Goodman Airhandler Manual



Comments



Description

PRODUCT SPECIFICATIONSARUF SERIES MULTI-POSITION THREE-SPEED AIR HANDLER WITH GALVANIZED CABINET 1½ TO 5 TON The Goodman® brand 2006 ARUF Multi-Position Air Handler is suitable for use with refrigerants R-410A and R-22. (Please note Nomenclature Chart on Page 2.) This unit features a check flowrater expansion device and may be installed in a variety of locations. Standard Features • Certain models are suitable for use with refrigerants R-410A and R-22 (see Nomenclature Chart on Page 2). • Check flowrater expansion device for coolingonly and heat pump applications • Direct-drive, multi-speed motor • Transformer and blower time-delay on all units Cabinet Features • Rust-resistant, fully insulated steel cabinet • Galvanized, stucco-embossed finish • Attractive Architectural Gray painted front panels • Built-in coil has horizontal, vertical and downflow drain pans with secondary drain connections • Built-in filter rack for 1” filter (filter not included) • Power supply entry at top; low-voltage entry on left side and top Accessories • 3 kW to 21 kW electric heat kits available as field-installed options • Permanent washable plastic air filters (FIL18-32, FIL36-42, FIL48-61) • Thermal Expansion Valve Kits for air conditioning-only applications • Coil Insulation Kits for downflow applications (DPI 1830, DPI 3642, DPI 4861) • Horizontal drain pan insulation kits (DPIH 18-32, DPIH 36-42, DPIH 48-61) SS-GARUF www.goodmanmfg.com 5/06 Supersedes 4/06 60 Hz Cabinet Finish U = Unpainted P = Painted N = Uncased Application C = Ceiling Mount PSC Motor D =Downflow PSC Motor E = Multi-Position Variable-Speed Motor R = Multi-Position PSC Motor W = Wall Mount PSC Motor Major/Minor Revisions A = Revision (Not used for inventory management) Refrigerant Charge No Digit = R-22 only 6 = R-410A or R-22 Nominal Capacity Range @ 13 SEER Multi-Position & Downflow Applications 3642 = Nominal Capacity @ 13 SEER.PRODUCT SPECIFICATIONS NOMENCLATURE A R Product Type A = Single Piece Air Handler U F 3 6 4 2 1 6 A A Expansion Device F = Flowrater T = Expansion Valve Electrical 1 = 208/240 V 1-Phase.11/2 to 21/2 Tons (for Export Systems) Ceiling Mount & Wall Mount Applications 1805 = Nominal Cooling Capacity/Electric Heat kw 11/2 Tons Cooling/ 5 kw Electric Heat 2405 = Nominal Cooling Capacity/Electric Heat kw 2 Tons Cooling/ 5 kw Electric Heat 3608 = Nominal Cooling Capacity/Electric Heat kw 3 Tons Cooling/ 8 kw Electric Heat 2 SS-GARUF .3-31/2 Tons 1830 = Nominal Capacity @ 13 SEER.1½-3½ Tons 1729 = Nominal Capacity @ 10 SEER . 4/5.ARUF032.ARUF06100A1/1A 00A1/1A 00A1B 00A1/1A 00A1B 00A1/1A 00A1B 00A1/1A 00A1/1A 00A1B Specifications Blower Diameter 9½” 9½” 9½” 9½” 9½” 9½” 10⅝” 10⅝” 10⅝” 10⅝” Width 6” 6” 6” 8” 8” 8” 8” 8” 10⅝” 10⅝” Coil Drain Connection FPT ¾” ¾” ¾” ¾” ¾” ¾” ¾” ¾” ¾” ¾” Liquid ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” Suction ¾” ¾” ¾” ¾” ¾” ⅞” ⅞” ⅞” ⅞” ⅞” Service Valve Electrical Data Voltage Min Circuit Ampacity 208/240 1.2 2.48 2.ARUF042.3/3.ARUF032.1/2.8 3.ARUF042.6 2.4 Electrical Data Voltage Min Circuit Ampacity 208/240 MOD* (amps) 3.3 MOD* (amps) 4.1/2.95 3.9/1.ARUF061.ARUF049.7/3.9/4.PRODUCT SPECIFICATIONS SPECIFICATIONS ARUF1729 1/16 ARUF1824 1/16 ARUF1931 1/16 ARUF3030 1/16 ARUF3642 1/16 ARUF3743 1/16 ARUF4860 1/16 9½” 9½” 9½” 9½” 10⅝” 1115/16” 10⅝” Width 6” 6” 6” 8” 8” 1011/16” 10⅝” Coil Drain Connection FPT ¾” ¾” ¾” ¾” ¾” ¾” ¾” Specifications Blower Diameter Service Valve Liquid ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” Suction ¾” ¾” ⅞” ¾” ⅞” ⅞” ⅞” 2.39 4.95 3.4/5.4 15/15 Minimum VAC 197 197 197 197 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 253 253 253 253 FLA 1.64 2.4/2.ARUF049.2 5.95 1.9 3.7 4.7 2.3 HP 1/5 ⅓ ⅓ ½ ⅓ ½ ½ ½ ¾ ¾ Ship Weight (lbs) 106 120 120 144 144 173 173 173 192 173 Blower Motor * Maximum Overcurrent Protection Device SS-GARUF 3 .6 2.8/2.2/4.3 HP ⅓ ⅓ ¼ ⅓ ½ ½ ¾ 110 120 155 144 173 195 192 Blower Motor Ship Weight (lbs) * Maximum Overcurrent Protection Device ARUF024.7 1.1 2.9 4.1/2.9 2.7 1.4 2.ARUF060.5 1.9/1.3/3.1 1.3 15/15 Minimum VAC 197 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 253 FLA 1.1 2.6 3.9 5. 30 cm] Model A B C D E F G H I J ARUF17291* 42⅛” 22” 13½” 15½” 10” 14½” 11 /16” 13⅛” 17 /16” 2” ARUF18241* 42⅛” 22” 13½” 15½” 10” 14½” 1115/16” 13⅛” 1715/16” 2” ARUF19311* 46¾” 22” 17½” 19½” 10” 14½” 11 /16” 17⅛” 17 /16” 2” ARUF30301* 46¾” 22” 17½” 19½” 10” 14½” 1115/16” 17⅛” 1715/16” 2” ARUF36421* 53¼” 24” 20” 22” 12” 14½” 11 /16” 19⅝” 19 /16” 1 /16” ARUF37431* 53¼” 24” 20” 22” 12” 14½” 1115/16” 19⅝” 1915/16” 113/16” ARUF48601* 53¼” 24” 20” 22” 12” 14½” 1115/16” 19⅝” 1915/16” 113/16” ARUF02400A1A 42⅛” 22” 13½” 15½” 10” 14½” 1115/16” 13⅛” 1715/16” 2” ARUF03200A1B 42⅛” 22” 13½” 15½” 10” 14½” 11 /16” 13⅛” 17 /16” 2” ARUF04200A1B 46¾” 22” 17½” 19½” 10” 14½” 1115/16” 17⅛” 1715/16” 2” ARUF04900A1B 53¼” 24” 20” 22” 12” 14½” 11 /16” 19⅝” 19 /16” 1 /16” ARUF06100A1B 53¼” 24” 20” 22” 12” 14½” 1115/16” 19⅝” 1915/16” 113/16” 4 15 15 15 15 15 15 15 15 15 15 13 13 SS-GARUF .PRODUCT SPECIFICATIONS DIMENSIONS J 2 ⅞” [7. 851 1.025 965 915 Med 860 825 780 750 680 Low 600 570 545 500 465 High 1.140 1.050 Low 1.417 1.025 950 895 Med 875 830 790 750 715 Low 640 610 570 535 490 High 1.155 1.480 1.030 980 910 840 High 1.231 1.280 1.340 1.780 Med 1.090 1.290 1.230 1.534 Med 1.984 1.935 1.680 1.860 1.205 High 2.380 1.000 1.715 1.875 1.090 1.276 1.3” 0.670 1.562 1.345 1.934 1.805 Med 1.090 1.323 Low 1.065 2.499 1.182 1.090 Med 1.312 1. SCFM correction for wet coil = 4% SS-GARUF 5 .020 980 920 870 Low 935 910 880 850 790 High 1.902 Med 1.320 1.032 Low 1.051 1.530 High 1.385 1.455 1.975 1.025 950 895 Med 875 830 790 750 715 Low 640 610 570 535 490 High 1.075 1.470 1.080 1.775 1.085 1.778 1.985 1.706 1.718 Low 1.500 1.016 956 890 890 High 1.195 High 2.700 1.1” 0.437 1.490 1.675 Low 1.135 2.5” High 1.645 1.676 1.685 1.280 1.330 1.644 1.345 1.532 1.068 Med 1.PRODUCT SPECIFICATIONS BLOWER PERFORMANCE Model ARUF17291/16 ARUF18241/16 ARUF19311/16 ARUF30301/16 ARUF36421/16 ARUF37431/16 ARUF48601/16 ARUF02400A1/1A ARUF03200A1B ARUF04200A1B ARUF04900A1B ARUF06100A1B CFM delivered against External Static Pressure Motor Speed 0.900 1.379 1.135 1.353 1.267 1.610 1.056 1.155 1.192 2.2” 0.346 1.590 1.477 1.440 1.124 2.606 1.410 Low 1.901 1.020 950 900 Med 870 830 790 750 710 Low 640 610 570 530 490 High 1.550 1.230 1.425 1.318 1.650 1.116 1.635 1.205 1.147 High 2.325 Low 1.482 Note: Assumes dry coil with filter in place.925 1.052 1.609 1.672 1.4” 0.150 1.535 Med 1.207 1.275 1. HKR-08C* X1 X1 X1 X X X X HKR-10*. HKR-08C* X X1 X X X HKR-10*.6 or higher. HKR-10C* X1 X1 X1 X X X2 X2 X3 X HKR-20C* X2 X3 X HKR-21C* X2 X3 X ^ HKR3-15* X2 X3 X ^ HKR3-20* X2 X3 X HKR-15C* * Revision level that may or may not be designated C Circuit breaker option ^ Heat kit requires three-phase power supply 1 Air handler must either be on medium or high speed 2 Air handler must be on high speed 3 For static pressure of 0.6 or higher. air handler must be on medium or high speed 6 SS-GARUF . air handler must be on medium or high speed ARUF02400A1A ARUF03200A1B ARUF04200A1B ARUF04900A1B ARUF06100A1B HKR-03* X X X X X HKR-05*. HKR-05C* X X X X X HKR-06* X X X X X HKR-08*. HKR-05C* X X X X X X X HKR-06* X X X X X X X HKR-08*. HKR-10C* X1 X1 X1 X1 X X X HKR-15C* X2 X2 X2 X2 X3 X3 X HKR-20C* X2 X3 X3 X HKR-21C* X2 X3 X3 X ^ HKR3-15* X2 X3 X3 X ^ HKR3-20* X2 X3 X3 X * Revision level that may or may not be designated C Circuit breaker option ^ Heat kit requires three-phase power supply 1 Air handler must either be on medium or high speed 2 Air handler must be on high speed 3 For static pressure of 0.PRODUCT SPECIFICATIONS ACCESSORIES HEAT KIT APPLICATIONS ARUF1729 1/16 ARUF1824 1/16 ARUF1931 1/16 ARUF3030 1/16 ARUF3642 1/16 ARUF3743 1/16 ARUF4860 1/16 HKR-03* X X X X X X X HKR-05*. ) EXPANSION VALVE KITS FOR AIR CONDITIONING-ONLY APPLICATIONS Kit Number XVB18-36C XVB42-60C XV18-36C XV42-60C EXPANSION VALVE KITS Used with ARUF01824 to ARUF01931 ARUF03642 to ARUF04860 ARUF01824 to ARUF01931 ARUF03642 to ARUF04860 FOR AIR CONDITIONING AND FOR R-22 SYSTEMS Description 20% bleed valve 20% bleed valve Non-bleed valve Non-bleed valve HEAT PUMP APPLICATIONS FOR R-410A SYSTEMS Valve Description Used with Outdoor Units below Valve Description Cap Used with Outdoor Units below TX3N2 Non-bleed valve 3 Ton > Air Conditioner & Heat Pump TX3N4 Non-bleed valve 3 Ton > Air Conditioner & Heat Pump TX5N2 Non-bleed valve 3½ Ton < Air Conditioner & Heat Pump TX5N4 Non-bleed valve 3½ Ton < Air Conditioner & Heat Pump DRAIN PAN INSULATION KIT FOR DOWNFLOW APPLICATIONS Chassis Size Insulation Kit Small (15½”) DPI18-30/20 Medium (19½”) DPI36-42/20 Large (22”) DPI48-60/20 Note: Each kit contains enough material to modify 20 coils FILTERS ARUF 1729/1824 1931 3030 3642 3743 4860 SS-GARUF Filter # FIL 18-32 FIL-36-42 FIL-36-42 FIL 48-61 FIL 48-61 FIL 48-61 Qty Required 1 1 1 1 1 1 7 .PRODUCT SPECIFICATIONS ACCESSORIES (CONT. Copyright © 2006 • Goodman Manufacturing Company. reserves the right to discontinue. L. • Houston.P. 8 SS-GARUF . or change at any time. Printed in the USA.P.PRODUCT SPECIFICATIONS Goodman Manufacturing Company.. specifications or designs without notice or without incurring obligations. L. Texas Goodman® brand products are made proudly in the USA.
Copyright © 2024 DOKUMEN.SITE Inc.