Fire Alarm Cables

March 19, 2018 | Author: Traves Taylor | Category: Cable, Wire, Insulator (Electricity), Electrical Conductor, Building Engineering


Comments



Description

Fire Alarm CablesLife. Safety. Fire alarm systems serve as life lines to safe and secure buildings. As one of the original manufacturers of fire alarm cable, West Penn Wire knows proper cable selection is critical to effective system performance. With over 100 variations of cable constructions, environmental ratings, colors, and striping options, we have the right fire alarm cable. Match the right cable to system demand and ensure a safe building. B C C B A A A C B A B FEATURES • Solid Conductor Constructions • Stranded Conductor Constructions • Power Limited Data Grade Designs • Available in Multiple Jacket Colors • Avialable with Strips • Circuit Integrity Designs • Local Law 5 (NYC) Designs • Indoor/Outdoor Design in Aquaseal Sectionpgs. 43-44 NEW: NYC- Local Law 5 Cables Stranded Conductor Cables MINI INDEX A B C Power-Limited Cables FPLR/ Unshielded ………………………………………… 48 FPLR/ Shielded …………………………………………… 49 FPLR and FPLP- Low Cap/ Unshielded & Shielded……… 50 FPL/ One and Two Conductor…………………………… 51 FPLP/ Unshielded ……………………………………… 52 FPLP/ Shielded ………………………………………… 53 Local Law 5 LL5 Unshielded ……………………………… 54 Local Law 5 LL5 Shielded ……………………………… 55 FPLR and FPLP Stranded Conductors…………………… 57-58 Non Power-Limited Cables NPLF/ Unshielded ………………………………………… 56 NPLF/ Shielded …………………………………………… 56 Circuit Integrity Circuit Integrity in Conduit (CIC)/ Shielded……………… 59 Circuit Integrity in Conduit (CIC)/ Unshielded…………… 60 Circuit Integrity (CI)/ Shielded…………………………… 61 Circuit Integrity (CI)/ Unshielded………………………… 62 WEST PENN WIRE CABLE WITH CONFIDENCE 47 800-245-4964 • www.westpenn-wpw.com BL. WH.Green Tracer Color Code.017 PVC .017 PVC .008 PVC .Tracer GN.017 PVC . YE 18 AWG Solid 6. YE RD.008 PVC .168 FPL R 32 pf/ft* 16 AWG Solid 4.012 None PVC .017 . O.Shielding Jacket Type & D.146 FPL R 29 pf/ft* RD.008 PVC . YE RD.198 FPL R 32 pf/ft* 14 AWG Solid 2. BL. WH.D.1 Ω/Mft None . of Cond. YE Red RD.017 PVC .170 FPL R 29 pf/ft* 1 Pair 4 1 Pair 16 AWG Solid 4.On a Red Jacket only 980T-GN T.westpenn-wpw. Nom.246 FPL R 35 pf/ft* Red 1 Pair 12 AWG Solid 1.008 PVC . WH. Capacitance Jacket Color 800-245-4964 • www. Type & Thick.5 Ω/Mft None .R ness Thickness Inches Inches Standard spool size 1000ft.5 Ω/Mft PVC .See page 49 48 CABLE WITH CONFIDENCE WEST PENN WIRE .210 FPL R 35 pf/ft* 4 14 AWG Solid 2. Inches NEC Type Nom.244 FPL R 45 pf/ft* Red Special Notes: • Selected Plenum Versions see pages 52 • Selected Indoor/Outdoor Aquaseal Water Resistant® Versions see Aquaseal Section pg.017 PVC . No.43 • Select Items are Packaged in our Advantage Box • Orange rip cord under jacket Tracer Marks: Available upon Request: Minimum Quantities may apply Example:.012 PVC .6 Ω/Mft None .com 980 982 990 992 994 700 998 1 Pair 4 18 AWG Solid 6.1 Ω/Mft None . BL. BL.Fire Alarm Cables Fire Alarm Cables Power-Limited Multiple Conductor/ Unshielded Description: • ASTM bare copper • PVC insulation • Twisted pair or cabled construction • Overall PVC jacket Applications: Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Rating: • NEC Type FPLR • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: UL1666 Catalog No.8 Ω/Mft None . Conductor Insulation Type & Nom.017 PVC .6 Ω/Mft None . WH.C.012 PVC . Red.017 .012 PVC .6 Ω/Mft .017 PVC . BL.150 FPL R 73 pf/ft* 133 pf/ft** 73 pf/ft* 133 pf/ft** 82 pf/ft* 148 pf/ft** 82 pf/ft* 148 pf/ft** 84 pf/ft* 151 pf/ft** 96 pf/ft* 173 pf/ft** RD. YE Red 16 AWG Solid 4. Brown.5 Ω/Mft PVC .White. Foil 100% Al. WH.008 PVC .5 Ω/Mft . Foil 100% Al. All Cables JACKET: RD-Red.215 FPL R Red 12 AWG Solid 1.8 Ω/Mft .017 PVC . 975 977 991 993 995 999 1 Pair 4 18 AWG Solid 6.180 FPL R 1 Pair 4 16 AWG Solid 4. Foil 100% Al.200 FPL R 1 Pair 1 Pair 14 AWG Solid 2.008 PVC . Catalog No. Foil 100% Al. Foil 100% Al. • Orange rip cord under jacket • STRANDED VERSIONS SEE PAGE 58.017 PVC . WH. WH. BL-Blue.R ness Coverage Thickness Inches Inches .248 FPL R Red * Capacitance between conductors.Tracer GN. Capacitance Jacket Color Standard spool size 1000ft.westpenn-wpw. No.D. 3. Type & Thick&% Jacket Type & D. O. of Cond.1 Ω/Mft .012` Al.Green Tracer WEST PENN WIRE CABLE WITH CONFIDENCE 49 800-245-4964 • www.44 • Select Items are Packaged in our Advantage Box. Foil 100% PVC . BL.Black.172 FPL R RD.On a Red Jacket only 975T-GN T.010 PVC . 2.com Conductor Insulation Shielding Type & Nom.1 Ω/Mft . 4.Fire Alarm Cables Fire Alarm Cables Power-Limited Multiple Conductor/ Shielded Applications: Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Description: • ASTM bare copper • PVC insulation • Twisted pair or cabled construction • Overall shield 100% coverage of aluminum polyester foil binders as required with 24 AWG TC drain wire • Overall PVC jacket Rating: • NEC Type FPLR • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: UL1666 Nom.017 PVC . Inches NEC Type Nom.C.017 PVC . YE-Yellow Tracer Marks: Available upon Request: Minimum Quantities may apply Example:. YE Red 18 AWG Solid 6. Blue Special Notes: • Selected Plenum Versions see pages 53 • Selected Indoor/Outdoor Aquaseal Water Resistant® Versions see Aquaseal Section pg.008 PVC . ** Capacitance between one conductor and the other connected to the shield Color Code 1. 2. Inches NEC Type Nom. 3. No.westpenn-wpw.6 Ω/Mft Polyolefin .D.Fire Alarm Cables Power-Limited / Addressable Systems/ Description: • ASTM bare copper • Polyolefin insulation • Short overall twist lengths • Unshielded construction • Overall PVC jacket Unshielded Data Cable Applications: Indoor data cable for: • Data Circuits • Addressable Systems • Initiating Circuits • Notification Circuits Standard spool size 1000ft.Black.D.226 FPL R Red . Brown. Inches NEC Type Nom.030 . of Cond. Foil 100% PVC .030 PVC .Shielding Jacket Type & Thickness D. Blue * Capacitance between conductors. Foil 100% Al.R ness Inches Inches 800-245-4964 • www. Catalog No. Conductor Insulation Type & Nom.5 Ω/Mft 16 AWG Polyolefin Solid .015 4. Nom. Power-Limited / Shielded Addressable Systems/ Data Cable Description: • ASTM bare copper • Polyolefin insulation • Short overall twist length • Overall shield 100% coverage of aluminum polyester foil with 24 AWG TC drain wire • Overall PVC jacket Standard spool size 1000ft. Capacitance Jacket Color D975 D991 D995 1 Pair 1 Pair 1 Pair 18 AWG Solid 6. Type & Thick& D.030 PVC .015 6. Capacitance Jacket Color Rating: • NEC Type FPLR • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: UL1666 Catalog No.015 Polyolefin .262 FPL R Red Color Code 1.1 Ω/Mft 14 AWG Solid 2. Type & Thick.com D980 D990 1 Pair 1 Pair 18 AWG Polyolefin Solid . O. of Cond.223 FPL R 18 pf/ft* Red * Capacitance between conductors.C.015 Polyolefin .5 Ω/Mft 16 AWG Solid 4.R ness % Coverage Thickness Inches Inches Nom. Foil 100% Al.030 PVC .182 FPL R 16 pf/ft* Red None . O.C. Conductor Insulation Shielding Jacket Type & Type & Nom.210 FPL R 25 pf/ft* 45 pf/ft** 30 pf/ft* 54 pf/ft** 30 pf/ft* 54 pf/ft** Red .020 Al. No. Red. ** Capacitance between one conductor and the other connected to the shield All Cables JACKET: Red Special Notes: • Selected Plenum Versions see pages 53 • Orange rip cord under jacket 50 CABLE WITH CONFIDENCE WEST PENN WIRE . 4.030 .1 Ω/Mft None PVC . 204 FPL -- Red 2 16 AWG Solid 4. Inches NEC Type Nom. Type & ThickD.032 PVC .C.250 FPL -- Red Colors Jacket Colors Red NOTE: Additional Colored Jackets are available upon request. Conductor Insulation Type & Nom.PERFECTSTRIPE® Applications: Indoor for: • Power-Limited Protective Circuits Rating: • NEC Type FPL • (UL) Listed • Flame Rating: UL1685 Parallel Construction. Minimum quantity orders may apply.225 FPL -- Red 2 14 AWG Solid 2. No.Fire Alarm Cables Fire Alarm Cables Description: Power-Limited One & Two Conductor/ • ASTM bare copper • PVC insulation Parallel • Two conductor parallel features.032 PVC . of Cond. Capacitance Jacket Color 970 971 972 2 6.104x. O.5 Ω/Mft PVC .115x.com 18 AWG Solid .D.R ness Inches Shielding Jacket Type & Thickness Inches Nom. • Items are Packaged in our Advantage Box WEST PENN WIRE CABLE WITH CONFIDENCE 51 800-245-4964 • www.westpenn-wpw.6 Ω/Mft None -- .Two Conductor Catalog No.032 None --- .1 Ω/Mft None .128x. 144 FPL P 29 pf/ft* Red 4 1 Pair 18 AWG Solid 6.plenums and other spaces used for environmental air: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Rating: • NEC Type FPLP • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: NFPA-262 Smoke & Flame Test Catalog No. O. OR. 2.8 Ω/Mft .Green Tracer Color Code 1.166 FPL P 29 pf/ft* Red RD.5 Ω/Mft . Tracer Marks: Available upon Request: Minimum Quantities may apply Example:.010 None .015 .191 FPL P 32 pf/ft* Red 1 Pair 4 14 AWG Solid 2.008 None . 4.westpenn-wpw.6 Ω/Mft .008 None .164 FPL P 32 pf/ft* 4 16 AWG Solid 4.R ness Thickness Inches Inches Standard spool size 1000ft.015 .236 FPL P 35 pf/ft* Red 1 Pair 12 AWG Solid 1. Conductor Insulation Type & Nom. Capacitance Jacket Color 800-245-4964 • www. BL.C. YE 14 AWG Solid 2. WH-White.Red. YE. BL-Blue.On a Red Jacket only 60980BT-GN T.Black.015 . Nom. 3.Fire Alarm Cables Fire Alarm Cables Power-Limited/ Unshielded Plenecon II ® Extra Flexible Description: • ASTM bare copper • Polymer alloy insulation • Twisted pair or cabled construction • Flexible plenum jacket Applications: Indoor within ducts.Tracer GN.1 Ω/Mft . BL.D.1 Ω/Mft .010 None . OR-Orange. Special Notes: • Plenum Installation precautions see Technical Reference Section pg. Brown. Red. Type & Thick.Shielding Jacket Type & D.6 Ω/Mft . YE 16 AWG Solid 4.198 FPL P 35 pf/ft* RD.196 • Select Items are Packaged in our Advantage Box • STRANDED VERSIONS SEE PAGE 58.015 . WH.015 .5 Ω/Mft .010 None .239 FPL P 45 pf/ft* Red * Capacitance between conductors.Yellow 52 CABLE WITH CONFIDENCE WEST PENN WIRE .015 . Inches NEC Type Nom.008 None .com 60980B 60982B 60991B 60164B 60993B 60700B 60995B 1 Pair 18 AWG Solid 6.015 . of Cond. No. Blue All Cables JACKET: Red RD.008 None . 5 Ω/Mft . No. 60975B 60977B 60990B 603164B 60992B 60994B 1 Pair 4 18 AWG Solid 6.012 Al.008 Al.C. Foil 100% Al. Foil 100% Al.188 FPL P Red ^ . 3. Foil 100% Al.D.015 . 2.010 . Foil 100% .202 FPL P Red 12 AWG Solid 1.Data grade versions for addressable systems contain Low Loss Insulation and Overall Flexible Plenum Jacket.6 Ω/Mft .Tracer GN.015 .1 Ω/Mft .5 Ω/Mft .1 Ω/Mft .170 FPL P Red 1 Pair 16 AWG Solid 4.015 . * Capacitance between conductors.008 .Black.195 FPL P Red 14 AWG Solid 2.com Conductor Insulation Shielding Type & Nom. Red.On a Red Jacket only 60980BT-GN T. Blue Special Notes: • Plenum Installation precautions see Technical Reference Section pg.westpenn-wpw.196 Tracer Marks: Available upon Request: Minimum Quantities may apply Example:. of Cond.1 Ω/Mft . O.148 FPL P 54 pf/ft* 97 pf/ft** 54 pf/ft* 97 pf/ft** 61 pf/ft* 110 pf/ft** 61 pf/ft* 110 pf/ft** 84 pf/ft* 151 pf/ft** 96 pf/ft* 173 pf/ft** Red 18 AWG Solid 6. Foil 100% Al. Catalog No.015 .015 . Foil 100% Al.015 .008 . Brown.Green Tracer All Cables JACKET: Red WEST PENN WIRE CABLE WITH CONFIDENCE 53 800-245-4964 • www. Inches NEC Type Nom.015 .168 FPL P Red 4 1 Pair 1 Pair 16 AWG Solid 4.165 FPL P 25 pf/ft* 45 pf/ft** 30 pf/ft* 54 pf/ft** Red 16 AWG Solid 4.010 . Capacitance Jacket Color Standard spool size 1000ft.5 Ω/Mft . 4.Fire Alarm Cables Fire Alarm Cables Power-Limited / Shielded Plenecon II ® Extra Flexible Applications: Indoor within ducts.243 FPL P Red DATA GRADE PLENUM D60975 ^ D60990 ^ 1 Pair 1 Pair 18 AWG Solid 6.012 . Foil 100% . Type & Thick& Jacket Type & D. ** Capacitance between one conductor and the other connected to the shield Color Code 1.plenums and other spaces used for environmental air: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Description: • ASTM bare copper • Polymer Alloy insulation • Twisted pair or cabled construction • Overall shield 100% coverage of aluminum polyester foil with 24 AWG TC drain wire • Flexible plenum jacket Rating: • NEC Type FPLP • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: NFPA-262 Smoke & Flame Test Nom. Foil 100% Al.R ness % Coverage Thickness Inches Inches .015 .8 Ω/Mft .008 . 016 None .026 .026 .Black.8 Ω/Mft .R ness Thickness Inches Inches Nom.016 None . Applications: Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Rating: Power Limited Fire Alarm Cable also classified for use as Fire Alarm Cable in New York City. Red All Cables JACKET: Red 54 CABLE WITH CONFIDENCE WEST PENN WIRE . of Cond.5 Ω/Mft .5 Ω/Mft .026 .190 FPL P 29 pf/ft* Red 4 1 Pair 18 AWG Solid 6.026 .016 None . • NEC Type FPLP • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: NFPA-262 Smoke & Flame Test Catalog No.026 .016 None . Conductor Insulation Type & Nom.Shielding Jacket Type & D.C.252 FPL P 35 pf/ft* Red 1 Pair 12 AWG Solid 1. Inches NEC Type Standard spool size 1000ft.1 Ω/Mft .175 FPL P 29 pf/ft* Red 16 AWG Solid 4.6 Ω/Mft . Capacitance Jacket Color 800-245-4964 • www.1 Ω/Mft .Fire Alarm Cables Fire Alarm Cables Local Law 5 (LL5) Power-Limited/ Unshielded Description: • ASTM bare copper • Fluropolymer • Twisted pair or cabled construction • Unshielded • Fluoropolymer jacket. O.026 .016 None .225 FPL P 45 pf/ft* Red Special Notes: • Orange rip cord under jacket • Plenum Installation precautions see Technical Reference Section pg.westpenn-wpw.016 None .D.com LL5182 LL5184 LL5162 LL5164 LL5142 LL5144 LL5122 1 Pair 18 AWG Solid 6.191 FPL P 35 pf/ft* Red 14 AWG Solid 2. No.196 Color Code 1.150 Deg. 2.026 . Type & Thick. Nom.6 Ω/Mft .016 None .161 FPL P 32 pf/ft* Red 4 16 AWG Solid 4.220 FPL P 32 pf/ft* Red 1 Pair 4 14 AWG Solid 2. Fire Alarm Cables Fire Alarm Cables Local Law 5 (LL5) Power Limited/ Shielded Applications: Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Description: • ASTM bare copper • Fluoropolymer • Twisted pair or cabled construction • Overall shield 100% coverage of aluminum polyester foil with TC drain wire • Fluropolymer jacket Rating: Power Limited Fire Alarm Cable also classified for use as Fire Alarm Cable in New York City. Capacitance Jacket Color Standard spool size 1000ft.8 Ω/Mft . • NEC Type FPLP • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: NFPA-262 Smoke & Flame Test Nom. ** Capacitance between one conductor and the other connected to the shield Color Code 1.1 Ω/Mft .194 FPL P 54 pf/ft* 97 pf/ft** 54 pf/ft* 97 pf/ft** 61 pf/ft* 110 pf/ft** 61 pf/ft* 110 pf/ft** 84 pf/ft* 151 pf/ft** 96 pf/ft* 173 pf/ft** Red 18 AWG Solid 6. Foil 100% Al.016 . Foil 100% Al. NEC Type Nom. Blue All Cables Special Notes: • Orange rip cord under jacket • Plenum Installation precautions see Technical Reference Section pg.016 .026 .196 JACKET: Red WEST PENN WIRE CABLE WITH CONFIDENCE 55 800-245-4964 • www.com .026 . Catalog No. Foil 100% Al. 4.Black.026 .267 FPL P Red LL5142SH 14 AWG Solid 2. of Cond. Type & Thick& Jacket Type & D.026 .016 Al. O.5 Ω/Mft .016 .215 FPL P Red LL5164SH 4 1 Pair 1 Pair 16 AWG Solid 4.D. Red.westpenn-wpw.R ness % Coverage Thickness Inches LL5182SH LL5184SH 1 Pair 4 18 AWG Solid 6.C.026 .026 .1 Ω/Mft .243 FPL P Red LL5162SH 1 Pair 16 AWG Solid 4.5 Ω/Mft .016 .016 .242 FPL P Red LL5122SH 12 AWG Solid 1. No.275 FPL P Red * Capacitance between conductors. Foil 100% Al. Foil 100% . Conductor Insulation Shielding Type & Nom. Brown. 2.6 Ω/Mft . Foil 100% Al. 3. Fire Alarm Cables Fire Alarm Cables Nonpower-Limited/ Unshielded Applications: Description: • ASTM bare copper • PVC insulation with Nylon • Overall PVC jacket Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Rating: • NEC Type NPLF • (UL) Listed • Meets 150V requirements as specified in the NEC • Flame Rating: UL1685 Standard spool size 1000ft. Inches NEC Type Standard spool size 1000ft. Type & Thick.005 None PVC .037 .016 Nylon .016 Nylon . Capacitance Jacket Color 1975 1 Pair 18 AWG Solid 6.6 Ω/Mft None PVC .037 . ** Capacitance between one conductor and the other connected to the shield Color Code 1.005 PVC . Foil 100% PVC .com Catalog No.016 Nylon . Foil 100% PVC . Inches NEC Type Nom.1 Ω/Mft PVC . O.016 Nylon . of Cond.037 .5 Ω/Mft 1991 1 Pair 16 AWG Solid 4.005 PVC .252 NPLF -- Red 1994 1 Pair 14 AWG Solid 2. No. 2. No. Capacitance Jacket Color 800-245-4964 • www.C. O.R ness % Coverage Inches Inches Nom. Foil 100% PVC . Nom.Black. of Cond.6 Ω/Mft PVC . Red All Cables JACKET: Red 56 CABLE WITH CONFIDENCE WEST PENN WIRE . Type & Thick& & Thickness D.westpenn-wpw.R ness Thickness Inches Inches 1990 1 Pair 16 AWG Solid 4.278 NPLF -- Red Rating: • NEC Type NPLF • (UL) Listed • Flame Rating: UL1685 Catalog No.264 NPLF 57 pf/ft* 103 pf/ft** Red Al. Nom. Conductor Insulation Type & Nom.005 PVC .D. Conductor Insulation Shielding Jacket Type Type & Nom.037 .284 NPLF 64 pf/ft* 115 pf/ft** Red Special Notes: • Orange rip cord under jacket * Capacitance between conductors.Shielding Jacket Type & D.016 Nylon .037 .D.C.005 Al.1 Ω/Mft 1995 1 Pair 14 AWG Solid 2.244 NPLF 52 pf/ft* 94 pf/ft** Red Al. 1.com Nom.Shielding Jacket Type & D. Inches NEC Type Nom.westpenn-wpw. Type & Thick.Fire Alarm Cables Stranded Conductor Fire Alarm Cables Power-Limited Multiple Conductor/ Unshielded Description: • ASTM Stranded bare copper • PVC insulation • Twisted pair or cabled construction • Overall PVC jacket Applications: Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Rating: • NEC Type FPLR • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: UL1666 Catalog No.R ness Thickness Inches Inches 60991BS 60993BS 60995BS 1 Pair 1 Pair 1 Pair 16 AWG Stranded 4.D.164 FPL P 32 pf/ft* Red 14 AWG Standed 2.C.239 FPL P 45 pf/ft* Red WEST PENN WIRE CABLE WITH CONFIDENCE 57 800-245-4964 • www.1 Ω/Mft PVC .224 FPL R 35 pf/ft* Red 12 AWG Strd. O.D. 4.008 None .8 Ω/Mft .6 Ω/Mft . Type & Thick. No.015 . 2.Shielding Jacket Type & D.C.198 FPL P 35 pf/ft* Red 12 AWG Stranded 1.009 PVC . of Cond. O. Inches NEC Type Nom.010 None PVC . of Cond. 990S 994S 998S 1 Pair 1 Pair 1 Pair 16 AWG Strd.1 Ω/Mft . Capacitance Jacket Color .010 None .017 PVC .017 PVC .8 Ω/Mft None .R ness Thickness Inches Inches Standard spool size 1000ft.6 Ω/Mft None .015 . Capacitance Jacket Color Rating: • NEC Type FPLP • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: NFPA-262 Smoke & Flame Test Catalog No. Nom. No.182 FPL R 32 pf/ft* Red 14 AWG Strd.010 None . Conductor Insulation Type & Nom.015 .017 . Conductor Insulation Type & Nom.010 PVC .260 FPL R 45 pf/ft* Red Stranded Conductor Fire Alarm Cables Plenum Power-Limited/ Unshielded Standed Conductors Extra Flexible Description: • ASTM Stranded bare copper • Polymer alloy insulation • Twisted pair or cabled construction • Flexible plenum jacket Applications: Plenum Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Standard spool size 1000ft. Shielding Jacket Type & Thickness D.264 FPL R Red Stranded Conductor Fire Alarm Cables Plenum Power-Limited/ Shielded Standed Conductors Extra Flexible Description: • ASTM Stranded bare copper • Polymer Alloy insulation • Twisted pair • Overall shield 100% coverage of aluminum polyester foil with 24 AWG TC drain wire • Flexible plenum jacket Applications: Plenum Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Rating: • NEC Type FPLP • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: NFPA-262 Smoke & Flame Test Catalog No.017 PVC .R ness Thickness Inches Inches 995S 999S 1 Pair 1 Pair 14 AWG Stranded 2.Fire Alarm Cables Stranded Conductor Fire Alarm Cables Power-Limited Multiple Conductor/ Shielded Description: • ASTM Stranded bare copper • Polymer Alloy insulation • Twisted pair • Overall shield 100% coverage of aluminum polyester foil with 24 AWG TC drain wire • Flexible plenum jacket Applications: Indoor for: • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Rating: • NEC Type FPLR • (UL) Listed • Meets 300V requirements as specified in the NEC • Flame Rating: UL1666 Standard spool size 1000ft.R ness Inches Inches Standard spool size 1000ft.C. O.D.174 FPL P 61 pf/ft* 110 pf/ft** 84 pf/ft* 151 pf/ft** 96 pf/ft* 173 pf/ft** Red 14 AWG Stranded 2. Capacitance Jacket Color 800-245-4964 • www. Foil 100% Al. Foil 100% Al.012 PVC .6 Ω/Mft PVC .015 .D. Conductor Insulation Type & Nom.010 . Type & Thick.010 . Nom.com Catalog No. O.westpenn-wpw. Conductor Insulation Type & Nom.232 FPL R 84 pf/ft* 151 pf/ft** 96 pf/ft* 173 pf/ft** Red 12 AWG Stranded 1.8 Ω/Mft . No.015 .015 . Foil 100% PVC .8 Ω/Mft .017 .Shielding Jacket Type & D. Capacitance Jacket Color 60990BS 60992BS 60994BS 1 Pair 1 Pair 1 Pair 16 AWG Stranded 4. of Cond. of Cond. Inches NEC Type Nom.008 Al.012` Al. Inches NEC Type Nom. Type & Thick. Foil 100% .C.210 FPL P Red 12 AWG Stranded 1. Nom. No.249 FPL P Red 58 CABLE WITH CONFIDENCE WEST PENN WIRE .1 Ω/Mft .6 Ω/Mft . Foil 100% Al. 056 FRPE . Type & Thick& Jacket Type & D.5 Ω/Mft .36 FPL R 20pf/ft* Red 4 16 AWG Solid 4.2 Hour Flame Test ( in conduit only) Nom. Conductor Insulation Shielding Type & Nom. Color Code All Cables Black.035 CSR .R ness % Coverage Thickness Inches Inches 5200FZ 5220FZ 5222FZ 5100FZ 5120FZ 5000FZ 2 16 AWG 7x24 4.056 . of Cond. Foil 100% FRPE .Ceramifiable Silicon Rubber • FRPE. Non-Halogen Jacket Rating: • NEC Type FPLR • (UL) Listed • Meets 300V requirements as specified in the NEC .41 26pf/ft* Red 2 14 AWG Solid 2.035 CSR .D. Red. CIC cables can not be deployed outside the conduit and mantain a CI rating.C. No.4 or more are Black and numbered Special Notes: • CSR. Foil 100% Al.5 Ω/Mft . O.6 Ω/Mft . Foil 100% Al.056 FRPE .035 CSR .37 FPL R 22pf/ft* Red 2 16 AWG Solid 4.0 Ω/Mft CSR .Fire Alarm Cables Circuit Integrity in Conduit/ (CIC) . Capacitance Jacket Color Catalog No. Foil 100% Al.056 FRPE .com Standard spool size 1000ft.035 CSR .Flame Retardant Polyethylene • CIC Cables have been tested to pass the 2 hour UL2196 Flame test in conduit. UL2196 .38 FPL R 23pf/ft* Red 2 12 AWG 7x20 1. .0 Ω/Mft .0 Ω/Mft .105°C • Flame Rating: UL1666. Foil 100% Al.44 FPL R 27pf/ft* Red * Capacitance between conductors. Foil 100% Al.westpenn-wpw.41 FPL R FPL R 16pf/ft* Red 2 14 AWG 7x22 2. JACKET: Red WEST PENN WIRE CABLE WITH CONFIDENCE 59 800-245-4964 • www. Inches NEC Type Nom.056 FRPE .035 CSR .056 FRPE .035 Al.Riser Rated Applications: Indoor for: • Circuit Integrity • Fire Alarm Circuit Integrity • Survivability Shielded Description: • ASTM bare copper • Ceramifiable Silicon Rubber (CSR) Insulation • Twisted pair or cabled construction • Overall shield 100% coverage of aluminum polyester foil with TC drain wire • Overall FRPE Low-Smoke. UL2196 . Red All Cables JACKET: Red CABLE WITH CONFIDENCE WEST PENN WIRE .(CIC) Description: • ASTM bare copper • Ceramifiable Silicon Rubber (CSR) Insulation • Twisted pair or cabled construction • Overall FRPE Low-Smoke. No.38 FPL R 17pf/ft* Red * Capacitance between conductors.056 FRPE .105°C • Flame Rating: UL 1666.035 CSR . Conductor Insulation Type & Nom.056 FRPE .westpenn-wpw.0 Ω/Mft None .D.35 FPL R 15pf/ft* Red 2 14 AWG 7x22 2. Capacitance Jacket Color 800-245-4964 • www. Type & Thick. of Cond. CIC cables can not be deployed outside the conduit and maintain a CI rating. Non-Halogen Jacket Applications: Indoor for: • Circuit Integrity • Fire Alarm Circuit Integrity • Survivability Rating: • NEC Type FPLR • (UL) Listed • Meets 300V requirements as specified in the NEC .37 FPL R 16pf/ft* Red 2 16 AWG Solid 4.035 CSR . Color Code Black.Shielding Jacket Type & D. Inches Standard spool size 1000ft. Special Notes: • CSR.40 FPL R 18pf/ft* Red 2 14 AWG Solid 2.Ceramifiable Silicon Rubber • FRPE.Flame Retardant Polyethylene • CIC Cables have been tested to pass the 2 hour UL2196 Flame test in conduit.035 None FRPE .056 .com 60 5200UZ 5220UZ 5100UZ 5120UZ 2 16 AWG 7x24 4.035 CSR .056 FRPE .C.5 Ω/Mft None . O.Two Hour Flame Test ( in conduit only) Catalog No.0 Ω/Mft CSR .Fire Alarm Cables Circuit Integrity in Conduit/ Unshielded Riser Rated .R ness Thickness Inches Inches Nom.5 Ω/Mft None . NEC Type Nom. Riser Rated Applications: Indoor for: • Circuit Integrity • Fire Alarm Circuit Integrity • Survivability Description: • ASTM bare copper • Ceramifiable Silicon Rubber (CSR) Insulation • Twisted pair or cabled construction • Overall shield 100% coverage of aluminum polyester foil with TC drain wire • Overall FRPE Low-Smoke. 60 * Capacitance between conductors.045 . Foil 100% Al.38 FPL R -CI 33pf/ft* Red 2 12 AWG Solid 1. No.034 CSR .045 FRPE . Foil 100% Al.5 Ω/Mft .034 CSR .9 Ω/Mft CSR .Fire Alarm Cables Circuit Integrity/ Shielded (CI) .045 FRPE . Foil 100% Al.41 FPL R -CI 33pf/ft* Red 2 14 AWG 7x22 2. WEST PENN WIRE CABLE WITH CONFIDENCE 61 800-245-4964 • www.034 CSR .32 FPL R -CI 27pf/ft* Red 4 18 AWG 7x26 5.36 FPL R -CI 27pf/ft* Red 2 18 AWG 7x26 5. Foil 100% Al.0 Ω/Mft . Foil 100% FRPE . Foil 100% Al.36 FPL R -CI 33pf/ft* Red 4 14 AWG Solid 2.045 FRPE .034 CSR .D. Foil 100% Al. O.46 FPL R -CI 37pf/ft* Red Notes: Color Code Pg.33 FPL R -CI 31pf/ft* Red 4 16 AWG Solid 4.37 FPL R -CI 27pf/ft* Red 2 16 AWG Solid 4.35 FPL R -CI 31pf/ft* Red 2 14 AWG Solid 2.com Conductor Insulation Shielding Type & Nom.0 Ω/Mft .045 FRPE .9 Ω/Mft .045 FRPE .38 FPL R -CI 31pf/ft* Red 2 16 AWG 7x24 4.6 Ω/Mft .39 FPL R -CI 37pf/ft* Red 4 12 AWG Solid 1.9 Ω/Mft .31 FPL R -CI 27pf/ft* Red 4 18 AWG Solid 5.westpenn-wpw.R ness % Coverag Thickness Inches Inches .034 CSR . Type & Thick& Jacket Type & D. 5320FM 5322FM 5300FM 5302FM 5220FM 5222FM 5200FM 5120FM 5122FM 5100FM 5020FM 5022FM 2 18 AWG Solid 5. of Cond.9 Ω/Mft .5 Ω/Mft .5 Ω/Mft .045 FRPE . Foil 100% Al.6 Ω/Mft .045 FRPE . Foil 100% Al. Inches NEC Type Nom.034 CSR .034 Al.034 CSR . Foil 100% Al. Foil 100% Al.105°C • Flame Rating: UL1666.034 CSR .045 FRPE .034 CSR .0 Ω/Mft . Non Halogen Jacket Rating: • NEC Type FPLR-CI • (UL) Listed • Meets 300V requirements as specified in the NEC .034 CSR .034 CSR . Capacitance Jacket Color Standard spool size 1000ft. UL2196 .045 FRPE .2 Hour Flame Test Nom.C.045 FRPE . Catalog No. Foil 100% Al.045 FRPE . Non-Halogen Jacket Rating: • NEC Type FPLR-CI • (UL) Listed • Meets 300V requirements as specified in the NEC .westpenn-wpw.045 FRPE . UL2196.5 Ω/Mft None . CI rated cables can not be deployed in conduit and maintain a CI rating.9 Ω/Mft None .034 CSR .034 None FRPE .045 FRPE .045 FRPE .034 CSR . NEC Type Nom.R ness Thickness Inches Inches Nom.38 FPL R -CI 19pf/ft* Red 2 14 AWG Solid 2. Capacitance Jacket Color 800-245-4964 • www. Special Notes: • CSR.Fire Alarm Cables Circuit Integrity / Unshielded Riser Rated . Inches Standard spool size 1000ft.045 FRPE . O. of Cond. Type & Thick.0 Ω/Mft None .45 FPL R -CI 23pf/ft* Red * Capacitance between conductors. Red. No.41 FPL R -CI 21pf/ft* Red 2 12 AWG Solid 1.034 CSR . Color Code All Cables Black.045 .5 Ω/Mft None .com 5320UM 5322UM 5220UM 5222UM 5120UM 5122UM 5020UM 5022UM 2 18 AWG Solid 5.36 FPL R -CI 21pf/ft* Red 4 14 AWG Solid 2.C. Conductor Insulation Type & Nom.31 FPL R -CI 17pf/ft* Red 4 18 AWG Solid 5.39 FPL R -CI 23pf/ft* Red 4 12 AWG Solid 1.Ceramifiable Silicon Rubber • FRPE.9 Ω/Mft CSR .4 or more are Black and numbered JACKET: Red 62 CABLE WITH CONFIDENCE WEST PENN WIRE .034 CSR .6 Ω/Mft None .045 FRPE .045 FRPE .35 FPL R -CI 17pf/ft* Red 2 16 AWG Solid 4.D.045 FRPE .(CI) Applications: Indoor for: • Circuit Integrity • Fire Alarm Circuit Integrity • Survivability Description: • ASTM bare copper • Ceramifiable Silicon Rubber (CSR) Insulation • Twisted pair or cabled construction • Overall FRPE Low-Smoke.33 FPL R -CI 19pf/ft* Red 4 16 AWG Solid 4.6 Ω/Mft None .Two Hour Flame Test Catalog No.034 CSR .105°C • Flame Rating: UL 1666.Shielding Jacket Type & D.034 CSR .034 CSR .0 Ω/Mft None .Flame Retardant Polyethylene • CI Cables have been tested to pass the 2 hour UL2196 Flame test not in conduit.
Copyright © 2024 DOKUMEN.SITE Inc.