DVP20SX211R



Comments



Description

2011-04-125011696701-SX21 .. .. DVP-1150070-02 DO NOT connect the AC main circuit power supply to any of the input/output terminals. This is an OPEN TYPE PLC. For details on the optional peripheral. including digital input/output (max. analog modules (A/D. in order to prevent hazard to users or damage on the PLC. The PLC should be kept in an enclosure away from airborne dust. offering various instructions and is with 16k steps program memory. able to connect with all Slim series extension models. it is equipped with protective methods such as some special tools or keys to open the enclosure.………………………………………………………………… ENGLISH …………………………………………………………………… Thank you for choosing Delta DVP-SX2.5A@24VDC 2. Also. electric shock risk and vibration. 7. Product Profile 1 Left-side module connection port 3 POWER/RUN/ERROR/USB indicator 10 Direct fastening hole 4 COM1 communication indicator (RS-232) V0+ I0+ VI0V1+ I1+ VI1V2+ 5 COM2 communication I2+ VI2V3+ I3+ VI3- indicator (RS-485) 6 I/O indicator 7 USB port 8 VR0/VR1 9 DIN rail clip 11 I/O terminal FE VO0 IO0 VO1 IO1 AG 12 RUN/STOP switch 13 COM1 port (RS-232) [ Figure 1 ] 2 Nameplate 14 COM2 port 16 3PIN removable terminal (RS-485) (standard component) 18 I/O module positioning hole 19 I/O module connection port 20 Mounting slot (35mm) 15 Power input 17 Power input connection port cable (standard component) 21 I/O module fastening clip [ Figure 2 ] Electrical Specifications Model Item DVP20SX211R DVP20SX211T DVP20SX211S 24VDC (-15% ~ 20%) Power supply voltage (with counter-connection protection on the polarity of DC input power) DVPPS01(PS02): input 100-240VAC.5A/30VDC. make sure the PLC is properly grounded . or it may damage the PLC. DVP-SX2 is small in size and easy to install. DVP-SX2 is a 20-point (8DI + 6 DO + 4AI + 2AO) PLC MPU. please refer to “DVP-SX2 Operation Manual: Programming”. Polyswitch -1- . output 24VDC/1A(PS02: 2A) Inrush current Fuse capacity Max. Check all the wiring prior to power up. To prevent any electromagnetic noise. general functions. please refer to the instruction sheet enclosed in the package. DO NOT touch terminals when power on. 480 input/output extension points). This instruction sheet provides only information on the electrical specification. For detailed program design and applicable instructions for DVP-SX2. Its 2-group high-speed (100kHz) pulse outputs and the one new 2-axis interpolation instructions satisfy all kinds of applications. installation and wiring. humidity. D/A transformation and temperature units) and all kinds of new high-speed extension modules. IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea) 243g 224g Input Point 24VDC (-15% ~ 20%) single common port input X0. rated consumption approx.5W (30VDC) 2μs 3μs 20μs 30μs 100μs 100μs 20WDC/100WAC Approx. Y5 1kHz SX211T: 0.). 10 ms #1: DVP20SX211T: UP.3 0. Digital I/O: 1KV.5A/1 point (5A/COM) #2 Off On On Off Off On On Off Adjustable within 0 ~ 20ms by D1020 (Default: 10ms) Output Point Transistor Y0.Model Item Power consumption Insulation resistance Noise immunity DVP20SX211R 4. Items Output No.7 1 2 Current(A) Contact [ Figure 3 ] -2- .5 0. < 30VDC 1. frequency Working voltage Resistive Max.4) 120VAC Inductive(cosψ=0.3A/1 point (1.7K Ohm > 15VDC < 5VDC < 2. ZP must work with external auxiliary power supply 5~30VDC. Y3 10kHz 5 ~ 30VDC #1 Y4. Pollution degree2 Storage: -25°C ~ 70°C (temp. ZP must work with external auxiliary power supply 24VDC (-15% ~ +20%).5A/1 point (3A/ZP) SX211S: 0.4) Operation(X10 3) 500 300 200 100 50 0. Input type Input Current (± 10%) Input impedance Action level Response time Filter time Spec. 10V/m The diameter of grounding wire cannot be smaller than the wire diameter of terminals 24V and 0V (All DVP units should be grounded directly to the ground pole). load Inductive Lamp Response time Off On On Off Relay Y0 ~ Y5 1Hz 250VAC.8A/UP) 15W (30VDC) 2. 5mA/point. Items Input No.5μs < 5μs < 10μs < 20μs < 20us < 50us X4 ~ X7 227g Grounding Operation / storage Vibration / shock resistance Weight (g) Spec.). DVP20SX211S: UP. 50 ~ 95% (humidity). Analog & Comm. 3mA/point.2 0. Max. Y2 100kHz Y1. 5mA 4. X2 X1. Operation: 0°C ~ 55°C (temp. 5 ~ 95% (humidity) International standards: IEC61131-2. I/O: 1KV RS: 26MHz ~ 1GHz. #2: Life curves 3000 2000 1000 120VAC Resistive 30VDC Inductive(t= 7ms) 240VAC Inducti ve(cosψ= 0. rated consumption approx.7W DVP20SX211T 4W DVP20SX211S 4W > 5MΩ (all I/O point-to-ground: 500VDC) ESD: 8KV Air Discharge EFT: Power Line: 2KV. X3 DC (SINK or SOURCE) 24VDC.1 30VDC Inductive (t=40ms) 0. #4: When the scan period is longer than 2ms. the present value will be read.000 4 ~ 20mA#1 0 ~ +2. #5: When the sampling range is “1”.000 Current ±20mA ±2. the setting will follow the scan period.000 0 ~ +4.5Ω or lower < 500Ω Non-linear accuracy: ±1% of full scale within the range of PLC operation temperature Maximum deviation: ±1% of full scale at 20mA and +10V 2ms (set up in D1118) #3 ±15V ±32mA 2ms #4 - 2’s complement of 16-bit.A/D and D/A Specifications Items Analog I/O range Digital conversion range Resolution #2 Input impedance Output impedance Tolerance carried impedance Overall accuracy Response time Absolute input range Digital data format Average function Isolation method Protection > 1MΩ > 5KΩ 250Ω Analog Input (A/D) Voltage ±10V ±2. the setting will follow the scan period. - #1: Please refer to the detailed explanation of D1115. I/O Configuration Model Input Point Type Point Output Type Relay DC (Sink Or Source) Relay V0+ I0+ VI0V1+ I1+ VI1V2+ I2+ VI2V3+ I3+ VI3FE VO0 IO0 VO1 IO1 AG S/S X0 X1 X2 X3 X4 X5 X6 X7 C0 Y0 Y1 Y2 C1 Y3 Y4 Y5 I/O configuration NPN V0+ I0+ VI0V1+ I1+ VI1V2+ I2+ VI2V3+ I3+ VI3FE VO0 IO0 VO1 IO1 AG S/S X0 X1 X2 X3 X4 X5 X6 X7 UP ZP Y0 Y1 Y2 Y3 Y4 Y5 PNP V0+ I0+ VI0V1+ I1+ VI1V2+ I2+ VI2V3+ I3+ VI3FE VO0 IO0 VO1 IO1 AG S/S X0 X1 X2 X3 X4 X5 X6 X7 UP ZP Y0 Y1 Y2 Y3 Y4 Y5 20SX211R 20SX211T 8 6 NPN Transistor PNP Transistor 20SX211S SX2-R/T/S 4 Analog Input 2 Analog output Dimension & Installation Please install the PLC in an enclosure with sufficient space around it to allow heat dissipation.000 ±10V ±2. but a long period of short circuit may cause internal wire damage and open circuit of current output. as shown in the [Figure 5].000 12-bit 0. 12 significant bits Provided (set up in D1062) #5 No Isolation between digital circuit and analog circuit Voltage output has short circuit protection. #2: Resolution formula Analog Input (A/D) Analog Output (D/A) Voltage Current Voltage Current 20V 40mA 20V 20mA (5mV = ) (10 μΑ = ) (5mV = ) (5 μΑ = ) 4000 4000 4000 4000 #3: When the scan period is longer than 2ms or the set value.000 Analog Output (D/A) Voltage Current 0 ~ 20mA 4 ~ 20mA#1 0 ~ +4. -3- . 2. place it onto the rail and gently push it up. be sure to use the retaining clip to stop any side-to-side movement of the PLC and reduce the chance of wires being loose. to ensure normal heat dissipation of the PLC. Users are suggested to install the protection circuit at the power supply terminal to protect DVPPS01 or DVPPS02. Delta power supply modules (DVPPS01/DVPPS02) are suitable power supplies for DVP-SX2. 70 53. pull the retaining clip down with a flat screwdriver and gently remove the PLC from DIN rail. DO NOT wire empty terminal and place the I/O signal cable in the same wiring circuit.5mm) single or multiple core wire 22-16AWG on I/O wiring terminals. DO NOT drop tiny metallic conductor into the PLC while screwing and wiring.90 kg-cm (1. Use 22-16AWG (1. 1 ○ 3 ○ 4 ○ 3 AC power supply:100 ~ 240VAC. 50/60Hz 2 ○ Breaker Emergency stop: This button cuts off the system power supply when accidental emergency takes place.2 V0+ I0+ VI0V1+ I1+ VI1V2+ I2+ 109. Power indicator -45 ○ AC power supply load . pull down the clip.Direct Mounting: Please use M4 screw according to the dimension of the product.4 101 VI2V3+ I3+ VI3FE VO0 IO0 VO1 IO1 AG 90 Unit: mm 3 [ Figure 4 ] Wiring 1. PLC terminal screws should be tightened to 1. 3.65 in-lbs) and please use only < 1. Safety Wiring Since DVP-SX2 is only compatible with DC power supply. See the figure below. DIN Rail Mounting: When mounting the PLC to 35mm DIN rail. The retaining clip is at the bottom of the PLC.5mm 60/75ºC copper conductor. To secure the PLC to DIN rail. Tear off the sticker on the heat dissipation hole for preventing alien substances from dropping in. To remove the PLC. See the figure in the right hand side for its specification. 3. as shown in the [Figure 10]. When output points are enabled. For detailed point configuration. and Y2. and the range of power is 20. please note the following points: 1. However. 500mA Digital I/O module 7 ○ 9 ○ DVPPS01/DVPPS02 DVP-PLC (main processing unit) Power Supply The power input of DVP-SX2 series is DC. PLC will stop running. Relay (R) output circuit wiring -5- .) DC Signal IN – SINK mode Input point loop equivalent circuit +24V 24G S/S DC Signal IN – SOURCE mode Input point loop equivalent circuit +24V 24G S/S X0 X0 X1 X1 [ Figure 7 ] [ Figure 8 ] Output Point Wiring 1. 2. please refer to the specification of each model.4 ~ 28. ZP common port. Output terminals. the PLC will automatically resume operation. Y0. 4. Isolation circuit: The optical coupler is used to isolate signals between the circuit inside PLC and input modules. If the power voltage is less than 20. When the power returns to normal status. 2. relay and transistor (NPN/PNP). Be aware of the connection of shared terminals when wiring output terminals.8VDC. Y0 ~Y5 of transistor (NPN/PNP) models use UP. When operating DVP-SX2 series. Y4. their corresponding indicators on the front panel will be on. all outputs will go “Off” and ERROR indicator will flash continuously. as shown in the [Figure 9].4VDC. 24VDC and 0V. The power is connected to the two terminals.6 ○ 8 ○ 10 ○ Power supply circuit protection fuse (2A) DC power supply output: 24VDC. The power shutdown of less than 10 ms will not affect the operation of the PLC. Output terminals. Input Point Wiring There are 2 types of DC inputs. power shutdown time that is too long or the drop of power voltage will stop the operation of the PLC and all outputs will go OFF. of relay models use C0 common port. Y1. DVP-SX2 series have three output modules. Y3. (See the example below. SINK and SOURCE. (Care should be taken on the latched auxiliary relays and registers inside the PLC when programming). and Y5 use C1 common port. to ensure safe protection in case of any unexpected errors. Diode suppression: Used when in smaller power (Figure 15a) 2. together with the PLC internal program.1A to ensure normal operation of the model. together with the PLC internal program. If Y0/Y1 is set to pulse output.PNP type (SX211S): 1 ○ 4 ○ DC power supply 2 ○ Emergency stop 3 ○ Circuit protection fuse The output of the transistor model is “open collector”. forming an interlock for the external circuit. Absorber: To reduce the interference on AC load (Figure 13) 8 ○ Transistor (T) output circuit wiring Transistor output . to ensure safe protection in case of any unexpected errors. 1.1 ○ 3 ○ 4 ○ DC power supply 2 ○ Emergency stop: Uses external switch Fuse: Uses 5~10A fuse at the shared terminal of output contacts to protect the output circuit Transient voltage suppressor (SB360 3A 60V): To extend the life span of contact.NPN type (SX211T): Transistor output . Diode + Zener suppression of DC load: Used when in larger power and frequent On/Off (Figure 12b) Incandescent light (resistive load) 6 ○ 5 ○ 7 ○ AC power supply Manually exclusive output: For example. Y3 and Y4 control the forward running and reverse running of the motor. Diode suppression of DC load: Used when in smaller power (Figure 12a) 2. -6- 5 ○ . the output current has to be bigger than 0. 1. forming an interlock for the external circuit. Y3 and Y4 control the forward running and reverse running of the motor. Diode + Zener suppression: Used when in larger power and frequent On/Off (Figure 15b) Manually exclusive output: For example. recorder. When voltage drop occurs between the internal ground references of two systems. recorder.A/D and D/A External Wiring A/D: Active 1 Voltage input A/D: Passive CH1 1 Voltage input UI N + 4 Shielded V0+ I0+ VI0- + UIN 4 Shielded CH1 V0+ I0+ V0- 2 Current input cable CH3 cable UI N + 4 Shielded V3+ I3+ VI3FE 2 Current input CH3 + Terminal of power module 3 5 Grounding (100 4 Shielded cable V3+ I3+ VI3FE 3 cable Terminal of power module 0V 0V 24V 5 Grounding (100 24V or less) [ Figure 17 ] or less) [ Figure 16 ] D/A 6 Voltage output CH1 4 8 VO0 IO0 AC drive.. connect the systems with Signal Ground point (SG) for achieving equal potential between systems so that a stable communication can be obtained.. 4 Isolation wire [ Figure 18 ] Note: When the A/D module is connected to current signals. RS-485 Wiring 1 D+ D. 3. 2. please apply double shielded twisted pair cable (20AWG) for wiring. Terminal resistors are suggested to be connected to master and the last slave with resistor value of 120Ω.. scale value..SG 3 2 D+ D. Isolation wire CH2 VO1 IO1 AG 7 Current output 8 AC drive. -7- . To ensure communication quality. make sure to short-circuit “V+” and “I+” terminals. scale value.SG SG D+ D3 2 4 1 ○ 3 ○ 4 2 ○ 4 ○ Figure 19 Master node Terminal resistor Slave node Shielded cable Note: 1.
Copyright © 2024 DOKUMEN.SITE Inc.