Catalogue10 11 www.hagerbr.com.au Catalogue 10 11 Disclaimer Whilst Hager B&R has made every effort to ensure that all information contained herein is correct at the time of printing, we reserve the right, to improve or modify product specifications as and when necessary, without prior notification. 1 . whether you require a 48 pole. there’s sure to be a hager enclosure to suit your application. electrical contractors and house builders. IP56 rated panelboard or a 24 pole. With pre-configured and configurable variants available. flush mounted loadcentre. So.Energy distribution Loadcentres All hager loadcentres have been developed with a strong aesthetic design integrating unique features as a result of feedback from homeowners. choice comes as standard. 6 D.4 D.5 D.1 GD surface mounted enclosures VM plastic enclosures GT plastic enclosures VT metal enclosures Golf plastic enclosures Vega plastic enclosures Vector plastic enclosures Automation enclosures Vega D accessories Package enclosures .12 D.15 Loadcentres D.2 D.7 D.13 D.14 D.8 D.Guide to the hager enclosure system D.11 D. Guide to the hager enclosure system Villas / Townhouse Residence Mini Gamma Series VM Series 1-4 I Free standing Residence GT Series 6-10 I Commercial Residence Vega Series 18-72 I IP30 Page D.5 D.8 Page D.11 Jyka 250 18-72 pole IP42 Page E.168 I Page D.3 Jyka IP 18-72 pole IP56 Page E.8 Vega D Series 96 .12 Page D.2 .flush Mini Gamma Series IP40 Page D.10 Vega Series 18-72 I IP41 Page D.6 Golf 4-36 I flush/surface Page D.4 Page D.11 Page D.11 Golf VC 18-54 I .12 Jyka IP 18-72 pole IP66 Page E.4 Golf 4-36 I flush/surface Vega Series 18-72 I Page D.5 Page D.5 Vector Series 36-36 I Vector Series 36-36 I IP65 Page D.13 Page D. 2 Golf VC 18-54 I .flush / surface Jyka XL 24-48 pole Page D.168 I Page D.3 Jyka IP 18-72 pole Page E.7 Page E.5 Vector Series 36-36 I Page E.10 Vega D Series 96 .5 Page E.12 Jyka IP 18-72 pole Page E.3 Jyka IP 18-72 pole Page E.168 I Vega Series 18-72 I Vega D Series 96 .5 D.Commercial Office / Retail VT Series 9-48 I .8 Vega Series 18-72 I Page D.3 Loadcentres .11 Jyka 250 18-72 pole Page D.7 Golf 4-36 I flush/surface Page E.5 Vector Series 36-36 I Page D.flush Page D.flush / surface Jyka XL 24-48 pole Industrial Complex VT Series 9-48 I .2 Page D.12 Jyka IP 18-72 pole Page D.13 Page E.13 Page D.11 Jyka 250 18-72 pole Page D. GD surface mounted enclosures IP30 Mini Gamma 1 row enclosure for 2 to 10I surface mounted with a rigid chassis housing.facility for cover to be sealed. . 2I width in I 17. 4I 4 GD104T GD104T 1 row. 10I c/.5mm 2 cat ref.key lock .opaque or transparent doors .earth / neutral links 1 row.pole fillers .cover fixed by quarter turn screws . . 6I 6 GD106T 1 row. GD102T 1 row.IP40 with door installed Options: .JP011 . . a 47mm DIN rail.earth / neutral links Accessories opaque doors 8 GD108T 10 GD110T GP106P suits suits suits suits suits GD102T GD104T GD106T GD108T GD110T GP102P GP104P GP106P GP108P GP110P transparent doors GP110T suits suits suits suits suits GD102T GD104T GD106T GD108T GD110T GP102T GP104T GP106T GP108T GP110T VZ313 VZ312 locking kit spare keys VZ313 Technical information A references row 1 1 1 1 1 GD102T GD104T GD106T GD108T GD110T enclosure size width height depth A B C 55 160 75 110 180 75 148 180 75 182 180 75 218 180 75 B D.for technical details refer to hager B&R description 1 row.4 Subject to technical change. 8I c/. PF6TR .cover fixed by screws . 2I 2 VM02C 1 row. 1I 1 VM01C 1 row. .VM surface mounted enclosures IP30 Series VM 1 row covers for 1 to 4I monobloc chassis and cover of insulating material.5mm cat ref. Options: .colour: RAL9001 .facility to be sealed . D.Pole fillers JP011.5 Loadcentres width in I 17. Fixed DIN rail for devices of a shoulder measurement of 47mm. 4I 3-4 VM04C VM01C VM04C Technical information 42 A references 153 B row VM01C VM02C VM04C 1 1 1 width A 23 40 82 enclosure size height B 155 155 155 depth C 65 65 65 Subject to technical change.for technical details refer to hager B&R description 1 row. GT06A 1 row.transparent door suits GT12A . PF6TR .colour: RAL9001 .Pole fillers JP011.5mm 6 cat ref.opaque door suits GT09A .forked busbar . . 12I x4 12 GT12A 1 row. 9I x3 9 GT09A 1 row. 18I x6 18 GT18A 1 row.doors .transparent door suits GT18A . 6I x2 1 row.supplied with: .opaque door suits GT06A .opaque door suits GT18A .6 Subject to technical change.circuit ID labels .transparent door GP06P GP06T GP09P GP09T GP12P GP12T GP18P GP18T GT09A Technical information references row 1 1 1 1 1 1 enclosure size width height depth A B C 134 210 100 188 210 100 242 210 100 350 210 100 250 140 65 250 140 65 A B GT06A GT09A GT12A GT18A GD10 GD1OLN B A D D. 10I x5 10 GD10 GT06A doors to suit suits GT06A .GT surface mounted enclosures IP41 Series GT 1 row enclosures for 6 to 18I This enclosure range is designed with ample wiring room and a separate soft fireproof back for easy entry of cables Options: .transparent door suits GT09A .links .for technical details refer to hager B&R description pole fillers width in I 17.opaque door suits GT12A . flush mount rows. flush mount x3 x4 x6 x8 x 12 x 16 x x x x x x 3 4 6 8 12 16 9 12 18 24 36 48 9 12 18 24 36 48 VT09S VT12S VT18S VT24S VT36S VT48S VT09F VT12F VT18F VT24F VT36F VT48F VT24S doors optional extra .with easy knockout for additional lock suits suits suits suits suits suits VT09S.5mm cat ref.circuit ID labels . surface mount rows. PF6TR . surface mount row.forked busbar . VT12S. flush mount row. surface mount rows.supplied with: . Options: .for technical details refer to hager B&R description pole fillers 1 1 1 2 3 4 1 1 1 2 3 4 row. VT18S. .0mm zinc anneal . surface mount rows.doors . VT09F VT12F VT18F VT24F VT36F VT48F VT041 VT042 VT043 VT044 VT045 VT046 VT24F lock optional extra .VT metal surface and flush mounted enclosures IP30 Series VT 1 to 4 rows for 9 to 48I this range of enclosures has been designed for applications that require a robust construction.7 Loadcentres width in I 17. flush mount rows.key locks .links . surface mount row. VT36S. VT24S. D. VT48S. flush mount rows.Pole fillers JP011.material: 1.Key lock suits all VT series enclosures LCLK Technical information VT Surface references A enclosure sizes width A 254 304 412 364 364 460 height B 245 254 254 414 604 745 depth 71 71 71 71 71 71 *Door = 22mm row VT09S VT12S VT18S VT24S VT36S VT48S 1 1 1 2 3 4 B A VT Flush references *Door = 22mm VT09F VT12F VT18F VT24F VT36F VT48F row 1 1 1 2 3 4 width 254 304 412 362 364 460 enclosure sizes wall box escutcheon height depth width height 245 62 304 304 254 62 354 304 254 62 462 304 414 62 414 464 604 62 414 654 745 62 514 799 B Subject to technical change. flush mount row. surface mount row.colour: RAL9016 . Pole fillers JP011 . x1 12 VS12PT VS12TT 2 row opaque transparent x 8.Golf surface mounted enclosures IP41 IP41 surface mounted enclosures 1 to 3 rows. x1 8 VS08PT VS08TT VS04PT 1 row opaque transparent x 4..circuit ID labels .supplied with: . x2 24 VS24PT VS24TT VS12PT 3 row opaque transparent x 12. x2 36 VS36PT VS36TT keylock to suit all golf enclosures VZ311 VZ311 Technical information A D VS04. Options: .keylock ..colour: RAL9010 . Distance between rails 125mm. x2 VS04PT VS04TT 1 row opaque transparent x 2.forked busbar . Enclosures are of an insulating material coloured RAL9010. VS36.links (63A rated) . 4 to 36 modules. Reversible door opening 1800. E 1 1 1 2 3 row 4 row 8 row 12 rows 12 rows 12 dimension (mm) A B D 130 180 84 200 275 275 275 180 225 350 500 84 95 95 95 fixing E 90 120 205 205 205 F 140 140 160 285 410 B D. VS12..8 Subject to technical change.. F . VS24. Fixed DIN rail for devices of a maximum shoulder measurement of 47mm..for technical details refer to hager B&R description 1 row opaque transparent pole fillers width in I 17.5mm 4 cat ref. between rails 125 VS08. VF24.links (63A rated) .keylock .5mm cat ref. Distance between rails 125mm reversible door opening 1800. x1 VF12PT x 8. VF36.Golf flush mounted enclosures IP41 IP41 flush mounted enclosures 1 to 3 rows. Options: .. D..forked busbar .supplied with: .Pole fillers JP011 . Fixed DIN rail for devices of a maximum shoulder measurement of 47mm.IP 41 . VF12. . x1 x 4.for technical details refer to hager B&R description 1 row opaque transparent 1 row opaque transparent 1 row opaque transparent 2 row opaque transparent 3 row opaque transparent keylock to suit all golf enclosures pole fillers x2 4 VF04PT VF04TT 8 VF08PT VF08TT 12 VF12PT VF12TT 24 VF24PT VF24TT 36 VF36PT VF36TT VZ311 x 2. x2 earthed metal back plate to suit 12 pole VFBP12 VF24PT earthed metal back plate to suit 24 pole VFBP24 Technical information A D references VF04.. E C 1 1 1 2 3 row 4 row 8 row 12 rows 24 rows 36 A 162 250 322 322 322 dimension (mm) B C 220 73 230 265 390 535 67 70 70 70 D 90 94 97 97 97 wall box E F 122 177 209 281 281 281 189 224 349 491 Subject to technical change. x2 x 12. between rails 125 B F VF08. 4 to 36 modules.colour: RAL9010 ...circuit ID labels .9 Loadcentres width in I 17. Enclosures are of an insulating material coloured RAL9010. Golf flush mounted enclosures IP41 IP41 flush mounting enclosures 1 to 3 rows. VC18PT VC18TT x7 x1 opaque transparent VC18PT 2 row x 14 x2 36 opaque transparent VC36PT VC36TT 3 row x 21 x3 54 opaque transparent VC54PT VC54TT keylock to suit all golf enclosures earthed metal back plate to suit 18 pole VZ311 VCBP18 VC36TT VZ311 Technical information B B T D H H 150 E references row 1 1 2 2 3 3 cut-out H 295 295 445 445 595 595 sizes B 390 390 390 390 390 390 VC18PT VC18TT VC36PT VC36TT VC54PT VC54TT 18 18 36 36 54 54 dimensions (mm) enclosure H B T 335 430 70 335 430 70 485 430 70 485 430 70 635 430 70 635 430 70 D 74 74 74 74 74 74 E 13 13 13 13 13 13 D. Reversible door opening 180 o Supplied with: . Enclosures are of an insulating material coloured RAL 9010.links .for technical details refer to hager B&R description 1 row characteristics width in I 17.circuit ID labels . . 18 to 54 modules.10 Subject to technical change.busbar .pole fillers .5mm 18 door cat ref. Adjustable DIN rail for devices of a maximum shoulder measurement of 47mm. x 2 36 VB36PT VB36TT VB18PT 3 row opaque transparent x 12.5mm cat ref.forked busbar .Pole fillers JP011 .links . x3 54 VB54PT VB54TT 4 row opaque transparent x 16. The door is also reversible with an integral flush handle. The enclosures feature a removable chassis with DIN rails for ease of installation. 1 to 4 rows. x4 72 VB72PT VB72TT keylock for transparent or opaque doors supplied with 2 keys VZ310 VB36TT Technical information A 150 150 135 references fixing VB18 VB36 VB54 VB72 A 370 370 370 370 B 300 450 600 750 dimension(mm) E 300 300 300 300 F 236 386 536 686 G 32 32 32 32 H F E G 18 36 54 54 Subject to technical change. x1 8 VB18PT VB18TT 2 row opaque transparent x 8. .circuit ID labels . Options: .colour: RAL9010 .Vega surface mounted enclosures IP41 IP40 surface mounted enclosures with transparent or opaque doors.door lock .11 Loadcentres width in I 17. D. Enclosures are of an insulating material coloured RAL9010 white. Top and bottom cable entry plates are removable and interchangeable.for technical details refer to hager B&R description 1 row opaque transparent characteristics x 4.supplied with: . 18 to 72 modules. IP65 Surface mounted enclosures with transparent doors 1 to 2 rows.Vector enclosures .links . M32.transparent hinged door . VE106H 8+2 VE110H 12 VE112H VE212H 24 VE212H 18 VE118H 36 VE218H supplied with 2 keys VZ311 Technical information A 151 references VE106H VE110H VE112H VE212H VE118H VE218H 6 10 12 24 18 36 row 1 1 1 2 1 2 73.colour: RAL7035 . .5mm 4+2 cat ref.pole fillers .forked busbar . supplied with IP54 cable glands .adjustable DIN rail for shoulder measurement 47 and 63mm .2 lateral knockouts for cable entry .5 H 150 F 59 47.reversible door .5 E enclosure A 165 237 310 310 418 418 sizes B 190 210 302 427 302 452 fixing E 108 180 230 230 338 338 F 158 173 155 280 155 305 D.circuit ID labels .for technical details refer to hager B&R description 1 row supplied cable glands 2xM20 + 2xM25 + 1xM32 1 row supplied cable glands 4xM20 + 2xM25 + 1xM32 1 row supplied cable glands 10xM20 + 2xM25 + 1xM32 2 row supplied cable glands 14xM20 + 4xM25 + 1xM32 1 row supplied cable glands 14xM20 + 4xM25 + 1xM32 2 row supplied cable glands 8xM20 + 14xM25 + 1xM32 keylock width in I 17.JP010 .sealable cover .supplied with: .12 Subject to technical change. 6 to 36 I .premarked knock outs for bushes or cable glands M20. M25. M40 and M50. Jyka D and XLD.All 3D products conform to the various DIN and enclosure standard and are in modular rows of either 24 or 18 modules .3D solutions system . .The Jyka D has 4-6 rows of 24 modules (96 -144 ) while the XLD has 5 rows of 18 modules (90 ). . Modular Distribution Enclosures . Vega D.for technical details refer to hager B&R description characteristics height Vega D Surface without door w. while the Jyka D.The 3D System consists of three enclosure ranges. . 600mm x d. . . 560mm x d. . 550mm x d.Colour RAL 9002.An additional internal insulation guarantees class II isolation. 185mm 4 rows (96 ) 1x(5x25mm2 + 17x4mm2) 700mm FD42D 5 rows (120 ) 1 x (5x25mm2 +17x4mm2) 1 x (6x25mm2 + 20x4mm2) 6rows (144 ) 3 x (6x25mm2 + 20x4mm2) 850mm FD52D 1000mm FD62D FD52D 7 rows (168 ) 3 x (6x25mm2 + 20x4mm2) 1150mm FD72D Vega D Flush without door w. and XLD are surface mounted versions. 166mm 4 rows (96 ) 750mm JKD96 6 rows (144 ) 970mm JKD144 XLD Surface with door w.Vega D enclosures are configured from 4-7 rows of 24 modules (96 -168 ) They combine sheet metal and injected plastic so as to achieve a light yet strong enclosure.The Vega D is available in either surface or flush mounting configurations. 130mm 5 rows (90 ) 765mm XLD90 XLD90 D.13 Loadcentres cat ref. Jyka D & XLD enclosures . Each of the three ranges have been designed to complement the vast array of installations.automation enclosures Vega D.481mm x d. 152mm frame width 40mm 4 row (96 ) 1 x (5x25mm2 + 17x4mm2) 800mm FU42D 5 rows (120 ) 1 x (5x25mm2 + 17x4mm2) 1 x (6x25mm2 + 20x4mm2) 950mm FU52D FU72D 6 rows (144 ) 3 x (6x25mm2 + 20x4mm2) 1150mm FU62D 7 rows (168 ) 3x (6x25mm2 + 20x4mm2) 1350mm FU72D JKD144D Jyka D Surface with door w. c/.14 . Sheet metal and powder coated To suit FD42D or FU42D To suit FD52D or FU52D To suit FD62D or FU62D To suit FD72D or FU72D FD42P FD52P FD62P FD72P FZ497 * inclusion of door provides IP41 Locks To replace the standard lock Circuit schedule holder lock. To suit FD42D or FU42D To suit FD52D or FU52D To suit FD62D or FU62D To suit FD72D or FU72D FD42T FD52T FD62T FD72T FD52T FD52P Plain door reversible for surface and flush enclosures. key No.3mm hardened glass * inclusion of door provides IP41 characteristics cat ref. 1242E FZ497 FZ794 Terminals Universal support to mount terminal blocks KN00A KN00A Neutral terminal blocks terminal block terminal block terminal block terminal block terminal block terminal block 2x25mm2 3x25mm2 4x25mm2 5x25mm2 6x25mm2 8x4mm2 terminal 11x4mm2 terminal 14x4mm2 terminal 17x4mm2 terminal + 20x4mm2 terminal bridging clip x 10 + + + + 2x25mm2 3x25mm2 4x25mm2 5x25mm2 6x25mm2 + 8x4mm2 terminal + 11x4mm2 terminal + 14x4mm2 terminal + 17x4mm2 terminal + 20x4mm2 terminal KN10N KN14N KN18N KN22N KN26N KN99N KN22N Earth terminal blocks terminal block terminal terminal terminal terminal terminal block block block block block KN10E KN14E KN18E KN22E KN26E KN99E bridging clip x 10 2x25mm2 + 8x4mm2 terminal 3x25mm2 + 11x4mm2 terminal 4x25mm2 + 14x4mm2 terminal 5x25mm2 + 17x4mm2 terminal 6x25mm2 + 20x4mm2 terminal bridging clip x 10 UD22C2 Phase terminal blocks terminal block terminal terminal terminal terminal terminal block block block block block UZ01V1 UZ25V1 UZ25V2 KN10P KN14P KN18P KN22P KN26P KN99P Gear tray module (not suitable for flush enclosures) 415mm x 235mm UD22C2 Cable management accessories Cable management retainer (x20) large * Not suitable for flush enclosures (x20) small Cable management retainer Retainer support / exten arms (x20) Support arms for DIN rail / trunking DIN rail to suit Vega D UZ25V1 UZ50A1 UZ25V2 UZ01V1 (x2) UZ50A1 UZ38D1 VZ405 Mounting anchors (x4) for plaster walls to suit flush enclosures VZ405 D.Vega D accessories description Door options Transparent doors reversible for surface and flush enclosures. Sheet metal. powder coated. This range has been designed for ease of installation and ease of ordering. description ref JT201 2 pole RCCB complete with enclosure and 2 holes neutral link 30mA 40A 2 2 pole RCCB complete with enclosure 30mA 40A 2 JT202 JT202 2 pole RCCB complete with enclosure and 3 holes neutral link 30mA 63A 2 JT203 4 pole RCCB complete with enclosure 30mA 40A 4 JT204 4 pole RCCB complete with enclosure and 3 holes neutral link 30mA 40A 4 JT205 D.Package enclosures Description for applications where an RCCB is being added to an existing installation or where other DIN type fixing facilities are not available.15 Loadcentres residual current Irn current rating (A) width in I 17.5mm cat. To overcome this problem we present a range of RCCBs complete with DIN rail enclosures and where necessary an integral neutral link for up to three circuits. . Energy distribution Panelboards The Jyka series of panelboards are designed for ease of installation. . the XL. maximising internal space and presenting commercially required aesthetics. and IP ranges meet and surpass the growing demands of the industry. Series 2. Regardless of specifications. 3 E.Jyka XL series panelboards E.1 Panelboards .2 E.7 Jyka 250 series 2 panelboards Jyka IP series panelboards Jyka SS series panelboards E.5 E. . JK24XL JK36XL JK48XL JK16S/C JK20S JK48XL extension box complete with 18 modules of DIN space flush surround to suit JK24XL to suit JK36XL to suit JK48XL polefillers 6 pole chassis finger cap (10 pack) chassis shroud caps (2 pack) PF6TR JK90B JK91B JKFL1/XL JKFL2/XL JKFL3/XL JK00XL Technical information D cat.1.2 Subject to technical change.type tested busbar .6mm construction . ref. JK24XL JK36XL JK48XL extension box JK00XL dimensions height H width W depth D 658 481 130 765 481 130 872 481 130 350 481 130 H W E.neutral and earthbar .1 lockable door circuit schedule card separate escutcheon & door Australian made for technical details refer to hager B&R NEW IMPROVED CHASSIS .extra moulding on chassis shoulders provides a positive alignment point for the breakers and the escutcheon cutout. .Jyka XL series panelboards The Jyka XL series of panelboards are the recommended solution when both installation and economic constraints arise .AS/NZS3439.push the breaker into the chassis until it stops then tighten to guarantee correct alignment description 24 way panelboard 36 way panelboard 48 way panelboard incoming devices loadbreak switch 160A 3 pole DIN rail mounted loadbreak switch & connection kit loadbreak switch 200A 3 pole DIN rail mounted loadbreak switch & connection kit accessories cat ref.colour: RAL9002 .18 poles DIN standard .removable gland plates . extra moulding on chassis shoulders provides a positive alignment point for the breakers and the escutcheon cutout. JKS18P JKS24P JKS30P JKS36P JKS42P JKS48P JKS60P JKS72P incoming devices connection kits .removable gland plates . .custom lock options .including 160A 3 pole loadbreak switch & 200A 3 pole loadbreak switch & 225A 3 pole loadbreak switch & 250A 3 pole loadbreak switch & switchgear connection kit connection kit connection kit connection kit JK11S JK12S JK15S JK16S/C JK20S JKS22S/B JKS25S JKS36P outgoing devices connection kit . the Jyka 250 series of panelboards is recommended for internal commercial applications.colour: RAL9002 .6mm construction .type tested busbar .AS/NZS3439. includes cable & hardware for 80/100A MCB’s in the top centre includes busbar & hardware connection kits .push the breaker into the chassis until it stops then tighten to guarantee correct alignment description 18 24 30 36 42 48 60 72 way way way way way way way way panelboard panelboard panelboard panelboard panelboard panelboard panelboard panelboard cat ref. E.separate hinged escutcheon and door . .circuit schedule card .1. includes cable & hardware JK15K Technical information dimensions D cat.custom built options .3 Panelboards . excluding switchgear for 160A 3 pole MCCB in the lower position.Jyka 250 series 2 panelboards Designed for ease of installation and maximising internal space while presenting commercially required aesthetics.Australian made .reversible door .kit only.neutral and earthbar . ref. excluding switchgear JKS18P for 250A MCCB in the top centre position c/.cable tie anchors . JKS18P JKS24P JKS30P JKS36P JKS42P height H 750 750 860 860 970 970 1200 1200 350 width W 560 560 560 560 560 560 560 560 560 depth D 166 166 166 166 166 166 166 166 166 H JKS48P JKS60P JKS72P extension box JKS00E W Subject to technical change.removable mounting pan .kits only.cable zone enclosure JK16K for 80/100A ‘SB’ switches (SB380/SB399) in the top centre position for 80/100A MCB in the lower left & right position.1 .IP42 .for technical details refer to hager B&R NEW IMPROVED CHASSIS .lockable door . JKS02E & JKS03E JKS00E joining plate For joining 2 Jyka panels together extension box mounting kits to suit 18 modules of DIN to suit LT052 fuse carrier .250A cable zone top mount to suit 36 modules of DIN flush surrounds to suit JKS18P and JKS24P to suit JKS30P and JKS36P to suit JKS42P and JKS48P to suit JKS60P and JKS72P fuse carriers fuse carrier to suit size 00/160A DIN blade fuses fuse carrier to suit size 1/250A DIN blade fuses fuse carrier to suit size 2/400A DIN blade fuses cable clamps to suit LT052 (6-70mm2) cable clamp to suit LT150 (70-150mm2) cable clamps to suit LT250 (120 .2sec 10kA 1.160A to suit LT150 fuse carrier .240mm2) JK/GP JKS01E JKS02E JKS05E JKS06E JKS07E JKSFL1 JKSFL2 JKSFL3 JKSFL4 LT052 LT150 LT250 LZ051 LZ151 LZ152 LT052 DIN blade fuses available on request chassis 18 way double-ended 24 way double-ended 30 way double-ended 36 way double-ended 42 way double-ended 48 way double-ended 60 way double-ended 72 way double-ended 18 way single-ended 24 way single-ended 36 way single-ended 48 way single-ended chassis rating 250A 250A rated short time 18kA 0. 2 pack JK90B JK91B PF6TR cat ref.0sec peak withstand current 36kA 17kA JK18C JK24C JK30C JK36C JK42C JK48C JK60C JK72C JK18C1 JK24C1 JK36C1 JK48C1 E.4 . 10 pack chassis shroud caps.Jyka 250 series 2 panelboards description accessories for Jyka 250 series pole fillers 6 pole chassis caps & shrouds chassis finger cap. PF6TR extension box empty enclosure to house mounting kits JKS01E. IP56 (IP66 available upon request) .AS/NZS3439.including 160A 3 pole loadbreak switch & 200A 3 pole loadbreak switch & 225A 3 pole loadbreak switch & 250A 3 pole loadbreak switch & outgoing devices connection kit .lockable door .Australian made . ref. JK18IP JK24IP JK30IP JK36IP JK42IP JK48IP JK60IP JK72IP $ ex-GST $ incl-GST incoming devices JK24IP connection kits .cable tie anchors .6mm construction .1.kits only.1 . JK18IP JK24IP JK30IP JK36IP JK42IP JK48IP JK60IP JK72IP extension box JKE/IP JK2IE/IP height 750 750 860 860 970 970 1200 1200 350 350 width 600 600 600 600 600 600 600 600 600 600 depth 250 250 250 250 250 250 250 250 250 250 0 9 Subject to technical change. E.custom lock options NEW IMPROVED CHASSIS .circuit schedule card . dimensions cat. includes cable & hardware JK15K switchgear connection kit connection kit connection kit connection kit JK17K JK11S JK12S JK15S JK16S/C JK20S JKS22S/B JKS25S Technical information .Jyka IP series panelboards Designed and constructed for use in locations that require the highest levels of protection from the surrounding environment. .neutral and earthbar .push the breaker into the chassis until it stops then tighten to guarantee correct alignment .for technical details refer to hager B&R description 18 24 30 36 42 48 60 72 way way way way way way way way panelboard panelboard panelboard panelboard panelboard panelboard panelboard panelboard cat ref.extra moulding on chassis shoulders provides a positive alignment point for the breakers and the escutcheon cutout.separate hinged escutcheon and door . includes cable & hardware for 80/100A MCB’s in the top centre includes busbar & hardware connection kits .type tested busbar .custom built options .colour: RAL9002 . excluding switchgear for 250A MCCB in the top centre position for 80/100A ‘SB’ switches in the top centre position for SB380 + SB390 in the lower position.kit only. .5 Panelboards .removable gland plates . excluding switchgear for 160A 3 pole MCCB in the lower position. 6 .2sec 10kA 1.5 modules flush surrounds to suit JK18IP and JK24IP to suit JK30IP and JK36IP to suit JK42IP and JK48IP to suit JK60IP and JK72IP fuse carriers fuse carrier to suit size 00/160A DIN blade fuses fuse carrier to suit size 1/250A DIN blade fuses fuse carrier to suit size 2/400A DIN blade fuses cable clamps to suit LT052 (6-70mm2) cable clamp to suit LT150 (70-150mm2) cable clamps to suit LT250 (120 .240mm2) DIN blade fuses available on request chassis 18 way double-ended 24 way double-ended 30 way double-ended 36 way double-ended 42 way double-ended 48 way double-ended 60 way double-ended 72 way double-ended 18 way single-ended 24 way single-ended 36 way single-ended 48 way single-ended chassis rating 250A 250A rated short time 18kA 0. 10 pack chassis shroud caps.Jyka IP series panelboards description accessories for Jyka IP series pole fillers 6 pole chassis caps & shrouds chassis finger cap. 2 pack extension box complete with blank escutcheon & mounting pan (refer mounting kits) complete with 21 modules of DIN space JK21E/IP JKE/IP JK90B JK91B PF6TR cat ref. PF6TR mounting kits DIN rail kit 4.0sec withstand current 36kA 17kA JK18C JK24C JK30C JK36C JK42C JK48C JK60C JK72C JK18C1 JK24C1 JK36C1 JK48C1 LT052 LT150 LT250 LZ051 LZ151 LZ152 JKFL1/IP JKFL2/IP JKFL3/IP JKFL4/IP JK16A LT052 E. type tested 250A chassis .contact us for custom requirements NEW IMPROVED CHASSIS .for technical details refer to hager B&R description 24 36 48 72 way way way way stainless stainless stainless stainless steel steel steel steel panelboard panelboard panelboard panelboard cat ref.IP66 rated .neutral & earth bars . unpainted N4 finish .stainless steel top & bottom gland plates .kits only.extra moulding on chassis shoulders provides a positive alignment point for the breakers and the escutcheon cutout.6mm zincanneal . JK18IP JK24IP JK30IP JK36IP JK42IP JK48IP JK60IP JK72IP dimensions height width 750 600 750 600 860 600 860 600 970 600 970 600 1200 600 1200 600 depth 250 250 250 250 250 250 250 250 0 Subject to technical change. excluding switchgear for 160A 3 pole MCCB in the lower position.internals from 1. ref.5mm 316 grade stainless steel.turnbuckle style door locks .kit only.7 JK24IP connection kits . excluding switchgear for 250A MCCB in the top centre position for 80/100A ‘SB’ switches in the top centre position for SB380 + SB390 in the lower position.enclosure body from 1.hinged & painted internal escutcheon (zinc anneal) . includes cable & hardware JK15K Technical information .including 160A 3 pole loadbreak switch & 200A 3 pole loadbreak switch & 225A 3 pole loadbreak switch & 250A 3 pole loadbreak switch & outgoing devices switchgear connection kit connection kit connection kit connection kit JK16S/C JK20S JKS22S/B JKS25S connection kit .Jyka SS series panelboards Designed & constructed for use in corrosive environments or improved aesthetics . 9 cat. includes cable & hardware for 80/100A MCB’s in the top centre includes busbar & hardware JK17K JK11S JK12S JK15S Panelboards E. . .schedule card & holder .push the breaker into the chassis until it stops then tighten to guarantee correct alignment . JK24IP/S JK36IP/S JK48IP/S JK72IP/S incoming devices connection kits . 8 . E. protection and distribution of low voltage installations.Energy distribution Main incomers This section includes moulded case circuit breakers and load break switches which are utilised to ensure the switching. 1 Main incomers .Moulded case circuit breakers F.11 F.13 Technical information for circuit breakers Prospective fault current Load break switches Load break switches .9 F.10 F.2 F.characteristics F. 40kA MCCB MCCB MCCB MCCB MCCB MCCB 25 40 63 80 100 125 HN143 HN145 HN147 HN148 HN149 HN150 25.8 .25kA MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 16 20 25 32 40 50 63 80 100 125 HH101 HH102 HH103 HH104 HH105 HH106 HH107 HH108 HH109 HH110 HH143 HH145 HH147 HH148 HH149 HH150 HH147 76 25. switchboard builders and OEM’s.1 x In magnetic setting fixed at 10-20xIn Un 240/415V~ 240/415V~ 240/415V~ 240/415V~ Ui 500V 500V 500V 500V description current rating (A) poles 1 poles 3 frame: H125H.flexible frame h125h h160h h125n h125e Icu 25kA 25kA 40kA 70kA approvals and tests .4 frame: H160H 25kA MCCB 97 140 160 - HH151 frame: H125N . and 3 poles with breaking capacities including 25kA.Moulded case circuit breakers h125 and h160xs description Hager MCCB’s offer contractors. 230V/6A 1 NO/NC + 1NO/NC 230V/6A c/w: 200mm shaft cat ref. technical data .Connection capacity h125: 95mm2 .2 .60V~ 208V .rigid h125: 50mm2 .4 25.flexible h160xs: 95mm2 .70kA MCCB MCCB MCCB MCCB MCCB MCCB 25 40 63 80 100 125 HE143 HE145 HE147 HE148 HE149 HE150 45 70 accessories and auxiliaries description shunt trip shunt trip shunt trip undervoltage release undervoltage release undervoltage release auxiliary switch auxiliary switch aux / alarm switch rotary handle locking kit interphase barrier terminal cover characteristics 24V .IEC60947-2 thermal setting 0.240V~ 380V . a wide choice of options.240V~ 380V . 230V/6A 2 NO/NC.AS3947-2 .600V~ 48V . The range is available in 1.500V~ 1 NO/NC. HX101E HX104E HX105E HX111E HX114E HX115E HX121 HX122 HX123 HX131A HX139 HY119 HY121 HY121 F.rigid h160xs: 75mm2 . 40kA and 70kA.4 90 75 frame: H125E .60V~ 110V . 60V~ 110V .flexible . technical data approvals and tests .10 x In .electronic trip unit thermal setting 0. switchboard builders and OEM’s. a wide choice of options.1 x In magnetic setting 2 .1.240V~ 380V . 230V/6A 2 NO/NC.70kA electronic trip unit 250 HE205 accessories and auxiliaries description 104.14 x In delay setting 0 . 230V/6A 1 NO/NC + 1NO/NC 230V/6A cat.AS3947-2 .40kA electromechanical trip unit electromechanical trip unit electromechanical trip unit electronic trip unit 160 200 250 250 HN254 HN203 HN204 HN205 HN204 frame : h250e .60V~ 208V .rigid : 185mm2 .0 x In magnetic setting 5 . The range. h250 is available in 3 pole with breaking capacities including 40kA and 70kA.Moulded case circuit breakers h250 description Hager MCCB’s offer contractors.4 .8 .3 Main incomers .electromechanical trip unit thermal setting 0.Connection capacity : 185mm2 .185mm2 HY201 HY212 F.300ms frame h250n h250e Icu 40kA 70kA Un 400V~ 400V~ Ui 690V 690V description current rating (A) poles 3 frame : h250n .240V~ 380V .500V~ 1 NO/NC.IEC60947-2 . ref HX101E HX104E HX105E HX111E HX114E HX115E HX121 HX122 HX223E shunt trip shunt trip shunt trip 139 178 undervoltage release undervoltage release undervoltage release 35 auxiliary switch auxiliary switch 110 96 aux / alarm switch 100 rotary handle rotary handle locking kit c/w: 200mm shaft mounted on device HX231 HX230 HX239 HY219 HY221 87 interphase barrier terminal cover cable connection terminals busbar extensions 25 .600V~ 48V .8 35 35 characteristics 24V . 2 24V .8 .70kA electronic trip unit 400 HE305E accessories and auxiliaries description 139.2 43.14 x In delay setting 0 .0 x In magnetic setting 5 .7 auxiliary switch auxiliary switch aux / alarm switch 136 100 rotary handle rotary handle 100 mounted on device c/w: 200mm shaft HX330E HX331E HX339E HY719 HY321E locking kit interphase barrier terminal cover cable connection terminals cable connection twin terminals bus bar extensions 35 .300ms frame h400n h400e Icu 50kA 70kA Un 400V~ 400V~ Ui 750V 750V description current rating(A) poles 3 frame : h400n .Moulded case circuit breakers h400xs description Hager MCCB’s offer contractors. The range. a wide choice of options. switchboard builders and OEM’s.5 257.1.4 .4 . h400xs is available in 3 pole with breaking capacities including 50kA and 70kA.rigid : 195mm2 .AS3947-2 .electronic trip unit thermal setting 0.7 43.240V~ 380V . ref HX101E HX104E HX105E HX111E HX114E HX115E HX121 HX122 HX223E shunt trip shunt trip shunt trip 214.240V~ 380V 600V~ 48V .flexible . 230V/6A 2 NO/NC.60V~ 208V .50kA electromechanical trip unit electromechanical trip unit electronic trip unit 320 400 400 HN302E HN303E HN305E HN303E frame : h400e .Connection capacity : 240mm2 .240mm2 spreaders HY301E HY303E HY312E F.1 x In magnetic setting 2 .500V~ 1 NO/NC. 230V/6A 1 NO/NC + 1NO/NC 230V/6A undervoltage release undervoltage release undervoltage release 43.7 characteristics cat. technical data approvals and tests .electromechanical trip unit thermal setting 0.240mm2 35 .IEC60947-2 .10 x In .60V~ 110V . 300ms frame h630n h630e Icu 50kA 70kA Un 400V~ 400V~ Ui 750V 750V description current rating (A) poles 3 frame : h630n .7 shunt trip shunt trip shunt trip 214.10 x In .2 43.flexible .1 x In magnetic setting 2 .60V~ 110V .IEC60947-2 .240V~ 380V 600V~ 48V . The range.5 257 2 24V .1. ref HX101E HX104E HX105E HX111E HX114E HX115E HX121 HX122 HX223E 139.240mm2 35 .AS3947-2 .5 description characteristics cat.8 .Moulded case circuit breakers h630xs description Hager MCCB’s offer contractors.rigid : 195mm2 . 230V/6A 1 NO/NC + 1NO/NC 230V/6A undervoltage release undervoltage release undervoltage release 43.240mm2 spreaders HY301E HY303E HY312E . 230V/6A 2 NO/NC. technical data approvals and tests . h630xs is available in 3 pole with breaking capacities including 50kA and 70kA.60V~ 208V .4 .7 auxiliary switch auxiliary switch aux / alarm switch 136 100 rotary handle rotary handle 100 mounted on device c/w: 200mm shaft HX330E HX331E HX339E HY719 HY321E locking kit interphase barrier terminal cover cable connection terminals cable connection twin terminals bus bar extensions 35 .500V~ 1 NO/NC. switchboard builders and OEM’s.240V~ 380V .14 x In delay setting 0 .electromechanical trip unit thermal setting 0. a wide choice of options.Connection capacity : 240mm2 .7 43.0 x In magnetic setting 5 .70kA electromechanical trip unit 630 HE355E accessories and auxiliaries Main incomers F.electronic trip unit thermal setting 0.50kA electromechanical trip unit electromechanical trip unit electronic trip unit 500 630 630 HN352E HN353E HN355E HN353E frame : h630e . IEC60947-2 .500V~ HX815 rotary handle 200mm shaft rotary handle handle c/w: HX831 mounted on device HX830 interphase barriers HY819 terminal kit 2 X 185 .6 .50kA electronic trip unit 800 HN806 HN806 accessories and auxiliaries description characteristics cat.4 242 273 1 x N/O-N/C . a wide choice of options.electronic trip unit thermal setting 0.Moulded case circuit breakers h800xs description Hager MCCB’s offer contractors. ref HX821 209.Connection capacity : 240mm2 .1 x In magnetic setting 2 .240mm 2 HY801 padlockable handle kit HY850 F. switchboard builders and OEM’s.6 70 auxiliary switch 2 x N/O -2 x N/C 230V/6A~ alarm/auxiliary switch 406. The h800 is available in 3 pole with breaking capacities including 50KA.flexible frame h800n Icu 50kA .440V~ HX804 undervoltage release 70 70 208V .300ms Un 400V~ Ui 750V description current rating (A) poles 3 frame : h800n . technical data approvals and tests .AS3947-2 .5 .240V~ HX814 undervoltage release 380V .1 x NO-N/C 230V/6A~ HX822 shunt trip 110V .rigid : 195mm2 .8 x In delay setting 0 . switchboard builders and OEM’s.Connection capacity : 240mm2 .440V~ HX905 undervoltage release 208V .4 1 x N/O-N/C .240V~ HX914 undervoltage release 380V .1 x In magnetic setting 2 .1 x NO-N/C 230V/6A HX922 373 shunt trip 110V .rigid : 195mm2 . h1250xs is available in 3 pole with breaking capacities including 50kA and 70kA.7 description characteristics cat.AS3947-2 .Moulded case circuit breakers h1250xs description Hager MCCB’s offer contractors. ref HX921 209. a wide choice of options.240V~ HX904 shunt trip 70 70 380V .6 70 auxiliary switch 2 pole 2 x N/O-2 x N/C 230V/6A alarm/auxiliary switch 406.70kA electronic trip unit 1250 HN903 1250 HE903 HN903 accessories and auxiliaries Main incomers F. technical data approvals and tests .500V~ HX915 rotary handle mounted on device HX930 rotary handle c/w 200mm shaft HX931 interphase barriers HY919 busbar extension HY910 .8 x In delay setting 0300ms Un 400V~ 400V~ Ui 750V 750V description current rating (A) poles 3 frame : h1250n .IEC60947-2 .electronic trip unit thermal setting 0.flexible frame h1250n h1250e Icu 50kA 70kA . The range.5 .50kA electronic trip unit frame : h1250e . 240V~ HX914 undervoltage release 380V . The range.5 .1 x In magnetic setting 2 .4 373 1 x N/O-N/C .8 .Connection capacity supplied with rear connection bars frame h1600n Icu 50kA .IEC60947-2 .50kA electronic trip unit current rating (A) poles 3 1600 HN904 HN904 accessories and auxiliaries description 209.electronic trip unit thermal setting 0.Moulded case circuit breakers h1600xs description Hager MCCB’s offer contractors.8 x In delay setting 0300ms Un 400V~ Ui 750V description frame : h1600n . h1600xs is available in 3 pole with breaking capacities including 50kA.500V~ HX915 rotary handle mounted on device HX930 rotary handle c/w 200mm shaft HX931 interphase barriers HY919 busbar extension HY910 F. ref HX921 auxiliary switch 2 pole 2 x N/O-2 x N/C 230V/6A alarm/auxiliary switch 406.240V~ HX904 shunt trip 70 70 380V .AS3947-2 .1 x NO-N/C 230V/6A HX922 shunt trip 110V . technical data approvals and tests . switchboard builders and OEM’s.440V~ HX905 undervoltage release 208V . a wide choice of options.6 70 characteristics cat. 5 2. NDNxxxA range).37 0.74 0. and it’s affect on the choice of conductor and circuit breaker for a given circuit. An earth fault situation is caused when an active conductor comes into contact with an earthed conductor .5 2.44 1.3) To make sure that this fault current is large enough to trip a circuit breaker in the required time the fault loop impedance (Zs) must be below a certain value If Zs is too large then the circuit breaker may take too long to trip(> 0. Using these tables will help ensure that the disconnection time for a 230V a.91 0.15 Max Zs ( ) for all ranges 5 secs 57.4s) or may not trip at all.17 TABLE 2 Maximum circuit length (MCL) and maximum circuit impedance (Zs) for hager MCBs (NSxxx range.15 0.5 2.77 0.29 0. fault loop impedance. Thermal and magnetic settings of a circuit breaker – hager circuit breakers have both rated current and magnetic characteristics.80 1.5 4 4 6 6 10 10 16 16 25 25 35 35 50 Earth mm2 1 1 1 1 1 1 1.23 0. So a circuit breaker with a magnetic setting of 14 x In will require more energy to trip it (in the required time) than a circuit breaker with a magnetic setting of 7. Voltage drop and overcurrent requirements should also be given consideration.Technical information for circuit breakers fault loop impedance With the introduction of AS/NZS 3000:2007 there are new wiring rules for electrical contractors and electrical consultants to consider when designing an electrical installation.fault current then flows.5 2. So circuit length. The higher the rated current and magnetic settings.5 1.59 2.15 1.5 2.58 0.5 x In. This guide is only concerned with one new area.96 0.4s for socket–outlets up to 63A.72 0. cross sectional area of the cable and circuit breaker settings all need to be taken into account to ensure correct function of a circuit.67 5.96 0.38 0. the higher it’s impedance per meter will be. short-circuit is formed and fault current flows.58 5.23 0.4 secs 3.5 2.33 10.07 3.30 1. conductor size Active mm2 1 1 1 1 1 1 1.15 0.31 0.38 0.07 1.5.07 1.Curve MCBs MCL (m) 545 273 182 136 91 55 82 51 85 68 67 52 60 48 78 62 76 59 66 53 85 68 106 Max Zs ( ) 0.9 .59 3.5 2.46 0.58 0.53 1.58 0.58 0.75 3.18 0.92 1.23 0. the more energy is required to trip the circuit breaker in the required time (< 0. NCNxxxA range. hager MCB range D Curve MCBs MCL (m) 55 33 49 31 51 41 40 31 36 29 47 37 45 36 40 32 51 41 63 Max Zs ( ) 0.50 28.4 s ).77 0.46 Main incomers 19.46 0.5 4 4 6 6 6 6 10 10 16 Protective device rating a 1 2 3 4 6 10 10 16 16 20 25 32 32 40 40 50 63 80 80 100 100 125 125 C. Where: MCL = Maximum circuit length Zs = Maximum circuit impedance Above table based on supply of voltage of 230V / 400V ( AS/NZS 3000: 2000 Amdt1) Subject to technical changes F.88 2. The tables below are a guide to the maximum circuit length and maximum circuit impedance for a given hager circuit breaker. NTxxxC range.44 1.61 0.15 0. If this is not possible then installing a hager RCD will provide a simple and economical solution. If more energy is required to flow.5.80 1.18 0. or handheld Class 1 equipment intended for manual movement during use.67 15. Contractors and consultants must make sure that the conductors in a circuit will allow sufficient energy to flow to cause the circuit breaker to trip in the required time (disconnection time for 230V supply is 0.25 0.49 0.92 1. NMxxxT.46 0.84 1. supply is met according to AS/NZS 3000:2000.84 1.38 9. 5 seconds for other circuits including submains and final sub circuits supplying fixed or stationary equipment (clause 1. then a larger cross-sectional area cable may be needed.75 5.5 2.31 0.11 3. Cross -sectional area of cable – The smaller the cross -sectional area of a cable.75 14.4 secs 30.5 1.25 Circuit length – Circuit impedance increases with the length of a circuit.72 0.92 0.22 7.c. FIGURE : 10 Example 1 Project 40m of cable length across on to the 240mm2 cable curve. or 12kA for a phase to neutral fault. *Prospective Short Circuit Current (PSCC).10 Subject to technical changes . Estimation of Prospective Fault Current Actually calculating prospective short-circuit current is not in itself difficult but it does require basic data which is not always available to the electrical installation designer.Prospective fault current Calculation of Prospective Short Circuit Current Several excellent proprietary computer programs are now available for calculating the prospective fault level at any point in the installation. which in fact would be the most likely type of fault. if it were a 3 phase symmetrical fault. The transformer is adjacent to the main switchboard so the prospective short-circuit current (PSCC*) on the main switchboard busbars is estimated as 30kA. Fig 11 shows a typical 3 phase 4 wire 400V system fed by a 1000 kVA transformer. This type of chart always gives a prospective fault level greater than that which would have been arrived at by calculation using accurate basic data. From this point project down onto the 28kA curve. From this point projecting across we note that the prospective fault level at the panelboard is 24kA. the length of conductor is doubled. The probable short-circuit current on the panelboard feeder circuit is estimated as 24kA. (Note: when estimating a phase to neutral prospective short-circuit current. They are also able to select the correct size and type of cable and match this with the correct circuit protective device. 2 Project 60m of cable length across onto the 70mm2 cable curve. this is nearly always at the extremity of the protected cable and more often than not a single phase or earth fault. The panelboard feeder circuit breaker (B) should have an Icu 30kA and an Ics 24kA. FIGURE : 12 The relationship between probable short-circuit current and service short-circuit breaking capacity is explained. Therefore it is safe to use but sometimes may result in an over engineered system. FIGURE : 11 F. The probable short circuit is the type of short circuit which is most likely to occur. It is therefore usual to use a simple chart as shown in Fig 10 to estimate the prospective short circuit current.) Therefore for this application the main switchboard incoming circuit breaker (A) should have an Ics 30kA and an Icu 30kA. From this point projecting across we see that the prospective fault level at the MCB distribution board is 10kA. From this point project down on to the 24kA curve. Load break switches description the HA series are a multi-pole load disconnector switch with manual operation.5 mm 2 characteristics module mm 36 cat.visualised breaking . ref HA302 3 pole isolator 690V~ In 40A 3 In 63A 54 HA303 3 pole isolator 400V~ 6 In 80A 108 HA304 6 In 100A 108 HA305 HA302 6 In 125A 108 HA306 8.double breaking per phase .complying with IEC60947-3 description width in I 17.DIN rail mounting .5 In 250A 142 HA309M 3 pole isolator 400V~ - In 250A - HA354 - In 400A - HA356 HA307 In 630A HA358 - In 800A - HA360 - In 1250A - HA362 - In 1600A - HA364 4 pole isolator 400V~ 6 In 125A 108 HA406 8.5 In 200A 142 HA308 .rotary handles complete with extension shaft .3 or 4 pole .5 In 200A 142 HA408 HA354 F.11 Main incomers 8.auxiliary contacts .padlockable handle . technical data . They enable making and breaking on load and safety isolation of any low voltage installation.5 In 160A 142 HA307 8. technical data .cable clamp/ line or load side HZ062 HZC002 1 HZ072 F.5 mm - characteristics box qty In 400A .rotary handles complete with extension shaft .250V~ suitable for HA354/HA356/ HA358/HA360/HA362/ HA364 terminal shrouds 1 to suit HA354/switch-line or load side HZ023 HZC203 1 to suit HA356/HA358/ switch-line or load side HZC205 1 to suit HA307/HA308 switch-line or load side (cable lug connection) to suit HA307/HA308/ switch c/.12 .DIN rail mounting .visualised breaking .3 or 4 pole .padlockable handle .complying with IEC60947-3 description width in I 17.AC23 In 630A . ref.double breaking per phase .AC23 cat.Load break switches description the HA series are a multi-pole load disconnector switch with manual operation. HA457 HA458 4 pole isolator 400V~ accessories rotary handles HA457 black IP65 to suit HA360/HA362/HA364 black IP55 to suit HA354/HA356/HA358 HZC003 HZC002 black IP55 to suit HA304/HA305/HA306/HA307/HA308 extension shafts 320mm to suit HA360/HA362/HA364 HZC001 HZC106 HZC106 320mm to suit HA354/HA356/HA358 HZC102 200mm to suit HA304/HA305/HA306/HA307/HA308 HZC103 auxiliary contacts In 5A .auxiliary contacts . They enable making and breaking on load and safety isolation of any low voltage installation.250V~ suitable for HA302/HA303 In 5A -250V~ suitable for HA304/HA305/ HA306/HA307/HA308 HZ021 HZ022 HZC003 In 16A . 5 2. according to IEC 60947-3 Application disconnector switches at installation head or for resistive circuits (lighting) switches in secondary circuits or reactive circuits (capacitor banks) switches feeding one or serveral motor or inductive circuits (series motors.5 10 12 12 12 16 16 16 30 2.5 2. magnetic brakes) Main incomers Utilisation category Use AC DC AC20 DC20 off-load making & breaking Subject to technical changes AC21 DC21 resistive loads including moderate overloads AC22 DC22 inductive & resistive mixed loads including moderate overloads AC23 DC23 loads made of motors or other hightly inductive F.13 loads .5 4 4 4 45 45 55 110 110 13 33 33 33 150 150 150 90/110 150/185 40 51 63 80 100 100 132/132 220/220 280/280 150/185 13 450/450 185/220 26 710/710 475/475 50 710/710 475/475 50 400 VAC 11 690 VAC 11 short time withstand current 1 sec (kA 1.A = frequent operation / B = infrequent operation (2) with terminal shrouds or phase barriers Application condition & utilisation category.cat ref 63 800 8 A/B 80/80 80/80 80/80 80/80 40/40 25/25 80/80 100/100 125/125 160/160 200/200 200/250 250/250 400/400 630/630 25/25 25/25 63/80 63/80 63/80 125/160 250/315 315/315 40/40 40/40 160/160 160/160 160/160 200/250 400/400 500/500 800/800 800/800 800/800 100/100 125/125 160/160 200/200 200/250 250/250 400/400 630/630 800/800 100/100 125/125 160/160 200/200 200/200 250/250 400/400 500/630 800/800 100/100 125/125 160/160 200/200 200/200 250/250 400/400 630/630 800/800 100/100 125/125 160/160 200/200 200/250 250/250 400/400 630/630 800/800 1250/1250 1250/1250 1250/1250 1250/1250 1000/1000 1000/1000 1250/1250 A/B A/B A/B A/B A/B A/B A/B A/B A/B A/B 8 8 8 8 8 8 12 12 12 12 12 A/B 1600/1600 1600/1600 1250/1250 1600/1600 1000/1000 1000/1000 1600/1600 800 800 800 800 800 800 1000 1000 1000 1000 1000 80 100 125 160 200 250 250 400 630 800 1250 1600 HA302 HA303 HA304 HA305 HA306 HA307 HA308 HA309M HA354 HA356 HA358 HA360 HA362 HA364 thermal current Ith 40 insulation voltage Ui (V) 8 800 800 impulse withstand voltage Uimp (kV) 8 rated operation current (A) A/B A/B 400VAC(1) AC-21A / AC-21B 40/40 63/63 AC-22A / AC-22B 40/40 63/63 AC-23A / AC-23B 32/32 63/63 690VAC(2) AC-20A / AC-20B 40/40 63/63 AC-22A / AC-22B 40/40 63/63 AC-23A / AC-23 20/20 50/50 220VDC DC-20A / DC-20B 40/40 63/63 operational power (kW) 18 18 9 1.characteristics (according to IEC 60947-3) rms) short circuit making capacity (kA peak) 6 connection 50 20 20 20 50 50 50 95 95 95 150 32 240 40 2X300 50 2X300 63 4X185 100 6X185 100 max cable section (mm) 16 max busbar width (mm) - (1) A/B = category with index .25 Load break switches . 14 F. DIN HRC fuse carriers. fuse carriers. RCBO’s. surge protection devices and emergency test lighting packages. installations and equipment. www.14 <#> . such as miniature circuit breakers. auxiliaries and accessories. earth leakage add-on blocks.hagerbr.Energy distribution Protection Hager offers a wide range of Protection Devices. earth leakage relays and torroids.com. RCCB‘s. DIN socket outlets.au F. providing practical solutions for protecting people. MCB’s G.15 G.13 G.80 .10 G.19 G.18 G.2 G.accessories Earth leakage relays and torroids SPD selection for residential.17 G.14 G.1 Protection . rural and commercial areas Surge protective devices Emergency lighting discharge test packages G.6 G.12 G.125A MCB’s .21 MCB’s .11 G.accessories Fuse carriers DIN HRC fuse carriers DIN socket outlets Earth leakage add-on blocks RCCB’s RCBO’s Safety switches .12 G.20 G. tripping characteristics: magnetic level is set at 5 .mechanical life : 20.4.complies with AS/NZS60898 .2 45 .curve) .current rating : 6 to 40 A .10 x In(C .MCB’s .5kA C .breaking capacity : 4500A .In domestic installations technical data .5mm 1 pack pty 12 cat ref.voltage rating : 230/400V .bi-connect allowing two connection points accessories .rigid conductor 25mm2 flexible conductor 16mm2 . NS106 single pole 10 1 12 NS110 13 1 12 NS113 16 1 12 NS116 NS120 20 1 12 NS120 25 1 12 NS125 32 1 12 NS132 40 1 12 NS140 double pole 10 2 6 NS210 16 2 6 NS216 20 2 6 NS220 25 2 6 NS225 32 2 6 NS232 40 2 6 NS240 G.LZ060.000 operations connection capacity .Curve description protection and control of circuits against overloads and short-circuits: . MZN175 68 44 description current rating (A) 6 width in I 17. current rating : 2 to 63 A .MCB’s .Curve description protection and control of circuits against overloads and short-circuits: .voltage rating : 230/400Vac .MZ203.6kA C .16mm2 flexible accessories .MZ202.curve) .In commercial installations Technical data .LZ060. NT102C NT104C NT106C NT110C NT116C NT120C NT125C NT132C NT140C NT150C NT163C NT206C NT210C NT216C NT220C NT225C NT232C NT240C NT250C NT263C NT302C NT304C NT306C NT310C NT316C NT320C NT325C NT332C NT340C NT350C NT363C Protection G.mechanical life : 20.10 x In(C . MZ206 68 44 description current rating (A) 2 4 6 10 16 20 25 width in I 17.bi-connect allowing two connection points connection capacity . MZN175.complies with AS/NZS 60898 .000 operations .tripping characteristics: magnetic level is set at 5 .5mm 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 pack qty 12 12 12 12 12 12 12 12 12 12 12 6 6 6 6 6 6 6 6 6 4 4 4 4 4 4 4 4 4 4 4 cat ref.breaking capacity : 6000 A . MZ201.3 single pole NT110C 32 40 50 63 double pole 6 10 16 20 25 32 40 NT216C 50 63 triple pole 2 4 6 10 16 20 25 32 40 NT304C 50 63 45 .25mm2 rigid . MZ206.10kA D .Curve description protection and control of circuits against overloads and short-circuits: .MZ202.MCB’s . MZN121 68 44 description current rating (A) 6 10 16 20 25 32 40 50 63 width in I 17.16mm2 flexible accessories .MZN120.tripping characteristics: magnetic level is set at10 .5mm 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 pack qty 12 12 12 12 12 12 12 12 12 6 6 6 6 6 6 6 6 6 4 4 4 4 4 4 4 4 4 3 3 3 3 3 3 3 3 3 cat ref.current rating : 6 to 63 A .000A .25mm2 rigid .MZ203.000 operations connection capacity .voltage rating : 230/400V . NDN106A NDN110A NDN116A NDN120A NDN125A NDN132A NDN140A NDN150A NDN163A NDN206A NDN210A NDN216A NDN220A NDN225A NDN232A NDN240A NDN250A NDN263A NDN306A NDN310A NDN316A NDN320A NDN325A NDN332A NDN340A NDN350A NDN363A NDN406A NDN410A NDN416A NDN420A NDN425A NDN432A NDN440A NDN450A NDN463A single Pole NDN220A double pole 6 10 16 20 25 32 40 50 63 triple pole 6 10 16 20 25 32 40 50 63 four pole 6 10 16 20 25 32 40 50 63 G.In commercial and light industrial installations technical data .20 x In .4 45 .LZ060. MZN175.complies with AS/NZS 60898 . MZ201.mechanical life : 20.breaking capacity : 10. MCB’s - 10kA C - Curve description protection and control of circuits against overloads and short-circuits: - In commercial and light industrial installations technical data - complies with AS/NZS 60898 - tripping characteristics: magnetic level is set at 5 - 10 x In - breaking capacity : 10,000A - voltage rating : 230/400Vac - current rating : 1 to 63 A - mechanical life : 20,000 operations connection capacity - 25mm2 rigid - 16mm2 flexible accessories - LZ060, MZN175, MZ201, MZ202,MZ203, MZ206, MZN120, MZN121 68 44 description current rating (A) 1 2 3 4 6 10 16 20 25 width in I 17.5mm 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 pack qty 12 12 12 12 12 12 12 12 12 12 12 12 12 6 6 6 6 6 6 6 6 6 6 6 6 6 4 4 4 4 4 4 4 4 4 4 4 4 4 cat ref. NCN101A NCN102A NCN103A NCN104A NCN106A NCN110A NCN116A NCN120A NCN125A NCN132A NCN140A NCN150A NCN163A NCN201A NCN202A NCN203A NCN204A NCN206A NCN210A NCN216A NCN220A NCN225A NCN232A NCN240A NCN250A NCN263A NCN301A NCN302A NCN303A NCN304A NCN306A NCN310A NCN316A NCN320A NCN325A NCN332A NCN340A NCN350A NCN363A Protection G.5 single pole NCN110A 32 40 50 63 double pole 1 2 3 4 6 10 16 20 25 NCN220A 32 40 50 63 triple pole 1 2 3 4 6 10 16 20 25 32 NCN332A 40 50 63 45 Miniature circuit breakers 80 - 125A Thermal magnetic circuit breakers Curves - ‘C’ - ‘D’ In 80 to 125A These circuit breakers are intended for the protection of circuits against overloads and short circuits in residential, commercial and industrial premises. The circuit breakers, curve ‘C’, are adapted to the protection of the circuits in residential and Commercial premises. The circuit breakers, curve ‘D’, are particularly adapted to the protection of the circuits where the installations are subject to high in-rush currents. HMC curve ‘C’ 15000 15kA of 80 - 100 - 125A : width 1.5 / pole HMD curve ‘D’ 15000 15kA of 80 - 100 - 125 A : width 1.5 / pole HMF curve ‘C’ 10000 10kA of 80 - 100 - 125 A : width 1.5 / pole Series HMC, HMD, HMF at a glance; Reinforcement of terminal harness: The reduction in distortion ensures maximum torque can be applied directly to conductor. 3.5Nm Accessories, Interphase barriers and terminal cover. Front product labelling. MCB’s are equipped with a pull down window that allows identification of protective device. Tightening compensation system; The unique design of the terminal compensates and corrects any cable distortion. The ‘OFF’ position is clearly shown by a green indicator on the handle. Fast on connection; The MCB’s are equipped with top & bottom ‘fast-on’ terminals. They are used to supply low powered auxiliaries such as meters, indicating lights etc... Trip free mechanism: MCB’s have quick and simultaneous closing of contacts, regardless of operating cycle, hence, the working life is increased. Options ; Auxiliaries; standard 63A MCB auxiliaries (shunt, trip etc...) can be facilitated. Lockable handle ; MCB’s can be locked in the <OFF> position by the integrated locking facility within the handle. The lock allows either sealing wire or a cable tie that may have a warning card attached ensuring safe working environment. Model Icc/Curve Accessories Fast-on connection Tightening comp. system YES YES Lockable handle YES YES Front product labelling YES YES HMF HMD, HMC 10kA, C 15kA, C, D YES YES YES YES G.6 Subject to technical changes MCB’s - 80 - 125A HMF : ‘C’ 10000 - 10kA Curve ‘C’ 10000 (IEC 60898-1) 10kA IEC 60947-2 In 80 to 125A Tripping curves : ‘C’ magnetic setting between 5 and 10In. Use : residential, commercial and industrial premises Connection capacity : - 35mm flexible wire - 70mm rigid wire KEMA In conformity with the IEC 60898-1, 947-2 approved description In / A width in I 17.5mm 1.5 cat ref. HMF180T Circuit breakers 1 pole 80 100 1.5 HMF190T 125 1.5 HMF199T HMF199T Circuit breaker 2 pole 80 3 HMF280T 100 3 HMF290T HMF299T Circuit breakers 3 poles 80 4.5 HMF380T 100 4.5 HMF390T 125 4.5 HMF399T HMF399T G.7 Protection 125 3 HMF299T 5mm 1.80 . HMC180T Circuit breakers 1 pole 80 100 1.15kA Curve ‘C’ 15000 (IEC 60898-1) 15kA IEC 60947-2 In 80 to 125A Tripping curves : ‘C’ magnetic setting between 5 and 10In.5 HMC190T HMC199T 125 1. commercial and industrial premises Connection capacity : .35mm flexible wire .5 HMC199T Circuit breaker 2 pole 80 3 HMC280T 100 3 HMC290T 125 3 HMC299T HMC299T Circuit breakers 3 poles 80 4. Certification approved to AS/NZS 60898 description In / A width in I 17.8 . Use : residential.5 HMC380T 100 4.5 HMC399T HMC399T Circuit breakers 4 poles 80 6 HMC480T N 100 6 HMC490T 125 6 HMC499T HMC499T G.5 HMC390T 125 4.125A HMC : ‘C’ 15000 .5 cat ref.MCB’s .70mm rigid wire KEMA In conformity with the IEC 60898-1947-2. 125A HMD : ‘D’ 15000 .5 HMD399T Circuit breakers 4 poles N 80 4.MCB’s .5 HMD190T 125 1. Use : commercial and industrial premises Connection capacity : .80 . HMC HMD description characteristics cat ref.5 HMD380T HMD399T 100 4. MZN130 Terminal covers terminal cover.5 HMD490T Protection G.5 HMD499T Accessories for circuit breakers HMF.15kA Curve ‘D’ 15000 (IEC 60898-1) 15kA IEC 60947-2 In 80 to 125A Tripping curves : ‘D’ magnetic setting between 10 and 20In.5mm 1.35mm flexible wire .9 HMD499T 125 4.5 HMD199T HMD199T Circuit breaker 2 pole 80 3 HMD280T 100 3 HMD290T 125 3 HMD299T Circuit breakers 3 poles 80 4. sealable MZN130 Phase barrier 1 set of 3 phase barriers MZN131 MZN131 .70mm rigid wire KEMA In conformity with the IEC 60898-1947-2.5 HMD480T 100 4. HMD180T Circuit breakers 1 pole 80 100 1.5 cat ref. Certification approved to AS/NZS 60898 description In / A width in I 17.5 HMD390T 125 4. Accessories description all auxiliaries are common to both single and multi-pole circuit breakers and safety switches (RCCBs and RCBOs). (Auxiliary contact. These auxiliaries are fitted to the left hand side of devices. MZ201 auxiliary contact 5A . The coil is protected by a contact which cuts the supply after MCB trips if supply falls to 35 to 70% of nominal voltage the MCB will trip 14 22 auxiliary contact with reset 91 93 0.10 .230V~ 13 21 NO + 1NC allows remote indication of main contact status auxiliary contact as above.5 cat ref.5 MZ202 92 94 MZ202 shunt trip relay C1 C2 1 MZ203 undervoltage A1 U< 1 MZ206 MZ203 MZ203 or MZ201 MZ202 MZ201 or MCB MZ206 locking device to lock the MCB handle in on/off position avoids overheating for DIN rail modules when several devices mounted side by side are carrying high continuous loads 2 MZN175 heat dissipation inserts 0. Reset switch triggers on overload or short circuit allows for remote tripping of MCB.5kA MCBs) description characteristics width in I 17.5 LZ060 MZN175 terminal cover & screw shield phase barriers (1 set of 3) MZN120 MZN121 G.5mm 0.MCB’s . shunt trip and undervoltage relays are not suitable for use with 4. rated voltage: 415V ac 250V dc .7mm 6A L17300 8A L17400 10A L17500 LS201 16A L17600 20A L17700 25A L17800 Protection G. 4 way 1 L14700 LH901 LH904 LH901/W KM06A . (supplied without fuse cartridge) Locking kit MZN178 BS88 cartridge fuse 29 x 12.Fuse carriers description protection and control of circuits against overloads and short circuits: .5mm 1 cat. ref LS201 fuse carriers for BS88 fuses.fuse cartridge not supplied connection capacity .16mm2 flexible + busbar description current rating (A) 32A max width in I 17.16mm2 rigid cable .11 32A L17900 handle link pin 2 L022 handle link pin 3 L023 spare fuse holder (DIN mounted) service fuse back-wired 100A for 22mm service fuse back-wired 100A anti-intrusion fuse carrier (wedge) to suit LH901 100A neutral link.fusing factor : class Q1 . 80kA at 415 Vac 40kA at 250 Vdc .suitable for fuses which comply with BS88: Part I:1998 technical data .rated breaking capacity. 5 SNO10DA 2.DIN HRC Fuse carriers description size according to DIN from 00 to 2 to suit fuses according to AS/NZS60269 technical data DIN fuses typically have breaking capacity to 100kA at 500V (supplied without fuse cartridge) . ref DIN mounted socket outlets DIN mounted 10A double pole auto switched complete with safety shutters and ‘on’ indicator DIN mounted 15A double with safety shutters and ‘on’ indicator 2.240mm2) LZ152 DIN Socket Outlets description width in I 17.5 SNO15DA SNO15DA G.70mm2) LZ051 suitable for LT150 (70 . ref fuse switch disconnectors 3 x size 00 160A DIN blade fuses LT052 3 x size 1 250A LT150 DIN blade fuses 3 x size 2 400A DIN blade fuses LT250 cable clamps LT150 suitable for LT052 (6 .connection capacity 70 .150mm2) LZ151 suitable for LT250 (120 .12 .5mm cat.240mm description characteristics cat. Satisfies mechanical protection clauses of AS3000:2007 all devices have a test facility all devices are type A nuisance tripping protection protected against transient voltages technical data . 3 or 4 pole MCBs .1 connection capacity flexible: 25A = 6mm2 40A = 16mm2 63A = 16mm2 rigid: 25A = 10mm2 40A = 25mm2 63A = 25mm2 - description residual current IIr n 30mA 30mA 30mA 100mA 100mA 300mA 300mA current rating (A) width in I 17.complies with AS/NZS61009. ref BD225T BD240T BD263T BE225T BE263T BF225T BF240T BF263T BD325T BD340T BD363T BE363T BF363T BD425T BD440T BD463T BE425T BE463T BF425T BF440T BF463T Protection G.the combination device then provides protection against overload. short circuits and earth leakage faults.these devices are designed to be fitted to the right hand side of 2.5mm cat.13 2 pole RCCB add-on blocks 25A 40A 63A 25A 63A 25A 40A 63A 25A 40A 63A 63A 63A 25A 40A 63A 25A 63A 25A 40A 63A 2 2 2 2 2 2 2 2 2 3 3 3 3 2 3 3 2 3 2 3 3 BD325T 3 pole RCCB add on blocks 300mA 30mA 30mA 30mA 100mA 300mA 4 pole RCCB add-on blocks 30mA 30mA 30mA 100mA 100mA 300mA 300mA 300mA .Earth leakage add-on blocks description for use with NCN + NDN + NT MCB’s . 14 .RCCB’s description the safety switch is designed to open a circuit automatically in the case of a fault between phase and earth and or neutral and earth.400V shunt trip .trip free mechanisms accessories . 2 modules.1 .auxiliary & alarm contacts .Approved to AS/NZS61008.positive contact indication windows .25mm . 80A. 100A) 2 2 . 63A. 2 modules.30mA. 2 and 4 modules.Safety switches . 80A. 100A.Rigid (50mm2 for 80A.Flexible (35mm2 for 80A. 100A . 4 modules -80A.100A) .5mm cat. greater than or equal to rated tripping current. 25A 40A. 25A. commercial or industrial installations technical data . use in domestic. ref CD225T CD240T CD263T CD280T CD284T CE225T CE240T CE263T CE280T CE284T CD425T CD440T CD463T CD480T CD484T CE480T CE484T CC216T CD227T CD242T CD265T CE281T CE285T CD427T CD442T CD465T CD481T CD485T CE481T CE485T double pole type AC 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 80A 100A 16A 25A 40A 63A 80A 100A 25A 40A 63A 80A 100A 80A 100A 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 2 2 2 2 2 2 4 4 4 4 4 4 4 CD240T four pole type AC 100mA 100mA 30mA 30mA 30mA 30mA 30mA 100mA 100mA double pole type A AC and pulsating DC residual currents 10mA 30mA 30mA 30mA 100mA 100mA four pole type A pulsating DC and AC residual currents 30mA 30mA 30mA 30mA 30mA 100mA 100mA CD440T G. 16A .230V undervoltage release description residual current Ir n 30mA 30mA 30mA 30mA 30mA 100mA 100mA 100mA current rating (A) width in I 17.10mA.16mm .voltage rating. 230/400V~ connection capacity . 40A.toggle locking device .100mA.neutral links . 100A .earth fault indication window .63A. 2 modules description Compact combination devices which provide MCB overcurrent protection & earth leakage protection. features . Type A device is designed with intrinsic features that can detect a.c. All units are two pole with line neutral switched & are 2 modules wide. ref AD806T AD810T AD813T AD816T AD820T AD825T AD832T AD811T AD817T AD821T AD833T AD906T AD910T AD913T Protection G.toggle locking device . component. The units are available with various current rating ranging from 6A-40A.c.5mm cat. Type A devices are able to tolerate this d.RCBO’s . component.5 kA Type AC Ph N 6A 10A 13A 16A 20A 25A 32A 10A 16A 20A 32A 6A 10A 13A 16A 20A 25A 32A 40A 10A 16A 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 30mA 30mA 30mA 30mA AD820T 2 module RCBO 6kA Type AC Ph N 30mA 30mA 30mA 30mA 30mA 30mA 30mA AD917T 2 module RCBO 6kA Type A Ph N 30mA 10mA 10mA 2 module RCBO 6kA Type A Ph N 30mA 30mA 30mA 30mA 30mA 30mA 6A 10A 13A 16A 20A 25A 32A 40A 2 2 2 2 2 2 2 2 AD907T AD911T AD914T AD917T AD921T AD926T AD933T AD941T AD120T 30mA 30mA 45 . The range includes Type A & Type AC devices. Standard type AC devices may become saturated by the d.earth fault indication window .c. sinusoidal residual current. Solid state devices that are connected to permanent wiring have an increased possibility of generating residual current containing a d.25mm2 rigid accessories . as well as pulsating d. component & may not detect a description residual current Irn 30mA 30mA 30mA 30mA 30mA 30mA 30mA 2 module RCBO 4.5kA Type A Ph N residual current. residual currents.c.16mm2 flexible .shunt trip .c.auxiliary & alarm contact .c.trip free mechanisms connection capacity .undervoltage release 68 44 current rating (A) width in I 17.15 AD916T AD920T AD925T AD932T AD940T AC911T AC917T 2 module RCBO 4. Type AC devices are the standard unit & will detect an a. Typically they will operate within 40ms and occasionally much faster.16 . then another residual current relay can be installed upstream and the settings of the upstream device ( time and residual current) adjusted higher again. It is advisable to set the residual current relay at a residual higher tripping current than a downstream devices (> 30mA) since the upstream device will see the accumulation of leakage currents from the entire installation. They can be used as an upstream device to achieve residual current protection of the entire installation. switch mode power supplies are particularly prone to leak currents to earth). G. It can only be achieved by delaying the tripping of the upstream residual current devices. Hager residual current relays (HR210. The residual current setting will depend on the quantity and type of equipment connected to the installation (Immersion water heaters. The time delay should be set above zero to 300ms. The down stream device would typically be a 30mA or occasionally a 10mA residual current device. If further levels of protection are required upstream from the hager residual current relay. but the limit of discrimination is far too low for practical purposes.5mm cat. HR212) have adjustable time delay and residual current settings. ref AD110T 1 module RCBO 6kA Type AC load N N L out out FE 10A 1 1 1 1 1 1 1 1 1 1 1 1 1 1 30mA 16A AD116T 30mA 20A AD120T 30mA 25A AD125T 30mA 32A AD132T ADA120T FUTURE RELEASE 1 module RCBO 6kA Type A load N N L out out FE 30mA 10A ADA110T 30mA 16A ADA116T 30mA 20A ADA120T 30mA 25A ADA125T 30mA 32A ADA132T FUTURE RELEASE 1 module RCBO 6kA Type A load N N L out out FE 10mA 10A ACA110T 10mA 16A ACA116T 10mA 20A ACA120T 10mA 25A ACA125T Technical information for RCCB’s & RCBO’s Discrimination between Residual Current Devices In theory it is possible to achieve current discrimination between residual current devices. Time delay is the only reliable and by far the best method used to obtain discrimination.RCBO’s .1 module description residual current Irn 30mA current rating (A) width in I 17. .accessories function description width in I 17.17 Protection AC shunt trip 230-415V AC 110-130V DC allows remote tripping of device 1 MZ203 . MZ 203. with hasps of 4. ref CZ001 combination auxiliary & alarm switch 2xNO + 2xNC 6A-230V~ 3A-440V~ CA allows remote indication of main contact status SD indicates a fault condition (eg Safety Switch tripped) CZ001 If shunt trip or undervoltage release is required. + MZ206 CZ001 (CA + SD) Safety Switch auxiliary switch 1xNO + 1xNC 6A-230V~ 3A-440V~ allows remote indication of main contact status 0. the CZ001 must be used as a coupler. toggle in the on/off position.5 MZ202 AC undervoltage .75mm diameter max MZN175 G.5mm 1 cat.Safety switches .5 MZ201 alarm switch 1xNO + 1xNC 6A-230V~ 3A-440V~ indication of a fault condition 0.. fitted with an auxiliary switch 1 MZ206 Looking Kit supplied without padlock allows locking of the device. will accept two padlocks .when voltage falls by 35% of Un. 1/0.1/0.1/0. designed on an electronic basis. .class A .5 to 4mm supply contactor trip earth leakage relay detection torroid conforms to IEC 1008 description width in I 17. The relays are linked with detection torroids.5/1/3/10A adjustable time delay Ut= 0/0. which ensure the monitoring of earth fault currents.3/0.5/1/3sec HR410 HR410 earth leakage relay premium 3 c/o contact 250V 6A ~ AC1 fail safe contact 250V 6A ~ AC1 pre-alarm contact 250V 6A ~ AC1 adjustable sensitivity IUn= 0.75/1sec of torroid: 35mm HR441 circular section torroids of torroid: 35mm HR801 of torroid: 70mm HR802 of torroid: 105mm HR803 HR804 of torroid: 140mm HR804 G.5mm 3 characteristics cat.5/0. When the fault current rises above the selected level.protected against nuisance tripping .5/1/3sec bargraph = 5% .3/0.1.4/0.75% IUn HR420 HR420 earth leakage relay integral torroid 6 HR441 c/o contact 250V 6A ~ AC1 adjustable s sensitivity IUn= 0.35mm . common characteristics .supply voltage 230V +/.18 .flexible .1/0.Earth leakage relays & torroids description These units ensure the protection of electrical installations and the protection of persons against direct and indirect contact.1 to 2.70mm .extra output contact (250V-AC1/6A) to enable remote indication of fault currents above 50% of Irn .105mm . .1/0.03/0.4/0.20% 50 / 60Hz .visual display of fault .3/0.output: 1 c/o contact 250V~ 6A AC1 .rigid .140mm connection capacity .remote test and reset by three wire link torroid circular diameter.3/0.display of fault current prior to triggering relay (5%-75%) . ref earth leakage relay standard c/o contact 250V 6A ~ AC1 adjustable sensitivity IUn= 0.adjustable sensitivity & time delay (sealable) .positive / local reset required after a fault is detected.5/1/3A adjustable time delay Ut= 0/0.03/0.3/0. the outputs of the relay operate & depending on the relay selected. . it can have both adjustable sensitivity and time delay that can provide selectivity/ discrimination.03/0. This range of products contains a set of earth leakage relays.3/0.5mm .positive safety: the relay trips in the event of a break in the connection between relay and torroid.5/1/3/10A adjustable time delay Ut= 0/0.1/0. By installing this device the residual voltage (Up) remaining in the system will be less than 800V. tall trees or near a hill top in a lightning prone area? 3 If the answer is YES to any of the above. This will provide protection against direct lightning strikes. the cartridge should be replaced as soon as possible. This map is compiled by the Bureau of Meteorology.5kA. computers. the country is split into three zones of activity. the installation is protected from indirect transients up to 40kA. The next step is the selection of the Transient Protective device.19 . Subject to technical changes G. rural and commercial areas Direct lightning protection The criteria for installing a lightning protective product.g: 3 x SPN165R All Hager Class II medium protection products have plug-in cartridges available in two versions: SPD’s with a base element and cartridge with a status indicator (to show the end of the life of the device). the installation is protected from indirect transients up to 15kA. If the installation is 3 phase then install a SPN408S. This will minimise the chance of damage to microchips within these devices. This is indicated with the suffix D at the end of the item number. Equipment Protection To ensure that today’s and importantly tomorrow’s. then a spark gap device is not required. If the answer is NO. Refer to the user instructions for a wiring diagram. the yellow zone is high exposure and the grey zone is moderate exposure to lightning activity.SPD selection for residential. the installation is protected from indirect transients up to 65kA. Indirect Transient Protection To ensure protection of the installation it is vital to have adequate protection from the harmful effect of transients. Protection 2 3 1 If the answer is YES. and a cartridge with a reserve status indicator. SPD’s with a base element which contains an auxiliary contact for remote signalling (audible and visual). sensitive and valuable electronic devices continue to provide entertainment and service. SPA212A & SPA412A (single & three phase respectively) have dual earth and phase / neutral terminals. Tip: For three phase installations. TV’s. This will minimise the residual current. Install SPN140D/R. While the installation is still protected.. Hi-Fi system. SPN165 only available as R - If the answer is NO to the above. fax machines. Install SPN115D/R. Tip: If maximum demand of the installation is 125A or less then use both terminal screws per pole for through connection. it is vital to bring the residual voltage below 800V. The orange zone is maximum exposure. If the maximum demand is greater than 125A then tap off each phase for parallel connection.. The reserve status function has an added intermediate step which indicates that the cartridge needs to be replaced. This connection method reduces any additional voltage drop in the connecting cables to virtually zero thereby obtaining the best possible Up to the installation. please refer to the Hager ‘pocket size SPD selection guide’. 3 Hager Thunder Day Map This regional map illustrates the lightning activity across Australia and is based upon the ‘Thunder Day Map’ that appears in AS/NZS 1768 (Int): 2003. DVD players. Does the installation contain a lightning rod? 2 1 In what region is the installation located? Install SPN165R. Is the installation adjacent to tall structures. you will require three of the selected SPDs E. Answering the question below will allow you to ascertain which Hager device best suits the needs of the installation. Further installation protection is provided by the fact that the devices are connected in both common and differential modes (L-E/N-E/L-N) together within inbuilt auto protection up to 12. This product is indicated with the suffix R at the end of the item number. install SPN208S. microwave ovens.VCR’s. 1 The next system consideration is the protection of the installation’s sensitive and valuable electronic equipment. it is recommended to install the SPA212A (3 phase = SPA412A) spark gap device. For quick selection of the best SPD product while in the field. Does the installation contain electronic appliances? Eg. Both references. the installation requires no further protection. As indicated. The process of selecting the correct SPD for protection against transients is a simple one. etc. washing machines.2 1.2 275 <1.5mm cat ref. For detailed information. SPN408S Class II Fine Protection to be used in cascade with medium protection devices Refer to cascade table for Up values Designation 2 4 8 8 2 2 1. Surge protective devices are strongly recommended in sites that are exposed to lightning.5 In kA - Up kV Uc V width in I 17. These transients can cause anything from the premature aging of equipment.0 275 <1. SPN505 SPN505 Protection for those devices analog 10 connected to the telephone network. Protection is assured in both common & differential modes. to the complete destruction of electrical components and the entire electrical distribution system. ref SPA212A SPA212A Class I Spark gap arrester for areas where risk of lightning is prevalent.Surge protective devices description hager SPD’s protect electric and electronic equipment against transients. VCR’s. PC’s.20 .5mm cat ref. SPA412A 1 1 1 1 1 65 40 40 15 15 20 15 15 5 5 <1. logic failures and down time. to protect sensitive and expensive electrical equipment such as TV’s. alarms etc. SPN040D Class II replacement cartridge for SPN1XXX 1 1 1 1 1 Yes Yes Yes - Yes Yes 1 1 1 1 1 SPN065R SPN040R SPN040D SPN015R SPN015D designation line In kA characteristics width in I 17.5 255 8 SPA412A description Class II Medium Protection Metal Oxide Varistors (MOV’s) high diverting capacity poles Iimp In kA Up kV Uc V width in I 17.2 275 <1.5mm 1. please consult the hager Surge Protective Devices technical handbook description poles Iimp kA 12..0 275 1 1 1 1 1 SPN165R SPN140R SPN140D SPN115R SPN115D SPN208S replaceable cartridge reserve option indication and changeover contact on ‘R’ catalogue reference description poles Iimp In kA Up kV Uc V width in I 17. Test wave 10/350us 2 <2. width in I 17. Hi-Fi’s.c Uc: 170vd.5 cat ref. standard status ind. originating from lightning and switching transient sources .c G.5mm 4 cat.5 255 4 12.5 275 <1.5mm cat ref. Un: 130vd.5 - <2.25 255 255 2 3 SPN208S SPN408S Poles reserve status ind. control gear & internal wiring EMERG1W These breakers are not supplied as part of the standard test package. initiating operation of the emergency lights.push button 1N/O (green) + 1N/C (red) .1 and 2. In accordance with AS2293.1(b) the test facility is capable of being manually reset. initiating the operation of the emergency lights.2. de-energising the coil of EM1 and returning the contacts to the normally closed position.4 Pole 40A N/C Contactor . In accordance with AS2293.2 of AS2293. the timer starts it’s operation and energises the contactor coil.IP 40 .3. together with a lockable door . 1 NC (red. 6A 240V 1 NO (green. Pushbutton B) EZNOO4: Delay Timer (EET) Set at 2 hours for initial commissioning (90mins there after) Clauses 2.2 1995 ‘Emergency Evacuation Lighting for Buildings’ a discharge test circuit MUST be installed in both existing and new installation for the purpose of testing the charge.2. application Hager’s EMERG1W offers a convenient and versatile discharge test facility for maintenance of emergency lighting systems. The four normally closed contacts of EM1 then open. de-energising the contactor coil returning the contacts to the normally closed position.1(b) the test facility is capable of being manually reset. 90mins thereafter. After 2 hours Timer EET completes its operation. Standard Emergency Test Components: 7 CIRCUIT 4 EM1-4 8 SVN391: Momentary Pushbutton. 240V AC coil 2.6 pole surface mount enclosure. This wired ‘off-the-shelf’ package offers the contractor a time saving solution and answers the needs of the industry in regard to the testing and maintenance of emergency lighting systems.1-2005 ES480: 4 pole normally closed contactor (EM1) 4P 40A AC1. EMERG1W GENERAL LIGHTING FROM 6A MCB CONTROL N CIRCUIT 1 EM1-1 1 2 EMERGENCY LIGHTING PUSH BUTTON SVN391 Red 1 2 GENERAL LIGHTING CIRCUIT 2 3 A1 4 B1 EET A2 EZN004 TIMER EM1-2 4 Green 3 GENERAL LIGHTING CIRCUIT 3 5 EM1-3 6 EET 15 18 A1 EMERGENCY LIGHTING EM1 A2 ES480 CONTACTOR GENERAL LIGHTING 1. ref emergency lighting discharge test package .Emergency lighting discharge test package -1 description The Hager Emergency Lighting Discharge Test Package has been developed to meet the needs of the electrical industry.3. completes its operation. Basic Operating Procedure: EMERGENCY LIGHTING Upon engaging Pushbutton A for 1 second the Delay Timer (EET) starts its operation and energises the coil of Contactor EM1. It can also be included in the hager range of Jyka panelboards by taking advantage of the DIN rail area at the top of the switchboard The EMERG1W test package includes . Timer EET resets and is ready for Green Pushbutton to start the timing cycle again. If the Red Pushbutton is pressed for 1 second. The timer. This package may be mounted separately using the supplied enclosure in situations where space in the switchboard is limited.21 Protection EMERGENCY LIGHTING .delay timer 0.12005 and AS/NZS2293.wired enclosure c/. Pushbutton A). description characteristics cat.1-2005 4. In accordance to AS2293.1 second to 10 hours use and implementation The EMERG1W works on the following principle: Upon engaging the Green push button for 1 second.12005 4. G. The four normally closed contacts open. If the red push button is pressed the timer resets and is ready for the green push button to start the timing cycle again. to be set at 2 hours (2hrs for initial commissioning. delay timer 0.4 pole surface mount enclosure.12005 and AS/NZS2293. This package may be mounted separately using the supplied enclosure in situations where space in the switchboard is limited. In accordance to AS2293. the timer starts it’s operation and energises the contactor coil. It can also be included in the hager range of Jyka panelboards by taking advantage of the DIN rail area at the top of the switchboard The EMERG2W test package includes . Pushbutton B) EZNOO4: Delay Timer (EET) Set at 2 hours for initial commissioning (90mins there after) Clauses 2.1(b) the test facility is capable of being manually reset.2. Basic Operating Procedure: Upon engaging the Green Pushbutton for 1 second the Delay Timer (EET) starts its operation and energises the coil of Contactor EM1. PUSH BUTTON SVN391 Red 1 2 GENERAL LIGHTING CIRCUIT 1 EM1-1 1 2 EMERGENCY LIGHTING Green 3 4 A1 B1 EET A2 GENERAL LIGHTING EZN004 TIMER CIRCUIT 2 3 EM1-2 4 EMERGENCY LIGHTING EET 15 18 A1 EM1 A2 ES230 CONTACTOR 1. The timer.3.IP 40 .1-2005 ES230: 2 pole normally closed contactor (EM1) 2P 25A AC2. Timer EET resets and is ready for Green Pushbutton to start the timing cycle again.1 second to 10 hours use and implementation The EMERG2W works on the following principle: Upon engaging the Green push button for 1 second.control gear & internal wiring EMERG2W FROM 6A MCB CONTROL N These breakers are not supplied as part of the standard test package. de-energising the coil of EM1 and returning the contacts to the normally closed position. Pushbutton A). Standard Emergency Test Components: SVN391: Momentary Pushbutton.wired enclosure c/. If the red push button is pressed the timer resets and is ready for the green push button to start the timing cycle again.2.push button 1N/O (green) + 1N/C (red) description . emergency lighting discharge test package .2 1995 ‘Emergency Evacuation Lighting for Buildings’ a discharge test circuit MUST be installed in both existing and new installation for the purpose of testing the charge. 2.1 and 2. After 2 hours Timer EET completes its operation. In accordance with AS2293. G. characteristics cat. initiating operation of the emergency lights.22 .2 description The Hager Emergency Lighting Discharge Test Package has been developed to meet the needs of the electrical industry. 90mins there after) completes its operation. The two normally closed contacts of EM1 then open.1(b) the test facility is capable of being manually reset. This wired ‘off-the-shelf’ package offers the contractor a time saving solution and answers the needs of the industry in regard to the testing and maintenance of emergency lighting systems.1-2005 4. If the Red Pushbutton is pressed for 1 second. de-energising the contactor coil returning the contacts to the normally closed position.12005 4. together with a lockable door . 240V AC coil. The two normally closed contacts the open. to be set at 2 hours (2hrs for initial commissioning. ref In accordance with AS2293. application Hager’s EMERG2W offers a convenient and versatile discharge test facility for maintenance of emergency lighting systems. initiating the operation of the emergency lights. 1 NC (red.2 of AS2293. 6A 240V 1 NO (green.Emergency lighting discharge test package .3.2 Pole 25A N/C Contactor . .23 .. What is the total value of all your electrical appliances. entertainment and IT equipment? Be prepared Hager’s three step (cascade) system approach will ensure you have the best level of protection for all your valuables. for you and your family.. G..au G. A small investment.) Energy Distribution Enclosure systems Wiring Accessories + Building Automation Cable management Surge Protection Ask yourself.hagerbr.there are times when you’re glad you were prepared.com. Energy distribution Protection (sec. A proven solution from Europe’s leading manufacturer. www. indicator lights. bells and buzzers that are used for isolation. transformers. voltmeters. ammeters. push buttons. G.Energy distribution Control & indication This section provides a range of switches.24 . installation monitoring and circuitry control. ammeters Current transformers (CT’s) Digital voltmeters.18 H.8 H.9 H.Isolating switches H.1 Changeover switches Selector switches voltmeters and ammeters Indicator lights Push buttons Analogue voltmeters.5 H.16 H.13 H. bells and buzzers Dimmers .9 H.17 H.2 H.7 H.12 H. ammeters Digital multimeter Kilowatt hour meters and hours counter Transformers.range overview Dimmers Dimmer system .10 H.11 H.1/10V pilots Motion detectors .20 Control & indication H.6 H.IP55 Motion detectors Presence detectors .3 H.4 H. technical data connection capacity: . 80A (1.2 45 . domestic installations require no more than one main switch for each metered supply.3.AC 22B duty specification (mixed resistive and inductive loads. As defined in AS/NZS3000-2007. 63. 4 poles) . 3 pole) .AC 22B duty specification (mixed resistive and inductive loads.2.3.In : 40. ref SB140T single pole 1 x 40A 250V~ 1 x 63A 250V~ 1 SB163T 1 x 80A 250V~ 1 SB180T SB163T 1 x 100A 250V~ 1 SB199T double pole 2 x 40A 250V~ 1 SB240T 2 x 63A 250V~ 1 SB263T 2 x 80A 250V~ 1 SB280T 2 x 100A 250V~ 1 SB299T triple pole 3 x 40A 400V~ 3 SB340T SB499T 3 x 63A 400V~ 3 SB363T 3 x 80A 400V~ 3 SB380T 3 x 100A 400V~ 3 SB399T four pole neutral right 4 x 63A 400V~ 4 SB463T N 4 x 100A 400V~ 4 SB499T H.Isolating switches description for use as a switch isolator in all types of circuits. Not motors) -50mm2 rigid cables -35mm2 flexible cables 68 44 description characteristics width in I 17. 2.5mm 1 cat. Not motors) 25mm2 rigid cables 16mm2 flexible cables .In : 63A & 100A (1. clause 2. 2. 3. 5mm 1 cat. 2 ways single pole 1 1 x 25A 250V~ 1 SF118 SF115 2 4 switches centre .Changeover switches 2 way. ref.3 Control & indication .double pole SF463 .four pole SF263 H.off changeover 1 5 2 x 25A 250V~ 2 SF219 SF219 2 4 6 8 double pole 2 x 63A 230V~ 4 SF263 NEW four pole 4 x 63A 400V~ 8 SF463 SF263 .off changeover double pole 1 5 1 x 25A 250V~ 1 SF119 2 x 25A 250V~ 2 SF218 2 4 6 8 switches centre . SF115 double pole 1 3 2 x 25A 250V~ 2 4 switch. centre off modular change over switches description manual change over switches for the control between two power supplies description characteristics width in I 17. 5mm cat.Selector switches voltmeters and ammeters description To provide command signals or program selection in electrical control schemes Application For domestic and commercial installations Connection capacity : .5 to 10mm2 . SK600 1 pole selector switch ! 20A 400V~ non spring return 3 2 pole selector switch ! # % 20A 400V~ non spring return 3 SK601 $ SK602 Voltmeter selector 3Ph&N 3 readings between phases 3 readings between phase & neutral null position (no 1 3 reading) V L1 L2 L3 N 10 6 2 12 L1 L2 0 L1 L2 L2 L3 L3 L1 L3 20A 400V~ 3 SK602 SK603 Ammeter selector 4 positions use in 3Ph&N reading by phase 0 position (no reading) should be used with current transformer (CT) 11 L1 L2 L3 3 4 10 2 L3 L2 20A 400V~ 3 SK603 A 9 0 L1 Step selector switch # ! % ! " 20A 400V~ 3 SK604 Key selector switch ! " 10A 400V~ 3 SK606 SK606 spare key for SK606 H.Rigid conductor : 1.Flexible conductor : 1 to 6mm2 Conform to IEC947-3 BS EN 60947-3 Isolating voltage : 500V~ Nominal current : 10-20A description characteristics width in 17.4 SK001 . ref. Indicator lights description Indicator lights and push buttons These products are used for remote controlling signalisation of any event in any electric installation (domestic.6mm2 flexible cable Standard conformity: IEC 62094-1 for indicator lights description characteristics width in I 17. connection capacity . new design and integrated label holder. tertiary & industrial) LED technology providing longer life.5 Control & indication . indicator lights with light 230V~ 1 x green 1 SVN121M SVN122M SVN124M SVN125M 1 x red 1 SVN122M 1 x blue 1 SVN124M 1 x clear 1 SVN125M SVN121M SVN126M SVN122M SVN127M 1 x green/red 1 SVN126M 3 x red 1 SVN127M H. ref.5mm cat.10mm2 rigid cable . 10mm2 rigid cables .Push buttons description 2 versions: .250V~ contacts: 1NO 1 SVN312M SVN413M contacts: 1NO + 1NC 1 SVN352M pushbuttons latching with indicator light contacts: 1NO green 1 SVN413M H.latching push buttons These versions with indicator lights are equipped with green or red diffuser.6mm2 flexible cables Standard conformity: IEC 60947-5-1 for push buttons IEC 62094-1 for indicator lights 68 44 description characteristics width in I 17. pushbuttons impulse without indicator light 16A .5mm cat.impulse push buttons . ref. (led technology) connection capacity .250V~ contacts: 1NO 1 SVN311M contacts: 1NC 1 SVN321M SVN311M contacts: 1NO+1NC (stop / start) pushbuttons impulse with indicator light contacts: 1NO green 1 SVN391M 1 SVN411M contacts: 1NC red 1 SVN422M pushbuttons latching without indicator light 16A .6 45 . 7 Control & indication .500V 0 .reading via CT SR 600 accuracy : 1. 150. ammeters description for domestic and commercial installations .100A scale : 0 .50A scale : 0 . 100. ref.600A 4 4 4 4 4 4 SM050* SM100* SM150* SM250* SM400* SM600* SM030* H. SM500* analogue voltmeter accuracy : 2% consumption : 2. 600A * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in I 17.reading via CT SR 101 .10mm2 rigid .reading via CT SR 051 .400A scale : 0 .5A 0 .250A scale : 0 .three phase : use of a voltmeter selector switch SK602 frequency : 50/60Hz connection capacity .Analogue voltmeters.5mm 4 cat.5VA 0 .30A analogue ammeter direct 4 4 4 SM005* SM015* SM030* SM500* analogue ammeter current transformer operated .single phase : direct connection .reading via CT SR 150 .15A 0 .reading via CT SR 400 . 400.6 mm2 flexible analogue ammeters for domestic and commercial installations direct reading : up to 30A indirect reading via current transformers: 50.reading via CT SR 250 .150A scale : 0 . 250.5% (full scale) scale : 0 . 8 34mmØ busbar entry = 40mm x 10mm .frequency: 50/60Hz Range of CT’s SR 051: 50/5A SR 101: 100/5A SR 150: 150/5A SR 200: 200/5A SR 250: 250/5A SR 300: 300/5A SR 400: 400/5A SR 600: 600/5A 21mmØ 22mmØ busbar entry = 30mm x 10mm H. on model) secondary current: 5A .can be mounted on DIN rail with adaptors description current transformers (CT)* for use with SM050 for use with SM100 characteristics ratio: 50/5 100/5 150/5 250/5 400/5 600/5 cat.can be mounted on copper busbar or on cable . ref. Their current on secondary circuit (0-5A) is proportional to the current on primary circuit class : 1 .Current transformers (CT’s) description Current transformers are used to feed analogue and digital ammeters. SR051 SR101 SR150 SR250 SR400 SR600 SR300 for use with SM150 for use with SM250 for use with SM400 for use with SM600 SR 051 Electrical connection (voltmeter) Electrical connection (ammeter) 1 3 5 7 9 0 L1L2 L2L3 L3L1 L1 L2 L3 0 100 200 300 400 500 V SM 500 SK 602 2 4 6 8 10 24 Current transformations (CT) Technical specifications Electrical characteristics .primary current: 50 to 400A (depend. as well as kWh meters. two or three phases (with or without neutral).9 Control & indication .5VA display voltage current . 50/60Hz accuracy : ±1% consumption : 4VA scale : 0 -500V voltage rating : 220/230V.35-480V . For monitoring of power generator. ref.accuracy: + 0.5mm cat. ref.accuracy + 0. . 50/60Hz accuracy : ±1% consumption : 4VA scale : 0-20A scale : 0-150A 4 Digital ammeters SM501 .reading via CT 400/5A (SR 400) 4 4 SM020* SM151* scale : 0-400A 4 SM401* SM020* .Digital voltmeters.Connection on current transformer (not provided).9 H.three phase : use of a voltmeter selector switch SK 602 .via c/t .direct .5mm 4 cat.Digital ammeters from SM 020 to SM 911 SM 020 : direct reading from SM 151 to SM 601 : reading via a current transformer (see below) * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in I 17.reading via CT150/5A (SR 150) . SM001* Multimeter voltage supply: 230/400V 50/60hz . as instantaneous.consumption: <0.secondary 0.5% . Enables the display 3 electrical values at the same time.7 digits 999999.5VA frequency . average or maximum (voltage and intensity per phase in RMS value).accuracy: + 2hz SM001 hour counter .reading via CT 600/5A (SR 600) scale : 0-600A 4 SM601* Digital multimeter Multimeter For monitoring the electrical network : single.range 40-80hz .1-6A .consumption: <0.primary 5-8000A . ammeters Digital voltmeters SM501 For domestic and commercial installations. * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in 17.5% . SM501 Digital voltmeter voltage rating : 220/230V. it measures the frequency and working time. kWh meters can be used for local metering of installations or monitoring of power consumption in individual machines.1500/5A CT operated dual tariff 4 EC320 4 EC321* EC321* hours counter 230V 50Hz 2 EC100* H. class 1 & class 2 accuracy .display with a LCD 7 digits (6+1) . ref.10 45 . All meters offer part (resettable) counter and total (nonresettable) counter(except EC050/ EC051) In addition meters are available for direct or CT operated with single or dual tariff. The range includes meters with pulsed output for remote indication or linking into an energy management system. EC111) 400V 50Hz 800mA to 80A single tariff 7 EC001 EC121* three phase direct reading EC310 400V 50Hz 800mA to 80A dual tariff 7 EC311* three phase CT operated 400V 50Hz 50 .5mm 1 cat.For CTs refer to page I.2 57 41 * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in I 17.1500/5A CT operated single tariff 400V 50Hz 50 . EC050 single phase direct reading 230V 50Hz 20mA to 32A 230V 50Hz 20mA to 32A pulsed output 1 EC051 EC050 single phase CT operation 230V 50Hz 100/5A CT operated single tariff 3 EC120 230V 50Hz 100/5A CT operated dual tariff 3 EC121* sealing kit for single phase kwh meters direct reading only (EC110. (second tariff is suitable for ‘time of use’ not ‘off-peak’) technical data .single and double tariff options .Kilowatt hour meters and hours counter description kilowatt hour meters measure the active energy used in an electric installation.with pulsed output .in accordance to IEC61036. 24V . note The transformers have a higher no load voltage. technical data . 12.33A .bells/buzzers : Max continuous duty < 30 minutes connection capacity .03A 1 SU213* buzzers 8/12V~ 4VA . ref.Buzzers : 78 dBA When a bell transformer is installed in an enclosure with mains voltage equipment.8V : 1A -12V : 0.11 Control & indication .secondary voltage : 8V.bell transformers are short . 12V. 24V~.0. bells and buzzers description provide safety extra low voltage 8.0.0.Transformers.35A 1 SU214* 230V~ 6.0.Bells : 85 dBA .5VA .67A 2 ST303* 230V/8 12V~50/60Hz 16VA .5mm cat. The stated voltages correspond to the voltages at nominal load 58 44 * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in I 17.5VA . 230V cable should be used on the secondary side of the transformer or extra low voltage cable should be sheathed within the enclosure.35A 3 ST305* 1 SU212* SU212* 45 230V~ 6.03A 1 SU215* SU214* H.24V : 0.circuit protected .67A bells 8/12V~ 4VA .8V : 2A -12V : 1.cable clamp type output . safety transformers 230V / 12-24V~ 50/60Hz 25VA 50/60Hz 4 ST312* 60VA 50/60Hz 6 ST315* ST312* bell transformers 230V/8~12V~50/60Hz 8VA . A thermal overload. in the primary windings.63A 13. by thermal protection in the primary winding.12 Subject to technical changes . Bell transformers Bell transformers are similar to safety transformers but the secondary voltages do not exceed 24 volts.08A 24 volts In = 1.8 volts 4kV 35°C ST305 16VA bell 230 volts 8 volts In = 2A 12 volts In = 1.4 volts 18. ! 8 "8 7 7 7! Technical specification Reference Nominal power Designation Primary voltage Secondary voltage U1 U2 ST303 8VA bell 230 volts 8 volts In = 1A U3 12 volts In = 0.33A 12.6 volts 27 volts 4kV 35°C thermal cut out in the primary winding number of products that can be operated simultaneously by a transformer transformer reference 8V ST303 12V 8 2 2 8V 16 5 5 ST305 12V 16 3 3 12V 25 - ST312 24V 25 12V 60 - ST315 24V 60 - power (VA) bell buzzer SU212 8/12V SU214 8/12V 8 3 3 H. their primary winding are electrically separated from their secondary windings and they are intended to feed safety extra low voltage (SELV) circuits < 50V.04A 14 volts 29 volts 4kV 35°C ST315 60VA safety 230 volts 12 volts In = 5.67A No load secondary voltage Galvanic insulation Max functional temperature Overload and S/C protection U2 U3 15 volts 21.5 volts 4kV 35°C ST312 25VA safety 230 volts 12 volts In = 2. they are also similarly protected against short circuits and overloads.25A 24 volts In = 2. ensures that if a short circuit or an overload occurs in the output it will not damage the device.Transformers Safety transformers These transformers are designed to ensure personal safety. input 1/10 V Functions : - protection overheating / overloads level indicator memory softstart mini. EV102 switch to “local” position EV012 EV002. max. The transformer shouldn’t be used with less than 75% of nominal load Halogen ELV (12 or 24V) via electronic transformer EV011 EV002.13 . EV004 EV100. level dimming speed speed at start / stop transition speed for level call Parameter setting : * EV011 : protection via integrated fuse.Dimmers. EV004 EV100. EV102 switch to “local” position Input 1/10 V. electronic protection for other products dimmers 300 W universal dimmers 600 W system dimmers universal dimmers 1000 W system dimmers 1-10 V pilots EV011 EV012 EV002 EV004 EV100 EV102 EV106 EV108 Subject to technical changes H.direct (capacitive/inductive load) .range overview FUTURE RELEASE functioning as a standalone product 0W 20W 60W 100W 300W 600W 1000W functioning in system : association of dimmers with 1/10V max 30 x 1kW EV102 pilot : switch to “master” position EV102 + n x EV100 or EV102 (slave position) EV 102 pilot : switch to “master” position Incandescent/halogen 230V EV011. 50 mA EV102 + n x EV100 or EV102 (slave position) EV 102 pilot : switch to “master” position EV102 + n x EV100 or EV102 (slave position) 1/10V control (output only) fluoro with electronic 1/10V ballast EV106 EV108 with scene inputs 300 W 600 W 1000 W Pilot 1/10 V Technical features Controls available EV011 EV012 EV002 EV004 yes yes 1 (EV004) yes yes EV004 yes yes EV004 EV004 EV004 - EV100 EV102 EV106 EV108 - on the product external with illuminated pushbutton yes input 1/10 V ambient lighting setting yes yes * yes yes - yes yes yes (slave) yes yes yes yes yes yes yes (slave) 2 levels yes yes (master) yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes 2 levels yes yes yes yes yes yes yes yes Types of outputs : . EV004 EV100. EV102 switch to “local” position Halogen ELV (12 or 24V) ferromagnetic transformer suitable for dimming. EV012 EV002. 14 . 300 W / VA 230 V / 50 Hz inductive load 1 EV011* capacitive load 1 EV012* 20 .min/max level setting .Dimmers Common characteristics : .dimming function 4 EV002* FUTURE RELEASE EV004* in addition to EV 002 features : . 99 % 4 EV004* Heat dissipation insert 0.incandescent 230 V . ref. 600 W / VA 230 V / 50 Hz ..5 LZ060 LZ060 H..products with automatic load recognition .control possible by illuminated pushbutton until 5mA.electronic protection against overheating and overload .recall mode with pushbutton.can replace a latching relay with dimming function Dimmers 600 and 1000 W : .Softstart (progressive start) to increase the working live of lamps .95) Enhanced universal dimmer 600 W FUTURE RELEASE 20 ..incandescent 230 V .last dimming level memorised . EV011* FUTURE RELEASE Dimmers 300 W for : .scene level setting 0 ..halogen 230 V ..control by several pushbuttons .universal products with automatic recognition of the load type (inductive/capacitive) . Dimmer 300 W : .halogen 230 V . override mode with switch .protection against overheating .Indicators : 230 V / overheating / overload * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in I 17.ELV halogen lamps supplied by ferromagnetic or dimmable electronic transformer (cos w t 0.ELV halogen lamps with : • ferromagnetic transformer (inductive load EV 011 ) • dimmable electronic transformer (capacitive load (EV 012 ) Universal remote control dimmer 600 W for : ..5mm cat. EV100* Universal dimmer 1000 W for : 230 V AC / 50 Hz 20 .dimming rise time (4s .dimming rise time for each scene .230V power supply/load error .ELV halogen lamps associated to electronic transformer (capacitive) Universal dimmer 1000 W with scene inputs FUTURE RELEASE 230 V AC / 50 Hz 20 ..control via pushbutton (local) ..min dim level (0. 250V AC1.remote control via 1/10V (slave) .99s) .incandescent ..49%) .99%) .control of the other dimmers as 1/10V (master) • Display to show the dim level and to set the parameters: . ref.5mm cat.ELV halogen lamps associated ferromagnetic transformer (inductive) .1 000W 1/10V-input/ output (max..ELV halogen lamps associated to ferromagnetic transformer (inductive) . potential free 5 EV102* EV102* • Functional mode selection via local switch : . contact is opened.fall time when switching OFF (1s.. 50mA.control via pushbutton (local) .230V halogen lamps .scene working mode : recall or override mode • Output contact to display the dim state (load is OFF.overload / overheating Load type : .230V halogen lamps .Dimmers * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in I 17...99s) .99s) .incandescent .230V power supply / load error .rise time when switching ON (1s. if load is dimmed the contact is closed) • LED indication : .max dim level (51. 30 EV100 / EV102) defined via the local switch Contact output : 1 NO.scene level ..ELV halogen lamps associated electronic transformer (capacitive) H.15 Control & indication .1 000W 1/10V-input 5 EV100* • Functional mode selection via local switch : .overload / overheating Load type : ..remote control via 1/10V (slave) • Min/Max setting via potentiometer • LED indication : .. 250V AC 10A AC1 potential free 4 EV106* FUTURE RELEASE 1/10V pilot dimmer with scene input In addition to EV106 features : • Scene inputs used for override (3 levels) or simple recall (2) • For each scene .16 . contact is opened.and scene mode (recall or. Use : to control lighting in meeting and conference rooms. 30) • To dim electronic ballasts • Wiring of illuminated pushbuttons possible up to 5mA • Display to show the dim level and to set the parameters: .Setting of rise time and fall time EV 108 pilot dimmer .Contact output for state information .Display to show the dim level and for parameter setting .min dim level (0.dimming rise time . * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in I 17. It is used to switch ON/OFF the electronic ballast 230 V M / 50Hz 1/10V .scene level . if load is dimmed the contact is closed).override) 4 EV108* EV108* H. dim level (51.max. CEI 669-2-1. EN 50082-1.5mm cat. CEI 669-1.Min/max level setting . ref.Scene inputs used for override (3 levels) or simple recall (2 levels).. or in restaurants Dimmers conform to standards EN 50081-1.To control several dimmers or electronic ballasts via the 1/10V output .Wiring of illuminated push buttons possible up to 5mA .Dimmer system : 1/10V pilots EV 106 and EV 108 pilot dimmers .interface Output /max 50mA contact output : 1NO.Dimming rise time setting ..99%) Contact output to display the dim state (load is OFF. EV106* FUTURE RELEASE 1/10V pilot dimmer • To control EV100 and EV102 (max..49%) .dimming rise time (4s .99s) . lux.220° .Motion detectors. test and override ON/OFF Corner mounting accessory White Corner mounting accessory Charcoal grey Corner mounting accessory Titanium grey EE855 EE856 EE857 EE806 . 20%. sensitivity.Detectors can be mounted in corners utilising the relevant corner mounting accessory. . -> 15 min (30 min with IR remote control). They automatically switch on lighting when movement is detected. sensitivity are achieved locally.220°/360° 16m frontal & 10m left/right 16m frontal & 10m left/right & 6m diameter down 5 to 1000 lux pulse. 5s. detection angle used (for Twin model). max.It’s also possible to set the detectors with an IR remote control which provides speed & convenience when setting final adjustments.220° . They turn off the circuit after the preset duration. . Two Models: Products are equipped with Fresnel lenses that allow high frontal detection performance and downwards detection: . 100% + 10 m 10 m lux IR Remote Control Detector 220° White EE860 EE861 EE862 EE871 Detector 220° Charcoal grey Detector 220° Titanium grey evolution Line Detector 220/360° White Detector 220/360° Charcoal grey EE870 EE871 EE872 EE806 Control & indication H.5 m Ø6m 8m 16 m α = 220/360° description characteristic features detector .100% cat.17 EE872 Detector 220/360° Titanium grey Remote control IR Sets time. 16 m 4m 2. ref. .220° frontal detection zone . lock/unlock. They also provide significant savings in lighting power consumption by illuminating only when necessary.Twin 220°/360° to detect in a frontal & downwards zone.IP 55 Premium detectors These devices are made forautomatic control of lighting in both the residential and private/public industry sectors. via potentiometers.Time. 20% Max. Min. They bring comfort and enhance security for exterior accesses to residential homes. 1 sec 5 sec .220°/360° IP55 230 V~ 50 Hz/60Hz 16 A AC1 potential free 2300W incandescent 5s 5 min 15 min auto test Detection range: . garages.15 min Lux 5-1000 EE870 Lux Timer Sensitivity description comfort Line Sensitivity: Min. Lux. Motion detectors . ref. fixing spring and protection cover) . .Movement detector for the automatic control of lighting in indoor circulating zones. AC1 1000w Incandescent EE804 EE804 white flush mount 10A.Setting The timer and the lux level are defined via potentiometers . They automatically switch on lighting when movement is detected and light is needed.Output Potential free relay contact 10A.indoor 360 white surface mount o 10A.Mounting of EE805 connection system conform of false ceiling installation standards (cable clamp. AC1 1000W description characteristics cat.Motion detectors description These devices are made for automatic control of lighting in both the residential and private/public industry sectors. AC1 1000w Incandescent EE805 EE805 H. . Surface mounted (EE 804) or flush fitting (EE 805).18 . They turn off the light after a preset duration. inform the Master module which then commands the light depending on luminosity.Natural and artificial light measuring . override and duration of lighting.Models with 1 or 2 channels . Innovative technique The patented double lens technique ensures a very precise detection on 360° of a person moving on an area up to 13 x 7 m.Override entry or manual dimming . natural and artificial light measure rotating front lens H. Rotating and adaptable According to the architectural constraints.Detection zone of 360° on 13 x 7 m . When no more presence is detected the module will return to the automatic mode after the pre-selected time delay. The light intensity constantly remains fixed according to the preselected set point. The presence regulator (EE812) adapts to the artificial light depending on natural light and presence. Whether the regulation of the light depends on occupancy or simply to switch on the lights depending on presence and ambient luminosity. time delay and manual dimming. rectangular capture hospitalsand corridors. The integrated luxmeter makes it also possible to differentiate the proportion of natural and artificial light.Basic lighting mode : for safety in hotels. Regulation with constant lighting: nearly a must in all open-plan offices. homes. Override The command entry on the 2 channel presence detector (EE811) and on the presence regulator (EE812) allows the activation Benefits : . the Hager presence detectors offer the necessary flexibility for each application. Adjustable from 5 to 1200 Lux. Settings : lighting. then released after 15 minutes for the EE812 model.Basic lighting mode on presence regulators EE812 . the detection zone can be adjusted with precision thanks to the rotation of lens on 90°. Manual dimming is also possible via the same command entry on the presence regulator. The time delay begins once no more presence is detected. An effective and pleasant lighting level can be carried out easily and quickly with the range of Hager DIN rail dimmers.19 Control & indication .Comfortable energy saving …with the presence detectors For the control or the regulation of lighting depending on presence and natural light The new Hager presence detectors with double lens technique are adapted to all architectural requirements. The zone detector will switch on the lighting channel in case of presence. The Slave module will for example detect a presence.Wide setting possibilities . Ventilation. ambient temperature or alarms can also be piloted exclusively by the detection of a movement thanks to the second channel. This facility is ideal for presentations during which the room must completely or partially darkened. A push button connected on the override entry makes it for example possible to turn-off the light or reduce it to the desired level during a presentation. the lighting/variation can also be set manually via the command entry on the presence regulator. The light will then be reduced to the selected value between 0 and 50%. Master and slave : extended coverage The presence detectors can be linked together for corridors or large premises. The time delay of the lighting and presence channel can comprehensive be selected individually from 30 settings seconds to 1 hour.Regulation of presence / light .Master/Slave function of a lighting circuit (for example via a push button). Combination of a presence area and a motion area. The presence area is especially interesting in offices.Presence output potential free relay.1 channel detector Direct control of a light load or used as a slave for detection area enlargement.lux level and On delay define via potentiometers .Input for slave (EE810) and/or dimming pushbutton in order to modify the setpoints .3 functional modes : no regulation. ref.2 channels detector . where the motion area may be used in long corridors. EE811 and EE812 High performance presence detector that will be used in premises or in passage areas.surface mounting accessory . Head rotation for detection area adjustment Settings via potentiometers Applications EE810 .Lux level and ON delay setting via potentiometers .Lux level.input slave .Light relay output for direct control of a light load description Light regulator with 1/10V output in order to control electronic ballasts and/or Hager dimmers EV100/EV102. where they increase comfort and reduce drastically the energy costs. characteristics cat. EE810 .230V input used with pushbutton to toggle the light channel state or with slave in order to enlarge the detection area • Relay output presence channel .20 . on delay setting for light channel and presence channel via potentiometers .recessed 230V~ 50Hz μ10 A AC1 1/10V 50mA 230V input 50Hz EE812 230V~ 50Hz μ16A AC1 230V input 50Hz μ2 A AC1 EE811 EE813 Detection Zone 6m 2. regulation with remote setpoint EE813 : accessory to surface mounting presence detector 1 channel • relay output light channel .Input for slave (EE810) and/or remote push button.lux level and on delay (duration or pulse) defined via potentiometers • Slave output for association with EE811/EE812 Lux OFF 230V~ 50Hz μ16A AC1 100W triac output 0.Light regulator 1/10V .5m EE813 WE741 H. .Presence detectors High performance detectors EE810.Lux level. . On delay for light channel and min level via potentiometers .on delay presence defined via potentiometer Presence detector 1/10V • Relay output used to switch ON/OFF the electronic ballast • 1/10V output used to dim an electronic ballast or Hager dimmers EV100/EV102 • 230V input used with push button to toggle the channel or change the dimmed level or with slave in order to enlarge the detection area • 3 functional modes defined via potentiometers mode 1 : no regulation mode 2 : regulation with local set point via potentiometer mode 3 : regulation with set point defined via a remote push button Accessory mounting accessory . EE812 .8A EE810 Presence detector 2 channels • Relay output light channel .Test mode in order to set lux level and the detection pattern EE811 . Detector especially dedicated for energy saving and comfort purpose. regulation with local setpoint. au H.) Energy Distribution Enclosure systems Wiring Accessories + Building Automation Cable management First-class quality. For more information on the available ranges please go to wiring accessories section K.hagerbr. you need to move ahead of them and embrace the technology of tomorrow.com. www.21 .matching glass splashbacks to glass power points.make the switch in your beautiful home wiring accessories + building automation (sec. flat screen TVs to flat panel glass switches. Create a modern look in your home or office . The classic and linear appeal of real glass has never been more achievable in so many places at once. real glass elegance To keep up with today’s trends. K. including the management of lighting and heating. H. delay timers. thereby saving unnecessary usage of energy.Energy distribution Modular devices The scheduling of energy management solutions.22 . help to make life easier while also saving energy. contactors. latching relays. Digital and analogue time switches. kWh meters and CTs complete the offer. Various loads are only switched on when they are actually needed. 2 channel Time switches & light sensitive switches selection chart I.1 Modular devices .2 I.4 I.14 I.11 I.16 I.8 I.7 I.Contactors I.17 Noise free contactors Choice of contactors Latching relays Latching relay auxiliaries Interface relays Delay timers Time lag switches Analogue time switches modular Analogue time switches 72 x 72mm Digital time switches selection chart Digital time switches Light sensitive switches Astronomical time switches Light sensitive switch .12 I.3 I.15 I.9 I.7 I.13 I.10 I. 4kW 25A-250V 4kW/1. The use of LZ060 (heat dissipation inserts) between all contactors installed type or between contactors and adjacent devices is recommended options contact choice .2 45 . .5kW/3.4kW 40A-400V 8.4kW 25A-250V 4kW/1.4kW 25A-250V 4kW/1.4kW 63A-250V 13kW/5kW 2 3 3 2 2 3 3 3 3 2 3 1/2 1/2 ES320 ES340 ET341## ES420 ES420A# ES440 ES463 ES480 ES490 ES450 ES470 EP071 LZ060 ES320 4NO 230V 230V 230V 230V 230V 4NC 230V 230V 2NO+2NC 230V ES463 230V auxiliary suitable for 20A contactors 2A-250V heat dissipation insert I.the control voltage required All contactors carry an Ith load rating.normally closed (NC) LZ060 heat dissipation inserts auxiliary 25A contactors will except auxiliary EP071 contact 58 37 description coil power AC circuit 50/60Hz 50/60Hz 230V 230V AC1/AC3 width in I cat.the characteristics of the load .the nature of the supply . 17.Contactors contactors for the remote switching and control of power circuits (25A-63A AC1) override contactors allows : permanent ON permanent OFF # manual override ## auto override technical data the choice of contactor depends upon a number of parameters e.5mm ref.g.4kW 25A-250V 4kW/1.4kW 1NO+1NC 230V 1NO+1NC 24V 2NO 2NO 2NO 230V 230V 230V 230V 230V 24V 24V 2NC 230V ES240 3NO 230V 230V 25A-400V 13kW/4kW 40A-400V 25kW/10kW 40A-400V 25kW/10kW 25A-400V 13kW/4kW 25A-400V 13kW/4kW 40A-400V 25kW/10kW 63A-400V 40kW/15kW 40A-400V 25kW/10kW 63A-400V 40kW/15kW 25A-250V 4kW/1.4kW 25A-250V 4kW/1. 1 1 1 1 1 1 1 3 3 1 1 1 ES110 ES110A# ES210 ES239 ES220 ES220A# ET221## ES240 ES263 ES224 ES224A# ES230 contactors 1NO 1NO 25A-250V 4kW/1.the current it is switching .normally open (NO) .4kW 25A-250V 4kW/1.4kW 25A-250V 4kW/1.5kW 63A-400V 13kW/5kW 25A-250V 4kW/1.4kW 25A-250V 4kW/1. These contactors are DC driven with integrated rectifier allowing DC or AC voltage control.5mm cat.Hum free .Suitable for use with PLCs 60 35 5.Low noise switching . heating.Noise free contactors Noise free Contactors for the remote switching and control of power circuits (25A . ref.3kW 1 ESN220B 230V 40A-400V 8.7kW 3 ESN240B 230V 63A-400V 13. contactors 2NO 20A-230V 4kW/1.Position indicator .Coil protection (varistor) . lighting. ventilation. pumps and other building automation systems.3kW 2 ESN444B auxiliary suitable for 25A contactors 6A-250V 1/2 ESN071B heat dissipation insert 1/2 LZ060 I. Advantages .63A AC1) Eg.7kW/3.3kW/5kW 3 ESN263B ESN420B 3NO 230V 25A-400V 16kW/4kW 2 ESN320B 230V 40A-400V 26kW/11kW 3 ESN340B 4NO 230V 25A-400V 16kW/4kW 2 ESN420B 230V 40A-400V 26kW/11kW 3 ESN440B ESN440B 230V 63A-400V 40kW/15kW 3 ESN463B 4NC 230V 25A-400V 16kW/4kW 2 ESN430B 3NO+1NC 230V 25A-250V 5kW/1.3 Modular devices .5 43 description type coil AC 50/60Hz or DC 230v power circuit 50/60Hz AC1/AC3 width in 17. e. Type of load Loads are categorised into various AC ratings. type of load supplied etc. e *Utilisation category **ACx* The Utilisation category defines the intended application and is characterised by .7kW Noise free 3 module (2 pole) 63A Std range Noise free 3 module (4 pole) 63A Std range noise free ES470 ES263 13kW 13kW ESN263B 13. Slightly inductive loads (i.e.Choice of contactors Heating The choice of the contactor depends on the mechanical stress (number of operations) and on the electrical heating load i.e.3kW ES490 ES463 13kW 40kW ESN463B 13.3kW 40kW Load type I. resistive elements.7kW 8.5kW 8. infra-red element. Hager contactors have been tested to IEC61095 which defines the current ratings and utilisation category as follows: *I is the conventional free air thermal current and is the maximum th I is a “dynamic current” allowing the contacts to open and close for a given load utilisation category.a voltage . ambient temperature. *I * e I is the rated operational current.the current I . Choice of contactors The choice of contactor is dependent upon many parameters i.) 230 Maximum number of operations 200 000 AC1/AC7a 100 000 200 000 AC1/AC7a 400 100 000 25kW 26kW ES440 ES480 8.a power-factor e Hager contactors are approved according to EN/IEC 61095 for the utilisation category AC-7a and 7b. The value of I must be at least equal to the maximum value of the current I . convectors.) 230 100 000 200 000 AC1/AC7a 400 100 000 4kW 4kW 13kW 13kW 5kW 16kW 16kW 8.5kW 8. e This value takes into account: .4 Subject to technical changes . heating) 1 module 20A Standard range ES110 ES210 ES220 Voltage (a.9 Please consult us if you require help selecting a suitable contactor.eg. value of test current used during temperature-rise tests.7kW Maximum number of operations 200 000 AC1/AC7a ET221 ES224A ES110A ES239 ES220A ES224 ES230 4kW ESN220B ES320 ES420 ES420A ES450 4kW ESN320B ESN420B ESN430B ESN444B 5kW ES240 ESN240B Noise free 2 module 20A Std range Noise free 3 module (2 pole) 40A Std range Noise free Load type 3 module (3&4 pole) 40A Std range ES340 ET341 Voltage (a.) th e Maximum load in kW (AC1 / AC7a .c. Temperature derating Derating factor between 40oC and 55oC = 0. th e th Heat dissipation inserts To avoid any product overheating it is strongly advised to insert a heat dissipation space every 3 contactors up to 40oC and every 2 contactors from 40 to 55oC.the rated operational voltage Ith (The value of I must be at least equal to the maximum value of the current I . household appliances and similar applications) are given the category AC-7a. I is a “static current” with no switching involved. Approved to IEC 60947-4 for the utilisation categories ACI and AC3 For AC1 and AC3 ratings see chart below. size of contacts.3kW 13. operating voltage.c. number of operations.5kW ESN340B ESN440B 8. ) 230 Maximum number of operations 300 000 AC3/AC7b 150 000 300 000 AC3/AC7b 400 150 000 10kW 11kW ES440 ES480 3.000 in that case select an ES 240 to control a load of 4.c.5kW ESN340B ESN440B 3.3kW 1.4 kW (single phase 230V) Motors (AC3) Single phase 230V Three phase 400V L1 U M M L2 V Maximum load in kW (AC3/AC7b-eg motors) 1module 20A Standard range ES110 ES210 ES220 Voltage (a.4kW 4kW 4kW 1.5kW 3.5kW 3.5 ES470 ES263 5kW 5kW ESN263B 5kW 5kW ES490 ES463 5kW 15kW ESN463B 5kW 15kW Load type Subject to technical changes .7kW Noise free 3 module (2 pole) 63A Std range Noise free 3 module (4 pole) 63A Std range noise free Modular devices I.4kW 1.7kW Maximum number of operations 300 000 AC3/AC7b ET221 ES224A 1.3kW ES320 ES420 ES420A ES450 1.4kW 4kW 4kW 3. 100 operations per day (1 opening + 1 closing = 2 operations) mechanical life = 10 years total number of operations: 200 x 100 x 10 = 200.c.4kW ES240 ESN240B Noise free 2 module 20A Std range Noise free 3 module (2 pole) 40A Std range Noise free Load type 3 module (3&4 pole) 40A Std range ES340 ET341 Voltage (a.) 230 150 000 500 000 AC3/AC7b 400 150 000 1.4kW ESN320B ESN420B ESN430B ESN444B 1.Single phase Three phase U R R example: function of a heating installation 200 days/annum.7kW 3.4kW ES110A ES239 ES220A ES224 ES230 ESN220B 1. 5 μF 7 μF 4.5 μF 10 μF 18 μF 90 66 50 43 30 18 15 13 18 14 10 35 30 17 17 15 8 67 49 37 32 22 7 7 4 6 6 4 25 15 12 12 7 7 90 66 50 43 30 18 15 13 18 14 10 35 30 17 17 15 8 67 49 37 32 24 8 8 5 8 8 4 35 20 19 17 10 9 125 92 69 60 85 45 40 30 44 40 30 66 56 31 33 28 15 93 69 51 45 90 48 48 31 48 48 30 100 52 50 50 26 25 180 133 100 86 120 60 55 40 60 54 40 103 85 47 51 42 23 135 99 75 64 140 73 73 47 72 72 46 140 75 72 70 38 36 50 33 26 20 13 10 6 4 2 50 33 26 20 13 10 6 3 1 50 33 26 20 13 10 6 4 2 50 33 26 20 13 10 6 3 1 125 83 66 50 33 25 16 10 5 100 65 53 40 26 20 13 8 4 175 116 93 70 46 35 23 14 7 125 85 66 50 33 25 16 10 5 I.Choice of contactors Contactor Selection (lighting) The table below indicates the number of lamps (or dual fittings) that can be connected to each pole of the contactor on 230V 50hz curcuits.parallel compensation (number of double fittings) Single electronic ballast 2 x 18W 2 x 36W 2 x 58W 18W 36W 58W Double .5 μF 4.electronic ballast (number of double fittings) Discharge lamps Low pressure sodium vapour lamps (compensated) 35W 55W 90W 135W 180W High pressure sodium vapour lamps (compensated) 50W 70W 110W 150W 250W 400W 1000W Metal Halide vapour lamp (compensated) 35W 70W 150W 250W 400W 20 μF 20 μF 30 μF 40 μF 45 μF 8 μF 12 μF 12 μF 20 μF 36 μF 45 μF 100 μF 6 μF 12 μF 20 μF 32 μF 45 μF 5 5 4 2 2 8 6 5 4 2 2 1 8 6 3 2 1 1 1 1 6 4 4 1 5 2 1 0 0 5 5 4 2 2 8 6 5 4 2 2 1 8 6 3 2 1 1 1 1 6 4 4 1 1 6 3 1 1 1 10 10 8 5 4 25 18 15 13 8 6 4 31 15 9 5 3 11 11 8 5 4 18 13 11 11 6 4 2 36 18 11 6 6 15 15 11 7 6 35 25 18 15 10 8 5 42 20 16 7 5 11 11 8 5 4 26 19 13 16 10 6 3 50 25 15 9 8 2 x 18W 2 x 36W 2 x 58W 4. 1-module Type Lamp power Maximum 25A / 20A capacitor value per Standard Noise free Esxxx ESNxxxB fitting 2-module 25A Standard Esxxx Noise free ESNxxxB 3-module 40A Standard Esxxx Noise free ESNxxxB 3-module 63A Standard Esxxx Noise free ESNxxxB Incandescent lamps Tungsten & halogen lamps 40W 60W 75W 100W 150W 200W 300W 500W 1000W Fluorescent tubes Energy saving lamp Compact Fluoro lamp Single non compensated Single parallel compensation 11W 15W 20W 23W 18W 18W 36W 58W Double .6 Subject to technical changes . which are connected with the latching relay. remains possible. the next impulse returns it to its reset (original) state. an impulse control directly to the latching relay’s coil is possible with the auxiliary contact EPN 053. EPN050* 45 auxiliary for centralised control 24 to 230V AC " EPN 050* I. The pulse can be provided via a push button or switch.7 Modular devices FUTURE RELEASE . connection capacity .5mm 0.10 rigid cables . time switches or limit switches.Latching relays description for control of lighting circuits in private buildings.g. Connection capacity 10I rigid cables 6I flexible cables * Please check availability with your local Hager B&R sales office at time of ordering* description characteristics width in 17. Latching relays operate when pulsed by a signal voltage.5mm 1 cat. Connection latching relay + auxiliary Several auxiliaries can be combined with the latching relay. ref. The first impulse sets the relay into its set (opposite) state. EPN510* latching FUTURE RELEASE relays 1NO 2NO 230 110 16A-250V 1 EPN520* EPN510* 24 12 16A-250V 1 EPN524* 1NC + 1NO 230 110 16A-250V 1 EPN515* Latching relays auxiliaries Auxiliaries for centralised control.5 cat. Auxiliary for control by maintained contact. The EPN 052 allows a generic central control of individual central on/off EPN 050 Auxiliary contact A remote signalling can be realised with the auxiliary contact EPN 051. The EPN 050 allows the centralised control of several light sources which can be turned on or off simultaneously the separate switching by pushing the pushbuttons. When control devices with permanent impulse are externally driven. ref.6 flexible cables 68 44 * Please check availability with your local Hager B&R sales office at time of ordering* description type coil Vac 50/60Hz 230 coil Vdc 110 power circuit AC1 16A-250V width in 17. small industry buildings and administration buildings. e. description characteristics width in I 17.5 cat. ref. ref.Latching relays auxiliaries cont.5mm 0.4mm2 flexible cables description characteristics width in I 17.5mm 1 cat.8 . EN145 interface relays ELV/LV 1 way output: 1 changeover A1 1 coil voltage: 10 to 26V AC/DC A2 2 4 contact max. EPN051* auxiliary contact FUTURE RELEASE ! 2A 250 V AC " EPN051* FUTURE RELEASE auxiliary for multi levelled centralised control ! !! 24 to 230V AC 0.5 EPN052* ! !" EPN052* auxiliary for control by maintained contact FUTURE RELEASE 24 to 230V AC 0.5 EPN053* " EPN053* Interface relays description to interface between low voltage and extra low voltage circuits to ensure galvanic insulation between LV and ELV to 4kV application interface between fire alarm.6mm2 rigid cables .. 10mA .12V DC EN145 I. 5A 230V~ min. burglar alarm and other ELV systems and main distribution circuits connection capacity . 9 Modular devices 6 .adjustable time ON B .adjustable time OFF A .delay off E . ref.1s to 10hr T 1 Output S 1 Delay OFF Control Cd 1 c/o contact 8A / 230V~ AC1 time delay T : 0. Applications For timing and automation in domestic and commercial premises.delay on C . ventilation. lighting.1s to 10hr T 1 EZN002 EZN001 Output S Adjustable time ON Control Cd 1 c/o contact 8A / 230V~ AC1 time delay T : 0.10mm2 rigid description characteristics width in I 17. time clock etc. watering.1s to 10 hours.Delay timers Description To provide all types of automatic control i. machine preheating.) and the timed output used to control the application.OFF 1 c/o contact 8A / 230V~ AC1 time delay T : 0.1s to 10hr 1 EZN005 Multifunction 6 individual functions including : D . Technical data Voltage range : 12 & 24 to 48V DC 12 & 24 to 230V AC Adjustable: time delay from 0.5 . LED indicator complies with EN 60669-2-1 Connection capacity : 6mm2 max flexible 1.1s to 10hr 6 1 EZN004 Output EZN006 Symmetrical flasher Control +@ Output 5 1 c/o contact 8A / 230V~ AC1 time delay T : 0. automatic door and visual audible indication. The input signal can be via various switching devices (push button.1s to 10hr 1 EZN003 Output S T Timer Control +@ 5 1 c/o contact 8A / 230V~ AC1 time delay T : 0.1s to 10hr 1 EZN006 I.symmetrical flasher . cycle control etc.e. latching switch. EZN001 Delay ON Control Cd 1 c/o contact 8A / 230V~ AC1 time delay T : 0.5mm cat.timer F .ON . 10 . for staircase. EMN005 incorporate a pre-warning of switch OFF to improve the safety for users and a double delay function: 30s to 10min or 1hr by pressing the push-button for more than 3s. ref.Time lag switches Description Time lag switches provide control of lighting circuits with automatic switch-off after a pre-set time.double delay mode 30s to 10min or 1hr .250V AC1 2300W incandescent halogen and fluoro EMN001 I.pre-warning mode . EMN005 FUTURE RELEASE Multifunction staircase time lag switch supply voltage : 230V 50/60Hz 16A . (e. Complies with EN 60669-2-1 description characteristics width in I 17.g.double delay with pre-warning mode 2300W incandescent halogen and fluoro FUTURE RELEASE Add-on block pre-warning device EM002 voltage rating : 230V 50/60Hz restart facility pre-warning to switch-off by dimming the lights to 50% level 24s prior to switch off output power : 1000W incandescent 1000W halogen not suitable for use with discharge lamp supply voltage : 230V 50/60Hz 2 EM002 Standard staircase time lag switch 1 EMN001 adjustable time delay setting: 30s until 10min retrigger 16A .basic staircase time lag switch . Compact design with a 2 position switch permanent/ timed lighting implementation facility.5mm cat.250V AC1 1 . corridors lighting). permanent ON On 2 and 3 module devices : . Applications Domestic and commercial premises.5mm cat.automatic . ref.15 min and 2 hours on the daily+weekly version Connection capacity : 1 to 4mm2 * Please check availability with your local Hager B&R sales office at time of ordering* description characteristic width in I 17.automatic . To improve comfort and save energy.manual override : On 1 module devices : . DIN rail mounting Complies with EN60730 Technical data .programming by captive segments.permanent ON .permanent OFF Minimum switching time: .15 min for daily versions .Analogue time switches modular Description Electromechanical time switches 1 channel for daily or weekly programming. heating. EH010 Analogue time switches modular compact 230 V 50 Hz 1 NO 16 A .250 V AC1 24hr without battery reserve 1 24hr reserve: 200hrs 1 EH011 EH010 Analogue time switches standard modular version 230 V 50 Hz 1 NO changeover 16 A . shop windows etc. To control lighting.2 hours for weekly versions .11 Modular devices 7day reserve: 200hrs 3 EH171 .250 V AC1 24hr without battery reserve 3 EH110 24hr without battery reserve 2 EH210* EH111 24hr reserve: 200hrs 3 EH111 FUTURE RELEASE FUTURE RELEASE 24hr reserve: 200hrs 2 EH211* FUTURE RELEASE EH210* 7day reserve: 200hrs 2 EH271* I. . household appliances. Analogue time switches 72 x 72mm description for daily or weekly programming. heating. commercial premises technical data . ref.programming by captive segments .manual override with automatic return to programmed . . 1 channel daily cycle supply : 230V 50/60Hz without battery reserve 24 hr dial Manual override EH710 with battery reserve EH711 24 hr dial Manual override EH711 1 channel weekly cycle supply : 230V 50/60Hz with battery reserve 7 day dial Manual override EH771 EH771 I. household appliances.output: voltage free changeover contact 16A/250V daily version: programming in steps of 10 minutes. 1 channel time switches for the control of lighting.suitable for surface.12 . Minimum time between 2 switching intervals : 20min weekly version: programming in steps of one hour. flush or DIN rail mounting . shop windows etc. applications domestic. To improve comfort and save money.operating reserve: 200hrs after connection for 120hrs .minimum time between 2 switching intervals : 2hrs .switching accuracy : 10min description characteristics cat. 13 Power interface Programming .Module width display astro pulse cycle overrides holiday random operating cycle program steps contacts/ channels program key day-light saving external input keyboard locking hour counter EG010 1 1 6 EG071 1 1 20 EG103E 1 2 56 Digital time switch .selection chart EG203E 2 2 56 EG493E 4 4 300 EG293E 2 4 300 EG403E 4 4 300 EE180 1 2 56 Subject to technical changes EE181 2 2 56 I. permanent & temporary over ride & pulse .software programming option . EG293B 2 EG103E 2 EG203E 4 channels weekly time switch 4 EG403E 2 channels yearly time switch 4 EG293B EG203E 4 channels yearly time switch 4 EG493E Programming key EG007 Programming key for EG103E / EG203E EG005 Keypad locking key for EG103E / EG203E EG004 EG403E Interface and software for computer PC with software on CD and USB EG003U I.operating reserve 5 years .5mm 1 cat. ref EG010 1 channel daily cycle 5 adjustable pre-recorded programs : 6 commutations max per day (3 ON and 3 OFF) 230V 50/60 Hz capacity : 20 program steps 230V 50/60 Hz 1 channel weekly cycle 1 EG071 1 channel weekly cycle EG071 2 channels weekly cycle capacity: 56 program steps version delivered with key EG005 capacity: 56 program steps version delivered with key EG005 voltage rating: 230V~ 50/60 Hz output: 3 changeover contacts 10A . EG493E.20 program steps (EG070) 2 module time switch .keypad locking key EG004 .bar graph for quick description characteristics program overview .automatic summer/ winter adjustment width in I 17.operating reserve 5 years 300 program steps . irrigation.1 channel cycle .250V~ AC1 voltage rating: 230V~ 50/60 Hz output: 3 changeover contacts 10A .holiday mode .operating reserve 3 years .Digital time switches description for the control of lighting.manual over ride .ability to download program onto multiple time switches via EG003U .back lit display . pumps.manual over ride & pulse .ability to download program onto multiple time switches via EG005 . schools. 1 module time switch .250V~ AC1 1 NO 1NO contact : 10A 250V ~ AC1 delivered with programming key voltage rating: 230V~ 50/60 Hz output: 2 changeover contacts 10A .programmable without mains supply .5 pre-recorded (adjustable) programs (EG010) .250V~ AC1 1NO contact: 10A 250V ~ AC1 delivered with programming key for EG403E.etc. school bells.56 program steps . applications domestic and commercial premises.14 .automatic summer/ winter adjustment 4 module time switch .impulse control . EE180* 2 channels 230V AC 50 Hz 2 changeover contacts 16A AC1 operating reserve lithium battery 5 years EE181* EG005 I.off: permanently switched off .250 V AC 1 sensitivity : 2 ranges .Anticipation ON . This device controls lighting circuits in relation to ambient light.Astro program and expert program with individual Astro program steps .Programming of holidays period . display lighting. ref.auto: normal operating mode . Light sensitive switch delivered with : a separate surface photo electric cell EE003 (EE100) a separate flush photo electric cell EE002 (EE101) Compact light switch IP 55 / integrated cell Voltage rating : 230 V AC +10-15 % 50 Hz output : 1 changeover 16 A . switch 5 EE110* weekly cycle electronical program free setting 3 EE171* EE110* FUTURE RELEASE delivered with key EG005. Front cover sealability Applications Street lighting. Protected cable clamps capacity : rigid : 1.Programming for day or group of days (same concept as our existing clocks with key) .Maintained ON . The hager range is composed of two Astronomical time switches EE180/EE181 The range offers the following features : .5 to 100 lux . 4 position override switch allowing: .15 Modular devices Astronomical time switch (weekly cycle) 1 channel 230V AC 50 Hz changeover contact 16A AC1 operating reserve lithium battery 5 years EE180* .on: permanently switched on .test: setting mode for easy adjustment output : 1 changeover AC1 contact 16A AC1 230V 8A AC1 (EE702) Maximum distance : 50m between photocell & controller Must be used in conjunction with a suitable rated contactor Astronomical time switches.5mm cat.Weekly program * Please check availability with your local Hager B&R sales office at time of ordering* description FUTURE RELEASE characteristics with in I 17.Light sensitive switches Astronomical time switches Light sensitive switches A photo-electric cell measures the light level and in conjuction with the relay provides ON / OFF control of a circuit.Programming of the lighting control .Automatic change of winter / summer time .5 to 10mm2 flexible : 1 to 6mm2 LED shows status of changeover contact.50 to 2000 lux 3 3 EE100* EE101* EE101* normally open contact 16A AC1 2-1000W incandescent switching delay either fixed or adjustable (1s .120s) - EE702 EE702 FUTURE RELEASE Programmable light sensitive switch with surface cell daily cycle electromech. illuminated signes etc.Programming via the PC software and the associated interface (EG003) . based on user settings.Temporary overrides . Light sensitive switches 2 channel Light sensitive switch, 2 channel up to 20000 Lux By controlling exterior and interior light sources, the light sensitive switches enable great energy savings. Providing consistent & controlled lighting across all areas while making the most of the natural light source. Examples of use: offices, classrooms, storage rooms, production areas... Characteristics “Auto-Test”switch: - “Auto” position, channel switching is 30s, - For each channel: - luminance threshold setting - state display - switch: manual override, off-switch, sensitivity range selection. Light sensitive switch EE202 2 more inputs for various automation devices controlling (time switch, presence detector, push button...). These products can be linked together to increase the number of levels and outputs controlled by one same cell. * Please check availability with your local Hager B&R sales office at time of ordering* description FUTURE RELEASE characteristics width in I cat. 17.5mm ref. 4 EE200* Two channels light sensitive switch the output is switched on/off according to the predefined lux level EE200* 230 V 50/60Hz 2 contacts NO 16 A 250 VAC AC1 - delivered without cell, can be associate with: - flush cell EE002 - or surface cell EE003 for each channel : - threshold setting - state indication LED - 4 positions selection switch : - On - Off - 2... 200 Lux - 200 ...20 000 Lux. EE200 delivered with surface cell EE003 4 EE201* Two channels light sensitive switch for cascading As well as EE200, it integrates 2 inputs for 2 operating modes. The selected mode always applies to the both outputs. EE202* same characteristics than EE200 above + additional automation. input E1 : 230 V, used to connect a contact like: switch, timer... operating mode selector : - mode 1 : automatic - mode 2 : half automatic, allows time delayed function (adjustable time: 1 min., 5 min., 10 min, 30 min., 45 min., 1 h 30, 2 h). delivered without cell, can be associated with : - flush cell EE002 - or surface cell EE003 EE202 delivered with surface cell EE003 FUTURE RELEASE 4 EE202* 4 EE203* Cell flush cell IP54 for EE100, 101, 110 & 170 surface cell IP54 for EE100, 101, 110 & 170 EE002 EE003 EE002 EE003 I.16 width in 1 : EH010, EH011 width in 2 : EH210, EH271 width in 3 : EH010,EH111, EH171 EH710, EH711, EH771 Analogue time switches selection chart Technical characteristics EH111 EH171 EH210 EH211 EH271 EH010 EH011 EH110 EH710 EH711 EH771 Width in z 17.5mm 3 230V 24 hrs. 15 min 200 hrs. auto/ on/off auto/ on/off auto/ on/off 200 hrs. 2 hrs. 30 min 7 days 24 hrs. 24 hrs. 30 min 200 hrs. auto/ on/off 230V 230V 230V 3 2 2 2 1 1 3 surface mounted (72mm x 72mm) 230V 7 days 3 hrs 30 200 hrs. auto/ on/off 230V 24 hrs. 20 min on/off 230V 24 hrs. 20 min 200 hrs. on/off 230V 7 days 2 hrs. 200 hrs. on/off Voltage 230V 230V 230V 24 hrs. 24 hrs. 24 hrs. 15 min 15 min 15 min Operating cycle Minimum switching Supply failure reserve Manual override - 200 hrs. - Subject to technical changes auto/ on auto/ on auto/ on/off I.17 Power interface Programming Energy distribution Connection Insulated busbars and connectors make it quick and easy to connect to devices mounted in loadcentres and panelboards. I.18 I.18 1 J.Insulated busbars and connectors J.1 Connection . description characteristics width in I 17.2 . RCD’s etc.fork type connection from side for cables : 25mm2 KF84A KM035 RCD neutral links 3 hole for fitting to RCD’s 35mm2 cable adaptor to suit Golf enclosures KM03A KM035 J.Insulated busbars and connectors description a range of connection devices to simplify installation of modular devices such as MCB’s... KDN180A insulated busbars fork type 1 phase 80A 1 phase 80A 56 KDN180B 1 phase 80A 18 KD180G 2 phase 80A 12 KDN280A 2 phase 80A 18 KD280G 3 phase 80A 12 KDN380A KB380A insulated busbars tongue type 3 phase 80A 18 KD380G 1 phase 80A 24 KB190C 2 phase 80A 12 KB280A 2 phase 80A 18 KB280G 3 phase 80A 12 KB380A KM03A insulating busbar ends cable connectors tongue type 3 phase 80A 18 KB380G KDN2XX/KDN3XX KZN023 connection from top of cables : 25mm2 connection from top of cables : 2 x 16 mm2 connection from side for cables : 25mm2 KF81A KF82A KF83A cable connectors .5mm 12 cat ref. employees and the public at large. www.look global. All Hager products products comply with the European RoHS and WEEE directives and environment management systems such as ISO 14001. Whenever Hager is active. we contribute to measures for ecological efficiency and environmental protection for a safe.eco-ficient ® energy saving solutions Energy Distribution Enclosure systems Wiring Accessories + Building Automation Cable management Saving energy .hagerbr.au/eco-ficient J. clean and healthy environment for consumers.3 .com. products and services we offer all help reduce energy and the consumption of natural resources. users of our products. act local The energy-saving systems. 13. order or contract then these conditions shall prevail except insofar as they are expressly varied by the Company in writing. taxes or government charges. any document forming part of any enquiry. No agent or representative has the authority to waive or alter these terms and conditions. or implied by. TAX The prices quoted do not include sales or goods and services tax unless specifically stated. PRICES (a) All prices are subject to change without notice and orders are accepted by the Company on the condition that they will be invoiced at the prices ruling at the date of despatch. whichever is the later date. We reserve the right to cancel any sale where goods offered ex stock have been previously sold or otherwise committed. All prices are strictly net unless otherwise stated. 7.hager B&R . 6. at the Company’s option. Unless otherwise agreed by the Company in writing. GENERAL These conditions of sale apply to any sale of items or equipment of the Company or. ACCEPTANCE A quotation is not to be construed as an offer or obligation to sell and the Company reserves the right to accept or reject any orders received. CANCELLATION OR VARIATION An order may. 9. (b) The purchaser must also pay for goods and services tax. If any condition is contrary to or excluded by law these conditions shall be modified but only to the extent of excluding that part of the conditions affected. FREIGHT (a) Unless otherwise stated prices include delivery to purchaser’s stores within the metropolitan areas of Australian capital cities or major centres by normal surface means. If on acceptance of a quotation the delivery date required exceeds a period of sixty (60) clear days then the company may amend the quotation. Quoted delivery dates are subject to confirmation when placing the order. (d) Freight cost on return of any goods which are not in accordance with Purchaser’s order will only be paid by the Company if returned by the Company’s nominated transport. 2. If the Purchaser considers that the products are not in accordance with the contract written notice must be given to the Company within seven (7) clear days and if no notice is received by the Company within that time the products are deemed to be in all respects in accordance with the contract. (c) Goods dispatched to other destinations are sold on a Free on Transport (FOT) basis.00. No variation or cancellation of any of these Conditions of Sale shall be binding on the Company unless agreed by a responsible officer of the Company in writing. whether voluntarily or otherwise or of a mortgagee entering into possession of any assets of the Purchaser.00 or any amount less than $20. 4. 8. Furthermore in the event of alterations to design or specifications all quotations given are subject to withdrawal or variation at any time prior to acceptance. and other duties. An order may be varied only if such variation is accepted by the Company in writing.50 will be applied to all invoices with a value of $20. they shall form part of that quotation. where a quotation is made. SURCHARGE A surcharge of $2. VALIDITY Unless otherwise stated quotations are open for acceptance for a period of 30 days from the date of quotation and thereafter are subject to confirmation before acceptance. . (b) Every endeavour will be made to give 30 days notice of any increase. 12. 5. (c) All prices shown in published catalogues or price lists are recommended selling prices only & there is no obligation on the part of any reseller to maintain such prices. specification. Non-Standard products will not be credited. be terminated in the event of insolvency of the Purchaser or of execution being levied against any of the goods of the Purchaser or of the Purchaser being placed in liquidation. PRECEDENCE In the event of conflict between these conditions and those which may be included in. INSPECTION The Purchaser shall inspect the products delivered on their arrival. and packing suitable for such transport for orders of value of $250 or more. 10. All goods approved for return shall be returned freight pre-paid and subject to a 15% restocking charge.terms and conditions of sale ACN 061 639 576 ABN 84 061 639 576 1. (b) For orders less than $250 the purchaser shall nominate the preferred freight method and be responsible for all freight charges. 14. Where the purchaser requires freight to be prepaid all expenses will be to his account at cost. the Company shall not in any event be liable to the Purchaser for any delay in the delivery or any non-delivery of the goods or any part of them. 11. DELIVERY The delivery period quoted commences from the date the Company receives sufficient information to proceed with supply or from the date the Company receives the Purchaser’s written order. CREDITS Goods will not be accepted for credit without prior approval of personnel at the Company’s nearest Sales Office. 3. TERMS OF PAYMENTS (a) The purchaser has to pay for goods within 30 days of purchase. PURCHASER’S SPECIFICATIONS The Company shall not be deemed to have agreed to comply with any specifications and drawings referred to in any order unless such specifications and drawings have been produced to the Company prior to the delivery of goods and are signed by the Company. Unless confirmed in writing by the Company any verbal agreement to vary undertakings assurances or understandings relevant to this quotation shall not be binding. A variation or cancellation by the Purchaser is subject to agreement by the Company and in any event is subject to the Company being indemnified by the Purchaser against any loss or damage. (d) A quotation includes only such goods as are specified therein. the Company undertakes that it will. if requested in writing by the Purchaser. or loss of profit. PACKING Unless stated otherwise in the quotation the price quoted includes packing in accordance with the Company’s standard practice.failure attributable to fortuitous circumstances or “force majeure”. The fulfilment of this undertaking shall constitute the Company’s sole liability in respect of any faulty goods not of the manufacture of the Company or its principals. DEFAULT OF PURCHASER If the Purchaser defaults in the due observance or performance of any or all of his obligations under any contract arising out of this offer or being a company takes or shall have taken against it any action for the winding up of the Company or the placing of the Company under official management or receivership. and (d) The company may enter the purchaser’s premises and repossess the goods.defect arising from materials supplied by the Purchaser or from a design requested by the Purchaser . commissioning or testing of any goods then outstanding (b) retain any security given or money paid by the Purchaser or available through enforcement of guarantee or security bonds lodged and apply this against the loss and damages incurred by it in the performance of the contract (c) take such steps as it may deem necessary to mitigate the damage suffered including the putting to use. installation. 16. The guarantee consists of repairing. 17. Therefore the Company reserves the right to alter the design and/or specifications of any product or equipment without notice and without incurring liability. expense. . DAMAGE OR LOSS IN TRANSIT Where carriage is the responsibility of the Company. or to be supplied under the contract and in its possession (d) exercise its rights under condition 21. This warranty is in addition to any statutory warranty which a Purchaser cannot waive but all other warranties are waived by the Purchaser.terms and conditions of sale ACN 061 639 576 ABN 84 061 639 576 15. modifying or replacing the parts or units recognised as defective within the shortest time at the Company’s expense. 18. corrosive atmosphere. or improper use of the goods . TITLE TO GOODS Property in the goods does not pass to the purchaser until they. WARRANTY All goods which are the Company’s own are guaranteed against faulty workmanship. PRODUCT DESIGN The Company engages in a policy of continuous development and improvement of its products. or within such times as will enable that Company to comply with the carrier’s conditions of carriage affecting loss or damage in transit. the Company’s liability and that of its resellers is wholly limited to the original cost of the product sold. sale or disposal of any goods supplied. but exclusive of transport and/or travelling expense. except as may otherwise be provided for by law. after which all liability on the part of the Company ceases. damage or injury caused by lack of care. make all reasonable endeavours in assisting the Purchaser to obtain from the manufacturer the benefit of any guarantee or warranty which the manufacturer may have expressly given as to the quality or fitness for any purpose of the goods. 19. Subject to the above. or if a mortgagee of the Purchaser takes possession of any of the Purchaser’s assets or being an individual the Purchaser petitions for his bankruptcy or seeks to assign his estate for the benefit of his creditors then the Company without prejudice to any other rights or remedies open to it may:(a) determine the contract and or suspend manufacture or delivery. Any unauthorised repairs or alterations to the equipment shall invalidate this warranty. Until property passes to the purchaser:(a) The purchaser must store the goods so that they are clearly identified as the company’s goods (b) The purchaser holds the goods solely as Bailee for the company (c) The purchaser may resell the goods as long as the purchaser holds any money received in trust for the company. 21. direct or consequential. have been paid for in full. the Company will repair or may replace free of charge contract goods lost or damaged in transit to the contractual point of delivery provided written notice of such loss or damage is given to the Company within three days of delivery or expected delivery. inclusive of parts and labour. hiring out. RISK The goods shall be at the risk of the Purchaser from the time of their delivery to the Purchaser’s store (where carriage is the responsibility of the Company) or otherwise from the time of their delivery to the Purchaser or its carrier. insufficient inspection or maintenance. arising out of the use or installation of products supplied by the Company all of which are supplied at the sole risk of the user.hager B&R . damages. In the case of goods not of the manufacture of the Company or its principals. for a period of twenty-four (24) months from the date of despatch. materials or design. Any other packing requested by the Purchaser or deemed necessary by the Company will be charged in addition to the price quoted. The guarantee does not apply in the following cases: . 20.replacements or repairs resulting from normal wear of units and machinery. and all other goods supplied by the company to the purchaser. Neither the reseller nor the Company shall be liable for any injury. Hager B&R Pty Ltd ACN 061 639 576 Unit 14-17 Riverside Centre 148 James Ruse Drive Parramatta NSW 2150 Ph (02) 9762 0200 Fx (02) 9687 0022 www. Martin Pty Ltd 85 Elizabeth Street Launceston TAS 7250 Ph (03) 6331 5545 Fx (03) 6331 4256 .hagerbr.com.P.au State Offices New South Wales Hager B&R Pty Ltd Unit 14-17 Riverside Centre 148 James Ruse Drive Parramatta NSW 2150 Ph (02) 9762 0200 Fx (02) 9687 0011 New South Wales (Newcastle) Ross Joice Agencies Pty Ltd 109-111 Broadmeadow Road Broadmeadow NSW 2292 Ph (02) 4961 4433 Fx (02) 4961 2498 Victoria Hager B&R Pty Ltd 50-52 Sunmore Close Heatherton VIC 3202 Ph (03) 8588 8400 Fx (03) 8588 8401 Western Australia Hager B&R Pty Ltd 20 Millrose Drive Malaga WA 6090 Ph (08) 9248 9744 Fx (08) 9248 2033 Queensland (Brisbane) Hager B&R Pty Ltd Brisbane South Industrial Park 51 Stradbroke Street Heathwood QLD 4110 Ph (07) 3714 1111 Fx (07) 3714 1091 Queensland (Townsville) Hager B&R Pty Ltd 25 Dalrymple Road Garbutt QLD 4814 Ph (07) 4775 6255 Fx (07) 4779 6736 South Australia B&R Enclosures Pty Ltd 505 Grand Junction Road Wingfield SA 5013 Ph (08) 8243 1166 Fx (08) 8268 3675 Northern Territory Jewell Distributors Pty Ltd Cnr Hidden Valley & Beaton Roads Berrimah NT 0828 PO Box 39362 Winnellie NT 0821 Ph (08) 8947 0870 Fx (08) 8947 0764 Tasmania (Launceston) W.