x 32 9 229 2.4 1.1 4 100 39/16 90.49 14.6 6.6 2 x 2 x 1 /4 2 x 2 x 11/2 83 83 83 95 95 95 95 2 x 11/2 50 x 40 7 178 1.2 0.5 2 x 11/2 50 x 40 9 229 2.5 1.1 5 125 33⁄4 95.25 17.5 7.9 21⁄2 x 21/2 x 3/4 21⁄2 x 21/2 x 1 2 ⁄2 x 2 /2 x 1 /2 1 1 1 50 x 50 x 40 65 x 65 x 20 65 x 65 x 25 65 x 65 x 40 1 1 21⁄2 x 1 65 x 25 71⁄2 191 1.1 0.5 21⁄2 x 1 65 x 25 91⁄2 241 3.2 1.5 6 150 315⁄16 100.01 19.4 8.8 21⁄2 x 11/2 65 x 40 71⁄2 191 1.2 0.5 21⁄2 x 11/2 65 x 40 91⁄2 241 3.6 1.6 8 200 41/2 114.30 32.9 14.9 21⁄2 x 2 65 x 50 71⁄2 191 1.2 0.5 21⁄2 x 2 65 x 50 91⁄2 241 4.0 1.8 10 250 43⁄4 120.65 45.0 20.4 2 ⁄2 x 2 /2 x 2 65 x 65 x 50 80 x 80 x 20 80 x 80 x 25 80 x 80 x 32 80 x 80 x 40 80 x 80 x 50 80 x 80 x 65 100 x 100 x 50 100 x 100 x 65 100 x 100 x 80 150 x 150 x 80 150 x 150 x 100 200 x 200 x 100 200 x 200 x 150 3 ⁄4 108 108 108 108 108 108 127 127 127 165 165 197 197 3x1 80 x 25 71⁄2 191 1.8 0.8 3x1 80 x 25 91⁄2 241 4.0 1.8 12 300 43⁄4 120.65 70.8 32.1 3 x 3 x 3/4 3 x 3x 1 41⁄4 41⁄4 41⁄4 41⁄4 4 ⁄4 1 1 3 x 11/4 80 x 32 71⁄2 191 1.8 0.8 3 x 11/4 80 x 32 91⁄2 241 4.3 2.0 3 x 11/2 80 x 40 71⁄2 191 1.9 0.9 3 x 11/2 80 x 40 91⁄2 241 4.5 0.9 3 x 3 x 11/4 3 x 3 x 11/2 3x3x2 1 4x2 100 x 50 8 203 2.9 1.3 4x2 100 x 50 10 254 6.7 3.0 4 x 21/2 100 x 65 8 203 3.1 1.4 4 x 21/2 100 x 65 10 254 7.3 3.3 3 x 3 x 2 /2 4x4x2 4 ⁄4 5 5 5 4x 3 100 x 80 8 203 3.1 1.4 4x 3 100 x 80 10 254 7.9 3.6 6 x 21/2 150 x 65 91/2 241 7.1 3.2 6 x 21/2 150 x 65 111/2 292 12.8 5.8 4 x 4 x 21/2 4x4x3 6x6x3 6x6x4 8x8x4 8x8x6 6x3 150 x 80 91/2 241 7.0 3.2 6x3 150 x 80 111/2 292 13.6 6.2 61⁄2 6 ⁄2 1 3 6x4 150 x 100 91/2 241 7.0 3.2 6x4 150 x 100 111/2 292 14.9 6.8 8x4 200 x 100 10 254 11.7 5.3 8x4 200 x 100 12 305 19.7 8.9 7 ⁄4 73⁄4 8x6 200 x 150 10 254 11.5 5.2 8x6 200 x 150 12 305 23.2 10.5 Notes: 1) *Dimensions may differ from those shown above. Contact an Anvil Representative for more information. 2) Fabricated fittings weights are based on Schedule 10 pipe. 3) Fabricated Schedule 10, 316SS and Schedule 40 Center to End dimensions are the same. 4) The pressure rating for the Gruvlok Schedule 10 Stainless Steel Fittings are equal to the pressure rating of the coupling used on Schedule 10 pipe as shown in the Working Pressure Ratings Chart for Stainless Steel Roll Grooved Pipe on page 143. 5) The pressure rating for the reducing tees, concentric reducers and eccentric reducers should be based upon the dimension of the weakest end. www.anvilintl.com GL-6.11 147 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok stainless steel fittinGs - type 316 8" . 10S. model 3007 roll Groovers B.roLL GrooVErS model 1007 & 3007 Roll Groovers A. one and one-half horsepower electric motor drive with foot switch.12" steel pipe. 148 www. Shipped in closed wood crate that can be used for storage or rental tool return.Roll Groover complete with groove and drive rolls for 2" . Two stage hydraulic hand pump.12" rolls stored in box. and 5"-8" CTS Depth Gauge.S. 2"-4" CTS Depth Gauge. Complete set-up and operating instructions. Required Ridgid 300 Power Drive not included. two stage hydraulic hand pump. Gruvlok roll grooving technology is protected by U. Patents 5450738.12" rolls stored in box. 5570603. model 1007 roll Groovers A. Shipping Weight: 620 lbs. 1007 STANDARD EQUIPMENT . 15 amp. 40S Rolls: Consisting of 2"-6" and 8"-12" roll sets. 3007 STANDARD EQUIPMENT – Roll Groover complete with groove and drive rolls for 2" . CTS Copper System Option: • 2"-8" CTS Copper System Grooving Rolls. and three depth gauges covering the range of 2"-12" pipe are mounted on the tool.6" rolls on tool. 5778715 and others pending. single phase electrical panel with motor is available for the 1007 Roll Groover.6" rolls on tool.12 .12" steel pipe. Steel/CTS Dual Guide Roll Assembly. Shipped in closed wood crate that can be used for storage or rental tool return. Steel/CTS Dual Guide Roll Assembly. Other: • Optional 230 volt. mounting base with footed support legs.com GL-7. Complete set-up and operating instructions. oPtIonAL EQuIPMEnt Steel Pipe: • 2"-12" Schedule 10. mounting base with footed support legs for direct attachment to your Ridgid® 300 Power Drive. Shipping Weight: 330 lbs. 60Hz. and three depth gauges covering the range of 2" through 12" pipe are mounted on the tool. • 14"-16" Steel Grooving Rolls (Model 1007 only). 2" . 40. 2" . 8" .anvilintl. com GL-7. control for grooving carbon and stainless piping. universal diameter gauge must be utilized. 10S. hands-clear operation. 2" thru 12" Schedule 10S and 40S Stainless Steel and 2" thru 8" copper tube type K.12" – Sch. L. • WIDE GROOVING RANGE— 2" thru 16" standard wall & schedule 10 steel pipe. Two-stage design saves time engaging pipe while providing smooth application of optimum grooving force with reduced operator effort. • EASE OF OPERATION— High grooving forces obtained through use of larger capability ram requires less pump effort.) Pipe Size (In./DN(mm)) – Sch. 40 Steel Schedule 10S. • FOOT SWITCH POWER APPLICATION • OPERATOR SAFE DESIGN www. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories model 1007 & 3007 c . 40 Copper: 2" . The shortest roll groove nipple capability in the industry.21⁄2” – Type M 3" .roLL GrooVErS Roll Groovers Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. M. • HANDS CLEAR GROOVING OF PIPE AND NIPPLES— Enhanced operator safety provided by outboard guide roll assembly. REPEATABLE-GROOVE DIAMETER CONTROL— Simplified direct action design provides positive. n/a n/a Std. The times shown are average times from the start of rotation of the pipe in the grooving rolls to completed groove. L. • FAST GROOVING TIMES— Large capacity two-stage pump. (2) Minimum wall thickness for each pipe materials and size is: Steel: 2" . n/a n/a (1) All wall thickness shown are the maximum wall thickness for the indicated pipe material. • PIPE LENGTHS—20’ random schedule 40 (standard wall) to 5" groove by groove nipples.8" – Type DWV NOTE: Some sizes may require optional equipment.Groover times ModEL 1007 & ModEL 3007 StEEL PIPE GrooVInG tIMES (MIn: SEc. 40S K. For grooving copper. 14" & 16" Standard Wall Stainless Steel: 2" . Wall) Steel Pipe 2 50 21⁄2 65 3 80 4 100 5 125 6 150 8 200 10 250 12 300 14 350 16 400 0:20 0:20 0:25 0:30 1:00 1:20 1:35 1:50 2:20 2:40 3:00 This chart shows approximate grooving times with the groover setup for the proper size and groove diameter and the pipe properly positioned on the groover.anvilintl. EASY SETUP AND ROLL CHANGE • RUGGED DESIGN REQUIRES zERO MAINTENANCE— Sealed bearings eliminate need for periodic maintenance. • QUICK. 10. • BETTER CONTROL OF PIPE FLARE— Outboard guide roll assembly registers pipe for proper orientation.12" – Sch. • USER FRIENDLY DESIGN— Pump location is adjustable for operator comfort and safety. repeatable.Groover capability GrooVEr cAPABILItY Pipe Material In. and DWV. • ACCURATE. (3) Contact an Anvil Representative for information on grooving alternate materials d .12 149 . DN(mm) 2 50 21⁄2 65 3 80 4 100 Pipe Size/Wall Thickness (Schedule) 5 125 6 150 8 200 10 250 12 300 14 350 16 400 Steel Stainless Copper NOTES: Schedule 10. M & DWV n/a n/a Std. 40 (Std. 10 2" thru 6" Schedule 10S and 40S Stainless Steel Pipe. Low cost.6" stainless steel. Gruvlok roll grooving technology is protected by U. 150 www. Standard with each machine is the patented Gruvlok hands free nipple guide system. M. the Model 3006 Roll Groover follows the quality Gruvlok tradition started with 1007/3007 models and takes the future of roll grooving one step further. and 2" thru 12" Sch.S.219” wall). and reliable. Patents 5450738. • BETTER CONTROL OF PIPE FLARE— Outboard guide roll assembly registers pipe for proper orientation. • USER FRIENDLY DESIGN— Pump has a special reduced height handle and adjustable location for operator comfort and safety.188" Wall).com GL-7.anvilintl. user friendly. This machine is also compatible with the CTS Copper System for accurate and repeatable grooving of tube as small as 2" in diameter.12 . repeatable control for grooving carbon and stainless piping. • QUICK. 12" (. REPEATABLE GROOVE DIAMETER CONTROL— Simplified direct action provided positive.roLL GrooVErS model 3006 Roll Groover The Gruvlok Model 3006 roll groover features a low maintenance quick roll change out design with the capability to groove 2" . 10" (. • WIDE GROOVING RANGE— 2" thru 8" Schedule 40 (standard wall) steel pipe. The shortest roll groove nipple capability in the industry: hands clear • HANDS-CLEAR GROOVING OF PIPE AND NIPPLES— Enhanced operator safety provided by outboard guide roll assembly • ACCURATE. 5570603. • EASE OF OPERATION— High grooving forces obtained though use of large capacity ram requires less pump effort. and DWV. • PIPE LENGTHS— 20' random Schedule 40 (standard wall) to 5" groove by groove nipples. lightweight. EASY SETUP AND ROLL CHANGE • RUGGED DESIGN REQUIRES MINIMAL MAINTENANCE— Only periodic application of grease via grease fittings required. L.12" steel pipe. 5778715 and others pending. as well as 2" . and 2" thru 8" copper type K. universal diameter gauge must be utilized. This one of a kind nipple guide system allows for the shortest nipple grooving in the business and is hands free for increased operator safety. A special hydraulic pump with a reduced height handle and pivoting location allow each operator to customize the machine for maximum comfort while grooving. For grooving copper. Complete with comprehensive setup. hydraulic pump with pressure gauge. Groover capability GrooVEr cAPABILItY Pipe Material In. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories model 3006 technical data – model 3006 StAndArd EQuIPMEnt: Roll Groover complete with Adjustable Support Leg Assembly and roller sets for grooving 2"-6" and 8"-12" steel pipe. CTS Copper System Option: • Consisting of 2"-8" roll set. Groover times ModEL 3006 StEEL PIPE GrooVInG tIMES (MIn: SEc.anvilintl. and two depth adjustment gauges./DN(mm))/Max Steel Pipe Wall Thickness 2 50 21⁄2 65 3 80 4 100 6 150 8 200 10 250 12 300 0:20 0:20 0:25 0:30 1:20 1:55 1:40 1:20 GROOVING TIMES: This chart shows approximate grooving times with the groover set-up for the proper size and groove diameter and the pipe properly positioned on the groover. Required Ridgid® 300 Power Drive not included.com GL-7. This unit is designed for direct attachment to your Ridgid® 300 Power Drive. operating and troubleshooting instructions. 40 Schedule 10S.188" n/a n/a 0. Steel/CTS Dual Guide Roll Assembly. The times shown are average times from the start of rotation of the pipe in the grooving rolls to completed groove. and 8" CTS Depth Gauge.roLL GrooVErS Roll Groover Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Shipped in a reusable wooden storage crate. 21⁄2" – Type M 3" .12 151 . M & DWV n/a 0. L. Approximate shipping weight: 225 pounds.) Pipe Size (In.8" – Type DWV Schedule 10. Advanced Copper Method Guide Roll Assembly. 10 Stainless Steel: 2" . 40S Copper: 2". oPtIonAL EQuIPMEnt: Advanced Copper Method (IPS Copper) Option: • Consisting of 2"-6" Advanced Copper Method roll set.6" Sch. www.219" n/a n/a (3) Please contact an Anvil Representative for more information on grooving alternate materials & wall thickness. (2) Minimum wall thickness for each pipe materials and size is: Steel: All sizes – Sch. • 2"-6" Universal Diameter Gauge. and a 2"-6" Universal Diameter Gauge.2 3 80 4 100 5 125 6 150 8 200 10 250 12 300 65 Steel Stainless Steel CTS Copper System NOTES: (1) All wall thickness shown are the maximum wall thickness for the indicated pipe material. 40S K. 10S. 2"-6" CTS Depth Gauge. DN(mm) 2 50 2 ⁄2 1 Pipe Size/Wall Thickness (Schedule)1. ............ 7012 Gruvlok Flange (14" ...... 7003 HingelokTM Coupling . 7001 Standard Coupling ...155 FIG............ 153 FIG......175-178 Series GBV-S & GBV-T Circuit Balancing Valves ........158 FIG.......162-163 FIG....com GL-7.. The nuts must be tightened alternately and evenly until fully tightened.......... 7307 HDPE Transition Coupling .. Installation & Assembly table of contents FIG.......................... joint leakage and pipe joint separation............................ Thorough lubrication of the external surface of the gasket is essential to prevent pinching and possible damage to the gasket.............. 152 www.24") ............ 7401-2 2-Piece Large Dia....... Specified Bolt Torque * Ft....... battery strength and operational variations.......... Pipe joint separation may result in significant property damage and serious injury....... notE: Specified torques are to be used unless otherwise noted on Product Installation Instructions........ AF21-GG.... 157 FIG... 154 FIG... 7001-2 & FIG......................................12") ........ 167 FIG.................170 FIG.... 7012 Gruvlok Flange (2" ......... MEtrIc SPEcIFIEd BoLt torQuE Bolt Size mm Wrench Size In... Caution: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply......160 FIG......12 ..... See Gruvlok Lubricants in the Technical Data section of the Gruvlok catalog for additional important information..................... 7004 High Pressure Coupling ......... 7045 & FIG.... Couplings . 7011 Standard Coupling..6° C) use Gruvlok XtremeTM Lubricant and lubricate all gasket surfaces... 7005 Roughneck® Coupling...... internal and external........ 6400 Rigid Coupling..... 172 FIG.....................171 FIG. 7401 Rigidlok® Coupling .......... Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation.......... 179-181 FIG........... Check pipe ends for proper groove dimensions and assure that the pipe ends are free of indentations and projections which would prevent proper sealing....................... AnSI SPEcIFIEd BoLt torQuE Bolt Size In.. Under torquing the bolts may result in lower pressure retention capabilities.................... 7400 Rigidlite® Coupling.............. ... SPEcIFIEd BoLt torQuE Specified bolt torque is for the oval neck track bolts used on Gruvlok® couplings and flanges............ 173 Gruvlok Sock-It® Fitting ................ 7010 Reducing Coupling ..anvilintl........... For temperatures above 150° F (65.....164 FIG..........................................165 FIG.............-Lbs Wrench Size mm Specified Bolt Torque * N-m ⁄8 1 ⁄2 5 ⁄8 3 ⁄4 7 ⁄8 1 11⁄8 11⁄4 3 ⁄16 7 ⁄8 11⁄16 11⁄4 17⁄16 15⁄8 113⁄16 2 11 30-45 80-100 100-130 130-180 180-220 200-250 225-275 250-300 M10 M12 M16 M20 M22 M24 16 22 24 30 34 36 40-60 110-150 135-175 175-245 245-300 270-340 * Non-lubricated bolt torques............................... 7305 HDPE Coupling .... 7004 High Pressure Coupling with EG Gasket .... 7000 Lightweight Flexible Coupling ..156 FIG.......... ALWAYS USE A GRUVLOK® LUBRICANT FOR PROPER COUPLING ASSEMBLY.. lower bend load capabilities.....................166 FIG... 7044 Branch Outlet.............169 FIG...................GruVLoK InStALLAtIon And ASSEMBLY couplinG installation & assembly The instructions are based on pipe grooved in accordance with Gruvlok® grooving specifications....................... 174 Model FTV Tri-Service Valve ............ 7042 Outlet Coupling ................................................................ -GF & -FF AnvilFlexTM ... 7312 HDPE Flange Adapter ........... 182 cAutIon: Proper torquing of coupling bolts is required to obtain specified performance......... 159 FIG................168 FIG............... 161 FIG................... ............................... 7046 Clamp-T® Branch Outlets....... * Non-lubricated bolt torques.................. anvilintl. 7401 1 Check gasket to be sure it is compatible for the intended service. Pipe joint separation may result in significant property damage and serious injury. Gasket should not be visible between segments after bolts are tightened. The bolt pads are to have equal gaps on each side of the coupling. Apply a thin coating of Gruvlok lubricant to the exterior surface and sealing lips of the gasket. 4 5 nuts alternately and equally to the specified bolt torque. Place one housing over the gasket. pull the gasket into position centering it between the grooves on each pipe. To install the larger sizes align the tongue and pocket of the couplings appropriately and tighten the nuts alternately to the specified bolt torque. When properly assembled there will be a small equal gap between the adjacent bolt pads. making sure the housing keys fit into the pipe grooves. On couplings 10" and larger.12 153 . Reinsert the bolt and run-up both nuts finger tight. Gasket installation— Slip the 3 On couplings 10" and larger it may be easier to turn the gasket inside out then lubricate and slide the gasket over the pipe end as shown. cAutIon: Uneven tightening may cause the gasket to pinch. joint leakage and pipe joint separation. lower bend load capabilities. pipe ends. battery strength and operational variations. check & lubricate Gasket— 2 gasket over the pipe end making sure the gasket lip does not overhang the pipe end. www. Some applications require lubrication of the entire gasket surface. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. Swing the other housing over the gasket and into the grooves on both pipes. Gasket should not extend into the groove on either pipe. flip or roll the gasket into centered position. cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. tiGhten nuts— Securely tighten Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves. Under torquing the bolts may result in lower pressure retention capabilities. aliGnment— After aligning the two housinGs— Remove one nut and bolt and loosen the other nut. 6 assembly is complete— notE: Sizes 16" and larger are cast in multiple segments.GruVLoK InStALLAtIon And ASSEMBLY Rigidlok® Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. making sure the tongue and recess of each housing is properly mated. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. Be careful that foreign particles do not adhere to lubricated surfaces. keeping the gaps at the bolt pads evenly spaced.com GL-7. GruVLoK InStALLAtIon And ASSEMBLY fiG. assembly is complete— notE: The housings for sizes 16” and larger are cast in four or more segments. cAutIon: Uneven tightening may cause the gasket to pinch. housinGs— Place the coupling 5 alternately and equally to the specified bolt torque. Under torquing the bolts may result in lower pressure retention capabilities. lower bend load capabilities. On couplings 10" and larger. Apply a thin coating of Gruvlok lubricant to the exterior surface and sealing lips of the gasket. The housing bolt pads must make metalto-metal contact.Metal-to-Metal. to InStALL: Loosely pre-assemble the segments into two “Housing Halves” making sure that the alignment tang(s) and slot(s) on the bolt pad(s) are properly mated. 7001 Standard Coupling 1 Check gasket to be sure it is compatible for the intended service. 154 www. flip or roll the gasket into centered position. Be careful that foreign particles do not adhere to lubricated surfaces. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. The coupling is properly installed when all bolt pads are firmly together . battery strength and operational variations.com GL-7. cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply.anvilintl. On couplings 10" and larger it may be easier to turn the gasket inside out then lubricate and slide the gasket over the pipe end as shown. Insert bolts and turn nuts finger tight. pull the gasket into position centering it between the grooves on each should not extend into the groove on either pipe. Gasket installation— Slip the 3 pipe ends. tiGhten nuts— Tighten the nuts 6 Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves and the bolt pads are in firm even metalto-metal contact on both sides of the coupling. check & lubricate Gasket— 2 gasket over the pipe end making sure the gasket lip does not overhang the pipe end.12 . Pipe joint separation may result in significant property damage and serious injury. aliGnment— After aligning the two 4 housing halves over the gasket making sure the housing keys engage the grooves. Install the “Housing Halves” as shown in steps 4 & 5. joint leakage and pipe joint separation. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. See chart for torque requirements. centering it between the grooves on each pipe. the bolt pads are in firm even metal-to-metal contact on both sides of the coupling. 7401-2 1 Check gasket to be sure it is compatible for the intended service.300 250 .250" wall thickness Pipe preparation Grooved dimensions must conform to the Gruvlok Roll/Cut groove specification Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 7001-2 & fiG. Gasket should not extend into the groove on either pipe.com GL-7. bolts— Apply a thin coat of Xtreme 6 the pipe joint to assure the coupling keys are fully engaged in the pipe grooves. Gasket installation— Slip the 3 pipe ends together.12 155 . Be careful that foreign particles do not adhere to lubricated surfaces.anvilintl.-Lbs Lubrication – 14 16 18 20 24 ⁄8 180 .300 375 . pull the gasket into position.GruVLoK InStALLAtIon And ASSEMBLY 2-Piece Large Diameter Standard Groove Couplings • • • 7001-2 & 7401-2 bolts must be lightly coated with Gruvlok Xtreme™ lube before installation. and gasket is not visible. Bolt Size In. 7 Specified Bolt Torque Ft. Minimum wall pipe suitable for 14" – 24": 7001-2 & 7401-2 roll grooved installation is 0. verify that the torque output on the wrench is within the required torque range.220 250 . Apply a thin coat of Gruvlok lubricant to the exterior surface and sealing lips of the gasket. final assembly— Visually inspect AnSI SPEcIFIEd BoLt torQuE Pipe Sizes In. Tighten the nuts alternately and equally to the specified bolt torque. housinG— Place each housing half on 5 lube. cAutIon: When using an impact wrench. aliGnment— After aligning the two 4 the pipe and into each groove making sure that the gasket does not slip out of position in between the pipe ends or groove.425 375 . or Gruvlok Standard Lube to the bolt threads. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. cAutIon: Uneven tightening may cause the gasket to pinch. making sure the gasket lip does not overhang the pipe end.425 Gruvlok Xtreme™ Lubricant 1 1 11⁄8 11⁄8 www. check & lubricate Gasket— 2 gasket over the pipe end. Ideally. Hint: For horizontal assembly. Turning the gasket inside out will reduce the stretching necessary to put the gasket into position. again balancing the weight of the housings on the top of the pipe. Position the gasket centrally between the grooves of the two pipe ends. 4 Pull the two pipes into contact aligning the pipe ends. The end of this procedure will result in the gasket snapping into place. 156 www. lower bend load capabilities. 2 Turn the gasket inside out and slide the gasket completely over one of the pipe ends. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. Working your way around the circumference of the pipe. This helps prevent pinching of the gasket during assembly. in the Gruvlok Large Diameter Pipe Roll and Cut Groove Specifications.-lbs. The specified minimum torque for each nut is 600 ft. 7011 Standard Coupling 1 Inspect the pipe ends making sure the criteria.com GL-6. cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. The use of Gruvlok lubricants ensures compatibility between the lubricant and the gasket. place housing segment on top of the pipe to support the weight of the housing segment.-lbs.anvilintl. are met. The specified maximum torque for each nut is 800 ft. This will aid in step 4. Continue this procedure for all segments. 7 Firmly torque each bolt. joint leakage and pipe joint separation. 8 Installation of the Figure 7011 Standard Coupling is completed. Under torquing the bolts may result in lower pressure retention capabilities. cAutIon: Be careful not to pinch fingers during this step. (Dimension A) should be visible when the gasket is in proper position. flip the gasket toward the pipe end so that the proper side is facing out. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. 6 Secure the housings about the pipes making sure the coupling keys are engaged in the pipe end grooves. battery strength and operational variations. Secure the adjacent housing with an oval neck track bolt and heavy hex nut and then rotate the secured housings. Pipe joint separation may result in significant property damage and serious injury. 3 Lubricate the gasket sealing lips. 5 Lubricate the exterior surface of the gasket.GruVLoK InStALLAtIon And ASSEMBLY fiG. approximately 75% of the pipe’s gasket-sealing surface.11 . making sure the housing keys engage the grooves. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.GruVLoK InStALLAtIon And ASSEMBLY Lightweight Flexible Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. housinGs— With one nut unthreaded 5 tiGhten nuts— Tighten the nuts alternately and equally to the specified bolt torque. Gasket should not extend into the groove on either pipe. joint leakage and pipe joint separation. 3 4 to the end of the bolt. www.12 157 . Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves and the bolt pads are in firm even metalto-metal contact on both sides of the coupling. lower bend load capabilities.com GL-7. Insert the bolt and turn the nuts finger tight. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. 1 check & lubricate Gasket— Gasket installation— Slip the gasket over the pipe end. pull the gasket into position. 2 aliGnment— After aligning the two pipe ends together. assembly is complete— cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. Apply a thin coating of Gruvlok lubricant to the exterior surface and sealing lips of the gasket. 6 cAutIon: Uneven tightening may cause the gasket to pinch. Pipe joint separation may result in significant property damage and serious injury. centering it between the grooves on each pipe. unthread the other nut completely and swing the coupling housing halves over the gasket. Under torquing the bolts may result in lower pressure retention capabilities. 7000 Check gasket to be sure it is compatible for the intended service. Be careful that foreign particles do not adhere to lubricated surfaces. battery strength and operational variations. The housing bolt pads must make metalto-metal contact. making sure the gasket lip does not overhang the pipe end.anvilintl. The bolt pads are to have equal gaps on each side of the coupling. Reinsert the bolt and run-up both nuts finger tight. Be careful that foreign particles do not adhere to lubricated surfaces. 6 4 and loosen the other nut. 7400 Rigidlite® Coupling Check the gasket to be sure it is compatible for the intended service. both internal and external. 2 aliGnment— After aligning the two tube ends together. making sure the gasket lip does not overhang the tube end. Pipe joint separation may result in significant property damage and serious injury. 1 check & lubricate Gasket— Gasket installation— Slip the gasket over the one tube. making sure the housing keys fit into the tube grooves. pull the gasket into position. keeping the gaps at the bolt pads evenly spaced. housinGs— Remove one nut and bolt tiGhten nuts— Securely tighten nuts alternately and equally to the specified bolt torque.GruVLoK InStALLAtIon And ASSEMBLY fiG. battery strength and operational variations. making sure the tongue and recess of each housing is properly mated. 5 cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. of the gasket. The gasket should not extend into the groove on either tube. Apply a thin coating of Gruvlok Xtreme Lubricant to the entire surface. centering it between the grooves on each tube. Gasket should not be visible between segments after bolts are tightened. 158 www.11 . cAutIon: Uneven tightening may cause the gasket to pinch. lower bend load capabilities. Place one housing over the gasket. Under torquing the bolts may result in lower pressure retention capabilities. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation.com GL-6. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. 3 assembly is complete— Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves.anvilintl. joint leakage and pipe joint separation. Swing the other housing over the gasket and into the grooves on both tubes. the bolt pads may come close to metal-to-metal contact. www. centering it between the grooves on each tube. Swing the other housing over the gasket and into the grooves on both tubes.GruVLoK InStALLAtIon And ASSEMBLY Rigid Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Proper torquing of coupling bolts is required to obtain specified performance. Specified Bolt Torque* Ft. 6400 Coupling from Gruvlok is specially designed to provide a rigid pipe connection to meet the specific demands of copper tubing installation.anvilintl. The gasket should not extend into the groove on either tube or between the tube ends. joint leakage and pipe joint separation. making sure the tongue and recess of each housing is properly mated. notE: Copper is a soft material. making sure the housing keys fit into the tube grooves. 1 Wrench Size In. 4 housinGs– Remove one nut and bolt and loosen the other nut. Under torquing the bolts may result in lower pressure retention capabilities. cAutIon: Uneven tightening may cause the gasket to pinch. Re-insert the bolt and run-up both nuts finger tight. making sure the gasket lip does not overhang the tube end. cAutIon: Uneven tightening may cause the gasket to pinch. both internal and external. lower bend load capabilities. Assembly is complete. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. Be careful that foreign particles do not adhere to the lubricated surfaces. Proper torquing of coupling bolts is required to obtain specified performance. Apply a thin coating of Gruvlok® Xtreme Lubricant to the entire surface. Fast and easy swing-over installation of the rugged lightweight housing produces a secure. Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves. Available with the EPDM flush gap style gasket as the standard gasket.com GL-7. The gasket should not be visible between segments after the bolts are tightened. check & lubricate Gasket– 2 gasket over one tube. Under torquing the bolts may result in lower pressure retention capabilities. Place one housing over the gasket. of the gasket. 3 aliGnment– After aligning the two tube ends together.-Lbs ⁄8 1 ⁄2 5 ⁄8 3 ⁄16 7 ⁄8 11⁄16 11 30-45 30-45 60-90 Check the gasket to be sure it is compatible for the intended service. lower bend load capabilities. The bolt pads are to have equal gaps on each side of the coupling. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. keeping the gaps at the bolt pads evenly spaced. 5 tiGhten nuts– Securely tighten nuts alternately and equally to the specified bolt torque.12 159 . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. SPEcIFIEd BoLt torQuE Bolt Size In. pull the gasket into position. 6400 The Fig. joint leakage and pipe joint separation. Gasket installation– Slip the * Non-lubricated bolt torques. The gasket should not be visible between segments after the bolts are tightened. in some cases. rigid pipe joint. 2 aliGnment— After aligning the two pipe ends. Swing the other half of the coupling into position around the gasket and into the grooves. pull the gasket into position centering it between the grooves on each pipe.anvilintl. Check gasket to be sure it is compatible for the intended service. Insert locking pin into handle linkage to secure handle in closed position. Press firmly down on the handle until it makes contact with the coupling housing. Apply a thin coating of Gruvlok lubricant to the exterior surface and sealing lips of the gasket. The result may be an unsuitable pipe joint and unusable coupling assembly. (See Caution. 3) When re-using coupling and gasket. 3 4 coupling over the gasket as the coupling keys fit firmly into the grooves on each pipe end. 1 check & lubricate Gasket— Gasket installation— Slip the gasket over the pipe end making sure the gasket lip does not overhang the pipe end. 6 cAutIon: 1) Hammering or banging on the handle or coupling housing could cause serious damage to the locking device and coupling assembly. housinGs— Put one half of the open lock couplinG— Fit the nose of the locking handle in the notch of the opposite housing.) 5 assembly is complete— Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves and the bolt pads are in firm even metal-to-metal contact on both sides of the coupling. distortion or any other damage. 7003 Hingelok™ Coupling NOTE: Remove locking pin from handle before opening coupling. 160 www. Gasket should not extend into the groove on either pipe.GruVLoK InStALLAtIon And ASSEMBLY fiG. always inspect gasket for damage and hinge/ handle assembly for looseness. Be careful that foreign particles do not adhere to lubricated surfaces.com GL-7.12 . 2) Care needs to be taken so that fingers do not get caught or pinched when handle is placed in locked position as a result of cam action of handle assembly. 12 161 . a Gasket Center Rib Gasket Reducing Coupling Housing Proper Position of The Gasket Sealing Lips 4 coupling housing halves over the gasket making sure the housing keys engage the grooves. A illustrates the correct position of the Fig. www. cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. Under torquing the bolts may result in lower pressure retention capabilities. cAutIon: In vertical installations the pipes must be supported to prevent telescoping during installation. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 3 fiG. and insert the larger pipe end into the gasket. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. 6 assembly complete— notE: Fig. The housing bolt pads must make metal-to-metal contact. Be careful that foreign particles do not adhere to lubricated surfaces. 1 check & lubricate Gasket— Gasket installation— Place the smaller opening of the gasket over the smaller pipe. Insert bolts and turn nuts finger tight. battery strength and operational variations. Angle the gasket over the pipe end and pull the gasket lip open around the circumference of the pipe. 7010 check gasket to be sure it is compatible for the intended service. 2 aliGnment— Align the adjoining pipe center lines.anvilintl. 7010 Reducing Coupling gasket and housing properly assembled onto adjacent pipe ends. Apply a thin coating of Gruvlok lubricant to the exterior surface and sealing lips of the gasket. lower bend load capabilities. 5 tiGhten nuts— Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves and the bolt pads are in firm even metal-to-metal contact on both sides of the coupling.GruVLoK InStALLAtIon And ASSEMBLY Reducing Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. housinGs— Place the Tighten the nuts alternately and equally to the specified bolt torque. joint leakage and pipe joint separation. Pipe joint separation may result in significant property damage and serious injury.com GL-7. cAutIon: Uneven tightening may cause the gasket to pinch. Angle the pipe end slightly to the face of the gasket and tilt the pipe into the gasket to ease assembly. The center leg of the gasket should make flush contact with the pipe end and will prevent telescoping of the smaller pipe inside the larger. should not extend beyond the pipe end.) Swing the latch bolt out of the slot.11 . if the valve is rubber faced in the area designated by the sealing surface dimensions (A Max. (See Figure below) Gasket "A" Check the gasket to assure that it is properly suited for the intended service. the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the rubberfaced flange. The lip of the gasket. When mating to a wafer valve (lug valve).anvilintl.GruVLoK InStALLAtIon And ASSEMBLY fiG. 4. Lubricate the entire exterior surface of the gasket.). When mating to valves or other component equipment where the flange face has an insert. loosen the latch bolt nut to the end of the bolt thread. 2. use procedure described in note 3. (It is not necessary to remove the nut from the latch bolt. When mating to a serrated flange surface. On the side without the hinge pin. The pipe should extend out beyond the end of the sealing lip by approximately 1/8" on the 2"-6" sizes and 3/16" on the 8"-12" sizes. a standard full-faced flange gasket is installed against the serrated flange face.com GL-6. including the sealing lips. The flange gasket cavity must face the pipe end. 3 Latch Bolt Note: This side must face the mating flange The Gruvlok Flange gasket must be inserted so that the sealing lips face toward the pipe end and the mating flange. Tighten the nut until there is a 1/16" gap between the flange halves at location “A”. using the proper Gruvlok lubricant. 1 2 Place the latch bolt back into the slotted hole. Check pipe end for proper grooved dimensions and to assure that the pipe end is free of indentations and projections that would prevent proper sealing of the Gruvlok flange gasket. 7012 Gruvlok Flange (2"–12") APPLIcAtIonS WHIcH rEQuIrE A GruVLoK® FLAnGE AdAPtEr InSErt: 1. When mating to a rubber-faced metal flange. Open the Gruvlok Flange and place around the grooved pipe end with the key section fitting into the groove. place the Gruvlok Flange Adapter Insert between the valve and the Gruvlok Flange. and the Gruvlok Flange Adapter Insert is placed between the Gruvlok Flange and the standard flange gasket. to B Min. 162 www. 3. sealing on the pipe. Ensure that steel Flange the Insert is compatible with the fluids Adapter Insert in the systems and with adjacent piping components. bolt holes. The flange faces should have metal-tometal contact. 7012 Stretch the Gruvlok gasket around the pipe end and then press the gasket into the cavity between the pipe O. tank. The Flange Adapter Insert will be exposed Do not use a to the fluids in the system. 5 Verify that the mating flange face is hard. All the bolts or studs must be torqued to the mating flange bolts specified torque. tighten the nuts on the latch bolts alternately to the specified latch bolt torque. It is important to line up the bolt holes before bringing the two flanges together. 6 fiG. in copper systems or in systems where galvanic corrosion is possible. c2 Insert a flange bolt or stud with material properties of SAE J429 Grade 5 or higher through the bolt holes and thread a nut on hand tight. CAUTION: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. When using a flange insert. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. Under torquing the bolts may result in lower pressure retention capabilities.11 163 . joint leakage and pipe joint separation.anvilintl. c1 fiG. www. Pipe joint separation may result in significant property damage and serious injury. Assure the gasket is still in the proper position and align Gruvlok Flange bolt holes with the mating flange.. flat and smooth. 7012 Flange requires the use of a Flange Adapter Insert when used against rubber surfaces (Figure C1). Tighten the nuts alternately and evenly so the flange faces remain parallel. 4 With the gasket in place apply lubricant to the exposed gasket tip. Sliding the flanges into place will dislodge the gasket and cause leakage to occur. etc.com GL-6.D. which would prevent proper sealing of the Gruvlok Flange gasket. 7 NOTE: The Gruvlok Fig. The gasket must be properly positioned as shown in the figure below. which will seal on the mating flange. and the flange.GruVLoK InStALLAtIon And ASSEMBLY Gruvlok Flange (2"–12") Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. the flange housings must be in firm metal-to-metal contact. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. serrated flange surfaces or mating flanges with inserts (Figure C2). pump. CAUTION: Proper torquing of flange bolts is required to obtain specified performance. it is important that the insert is properly aligned with the gasket prior to tightening the bolts. free of indentations. Continue this procedure until all bolt holes have been fitted. battery strength and operational variations. lower bend load capabilities. 4 Tighten the nuts evenly to the specified mating face bolt torque so that the flange faces remain parallel and make firm even contact around the entire flange. Place the flange halves around the pipe and complete the assembly as described in Step 1. Move around the gasket in both directions until the gasket is fully seated in the flange gasket cavity. The wide gasket lip must seal on the pipe surface diameter and the narrow gasket lip must face the mating flange. firm metal-to-metal contact. Be careful that foreign particles do not adhere to lubricated surfaces.GruVLoK InStALLAtIon And ASSEMBLY fiG. Pipe joint separation may result in significant property damage and serious injury. Alternately and equally tighten the latch bolts and nuts to the specified latch bolt torque. Under torquing the bolts may result in lower pressure retention capabilities.anvilintl. Insert the next bolt or stub opposite the first and again thread the nut on hand tight. Continue this procedure until all bolt holes have been fitted. Pull the two flanges into contact using care to assure that the gasket remains fully seated within the gasket cavity during assembly. Figure 7012 Gruvlok Flanges should not be used with tie rods nor in a configuration with a wafer valve between two 7012 flanges. Insertion of the flange bolts prior to contact of the flanges will help in the alignment of the flanges. 7012 Gruvlok Flange (14"–24") Gruvlok® Flanges of 14" size and larger are cast in four segments to ease handling during assembly. 5 cAutIon: Proper torquing of flange bolts is required to obtain specified performance. notE: Design of the Gruvlok Flange provides sealing only with the special Gruvlok Flange gasket. 2 The correct position and relationship of the components of the Gruvlok Flange assembly is shown in the Figure above. 7012 GRUVLOK FLANGE GASKET CAUTION: GASKET MUST BE FULLY SEATED AGAINST THESE THREE SURFACES PIPE SURFACE DIAMETER PROPER POSITION OF GASKET SEALING LIPS Place each Gruvlok Flange segment around the grooved pipe with the key section fitting into the groove and the flange gasket cavity facing the pipe end. Loosely assemble the segments using the four segment-bolts-and nuts. battery strength and operational variations. lower bend load capabilities. 3 Align the Gruvlok Flange bolt holes with mating flange bolt holes.D. Only Gruvlok Flange gaskets may be used with Fig.11 . 1 Check the gasket grade to verify that it is properly suited for the intended service. 14" – 24" FIG. 164 www. Bring the four flange segments into full. 7012 flanges. Place the Gruvlok Flange Gasket around the pipe end by pressing the gasket into the cavity between the pipe O. joint leakage and pipe joint separation. Lubricate the entire surface of the gasket and the flange cavity using the appropriate Gruvlok Lubricant. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. notE: Take care to assure that the gasket lip is not bent backwards and pinched between the two flanges. above. and flange recess. notE: An alternative method of assembly is to loosely preassemble two segments into two equal halves of the flange leaving a small gap (approximately 1/8") between the two segments of each flange-half. Insert a flange bolt or stud with material properties of SAE J429 Grade 5 or higher through the bolt holes and thread a nut on hand tight.com GL-6. Make sure the ribs on the outside of the gasket align with the recesses in the housing and the keys in the housing are in the grooves on both pipes. joint leakage and pipe joint separation.-Lbs. check & lubricate Gasket— Check gasket to 2 the gasket over one pipe end making sure the pipe abuts the gasket’s center ribs. Be careful that foreign particles do not adhere to lubricated surfaces. Re-insert the bolt and run-up both nuts finger tight.com GL-7. 4 housinG assembly— FIG. Continue tightening the nuts alternately and equally until the specified bolt torque is reached. place one side of the housing over the gasket. 3 With one nut and bolt removed and the other loosened. Rotate the gasket to align the outlet of the gasket to the same direction as the branch outlet. In. Securely tighten the nuts alternately and equally until they are completely tightened and there is no gap between the bolt pads. battery strength and operational Coupling Bolt Wrench Specified variations. The gasket should not extend into the groove on either pipe. 7042 These instructions are based on pipe grooved in accordance with Gruvlok® grooving specifications. ALWAYS USE A GRUVLOK LUBRICANT FOR PROPER COUPLING ASSEMBLY.GruVLoK InStALLAtIon And ASSEMBLY Outlet Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Under 1 7 ⁄2 x 3 ⁄8 3 torquing the bolts may result in lower 5 1 1 ⁄ 8 x 3 ⁄2 1 ⁄16 4 pressure retention capabilities. The nuts must be tightened alternately and evenly until fully tightened.anvilintl.12 165 . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. Thorough lubrication of the gasket is essential to prevent pinching and possible damage to the gasket. Gasket installation— Slip aliGnment— Align the pipe ends and pull the pipe into the gasket until the center ribs are in contact with the pipe ends. coupling bolts is required to obtain 1 1 3 11 1 ⁄ 2 ⁄ 8 x 2 ⁄ 8 ⁄16 specified performance. 7042 – SPEcIFIEd BoLt torQuE Specified bolt torque is for the oval neck track bolts used on Gruvlok® couplings and flanges. Make sure the recess in the outlet of the housing is properly aligned with gasket outlet. separation may result in significant property damage and serious injury. cAutIon: Make sure the ribs on the exterior of the gasket are enclosed in the housing recesses. 1 be sure it is compatible for the intended service. Ft. Over torquing 3 11 ⁄8 x 21⁄2 ⁄16 2 the bolts may result in damage to 1 7 the bolt and/or casting which could ⁄2 x 23⁄8 ⁄8 21⁄2 result in pipe joint separation. 5 tiGhten nuts— 6 assembly is complete 30-45 30-45 80-100 80-100 100-130 100-130 www. Check pipe ends for proper groove dimensions and to assure that the pipe ends are free of indentations and projections which would prevent proper sealing. lower 5 ⁄8 x 31⁄2 11⁄16 6 bend load capabilities. In. Size Size Size Bolt Torque * cAutIon: Proper torquing of In. Apply a thin coating of Gruvlok lubricant to the exterior surface and sealing lips of the gasket. Caution: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including AnSI SPEcIFIEd BoLt torQuE air pressure supply. Swing the other housing over the gasket and into the grooves on both sides of the pipe. Pipe joint * Non-lubricated bolt torques. Specified Bolt Torque * Ft. 5 6 assembly is complete FIGS. 3⁄4. U-bolt and/or casting which could result in lower pressure retention capabilities. The nuts must be tightened alternately and evenly until fully tightened.anvilintl. 7046 Clamp-T® Branch Outlets ALWAYS USE A GRUVLOK LUBRICANT FOR PROPER COUPLING ASSEMBLY. U-Bolt 1 ⁄2 5 ⁄8 3 ⁄4 ⁄8 7 ⁄8 11⁄16 11⁄4 7 30-40 60-80 100-130 130-180 * Non-lubricated bolt torques 166 www. cAutIon: Proper torquing of the bolts or U-bolts is required to obtain the specified performance. pipe joint leakage and pipe joint separation. -0) ⁄2. Thorough lubrication of the gasket is essential to assist the gasket into the proper sealing position. 4 tiGhten nuts—Alternately and evenly tighten the nuts to the specified bolt torque. 3 aliGnment—Align the strap around the pipe. lower bend load capabilities. AnSI SPEcIFIEd BoLt torQuE Bolt Size In. 2 check & lubricate Gasket— Gasket installation—Lubricate the exposed surface of the gasket. Insert the gasket back into the outlet housing making sure the tabs in the gasket line up with the tab recesses in the housing. Caution: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure. Be sure to remove any slag from inside the pipe. Align the outlet housing over the pipe hole making sure that the locating collar is in the pipe hole. Overtorquing the bolts or U-bolts may result in damage to the bolt.-Lbs. 7045 & 7046—SPEcIFIEd BoLt torQuE Specified bolt torque is for the oval neck track bolts and U-bolts used on the Gruvlok® Clamp-T’s. insert the bolts and tighten the nuts finger tight. pipe preparation—Cut the appropriate size hole in the pipe and remove any burrs.com GL-7. 7045 & fiG. Clean the gasket sealing surface within 5/8" of the hole and visually inspect the sealing surface for defects that may prevent proper sealing of the gasket.GruVLoK InStALLAtIon And ASSEMBLY fiG.12 . Apply a thin layer of Gruvlok lubricant to the back surface of the gasket. battery strength and operational variations. Be careful that foreign particles do not adhere to the lubricated surfaces. 11⁄2 2 21⁄2 3 4 1 11⁄2 2 21⁄2 23⁄4 31/2 41/2 Check the gasket to be sure it is compatible for the intended service. 1 11⁄4. Wrench Size In. Some sizes use a U-bolt design. BrAncH SIZE (Inches) 1 HoLE SAW SIZE (Inches) (+1/8. the gasket will extrude out from under the housing. Overtorquing the U-bolts may result in damage to the U-bolt and/or casting which could result in lower pressure retention capabilities.anvilintl. cAutIon: Proper torquing of the U-bolts is required to obtain the specified performance. pipe joint leakage and pipe joint separation. cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure. 6 assembly is complete— Visually inspect the assembly. Be careful that foreign particles do not adhere to the lubricated surfaces. 1 the pipe and remove any burrs. 4 U-bolt from the other side and fasten the nuts finger tight.GruVLoK InStALLAtIon And ASSEMBLY Branch Outlet Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.12 167 . lower bend load capabilities. Gasket installation— 3 aliGnment— Align the outlet housing over the pipe hole making sure that the locating collar is in the pipe hole. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. Pipe joint separation may result in significant property damage and serious injury.com GL-7. Clean the gasket sealing surface within 5⁄8" of the hole and visually inspect the sealing surface for defects that may prevent proper sealing of the gasket. Be sure to remove the slug from inside the pipe. 7044 ALWAYS USE A GRUVLOK LUBRICANT FOR PROPER BRANCH OUTLET ASSEMBLY. housinG assembly— Attach the 5 tiGhten nuts— Making sure the fitting is properly located over the pipe hole. battery strength and operational variations. pipe preparation and Gasket lubrication— Cut a 13⁄16" hole in 2 Lubricate the exposed surface of the gasket with Gruvlok® lubricant. Remove the gasket from the housing and apply a thin layer of Gruvlok® lubricant to the back surface of the gasket. tighten the nuts alternately and evenly to the specifed torque of 27 to 33 Lbs. (37 to 45 N-m).-Ft. Thorough lubrication of the gasket is essential to to assist the gasket into the proper sealing position. www. Insert the gasket back into the outlet housing making sure the tabs in the gasket line up with the tab recesses in the housing. SPEcIFIEd BoLt torQuE The nuts must be tightened alternately and evenly until fully tightened. 5 550 746 700 949 image 1 image 2 image 3 image 4 Working pressure and end load are based on a properly assembled Roughneck coupling with bolts fully torqued to the above specifications.anvilintl. Make sure the gasket does not overhang the pipe end. Not recommended for use on steel pipe with a hardness greater than 150 Brinell. cast iron or other brittle pipe. Place each half of the Roughneck coupling over the gasket. 3-4 80-100 1 25. *Bolt torque ratings shown must be applied at installation. on plain-end or beveled standard wall steel pipe and Gruvlok Plain-End Fittings. 5-8 125-200 11⁄4 31./DN(mm) 1 2 3 Check the gasket color code to verify that the gasket grade is properly suited for the intended service. HDPE. contact an Anvil Internationl Representative. For externally coated pipe applications./mm Bolt Torque Min.12 .com GL-7. 7005 Roughneck® Coupling Make certain the pipe ends are free of indentations. See Image 3. Apply a thin coating of Gruvlok Lubricant to the gasket lips and the exterior surface of the gasket and slip the gasket over one pipe. See Image 1 and the chart.4 200 271 250 339 notE: Torque requirements must be met and housing halves must be assembled with equal gaps between bolt pads.8 250 339 300 406 10 250 13⁄4 44. Roughneck Couplings are designed to be used on plain-end pipe and Gruvlok Plain-End Fittings only. Reinstallation after a disassembly will require that the threads on the bolt and in the nut are clean and lubricated with a light oil. projections.5 500 678 600 814 12 300 13⁄4 44. Gasket Pipe Housing Grippers 168 www.-Lbs.21⁄2 50-65 1 25. Mark each pipe at a distance from the pipe end according to the pipe run size./N-m Ft. weld splatter.GruVLoK InStALLAtIon And ASSEMBLY fiG.4 4 5 6 7 Align the second pipe and while holding the pipe in the butted position slide the gasket back over the second pipe end. or other imperfections which could prevent proper sealing of the gasket. See Image 4 and chart for bolt torque.16 350-400 13⁄4 44. 150 203 Max 190 257 Ft. The gasket should be equally spaced between the lines scribed on each pipe. Tighten the nuts alternately and uniformly until the required bolt torque is reached. Pipe Size In. Distance from pipe end mark In. See Image 2.-Lbs./N-m 2 . making sure that the tongue on one housing half is aligned with the recess on the other housing half. plastic.5 550 746 700 949 14 . verify that the output of the torque wrench is within the required torque range.anvilintl. 5 nuts alternately and equally to the required indicator. and for 5" and larger couplings ensure the housings are in firm even metal-to-metal contact on both sides. centering it between the grooves on each pipe. please use the table below for required torque values.130 100 .180 * 6 8 10 12 ⁄8 1 1 1 * * * * * Torque required to bring housing metal-to-metal contact.GruVLoK InStALLAtIon And ASSEMBLY High Pressure Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Apply a thin coat of Gruvlok Lubricant to the exterior surface and sealing lips of the gasket. pull the gasket into position. 2 21⁄2 3 4 5 ⁄8 5 ⁄8 5 ⁄8 3 ⁄4 7 ⁄8 5 100 . tighten nuts till housings are in metal-to-metal contact.com GL-7. tiGhten nuts— Securely tighten 6 assembly is complete— Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves. Gasket installation— Slip the 3 pipe ends together.4".130 100 . ensure the gaps on each side are evenly spaced. Gasket should not extend into the groove on either pipe aliGnment— After aligning the two 4 housinGs— Place each housing halves on the pipe making sure the housing key fits into the groove. check & lubricate Gasket— 2 gasket over the pipe end. Bolt Size In.12 169 . For 7004 5" and larger. 7 Torque Ft. www. For 2" . Bolt Size In. SPEcIFIEd BoLt torQuE Size In. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. Be careful that foreign particles do not adhere to lubricated surfaces. Be sure that the tongue and recess portions of the housing mate properly. It is recommended that a torque wrench be used for accurate assembly in order to obtain specified performance. For 2" .130 130 .4" 7004 couplings. 7oo4 1 Check gasket to be sure it is compatible for the intended service. Torque Ft.-Lbs cAutIon: When using an impact wrench. making sure the gasket lip does not overhang the pipe end. Insert the bolts and run up the nuts finger tight.-Lbs Size In. 130 100 .180 * 6 8 10 12 ⁄8 1 1 1 * * * * * Torque required to bring housing metal-to-metal contact.4". Pipe joint separation may result in significant property damage and serious injury. stop when the center gasket leg comes in contact with the pipe end. ensure the gaps on each side are evenly spaced. 4 nuts alternately and equally to the required indicator. 7 Torque Ft.anvilintl. tighten nuts till housings are in firm metal-to-metal contact. 7oo4 with eG® Gasket Figure 7004 with EG® gasket requires specified pipe end groove dimensions and fittings. Bolt Size In. 1 Check gasket to be sure it is compatible for the intended service. Ensure pipes are aligned properly. Insert the bolts and run up the nuts. For 2" .-Lbs cAutIon: When using an impact wrench. It is recommended that a torque wrench be used for accurate assembly in order to obtain specified performance. High Pressure Coupling with End Guard® Gasket cAutIon: Not using the correct groove dimensions will result in pipe joint separation. check & lubricate Gasket— 2 Slip the gasket half way on to the pipe end. Gasket & pipe installation— 3 housinGs— Place each housing halves on the pipe making sure the housing key fits into the groove. Be sure that the tongue and recess portions of the housing mate properly. For 5" and larger.GruVLoK InStALLAtIon And ASSEMBLY fiG. Apply a thin coat of Gruvlok Lubricant to the exterior surface and sealing lips of the gasket. Bolt Size In. tiGhten nuts— Securely tighten 5 inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves. see page 203 for groove dimensions. Be careful that foreign particles do not adhere to lubricated surfaces. 170 www. verify that the output of the torque wrench is within the required torque range. Slide the second pipe end half way into the gasket. stopping then the pipe end comes in contact with the center gasket leg. and for 5" and larger couplings ensure the housings are in firm even metal-to-metal contact on both sides.130 130 .12 . assembly is complete— Visually SPEcIFIEd BoLt torQuE Size In.130 100 .-Lbs Size In. please use the table below for required torque values. 2 21⁄2 3 4 5 ⁄8 5 ⁄8 5 ⁄8 3 ⁄4 7 ⁄8 5 100 . For 2" .com GL-7. finger tight.4" couplings. Torque Ft. /N-m ⁄2 X 2 ⁄8 3 1 80 110 100 150 ⁄2 X 3 1 80 110 100 150 5 ⁄8 X 3 ⁄2 ⁄4 X 43⁄4 100 135 130 175 3 130 175 180 245 www. which could prevent proper sealing of the gasket.4 mm) 11⁄4" (31. The nuts must be tightened alternately and evenly until fully tightened. lower bend load capabilities.-Lbs. 7305 Make certain the pipe ends are free of indentations. Pipe joint separation may result in significant property damage and serious injury.8 mm) 13⁄4" (44. Under torquing the bolts may result in lower pressure retention capabilities. joint leakage and pipe joint separation.203 mm) 10 & 12" (254 . 4 Place the Figure 7305 housing casting over the gasket. Make sure the gasket does not overhang the pipe end. projections or other imperfections. SPEcIFIEd BoLt torQuE Specified bolt torque is for the oval neck track bolts used on Gruvlok® couplings. 5 Insert the bolts and secure the nuts alternately and uniformly until the bolt pads are in contact. 7305 SPEcIFIEd BoLt torQuE Coupling Bolts In.GruVLoK InStALLAtIon And ASSEMBLY HDPE Coupling Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. There is no gap between the bolt pads and the bolt torque should be within the range given when the coupling is properly assembled. 1 Minimum Ft. Refer to the Specified Bolt Torque Table. Gruvlok XtremeTM Lubricant contains silicone. The Gasket color code is green for EPDM and orange for Nitrile (Buna-N). Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG.305 mm) Distance to Mark 1" (25. 3 Slip the gasket over one of the pipe ends. Caution: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. battery strength and operational variations. cAutIon: Use only Gruvlok XtremeTM Lubricant. If silicone is unacceptable for the application contact Gruvlok for the lubrication recommendation. Alternate and even tightening of the bolts will significantly reduce the torque needed to close the gap at the pipe joint. making sure the tongue on one casting is aligned with the recess of the other casting. FIG.5 mm) 1 2 NOTE: Make certain the HDPE pipe end is square cut to 1⁄8" maximum for the 2" to 4" and 5⁄32" maximum for the 6" and larger sizes./N-m Maximum Ft. Mark each pipe at a distance from the end of the pipe according to the pipe size: Size Inches 2-4" (51 . The gasket must be positioned centrally between the lines on the pipe ends. Apply a thin coating of Gruvlok XtremeTM Lubricant to the gasket lip and the exterior surface of the gasket. Torque all bolts to the required bolt torque levels.12 171 .anvilintl. Align the second pipe and while keeping the pipes in the butted position slide the gasket back over the second pipe end.-Lbs.com GL-7.102 mm) 5-8" (127 . Check to assure the gasket material is acceptable for the intended service. CAUTION: Proper torquing of coupling bolts is required to obtain specified performance. FIG. slide the gasket back over the second pipe end. Gruvlok XtremeTM Lubricant contains silicone. 5 Insert the bolts and secure the nuts alternately and uniformly until the bolt pads are in contact. projections or other imperfections./N-m ⁄2 X 23⁄8 1 80 110 100 150 ⁄2 X 3 80 110 100 150 5 ⁄8 X 31⁄2 ⁄8 X 5 ⁄2 1 100 135 130 175 7 180 245 220 300 172 www. CAUTION: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. The nuts must be tightened alternately and evenly until fully tightened. Make sure the gasket does not overhang into the pipe groove. 7307 HDPE Transition Coupling Make certain the HDPE pipe end is square cut to 1⁄8" maximum for the 2" to 4" and 5⁄32" maximum for the 6" and larger sizes.12 . 1 Minimum Ft. 4 Place each half of the coupling housing over the gasket./N-m Maximum Ft.-Lbs.-Lbs. making sure the housing grooved end is directed into the pipe groove. Under torquing the bolts may result in lower pressure retention capabilities. Align the second pipe and while holding it in the butted position. joint leakage and pipe joint separation.anvilintl. cAutIon: Use only Gruvlok XtremeTM Lubricant. 1 2 Check to assure the gasket material is acceptable for the intended service. lower bend load capabilities. Apply a thin coating of Gruvlok XtremeTM Lubricant to the gasket lips and the exterior surface of the gasket. Make sure the gasket does not overhang the pipe end.GruVLoK InStALLAtIon And ASSEMBLY fiG. The gasket must be positioned on the gasket seat surface of the grooved steel pipe. There is no gap between the bolt pads and the bolt torque should be within the range given when the coupling is properly assembled. Torque all bolts to the required bolt torque levels. SPEcIFIEd BoLt torQuE Specified bolt torque is for the oval neck track bolts used on Gruvlok® couplings. The steel pipe must be grooved in accordance with Gruvlok® Grooving Specifications for Steel Pipe. If silicone is unacceptable for the application contact Gruvlok for the lubrication recommendation. The Gasket color code is green for EPDM and orange for Nitrile (Buna-N). Refer to the Specified Bolt Torque Table. 7307 SPEcIFIEd BoLt torQuE Coupling Bolts In. indentations. Alternate and even tightening of the bolts will significantly reduce the torque needed to close the gap at the pipe joint. The pipe ends must be free of scratches.com GL-7. which could prevent proper sealing of the gasket. battery strength and operational variations. 3 Slip the gasket over one of the pipe ends. Pipe joint separation may result in significant property damage and serious injury. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. cAutIon: Use only Gruvlok XtremeTM Lubricant. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. 7312 LAtcH BoLt torQuE Latch Bolts In. 4 Tighten the housing nut until the housing bolt pads make firm metal to metal contact. which could prevent proper sealing of the gasket. projections./N-m Maximum Ft. Note: Take care to assure the gasket lip is not bent backwards and pinched between the two flanges.-Lbs./N-m Maximum Ft. Do not let the pipe extend beyond the flange face. lower bend load capabilities./N-m ⁄8 X 3 110 149 140 190 3 ⁄4 X 31/2 220 298 250 339 www. battery strength and operational variations. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. Under torquing the bolts may result in lower pressure retention capabilities. 7312 1 2 Make certain the pipe end is square cut to 1 ⁄8" maximum for the 4" and 5⁄32" maximum for the 6" and 8" sizes./N-m ⁄8 X 23⁄8 ⁄4 X 2 ⁄4 3 100 135 130 175 3 130 175 180 245 FIG. 5 Minimum Ft. Continue this procedure until all holes have been fitted. 7312 MAtInG FLAnGE BoLt torQuE Mating Flange Bolts In. Gruvlok XtremeTM Lubricant contains silicone. Refer to the Specified Mating Flange Bolt Torque Table. The gasket color code is green for EPDM and orange for Nitrile (Buna-N). align the face and the flange face with the end of the pipe. SPEcIFIEd BoLt torQuE For LAtcH & MAtInG FLAnGE BoLtS Specified bolt torque is for the latch and mating flange bolts used on Gruvlok® flanges. 3 Place the housing over the end of the pipe and using a straight edge.-Lbs. Inspect the surface of the mating flange to be assured the surface is free of dimensions of the mating flange to be assured that the scratches. cAutIon: Use of an impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. cAutIon: Proper torquing of latch and mating flange bolts is required to obtain specified performance. Check to assure the gasket material is acceptable for the intended service.com GL-7. Pipe joint separation may result in significant property damage and serious injury. Torque all bolts to the required latch bolt torque levels. The nuts must be tightened alternately and evenly until fully tightened. Tighten the flange face nuts alternately and evenly so that the flange faces remain parallel and make firm contact around the entire flange.-Lbs. indentations. FIG. 7 Align the Gruvlok Flange bolt holes with the mating flange bolt holes. Insert a standard bolt or stud through one bolt hole and thread the nut on hand tight. 5 Minimum Ft. Torque all bolts to the required mating flange joint torque levels.-Lbs. Insert the next bolt or stud opposite the first and thread the nut on hand tight. joint leakage and pipe joint separation. or other imperfections. If Silicone is unacceptable for the application contact Gruvlok for the lubrication recommendation. Be sure the flange sealing lips are facing out.GruVLoK InStALLAtIon And ASSEMBLY HDPE Flange Adapter Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Apply a thin coating of Gruvlok XtremeTM Lubricant to the gasket lips and outside surface of the gasket. 5 6 Position the Gruvlok Flange gasket around the pipe end and press the gasket into the flange gasket pocket.12 173 .anvilintl. Refer to the Specified Latch Bolt Torque Table. ) Install the other prepped and lubricated pipe end into the Sock-It fitting in the same manner. 4 WArnInG: System pressure must be relieved and vented. Other lubricants may affect gasket performance.com GL-6. notE: When Allied XL pipe is used it is necessary only to remove sharp edges and burrs at the end of the pipe. The end of the Sock-It Fitting should be within 1⁄16" from the edge of the marking on the pipe. Tighten the lock bolt until the bolt head bottoms against the threaded boss.11 . indentations. of the Sock-It Fittings as this would prevent proper insertion of the pipe. 2 Apply a light coating of GRUVLOK Lubricant to the gaskets located in each end of the Sock-It Fitting. Reinstallation may be accomplished as described in Steps 1-4. and sharp edges which could affect proper gasket sealing. No additional cleaning is required. projections. (NOTE: The 21⁄2" Sock-It fitting has 2 locking bolts for each pipe end. 11⁄4". 174 www. cAutIon: Do NOT hammer fitting on. mark the pipe at a distance of 11⁄2" from the end for 1". (See Step 1). Bolt end must be inspected to assure bolts ability to cut into pipe. and 11⁄2" size fittings and 13⁄4" for the 2" & 21⁄2" size fittings. and the system drained of fluid prior to loosening the lock bolts to remove or reposition the Sock-It Fitting. 5 Sock-It Fittings may be removed by loosening the lock bolts. Rotate the fitting until the desired position is obtained.anvilintl. 1 Check all lock bolts to be sure they do not extend into the I. As a guide for installation.GruVLoK InStALLAtIon And ASSEMBLY Gruvlok sock-it® fitting Pipe surface shall be cleaned at least 1" from the end of the pipe to remove any coating. Also apply a light coating of lubricant to the pipe ends to further ease insertion of the pipe into the Sock-It Fitting. notE: Use only Gruvlok Lubricants. 3 Insert the prepped and lubricated pipe end into the Sock-It Fitting until the pipe end makes contact with the internal pipe stop. A slight twist while pushing fitting and pipe together will ease the required insertion force. Replace bolts in cases where bolt end sharpness has been comprised.D. cAutIon: Safety glasses should be used and the probe should not be left inserted into fittings for prolonged periods of time (overnight./lbs. Locate Pressure Differential on left hand side of chart and extend line horizontally across to valve size being used. It is not recommended to mount a valve directly to the pump as this could cause undesirable noise in the system. Refer to Tri-Service Performance Curves with valve in full open position (See Determining Flow Rate with Valve in Throttled Position Section on page 177). 5 6 7 Install valve in the direction of the flow arrows on the valve body.11 175 . The body is not designed to support the piping weight.com GL-6.380 690 250 Pressure (kpa) B&C 2. The Gruvlok Tri-Service valve bodies have anti-rotation lugs on the inlet and outlet. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories ftv-s (straight) & ftv-a (angle body) 1 2 3 4 The valve can be mounted to flanged equipment using Gruvlok Flange Adapter or industry standard grooved coupling. Inspect the “O” Ring for any cuts or nicks and replace if necessary. Pressure (psi) -46° 400 375 300 250 200 100 0 -50° -20° -0° 50° -29° -18° 10° pressure – temperature limits Temperature° C 38° 66° 93° 110° Remove the body bolts from valve body using Allen Key. www.070 1.760 2. suitable for system pressure and temperatures encountered.). A Temperature° F 100° 150° 200° 230° Note: for temperatures between 230°F and 300°F (110°C and 149°C) specify Viton Elastomers. Drop line vertically down and read flow rate from bottom of chart. provide a ridged rotation free installation.anvilintl.724 1. as leakage from the PMP may occur when probe is removed. 1 2 3 4 field conversion (straight to angle pattern valve) Open valve at least one complete turn. Spool piece required is based on a minimum recommended space of 12" for pump sizes 2" x 2" to 6" x 6" and 24" for pump sizes 8" x 8" to 12" x 12". The valve body has been designed to handle the weight of the pump on vertical in-line installations. Sufficient clearance around the valve should be left for valve removal or repair.585 A B C LEGEND Gruvlok ductile iron flange adapters for ANSI 150# flanges Gruvlok ductile iron flange adapters for ANSI 300# flanges Grooved end with 375 psi rated pipe coupling Replace body bolts and torque evenly to 70 ft. flow measurement Where approximate indication of flow is acceptable the Gruvlok Tri-Service valve can be used. These lugs. Pipe supports should be provided under the valve and strainer bodies. 2. etc. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.GruVLoK InStALLAtIon And ASSEMBLY Tri-Service Valve installation: The valve should be mounted to a spool piece on the discharge side of the pump. combined with the Flange Adapters. flow measurement valve in wide open position Measure and record the differential pressure across the valve using a Flow Meter with high pressure range transducer or pressure gauges with PMP adapters. It is recommended that the piping be supported by hangers. tYPIcAL InStALLAtIonS Base-Mounted Single Suction Base-Mounted Double Suction Vertical In-Line Rotate one half of the valve body 180° making sure the lower valve seat and “O” Ring stay in position. anvilintl. and the flange recess. 3 NOTE: Take care to assure that the gasket lip is not bent backwards or pinched between the two flanges.com GL-7. 2 Proper position of gasket sealing lips 6 Swing the latch bolt back into the slotted hole. Installation is similar to the installation of the Figure 7012 with grooved pipe. Insert the next bolt or stud opposite the first and again thread the nut on hand tight. Align the Gruvlok Flange bolt holes with the mating flange bolt holes. 7012 Gruvlok Flange gasket must be inserted so that the sealing lips face toward the pipe end and the mating flange face and away from the Gruvlok Flange itself. 7012 Gruvlok Flange Adapter can be used with the FTV Tri-Service Valve.D. 7012 Gruvlok Flanges. pump. Grooved Pipe Gasket Loosen the nut on the latch bolt to the end of the bolt thread. Open the Gruvlok Flange and place it around the grooved pipe with the key section fitting into the groove.GruVLoK InStALLAtIon And ASSEMBLY ftv-s (straight) & ftv-a (angle body) Tri-Service Valve flanGe adapter installation: The Fig.) Swing the latch bolt out of the slot. tank. The gasket must be properly positioned as shown in Step 5. (See illustration) 5 Gruvlok Flange Flange.12 . Lubricate the entire surface of the gasket and the flange gasket cavity using Gruvlok lubricant. Insert a standard bolt or stud through the bolt hole. Torque all bolts to required flange joint torque levels. valve. etc. The Fig. 1 The correct positioning and relationship of all components comprising a Gruvlok Flange joint. Only Gruvlok Flange gaskets may be used with Fig. 7 4 START 1 6 9 14 16 11 8 3 4 10 12 15 2 5 13 7 Recommended Bolt Tightening Sequence 176 www. and thread a nut on hand tight. Tighten the nut until the flange halves make solid contact. The flange gasket cavity must face the pipe end. Tighten the nuts evenly so that the flange faces remain parallel and make firm even contact around the entire flange. Position the Gruvlok Flange Gasket around the pipe end and press the gasket into the cavity between the pipe O. (It is not necessary to remove the nut from the latch bolt. Check the gasket grade to verify that it is properly suited for the intended service. NOTE: Design of the Gruvlok Flange provides sealing only with the special Gruvlok Flange gasket. Continue this procedure until all holes have been fitted. Be careful that foreign particles do not adhere to lubricated surfaces. 1 .57 L/sec. (3 rings / 6 rings X 100) = 50% throttle 4" 20 80 60 40 1 .0 50 3.0 throttled is: 4000 6000 100pressure drop when 500 50% 1000 2000 (400 x 34)/100 = 136 USgpm FLOWRATE (US GAL/MIN) (25. 10" 10 PERCENT OF MAX FLOW 5"m) Differential Pressure in 5.5 2.5 2.0 Note: 5. The indicator on the plastic sleeve is aligned with the vertical scribed line on the stem. multiply with Full Position the flow rate from Step 4 by the percentage flow rate from Step 2 divided by 100. ( 1.0 4000 6000 200 400 Tri-Service Performance Curve To calculate flowValve rate ofin valve inOpen the throttled position.0 5. Calculate percentage of valve opening referring to table below: PRESSURE DROP (FT.65 6" 8" Number of rings open 3. 5.0 Locate percentage of valve opening on the bottom scale of Flow Characteristic Curve. Drop a line vertically down to read the flow rate at the bottom of the chart. 10" 20 0 10 premature 20 50 failure 100 200 400 3.com GL-6.4 ft.4 ft.anvilintl.0 500 1000 2000 FLOWRATE (US GAL/MIN) 10 20 50 100 FLOWRATE (L/SEC) 2. Scribed Lines www. 12" 10 5. 5). 0 20 40 60 80 100 PERCENT OF FULL OPEN flow indicator scale The valve stem with its grooved rings and positioning sleeve indicates the throttled position of the valve.65 m) 2. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories ftv-s (straight) & ftv-a (angle body) determininG flow rate with valve in throttled position: Record the size of valve and stem position using the Flow Indicator Scale (See Flow Indicator Section at bottom of page).0 To prevent valve it is not recommended FLOWRATE that the valve operate in (L/SEC) the throttled position with more than 25 ft.2 L/s).0 21/2" 2" 5 3 4" 5" 20 6" 8" 10" Measure and record the differential pressure across the valve in the throttled position. pressure drop (1. WG) PRESSURE DROP (MH2O) 5 3 20Example: Valve size 4 in. pressure differential. (1. 6). 2" 10 2 /2" 1 Solution: • From the Tri-Service Performance Curve (fig. On the Tri-Service Performance Curve locate the differential pressure obtained in Step 2 and project line horizontally across to intercept with Valve Performance Curve. valve. valve. with the scribed line on the stem. provide for approximate flow measurement.GruVLoK InStALLAtIon And ASSEMBLY Tri-Service Valve Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 50% open. The quarter turn graduations on the sleeve.0 • From Flow Characteristic Curve (fig.11 177 . Instead the pump impeller should be trimmed or valves located elsewhere in the system to partially throttle the flow. represents 34% of maximum flow. with a 5. Project line vertically up to intersect with the Valve Characteristic Curve and from this point project line horizontally across to the left of the chart and record the percentage of maximum flow rate. a 4 in. valve with 5. Inherent Flow Characteristic Curve with Valve in Throttled Position 100 12" 6" 4" 5" 8" 21/2" 3" PRESSURE DROP (FT.0 50 • Approximate flow of a 4 in. 12" a 4 in. WG) PRESSURE DROP (MH2O) VALVE SIZE Number of Rings (valve full open) 21/2 5 3 5 4 6 5 9 6 10 8 12 10 18 12 28 1 2 3 4 5 Tri-Service Performance Curve with Valve in Full Open Position 20 10 5.2 x 34)/100 = 8.0 100 5.4 ft. Note: The valve is shipped in the closed position.65 m) represents a flow of 400 USgpm (25. However. Torque to a maximum force of 45 ft. cAutIon: Safety glasses should be worn. valve will open to 51/2 turns which is just back of seating of valve. stem “O” Ring can be changed under full system pressure.11 . Inspect and clean “O” Ring cavity and install new “O” Ring and seat. To assure trouble-free check valve operation and shut off operation. Clean exposed portion of valve stem (Do not scratch). 1 2 3 4 5 6 7 8 Record the valve setting. as the metal-to-metal backseating does not provide a drip-tight seal. Valve disc stem also should be inspected and replaced if worn. There may be a slight leakage. Install the valve bonnet. Open valve to balance set point as recorded in Step 1. Turn the valve stem counterclockwise until the valve is fully open and will not turn any further. Remove seat and “O” Ring.anvilintl. Remove and replace the “O” Ring and gasket. “O” Ring is not used on valves 8" and larger./lbs of torque.GruVLoK InStALLAtIon And ASSEMBLY ftv-s (straight) & ftv-a (angle body) Tri-Service Valve operation To assure tight shut off the valve must be closed using a wrench with 25 to 30 ft. This will ensure good metal-to-metal contact and minimum leakage. 1 2 3 4 5 6 Drain system and remove valve from piping.com GL-6. Clean exposed portion of valve stem (Do not scratch). Tightening valve bonnet is necessary to stop any leaks. 178 www. Remove and replace the “O” Ring and gasket. repackinG of ftv valve under full system pressure Should it be necessary. Remove the body bolts from the body using an Allen Key. full open position of valve is 5 turns. Valve stem “O” Ring should be replaced at this time./lbs. seat replacement The valve bonnet may now be removed. the valve should be periodically opened and closed to keep valve seat and valve disc guide stem free of build up of system contaminants. maximum number of turns full open valve On valve sizes 21/2" and 3". which vary with the fluid temperature.com GL-6. Provisions must be made for easy access to the probe metering ports (P. adjust the handwheel position until the differential pressure reading across the venturi corresponds to the required GPM. 360° turn of opening when lined up with an arrowhead symbol.anvilintl. For optimum operation. as compared to water. • “Handwheel turns” dial: This dial is printed on the outer surface of a gearing mechanism located inside the lower half of the handle assembly (Fig. welding slag) and other contaminants. Both the handwheel turns dial and the micrometer scale indicate a valve position reading of 0. 4: GBV setting of 2. anvilintl. 2 Valves are circuit balancing valves that are selected to deliver the correct flow in a piping circuit based on line size and design flow rate. 1). flow rates must be corrected for the changes created by the fluid medium. The “0” on the micrometer scale should be within one half of 1 ⁄10th of a turn of the arrowhead symbol when the valve is closed hand tight. air entrapment in the fluid must be removed.npt threaded connections GBV GBV 6 fig.sweat (solder) connections: 6 7 GBV-S models are supplied with sweat style connections. As with any water system it is important to make provisions to keep the system clean. reading scale. Testing HVAC systems with pressurized air can be dangerous due to the high compressibility of air. Gbv-s . Overtightening when installing valves may result in fracturing of the valve body at the threads. 2). 6). Always follow local plumbing codes for installation best practices. (Go to Step 8) WArnInG: Anvil does NOT recommend leak testing an HVAC system with air due to safety concerns. Gbv-s & Gbv-t 1 2 3 Clean the system piping of debris (pipe scale. rust. Caution should be used when sweat style connection valves are installed to prevent overheating the valve.3 turns open). GBV’s may be installed in horizontal or vertical piping (as illustrated in Fig. cAutIon: Before soldering. DO NOT USE A WRENCH ON THESE VALVES – THEY SHOULD BE OPENED AND CLOSED HAND-TIGHT ONLY! Fig. www.5 to indicate the valve position in terms of the number of full turns. The arrow must point in the direction of flow for proper operation.0 indicates that the valve is closed. The operation of the valve is dependent on the fluid characteristics such as specific gravity and viscosity. Solder the valve body in line using 95/5 (95% tin. 5% antimony) type solder or equal. Anvil recommends that the GBV be protected during installation by wrapping a damp rag around the handle / bonnet assembly prior to soldering the valve into the line. (Fig. 3) • Micrometer Scale: This scale is marked 0 . Once the GBV installation has been completed and the system has been filled and purged.3 indicates that the valve is partially open (2. The valve operates from fully open to closed by a clockwise rotation of the orange handwheel using five 360° turns. To set the system flow. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 3) Fig.9 and is located on the upper half of the handle assembly. Each mark represents 1⁄10th of a full. 3: GBV setting of 0. SCALE DIAL 11 The valve is considered “zeroed” when fully closed hand tight. Two indicators describe the position of the valve: the handwheel turns dial and the micrometer scale. each valve loop must be adjusted to the correct flow setting. located above the handwheel turns display window. or call your local Anvil representative.M.’s).P. For installations using fluids other than 100% water. All threaded connections should be sealed using an approved pipe sealant per industry standards.com for appropriate correction factors. See www. ensure the valve is opened at least one full turn to avoid damage to the sealing O-ring due to overheating. Each complete 360° revolution of the handwheel is visible through a display window and is scaled 0 . and memory stop. operation: 8 9 fig. (Fig. 1 4 5 All GBV’s are marked with an arrow on the valve body to indicate direction of flow. 10 Gbv-t . To ensure accuracy of measurement Circuit Balancing Valves (GBV’s) should be located at least five pipe diameters downstream from any fitting and at least ten pipe diameters downstream from a pump (as illustrated in Fig.11 179 . Employ piping best practice when engaging pipe to threaded valves. GBV-T models are tapped with NPT threaded connections.GruVLoK InStALLAtIon And ASSEMBLY Five Turn Circuit Balancing Valves installation: Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. The memory stop will allow the valve to be fully closed for isolation and then reopened to the preset flow position. the valve may open as much as 5.P. the handle is damaged.M. DO NOT USE A WRENCH TO OPEN. Over-tightening may cause damage to the P. TURN INDICATOR HANDWHEEL STEM fig. 6 Venturi C v Performance Curve s Fig.com GL-7. 8 for both the GBV-S & GBV-T and a troubleshooting chart 180 www.0 indicates that the valve is fully opened. the hose with blue fitting downstream. • Insert the meter probe into the metering ports. adversely affecting the pressure measurement.12 . Read the pressure drop across the venturi with a digital meter.’s) during probe insertion and hookup of metering device. In some cases. 6) Turn the setscrew in a clockwise direction until it stops. do not bend.M. PArt nuMBEr 571155-022 571155-022 571155-022 571155-022 571155-022 571155-022 SIZE ⁄2" ⁄4" 1" 11⁄4" 11⁄2" 2" 1 3 Insert a 2. for isolating the piping during system maintenance. flow across the entire valve. as needed. Do not use any lubrication on the probes when inserting them.5 mm (or 3⁄32") Allen key through the hole provided in the valve’s handle cap. however. Determine flow rate by use of venturi Cv performance curves on page 4 or the Anvil Balancing Slide Rule.. the performance curves for these GBVs are calibrated only to 5. simply open the valve by turning the handwheel counterclockwise until the handle stops turning (the valve stem inside the handle has hit the memory setscrew). The locking nut on the probe is designed to hold it in the P. SET SCREW LOCK NUT CAP 16 17 18 cAutIon: Hot water leakage can occur from metering ports (P.anvilintl. As sealing is accomplished internally on the probe stem.0) or at a preset position.3 turns. The valve may now be closed tightly.P. or locking nut threads. or it may become damaged. The probe should not be left inserted into the fitting for prolonged periods of time. cAutIon: When inserting probe. If necessary. Wear protective eyewear and clothing to prevent personal injury when measuring pressure. 5: GBV setting of 5.GruVLoK InStALLAtIon And ASSEMBLY fiG. as leakage of the P. The handle of the GBV is not designed to be removable. For pressure drop vs. It is not necessary to tighten. as this will cause permanent damage to the probe.0 turns. it is only necessary to tighten the locking nut FINGERTIGHT. when taking readings. This is not a problem with the valve. This establishes the maximum opening position for this particular valve. simply wet the probes with clean water. etc. due to the depth of the stem threads. 13 14 Before taking a measurement reading. 12 Connect pressure measuring device to the GBV metering ports as follows: 15 After valve has been properly adjusted and without moving the handwheel.P. replace the entire handle assembly with the appropriate replacement part indicated in the table below. overnight. 7: These curves are for balancing contractors’ use when balancing an HVAC system. Gbv-s & Gbv-t Five Turn Circuit Balancing Valves Fig. 8. To return the valve to its preset “balanced” position. the locking memory stop should be set. (Fig. OR TIGHTEN VALVES. up stream. set the valve to its fully open position (5.M. If for any reason. DO NOT APPLY EXCESSIVE FORCE WHEN REOPENING THE VALVE – OPEN ONLY UNTIL THE VALVE STOPS TURNING UNDER “HAND TIGHT” CONDITIONS.P. please refer to Fig. Low Pressure Port (blue) High Pressure Port (orange) memory settinG: • Remove protective cap from metering ports (1⁄4" NPT connection). The memory has now been set. See next page for Fig. may occur when the probe is removed. CLOSE. Do not try to take it off the valve. The hose with orange fitting.M. GBV-T trouBLESHootInG: Symptom 1. The seat o-ring has been deformed due to overheating during soldering. 8: These curves show the pressure drop across the balancing valves and are for use in valve sizing. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. If solder joint .the connection is not sufficiently tight. Remove the handle / stem assembly and replace with the appropriate replacement part indicated in Table 1. please refer to Fig. 2. being careful not to over-tighten. 7. Re-solder the connection and recheck for leakage. Remove the handle / stem assembly and replace with the appropriate replacement part indicated in Table 1. For “pressure drop / flow” curves – required for system balancing. www. Remove and reinstall a new valve.12 181 . Gbv-s & Gbv-t Fig. Valve is leaking: • At the bonnet / body joint • At the pipe connection Bonnet o-ring has been damaged.GruVLoK InStALLAtIon And ASSEMBLY Five Turn Circuit Balancing Valves Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.com GL-7. Valve does not shut off completely when closed (hand tight). If threaded . 7. Likely cause Solution Tighten and re-check for leakage.the joint has failed. For “pressure drop / flow” curves – required for system balancing. please refer to Fig. GBV-S Fig. or was not soldered properly.anvilintl. 8: These curves show the pressure drop across the balancing valves and are for use in valve sizing. or the valve was over-tightened during installation and the valve body has cracked (fractured). Always support the piping to prevent excessive weight from compressing the hose and relaxing the braid tension. on flanged units. The braided hose sections must not be allowed to bend. Inspect for frayed or broken braid wires.com GL-6. one to prevent the hose from twisting and the other to tighten the coupling. Check system pressure and temperature and do not exceed recommended performance limits. The shipping sticks. maintenance The braided metal hose assembly should be inspected during routine maintenance to ensure there are no signs of external damage. refer to a Chemical Resistance Data table or contact your Anvil rep.GruVLoK InStALLAtIon And ASSEMBLY anvilflex™ fiG. Operation beyond design limits will result in premature failure. are to keep the braided metal hose assembly in its neutral end-to-end dimension during shipping and installation. A piping system. the shipping sticks should be removed. Use care when handling the braided metal hose assembly during transportation. Install the braided metal hose assembly with neutral face-to-face dimension as shown on the submittal drawing. or sweat end. If in doubt as to suitability. The maximum system test pressure must not exceed 150% of the maximum rated working pressure as shown. or when welding in the area of a braided metal hose assembly.anvilintl. The corrugated inner hose contains the fluid. The mating flanges should also straddle the centerline to avoid torque on the braided metal hose assembly. Do not place wrenches on the braided portion or the collar of the braided metal hose assembly. af21-GG. Groove x Groove Improper Installation Compressed www. The repetitive bending of a hose assembly to a radius smaller than the radius specified will result in early hose failure. which utilizes braided metal hose to absorb movement. 1 2 10 11 12 13 14 15 1 2 The corrugated metal hose alloy must be chemically compatible with the media in the piping system. storage. The utilization of lap joint flanges or pipe unions will minimize this condition. and installation. The flanges on a concentric increasing braided metal hose assembly have the bolt holes straddling the hose centerline. Always install the hose assembly so that the flexing takes place in only one plane—this being the plane in which the bending occurs.11 . If the braided metal hose assembly must be installed with an initial offset then the maximum allowable movement is reduced by the amount of the initial deflection. Use care not to torque the braided metal hose assembly while tightening the union. the braided metal hose assembly should be replaced. After installation. the braid is designed to take the stress of system pressurization and contain the core. or otherwise extend beyond their rated capabilities. Also inspect to ensure there is no damage to the hose. extreme care is necessary in ensure no weld spatter comes in contact with the braided hose sections. Groove x Groove Improper Installation Parallel Groove x Groove Proper Installation 3 4 5 6 7 8 9 182 To install a thread end braided metal hose assembly unions must be used. During system shutdown braided metal hose assembly should be examined to verify no thermal axial motion has occurred causing compression of the assembly. braided metal hose assemblies. must be properly anchored and/or guided. especially near the end fittings of the assembly. Verify that the movements of the system are within the design parameters of the braided metal hose assembly being installed. Avoid over bending. sag. It is recommended that two wrenches be used in making the union connection. Do not twist the hose assembly during installation when aligning the bolt holes in a flange or in making up pipe threads. Utilize sound geometric configurations that avoid sharp bends. -Gf & -ff Flex Connectors installation Avoid torque. Do not install a braided metal hose assembly compressed (bagged braid). Prevent out-of-plane flexing in an installation. When installing weld end. for guidance. deflect. In the event that such damage is found. Always provide sufficient length to prevent over bending and to eliminate strain on the hose assembly. Forged Steel and Ductile piping products against a wide range of environmental concerns. Teflon. brine and saltwater.. Did you know that Anvil can provide you with significant cost-savings for your underground piping applications? did you know. offer and warranty coated piping product solutions.11 183 . Anvil’s field-proven. bacteria and fungus. push down and release corrosive chemicals that attack your piping products. Anvil’s protective coatings are ideal for both internal and external applications. Let us help you prolong your piping product investment and save you money.. including soil stress. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories protect your products and your investment with anvil coatinGs. Powder and many more. corrosive soils. Nap-Guard.anvilintl.com GL-6. including: Nickel. CO2. including: • Natural Gas • Petroleum • Water and Sewage • Refineries • Petrochemical Plants Your drilling or recovery efforts stir up. harsh chemicals. Chrome.AnVIL SPEcIAL coAtInGS Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. cost-effective coatings are designed to protect all grades of Malleable. soil acids. Cast Iron. destroying their performance— and your investment. brine and saltwater. harsh chemicals. • Power Plants • Paper Mills www. Anvil International is the only manufacturer to stock. and alkalis. • Additional coatings — We offer other coatings as well. • corvel 1660 — Specially designed to protect the inside diameter of tubular goods from corrosive conditions such as H2S. Our coatings include: • Scotchcote 134 — A fusion bonded epoxy coating designed to resist wastewater. hydrocarbons. Anvil personnel meet with you to determine your piping preferences.anvilintl. 184 www. and compliance. Initially. (4) sets of drawings with tags and Bills of Materials of the included system components are sent to you. We may suggest modifications in arrangement. Preliminary prints are sent to you for revision or approval. contact your Anvil representative for more information. taking equipment location and any interferences into consideration. Also. Copies of the electronic data file of the project drawings are available at no extra charge. This brochure is an example of the finished product. We usually reduce fitting counts by 10%-15% by moving equipment whenever possible. There are many different types of services offered as extended: • BOM by component (pump. The project scope and fee is agreed upon in a Design Services contract. The drawings include a Bill of Materials with tags referencing the components in the mechanical room. the more savings can be realized.. construction. and pumps from contractor supplied flow diagrams. heat exchangers.com GL-6. The piping is color coded by service and is represented in 3-D with plan. Contact your Anvil representative for more information. mechanical drawings. chiller) or by system • Unique Tagging – adding unique tags to individual components • Air Handling Units – with associated ductwork • Single Line Routing – non-dimensional • Distribution Piping • Dimensioned Floor Penetrations • AWWA Piping . The more movement that is allowed. usually less than a foot.dESIGn SErVIcES anvil desiGn services offers both Basic and Extended Services. you can plan the mechanical room. your field supervisor can spend more time supervising and not calculating pipe lengths and pipe routing. and approved submittals and specifications. Piping drawings are then prepared to determine the most efficient pipe routing. The components can be grouped from the finished drawings for better workflow planning. equipment location. With Basic Services. accuracy. BASIc SErVIcES Anvil Design Services produces fabrication drawings of mechanical room piping 21⁄2" and larger including chillers. EXtEndEd SErVIcES: Extended Services include any scope beyond Basic Services.Field Survey • Hybrid Systems • Anything Else Upon approval. The preliminary drawings can be taken to coordination meetings with other trades to “reserve” space by “getting in” first. or product to attain the desired results. Piping layouts are carefully analyzed to determine whether further economies can be attained in the piping system.Total Scope • Commercial Piping • Oil Field Piping • Retrofit Projects . The plans and specifications are then interpreted in terms of economy. isometric. boilers. and elevation views.11 .. 7050 90 ELBOW.Fig.Fig.7051LR 45 ELBOW.5 4 4x2.5 GRVxGRV 2 14 4 GRVxTHD 1 15 2. RIGIDLOK GRVD.7700 GRUVLOK. RIGIDLOK GRVD. GRUVLOK.5 2.7061 REDUCING TEE.5 GRVxGRV 2 29 2. GRVD COUPLING.5 6 6 6 10x2. FLANGE ADAPT. GRVD STRAINER.7051LR GRUVLOK.com/Sharedcontent/Pdf/Literature_ProductBrochures/design_brochure. GRVD GRUVLOK.7072 6x5" GRVD CONC REDUCER GRUVLOK.SER.5 2.7001 GRUVLOK. GRVD BUTTERFLY VALVE.5 2.7050 GRUVLOK.5 2.7074 DESCRIPTION #2 290390014249 290390013522 290390016822 290390014801 290390013548 290390028645 290390030161 Qty TAG# SIZE END TYPE 1 1 2. 10'-0" 26 22 21 5 2 7 4 5 2 5 8 20 14 9 10 8 7 7 2 7 3 2 7 12 3 2 7 4 5 21 22 26 5 7 8 7 8 C L ELEV.SER. GROOVED SUCTION DIFF.7012 6x4" GRVD CONC REDUCER GRUVLOK.FIG. 10'-0" 7 2 7 5 15 C L ELEV.11 8'-1 7/8" 9'-0 1/8" 10'-4 3/8" 12'-10 3/8" 14'-0 1/2" 61 54 A M-1 PIPING PLAN VIEW 3/8" = 1'-0" 20'-4 1/2" 24'-2 1/2" 26'-5" 27'-11 1/2" 28'-7" 31'-7 1/2" 37'-10" 54 185 .7700 GRUVLOK.5 M-2 GRVxGRV 1 B 17 2.7800 GRUVLOK. 10'-0" 5'-5 3/16" 290390028413 290390020102 290390013563 290390014942 290390014363 290390013589 290390020126 290390014983 290390019065 290390014405 290390016962 290390029429 290390030302 290390016921 290390020110 290390028967 290390020114 290390029007 290390020118 C L ELEV. THRD TEE.7700 GRUVLOK.5 2 2 2.SER. THRD GRUVLOK.7260 GRUVLOK.Fig.Fig. FLEX GRVD.5 GRVxGRV M-2 18 2 20 4 GRVxGRV 6 22 2 THDxGRV 4 24 2.Fig.7051LR 45 ELBOW.7401 COUPLING.5 GRVxGRV 1 30 6 GRVxGRV 1 31 6 GRVxGRV 1 35 6 GRVxGRV 1 37 6 GRVxGRV 1 38 6 GRVxGRV 1 39 6 GRVxGRV 1 40 6 GRVxGRV 1 41 6 GRVxGRV 1 42 6 GRVxGRV 1 43 6 GRVxGRV 2 44 6 GRVxGRV 1 45 6 GRVxGRV 1 46 6 GRVxGRV 1 47 6 GRVxGRV 1 48 6 GRVxGRV 4 49 6 GRVxGRV 1 50 10 GRVxGRV 1 52 10 GRVxGRV 1 53 10 GRVxGRV 6 GRVxGRV 1 63 6 GRVxGRV 1 64 GRVxGRV 2 65 6 GRVxGRV 1 67 6 GRVxGRV 1 68 6 6 GRVxGRV 2 69 10 GRVxGRV 1 70 10 GRVxGRV 1 71 10 GRVxGRV 1 72 6 GRVxGRV 1 73 6 GRVxGRV 1 74 GRVxGRV 6 1 77 GRVxGRV 6 1 78 GRVxGRV 6 1 79 GRVxGRV 6 8 82 6'-8 7/8" 70 C L ELEV.Fig.7401 COUPLING. GRUVLOK. PART# GRUVLOK. GROOVED 10x6" GRVD CONC REDUCER GRUVLOK.Fig. GROOVED GRUVLOK. GRVD GRUVLOK. GROOVED 45 ELBOW. 4x2.5 GRVxGRV 2 13 2. GRVD STRAINER.Fig.Fig.SER. GRUVLOK.Fig.7072 GRUVLOK.Fig.7072 GRUVLOK. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories For a full-size printed brochure with systems coded by color contact your local Anvil representative and ask for Item #105 or visit http://www. GROOVED COUPLING. GRVD 3DTY VALVE.7250 DESCRIPTION #1 BUTTERFLY VALVE.Fig.7060 TEE.Fig.Fig.7060 GRUVLOK.Fig. FLANGE ADAPT. 8'-6 1/8" 54 57 C L ELEV.7401 GRUVLOK.7001 GRVD. 11'-0" 5 2 2 7 10 5 17 7 5 16 54 54 51 54 32 33 32 49 36 32 32 33 32 32 65 51 52 48 62 32 33 32 45 66 54 72 1 7 10 7 18 7 7 11 5 8 5 7 12 10 7 12 11 14 56 55 54 32 32 33 12 11 11 60 54 59 54 59 54 58 32 50 32 35 32 38 60 13'-10 15/16" 13'-6 5/8" 12'-7" 54 60 54 59 54 65 54 32 36 59 B-1 B-2 C L ELEV.Fig.Fig. GRUVLOK.722G GRUVLOK.7700 GRUVLOK.7012 GRVD. RIGIDLOK GRVD.7012 GRVD.5x2" GRVD CONC REDUCER GRUVLOK.Fig.anvilintl. GRVD COUPLING. 8'-1 5/8" 56 54 55 54 57 54 53 47 46 71 C L ELEV. TEE. GRVD GRUVLOK. RIGIDLOK GRVD.5 GRVxGRV 2 6 2.Fig. GRVD GRUVLOK.7012 GRVD. 10'-0" C L ELEV.dESIGn SErVIcES Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.Fig.5" GRVD CONC REDUCER CAP.7074 CAP.5 GRVxGRV 2 9 2. 11'-0" C M-2 16'-3 15/16" 17'-8 1/16" 19'-7 13/16" 23'-2 7/16" 24'-6 9/16" 26'-6 5/16" 3'-8 15/16" 3'-10 11/16" 5'-4 9/16" 6'-8 3/4" 7'-8 7/8" 8'-3" 10'-3 3/4" 5'-7 5/8" 7'-1 7/8" HX-1 HX-2 1'-2 1/2" 2'-4 11/16" www.com GL-6. FLEX GRVD.5 2.Fig. GRUVLOK.Fig. GROOVED SUCTION DIFF.5 6 10 6 10 6 6x5 6 PART# GRUVLOK.7012 GRVD.Fig.5x2 2.7401 GRUVLOK.7072 GRUVLOK. GRVD BUTTERFLY VALVE.Fig.5 GRVxGRV 2 3 2. GRVD 90 ELBOW.Fig.pdf PIPE FITTINGS PIPE LENGTH 5'-4 7/8" 6'-2 3/4" 4 1/4" 1'-8 13/16" 4'-7 3/8" 10 5/16"(FIELD FIT) 8'-7 1/4" 1'-0 7/16" 1'-8 7/8" 1'-3 1/8" 6" 6"(FIELD FIT) 6" 1' 4'-5 1/8" 1'-6 5/16" 3'-2 3/4" 4 5/8" 1'-5 5/16" 5'-10" 4'-4 7/8" 4'-2 3/8" 3'-5 1/8" 1'-3 11/16" 2'-4 1/4" 1'-3 1/2" 17'-7 1/8" 12'-11 1/8" 4'-9 15/16" 11 3/4" 2'-9 3/16" 4'-0 9/16" 1'-0 7/16" 2'-8 7/8" 2'-11 3/8" 2'-1 5/8" 7'-1 3/4" 6'-11 1/4" 1'-11 5/8" 7'-5 1/4" 25'-4 7/8" 17'-7 1/4" 4'-7 1/4" 4'-9 3/4" 5'-10 1/4" 6'-0 3/4" 1'-9 5/8" 1' Qty 10 27 32 6 4 4 4 2 6 2 6 4 73 8 18 2 22 2 2 7 3 1 5 2 2 24 2 2 2 2 8 TAG# 2 5 7 8 10 11 12 19 21 23 26 28 32 33 36 51 54 56 57 59 60 62 66 75 76 80 83 84 86 87 90 SIZE 2.anvilintl. 8'-6 1/8" 36 36 32 43 33 6'-11 1/8" 32 32 VALVES Qty 8 2 2 4 2 12 1 4 2 2 TAG# 4 25 27 34 55 58 61 81 85 89 SIZE 2. GROOVED P-2 36 32 69 32 66 54 59 66 32 36 69 66 54 59 P-1 C L ELEV.5 GRVxGRV 1 2.FIG.Fig.5 2. GRVD COUPLING.SER.7060 TEE.Fig. FLANGE ADAPT. GROOVED BUTTERFLY VALVE.Fig.Fig.Fig. COUPLING. GRUVLOK.5 10 10 10 10x6 10 10 10x6 6 6 6 4 6x4 5 6x5 6 DESCRIPTION #1 90 ELBOW.7076 2.7050 GROOVE-O-LET GRUVLOK.758 GRUVLOK. GROOVED CHECK VALVE.Fig. FLANGE ADAPT.5 2.5 D GRVxGRV 1 16 2. GRUVLOK. 10'-0" P-4 54 70 54 66 32 79 32 32 36 42 32 33 32 P-3 C L ELEV.7250 GRUVLOK. FLANGE ADAPT. 722G GRUVLOK.7401 GRUVLOK.Fig.Fig.Fig.Fig.7012 GRUVLOK.Fig. COUPLING. FLEX GRVD.7050 GRUVLOK.7051LR GRUVLOK.7072 GRUVLOK.Fig.SER.7060 GRUVLOK. DESCRIPTION #2 290390014249 290390013522 290390016822 290390014801 290390013548 290390028645 290390030161 290390028413 290390020102 290390013563 290390014942 290390014363 290390013589 290390020126 290390014983 290390019065 290390014405 290390016962 290390029429 290390030302 290390016921 290390020110 290390028967 290390020114 290390029007 290390020118 54 59 54 66 32 79 32 36 32 33 32 32 71 33 32 32 32 36 32 44 77 80 81 80 80 58 80 82 80 85 82 80 84 42 32 43 36 32 32 44 78 80 81 80 82 46 47 80 58 80 80 84 83 83 82 80 85 C M-1 COND NO SC For a full-size printed brochure with systems coded by color contact your local Anvil representative and ask for Item #105 or visit http://www.5 GRVxGRV 4 1/4" 2 1 47 6 GRVxGRV 12'-11 1/8" 9 2. GROOVED PIPE FITTINGS Qty 10 27 32 6 4 4 4 2 6 2 6 4 73 8 18 2 22 2 2 7 3 1 5 2 2 24 2 2 2 2 8 TAG# 2 5 7 8 10 11 12 19 21 23 26 28 32 33 36 51 54 56 57 59 60 62 66 75 76 80 83 84 86 87 90 VALVES 8 2 2 4 2 12 1 4 2 2 4 25 27 34 55 58 61 81 85 89 Qty TAG# SIZE PART# 2.7072 GRUVLOK. GRVD BUTTERFLY VALVE. GRVD TEE.5 10 10 10 10x6 10 10 10x6 6 6 6 4 6x4 5 6x5 6 PART# GRUVLOK.7076 GRUVLOK.5 GRVxGRV 1'-8 7/8" 1 17 63 6 1 GRVxGRV 2'-8 7/8" 2.Fig. 4x2. RIGIDLOK GRVD. RIGIDLOK GRVD. GRVD.5 4 4x2.Fig. GROOVED CHECK VALVE. FLANGE ADAPT.7012 GRUVLOK. COUPLING. FLANGE ADAPT.SER.SER.7250 GRUVLOK. THRD TEE.5 GRVxGRV 5'-4 7/8" 1 1 45 6 GRVxGRV 1'-3 1/2" 3 2. GRVD TEE.7074 GRUVLOK. RIGIDLOK GRVD. GROOVED BUTTERFLY VALVE.Fig.Fig.5 2.7050 GRUVLOK.7060 GRUVLOK.7012 GRUVLOK. GRVD REDUCING TEE.5 2.Fig.com GL-6.anvilintl.7800 GRUVLOK.5x2 2. 6x5" GRVD CONC REDUCER GRVD.5 GRVxGRV 1'-8 13/16" 2 1 48 6 GRVxGRV 4'-9 15/16" 2.SER. GROOVED 10x6" GRVD CONC REDUCER CAP.Fig.Fig.7012 GRUVLOK.Fig.758 GRUVLOK. FLANGE ADAPT.5 6 6 6 10x2.FIG. GRVD 90 ELBOW.Fig.7700 GRUVLOK. GRVD COUPLING. 45 ELBOW.5 GRVxGRV 1' 6 2 69 GRVxGRV 1'-11 5/8" 1 30 6 GRVxGRV 4'-5 1/8" 10 1 70 GRVxGRV 7'-5 1/4" 1 31 6 GRVxGRV 1'-6 5/16" 10 1 71 GRVxGRV 25'-4 7/8" 1 35 6 GRVxGRV 3'-2 3/4" 10 1 72 GRVxGRV 17'-7 1/4" 1 37 6 GRVxGRV 4 5/8" 6 1 73 GRVxGRV 4'-7 1/4" 1 38 6 GRVxGRV 1'-5 5/16" 6 GRVxGRV 4'-9 3/4" 1 74 1 39 6 GRVxGRV 5'-10" GRVxGRV 5'-10 1/4" 6 1 77 1 40 6 GRVxGRV 4'-4 7/8" GRVxGRV 6'-0 3/4" 6 1 78 1 41 6 GRVxGRV 4'-2 3/8" GRVxGRV 1'-9 5/8" 6 1 79 1 42 6 GRVxGRV 3'-5 1/8" GRVxGRV 1' 82 6 8 1 43 6 GRVxGRV 1'-3 11/16" DESCRIPTION #1 BUTTERFLY VALVE. GRVD.Fig.5 GRVxGRV 6" 6 1 68 GRVxGRV 6'-11 1/4" 2 29 2.7700 GRUVLOK.7051LR GRUVLOK.FIG.7401 GRUVLOK.Fig.5 2 2 2. GRVD STRAINER.7260 GRUVLOK.7061 GRUVLOK. GRVD GROOVE-O-LET COUPLING. FLEX GRVD. 45 ELBOW. FLANGE ADAPT.dESIGn SErVIcES PIPE Qty TAG# SIZE END TYPE PIPE LENGTH Qty TAG# SIZE END TYPE PIPE LENGTH 2 44 6 GRVxGRV 2'-4 1/4" 1 2. GROOVED 45 ELBOW.Fig.Fig.7001 GRUVLOK.5 GRVxGRV 4'-7 3/8" 2 13 4 49 6 GRVxGRV 11 3/4" GRVxTHD 10 5/16"(FIELD FIT) 4 2 14 1 50 10 GRVxGRV 2'-9 3/16" 2.Fig.5 GRVxGRV 1'-0 7/16" 1 16 1 53 10 GRVxGRV 1'-0 7/16" 2. GROOVED 90 ELBOW.Fig.5 2.Fig.7060 GRUVLOK.11 .Fig. GRVD COUPLING. GROOVED COUPLING.7250 SIZE 2.7072 GRUVLOK.7401 GRUVLOK.5 2.Fig.7012 DESCRIPTION #1 90 ELBOW.com/Sharedcontent/Pdf/Literature_ProductBrochures/design_brochure.7074 GRUVLOK.SER. FLANGE ADAPT. GRVD COUPLING.5 6 10 6 10 6 6x5 6 GRUVLOK.7700 GRUVLOK.5 GRVxGRV 6'-2 3/4" 2 1 46 6 GRVxGRV 17'-7 1/8" 6 2.Fig. GRVD 3DTY VALVE.Fig.7050 GRUVLOK.Fig.Fig. RIGIDLOK GRVD.5" GRVD CONC REDUCER CAP.Fig. THRD 2.anvilintl.5 2.7072 GRUVLOK.7051LR GRUVLOK.Fig. GRVD BUTTERFLY VALVE.7700 GRUVLOK.pdf 186 www.5 GRVxGRV 8'-7 1/4" 1 15 1 52 10 GRVxGRV 4'-0 9/16" 2. GRVD STRAINER. GROOVED SUCTION DIFF.5 2.Fig. TEE.5x2" GRVD CONC REDUCER GRVD.7001 GRUVLOK. GROOVED SUCTION DIFF.7401 GRUVLOK.5 2. 6x4" GRVD CONC REDUCER GRVD.5 GRVxGRV 1'-3 1/8" 1 18 6 1 64 GRVxGRV 2'-11 3/8" GRVxGRV 6" 4 2 20 6 2 65 GRVxGRV 2'-1 5/8" THDxGRV 6"(FIELD FIT) 2 6 22 6 1 67 GRVxGRV 7'-1 3/4" 4 24 2. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories 51 7 .anvilintl.11 187 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.com GL-6.dESIGn SErVIcES 16 17 5 2 5 7 51 10 7 18 2 5 5 7 10 15 7 1 4 6 7 5 7 8 7 10 7 9 21 7 4 5 3 26 5 22 23 22 21 26 5 4 5 25 5 24 28 14 7 8 2 7 11 7 4 7 29 5 2 7 8 2 7 11 7 4 7 29 5 2 7 12 11 IN 7 8 7 5 8 5 3 7 21 22 4 6 5 7 8 7 2 7 10 7 9 21 26 26 5 22 23 22 21 26 5 4 5 25 5 24 28 14 7 12 11 IN 2 26 5 5 2 5 2 4 7 5 7 21 22 13 7 12 13 20 28 24 5 27 5 12 20 28 24 5 27 5 60 D HOT WATER ISO NO SCALE 32 45 33 32 54 65 32 32 32 59 54 32 66 58 32 36 49 32 36 32 58 32 34 32 90 68 32 76 M-1 32 33 48 32 33 32 33 36 32 58 32 32 49 32 58 32 34 32 67 67 76 32 90 32 36 32 49 90 DENSER WATER ISO CALE 32 36 32 49 90 www. .......... 196-197 Coupling Working Pressure Rating on Light Wall Roll Grooved Steel Pipe...................................................................... 204-205 72 Drafting Symbols for Gruvlok® Piping Systems...............189 Specified Bolt Torque................ 7240 Order Form ...........................................................................................................209 Cut Groove Specifications...........................................................................................................................211 59 Roll Groove End Guard® Specifications .. 213 32 59 54 54 57 54 53 54 80 81 B M-1 CHILLED WATER ISO NO SCALE 80 82 80 80 58 80 82 188 GL-7...............210 Cut Groove End Guard® Specifications 54 ..............................................192 Gasket Grade Index............................................................ 212 32 32 36 66 32 73 32 69 32 74 36 69 32 64 55 56 59 54 54 54 59 32 58 32 54 60 Fig................................................................. 190 Design Factors .............................................................................................................................................................................199 Coupling Working Pressure Rating on 304 & 316 Stainless Steel Roll Grooved Pipe ............ 201-203 Coupling Flexibility ........................................................................................................................................................................................................................207-208 Roll Groove Specifications ........................................... 193 Gruvlok Gasket Recommendations .............................200 Pipe Support ...................................................191 Gruvlok Gasket-Styles ....tEcHnIcAL dAtA technical data tABLE oF contEntS Gruvlok® Lubricants ..........198 Coupling Working Pressure Rating on Roll Grooved ISO Steel Pipe............................. 190 Gruvlok Flow Control Components ....................................................12 87 86 80 89 80 www.......211 54 66 Gruvlok CTS Copper System Specifications ....................................................................com ..anvilintl..................193-195 Movement-Applications...........................................................206 32 32 66 54 32 52 30 54 54 63 58 32 36 54 90 32 33 32 36 31 56 55 32 57 90 36 32 36 32 80 81 40 80 82 80 87 86 41 37 32 32 36 32 38 32 36 32 32 33 32 34 90 32 34 32 58 32 90 39 61 36 36 32 65 32 59 54 62 35 54 60 32 58 32 50 Pipe Preparation .......... to become more susceptible to leakage.172.tEcHnIcAL dAtA GruVLoK® XtrEMEtM LuBrIcAnt Gruvlok® Xtreme™ Lubricant has been developed for use with Gruvlok couplings in services where improved lubrication is beneficial. and for the lubrication of gaskets on HDPE couplings. This lubricating film enhances our flexible coupling gasket’s ability to compensate for axial. The quick drying quality of the lubricant eliminates lubricant drips caused by over lubrication. tasteless and odorless grease made from Silicone Oil and other ingredients that are safe to ingest. Lubrication of the pipe end and gasket will help the gasket to adjust into the proper sealing position during temperature cycles.177. high temperature applications above 150°F (65. and does not support bacterial growth. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. This is particularly important at higher temperatures where oxidizing agents in the piping system become more aggressive. It is water-soluble. lubrication of gaskets in copper systems.8°C to 65. 21. It is NSF approved for use with potable water. but also on the inside. This lubricant has an operating temperature range from -65°F to 400°F (-53.F. 54 9 GruVLoK® QuIcK drY LuBrIcAnt Gruvlok® Quick Dry Lubricant is a fast drying lubricant that has been developed for applications where the piping system is exposed. non-petroleum based oils to ease spreading of the lubricant. applications where increased pipe joint flexibility is needed. Lubrication on the inside of the gasket is easily accomplished by turning the gasket inside out and applying the lubricant. well exceeding the temperature range of Gruvlok gaskets. It is NSF approved for use with potable water.1550 (Incidental Food Contact). Gruvlok Lubricant is water soluble. thereby eliminating water wash-out and it will not dry out in the absence of water. GruVLoK® LuBrIcAnt Gruvlok® Lubricant is the standard lubricant that has been provided for use with Gruvlok products for years. it is required that the gasket be lubricated not only on the outside. non-flammable. The temperature change will also force the gasket to slightly reposition itself. In applications where pipe movement is expected. it can be used with EPDM. This lubricant is easy to apply by brush or hand. Gruvlok Xtreme Lubricant will maintain it’s lubricating properties at lower temperatures allowing a properly lubricated pipe end and gasket (assembly) to reposition itself during temperature cycles. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok® lubricants • Gruvlok Xtreme Lubricant is the only Gruvlok lubricant that is to be used with Gruvlok couplings and gaskets in HDPE and copper piping systems. Gruvlok Quick Dry Lubricant is non-corrosive. The lubricant on the interior of the gasket will act to improve the chemical resistance of the gasket material by providing a thin lubricant barrier between the piping system fluid and the gasket surface. cAutIon: HDPE pipe requires the use of Gruvlok Xtreme Lubricant and should not be used with Gruvlok Lubricant. and it quickly dries to a thin film when in contact with air. Gruvlok® XtremeTM Lubricant is a Teflon® fortified white. ®Teflon is a registered trademark of Dupont. however. transverse and rotational pipe movements. • For high temperature service and copper systems. Since it is formulated from a non-hydro carbon base. However. thereby lowering the sealing force on the gasket sealing lips. non-toxic.R. • In low temperature applications the gasket will shrink. The lubricant is made from a water emulsion that is non-toxic.12 189 . allowing a properly lubricated pipe end and gasket assembly to re-position itself during temperature cycles.878 & 21. www. It is sanctioned by the FDA under C. This lubricant is waterproof.com GL-7. This lubricant is acceptable for most applications. It is not to be used with Silicone gaskets. and will not impart taste or odor. Gruvlok Xtreme Lubricant will maintain it’s lubricating properties at higher temperatures. It’s low temperature capability and lubricity ensure a highly reliable connection. The service temperature range for this lubricant is from 0° F to 150° F (-17. cAutIon: Silicone based lubricants are not allowed in some facilities. If necessary. with small cuts or damage.8°C to 204°C). and is NSF approved for use with potable water. the Gruvlok Xtreme Lubricant and Gruvlok Quick Dry Lubricant are now available to improve the performance of the couplings and flanges in certain applications. This will cause pipe end sealing surfaces. Do not thin or mix with solvents. gasket chemical compatibility must still be considered. reapply lubricant prior to assembly. non-corrosive. as with the normal installation of a Gruvlok gasket. proper lubrication of the gasket’s exterior assists the gasket into the proper sealing position as pipe system movement occurs. Nitrile and Fluoroelastomer gasket materials. There are five primary applications where the Xtreme Lubricant will provide increased benefits: low temperature applications below 32°F (0°C). non-flammable.anvilintl.6°C). it will not impart taste or odor.6°C) and may be used with all Gruvlok gasket material grades. • The Gruvlok Xtreme Lubricant has been formulated from low viscosity. 7010 are the flexible couplings provided in the Gruvlok product line. and (2) the gap between pipe ends joined by the coupling. The amount of angular flexibility varies for each coupling size and type. The available linear movement provided by Standard Gruvlok couplings is shown below: anGular movement: FLEXIBLE couPLInG AnGuLAr MoVEMEnt Designed-in clearances allow limited deflection of the pipe joint within the coupling. Fig. without introducing eccentric loads into the coupling joint. and coupling tolerances. 11 7 Specified Bolt Torque * Ft. 3 1 5 3 7 MEtrIc SPEcIFIEd BoLt torQuE Bolt Size mm Wrench Size In. notE: Use specified bolt torque unless otherwise indicated on product installation pages. θ ⁄32" ⁄32" 1 3 ⁄16" ⁄16" rIGId couPLInGS Gruvlok rigid couplings Fig.tEcHnIcAL dAtA specified bolt torQue Specified bolt torque is for the oval neck track bolts used on Gruvlok couplings and flanges. 7000. Movement is possible in the Gruvlok coupling due to two factors: (1) designed-in clearance between the key of the coupling and the groove diameter and groove width. The nuts must be tightened alternately and evenly until fully tightened. over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. Therefore. Under torquing the bolts may result in lower pressure retention capabilities. The values account for pipe. cAutIon: Proper torquing of coupling bolts is required to obtain specified performance. The following information on movement applies to these flexible couplings.-Lbs. Pipe joint separation may result in significant property damage and serious injury. Wrench Size mm Specified Bolt Torque * N-m ⁄8 ⁄2 ⁄8 ⁄4 ⁄8 ⁄16 ⁄8 30-45 80-100 100-130 130-180 180-220 200-250 225-275 250-300 M10 M12 M16 M20 M22 M24 16 22 24 30 34 36 40-60 110-150 135-175 175-245 245-300 270-340 11⁄16 1 ⁄4 1 17⁄16 15⁄8 113⁄16 2 1 11⁄8 11⁄4 * Non-lubricated bolt torques * Non-lubricated bolt torques desiGn factors MoVEMEnt: Each flexible design Gruvlok coupling can provide for pipe system movement up to the design maximum for the specific size and type of coupling being utilized. joint leakage and pipe joint separation. 7400. Represents Linear Movement Capabilities LInEAr MoVEMEnt Sizes 1" through 31⁄2" 4" though 24" Roll Groove Pipe Cut Groove Pipe 1 3 The maximum available angular θ/2 movement of Gruvlok flexible couplings on roll groove joints is shown in the performance data for each coupling. 7004 HPR are designed to provide a joint with the attributes of a welded or flanged connection.12 . linear movement: FLEXIBLE couPLInG LInEAr MoVEMEnt Linear movement is accommodated within the coupling by allowing the pipe ends to move together or apart in response to pressure thrusts and temperature changes.anvilintl. battery strength and operational variations. 7001. 7003. these joints would remain in strict alignment and would resist deflection and linear movement during service. lower bend load capabilities.com GL-7. AnSI SPEcIFIEd BoLt torQuE Bolt Size In. CAUTION: Use of an Impact wrench is not recommended because the torque output can vary significantly due to many variables including air pressure supply. groove. 190 www. 7401 and Fig. FLEXIBLE couPLInGS Figs. 11 191 .anvilintl. 7401 Rigidlok and Fig. The Gruvlok® Series 7800 Check Valve is full waterway valve and can be stacked directly to the Series 7700 Butterfly Valve. With the combination of the Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok® flow control Anvil has put together a complete array of Gruvlok components necessary to provide pump protection for HVAC and industrial piping needs. 7250 Suction Diffuser and Fig. HorIZontAL SPLIt cASE PuMP VErtIcAL SPLIt cASE PuMP End SuctIon PuMP www. 7260 Tee Strainer complete the Gruvlok® pump protection package.com GL-6. 7001 Standard coupling. The Series 7700 Gruvlok® Butterfly valve has superior flow characteristics. flex connectors can be eliminated thus reducing cost.tEcHnIcAL dAtA Components Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. The Fig. tEcHnIcAL dAtA Gruvlok Gasket-styles Gruvlok offers a variety of pressure responsive gasket styles. Each serves a specific function while utilizing the same basic sealing concept. Proper installation of the gasket compresses the inclined gasket lips on the pipe O.D., forming a leak tight seal. This sealing action is reinforced when the gasket is encompassed and compressed by the coupling housings. The application of internal line pressure energizes the elastometric gasket and further enhances the gasket sealing action. “c” style The “C” Style cross section configuration is the most widely used gasket. It is the gasket style provided as standard in many Gruvlok Couplings (Fig. 7000, 7001, 7003, 7004HPR, 7307, 7400 and 7401). Grade “E” and “T” are standard grades while other grades are available for special applications. rouGhneck® This “C” style gasket is similar in appearance and design to the Standard gasket but is only used with Fig. 7005 Roughneck Couplings and Fig. 7305 HDPE Couplings. The Roughneck gasket is wider, which allows for minor pipe end separation as line pressure sets the grippers into the plain end pipe. end Guard™ The projecting rib fits between the ends of lined pipe to prevent damage to unprotected pipe ends during coupling joint assembly. The E.G. gasket is provided as standard with the Fig. 7004 E.G. Coupling. Grade “E” and “T” gaskets are available. flush Gap™ Designed to prohibit contaminates from building up in the gasket cavity. The centering rib fits flush over the gap between the two pipe ends thus closing off the gasket cavity. It can be used with Fig. 7000, 7001, 7400 and 7401 Couplings for many applications. Recommended for use in dry fire protection systems. reducinG couplinG The centering rib allows for pipe positioning and serves to keep the smaller pipe from telescoping during installation. Used only with the Fig. 7010 Reducing Coupling. flanGe A specially designed gasket for the Fig. 7012, 7013 and 7312 Flange provides for a reliable seal on both the pipe and the mating flange. sock-it® Used in Sock-It fittings only, this pressure energized gasket provides a leak-tight seal on plain end seal pipe. Available in Grade “E” material only. clamp-t™ These gaskets conform to the curved exterior of the pipe to provide a pressure responsive seal. This unique design is only used with Fig. 7045, 7046 Clamp-T and Fig. 7047, 7048, and 7049 Clamp-T Crosses. 192 www.anvilintl.com GL-6.11 tEcHnIcAL dAtA VLOK GRU The lists are provided as an aid in selecting the optimum gasket grade for a specific application to assure the maximum service life. The recommendations have been developed from current information supplied by manufacturers of the elastomers, technical publications, and industry applications. The information supplied should be considered as a basis for evaluation but not as a guarantee. Selection of the optimum gasket grade for a specific service requires the consideration of many factors; primarily temperature, fluid concentration, and continuity of service. Unless otherwise noted, all gasket recommendations are based on 100°F (38°C) maximum temperature service condition. Where more than one gasket grade is shown, the preferred grade is listed first. Combinations of fluids should be referred to an Anvil Representative for an engineering evaluation and recommendation. In unusual or severe services, gasket materials should be subjected to simulated service conditions to determine the most suitable gasket grade. Gasket recommendations apply only to Gruvlok gaskets. Contact an Anvil Representative for recommendations for services not listed. These listings do not apply to Gruvlok Butterfly Valves. All Gruvlok products marked with UL/ULC Listed, FM approved VdS and/or LPC symbols are Listed/Approved with EPDM material. For other Listed/Approved materials, please contact an Anvil Representative for more information. Gasket Grade index StAndArd GASKEtS Grade Temp. Range -40°F to +230°F (-40°C to 110°C) -40°F to +250°F (-40°C to 121°C) Compound Color Code General Service Applications Water, dilute acids, alkalies, salts, and many chemical services not involving hydrocarbons, oils, or gases. Excellent oxidation resistance. NOT FOR USE WITH HYDROCARBONS Water, dilute acids, alkalies, salts, and many chemical Grade Temp. Range Compound +20°F to +300°F Fluoro (-20°C to Elastomer 149°C) -40°F to +350°F (-40°C to 177°C) SPEcIAL GASKEtS Color Code General Service Applications High temperature resistance to oxidizing acids, petroleum oils, hydraulic fluids, halogenated, hydrocarbons and lubricants Dry, hot air and some high temperature chemical services. Wet & Dry (oil free air) Pipe in Fire Protection Systems. For dry pipe systems, Gruvlok Xtreme™ Temperature Lubricant is required. E EP T EPDM Green O L Type A Blue EPDM Green services not involving hydrocarbons, oils, or gases. and Red Excellent oxidation resistance. NOT FOR USE WITH HYDROCARBONS Petroleum products, vegetable oils, mineral oils, and air contaminated with petroleum oils. NOT FOR USE IN HOT WATER SERVICES Silicone Red Gasket -20°F to +180°F Nitrile (-29°C to (Buna-N) 82°C) E Orange -40°F to +150°F Pre(-40°C to Lubricated 66°C) Violet Gasket recommendation listinG WAtEr & AIr Service Air, (no oil vapors) Temp. -40°F to 230°F (-40°C to 110°C) Air, (no oil vapors) Temp. -40°F to 350°F (-40°C to 177°C) Air, Oil vapor Temp. -20°F to 150°F (-29°C to 66°C) Air, Oil vapor Temp. 20°F to 300°F (-7°C to 149°C) Water, Temp to 150°F (66°C) Water, Temp to 230°F (110°C) Water, Acid Mine Water, Chlorine Water, Deionized Water, Seawater Water, Waste Water, Lime Gasket Grade E/EP L T O E/EP/T E E/T (E/EP/O) E/EP/T E/EP/T E/EP/T E/EP/T PEtroLEuM ProductS Service Crude Oil - Sour Diesel Oil Fuel Oil Gasoline, Leaded Gasoline, Unleaded* Hydraulic Oil JP-3, JP-4 and JP-5 JP-6, 100°F (38°C) Maximum Temp. Kerosene Lube Oil, to 150°F (66°C) Motor Oil Tar and Tar Oil Transmission Fluid —Type A Turbo Oil #15 Diester Lubricant Gasket Grade T T T T (O) T T/O O T T T T O O Where more than one gasket grade is shown the preferred gasket grade is listed first. Where the gasket grade is shown in parentheses, Contact an Anvil Representative for an engineering evaluation and recommendation. Specify gasket grade when ordering. Use Gruvlok lubricant on gasket. Check gasket color code to be certain it is recommended for the service intended. Unless otherwise noted, all gasket listings are based upon 100°F (38°C) maximum temperature service conditions. For services not listed, contact an Anvil Representative for recommendation. *Contact an Anvil Representative for service evaluation. vacuum service VAcuuM SErVIcE Size 1" - 12" (25 - 300mm) 11⁄2" - 12" (40 - 200mm) Vacuum Level 0" - 10" Hg 10" - 29.9" Hg Gasket Recommendation Standard or Flush Gap Flush Gap LARGER SIzES: Contact an Anvil Representative for more information. www.anvilintl.com GL-6.11 193 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gasket Grade index & Gasket recommendation tEcHnIcAL dAtA Gruvlok Gasket-recommendations cHEMIcAL SErVIcES Chemical Composition Gasket Grade cHEMIcAL SErVIcES Chemical Composition Gasket Grade cHEMIcAL SErVIcES Chemical Composition Gasket Grade Acetic Acid 50% Acetic Acid Glacial Acetone Acethlene Alkalis Alums Aluminum Chloride Aluminum Fluoride Aluminum Hydroxide Aluminum Nitrate Aluminum Salts Ammonia Gas, Cold Ammonia Liquid Ammonium Chloride Ammonium Fluoride Ammonium Hydroxide Ammonium Nitrate Amyl Acetate Amyl Alcohol Aniline Animal Fats Argon-Gas Arsenic Acid, to 75% Barium Carbonate Barium Chloride Barium Hydroxide Barium Nitrate Barium Sulphide Beet Sugar Liquors Benzene Benzene Sulfonic (Aromatic Acid) Benzoic Acid Benzyl Alcohol Benzyl Chloride Black Sulphate Liquor Bleach, 5% Active CI2 Borax Boric Acid Bromine Butyl Alcohol Butyl Stearate Butylene Calcium Bisulfate Calcium Bisulphide Calcium Bisulphite Calcium Carbonate Calcium Chloride Calcium Hydroxide (Lime) E/EP L/E/EP E/EP E/EP/T T/E/EP E/EP/T/O E/EP/T E/EP/T/O E/EP/O E/EP/T E/EP E/EP E/EP T/E/EP E/EP E/EP T/E/EP E/EP E/EP E/EP T L T/E/EP/O E/EP/T E/EP/T E/EP/T E/EP/O E/EP/T T O (E/EP) O E/EP E/EP T E/EP/O E/EP/O E/EP/T O E/EP/T E/EP T/O T/O T/O T/O E/EP/T E/EP/T E/EP/T Calcium Sulfate Calcium Sulfide Caliche Liquors Cane Sugar Liquors Carbitol Carbon Dioxide, Dry Carbon Dioxide, Wet Carbon Monoxide Carbon Tetrachloride Castor Oil Caustic Potash Caustic Soda Cellosolve Chlorine Dry Chlorinate Solvents Chlorobenzene Chlorobenzene Chloride Chlorobromomethane Chloroform Chrome Alum Chrome Plating Solutions Chromic Acid, to 50% Citric Acid Coconut Oil Cod Liver Oil Coke Oven Gas Copper Carbonate Copper Chloride Copper Cyanide Copper Sulphate Corn Oil Cotton Seed Oil Cresole, Cresylic Acid Creosote, Coal Tar Creosote, Wood Cupric Chloride Cupric Fluoride Cupric Sulphate Cychohexanol Diacetone Alcohol Dichlorobenzene Dichloroethylene Dioctyl Phthalate Epson-Salt Ethane Ethanolamine Ethyl Acetate Ethyl Alcohol E/EP/T E/EP/T E/EP/T T E/EP/T E/EP/T E/EP/T E/EP O T E/EP E/EP E/EP (O) (O) O O O O E/T O O E/EP/T T T T/O E/EP/T E/EP/T E/EP/T E/EP/T T T T/O (T/O) T/O E/EP/T E/EP/T E/EP/T O E/EP O O (E/EP) E/EP/T E/EP E/EP (E/EP) E/EP/T Ethyl-Chloride E/EP/T Ethyl Ether (T) Ethylene Chloride E/EP Ethylene Chlorohydrin E/EP Ethylene Diamine E/EP/T Ethylene Dichloride (Dichloroethane) O Ethylene Glycol E/EP/T Ethylene Oxide (E/EP) Ferric Chloride, to 35% E/EP/T Ferric Nitrate E/EP/T Ferric Sulphate E/EP/T Ferrous Chloride E/EP/T Fish Oils T Fluroboric Acid E/EP Fluorosilicic Acid E/EP Fly-Ash E/EP Formaldehyde E/EP/T Formamide E/EP/T Formic Acid E/EP/O Freon 11, 130°F (54°C) Max. T Freon 12, 113, 114, 115, 130°F (54°C) Max. T Fructose T Furfuryl Alcohol (E/EP) Glucose E/EP/T Glue T Glycerin E/EP/T Glycerol E/EP/T Glycol E/EP/T Heptane T Hexaldehyde E/EP Hexane T Hexylene Glycol T Hydrochloric Acid, to 36%, 75°F (24°C)-Max. E/EP Hydrochloric Acid, to 36%, 158°F (70°C)-Max. (O) Hydrofluoric Acid, to 75%, 158°F (70°C)-Max. (O) Hydrofluosilicic Acid T/E/EP Hydrogen Peroxide, to 50% E/EP/T/O Hydrogen Peroxide, to 90% (L/O) Hydroquinone T/O Iodine,-Wet E/EP Isoamyl Alcohol E/EP Isooctane T Isobutyl Alcohol E/EP Isopropyl Alcohol E/EP Lacquer (O) Lacquer Solvent (O) Lactic Acid T Lard Oil T Where more than one gasket grade is shown the preferred gasket grade is listed first. Where the gasket grade is shown in parentheses, Contact an Anvil Representative for an engineering evaluation and recommendation. Check gasket grade when ordering. Use Gruvlok lubricant on gasket. Unless otherwise noted, all gasket listings are based upon 100°F (38°C) maximum temperature service conditions. For services not listed, Contact an Anvil Representative for recommendation. Check gasket color code to be certain it is recommended for the service intended. 194 www.anvilintl.com GL-6.11 tEcHnIcAL dAtA Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories Gruvlok Gasket-recommendations (cont.) cHEMIcAL SErVIcES Chemical Composition Gasket Grade cHEMIcAL SErVIcES Chemical Composition Gasket Grade cHEMIcAL SErVIcES Chemical Composition Gasket Grade Latex (1% Styrene &-Butadiene) Lead Acetate Linseed Oil Lithium Bromide Magnesium Chloride Magnesium Hydroxide Magnesium Nitrate Magnesium Sulphate Malonyl Nitrile Mercuric Chloride Mercuric Cyanide Mercury Methyl Acetate Methyl Alcohol, Methanol Methyl Cellosolve (Ether) Methyl Chloride Methyl Ethyl Ketone Methyl Formate Methyl Isobutyl Carbinol Methyl Isobutyl Ketone Mineral Oils Naphtha, 160°F (71°C)-Max. Naphthalene 176°F Nickel Chloride Nickel Nitrate Nickel Plating Solution 125°F (52°C)-Max. Nitric Acid, to 10%, 75°F-(24°C)-Max. Nitric Acid, 10-50%, 75°F-(24°C)-Max. Nitric Acid, 50-86%, 75°F (24°C)-Max. Nitric Acid, Red Fuming Nitro Benzene Nitrous Oxide Octyl Alcohol Olive Oil Oxalic Acid Ozone Phenol (Carbolic acid) 300°F (149°C)-Max. Phenylhydrazine Phosphate Ester Phosphoric Acid, to 75% & 70°F (21°C)-Max. O E/EP/T T T/O E/EP/T E/EP/T E/EP E/EP/T E/EP/T E/EP/T E/EP/T E/EP/T (E/EP) E/EP/T E/EP (O) (E/EP) E/EP E/EP/T (E/EP) T O O E/EP/T E/EP E/EP E/EP O (O) (O) (O) E/EP T T E/EP E/EP O (O) E/EP E/EP/T Phosphoric Acid, to 85% & 150°F (66°C) Max. Photographic Solutions Potassium Bromide Potassium Carbonate Potassium Chloride Plating Solutions (gold, brass cadmium, copper, lead, silver, tin, zinc) Potassium Chromate Potassium Cyanide Potassium Ferricyanide Potassium Ferrocyanide Potassium Hydroxide Potassium Iodide Potassium Nitrate Potassium Permanganate, saturated, to 25% Potassium Sulphate Propanol Propyl Alcohol Propylene Glycol Pydraul 312C Pyroguard “C” &-“D” Pyroguard 55 Pyrrole Salicylic Acid Silver Cyanide Silver Nitrate Skydrol, 200°F (93°C)-Max. Skydrol 500 Phosphate Ester Soda Ash,-Sodium Carbonate Sodium Bicarbonate Sodium Bisulphate Sodium Bisulphite (black liquor) Sodium Bromide Sodium Chlorate Sodium Chloride Sodium Cyanide Sodium Hydroxide, to 50% Sodium Hypochlorite, to 20% Sodium Metaphosphate Sodium Nitrate O T E/EP/T E/EP/T E/EP/T E/EP T E/EP/T E/EP/T E/EP/T T E/EP/T E/EP/T E/EP E/EP/T E/EP E/EP/T E/EP/T O T E/EP E/EP E/EP/T E/EP E/EP L (L/E/EP) E/EP/T E/EP/T E/EP/T E/EP/T E/EP/T E/EP/T E/EP/T E/EP/T E/EP E/EP E/EP/T E/EP/T Sodium Peroxide E/EP Sodium Phosphate E/EP/T Sodium Silicate E/EP/T Sodium Sulphide E/EP/T Sodium Sulphite Solution, to 20% E/EP/T Sodium Thiosulphate, “Hypo” E/EP/T Soybean Oil T Stannous Chloride, to 15% E/EP/T/O Starch E/EP/T Stearic Acid T Styrene O Sucrose Solutions T Sulphur E/EP Sulphuric Acid, to 25%, 150°F (66°C)-Max. E/EP Sulphuric Acid, 25-50%, 200°F (93°C) Max. O Sulphuric Acid, 50-95%, 150°F-(66°C)-Max. O Sulphuric Acid, Fuming (O) Sulphuric Acid, Oleum (O) Sulphurous Acid (O) Tetrachloroethylene O Toluene O Tributyl Phosphate (E/EP) Trichloroethylene, 200°F-(93°C)-Max O Triethanolamine E/EP/T Trisodium Phosphate (E/EP/T) Turpentine 158°F-(70°C)-Max. T/O Urea E/EP/T Vegetable Oils T Vinegar T Vinyl Acetate (E/EP) White Liquor E/EP Xylene (Xylol)-158°F (70°C)-Max. O Zinc Sulphate E/EP/T Where more than one gasket grade is shown the preferred gasket grade is listed first. Where the gasket grade is shown in parentheses, Contact an Anvil Representative for an engineering evaluation and recommendation. Check gasket grade when ordering. Use Gruvlok lubricant on gasket. Unless otherwise noted, all gasket listings are based upon 100°F (38°C) maximum temperature service conditions. For services not listed, Contact an Anvil Representative for recommendation. Check gasket color code to be certain it is recommended for the service intended. www.anvilintl.com GL-6.11 195 tEcHnIcAL dAtA movement-applications thermal movement A sufficient amount of coupling joints must be provided to accommodate the calculated movement (expansion or contraction) in a pipe run or segment thereof . EXAMPLE: A 200 foot long straight run of 4" steel cut grooved pipe between anchor points . Minimum Temperature: 40° F (4 .4° C) . (at time of installation) . Maximum Oper . Temperature: 160° F (71 .1° C) . misaliGnment & deflection The angular movement capability of the Gruvlok coupling permits the assembly of pipe joints where the piping is not properly aligned. At least two couplings are required to provide for lateral pipe misalignment. Deflection (longitudinal misalignment) may be accommodated within a single coupling as long as the angle of deflection does not exceed the value shown in the coupling performance data for the particular size and coupling type. A pipe joint that utilizes the angular deflection capability of the Gruvlok coupling will react to pressure and thermal forces dependent upon the manner in which it is restrained. An unrestrained joint will react to these forces by straightening, thus reducing, if not eliminating, the deflection at the joint. If joint deflection has been designed into the pipe layout and must be maintained, then sufficient anchors must be provided to resist the lateral forces and hold the joint in the deflected condition. G M 200 FEET Thermal expansion tables show this system will expand a total of 1 .80" due to the temperature change . dESIGn QuEStIon: How many couplings are required to account for the thermal growth? AVAILABLE LInEAr MoVEMEnt PEr FLEXIBLE couPLInG: Using the table on page 190, we see that there is 0 .188" linear movement per coupling (4" Flexible Coupling) couPLInGS rEQuIrEd As indicated above, the total movement is 1 .80". Thus, the number of couplings is determined as follows: No . of Couplings = Tot . Movement / Avail . Movement per Coupling FOR OUR EXAMPLE: No . of Couplings = (1 .80") / (0 .187") = 9 .6, Therefore 10 couplings are needed L L G M The amount of deflection from pipe run centerline can be calculated utilizing the following equations: PoSItIon oF couPLInGS In order for the couplings to provide for the movement indicated by the above example, it would be necessary to install all couplings with the maximum gap between pipe ends. Conversely, if the thermal movement was contraction due to a reduction of system temperature, the coupling joints would have be installed with the pipe ends butted, thus accommodating the “shrink” of the pipe system. In either case the pipe run in question would have to be anchored at the proper locations to direct pipe system expansion or contraction into the coupling joints. As can be seen from the above example, the pipe end gap within the coupling joint must be considered when designing a grooved end pipe system to accommodate thermal movement. The couplings do not automatically provide for expansion and contraction of piping. WHErE: M = Misalignment (inches) G = Maximum Allowable Pipe End Movement (Inches) as shown under “Performance Data” 0 = Maximum Deflection (Degrees) from centerline as shown under “Performance Data” D = Pipe Outside Diameter (Inches) L = Pipe Length (Inches) 196 www.anvilintl.com GL-7.12 In systems where both are expected. vibration. Buried Pipe Systems www. The additional stress from the combined movement is therefore relieved. In the example above. pipe rotation will evenly distribute wear over the entire inner surface of the pipe. settlement. EXAMPLE: Before Pipe Rotation After Pipe Rotation Utilizing the rotational capability of the Gruvlok Coupling. For pipe rotation.anvilintl. two couplings were added to account for thermal expansion and the other couplings accommodate only the misalignment. the pipe life of a slurry or similar coarse material piping system can be extended. buried pipe systems where pipe laying conditions are subject to settlement. drAInAGE.: The flexible design of the Gruvlok coupling makes it ideal for use in a wide variety of systems in which random changes of the pipe direction can be accommodated by the Gruvlok coupling’s angular deflection capability rather than requiring the use of special fittings. and number of required couplings. The Gruvlok coupling will not allow for both maximum linear and maximum angular movement simultaneously. the couplings re-tightened.12 197 . additional joints may be required.com GL-7. or other similar movements. For Expansion notE: Fully deflected Joint Will not Allow For Linear Expansion. For Deflection L θ T=Nxθ R R R This example shows how to calculate the curve radius. will allow a limited capability for combined linear and angular movement. required pipe lengths. rotAtIonAL MoVEMEnt: Piping systems designed with Gruvlok Couplings can accommodate minor rotational movement from thermal expansion.) curve layout: Utilizing the angular deflection at each coupling joint curves may be laid out using straight pipe lengths and Gruvlok Couplings. Pitched drainage systems. the system must be shut down and internal pressure relieved. combined linear & anGular movement: The clearance in the grooved coupling joint. Pitched for Drainage The pipe may then be rotated one-quarter turn. and service resumed. Minutes) of each Coupling (See coupling performance data) T = Total Angular Deflection of all Couplings.tEcHnIcAL dAtA Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. If performed on a regular basis. Gruvlok Couplings should never be used as a continuous swivel joint. and exposed pipe systems laid on rough ground are but a few of the many types of pipe installations that present conditions where the functional capability of the Gruvlok coupling are useful. However. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories movement-applications (cont. R = L/(2 x Sin(0/2)) L = 2 x R x Sin(0/2) N = T/0 WHErE: N = Number of Couplings R = Radius of Curve (feet) L = Pipe Length (feet) 0 = Deflection from centerline (Degrees. Etc. BurIEd SYStEMS. A partially deflected joint will not provide full linear movement capability. A fully deflected coupling joint provides no linear movement capability. 9 31⁄2 90 4./DN(mm) O.000 609.120 0.120 0.083 0.250 0.312 0.3 21⁄2 65 2. 7013 Flange Fig.500 114.109 0.165 0.tEcHnIcAL dAtA couplinG workinG pressure ratinG on Light Wall Roll Grooved Steel Pipe GruVLoK couPLInG WorKInG PrESSurE rAtInG (PSI) on LIGHt WALL roLL GrooVEd StEEL PIPE Nominal Size In.11 .375 60.134 0. For coupling performance on standard wall steel pipe.6 400 16 18 16.D. 7004 HPR Fig.165 0.090 0.750 273.188 0.875 73.130 0. * Rating based on larger pipe size. Wall Thickness In.900 48.250 0./mm Nom.065 0.188 0.2 11⁄2 40 1. In.130 0. 7010* Reducing Fig.000 101. refer to individual Gruvlok Coupling performance listing.000 457.com GL-6.085 0.109 0. 7012 Flange Fig.1 250 10 10.120 0.148 0. 198 www.563 141.188 0. 7001 Standard Fig.9 350 14 14.109 0.083 0.085 0.3 5 125 150 5.6 0.156 0.500 88.3 6 6.065 0.250 0.134 0.083 0.083 0. Pipe Schedule Number Maximum Working Pressure (PSI*) Fig. including surge.065 0.090 0. 7400 Rigidlite Fig.134 0.000 406.250 0. 7003 Hingelok Fig.109 0. to which a joint should be subjected on pipe roll grooved to standard roll grooving specification with coupling properly assembled.3 200 8 8.315 33.anvilintl.4 11⁄4 32 1.6 4 100 4.000 508.0 80 3 3.625 168.156 0.312 0.1 300 12 12. 7000 Lightweight Fig.312 0.250 0.188 0.2 450 20 500 20.250 0.4 18.109 0.120 0.375 0.625 219.000 355.0 24 600 24.750 323.250 0.109 0.065 0.375 5 XL 10 5 XL 10 5 XL 10 5 XL 10 5 XL 10 5 XL 10 5 10 5 10 5 10 5 10 – 5 10 – 20 5 10 – 20 5 10 – 20 5 10 20 5 10 20 10 20 10 20 10 20 300 300 600 300 300 600 300 300 600 300 300 600 300 300 600 300 300 600 300 600 300 600 250 500 250 400 400 250 350 350 350 – – – – – – – – – – – – – – – – – – – – 500 300 750 500 300 750 500 300 750 500 300 750 500 300 750 500 300 750 500 750 500 750 400 500 350 500 500 300 400 400 500 250 350 350 400 200 350 350 400 125 250 275 125 175 275 100 175 100 300 75 300 – – – – – – 200 250 300 200 250 300 200 250 300 200 250 300 – – 200 300 200 250 150 200 200 150 200 200 250 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 500 300 800 500 300 800 500 300 800 – – 400 600 400 600 400 500 700 300 400 500 600 300 400 400 500 200 300 300 400 – – – – – – – – – – – – – – – – – – – – – 250 300 350 250 300 350 250 300 350 – – 200 300 200 300 200 300 350 150 250 300 300 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 200 300 300 200 300 300 200 300 300 – – 200 300 200 300 200 300 300 200 300 300 300 200 200 300 300 200 200 300 300 125 250 250 100 175 250 100 175 100 250 75 250 – – – – – – – – – 500 300 720 500 300 720 500 300 720 – – 500 720 400 500 350 500 500 300 400 400 500 250 350 350 400 200 350 350 400 – – – – – – – – – – – – 175 300 300 175 300 300 175 300 300 175 300 300 175 300 300 175 300 300 – – 175 300 175 300 175 300 300 175 175 300 300 – – – – – – – – – – – – – – – – – – – – – – – – – – 500 300 750 500 300 750 500 300 750 500 300 750 – – 500 750 400 500 350 500 500 300 400 400 500 250 350 350 400 200 350 350 400 125 250 275 100 175 275 100 175 100 250 75 250 Maximum line pressure.3 50 2 2.250 0. 7401 Rigidlok 25 1 1.660 42.109 0.180 0. 000 16.5 51.6 7.7 13.4 82.5 51.7 41.7 – – – 12.5 55.4 41.1 34.6 2.000 20 24 1.0 125 108.4 41.7 5.7 69.8 20.7 24.5 34.750 14.3 60. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories couplinG workinG pressure ratinG GruVLoK couPLInG WorKInG PrESSurE rAtInG (BAr) on roLL GrooVEd ISo SIZE StEEL PIPE Nominal Size In.8 2.7 20.7 – – – 27. 6 6 ⁄4 O.7 20.7 – – – 13.7 – – – 10.1 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 13. 7401 Rigidlok 25 1 1.2 1.8 2.1 20.8 20.D.8 20.2 82.2 20.0 4.7 41.9 12.8 5.7 20.2 24.7 34.5 51.D.2 24.4 6.2 82.5 51.7 20.7 51.5 17.4 20.7 20.0 – – – 24.8 20.2 6.7 13./DN(mm) O.7 34.6 114.7 69.3 8.7 20.0 165.anvilintl.000 24.5 69.1 200 250 300 350 400 450 500 600 159.1 24.9 12.0 8.625 168.4 20.7 12.7 12.7 27.3 – – – – – – 27.1 24.8 20. 4 4.2 24.7 35.0 3.8 20.8 20.com GL-6.8 20. 7003 Hingelok Fig.3 24.0 6.0 34.9 17.2 17.500 4.1 55.7 69.3 34.7 – – – 12.0 3.5 51.7 5.2 5.1 273.8 20.1 24.1 24.9 5.2 24.1 20.0 34.5 51.0 3.4 41.6 34.3 2.9 3.1 8.D.7 13.7 20.2 20.3 8.5 69. 1 133.625 219.2 – – – – – – – – – – – – – – – 12.2 5.8 17.3 2.9 17.660 1. 7000 Lightweight Fig.1 51.0 – – – 27.3 8.5 69.7 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 34.1 2.0 34.6 55.1 – – – 17.7 12.9 12.7 8.7 34.7 24.7 – – – 13.9 3.2 508.9 3. 7400 Rigidlite Fig.7 41.11 199 .3 73.000 20.7 20.1 55.2 6.375 2.5 69 – – – – – – 20.4 20.8 20.0 5.9 3.0 3.1 17.7 34.7 13.7 – – – 24.7 20.0 139.0 4.3 – – – – – – 20.2 20.9 3 3.6 5.7 20.1 2.5 17.7 20.7 51.7 20.9 17.7 – – – 13.6 17.1 2.7 150 133.2 34.7 41.7 20.7 24.1 20.2 5.2 20.7 69.8 5.6 2.5 51.000 18.2 27.5 55.7 8.1 51.1 20.7 6.3 8.9 3.7 69.7 69.4 41. to which a joint should be subjected on pipe roll grooved to standard roll grooving specification with coupling properly assembled.8 17.7 69.2 82.0 5.7 12.4 20.1 24.0 – – – 34.1 55.8 20. 7001 Standard Fig.7 20.7 51.7 5. 1 159.5 51.2 24.2 24.6 41.8 20.7 20.563 141.1 20.7 41.1 – – – 13.5 69.0 – – – – – – 24. 7012 Flange Fig.7 20.7 12.7 69.6 27.8 20.7 – – – – – – 10.1 34.0 139.4 20.0 6.7 69.7 20.4 20.1 55.2 6. refer to individual Gruvlok Coupling performance listing.5 51.3 – – – 27.2 17.0 6.7 20.5 55.D.2 24.5 51.7 6.6 27. Wall Thickness mm Maximum Working Pressure (bar) Fig.5 51. 76.5 51.0 3.7 – – – – – – – – – – – – – – – – – – – – – – – – – – – 34.4 457.6 61⁄2 O.8 2.7 – – – 12.6 17.7 12.5 34.1 – – – – – – 10.7 41.2 24.0 34.2 3.8 4.2 – – – – – – – – – 34.4 41.0 165.2 5.7 34.3 – – – 34. 7013 Flange Fig.6 27.7 – – – – – – 10.2 17.1 20.1 20.6 6.tEcHnIcAL dAtA on Roll Grooved ISO Size Steel Pipe Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.8 20.7 55.1 20.4 6.7 69.2 20.8 20.8 17.2 17.6 17.2 3.3 5.315 33.7 13.2 34.7 13.000 101.7 5.2 5.2 17.1 – – – – – – 13.3 13.1 80 76.2 Maximum line pressure.5 82. In.2 1.4 41.900 2.7 20.7 51.0 – – – 27.7 5.0 6.8 20.2 24.4 20.7 17.2 27.6 17.0 11⁄4 32 1 1.6 406.6 7.4 69 20.1 20.5 55.2 1.259 6.7 41.4 6.8 20.1 – – – 13.250 108.2 24.1 20.1 34.9 17.7 17.4 17.5 51.6 41.1 88.875 2.9 3.500 5 5 ⁄4 O.0 34.3 6.7 41.9 3.0 3.3 2.6 6.7 69.9 3.2 48.7 34.5 51.0 2.D.7 20.4 41.5 51.2 17.2 20.4 41.7 5. 8 10 12 14 16 18 10.0 34.7 – – – 13.D.4 42.3 – – – 27. * Rating based on larger pipe size.500 51⁄2 O.1 20.7 13.5 51.6 2. For coupling performance on standard wall steel pipe.0 20.7 69.5 51.8 20./mm Nom.2 13.7 51.0 3.2 5.4 41.2 3.9 17.1 20.0 609.5 55.6 34.0 – – – – – – 24.7 20.5 51.5 51.4 20.0 8.500 4.7 34.3 8.9 17.9 355.6 17.0 2.0 34.1 323.1 20.9 3.6 6.6 1.0 8.5 51.0 – – – 34.8 20.7 20.8 17. including surge.9 3.7 13.5 51.7 51.1 34.6 34.3 31⁄2 90 100 41⁄4 O.8 5.0 34.2 34.1 34.2 27.0 6.7 – – – 13.8 17.7 – – – – – – 24.2 8.6 7.7 20.4 20.6 2.236 5.7 – – – 13.6 2.1 20.5 17.7 13.8 20.2 20.750 12.1 20.6 34.7 20.5 51.4 82.0 34.2 – – – – – – – – – – – – – – – – – – – – – – – – 17. 7004 HPR Fig.6 1.2 17.7 20. www.7 41.7 12.7 6.3 13.2 – – – – – – 13.7 20.7 69.5 34.7 41.996 1 ⁄2 40 50 2 1 2 ⁄2 65 3 O.2 1.4 41.7 – – – 12.7 – – – 34.7 12.6 17.2 20.D.1 – – – – – – – – – – – – – – – – – – – – – 34.7 6.8 2.5 51.1 20.3 13. 7010* Reducing Fig. 134 0. 2) Failure to use Rollers specifically designed for Stainless Steel Pipe may significantly reduce pressure retention capabilities.875 73.180 0. GruVLoK couPLInG & FLAnGE WorKInG PrESSurE rAtInGS (PSI) on 304 And 316 StAInLESS StEEL roLL GrooVEd PIPE Nominal Pipe Size In.120 0.1 250 10 10.280 0.563 141.625 219.237 0.375 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 5S 10S 40 400 400 500 400 500 500 400 500 500 250 500 500 250 500 500 250 500 500 200 300 500 125 200 300 75 200 300 50 150 300 – – – – – – 400 500 750 400 500 750 400 500 750 325 500 750 325 500 750 325 500 750 250 400 750 200 300 500 125 200 500 75 200 400 50 100 400 75 125 400 – – – – – – 275 300 300 250 300 300 250 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 150 300 – – – – – – – – – – – – – – – 325 500 750 325 500 750 325 500 750 250 400 750 200 300 500 125 200 500 75 200 400 50 100 400 75 125 400 – – – – – – – – – 250 500 500 250 500 500 250 500 500 200 300 500 125 200 300 75 200 300 50 150 300 – – – – – – – – – – – – – – – 250 300 300 250 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 150 300 50 100 300 50 100 300 – – – – – – – – – 275 300 300 275 300 300 275 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 100 300 75 125 300 300 300 300 300 300 300 300 300 300 250 300 300 250 300 300 250 300 300 200 300 300 125 200 300 75 200 300 50 150 300 – – – – – – – – – – – – 400 500 750 325 500 750 325 500 750 325 500 750 250 400 750 200 300 500 125 200 500 75 200 400 50 100 400 75 125 400 – – – 275 300 300 275 300 300 275 300 300 200 300 300 200 300 300 200 300 300 – – – 125 250 275 75 150 275 – – – – – – Notes: 1) Pressure ratings based on ASTM A312 Type 304 stainless steel pipe or equivalent.500 88.11 .500 114. 7003 Hingelok Fig.065 0.134 0.109 0. 6) Pressure ratings on schedule 10 stainless steel pipe may be increased by using Anvil's 1007/3007 roll groovers with the schedule 10 roller set. the standard steel roll grooving set should be used. The Model 1007/3007 roll groovers require the use of the optional Schedule 10 roll set to groove Schedule 5S and 10S. 7013 Flange Fig.109 0.3 21⁄2 65 2.com GL-6.660 42.4 11⁄4 32 1.365 0.3 50 2 2.109 0.4 11⁄2 40 1.258 0.145 0. 7400 Rigidlite Fig. 7401 Rigidlok Fig. 7012 Flange Fig.140 0. 7000 Lightweight Fig.0 80 3 3.120 0. 7400SS Coupling 25 1 1.9 100 4 4.156 0.134 0. Contact Anvil for details.109 0.750 273.154 0.203 0. use the rating of the weakest end.tEcHnIcAL dAtA couplinG & flanGe workinG pressure ratinG on 304 and 316 Stainless Steel Roll Grooved Pipe The following are pressure ratings for Gruvlok Stainless Steel Piping Systems. 5) For pressure ratings for the reducing tees.3 125 5 5.083 0.625 168.D.anvilintl. For grooving Schedule 40S on the Model 1007/3007 roll groovers. 200 www. 4) * For pressure ratings on Figure 7010 Reducing Couplings use larger pipe size.148 0.109 0.065 0.900 48.3 200 8 8. For information regarding higher ratings contact Anvil.3 150 6 6.083 0. Using roll sets that were designed for roll grooving standard wall pipe may significantly reduce the pressure ratings that can be obtained.375 60.0 300 12 12.065 0.109 0.322 0. concentric reducers and eccentric reducers.216 0.750 323. 3) Pressure ratings on cut grooved pipe meet or exceed the schedule 40 pressure ratings listed above.133 0.120 0./mm Nominal Wall Thickness Inches Pipe Schedule Number – Coupling and Flanges Fig.9 0.165 0.315 33. The ratings for Schedule 10S pipe are based upon the use of roll-groover roll sets that have been specifically designed for use on Schedule 10 Stainless Steel pipe. In./DN(mm) Pipe O.065 0. 7010* Reducing PSI Fig.109 0. 7004 HPR Fig.083 0. 7001 Standard Fig. 8 4.1 19 5. and 3) permit required pipe system movement to relieve stress. The following factors should be considered when designing hangers and supports for a grooved-end pipe system.6 15 4.6 15 13 4 – – 18 5. table a *** Spacing by NFPA-13 Installation of Sprinkler Systems.1 12 3.9 45 13.1 37 11. As with any pipe system.2.5 19 4.9 15 5./DNmm * Steel Pipe Suggested Maximum Span Between Supports-Feet/Meters Water Service ** *** * Copper Tube Water Service *** ** Air Service ** Gas & Air Service ** 1 25 7 2.6 13 4 15 4.2 17 21 6.2 – – 21 6.8 21 6.7 15 4.3 139.1 17 15 4.2 20 6.4 20 6.6 15 14 4.7 15 4.9 4.D. (1996 Edition).6 30 9.4 15 4. Table 6-2. Table a. 11 3.3 14 18 5. 11⁄4-2 32-50 10 3.6 – 12 3.6 5.6 16 4.8 15 4.3 14 17 5.1 22 6.1 108.7 40 12.0 21⁄2-4 65-100 12 3.8 6. 921. couplings.6 10 3 14 4.7 42 12.7 – – – 12 3.7 11⁄2 40 7 2.6 15 6.1 27 8.1 19 5.0 51⁄2 O.3 15 4.7 – – – 9 2.D.3c.5 159.anvilintl.6 15 4.6 15 4.7 25 7.6 15 5.6 4.6 – 76.6 15 1 25 7 2. Do not use these values where critical span calculations are made or where there are concentrated loads between supports.7 – 12 3.6 9 2.9 Building Service Piping Code.1 36 10.1 21 6.6 42 12.6 1-2 25-50 1 1 1 2 1 1 2 2 1 2 2 2 3 2 2 3 2 2 4 2 2 4 3 3 5 4 3 6 4 3 24 600 32 9.D. StEEL PIPE FuLL LInEAr MoVEMEnt IS rEQ’d AVErAGE HAnGErS PEr PIPE LEnGtH EVEnLY SPAcEd Nominal Pipe Size Range In.6 24 7. PIPE HAnGEr SPAcInG: The following charts show the maximum span between pipe hangers for straight runs of standard weight steel pipe filled with water or other similar fluids.6 15 18-24 450-600 20 6.3 12 3.6 15 17 5. the hanger or support system must provide for 1) the weight of the pipe.7 10 3.3 20 4. Fig.9 17 6.0 5 125 51⁄4 O.3 7.5 15 4.2 20 6.7 12 3.0 15 4.3 22 4.3 33 9.6 15 4.6 39 11. 4.6 – – – – – – – – – – – – – – – – For straight runs without concentrated loads and where full linear movement IS required use the following tables.4 24 7. 4.6 6.6 15 15 4.6 15 9 2.4 19 15 4. the piping designer must consider certain unique characteristics of the grooved type coupling in addition to many universal pipe hanger and support design factors.6 15 4.6 20 6.7 4.4 12 3.1 8 200 5.3 15 4.1 15 4. DNmm 7 2.FLEXIBLE SYStEM.6 16 5.7 6 150 61⁄4 O.8 26 7.6 2 50 10 3 13 4 15 4.6 15 4.6 HAnGEr SPAcInG . ** Spacing by ANSI-B31.7 9 2.2 27 8.D.6 11⁄4 32 7 2.2 16 5.7 – – 17 5.1 15 4.6 12 300 23 7 26 7.8 15 4.7 4.6 15 6.3 23 6.1 Power Piping Code.6 15 4. HAnGEr SPAcInG .0 61⁄2 O.6 Pipe Length in Feet/Meters 15 4.1 165. 4.6 24 4.3 16 4.6 12 3.6 15 4. 5-24 125-600 www.6 15 5-8 125-200 14 4.8 15 4.1 10 3.3 25 4.6 29 8.2 HAnGEr SPAcInG LInEAr MoVEMEnt not rEQ’d Nominal Pipe Size Range In.D.4 18 15 4.3 – – 10-12 250-300 16 4.6 21 6.7 – – For straight runs without concentrated loads and where full linear movement is not required use the table on right.D.8 15 4.6 35 10.tEcHnIcAL dAtA Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.5 15 4.1 3 80 3.rIGId SYStEMS SuGGEStEd MAXIMuM SPAn BEtWEEn SuPPortS Nominal Size In.6 35 10.1 – Maximum Span Between Supports Feet/meters 4 100 41⁄4 O.6 15 5.4 11 15 4.9 14-16 350-400 18 5.2 18 450 27 8.7 12 3.2 19 5.3D. 2) reduce stresses at pipe joints. fluid and pipe system components.6 21⁄2-4 65-100 * Spacing by ANSI-B31.1 21 7.9 17 5.8 48 14.6 20 500 30 9.7 133.3 26 7. 921.0 18 4.7 14 350 23 7 26 7.7 9 2. 250 psi and Fig.7 24 7.12 201 .8 25 7.6 21⁄2 65 3 O. 14 4.8 24 4.4 20 7.1 15 4.1 35 10. 10 250 19 5.8 15 4.6 30 9.1./DNmm 31⁄2 90 13 4 18 5.com GL-7. 4.1.4 12 3. (1999 Edition).2 26 7.6 15 4. supports and anchors for a grooved-end pipe system.7 13 4 15 4.6 30 9.6 15 14 4. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe support When designing the hangers.6 15 4.7 40 12.0 21 4.9 15 4.7 4.6 16 400 27 8.1 11 3.6 15 4.1 9 2.0 12 3. etc. If it is a flexible system. With this in mind. clevis hanger. a high percentage are often related to the hanging or supporting method or application chosen. In this case 400 ft. The joint at a flexible grooved coupling can expand about 1⁄4" at each coupling whereas the joint at a rigid grooved coupling can grow about 3⁄32".com MAKE A MAtcH The type of grooved coupling used on a project is the next consideration to choosing the correct hanger or support method. Project logistics is another consideration regardless of system type. trapezes). and trapeze supports to more intricate rack designs using structural steel or a mechanical framing/strut system. can be hung or supported based on the maximum spacing requirements only. Once the system is pressurized. If this is not possible. System pressurization should also be reviewed when choosing the proper hanging or support method. 202 GL-7. In addition. the pipe ends can either be butted up tight to one another or a gap can exist. major equipment and schedule. If there is a long run of horizontal or vertical pipe with multiple joints the overall length of the system will grow depending upon which grooved coupling you have chosen. See accompanying illustrations for examples of typical assemblies. As one can see. eye nuts. 19 joints x .) and the lower attachment (pipe clamps. design and specification requirements.tEcHnIcAL dAtA pipe support Considerations for the Hanging or Supporting of Grooved Piping Systems Grooved piping products have an excellent maintenance track record out in the field.0076 in/ft. are the focus of the project team. such as labor. especially where a change of direction or a branch line connects. if you again take 400 ft. However. If this thermal growth exceeds the allowable deflection of a grooved joint. Hot And coLd Thermal expansion is another important consideration when choosing hangers or supports for a grooved system. This is significant growth especially if there is a change of direction at the end of the 400 ft. The proper maximum spacing allowables governed by project specifications. the applicable code and/or the hanger manufacturer’s recommendations all must also be reviewed. long there will be roughly 19 grooved joints (assuming 21 ft. The pipe is installed under ambient conditions assumed to be at 70°F so you have a 100°F variation in temperature. In other words the pipe has grown in length over 3 inches because of the thermal expansion. intermediate attachment (rod. this growth due to pressurization can have a significant impact on the hangers or supports used on a project. For example. lengths of pipe are used). Quite often hangers and supports are an afterthought on a project simply because the big-ticket items. if you have a grooved piping system that is 400 ft. At 70°F the pipe has a coefficient of thermal expansion of 0. x 0. a vital first step is to refer to the project and code requirements when choosing the proper hanging or supporting method.12 . wherever there is a change in direction of the piping system a hanger or support is usually required immediately following that change in direction and then the system is hung or supported accordingly. In nearly every hanger or support assembly there are three components that make up the assembly. As the couplings are installed. This is all due to the temperature variation from ambient conditions when the pipe is installed to operating conditions. If you multiply the number of joints by the growth of each joint you can determine the overall growth of the system due to pressurization. Whenever there is a “perceived” problem with installed grooved product.75" of overall growth. couplings. Components can also be bundled and tagged by system or area of the project so they can be easily assembled and located on-site. This is especially important on hot systems versus chilled systems since the amount of thermal expansion will be greater on hot systems as opposed to the thermal contraction that will occur on chilled systems. To save costly field labor hours. Although supported very similarly to welded piping systems. These components are an upper attachment (beam or structural attachment). One way to avoid this growth is to install the grooved joints at full gap so that pressurization has no impact at testing or start up. = 3. PrESSurE PoInt rEVIEW rEQuIrEMEntS And LoGIStIcS A variety of hangers and supports are typically used on grooved piping systems.04 in. To determine the total thermal expansion of the pipe from ambient temperature to operating temperature you multiply the length of pipe by the coefficient of thermal expansion. U-bolts. of grooved piping. All three components should arrive on the project site together and early.0938" = 1. www.25" = 4.78" of overall growth. For example. Rigid couplings. then problems could occur. consideration might be given to having the hangers or supports pre-assembled by the manufacturer or fabricated in the contractor’s shop. then periodic air pressurization as the system is installed will expand the grooved joints to full gap and the hangers or supports can be adjusted accordingly. let us assume the system is heating hot water that will operate at 170°F. pipe run or there are branch lines coming off the main run. Flexible couplings used on horizontal runs of pipe need to be supported at every coupling and usually require intermediate supports to satisfy the maximum spacing allowable requirements.0076 in/ft. A rigid system would be 19 joints x . those areas or joints where the pipe ends are butted up tight and held by a grooved coupling can “pop” or grow to the maximum gap depending on the coupling chosen. on the other hand.0 in/ft but at 170°F the pipe has a coefficient of thermal expansion of 0. ranging from a simple band hanger. All of these are acceptable hanging or supporting methods but they are dependent on the project’s type. a few considerations should be given to assure the proper selection and application of hangers and supports used on a grooved piping system such as Anvil’s Gruvlok® brand.anvilintl. hangers and supports are one of the first components needed on a project since you cannot hang pipe without them. one can best determine the proper selection and application of hangers and supports for a grooved piping system.04". Vertical pipe thermally expands the same amount as horizontal pipe and this has to be taken into consideration relating to supports. The use of static hangers. Whether it is horizontal or vertical grooved pipe. On hot systems. run of pipe was 4. conSIdEr SoME rEStrAInt Although grooved systems in seismic zones perform extremely well. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe support upper upper intermediate intermediate lower lower upper intermediate lower lower upper intermediate Clevis Hanger Assembly Double Bolt Pipe Clamp Assembly Trapeze Assembly Spring Riser Hanger Assembly Thermal growth cannot be stopped. www. Seismic restraints in the lateral direction should have little impact on expansion except where the system has a change in direction. the clamps will grow with the pipe off the penetration or supporting structure and no longer provide support. Seismic restraints in the longitudinal direction of a long pipe run may restrict the growth of the pipe inducing stresses into the grooved couplings. This will. If the growth is downward.78" for a rigid joint system and the thermal expansion was 3. the expansion of the long pipe run may be restricted and this could induce excessive stress into the grooved joints. growth of the piping system due to pressurization and thermal expansion must be considered. If the pipe is a vertical riser then consideration must be given to the use of spring hangers to allow the pipe to grow vertically up or down depending upon how the pipe is anchored while still supporting the pipe. If you have growth due to pressurization and/or thermal expansion consideration should be given on how to restrain the system while still allowing growth to occur. to allow the hot systems to thermally expand on the trapeze.anvilintl. pressurization. Again.75" for a flexible joint system and 1. such as clevis hangers. In either case the clamps are no longer supporting the pipe as intended and this may induce excessive stress on the grooved joints.com GL-6. When using trapeze hangers for multiple systems it is important to have “like” systems on the trapeze. regardless of the horizontal or vertical orientation of the pipe. Hot systems should be hung or supported independently of cold or ambient systems or a means should be provided. this is a significant amount of growth relating to hangers and supports and the resulting stresses induced on grooved joints. such as pipe rolls or pipe slides. If the vertical pipe is supported by friction/riser clamps only and the pipe expands vertically upward. the thermal expansion of the hot system can cause the trapeze to possibly twist and fail or excessive stress could be induced on the grooved joints on all of the systems on the trapeze. By reviewing the couplings to be used on a project. Adding these combinations together would result in a total pipe growth of 7. in turn. that is. the friction clamps resting on the penetration or supporting structure can either fail or the pipe may overcome the friction force and push it’s way through the clamp as the pipe thermally expands downward. pressurization expansion on the 400 ft. It can only be controlled by the use of anchors and expansion joints or expansion loops. help ensure that grooved piping systems will continue to enjoy a solid reputation in the areas of maintenance and downtime. both must be taken into account and added together to determine the overall growth of the system and the effect on the hangers or supports that are used.11 203 . It is also important to hang or support the pipe with rolls or slides and use guides to control the thermal expansion of the pipe into an expansion joint or expansion loop. systems that are operating near the same temperature. consideration should be given to how a grooved system is seismically restrained.79" for a flexible system or 4.tEcHnIcAL dAtA Considerations for the Hanging or Supporting of Grooved Piping Systems Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.82" for a rigid system. In the previous examples. thermal expansion and seismic restraints. should not be considered on pipe that is thermally expanding. If the seismic restraints are placed laterally after a change in direction at the end of a long run of pipe. expansion joints or expansion loops. If you combine hot systems with cold systems on a trapeze. com GL-6. SUFFICIENT LENGTH TO OFFSET PRESSURE THRUST The pipe designer must assure himself that the system has the capability of deflecting sufficiently to absorb this movement without introducing additional stresses into the pipe system. Random flexible coupling joint installation will produce installed coupling conditions ranging from pipe ends full butted to fully separated to the maximum available gap. System With No Pressure L2 L1 System Pressurized EXAMPLE 2 This illustrates the effect of pump oscillation on a piping system. or a base support at Point “D2” to support the vertical column. L1 no additional anchoring is required. EXAMPLE 3 To restrain this system provide a pressure thrust anchor at “R1” to resist the pressure thrust acting through the tee “D1” at the cap “C”. should accommodate the deflection without transmitting bending stresses through the pipe system. The Gruvlok coupling does not restrain adjacent pipe sections from separation due to pressure forces until the coupling key sections engage the groove walls. temperature increases would produce further expansion of the pipe system thus increasing the deflection. EXAMPLE 2 In the system shown here. to direct the pipe movement L2 so as to prevent introducing bending stresses into the system. In the deflected condition shown. The couplings in the horizontal run above the riser. Thus. and L3 are of adequate length to handle expected pipe movements. Examples of the effect of pressure thrust are shown in the following illustrations. the pipe will move and deflect at the elbow joint due to pressure thrust.tEcHnIcAL dAtA couplinG flexibility: The grooved coupling’s capability to allow angular and rotational movement within the coupling joint must be considered when deciding hanger and support locations. and D1 intermediate anchors located as required. When pressurized the pipe ends in the coupling joints will separate to the maximum amount permitted by the coupling design. The coupling key sections will make contact with the groove walls and restrain the pipe from further separation. Thermal movement of the pipe R1 R2 C system should also be considered.anvilintl. D2 L3 204 www. Spring hangers and supports providing for movement in more than one plane are often used to allow the pipe system to move without introducing additional stress into the pipe system. EXAMPLE 1 The coupling joints have been installed butted or partially open. PrESSurE tHruStS: Gruvlok couplings react to the application of system pressure and restrain the pipe ends from separation due to the pressure force. the coupling joint may not be in the self-restraining configuration prior to the application of system pressure. A spring hanger should be used to support the pipe section and also respond to the induced vibrations. The movement at each coupling joint will add with all other joints and produce ∆L. However. Provide a hanger at Point “R2”. The designer must account for the movement to be encountered when the system is pressurized and the joints are fully separated. The sag due to the flexibility of the Gruvlok joint could be eliminated with the proper positioning of hangers on both pipe segments “L1” and “L2”. EXAMPLE 1 This example demonstrates the need for each pipe length in a grooved system to be supported.11 . L2. Anchor and guide positions must be defined to direct the pipe joint movement that it is not detrimental to the pipe system. If the offsets L1. only after system pressurization will the self-restraining function of the coupling be in effect. welded.anvilintl. couplings and fluid. Provide pipe guides on every other pipe length. Note that no intermediate anchors are required. the pipe ends will be fully separated. weight of pipe and the fluid column. This method creates a predetermined gap at each pipe joint which can be utilized in pipe systems where thermal movement is anticipated and in systems with rigid (threaded. Note that when installing risers. Anchor at “B” with an anchor capable of withstanding full pressure thrust at the top of the riser plus weight of pipe column. due to pressure thrust. the pipe ends are butted together within the coupling joint. flanged) branch connections where shear forces due to pressure thrust could damage the rigid connections. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories couplinG flexibility (cont. When the system is pressurized the pipe stack will “grow” due to pressure thrust which causes maximum separation of pipe ends within the couplings. the pipe movement due to pressure thrust will be strained and there will be no shear forces acting at the branch connections. the spacer removed and the coupling is then installed. as a minimum. The following examples illustrate methods of installing commonly encountered riser designs. D A L1 VERTICAL COLUMN B HORIZONTAL RUN C VERTICAL COLUMN L2 M L E LAtErAL rEStrAInt System with no pressure partially deflected System pressurized fully deflected EXAMPLE 5 A grooved coupling joint installed in a partially deflected condition between anchor locations will deflect to its fully deflected condition when pressurized. The upper pipe length is anchored. Place intermediate anchors “C” as shown. Anchors at “B” and “C” if offsets at L1 and L2 are insufficiently long to handle expected pipe movements. rISErS WItHout BrAncH connEctIonS Install the riser with the pipe ends butted. Use spring hanger at “D” and “E” to allow movement of vertical piping. Hangers and supports must be selected with consideration of the hanger’s capability to provide lateral restraint. In the most common method. B rISEr dESIGn: Risers assembled with Gruvlok Flexible couplings are generally installed in either of two ways. Locate an anchor at the base of the riser (A) to support the total weight of the pipe. the gasket is first placed onto the lower pipe and rolled back away from the pipe end prior to positioning the upper pipe.com C C C A GL-6. When this system is pressurized. when. rISErS WItH BrAncH connEctIonS Install the riser with the predetermined gap method. Light duty hangers. may deflect against the application of lateral forces and result in “snaking” conditions of the pipe system. between the pipe ends when an additional length of pipe is added to the riser stack. The maximum amount of A stack growth can be predetermined (see Linear Movement). Also place intermediate clamps at every other pipe length as a minimum. while acceptable in many installations. www. An alternative method or riser installation is to place a metal spacer of a predetermined thickness.) EXAMPLE 4 Anchor at “A” to support weight of vertical water column.11 205 .tEcHnIcAL dAtA Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Anchoring of the riser may be done prior to pressurization with the pipe ends butted or while pressurized. In this example the pipe length “L” at the top of the riser must be long enough to permit sufficient deflection (see Angular Movement) to accommodate the total movement “M” from both pressure thrust and thermal gradients. between anchors “A” and “B”. Anchor the pipe at or near the base with a pressure thrust anchor “A” capable of supporting the full pressure thrust. to prevent possible deflection of the pipe line at the coupling joints as the riser expands due to pressure thrust or thermal growth. 7075 7074 SYMBOL COMPONENT ELBOW 90° ADAPTER FIG. NO. NO. 7055 SYMBOL MPT MPT 45° ADAPTER EXPANSION JOINT GRUVLOK FLANGE 7056 7092 7012 7013 FPT GF MATING FLG 4 2 11 2 LATERAL 45° STRAIGHT 7069 7047 2 FPT 4 11 2 FPT 6 REDUCING 7070 6 4 REDUCER COUPLINGS STRAIGHT 6 7072 4 7000 7001 7003 7004 7011 7400 7401 7010 7068 CONCENTRIC ECCENTRIC TEE 6 7073 4 REDUCING 6 4 STRAIGHT 7060 CROSS REDUCING 7061 6 4 6 TURNED-DOWN ELBOW 90° 7050 TRUE-WYE 45° 7051 GRUVLOK BUTTERFLY BALL VALVE CHECK VALVE TURNED-UP – – 7071 TURNED-DOWN TURNED-UP – – SERIES 7700 7500 7800 All fittings are shown with couplings attached at the grooved-ends.com GL-6.11 .anvilintl.tEcHnIcAL dAtA draftinG symbols for Gruvlok® pipinG systems COMPONENT BULL-PLUG CAP CLAMP-T GROOVED OUTLET FEMALE THREADED OUTLET CLAMP-T-CROSS GROOVED OUTLETS FEMALE THREADED OUTLETS 7048 7046 7044 7045 FIG. 206 www. all pipe must be prepared to receive a Gruvlok coupling or other Gruvlok pipe system components. or cutting a hole in the pipe wall.D.D. metal is displaced while a groove is formed into the outer surface of the pipe wall.12 207 . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe-preparation: To create a Gruvlok pipe joint. Gruvlok pipe grooving and hole cutting machines are available in a wide variety of designs to meet specific or general requirements. Branch outlet connections require a properly sized and correctly located hole to be cut into the pipe. The groove configuration has slightly rounded edges resulting in a less flexible joint than a cut groove joint. Roll Grooving Roll Groove Cut Groove The I. and deflection capabilities of the Gruvlok coupling. (on an average) less than 2%. Cut grooving produces a groove in the pipe wall by removing metal from the pipe O.tEcHnIcAL dAtA Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. This reduces available pipe joint movement by 50% over cut grooved coupling joints. Available Movement Roll Groove vs. grooving is not required.375" wall steel pipe and sizes to 24" O. cut or roll grooving. concentric with the pipe O. The square cut edge of the groove allows for the full expansion. Thread Volume of Metal Removed Cut Groove vs. pipe may be grooved by either of two methods. Cut Grooving Depth of Cut Groove vs.D. Threaded roll GroovinG: Roll grooving does not remove metal.anvilintl. Sock-it connections require cleaning of the pipe end.D.D. Roll grooving is commonly used on a wide range of pipe thicknesses up to 0. Required pipe preparations may include: grooving or cleaning the pipe ends. contraction. The groove removes less than one half of the pipe wall and does not cut as deeply into the pipe wall as do standard pipe threads. Gruvlok plain-end pipe couplings require that the pipe be free of burrs and other sharp projections which could damage the gasket. Cut Groove www. cut GroovinG: Cut grooving is intended for use with standard and heavier wall pipe. Gruvlok hole cutting tools properly center holes for correct assembly of Gruvlok branch outlet components.. Gruvlok roll grooving machines produce a groove to proper dimensional tolerances. Instead. For grooved-end joints. even on out-of-round pipe.com GL-7. “dimple" formed from roll grooving reduces the I. 875 2. 7005 Roughneck Couplings must be free of any notches. 1 32. Bevel not to exceed 1⁄16".1 sock-it® For Sock-It Fittings.76mm) for all sizes.7 41⁄2 114. 208 www.357 2.. The outside pipe surfaces within 5/8" of the hole must be clean and smooth.375 2.5 42. etc. left on the pipe from cutting must be removed.5 25⁄8 66.4 33. 3⁄4. Soft pipe when roll cut may be swaged inward.3 48.030" (0.904 73.9 15. Pipe ends must be marked a distance of 1" from the pipe end for Sizes 2"-4" and 11/ 4" from the pipe end for Sizes 5"-8" as a guide for centering of the gasket on the pipe ends. 20.352 2. which might effect gasket sealing integrity. sharp projections.6 48. the pipe ends must be square cut as measured from a true square line.tEcHnIcAL dAtA pipe-preparation: branch outlet pipe: clamp-t® Clamp-T installations require the cutting of a hole through the pipe wall.6 41./mm Surface Prep.D. The surface around the entire circumference of the pipe within the “A” dimension in the charts must be free from dirt.630 1. In. Perm.5 mm) for 8" sizes. Beveled pipe.D. After cutting. weld bead. scale.1 15⁄8 41.900 2.882 1. In.1 51⁄2 139./mm Max.385 2.8 21⁄8 54. rust. it may damage the gasket as the pipe is inserted into the Sock-It Fitting.D. 0.9 35⁄8 92.060" (1.5 61⁄2 165.7 41.030" (0.1 59.4mm) back from the pipe end to remove all pipe coating.1 mm) for 4" through 6". In. or projections which might effect the proper assembly of the Clamp-T. The sharp O.7 47.D. Dull wheel cutter produces a raised ridge at the pipe O./mm Square cut pipe with O.D.875 73.3 21⁄2 65 23⁄4 69.D.846 2./mm After the hole has been cut into the pipe 5⁄8" wall.D. pipe ends must be completely cleaned a minimum of 1" (25. 40 11⁄2 38./mm Min. burrs. O.910 2.670 1. “A” In. rouGhneck® Plain-End pipe for use with Fig.com GL-6.D.295 1./mm Max.6 1. ⁄2. Any sharp edges. etc. Size DN/mm Schedule 10 & 40 Nom O.3 72. The hole must be properly sized and located on the centerline of the pipe to assure reliable performance of the Clamp-T gaskets.8 60./mm In. AccEPtABLE PIPE End conFIGurAtIon Remove Burr & Sharp Edge 1⁄32" to 1⁄16" 30 or 45 3⁄16" Max.3 45⁄8 117. for at least 11/2" (38 mm) back from the pipe end to provide a smooth sealing surface for the gasket. giving an oversize diameter.9 27⁄8 73. and 0.0 43⁄4 120.7 3 80 31⁄2 88. edge left by different methods of cutting pipe must be removed.8 47.642 1. they may damage the gasket as the pipe is inserted into the Sock-It Fitting. will tend to cut gasket during assembly. Pipe ends (plain or beveled end) must be square cut as measured from a true square line with the maximum allowable tolerance as follows: 0. Any scale.7 mm) for 2" through 3". The nominal outside diameter of pipe should not vary more than ±1% for sizes up to 21/2".2 33. PIPE toLErAncES notE: When Allied XL pipe is used it is necessary only to remove sharp edges and burrs at the end of the pipe.045 (1.325 1.660 1. burr & sharp edge removed is preferred configuration.0 60.anvilintl.7 4 100 41⁄2 114. A Branch Size DN/mm 1 cLAMP-t InStALLAtIon Hole Dimensions Hole Saw Size In. O. weld beads.11 . If this sharp edge is not removed. 11⁄2 2 50 2 50. XL Min. +1/16”-1/32" for sizes 6" and larger. Swaged portion not to exceed 3⁄16" 11⁄4 11⁄2 40 50 65 32 25 1 1.6 unAccEPtABLE 2 21⁄2 Excessive chamfer on I.3 42. O. No additional cleaning is required. Diameter In.837 72.285 1.0 4 101. score marks. etc.3 31⁄2 88.9 59.6 21⁄2 63.4 32.4 1. +1%-1/32” for sizes 3"-5". projections or indentation which might effect the gasket sealing on the pipe must be removed. bumps. The maximum allowable tolerance is 0. 25 11⁄4.9 32. Abrasive wheels & saws leave edge burrs especially pronounced on one side. any burrs and sharp or rough edges must be removed from the hole. If these are not removed.315 1. 109 2.031 0.6 4.996 +0.9 +0.48 5.88 8.0 12.083 2.34 0.0 14.40 -0.7 2.24 0.031 15.76 0. COLUMN 3 .8 6.350 133.91 15.2 +0.42 +0. 133.094 2.031 15.79 -0.15 -0. COLUMN 2 .16 0.600 91.2 14 O.69 0.563 141.74 0.8 5.625 219.51 -0.76 0.156 4.469 11.44 -0.46 -0.88 0.51 -0.6 14.79 15.109 142.031 -0.1 0.11 0.74 0.000 25.76 0.11 209 .188 4.6 24.13 0.38 0.8 0.015 -0. +0.350 108.35 30.14 1.030 -0.000 406.334 -0.900 48.60 0. Failure to do so may result in damage to the roll grooving machine and unacceptable roll grooves may be produced.91 10.anvilintl.938 23.063 -0. 1.109 2.625 15.74 0.083 2.042 -0.6 +0.3 +0.750 ▼ 44.9 18 O.77 0.480 63.165 4.0 4 100 51⁄4 O.8 0.D.625 15. (See column 6). and ID prior to roll grooving. see the Technical Data/Install Instructions section on Anvil’s web site .40 0.0 +0.93 0.76 0.781 350. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories roll Groove specifications A B T GruVLoK StAndArd roLL GrooVE SPEcIFIcAtIon For StEEL & otHEr IPS or ISo SIZE PIPE -1-2O.79 1.51 -0.76 0.344 8.281 7.031 0.56 -0.3 20 O./mm -6“D” (Ref.2 16.109 135.156 4.D.70 23.063 +1.030 -0.344 84.625 15.016 -0. COLUMN 8 .010 51.109 2.14 1.79 -0.76 0.D.109 161.88 0./mm C In.60 0.74 160.88 0.018 -0.08 5.9 +0.056 +1.015 -0.4 16.625 15.40 0.60 -0.109 2./mm -8Max.11 0.980 75.344 8.3 +0.26 3. 762.35 0.48 -0.79 -0.000 355. 4.430 36.4 31⁄2 90 41⁄4 O.4 12 300 12.1 78.100 104.88 8.750 19.109 2.7 30 O. ▼ “A” tolerance +0. Groove must conform to the groove diameter “C” listed in column 5.96 -0. Seams must be ground flush with the pipe O.469 11.020 1.083 2.344 8.93 0.160 512.084 -0.350 159.030 -0.031 -0.51 -0.74 0.7 5 125 61⁄4 O.56 2. Wall Thick In.083 2.7 5.88 6./mm OD Nominal Pipe Size Tolerance +In.0 21⁄2 65 3 O.0 11⁄2 40 1.063 1.250 +0.3 5.60 -0.060" (+0.2 18.190 30.D.083 2. Failure to do so may result in damage to the roll grooving machine and unacceptable roll grooves may be produced.60 0.092 2.625 0.770 45.025 -0.32 +0.076 2.020 0.5 10 250 10.79 1.531 318.Roll Grooving Approval Specifications.000 609.660 143.625 15.031 -0.9 5.39 0.781 400.200 761.60 -0.078 1.0 +0.052 -0.38 0.88 0.53 6.625 8./mm -5“C” Tol.109 110.085 2. 457.781 451.031 -0.79 -0.1 +0.063 1.500 12.7 3.344 154.031 -0.D.063 -0.063 +1.063 +1.D.7 2.79 -0.000 -In.23 -0.37 0./mm -In.020 -0.720 69.74 0. Actual In.000 25.7 1.4 +0.14 +0. For ISO size pipe.500 +1. For IPS pipe.8 167.7 1.344 135.084 -0.029 +0.83 0.D.625 8.1 2 50 2.625 0.920 328. COLUMN 7 .0 5.165 4.76 In.60 -0.com www.469 11.315 33.48 0.45 0.77 0.281 7.03 6.anvilintl.2 +0.063 +1.750 19.03" for 1" thru 31⁄2".085 2.D.1 4.30 -0.109 2.063 +1.54 mm) 11⁄4 32 1.250 57. ISO outside diameter.134 3.25 (371⁄2°) is acceptable.063 +1.063 +1.98 0.79 0.031 -0.38 0.1 0.74 2.600 165.88 0.74 72.024 +0.79 0.98 2.160 461.7 3.1 0.86 -0.9 8 200 8.029 +0.79 0.www. and 1.334 110. 108.73 4.000 101.61 0.100 408. COLUMN 4 .tEcHnIcAL dAtA Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.D.344 8.2 18. and minimum O.083 2.625 8.730 170.91 19.79 -0.1 NOTE: VdS .019 -0.000 457.000 762.344 8.625 15.77 / -1.172 4.500 749. measured at 90° must not exceed total O.344 129.76 -0.019 +0.56 -0.600 116.79 0. seams.600 139. Gasket seat width (Dimension A) is to be measured from the pipe end to the vertical flank in the groove wall.60 -0.09 2./mm Flare -3- -4“C” Actual In.045" for 4" thru 6".344 2.com GL-6.8 0.1 0.16 2.29 -0. Allow.078 1.625 15.79 0.395 137.084 2.088 2.018 0.018 -0.50mm for sizes 200mm and above.88 0.88 0.0 4.0 51⁄2 O.344 103.031 -0.88 0.0 30.60 -0.259 +1.Groove depth: for reference only.3 6.469 11.100 76.D.4 10.441 214.05 0.8 0.D.D./mm “A” “B” ±0.625 15.030 -0. 2. and ID prior to roll grooving.74 -0./mm In.74 +0.750 19. chips.88 0.64 -0.035 +0.76 ±0.1 16 O.94 -0.D.Maximum allowable pipe end flare diameter.031 -0.74 0.660 42. In.1 +0. tolerance listed (reference column 2).775 45. Beveled-End Pipe in conformance with ANSI B16.36 -0.200 614.344 3.055 -0.13 5.8 8.022 -0.625 168.79 1.031 -0.D.75mm for sizes 25mm80mm.030 0.625 15.40 +0.Groove width (Dimension B) is to be measured between vertical flank of the groove size walls.040 +1.46 1. and 0.625 15. COLUMN 5 .8 20.045 +1.083 2.469 11.938 23. 0.6 +0.022 2.375 60.065 1.5 4.469 11.Nominal IPS Pipe size.89 -0.875 73.845 -0.656 600.065 1. however square cut is preferred.02 +0.77 0.76 +0.063 1.1 3 80 76.38 0.060" for sizes 8" and above measured from a true square line.91 12.11 0.3 +1.065 1.8 0.60 -0.83 0.344 8.750 273.2 5.920 277.3 6.015 -0.109 2.0 6.834 97. 355.334 -0.11 0.14 1.100 358.60 0.281 7.0 61⁄2 O.030/ ±0. Weld Seams must be ground flush with the pipe O.344 8.27 -0.74 0.083 0.022 -0.60 +0.05 0.91 8.063 +1.38 4.028 +0.60 0.74 0.79 -0.05 0.1 24 O.562 268.024 -0.076 0.535 38.000 508.79 -0.500 114. 609.1 6 150 165.027 -0.71 -0.88 0.015 -0. rust or scale which may interfere with proper sealing of the gasket. Flare Dia.46 -0.625 15.218 5.083 4.030 -0.07 +0. Only) In.51 -0.083 2.236 +1.031 -0.74 -0. 159.020 2.D.3 COLUMN 1 .60 -0.781 502.91 17.88 0.60 +0.031 -0.031 -0.61 -0.38 0.250 6.D.109 2.031 15.88 0.031 15.063 1.The groove must be of uniform depth around the entire pipe circumference.250 6.79 15.000 25.84 -0.030" / -0.60 -0.40 0.88 0.88 29.1 0. Nominal ISO Pipe size.029 -0.093 2.91 13. 406. the maximum allowable tolerance from square cut ends is 0.500 +1.99 -0.74 0.5 24.455 163. the maximum allowable tolerance from square cut ends is 0.15mm for sizes 100mm-150mm./mm -7“T” Min.04 -0.084 -0.41 0.88 0.56 -0.500 88.469 11. Out of roundness: Difference between maximum O.625 8.6 6.4 +0. 508./DN(mm) D 1 25 1.015 -0.77 0.063 +1.D.750 323. COLUMN 6 .030 -0.D.1 6.030 -0.800 223.77 0.0 20.Minimum allowable wall thickness which may be roll grooved.0 2.64 0. Measured at the most extreme pipe end diameter of the gasket seat area.065 1.79 1.IPS outside diameter.022 2.031 -0.063 1.Gasket seat must be free from scores. measured from a true square line.09 -0. 139.1 3.74 0.030/ ±0.020 -0. 60 0.60 +0.88 6.D.063 +1./mm In.076 0.8 0.8 0.020 -0.4 +0.70 19.D.0 4 100 51⁄4 O. “C” Seat “A” Width “B” Groove Allow.2 18.70 17.88 0./mm In.11 .9 +0.145 3.48 -0.022 -0.344 84.078 2.334 -0.720 69.625 15.203 133.9 0.312 7.79 0. seams.0 5.79 0.625 9. tolerance listed. ±0.40 0.7 5 125 61⁄4 O.9 21⁄2 65 3 O.79 0.750▼ 44.88 0.3 6.625 15.79 1.500 +1.60 -0.51 -0.42 +0.0 2.084 2.500 114. 733.69 -0.48 0.53 0.27 -0. For IPS pipe.08 5.89 -0.71 -0.4 12 300 12.031 15.79 1.32 +0. measured from a true square line.13 5.030 -0.031 -0.000 101.219 5. 787.83 0.022 -0.092 2.625 15.D.88 0.219 165.38 0.375 9.0 4.64 -0.781 350.79 -0. not to be used with End Guard gaskets.9 18 O.6 0.083 2.109 2.38 0.088 5.D.000 787.375 135.D.030" / -0.76 -0.0 30.312 7.084 -0. 2.79 15.54 mm) 139.2 0.203 5.000 25.92 0. and 0.172 4.250 31.1 0.031 -0.500 12.2 0.56 -0. 1.40 0.334 -0.88 30.031 -0.76 ±0.045 +1. the maximum allowable tolerance from square cut ends is 0.23 -0.53 0.53 0.73 4.79 -0.60 -0.3 0. Out of roundness: Difference between maximum O. Actual In.000 762.1 +0.437 11.10 8.563 14. ▼ “A” tolerance +0. and 1.083 0.334 110./DN(mm) A -7- B T -2O.062 1.0 +0.031 -0.8 0.0 0.625 9.30 23.2 0.042 -0.781 502.9 +0.5 28 I.46 1.625 15. chips.031 0.020 0.74 -0.083 5.030 -0.4 0.625 9.029 +0.88 210 www.020 -0.000 25.312 7.063 -0. 406.56 -0.79 -0.38 0.1 6 150 165.031 -0.60 -0.76 +0.60 -0.063 +1.36 0.1 0.88 0./mm OD C 1 25 1.188 4.6 0.6 +0.109 2.6 +0.76 0.781 400.140 3.030 0.085 2.375 9.000 508. COLUMN 6 Groove depth: for reference only.3 +1.030 Depth “D” Wall Tol.46 -0.084 -0. 457.09 -0.500 12. “T” In.000 (Ref.6 0.6 8 200 8.0 20.40 -0.2 0. Nominal ISO Pipe size.40 0.031 -0.625 0.88 7.063 +1.86 -0.tEcHnIcAL dAtA cut Groove specifications GruVLoK StAndArd cut GrooVE SPEcIFIcAtIon For StEEL & otHEr IPS or ISo SIZE PIPE -1Nominal IPS Pipe Size In.500 +1. 159.8 0.74 +0.79 1.D.70 15.031 -0.9 0.D.625 15.625 15.8 31⁄2 90 41⁄4 O.45 0.1 16 O.53 0.76 0.625 15.190 30.88 29.250 6.563 14.375 9.02 +0.88 0.031 15.76 0.3 +0. 508. 355.031 -0.D.60 -0.076 5.com GL-6.1 +0. rust or scale which may interfere with proper coupling assembly.030 -0.25 (371⁄2°) is acceptable.031 15.6 0.281 7.41 0.30 28.063 +1.53 0.53 0.060" (+0.D.2 0.027 -0.76 0.249 159.70 10.750 19.500 12.022 2.14 +0.05 0. Only) Thick.312 7./mm -In.109 2.96 -0.000 25.76 0.083 2.875 73.88 0.056 +1.1 0.236 +1.09 2. measured at 90° must not exceed total O.016 -0.030 -0.312 7.375 103.375 60.562 268.92 72.D.40 0./mm Groove Diameter Gasket Groove Actual Min. COLUMN 5 The groove must be of uniform depth around the entire pipe circumference.029 -0.07 +0.6 11⁄2 40 1.019 +0.063 +1.055 -0.500 12.4 0.4 +0.88 0.6 4.020 1.312 7.030 -0.38 0.203 5.74 -0.03 6.052 -0.750 273.79 15.79 1.88 0.028 +0.312 7.030 -0. (See column 6).015 -0.D.88 0.093 2.1 14 O.88 0.031 -0.30 0.79 -0.441 214.4 16.75 0.025 -0. 4.70 13.2 5.09 -0.030 ±0.312 7.99 -0.375 154.250 +0.9 20 O.063 1.88 0.35 0.92 1.455 163.6 0.031 -0.60 -0.625 15.625 15.625 15.063 +1.000 406.563 141.76 0./mm -3- -4- -5- -6- Tolerance +In.83 0.92 0. the maximum allowable tolerance from square cut ends is 0. COLUMN 3 & 4 Gasket seat must be free from scores. 0.94 -0.8 0.51 -0.61 -0.938 23.40 +0.000 457.75mm for sizes 25mm80mm.1 0.79 -0.063 +1.375 129.018 -0. however square cut is preferred.44 -0.625 219.000 25.3 5.50mm for sizes 200mm and above.0 51⁄2 O.60 +0.203 108.062 1.51 -0.D.031 15.375 3.53 160. and minimum O.38 4.70 12.56 2.53 6.D.531 318.04 -0.88 0.4 D 11⁄4 32 1.031 -0.29 -0.500 12.172 4.312 2.51 -0.656 600.79 1.48 5.535 38.085 6.000 609. 609.062 1.D.D.238 6.7 5.7 30 O.084 -0.109 2.203 5.1 10 250 10.045" for 4" thru 6”.03" for 1" thru 31⁄2".029 +0.188 4.030 -0.88 9.76 +0.845 -0.031 -0.015 -0.030 -0.8 0.9 24 O.063 +1.625 15.05 0.015 -0.79 -0.625 9.996 +0.060" for sizes 8" and above measured from a true square line./mm In.031 0.2 +0.15 -0. ISO outside diameter.3 0.79 -0.79 0.938 23.79 0.15mm for sizes 100mm.60 -0. 762.0 0.4 28.133 3.250 6.38 0.625 15.188 76.024 -0.46 -0.6 24.660 42.094 2.500 12.015 -0.92 0.0 61⁄2 O.019 -0. 108.2 0.8 0.279 7.3 +0.030 -0.26 3.625 0. Groove must conform to the groove diameter “C” listed in column 5.60 -0.437 11.56 -0.312 7.062 1.031 -0.500 88.625 168.1 3.750 19.500 749.109 2.531 724.154 3.312 7.031 -0.1 0.015 -0./mm -In.92 1.4 +0.315 33.018 -0.60 -0.60 -0.76 0. For ISO size pipe.4 +0.51 -0.031 -0.1 6.84 -0.8 0. Actual ±0.92 1.2 0.0 4.64 0.022 2.69 0.6 14.781 451.035 +0.834 97. COLUMN 7 Minimum allowable wall thickness which may be cut grooved.77 / -1.063 -0.92 2. 133.024 +0.063 +1.040 +1.750 323.018 0.750 19.594 777.000 355.875 733.259 +1.900 48.203 COLUMN 1 Nominal IPS Pipe size.05 0.88 0.79 1.1 30 I.250 57.anvilintl.0 6. 139.375 9.D./mm In.61 0.063 +1.88 0.625 15.1 3 80 76.4 31.020 2.395 137.2 0.60 -0.775 45.76 0. COLUMN 2 IPS outside diameter.063 +1.2 +0.078 2.500 12.79 -0.4 0.150mm.7 2 50 2.53 0. Beveled-End Pipe in conformance with ANSI B16.D.187 4.D. 188 0.625 10./mm Groove Depth Min.3 88.018 -0.60 +1.27 214./mm Tol.46 -0.61 +14.14 18.13 -0./mm Gasket Seat “A” Actual In.15 -0.27 214.26 +18.750 323.390 0.030 -0.13 -0./mm -In.024 +0.79 -0.0 3.056 +0.38 0.005 -0.51 -0.13 -0.300 0.79 -0.60 +1.com GL-6.018 -0.300 0.344 110.3 +0.0 60.89 +0.0 2.76 -0.078 0.1 6.35 +0.455 8.395 6.719 10. In.(+0.51 -0.9 273.500 5.38 0.025 -0.1 2.020 +0.51 0.031 -0.562 0.094 0.010) -In.0 2.38 2.25 -0.625 8.74 -0.+/In.250 0.8 2. “D” “T” In./mm Tolerance +In.750 12.024 -0.40 *Refer to additional notes on previous page.14 +0.045 +0.8 2.610 0.4 2.1 219.14 15.51 0.083 0.078 0.010 -0.75 6.020 -0.031 -0.083 0.018 -0.26 +18.005 -0.79 -0.219 0.09 84./mm Groove Width “B” Actual In.375 2.14 18.46 -0.79 -0.0 60.2 2.005 -0.79 -0./mm Gasket Seat “A” Actual In.056 +0.020 -0. In.305 0.563 6.64 -0.035 +0.27 14.91 7.714 0.13 -0.015 +0.029 -0.3 141. (Ref.109 2.562 0.083 0.53 +14.25 0.13 2.062 0.14 +0.031 -0.250 0.8 2./mm In.531 318.254 -0.60 +1.49 +18./mm Groove Diameter “C” Actual In.62 7.29 268.03 163.6 0.56 -0.719 4.020 +0.500 4.455 8.134 0.29 268.16 10.714 18.279 7.875 3.010) -In.024 -0.11 211 Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.400 10.51 0.37 15.015 +0.27 +0.063 +0.375 2.4 2.005 -0.005 -0.250 0.015 +0.60 +1.094 0.62 6.010 +0.48 6.720 3.203 0.38 0.025 -0.27 14.74 +0./mm -In.562 0.91 9.94 57.063 +1. Gruvlok EG fittings are grooved in accordance with these dimensions C D End GuArd (EG) cut GrooVE SPEcIFIcAtIonS* Nominal IPS Pipe Size In.500 4.79 -0.029 +0.79 -0.018 -0.8 4.51 -0./mm Groove Width “B” Actual In.75 7.9 73.46 -0.400 0.714 0.084 0.063 +0.0 1.64 -0.719 0.031 -0.49 +15.010 +0.020 +0.020 0.045 +0.38 0.015 +0.51 -0.024 +0.7 0.79 -0.562 12.38 0.3 114.62 7.46 -0.010 +0.305 0.400 0.75 7.078 0.08 137.109 2.563 6.53 +15.3 114.605 0.010 -0.875 3.031 -0.065 0. Only) Wall Thick.25 -0.022 -0.96 69.084 0.91 9.005 -0.42 +1.8 4.03 163.020 -0.020 -0.09 84.255 0.1 168.572 -0.38 0.062 0./mm Groove Depth Min.26 0.0 3 4 5 6 8 4. “D” “T” In.063 +0./mm Tol./mm Tol.300 0.750 323.9 73./mm In.441 10 12 0.48 -0.3 2.61 -0.031 -0.51 0.69 -0.156 4.610 0.030 -0.61 -0./mm Groove Diameter “C” Actual In.203 0.020 -0.083 0.720 3.51 0.063 +0.063 +1.74 -0.2 5.625 8.750 12.085 0.015 -0.083 0.063 +0.1 2.572 3 4 5 6 8 0.79 -0.51 0./mm Tol.031 -0.334 5.79 -0.1 1.020 +0.3 +0.334 5./DN(mm) Pipe Outside Diameter Actual In.51 -0.610 0.154 0.51 0.49 +15.51 -0.8 2.395 6.60 +1.390 9.572 0.3 2.344 110.255 0.(+0.25 0.022 -0.020 -0.109 0.085 0.255 0.1 2.238 0.96 69.031 -0./mm 21⁄2 65 80 100 125 150 200 250 300 50 2 2.51 -0.13 -0.027 -0.027 -0.605 0.56 -0.020 -0.0 1.390 0.015 -0.4 6.79 -0.1 5.08 137.078 0.51 -0.441 10 12 10.38 0.020 -0.092 0.305 0.029 -0.022 -0./mm Tol.1 219.94 57. A B T C D End GuArd (EG) roLL GrooVE SPEcIFIcAtIonS* Nominal IPS Pipe Size In.015 +0./DN(mm) Pipe Outside Diameter Actual In.6 5.015 +0.1 168.3 88.035 +0.69 -0.010 -0.anvilintl.51 -0.1 2.3 141.020 -0.16 7. Allow (Ref. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories cut Groove end Guard® specification OD .38 0.020 -0.6 0. Flare roll Groove end Guard® specification End Guard (EG) roll groove is designed for lightwall pipe to be joined by HPR 7004 EG couplings.015 +0.020 +0.35 6./mm Tolerance +In.250 2.029 +0./mm 21⁄2 65 80 100 125 150 200 250 300 50 2 2.015 0.031 -0.8 2.188 0.531 318.031 -0.2 4.56 -0.+/In.25 0. www.109 0.89 +0.79 -0.1 2.031 -0.42 +1.562 12.250 2.031 -0. Only) Wall Thick.031 -0.51 -0.063 +0.38 0.38 0.250 0.2 2.031 -0.74 +0.020 -0.605 0.60 +1.4 2.022 -0.37 15.40 *Refer to additional notes on previous page.76 -0.15 -0.48 6. Allow.9 273.61 0.60 +1.625 10./mm Tol.53 +14.109 0.37 14.1 2.35 6.60 +1.79 -0.015 +0.56 -0.092 0.tEcHnIcAL dAtA A B T OD End Guard (EG) cut groove is designed for standard or heavier wall thickness pipe to be joined by HPR 7004 EG couplings.79 -0.500 5.16 10. 05 0.2 5. roll marks. +/– 0./mm Nominal Groove Depth “D” In.053 1.6 7.300 7.5 0.5 0.03 in.020 -0.020 -0.05 0.610 15.05 0.54 -0.004 0.002 0./mm -3Gasket Seat “A” +/– 0.999 126.020 -0. +0./mm -5Groove Diameter “C” Actual In. COLUMN 7 DWV (Drain.anvilintl.5 0.14 -0.030"/0.610 15.002 0.048 1./mm -4Groove Width “B” +0.14mm for sizes 4-8" COLUMN 3 Gasket seat must be free from scores.05 0.000 – In.97 -0.125 130.7 2. COLUMN 6 Groove depth is for reference only.050 1.16 -0.610 15.019 102. Allowable tolerance from square cut ends is 0.4 0.5 0.05 0.002 0.0 0.8 0.4 0.610 15.002 0.300 7.6 2.51 0.76mm In.125 104./mm -7Min.220 56.84 -0. In.020 -0.51 0.999 152./mm – In.com GL-6.03/–0.6 2. Waste and Vent Piping) per ASTM B306.6 0.125 155.51 0.5 0. grease and dirt which may interfere with gasket sealing.610 15. -2Tubing Outside Diameter Actual In.300 7.3 DWV DWV DWV DWV DWV 3.51 0.058 1.51 0.6 5. 212 www.5 0.37 -0.220 107.2 0. COLUMN 8 Maximum flare diameter is the OD at the most extreme tubing diameter. COLUMN 4 Groove width is to be free from chips.1 3.8 4.4 2.11 . See column 6.002 0. COLUMN 5 Groove diameter must be of uniform depth for the entire circumference of the tubing.00 in.029 51.002 0.002 0.3 4.8 COLUMN 1 Nominal tubing size ASTM B88 COLUMN 2 Outside diameter of copper tubing per ASTM B88.00mm In.002 0.020 -0.065 1./mm -8Max. which may interfere with proper coupling assembly. etc.1 8.08 -0. the groove diameter must conform to column 5.625 66.020 -0.002 0.125 206.2 0.10 0.220 158.05 0.tEcHnIcAL dAtA Gruvlok cts copper system Roll Groove Specifications A B T Flare OD C D GruVLoK ctS coPPEr SYStEM – roLL GrooVE SPEcIFIcAtIonS -1Nominal Size In. dirt.002 0.300 7.6 2.300 7.05 0.0 8./mm -6Tolerance +0.063 1.3 5.6 4.76/–0.002 0.002 0.6 4.002 0.05 0.51 0. Wall “T” In.125 79.05 0.5 0.05 0.220 208.6 6.610 15.720 69.053 1.025 76. indentations. Flare Diam.6 3.7 0.610 15.05 0.05 0. 0.3 0.300 7.020 -0.220 81.6 6./mm Tolerance + In.125 54.51 0.083 2.300 7./mm 2 21⁄2 3 4 5 6 8 2.05 0.050 1.220 132.045"/1.959 202.525 64.76mm for sizes 2"-3". 4 514./mm Coupling Figure 7000 7000 7000 7000 7000 7000 7000 7001 7001 Dimensions X In.4 1 10 12 6. 7240 – order form When requesting a quotation or placing an order.5 596./mm Compressed Length L In.1 273.6 117.5 495.625 8.9 3.750 201⁄4 201⁄4 6./mm O.D.1 323.9 101. 7000 4'' FIG.8 793.0 88.8 31. 7000 4'' FIG.5 482.8 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 11⁄4 21⁄2 65 80 100 125 150 200 250 300 2.5 327.1 171.2 1 3 4 5 6 8 45⁄8 57⁄8 7 8 63⁄4 81⁄8 95⁄8 11 3./mm Expanded Length L In.8 31. 7240 order form NIPPLE X COUPLING END ADAPTER GRUVLOK GRUVLOK GRUVLOK GRUVLOK Y L PErForMAncE dAtA Nominal Size In.2 263.8 31.6 482.3 628.7 311⁄4 311⁄4 311⁄4 183⁄4 3.4 fiG.750 12.4 1 5.anvilintl./mm Y In.4 1 19 6.3 51⁄2 53⁄4 762 762 762 444.2 1 171⁄2 19 6. 7000 4'' FIG.4 1 103⁄8 127⁄8 15 131⁄4 171⁄2 191⁄2 221⁄2 231⁄2 231⁄2 233⁄4 243⁄4 243⁄4 6./mm 50 2 2.8 31.3 219.375 60.8 31. 7000 4'' FIG.562 6.2 1 ⁄8 ⁄8 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 31. In. 40 steel): ___________________________________________________________ 5) Finish on pipe (standard is black): _________________________________________________________________________________ 6) Finish on couplings (standard is painted): ___________________________________________________________________________ 7) Gasket material (standard is Grade E EPDM): ________________________________________________________________________ 8) Connecting pipe ends if different than standard roll or cut groove: _____________________________________________________ 9) Are there any silicone restrictions for the application? ________ Yes ________ No www.4 244.6 571.875 3.9 596.3 73.3 168./mm Coupling Movement Capability In.8 203.4 1 6.4 603.0 31⁄2 4 125 146.2 177.8 476.11 213 .3 141.8 31.5 279.4 336.8 31.8 31.500 114.0 381./mm 1 GRUVLOK 4'' FIG.7 628.5 149. please complete the following form and fax a copy to 717-684-2131 to the attention of Customer Service: 1) Size and material of pipe to which the Expansion Joint will be connected ______________________________________________ 2) Factory to preset the Expansion Joint to: _________ Full Expansion _________ Full Contraction ________ Intermediate 3) Total overall movement while in service: ____________________________________________________________________ inches 4) Pipe material for Expansion Joint (standard is sch.5 206.6 444.8 793.9 88.625 10.9 30 30 30 793.3 514. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories fiG. 7000 Number of Couplings 10 10 10 5 5 5 5 5 5 Total Movement Capability In.com GL-6.tEcHnIcAL dAtA Expansion Joints Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.500 4. C.Standard Specification for Ferritic Malleable Iron Castings.Standard Specification for Pipe. ASTM International (ASTM) A36 . R. ASTM International (ASTM) A240 .12 . 1. C. Sheet and Strip.Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products. Application. Zinc-Coated. S. Section 15400 .com GL-7.Selection and Application. Carbon. Carbon.Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate. Carbon Steel. M-Grades. H. B.4 MPa) working pressure with 3 to 1 or greater safety working pressure with the exception of plain-end end fittings. P. E. American Society of Mechanical Engineers (ASME) B31. O. American Society of Mechanical Engineers (ASME) B31. fittings. Manufacturers Standardization Society of The Valve and Fittings Industry (MSS) SP-77 Guidelines for Pipe Support Contractual Relationships. K. Hot-Rolled. Manufacturers Standardization Society of The Valve and Fittings Industry (MSS) SP-90 Guidelines on Terminology for Pipe Hangers and Supports. for General Industrial Use.Pipes Valves and Fittings for HVAC Heating and Cooling. System Design Requirements: 1. Chromium-Molybdenum. V.4 SYSTEM DESCRIPTION A.1 . U.9 . T. E.Pipes. ASTM International (ASTM) A47 . couplings. Product: Gruvlok as manufactured by Anvil International.Standard Specification for Gray Iron Castings. fittings and valves for piped building systems. ASTM International (ASTM) A1011 . L. F. Section 15060 .Standard Specification for Pressure Vessel Plates. Manufacturers Standardization Society of The Valve and Fittings Industry (MSS) SP-89 Pipe Hangers and Supports . J. 1. ASTM International (ASTM) A53 . ASTM International (ASTM) A536 . Manufacturers Standardization Society of The Valve and Fittings Industry (MSS) SP-58 Pipe Hangers and Supports .2 RELATED SECTIONS A. Fire Protection UL/ULC listed and FM approved products shall conform to NFPA working pressures. 1. ASTM International (ASTM) A153 . ASTM International (ASTM) A668 .Piping Specialties. Alloy Steel. M. W. Valves and Fittings for Fire Protection Systems. 214 www.3 REFERENCES A. Section 15300 . Section 15600 . B. and Strip for Pressure Vessels and for General Applications.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15050 part 1 General 1.Standard Specification for Ductile Iron Castings. Valves and Fittings for Plumbing Systems. Manufacturers Standardization Society of The Valve and Fittings Industry (MSS) SP-69 Pipe Hangers and Supports . valves and grooved components shall be used as the piping method. ASTM International (ASTM) A387 . Mechanical commercial and industrial piping products shall have a minimum 300-psi (2. 2.Pipes.Materials. Structural. Sheet.1 SECTION INCLUDES Basic Mechanical Methods and Materials A. High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability.Specification for Zinc Coating (Hot Dip) on Iron & Steel Hardware. Piping. Selection.Power Piping (SI Edition). which shall have a minimum of 175-psi (1.Standard Specification for Steel. N.Fabrication and Installation Practices. Black and Hot-Dipped.Building Services Piping. Steel. ASTM International (ASTM) B633 .Standard Specification for Carbon Structural Steel. American Society of Mechanical Engineers (ASME) B31. ASTM International (ASTM) A575 . ASTM International (ASTM) A123 . I. ASTM International (ASTM) A515 . G.anvilintl.Chemical Plant and Petroleum Refinery Piping. Design and Manufacture. Section 15500 . Welded and Seamless. ASTM International (ASTM) A48 .Standard Specification for Steel Forgings. D.2MPa) working pressure.Standard Specification for Electrodeposited Coatings of Zinc on Iron and Steel.Standard Specification for Pressure Vessel Plates. 1. Manufacturers Standardization Society of The Valve and Fittings Industry (MSS) SP-127 Bracing for Piping Systems Seismic-Wind-Dynamic Design. Q. Grooved Mechanical Products: Couplings.Hangers and Supports. Grooved products shall meet National and Local Piping and/or Building Codes.3 . B. D.Standard Specification for Steel Bars. for Intermediate-and Higher-Temperature Service. Carbon and Alloy. Merchant Quality. C. and establish condition and completeness of substrate.) 1. in accordance with requirements of local authorities having jurisdiction. Portsmouth.9 WARRANTY A. Verification Samples: For each finish product specified. Grooving shall conform to Gruvlok published grooving specifications. Manufacturer's Warranty: Submit. Do not install products under environmental conditions outside manufacturer's absolute limits.com B. Substitutions: Not permitted. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Certifications: 1. C. 1. Web: www. other rights. B. Certificates shall be furnished only as required by specific codes. Requests for substitutions will be considered in accordance with provisions of Section 01600. Acceptable Manufacturer: Anvil International.8 PROJECT CONDITIONS A.ANSI B-31. 1. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15050 (cont. and patterns. Preparation instructions and recommendations. Include methods for maintaining installed products. Owner may have under Contract Documents. 2. Steel Piping: Black Steel and/or galvanized pipe conforming to ASTM A-53. Warranty: Warranty documents. and ventilation) within limits recommended by manufacturer for optimum results. B.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Basic Mechanical Methods and Materials 3. Tel: 603-422-8000. Selection Samples: For each finish product specified.9 standards for horizontal and vertical pipe support design criteria. upon request. B.1 . Product Data: Manufacturer's data sheets on each product to be used. which is located at: 110 Corporate Dr. Maintain environmental conditions (temperature. and materials used with solvent-based materials. Closeout Submittals: 1. D. Steel Piping: Black Steel and/or galvanized pipe conforming to ASTM A-135 or A-795. Incorporate in construction pipe hangers and supports to manufacturer's recommendations utilizing manufacturer's regular production components. representing actual product. 1. humidity. E. minimum size 6 inches (150 mm) square. and not a limitation of.12 215 . 2. manufacturer's standard warranty document executed by authorized company official. and precautions against cleaning materials and methods detrimental to finishes and performance. Conduct pre-installation meeting to verify project requirements. Store and dispose of solvent-based materials. Manufacturer Qualifications: 1.7 DELIVERY. Installation methods. 1.6 QUALITY ASSURANCE A. Submit under provisions of Section 01300.2 MANUFACTURERS A.anvilintl. Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section. Email:
[email protected] MANUFACTURERS A. two complete sets of color chips representing manufacturer's full range of available colors and patterns. Fax: 603-422-8033. Manufacturer's warranty is in addition to. part 2 products 2. coordinate with other trades. 2. AND HANDLING A.com. Grooved piping installation shall meet ANSI B-31. Store products in manufacturer's unopened packaging until ready for installation. www. F. STORAGE. Grade A or B. Review manufacturer's installation instructions and manufacturer's warranty requirements. color.5 SUBMITTALS A. B. parts and assemblies. NH 03801. two samples. including: 1. Manufacturing facilities shall be registered to ISO 9001:2008 and assessed to ISO 9001:2008 standard. A copy of the current certificate shall be available upon request. Grooving shall conform to Gruvlok published grooving specifications. Suite 10 .anvilintl. Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. for Owner's acceptance.com GL-7. MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15050 (cont. 8. 6. and outlet couplings shall be used for vibration. Standard coupling gaskets for building services shall be Grade "EP" EPDM conforming to ASTM D-2000 with operating temperature range from -40 degrees F to +250 degrees F (-40 degrees C to 121 degrees C). 2.0 MPa). Grooving shall conform to Gruvlok published grooving specifications. Grade A or B. forged steel.72 MPa).com GL-7. Other fittings are schedule 80 or light wall as scheduled. c. Coatings shall be (Orange) Alkyd-enamel rust inhibiting lead free paint. 6. Use other gasket materials as recommended for petroleum service and other applications. Standard schedule 40 pipe shall be roll or cut grooved. 1. 1. C. Grade "EP" EPDM gasket 3.anvilintl. Steel Piping: Black Steel and/or galvanized pipe conforming to ASTM A-53. 4. Gruvlok Style 7001 (Flexible) couplings shall be used for vibration attenuation and noise suppression at equipment locations. Sizes 1 inches to 30 inches (25 mm to 762 mm) diameter: a. b. Gruvlok Xtreme Lubricant E. Couplings and Grooved Flange Adapters shall conform to ASTM A-536 Ductile Grade 65-45-12 or to ASTM A-47 Malleable Grade 32510. Cast ductile conforms to ASTM A-536 or cast malleable iron conforms to ASTM A-47. Forged steel fittings shall conform to ASTM A-234 or A-106 Grade B. D. b.40 degree F and +230 degree F (-40 degree C and 110 degree C). Steel Piping: Black Steel and/or galvanized pipe conforming to ASTM A-53.0 MPa). a. flexible. 2. 3. D. Grooved Flange Adapters: Flange adapters to transition from flange to groove with no nipple shall be Gruvlok Fig 7012 or Figure 7013: 1. 2. F.12 . 7. 216 www. Grooved Couplings for Steel Pipe Systems and other Approved Piping: 1. Gasket Lubricant: Coupling gaskets except where noted shall be lubricated with approved lubricant. 2. Systems Subject to Thermal Cycling: Gruvlok Xtreme Lubricant. 9. Bolts and nuts shall be zinc electroplated. Fittings shall conform to Cast Ductile ASTM A-536 or Cast Malleable ASTM A-47. L. and DWV shall be used in conjunction with the Gruvlok Copper roll grooved method. and/or segmental welded steel fittings. Clamp type couplings shall be used for branch outlets. Gruvlok style 6400 rigid coupling and style 6084 flange adapter. Segmental welded conforms to ASTM A-53. 5. 1.3 FITTINGS A. Copper Systems: Gruvlok Xtreme Lubricant. 3. 4. 3. 2. Forged steel conforms to ASTM A-234. Figure 7013: 2 inches through 12 inches (51 mm through 305 mm) available for ANSI class 250 or 300 lb (113 kg or 136 kg) bolt pattern and is rated at 750 psig (5 MPa). 4. Grooved Fittings for Steel Piping Systems . 3. 2. noise suppression and seismic tremor. Combination rigid. Sizes 2 inches through 20 inches (51 mm through 508 mm) are rated at 300 psig (2. Hot Dip Galvanized fittings conform to ASTM A-153. 5. Hex nuts shall conform to ASTM A-563 Grade A. B.) Basic Mechanical Methods and Materials C. 2. 7. Grooving shall conform to Gruvlok published grooving specifications. Figure 7012: Conforms to ANSI class 125 or 150 lb (57 or 68 kg). Coating shall be hot dipped galvanized fittings shall conform to ASTM A-153. Segmental welded fittings shall conform to ASTM A-53. Schedule 10 pipe and below shall be roll grooved. E. Grooved Couplings for Copper Tube Systems: Coupling working pressure not to exceed 300 psig (2. 5. Size 24 inches (610 mm) is rated at 250 psig (1. Sizes 1 inch to 30 inches (25 mm to 762 mm): Gruvlok Style 7401 Rigidlok couplings shall be used including style 7012 flange adapters. 3. Grade A or B. Fittings shall be coated with an Alkyd-enamel non-toxic paint. Coupling Track Head Bolts shall conform to ASTM A-183 Grade 2. Flanges in Figures 7012 and 7013 are designed with internal anti-rotation tines and are designated as a rigid connection. Grade "E" EPDM gaskets shall be used for water service applications with temperature ranges between . Material: 1. 1. M. 4. malleable. Copper Tubing: Copper tube to comply with ASTM B-88. Types K. Figures 7012 and 7013 flange adapters require sealing rings when used with certain flanged products. Environments below -20 degrees F (-28 degrees C). Flexible or other style couplings designed for axial motion or other movements shall be supported in strict accordance with factory recommendations. Zinc electroplated fittings conform to ASTM B-633. Standard Fittings shall be schedule 40 or standard wall.Shall be Gruvlok cast ductile. and above 150 degrees F (66 degrees C) and systems subject to continuous cycle temperature changes: Gruvlok Xtreme Lubricant. oval neck track head bolts conforming to ASTM A-183 Grade 2. Intended for working pressures 300 to 750 psig (2. Branch outlets from 1/2 inch to 3 inches (13 mm to 76 mm) diameter.2 KPa to 2. Designated as a bolted-on positive pipe engagement branch outlet. Gruvlok Balancing Valves . Run Sizes 2 inches to 8 inches (51 mm to 203 mm). Stem Guide: Ductile iron. Track Head Bolts and Hex Nuts: Couplings shall be furnished with heat-treated.Model FTV-S. Outlet Couplings: Shall be Gruvlok Figure 7042 with grooved or threaded outlets. Plain End Couplings and Fittings: Gruvlok Roughneck coupling Style 7005 and plain-end fittings to match. 2.Model GBV-T (Threaded). 5. Working pressure to 500 psi (3. Seat-Guide: Bronze. Fittings are cast or forged steel. C. Copper fittings shall be 99. Gruvlok Balancing Valves . E.Model GBV-S (Soldered). Size: As indicated on drawings. Housing: Steel tube to comply with ASTM A513. non-asbestos packing.9 percent lead free. 5. Body: Ductile iron. Bolts shall meet minimum tensile strength of 110. Size range is 2 inches to 16 inches (51 mm to 406 mm) diameter. Plumbing Code approved and UL/ULC listed. and Clamp-T Cross Figure 7047. 6. Grooved Copper Fittings: Gruvlok Wrot Copper fittings per ASTM B-75 and ANSI B-16. 8. 1. 3. 2. Liner: Polypropylene to ASTM D4140. Operating Temperature -40 degrees F to +230 degrees F (-40 degrees C to 100 degrees C).22. Gruvlok Balancing Valves . Gruvlok Tri-Service Valves . Size: As indicated on drawings. Size range is 1 inch to 2-1/2 inches (25 mm to 64 mm) diameter: Plain End "Sock-it" Method: Gruvlok Sock-it fitting series 7100 through 7107. Branch Outlets: Shall be Gruvlok Clamp-T Styles 7045 and 7046.com GL-7. Materials conform to ASTM A-536 and A-47. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15050 (cont. 4. Seat: Bronze. comply with ASTM B584.Model GBV-A (Grooved-End Angle). 2.) 2. www. 1.2 KPa) with bolts fully torque to factory recommend torque requirements on plain-end or beveled standard wall steel pipe and Gruvlok Plain-End fittings. Size: As indicated on drawings. Size range is 3/4 inch to 6 inches (19 mm to 152 mm) diameter.5 KPa).000 psi (758 KPa). I. Gruvlok Balancing Valves . H. 3. 4. Spring: 302 stainless steel. 3. comply with ASTM B21. 7. D. 9.300 psi (1. 2. Run sizes 1-1/2 inches to 6 inches (38 mm to 152 mm). L. 2.Model FTV-A. 4. Stem: Bronze. Hex nuts shall be carbon steel conforming to ASTM A-563 Grade A. Disc: Cast iron. J. comply with ASTM A126. with positive shutoff and micrometer type handwheel adjustment. 2.12 217 . 3.anvilintl.0 KPa) UL/ULC listed and FM approved. Working pressures from 175 . 2. comply with ASTM A395 or ASTM A536. 10. Bolts and nuts shall be zinc electroplated. F. K. Gruvlok Tri-Service Valves . Provide tamperproof memory stop. 2.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Basic Mechanical Methods and Materials G. 1. comply with ASTM B584. 1. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.0 KPa to 5.Model GBV-G (Grooved-End Straight). comply with ASTM A536. Disc Guide: Cast iron.4 GROOVED CONNECTION FLOW CONTROL VALVES A. Flanged Gland: Cast iron. Couplings and Wrought Copper Fittings shall be NSF. 1. Branch outlets from 1/2 inch to 2 inches (13 mm to 51 mm) diameter. Working pressure shall be 500-psig minimum. M. 3. 300 psig (2 MPa). Disc: Bronze. comply with ASTM A126. alloy C12200. 1. comply with ASTM A126. 11. Material conforms to ASTM A-126 Class A Cast Iron. 7048 and 7049 with grooved or threaded outlets. Seat: Ultra-high strength engineered resin. Packing: Graphited. Shall inhibit the formation of a galvanic cell between dissimilar metals. B. Gaskets for Industrial and Other Piping Systems: Systems with different media products shall be provided with industrial grade gaskets as scheduled. 1. 1. Body and Yoke: Ductile iron. comply with ASTM A395 or ASTM A536. Wrought Copper fittings size 2 inches to 8 inches (51 mm to 203 mm) diameter shall be schedule 10 or standard wall 304 or 316 stainless steel. Di-Electric Insulated Pipe Connections: Di-LOK Figure 7091 grooved by grooved insulating nipple. Type and Description: Y-style globe valve with 4 full-turn adjustment. Fittings match coupling working pressure. Material: Cast bronze. pressure differential ports on both sides of the valve. Grade: Grade T . Install in accordance with manufacturer's instructions. GBV-A (Grooved-End Angle): 1. Size: As indicated on drawings. GBV-T (Threaded). D. Install no fittings within 2 pipe diameters downstream of valve. Provide templates to ensure accurate location of anchor bolts. Plain-end coupling and fitting installation shall comply with specific torque and installation requirements. Trim: Brass C-37700. G. 3. Grade 65-42-12.4 VALVE INSTALLATION A.) 5. 218 www. 2. 6.Models FTV-S. undulations or deformities. Gasket lubricant shall be used to assure proper coupling gasket seating. GBV-T.Nitrile. 4. 3. 3. Companion or mating flanges shall have a flat hard surface and shall be free from gouges.5 EQUIPMENT ANCHOR BOLTS AND TEMPLATES A. suitable for system pressure and temperatures encountered. Disc: Ductile iron. Field grooving or pipe cutting of galvanized pipe may require repair of possible damaged galvanized pipe ends. Valve body has been designed to handle the weight of the pump on vertical in-line installations. General: Grooved piping installation shall meet ANSI B-31. B. Tines in the housing key section engage to provide a rigid pipe connection. Two coats of spray-on "liquidgalvanize" are recommended. comply with ASTM A536. Install rigid couplings that utilize a tongue-and-groove housing for precise coupling alignment and engagement.1 EXAMINATION A.3 INSTALLATION A. Do not mount valve directly to pump to avoid causing undesirable noise in the system.ANSI B-31. Consult current manufacturer's product installation data. 6. Grade 65-42-12. 2. and conformance with gasket service usage. Provide pipe supports under valve and strainer bodies.Model GBV-G (Grooved-End Straight). If substrate preparation is the responsibility of another installer. Support piping by hangers. 6. Upper and Lower Shaft: Type 416 stainless steel.com GL-7. To ensure accuracy of measurement of GBV-S. part 3 execution 3. B. FTV-A: 1. locate valves at least 5 pipe diameters downstream from any fitting and at least 10 pipe diameters downstream from a pump. GBV-G and GBV-A valves. 3. comply with ASTM A536. Balancing Valves . E.2 PREPARATION A. Leave sufficient clearance around valve for valve removal or repair. F. Install valve in the direction of flow arrows on valve body. Clean surfaces thoroughly prior to installation. Body Coating: Nylon. 5. 5. Mount valve to flanged equipment using Gruvlok Flange Adapter or industry standard grooved coupling. C.EPDM. Globe Valves .12 . Basic Mechanical Methods and Materials G. Pipe ends shall be clean and free from indentations.anvilintl. Grade: Grade E . 7.1 . Tri-Service Valves . Mount valve to a spool piece on the discharge side of the pump. Gruvlok Butterfly Valves . Body: Ductile iron. Do not begin installation until substrates have been properly prepared. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. Use flange gasket sealing rings if mating surfaces are not uniform. notify Architect of unsatisfactory preparation before proceeding. 2.Model GBV-S (Soldered). rust or damage. H. Spool piece required is based on a minimum recommended space of 12 inches (305 mm) for pump sizes 2 inches by 2 inches (51 mm by 51 mm) to 6 inches by 6 inches (152 mm by 152 mm) and 24 inches (610 mm) for pump sizes 8 inches by 8 inches (203 mm by 203 mm) to 12 inches by 12 inches (305 x 305 mm).MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15050 (cont. O-ring: Nitrile. B.Series 7700: 1. burrs. B. 3. 2. 4. The valve body is not designed to support the piping weight.9 Codes for Pressure Piping. 5. Refer to Section 15060 . Section 15500 . Materials shall be installed in accordance with current NFPA Standards.Basic Materials and Methods and Section 15500 . D. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 9. making sure non-asbestos gasket is in place. Pipe. 3. Selection. of type as indicated.Firestopping.1 SECTION INCLUDES Pipes. Scope of work: 1. ASTM International (ASTM) A536 . 4. local Rating Bureau and/or local Fire Marshall requirements.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Basic Mechanical Methods and Materials 3. 7. E.Hangers and Supports. 6. Incorporate in construction pipe hangers and supports to manufacturer's recommendations utilizing manufacturer's regular production components. 8. maintenance and use of protective signaling devices. Install valves in horizontal or vertical piping as indicated.4 SYSTEM DESCRIPTION A. drain ports and handwheel. D. 5. Do not install metering ports below the pipe (pointing down). 4.anvilintl.Grooved products for steel and copper fire protection systems shall be used.2 SECTION INCLUDES A.Installation of sprinkler systems.12 219 . All areas as indicated on the drawings are to be protected by an automatic suppression system. C. B. System components to be UL listed/FM approved and labeled. Provide easy access to probe metering ports (PMPs). www. and Fittings .Access Doors and Panels. 1.Piping Specialties. B.Installation. Section 15060 .Hangers and Supports. Refer to Section 15050 . Dry-pipe.3 REFERENCES A. C. System components to be to be rated for minimum operating pressure of 175 psig.Basic Mechanical Methods and Materials. solder valve body in line using 95/5 solder. E.) END OF SECTION section 15300 part 1 General 1. Metering ports and body/drain plugs may be interchanged for improved accessibility.Standard Specification for Ductile Iron Castings. Valves and Fittings for Fire Protection Systems A. parts and assemblies. Wet pipe. NFPA 13 . and shall provide the necessary engineering drawings and calculations to obtain acceptance of all authorities having jurisdiction. Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) SP-127 Bracing for Piping Systems Seismic-Wind-Dynamic Design. as this will allow system sediment to accumulate in the ports. B. Install valve-bonnet assembly into body. Section 15050 . Products shall be UL/ULC listed and FM approved. NFPA 72 . Valves. B.com GL-7.Piping Specialties. Dry-standpipe. Section 07840 . 1. 1. C. Install valves with flow in the direction of the arrow on the valve body. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15050 (cont. Contractor shall be responsible for designing the distribution systems and sizing of the systems by hydraulic calculation. For solder applications. 2. D. Application. Wet standpipe. Section 08310 . upon request. Contractor shall obtain all necessary permits and licenses pertaining to this Division (expense borne by the Contractor) and comply with Municipal and State Codes. or as otherwise specified. and establish condition and completeness of substrate. 1. Submit under provisions of Section 01300. Installation methods. 2. including: 1. and ventilation) within limits recommended by manufacturer for optimum results. Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section.9 PROJECT CONDITIONS A. 1. 1. B. Certificates shall be furnished only as required by specific codes. products. hangers. Certifications: 1. shafts. Shop Drawings: 1. fittings. Valves and Fittings for Fire Protection Systems B. 2. and accessories in a single submittal. 1. "Piping" includes all pipe. and materials used with solvent-based materials. C. D. during the period of one year. Store and dispose of solvent-based materials. coordinate with other trades. Ordinances and Regulations. "Or equivalent" means to possess the same performance qualities and characteristics and fulfill the utilitarian function without any decrease in quality. Pipes. STORAGE. G. Conduct pre-installation meeting to verify project requirements. E. in accordance with requirements of local authorities having jurisdiction. and post all bonds incident thereto. "Fire Protection Work" is all of the work Indicated or required by the Contract Documents.12 .5 SUBMITTALS A. F.anvilintl.7 DEFINITION A.6 QUALITY ASSURANCE A. and the requirements of the National Fire protection Association. and that if. Closeout Submittals: 1. C. In default thereof. 220 www. 1. Warranty documents. AND HANDLING A. and pay all fees and sales taxes as required. in writing. and precautions against cleaning materials and methods detrimental to finishes and performance. embedded in construction. stating effective date of Warranty. Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. Review manufacturer's installation instructions and manufacturer's warranty requirements. D.) 1. furred spaces. remedy such defects within a reasonable time as specified in notice from the Owner's Representative. material or performance appear. and other supports and accessories related to such piping. to the Owner's Representative. from the date of substantial completion. Installer Qualifications: 1. "Provide" means the Contractor shall "furnish and install" work and/or equipment. "Concealed" means hidden from sight in chases. humidity. Do not install products under environmental conditions outside manufacturer's absolute limits. B. Preparation instructions and recommendations. that all work installed shall be free from any and all defects in workmanship and materials. Laws. Submit shop drawings and Product Data grouped to include complete submittals of related systems. hung ceilings. Include methods for maintaining installed products. the Owner's Representative shall have the work done and charge the cost of the work to the Contractor. Furnish manufacturers written warranties for all equipment. valves. B. in crawl spaces or buried. 2. durability or longevity. Contractor shall guarantee.8 DELIVERY. without cost to the Owner. E.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15300 (cont. the Contractor shall.10 WARRANTY A.com GL-7. "FPC" means the Fire Protection Contractor. Fire Protection Contractor shall be licensed by the State in which the project is located authorized to furnish and install fire protection systems. Maintain environmental conditions (temperature. Store products in manufacturer's unopened packaging until ready for installation. "Exposed" means not installed underground or "concealed" as defined above. any defects in workmanship. that all apparatus shall develop capacities and characteristics specified. B. Product Data: Manufacturer's data sheets on each product to be used. 2 to 12 inches (51 to 305 mm): 300 PSI (2. Individually leak tested by the manufacturer using air-under-water or hydrostatic pressure. Central. Cast ductile conforms to ASTM A-536 Ductile Iron to Grade 65-45-12. Provide fire stopping assemblies as required by Section 07840 . c. a. B. Email: gwieczerza@anvilintl. braid(s). Model ANVL8 (+/-8 inches (203 mm) movement). In fire protection systems provide pipe loop that is Factory Mutual tested and approved for use in fire protection piping systems. Valves and Fittings for Fire Protection Systems part 2 products 2. Refer to Section 15050 for fire protection piping material. Model ANVL2 (+/-2 inches (51 mm) movement). 4. Anvil Star Tri-Flex Loop as manufactured by Anvil International.2 mm) shall be integrally seal-welded using a 100 percent circumferential. 300 PSI (2. b. or pre-approved equal.Firestopping. Copper Piping: 1.4 PIPING A. Provide access panels as required by Section 08310 . Couplings for Fire Protections Systems . Acceptable Manufacturer: Anvil International. The corrugated metal hose. a. which is located at: 110 Corporate Dr.5 times their maximum rated working pressure and a minimum 4:1 (burst to working) safety factor. Type: Refer to schedule on drawings for head type required for different building areas. 2. and sizes 4 inches to 12 inches (102 mm to 305 mm) ID shall be FM Approved for 175 psi (1.com GL-7. "C" Style Gaskets (DRI-SEAL). Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15300 (cont. or Flush Gap Gasket.6 FIRESTOPPING MATERIALS A. d. Portsmouth. c.1 MANUFACTURERS A. Tamper resistant screws shall be provided to attach the cover of the actuator. Requests for substitutions will be considered in accordance with provisions of Section 01600. C. 2. plus rotation about those axes) simultaneously. 2 to 12 inches (51 to 305 mm). Expansion Compensation Loop: 1. 2. End fittings shall be selected per application.5 ACCESS PANELS A.Gruvlok UL/ULC listed and/or FM approved.2 MPa) working pressure at ambient temperature.) 2. 90 degree elbows and tees in 2 to 8 inches (51 mm to 203 mm) or Gruvlok standard pattern fittings.anvilintl. Steel Piping: 1.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Pipes. A flexible pipe loop that absorbs and compensates for multi-plane movements simultaneously while reduce piping stress. Viking. Web: www. NH 03801. Fax: 603-422-8033. B. Reliable or equal.com. UL/ULC listed and FM approved grooved-end.12 221 . full penetration TIG welds. E. Grooved Butterfly Valve: Gruvlok Figure AE-7722-3A. Substitutions: Not permitted. Fire-RiteSYMBOL 212 fittings are UL/ULC listed and FM approved.048 inch (1.2 MANUFACTURED UNITS A.1 MPa) working pressure at ambient temperature. Manufacturer: 1.7 EQUIPMENT SUPPORTS A. Sizes 2 inches to 3 inches (51 mm to 76 mm) ID shall be FM Approved for 300 psi (2. Refer to Section 15050 for fire protection piping material. 2. Check Valves: Gruvlok Figure 78FP. Suite 10 . Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. D. b. 3.anvilintl. Design for pressure testing to 1. Fabricate equipment supports not provided by equipment manufacturer from structural grade steel meeting requirements of Section 05120 www. C. Construction shall be 3 equal length sections of annular corrugated stainless steel close-pitch hose (made in USA) with stainless steel over braid (made in USA) that will absorb or compensate for pipe movements in all 6 degrees of freedom (3 coordinate axes.1 MPa) rated UL/FM approved grooved-end with two (2) switches. one is a supervisory switch and the other is an auxiliary switch.1 MPa) rated. 2. 2 to 10 inches (51 mm to 254 mm). Fittings are painted to industry specification and are available galvanized.com B. Tel: 603-422-8000. 2. Grooved Fittings for Fire Protection Piping Systems: Gruvlok Fire-Rite short pattern fittings. and a stainless steel ring-ferrule/band (material gauge not less than . Figure 7000 (Flexible) and 7400 (Rigidlok) Grade "E" EPDM Type A. Type E EPDM. Model ANVL4 (+/-4 inches (102 mm) movement). 2.Access Doors and Panels.3 SPRINKLER HEADS A. Warranty: Provide a 3-year product warranty when installed in accordance with all specifications and installation instructions as described in the Anvil Tri-Flex Loop Installation and Maintenance Instructions. B. C. Contractor shall verify and obtain fire flow test data required for design. H. B. Compensation loops shall be prepared for shipment using a cut-to-length metal shipping bar.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15300 (cont. Contractor shall inspect and take note of existing conditions along with the Owner's Representative to avoid disputes regarding the condition of existing surface before work began.com GL-7.anvilintl. part 3 execution 3. Provide templates to ensure accurate location of anchor bolts. A. Fire Protection Contractor shall sublet installation work to subcontractors specifically skilled in the construction of the surfaces involved.2 PREPARATION A. C. notify Architect of unsatisfactory preparation before proceeding. Provide openings as necessary to permit installation of piping or any other part of work under this Section. B. B. to maintain the manufactured length during shipping. Contractor shall confer with the other Project Contractors with respect to access panel locations and shall. wherever practicable. or other specialties installed behind wall or above ceiling surfaces. J. Openings through existing concrete shall be core-drilled or saw cut. E. valves. tacked securely between the elbows of the two parallel legs. This Contractor shall be responsible for establishing sizes and locations of all openings and lintels in new work and to transmit this information to the Contractor whose work is involved at such time as to avoid cutting and patching. Contractor shall remove all markings and labels from access panels. Valves and Fittings for Fire Protection Systems Structural Steel. H. Comply with the manufacturer's requirements for proper installation of fire stop materials to obtain the required fire and/or smoke rating. Clean surfaces thoroughly prior to installation.3 INSTALLATION A. F. In event holes must be provided through reinforced concrete.) 2. L. G.12 . Provide all openings and set all sleeves in cooperation with Contractors whose work is affected thereby. C. Cutting or drilling thru structural beams or joists is not permitted. The FM Approved and UL Listed Seismic Wire/Cable assemblies conform to the requirements of the ASCE (American Society of Civil Engineers) guidelines for structural applications of wire rope. N. D. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. in that the cable is pre-stretched and the permanent end fittings maintain the break strength of the cable with a safety factor of two. Shipping bar must be removed prior to system start-up. E. Lay-in acoustical tee bar ceilings and snap-in removable metal pan ceilings shall be considered adequate for access. Install in accordance with manufacturer's instructions. 3. Caulk opening between pipe and sleeve with fire barrier sealant. Do not begin installation until substrates have been properly prepared. M. K. Compensation loop hanger assembly kit shall be used to support and hang the loop.1 EXAMINATION A. Submit calculations with shop drawings. G. 222 www. 3. they shall be carefully drilled so as to avoid spalling and unnecessary damage of weakening of any structural member. D.4 COMPENSATION LOOPS A. Provide sleeves for piping penetrating floor and masonry walls. I. If substrate preparation is the responsibility of another installer. All patching shall match adjacent surfaces. Obtain Architect's approval before providing openings through concrete or masonry in place and then proceed as directed. Penetrations through fire and/or smoke rated construction shall be sealed to maintain the rating of the construction in which they occur. F. Contractor shall be responsible for damage to finished work resulting from cutting or drilling required because of neglect of Contractor to provide accurate and sufficient information. Provide access panels for access to equipment. group devices in such a manner so as to eliminate as many panels as possible.8 EQUIPMENT ANCHOR BOLTS AND TEMPLATES Pipes. chopping or breaking out will not be permitted. 3. Section 15500 .Piping Specialties. Section 07840 .5 SPRINKLER HEADS A.Hangers and Supports. the Contractor shall go over all work and clean equipment. Contractor shall be responsible for testing and certification of systems and ordering inspections as required by authorities having jurisdiction. main piping and valves as indicated on the drawings.Firestopping. C. Protect installed products until completion of project. 3. B. END OF SECTION section 15400 part 1 General 1. 1. apply paper cover over sprinkler heads to ensure the head and escutcheons do not get coated. C.2 RELATED SECTIONS A.anvilintl. fixtures. Section 08310 .12 223 . repair or replace damaged products before Substantial Completion.Basic Materials and Methods and Section 15500 .6 TESTS AND INSPECTIONS A. Valves and Fittings for Fire Protection Systems 3. B. D. E. grilles and any other obstructions in ceiling. Couplings shall not be galvanized unless system is exposed to a corrosive environment. Galvanized fittings to be used with galvanized pipe. 1. www. Section 15060 . Copper fittings shall be 99.4 SYSTEM DESCRIPTION A. Plumbing requirements. 1. Center sprinkler heads in ceiling tile and provide piping offsets as required. Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) SP-127 Bracing for Piping Systems Seismic-Wind-Dynamic Design. 4. C.1 SECTION INCLUDES A. C. 3. Provide mountable metal box of spare heads with proper wrench for head replacement. Touch-up. Section 15050 . Grooved products for steel and copper plumbing systems shall be used. B. 2. and related appurtenances and piping. Where ceiling is to be painted or sprayed. Refer to Section 15050 .Basic Mechanical Methods and Materials.Piping Specialties for related materials. E.3 RELATED SECTIONS A.) 3. Install sprinkler heads to coordinate with all lights. Remove protective paper cover after painting or spraying is completed.7 PROTECTION A. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15300 (cont. Inspections shall be made by the Owner's authorized representative and inspectors having jurisdiction. Locate sprinkler heads. and leave them clean and in complete working order at final completion of the project. Pipes. Selection.Access Doors and Panels. D. Valves and Fittings for Plumbing Systems 1.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Pipes. All tests shall be conducted in the presence of and to the satisfaction of the Owner or an authorized representative.9 percent lead free.com GL-7. Schedule 10 Type 304 or 316 grooved stainless steel pipe and grooved stainless steel fittings shall be used in conjunction with copper systems 8 inch (203 mm) diameter and above. Application. B. After all tests have been made and the systems pronounced to be satisfactory. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 1. AND HANDLING A. durability or longevity. 2. Certifications: 1. "Exposed" means not installed underground or "concealed" as defined above. A copy of the current certificate shall be available upon request. E. upon request. Store products in manufacturer's unopened packaging until ready for installation. "Or equivalent" means to possess the same performance qualities and characteristics and fulfill the utilitarian function without any decrease in quality. and pay all fees and sales taxes as required.) Pipes. Valves and Fittings for Plumbing Systems B. and ventilation) within limits recommended by manufacturer for optimum results. Submit under provisions of Section 01300.9 PROJECT CONDITIONS A. 1. products. Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. minimum size 6 inches (150 mm) square. and accessories in a single submittal. 1. Product Data: Manufacturer's data sheets on each product to be used. B. Contractor Design Requirements: 1. and establish condition and completeness of substrate. G. C. Review manufacturer's installation instructions and manufacturer's warranty requirements. 1. "Concealed" means hidden from sight in chases. and precautions against cleaning materials and methods detrimental to finishes and performance. Verification Samples: For each finish product specified. Submit shop drawings and [ Product Data ] grouped to include complete submittals of related systems. D. parts and assemblies. Shop Drawings: 1. and patterns. shafts. "Provide" means the Contractor shall "furnish and install" work and/or equipment. Incorporate in construction pipe hangers and supports to manufacturer's recommendations utilizing manufacturer's regular production components. "Piping" includes all pipe. and materials used with solvent-based materials.12 . Manufacturing facilities shall be registered to ISO 9001:2008 and assessed ISO 9001:2008 standard. Laws. Store and dispose of solvent-based materials. color. C.5 SUBMITTALS A. in accordance with requirements of local authorities having jurisdiction. Warranty: Warranty documents. F. G. Conduct pre-installation meeting to verify project requirements. F. 1. and other supports and accessories related to such piping. Maintain environmental conditions (temperature.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15400 (cont. Ordinances and Regulations. two samples. Manufacturer Qualifications: 1. and post all bonds incident thereto. and the requirements of the National Fire protection Association. representing actual product. E. Do not install products under environmental conditions outside manufacturer's absolute limits. 2. STORAGE. including: 1. 224 www. "FPC" means the Fire Protection Contractor. hangers.anvilintl. humidity. hung ceilings. C.6 QUALITY ASSURANCE A. Installer Qualifications: 1.8 DELIVERY. Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section. valves. Contractor shall obtain all necessary permits and licenses pertaining to this Division (expense borne by the Contractor) and comply with Municipal and State Codes. D. Closeout Submittals: 1. two complete sets of color chips representing manufacturer's full range of available colors and patterns. B. Include methods for maintaining installed products. coordinate with other trades. Preparation instructions and recommendations. Installation methods.7 DEFINITION A. B. Selection Samples: For each finish product specified. in crawl spaces or buried. "Fire Protection Work" is all of the work Indicated or required by the Contract Documents. embedded in construction. fittings. furred spaces. Certificates shall be furnished only as required by specific codes.com GL-7. B. Sizes 2 inches through 20 inches (51 mm through 508 mm) are rated at 300 psig (2. 5. E.1 MANUFACTURERS A. or as otherwise specified. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2. Combination rigid. 8. Flexible or other style couplings designed for axial motion or other movements shall be supported in strict accordance with factory recommendations. Grooved Couplings for Copper Tube Systems: Coupling working pressure not to exceed 300 psig (2. Hot dipped galvanized fittings shall conform to ASTM A-153. Bolts and nuts shall be zinc electroplated. Valves and Fittings for Plumbing Systems 1. Grade "EP" EPDM gasket. Material conformance to grooved industrial standards ASTM D-2000. Contractor shall guarantee. B. installations below . installations above 150 degrees F (66 degrees C) and installations that are subject to temperature cycles. 3. 3. 4. noise suppression and seismic tremor. Sizes 1 inch to 30 inches (25 mm to 762 mm): Gruvlok Style 7401 (Rigidlok) couplings shall be used including style 7012 flange adapters. 2.anvilintl. D. Suite 10 . 3. Gruvlok Xtreme Lubricant. Tel: 603-422-8000. Grade "E" EPDM gaskets are standard.0 MPa). Segmental welded fittings shall conform to ASTM A-53. Coatings shall be Standard (Orange) Alkyd-enamel rust inhibiting lead free paint.com B.anvilintl. during the period of one year. and outlet couplings shall be used for vibration. www. 2. without cost to the Owner. Figure 7012: Conforms to ANSI class 125 or 150 lb (57 or 68 kg). that all work installed shall be free from any and all defects in workmanship and materials.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Pipes. 9. Email: gwieczerza@anvilintl. Gruvlok Xtreme lubricant shall be used to insure proper gasket installation.) part 2 products 2. B. remedy such defects within a reasonable time as specified in notice from the Owner's Representative. Flanges in Figures 7012 and 7013 are designed with internal anti-rotation "tines" and are designated as a rigid connection. Portsmouth. material or performance appear. 7. the Contractor shall. but other gasket materials are available. C. Figures 7012 and 7013 flange adapters require sealing rings when used with certain flanged products. Acceptable Manufacturer: Anvil International.12 225 . 3. Gruvlok Style 7001 (Flexible) couplings shall be used for vibration attenuation and noise suppression at equipment locations. Copper Systems: Gruvlok Xtreme Lubricant. Fittings shall conform to Cast Ductile ASTM A-536 or Cast Malleable ASTM A-47. 6. Coupling Track Head Bolts shall conform to ASTM A-183 Grade 2.0 MPa). Material: 1.com. and above 150 degrees F (66 degrees C) and systems subject to continuous cycle temperature changes: Gruvlok Xtreme Lubricant. 2. Gaskets: Gruvlok Product Grade "E" EPDM pressure responsive design for all water and oil free air service. Substitutions: Not permitted. 3. NH 03801. Furnish manufacturers written warranties for all equipment. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. the Owner's Representative shall have the work done and charge the cost of the work to the Contractor. 3. from the date of substantial completion. 1. which is located at: 110 Corporate Dr. Fax: 603-422-8033. 1. a. Couplings and Grooved Flange Adapters shall conform to ASTM A-536 Ductile Grade 65-45-12 or to ASTM A-47 Malleable Grade 32510. any defects in workmanship. to the Owner's Representative. C. Clamp type couplings shall be used for branch outlets. and that if. Temperature operating range is -40 degrees to +230 degrees F (-40 degrees C to 110 degrees C). 2. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15400 (cont. Grooved Couplings for Steel Pipe Systems and other Approved Piping: 1. in writing. EPDM gaskets are color coded green. stating effective date of Warranty. DRI-SEAL Fire Protection Gaskets: Standard Gruvlok lubricants. 4. Grooved Flange Adapters: Flange adapters to transition from flange to groove with no nipple shall be Gruvlok Fig 7012 or Figure 7013: 1. 2. F. Environments below -20 degrees F (-28 degrees C). Hex nuts shall confirm to ASTM A-563 Grade A. Gasket Lubricant: Coupling gaskets except where noted shall be lubricated with approved lubricant. Standard coupling gaskets for building services shall be Grade "EP" EPDM conforming to ASTM D-2000 with operating temperature range from -40 degrees F to +250 degrees F (-40 degrees C to 121 degrees C).20 degrees F (-28 degrees C). Web: www. 2. 4. Gruvlok Xtreme Lubricant shall be used for all copper system installations. Forged steel fittings shall conform to ASTM A-234 or A-106 Grade B.com GL-7. 1. In default thereof. that all apparatus shall develop capacities and characteristics specified.2 FITTINGS A. Gruvlok style 6400 rigid coupling and style 6084 flange adapter.10 WARRANTY A. flexible. Couplings and Wrought Copper Fittings shall be NSF. and Clamp-T Cross Figure 7047. Grooved Fittings for Steel Piping Systems . Shall inhibit the formation of a galvanic cell between dissimilar metals. Outlet Couplings: Shall be Gruvlok Figure 7042 with grooved or threaded outlets.2 KPa to 2. Flanged Gland: Cast iron.Shall be Gruvlok cast ductile. Fittings shall be coated with an Alkyd-enamel non-toxic paint. 1. B. 6. 3.com GL-7. comply with ASTM A126. 1. 5.72 MPa). Materials conform to ASTM A-536 and A-47.0 KPa) UL/ULC listed and FM approved. 1. 7. 1. Branch Outlets: Shall be Gruvlok Clamp-T Styles 7045 and 7046. 2. Working pressure to 500 psi (3. 5.3 GROOVED CONNECTION FLOW CONTROL VALVES A. Gaskets for Industrial and Other Piping Systems: Gaskets with different media products shall be provided with industrial grade gaskets as scheduled. 2. Valves and Fittings for Plumbing Systems b. comply with ASTM A395 or ASTM A536. forged steel. 2. Material conforms to ASTM A-126 Class A Cast Iron.Model FTV-A. Track Head Bolts and Hex Nuts: Couplings shall be furnished with heat treated. Stem: Bronze. J. H. 11. non-asbestos packing. 4. comply with ASTM A395 or ASTM A536. 4.2 KPa) with bolts fully torque to factory recommend torque requirements on plain-end or beveled standard wall steel pipe and Gruvlok Plain-End fittings. Fittings are cast or forged steel. G. Cast ductile conforms to ASTM A-536 or cast malleable iron conforms to ASTM A-47. Disc: Cast iron. 226 www.300 psi (1. 10. Size range is 2 inches to 16 inches (51 mm to 406 mm) diameter. L. Gruvlok Balancing Valves . 300 psig (2 MPa). Hex nuts shall be carbon steel conforming to ASTM A-563 Grade A. Size 24 inches (610 mm) is rated at 250 psig (1. 3. N. Branch outlets from 1/2 inch to 2 inches (13 mm to 51 mm) diameter. Gruvlok Tri-Service Valves . Run Sizes 2 inches to 8 inches (51 mm to 203 mm). Size range is 1 inch to 2-1/2 inches (25 mm to 64 mm) diameter: Plain End "Sock-it" Method: Gruvlok Sock-it fitting series 7100 through 7107. 2. 3. 7048 and 7049 with grooved or threaded outlets. I. Run sizes 1-1/2 inches to 6 inches (38 mm to 152 mm). 8.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15400 (cont. oval neck track head bolts conforming to ASTM A-183 Grade 2. K. Spring: 302 stainless steel.) Pipes. Grooved Copper Fittings: Gruvlok Wrot Copper fittings per ASTM B-75 and ANSI B-16. Copper fittings shall be 99. Di-Electric Insulated Pipe Connections: Di-LOK Figure 7091 grooved by grooved insulating nipple. M. Working pressures from 175 . alloy C12200. Size: As indicated on drawings. Housing: Steel tube to comply with ASTM A513.12 . Bolts shall meet minimum tensile strength of 110. Size range is 3/4 inch to 6 inches (19 mm to 152 mm) diameter. 4. Body and Yoke: Ductile iron. Liner: Polypropylene to ASTM D4140. 4.22. 1.000 psi (758 KPa). Seat: Bronze. Fittings match coupling working pressure. Plain End Couplings and Fittings: Gruvlok Roughneck coupling Style 7005 and plain-end fittings to match. Operating Temperature -40 degrees F to +230 degrees F (-40 degrees C to 100 degrees C).anvilintl. Stem Guide: Ductile iron. Gruvlok Tri-Service Valves . comply with ASTM A126.9 percent lead free. comply with ASTM B21. Sizes 1 inches to 30 inches (25 mm to 762 mm) diameter: a. C. Seat-Guide: Bronze. Packing: Graphited. Disc Guide: Cast iron. Bolts and nuts shall be zinc electroplated. 9. 2. 1. 3. Designated as a bolted-on positive pipe engagement branch outlet. Branch outlets from 1/2 inch to 3 inches (13 mm to 76 mm) diameter. Figure 7013: 2 inches through 12 inches (51 mm through 305 mm) available for ANSI class 250 or 300 lb (113 kg or 136 kg) bolt pattern and is rated at 750 psig (5 MPa).Model GBV-S (Soldered).Model FTV-S. 1. 5. Other fittings are schedule 80 or lightwall as scheduled. Zinc electroplated fittings conform to ASTM B-633. Intended for working pressures 300 to 750 psig (2. Plumbing Code approved and UL/ULC listed. Forged steel conforms to ASTM A-234. malleable. 2. b. and/or segmental welded steel fittings.5 KPa). Working pressure shall be 500 psig minimum. 2. Segmental welded conforms to ASTM A-53. c. 2. comply with ASTM B584. comply with ASTM A126. Standard Fittings shall be schedule 40 or standard wall.0 KPa to 5. Hot Dip Galvanized fittings conform to ASTM A-153. Valves and Fittings for Plumbing Systems D. Do not begin installation until substrates have been properly prepared.Nitrile. B. Type and Description: Y-style globe valve with 4 full-turn adjustment. Grade 65-42-12. 5. F.6 FIRESTOPPING MATERIALS A.Model GBV-G (Grooved-End Straight). Provide access panels as required by Section 08310 . Grade: Grade T . Refer to Section 15050 for piping material. www.1 EXAMINATION A. Clean surfaces thoroughly prior to installation. Refer to Section 15050 for piping material. Submit calculations with shop drawings. Refer to Section 15050 for piping material. 9. D.Fluoroelastomer. 1.Access Doors and Panels. 4. Plastic Piping: 1. Size: As indicated on drawings. 3. Stainless Steel Piping: 1.4 PIPING A. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15400 (cont. C. B. E. 2. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.anvilintl. E. comply with ASTM A536. Provide sleeves for piping penetrating floor and masonry walls. Provide openings as necessary to permit installation of piping or any other part of work under this Section. Steel Piping: 1. Grade: Grade O . Body Coating: Epoxy. 7.12 227 .8 EQUIPMENT ANCHOR BOLTS AND TEMPLATES A. 3. Copper Piping: 1. Grade 65-42-12. Disc: Ductile iron.5 ACCESS PANELS A. Grade: Grade E . 2.2 PREPARATION A. Gruvlok Balancing Valves . C. 2. Gruvlok Balancing Valves .EPDM. Upper and Lower Shaft: Type 416 stainless steel.com GL-7. part 3 execution 3. 3. comply with ASTM A536. Provide fire stopping assemblies as required by Section 07840 . 2. Body: Ductile iron. Refer to Section 15050 for piping material. 2. with positive shutoff and micrometer type handwheel adjustment.7 EQUIPMENT SUPPORTS A.Firestopping.) 2. 1. Body Coating: Nylon.Model GBV-T (Threaded). Material: Cast bronze. Gruvlok Balancing Valves . F. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Size: As indicated on drawings. If substrate preparation is the responsibility of another installer. Fabricate equipment supports not provided by equipment manufacturer from structural grade steel meeting requirements of Section 05120 Structural Steel. Steel Piping: 1.Model GBV-A (Grooved-End Angle). Provide templates to ensure accurate location of anchor bolts. Refer to Section 15050 for piping material. notify Architect of unsatisfactory preparation before proceeding. Refer to Section 15050 for piping material. 8. B.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Pipes. Provide tamperproof memory stop. Aluminum Piping: 1. 2. D. pressure differential ports on both sides of the valve. 6. solder valve body in line using 95/5 solder. Mount valve to a spool piece on the discharge side of the pump. Install in accordance with manufacturer's instructions. Contractor shall inspect and take note of existing conditions along with the Owner's Representative to avoid disputes regarding the condition of existing surface before work began. Install valve-bonnet assembly into body. 3. as this will allow system sediment to accumulate in the ports. 2. Spool piece required is based on a minimum recommended space of 12 inches (305 mm) for pump sizes 2 inches by 2 inches (51 mm by 51 mm) to 6 inches by 6 inches (152 mm by 152 mm) and 24 inches (610 mm) for pump sizes 8 inches by 8 inches (203 mm by 203 mm) to 12 inches by 12 inches (305 by 305 mm). Specialty piped systems. Section 15050 . 4.5 PROTECTION A. Leave sufficient clearance around valve for valve removal or repair. locate valves at least 5 pipe diameters downstream from any fitting and at least 10 pipe diameters downstream from a pump. drain ports and handwheel. 4. 228 www. Mount valve to flanged equipment using Gruvlok Flange Adapter or industry standard grooved coupling. Balancing Valves . Valve body has been designed to handle the weight of the pump on vertical in-line installations. Install valves with flow in the direction of the arrow on the valve body.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15400 (cont.1 SECTION INCLUDES A. 1. Do not mount valve directly to pump to avoid causing undesirable noise in the system. B.Basic Mechanical Methods and Materials.Model GBV-G (Grooved-End Straight). 8. Provide easy access to probe metering ports (PMPs). Install valves in horizontal or vertical piping as indicated. repair or replace damaged products before Substantial Completion. The valve body is not designed to support the piping weight. Openings through existing concrete shall be core-drilled or saw cut. making sure non-asbestos gasket is in place. Valves and Fittings for Plumbing Systems E. Touch-up. Install valve in the direction of flow arrows on valve body. GBV-A (Grooved-End Angle): 1. suitable for system pressure and temperatures encountered. Do not install metering ports below the pipe (pointing down). GBV-T (Threaded).Model GBV-S (Soldered). Provide pipe supports under valve and strainer bodies. 5. For solder applications. Metering ports and body/drain plugs may be interchanged for improved accessibility. Tri-Service Valves . This Contractor shall be responsible for establishing sizes and locations of all openings and lintels in new work and to transmit this information to the Contractor whose work is involved at such time as to avoid cutting and patching.anvilintl.Access Doors and Panels. To ensure accuracy of measurement of GBV-S.12 . Globe Valves . 7. B. 5. Install no fittings within 2 pipe diameters downstream of valve. GBV-T. 3. D. All patching shall match adjacent surfaces.Models FTV-S.Firestopping. GBV-G and GBV-A valves. Section 15060 . Section 07840 . Section 08310 .2 RELATED SECTIONS A. 6. F. 9. H. B.Hangers and Supports. Support piping by hangers.) Pipes. END OF SECTION section 15500 Piping Specialties part 1 General 1. 6. 3. 3.3 INSTALLATION A. 2.4 VALVE INSTALLATION A. 3. G. C. Protect installed products until completion of project. FTV-A: 1.com GL-7. Warranty: Warranty documents. 3. Ordinances and Regulations.3 REFERENCES A. Grooved products for steel and copper piping specialty systems shall be used. "Exposed" means not installed underground or "concealed" as defined above. establish condition and completeness of substrate. 1. Submit shop drawings and [ Product Data ] grouped to include complete submittals of related systems. Refer to Section 15050 . two complete sets of color chips representing manufacturer's full range of available colors and patterns. C. Manufacturing facilities shall be registered to ISO 9001:2008 and assessed to ISO 9001:2008 standard. Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. representing actual product. Application. Galvanized fittings to be used with galvanized pipe. Shop Drawings: 1. parts and assemblies. Review manufacturer's installation instructions and manufacturer's warranty requirements. 1. and patterns. C. Contractor Design Requirements: 1. B. American Society of Mechanical Engineers (ASME) B31. F. D. upon request. hung ceilings. 1. Contractor shall obtain all necessary permits and licenses pertaining to this Division (expense borne by the Contractor) and comply with Municipal and State Codes. Couplings shall not be galvanized unless system is exposed to a corrosive environment. E. Installer Qualifications: 1. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15500 (cont. G. American Society of Mechanical Engineers (ASME) B31. E.Basic Materials and Methods for related materials. Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section. and accessories in a single submittal. products. Laws. Incorporate in construction pipe hangers and supports to manufacturer's recommendations utilizing manufacturer's regular production components. B. 2. A copy of the current certificate shall be available upon request. hangers. 2. B. Include methods for maintaining installed products. in crawl spaces or buried. Certifications: 1. Conduct pre-installation meeting to verify project requirements. 1.1 .Chemical Plant and Petroleum Refinery Piping.9 percent lead free. including: 1. two samples.6 QUALITY ASSURANCE A. "Concealed" means hidden from sight in chases. and other supports and accessories related to such piping. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Submit under provisions of Section 01300. and the requirements of the National Fire protection Association.Power Piping (SI Edition). color.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Piping Specialties 1. and pay all fees and sales taxes as required.4 SYSTEM DESCRIPTION A.7 DEFINITION A. "Or equivalent" means to possess the same performance qualities and characteristics and fulfill the utilitarian function without any decrease in www.) 1. C. B.5 SUBMITTALS A. Manufacturer Qualifications: 1. "Piping" includes all pipe.12 229 . embedded in construction. 2. coordinate with other trades. C. minimum size 6 inches (150 mm) square. Closeout Submittals: 1. and post all bonds incident thereto. valves. B. "Fire Protection Work" is all of the work Indicated or required by the Contract Documents. Selection Samples: For each finish product specified. Installation methods. and precautions against cleaning materials and methods detrimental to finishes and performance. Selection. furred spaces. Verification Samples: For each finish product specified. D. Preparation instructions and recommendations. fittings.3 . Certificates shall be furnished only as required by specific codes. shafts.com GL-7. [ Product Data ]: Manufacturer's data sheets on each product to be used. Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) SP-127 Bracing for Piping Systems Seismic-Wind-Dynamic Design.anvilintl. Copper fittings shall be 99. 2.10 WARRANTY A. Grooved Ball Valve . Grooved Butterfly Valve: Gruvlok Series 7700 and Series 8000GR grooved butterfly valves.Shall be Gruvlok Series 7500. Two position handle standard. Do not install products under environmental conditions outside manufacturer's absolute limits. (Optional . that all work installed shall be free from any and all defects in workmanship and materials. Body .1 MANUFACTURERS A.Ductile Iron with EPDM encapsulation. Double "D" with gear operators. 1. Email: gwieczerza@anvilintl. Infinite position with memory stop for sizes 2 inches through 8 inches (51 mm through 203 mm). Bubble tight to 200-psig (1. to the Owner's Representative.1 KPa) cwp.) Piping Specialties quality. 1. Disc-to-stem attachment shall be made with splined stainless steel stems attached to disc by cold fusion process. and pneumatic or electric actuated for sizes 2 inches through 12 inches (51 mm through 305 mm). Fax: 603-422-8033.Shall be Gruvlok Series 7500B.Size range 14 inches to 24 inches (356 mm to 610 mm). Service usage for Balancing and On/Off service. available with standard nylon body coating or epoxy body coated.type 1 for sizes 8 inches to 12 inches (203 mm to 305 mm) only. durability or longevity. Sizes 1-1/2 inches to 4 inches (38 mm to 102 mm) are rated 300 psi (1.416 s/s. B. Low Torque. Body-Ductile.B.12 inches (51 mm to 305 mm).4 MPa). "Provide" means the Contractor shall "furnish and install" work and/or equipment. Tel: 603-422-8000. material or performance appear. Liner.anvilintl. Store and dispose of solvent-based materials. in writing. Rated for "Dead-end" service. Bubble tight at 300 psig (2. chain wheel. Exterior body coated with rust Inhibiting paint. Bi-directional flow. part 2 products 2. G.Series 7700 and 8000GR available in 2 position. Substitutions: Not permitted. Listed in accordance with MSS SP-67.Sizes 2 inches to 12 inches (51 mm to 305 mm).Ductile Iron ASTM 395 and Stainless Steel ASTM A351 CF8M. Grooved Bronze Ball Valve.Type 304 or 302 s/s to ASTM A-167. from the date of substantial completion.com. C. Sizes 2 inches to 6 inches.9 PROJECT CONDITIONS A. without cost to the Owner.Ductile Iron.9 KPa).com GL-7. Low Torque. Operating Temperature up to 230 degrees F (110 degrees C). 1.Nitrile Disc encapsulation) Operating temperature up to +180 degrees F (82 degrees C) and Grade O Fluoroelastomer.sizes 2 inches to 5 inches (51 mm to 127 mm) -. The Series 7500 is compliant with NACE MR01-75 when stainless steel trim is specified. and ventilation) within limits recommended by manufacturer for optimum results. remedy such defects within a reasonable time as specified in notice from the Owner's Representative. Meets MSS SP-72 body and 100 percent hydro pressure tested.12 . the Owner's Representative shall have the work done and charge the cost of the work to the Contractor. humidity.316 and 416 s/s. EPDM seat-to-stem. BFV Operators/Handles . in accordance with requirements of local authorities having jurisdiction. Disc/stem seals shall be triple redundant as follows: 1. Suite 10 . 3. EPDM O-rings in upper and lower shaft. any defects in workmanship.Slam) Check Valve: Shall be Gruvlok Series 7800. 10 position latch lock. Grade 1 . Aluminum Bronze or Stainless Steel. Trim . 3. Valve shall comply with extraction requirements of NSF/ANSI 6. STORAGE. Portsmouth. a.Standard EPDM or Buna N. Bronze upper and lower shaft bearings conforming to ASTM B438.Nickel-Plated Ductile. Series 8000GR: Butterfly Valve .1 MPa). Bearings: Upper and lower bearings Teflon reinforced. Disc. Operating temperature same as 7700 series. Series 7700: Butterfly Valve . Low torque operation. 1. 2. and materials used with solvent-based materials. RPTFE and Nylon Seats and fluorocarbon stem and body seals. Full port sizes 1-1/2 inches to 3 inches (38 mm to 76 mm) and standard port in the 4 inches (102 mm) version. Body: Cast Iron to ASTM A-126 CL.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15500 (cont. Operating temperature -40 degrees FSYMBOL 176 to + 230 degrees F (-40 degrees C to 110 degrees C). NH 03801. Acceptable Manufacturer: Anvil International.anvilintl. 2. 1. Sizes 2 inches to. Maintain environmental conditions (temperature. C. 300-psig (1. stating effective date of Warranty. Body and End Caps . Furnish manufacturers written warranties for all equipment. the Contractor shall. Rated for "Dead-end" service. Standard port design rated for 740 psig (5. 230 www. Web: www. Grooved (Non. Ball and Stemchrome plated carbon steel and 316 Stainless Steel. that all apparatus shall develop capacities and characteristics specified. during the period of one year. Store products in manufacturer's unopened packaging until ready for installation. B.2 MANUFACTURED UNITS A. F. Clapper. Requests for substitutions will be considered in accordance with provisions of Section 01600.8 DELIVERY. "FPC" means the Fire Protection Contractor. Contractor shall guarantee. AND HANDLING A. located at: 110 Corporate Dr. Trim . Disc.com B.9 KPa) WOG. Disc-to-valve body. In default thereof. or as otherwise specified. B. and that if. Cast bonze body with stainless 316 ball and PTFE Seats and Seals. 3 PIPING A. Body. J. magnets. Operating temperature -40 degrees F to +230 degrees F (-40 degrees C to 110 degrees C). Seat ring. threaded & flanged end. Refer to Section 15050 for piping material.Gruvlok Models GAV-15 rated 150 psig and GAV-30 rated 300 psig. D.) (1.2 mm perf. Grooved Strainers: Shall be Gruvlok Series 7260-T ("Tee" Type) or 758-G or 768-GF ("Wye" Type) strainers.9 KPa).Polypropylene to ASTM D4140. 1.6 EQUIPMENT SUPPORTS A. Sizes 1/2 inch to 12 inches (13 mm to 305 mm).4 ACCESS PANELS A. Rated for 200-psi (1. Body. E.). Provide templates to ensure accurate location of anchor bolts. Flexible Connectors: Sizes 2 inches to 12 inches (51 mm to 305 mm). 2.3 KPa) maximum working pressure. Center-guided plug.Type 302 or 304 s/s.Ductible 2 inches to 12 inches (51 mm to 305 mm) Malleable Iron ASTM A47 or Ductile Iron ASTM A536. Body.) Through 3 inches (76 mm).Access Doors and Panels. Housing.) With start-up #16 mesh pre-filter removable screen. 2. Fixed or portable meters available for differential pressure measurement. Fabricate equipment supports not provided by equipment manufacturer from structural grade steel meeting requirements of Section 05120 Structural Steel. 2. 2. D.0 KPa).5 FIRESTOPPING MATERIALS A. Positive shut-off.) Clapper. Bronze hinge pin bushings. twin-fold basket provides 100 percent of the projected pipe area for open flow. Rated working pressure 150 to 300 psi (1.sizes 6 inches to 12 inches (152 mm to 305 mm) . Proportional balancing. Steel Piping: 1. I. Refer to Section 15050 for piping material.Carbon steel to ASTM A-53 body for all sizes. Submit calculations with shop drawings. Tee Strainer Series 7260: Sizes 2 inches to 24 inches (51 mm to 610 mm). and various mesh sizes optional. Tamper-proof memory stop. Strainer Basket.Ductile. Provide fire stopping assemblies as required by Section 07840 . Wye Strainers 758-G & 768GF: Size range 2 inches to 12 inches (305 mm).12 231 . Aluminum Piping: 1. Operating temperature to 200 degrees F (93 degrees C).Same as Tee Series. Refer to Section 15050 for piping material. Strainer in-line. Triple Duty Combination Valves: Shall be Gruvlok "Tri-Service" (FTV-A/FTV-S) service valves. Size 14 inches (356 mm) and larger: Carbon Steel Pipe ASTM A53. C.Firestopping. E. Automatic Air Vents .Stainless steel Type 304-basket standard #12 mesh (1/16 inch perf.) (4.) (3. Clapper facing. Inhibits the formation of a galvanic cell between dissimilar metals. F. G. Horizontal or vertical service usage. Multi-turn adjustment. 100 percent Shell Test & Hydro Seat test pressure 100 percent.Ductile Iron. s/s and s/s w Buna Seat. Durlon Gasket.Ductile iron. Di-Electric Insulated Pipe Connections: Shall be Di-Lok Figure 7091 grooved by grooved insulating nipple. 2. 300 psig (1. Flow measurement ports on either side of valve body. Stainless Steel Piping: 1. Throttling flow indicator is standard. (Positive noiseless opening and closing) Plug activated at 1/4 to 1/2 psi (1723 Pa to 3448 Pa).6 mm perf.76 mm perf. Sizes 2-1/2 inches to 12 inches (64 mm to 305 mm). Copper Piping: 1. Differential Pressure MeterProvide CBV differential pressure meter/transducer as required.EPDM or Nitrile. Pressure differential read-out ports. Monel or other alloy baskets. Optional Trim. Bronze Seat. Plug and Bushing. Stainless steel tube and braid design. Grooved Suction Diffusers: Shall be Gruvlok Series 7250. Refer to Section 15050 for piping material.9 KPa) to a low 1 psi (28 inch water head) (6895 Pa). Services. H. Sizes 4 inches and larger standard with #6 mesh (1/8 inch perf.Bronze w/ Buna Seat. 300 psig (1. Horizontal or vertical service usage.9 KPa).com GL-7. Refer to Section 15050 for piping material. Calibrated Circuit (Setter) Balancing Valves: Shall be GBV-Gruvlok "Circuit Balancing" Valve. MSS SP-71 & SP-80. Grooved (Globe Type) Silent Check Valve: Shall be Gruvlok Series 400 G. www. 2.0 to 2. F. Liner. Service from 300 psi (1. Direct Flow readout. non-slam silent check and full throttling. Plastic Piping: 1. Replaceable clapper.9 KPa). spring. and hinge pin: . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15500 (cont.Combination shut-off.Steel Tube to ASTM A513. Basket.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Piping Specialties Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Iron hinge pin plugs and drain. Sizes 2 inches to 10 inches. B. Baskets. Sizes 2-1/2 inches to 16 inches (64 mm to 406 mm). Horizontal or vertical service usage.7 EQUIPMENT ANCHOR BOLTS AND TEMPLATES A. Provide access panels as required by Section 08310 . Carbon steel grooved. TrimMetal on Metal.anvilintl. Body. Blow-down and gage plug standard. Refer to Section 15050 for piping material. 300 psig (1. Steel Piping: 1.Stainless steel (3/16 inch perf. 1. Contractor shall inspect and take note of existing conditions along with the Owner's Representative to avoid disputes regarding the condition of existing surface before work began. F. B.com GL-7. H. Section 15050 .Hangers and Supports. Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) SP-127 Bracing for Piping Systems Seismic-Wind-Dynamic Design.Piping Specialties.2 RELATED SECTIONS A. B. This Contractor shall be responsible for establishing sizes and locations of all openings and lintels in new work and to transmit this information to the Contractor whose work is involved at such time as to avoid cutting and patching.1 EXAMINATION A. Selection. Openings through existing concrete shall be core-drilled or saw cut. Section 15500 . Grooved products for steel and copper heating and cooling systems shall be used. C. Section 15060 .Basic Materials and Methods and Section 15500 . D.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15500 (cont. All patching shall match adjacent surfaces. D. HVAC requirements. END OF SECTION section 15600 part 1 General 1.anvilintl. If substrate preparation is the responsibility of another installer.4 PROTECTION A.Firestopping. Provide openings as necessary to permit installation of piping or any other part of work under this Section.Piping Specialties for related materials. E. B.) Piping Specialties part 3 execution 3.4 SYSTEM DESCRIPTION A. 232 www. G. Do not begin installation until substrates have been properly prepared. Section 08310 . Protect installed products until completion of project. C.3 INSTALLATION A. E. repair or replace damaged products before Substantial Completion. Section 07840 . Provide sleeves for piping penetrating floor and masonry walls. Galvanized fittings shall be used with galvanized pipe. 3. Pipes. Refer to Section 15050 . B.Access Doors and Panels.12 . 1. Valves and Fittings for HVAC Heating and Cooling Systems 1. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 1.2 PREPARATION A.Basic Mechanical Methods and Materials. notify Architect of unsatisfactory preparation before proceeding.3 REFERENCES A. Touch-up. Application. 1.1 SECTION INCLUDES A. 3. Clean surfaces thoroughly prior to installation. Install in accordance with manufacturer's instructions. 3. Manufacturer Qualifications: 1. Submit under provisions of Section 01300. Warranty: Warranty documents. 1. A copy of the current certificate shall be available upon request. Store and dispose of solvent-based materials. Certifications: 1. and the requirements of the National Fire protection Association. coordinate with other trades.5 SUBMITTALS A. humidity. durability or longevity. Ordinances and Regulations. "Exposed" means not installed underground or "concealed" as defined above. Conduct pre-installation meeting to verify project requirements. B. including: 1. and accessories in a single submittal. "Concealed" means hidden from sight in chases. parts and assemblies. Copper fittings shall be 99. hangers. 3.9 percent lead free. Couplings shall not be galvanized unless system is exposed to a corrosive environment. 1. Do not install products under environmental conditions outside manufacturer's absolute limits.anvilintl. Store products in manufacturer's unopened packaging until ready for installation. and pay all fees and sales taxes as required. B. F. C. "Fire Protection Work" is all of the work Indicated or required by the Contract Documents. establish condition and completeness of substrate.7 DEFINITION A. in crawl spaces or buried. and ventilation) within limits recommended by manufacturer for optimum results.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Pipes. Certificates shall be furnished only as required by specific codes. 2. Contractor Design Requirements: 1. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Incorporate in construction pipe hangers and supports to manufacturer's recommendations utilizing manufacturer's regular production components. "FPC" means the Fire Protection Contractor. embedded in construction. 1. valves. B. "Piping" includes all pipe. and post all bonds incident thereto. [ Product Data ]: Manufacturer's data sheets on each product to be used.6 QUALITY ASSURANCE A. fittings. Include methods for maintaining installed products. C.) 1. and precautions against cleaning materials and methods detrimental to finishes and performance. Maintain environmental conditions (temperature. furred spaces. Valves and Fittings for HVAC Heating and Cooling Systems 2. shafts. E. in accordance with requirements of local authorities having jurisdiction.com GL-7. Laws. Contractor shall obtain all necessary permits and licenses pertaining to this Division (expense borne by the Contractor) and comply with Municipal and State Codes. Preparation instructions and recommendations. Shop Drawings: 1. "Provide" means the Contractor shall "furnish and install" work and/or equipment. Review manufacturer's installation instructions and manufacturer's warranty requirements. B.8 DELIVERY. Closeout Submittals: 1. hung ceilings. D. Schedule 10 Type 304 or 316 grooved stainless steel pipe and grooved stainless steel fittings shall be used in conjunction with copper systems 8 inch (203 mm) diameter and above. Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. Installer Qualifications: 1. D. C. 2. STORAGE. E. Submit shop drawings and [ Product Data ] grouped to include complete submittals of related systems.12 233 . and other supports and accessories related to such piping. www. Installation methods. Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section. and materials used with solvent-based materials. B. G. AND HANDLING A.9 PROJECT CONDITIONS A. upon request. 4. "Or equivalent" means to possess the same performance qualities and characteristics and fulfill the utilitarian function without any decrease in quality. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15600 (cont. Manufacturing facilities shall be registered to ISO 9001:2008 and assessed to ISO 9001:2008 standard. products. 1. 10 WARRANTY Pipes. Hot dipped galvanized fittings shall conform to ASTM A-153. Fax: 603-422-8033. Standard coupling gaskets for building services shall be Grade "EP" EPDM conforming to ASTM D-2000 with operating temperature range from -40 degrees F to +250 degrees F (-40 degrees C to 121 degrees C). 234 www. Grooved Couplings for Copper Tube Systems: Coupling working pressure not to exceed 300 psig (2. Flexible or other style couplings designed for axial motion or other movements shall be supported in strict accordance with factory recommendations. Copper Systems: Gruvlok Xtreme Lubricant. that all apparatus shall develop capacities and characteristics specified. material or performance appear. Material conformance to grooved industrial standards ASTM D-2000. the Contractor shall. without cost to the Owner. Valves and Fittings for HVAC Heating and Cooling Systems A. NH 03801. DRI-SEAL Fire Protection Gaskets: Standard Gruvlok lubricants. 4. Grade "EP" EPDM gaskets are standard. Couplings and Grooved Flange Adapters shall conform to ASTM A-536 Ductile Grade 65-45-12 or to ASTM A-47 Malleable Grade 32510. Email: gwieczerza@anvilintl. installations below . and outlet couplings shall be used for vibration. 8. Grooved Flange Adapters: Flange adapters to transition from flange to groove with no nipple shall be Gruvlok Fig 7012 or Figure 7013: 1. Combination rigid. installations above 150 degrees F (66 degrees C) and installations that are subject to temperature cycles. D. during the period of one year.com. Gruvlok Xtreme lubricant shall be used to insure proper gasket installation. Gruvlok Style 7001 (Flexible) couplings shall be used for vibration attenuation and noise suppression at equipment locations. Grooved Couplings for Steel Pipe Systems and other Approved Piping: 1. Hex nuts shall confirm to ASTM A-563 Grade A. 7. Suite 10 .com B. Web: www. 1. Forged steel fittings shall conform to ASTM A-234 or A-106 Grade B.anvilintl. Substitutions: Not permitted.) 1. or as otherwise specified. 2. Bolts and nuts shall be zinc electroplated. E. 3. Temperature operating range is -40 degrees to +250 degrees F (-40 degrees C to 121 degrees C). 2. the Owner's Representative shall have the work done and charge the cost of the work to the Contractor. Tel: 603-422-8000. to the Owner's Representative. 1. B. EPDM gaskets are color coded green and red. remedy such defects within a reasonable time as specified in notice from the Owner's Representative. 2. Fittings shall conform to Cast Ductile ASTM A-536 or Cast Malleable ASTM A-47. 5. 2. part 2 products 2. and above 150 degrees F (66 degrees C) and systems subject to continuous cycle temperature changes: Gruvlok Xtreme Lubricant. 4. C. 6. stating effective date of Warranty. Gruvlok Xtreme Lubricant. 3. noise suppression and seismic tremor. F. Contractor shall guarantee. and that if. flexible. 2. Acceptable Manufacturer: Anvil International. Environments below -20 degrees F (-28 degrees C).0 MPa). any defects in workmanship. 2. Sizes 1 inch to 30 inches (25 mm to 762 mm): Gruvlok Style 7401 (Rigidlok) couplings shall be used including style 7012 flange adapters. located at: 110 Corporate Dr. Furnish manufacturers written warranties for all equipment. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2. Figure 7012: Conforms to ANSI class 125 or 150 lb (57 or 68 kg). Clamp type couplings shall be used for branch outlets. 3. 1.2 FITTINGS A. Coatings shall be Standard (Orange) Alkyd-enamel rust inhibiting lead free paint.com GL-7. that all work installed shall be free from any and all defects in workmanship and materials. B. 4. Gruvlok Xtreme Lubricant shall be used for all copper system installations. from the date of substantial completion.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15600 (cont. Gasket Lubricant: Coupling gaskets except where noted shall be lubricated with approved lubricant. Figures 7012 and 7013 flange adapters require sealing rings when used with certain flanged products. C.anvilintl. 9. Gruvlok style 6400 rigid coupling and style 6084 flange adapter. 3. Flanges in Figures 7012 and 7013 are designed with internal anti-rotation "tines" and are designated as a rigid connection. 3. but other gasket materials are available. In default thereof.1 MANUFACTURERS A. in writing.20 degrees F (-28 degrees C). Material: 1. Portsmouth. Coupling Track Head Bolts shall conform to ASTM A-183 Grade 2.12 . Segmental welded fittings shall conform to ASTM A-53. Gaskets: Gruvlok Product Grade "EP" EPDM pressure responsive design for all water and oil free air service. Forged steel conforms to ASTM A-234. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15600 (cont. Trim . Branch Outlets: Shall be Gruvlok Clamp-T Styles 7045 and 7046. Branch outlets from 1/2 inch to 3 inches (13 mm to 76 mm) diameter. Plumbing Code approved and UL/ULC listed. 3. Disc/stem seals shall be triple redundant as follows: 1. M. Material conforms to ASTM A-126 Class A Cast Iron. (Optional .1 MPa). 2. Plain End Couplings and Fittings: Gruvlok Roughneck coupling Style 7005 and plain-end fittings to match. Operating Temperature -40 degrees F to +230 degrees F (-40 degrees C to 100 degrees C). Working pressure to 500 psi (3. 4. Run sizes 1-1/2 inches to 6 inches (38 mm to 152 mm). 2.22. Sizes 2 inches through 20 inches (51 mm through 508 mm) are rated at 300 psig (2. Bronze upper and lower shaft bearings conforming to ASTM B438. EPDM seat-to-stem. N. Low Torque.300 psi (1.Sizes 2 inches to 12 inches (51 mm to 305 mm). Size range is 1 inch to 2-1/2 inches (25 mm to 64 mm) diameter: Plain End "Sock-it" Method: Gruvlok Sock-it fitting series 7100 through 7107. oval neck track head bolts conforming to ASTM A-183 Grade 2. Grooved Copper Fittings: Gruvlok Wrot Copper fittings per ASTM B-75 and ANSI B-16.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Pipes. Copper fittings shall be 99. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.Ductile Iron. J.416 s/s. Track Head Bolts and Hex Nuts: Couplings shall be furnished with heat-treated. Fittings are cast ductile iron. 4. Service usage for Balancing and On/Off service. Bolts and nuts shall be zinc electroplated.Size range 14 inches to 24 inches (356 mm to 610 mm). malleable.Shall be Gruvlok cast ductile. Housing: Steel tube to comply with ASTM A513. Grooved Butterfly Valve: Gruvlok Series 7700 and Series 8000GR grooved butterfly valves. cast malleable iron or forged steel. Grooved Fittings for Steel Piping Systems . 2. Bubble tight to 200-psig (1.anvilintl. Disc-to-valve body. and/or segmental welded steel fittings. 5.9 percent lead free. Di-Electric Insulated Pipe Connections: Di-LOK Figure 7091 grooved by grooved insulating nipple. Sizes 1 inches to 30 inches (25 mm to 762 mm) diameter: a. Series 8000GR: Butterfly Valve . 2. Gaskets for Industrial and Other Piping Systems: Gaskets with different media products shall be provided with industrial grade gaskets as scheduled. 5. Body . Fittings shall be coated with an Alkyd-enamel non-toxic paint. 2. Operating temperature same as 7700 series.com GL-7. b. c. Aluminum Bronze or Stainless Steel. b. 2.0 KPa to 5. forged steel. 1.72 MPa).12 235 . Low Torque. Bubble tight at 300 psig (2. Hex nuts shall be carbon steel conforming to ASTM A-563 Grade A. 1. Couplings and Wrought Copper Fittings shall be NSF.0 KPa) UL/ULC listed and FM approved. 1. Rated for "Dead-end" service. 4. Cast ductile conforms to ASTM A-536 or cast malleable iron conforms to ASTM A-47. 3.Standard EPDM or Nitrile. Disc-to-stem attachment shall be made with splined stainless steel stems attached to disc by cold fusion process. ASTM A-47 or ASTM A-234. Designated as a bolted-on positive pipe engagement branch outlet. 7048 and 7049 with grooved or threaded outlets. Disc. Disc. 3. Run Sizes 2 inches to 8 inches (51 mm to 203 mm). Valves and Fittings for HVAC Heating and Cooling Systems a. Zinc electroplated fittings conform to ASTM B-633.5 KPa).type 1 for sizes 8 inches to 12 inches (203 mm to 305 mm) only.2 KPa) with bolts fully torque to factory recommend torque requirements on plain-end or beveled standard wall steel pipe and Gruvlok Plain-End fittings. Working pressures from 175 . Outlet Couplings: Shall be Gruvlok Figure 7042 with grooved or threaded outlets. Trim . Operating temperature -40 degrees F to + 230 degrees F (-40 degrees C to 110 degrees C).B. G. Size range is 2 inches to 16 inches (51 mm to 406 mm) diameter. Fittings match coupling working pressure. Bearings: Upper and lower bearings Teflon reinforced. Standard Fittings shall be schedule 40 or standard wall. 3. 3.Ductile Iron with EPDM encapsulation. Rated for "Dead-end" service. 1. 2. Body: Cast Iron to ASTM A-126 CL. Liner. K. Grade 1 . I. Intended for working pressures 300 to 750 psig (2. Size 24 inches (610 mm) is rated at 250 psig (1.) 2. L. Series 7700: Butterfly Valve . Operating Temperature up to 230 degrees F (110 degrees C).Nitrile Disc encapsulation) Operating temperature up to +180 degrees F (82 degrees C) and Grade O Fluoroelastomer.3 GROOVED CONNECTION FLOW CONTROL VALVES A. www. Shall inhibit the formation of a galvanic cell between dissimilar metals. 1. 2.4 MPa). Segmental welded conforms to ASTM A-53. 1.2 KPa to 2. alloy C12200. Other fittings are schedule 80 or lightwall as scheduled. Size range is 3/4 inch to 6 inches (19 mm to 152 mm) diameter. Figure 7013: 2 inches through 12 inches (51 mm through 305 mm) available for ANSI class 250 or 300 lb (113 kg or 136 kg) bolt pattern and is rated at 750 psig (5 MPa). a. Listed in accordance with MSS SP-67. and Clamp-T Cross Figure 7047. Hot Dip Galvanized fittings conform to ASTM A-153. available with standard nylon body coating or epoxy body coated. Materials conform to ASTM A-536. H. 300 psig (2 MPa).0 MPa). Working pressure shall be 500-psig minimum. Liner: Polypropylene to ASTM D4140. Bolts shall meet minimum tensile strength of 110.316 and 416 s/s. 1.000 psi (758 KPa). EPDM O-rings in upper and lower shaft.Nickel-Plated Ductile. Branch outlets from 1/2 inch to 2 inches (13 mm to 51 mm) diameter. 9 KPa) WOG. RPTFE and Nylon Seats and fluorocarbon stem and body seals. Size: As indicated on drawings. Seat: Bronze. 2. comply with ASTM A126. 1. comply with ASTM B584.Type 304 or 302 s/s to ASTM A-167. pressure differential ports on both sides of the valve. Grooved (Non. Sizes 1-1/2 inches to 4 inches (38 mm to 102 mm) are rated 300 psi (1. 9. Clapper. E. Grooved Three Way Diverter Valve .12 . G. Durlon Gasket.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15600 (cont. Body. Horizontal or vertical service usage.Ductile. Seat ring. Service from 300 psi (1. Seat: Ultra-high strength engineered resin. 2.Polypropylene to ASTM D4140. 11. Double "D" with gear operators. Valve shall comply with extraction requirements of NSF/ANSI 6. Gruvlok Tri-Service Valves . The Series 7500 is compliant with NACE MR01-75 when stainless steel trim is specified.) Pipes. comply with ASTM A126. Stem Guide: Ductile iron. Rated for 200-psi (1.sizes 6 inches to 12 inches (152 mm to 305 mm). 6. Gruvlok Balancing Valves . Type and Description: Y-style globe valve with 4 full-turn adjustment. Size: As indicated on drawings. s/s and s/s w Nitrile Seat. Body. Clapper facing.Series 7700 and 8000GR available in 2 position. 8. Full port sizes 1-1/2 inches to 3 inches (38 mm to 76 mm) and standard port in the 4 inches (102 mm) version. Low torque operation.Shall be Gruvlok Series 7500.com GL-7. Grooved Ball Valve . Meets MSS SP-72 body and 100 percent hydrostatic pressure tested. comply with ASTM A126.9 KPa) to a low 1 psi (28 inch water head) (6895 Pa). Clapper.Model GBV-S (Soldered). (Positive noiseless opening and closing) Plug activated at 1/4 to 1/2 psi (1723 Pa to 3448 Pa). Full port design rated for 600 psig (4.1 KPa) cwp.Model FTV-A. Di-Electric Insulated Pipe Connections: Shall be Di-Lok Figure 7091 grooved by grooved insulating nipples. D. Grooved Bronze Ball Valve. 3. 3.Model GBV-T (Threaded). 7. Housing. TrimMetal on Metal. 236 www. Liner. Plug and Bushing. Replaceable clapper. 10 position latch lock. .Model FTV-S. Sizes 2 inches to. Optional Trim.Slam) Check Valve: Shall be Gruvlok Series 7800. 5.3 KPa) maximum working pressure.anvilintl. Standard port design rated for 740 psig (5. 1.Model GBV-G (Grooved-End Straight). Spring: 302 stainless steel.Shall be Gruvlok Series 7500B.Model GBV-A (Grooved-End Angle). Stem: Bronze. 6. and hinge pin: . with positive shutoff and micrometer type hand wheel adjustment. 2.12 inches (51 mm to 305 mm).Ductile Iron. Sizes 2 inches to 6 inches. Disc: Bronze. 4. comply with ASTM B584. Gruvlok Tri-Service Valves . Packing: Graphited. Seat-Guide: Bronze. 300-psig (1. H. Inhibits the formation of a galvanic cell between dissimilar metals. Grooved Strainers: Shall be Gruvlok Series 7260-T ("Tee" Type) or 758-G or 768-GF ("Wye" Type) strainers.1 KPa) cwp. Grooved (Globe Type) Silent Check Valve: Shall be Gruvlok Series 400 G. Valves and Fittings for HVAC Heating and Cooling Systems 4. 2. 3.9 KPa). chain wheel. Sizes 2 inches to 10 inches. comply with ASTM A536.Bronze w/ Nitrile Seat. Body and End Caps . Gruvlok Balancing Valves . comply with ASTM B21.EPDM or Nitrile. Center-guided plug. Iron hinge pin plugs and drain. Flanged Gland: Cast iron. 100 percent Shell Test & Hydro Seat test pressure 100 percent. Gruvlok Balancing Valves . BFV Operators/Handles . Exterior body coated with rust Inhibiting paint. Meets MSS SP-72 body and 100 percent hydro pressure tested. and pneumatic or electric actuated for sizes 2 inches through 12 inches (51 mm through 305 mm). 5. 1. Disc: Cast iron. B. Provide tamperproof memory stop. Operating temperature to 200 degrees F (93 degrees C). Size: As indicated on drawings. 300 psig (1. 1. non-asbestos packing. Body: Ductile iron.9 KPa). Bi-directional flow. Cast bonze body with stainless 316 ball and PTFE Seats and Seals. Disc Guide: Cast iron. F. Bronze Seat. B. 1. Body and Yoke: Ductile iron.Steel Tube to ASTM A513.sizes 2 inches to 5 inches (51 mm to 127 mm) -.4 MANUFACTURED UNITS A.Ductile.Type 302 or 304 s/s. Material: Cast bronze. O-ring: Nitrile. 2. 10. comply with ASTM A395 or ASTM A536. spring. C. C. comply with ASTM A395 or ASTM A536. 4. Ball and Stem .Shall be Gruvlok Series FS7500 Stainless Steel body or FC7500 Carbon Steel Body 3-Way Diverter Valve. Gruvlok Balancing Valves . Bronze hinge pin bushings. Trim: Brass C-37700. Infinite position with memory stop for sizes 2 inches through 8 inches (51 mm through 203 mm).Ductile Iron ASTM 395 and Stainless Steel ASTM A351 CF8M. MSS SP-71 & SP-80.chrome plated carbon steel and 316 Stainless Steel. Two position handle standard. Operating temperature -40 degrees F to +230 degrees F (-40 degrees C to 110 degrees C). Sizes 2-1/2 inches to 16 inches (64 mm to 406 mm).Same as Tee Series.). G.7 FIRESTOPPING MATERIALS A. part 3 execution 3. magnets. Calibrated Circuit (Setter) Balancing Valves: Shall be GBV-Gruvlok "Circuit Balancing" Valve.6 mm perf. 2. Stainless steel tube and braid design. Grooved Suction Diffusers: Shall be Gruvlok Series 7250. F. Provide templates to ensure accurate location of anchor bolts. 2. Copper Piping: 1. Wye Strainers 758-G & 768GF: Size range 2 inches to 12 inches (305 mm).0 KPa). twin-fold basket provides 100 percent of the projected pipe area for open flow.) (1. B. Flexible Connectors: Sizes 2 inches to 12 inches (51 mm to 305 mm).9 KPa). Proportional balancing. Sizes 4 inches and larger standard with #6 mesh (1/8 inch perf. 2. Size 14 inches (356 mm) and larger: Carbon Steel Pipe ASTM A53. Tee Strainer Series 7260: Sizes 2 inches to 24 inches (51 mm to 610 mm). Baskets. Clean surfaces thoroughly prior to installation.Firestopping.6 ACCESS PANELS A. Positive shut-off. Steel Piping: 1.) (3.) With start-up #16 mesh pre-filter removable screen. Multi-turn adjustment. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. Refer to Section 15050 for piping material.) (4. 300 psig (1. Fixed or portable meters available for differential pressure measurement. 300 psig (1. Direct Flow readout. Flow measurement ports on either side of valve body. Triple Duty Combination Valves: Shall be Gruvlok "Tri-Service" (FTV-A/FTV-S) service valves. Refer to Section 15050 for piping material. Refer to Section 15050 for piping material.Combination shut-off. Blow-down and gage plug standard.9 KPa). Provide access panels as required by Section 08310 . Provide openings as necessary to permit installation of piping or any other part of work under this Section. Horizontal or vertical service usage.76 mm perf. Sizes 2-1/2 inches to 12 inches (64 mm to 305 mm). Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories section 15600 (cont.Carbon steel to ASTM A-53 body for all sizes. Rated working pressure 150 to 300 psi (1. threaded & flanged end.Stainless steel (3/16 inch perf. E. notify Architect of unsatisfactory preparation before proceeding. Pressure differential read-out ports. Refer to Section 15050 for piping material.9 EQUIPMENT ANCHOR BOLTS AND TEMPLATES A.Stainless steel Type 304-basket standard #12 mesh (1/16 inch perf. B. Submit calculations with shop drawings. D. Monel or other alloy baskets.5 PIPING A. Refer to Section 15050 for piping material. H. Valves and Fittings for HVAC Heating and Cooling Systems 1. Fabricate equipment supports not provided by equipment manufacturer from structural grade steel meeting requirements of Section 05120 Structural Steel. Services.) through 3 inches (76 mm). Differential Pressure MeterProvide CBV differential pressure meter/transducer as required.) 2. D. 3. Strainer Basket. F.Ductile iron.2 mm perf. Provide fire stopping assemblies as required by Section 07840 . Plastic Piping: 1. Throttling flow indicator is standard. Sizes 1/2 inch to 12 inches (13 mm to 305 mm). If substrate preparation is the responsibility of another installer.Access Doors and Panels.Gruvlok Models GAV-15 rated 150 psig and GAV-30 rated 300 psig.2 PREPARATION A.0 to 2.1 EXAMINATION A. Stainless Steel Piping: 1. Steel Piping: 1. Automatic Air Vents . Carbon steel grooved. Body. Strainer in-line. Aluminum Piping: 1. Do not begin installation until substrates have been properly prepared. and various mesh sizes optional. C. B. Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. non-slam silent check and full throttling. Refer to Section 15050 for piping material.com GL-7. Body.MAStEr ForMAt 3 PArt SPEcIFIcAtIon Pipes. Tamper-proof memory stop. C.Ductible 2 inches to 12 inches (51 mm to 305 mm) Malleable Iron ASTM A47 or Ductile Iron ASTM A536. 2.anvilintl. Horizontal or vertical service usage. E.8 EQUIPMENT SUPPORTS A. 2. Body. www. Basket.12 237 . For solder applications.Models FTV-S. 8. Metering ports and body/drain plugs may be interchanged for improved accessibility. 3. GBV-T (Threaded).5 PROTECTION A.com GL-7. Spool piece required is based on a minimum recommended space of 12 inches (305 mm) for pump sizes 2 inches by 2 inches (51 mm by 51 mm) to 6 inches by 6 inches (152 mm by 152 mm) and 24 inches (610 mm) for pump sizes 8 inches by 8 inches (203 mm by 203 mm) to 12 inches by 12 inches (305 x 305 mm). G. 3. GBV-T. Balancing Valves . H. 4.MAStEr ForMAt 3 PArt SPEcIFIcAtIon section 15600 (cont. Install valves with flow in the direction of the arrow on the valve body. Protect installed products until completion of project. B. Install no fittings within 2 pipe diameters downstream of valve. Install valve-bonnet assembly into body. GBV-G and GBV-A valves. Leave sufficient clearance around valve for valve removal or repair. making sure non-asbestos gasket is in place. Valves and Fittings for HVAC Heating and Cooling Systems D. as this will allow system sediment to accumulate in the ports. drain ports and hand wheel. Openings through existing concrete shall be core-drilled or saw cut. 7. This Contractor shall be responsible for establishing sizes and locations of all openings and lintels in new work and to transmit this information to the Contractor whose work is involved at such time as to avoid cutting and patching. Install valve in the direction of flow arrows on valve body.3 INSTALLATION A. 6. 6. The valve body is not designed to support the piping weight.4 VALVE INSTALLATION A. locate valves at least 5 pipe diameters downstream from any fitting and at least 10 pipe diameters downstream from a pump. 2. Provide easy access to probe metering ports (PMPs). Install valves in horizontal or vertical piping as indicated. GBV-A (Grooved-End Angle): 1.Model GBV-G (Grooved-End Straight). END OF SECTION 238 www. Provide sleeves for piping penetrating floor and masonry walls. 4. suitable for system pressure and temperatures encountered. Contractor shall inspect and take note of existing conditions along with the Owner's Representative to avoid disputes regarding the condition of existing surface before work began. solder valve body in line using 95/5 solder. 3. 3. Valve body has been designed to handle the weight of the pump on vertical in-line installations. Globe Valves . 9.anvilintl. E. 5. 2. Mount valve to flanged equipment using Gruvlok Flange Adapter or industry standard grooved coupling. F. repair or replace damaged products before Substantial Completion. Tri-Service Valves .) Pipes. Touch-up. To ensure accuracy of measurement of GBV-S. Mount valve to a spool piece on the discharge side of the pump. 3. FTV-A: 1. Do not install metering ports below the pipe (pointing down). 5.Model GBV-S (Soldered). Install in accordance with manufacturer's instructions.12 . Do not mount valve directly to pump to avoid causing undesirable noise in the system. Provide pipe supports under valve and strainer bodies. Support piping by hangers. All patching shall match adjacent surfaces. B. 2" NPS Fig. 1105R – Reducing Size Range Fig. 1166 – Coupling Size Range: 1/4" . 1104 – 45˚ Street Elbow Size Range: 1/8" . 1163 – Cap Size Range: 1/4" . 1161 – Straight Fig. 1133 – Waste Nut Sizes: 1/2" & 3/4" NPS Fig. 1121 Coupling . 1170 90˚ Street Elbow Size Range: 1/4" . 390 Countersunk Plugs Size Range: 1/2" .1" NPS Malleable Iron Threaded Fittings – Class 300 (XS/XH) Fig. 1105 – Straight Fig. 1103R: 1/2" x 3/8" thru 2" x 11/2" Fig. 1105R: 1/8" x 1/8" x 1/4" thru 4" x 4" x 3" NPS Fig. 1108 45˚ Y-Branch or Lateral Size Range: 3/8" .2" NPS Fig.3/4" NPS www.com GL-7. 1124 – Cap Size Range: 1/2" . 1101R – Reducing Elbow Size Range: 1/4" x 1/8" thru 4" x 3" NPS Fig. 1102 – 45˚ Elbow Size Range: 1/8" . 1125 – Reducer Size Range: 1/4" x 1/8" thru 6" x 4" NPS Fig. 1138 – Extension Piece Size Range: 1/2" .3" NPS Fig. 1134 – Hex Locknut Size Range: 1/8" .2" NPS Fig. 1105: 1/8" . 1164R Reducing Tee Size Range: 3/8" x 3/8" x 1/4" thru 3" x 3" x 2" NPS Fig. 1162 45˚ Elbow Size Range: 1/4" . 1106: 1/4" .6" NPS Fig.4" NPS Fig. 1106R – Reducing Street or Service Tee Size Range Fig. 1003R – Reducing 90˚ Street Elbow Size Range Fig.4" NPS Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe fittinGs Fig.PIctorIAL IndEX malleable iron fittinGs Malleable Iron Threaded Fittings – Class 150 (Standard) Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.6" NPS Fig.4" NPS Fig.2" NPS Fig.4" Fig.4" NPS Fig.12 239 . 1107 – Cross Size Range: 1/8" .3" NPS Fig. 1164 Straight Tee Size Range: 1/4" . 1103: 1/8" .2" NPS Fig. 1103 – Straight Fig. 1101 – 90˚ Elbow Size Range: 1/8" .2" NPS Malleable Iron Plain Fittings NOTE: Not to be used for pressure service.4" NPS Fig.6" NPS Fig. 1190 – Floor Flange (Ductile Iron) Size Range: 1/4" . 1161R: 3/8" x 1/4" thru 2" x 11/2" NPS Fig.2" NPS Fig.anvilintl. 1167 – Reducer Size Range: 3/8" x 1/4" thru 4" x 3" NPS Fig. 1119 Return Bends Open Pattern – Right Hand Size Range: 1/2" .4" NPS Fig.Right Hand Size Range: 1/8" . Fig. 1161R – Reducing 90˚ Elbow Size Range Fig.6" NPS Fig. 1106 – Straight Fig. 1160 45˚ Street Elbow Size Range: 1/2" . 1165 – Cross Size Range: 1/4" . 1106R: 11/4" x 1" x 11/4" Fig. 1161: 1/4" .3" NPS Fig. WSP.6" NPS Fig. 250. 832 – Dart Union Bronze to Bronze Seat Union Size Range: 3/8" . 367 Concentric Reducer Size Range: 3/4" x 1/2" thru 8" x 6" NPS Fig. 360 Straight Cross Size Range: 1/2" . Non-Shock Size Range: 1/2" .4" NPS Size Range: 4" .8" NPS 240 www.2" NPS Fig.8" NPS Fig. 551 – Class 300 Union (Male/Female) 300 Lb. 390 Countersunk Plugs Size Range: 1" .8" NPS Fig. 358 Straight Tee Size Range: 1/4" .PIctorIAL IndEX pipe fittinGs (Continued) malleable iron unions – class 150. 554 – Class 250 Union 250 Lb. 371 – 90˚ Elbow Flange & Screw Size Range: 21/2" .21/2" NPS Fig. WOG. WSP. 352 90˚ Reducing Elbow Size Range: 1/2" x 1/4" thru 6" x 5" Fig. 463 – Class 150 Union 150 Lb. 300 Lb. WSP. 380 – Solid Fig. 459 – Class 300 Union 300 Lb. WOG. 385 – Face Bushing Size Range: 3" x 2" thru 4" x 3" NPS Fig.3" NPS Fig.11 . 361 Reducing Cross Size Range 1" x 1" x 3/4" x 3/4" thru 4" x 4" x 2" x 2" NPS Fig. Non-Shock Size Range: 1/8" . 351 – 90˚ Elbow Size Range: 1/4" . 487 – Flange Union Gasket Type (Assembled with Gaskets) Fig.4" NPS Fig. 388 – Square Head Plug (Solid) Size Range: 1/2" .8" NPS Size Range: 1/2" .3" NPS cast iron fittinGs Cast Iron Threaded Fittings – Class 125 (Standard) Fig. Non-Shock Size Range: 1/8" . Non-Shock Size Range: 1/8" . 600 Lb.4" NPS Fig.6" NPS Fig. 368 Eccentric Reducer Size Range: 3/4" x 1/2" thru 6" x 4" NPS Fig. 600 Lb.com GL-6. 356R 45˚ Reducing Elbow Size: 1" x 1/2" NPS Fig. 552 – Class 300 90˚ Elbow Female Union 300 Lb. WSP Size Range: 3/8" .8" NPS Fig.4" NPS Fig. 370 – Locknut Size Range: 21/2" . 500 Lb. WSP. 356A – 221/2˚ Elbow Size Range: 3/4" . 300 Copper or Copper Alloy to Iron Fig.8" NPS Fig.4" NPS Fig. J-3300 – Class 300 All Iron Union Size Range: 1/4" .anvilintl.1" NPS Fig. WOG. 359 Reducing Tee Size Range: 1/2" x 1/2" x 1/4" thru 6" x 6" x 5" NPS Fig. 389 – Cored Bar Plugs Fig. 366 Screwed Hex Coupling Size: 1" NPS Fig. 381 – Cap Size Range: 21/2" . 387 – Square Head Plug (Cored) Size Range: 3/4" . WOG. 356 – 45˚ Elbow Size Range: 1/4" . 383 – Hex Bushing Size Range: 11/2" x 1/4" thru 10" x 8" NPS Fig.31/2" NPS Fig.2" NPS DA R T Fig. 4" NPS Fig. 701 90˚ Short Turn Elbow Size Range: 11/2" .4" NPS Fig. 723 – Reducing Tee Size: 2" x 2" x 11/2" NPS Fig.4" NPS Fig.anvilintl. 718 – 90˚ Street Elbow Sizes: 11/2" & 2" NPS Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe fittinGs (Continued) Fig. 722 – Tee Sizes: 11/2" & 2" NPS Fig.com GL-7.3" NPS Fig. 734 – 45˚ Y-Branch Sizes: 11/2" .12 241 . 708 – 111/4˚ Elbow Sizes: 11/2" & 2" NPS Fig. 744 – Tucker Connection Size Range: 11/2" . 727 – Sanitary Tee 90˚ Reducing Short Turn Sizes: 2" x 2" x 11/2" & 2" x 11/2" x 11/2" Fig. 701R – 90˚ Reducing Short Turn Elbow Sizes: 11/2" x 11/4" & 2" x 11/2" NPS Fig. 731 – Y-Branch 90˚ Reducing Long Turn Size: 2" x 2" x 11/2" NPS Fig. 736 – 45˚ Double Y-Branch Size: 11/2" NPS Fig.4" NPS Fig. 425 – Tee Size Range: 1/4" .4" NPS Fig. 752 – P-Trap Size Range: 11/2" .21/2" NPS Fig. 703 60˚ Short Turn Elbow Size: 11/2" NPS Fig. 730 – Y-Branch 90˚ Long Turn Sizes: 11/2" & 2" NPS Fig. 421 – 90˚ Elbow Size Range: 1/4" .PIctorIAL IndEX cast iron fittinGs (Continued) Cast Iron Threaded Fittings – Class 250 (Extra Heavy) Cast Iron Threaded – Safety Valve Discharge Elbow Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.3" NPS Fig.4" NPS Fig. 705 45˚ Short Turn Elbow Size Range: 11/2" . 729 – Sanitary Tee 90˚ Reducing Double Short Turn Size: 2" x 11/2" NPS Fig. 424 – 45˚ Elbow Size Range: 1/2" . 707 – 221/2˚ Elbow Sizes: 11/2" & 2" NPS Fig.4" NPS Fig. 753 – Coupling Size: 11/2" NPS Fig. 1538 – Screwed Cast Iron Size Range: 21/2" . 726 – Sanitary Tee 90˚ Short Turn Size Range: 11/2" . 706 45˚ Long Turn Elbow Size: 11/2" NPS Fig. 719 – 45˚ Street Elbow Sizes: 11/2" & 2" NPS Fig. 426 – Reducing Tee Size Range: 3/4" x 3/4" x 1/2" thru 2" x 2" x 11/2" Fig. 754 – Bath P-Trap Sizes: 11/2" & 2" NPS www. 735 – 45˚ Reducing Y-Branch Sizes: 2" x 2" x 11/2" & 4" x 4" x 3" Fig. 702A 90˚ Extra Long Turn Elbow Sizes: 11/2" & 2" NPS Fig. 702 90˚ Long Turn Elbow Size Range: 11/2" .4" NPS Cast Iron Drainage Fittings Fig. 1030 – Cast Iron Companion Flange Size Range: 2" x 81/4" thru 4" x 11" NPS 242 www.PIctorIAL IndEX pipe fittinGs (Continued) cast iron fittinGs (Continued) Cast Iron Flanged Fittings – Class 125 (Standard) Fig. 804R: 4" x 3" thru 10" x 8" Fig.anvilintl. 802 45˚ Straight Elbow Size Range: 11/2" . 1021 – Cast Iron Blind Flange Size Range: 11/2" x 61/8" thru 8" x 15" NPS Fig. 842 – Reducing Tee Sizes: 6" x 6" x 4" and 8" x 8" x 6" NPS Fig.12" NPS Fig.com GL-6. 831 90˚ Straight Elbow Size Range: 2" . 804R – Reducing Long Radius Elbow Size Range: Fig.11 . 808 – Side Outlet Elbow Size Range: 4" .12" NPS Fig. 1025 – Cast Iron Companion Flange Size Range: 11/4" x 51/4" thru 8" x 15" NPS Fig.10" NPS Fig. 804: 2" . 805 – Base Elbow Size Range: 3" .8" NPS Fig. 826 Eccentric Reducer Size Range: 3" x 2" thru 12" x 10" NPS Fig. 812 – Reducing Tee Size Range: 3" x 2" x 3" thru 12" x 12" x 10" Fig. 811 – Straight Tee Size Range: 11/2" .12" NPS Fig. 801 90˚ Straight Elbow Size Range: 11/2" . 804 – Straight Fig. 825 Concentric Reducer Size Range: 2" x 11/2" thru 12" x 10" NPS Fig. 821 – Cross Size Range: 2" . 855 Concentric Reducer Size Range: 3" x 2" thru 10" x 8" NPS Iron Flanges – Class 250 (Extra Heavy) Fig. 823 – Lateral Size Range: 2" .8" NPS Fig.8" NPS Fig. 1011 – Cast Iron Companion Flange Size Range: Fig: 1011: 3/4" x 37/8" thru 12" x 19" NPS Fig. 1010T – Cast Iron Flange Threaded Size Range: 3" x 71/2" thru 12" x 19" NPS Fig.12" NPS Fig. 1018 – Cast Iron Blind Flange Size Range: 1" x 41/4" thru 12" x 19" NPS Cast Iron Flanged Fittings – Class 250 (Extra Heavy) Fig. 803 90˚ Taper Reducing Elbow Size Range: 21/2" x 2" thru 12" x 10" NPS Fig.8" NPS Iron Flanges – Class 125 (Standard) Fig.12" NPS Fig. 1016 – Reducing Companion Flange Size Range: 1" x 5" thru 8" x 19" NPS Fig. 841 – Straight Tee Size Range: 21/2" . 6" Size Range: 1/2" .PIctorIAL IndEX pipe nipples Seamless/Welded – Black & Galvanized Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 380 Water Well Reamed and Drifted Coupling Size Range: 11/4" .2" NPS Fig. XH Sch. 40.2" NPS Flush Bushing Size Range: 1/4" x 1/8" thru 1/2" x 3 /8" NPS Cap Size Range: 1/8" . 381 #9 Drive Coupling Size Range: 11/4" . 40. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe fittinGs (Continued) Seamless Pipe Nipples Std. Sch. 337 Extra Strong (XS).3/4" NPS Solid Square Head Plug Size Range: 1/8" . Full & Half Size Range: 1/8" . 346 Standard. Sch. 336 Standard.2" www. XXH Size Range: 1/8" thru 6" Welded Pipe Nipples Std. 80. economical hose connections & repairs Combination Nipples Combination Nipples Nominal Pipe Sizes: 1/2" . Full & Half Size Range: 1/8" .com GL-7. Sch.6" NPS Fig.12" NPS Merchant Steel Bushings. Caps & Plugs Hex Bushing Size Range: 1/4" x 1/8" thru 1" x 3 /4" NPS Countersunk Plug (Square & Hex Socket) Size Range: 1/8" .2" NPS Fig.6" Size Range: 1/2" . 347 Extra Strong (XS). 379 Shallow Well Coupling Size Range: 11/4" . 348 API Line Pipe Coupling Size Range: 1/8" .12" NPS Fig.12 243 .2" Hose Menders Nominal Pipe Sizes: 1/2" . XH Sch. Right & Left Size Range: 1/2" .anvilintl.2" NPS Steel Hose Fittings For fast. Right & Left Size Range: 1/2" .6" NPS Fig. 80 Size Range: 1/8" thru 6" steel fittinGs Steel Pipe Couplings Fig. 160.2" NPS Fig.2" NPS Fig. 2141 – Half Coupling Size Range: 1/8" . 2113 – 90˚ Street Elbow Size Range: 1/8" .4" NPS Fig.4" NPS Fig. 2155 – Half Coupling Size Range: 1/8" . 2153 – Cross Size Range: 1/8" .12 .4" NPS Fig.2" NPS Fig. 2133 – 90˚ Street Elbow Size Range: 1/8" .4" NPS Fig.2" NPS Fig. 2111 – 90˚ Elbow Size Range: 1/8" . 2120 – Pipe Cap Size Range: 1/8" .3" NPS Fig.4" NPS Fig.4" NPS Fig. 2101 – 90˚ Elbow Size Range: 1/4" .11/2" NPS Fig. 2135 – Cross Size Range: 1/8" .4" NPS Fig.4" NPS Fig. 2119 – Half Coupling Size Range: 1/8" .4" NPS Fig. 2152 – Tee Size Range: 1/8" .anvilintl. 2103 – Tee Size Range: 1/4" .4" x 2" NPS Fig.4" x 2" NPS Fig.4" x 11/2" NPS Fig. 2132 – 45˚ Elbow Size Range: 1/8" . 2157 – Pipe Cap Size Range: 1/8" . 2118 – Reducing Coupling Size Range: 1/4" x 1/8". 2154 – Couplings Size Range: 1/8" .4" NPS Fig.4" NPS Class 6000 Threaded Fig.4" NPS 244 www.4" NPS Fig.4" NPS Fig. 2114 – Tee Size Range: 1/8" .2" NPS Fig. 2102 – 45˚ Elbow Size Range: 1/4" .4" NPS Fig. 2150 – 90˚ Elbow Size Range: 1/8" . 2112 – 45˚ Elbow Size Range: 1/8" . 2117 – Coupling Size Range: 1/8" . 2136 – Lateral Size Range: 1/2" .4" NPS Class 3000 Socket-Weld Fig. 2151 – 45˚ Elbow Size Range: 1/8" . 2143 – Pipe Cap Size Range: 1/8" .4" NPS Fig. 2156 – Reducing Coupling Size Range: 1/4" x 1/8".4" NPS Fig. 2104 – Cross Size Range: 1/4" .4" NPS Fig.4" NPS Fig.com GL-7. 2134 – Tee Size Range: 1/8" . 2138 – Reducing Coupling Size Range: 1/4" x 1/8".4" NPS Fig. 2116 – Lateral Size Range: 1/2" .11/2" NPS Fig.4" NPS Fig. 2131 – 90˚ Elbow Size Range: 1/8" . 2158 – Lateral Size Range: 1/2" . 2115 – Cross Size Range: 1/8" .PIctorIAL IndEX pipe fittinGs (Continued) forGed steel fittinGs Class 2000 Threaded Fig.4" NPS Fig.3" NPS Class 3000 Threaded Fig. 2137 – Coupling Size Range: 1/8" . Floor & Ceiling Plates Fig. It is used for sealing water.6" NPS www. 1/8". 3/16". 1 – with Springs Fig. 2121 – Plugs Round Head Size Range: 1/8" . acids. 7/16". 10 – with Springs Fig. steam. 1/64". miscellaneous All Purpose Asbestos Gaskets Fig. 2173 – Cross Size Range: 1/2" . & 1/4" (. 2139 – Bushings Hex Head Size Range: 1/4" x 1/8".4" NPS Fig.6. 25.4" x 2" NPS Fig. Bolts are furnished in sizes: /4". .12 245 . all oils.com GL-7.9. 2176 – Reducing Coupling Size Range: 1/2" x 1/4".2" x 1/4" NPS Socket-Weld Reducer Inserts Reducer inserts comply with MSS Standard SP-79.1.4" NPS Fig. CLASS 6000 For use with Schedule 160 Pipe Type 1 – Reducer Insert Type 2 – Reducer Insert Size Range: 3/8" x 1/4" thru 3" x 21/2" NPS Size Range: 3/8" x 1/4" thru 3" x 21/2" NPS Length of bolts are measured from under head to extreme point. 11/8". 2171 – 45˚ Elbow Size Range: 1/2" .4" NPS Fig.2" NPS Fig. 5/16". 4. 3. 29 and 32 mm) in varying lengths. 11. 1.4" NPS Fig. 2122 – Plugs Square Head Size Range: 1/8" . .5. 11/4" (6.6" NPS Size Range: 1/4" . 2170 – 90˚ Elbow Size Range: 1/2" . Available in Eight Gauges: 1/100".8. 1/16". 3/8". 9.2.4" x 11/2" NPS Fig.anvilintl.4" NPS Fig.7 and 6. 1/32". 3000. 20 – with Springs & Fig. 2140 – Bushings Flush Size Range: 1/4" x 1/8". Fig.11/2" NPS Fig. 7.11 Class 2000. 3/32". 2175 – Half Couplings Size Range: 1/2" .4" NPS Fig. 2177 – Pipe Caps Size Range: 1/2" .PIctorIAL IndEX forGed steel fittinGs (Continued) Class 6000 Socket-Weld Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.4" NPS High Pressure Plugs & Bushings Anvil High Pressure Plugs and Bushings satisfy the requiement of ASME B16. specify bolt size & length required. They enable standard socket-weld fittings to be used for making any combination of pipe line reductions quickly and economically. Socket-weld reducer inserts serve the same purpose as threaded reducing bushings with threaded fittings. 2179 (Type 2) Ring Full Face Compressed Sheet Packing is a single-formula material suitable for a wide range of temperature-pressure combinations. and 6000.6" NPS Size Range: 1/4" .4" NPS Fig. 13 – with Set Screw exposed Rivet Hinge Stamped Steel for Copper Tube Stamped Steel for Pipe Stamped Steel for Pipe Size Range: 1/4" . alkalies. 2142 – Plugs Hex Head Size Range: 1/8" .3 mm) CLASS 3000 For use with Schedule 40 & 80 Pipe Type 1 – Reducer Insert Type 2 – Reducer Insert Size Range: 3/8" x 1/4" thru 3" x 1" NPS Size Range: 3/8" x 1/4" thru 3" x 1" NPS 1 When ordering. 2 – with Set Screw Fig. 1". gases.4" NPS Fig. 2174 – Couplings Size Range: 1/2" . refigerants & hydrocarbons. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe fittinGs (Continued) Fig.4. 2178 – Lateral Size Range: 1/2" .3. 2159 (Type 1) Fig. 2172 – Tee Size Range: 1/2" . 8" Type C/R – Roll Groove Schedule 10 Size Range: 11/4" .6" Type M Type F 246 www. and Socket-Weld BUTTWELD THREADED SOCKET WELD BUTTWELD THREADED SOCKET WELD Class 3000 Threaded & Socket-Weld/Standard & XS/XH Buttweld Size Range: 1/2" . Buttweld & Socket-Weld Size Range: 1/4" .com GL-7.8" Type C – Cut Groove Standard Weight Size Range: 11/4" . readily attached 45˚ lateral outlet connection.2" NPS Universal Lateral Anvilets Class 3000 & 6000 Buttweld and Threaded Lateral Anvilets provide a strong.11/2" NPS Class 3000 Standard/XS Buttweld Size Range: 1/2" .2" NPS Class 3000 Threaded/Standard Size Range: 1/2" .12 .4" NPS 1 Standard Weight XS/XH For Oultet Sizes: 1/8" .3" NPS For Oultet Sizes: 1/8" .21/2" Eliminator Adjustable Drop Nipples Size Range: 1"x 1/2" thru 1"x 3/4" Type A – Female Thread Size Range: 1/2" .24" NPS Class 3000 For Oultet Sizes: 1/8" .2" NPS Class 6000 Threaded & Socket-Weld Size Range: 1/2" .4" NPS Class 6000 For Oultet Sizes: 1/2" .24" NPS Size Range: 1/8" .PIctorIAL IndEX pipe fittinGs (Continued) anvil universal anvilets Universal Buttweld Anvilets Full & Reducing Sizes Class 3000 & 6000 BRANCH PIPE BRANCH PIPE Universal Socket-Weld Anvilets BRANCH PIPE RUN PIPE Schedule 160 & XXS Size Range: /2" . Threaded.2" NPS Universal Threaded Anvilets Full & Reducing Sizes Class 3000 & 6000 BRANCH PIPE Universal Flat Anvilets Threaded Butt-Weld Socket-Weld RUN PIPE Class 3000 Class 3000 Threaded. Universal Elbow Anvilets Class 3000 & 6000 Butt-Weld.anvilintl.2" NPS merit® outlet fittinGs Weld-Miser™ Tee-Let® Welding Outlet Fittings Hole Templates Hand Held Hole Templates Size Range: 11/2" .4" Type B – Male Thread Standard Weight Size Range: 1" .4" NPS Class 6000 For Oultet Sizes: 1/2" . 4" EUE www.133/8" Bell Nipple Combination Couplings J-55 Size Range: 2" .3" Sub Tubing Couplings J-55 Size Range: 2" EUE x 2" Reg thru 4" EUE x 4" Reg Oil Country Casing Nipples Size Range: 41/2" .anvilintl.2" Oil Country Fittings – Tubing Swages & Casing Swages Oil Country Fittings – Adapter Nipples Large End Upset Reduced to Regular or Upset Size Range: 1" x 3/4" thru 4" x 31/2" Large End Non-Upset Reduced to Upset Size Range: 1" x 3/4" thru 4" x 3" Tubing & Casing Non EUE Ends Size Range: 1" .com GL-7.16" Chambers/Pressure Vessels Size Range: 2" .12 247 .4" Size Range: 41/2" . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe fittinGs (Continued) Concentric Swage Nipples Size Range: 1 /4" x 1/8" thru 1" x 3/4" 11/4" x 1/4" thru 8" x 6" Eccentric Swage Nipples Size Range: 1/4" x 1/8" thru 4" x 31/2" Stainless & Alloy Steel Swage Nipples Size Range: 1/4" x 1/8" thru 4" x 31/2" Carbon Steel Bull Plugs Size Range: 1/8" .20" API Casing Couplings Long Thread Size Range: 41/2" .8" Solid Refinery Plugs Black (Non-Plated) Carbon Steel Size Range: 1/8" .PIctorIAL IndEX jb smith oil country Carbon Steel – Swage Nipples Stainless Steel – Swage Nipples Carbon Steel – Bull Plugs Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.103/4" API API Bull Plug Female Size Range: 3/4" EUE .4" Special Clearance Tubing Couplings Size Range: 2" .4" Oil Country Couplings – Casing Couplings API Casing Couplings Short Thread Size Range: 41/2" . 40 Size Range: 3/4" .12" Oil Country Couplings – Tubing Couplings Oil Country Fittings – Casing Nipples Oil Country Fittings – Chamber Vessels API Tubing Couplings Size Range: 2" .8" Oil Country Fittings – Bull Plugs Tubing Bull Plugs Size Range: 3/4" EUE .4" Swage Nipples Oil Country Tubing Nipples Standard Weight Size Range: 1" .4" Tubing Nipples Extra Heavy Weight Size Range: 1" .3" EUE Casing Bull Plugs Size Range: 41/2" .85/8" Adapter Nipples Seamless Sch. 2" NPS THREADED SOCKET WELD 248 www.500 psi test Size: 2" 2.000 psi test Size Range: 1" .000 psi test Size Range: 1" thru 4" Fig.000 psi test Size Range: 1" .000 psi cwp . 202 Blanking Cap Only with O-Ring Size: 4" 3. 160 10. 602 Buttweld Ends .000 psi cwp . 211 Threaded Ends Insulating Union 2. 602 Threaded Ends Fig.22.Sch.000 psi cwp .500 psi test Size Range: 1" .000 psi test Size Range: 1".000 psi test Sizes: 11/2" & 2" Fig.3" Fig. 2128 – Socket-Weld Size Range: 1/4" .000 psi cwp .000 psi cwp .000 psi cwp .000 psi cwp .6" Fig. 200 Threaded Ends 2. 1502 Buttweld Ends .000 psi test Size Range: 2" . 40 Fig.000 psi cwp .Sch.3" NPS CLASS 6000 Fig.4" Fig.Lug Union 2. 607 Threaded Ends Well Service Union 2.000 psi cwp .000 psi cwp .000 psi cwp .15. 400 Buttweld Ends .4" 10.3. CLASS 3000 Fig.500 psi test Size Range: 2" .4" Fig.3" Fig.000 psi cwp .12 . 160 15.000 psi cwp .22.500 psi test Size Range: 1" .3.Lug Union 1. 100 Threaded Ends 1. 206 Threaded Ends 2.500 psi test Sizes: 2" & 3" Fig.3.3.15.Sch.Sch. 1002 Threaded Ends 10.6" Fig.4. 40 2.Sch.000 psi test Size Range: 2" .Sch. 301 Steam Service Union Fig.500 psi test Sizes: 2" & 3" Fig.000 psi test Sizes: 1" & 2" 2.com GL-7.000 psi test Size: 2" 6.000 psi test Size Range: 2" thru 4" Fig.1.4.000 psi test Size Range: 1" .6" Fig. XXH 15.3. 3L S1A Tri-Lug High Speed Union 3.2" Fig. 300 Flat-Face Union 3.22. 2127 – Threaded Fig. 80 6.000 psi test Size Range: 1" . 1502 Threaded Ends 15. 2125 – Threaded Fig. 100C Threaded Ends .000 psi test Size Range: 2" .9.15. XXH Fig.000 psi cwp .4.8" Fig.000 psi test Size Range: 1" . 400 Threaded Ends 4. 1002 Buttweld Ends .3.500 psi test Size Range: 1" .9.2" Forged Steel Unions Manufactured to MSS Standard Practice SP83 (Class 6000 by method of MSS SP83). 600 Threaded Ends 6.1.PIctorIAL IndEX pipe fittinGs (Continued) catawissa unions Wing Unions Fig. 200 Buttweld Ends . 200C Threaded Ends .000 psi cwp .000 psi cwp . S1A High Speed Union Fig.000 psi test Size Range: 2" .anvilintl. 1002 Buttweld Ends . 80 4.6.000 psi cwp .3.4" Fig.500 psi test Sizes: 2" & 3" Fig.000 psi cwp . 2126 – Socket-Weld Size Range: 1/4" .6" Fig.000 psi test Size Range: 1" thru 4" Fig.9.000 psi cwp .000 psi cwp .3.000 psi cwp .Sch.000 psi cwp . 1502 Buttweld Ends .000 psi cwp .000 psi cwp .Sch.6.4" Fig. 206 Buttweld Ends . 261 Extension Pipe or Riser Clamp Size Range: /4" . 295H Heavy Duty Double Bolt Pipe Clamp Size Range: 6" . 212 Medium Pipe Clamp Size Range: 1/2" .12" Fig.8" Fig.16" Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe hanGers Copper Tubing Hangers Steel Pipe Clamps Clevis Fig. 69F Adjustable Swivel Ring Felt Lined Size Range: 1/2" .24" pipe www. 65 Light Duty Adjustable Clevis Size Range: 3/8" .4" Fig.24" Pipe Shields & Saddles Fig. 600 & Fig.6" Fig. 594 Socket Clamp Fig. 67F Copper Tube Felt Lined Hanger Size Range: 1/2" .6" Fig. CT-138R Extensions Split Tubing Clamp Size Range: 1/2" .2" Fig. 160 to 166A Fig.24" Fig. 295A Alloy Double Bolt Pipe Clamp Size Range: 11/2" .8" Fig. 187 Two Hole 90˚ Side Mount Strap Size Range: 3/4" . 260 Adjustable Clevis Hanger Size Range: 1/2" .16" Fig. CT-65 Light Weight Adjustable Clevis Size Range: 1/2" . 188 Two Hole Stand Off Strap Size Range: 3/4" . 40 Riser Clamp Standard Size Range: 2" . 300 Adjustable Clevis for Insulated Lines Size Range: 3/4" .4" Fig.4" 1 Fig. 590 Adjustable Clevis for Ductile or Cast Iron Size Range: 3" . 67 Pipe or Conduit Hanger Size Range: 1/2" . 103 Offset Pipe Clamp Size Range: 3/4" . 168 Rib-Lok Shield Size Range: 1/2" thru 8" pipe or copper tube with up to 2" thick insulation.com GL-7.24" Fig. 260 ISS Clevis Hanger with Insulation Saddle System Size Range: 2" . 246 Heavy Duty Alloy Steel Pipe Clamp Size Range: 10" . 186 Two Hole Pipe Strap Size Range: 3/4" .2" Fig.6" Fig.30" Fig.24" 3 Fig.2" Fig.4" Fig. 295 Double Bolt Pipe Clamp Size Range: 3/4" . 595 & Fig. 100 Extended Pipe Clamp Size Range: 1/2" .4" Fig. 224 Alloy Steel Pipe Clamp Size Range: 4" . 185 One Hole Pipe Strap Size Range: 3/4" .12" Fig.24" For Ductile Iron or Cast Iron Pipe & Socket Clamp Washer Size Range: 4" . 216 Heavy Pipe Clamp Size Range: 3" .36" Socket Clamps Fig. CT-69 Adjustable Swivel Ring Size Range: /2" .24" pipe Fig.2" Fig. 212FP Earthquake Bracing Clamp Size Range: 21/2" .42" Fig.anvilintl.PIctorIAL IndEX Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. 167 Insulation Protection Shield Size Range: 1/2" thru 24" pipe with up to 2" thick insulation.36" Fig. CT-128R Rod Threaded Ceiling Flange Sizes: 3/8" thru 1/2" Fig. 599 Socket Clamp For Ductile Iron or Cast Iron Pipe & Socket Clamp Washer Size Range: 3" . CT-121 Copper Tubing Riser Clamp Size Range: 1/2" .12 249 . CT-255 Copper Tubing Alignment Guide Size Range: 1" . Fig.30" Fig. CPVC Pipe Hangers Fig.2" Pipe Covering Protection Saddle Size Range: 3/4" thru 36" Fig. 137C Plastic Coated U-Bolt Size Range: 1/2" .com GL-7. 112 & 113 Brace Fitting Compete Sizes: 1" and 11/4" 250 www. 190 Off-Set Eye Socket Size: 3/8" Fig. 127 Plastic Ceiling Plate Sizes: 3/8" and 1/2" Fig. 227 Top Beam Clamp Fig. 94 Wide Throat Top Beam C-Clamp Sizes: 5/8" and 3/4" Fig.33/4" Ceiling Plates & Flanges Fig. 134 Heavy Duty Beam Clamp Size Range: 4" .anvilintl. 66 Welded Beam Attachment Size Range: 3/8" . 202 Iron Side Beam Bracket Size Range: /8" . 55: 1/2" .33/4" Fig.3/4" Fig. 195 Medium Welded Steel Bracket Fig.2" Fig. 133 Standard Duty Beam Clamp Size Range: 4" .5/8" Fig.10" Structural Attachments Fig. 199 Heavy Welded Steel Bracket Fig. 14 Adjustable Side Beam Clamp Sizes: 3/8" .1/2" Fig.36" Fig.3/4" Fig. 95 C-Clamp with Lock Nut Sizes: 3/8" and 1/2" Fig. 292 & 292L Beam Clamp with Weldless Eye Nut Fig. 46 Universal Trapeze Assembly Fig.3/4" Fig. 50 Equal Leg Angle for Trapeze Assembly Brackets U-Bolts Fig. 218 Malleable Beam Clamp without Extension Piece Fig. 89X Retaining Clip Size Range: 3/8" . 189 Staight Eye Socket Size: 3/8" Fig. 92 Universal C-Type Clamp Standard Throat Sizes: 3/8" and 1/2" Fig. 86 & 88 C-Clamp with Set Screw and Lock Nut Size Range: 3/8" . 55L: 1/2" .PIctorIAL IndEX pipe hanGers (Continued) Beam Clamps Fig. 45 Channel Assembly Fig. 89 Retaining Clip Size Range: 3/8" .8" Fig. 60 Steel Washer Plate Size Range: 3/8" . 153 Pipe Hanger Flange Size Range: 3/8" . 207 Threaded Steel Side Beam Bracket Sizes: /8" and /2" 3 1 Fig. 194 Light Welded Steel Bracket Fig.12" Fig. 93 Universal C-Type Clamp Wide Throat Sizes: 3/8" and 1/2" Fig. 120 Light Weight U-Bolt Size Range: 1/2" .8" Fig./8" 3 5 Steel Side Beam Bracket Size Range: /8" ./8" 3 5 Fig.21/4" Fig. 228 Universal Forged Steel Beam Clamp Fig.12 . 54 Two Hole Welding Beam Lug Size Range: 1/2" . 137 & 137S Standard U-Bolt Size Range: 1/2" . 55L Structural Welding Lug Size Range: Fig. Ceiling Flange Sizes: 3/8" & 1/2" Fig.75/8" Fig. 217 Adjustable Side Beam Clamp Size Range: 3" . 128R Rod Threaded. 395 Cast Iron Ceiling Plate Size Range: 1/2" . 206 Fig.12" Trapeze Fig. 55 & Fig.31/2" Fig. 1 /4" 3 1 Fig. 62 Type A.1" Fig. 138R Extension Split Pipe Clamp Size Range: 3/8" .7/8" Fig.com GL-7. 278X Linked Eye Rods Welded Size Range: 3/8" .21/2" Fig.7/8" Fig. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories pipe hanGers (Continued) Concrete Inserts & Attachments Hanger Rods & Accessories Fig. Split Ring Type Size Range: 3/8" .3/4" Fig.12 251 . 278 & 278L Eye Rod Welded Size Range: 3/8" . Fig.13/4" Pipe Supports Fig. 69 Adjustable Swivel Ring Size Range: 1/2" .42" Fig. 290 & 290L Weldless Eye Nut Size Range: 3/8" . 136: Fig.21/2" Fig.8" www. B & C Pipe Stanchion Size Range: 2" .5/8" Fig.4" Fig. 233 Turnbuckle Size Range: 11/4" . 49 Concrete Clevis Plate Size Range: 3/8" . 282 Universal Concrete Insert Size Range: 3/8" .PIctorIAL IndEX Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.21/2" Fig. 285 Light Weight Concrete Insert Size Range: 1/4" .2" 1 Fig. 157 Extension Piece Size Range: 3/8" . 135: 3/8" . 284 Metal Deck Hanger Size Range: 3/8" .12" Fig. 110R Socket.21/2" Fig.7/8" Fig. 104 Adjustable Swivel Ring. 135. 47 Concrete Single Lug Plate Size Range: /2" . 114 Turnbuckle Adjuster Size Range: 1/4" .36" Fig. 135R: 3/8" x 1/4" .7/8" x 3/4" Fig.11/2" Fig.anvilintl. Other even foot lengths can be furnished to order.21/2" Fig. Rod Threaded Size Range: 1/4" .5" Fig. 140 & 253 Machine Threaded Rods Threaded Both Ends Sizes: 3/8" .1" Fig. 259 Adjustable Pipe Saddle Support Size Range: 4" .1" Fig.18" Fig.8" Fig.5" Fig. 299 Forged Steel Clevis Size Range: 3/8" . ten & twelve foot lengths. 148 Rod with Eye End Size Range: 23/4" . 108 Split Pipe Ring Size Range: 3/8" . B & C Pipe Stanchion Size Range: 21/2" . 258 Stanchion Pipe Saddle Support Size Range: 4" .8" Fig. 136R: Fig. 281 Wedge Type Concrete Insert Size Range: 1/4" .36" Fig.36" Fig. 191 Adjustable Pipe Saddle with U-Bolt Size Range: 2" . 142 Coach Screw Rods Machine Threaded on Opposite End Sizes: 3/8" and 1/2" Fig.5" Fig.3/4" Fig. 286 Iron Cross Design Size Range: 3/4" .7/8" Fig. 63 Type A.36" Fig. 248 & 248L Eye Rod Not Welded Size Range: 3/8" . 265 Adjustable Pipe Saddle Support Size Range: 4" .3" Fig. 230 Turnbuckle Size Range: 3/8" .7/8" Fig. 291 Clevis Pin with Cotters Size Range: 1/2" . 135E: 1/4" . 248X Linked Eye Rods Size Range: 3/8" .11/2" Stocked in six. 136 & 136R Straight Rod Coupling Size Range: 1/4" . 264 Adjustable Pipe Saddle Support Size Range: 21/2" . 135E & 135R Rod Coupling Size Range: Fig. 152 Screw Concrete Insert Size Range: 3/8" .4" Pipe Rings Fig. 52 Concrete Rod Attachment Plate Size Range: /8" . 192 Adjustable Pipe Saddle Support Size Range: 2" .21/2" Fig. 146 Continuous Thread Sizes: 1/4" .12" Fig. 274.com GL-7. 274P & 275 Adjustable Pipe Roll Stand Size Range: 2" .anvilintl.4" Fig. 82 & C-82 Short Spring Fig.24" Pipe and Insulation Thickness of 1" thru 4" Fig.4" Fig.800 Pounds & maximum forces from 200 to 7. B-268 & C-268 Standard Spring Triple Spring.30" pipe Fig. 302 & 303 Sway Brace Size Range: Pre Loads from 50 to 1. 170 Horizontal Traveler Fig.24" Fig. 439 & 439A Structural "H" Slide Assembly Size Range: 6" .42" Fig. C-640 Sway Strut Assembly Fig.200 Pounds. 222 & C-222 Mini-Sway Strut Assembly Pipe Rolls Spring Hangers Fig. 312 Tapered Pin Size Range: 3/8" . 432 Special Clamp Size Range: 2" . 436 & 436A Fabricated Tee Slide Assembly Size Range: All Sizes within Maximum Load Rating Model R 80-V Vertical Constant Support Model R 81-H Horizontal Constant Support Fig. 3306 & 3307 Hydraulic Shock & Sway Suppressor (Snubber) Size Range: Six Standard Sizes with Load Ratings from 350 to 50.30" Fig.700 (LBS). 277 Pipe Roll & Base Plate Size Range: 2" . 640.6" pipe Fig.000 (LBS). 257 & 257A Structural Tee Slide Assembly Size Range: All Sizes within Maximum Load Rating Fig. 80-V & 81-H constant supports are made in nine different frame sizes & 110 spring sizes to accomodate travels from 11/2" to 20" & loads from 27 lbs to 87. 262 Strap Short Size Range: 1/2" . 271 Pipe Roll Stand Size Range: 2" . 298. Horizontal Traveler & Sway Brace Snubbers Fig.24" and Insulation Thickness of 1" thru 4" (Also available in copper tube sizes) Fig.6" pipe Fig. 181 Adjustable Steel Yoke Pipe Roll Size Range: 21/2" .30" Size Range: Anvil Model R constant support hangers are made in two basic designs.36" Fig. Fig.500 lbs. 255 Pipe Alignment Guide Size Range: 1" . 211.30" Fig. Fig. Size Range: Available in Four Sizes to Take Loads to 20. 126 One-Hole Clamp Size Range: 3/8" . 178 Spring Cushion Hanger Fig.42" Fig. 297. 243 Pipe Strap Size Range: 1/2" .21/2" Fig.PIctorIAL IndEX pipe hanGers (Continued) Straps Sway Strut Assembly Fig.000 (LBS). 256 Pipe Alignment Guide Size Range: 1" .12 .24" Fig. Quadruple Spring-CR Pipe Guides & Slides Constant Supports Fig. C-211. 201 & C-201 Hydraulic Shock & Sway Suppresor (Snubber) Size Range: Nine standard sizes with load ratings from 350 (LBS) to 120. 296. Triple Spring-CR Fig. 244 Pipe Strap Size Range: 1/2" . 177 Adjustable Pipe Roll Support Size Range: 1" . 301. 200 & C-200 / Fig. 212 Medium Pipe Clamp Size Range: 2" . 252 www. 175 Roller Chair Size Range: 2" . All sizes provide for 12" of Horizontal Travel. 98 & C-98 Double Spring Quadruple Spring.24" Fig. 171 Single Pipe Roll Size Range: 1" . 772 Adjustable Steel Beam Attachment Size Range: Flange Widths 4" thru 15" Fig.8" Service Pipe Fig. 778 Bar Joist and Beam Attachment (WF) Size Range: Flange Thickness 1/8" thru 3/4" Fig.12 253 . 776 Brace Clamp Size Range: 21/2" . Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories PIPE HANGERS • SWAY BRACE .8" Service Pipe Fig.anvilintl.SEISMIC Pipe Brace Clamps Structural Attachments Fig. 773 Surge Restrainer Size Range: 3/4" .8" Service Pipe Restraints Sway Brace Attachment Fig. 771 Sway Brace Swivel Attachment Size Range: 1" and 11/4" Brace Pipe www.PIctorIAL IndEX Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.com GL-7.2" Swivel Ring Hanger Fig.6" Service Pipe Fig. 775 Lateral/Longitudinal Brace Clamp Size Range: 21/2" . 770 Q Brace Clamp Size Range: 1" . 779 Multi-Connector Adapter Size Range: 1" . 777 Swivel Joint Connector Rod Tap Size Range: 3/8" Rod Diameter Fig. Size: 15/8" x 15/8" x 14 GA. Size: 15/8" x 31/4" x 12 GA. Size: 15/8" x 31/4" x 12 GA. /8" Knock Outs on 6" Centers. Size: 15/8" x 31/4" x 14 GA. 9 /16" Holes on 17/8" Centers. Two Pcs. Size: 15/8" x 31/4" x 12 GA. AS 200 Welded Side-to-Opposite Side. 9 /16" Holes on 17/8" Centers. Size: 15/8" x 27/16" x 12 GA. /8" Knock Outs on 6" Centers. /16" x 11/8" Elongated Holes on 2" Centers. as 200btb Welded Channel as 200eh btb Welded Channel as 200sts Welded Channel as 200bts Welded Channel as 200stsr Welded Channel Size: 15/8" x 31/4" x 12 GA. Size: 15/8" x 15/8" x 14 GA.com GL-6.anvilintl. /8" Knock Outs on 6" Centers. 9 /16" Holes on 17/8" Centers. 7 Size: 15/8" x 27/16" x 12 GA. as 210 Channel Size: 15/8" x 15/8" x 14 GA. Size: 15/8" x 15/8" x 12 GA. /32" x 3" Slots on 4" Centers. /16" x 11/8" Elongated Holes on 2" Centers. 7 Size: 15/8" x 13/8" x 12 GA. AS 200 Welded Side-to-Back.11 . Size: 15/8" x 31/4" x 12 GA. 13 /32" x 3" Slots on 4" Centers. 7 /8" Knock Outs on 6" Centers. Two Pcs. 13 /32" x 3" Slots on 4" Centers. Channel with Elongated Holes 9 as 210eh as 210ko Channel with Knock Outs as 210h Channel with Holes Channel with Long Slots as 210s as 210btb Welded Channel Size: 15/8" x 15/8" x 14 GA. 7 Size: 1 /8" x 3 /4" x 12 GA. Size: 15/8" x 15/8" x 12 GA. Two Pcs. Channel with Elongated Holes 9 as 100eh 5 1 as 100ko Channel with Knock Outs 5 1 Channel with Holes as 100h Channel with Long Slots as 100s as 100btb Welded Channel Size: 1 /8" x 3 /4" x 12 GA. 254 www. AS 100 Welded Back-to-Back. AS 200 Welded Back-to-Back. Size: 15/8" x 15/8" x 12 GA. /16" x 11/8" Elongated Holes on 2" Centers. /16" x 11/8" Elongated Holes on 2" Centers. AS 200 Welded Back-to-Back. Size: 15/8" x 13/8" x 12 GA. /16" Holes on all three sides are on 17/8" Centers. Size: 15/8" x 27/16" x 12 GA. Channel with Holes on all Three Sides 9 as 200h3 Size: 15/8" x 15/8" x 12 GA. Two Pcs. 13 /32" x 3" Slots on 4" Centers Size: 15/8" x 61/2" x 12 GA.PIctorIAL IndEX Channels as 100 Channel Size: 15/8" x 31/4" x 12 GA. as 300 Channel Size: 15/8" x 13/8" x 12 GA. 9 /16" x 11/8" Elongated Holes on 2" Centers. Channel with Elongated Holes 9 as 150eh as 150ko Channel with Knock Outs as 150h Channel with Holes Channel with Long Slots 13 as 150s as 150btb Welded Channel Size: 15/8" x 27/16" x 12 GA. /32" x 3" Slots on 4" Centers. /16" Holes on 17/8" Centers. 7 Size: 15/8" x 15/8" x 14 GA. Two Pcs. AS 200EH Welded Back-to-Back. 9 /16" Holes on 17/8" Centers. Size: 15/8" x 31/4" x 12 GA. Two Pcs. AS 150 Welded Back-to-Back. AS 210 Welded Back-to-Back. Size: 15/8" x 31/4" x 12 GA. Size: 15/8" x 13/8" x 12 GA. as 150 Channel Size: 15/8" x 27/16" x 12 GA. Size: 15/8" x 23/4" x 12 GA. Two Pcs. AS 300 Welded Back-to-Back. Channel with Elongated Holes as 200eh as 200ko Channel with Knock Outs as 200h Channel with Holes 9 Channel with Long Slots 13 as 200s Size: 15/8" x 15/8" x 12 GA. Two Pcs. Channel with Elongated Holes 9 as 300eh as 300ko Channel with Knock Outs Channel with Holes as 300h Channel with Long Slots as 300s as 300btb Welded Channel Size: 15/8" x 13/8" x 12 GA. as 200 Channel Size: 15/8" x 15/8" x 12 GA. Size: 15/8" x 47/8" x 12 GA. /8" Knock Outs on 6" Centers. Two Pcs. 9 /16" x 11/8" Elongated Holes on 2" Centers. Size: 15/8" x 15/8" x 12 GA. Size: 15/8" x 1" x 12 GA. Size: 15/8" x 13/16" x 14 GA.PIctorIAL IndEX Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs.Clamping Nut without Spring as ss .Top Grip Nut with Spring on Top Use with all 15/8" wide channel Stud Nut with RS Spring as 517 www. 9 /16" Holes on 17/8" Centers. as 560 Channel Size: 15/8" x 13/16" x 16 GA. AS 400 Welded Back-to-Back. 135 Continuous Threaded Rod fig. 9 /16" Holes on 17/8" Centers. 13 /32" x 3" Slots on 4" Centers.Clamping Nut with Long Spring Use with AS 200.com GL-6. Channel with Elongated Holes 9 as 500eh Channel with Holes as 500h Channel with Long Slots as 500s as 500btb Welded Channel Size: 15/8" x 13/16" x 14 GA. Two Pcs. AS 210 and AS 300 Use with AS 100 & AS 150 Slotted Hex Head Machine Screw as 6075 as 6108 Square Nut Seismic Rod Stiffener as 3500 Hex Head Cap Screw as 6024 as tG . For All 15/8" Width Channels. as 520 Channel Size: 15/8" x 13/16" x 12 GA. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories anvil-strut™ (Continued) Channels (continued) as 400 Channel Size: 15/8" x 1" x 12 GA. 13 /32" x 3" Slots on 4" Centers. Two Pcs. Two Pcs. as 500 Channel Size: 15/8" x 13/16" x 14 GA. 9 /16" Holes on 17/8" Centers. Size: 15/8" x 2" x 12 GA. 146 as ns . Channel with Elongated Holes 9 as 400eh as 400ko Channel with Knock Outs Channel with Holes as 400h Channel with Long Slots as 400s as 400btb Welded Channel Size: 15/8" x 1" x 12 GA.Clamping Nut with Regular Spring as ls . 7 Size: 15/8" x 1" x 12 GA. /16" x 11/8" Elongated Holes on 2" Centers. 13 /32" x 3" Slots on 4" Centers. Size: 15/8" x 13/16" x 14 GA. Channel with Elongated Holes 9 as 560eh Metal Raceway Closure Strip as 707 Metal Painted Closure Strip as 707p Size: 15/8" x 13/16" x 16 GA. Channel with Elongated Holes 9 as 520eh Channel with Holes as 520h Channel with Long Slots as 520s as 520btb Welded Channel Size: 15/8" x 13/16" x 12 GA. (10' Length) Channel Hardware Channel Nuts Double Conveyer Adjusting Nut as 3281 Hexagon Nut as 83 Rod Coupling fig. Size: 15/8" x 1" x 12 GA. /16" x 11/8" Elongated Holes on 2" Centers.anvilintl.11 255 . Size: 15/8" x 13/16" x 12 GA. /8" Knock Outs on 6" Centers. /16" x 11/8" Elongated Holes on 2" Centers. AS 500 Welded Back-to-Back. Size: 15/8" x 13/16" x 12 GA. Size: 15/8" x 15/8" x 14 GA. AS 520 Welded Back-to-Back. (10' Length) For All 15/8" Width Channels.Clamping Nut with Short Spring Use with all 15/8" wide channel Use with AS 400 and AS 500 Use with all 15/8" wide channel Flat Washer as 209 Linked Eyelet with Stud as 203 Lock Washer as 211 Fender Washer as 230 as rs . /16" x 11/8" Elongated Holes on 2" Centers. 86 fig. Use with AS 500 & AS 520. Beam Clamp as 2651 "U" Bolt Beam Clamp with Hook as 2656 Plates Double "U" Bolt Beam Clamp as 2657 Splice Clevis Two Hole Splice Plate as 601 Three Hole Splice Plate as 602 Three Hole Swivel Plate as 617 Two Hole Connecting Plate as 620 as 631 Two Hole Splice Clevis as 644 Two Hole Splice Clevis Use with AS 200 & AS 210.1/2" Size Range: 5/8" . Four Hole Corner Plate as 719 Four Hole Splice Plate as 888 Square Washer as 619 Square Washer with Channel Guide as 2504 256 www.Use with AS 200 and AS 210.anvilintl.11 . Use with AS 500 & AS 520. Heavy Duty Suspension Rod Beam Clamp as 858 Wide Throat Heavy Duty Beam Clamp as 865 Safety Anchor Strap AS 871 sold separately.Use with AS 500. Safety Anchor Strap (For Heavy Duty Beam Clamps) as 871 as 907 "I" Beam Clamp as 998 "I" Beam Clamp as 2623 Swivel Adapter Includes Cup Point Set Screw. Safety Anchor Strap AS 871 sold separately. 95 Light Duty Beam Clamp as 135x Size Range: 3/8" . Cross Plate as 712 as 714 "T" Plate "T" Plate . as 616 Four Hole Splice Clevis as 646 Four Hole Splice Clevis Use with AS 200 & AS 210.3/4" Beam Clamp as 684 Beam Clamp as 685 Beam Clamp as 686 as 855 Angular "C" Beam Clamp AS 855 1 . Use with AS 2622 Beam Clamp.PIctorIAL IndEX anvil-strut™ (Continued) Clamps & Accessories Rod or Insulator Support as 85 Clamp with Lock Nut fig.com GL-6. AS 855 2 . 93 Top Beam "C" Clamp fig. Use with AS 500. 94 Top Beam "C" Clamp Clamp with Lock Nut fig.90˚ as 715 Flat Angle Plate as 718 as 629 Three Hole Splice Clevis as 645 Three Hole Splice Clevis Use with AS 200 & AS 210. Includes Set Screw. 12 257 . AS 200BTB & AS 210BTB. as 2648 "U" Support as 687 Slotted "U" Support as 721 "U" Support Three Hole "U" Support as 678 as 733 Six Hole "U" Support Eight Hole "U" Support as 735 Use with AS 150. Use with AS 400. Use with AS 100. Use with AS 200 & AS 210. as 764 Slotted Adjustment Corner Angle Two Hole Angle with Impressions on Both Legs as 806 One Hole Angle as 921 Corner Angle as 2144 Two Hole Adjustment Angle as 2520 Slotted 90˚ Angle as 2545 Three Hole Corner Angle as 605 Three Hole Corner Angle as 606 Three Hole Corner Angle as 745 Two Hole Slotted 90˚ Corner Connector as 3049 Four Hole Corner Angle as 607 Four Hole Open Angle Connector as 781 Four Hole Closed Angle Connector as 793 Four Hole Joint Corner Connector as 614 Four Hole Shelf Joint Angle Connector as 615 Adjustable Double Slotted Corner Connector as 689 Four Hole Corner Joint Connector as 748 Five Hole Corner Connector as 927 Flat Corner Connector as 744 Four Hole Corner Connector as 750 www. AS 210 and AS 500BTB. Use with AS 150. Use with AS 100. Use with AS 150BTB. "Z" Supports Two Hole Offset "Z" Support as 609 as 611 "Z" Support as 612 "Z" Support as 711 "Z" Support as 756 "Z" Support as 928 "Z" Support as 2601 "Z" Support Use with AS 200.anvilintl. Use with AS 500 & AS 520. AS 210 and AS 500BTB. Use with AS 500 & AS 520. Use with AS 100. AS 200BTB and AS 210BTB. Use with AS 300. Use with AS 200BTB. AS 200BTB and AS 210BTB.PIctorIAL IndEX Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. Angle Fittings and Connectors Two Hole End Angle as 603 Two Hole Corner Angle as 604 Two Hole Closed Angle Connector as 624 Two Hole Open Angle Connector as 633 as 763.com GL-7. Use with AS 400. Use with AS 300. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories anvil-strut™ (Continued) "U" Supports as 613 "U" Support as 679 "U" Support as 710 "U" Support as 929 "U" Support as 978 "U" Support "U" Connector as 2119 Use with AS 200. Use with AS 200 & AS 210. Post Bases Double Column Post Base as 2064 Single Column Post Base as 3013 as 3013 sQ Single Column Post Base as 3013 fl Single Column Post Base as 3025 Post Base as 3025 fl Post Base Use with AS 100. Use with AS 200 and AS 210 Channel. Use with all 31/4" Channels. Use with AS 200 and AS 210 Channel.com GL-7. Double Column Post Base as 3029 as 3033 Post Base as 3040 Post Base as 3064 Double Column Post Base as 3064 sQ Double Column Post Base Adjustable Base as 9400 Use with all 31/4" Channels. Use with AS 200 and AS 210 Channel.anvilintl. Use with all 31/4" Channels. AS 200STS. AS 200BTS and AS 200STR Channel Use with AS 200 and AS 210 Channel. 258 www. Use with AS 200 and AS 210 Channel. Use with AS 200 and AS 210 Channel.12 . AS 200BTB. Use with AS 200 and AS 210 Channel.PIctorIAL IndEX anvil-strut™ (Continued) Angle Fittings and Connectors (continued) Flat Corner Connector as 2190 Symmetrical Four Hole Connector as 747 Flat Connector as 854 Symmetrical Three Hole Joint Connector as 925 Cross Connector as 2112 Four Hole Double Corner Connector as 665 RH & LH Angle Plate Connector as 720 as 922 rh & lh Two Hole Single Corner Angle Connector Five Hole Two Angle Connector as 923 as 2128 rh & lh Six Hole Corner Connector Six Hole Double Corner Connector as 666 Eight Hole Double Angle Connector as 821 Eight Hole Double Corner Connector as 667 Ten Hole Two Angle Clevis Connector as 913 Six Hole Three Angle Connector as 668 Twelve Hole Three Angle Clevis Connector as 669 as 2560 & as 2561 Conduit Connector Fitting Assembly Offset Connector as 3060 Two Hole Hinge Connector as 9402 Three Hole Hinge Connector as 9403 Four Hole Hinge Connector as 9404 Cup Support for Standard Single Strut as 677 Inside Clevis as 993 as 2401 thru as 2403 Ladder Rung Use with AS 200 and AS 210. Data Services Coatings & Assembly Groovers Steel Method Fittings Couplings Fittings Nipples System Pressure Accessories anvil-strut™ (Continued) Brackets Reversible Strut Bracket as 651 as 661 t1 Strut Bracket (Slot Up) as 661 t2 Strut Bracket (Slot Down) Single Channel Bracket Support as 708 Shelf Bracket as 732 Double Channel Bracket as 809 Use with AS 200.com GL-7. as 825 rh/lh Pipe Axle Support 6" thru 30" Shelf Bracket as 838 rh/lh Strut Brace as 926 as 2404 thru as 2408 Wall Ladder Bracket 45˚ Stair Tread Support as 2421 341/2˚ Stair Tread Support as 2422 Double Channel Bracket Support as 3164 Universal Angle Bracket as 3373 Spacer Clevis as 2627 as 2654 & as 2654a Column Attachment Use with all 31/4" Channels. Offered in Pre-Assembled only. Offered in Pre-Assembled only. 137 Conduit Clamp as 270 One Hole Clamp for O. Trolleys & Accessories Two Wheel Trolley as 2521 Four Wheel Trolley as 2522 as 2528 Trolley Beam Standard Support as 2528-1 Trolley Beam Joint Support Use with AS 200 Channel. Use with AS 200 and AS 210 Channel. Use with AS 200 Channel. 67 Swivel Ring Hanger fig. AS 210 and AS 500BTB.12 259 .anvilintl.D. Tubing as 1450 as 3101 thru as 3115 One Piece Cable and Conduit Clamp Hold Down Clamp as 3126 as 1000 EMT Conduit Clamps as 1100 Rigid Steel Conduit Clamps O. 69 "U" Bolt with Nuts Long Tangent fig. Use with AS 200 and AS 210 Channel.D. Tubing Clamp as 1200 Universal Pipe Clamp as 1300 Offered in Pre-Assembled only.PIctorIAL IndEX Roll Stainless Sock-It® HDPE Plain-End DI-LOK® CTS Copper High Pictorial Master Format Technical Design Special Installation Valves & Fittings Outlets Couplings Introduction Index 3 Part Specs. www. Offered in Pre-Assembled only. Pipe and Conduit Supports Right Angle Pipe or Conduit Clamp as 51 Pipe or Conduit Hanger fig. 260 www. Use with AS 500 Channel. AS 6153 1 – Use with AS 100. 152 Light Weight Concrete Insert fig. AS 300. Use with AS 100. AS 150. End Cap with Knockout as 2511 Safety End Cap as 6153 AS 2511 1 – Use with AS 100. 285 as 349 Continuous Concrete Insert as 449 Continuous Concrete Insert with or without Closure Strip and End Cap Installed. Plastic Closure Strip as 6151 End Caps Type "B" End Cap Anchor as 653 Type "B" End Cap Anchor as 654 as 655 & as 656 Type "A" End Cap as 901 & as 902 Type "A" End Cap Type "A" End Cap as 930 Type "A" End Cap as 2580 Use with AS 349 Insert.PIctorIAL IndEX anvil-strut™ (Continued) Pipe and Conduit Supports (continued) (6" to 18" Pipe) Double Roller Pipe Support as 815 (1" to 8" Pipe) Pipe Roller Support as 1901 (1" to 8" Pipe) Pipe Roller Support as 1902 (2" to 14" Pipe) Pipe Roller Support as 1911 as 2631 Swing Gate Fixture Hanger as 2631d Swing Gate Fixture Hanger Use with AS 200. Parallel Pipe Clamp as 3138 Cushion Strip as 3792 as 0040d thru as 106p Cushion Clamp Assembly klo-shure® strut-mounted Insulation Couplings with Strut Clamp Insulation Couplings with Non Metallic Strut Clamp klo-shure® strut-mounted Insulation Couplings for Fiberglass Insulation klo-shure® strut-mounted Concrete Inserts Screw Concrete Insert fig. AS 6153 3 – Use with AS 300. Use with AS 449 Insert.12 . AS 2511 2 – Use with AS 200 and AS 210. Use with AS 150 Channel. Use with AS 100 and AS 400 Channel. AS 6153 2 – Use with AS 200 and AS 210. AS 2511 3 – Use with AS 300. AS 200BTB and AS 210BTB Channels. with or without Closure Strip and End Cap Installed. Use with AS 200 Channel.com GL-7.anvilintl. Use with AS 300 Channel and AS 349 Insert. AS 400 and AS 500 Channels. AS 6153 5 – Use with AS 500. AS 210. .....................................................59 True Wye .......... 172 HDPE Flange Adapter.............. 127 Eccentric Reducer ................................................................... 137-138..................114-115..................................................... 145 Bullhead Tee Specialty Tee (GR x GR x FPT) .................54 Reducing Tee w/ Threaded Branch ......................... 96 www..................67 221⁄2° Long Radius Elbow ..............................................68 45° Long Radius Elbow .........................................................................................141..................................................................... 182 KNX Accessory Union ...................................................61 45° Adapter Elbow (GR x MPT) ............................ 146 Stainless Steel 90° Elbow-Type 304 .........................110...... 175-178 Tri-Service Valve (Straight) ................................67 111⁄4° Long Radius Elbow.....30-31....................... 122 CTS Copper Red..................147 Stainless Steel Conc.147 Cap ...................................... 161 Standard Coupling ...........63 Plain End Bull Plug .................67 45° Long Radius Elbow .....133-134............ 154 Standard Coupling ..........Page 7081P 7082 7082P 7084 7084P 7084SS 7085 7085P 7086 7087 7091 7097 7100 7101 7103 7105 7106 7107 7240 7250 7260 7305 7307 7312 7400 7400SS 7401 7401-2 7450 7460 7500 7600 7662EG 7700 7800 8000GR AF21-FF AF21-GF AF21-GG AF21-RFF AF21-RGF AU CA CU FTV-A FTV-S GAV-15 GAV-30 GBV-A GBV-G GBV-S GBV-T SV UV Adapter Nipple (Plain x THD) .. 130 Stainless Steel Reducing Tee-Type 316................. 174 Expansion Joints ............ 90-92..........131 Concentric Reducer (GR x THD) ............................................................132 Adapter Nipple (GR x MPT) ......... 182 Reducing Flex Connector (GR x FL) .....................67 30° Long Radius Elbow ....107 Automatic Air Vent ................................87-88 Circuit Balancing Valve (Sweat)......................131 HOSE Nipples (GR x Hose) ..................99-100...................68 60° Long Radius Elbow ...................................... 122 CTS Copper 45˚ Elbow....64 Female Thread Adapter (GR x FPT) ...........62 Stainless Steel 90° Elbow-Type 316 .............................................123 CTS Copper Conc............................................................ 129 Reducing Base Support Elbow (GR x FL) .................. 53 111⁄4° Long Radius Elbow.132 Swaged Nipple (GR x THD) ........................... 55 High Pressure Tee .............................. 168 Reducing Coupling...................119 Butterfly Valve ...... Adapter (GR x CUP) .................. 21-22................... 111....................................................................................132 Flange Nipple (GR x #150 FL) ........... 122 CTS Copper Reducing Tee (GR x GR x GR).89...................................................................................................... 165 Branch Outlet .....................58 Concentric Reducer (GR x GR)... 166 Clamp-T®................141..................................................................56 Stainless Steel Ecc..nuMErIcAL IndEX Fig....... 213 Suction Diffuser ....69 30° Long Radius Elbow ........ 75 High Pressure Header Tee .... Reducer-Type 304 .........................................................anvilintl................... 144 45° Elbow ..37-39 Outlet Coupling .....................67 60° Long Radius Elbow ...................49 Clamp-T®.. 146 Stainless Steel Tee-Type 304 .......................... 158 Stainless Steel Rigidlite® Coupling ..........65 Tee w/ Threaded Branch .. 144 Fig.................. 139...................................................................... 79-80 Grooved-End Silent Check Valve.....34-36.......................................108 Balancing Valve (Angle)................ FPT Branch ............. 60 Reducing Tee Wye .......104 Roll Groover.....56 Swaged Nipple (GR x GR) ......69 111⁄4° Elbow . 130 45° Lateral ........................23..............................20.............. 119 Plain End Cross.................................64 Adapter Nipple (Plain x BEV).....................50............................................................... 170 Roughneck® Coupling .Page 7052 7052i 7052-3D 7052-5D 7052-6D 7053 7053-3D 7053-5D 7053-6D 7055 7056 7057-3D 7057-5D 7057-6D 7058-3D 7058-5D 7058-6D 7060 7060EG 7060P 7060SS A7060SS 7061 7061P 7061SS A7061SS 7062 7063 7064 7065 7066 7067 7068 7068EG 7068P 7069 7069P 7070 7071 7071P 7072 7072i 7072SS A7072SS 7073 7073SS 7074 7074SS A7074SS 7075 7075P 7076 7077 7077P 7078 7079 7080 7080P 7081 221⁄2° Elbow.................................68 221⁄2° Long Radius Elbow ...................26-27................ 140.. 97 KNX Integral Ball Valve Union .................. 130 45° Reducing Lateral ........... Cross .. 124 CTS Copper Rigid Coupling ............................... 146 Stainless Steel 45° Elbow-Type 304 ........ 166 Clamp-T®. 179-181 Circuit Balancing Valve (Threaded). 53 Plain End 90° Long Radius Elbow ....... 70-74 Check Valve .................66 Ball Valve .......... 144 Bull Plug............... 124 CTS Copper End Cap ............................ 182 Flex Connector (GR x FL) .. 24-25.. 147 Flange Nipple (GR x #300 FL) ...................... 53 Plain End 45° Long Radius Elbow .......................................................................... 171 HDPE Transition Coupling .......83 Grooved-End “Wye” Strainer ...............99-100..............................................49 90° Elbow ........../Model description.....63 Stainless Steel Cap-Type 316 ............................................................................... 52 221⁄2° Elbow..............................................................81-82 Butterfly Valve ...................................... 55 Standpipe Tee (GR x GR x FPT).. 76-78 Flex Connector (FL x FL) ...148-149 CTS Copper 90˚ Elbow ..........62 Flange Nipple (Plain x #300 FL) ..........................69 90° Adapter Elbow (GR x MPT) ......128......................com GL-7........65 Tee Wye ................................121................................................ 156 Gruvlok Flange .....................................................66 Short Pattern Tee ................................ 122 CTS Copper Tee ..............118 90° Long Radius Elbow ....................../Model description...118 45° Long Radius Elbow .... 57 Adapter Nipple (GR x GR) .................................../Model description.................147 Stainless Steel Reducing Tee-Type 304 ......84-86 Butterfly Valve .................12 261 ..... Reducer-Type 316 ...............58 Stainless Steel Conc..............................18-19...... 173 Rigidlite® Coupling .................... 112....................65 High Pressure 90° LR Elbow....49 Clamp-T®..... 174 Coupling... 90-94 KNX CBV Union ........................................... 103 Grooved-End “Wye” Strainer .......................... 52 45° Long Radius Elbow .................. 105-106 Tee Strainer...44-46............ Cross ................... 174 Reducing Tee..........................................................................................................61 DI-LOK® Nipple (CTS GR x IPS GR) ................. 129 Stainless Steel Tee-Type 316 ...................... 57 Plain End Swaged Nipple ............54 Plain End Reducing Tee ...........................56 90° Elbow ..................................................................................................... 101-102 HDPE Coupling............................................................ 28-29....................... 169 Coupling with EG® Gasket .... 122 Adapter Nipple (GR x BEV).... 144 Reducing Tee Standard .................................................. 52 90° Long Radius Elbow ................................................................ 124 CTS Copper Flange Adapter................... Groove Branch .........................68 90° Long Radius Elbow ..............................40-41..............................................110...........................64 Adapter Nipple (Plain x GR) ...... 157 Standard Coupling ......................................................87-88 Balancing Valve (Straight) .............68 111⁄4° Long Radius Elbow..................................................................... Cross ........ 129 Stainless Steel 45° Elbow-Type 316 ........64 Fig......... 174 Reducing Outlet Tee ..69 High Pressure 45° LR Elbow ...............................................59 Plain End 45° Lateral..........62 Flange Nipple (Plain x #150 FL) ............ 182 Reducing Flex Connector (FL x FL).......... 140.............................69 Tee .......................................... 182 Flex Connector (GR x GR) .......................................................69 90° Drain Elbow ......................... 52 221⁄2° Long Radius Elbow ................................ 130 Concentric Reducer (GR x GR)............................................ 175-178 Automatic Air Vent .................................................................................................... 174 Straight Tee.................................................89.................61 60° Long Radius Elbow ................131 Plain End 45° Elbow ..........................42-43............Page 171 400G 758G 768G 1007 1715 3006 3007 6050 6051 6060 6061 6064 6072 6074 6075 6084 6400 6700 7000 7001 7001-2 7003 7004 7004 7005 7010 7011 7012 7013 7042 7044 7045 7046 7047 7048 7049 7050 7050-3D 7050-5D 7050-6D 7050DR 7050EG 7050LR 7050LRP 7050P 7050RF 7050SS A7050SS 7051 7051-3D 7051-5D 7051-6D 7051EG 7051LR 7051LRP 7051P 7051SS A7051SS Brass Ball Valve ........................................ 155 Hingelok® Coupling .................... 160 Coupling...........................................................145 Eccentric Reducer ...................................................63 High Pressure Cross.....90-92.........90-92.................... 109...125-126 Lightweight Coupling ............................................67 90° Long Radius Elbow .................................................. 167 Clamp-T®..................... 57 Swaged Nipple (GR x BEV).135-136..... 140.................... Reducer (GR x GR) .......................68 30° Long Radius Elbow ...............................................................47-48...................................... 146 Stainless Steel Cap-Type 304 ..... 119 Plain End Tee ..............................................................32-33.....150-151 Roll Groover....................................... 155 90° Short Pattern Elbow ............. 174 90° Reducing Elbow .... 130 Plain End 90° Elbow ................. 116-117.................. 142 Rigidlok® Coupling ............................. Reducer-Type 316.. 79-80 Roll Groover ........... 153 Rigidlok® Coupling .131 Stainless Steel Flange Adapter...............123 CTS Copper Reducing Tee (GR x GR x CUP) ............................148-149 Brass Ball Valve . 179-181 KNX Integral Ball Valve Strainer ....... 95 KNX CBV Accessory........................................ 60 Plain End 90° True Wye .. 60 Cross ........................................... 90-94 Tri-Service Valve (Angle) ............................................. 159 CTS Copper Butterfly Valve .. 162-164 Gruvlok Flange ................. Point of shipment. Seller neither assumes. If Seller examination shall disclose to its satisfaction that the products are defective. FREIGHT ALLOWANCE: All prices are F. material. NOTICE: The prices and terms quoted. TAXES: The amount of any sales. engineering design or fabrication is for nuclear plant applications. damage. and will accept no backcharge. shortages of fuel and energy. on delivery to the carrier.500 pounds or more. NOTE: All orders are accepted on the basis of prices in effect at the time of shipment. manufacture. MINIMUM INVOICE: Domestic: $100 plus transportation. or expense (whether or not based on negligence) directly or indirectly arising from delays or failure to give notice of delay.500 pounds) will be shipped prepaid. but Seller assumes no responsibility or liability. rail freight or motor freight at the lowest published rate. the liability of Seller for any personal injury (or death).B. In no case will more than actual freight be allowed. Anvil reserves the right to select the carrier for all shipments. shall be paid by Buyer unless Buyer provides Seller with an exemption certificate acceptance to the taxing authorities. 4. The cost of any special packing or special handling caused by Buyer’s requirements or requests shall be added to the amount of the order. 262 www. and title passes. use or repair of the products or of the engineering designs supplied to Buyer. material. labor difficulties. or any other causes of any kind whatever beyond the control of Seller. war. negligence or accidents. and further agrees to waive subrogation by its carriers of such insurance against Seller. Seller shall not be responsible for design errors due to inaccurate or incomplete information supplied by Buyer or its representatives. in the event that the delay in delivery or performance resulting from any of the aforesaid causes shall continue for a period of sixty (60) days. inability to obtain materials. 3. exception or commodity rate(s) or charge(s). any other obligation in connection with the sale of its engineering designs or products. point of shipment. On shipments weighing 2. Seller warrants the products which it sells of other manufacturers to the extent of the warranties of their respective makers. SPECIAL PRODUCTS: Orders covering special or nonstandard products are not subject to cancellation except on such terms as Seller may specify on application. counted and packed. 11. but are not taken. be found to be in first-class condition. 6. SELLER’S LIABILITY: Seller will not be liable for any loss. accident.O. alteration or modification is specifically accepted in writing and signed by an authorized representative of Seller. property damage or other loss directly caused by defective design. All prices are F. excise or other taxes. unless otherwise stated. if not prepaid will be deducted from credit memoranda. EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FOR A PARTICULAR PURPOSE WHICH EXCEED SELLER’S AFORESTATED OBLIGATION ARE HEREBY DISCLAIMED BY SELLER AND EXCLUDED FROM THIS WARRANTY. 12. Buyer shall hold Seller harmless against all such losses which could have been thus covered (b) Buyer agrees to hold Seller harmless with respect to any personal injury (or death). highway points listed in published tariffs (Alaska and Hawaii excluded). No waiver.S. 9. 7. PRICES AND DESIGNS: Prices and designs are subject to change without notice. The buyer will be invoiced for freight costs at the applicable published class. Buyer agrees (a) to take all necessary steps to add Seller as an insured under the American Nuclear Insurers’ (ANI) pool and under the Mutual Atomic Energy Reinsurance Pool (MAERP) for property damage and liability insurance and if necessary steps could have been taken. sale.11 . DELIVERY: Seller will make every effort to complete delivery of products as indicated on Seller’s acceptance of an order. if not. This warranty shall not apply to any products or parts of products which (a) have been repaired or altered outside of Seller’s factory. for loss or damage due to delay or inability to deliver caused by acts of God. nor authorizes any person to assume for it. RETURNS: Seller cannot accept return of any products unless its written permission has been first obtained. International: $500 plus transportation. 10. or workmanship furnished by Seller shall not exceed the value at the time of the loss occurrence. 8. as Seller’s responsibility ceases. the amount of such adjustment shall not exceed the net sales price of the defective products only and no allowance will be made for labor or expense of repairing or replacing defective products or workmanship of damage resulting from the same. in which case same will be credited subject to the following (a) All material returned must. 2. rail points or all U. SELLER MAKES NO OTHER WARRANTY OF ANY KIND. and an adjustment is required. cost of putting in saleable condition will be deducted from credit memoranda. property damage or other loss in a nuclear incident which is caused directly or indirectly by defective design.tErMS & condItIonS 1. contract or negligence. alteration or modification of these terms and conditions whether on Buyer’s purchase order or otherwise shall be valid unless the waiver.O. Claims for products damaged or lost in transit should be made on the carrier. TERMS: Cash. Under no circumstances shall Seller be liable for any special or consequential damages or for loss. there will be added any manufacturers or sales tax payable on the transaction under any effective statute. Shipments (weighing less than 2.com GL-6. No claim for shortages will be allowed unless made in writing within ten (10) days of receipt of a shipment. other than expressed in Seller’s product warranty. (c) have been used in a manner contrary to Seller’s instructions or recommendations. Where engineering design or fabrication work is supplied. cost of repairs. Buyer’s acceptance of Seller’s design or of delivery of work shall relieve Seller of all further obligation. NUCLEAR PLANTS: Where the products. SHIPMENTS: All products sent out will be carefully examined. and (c) as to nuclear hazards for which Buyer cannot obtain insurance coverage. workmanship furnished by Buyer (or which could be so covered but with respect to which Buyer has elected to self-insure).anvilintl.B. on its arrival at Seller’s Plant. whether based upon warranty (except for the obligation accepted by Seller under “Warranty” above). CONTROLLING PROVISIONS: These terms and conditions shall control with respect to any purchase order or sale of Seller’s products. delays of carriers. damage. arising in connection with the design. is allowed to all continental U. in any manner: (b) have been subjected to misuse. if any. 5. by written notice to Buyer.S. by contractors or suppliers. Seller may terminate any contract of sale of its products without liability of any nature. WARRANTY: Seller warrants for one year from the date of shipment Seller’s manufactured products to the extent that Seller will replace those having defects in material or workmanship when used for the purpose and in the manner which Seller recommends. incidental or consequential damages of any kind. (c) Transportation charges. (b) A handling charge deduction of twenty percent (20%) will be made from all credit memoranda issued for material returned. net 30 days unless otherwise specified. applicable to the products covered by this order. THIS IS SELLER’S SOLE WARRANTY. 10 Conc. 10 Tee 304L Sch. Wt. Wt.Ductile Iron Sch. 768 Available GBV-G 722 SF21-GF 7050RF 3006/C 3007 Di-Electric Nipple Expansion Joint Butterfly Valves Large Silent Check Valve Butterfly Valve Large Butterfly Valve Check Valve Ball Valve Tee Strainer Suction Diffuser Wye Strainer Venturi .Copper Copper Conc.i.Gruvlok Cross referenCe victaulic® 07/107 07/107 45/46 72 75 77 78 99 741/743 995/997 ES FS Grade E Grade L Grade O Grade T HP-70 HP-70ES NA Gruvlok® Couplings & Gaskets 7400 7401 7084/7085 7042FF 7000 7001 7003 7005 7012/7013 7305/7307 EG FG Grade E Grade L Grade O Grade T 7004HPR 7004EG 7400 Rigidlite® Coupling Rigidlok® Coupling Flg x Grv Adapter-150/300# Outlet Coupling fnpt Lt.316SS Rigid Coupling . Reducer 304L Sch. 10 Cap 304L Sch. G x G Copper Reducing Tee. Flexible Coupling Lt. F x G Grooving Tools Grooving Tools victaulic® 001 002 75 005 27 61 96 705W 717 750 920 920 920 925 961 Gruvlok® fire Protection 7450 7460 7000A 7400A 7065 7075 7105 7722-3D 78FP 7010 7045 7046 7048 7044 7100 90˚ Ell (Short Pattern) Tee (Short Pattern) Lt. G x C Flange . 10 Reducing Tee 304L Sch. G x C Copper Cap Copper Ball Valve victaulic® 489 89 20-SS 20-SS-SW 50-SSLT 51-SSLT 60-SS 100-SS 110-SS 721S Gruvlok® stainless steel 7400SS 7401 7060-SS04 7061-SS04 7072-SS04 7073-SS04 7074-SS04 7050-SS04 7051-SS04 7500SS Rigid Coupling . 10 45˚ Ell 304L SS Ball Valve www.Grooved Balancing Valve Triple Service Valve Flex Connector. Rigid Sprinkler Coupling Standpipe Tee Bull Plug Sock-It® Reducing Tee UL/FM Butterfly Valve w/s UL/FM Valve Reducing Coupling Clamp Tee Fnpt Outlet Clamp Tee Grooved Outlet Clamp Cross Econ.anvilintl. Rigid Coupling victaulic® 10 10-P 11 12 13 20 25 29M 29T 30 30R 32 32R 33 43/40 50 51 52 53 60 80 100 110 Gruvlok® fittings 7050 7050P 7051 7052 7053 7060 7061 7063 7064 7069 7070 7066 7067 7071 7080/7081 7072 7073 7076 7077 7074 7087 7050LR 7051LR 90˚ Ell Plain-End 90˚ Ell 45˚ Ell 221/2˚ Ell 111/4˚ Ell Tee Reducing Tee Tee with Threaded Branch Reducing Tee with Threaded Branch Lateral 45˚ Reducing Lateral 45˚ True Wye Reducing Tee Wye True Wye Nipples. Reducer. Reducer 304L Sch.Copper Copper Butterfly Valve Copper 90˚ Ell Copper 45˚ Ell Copper Tee Copper Reducing Tee.12 263 .com GL-10. Wt. G x G/G x T Concentric Reducer Eccentric Reducer Reducer Groove x Thread Swaged Reducer Nipple Cap Female Threaded Adapter Long Radius 90˚ Ell Long Radius 45˚ Ell victaulic® 47 155 300 416 700 709 716 721 730 731 732 733 789 NA NA R-10F VE272 VE416 Gruvlok® Mechanical 7088/7089 7240 7700 400G 7600 8000 7811 7500 7260 7250 758. F x G Base Ell Reducing.s. G x G Copper Conc. 10 90˚ Ell 304L Sch. Clamp Tee Fnpt Sock-It® 90˚ Ell Copper victaulic® 606/607 608 610 611 620 625 626 641 650 652 660 NA Gruvlok® CTs Copper Product 6400 6721 6050 6051 6060 6061 6064 6084 6072 6075 6074 7500B Rigid Coupling . Flexible Coupling Flexible Coupling Hinge Coupling Rough Neck Coupling Grooved Flange-150/300# HDPE Coupling End Guard Gasket Flush Gap Gasket Gasket EPDM Gasket Silicone Gasket Viton Gasket Nitrile HPR Coupling End Guard Coupling 300 p. Reducer. 10 Ecc. com .notES 264 www.anvilintl. TRUSTED FOR 150 YEARS We built our reputation from the ground up. 1969 Grinnell Co. Inc. but keeps the manufacturing and sales divisions that will become known as Anvil® International. 1999 Tyco sells the distribution and manufacturing operations known up to this point as ”Grinnell Supply Sales”. Companies express interest in buying its piping products. when a company named Grinnell® began providing its customers with the finest quality pipe products. 1919 General Fire Extinguisher Co.Today Anvil® International is the largest and most complete fitting and hanger manufacturer in the world. Supports and Struts Beck Welded Pipe Nipples Anvil ® Seamless Pipe Nipples Anvil Steel Pipe Couplings and Small Steel Fittings ® 1994 J. RI. Grinnell® is a registered trademark of Grinnell Corporation. Focused Product Line: Anvil ® Malleable and Cast Iron Fittings Anvil ® Hangers. company. ITT divests the Fire Protection Division. a Tyco International Ltd. 2000 The industry’s trusted manufacturer of pipe fittings. hangers and grooved fittings is renamed Anvil® International. laying the groundwork for what would become the Grinnell Supply Sales Division. acquired by International Telephone and Telegraph. and Frederick Grinnell purchases a controlling interest. Smith Swage Nipples and Bull Plugs Catawissa ® Wing Unions and Check Valves 1960 Gruvlok® line of grooved fittings is introduced. becomes Grinnell Co.B. B U I L D I N G C O N N E C T I O N S T H A T L A S T ANVIL BRANDS: . Since 2000. It would be these manufacturing and sales operations that eventually become Anvil® International. Fittings and Valves SPF TM Malleable and Cast and Ductile Iron Fittings SPF TM Grooved Fittings and O’Lets J. Anvil’s history stretches back to the mid 1800s.B. Merit ® Tee-Lets and Drop Nipples 1909 Frederick Grinnell opens a foundry in Cranston. those quality products and services— and the people who provide them—have been known as Anvil® International. Anvil® customers receive the quality and integrity that have been building strong connections in both products and business relationships for over 150 years. Smith™ and Catawissa™ join the Grinnell Supply Sales and Manufacturing division. Building and Construction TM Divisions (SPF) and forms AnvilStar Fire Products Division. 1850 Providence Steam & Gas Pipe Co. Gruvlok ® Couplings. is formed. 2001 Anvil® International acquires Merit® Manufacturing and Beck Manufacturing. Two years later. but keeps the Grinnell® trademark. 2004 Anvil® International acquires Star Pipe Products. PiPe Fittings Catalog Order dOcument #010 PiPe Hangers & suPPort Catalog Order dOcument #165 anvil-strut Metal FraMing ProduCt & engineering Catalog Order dOcument #125 PiPe Fitters Handbook Order dOcument #030 gruvlok MeCHaniCal PiPing ProduCts Catalog Order dOcument #040 . for Use in Steel Pipe Joints. FM Approved. Anvil EPS brings the highest quality products and innovative engineering solutions to common and uncommon piping system problems. The Gruvlok product line consists of couplings for grooved and plain-end fittings. where space and pipe line separation are a consideration. All products can be ordered in an assortment of finishes and material choices including SupR-Green™. pipe hangers and supports. API couplings are manufactured in accordance with the API Specification for line pipe. JB Smith™ is the leading manufacturer of oil country tubular fittings. butterfly valves and check valves. Steel pipe nipples and steel pipe couplings are manufactured in accordance with the ASTM A733 Standard Specification for Welded and Seamless Carbon Steel and Stainless Steel Pipe Nipples. In addition. and are interchangeable with most leading union manufacturers. Canvil® manufactures low pressure hexagon reducer bushings. Fully traceable and available with complete mill certifications. aluminum.B r A n d s o f A n v i l i n t e r n At i o n A l Anvil® product lines include malleable and cast iron fittings. electro-galvanized. Black or Zinc-Coated (Galvanized) Welded or Seamless. unions and flanges. JB Smith is the resource for all your oilfield needs. cast iron. malleable iron and ductile iron threaded fittings. seamless and welded steel pipe nipples. pipe grooving tools. with custom lengths available upon request. threaded rod. The SPF/Anvil™ product line includes a variety of internationally sourced products such as grooved couplings. Zinc Trivalent Chromium. Anvil EPS-Engineered Pipe Supports are products used to support piping systems under thermal. seismic. forged steel couplings and bar stock products offered as either as normalized (A105N) or non-normalized (A105) that are fully traceable for mechanicals and chemistry through our MTR program. forged steel fittings and unions. universal anvilets. plain. swages and bull plugs – all meeting API specifications. ® The Merit® product line includes a variety of tee-lets. pre-galvanized. Anvil-Strut™ products include a complete line of channel in stock lengths of 10 and 20 feet. Canvil manufactures A105 hex or round material in class 3000 and 6000 pound. flanges. Catawissa™ NACE and API approved wing unions for Standard Service are offered in non-pressure seal ends as well as threaded and butt weld. as well as copper and stainless steel system components. steel pipe nipples. The product line encompasses variable spring hangers. Phosphate and Electro Galvanized. steel pipe couplings. and engineered hangers. . as well as plugs and hex caps up to 1” in diameter in various finishes including Oil Treat. casing nipples as well as a full line of traditional line pipe and oil country threads in every schedule. and steel welding flanges for fire protection applications. drop nipples. constant supports. as well as o’lets. A variety of fittings and accessories are also offered. pump protection components. Steel. Catawissa’s oilfield wing union product line includes the standard ball-and-cone design plus our unique Figure 300 Flat Face design. Offering tubing nipples. and rated from 175 to 300 psi. Steel pipe couplings are manufactured in accordance with the ASTM A865 Standard Specification for Threaded Couplings. and other dynamic loading conditions. fittings and flanges. sway struts and snubbers as well as standard and special design clamps. and stainless steel. hot-dip galvanized. Most Merit products are UL/ULC Listed. Canada *Inventory varies at locations b u i l d i n g c o n n e c t i o n s t h a t l a s t Innovators of Pipe Fabrication Equipment North Alabama Pipe www. Vintage Avenue Ontario. Ontario Tel: 519-426-4551 • Fax: 519-426-5509 u.s. PA 17512 irvinG 1401 Valley View Lane. Indiana. Minnesota.anvilintl. TX Tel: 972-871-1206 • Fax: 972-641-8946 Toll Free: 1-800-451-4414 europe And middle eAst Tel: +31-53-5725570 • Fax: +31-53-5725579 International Customer Service Tel: +1-708-885-3000 • Fax: +1-708-534-5441 mexico. Colorado. puerto rico And lAtin AmericA International Customer Service Tel: +1-708-885-3000 • Fax: +1-708-534-5441 cAnAdA Simcoe. Tennessee. Washington and Wisconsin internAtionAl: Ontario. IL 60484 Anvil eps Engineered Pipe Supports Customer Service Center 160 Frenchtown Road North Kingstown. Missouri. NH 03833 Tel: 603-418-2800 • Fax: 603-418-2833 E-mail: sales@anvilintl. Georgia. IL Tel: 708-885-3000 • Fax: 708-534-5441 Toll Free: 1-800-301-2701 Irving. TX 75061 ontArio 1470 S. Massachusetts.com #040/Printed in USA/© Copyright 2012 Revision Date: 10. CA 91761 additional inventorY locAtions* united stAtes: Arizona.12 . New York.24.com customer service centers united stAtes University Park.corporAte offices 2 Holland Way Exeter. Texas. RI 02852 Tel: 401-886-3000 Fax: 401-886-3010 Toll Free: 1-877-406-3108 columBiA 800 Malleable Road Columbia. Suite 150 Irving. reGionAl distriBution centers universitY pArK 750 Central Avenue University Park.