Ecoflam Burners 2014 en

March 27, 2018 | Author: anonimpp | Category: Fuel Oil, Valve, Hvac, Water Heating, Pipe (Fluid Conveyance)


Comments



Description

BURNERS2014 A complete range of burners for all fuels MONOBLOCK 20 - 17000 kW DUOBLOCK 350 - 25000 kW LIGHT OIL BURNERS HEAVY OIL BURNERS GAS BURNERS GAS/LIGHT OIL BURNERS GAS/HEAVY OIL BURNERS DUOBLOCK BURNERS Customised solutions for all types of application www.ecoflam-burners.com INDEX COMPANY PROFILE BURNER APPLICATIONS 4 4 RANGE OF PRODUCTS Designation ECOFLAM range - modular delivery system 5 8 10 BURNER STRUCTURE Gas train composition - EN676 configurations and export Gas train - Kit - Accessories assembly to the burner Electronic version with Burner Management System TS range - Duoblock burners 12 14 15 16 16 LIGHT OIL BURNERS MAX MAIOR 18 19 21 HEAVY OIL BURNERS MAXFLAM OILFLAM Forced oil preparation ring 23 24 24 26 GAS BURNERS MAX GAS BLU 27 28 33 DUAL FUEL BURNERS (GAS/LIGHT OIL) MULTICALOR 41 43 DUAL FUEL BURNERS (GAS/HEAVY OIL) MULTIFLAM 48 49 GAS TRAIN - KITS - ACCESSORIES Gas train: MAX GAS Gas train and connection pipe: BLU - MULTICALOR - MULTIFLAM Kit and accessories for gas Kit and accessories for oil Diagnostic tool for Thermowatt control Load controller and probes Silencer 52 52 53 54 56 56 57 57 BURNER SELECTION FORM 58 www.ecoflam-burners.com 3 the competence of its technical team and the wide offer of customised solutions for heating and industry applications.com . since 2005 has been incorporated into the Burners Division of Ariston Thermo Group and today takes advantage of the group synergies and offers a full range of blown air pressure jet burners for all fuels in monoblock and duoblock version up to 25 MW.Italy) in accordance with ISO 9001:2008 and products are distributed worldwide thanks to its network of partners. Energy Saving and Safety. ECOFLAM burners ensure high efficiency and reliable operation combined with functional features that reduce installation time and maintenance.A. ECOFLAM was established in 1973 in Castelfranco Veneto. ECOFLAM Bruciatori S.p. near Venice in the North East of Italy.COMPANY PROFILE ECOFLAM Bruciatori S. BURNER APPLICATIONS 4 HEATING APPLICATIONS AGRICULTURE APPLICATIONS METAL INDUSTRY APPLICATIONS FOOD INDUSTRY APPLICATIONS ASPHALT PLANTS AND BUILDING INDUSTRY APPLICATIONS TEXTILE.ecoflam-burners. Ecology.A. Throughout the time ECOFLAM has continued to develop products with constant devotion and determination addressing: Technological Research. is a specialist in combustion technologies and a worldwide brand recognised for the reliability of its burners. Manufacturing is carried out in the factory of Resana (Treviso .p. GLASS AND CERAMIC INDUSTRY APPLICATIONS INCINERATORS APPLICATIONS AND WASTE INDUSTRY CHEMICAL AND PETROLCHEMICAL INDUSTRY APPLICATIONS MODERNISATION OF PLANTS AND OTHER APPLICATIONS WOOD AND SOLID FUEL APPLICATIONS www. 1 2417 MAIOR P 800.com 5 .1 682 OILFLAM 300.1 100 570 200 300 400 500 600 kW 464 930 OILFLAM 120.1 5800 2000 3000 4000 5000 7500 2750 MAIOR P 1000.1 1000 3000 MAIOR P 400.1 12500 5000 OILFLAM 1800.1 8500 3300 10500 MAIOR P 1200.1 1300 MAIOR P 500.1 15000 5700 0 2000 4000 6000 17000 8000 10000 12000 14000 16000 18000 20000 kW www.1 1780 710 2372 MAIOR P 300.1 8500 3300 OILFLAM 1200.1 1423 592 MAIOR P 200.1 12500 5000 15000 MAIOR P 1800.1 5000 1795 OILFLAM 700.RANGE OVERVIEW LIGHT OIL RANGE MAX 1 18 41 MAX 1 Low NOx 18 MAX 4 20 MAX 4 Low NOx 23 36 59 47 MAX 8 105 47 MAX 12 130 60 MAX 15 190 73 MAX 20 237 86 MAX 30 110 MAX P 12 319 130 60 MAX P 15 190 77 MAX P 25 102 300 MAX P 35 166 427 MAX P 45 202 0 100 MAIOR P 60 546 200 300 400 500 600 kW 415 710 MAIOR P 80 474 949 MAIOR P 120 830 MAIOR P 150.1 7500 2750 OILFLAM 1000.1 3900 1578 OILFLAM 600.1 10500 4367 OILFLAM 1500.1 5800 2417 OILFLAM 800.1 5000 1795 0 1000 MAIOR P 700.1 682 OILFLAM 170.1 682 1700 OILFLAM 200.1 1395 2093 1000 OILFLAM 400.1 3900 1578 MAIOR P 600.1 4367 MAIOR P 1500.ecoflam-burners.1 3000 1300 OILFLAM 500.1 5700 0 6000 kW 2000 4000 17000 6000 8000 10000 12000 14000 16000 18000 20000 kW HEAVY OIL RANGE MAXFLAM 10 68 136 MAXFLAM 20 108 227 MAXFLAM 30 170 340 MAXFLAM 30 AB 205 MAXFLAM 50 AB 410 205 0 OILFLAM 80. 1 200 342 BLU 2000.1 300 875 260 BLU 1200.1 low NOx 400 3000 875 BLU 5000.1 500 700 245 BLU 1000.1 2500 BLU 12000.1 10500 2700 13000 BLU 15000.1 600 kW 970 280 BLU 1200.1 8500 2500 MULTICALOR 1200.com 1000 3900 1200 MULTICALOR 800.1 800 3000 875 MULTICALOR 500.1 1500 BLU 7000.1 10500 2700 MULTICALOR 1500.1 15000 4000 0 www.1 13000 3690 MULTICALOR 1800.1 1500 1200 5000 5800 7500 2000 MULTICALOR 1000.1 MULTICALOR 600.1 600 2150 630 MULTICALOR 400.1 1300 400 1770 414 MULTICALOR 300.1 15000 4000 0 2000 17000 4000 6000 8000 10000 12000 14000 16000 18000 20000 kW 1400 1600 1800 2000 kW 18000 20000 kW DUAL FUEL (GAS/LIGHT OIL) RANGE MULTICALOR 45 AB 190 500 MULTICALOR 70 AB 250 MULTICALOR 70 PR-AB 700 190 700 MULTICALOR 100 AB 300 MULTICALOR 100 PR-AB 1000 200 1000 MULTICALOR 140 AB 400 MULTICALOR 140 PR 0 MULTICALOR 170.GAS RANGE MAX GAS 40 17 48 MAX GAS 70 34 70 MAX GAS 105 49 MAX GAS 120 49 MAX GAS 120 AB 108 120 40 120 MAX GAS 170 55 MAX GAS 250 55 170 240 MAX GAS 350 350 100 MAX GAS 500 500 120 0 100 BLU 700.1 600 800 1000 1200 1400 1600 1800 2000 kW 2150 630 BLU 4000.1 1550 400 1770 414 BLU 3000.1 low NOx 200 270 BLU 1000.ecoflam-burners.1 200 342 MULTICALOR 200.1 5800 7500 2000 8500 BLU 10000.1 3690 BLU 18000.1 low NOx 1100 300 0 BLU 1700.1 6 1300 250 2000 4000 17000 6000 8000 10000 12000 14000 16000 .1 1500 MULTICALOR 700.1 low NOx 1200 290 BLU 1500.1 1500 BLU 8000.1 3900 5000 1200 BLU 6000. 1 250 300 1550 0 1000 2000 3000 4000 5000 kW 0 1000 2000 3000 4000 5000 kW 0 1000 2000 3000 4000 5000 kW 0 3000 6000 9000 12000 15000 kW 0 3000 6000 9000 12000 15000 kW 0 5000 10000 15000 20000 25000 kW 0 5000 10000 15000 20000 25000 kW PLATFORM 280 Min VSD Min kW Max kW Oil 200.1 1600 2700 13100 PLATFORM 710 Min VSD Min kW Max kW Oil 1800.1 15000 4000 0 2000 17000 4000 6000 8000 10000 12000 14000 16000 18000 20000 kW DUOBLOCK RANGE Note: "Oil"/"Gas" indicates the output range for light oil.1 5000 7000 25000 Gas 25000.1 3200 6000 25000 www.1 5800 7500 2000 MULTIFLAM 1000. heavy oil.DUAL FUEL (GAS/HEAVY OIL) RANGE MULTIFLAM 200.1 3000 875 MULTIFLAM 500.1 1500 MULTIFLAM 800.1 13000 3690 MULTIFLAM 1800. gas and dual fuel burners.1 1500 MULTIFLAM 700.ecoflam-burners.1 414 MULTIFLAM 300. PLATFORM 260 Min VSD Min kW Max kW Oil 120 300 450 1400 Gas 1500.1 700 875 3900 Gas 4000.1 725 1500 5800 PLATFORM 630 Min VSD Min kW Max kW Oil 800.1 10500 2700 MULTIFLAM 1500.1 1600 2000 8500 Gas 8000.1 2150 630 MULTIFLAM 400.1 1050 1500 5800 Gas 6000.1 3200 5700 17000 Gas 18000.1 500 710 2372 Gas 2000.1 1050 2000 8500 Oil 1200.1 500 875 3900 PLATFORM 380 Min VSD Min kW Max kW Oil 600.1 8500 2500 MULTIFLAM 1200.com 7 .1 2100 4000 17000 PLATFORM 800 Min VSD Min kW Max kW Oil 2500.1 3900 1200 5000 MULTIFLAM 600.1 350 414 2150 PLATFORM 320 Min VSD Min kW Max kW Oil 400.1 2400 2700 13100 Gas 12000. Gas EN676 (<80 mg/kWh) Standard Class 2 .1 4 kg/h 120 kg/h 40 kW 1200 kW 300 kg/h .com CONFIGURATION / ADDITIONAL INFO HT D SGT NS High temperature D pump version for light oil (max visc.BURNER DESIGNATION BLU 1200.Gas EN676 (<120 mg/kWh) Low NOx Class 3 yellow flame (<120 mg/kWh) Standard Class 2 . LMV.Oil EN267 (<250 mg/kWh) OPERATION TYPE R P PAB P 120 AB P 120 AB HS Z3 / S3 PR PR-PAB MD E 1 stage 1 stage with pre-heater 1 stage . oil: kg/h) MAX 4 MAIOR 120 MAX GAS 40 BLU 1200. 50°E at 50°C) RANGE NAME + TS Duoblock burner MODEL SIZE (gas: kW.LPG Light oil Light oil Heavy oil (max visc. 50 Hz 110 V./LAL... 50-60 Hz 230/400 V.1 LN PAB TL SGT 230-50 TW RANGE NAME BY FUEL TYPE MAX GAS BLU MAX MAIOR MAXFLAM OILFLAM MULTICALOR MULTIFLAM Gas natural ....ecoflam-burners.Oil EN267 (<185 mg/kWh) Standard Class 1 ... ETO BT3 8 Thermowatt Siemens Siemens electronic Lamtec Etamatic OEM Lamtec BT300 www. 50-60 Hz ELECTRICAL EQUIPMENT (CONTROL BOX) TW LFL.soft start 2 stages light/heavy oil 120 kg/h . 50°E at 50°C) Heavy oil (max visc. 5°E at 20°C) Separate gas train Without silencer ./LGK.LPG Gas natural .1 MULTICALOR 300. 50°E at 50°C) Dual fuel: gas/light oil Dual fuel: gas/heavy oil (max visc.Low NOx MAX Low NOx MAX MAIOR Low NOx Class 3 .soft start 2 stages oil hydraulic system 120 kg/h .soft start 2 stages with 3 nozzles / 3 stages with 3 nozzles 2 stages progressive mechanical 2 stages progressive mechanical gas / 2 stages oil 2 stages modulating mechanical with PID 2 stages modulating electronic HEAD TYPE TC TL Short head Long head FUEL LPG BIOGAS KER B10 Gas / Light oil / Heavy oil Liquid gas Biogas Kerosene Biodiesel ELECTRICAL POWER SUPPLY 230-50 230-50-60 230-400-50 110-50-60 230 V. 50 Hz 230 V.soft start 2 stages gas .3000 kW EMISSIONS LN .. 2" Threaded connection DN40 Flanged connection DN50 Flanged connection DN60 Flanged connection DN80 Flanged connection DN100 Flanged connection DN125 Flanged connection GAS TRAIN MATCHING BURNER MAXGAS40-120 BLU/MULTI MAXGAS40-120SX Model matching MAX GAS 40-120 Model matching BLU-MULTICALOR-MULTIFLAM range Left side connection for MAX GAS 40-120 KIT AND ACCESSORIES DESIGNATION KITTC-VPS504VCS Kit tightness control VPS504 for VCS gas valve PROBE-WATER130C Water probe up to 0÷130° С GTCP-DN80-260/280/320 OPT / STD / ACS Connection pipe for gas train DN80 platform 260/280/320 Optional / Standard / Accessory www.ecoflam-burners. 3/4" Threaded connection Rp.DN80 . 1/2" Threaded connection Rp.VGD40 . 1"1/4 Threaded connection Rp.S2 . 1"1/2 Threaded connection Rp.com 9 . 1" Threaded connection Rp.Landis Honeywell Brahma OPERATION TYPE 1 2 3 4 5 1 stage or 2 stages with butterfly valve 2 stages solenoid valve 2 stages pneumatic 2 stages electronic 2 stages mechanical MODEL TYPE MBC120 MBDLE403 MBZRDLE410 VGD20503 VCS240 EG12L MultiBloc model MBC120 MultiBloc model MBDLE403 MultiBloc 2 stages valve model MBZRDLE410 Siemens Landis model VGD20503 Kromschröder model VCS240 Brahma model EG12L VALVE NOMINAL DIAMETER RP15 RP20 RP25 RP32 RP40 RP50 DN40 DN50 DN60 DN80 DN100 DN125 Rp.BLU/MULTI GAS TRAIN VALVE MANUFACTURER D K S H B Dungs Kromschröder Siemens .GAS TRAIN DESIGNATION GT . For burners over 1700 kW gas train connection pipe must be ordered. Kits and accessories are delivered separately. that shall complete the gas train or the burner according to the applicable standard.ECOFLAM RANGE ECOFLAM burners have been designed and built in compliance with all current regulations and directives. burner body including combustion head and separate gas train with separate additional kits and accessories.KITS .ecoflam-burners. All burners comply to the safety and energy saving operation regulations within the standard of their respective performance range. Configurated and special versions on request with burner selection form. Kits and accessories are managed and delivered separately. All gas burners are delivered in separate set/box. All dual fuel burners are delivered in separate set/box. burner body including combustion head and separate gas train with separate additional kits and accessories. ISO9001:2008 COMPONENT TYPE CB BBCH BB CH GTCP GT SV Complete Burner (for light oil or heavy oil) Burner Body with Combustion Head (without gas train) Burner Body Combustion Head Gas Train Connection Pipe Gas Train (delivered separately) Separate Ventilator for duoblock burner GAS BURNERS AND DUAL FUEL BURNERS ECOFLAM gas and dual fuel burners are delivered in compliance with the applicable standards.GTCP . Export configuration gas train completion are available but it is mandatory for the local installer in this case to comply to the local safety regulations. Kits and accessories are delivered separately. Gas train is delivered separately with different configurations. that shall complete the gas train or the burner according to the applicable standard. The quality is guaranteed by a quality and management system certified in accordance with ISO 9001:2008. Kits and accessories shall be included in the gas train and in the burner as described in the scope of supply in accordance with the instructions and the local safety regulations and codes of practise. i. 10 www.ACCESSORIES All gas and dual fuel burners gas trains are delivered separately in different models and configurations.com . i. GAS TRAIN .e.e. including filter and flexible hoses up to 6 MW.com 11 . Installation.LIGHT OIL AND HEAVY OIL BURNERS ECOFLAM oil burners are delivered in compliance with the applicable standards. Additional accessories and options shall be installed by the installer in accordance with the instruction and the local safety regulations and codes of practise. providing a customised and more cost effective solution. including filter and flexible hoses up to 6 MW. All light oil burners are delivered complete in one single package. All heavy oil burners are delivered with electrical pre-heater preassembled into the burner body. DUOBLOCK BURNERS ECOFLAM offers selected models/outputs in duoblock version for all the fuels that can be delivered based on the configuration requested (mechanical or electronic) by the customer in order to better fit into the application. start-up and maintenance must be carried out by authorised specialists and all applicable guidelines and regulations (including local safety regulations and codes of practise) must be observed. BURNER SELECTION: the selection of the type of operation and configuration must be done by professional personnel. Configurated and special versions on request with burner selection form. in order ! to grant the correct working of the burner. www.ecoflam-burners. .ecoflam-burners.com .MULTICALOR 300.1 MULTIFLAM 300.1 change spring and damping Kromschröder VCS Double solenoid valve VCS Kromschröder and minimum pressure switch + ACS gas governor & filter Export configuration Export completion gas train depending on the models shall be completed in compliance with local safety regulations.GT .1 ..BURNER STRUCTURE BURNER COMPOSITION .ACS are delivered in separate boxes SV and additional KIT-ACS to be ordered and delivered separately Electronic version with BMS BBCH . operating pressure range up to 500 mbar FS1B up to 1 bar GAS GOVERNOR & FILTER SPRING FGDR FGDR: default spring is neutral for outlet pressure range 10-30 mbar For different outlet setting range please change the spring according to our technical documentation FILTER Gas filter to complete VGD gas trains.SCOPE OF SUPPLY FOR ALL BURNERS INCLUDES THE FOLLOWING PARTS: BBCH BURNER BODY with COMBUSTION HEAD GTCP GAS TRAIN CONNECTING PIPE GT GAS TRAIN SEPARATE * Export configuration EN676 completion * Minimum working pressure = Pressure drop inlcudes “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676 Light oil Heavy oil BBCH is delivered in one single box Additional KIT-ACS to be ordered and delivered separately Gas Dual fuel BBCH .GT .22 mbar WARNING: from BLU 3000. regulator and minimum pressure switch Siemens VGD Double gas valve with actuators and regulator VGD Siemens and minimum pressure switch + ACS gas filter Default blank spring: head pressure 0.GT .ACS are delivered in separate boxes Available from 2 MW with loosen electrical panel or separate electrical or switch cabinet Gas train size vs Diameter of the connection To be included from the platform 280 (≈1700 kW) MultiBloc MB Gas MultiBloc Dungs: compact double solenoid valve with integrated filter.ACS are delivered in separate boxes Additional KIT-ACS to be ordered and delivered separately Duoblock BBCH . operating pressure up to 1 bar (suggested as additional for all installations) GAS FILTER 12 www. FGDR / FS1B WARNING: size and fitting depend on the burner and the gas train selected Gas pressure governor and filter model FGDR. Adaptor for gas train connection MAX GAS range for LPG KITPOT-. Potentiometer ACS Antivibration coupling ACS Ball valve ACS Manometer + Push button ACS ACS Magnetic + Selfcleaning oil filter KITS Other kits: see related pages ACCESSORIES Other ACS: see related pages FLEXSHOP Configurations .... ACCESSORIES AND CONFIGURATIONS: DIAGNOSTIC TOOL KITDT-TW Diagnostic tool for Thermowatt control box TIGHTNESS CONTROL KITTC-.ACS Additional kits and accessories to be installed in order to comply with the local safety regulations For full modulating version: BURNER BODY PR + PID REGULATOR and PROBE PID CONTROLLER KITMD-.KIT. Silencer is complementary and can be ordered as a separate KIT Kit available starting from platform 260 KITLPG-.... depending on fuel. KITxx-.. KITMD-RWF50 Modulation of burner can be done also from the PID of the boiler panel MATCHING PROBE PROBE-...com 13 .. air.. Gas leakage control device for gas trains Available in different models depending on the type of the gas train Compulsory for EN676 over 1200 kW – 1032000 kcal/h MAXIMUM GAS PRESSURE SWITCH KITPRES. Matching probe for hot water...ecoflam-burners.Service Configurations can be implemented in the factory from our internal FLEXSHOP Swirl system Swirls for blast tube that can reduce flame lenght up to 10-50%. LPG transformation kit for gas burner (see related models and technical documentation for operating gas pressure) KITADAPT-. backpressure and shape of combustion chamber Available for different fuel burner head KITCV Continuous Ventilation Available for different burner Kit for burner with Thermowatt control box Other Special configurations will be evaluated on request AFTER SALE SERVICE CONTRACTS ECOFLAM Service Department can offer start up service contracts SPARE PARTS ECOFLAM original spare parts www.. Maximum gas pressure switch To be installed in order to comply with the local safety regulations ADDITIONAL KITS ACCESSORIES KIT .... steam Additional kits and accessories KITSIL-.. 1 .. • kit and accessories shall be fitted by the installer in accordance with the instructions and the local safety regulations and codes of practise.40.100 . Gas leakage control 5 3 6 8 KIT .MULTIFLAM 300.125 3.MB-DLE 412 . in order to fit the gas train. Antivibrating coupling ACS 4.22 mbar.065 .. Tightness control device (VPS-VDK-LDU) must be included over 1200 kW according to EN676.Gas train connection pipe GTCP ** Default blank spring: head pressure 0. Antivibrating coupling ACS 5. Minimum gas pressure switch 7 6 6.com EN676 VCS KROMSCHRÖDER EN676 2 KITTC * Export 1 GAS TRAIN EN676 1. MB-DLE 407 . Gas filter ACS KIT ...40.VCS 350 R/LW Rp 2” 2..GAS TRAIN COMPOSITION .EN676 CONFIGURATION AND EXPORT ECOFLAM gas trains are delivered separately for all gas and dual fuel burners and are available in different configurations and models: • EN676 standard gas train + kit/accessories in compliance with EN676.1 change spring and damping * EN676 CONFIGURATION: for VCS gas trains gas governor and filter must be included. Ball valve ACS VGD 20.. Main gas pipe VGD SIEMENS 2. Gas governor & filter 5.Gas train connection pipe GTCP ** 1. Gas governor and filter included EN676 Compact double solenoid valve with integrated filter.1.Gas train connection pipe GTCP ** 1. regulator and minimum pressure switch 8.40.1 . Gas leakage control 1 2 3 4 5 6 8 7 GAS TRAIN KITTC * KIT .1 .MB-DLE 420 7 2. Main gas pipe MULTIBLOC DUNGS . ! Backpressure of boiler/application must be added/included in order to have the total minimum pressure drop. Minimum gas pressure switch 6. for VGD filter must be included. Actuator 7. Actuator 8. the corresponding ! connection pipe must be ordered (GTCP size and fitting depend on the burner and the gas train selected).Maximum gas pressure switch KITPRES ACS .ecoflam-burners.080 .MB-DLE 415 . Working gas valve ACS 8. Main gas pipe Double solenoid valves and minimum pressure switch + ACS gas governor and filter VCS 125 R/LW Rp 1” .Maximum gas pressure switch KITPRES ACS .1 .MULTICALOR 170. Working gas valve + 11. Ball valve ACS 3.MULTIFLAM 300. Minimum gas pressure switch 6. 14 www. Safety + Working gas valve 7. Antivibrating coupling ACS 5. Safety gas valve 7. Yellow spring: head pressure 15.MB-DLE 410 . Gas leakage control 2 3 9 5 8 11 10 Export Double gas valves with actuators and regulator and minimum pressure switch + ACS gas filter 1 GAS TRAIN KITTC * 9.503 Rp 2” / VGD 40. ! KITTC-.MULTICALOR 300.120 mbar From BLU 3000.VCS 240 R/LW Rp 1”1/2 . • Export configuration + others additional options to be added by installer in compliance with local safety regulations and codes of practise. Ball valve ACS 3. PRESSURE DROP includes: “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676. Safety gas valve + 10. ** WARNING: from BLU 1700.Maximum gas pressure switch KITPRES ACS . MULTICALOR 170.Model Compulsory over 1200 kW MODULATION KIT LPG TRANSFORMATION KITMD-RWF50 PROBE-. right hand side layout (or left with kit) * WARNING: from BLU 1700.1 .1: ! in order to fit the gas train the corresponding connection pipe must be ordered KIT AND ACCESSORIES GAS GOVERNOR/FILTER MAX GAS PRESSURE SWITCH FGDR .1 ÷ 18000.FILTER KITPRES50 KITPRES150 Compulsory EN676 TIGHTNESS CONTROL KITTC..com 15 .1 MULTIFLAM 300.. Additional ! accessories and kits shall be installed by the installer in accordance with the local safety regulations and codes of practise.1 .1 ÷ 1800. right hand side layout (or left with kit) MAX GAS 350 ÷ 500 BLU 700..ACCESSORIES ASSEMBLY TO THE BURNER HOW TO INSTALL THE GAS TRAIN INTO THE BURNER AND CALCULATE THE OVERALL DIMENSIONS MAX GAS 40 ÷ 250 Gas train with connection on the top BLU 1700.MULTIFLAM 300..1 ÷ 1500.ecoflam-burners. KITLPG-MAXGAS..KIT .1 Gas train with connection at the bottom.GAS TRAIN .1 ÷ 1800.1 MULTICALOR 170. www. KITLPG-BLU..1 MULTICALOR 45 ÷ 140 Gas train with right hand side connection DUOBLOCK Gas train with connection at the bottom. WARNING: EN676 compulsory kit and accessories must be ordered to comply with the safety regulations. 1 800 22 ÷ 25 MW www.1 MULTICALOR 400.1 OILFLAM 800. i.1 MULTIFLAM 800.1 MULTIFLAM 1200.1 MULTICALOR 200.1 630 7 ÷ 9 MW MAIOR 800.1 BLU 2000.1 MULTIFLAM 200.1 BLU 6000.com Feasibility only on request .5 MW 280 16 1.1 630 10 ÷ 13 MW MAIOR 1200.1 MULTIFLAM 1800.1 710 15 ÷ 18 MW MAIOR 1800.1 MULTICALOR 1800.e. • Heavy oil and dual fuel (gas/heavy oil) are delivered with pre-heater assembled into the burner body or on request in a separate frame/skid.1 OILFLAM 600. • GT: gas train.1 Gas BLU 1500.1 MULTIFLAM 600.1 OILFLAM 1200.1 MULTIFLAM 400.1 MULTICALOR 800.1 OILFLAM 400. BUS multi Pmin GAS PLT GAS TS RANGE .1 MULTICALOR 1200.1 MULTICALOR 600.: CAN-Bus • BBCH: burner body with combustion head.1 320 3 ÷ 4 MW MAIOR 400.5 ÷ 2 MW Light oil MAIOR 120 Heavy oil OILFLAM 120.1 BLU 12000.1 380 5 ÷ 6 MW MAIOR 600. • SV: separate ventilator for Duoblock version.8 ÷ 1.1 OILFLAM 200.ecoflam-burners. T P Pmax OIL Pmin OIL M PAIR For all burners the delivery scope is in a modular system. Platform Max output range 260 0.1 BLU 4000. • KIT-ACS: kits and accessories to complete the burner in order to comply with the local safety regulations and codes of practise.1 Gas/Light oil MULTICALOR 140 Gas/Heavy oil - MAIOR 200.ELECTRONIC VERSION WITH BURNER MANAGEMENT SYSTEM ECOFLAM offers the electronic range with BMS from 2 MW up to 17 MW in Monoblock and up to 25 MW in Duoblock configuration with electrical panel assembled into the burner or on request with separate switch cabinet.DUOBLOCK BURNERS SELECTED OUTPUT TO MATCH MAIN BOILERS AND INDUSTRIAL APPLICATION Available models for different fuels in standard progressive mechanical configuration with derivative electrical panel. Electronic version with Burner Management System with separate switch cabinet on request.1 OILFLAM 1800.1 BLU 18000.1 BLU 8000. MONOBLOCK - DUOBLOCK RANGE WITH BMS Electronic compound manager for burner has been introduced into ECOFLAM range in order to improve performance and efficiency of modern firing installation. BMS is a compact powerful solution suitable for the control and supervision of single or dual fuel forced draft burners. This system is designed to match an extensive range of components such as flame, temperature and pressure sensors, gas valves, variable speed fan motors and oxygen control that can be managed from different bus interfaces. BMS solutions are meant to bring the main following benefits: • • • • • • • significant energy saving in both fuel and electricity; optimize process performance and minimize costs; simple commissioning and operating in total safety; integrated solution with a wide range of communication interfaces; combustion optimization with O2/CO control; effective diagnostic and real time status information; user interface easy to use and program. Communication interface Temperature Pressure sensors Flame sensors Leakage System Display Actuators INVERTER SYSTEM VSD module is an extension to the BMS and is used for the control of a variable speed drive, that allows electrical comsumption savings, lower noise emissions, gradual fan starting and reduction of mechanical stress. O2 Trim O2-CO TRIM CONTROL O2-CO control allows the control of the residual oxygen content in order to increase the boiler efficiency. CO Trim VSD Inverter MONITORING APPLICATION Reliable and safe flame detection system for single and multiple burner furnaces. RANGE OF OUTPUT WITH BURNER MANAGEMENT SYSTEM Turndown ratio standard with inverter oil side VSD inverter MAIOR 200.1-1800.1 1÷5 1÷5 1÷5 Kit Kit OILFLAM 200.1-1800.1 1÷5 1÷5 1÷5 Kit Kit BLU 2000.1-18000.1 1÷6 1÷8 1÷5 Kit Kit MULTICALOR 200.1-1800.1 1÷6 1÷8 1÷5 Kit Kit MULTIFLAM 200.1-1800.1 1÷6 1÷8 1÷5 Kit Kit DUOBLOCK 1÷6 1÷8 1÷5 Kit Kit Model O2-CO trim Additional functions Flame monitoring sensors Communication interfaces Display interface www.ecoflam-burners.com 17 18 www.ecoflam-burners.com All light oil burners are delivered complete in one single package including filter and flexible hoses up to 6 MW. DUOBLOCK and ELECTRONIC versions are available on request for selected output to match main boilers and industry application. MAIOR models over 7 MW are available on request based on the configuration requested (mechanical or electronic) in order to better fit into the application and provide a customised and more cost effective solution. MAIOR range for light oil are available in two stages with hydraulic system or servomotor up to 350 kg/h and from the model MAIOR 45 in progressive operation that can be turned in modulating with a PID regulator. MAIOR - Max visc. 1,5°E at 20°C The range is available in standard class 2 and Low NOx emission class 3 (yellow flame) according to EN267. The range fits standard heating and light industry applications. MAX range for light oil combines a high efficiency fan ventilation system (HPV) with features ranging from easy matching on boilers up to easy maintenance and set-up. MAX - Max visc. 1,5°E at 20°C LIGHT OIL BURNERS instruction manual for adjustments and modifications. All burners 230-400V/50Hz are factory tested at 400V/50Hz ! three-phase. If main supply is three-phase 230V/50Hz see • CV: Continuous ventilation version • HT: High temperature version • D pump: light oil with max viscosity 5°E at 20°C • OEM and special application version only on request AVAILABLE CONFIGURATIONS ON REQUEST • KIT Biodiesel • KIT Wieland plugs • Light oil pump unit on request • PID modulating KIT and probe • Diagnostic tool for TW control box • Silencer (starting from platform 260) KIT - ACS (see dedicated pages) www.ecoflam-burners.com 19 47 60 73,4 86,4 110 MAX 8 TW - 1/230V/50-60Hz MAX 12 TW - 1/230V/50-60Hz MAX 15 TW - 1/230V/50Hz MAX 20 TW - 1/230V/50Hz MAX 30 TW - 1/230V/50Hz 166 202 MAX P 35 AB TW - 1/230V/50Hz MAX P 45 AB TW - 3/230-400V/50Hz MODEL MIN 20 MAX 4 R TW - 1/230V/50-60Hz Two stages class 2 (NOx <185 mg/kWh) - B10 20 MAX 1 R TW - 1/230V/50-60Hz MODEL MIN 20 MAX 4 TW - 1/230V/50-60Hz One stage with pre-heater versions (NOx <185 mg/kWh) - B10 17,6 MIN 17,6 22,5 MIN MAX 1 TW - 1/230V/50-60Hz MODEL One stage class 2 (NOx <185 mg/kWh) - B10 MAX 1 Low NOx TW - 1/230V/50-60Hz MAX 4 Low NOx TW - 1/230V/50-60Hz MODEL One stage Low NOx class 3 (NOx <120 mg/kWh) - B10 LIGHT OIL BURNERS MAX OUTPUT [kW] OUTPUT [kW] OUTPUT [kW] OUTPUT [kW] 546 427 MAX 59 39 MAX 319 237 190 130 105 59 41,4 MAX 35,5 47,4 MAX 17 14 MIN 1,7 1,5 MIN 9,3 7,3 6,2 5,1 4 1,7 1,5 MIN 1,5 1,9 MIN FLOW RATE [kg/h] FLOW RATE [kg/h] FLOW RATE [kg/h] FLOW RATE [kg/h] 46 36 MAX 5 3,5 MAX 27 20 16 11 8,9 5 3,5 MAX 3 4 MAX CODE 3140420 3140421 3140933 3141314 TC TL TC TL 3142711 3142712 3142720 3142721 TC TL TC TL BLAST TUBE CODE 3142709 3142710 3142714 3142715 3142716 3142717 3142718 3142719 3142729 3142730 3142731 3142732 3142733 3142734 TC TL TC TL TC TL TC TL TC TL TC TL TC TL BLAST TUBE CODE 3142713 3142722 CODE BLAST TUBE TC TC BLAST TUBE 3 6.1/230V/50Hz MAX P 35 AB HS TW .1 MIN FLOW RATE [kg/h] FLOW RATE [kg/h] 46 36 27 20 16 11 8.7 MIN 17 14 8.1/230V/50-60Hz MODEL MIN 77 MAX P 15 AB HS .ACCESSORIES see accessories page B10: oil pump for biodiesel.B10 60 MIN MAX P 12 AB HS .1/230V/50Hz MAX 20 D HT TW .ecoflam-burners.1/230V/50Hz One stage class 2 (NOx <185 mg/kWh) .4 86.2 5.5 5.1/230V/50Hz MAX P 45 AB HS D HT TW .1/230V/50Hz MAX P 35 AB HS D HT TW .1/230V/50-60Hz MODEL Two stages hydraulic system class 2 (NOx <185 mg/kWh) LIGHT OIL BURNERS MAX 546 427 319 237 190 130 105 59 MAX 546 427 300 190 130 MAX 17 14 9.20 www.3/230-400V/50Hz OUTPUT [kW] OUTPUT [kW] DESCRIPTION Diagnostic tool for TW control box KIT .4 16 11 MAX CODE 3142724 3142723 3142726 3142725 3142728 3142727 3142735 3142736 3142737 3142738 3142739 3142740 on request on request on request on request TC TL TC TL TC TL TC TL TC TL TC TL TC TL TC TL 3124094 3124095 3122708 3122709 3122710 3122274 3140409 3140412 3140418 3140419 TC TL TC TL TC TL TC TL TC TL BLAST TUBE CODE BLAST TUBE .1/230V/50Hz MAX 30 D HT TW .4 110 166 202 MAX 8 HT TW .com 102 166 202 MAX P 25 AB HS .1/230V/50-60Hz MAX 15 HT TW .6 6.3/230-400V/50Hz 47 60 73. HT: high temperature 20 MAX 4 HT TW .3 7. D pump: max viscosity 5°E at 20°C.1 4 1.9 5 MAX 46 36 25.1/230V/50Hz MAX P 45 AB HS TW .1/230V/50-60Hz MAX 12 HT TW . 3/230-400V/50Hz MODEL 415 MAIOR P 60 AB HS D .ecoflam-burners.3/400V/50Hz MAIOR P 400.3/230-400V/50Hz MAIOR P 300.www.3/230-400V/50Hz MIN 474 MAIOR P 80 AB HS .1 AB Z3 .1 AB HS .3/230-400V/50Hz MAIOR P 150.com 21 830 592 710 1000 1300 MAIOR P 120 AB HS .3/230-400V/50Hz MAIOR P 300.3/230-400V/50Hz MAIOR P 200.3/230-400V/50Hz 415 MAIOR P 60 AB .1 AB HS Z3 .3/230-400V/50Hz MAIOR P 150.3/230-400V/50Hz MODEL Two stages hydraulic system LIGHT OIL BURNERS MAIOR OUTPUT [kW] OUTPUT [kW] 3900 3000 2372 1780 1423 949 710 MAX 3900 3000 2372 1780 1423 949 710 710 MAX 110 85 60 50 70 40 35 MIN 110 85 60 50 70 40 35 35 MIN FLOW RATE [kg/h] FLOW RATE [kg/h] 350 250 200 150 120 80 60 MAX 350 250 200 150 120 80 60 60 MAX OPT OPT OPT OPT OPT OPT OPT SILENCER OPT OPT OPT OPT OPT OPT OPT OPT SILENCER CODE 3121016 3122265 3121018 3122266 3121020 3122269 3121022 3121021 3121024 3121023 3143731 3143742 3143733 3143732 TC TL TC TL TC TL TC TL TC TL TC TL TC TL 3140151 3140152 3141572 3141571 3121063 3121064 3121065 3121066 3121067 3121068 3121069 3121070 3143743 3143744 3143745 3143746 TC TL TC TL TC TL TC TL TC TL TC TL TC TL TC TL BLAST TUBE CODE BLAST TUBE .3/400V/50Hz 710 1000 1300 MAIOR P 200.1 AB HS .3/230-400V/50Hz Two stages 415 MIN MAIOR P 60 AB HS .1 AB .3/400V/50Hz MAIOR P 400.1 AB .1 AB .3/400V/50Hz 830 MAIOR P 120 AB .1 AB HS .3/230-400V/50Hz 592 474 MAIOR P 80 AB . 3/400V/50Hz MAIOR P 1200.3/400V/50Hz MAIOR P 1000.3/400V/50Hz see accessories page see accessories page see accessories page see accessories page see accessories page 1000 MAIOR P 300.1 PR .3/400V/50Hz MAIOR P 800.1 PR .3/230-400V/50Hz MAIOR P 150.DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.1 PR .3/400V/50Hz MAIOR P 700.1 PR .3/400V/50Hz MAIOR P 1500.3/400V/50Hz MAIOR P 500.com 1300 1578 1795 2417 2750 3300 4367 5000 5700 MAIOR P 400.3/230-400V/50Hz MAIOR P 80 PR .1 PR .3/230-400V/50Hz MODEL Two stage progressive mechanical LIGHT OIL BURNERS MAIOR 634 718 887 1053 1265 1433 490 422 350 250 45 60 80 120 150 200 MAX OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT SILENCER TL TL TL TL TL TL TC TL TC TL TC TL TC TL TC TC TC TC TC TC BLAST TUBE on request on request on request on request on request on request 3143734 3143735 3143736 3143737 3143738 3143739 3143740 3143741 on request on request on request on request on request on request CODE .3/230-400V/50Hz MAIOR P 200.3/230-400V/50Hz MAIOR P 120 PR .ACCESSORIES 296 415 474 830 592 710 MIN MAIOR P 45 PR .3/400V/50Hz MAIOR P 1800.1 PR .1 PR .22 www.3/230-400V/50Hz MAIOR P 60 PR .1 PR .3/400V/50Hz MAIOR P 600.1 PR .ecoflam-burners.1 PR .3/400V/50Hz OUTPUT [kW] 7500 8500 10500 12500 15000 17000 5800 5000 3900 3000 532 710 949 1423 1780 2372 MAX 205 234 281 371 422 481 153 134 110 85 25 35 40 70 50 60 MIN FLOW RATE [kg/h] MAIOR .1 PR . Silencer Modulation kit Probe Pumping unit Kit Wieland plugs DESCRIPTION KIT .1 PR . 1 to 1200.1 • SLIDING BAR SYSTEM for MAXFLAM 10 to 50 and OILFLAM 300. If main supply is three-phase 230V/50Hz see • M100 version for heavy oil up to 100°E at 50°C • From OILFLAM 300. including filter and flexible hoses up to 6 MW.Max visc. Easy maintenance system is integrated into the burner: • HINGE FLANGE SYSTEM for OILFLAM 80.Max visc.ACS (see dedicated pages) .1 to 200. 50°E at 50°C HEAVY OIL BURNERS instruction manual for adjustments and modifications. OILFLAM models over 7 MW are offered on request based on the configuration requested (mechanical or electronic) in order to better fit into the application and provide a customised and more cost effective solution.ecoflam-burners. MAXFLAM .1 OILFLAM models from 300.1 are supplied with “GEFRAN” digital thermo regulator integrated on the front panel for granting temperature stability of fuel.1 and 1500. OILFLAM . Available version includes double stage up to 350 kg/h and from the model OILFLAM 300.www.1 to 1800.com 23 All heavy oil burners are delivered with electrical pre-heater preassembled into the burner body. MAXFLAM and OILFLAM range work with heavy oil up to 50°E at 50°C with On/Off switch to exclude the circuit heaters in order to operate also with low viscosity heavy oil. All burners 230-400V/50Hz are factory tested at 400V/50Hz ! three-phase. DUOBLOCK and ELECTRONIC versions are available on request for selected output to match main boilers and industry application.1 pre-heater can be supplied separately with extra cost • Forced oil preparation ring system on request AVAILABLE CONFIGURATIONS ON REQUEST • KIT Wieland plugs • KIT magnetic + selfcleaning filter • PID modulating KIT and probe • Silencer (starting from platform 260) KIT . 50°E at 50°C M100 configuration for heavy oil up to 100°E at 50°C is available on request.1 in progressive operation that can be turned in modulating with a PID regulator. ecoflam-burners.50°E fuel viscosity at 50°C MIN 205 MAXFLAM 50 AB .1 AB .1 AB Z3 .3/230-400V/50Hz OILFLAM 120.5 60 60 60 41 MIN 343 264 184 148 122 82 MAX FLOW RATE [kg/h] FLOW RATE [kg/h] FLOW RATE [kg/h] 18 18 MIN 15 9.5 6 MIN 50 36 MAX 30 20 12 MAX OPT OPT OPT OPT OPT OPT SILENCER CODE 3142604 3142605 3142606 3142607 3142608 3142609 3142610 3142611 3143753 3143754 3143755 3143756 TC TL TC TL TC TL TC TL TC TL TC TL 3143330 3143331 3143332 3143333 TC TL TC TL BLAST TUBE CODE 3143324 3143325 3143326 3143327 3143328 3143329 TC TL TC TL TC TL BLAST TUBE CODE BLAST TUBE .3/230-400V/50Hz 464 682 682 682 1000 1300 OILFLAM 80.3/230-400V/50Hz OILFLAM 200.1 AB .1 AB .24 www.3/230-400V/50Hz MODEL MIN 108 MAXFLAM 20 .3/230-400V/50Hz OILFLAM 300.50°E fuel viscosity at 50°C 68 MIN MAXFLAM 10 .3/400V/50Hz MODEL Two stages .3/230-400V/50Hz OILFLAM 170.1 AB .1/230V/50Hz MODEL One stage .3/230-400V/50Hz OILFLAM 205 MAXFLAM 30 AB .3/400V/50Hz OILFLAM 400.1/230V/50Hz Two stages .50°E fuel viscosity at 50°C HEAVY OIL BURNERS MAXFLAM OUTPUT [kW] 3900 3000 2093 1700 1395 930 MAX OUTPUT [kW] OUTPUT [kW] 570 410 MAX 340 227 136 MAX 115 88.com 170 MAXFLAM 30 .1 AB . 3/400V/50Hz DESCRIPTION 7500 8500 10500 12500 15000 17000 5800 5000 3900 3000 1395 1700 2093 930 MAX 214 243 292 386 440 501 159 140 115 88.1 PR .50°E fuel viscosity at 50°C HEAVY OIL BURNERS OILFLAM 660 748 924 1097 1319 1495 510 440 343 264 122 148 184 82 MAX OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT SILENCER on request on request on request 3143757 3143758 3143759 3143760 3143761 3143762 3143763 3143764 on request on request on request on request on request on request TC TL TC TL TC TL TC TC TC TC TC TC on request CODE TL TL TL TC TL TL BLAST TUBE .3/230-400V/50Hz MIN OILFLAM 80.1 PR .3/230-400V/50Hz MODEL Two stage progressive mechanical .3/400V/50Hz OILFLAM 1800.1 PR .1 PR .5 60 60 60 41 MIN FLOW RATE [kg/h] OILFLAM .DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.3/400V/50Hz OILFLAM 400.1 PR .ACCESSORIES 464 OILFLAM 120.1 PR .3/230-400V/50Hz OILFLAM 170.3/400V/50Hz OILFLAM 500.1 PR .1 PR .3/400V/50Hz OILFLAM 700.3/230-400V/50Hz OILFLAM 200.3/400V/50Hz OILFLAM 600. Silencer Modulation kit Probe Heating and pumping unit Magnetic + self cleaning filter OUTPUT [kW] see accessories page see accessories page see accessories page see accessories page see accessories page 682 682 682 KIT .1 PR .1 PR .ecoflam-burners.1 PR .3/400V/50Hz OILFLAM 1000.1 PR .1 PR .com 25 1000 1300 1578 1795 2417 2750 3300 4367 5000 5700 OILFLAM 300.3/400V/50Hz OILFLAM 1500.www.3/400V/50Hz OILFLAM 1200.1 PR .3/400V/50Hz OILFLAM 800. Safety and operation thermostat 5. MAGNETIC + SELF CLEANING FILTER Service tanks + Pumps units. PRE-HEATER UNIT 1. Feeding and filtering system 2. Heating coil 7. Forced oil supply system “RING” STANDARD SYSTEM COMPOSITION FOR LIGHT OIL AND HEAVY OIL HEATING AND PUMPING UNIT FORCED OIL PREPARATION RING A 3 5 13 12 3 6 hot water pipe / steam pipe insulaon Return 7 electrical heang cable hot water pipe / steam pipe sez. Service tank 3. pressure 3 bar). OIL ! HEAVY WARNINGS 7 8 11 A 2 HEAVY OIL PREPARATION RING: SUGGESTED SCHEME B 10 1. Ring pumps 10. Main heavy oil storage tank 13. Additional Forced system “OIL RING” can be design and delivered assembled on skid/frame or offered as single component.com The filtering system operation: the first magnetic filter allows to separate all ferrous impurities contained in the oil and the second lamellar filter allows the final filtration of all impurities.26 www. Oil ring control pressure device 11. Quotation on request depending on output and configuration.ecoflam-burners. Burners 2. A-A : secon B-B 5 oil pipe T oil pipe T 4 9 B For heavy oil with more than 50°E at 50°C ECOFLAM recommends to decrease the maximum output of 10-20% and work in eccess of air in order to grant better operation and reduce maintenance. All installations using heavy oil burners have to be completed with a Forced oil preparation ring in order to guarantee oil supply to the burner at suitable temperature and pressure (temperature +/. Heating coil LEGENDA 1 1 . Fuel heating system for reducing oil viscosity plus service tank 3. Electric heaters 4. Load pumps 9. ACCESSORIES ECOFLAM heavy oil burners are delivered with electrical pre-heater assembled into the burner body or in a separate skid. Heating cable 12. Level switch (working + safety) 6. Self cleaning oil filter 8.80°C. www. EN676 configuration: • GasMultiBloc Dungs: compact double solenoid valve with integrated filter. • GasMultiBloc Dungs GB-LE 055 Class B: compact double solenoid valve with integrated filter. If main supply is three-phase 230V/50Hz see • CV: Continuous ventilation version • HT: High Temperature version • OEM and special application version only on request AVAILABLE CONFIGURATIONS ON REQUEST • LPG KIT • KIT Wieland plugs • PID modulating KIT and probe • Antivibration coupling and ball valve KIT . EXPORT configuration (other additional options to be added by installer in compliance with local safety regulations): • double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch.ecoflam-burners. • single solenoid valve Brahma E6G*SR P and EG12*L for MAX GAS 40-120 complete with min gas pressure switch. All MAX GAS are delivered for natural gas and can operate with LPG by changing the nozzle with a kit. All burners 230-400V/50Hz are factory tested at 400V/50Hz ! three-phase. MAX GAS two stages are complete with two stages MultiBloc valves MBZRDLE for the models 120-250 where models 350-500 operate in two stage with butterfly valve.ACS (see dedicated pages) .Low NOx class 3 (<80 mg/kWh) GAS BURNERS instruction manual for adjustments and modifications. • double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch + separate gas governor and filter FGDR. regulator and min pressure switch. Progressive version are availble for models MAX GAS 350-500 and can be transformed into modulating with the PID KITMD-RWF50.com 27 Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation. BBCH: Burner Body with Combustion Head → TC short head and TL long head GT: Gas train separate → EN676 or Export configuration KIT & ACS: kits and accessories according to local rules installation MAX GAS range is available in the following versions and is delivered in a modular system of boxes: • P: 1 stage soft start • PAB: 2 stages • PR: 2 stage progressive mechanical MAX GAS . regulator and min pressure switch available for MAX GAS 40-120. • single solenoid valve Kromschröder VAS125 and VAS240 for MAX GAS 170-250 complete with min gas pressure switch. com GT-D1-GBLE055-RP15-MAXGAS40-120 GT-H1-E6GSRP-RP15-MAXGAS40-120 GT-H1-EG12L-RP15-MAXGAS40-120 GT-K1-VAS125-RP25-MAXGAS170-250 GT-K1-VAS240-RP40-MAXGAS170-250 DESIGNATION GAS TRAIN .EN676 up to 70 kW single solenoid valve with min gas pressure switch single solenoid valve with min gas pressure switch single solenoid valve with min gas pressure switch single solenoid valve with min gas pressure switch OUTPUT [kW] One stage Low NOx class 3 (NOx <80 mg/kWh) GAS BURNERS MAX GAS 40-120 40-120 40-120 170-250 170-250 TYPE OF BURNER 9 9 9 9 10 11 16 18 10 11 16 18 16 18 34 36 16 18 34 36 16 18 34 36 16 18 34 36 65 200 65 200 360 360 65 200 360 360 65 200 360 360 65 200 360 360 65 200 360 360 65 200 360 360 65 200 PRESSURE [mbar] MIN MAX Ø 1/2" 1/2" 1/2" 1" 1"1/2 3141885 3123944 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 CODE MBC 65 DLE MB-DLE 403 MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 GAS TRAIN TYPE 1/2" 3/4" 1/2" 3/4" 1/2" 3/4" 1/2" 3/4" 1/2" 3/4" 1/2" 3/4" 1/2" 1/2" Ø CODE 3142027 3141888 3141887 3142815 3142816 included included included included included included included included GAS GOVERNOR AND FILTER .Export configuration 1/230V/50-60Hz MAX GAS 120 P TW 1/230V/50-60Hz MAX GAS 105 P TW 1/230V/50-60Hz MAX GAS 70 P TW 1/230V/50-60Hz MAX GAS 40 P TW MODEL 49 49 34 17 MIN 120 108 70 48 MAX DESCRIPTION 3142748 3142747 TC TL 3142746 3142745 TC TL 3142744 3142743 TC TL 3142742 3142741 TL TC BURNER BODY BLAST TUBE CODE MultiBloc class B .ecoflam-burners.28 www. com 29 120 100 55 55 500 350 240 175 OUTPUT [kW] MIN MAX 3143286 3143285 TC TL 3143284 3143283 TC TL 3142752 3142751 TC TL 3142750 3142749 TL TC BURNER BODY BLAST TUBE CODE 3/230-400V/50Hz MAX GAS 500 P TW 1/230V/50Hz MAX GAS 350 P TW 1/230V/50Hz MAX GAS 250 P TW 1/230V/50Hz MAX GAS 170 P TW MODEL 120 100 55 55 500 350 240 175 OUTPUT [kW] MIN MAX 3143286 3143285 TC TL 3143284 3143283 TC TL 3142752 3142751 TC TL 3142749 3142750 TC TL BURNER BODY BLAST TUBE CODE One stage Low NOx class 3 (NOx <80 mg/kWh) .ecoflam-burners.www.1/230/50-60Hz 3/230-400V/50Hz MAX GAS 500 P TW 1/230V/50Hz MAX GAS 350 P TW 1/230V/50Hz MAX GAS 250 P TW 1/230V/50Hz MAX GAS 170 P TW MODEL 20 20 15 34 15 34 18 54 18 54 24 98 24 98 500 500 500 500 500 500 500 500 360 360 360 360 360 360 360 360 PRESSURE [mbar] MIN MAX 13 17 26 13 17 26 15 17 26 40 15 17 26 40 17 20 37 60 17 20 37 60 20 35 55 90 20 35 55 90 PRESSURE [MBAR] MIN MAX 3141906 3141906 3142251 3141906 3142251 3141906 3142375 3142374 3142375 3142374 3142375 3142374 3142375 3142374 CODE 3123947 3123525 3123560 3123947 3123525 3123560 3141899 3123947 3123525 3123560 3141899 3123947 3123525 3123560 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 CODE VCS-125 VCS-125 VCS-240 VCS-125 VCS-240 VCS-125 VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500 GAS TRAIN TYPE MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 412 MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 412 MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 GAS TRAIN TYPE 1" 1" 1"1/2 1" 1"1/2 1" 1"1/2 1" 1"1/2 1" 1"1/2 1" 1"1/2 1" Ø 1" 3/4" 3/4" 1" 3/4" 3/4" 1"1/4 1" 3/4" 3/4" 1"1/4 1" 3/4" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" Ø 3142521 3142521 3142523 3142521 3142523 3142521 3142523 3142521 3142523 3142521 3142523 3142521 3142523 3142521 FGDR 1" FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" GAS GOVERNOR AND FILTER CODE TYPE included included included included 3122300 included 3122300 included 3122300 included 3122300 included GAS GOVERNOR + FILTER KIT ADAPTOR .VCS gas train versions . 30 www.com 3/230-400V/50Hz MAX GAS 500 PAB TW 1/230V/50Hz MAX GAS 350 PAB TW 1/230V/50Hz MAX GAS 250 PAB TW 1/230V/50Hz MAX GAS 170 PAB TW 1/230V/50-60Hz MAX GAS 120 PAB MODEL 120 100 55 55 40 MIN 500 350 240 175 120 MAX OUTPUT [kW] Two stages Low NOx class 3 (NOx <80 mg/kWh) 3143290 3143289 TC TL 3143288 3143287 TC TL 3142785 3142784 TC TL 3142783 3142782 TC TL 3123955 TC TL CODE 3123954 BLAST TUBE BURNER BODY 90 55 3142392 3142665 3142295 360 35 3142392 3142296 20 90 3142665 35 360 3142296 3142295 20 55 3142392 60 3142665 3142295 360 20 37 3142296 3142392 17 60 3142665 3142295 20 37 3142296 360 3123960 17 3123961 40 26 3123962 17 360 3141901 3123960 3123961 15 40 26 3141901 3123962 15 17 360 3123962 3123961 3123960 360 3123960 26 17 13 26 3123962 3123960 3123961 360 CODE 3123960 13 360 360 MAX 17 16 16 MIN PRESSURE [mbar] MB-DLE 407 350/500 MB-DLE 410 350/500 MB-DLE 412 350/500 MB-DLE 415 350/500 MB-DLE 407 350/500 MB-DLE 410 350/500 MB-DLE 412 350/500 MB-DLE 415 350/500 MB-DLE 407 350/500 MB-DLE 410 350/500 MB-DLE 412 350/500 MB-DLE 415 350/500 MB-DLE 407 350/500 MB-DLE 410 350/500 MB-DLE 412 350/500 MB-DLE 415 350/500 MB-ZRDLE 405 MB-ZRDLE 407 MB-ZRDLE 410 MB-ZRDLE 412 MB-ZRDLE 405 MB-ZRDLE 407 MB-ZRDLE 410 MB-ZRDLE 412 MB-ZRDLE 405 MB-ZRDLE 407 MB-ZRDLE 410 MB-ZRDLE 405 MB-ZRDLE 407 MB-ZRDLE 410 MB-ZRDLE 405 MB-ZRDLE 405 TYPE GAS TRAIN Ø 3/4" 1" 1"1/4 1"1/2 3/4" 1" 1"1/4 1"1/2 3/4" 1" 1"1/4 1"1/2 3/4" 1" 1"1/4 1"1/2 3/4" 3/4" 1" 1"1/4 3/4" 3/4" 1" 1"1/4 3/4" 3/4" 1" 3/4" 3/4" 1" 3/4" 3/4" included included included included 3122300 included 3122300 included 3122300 included 3122300 included included included GAS GOVERNOR AND FILTER KIT ADAPTOR .ecoflam-burners. ecoflam-burners.VCS gas train versions 500 500 500 500 17 20 37 60 17 20 37 60 20 35 55 90 20 35 55 90 360 360 360 360 PRESSURE [mbar] MIN MAX 18 54 18 54 14 18 54 14 18 54 PRESSURE [mbar] MIN MAX 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 CODE 3142375 3142374 3142375 3142374 3142376 3142375 3142374 3142376 3142375 3142374 CODE MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 GAS TRAIN TYPE VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500 VCS-350 350/500 VCS-240 350/500 VCS-125 350/500 VCS-350 350/500 VCS-240 350/500 VCS-125 350/500 GAS TRAIN TYPE 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" Ø 1"1/2 1" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" Ø FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" included included included included GAS GOVERNOR AND FILTER 3142523 3142521 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 GAS GOVERNOR AND FILTER CODE TYPE .ACCESSORIES 3/230-400V/50Hz MAX GAS 500 PR TW 1/230V/50Hz MAX GAS 350 PR TW MODEL 120 100 3140050 3140049 TC TL 3140048 3140047 TL TC BURNER BODY BLAST TUBE CODE see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page 500 350 OUTPUT [kW] MIN MAX Two stage progressive mechanical Low NOx class 3 (NOx <80 mg/kWh) 3/230-400V/50Hz MAX GAS 500 PAB TW 1/230V/50Hz MAX GAS 350 PAB TW MODEL Two stages Low NOx class 3 (NOx <80 mg/kWh) .com 31 120 100 500 350 OUTPUT [kW] MIN MAX 3143290 3143289 TC TL 3143288 3143287 TL TC BURNER BODY BLAST TUBE CODE Tightness control Modulation kit Probe LPG kit Adaptor kit for gas train Additional gas accessories DESCRIPTION KIT .www. ecoflam-burners.32 www. KIT CODE - - 3122300 3122300 - ADAPT. KIT CODE .LPG versions 360 360 360 360 65 65 65 65 360 360 360 360 360 52 33 360 360 PRESSURE [mbar] MIN MAX 52 33 34 23 15 PRESSURE [mbar] MIN MAX 52 33 34 23 24 24 15 7 PRESSURE [mbar] MIN MAX 3142392 3142392 CODE 3142392 3142392 3123960 3123960 3123960 CODE 3122392 3122392 3123560 3123560 3141885 3141885 3141885 3141885 CODE MB-DLE 407 350/500 MB-DLE 407 350/500 GAS TRAIN TYPE MB-DLE 407 350/500 MB-DLE 407 350/500 MB-ZRDLE 405 MB-ZRDLE 405 MB-ZRDLE 405 GAS TRAIN TYPE MB-DLE 407 350/500 MB-DLE 407 350/500 MB-DLE 405 MB-DLE 405 MBC 65 DLE MBC 65 DLE MBC 65 DLE MBC 65 DLE GAS TRAIN TYPE 3/4" 3/4" Ø 3/4" 3/4" 3/4" 3/4" 3/4" Ø 3/4" 3/4" 3/4" 3/4" 1/2" 1/2" 1/2" 1/2" Ø 3142431 3142431 LPG KIT CODE 3142431 3142431 3122302 3122302 3122301 LPG KIT CODE 3142431 3142431 3122302 3122302 3122301 3122301 3122301 3122301 LPG KIT CODE - - ADAPT.LPG versions 3/230-400V/50Hz MAX GAS 500 P TW 1/230V/50Hz MAX GAS 350 P TW 1/230V/50Hz MAX GAS 250 P TW 1/230V/50Hz MAX GAS 170 P TW 1/230V/50-60Hz MAX GAS 120 P TW 1/230V/50-60Hz MAX GAS 105 P TW 1/230V/50-60Hz MAX GAS 70 P TW 1/230V/50-60Hz MAX GAS 40 P TW MODEL One stage Low NOx class 3 (NOx <80 mg/kWh) . KIT CODE - - 3122300 3122300 - - - - ADAPT.com 120 100 55 55 49 49 34 17 500 350 240 175 120 108 70 48 OUTPUT [kW] MIN MAX TC TL TC TL TC TL TC TL TC TL TC TL TC TL TC TL 120 100 55 55 40 500 350 240 175 120 OUTPUT [kW] MIN MAX TC TL TC TL TC TL TC TL TC TL 3123954 3123955 3142782 3142783 3142784 3142785 3143287 3143288 3143289 3143290 BURNER BODY BLAST TUBE CODE 3/230-400/50Hz MAX GAS 500 PR TW 1/230/50Hz MAX GAS 350 PR TW MODEL 120 100 500 350 OUTPUT [kW] MIN MAX TC TL TC TL 3140047 3140048 3140049 3140050 BURNER BODY BLAST TUBE CODE Two stage progressive mechanical Low NOx class 3 (NOx <80 mg/kWh) .LPG versions 3/230-400/50Hz MAX GAS 500 PAB TW 1/230/50Hz MAX GAS 350 PAB TW 1/230/50Hz MAX GAS 250 PAB TW 1/230/50Hz MAX GAS 170 PAB TW 1/230/50-60Hz MAX GAS 120 PAB MODEL 3142741 3142742 3142743 3142744 3142745 3142746 3142747 3142748 3142749 3142750 3142751 3142752 3143283 3143284 3143285 3143286 BURNER BODY BLAST TUBE CODE Two stages Low NOx class 3 (NOx <80 mg/kWh) . Low NOx class 3 (<80 mg/kWh) and class 2 (<120 mg/kWh) GAS BURNERS .. Maximum pressure switch as option or in compliance with local safety regulations. • double solenoid valves VCS Kromschröder: double solenoid valves including minimum gas pressure switch + separate gas governor and filter FGDR.1 FGDR: Gas governor and filter for double solenoid valves VCS Kromschröder FILTER: for double gas valves VGD Siemens KITTC-.1.1 • KIT Wieland plugs • PID modulating KIT and probe • Antivibration coupling and ball valve • Silencer (starting from platform 260) KIT . • KITTC-.: Maximum pressure switch KIT & ACS can be added according to local rules installations (silencer.22 mbar. EXPORT configuration (others additional options to be added by installer in compliance with local safety regulations): • double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch. BBCH: Burner body with combustion head → TC short head and TL long head GT: Gas train separate → EN676 or Export configuration GTCP: Connection pipe between burner and gas train starting from model 1700. • double gas valves with actuators and regulator VGD Siemens§ + gas filter. antivibration coupling.. EN676 configuration: • GasMultiBloc Dungs: compact double solenoid valve with integrated filter.1 change spring and damping (see pag... • double gas valves with actuators and regulator VGD Siemens§...) BLU range is available in the following versions and is delivered in a modular system of boxes: • PAB: 2 stages • PR: 2 stages progressive mechanical BLU .www. 53). regulator and min pressure switch up to model BLU 2000. Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation. • KITPRES. head pressure 0.. from BLU 300.ecoflam-burners.... If main supply is three-phase 230V/50Hz see • CV: Continuous ventilation version • OEM and special application version only on request • KITSWIRL: Swirl system for flame customized in our Flexshop AVAILABLE CONFIGURATIONS ON REQUEST • LPG KIT up to Blu 2000. Tightness control device must be included over 1200 kW according to EN676.ACS (see dedicated pages) § VGD Siemens: default blank spring.. ! three-phase. ball valve.: Tightness control kit to be included over 1200 kW according to EN676 KITPRES-.com 33 All burners 230-400V/50Hz are factory tested at 400V/50Hz instruction manual for adjustments and modifications.. 503 VCS 350 VCS 240 VGD 40.503 VCS 350 VCS 240 VGD 40.1 PAB Low NOx 3/230-400/50Hz BLU 1200.1 PAB Low NOx MODEL 1550 1100 875 700 245 970 OUTPUT [kW] MIN MAX 300 290 280 270 OUTPUT [kW] MIN MAX Two stages Low NOx (NOx <80 mg/kWh) GAS BURNERS BLU TL TC 3124015 3124014 BURNER BODY BLAST TUBE CODE 3140313 3140312 TC TL 3140310 3140309 TC TL 3140304 3140303 TC TL 3124013 3124012 TL TC BURNER BODY BLAST TUBE CODE OPT OPT SILENCER OPT OPT OPT OPT OPT OPT OPT OPT SILENCER - - CONNECTION PIPE - 3141842 3142076 - 3141842 3142076 - - - - - - CONNECTION PIPE 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 25 55 165 25 55 165 500 500 PRESSURE [mbar] MIN MAX 15 30 175 15 30 175 30 60 170 30 60 170 20 30 65 20 30 65 30 40 60 130 30 40 60 130 PRESSURE [mbar] MIN MAX 3141862 3142025 3142024 3141862 3142025 3142024 CODE 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025 3124110 3123860 3141862 3142025 3124110 3123860 3141862 3142025 CODE VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 GAS TRAIN TYPE VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.ecoflam-burners.1 PAB MODEL Two stages 3/230-400/50Hz BLU 1500.1 PAB Low NOx 3/230-400/50Hz BLU 1000.1 PAB Low NOx 3/230-400/50Hz BLU 700.34 www.065 VGD 20.503 VCS 350 VCS 240 VGD 20.065 VGD 20.503 VCS 350 VCS 240 GAS TRAIN TYPE 2" 1"1/2 1" 2" 1"1/2 1" Ø 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2 2"1/2 2" 2" 1"1/2 2"1/2 2" 2" 1"1/2 Ø FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2 3142524 3142523 3142523 3142524 3142523 3142523 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 GAS GOVERNOR AND FILTER CODE TYPE 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3121384 3142524 3142523 3121384 3142524 3142523 3124111 3121384 3142524 3142523 3124111 3121384 3142524 3142523 GAS GOVERNOR AND FILTER CODE TYPE .com 3/230-400/50Hz BLU 1000. 503 VCS 350 VCS 240 VGD 40.080 VGD 40.ecoflam-burners.065 VGD 20.1 PAB MODEL OPT OPT OPT OPT OPT OPT SILENCER OPT OPT OPT OPT OPT OPT SILENCER - - - - - - CONNECTION PIPE 3142074 3142069 3142197 3142074 3142069 3142197 3142074 3142069 3142074 3142069 - - CONNECTION PIPE 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 15 30 175 15 30 175 30 60 170 30 60 170 20 30 65 20 30 65 500 500 500 500 500 500 500 500 500 500 PRESSURE [mbar] MIN MAX 25 35 80 25 35 80 20 45 65 150 20 45 65 150 23 35 60 90 220 23 35 60 90 220 PRESSURE [mbar] MIN MAX 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025 CODE 3123860 3141862 3142025 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 CODE VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.065 VGD 20.www.503 VCS 350 VCS 240 VGD 20.503 VCS 350 VCS 240 VGD 20.com 35 414 342 260 2150 1770 1200 OUTPUT [kW] MIN MAX 3140331 3140330 TC TL 3140327 3140326 TC TL 3124017 3124016 TL TC BURNER BODY BLAST TUBE CODE 3/230-400/50Hz BLU 1200.1 PAB 3/230-400/50Hz BLU 1200.503 VCS 350 VCS 240 VGD 40.1 PAB 3/230-400/50Hz BLU 1700.080 VGD 40.1 PR Low NOx MODEL 290 280 270 1100 875 700 OUTPUT [kW] MIN MAX 3140397 3140396 TC TL 3140391 3142587 TC TL 3123886 3124030 TL TC BURNER BODY BLAST TUBE CODE Two stage progressive mechanical Low NOx class 3 (NOx <80 mg/kWh) 3/230-400/50Hz BLU 2000.1 PR Low NOx 3/230-400/50Hz BLU 700.080 VGD 20.1 PR Low NOx 3/230-400/50Hz BLU 1000.503 VCS 350 VCS 240 GAS TRAIN TYPE 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2 Ø 2" 2" 1"1/2 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2 Ø Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3121384 3142524 3142523 3121384 3142524 3142523 FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 GAS GOVERNOR AND FILTER CODE TYPE 3121384 3142524 3142523 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 GAS GOVERNOR AND FILTER CODE TYPE .080 VGD 20.503 VCS 350 VCS 240 VGD 40.503 VCS 350 VCS 240 GAS TRAIN TYPE VGD 20.503 VCS 350 VCS 240 VGD 40. 503 VCS 350 VCS 240 VGD 40.080 VGD 20.065 VGD 20.36 www.065 VGD 20.503 VCS 350 VCS 240 VGD 40.503 VCS 350 VCS 240 VGD 20.080 VGD 40.503 VCS 350 VCS 240 VGD 40.1 PR 3/230-400/50Hz BLU 1200.1 PR Low NOx MODEL 3140400 3124109 3140404 3140403 TC TL 3140402 3140401 TC TL 3124034 3124033 TC TL 3124032 3124031 TL TC BURNER BODY BLAST TUBE CODE TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT OPT OPT SILENCER OPT OPT SILENCER 3142074 3142069 3142197 3142074 3142069 3142197 3142074 3142069 3142074 3142069 - - - - CONNECTION PIPE - 3141842 3142076 - 3141842 3142076 CONNECTION PIPE 500 500 500 500 500 500 500 500 25 55 165 25 55 165 25 35 80 25 35 80 20 45 65 150 20 45 65 150 23 35 60 90 220 23 35 60 90 220 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 PRESSURE [mbar] MIN MAX 30 40 60 130 30 40 60 130 PRESSURE [mbar] MIN MAX 3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 CODE 3124110 3123860 3141862 3142025 3124110 3123860 3141862 3142025 CODE VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.1 PR 3/230-400/50Hz BLU 1700.503 VCS 350 VCS 240 VGD 40.1 PR MODEL 414 342 260 245 2150 1770 1200 970 OUTPUT [kW] MIN MAX 1550 OUTPUT [kW] MIN MAX Two stage progressive mechanical 3/230-400/50Hz BLU 1500.080 VGD 20.503 VCS 350 VCS 240 VGD 40.1 PR 3/230-400/50Hz BLU 1000.503 VCS 350 VCS 240 GAS TRAIN TYPE VGD 40.com 300 3/230-400/50Hz BLU 2000.503 VCS 350 VCS 240 GAS TRAIN TYPE 2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 DN65 2" 2" 1"1/2 DN80 DN65 2" 2" 1"1/2 Ø 2"1/2 2" 2" 1"1/2 2"1/2 2" 2" 1"1/2 Ø Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2 3142524 3142523 3142523 3142524 3142523 3142523 3121384 3142524 3142523 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 GAS GOVERNOR AND FILTER CODE TYPE 3124111 3121384 3142524 3142523 3124111 3121384 3142524 3142523 GAS GOVERNOR AND FILTER CODE TYPE .080 VGD 40.065 VGD 20.065 VGD 20.ecoflam-burners. 1 PAB MODEL 3/230-400/50Hz BLU 1500.1 PAB 3/230-400/50Hz BLU 1700.1 PAB Low NOx 3/230-400/50Hz BLU 1000.1 PAB Low NOx 3/230-400/50Hz BLU 700.com 37 3/230-400/50Hz BLU 2000.1 PAB Low NOx 3/230-400/50Hz BLU 1200.ecoflam-burners.1 PAB 3/230-400/50Hz BLU 1000.1 PAB Low NOx MODEL 1550 1100 875 700 414 342 260 245 2150 1770 1200 970 OUTPUT [kW] MIN MAX 300 290 280 270 OUTPUT [kW] MIN MAX Two stages .1 PAB 3/230-400/50Hz BLU 1200.MultiBloc gas train 3140331 3140330 TC TL 3140327 3140326 TL TC 3124017 3124016 TC TL 3124015 3124014 TL TC BURNER BODY BLAST TUBE CODE 3140313 3140312 TC TL 3140310 3140309 TC TL 3140304 3140303 TC TL 3124013 3124012 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT OPT OPT SILENCER OPT OPT OPT OPT OPT OPT OPT OPT SILENCER 3142074 3142074 3142074 3142074 - - - - CONNECTION PIPE 3142076 3142076 - - - - - - CONNECTION PIPE 360 360 360 360 360 360 360 360 27 35 75 27 35 75 40 50 100 40 50 100 60 85 60 85 75 100 75 100 360 360 360 360 360 360 360 360 PRESSURE [mbar] MIN MAX 17 25 75 17 25 75 35 40 75 35 40 75 35 45 85 35 45 85 60 70 60 70 PRESSURE [mbar] MIN MAX 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846 3141847 3141846 3141847 3141846 CODE 3141847 3141846 3142022 3141847 3141846 3142022 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846 CODE MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 GAS TRAIN TYPE MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 GAS TRAIN TYPE 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/2 Ø 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2 Ø included included included included included included included included GAS GOVERNOR AND FILTER included included included included included included included included GAS GOVERNOR AND FILTER .www. 1 PR Low NOx 3/230-400/50Hz BLU 700.1 PR 3/230-400/50Hz BLU 1200.1 PR Low NOx 3/230-400/50Hz BLU 1000.ecoflam-burners.1 PR 3/230-400/50Hz BLU 1000.1 PR Low NOx MODEL 1550 1100 875 700 414 342 260 245 2150 1770 1200 970 OUTPUT [kW] MIN MAX 300 290 280 270 OUTPUT [kW] MIN MAX Two stage progressive mechanical 3140404 3140403 TC TL 3140402 3140401 TC TL 3124034 3124033 TC TL 3124032 3124031 TL TC BURNER BODY BLAST TUBE CODE 3140400 3124109 TC TL 3140397 3140396 TC TL 3140391 3142587 TC TL 3123886 3124030 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT OPT OPT SILENCER OPT OPT OPT OPT OPT OPT OPT OPT SILENCER 3142074 3142074 3142074 3142074 - - - - CONNECTION PIPE 3142076 3142076 - - - - - - CONNECTION PIPE 360 360 360 360 360 360 360 360 27 35 75 27 35 75 40 50 100 40 50 100 60 85 60 85 75 100 75 100 360 360 360 360 360 360 360 360 PRESSURE [mbar] MIN MAX 17 25 75 17 25 75 35 40 75 35 40 75 35 45 85 35 45 85 60 70 60 70 PRESSURE [mbar] MIN MAX 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846 3141847 3141846 3141847 3141846 CODE 3141847 3141846 3142022 3141847 3141846 3142022 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846 CODE MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 GAS TRAIN TYPE MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB -DLE 412 MB-DLE 420 MB-DLE 415 MB -DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 GAS TRAIN TYPE 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/2 Ø 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2 Ø included included included included included included included included GAS GOVERNOR AND FILTER included included included included included included included included GAS GOVERNOR AND FILTER .com 3/230-400/50Hz BLU 2000.38 www.1 PR Low NOx 3/230-400/50Hz BLU 1200.1 PR MODEL 3/230-400/50Hz BLU 1500.1 PR 3/230-400/50Hz BLU 1700. 125 VGD 40..080 VGD 40.080 VGD 40.080 VGD 40.080 VGD 40.100 VGD 40.080 VGD 40.1 change spring and damping (see pag.www. 53) 3/400/50Hz BLU 6000. head pressure 0.503 VGD 40.080 VGD 40.1 PR 3/400/50Hz BLU 5000.503 VGD 40.080 VGD 40.503 VGD 40.1 PR 3/400/50Hz BLU 3000.ecoflam-burners.065 VGD 20.100 VGD 40.503 VGD 40.065 VGD 20.080 VGD 40.065 VGD 20.065 VGD 20..125 VGD 40. from BLU 3000.100 VGD 40.503 VGD 40.503 VGD 40.100 VGD 40.065 VGD 20.125 VGD 40.100 VGD 40.065 VGD 20.com 39 1500 1200 875 630 5800 5000 3900 3000 OUTPUT [kW] MIN MAX 3141762 3141761 TC TL 3141759 3141758 TC TL 3141757 3141756 TC TL 3141754 3141753 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT OPT OPT SILENCER 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 CONNECTION PIPE 500 500 500 500 100 180 340 500 60 60 500 500 500 500 75 140 250 50 500 500 500 500 500 45 100 180 340 50 500 500 500 500 500 45 75 140 250 35 500 500 500 500 500 500 500 50 90 170 50 90 170 35 500 30 500 500 500 500 35 55 100 30 500 500 500 500 35 55 100 22 500 22 PRESSURE [mbar] MIN MAX 3142026 3124110 3123860 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3141869 3142026 3124110 3123860 3141869 3142026 3124110 3123860 3141869 CODE ! § VGD Siemens: default blank spring.065 VGD 20.100 GAS TRAIN (§) TYPE DN80 DN65 2" DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN100 DN80 DN65 2" DN100 DN80 DN65 2" DN100 Ø 3142088 3124111 3121384 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142205 3142088 3124111 3121384 3142205 3142088 3124111 3121384 3142205 Filter DN80 Filter DN65 Filter 2" Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN100 GAS GOVERNOR AND FILTER CODE TYPE .1 PR MODEL Two stage progressive mechanical VGD 40.503 VGD 40.503 VGD 40.125 VGD 40.100 VGD 40.100 VGD 40.065 VGD 20.22 mbar.1 PR 3/400/50Hz BLU 4000. 065 VGD 40.100 VGD 40..100 VGD 40.080 VGD 40.ACCESSORIES ! § VGD Siemens: default blank spring.22 mbar.1 PR 3/400/50Hz BLU 8000.065 VGD 40.ecoflam-burners.1 PR 3/400/50Hz BLU 10000.125 VGD 40.1 change spring and damping (see pag.1 PR 3/400/50Hz BLU 15000.080 VGD 40.125 VGD 40.080 VGD 40.100 VGD 40. 53) 3/400/50Hz BLU 18000.1 PR MODEL VGD 40.125 VGD 40.1 PR BLU 7000.065 VGD 40.100 VGD 40. head pressure 0.com 3/400/50Hz 4000 3690 2700 2500 2000 1500 17000 15000 13000 10500 8500 7500 OUTPUT [kW] MIN MAX TC TC TC TC TC TC 3143752 3143751 3143750 3143749 3143748 3143747 BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT SILENCER 3142422+ 3142425 3142422 3142424 3142423 3142422+ 3142425 3142422 3142424 3142423 3142422+ 3142425 3142422 3142424 3142423 3142422+ 3142425 3142422 3142424 3142422+ 3142425 3142422 3142424 3142422+ 3142425 3142422 CONNECTION PIPE 330 210 230 450 150 230 420 175 165 290 550 115 110 210 410 85 75 140 280 60 500 500 500 500 500 500 PRESSURE [mbar] MIN MAX 3141869 3142666 3141869 3142026 3142666 3141869 3142026 3142666 3141869 3142026 3124110 3142666 3141869 3142026 3124110 3142666 3141869 3142026 3124110 3142666 CODE see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page Tightness control Modulation kit Probe LPG kit Adaptor kit for gas train Additional gas accessories BLU .080 VGD 40.1 PR 3/400/50Hz BLU 12000.125 GAS TRAIN (§) TYPE DN100 DN125 DN100 DN80 DN125 DN100 DN80 DN125 DN100 DN80 DN65 DN125 DN100 DN80 DN65 DN125 DN100 DN80 DN65 DN125 Ø 3142205 3142206 3142205 3142088 3142206 3142205 3142088 3142206 3142205 3142088 3124111 3142206 3142205 3142088 3124111 3142206 3142205 3142088 3124111 3142206 Filter DN100 Filter DN125 Filter DN100 Filter DN80 Filter DN125 Filter DN100 Filter DN80 Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter DN125 GAS GOVERNOR AND FILTER CODE TYPE .100 VGD 40.100 VGD 40.40 www.125 VGD 40.DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.080 VGD 40. from BLU 3000.125 VGD 40.. see accessories page Silencer DESCRIPTION KIT . ball valve.1 change spring and damping (see pag. • KITTC-.oil MULTICALOR DUAL FUEL BURNERS (GAS/LIGHT OIL) . EXPORT configuration (others additional options to be added by installer in compliance with local safety regulations): • Double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch • Double gas valves with actuators and regulator VGD Siemens§ EN676 configuration: • GasMultiBloc Dungs: compact double solenoid valve with integrated filter.www.ACS (see dedicated pages) § VGD Siemens: default blank spring.com 41 All burners 230-400V/50Hz are factory tested at 400V/50Hz instruction manual for adjustments and modifications.1 . Standard version running on manual fuel selection mode and on request kit for automatic fuel changeover. BBCH: Burner body with combustion head → TC short head and TL long head.soft start light oil • PR: 2 stage progressive mechanical gas .: Tightness control kit to be included over 1200 kW according to EN676 KITPRES. • KITPRES. Maximum pressure switch as option or in compliance with local safety regulations. If main supply is three-phase 230V/50Hz see • CV: Continuous ventilation version • OEM and special application version only on request • KITSWIRL: Swirl system for flame customized in our Flexshop AVAILABLE CONFIGURATIONS ON REQUEST • LPG KIT up to MULTICALOR 200..22 mbar..1.: Maximum pressure switch KIT & ACS can be added according to local rules installations (silencer.) MULTICALOR is available in the following versions and is delivered in a modular system of boxes: • AB: 2 stages gas and light oil / soft start light oil • PR-AB: 2 stage progressive mechanical gas / 2 stages light oil . The automatic changeover system can be triggered by a gas pressure switch or by a timer.1 • KIT automatic fuel changeover • PID modulating KIT and probe • KIT Wieland plugs • Antivibration coupling and ball valve • Silencer (starting from platform 260) KIT . head pressure 0.. Tightness control device must be included over 1200 kW according to EN676... Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation.. antivibration coupling. • double gas valves with actuators and regulator VGD Siemens§ + gas filter.1.. from MULTICALOR 300. regulator and min pressure switch up to model MULTICALOR 200.1800... 53).1 FGDR: Gas governor and filter for double solenoid valves VCS Kromschröder FILTER for double gas valves VGD Siemens KITTC-. Easy maintenance system with hinge flange for models 1500.. ! three-phase. • double solenoid valves VCS Kromschröder: double solenoid valves including minimum gas pressure switch + separate gas governor and filter FGDR.. GT: Gas train separate → EN676 or Export configuration GTCP: Connection pipe between burner and gas train starting from model 170.ecoflam-burners.. 42 www.065 VGD 20.080 VGD 40.080 VGD 20.065 VGD 20.1 3/230-400/50Hz MULTICALOR 140 3/230-400/50Hz MULTICALOR 100 3/230-400/50Hz MULTICALOR 70 3/230-400/50Hz MULTICALOR 45 MODEL 414 342 400 300 250 190 2150 1770 1300 1000 700 500 OUTPUT [kW] MIN MAX Two stages gas / Two stages light oil 3142631 3142630 TC TL 3142629 3142628 TC TL 3140438 3140439 TC TL 3140432 3140433 TC TL 3140430 3140431 TC TL 3140428 3140429 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT - - SILENCER DUAL FUEL BURNERS (GAS/LIGHT OIL) MULTICALOR 3142075 3142069 3142197 3142075 3142069 3142197 3142075 3142069 3142075 3142069 - - - - - - - - CONNECTION PIPE 17 90 17 90 15 30 170 15 30 170 25 40 165 25 40 165 25 35 80 25 35 80 20 45 65 150 20 45 65 150 23 35 60 90 220 23 35 60 90 220 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 PRESSURE [mbar] MIN MAX 3142025 3142024 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 CODE VCS 240 VCS 125 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.503 VCS 350 VCS 240 GAS TRAIN TYPE 1"1/2 1" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2 Ø 3142523 3142521 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142523 3142524 3142523 3142523 3121384 3142524 3142523 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 GAS GOVERNOR AND FILTER CODE TYPE .080 VGD 20.503 VCS 350 VCS 240 VGD 20.com 3/230-400/50Hz MULTICALOR 200.1 3/230-400/50Hz MULTICALOR 170.503 VCS 350 VCS 240 VGD 40.080 VGD 40.503 VCS 350 VCS 240 VGD 40.ecoflam-burners.503 VCS 350 VCS 240 VGD 40.503 VCS 350 VCS 240 VGD 40. ecoflam-burners.080 VCS 240 VCS 350 VGD 20.503 VGD 40.065 VGD 40.080 VCS 240 VCS 350 VGD 20.503 VGD 40.1 PR-AB 3/230-400/50Hz MULTICALOR 170.503 VCS 125 VCS 240 VCS 350 VCS 125 VCS 240 VCS 350 VCS 125 VCS 240 VCS 350 VCS 125 VCS 240 VCS 350 GAS TRAIN TYPE 1"1/2 2" 2" 2"1/2 DN80 1"1/2 2" 2" 2"1/2 DN80 1"1/2 2" 2" DN80 1"1/2 2" 2" DN80 1"1/2 2" 2" 1"1/2 2" 2" 1" 1"1/2 2" 1" 1"1/2 2" 1" 1"1/2 2" 1" 1"1/2 2" Ø 3142523 3142524 3121384 3124111 3142088 3142523 3142524 3121384 3124111 3142088 3142523 3142524 3121384 3142088 3142523 3142524 3121384 3142088 3142523 3142524 3121384 3142523 3142524 3121384 3142523 3142523 3142524 3142523 3142523 3142524 3142521 3142523 3142524 3142521 3142523 3142524 FGDR 1"1/2 FGDR 2" Filter 2" Filter DN65 Filter DN80 FGDR 1"1/2 FGDR 2" Filter 2" Filter DN65 Filter DN80 FGDR 1"1/2 FGDR 2" Filter 2" Filter DN80 FGDR 1"1/2 FGDR 2" Filter 2" Filter DN80 FGDR 1"1/2 FGDR 2" Filter 2" FGDR 1"1/2 FGDR 2" Filter 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1" FGDR 1"1/2 FGDR 2" FGDR 1" FGDR 1"1/2 FGDR 2" GAS GOVERNOR AND FILTER CODE TYPE .503 VCS 240 VCS 350 VGD 20.065 VGD 40.080 VCS 240 VCS 350 VGD 20.503 VGD 40.com 43 3/230-400/50Hz MULTICALOR 200.www.1 PR-AB 3/230-400/50Hz MULTICALOR 140 PR-AB 3/230-400/50Hz MULTICALOR 100 PR-AB 3/230-400/50Hz MULTICALOR 70 PR-AB MODEL 414 342 250 200 190 2150 1770 1300 1000 700 OUTPUT [kW] MIN MAX 3142641 3142640 TC TL 3142639 3142638 TC TL 3142637 3142636 TC TL 3142635 3142634 TC TL 3142633 3142632 TL TC BURNER BODY BLAST TUBE CODE Two stage progressive mechanical gas / Two stages light oil OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT SILENCER 500 80 3142075 35 500 500 500 90 500 220 60 3142197 500 500 23 220 3142069 500 500 90 60 3142075 500 500 23 35 500 3142069 500 65 150 500 45 500 500 150 20 500 500 65 45 500 500 80 20 500 35 500 500 35 25 3123860 3142025 3141862 3123860 3124110 3142026 3142025 3141862 3123860 3124110 3142026 3142025 3141862 3123860 3142026 3142025 3141862 3123860 3142026 3142025 3141862 3123860 3142025 3141862 3142024 500 3142025 3141862 25 500 165 40 25 3142024 3142025 500 40 165 3142024 3141862 3142025 3141862 3142024 3142025 25 500 500 3141862 CODE 170 30 15 170 30 15 PRESSURE [mbar] MIN MAX 3142197 3142075 3142069 3142075 3142069 - - - - - - CONNECTION PIPE VCS 240 VCS 350 VGD 20.503 VGD 40.080 VCS 240 VCS 350 VGD 20. ecoflam-burners.com 3/230-400/50Hz MULTICALOR 200.44 www.1 3/230-400/50Hz MULTICALOR 140 3/230-400/50Hz MULTICALOR 100 3/230-400/50Hz MULTICALOR 70 3/230-400/50Hz MULTICALOR 45 MODEL 414 342 400 300 250 190 2150 1770 1300 1000 700 500 OUTPUT [kW] MIN MAX 3142631 3142630 TC TL 3142629 3142628 TC TL 3140438 3140439 TC TL 3140432 3140433 TC TL 3140430 3140431 TC TL 3140428 3140429 TL TC BURNER BODY BLAST TUBE CODE Two stages gas / Two stages light oil .MultiBloc gas train OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT SILENCER 3142075 3142075 3142075 3142075 - - - - - - - - CONNECTION PIPE 100 75 100 75 85 60 360 360 360 360 3141846 3141847 3141846 3141847 3141846 3141847 3141846 3141847 85 60 3141846 3141845 360 3141847 100 50 40 3141845 3141846 360 50 100 3141845 3141847 3141846 3141847 75 360 40 35 27 3141845 3141846 360 35 75 3142022 3141847 3141846 75 360 3141847 27 25 17 3142022 3141846 25 75 3141847 17 360 3141843 3142022 85 50 3141845 360 3141846 30 3141843 3142022 15 85 50 3141845 30 360 3141846 CODE 15 PRESSURE [mbar] MIN MAX MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 410 MB-DLE 415 MB-DLE 420 MB-DLE 410 MB-DLE 415 MB-DLE 420 MB-DLE 407 MB-DLE 410 MB-DLE 412 MB-DLE 415 MB-DLE 407 MB-DLE 410 MB-DLE 412 MB-DLE 415 GAS TRAIN TYPE 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/4 1"1/2 2" 1"1/4 1"1/2 2" 1"1/4 1"1/2 2" 1"1/4 1"1/2 2" 1" 1"1/2 2" 1" 1"1/2 2" 3/4" 1" 1"1/4 1"1/2 3/4" 1" 1"1/4 1"1/2 Ø included included included included included included included included included included included included GAS GOVERNOR AND FILTER .1 3/230-400/50Hz MULTICALOR 170. 1 PR .3/230-400/50Hz MULTICALOR 170.3/230-400/50Hz MODEL 2150 1770 1300 1000 700 OUTPUT [kW] MAX TL TL TL TL TL 100 75 100 75 85 60 85 on request on request on request on request OPT OPT OPT OPT OPT SILENCER 360 360 360 360 3141846 3141847 3141846 3141847 3141846 3141847 3141846 3141845 3141847 3141846 3141847 60 360 100 50 40 3141845 3141846 360 50 100 3141847 40 3141846 3141845 360 3141847 75 35 27 3141845 3141846 75 3141847 35 360 27 3141846 3141847 3142022 3141846 3142022 360 360 3141847 CODE 75 25 17 75 25 17 PRESSURE [mbar] MIN MAX on request BURNER BODY BLAST TUBE CODE Two stage progressive mechanical gas / Two stage progressive mechanical light oil .ecoflam-burners.3/230-400/50Hz MIN MULTICALOR 70 PR .MultiBloc gas train MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 412 MB-DLE 415 MB-DLE 420 MB-DLE 410 MB-DLE 415 MB-DLE 420 MB-DLE 410 MB-DLE 415 MB-DLE 420 GAS TRAIN TYPE 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/4 1"1/2 2" 1"1/4 1"1/2 2" 1"1/4 1"1/2 2" 1"1/4 1"1/2 2" 1" 1"1/2 2" 1" 1"1/2 2" Ø included included included included included included included included included included GAS GOVERNOR AND FILTER .1 PR-AB 3/230-400/50Hz MULTICALOR 170.com 45 414 342 250 200 190 2150 1770 1300 1000 700 OUTPUT [kW] MIN MAX 3142641 3142640 TC TL 3142639 3142638 TC TL 3142637 3142636 TC TL 3142635 3142634 TC TL 3142633 3142632 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT OPT OPT OPT OPT SILENCER 3142075 3142075 3142075 3142075 - - - - - - CONNECTION PIPE 250 300 400 342 414 MULTICALOR 100 PR .1 PR-AB 3/230-400/50Hz MULTICALOR 140 PR-AB 3/230-400/50Hz MULTICALOR 100 PR-AB 3/230-400/50Hz MULTICALOR 70 PR-AB MODEL Two stage progressive mechanical gas / Two stages light oil .3/230-400/50Hz MULTICALOR 200.1 PR .www.Only body 3/230-400/50Hz MULTICALOR 200.3/230-400/50Hz MULTICALOR 140 PR . 065 VGD 20..503 VGD 40.503 VGD 40.. 53) 3/400/50Hz MULTICALOR 600.125 VGD 40. from MULTICALOR 3000.080 VGD 40.100 VGD 40.065 VGD 20.com 1500 1200 875 630 5800 5000 3900 3000 OUTPUT [kW] MIN MAX 3143772 3143771 TC TL 3143770 3143769 TC TL 3143768 3143767 TC TL 3143766 3143765 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT OPT OPT SILENCER 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 CONNECTION PIPE 500 500 500 500 100 180 340 500 60 60 500 500 500 500 75 140 250 50 500 500 500 500 500 45 100 180 340 50 500 500 500 500 500 45 75 140 250 35 500 500 500 500 500 500 500 50 90 170 50 90 170 35 500 30 500 500 500 500 35 55 100 30 500 500 500 500 35 55 100 22 500 22 PRESSURE [mbar] MIN MAX 3142026 3124110 3123860 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3142666 3141869 3142026 3124110 3123860 3141869 3142026 3124110 3123860 3141869 3142026 3124110 3123860 3141869 CODE ! § VGD Siemens: default blank spring.503 VGD 40.46 www.503 VGD 40.503 VGD 40.100 VGD 40.100 VGD 40.080 VGD 40.1 change spring and damping (see pag.080 VGD 40.080 VGD 40.080 VGD 40.125 VGD 40.503 VGD 40. head pressure 0.503 VGD 40.080 VGD 40.100 GAS TRAIN (§) TYPE DN80 DN65 2" DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN125 DN100 DN80 DN65 2" DN100 DN80 DN65 2" DN100 DN80 DN65 2" DN100 Ø 3142088 3124111 3121384 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142206 3142205 3142088 3124111 3121384 3142205 3142088 3124111 3121384 3142205 3142088 3124111 3121384 3142205 Filter DN80 Filter DN65 Filter 2'' Filter DN100 Filter DN80 Filter DN65 Filter 2'' Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2'' Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2'' Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN100 Filter DN80 Filter DN65 Filter 2" Filter DN100 GAS GOVERNOR AND FILTER CODE TYPE .503 VGD 40.100 VGD 40.ecoflam-burners.065 VGD 20.1 PR 3/400/50Hz MULTICALOR 300.100 VGD 40.065 VGD 20.065 VGD 20.1 PR 3/400/50Hz MULTICALOR 400.065 VGD 20.1 PR MODEL Two stage progressive mechanical gas / Two stage progressive mechanical light oil VGD 40.125 VGD 40.125 VGD 40.1 PR 3/400/50Hz MULTICALOR 500.100 VGD 40.22 mbar.080 VGD 40.065 VGD 20.065 VGD 20.080 VGD 40.100 VGD 40. 125 GAS TRAIN (§) TYPE DN100 DN125 DN100 DN80 DN125 DN100 DN80 DN125 DN100 DN80 DN65 DN125 DN100 DN80 DN65 DN125 DN100 DN80 DN65 DN125 Ø 3142205 3142206 3142205 3142088 3142206 3142205 3142088 3142206 3142205 3142088 3124111 3142206 3142205 3142088 3124111 3142206 3142205 3142088 3124111 3142206 Filter DN100 Filter DN125 Filter DN100 Filter DN80 Filter DN125 Filter DN100 Filter DN80 Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter DN125 Filter DN100 Filter DN80 Filter DN65 Filter DN125 GAS GOVERNOR AND FILTER CODE TYPE .125 VGD 40.100 VGD 40.080 VGD 40.1 PR MODEL VGD 40.100 VGD 40.1 PR 3/400/50Hz MULTICALOR 800.065 VGD 40.com 47 4000 3690 2700 2500 2000 1500 17000 15000 13000 10500 8500 7500 OUTPUT [kW] MIN MAX TC TC TC TC TC TC 3143778 3143777 3143776 3143775 3143774 3143773 BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT SILENCER 3142422+ 3142425 3142422 330 210 230 450 150 3142422+ 3142425 3142422 3142424 230 420 175 3142422+ 3142425 3142422 3142424 165 290 550 115 3142422+ 3142425 3142422 3142424 3142423 110 210 410 85 3142422+ 3142425 3142422 3142424 3142423 75 140 280 500 500 500 500 500 500 60 3142422+ 3142425 3142422 3142424 3142423 PRESSURE [mbar] MIN MAX CONNECTION PIPE 3141869 3142666 3141869 3142026 3142666 3141869 3142026 3142666 3141869 3142026 3124110 3142666 3141869 3142026 3124110 3142666 3141869 3142026 3124110 3142666 CODE see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page MULTICALOR .1 PR 3/400/50Hz MULTICALOR 700.065 VGD 40.1 PR 3/400/50Hz MULTICALOR 1500.22 mbar.1 PR 3/400/50Hz MULTICALOR 1200.100 VGD 40.125 VGD 40. head pressure 0..100 VGD 40.125 VGD 40.125 VGD 40. from MULTICALOR 3000..080 VGD 40.100 VGD 40. 53) 3/400/50Hz MULTICALOR 1800.125 VGD 40.ecoflam-burners. Silencer Tightness control Modulation kit Probe LPG kit Additional gas accessories Automatic fuel changeover kit Oil pumping unit DESCRIPTION KIT .ACCESSORIES ! § VGD Siemens: default blank spring.065 VGD 40.www.DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.080 VGD 40.080 VGD 40.1 change spring and damping (see pag.080 VGD 40.1 PR 3/400/50Hz MULTICALOR 1000.100 VGD 40. .1 and 1500.. Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation. from MULTIFLAM 300.) MULTIFLAM range is available in the following versions and is delivered in a modular system of boxes: • PAB: 2 stages gas and heavy oil / soft start heavy oil • PR: 2 stage progressive mechanical gas .Max visc. 50°E at 50°C DUAL FUEL BURNERS (GAS/HEAVY OIL) .. Tightness control device must be included over 1200 kW according to EN676.... Electrical pre-heater preassembled into the burner body.1 . 53)..... GT: Gas train separate → EN676 or Export configuration GTCP: Connection pipe between burner and gas train starting from model 170. ! three-phase. If main supply is three-phase 230V/50Hz see • CV: Continuous ventilation version • OEM and special application version only on request • KITSWIRL: Swirl system for flame customized in our Flexshop AVAILABLE CONFIGURATIONS ON REQUEST • KIT automatic fuel changeover • PID modulating KIT and probe • KIT Wieland plugs • Antivibration coupling and ball valve • Silencer (starting from platform 260) KIT .1 change spring and damping (see pag. Standard version running on manual fuel selection mode and on request kit for automatic fuel changeover.ecoflam-burners. BBCH: Burner body with combustion head → TC short head and TL long head in D version for heavy oil with max visc 50°E at 50°C.. • KITTC-.1.: Tightness control kit to be included over 1200 kW according to EN676 KITPRES..1 and with hinge flange for models 200. All burners body are delivered with sliding bar system up to model 1200. ball valve.: Maximum pressure switch KIT & ACS can be added according to local rules installations (silencer. • KITPRES.heavy oil MULTIFLAM . EN676 configuration: • double gas valves with actuators and regulator VGD Siemens§ + gas filter.1 FGDR: Gas governor and filter for double solenoid valves VCS Kromschröder FILTER for double gas valves VGD Siemens KITTC-. head pressure 0. Maximum pressure switch as option or in compliance with local safety regulations. antivibration coupling.1800. The automatic changeover system can be triggered by a gas pressure switch or by a timer.22 mbar.48 www.com All burners 230-400V/50Hz are factory tested at 400V/50Hz instruction manual for adjustments and modifications.ACS (see dedicated pages) § VGD Siemens: default blank spring. 065 VGD 40.503 VGD 40.080 VGD 40.080 VGD 20.1 PR 3/400/50Hz MULTIFLAM 300.065 VGD 40. from MULTIFLAM 3000..065 VGD 40.1 PR MODEL Two stage progressive mechanical gas / Two stage progressive mechanical heavy oil . 50°E at 50°C VGD 20.100 VGD 20.503 VGD 40.100 GAS TRAIN TYPE VGD 20.50°E fuel viscosity at 50°C DUAL FUEL BURNERS (GAS/HEAVY OIL) MULTIFLAM ..100 VGD 20.22 mbar.503 VGD 40.ecoflam-burners.503 VGD 40.www. 53) 3/400/50Hz MULTIFLAM 400.065 VGD 40.1 change spring and damping (see pag.065 VGD 40.503 VGD 40.080 VGD 40.1 MODEL Two stages gas / Two stages heavy oil .100 VGD 20.50°E fuel viscosity at 50°C 3/230-400/50Hz MULTIFLAM 200.080 GAS TRAIN TYPE 2" DN65 DN80 DN100 2" DN65 DN80 DN100 2" DN65 DN80 DN100 2" DN65 DN80 DN100 Ø 2" DN65 DN80 2" DN65 DN80 Ø Filter 2" Filter DN65 Filter DN80 Filter 2" Filter DN65 Filter DN80 3121384 3124111 3142088 3142205 3121384 3124111 3142088 3142205 3121384 3124111 3142088 3142205 3121384 3124111 3142088 3142205 Filter 2" Filter DN65 Filter DN80 Filter DN100 Filter 2" Filter DN65 Filter DN80 Filter DN100 Filter 2" Filter DN65 Filter DN80 Filter DN100 Filter 2" Filter DN65 Filter DN80 Filter DN100 GAS GOVERNOR AND FILTER CODE TYPE 3121384 3124111 3142088 3121384 3124111 3142088 GAS GOVERNOR AND FILTER CODE TYPE .080 VGD 40.503 VGD 40.Max visc.080 VGD 40.065 VGD 40.com 49 414 2150 OUTPUT [kW] MIN MAX TL TC 3142670 3142669 BURNER BODY BLAST TUBE CODE OPT OPT SILENCER 55 100 3142935 3143080 35 100 3143080 - 55 35 500 500 500 500 500 500 PRESSURE [mbar] MIN MAX 3142935 - CONNECTION PIPE 875 630 3900 3000 OUTPUT [kW] MIN MAX 3143782 3143781 TC TL 3143780 3143779 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT SILENCER 90 170 3142935 3143080 170 3143080 50 90 3142935 - 50 - 30 30 3142073 3142073 55 100 3142935 3143080 35 100 3143080 - 55 3142935 22 35 - 3142073 22 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 PRESSURE [mbar] MIN MAX 3142073 CONNECTION PIPE 3123860 3124110 3142026 3141869 3123860 3124110 3142026 3141869 3123860 3124110 3142026 3141869 3123860 3124110 3142026 3141869 CODE 3123860 3124110 3142026 3123860 3124110 3142026 CODE ! § VGD Siemens: default blank spring. head pressure 0. head pressure 0.065 VGD 40.100 VGD 40.080 VGD 40.065 VGD 40.080 VGD 40.50 www.503 VGD 40.080 VGD 40.503 VGD 40..22 mbar.1 PR MODEL VGD 20.125 GAS TRAIN TYPE 2" DN65 DN80 DN100 DN125 2" DN65 DN80 DN100 DN125 2" DN65 DN80 DN100 DN125 2" DN65 DN80 DN100 DN125 Ø 3121384 3124111 3142088 3142205 3142206 3121384 3124111 3142088 3142205 3142206 3121384 3124111 3142088 3142205 3142206 3121384 3124111 3142088 3142205 3142206 Filter 2'' Filter DN65 Filter DN80 Filter DN100 Filter DN125 Filter 2'' Filter DN65 Filter DN80 Filter DN100 Filter DN125 Filter 2'' Filter DN65 Filter DN80 Filter DN100 Filter DN125 Filter 2'' Filter DN65 Filter DN80 Filter DN100 Filter DN125 GAS GOVERNOR AND FILTER CODE TYPE .125 VGD 20.ecoflam-burners.100 VGD 40.080 VGD 40.com 5800 5000 3143786 3143785 TC TL 3143784 3143783 TL TC BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT SILENCER 180 340 3142935 3143080 60 3142073 100 50 3143105 - 340 3143080 180 60 3142073 3142935 50 3143105 100 250 3143080 - 140 3142935 45 3142073 75 35 3143105 - 250 140 3142935 3143080 75 45 3142073 - 35 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 PRESSURE [mbar] MIN MAX 3143105 CONNECTION PIPE 3123860 3124110 3142026 3141869 3142666 3123860 3124110 3142026 3141869 3142666 3123860 3124110 3142026 3141869 3142666 3123860 3124110 3142026 3141869 3142666 CODE Silencer Tightness control Modulation kit Probe LPG kit Additional gas accessories Automatic fuel changeover kit Oil heating pumping unit DESCRIPTION KIT .065 VGD 40.100 VGD 40.100 VGD 40. from MULTIFLAM 3000.1 change spring and damping (see pag.065 VGD 40. 53) 3/400/50Hz 1500 MULTIFLAM 600.1 PR 3/400/50Hz 1200 OUTPUT [kW] MIN MAX MULTIFLAM 500.503 VGD 40.ACCESSORIES see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page ! § VGD Siemens: default blank spring.125 VGD 20.125 VGD 20.503 VGD 40.. 065 410 VGD 40..125 175 230 VGD 40.125 150 230 VGD 40.150 125 500 VGD 40.100 165 290 VGD 40.100 VGD 40.125 GAS TRAIN (§) TYPE 60 PRESSURE [mbar] MIN MAX ! § VGD Siemens: default blank spring.1 change spring and damping (see pag.065 550 VGD 40.1 PR 3/400/50Hz MULTIFLAM 1000.100 110 210 VGD 40. 53) 3/400/50Hz MULTIFLAM 1800.com 51 4000 3690 2700 2500 2000 1500 17000 15000 13000 10500 8500 7500 OUTPUT [kW] MIN MAX TC TC TC TC TC TC - - - - - - BURNER BODY BLAST TUBE CODE OPT OPT OPT OPT OPT OPT SILENCER 330 500 MULTIFLAM ..080 VGD 40.www. from MULTIFLAM 3000.080 450 VGD 40.1 PR MODEL Two stage progressive mechanical gas / Two stage progressive mechanical heavy oil .080 VGD 40.100 VGD 40.1 PR 3/400/50Hz MULTIFLAM 1500. VGD 40.ecoflam-burners. head pressure 0.080 420 VGD 40.100 75 500 VGD 40.100 VGD 40.22 mbar.125 VGD 40.150 160 500 VGD 40.50°E fuel viscosity at 50°C DN100 DN125 DN150 DN80 DN100 DN125 DN150 DN80 DN100 DN125 DN150 DN65 DN80 DN100 DN125 DN65 DN80 DN100 DN125 DN65 DN80 DN100 DN125 Ø Filter DN100 Filter DN125 Filter DN150 Filter DN80 Filter DN100 Filter DN125 Filter DN150 Filter DN80 Filter DN100 Filter DN125 Filter DN150 Filter DN65 Filter DN80 Filter DN100 Filter DN125 Filter DN65 Filter DN80 Filter DN100 Filter DN125 Filter DN65 Filter DN80 Filter DN100 Filter DN125 GAS GOVERNOR AND FILTER .1 PR 3/400/50Hz MULTIFLAM 800.125 115 500 VGD 40.1 PR 3/400/50Hz MULTIFLAM 1200.150 175 210 VGD 40.125 85 500 VGD 40.1 PR 3/400/50Hz MULTIFLAM 700.080 280 140 VGD 40.065 VGD 40.DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application. 1" GT-K1-VCS240-RP40-MAXGAS170-250 RP 40 .1/2" GT-B1-EG12L-RP15-MAXGAS40-120 Ø RP 50 .3/4" RP 25 .1" RP 32 .1" GT-D1-MBDLE410-RP25-MAXGAS170-250 GT-D2-MBZRDLE410-RP25-MAXGAS170-250 RP 20 .1"1/2 GT-D2-MBDLE415-RP40-MAXGAS350-500 GT-K1-VCS125-RP25-MAXGAS170-250 RP 32 .ecoflam-burners.3/4" RP 15 . regulator and min pressure switch.1/2" GT-D1-MBC65DLE-RP15-MAXGAS40-120 DESIGNATION Ø DESIGNATION DESCRIPTION MB-DLE MultiBloc Dungs MAX GAS 350-500 DESCRIPTION MB-ZRDLE MultiBloc Dungs MAX GAS 40-250 DESCRIPTION MB-DLE MultiBloc Dungs MAX GAS 40-250 DESCRIPTION Double solenoid valves VCS Kromschröder and min pressure switch + ACS gas governor & filter Export EN676 + FGDR CONFIGURATION WARNING: EN676 compulsory kit and accessories in order to comply to the safety regulations.1"1/2 VCS Kromschröder MAX GAS 350-500 RP 25 .1/2" GT-D1-MBDLE403-RP15-MAXGAS40-120 GT-D2-MBZRDLE405-RP20-MAXGAS40-120 RP 20 .1"1/2 GT-K1-VAS125-RP25-MAXGAS170-250 GT-K1-VAS240-RP40-MAXGAS170-250 RP 15 .1" DESCRIPTION Ø DESIGNATION GT-K2-VCS125-RP25-MAXGAS350-500/MULTI DESCRIPTION CONFIGURATION RP 40 .52 www. Additional accessories and kits shall be installed by the installer in accordance to the local safety regulations and codes of practise. MultiBloc Dungs: compact double solenoid valve with integrated filter.1"1/4 GT-D2-MBZRDLE412-RP32-MAXGAS170-250 RP 40 .1" GT-D2-MBDLE410-RP25-MAXGAS350-500 Ø RP 20 .3/4" GT-D1-MBDLE405-RP20-MAXGAS40-120 RP 20 .3/4" DESIGNATION Ø DESIGNATION RP 40 .1"1/2 GT-D2-MBZRDLE415-RP40-MAXGAS170-250 GT-D2-MBDLE407-RP20-MAXGAS350-500 RP 32 .1"1/4 GT-D1-MBDLE412-RP32-MAXGAS170-250 RP 20 .1/2" GT-B1-E6GSRP-RP15-MAXGAS40-120 RP 15 .2" GT-K2-VCS350-RP50-MAXGAS350-500/MULTI GT-D1-GBLE055-RP15-MAXGAS40-120 RP 40 .1/2" RP 15 .3/4" GT-D1-MBC120DLE-RP20-MAXGAS40-120 Ø RP 15 .1"1/2 GT-K2-VCS240-RP40-MAXGAS350-500/MULTI DESIGNATION RP 25 .1" RP 40 .com Export gas trains MAX GAS 40-250 Only Export (not EN676) RP 25 .3/4" GT-D1-MBDLE407-RP20-MAXGAS170-250 GT-D2-MBZRDLE407-RP20-MAXGAS170-250 RP 20 .1"1/4 GT-D2-MBDLE412-RP32-MAXGAS350-500 VCS Kromschröder MAX GAS 170-250 RP 25 . EN676 CONFIGURATION GAS TRAIN: MAX GAS CODE 3142816 3142815 3141887 3141888 3142027 CODE 3142376 3142375 3142374 CODE 3142251 3141906 CODE 3142296 3142295 3142665 3142392 CODE 3123879 3141901 3123962 3123961 3123960 CODE 3123969 3141899 3123947 3123525 3123560 3123944 3141886 3141885 .1"1/2 GT-D1-MBDLE415-RP40-MAXGAS170-250 RP 25 . .. regulator and min pressure switch.1 MULTIFLAM 300.2" 1/2 DN 80 .ecoflam-burners.. MB-DLE MULTIBLOC DUNGS SPRING DAMPING THROTTLE Gas trains include ACTUATORS DESCRIPTION GTCP RP50-DN65 platform 260 GTCP RP50 platform 280 GTCP RP50 platform 280/320/380 GTCP RP50 BLU 1500 with MB415-420 GTCP RP50 adaptor for MULTIFLAM GTCP DN65 platform 260/280/320 GTCP DN80 platform 260/280/320 GTCP DN65 platform 380 GTCP DN80 platform 380 GTCP reducer from DN80 to DN65 for MULTIFLAM GTCP reducer from DN100 to DN80 platform 320/380 GTCP reducer from DN125 to DN80 platform 320/380 GTCP DN125 platform 380 GTCP DN65 platform 630 GTCP DN80 platform 630/710 GTCP DN100 platform 630/710 GTCP DN125 platform 630/710 Both codes necessary for gas train DN125 GTCP reducer from DN125 to DN100 DESIGNATION GT-D2-MBDLE407-RP20-BLU/MULTI GT-D2-MBDLE410-RP25-BLU/MULTI GT-D2-MBDLE412-RP32-BLU/MULTI GT-D2-MBDLE415-RP40-BLU/MULTI GT-D2-MBDLE420-RP50-BLU/MULTI DESIGNATION GT-K2-VCS125-RP25-BLU/MULTI GT-K2-VCS240-RP40-BLU/MULTI GT-K2-VCS350-RP50-BLU/MULTI DESIGNATION GT-S2-VGD20-RP50-BLU/MULTI GT-S2-VGD40-DN65-BLU/MULTI GT-S2-VGD40-DN80-BLU/MULTI GT-S2-VGD40-DN100-BLU/MULTI GT-S2-VGD40-DN100+VDK-BLU/MULTI GT-S2-VGD40-DN125-BLU/MULTI GT-S2-VGD40-DN125+VDK-BLU/MULTI Yellow setpoint spring for SKP25.1" RP 40 .1 change spring and damping Export / EN676 + FGDR Double gas valves with actuators and regulator VGD Siemens and min pressure switch + ACS gas filter.www. GAS TRAIN AND GTCP: BLU .4" DN 100 ..MULTICALOR .2" Ø RP 50 ..MULTICALOR 170.4" + VDK DN 125 .1.5" DN 125 .com 53 WARNING: from BLU 1700.1 .. Default blank spring: head pressure 0.120 mbar Ø RP 20 . Damping throttle for SKP25.MULTIFLAM DESIGNATION GTCP-RP50-DN65-260 GTCP-RP50-280 GTCP-RP50-320/380 GTCP-RP50-BLU1500-MB415-420 GTCP-RP50-ADAPTOR-MULTIFLAM GTCP-DN65-260/280/320 GTCP-DN80-260/280/320 GTCP-DN65-380 GTCP-DN80-380 GTCP-REDUCERDN80TODN65 GTCP-REDUCERDN100TODN80 GTCP-REDUCERDN125TODN80 GTCP-DN125-380 GTCP-DN65-630 GTCP-DN80-630/710 GTCP-DN100-630/710 GTCP-DN125-630/710 GTCP-REDUCERDN125TODN100 Head pressure: 15.2" DN 65 .3/4" RP 25 .1"1/2 RP 50 .3" DN 100 .MULTICALOR 300. the corresponding connection pipe must be ordered (GTCP size and fitting depend on the burner and the gas train selected) GAS TRAIN CONNECTION PIPE WARNING: from BLU 3000.22 mbar VGD SIEMENS Export / EN676 + FGDR Double solenoid valves VCS Kromschröder and min pressure switch + ACS gas governor & filter VCS KROMSCHRÖDER EN676 MultiBloc Dungs: compact double solenoid valve with integrated filter.2" Ø RP 25 .1 . in order to fit the gas train..1"1/4 RP 40 .1 MULTIFLAM 200.1"1/2 RP 50 ..1" RP 32 .5" + VDK CODE 3141842 3142074 3142075 3142076 3143080 3142197 3142069 3142071 3142070 3142935 3142073 3143105 3142198 3142423 3142424 3142422 3142422 3142425 CODE 3141843 3142022 3141845 3141846 3141847 CODE 3142024 3142025 3141862 CODE 3123860 3124110 3142026 3141869 3141871 3142666 3141872 3142204 3142207 . 1/2" * RP 20 .3" FS1B DN 100 .3/4" RP 25 .1" * RP 32 .2" * FS1B RP 50 .3" DN 100 .2" FS1B DN 65 .5" DESCRIPTION CODE 3141957 3142045 3142046 3141954 3121384 3124111 3142088 3142205 3142206 DESCRIPTION .4" FS1B DN 125 .2" DN 65 .com 500 mbar 500 mbar 500 mbar 500 mbar 500 mbar 500 mbar 1 bar 1 bar 1 bar 1 bar 1 bar RP 15 .2" DN 65 .1"1/2 * RP 50 .1/2" RP 20 .2"1/2 DN 80 .4" DN 125 .4" DN 125 .ecoflam-burners.1" RP 40 .3" DN 100 .5" DESCRIPTION CODE RP 15 .1"1/2 RP 50 .2"1/2 DN 80 .2" DN 65 .2"1/2 DN 80 .1"1/4 RP 40 .1" RP 32 .3" DN 100 .1/2" RP 20 .1"1/2 RP 50 .1"1/4 * RP 40 .1/2" RP 20 .5" SPRING for GAS GOVERNOR and FILTER FGDR GAS PRESSURE RANGE 5÷15 mbar 10÷30 mbar 25÷80 mbar 70÷160 mbar 150÷280 mbar 270÷350 mbar 5÷15 mbar 10÷25 mbar 20÷70 mbar 65÷130 mbar 120÷250 mbar 240÷350 mbar 5÷15 mbar 10÷35 mbar 30÷80 mbar 70÷220 mbar 210÷350 mbar DESCRIPTION Green spring FGDR 15-20-25 Neutral spring FGDR 15-20-25 Violet spring FGDR 15-20-25 Brown spring FGDR 15-20-25 Blue spring FGDR 15-20-25 White spring FGDR 15-20-25 Green spring FGDR 32-40 Neutral spring FGDR 32-40 Violet spring FGDR 32-40 Brown spring FGDR 32-40 White spring FGDR 32-40 Black spring FGDR 32-40 Green spring FGDR 50 Neutral spring FGDR 50 Violet spring FGDR 50 Brown spring FGDR 50 Blue spring FGDR 50 * Default spring is neutral for outlet pressure range 10-30 mbar GAS GOVERNOR and FILTER FGDR MAX GAS PRESSURE DESCRIPTION KIT AND ACCESSORIES FOR GAS 3142563 3142562 3142561 3142560 3142559 3142558 3142557 3142556 3142555 3142554 3142553 3142552 3142551 3142550 3142549 3142548 3142547 CODE on request on request 3142538 3141983 3142051 3142524 3142523 3142522 3142521 3142520 3142519 CODE MANUAL VALVE ANTIVIBRATION COUPLING GAS FILTER CODE 3142000 3142254 3121430 3142253 3142101 3142102 3142062 3143730 3141997 3141998 RP 15 .2"1/2 FS1B DN 80 .54 www.1"1/2 RP 50 .5" 3122321 3122322 3122323 3122324 3122325 3122326 3142060 3122328 3122329 3142061 RP 15 .1"1/4 RP 40 .1" RP 32 .3/4" RP 25 .4" DN 125 .3/4" RP 25 .3/4" * RP 25 . 1 KITPRES50 KITPRES150 DESCRIPTION Gas manometer Gas manometer Gas manometer Push button 1/4" Push button 1/2" DESIGNATION KITLPG-MAXGAS40-120 KITADAPTOR-MAXGAS40-120 KITLPG-MAXGAS170-250 KITADAPTOR-MAXGAS170-250 KITLPG-MAXGAS350-500 KITLPG-BLU500.1-1200.1 BLU 1000.5÷50 mbar GAS PRESSURE CODE 3142667 3124489 3124488 3124487 3142431 3122300 3122302 3122299 3122301 CODE 3142057 3142058 3142054 3142055 3142056 CODE 3142033 3141921 CODE 3142754 3142314 3141922 3142688 3122305 3142190 3122303 3142238 3141929 .1 Other model kit on request OUTPUT RANGE DESIGNATION Kit adaptor for kit VPS pilot gas train DESIGNATION DESCRIPTION KIT AND ACCESSORIES FOR GAS 30÷150 mbar 2.1-2000.com 55 KIT LPG / KIT GN MANOMETER + PUSH BUTTON MAXIMUM GAS PRESSURE SWITCH TIGHTNESS CONTROL KITTC-VPS504-VCS KITTC-LPGVPS504-VCS KITTC-VPS504-MB-VGDDN65-80 KITTC-LPGVPS504-MB-VGDDN65-80 KITTC-VPS504-VGD20503 KITTC-LPGVPS504-VGD20503 KITTC-VDK200 KITTC-LDU11 Kit tightness control VPS504 for VCS gas valve Kit tightness control VPS504 LPG for VCS gas valve Kit tightness control VPS504 for MB and VGD65-80 valve Kit tightness control VPS504 LPG for MB and VGD65-80 valve Kit tightness control VPS504 for VGD20503 valve Kit tightness control VPS504 LPG for VGD20503 valve Kit tightness control VDK for VGD100-125 Kit tightness control LDU 100÷5800 kW 7000÷25000 kW GAS PRESSURE 0…60 mbar 1/2" 0…250 mbar 1/4" 0…1000 mbar 1/4" Diameter 1/4" Diameter 1/2" BURNER MAX GAS 40-120 MAX GAS 40-120 MAX GAS 170-250 MAX GAS 170-250 MAX GAS 350-500 BLU 500.ecoflam-burners.1-1500.1-1500.1 KITLPG-BLU700.1 KITLPG-BLU1000.1 BLU 1700.www.1 BLU 700.1-2000.1 KITLPG-BLU1700. .30 and MAX P 25 AB HS KITBIODIESEL-PUMP-AS47 DIAGNOSTIC TOOL CODE 3142931 3833018 PC interface for BCU CODE 3141932 3142034 3142037 CODE 3141965 3142092 CODE 3124103 3141917 CODE 3142021 E-BCU Diagnostic tool for 1 stage BCU DESCRIPTION DIAGNOSTIC TOOL FOR THERMOWATT CONTROL SWIRL SYSTEM HEAVY OIL HEATING AND PUMPING UNIT LIGHT OIL PUMPING UNIT SEPARATE PRE-HEATER UNIT KIT WIELAND PLUGS MAGNETIC + SELFCLEANING FILTER KIT BIODIESEL DESCRIPTION DESIGNATION Standard version running on manual fuel selection mode and with the automatic changeover the system change fuel triggered by a gas pressure switch or by a timer KIT FOR AUTOMATIC FUEL SWITCH GAS/OIL KIT AND ACCESSORIES FOR OIL . The system is available for different fuel burner blast tubes DESCRIPTION “OIL RING” can be design and delivered assembled on skid or offered as single component DESCRIPTION Separate service tanks and pump units DESCRIPTION From OILFLAM 300..MULTICALOR (PR versions) KITWP-BLU/MULTICALOR-PR/MD MAIOR 45 .56 www.1 (PAB versions) DESCRIPTION DESIGNATION KITWP-BLU500.1PAB BLU 500.300.1-2000.ecoflam-burners.2000.com KIT-AUTOMATICFUELSWITCH-MULTI DESIGNATION Dual fuel burners: MULTICALOR and MULTIFLAM DESCRIPTION Swirls for blast tube that can reduce flame lenght up to 10-50% depending on fuel. backpressure and shape of combustion chamber.1PAB MAXFLAM range OILFLAM range DESCRIPTION DESIGNATION KITOIL250KG-MAGNETIC+SELFCLEANING-FILTER MAX P 12-15 AB HS KITBIODIESEL-PUMP-AT2/AT3 KITOIL50KG-MAGNETIC+SELFCLEANING-FILTER MAX 1.1 .1 pre-heater can be supplied separately with extra cost DESCRIPTION BLU .1 KITWP-MAIOR35-300. 1 .1 .1 .1 .1 .1 .1 MULTICALOR 170.600.1 MULTICALOR 700.1 MAIOR 150.200.1 DUAL FUEL (GAS/HEAVY OIL) 3122314 3122320 3122319 3122318 3122316 DESIGNATION PROBE-WATER130C DESCRIPTION CODE CODE 3143713 DESIGNATION KITMD-RWF50 Water probe up to 0÷130° С Kit for progressive version PLATFORM MAIOR 1500.200.1200.1 MULTICALOR 1500.1 MULTICALOR 45 .4000.200.1 MAIOR 300.1 .1800.1 MAIOR 45 .1 PLATFORM KITSIL-260 SILENCER MATCHING PROBE FOR FULL MD VERSION MODULATING PID CONTROLLER LOAD CONTROLLER AND PROBES .12000.1 .600.1 .6000.400.140 DUAL FUEL (GAS/LIGHT OIL) PROBE-HOTAIR-LIQUID450C Hot air or liquid probe up to 0÷450° С HEAVY OIL PROBE-STEAM16BAR PROBE-STEAM40BAR Steam probe 0÷16 bar Steam probe 0÷40 bar PROBE-STEAM4BAR PROBE-STEAM10BAR Steam probe 0÷4 bar Steam probe 0÷10 bar 3124100 PROBE-STEAM2BAR Steam probe 0÷2 bar MULTIFLAM 1500.1 MULTIFLAM 700.1 .600.1 .1 OILFLAM 170.1 MULTIFLAM 500.400.ecoflam-burners.1 .120 KITSIL-710 BLU 3000.1 OILFLAM 700.1 DESCRIPTION 3122317 CODE 3141911 3122298 3141913 3141914 3142276 3142668 KITSIL-260 KITSIL-280 KITSIL-320 KITSIL-380 KITSIL-630 KITSIL-710 OILFLAM 1500.1 .1200.1 .200.1 .1 KITSIL-280 KITSIL-380 GAS BLU 700.1800.1 OILFLAM 50.1 OILFLAM 300.1 MULTIFLAM 170.1 .1 .1 .600.18000.400.400.1 MULTIFLAM 300.1 .1 KITSIL-320 BLU 1500.120.1 MULTIFLAM 50.1 .1800.1 BLU 5000.1 OILFLAM 500.1200.1 .1200.1 .1 .1 .1 .1 MULTICALOR 500.1 MULTICALOR 300.1 .1 BLU 15000.www.1 KITSIL-630 MAIOR 500.1 .1 BLU 7000.1 .com 57 LIGHT OIL Option available starting from platform 260 Separate ventilator silencer / Sound proof platform on request DUOBLOCK MAIOR 700.1200.2000.1800.120. ......BURNER SELECTION FORM SECTION 1 ........COUNTRY REFERENCE SALES PERSON REQUEST DATE INSTALLATION LOCATION SEGMENT heating heating OEM bakery dryers projects other industry SECTION 2 .. Lower calorific value [kcal/kg] Lower calorific value [kcal/m3] Lower calorific value [kcal/m3] Viscosity at 50°C [°E] Supply pressure [mbar] Supply pressure [mbar] Required flowrate [kg/h] Required flowrate [m3/h] Required flowrate [m3/h] www........com .....GENERAL INFORMATION CUSTOMER . year diathermic boiler incinerator APPLICATION TYPE dryer / hot air generator oven steam (saturated) Steam capacity [TPH] Required steam pressure bar hot water Steam temperature [°C] salt / oil Medium temperature [°C] Medium inlet temperature [°C] steam (superheated) HEAT TRANSFER MEDIUM STEAM OTHER others POWER REQUIREMENT BOILER LOCATION Boiler Output [kW] Boiler Input [kW] Boiler efficiency [%] Burner power [kW] Backpressure [mbar] 1 kW = 860 kcal/h outdoor indoor HEIGHT ABOVE SEA LEVEL [m] DIMENSIONS [mm] Inner diameter Furnace position FURNACE CHAMBER DATA horizontal Length top-down Return chamber length bottom-up Length Height ELECTRICAL SUPPLY DATA Width min [mm] Required blast tube Lenght max [mm] Voltage single phase 110 V 220 V 230 V 240 V Voltage three phase 220 V 380 V 400 V 415 V Frequency 50 Hz 60 Hz Required IP factor IP40 IP54 440 V 460 V 480 V other: SECTION 3 .. 58 BIOGAS-TOWNGAS (Max H2S<0..FUEL INFORMATION LIGHT OIL ..........1%) Type: ……………………….. Type: ………………………………………..HEAVY OIL GAS / LPG Type: …………………………...ecoflam-burners...BOILER INFORMATION BOILER TYPE three pass boiler Boiler brand reverse flame boiler Boiler model water tube boiler Boiler manuf... com 59 ..110 mg/kWh FUEL 1: FUEL 2: FUEL 3: <120 mg/kWh Class 3 0.60 mg/kWh Automatic fuel changeover Other requirements: specify SECTION 5 .100 mg/kWh FUEL SUPPLY single fuel two fuels three fuels CONTROL TYPE 1 stage 2 stages 2 stage progressive mechanical modulating mechanical with PID modulating electronic OPTIONS FOR ELECTRONIC VERSION inverter (modulating electronic only) O2 trim (modulating electronic only) CO trim (modulating electronic only) ELECTRICAL CONFIGURATION standard electrical panel loosen form with derivative panel separate switch cabinet Light Oil: EN267 1:8 1:10 <250 mg/kWh <185 mg/kWh Class 1 Class 2 0..BURNER BURNER TYPE BURNER POWER Duoblock Monoblock [°C] (Max 200°C) [mbar] [m3/h] [mbar] refer to the field "burner power" in the section "power requirement" mechanical: electronic: NOMINAL TURNDOWN RATIO EMISSIONS LEVEL Combustion air temperature Heat exchanger pressure losses flowrate: Current fan (if existing): pressure: NOx: CO: Gas: 1:3 1:6 electronic with inverter: electronic with inverter: <120 mg/kWh <80 mg/kWh Class 2 Class 3 EN676 0..SECTION 4 ..ecoflam-burners.ADDITIONAL INFORMATION www..GAS TRAIN CONFIGURATION Gas governor and filter Gas train type Dungs MultiBloc Siemens VGD Kromschröder VCS Honeywell FGDR Max 500 mbar FS1B Max 1 bar ST4B Max 4 bar Filter Max 1 bar Tightness control VPS VDK LDU Electronic Maximum pressure switch KITPRES50 up to 6 MW KITPRES150 up to 25 MW Other requirements: specify NOTES .. Via A. .HEAD OFFICE: Via Roma.com Email: export@ecoflam-burners. without prior notice.p.: +39 0423 719500 Fax: +39 0423 719580 Web: www.CF 01026940427 Version 1. reserves the right to make any adjustments. 64 31023 Resana (TV) REGISTERED OFFICE: Viale A. 45 . which is considered necessary or useful to its products. Merloni. Merloni. without affecting their main features.A.ecoflam-burners. 45 60044 Fabriano (AN) Tel.60044 Fabriano (AN) .15/07/2014 ECOFLAM Bruciatori S. .com Company subject to the direction and coordination of Ariston Thermo SpA.5 .
Copyright © 2024 DOKUMEN.SITE Inc.