HIGH PERFORMANCE STEEL ANCHORSfischer Bolt FBN The flexible anchor – for economical performance. Suitability Suitable for: Concrete so ≥ B15, natural stone with dense structure. For fixing of: Metal constructions, metal profiles, sole plates, brackets, railings, windows, gratings, machines, timber constructions (large washer), beams, purlins, supports etc. 1 2 3 4 fischer Bolt FBN, zinc plated and passivated steel fischer Bolt FBN with large washer, zinc plated and passivated steel fischer Bolt FBN, A4 stainless steel* fischer Bolt FBN fvz (hot dipped galvanized)* * not included in approval notice. 1 Description The fischer FBN bolt is a more advanced development of the FB and now offers even more scope for application. In concrete terms, this means that the FBN can be installed with a variable embedment depth, i.e. the user has the choice between the standard embedment depth with maximum permitted load and an extended useful length with a reduced permitted load. The thread has been extended with this in mind. 2 3 4 Installation instructions ½ Before tapping in, place the nut in the best position for installation (bolt projects approx. 2–3 mm). ½ The letter engraved on the head of the anchor is required for approval reasons and identifies the FBN in its installed state. Advantages ½ Through its variable useful length (see description) and the extended thread, the FBN offers increased scope for use. ½ The expansion clip has been improved, resulting in increased load values, even in low-quality concrete. ½ Anchoring with the FBN is now even more economical. ½ The FBN can be anchored with only a few turns. ½ A special assortment with a large washer to DIN 440 is available for use with wood. Approvals Fire resistance classification F 90 Installation diagram 32 HIGH PERFORMANCE STEEL ANCHORS fischer Bolt FBN Technical data FBN – zinc plated and passivated steel do Imprint Steel on gvz head Art. No. FBN – A4 stainless steel td Min. drill-hole depth for through fixing mm hef Min. anchorage depth mm l tfix Max. fixing thickness mm M FBN – fvz (hot dipped galvanized) do td Min. drill-hole depth for through fixing mm hef Min. Anchorage depth mm l tfix Max. fixing thickness mm M Type Steel A4* Art. No. Drill mm Overalllength mm Thread x length Qty. per pack Type Steel fvz* Art. No. Drill mm Overall length mm Thread x length Qty. per pack FBN 6x40* FBN 6x55* FBN 6x70 FBN 6x75* FBN 6x90 FBN 8x60 FBN 8x75 FBN 8x95 FBN 8x115 FBN 8x165 FBN 10x70 FBN 10x90 FBN 10x110 FBN 10x125 FBN 10x175 FBN 10x215 FBN 10x235 FBN 12x85 FBN 12x115 FBN 12x130 FBN 12x145 FBN 12x200 FBN 16x110 FBN 16x145 FBN 16x170 FBN 16x220 FBN 20x120* FBN 20x165 FBN 20x205 FBN 20x265 FBN 20x395 – – – – – – B F K P – C G K P S T – C F I P – E K P – – – – – 45130 45136 – 45137 – 45131 45138 45139 45140 45141 45132 45142 15399 45143 45144 45145 45146 45133 45147 45148 45149 45150 45134 45151 45152 45153 45135 45154 45155 45156 45157 – – 69087 – 69088 – 69089 69090 69091 – – 69092 – 69093 69094 – – – 69095 – 69096 69097 69098 69099 69100 – – – – – – 6 6 6 6 6 8 8 8 8 8 10 10 10 10 10 10 10 12 12 12 12 12 16 16 16 16 20 20 20 20 20 45 50 65 70 85 55 73 93 113 163 65 83 103 118 168 208 228 75 105 120 135 190 98 133 158 208 111 151 191 251 381 20 25 40 25 40 35 48/35 48/35 48/35 48/35 42 50/42 50/42 50/42 50/42 50/42 50/42 50 70/50 70/50 70/50 70/50 64 84/64 84/64 84/64 70 100 100 100 100 40 55 70 75 90 60 75 95 115 165 70 90 110 125 175 215 235 85 115 130 145 200 110 145 170 220 120 165 205 265 395 5 10 10 30 30 5 10/23 30/43 50/63 100/113 5 15/23 35/43 50/58 100/108 140/148 160/168 5 15/35 30/50 45/65 100/120 10 25/45 50/70 100/120 10 20 60 120 250 M 6 x 16 M 6 x 30 M 6 x 25 M 6 x 30 M 6 x 30 M 8 x 23 M 8 x 41 M 8 x 61 M 8 x 81 M 8 x 130 M10 x 31 M10 x 51 M10 x 71 M10 x 87 M10 x 134 M10 x 174 M10 x 194 M12 x 41 M12 x 71 M12 x 86 M12 x 103 M12 x 157 M16 x 54 M16 x 89 M16 x 114 M16 x 166 M 20 x 50 M 20 x 50 M 20 x 90 M 20 x 90 M 20 x 90 100 100 100 100 100 100 50 50 50 25 50 50 50 20 20 20 20 20 20 20 20 20 10 10 10 10 10 10 10 10 5 FBN 8x60 HDG* FBN 8x75 HDG* FBN 8x115 HDG* FBN 8x165 HDG* FBN 10x70 HDG* FBN 10x90 HDG* FBN 10x125 HDG* FBN 10x175 HDG* FBN 10x215 HDG* FBN 12x85 HGD* FBN 12x115 HDG* FBN 12x130 HDG* FBN 12x145 HDG* FBN 12x200 HDG* FBN 16x110 HDG* FBN 16x145 HDG* FBN 16x170 HDG* FBN 16x220 HDG* 57525 57526 57527 57528 57529 57530 57531 57532 57533 57534 57535 57536 57537 57538 57539 57540 57541 57542 8 8 8 8 10 10 10 10 10 12 12 12 12 12 16 16 16 16 55 73 113 163 65 83 118 168 208 75 105 120 135 190 98 133 158 208 35 48 48 48 42 50 50 50 50 50 70 70 70 70 64 84 84 84 60 75 115 165 70 90 125 175 215 85 115 130 145 200 110 145 170 220 5 10 50 100 5 15 50 100 140 5 15 30 45 100 10 25 50 100 M 8 x 23 M 8 x 41 M 8 x 81 M 8 x 130 M10 x 31 M10 x 51 M10 x 87 M10 x 134 M10 x 174 M12 x 41 M12 x 71 M12 x 86 M12 x 103 M12 x 157 M16 x 54 M16 x 89 M16 x 114 M16 x 166 100 50 50 25 50 50 20 20 20 20 20 20 20 20 10 10 10 10 * Not included in approval notice. Mean ultimate loads and recommended loads for single anchors of fischer bolt FBN with large axial spacing and edge distance Non-cracked concrete Anchor size M6 M8 M10 50 68 10 22.4 20.9 30.5 16.6* 19.1* 24.0* 5.8 5.8 5.8 7.5 7.5 7.5 50 70 12 25.6 – 30.5 27.6 – 31.6* 7.5 – 7.5 7.5 – 7.5 M12 70 90 12 35.0 35.2* 39.9* 27.6* 27.6* 31.6* 64 88 16 35.0 – 38.2 33.4* – 56.5* M16 84 108 16 M20 100 131 20 Effective anchorage depth heff [mm] 40 35 48 42 Drill hole depth h1 [mm] 55 50 63 60 Drill hole diameter do [mm] 6 8 8 10 Mean ultimate loads Nu,m and Vu,m [kN] Tensile 0° Nu,m [kN] gvz – – 14.3* 19.2 [kN] fvz – – 15.5* – [kN] A4 10.6* – 16.4 20.5 Shear 90° Vu,m [kN] gvz – – 11.3* 16.6* [kN] fvz – – 12.3* – [kN] A4 9.0* – 15.1* 24.0* Recommended loads Nrec and Vrec [kN] Tensile 0° Nrec [kN] gvz – 2.5 4.4 4.7 [kN] fvz – – 4.8 – [kN] A4 3.3 – 4.4 4.7 Shear 90° Vrec [kN] gvz – 3.2 5.3 5.8 [kN] fvz – – 6.7 – [kN] A4 4.3 – 5.3 5.8 Recommended bending moment Mrec [Nm] Mrec [Nm] gvz – 10.5 10.5 21.4 [Nm] fvz – – 13.7 – [Nm] A4 6.5 14.7 14.7 29.7 Component dimensions, minimum axial spacings and edge distances Min. axial spacing1) smin [mm] gvz – 35 50 45 fvz – – 50 – A4 40 – 50 50 Min. edge distance1) cmin [mm] gvz – 35 50 55 fvz – – 50 – A4 35 – 35 60 Min. structural component 100 100 100 100 hmin [mm] thickness 7.5 15 15 30 Required torque Tinst [Nm] * not included in approval notice. 47.1 70.1 47.1 – 52.8 – 33.4* 71.4* 33.4* – 56.5* – FBN – with large washer according to DIN 440, outside diameter approx. 3.5 x d do Imprint on head Art. No. td Min. drill-hole depth for through fixing mm hef Min. Anchorage depth mm l tfix Max. fixing thickness mm M 10.9 10.9 15.2 20.9 10.0 – 11.6 – 10.9 9.2 13.4 – 12.9 16.9 16.9 36.5 12.9 – 16.9 – 12.9 16.9 16.9 – Type Drill mm Overall length mm Thread x length Qty. per pack FBN 12x180 GS FBN 12x200 GS FBN 12x220 GS FBN 12x240 GS FBN 12x260 GS FBN 12x300 GS FBN 12x350 GS FBN 16x220 GS FBN 16x260 GS FBN 16x280 GS FBN 16x320 GS FBN 16x370 GS FBN 16x420 GS 1) N P R S T V W P S T V W X 45160 45161 45162 45163 45164 45165 45166 45167 45168 45169 45170 45171 45172 12 12 12 12 12 12 12 16 16 16 16 16 16 170 190 210 230 250 290 340 208 248 268 308 358 408 70/50 70/50 70/50 70/50 70/50 70/50 70/50 84/64 84/64 84/64 84/64 84/64 84/64 180 200 220 240 260 300 350 220 260 280 320 370 420 80/100 100/120 120/140 140/160 160/180 200/220 250/270 100/120 140/160 160/180 200/220 250/270 300/320 M12 x 137 M12 x 157 M12 x 177 M12 x 100 M12 x 100 M12 x 100 M12 x 100 M16 x 166 M16 x 100 M16 x 100 M16 x 100 M16 x 100 M16 x 100 20 20 20 10 10 10 10 10 10 10 10 10 10 21.4 40.5 40.5 96.0 96.0 194.6 29.1 – 40.5 – 96.0 – 29.7 46.9 46.9 114.3 114.3 – 55 55 60 65 65 55 100 30 100 – 65 100 – 70 100 50 75 130 80 90 100 75 140 50 140 – 90 100 – 80 130 100 90 85 90 105 80 80 170 100 170 – – 150 – – 200 200 * steel failure 1) For min. axial spacing and min. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for: concrete compressive strength fc,200 = 30 N/mm2 no edge or spacing influences. Recommended loads: material safety factors γM and safety factor for load γL = 1.4 are included. Material safety factor γM depends on type of anchor. The conditions of application differ from those given in the European Technical Approval. For further detailed information about European Technical Approvals please contact fischer technical service department. 2) Min. embedment depth for maximum permitted load/the minimum embedment depth can be reduced to . . . for the extended effective length and reduced load. Embedment length for maximum permissible load/embedment length for reduced load. 33 seating. metal constructions. safe expansion. stock pens. No. 1 fischerbolt FA For fixing: Railings. 1 Description ½ For through fixing. drill-hole depth for through fixing mm hv Min. supports. metal profiles. m [kN] (mean values) and recommended loads Frec [kN] for a single anchor in non-cracked concrete Anchor type/thread Fu. m Frec Axial spacing Edge distance Min. hand rails. with hexagon domed nut do td Min. ½ Highest reliability. anchorage depth mm l da Max. gratings.HIGH PERFORMANCE STEEL ANCHORS fischer Anchor bolt FA The economical through bolt thats re-usable ideal for stadium seating Suitability Suitable for: concrete ≥ B15 and dense natural stone. component thickness B25 B25 (cm) (cm) (cm) FA 8 1280 250 16 8 15 FA 10 1540 350 24 10 15 FA 12 2030 450 26 13 20 FA 14 2540 600 40 15 20 Installation diagram 34 . Drill Æ mm Fixing length mm Torque Nm Width across nut Qty per FA 8/15 FA 8/25 FA 10/15 FA 10/50 FA 12/15 FA 12/50 FA 14/20 FA 14/50 ( 8 x 70) ( 8 x 85) (10 x 85) (10 x 120) (12 x 100) (12 x 135) (14 x 115) (14 x 145) 50200 50207 50201 50208 50202 50212 50203 50214 8 8 10 10 12 12 14 14 75 90 90 120 100 135 115 145 50 50 60 60 70 70 80 80 65 80 75 110 85 120 100 130 15 25 15 50 15 50 20 50 10 10 20 20 35 35 50 50 13 13 17 17 19 19 22 22 25 25 25 25 20 20 10 20 Ultimate loads Fu. ½ Torque controlled. fixing thickness mm Mc SW Type pack Art. machines. consoles. calibrated hold and depth in all compact materials ½ The reduced diameter and practical installation make it ideal for a quick. ½ Demountable fixing leaving a flush surface ½ Domed nut for neat appearance ½ Red knurled collar prevents turning in hole on installation ½ The expansion sleeve guarantees an even. secure job FA – zinc plated and passivated. For your notes 35 . thereby ensuring that the load is safely supported by a perfect form fit. NEW 4 5 6 Suitability Suitable for: Concrete ≥ B15 and masonry building materials.1-1718 Concrete screw FBS 8 + 10 Concrete screw FBS 10 A4 Concrete screw FBS 5 + 6 Fire resistance classification F 90/120 Installation diagram 36 . ventilation ducts. ½ Minimum edge and axial distances through absence of expansion pressure. suspended ceilings. pipework.1-1717 Z-21. shelf feet. ½ High permissible loads through safe form fit.HIGH PERFORMANCE STEEL ANCHORS fischer Concrete screw FBS Safe form fit through special thread. The diameter of the hole and the thread of the screw are adapted to one another so that the special thread of the screw cuts into the concrete. 1 2 3 Panhead (P) Countersunk head (SK) Hexagon with integrated washer (US) Hexagon (S) External thread (M8) Internal thread (M8/M10) 1 4 2 5 3 6 Description fischer concrete screws have a specially hardened thread.1-1716 Z-21. The lower turns of the thread also have teeth. Also suitable for temporary fastenings such as wall shuttering. metal profiles. ½ Fully detachable screw attachment. The teeth allow the thread to cut into the concrete. ½ Variable application through different head shapes. Approvals Z-21. For fixing of: Installation rails. facade sub-structures. wood sub-structures. Advantages ½ Fast installation by simply screwing the screw into the hole in the concrete. The thread turns creating a fine undercut. thereby reducing the amount of energy required to insert the screw into its position. 3 0° 90° Nu.4 54.6 7.0 – 40.6 7. 1) For min.2 – – – 3.4 54.8 – – 8. Drill mm Screw outer mm Screw length mm Drive Qty.4 1.5 – 7.0 16. fixing thickness mm L= hnom + t fix Installation example Type Art.4 heff ho hnom do [mm] [mm] [mm] [mm] FBS 8 50 85 75 8 FBS 10 60 95 85 10 FBS 5* 55 60 – 5 Cracked concrete FBS 6* 55 60 – 6 FBS 8 50 85 75 8 FBS 10 60 95 85 10 * For the fixing of lightweight suspended ceiling constructions only. Recommended loads: material safety factors γM and safety factor for load γL = 1.0 – 19.4 are included.4 – 4. per pack zinc plated FBS 5/5 P FBS 6/5 SK FBS 6/5 P FBS 6/25 P FBS 6 M8 FBS 8/5 US FBS 8/25 US FBS 8/15 S FBS 10/5 S FBS 10/15 S FBS 10/25 S 66774 66935 66939 66948 66949 66956 66957 66958 67062 67063 67168 5 6 6 6 6 6 8 8 8 10 10 10 10 7 8 8 8 – – 12 12 12 14 14 14 14 6.m and Vu. Material safety factor γM depends on type of anchor.0 – 29.8 0° 90° Nrec Vrec [kN] [kN] [kN] [kN] gvz A4 gvz A4 5.2 – 29.5 10. minimum axial spacings and edge distances Min.5 12.6 10. 37 .4 – 6.5 12.6 7.6 6. For further detailed information about German approval please contact fischer technical service department.m [kN] [kN] [kN] [kN] gvz A4 gvz A4 21.0 36. The conditions of application differ from those given in the German approval.3 – – – 0.m Vu.HIGH PERFORMANCE STEEL ANCHORS fischer Concrete screw FBS Technical data do df Drillhole in object mm ds td Min.1 13. axial spacing and min.6 – 16.m [kN] Tensile Shear Recommended loads Nrec and Vrec [kN] Tensile Shear Recommended bending moment Mrec [Nm] Mrec Component dimensions.6 7.6 12.200 = 30 N/mm2 no edge or spacing influences. edge distance1) Min.0 4.5 10.6 0.0 48.0 12.5 65 65 65 85 60 60 90 110 100 100 110 120 105 55 55 55 55 55 55 75 75 75 85 85 85 85 5 5 5 25 – – 5 25 15 5 15 25 10 60 60 60 80 55 55 80 100 90 90 100 110 95 T30 T30 T30 T30 SW10 SW13 100 100 100 100 100 100 FBS 6 M8/M10I 66950 T40/SW13 100 T40/SW13 100 SW16 SW18 SW18 SW18 SW17 100 50 50 50 50 A4 stainless steel FBS 10/10 S A4 67169 Mean ultimate loads and recommended loads for single anchors of fischer concrete screw FBS with large axial spacing and edge distance Non-cracked concrete Anchor size Effective anchorage depth Drill hole depth Screw-in depth Drill hole diameter Mean ultimate loads Nu.0 36. No.5 12.2 – – – 10. axial spacing1) Min. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for: concrete compressive strength fc.3 – 7.0 – 40.4 48.5 7.6 – 26. drill-hole depth for pushthrough installation mm hnom Min.4 26.1 13. Screwin depth mm tfix Max. structural component thickness smin cmin hmin [mm] [mm] [mm] 50 60 120 60 65 130 50 100 110 50 100 110 50 60 120 60 65 130 [Nm] [Nm] gvz A4 19.5 12.8 – – – 2. the geometry of the expansion sleeve and the cone has been improved and the combined effect of these two functional elements optimised. The assembly object braces tightly against the building material. handrails. The FSA is available in 2 versions: ½ FSA-S with hexagon screw and cone nut 2 Picture for illustration purposes only Advantages ½ The simple design and construction result in an excellent cost-performance ratio. ½ The crescent-shaped punch-outs enable the sleeve to neatly slide together on the axis when bridging hollow layers. gratings. Suitability Suitable for: Concrete ≥ B15 and natural stone with dense structure. thus providing optimum safety and reliability at the high level you expect of fischer. ½ The setting depth mark allows verification of the correct installation any time. 1 Description The fischer Sleeve anchor FSA is a torque controlled expanding steel anchor for all through fixings for light and medium loads. machines.HIGH PERFORMANCE STEEL ANCHORS fischer Sleeve anchor FSA The economical through bolt for all applications not requiring Approvals. This guarantees full expansion in all cases. consoles. ½ The setting head at the runout of the conical bolt prevent damage to the thread. an easy thread travel is always ensured. For fixing of: Railings. In the case of de-mounting. metal profiles etc. metal constructions. supports. ½ The computer optimised anchor cone and the suitably adjusted expansion sleeve result in a safe expansion. l ∅ do td hv da MD M Installation diagram 38 . Unlike ordinary sleeve anchors. 1 2 Sleeve anchor FSA-S Sleeve anchor FSA Material: zinc plated and passivated steel. 5 M 6 M 6 M 6 M 8 M 8 M 8 M10 M10 M10 M10 M12 M12 M12 M16 M16 M16 8 8 8 10 10 10 13 13 13 17 17 17 17 19 19 19 24 24 24 100 100 100 100 100 100 50 50 50 25 25 20 20 20 10 10 10 5 5 FSA-A2 – Stainless Steel A2. edge distance1) cmin [mm] 50 Min. Drill mm Fixing length mm Thread Width across nut Qty.2 Component dimensions.5 8.7 100 60 100 40 Effective anchorage depth heff [mm] 35 Drill hole depth ho [mm] 50 Drill hole diameter do [mm] 8 Mean ultimate loads Nu. drill-hole depth for through fixing mm hv Min. Drill mm Fixing length mm Thread Width across nut FSA 20/20 FSA 20/50 FSA 20/95 FSA 8/45 A2 FSA 8/65 A2 FSA 10/50 A2 FSA 10/70 A2 60250 60251 60252 60253 8 8 10 10 10 10 12 12 12 12 60 80 65 85 115 135 80 100 120 140 25 30 30 35 35 35 35 40 40 40 45 65 50 70 100 120 60 80 100 120 10 25 10 25 55 75 10 25 45 65 M 6 M 6 M 8 M 8 M 8 M 8 M10 M10 M10 M10 10 10 13 13 13 13 17 17 17 17 100 50 50 50 50 50 25 25 20 20 FSA 10/100 A2 60254 FSA 10/120 A2 60255 FSA 12/60 A2 FSA 12/80 A2 60256 60257 Installation examples FSA 12/100 A2 60258 FSA 12/120 A2 60259 Mean ultimate loads and recommended loads for single anchors of fischer Sleeve anchor FSA with large axial spacing and edge distance Non-cracked concrete Anchor size FSA 8/. No. with hexagon screw and cone nut do td Min. per pack Type Art. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for: concrete compressive strength fc. axial spacing and min. No. Recommended loads: material safety factors γM and safety factor for load γL = 1. structural comp. M6 FSA 10/.8 Shear 90° Vrec [kN] gvz 5.2* Recommended loads Nrec and Vrec [kN] Tensile 0° Nrec [kN] gvz 2.0 Shear 90° Vu. drill-hole depth for through fixing mm hv Min. fixing thickness mm M SW FSA – zinc-plated and passivated steel.7 18. minimum axial spacings and edge distances 1) Min..2 12. with conical bolt and hexagon nut do td Min. fixing thickness mm M SW Type Art.1 4.9 80 60 80 25 FSA 12.5 M 4. per pack FSA 8/15 S FSA 8/40 S FSA 8/65 S FSA 10/10 S FSA 10/35 S FSA 10/60 S FSA 12/10 S FSA 12/25 S FSA 12/50 S 68520 68521 68522 68523 68524 68525 68526 68527 68528 8 8 8 10 10 10 12 12 12 65 90 115 65 90 115 75 90 115 35 35 35 40 40 40 50 50 50 69 94 119 70 95 120 81 96 121 15 40 65 10 35 60 10 25 50 M 6 M 6 M 6 M 8 M 8 M 8 M10 M10 M10 10 10 10 13 13 13 17 17 17 50 50 50 20 20 20 20 20 20 FSA 6/5 FSA 6/8 FSA 6/25 FSA 8/8 FSA 8/30 FSA 8/55 FSA 10/10 FSA 10/35 FSA 10/60 FSA 12/12 FSA 12/20 FSA 12/50 FSA 12/75 FSA 16/12 60168 60156 60157 60158 60150 60159 60160 60151 60152 60161 60153 60154 60162 60163 60155 60164 60165 60166 60167 6 6 6 8 8 8 10 10 10 12 12 12 12 16 16 16 20 20 20 35 48 68 57 81 107 63 90 115 73 85 115 140 84 128 162 107 139 183 20 30 33 34 36 37 38 40 40 46 50 50 50 52 58 62 62 64 63 25 38 58 42 66 92 48 75 100 58 70 100 125 64 108 142 82 114 158 5 8 25 8 30 55 10 35 60 12 20 50 75 12 50 80 20 50 95 M 4. anchorage depth mm l da Max. fixing thickness mm M SW FSA 16/50 FSA 16/80 Qty. For detailed design method please contact fischer technical service department. anchorage depth mm l da Max.m [kN] gvz 13. No.7 6.m [kN] Tensile 0° Nu. with conical bolt and hexagon nut do td Min.7 3. M 10 50 65 12 21.HIGH PERFORMANCE STEEL ANCHORS fischer Sleeve anchor FSA Technical data Picture for illustration purposes only FSA-S – zinc-plated and passivated steel. 39 . per pack Type Art. drill-hole depth for through fixing mm hv Min.4 are included..7 25. axial spacing smin [mm] 70 Min.m [kN] gvz 12.1 Recommended bending moment Mrec [Nm] Mrec [Nm] gvz 5.5 26. M8 40 55 10 14. thickness hmin [mm] 70 Required torque Tinst [Nm] 10 * steel failure 1) For min.200 = 30 N/mm2 no edge or spacing influences. anchorage depth mm l da Max.5 M 4. Drill mm Fixing length mm Thread Width across nut Qty. Material safety factor γM depends on type of anchor..m and Vu. If the anchor encounters a cavity during installation. it can be located down to a minimum distance of 50 mm from the prestressing steel. Unlike other competing products. 1 Hollow-ceiling anchor FHY Material: zinc plated steel and A4 stainless steel 1 Description The fischer Hollow-ceiling anchor FHY has been developed specially for fastenings in hollow-ceiling slabs of prestressed concrete. In this way. Instead. concrete ≥ B55. e. When the bolt or the nut is tightened a tapered element is pulled into the sleeve. The Hollow-ceiling anchor FHY is installed flush with the concrete surface. creating a friction fit. the expansion of the sleeve forms a Y shape. the FHY presses against the sides of the hole.1-1711 Approval is valid for zinc plated steel. The fischer Hollow-ceiling anchor FHY offers considerable scope in the location of attachment points. suspended ceilings. Suitability Suitable for: Hollow-ceiling slabs of prestressed concrete. it does not have to be located at the centre of the cavity axis. cross beams. Fire resistance classification Tinst F 120 Installation diagram 40 tfix hef . pipes and ventilation ducts. which is often very difficult to define. It is designed for use with standard bolts or threaded rods with metric threads from M6 to M10. safety engineering. For fixing of: All types of anchoring. which presses this outwards. cable trays. The holding power is now the result of a combination of expansion pressure and form-fit.HIGH PERFORMANCE STEEL ANCHORS fischer Hollow-ceiling anchor FHY Specially for fixings in hollow-ceiling slabs.g. Installation advice How to determine the length of the screw ls: length of the fischer Hollow-ceiling anchor FHY (+ thickness of the building component da (= length of the screw (+ additional thickness of nut and washer with threaded rods) do ls Approvals Z-21. anchorage depth mm l Fixing length mm Screw-in depth min. The permissible load for the most highly stressed fixing must not exceed the values stated for the single fixing.35 0.7 kN 0. The fixing may also be used as multiple fastening for anchoring lightweight ceiling coverings and underceilings to DIN 18168 on hollow-slab ceilings of prestressed concrete.04) 39 + tfix 62 + tfix 10 7 6.8 21. the shaft length must be ≤ t .0 1.4401) do Drill mm h1* Min. anchorage depth mm l Fixing length mm Screw-in depth min.2 = Safe working bending moment Grade 4. 4) Only threaded rods marked in accordance with the approval may be used. Fixing type Web thickness FHY M 6 du mm ≥ 25 < 30 h1 ≥ mm mm kN 0.6 kN 0.4 2. per. per.* mm mm Qty. The linear value at s1.8 150 100 300 kN 0.0 1.25 2.9 0.25 2.0 kN/m2. max.7 1.2 < s1. drillhole depth mm hef 1) Min.35 mm 70 80 100 70 80 100 mm 150 mm 100 Nm Nm Nm mm mm Nm mm – 4. may be assumed to be twice the permissible load for the single fixing.7 1. No. drillhole depth mm hef 1) Min.8 4.7 0.8 1.2 ≥ Min.2 the permissible load may be interpolated linearly. fix 41 .74) 17.44) 7. No.2 times the web width.8 Length of hexagon-head min ls ≥ screw5) Length of threaded bolt min lB ≥ Installation torque TInst Through-hole in the component df ≤ to be attached 1) ≥ 30 ≥ 40 ≥ 25 < 40 < 30 50 10 0. F with c ≥ ccr1.8 ≥ 30 ≥ 40 ≥ 30 ≥ 40 < 40 < 40 60 65 12 16 2.2 for the pair of fixings with tensile load applied. When external loads are suspended from the prestressed-concrete hollow-slab ceilings.35 1.0 2.8 80 4. this reduction is not necessary.44) 34.6 0. to DIN 18168.35 mm mm mm FHY M 8 FHY M 10 Drill hole depth Drill hole diameter Single fixing Perm. observe the approval Z-21.0 3. For fastening lightweight ceiling coverings and underceilings.2 Axial spacing2) ccr1. the width of whose cavities is not more than 4. pack Type Art. shear and diagonal load at any angle in hollow-slab floors of prestressed concrete of strength class ≥ B55 or ≥ C50/60. For pairs of fixings with min axial distances of smin1.2 ≥ Edge distance ccr1.2 ≥ Pairs of fixings3) Perm.3 100 12.35 0.8 2.* mm mm Qty.2 Perm.9 0. axial spacing smin1. Thread FHY M 6 A4 FHY M 8 A4 FHY M 10 A4 30139 30147 30151 10 12 16 50 60 65 30 35 40 37 43 52 M 6 M 8 M 10 37 43 52 45 55 60 50 25 20 * in solid materials Recommended loads1) fixing parameters and component dimensions for tension.2 1.8 Grade 5.24) 54 + tfix 77 + tfix 20 12 The anchorage of the Cavity Fixing FHY is permissible only in hollow-slab ceilings of prestressed concrete. max.0 1.4 10.14) 45 + tfix 68 + tfix 10 9 2. 2) For edge distances c min < c ccr the permissible loads may be determined by linear interpolation. Thread FHY M 6 FHY M 8 FHY M 10 30138 30146 30148 10 12 16 50 60 65 30 35 40 37 43 52 M 6 M 8 M 10 37 43 52 45 55 60 50 25 20 FHY – A4 stainless steel (Material: 1.2 = scr1.2 ≥ Min. edge distance2) cmin1. 5) With hexagon bolts with shaft to DIN EN 24014. F 2) with c ≥ ccr1.2 ≥ Axial spacing scr1.35 1.HIGH PERFORMANCE STEEL ANCHORS fischer Hollow-ceiling anchor FHY Technical data Installation examples FHY – zinc plated steel do Drill mm h1* Min. When dimensioning.7 0. and for statically similar anchorages up to 1. pack Type Art. edge distance cmin1. 3) The permissible load applies for a pair of fixings.4 2.2 < scr1. the shearing loadbearing capacity must be reduced. F with c = cmin Min.1-1711 in its entirety.6 Grade 5. F 2) with c = cmin1.2 Perm. For fixing of: Installation rails. ½ Zinc plated and passivated for corrosion protection. ½ Check load bearing capacity values in the table. pipework.eye bolt type Description The segmented malleable iron expansion shield is assembled ready for use with bolts or threaded rods of the appropriate diameter. suspended ceilings. ½ Make sure the drilled hole is dust free.hook bolt type GM P wallbolt . For the best results with the GM anchor remember to: ½ Choose the most suitable accessory. ½ Function . ½ Choose the right sized anchor in relation to load type. ½ Four piece malleable shield for even load spread. 1 2 3 4 5 Installation diagram 42 . ½ Unique metal spring clip for retaining the segments and the wedge.shield only GM H wallbolt . ventilation ducts.HIGH PERFORMANCE STEEL ANCHORS fischer Wallbolt GM The economical heavy-duty anchor Suitability Suitable for: Concrete ≥ B15 and natural stone with dense structure.torque controlled friction locking expansion. Also suitable for temporary fastenings such as wall shuttering 1 2 3 4 5 GM S wallbolt .projecting bolt type GM L wallbolt .loose bolt type GM E wallbolt . ½ Traditional fixing method with wide user acceptance. shelf feet. metal profiles. axial spacing a 140 170 Crit.40 3. anchorage depth mm Type Art.40 315 200 170 105 175 GM 20 20.00 3. edge dist.5 10. drill-hole depth mm hv Min. per box do td Min. edge distance ar 40 105 Min. drill-hole depth mm hv Min. anchorage depth mm Fixing Thickness mm min max GM S – zinc plated and passivated do td Min.40 2. 8. No. per box GM 6/10 L GM 6/25 L GM 6/40 L GM 8/10 L GM 8/25 L GM 8/40 L GM 10/10 L GM 10/25 L GM 10/50 L GM 10/75 L GM 12/10 L GM 12/25 L GM 12/50 L GM 12/75 L GM 16/15 L GM 16/30 L GM 16/60 L GM 20/60 L GM 20/100 L GM 24/100 L GM 24/150 L 58001 58002 58003 58004 58005 58006 58007 58008 58009 58010 58011 58012 58013 58014 58015 58016 58017 58018 58019 58021 58022 12 12 12 15 15 15 18 18 18 18 22 22 22 22 29 29 29 36 36 42 42 60 60 60 70 70 70 80 80 80 80 100 100 100 100 130 130 130 170 170 210 210 47 47 47 50 50 50 60 60 60 60 75 75 75 75 102 102 102 135 135 165 165 6 6 6 8 8 8 10 10 10 10 12 12 12 12 16 16 16 20 20 24 24 0 10 0 25 0 40 0 10 0 25 0 40 0 10 0 25 0 50 25 75 0 10 0 25 0 50 25 75 0 15 0 30 25 60 20 60 60 100 20 100 60 150 10 10 10 25 25 25 40 40 40 40 75 75 75 75 180 180 180 345 345 345 345 50 50 50 50 50 50 50 50 50 25 25 25 25 25 10 10 10 10 10 10 10 GM 6 S GM 8 S GM 10 S GM 12 S GM 16 S GM 20 S GM 24 S 58060 58061 58062 58063 58064 58065 58066 12 15 18 22 29 36 42 60 70 80 100 130 170 210 47 50 60 75 102 135 165 6 8 10 12 16 20 24 10 25 40 75 180 345 345 50 50 25 20 10 5 5 GM E – zinc plated and passivated do td Min.kN Anchor type Bolts cl.fc = 25 Nm/mm2 . anchorage depth mm Type Art. 80 80 Min. drill-hole depth mm hv Min.65 4. 50 50 Min.5 21.30 GM 10 5.40 8. struct.90 200 120 100 65 100 GM 12 8. No. Drill Ø mm GM 6/10 P GM 6/25 P GM 6/60 P GM 8/10 P GM 8/25 P GM 8/60 P GM 10/15 P GM 10/30 P GM 10/60 P GM 12/15 P GM 12/35 P GM 12/75 P GM 16/15 P GM 16/35 P GM 16/75 P GM 20/15 P GM 20/30 P GM 20/100 P GM 24/75 P GM 24/120 P 58030 58031 58032 58033 58034 58035 58036 58037 58038 58039 58040 58041 58042 58043 58044 58045 58046 58047 58048 58049 12 12 12 15 15 15 18 18 18 22 22 22 29 29 29 36 36 36 42 42 60 60 60 70 70 70 80 80 80 100 100 100 130 130 130 170 170 170 210 210 47 47 47 50 50 50 60 60 60 75 75 75 102 102 102 135 135 135 165 165 6 6 6 8 8 8 10 10 10 12 12 12 16 16 16 20 20 20 24 24 0 10 0 25 0 60 0 10 0 25 0 60 0 15 0 30 0 60 0 15 0 35 0 75 0 15 0 35 0 75 0 15 0 30 0 100 0 30 0 100 10 10 10 25 25 25 40 40 40 75 75 75 180 180 180 345 345 345 345 345 50 50 50 50 50 50 50 25 25 20 20 20 10 10 10 5 5 5 5 5 Type Art.90 1.5 10 25 40 75 100 50 50 25 15 10 Recommended loads [kN] Loads in concrete cl.90 GM 8 4.a min.5 11 12.5 15. No.5 13 15. per box GM 6 H GM 8 H GM 10 H GM 12 H GM 16 H 58055 58056 58057 58058 58059 12 14 16 20 29 60 70 80 100 130 47 50 60 75 102 6 8 10 12 16 7. per box Type Art. drill-hole depth mm hv Min. anchorage depth mm GM H – zinc plated and passivated Bolt Ø mm Fixing Thickness mm min max Torque Nm Qty. Drill Ø mm Bolt Ø mm Eye Ø mm Torque Nm Qty.8 Eyebolt Hook GM 6 4. anchorage depth mm Type Art. drill-hole depth mm hv Min. per box GM 6 E GM 8 E GM 10 E GM 12 E GM 16 E 58050 58051 58052 58053 58054 12 15 18 22 29 60 70 80 100 130 47 50 60 75 102 6 8 10 12 16 10.5 25 10 25 40 75 180 50 50 25 15 10 GM P – zinc plated and passivated do td Min.20 0.90 5.65 13.HIGH PERFORMANCE STEEL ANCHORS fischer Wallbolt GM Technical data Technical data GM L – zinc plated and passivated do td Min.65 1. axial sp. Drill Ø mm Bolt Ø mm Hook mm Torque Nm Qty. Drill Ø mm Bolt Ø mm Torque Nm Qty.armin. No. No. thickness t 100 100 43 .90 400 260 230 140 230 Critical edge distance and critical spacing [mm] Crit. Drill Ø mm Bolt Ø mm Torque Nm Qty.30 250 150 125 80 125 GM 16 13. HIGH PERFORMANCE STEEL ANCHORS fischer Wallbolt FWB The economical heavy-duty anchor Suitability Suitable for: Concrete ≥ B15 and natural stone with dense structure. pipework. 1 2 Function . ventilation ducts.shield only FWB L wallbolt . The versatile heavy-duty fixing ! 4 3 5 Installation instructions Determination of the screw length l s: length of the fischer Heavy-duty anchor FWB + thickness of the building component da = length of the screw (in the case of threaded bolts additionally include + thickness of washer and nut) Installation diagram 44 . For fixing of: Installation rails.torque controlled friction locking expansion. suspended ceilings. Traditional fixing method with wide user acceptance.projecting bolt type FWB H wallbolt .eye bolt type Description The segmented steel expander shield is assembled ready for use with bolts or threaded rods of the appropriate diameter. metal profiles.loose bolt type FWB P wallbolt . Zinc plated and passivated for corrosive protection. Also suitable for temporary fixings such as wall shuttering 1 2 3 4 5 FWB S wallbolt . shelf feet.hook bolt type FWB E wallbolt . Three piece shield for even load spread. drill-hole depth mm hv Min. Drill Ø mm Bolt Ø mm Hook mm Torque Nm Qty. Drill Ø mm Torque Nm Drill Ø mm Bolt Ø mm Torque Nm Qty. per box td Min. per box FWB 6 E FWB 8 E FWB 10 E FWB 12 E FWB 16 E 58193 58194 58195 58196 58197 12 14 16 20 25 50 55 65 85 130 45 50 60 75 115 6 8 10 12 16 10 12 14 17 23 10 25 40 75 180 50 50 25 25 10 FWB 20/100 L 58174 FWB P – zinc plated and passivated do td Min. anchorage depth mm Fixing Thickness mm min max FWB S – zinc plated and passivated do Bolt Ø mm Qty. per box FWB 6/10 L FWB 6/25 L FWB 6/40 L FWB 8/10 L FWB 8/25 L FWB 8/40 L FWB 10/10 L FWB 10/25 L FWB 10/50 L FWB 10/75 L FWB 12/10 L FWB 12/25 L FWB 12/40 L FWB 12/60 L FWB 16/15 L FWB 16/30 L FWB 16/60 L FWB 20/60 L 58156 58157 58158 58159 58160 58161 58162 58163 58164 58165 58166 58167 58168 58169 58170 58171 58172 58173 12 12 12 14 14 14 16 16 16 16 20 20 20 20 25 25 25 32 32 50 50 50 55 55 55 65 65 65 65 85 85 85 85 130 130 130 150 150 45 45 45 50 50 50 60 60 60 60 75 75 75 75 115 115 115 130 130 6 6 6 8 8 8 10 10 10 10 12 12 12 12 16 16 16 20 20 0 10 0 25 0 40 0 10 0 25 0 40 0 10 0 25 0 50 25 75 0 10 0 25 0 50 25 75 0 15 0 30 25 60 20 60 60 100 10 10 10 25 25 25 40 40 40 40 75 75 75 75 180 180 180 345 345 50 50 50 50 50 50 50 50 50 25 25 25 25 25 10 10 10 10 10 FWB 6 S FWB 8 S FWB 10 S FWB 12 S FWB 16 S FWB 20 S 58050 58051 58052 58053 58054 58055 12 14 16 20 25 32 50 55 65 85 130 150 45 50 60 75 115 130 6 8 10 12 16 20 10 25 40 75 180 345 50 50 50 25 10 10 FWB E – zinc plated and passivated do td Min. 01491 827920 FWB 20/100 P 58192 45 . drill-hole depth mm hv Min. anchorage depth mm Fixing Thickness mm min max FWB H – zinc plated and passivated do Bolt Ø mm Qty. No. No. drill-hole depth mm hv Min. Drill Ø mm Bolt Ø mm Eye Ø mm Torque Nm Qty. No. No. anchorage depth mm Type Art. anchorage depth mm Type Art. drill-hole depth mm hv Min. Drill Ø mm Torque Nm FWB 6/10 P FWB 6/25 P FWB 6/60 P FWB 8/10 P FWB 8/25 P FWB 8/60 P FWB 10/15 P FWB 10/30 P FWB 10/60 P FWB 12/15 P FWB 12/35 P FWB 12/75 P FWB 16/15 P FWB 16/35 P FWB 16/75 P FWB 20/15 P FWB 20/30 P 58175 58176 58177 58178 58179 58180 58181 58182 58183 58184 58185 58186 58187 58188 58189 58190 58191 12 12 12 14 14 14 16 16 16 20 20 20 25 25 25 32 32 32 50 50 50 55 55 55 65 65 65 85 85 85 130 130 130 150 150 150 45 45 45 50 50 50 60 60 60 75 75 75 115 115 115 130 130 130 6 6 6 8 8 8 10 10 10 12 12 12 16 16 16 20 20 20 0 10 0 25 0 60 0 10 0 25 0 60 0 15 0 30 0 60 0 15 0 35 0 75 0 15 0 35 0 75 0 15 0 30 0 100 10 10 10 25 25 25 40 40 40 75 75 75 180 180 180 345 345 345 50 50 50 50 50 25 50 25 25 25 25 25 10 10 10 10 10 10 Type Art. No. per box Type Art. per box FWB 6 H FWB 8 H FWB 10 H FWB 12 H 58198 58199 58200 58201 12 14 16 20 50 55 65 85 45 50 60 75 6 8 10 12 8 10 12 16 10 25 40 75 50 50 25 25 Recommended loads [kN] For information relating to loads please contact the fischer technical department.HIGH PERFORMANCE STEEL ANCHORS fischer Wallbolt FWB Technical data Technical data FWB L – zinc plated and passivated do td Min. anchorage depth mm Type Art. td Min. drill-hole depth mm hv Min. M e ls EA M 8 x 40 M 10. suspended ceilings.1-1619 t = hv Approved for the tension zone. gratings. ventilation pipes. sprinkler systems. threaded rods. ½ The cone must only be driven with the setting tool EAWH (narrow-end) into the anchor sleeve. heating. metal constructors and fitters Installation advice ½ It is essential to adhere to the drill-hole depth and drill diameter. The setting method of ’tapping in’ and price/performance ratio have made the EA anchor a standard metal fixing most acoustics installers. etc. If the screw is too short: Thread load-bearing capacity too low. The screw length must be carefully determined: min. ½ The cone must be driven into the anchor sleeve until the tool collar lies on the anchor body. light suspended ceilings and ceiling covers. screw-in depth + thickness of the building component = screw length (with threaded bolt. da MD do Recognised for use with fixed water sprinkler systems from M8. made of zinc plated steel for metric threads M 6 to M 20.HIGH PERFORMANCE STEEL ANCHORS fischer Hammerset anchor EA The simple hammerset anchor with internal thread. A4 stainless steel. ventilation and sanitary equipment installers. It is universally easy to use and offers the following: ½ Economical fixing ½ Shallow drill-hole depth ½ displacement controlled impact expansion ½ favourable ratio of thread/drill-hole diameter The fischer Hammerset anchor EA forms a flush seal with the concrete surface and permits replacement of the mounted item without influencing the expansion force. assembly support. profiled steel.021 From thread M10 F 120 Installation diagram 46 . 1 Description The fischer Hammerset anchor EA is a compact internally threaded fixing for attachment assembly. 1 Hammerset anchor EA Material: zinc plated and passivated steel. include thickness of washer and nut) If the screw is too long: No tighteneing of the fixing is possible. diamond drilling devices (EA-D). Suitability Suitable for: Concrete ≥ B15 For fixing of: Flat steel. M 12 Fire resistance classification = da + e Dossier NPO. facades. pipelines. The sizes M 6 to M 16 are also available in stainless steel. Approvals Z-21. since screw reaches end of thread. 0 21. Thread EA M 61) EA M 8 EA M 8 x 40 EA M 10 EA M 12 EA M 16 EA M 20 60811 60812 60821 60813 60814 60816 60818 8 10 10 12 15 20 25 25 30 40 40 50 65 80 25 30 40 40 50 65 80 25 30 40 40 50 65 80 M 6 M 8 M 8 M 10 M 12 M 16 M 20 6 8 8 10 12 16 20 12 13 20 17 22 27 34 100 100 50 50 25 20 10 EA – A4 stainless steel (material: 1.6 11.0 16.4* M12 50 54 15 32. structural component thickness hmin [mm] 100 100 120 120 Required torque Tinst [Nm] 4 8 8 15 Recommended loads Nrec and Vrec [kN] Tensile 0° Nrec * steel failure. Recommended loads: material safety factors γM and safety factor for load γL = 1.4 107 170 220 200 60 M20 80 86 25 66.m [kN] Tensile 0° Shear 90° heff h1 = do Nu.9 – 4.3 3.1 12.1 24. 2) For min.3* – 13.8 0.5 12.HIGH PERFORMANCE STEEL ANCHORS fischer Hammerset anchor EA Technical data EA – zinc plated and passivated steel not suitable for diamond drilling devices and diamond saws do Drill mm t Min.0 14. No.8 – – – – 400 200 100 15 [kN] gvz 2.5 0.0 4.8 5.5 9. drill-hole depth mm hv Min.1 Component dimensions.0* 8.5 [kN] A4 2. The conditions of application differ from those given in the German approval.8* M8 x 40 40 43 10 16.5 6.2 3.0 6.8 0.m [mm] [mm] [mm] [kN] [kN] [kN] [kN] gvz A4 gvz A4 M6 25 27 8 10.2 8.4 71.7* 12.0 10.0 – 20. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for: concrete compressive strength fc.5 – – – – 400 100 100 3 Cracked concrete1) M8 x 40 40 43 10 – – – – 0.m Vu.2* – M10 40 44 12 18.5 10.2* 9.0 [Nm] A4 4. .8 0.8 – – – – 400 200 100 6 M12 50 54 15 – – – – 0.6 and A4-70 respectively.6 [kN] A4 3. minimum axial spacings and edge distances Min. anchorage depth mm l Fixing lenght mm M Screw-in depth min.8 4.0 – 4.0 – 50. Hammerset tools EAW H 6 EAW H 8 EAW H 8 x 40 EAW H 10 EAW H 12 EAW H 16 EAW H 20 60836 60837 60846 60838 60839 60841 60843 Fits EA M 6 Fits EA M 8 Fits EA M 8 x 40 Fits EA M 10 Fits EA M 12 Fits EA M 16 Fits EA M 20 1 1 1 1 1 1 1 Mean ultimate loads and recommended loads for single anchors of fischer Hammerset anchor EA with large axial spacing and edge distance Non-cracked concrete Anchor size Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu. axial spacing and min. .0 – 139 – 200 240 240 120 M6 25 27 8 – – – – 0.8 Recommended bending moment Mrec [Nm].9 12.4 are included.m and Vu.3 3. max.4401). axial spacing2) smin [mm] 70 80 100 100 Min. values apply to screws with a strength classification 5.1* 12. Material safety factor γM depends on type of anchor.8 28.5 0. not suitable for diamond drilling devices and diamond saws EA M 6 A41) EA M 8 A41) EA M 10 A4 EA M 12 A4 EA M 16 A4 60825 60826 60827 60828 60829 8 10 12 15 20 25 30 40 50 65 25 30 40 50 65 25 30 40 50 65 M 6 M 8 M 10 M 12 M 16 6 8 10 12 16 12 13 17 22 27 100 100 50 25 20 1) only part of the approval for light suspended ceilings .0 4.0 40. edge distance2) cmin [mm] 80 90 120 120 Min.4* 36.8* 9.8 – – – – 400 100 100 3 M10 40 44 12 – – – – 0.0 8.2* 22.5* 6.6 and A4-70 respectively Mrec [Nm] gvz 3.0 32.0 31.4 14.1* M8 30 33 10 14.5 Shear 90° Vrec [kN] gvz 2.9 4.200 = 30 N/mm2 no edge or spacing influences.3 – 10. values apply to screws with a strength classification 5. For further detailed information about German approval please contact fischer technical service department.5 – – – – 400 100 100 2 M8 30 33 10 – – – – 0.3 8. 47 . 1) For the fixing of lightweight suspended ceiling constructions only.1 42.1 140 150 150 35 M16 65 71 20 40.6 18. mm mm Quantity per pack Installation examples Type Art. 0 35. drill-hole depth for through fixing mm l . Description A drop-in anchor with rim so that the anchor always remains flush with the surface of the substrate. air-conditioning. with high retaining power. Drill mm depth for through fixing mm Fixing length mm Quantity per pack td Min. Anchoring base Concrete ≥ B 25 FDN 0. FDA-R 1 fischer Ceiling anchor FDN 1 Drop-in anchor with rim Ceiling anchor 1 1 Suitability Suitable for: Concrete ≥ B15 and dense natural stone plus hollow core slabs For fixing of: ideal for fastening with bolts or threaded rods for plumbing. The wedge shaped segments move over each other during insertion. Suitability Suitable for: Concrete ≥ B15 and dense natural stone For fixing of: ideal for fastening suspended ceiling wires or brackets. No. No. not dependant on hole depth. Drill mm FDA-R 6x25 FDA-R 8x30 FDA-R 10x30 62366 62378 62379 8 10 12 27 32 33 25 30 30 100 100 100 FDN 6/35 FDN 6/65 78644 78645 6 6 40 40 35. Description A ceiling anchor for rapid installation. wedging the nail in the hole.0 100 100 Mean ultimate loads in kN. Available in zinc plated. l Technical data do td Min. see page 47. heating and ventilation installations. The drill hole can now be overdepth without effecting the anchor Technical data do drill-hole Type Art. Mean ultimate loads in kN. Installation diagram 48 .HIGH PERFORMANCE STEEL ANCHORS HIGH PERFORMANCE STEEL ANCHORS fischer Drop-in Anchor with Rim. Fixing length mm Quantity per pack Type Art. Use 80% of EA loads. An appropriate safety coefficient must be allowed on these breaking values (see page 16).5 A rim for the accurate setting of the anchor flush to the surface. No screws required. l do Technical data h ef do td Min.55 60 FNH 8 40 50 8 1. fixing thickness mm tfix td Type Art. Suitability Suitable for: Concrete ≥ B25. drill-hole depth for through fixing mm hef Effect. Drill mm Fixing length mm Qty.4 are included. The object is held by its collar. Simple and timesaving. pressure-resistant natural stone. no. component thickness hef h1 do Nrec hmin [mm] [mm] [mm] [kN] [mm] FNH 5 20 30 5 0. Especially suitable for small items in building interiors. metal sheets and profiles. Installation diagram 49 . solid brick. the sleeve expands over its entire length in the hole. small items in building interiors 1 Nail Sleeve FNH 1 Installation example Description The FNH nail sleeve is a fast and economical fastening made of dacromet-coated sprung steel. anchorage depth mm l tfix Max. Material safety factor γM depends on type of anchor. lightweight building materials.20 50 FNH 6 30 40 6 0.HIGH PERFORMANCE STEEL ANCHORS fischer Nail Sleeve FNH The fast and simple fastening made of dacromet-coated sprung steel. For fixing of: Board sub-structures. When pushed through the object being installed.10 70 Recommended loads: material safety factors γM and safety factor for load γL = 1. per pack FNH 5/50 FNH 6/30 FNH 6/40 FNH 6/50 FNH 6/60 FNH 6/80 FNH 8/70 FNH 8/90 FNH 8/110 FNH 8/130 FNH 8/150 50192 19863 50638 77525 19864 19865 19866 19867 19868 19869 19870 5 6 6 6 6 6 8 8 8 8 8 30 40 50 60 70 90 80 100 120 140 160 20 30 30 30 30 30 40 40 40 40 40 50 30 40 50 60 80 70 90 110 130 150 30 – 10 20 30 50 30 50 70 90 110 100 100 100 100 100 100 100 50 50 50 50 Recommended loads for single anchors of fischer Nail sleeve FNH in kN Non-cracked concrete Fixing type Effective anchorage depth Drill hole depth Drill hole diameter Tensile ≥ B25 Min. ceiling insulation on light wood-wool boards. FNA with hook*: For suspending chains.1-606 Approved for the tension zone. giving a clean finish. cables or chains. metal profiles. punched tapes. FNA with M 6 + M 8 thread: For all demountable connections with metric thread. FNA with eye: For anchoring of hangers.HIGH PERFORMANCE STEEL ANCHORS fischer Nail anchor FNA For hammerset installation in concrete. The nail head can be effortlessly sunk into timber with one blow. suspended ceilings. ½ Low drilling expenditure. ½ All building site requirements are available. Stainless steel 1. chains.4529 . C-rails. For fixing of: Laths. 2 3 4 Advantages FNA with nail head: For battens and metal hangers. cable loops. Suitability Suitable for: Concrete ≥ B15.4529 Fire resistance classification see page 52-53 F 60/90/120 Installation diagram 50 . etc. two hammer blows are sufficient. ½ Building inspectorate approval for more safety. lamps. wire hangers. 1 Description The fischer Nail Anchor can be installed swiftly and smoothly. a real advantage for overhead work. wood substructures. ½ Easy tap-in assembly. cables. FNA for rail fixing: 5 Enables quick and easy installation of lightweight railing. battens. it covers a large surface area. Connection of threaded hanger rods is possible by means of extension couplers.see page 52/53. Approvals Z-21. rings or other closed parts. *Not an element of the building inspectorate approval. extension nuts with threaded rods. Longer useful lengths bridge non-load-bearing layers. Longer threaded portion enables bridging of non-load bearing layers such as plaster or insulation. only 6 mm diameter. ventilation pipes. 1 2 3 4 5 FNA FNA FNA FNA FNA with nail head with M6 + M8 thread with eye with hook for rail fixing Material: zinc plated and passivated steel. On metal parts. squared timber beams. A4 stainless steel and high corrosion resistant steel 1. fire partitions. light suspended ceilings and ceiling covers. punched tapes. 4 – 5.m Vu.1 Vrec [kN] gvz 1. structural comp. For detailed design method and design in accordance with German approval please contact fischer technical service department. No.0 60 50 100 4 FNA 6x40 M 8/5 40 55 6 – – – – 0. The condition of application differ from those given in the German approval. drill-hole depth for through fixing mm hv Min.9 Component dimensions. Steel A4 Art. anchorage depth mm l Fixing length mm da Max. Drill mm td Min. thickness hmin [mm] 100 Required torque Tinst [Nm] 4 * steel failure decisive 1) For the fixing of lightweight suspended ceiling constructions only. 2) Loads are not valid for the anchor type FNA with hook. with eye 10 mm FNA 6 x 30 OE 50922 6 45 30 64 50 with hook 10 mm FNA 6 x 30 H* 50921 6 45 30 64 50 * not included in building inspectorate approval for rail fixing FNA 6 x 40 S* 50947 6 60 40 55 5 50 * not included in building inspectorate approval Mean ultimate loads and recommended loads for single anchors of fischer Nail anchor FNA with large axial spacing and edge distance Non-cracked concrete Anchor size FNA 6x30 6x40 heff ho do Nu. 3) For min.0 1. Material safety factor γM depends on type of anchor. No.8 – 1.m [kN] Tensile2) Shear2) Recommended loads Nrec [kN] Tensile2) Shear2) Nrec [kN] gvz 2.8* – 2.6* 3. edge distance3) cmin [mm] 60 Min.1 – 120 80 100 4 Cracked concrete1) FNA 6x30 6x40 30 45 6 – – – – 0.0 6.5 0.0* – 9. Recommended loads: material safety factors γM and safety factor for load γL = 1.0* 5. edge distance the above described loads have to be reduced! (See “Technical Handbook” or design software “CC-Compufix”) All load values apply for: concrete compressive strength fc.m Vu.3 FNA 6x40 M 8/5 40 55 6 5.1 Nrec [kN] A4 2. fixing thickness mm M SW Qty. minimum axial spacings and edge distances Min.HIGH PERFORMANCE STEEL ANCHORS fischer Nail anchor FNA Technical data with nail head 15 mm do Steel gvz.5 1.m Nu. axial spacing3) smin [mm] 100 Min. Art.6 – 80 60 100 4 Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu.m [mm] [mm] [mm] [kN] [kN] [kN] [kN] gvz A4 gvz A4 30 45 6 5.4 are included. per pack Installation examples Type Width across Thread nut FNA 6 x 30/ 5 FNA 6 x 30/ 30 FNA 6 x 30/ 50 FNA 6 x 30/ 75 FNA 6 x 30/100 FNA 6 x 30/120 FNA 6 x 40/ 5 50938 50940 50942 50941 50943 50944 50936 77802* 77805* 6 6 6 6 6 6 6 50 75 95 115 150 170 60 30 30 30 30 30 30 40 45 71 91 111 145 165 55 5 30 50 75 100 120 5 100 50 50 50 50 50 50 * not included in building inspectorate approval with thread M 6 and M 8 FNA 6 x 30 M 6/5**50920 FNA 6 x 40 M 8/5**50951 77806* 6 6 50 55 30 40 52 55 5 5 M 6 10 M 8 13 100 50 * not included in building inspectorate approval – ** max. 51 . installation torque = 4 Nm.7 Vrec [kN] A4 2.200 = 30 N/mm2 no edge or spacing influences. axial spacing and min. fischer has the right fixing for your purpose. Approvals Z-21. pipelines. 1 2 3 4 5 6 7 fischer fischer fischer fischer fischer fischer fischer Zykon anchors FZA C Zykon hammerset anchors FZEA C Threaded rods RG M C Threaded rods FIS G C Highbond anchor FHB-A C Nail anchor FNA C Anchor Bolt FAZ . ½ In long years of research.0 1 Description ½ In atmospheres with high chloride. installations and suspended ceilings in indoor swimming pools. fischer now offers fixing elements of material 1.3-1707 Stainless steel 1.3-6. This guarantees you maximum flexibility. ½ These new fastening elements are made of high-alloy steel with material number 1. the FZEA Zykon Hammerset Anchor. Just contact our field engineers. even with special dimensions. sulphur-dioxide and humidity contents. steel structures and other mountings in bridge areas as well as in the chemical industry etc. For fixing of: Ventilation systems. the risk of corrosion is high due to the concentration of contaminants. 2 3 4 5 6 7 Advantages ½ Fast and safe anchoring is now possible in areas which were not previously included in the approval. ½ With the FZA Zykon Anchor.4529 Suitability Suitable for: Concrete ≥ B15. ½ For safe and durable fixing.4529 FHB FNA FAZ 52 . the FHB Highbond Anchor and the FNA Nail Anchor. cable trays in road tunnels.4529 which are suitable for use in the tension zone. interior-thread or synthetic-resin anchor. ½ In material approval Z-30. this highly corrosion-resistant steel has the highest resistance classification of IV. push-through.1-958 Z-21. Whether as bolt. ½ We manufacture job-specific products to your requirements.3-1615 ½ The right anchor for every fixing task. fischer now offers steel anchors which are able to withstand especially corrosive environmental conditions. FZA FZEA R + ETA option 8 Z-21.HIGH PERFORMANCE STEEL ANCHORS Anchors made of highly corrosion-resistant steel Material 1.C from version 5. fischer has accumulated an unequalled expertise in this field which we are happy to pass on to our customers.4529. The various areas of application are regulated in the approval thereby allowing maximum planning safety even in critical cases. fixing thickness mm Fits resin capsule SW (Width across) hexagon nut Qty. Drill mm Effect. Prices. Nail anchor FNA With nail head 15 mm do with thread M 6 and M 8 td Min. Prices. per pack Installation examples FZEA 10 x 40 M 8 C* FZEA 12 x 40 M 10 C* FZEA 14 x 40 M 12 C* 96236 96237 96238 10 12 14 40 40 40 M 8 M 10 M 12 11 13 15 17 19 21 100 100 50 * Article available from stock. pack * Article available from stock.4529 See page 21 “Tools”. anchorage depth mm da Fixing thickness mm M SW Thread Hexagon nut Required resin Qty. per set FHB-A 10 x 60/10 C FHB-A 10 x 60/60 C FHB-A 12 x 80/10 C FHB-A 12 x 80/60 C FHB-A 12 x 100/25 C FHB-A 12 x 100/60 C FHB-A 16 x 125/30 C FHB-A 16 x 125/60 C FHB-A 20 x 170/50 C FHB-A 24 x 220/50 C 62401 62402 62403 62404 62405 62406 62408 62407 62409 62418 12 12 14 14 14 14 18 18 24 28 65 65 85 85 105 105 130 130 175 225 60 60 80 80 100 100 125 125 170 220 10 60 10 60 25 60 30 60 50 50 10 10 12 12 12 12 16 16 20 24 17 17 19 19 19 19 24 24 30 36 * * * * * * * * * * 10 10 10 10 10 10 10 10 10 5 FZA 10 x 40 M 6/10 C* FZA 10 x 40 M 6/35 C FZA 12 x 40 M 8/15 C FZA 14 x 40 M 10/25 C FZA 12 x 50 M 8/15 C* FZA 12 x 50 M 8/50 C FZA 14 x 60 M 10/25 C* FZA 14 x 60 M 10/50 C FZA 18 x 80 M 12/25 C* FZA 18 x 80 M 12/55 C FZA 22 x 100 M 16/60 C FZA 22 x 125 M 16/60 C FZA 12 x 50 M 8 D/10 C FZA 12 x 60 M 8 D/10 C FZA 12 x 80 M 8 D/30 C FZA 14 x 80 M 10 D/20 C FZA 18 x 100 M 12 D/20 C FZA 18 x 130 M 12 D/50 C 96214 96361 96215 96228 96227 96362 96216 96358 96315 96359 96364 96360 96319 96353 96354 96355 96356 96357 10 10 12 14 12 12 14 14 18 18 22 22 12 12 12 14 18 18 40 40 40 40 50 50 60 60 80 80 100 125 40 50 50 60 80 80 10 35 15 25 15 50 25 50 25 55 60 60 10 10 30 20 20 50 M 6 M 6 M 8 M 10 M 8 M 8 M 10 M 10 M 12 M 12 M 16 M 16 M 8 M 8 M 8 M 10 M 12 M 12 10 10 13 17 13 13 17 17 19 19 24 24 13 13 13 17 19 19 25 25 25 25 20 20 10 10 10 10 10 6 25 25 25 10 10 10 * For the correct resins FIS HB 345 S and FIS HB 150 C. No.4529 Available with glass capsule RM or injection resin FIS V.see page 13 Stainless steel 1.4529 See page 25. anchorage depth mm l Fixing length mm da Max. anchorage depth mm Max. per pack Type Art. both with ETA Type Art. fixing thickness mm M SW Width across nut Qty. Tools Type Art. drillhole depth mm Min. delivery times and other dimensions available on request.4529 do ho Drillhole depth mm Type Art. drillhole depth for through fixing mm hv Min.4529 approval . see page 2. Drill mm hef Effect. Resin anchor threaded rod RG M C Material 1. delivery times and other dimensions available on request. max. Hammerset anchor FZEA C Type Art.4529) Technical data Highbond anchor FHB-A C Material 1.HIGH PERFORMANCE STEEL ANCHORS Anchors made of highly corrosion-resistant steel Technical data Zykon anchor FZA C Highly corrosion-resistant stainless steel (material: 1. Stainless steel 1. Drill mm Thread FNA 6 x 30/5 C* FNA 6 x 30/30 C* 77807 77808 6 6 6 50 75 50 30 30 30 45 71 52 5 30 5 – – M6 – – 10 100 50 100 FNA 6 x 30 M 6/5 C* 77809 * Approval pending Material 1. Qty. fischer Anchor bolt FAZ Information on this product range and sizes was not available at time of printing. Prices. Drill mm Anchorage depth mm Internal thread Screw-in depth mm min. anchorage depth mm Max. No. For further details please contact fischer customer services 01491 827900 53 . per. delivery times and other dimensions available on request. Drill mm Min. delivery times and other dimensions available on request. No. fixing thickness mm Thread Width across nut Qty. No. No. Prices. per pack RG M 8 x 110 C* RG M 10 x 130 C* RG M 12 x 160 C* RG M 16 x 190 C* 96316 96217 96218 96219 10 12 14 18 80 90 110 125 80 90 110 125 13 20 25 35 50270 50271 50272 50273 13 17 19 24 10 10 10 10 * Article available from stock. HIGH PERFORMANCE STEEL ANCHORS For your notes 54 .