Draka Catalog

March 17, 2018 | Author: bodiemcd | Category: Cable, Electrical Conductor, Insulator (Electricity), Manufactured Goods, Electromagnetism


Comments



Description

Prepared by: Bodie McDaniel Prepared for: Talland Navigation Date: 19 Feb 2013 Project: N527 CONTENTS Bostrig 125 Type P Control 10&12AWG ................................................................................................................ 1 Bostrig 125 Type P Control 12&10AWG ................................................................................................................ 3 Bostrig 125 Type P Control 14AWG ...................................................................................................................... 5 Bostrig 125 Type P Control 16AWG ...................................................................................................................... 7 Bostrig 125 Type P Control 16AWG AS Bostrig 125 Type P Control 18AWG ...................................................................................................................... 11 Bostrig 125 Type P Control 18AWG AS Bostrig 125 Type P Power 2C ................................................................................................................. 9 ................................................................................................................. 13 ............................................................................................................................ 15 Bostrig 125 Type P Power 2C AS .......................................................................................................................... 17 Bostrig 125 Type P Power 3C AS .......................................................................................................................... 19 Bostrig 125 Type P Power 4C ............................................................................................................................ 21 Bostrig 125 Type P Power 4C AS Bostrig 125 Type P Power 5C .......................................................................................................................... 23 ............................................................................................................................ 25 Bostrig 125 Type P Power 5C AS .......................................................................................................................... 27 Bostrig 125 Type P Signal Cable ........................................................................................................................... 29 Bostrig 125 Type P Signal Cable ........................................................................................................................... 31 Bostrig 125 Type P Signal IO P 16&14AWG ......................................................................................................... 33 Bostrig 125 Type P Signal IO P 16&14AWG AS Bostrig 125 Type P Signal IO P 20&18AWG ......................................................................................................... 37 Bostrig 125 Type P Signal IO P 20&18AWG AS Bostrig 125 Type P Signal IO T 18&16AWG .................................................................................................... 39 .......................................................................................................... 41 Bostrig 125 Type P Signal IO T 18&16AWG AS Bostrig 125 Type P VFD 2kV .................................................................................................... 35 .................................................................................................... 43 ............................................................................................................................ 45 II CONTENTS This catalog represents only a partial selection of Draka Marine, Oil & Gas International wire and cable products, based on criteria submitted when requesting the information. For a complete list of Draka Marine, Oil & Gas International products, including specialty conversion and termination items, visit www.DrakaMOG.com. All products are subject to current availability. Please check with your Draka Marine, Oil & Gas International representative. All contents © 2007 Draka Marine, Oil & Gas International. All rights reserved. III Bostrig Type P 0807 Page 17 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV Multi-conductor / armored and sheathed TYPE P CONTROL CABLE 600V or 0.6/1kV 12 & 10 AWG 1 2 3 5 4 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs, marine vessels and oil and gas drilling rigs. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3. Bostrig cables have excellent resistance to oil, abrasion, moisture, sunlight and ester-based mud (Type P-MR). They are suitable for use in Class I, Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796. TM The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexible design. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3). American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 This product is readily available in an unarmored version. Construction 1. Conductors 2. Insulation 3. Jacket 4. Armor 5. Sheath Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor. Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001). Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version. Braided bronze in accordance with IEEE 1580 (2001). Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page. Features • Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact • Meets IEEE standards for 600V / IEC standards for 0.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3, Category A. Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for 600V. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. 1 www.DrakaMOG.com Bostrig Type P 0807 Page 18 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V or 0.6/1kV multi-conductor / armored and sheathed 12 & 10 AWG / 600V or 0.6/1kV 12 AWG • 3.08 mm2 Type Designation C12PNBS-2 C12PNBS-3 C12PNBS-4 C12PNBS-5 C12PNBS-6 C12PNBS-7 C12PNBS-8 C12PNBS-10 C12PNBS-12 C12PNBS-16 C12PNBS-20 C12PNBS-24 C12PNBS-30 C12PNBS-37 C12PNBS-44 C12PNBS-60 C12PNBS-91 Draka Number 026300 026301 026302 026303 026304 026305 026306 026307 026308 026309 026310 026311 026312 026313 026314 026315 026316 Number of Conductors 2 3 4 5 6 7 8 10 12 16 20 24 30 37 44 60 91 Insulation Thickness in • mm .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 Sheath Thickness in • mm .060 • 1.5 .060 • 1.5 .060 • 1.5 .060 • 1.5 .060 • 1.5 .060 • 1.5 .060 • 1.5 .080 • 2.0 .080 • 2.0 .080 • 2.0 .080 • 2.0 .080 • 2.0 .080 • 2.0 .110 • 2.8 .110 • 2.8 .125 • 3.2 .125 • 3.2 Cable Diameter (nominal) in • mm .605 • 15.4 .620 • 15.8 .665 • 16.9 .710 • 18.0 .750 • 19.1 .750 • 19.1 .800 • 20.3 .940 • 23.9 .965 • 24.5 1.085 • 27.6 1.175 • 29.9 1.280 • 32.5 1.340 • 34.0 1.490 • 37.9 1.640 • 41.7 1.875 • 47.6 2.180 • 55.4 Cable Weight (approximate) Lbs/mft • Kg/km 250 • 372 285 • 424 325 • 484 370 • 551 415 • 618 435 • 647 485 • 722 620 • 923 680 • 1012 870 • 1295 1020 • 1518 1180 • 1756 1370 • 2039 1685 • 2508 1955 • 2909 2630 • 3914 3670 • 5462 Number of Conductors 2 3 4 5 6 7 8 10 Insulation Thickness in • mm .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 .030 • 0.76 Sheath Thickness in • mm .060 • 1.5 .060 • 1.5 .060 • 1.5 .060 • 1.5 .080 • 2.0 .080 • 2.0 .080 • 2.0 .080 • 2.0 Cable Diameter (nominal) in • mm .670 • 17.0 .695 • 17.7 .750 • 19.1 .820 • 20.8 .895 • 22.7 .895 • 22.7 .950 • 24.1 1.112 • 28.5 Cable Weight (approximate) Lbs/mft • Kg/km 315 • 469 370 • 551 430 • 640 500 • 744 600 • 893 640 • 952 710 • 1057 910 • 1354 10 AWG • 5.53 mm2 Type Designation C10PNBS-2 C10PNBS-3 C10PNBS-4 C10PNBS-5 C10PNBS-6 C10PNBS-7 C10PNBS-8 C100PNBS-10 Draka Number 026317 026318 026319 026320 026321 026322 026323 026324 Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3. This information is provided for reference only, please consult the factory or your representative to confirm all engineering information, This information is not meant to replace the information in the appropriate and applicable standard or code. Table 3 Table 4 Three Conductor Cable, four Conductor Cables with more than four Current Carrying Conductors Cables with three Current Carrying No of Conductors Conductors 45ºC Ambient Conductor Size Gauge CMA mm2 12 6,503 3.30 10 10,908 5.53 95ºC 26 37 100ºC 31 41 110ºC 33 44 2 4-6 7-9 10-20 21-30 31-40 41-60 61 and greater www.DrakaMOG.com Derating Factor from 3 Conductor Ampacity 0.8 0.7 0.5 0.45 0.40 0.35 0.30 UL 1309/CSA245 and the performance requirements of IEC 60092-3. mud. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. moisture. marine vessels and oil and gas drilling rigs. 0. control.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Lloyds Registry of Shipping Approval Certificates No. complying with Type N Neoprene as required in IEEE-1580 (2001). Flame-retardant Arctic Neoprene. E8794.com . Bostrig cables have excellent resistance to oil. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. signal and instrumentation applications for offshore. moisture. land rigs. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Conductors 2. Det Norske Veritas Type Approval Certificates E8792.6/1kV 12 & 10 AWG 1 2 3 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. meeting IEEE 1580 (2001). IEEE 1580 (2001). UL 1309/CSA 245 and IEEE 45 (1998) for 600V. abrasion. Category A. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). TM This product is readily available in an armored and sheathed version. sunlight. Bostrig Type P chemically cross-inked polyolefin (XLPO).Bostrig Type P 0807 Page 41 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV Multi-conductor / unarmored TYPE P CONTROL CABLE 600V or 0. E8793.3).2 No. 3 www. E8795 and E8796. Thickness as shown in tables on opposite page.DrakaMOG. Larger diameter cables carry a new flexible design. abrasion. Jacket Soft annealed stranded tinned copper per ASTM B 33. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 Construction 1. sunlight and ester-based mud (Type P-MR). Insulation 3. A polyester tape separator is used over the conductor. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. Listed by ETL per IEEE 1580 (2001). Features • Superior resistance to oil. 030 • 0. This information is provided for reference only.060 • 1.9 1.5 .030 • 0.565 • 14.7 1.5 .9 .030 • 0.880 • 47.76 .5 .6/1kV 12 AWG • 3.35 0.030 • 0.675 • 17.030 • 0.76 .030 • 0.030 • 0.8 0.525 • 13.1 .8 .76 .060 • 1.060 • 26.060 • 1.565 • 39.3 .120 • 28.76 . The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables.76 .5 .620 • 15.4 .030 • 0.060 • 1.76 .503 3.40 0.08 mm2 Type Designation C12PN-2 C12PN-3 C12PN-4 C12PN-5 C12PN-6 C12PN-7 C12PN-8 C12PN-10 C12PN-12 C12PN-16 C12PN-20 C12PN-24 C12PN-30 C12PN-37 C12PN-44 C12PN-60 C12PN-91 Draka Number 026224 026225 026226 026227 026228 026229 026230 026231 026232 026233 026234 026235 026236 026237 026238 026239 026240 Number of Conductors 2 3 4 5 6 7 8 10 12 16 20 24 30 37 44 60 91 Insulation Thickness in • mm .0 .060 • 1.030 • 0.030 • 0.7 0.2 Cable Diameter (nominal) in • mm .45 0.5 .030 • 0.0 .76 Sheath Thickness in • mm .865 • 22.76 .76 .5 .3 .030 • 0.080 • 2.76 .2 .060 • 1.76 .5 .8 .76 .5 .030 • 0.0 .620 • 15.080 • 2.DrakaMOG.060 • 1.060 • 1.060 • 1.080 • 2.2 .5 .060 • 1.425 • 10.030 • 0.060 • 1.895 • 22.5 .030 • 0.0 .060 • 1.4 1.080 • 2.030 • 0.5 1.76 .76 . please consult the factory or your representative to confirm all engineering information.8 Cable Weight (approximate) Lbs/mft • Kg/km 100 • 149 135 • 201 155 • 231 190 • 283 220 • 327 245 • 365 280 • 417 355 • 528 400 • 595 550 • 818 680 • 1012 795 • 1183 955 • 1421 1140 • 1697 1390 • 2069 1880 • 2798 2800 • 4167 Number of Conductors 2 3 4 5 6 7 8 10 Insulation Thickness in • mm .76 .30 .030 • 0. This information is not meant to replace the information in the appropriate and applicable standard or code. four Conductor Cables with more than four Current Carrying Conductors Cables with three Current Carrying No of Conductors Conductors 45ºC Ambient Conductor Size Gauge CMA mm2 12 6.5 .5 .5 .8 1.53 95ºC 26 37 100ºC 31 41 110ºC 33 44 4 4-6 7-9 10-20 21-30 31-40 41-60 61 and greater www.675 • 17.060 • 1.76 .76 Sheath Thickness in • mm .030 • 0.955 • 24.730 • 18.030 • 0.440 • 11.76 .2 .5 .745 • 18. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.76 .76 .76 .2 .8 .5 .76 .080 • 2.6/1kV multi-conductor / unarmored 12 & 10 AWG / 600V or 0.210 • 30.5 0.570 • 14.060 • 1.6 .080 • 2.0 .060 • 1.5 .com Derating Factor from 3 Conductor Ampacity 0.030 • 0.5 .Bostrig Type P 0807 Page 42 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.030 • 0.5 .520 • 13.5 .76 .5 .0 . Table 3 Table 4 Three Conductor Cable.0 .060 • 1.125 • 3.110 • 2.30 10 10.080 • 2.76 .030 • 0.53 mm2 Type Designation C10PN-2 C10PN-3 C10PN-4 C10PN-5 C10PN-6 C10PN-7 C10PN-8 C10PN-10 Draka Number 026241 026242 026243 026244 026245 026246 026247 026248 Control cables are not intended for continuous current carrying applications.490 • 12.030 • 0.355 • 34.030 • 0. The current limit on these cables should be for providing control functions through relays and switching devices.720 • 18.908 5.76 .7 Cable Weight (approximate) Lbs/mft • Kg/km 115 • 171 200 • 298 240 • 357 295 • 439 350 • 521 390 • 580 445 • 662 590 • 878 10 AWG • 5.0 Cable Diameter (nominal) in • mm .030 • 0.570 • 14.3 1.475 • 12. control. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 Construction 1. moisture. abrasion.3). Det Norske Veritas Type Approval Certificates E8792. IEEE 1580 (2001). sunlight. UL 1309/CSA245 and the performance requirements of IEC 60092-3. E8795 and E8796. Larger diameter cables carry a new flexible design. moisture. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. Flame-retardant Arctic Neoprene. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Jacket Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor. meeting IEEE 1580 (2001). crush and impact • Meets IEEE standards for 600V / IEC standards for 0. Listed by ETL per IEEE 1580 (2001).6/1kV 14 AWG 1 2 3 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. mud. E8794. E8793. Insulation 3. Features • Superior resistance to oil. signal and instrumentation applications for offshore.com . land rigs. sunlight and ester-based mud (Type P-MR). Conductors 2. Lloyds Registry of Shipping Approval Certificates No.2 No. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.DrakaMOG.6/1kV Multi-conductor / unarmored TYPE P CONTROL CABLE 600V or 0. abrasion. Thickness as shown in tables on oppposite page. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. TM This product is readily available in an armored and sheathed version. 5 www. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). 0. Bostrig cables have excellent resistance to oil.Bostrig Type P 0807 Page 39 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0. Bostrig Type P chemically cross-inked polyolefin (XLPO). Category A. marine vessels and oil and gas drilling rigs. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. complying with Type N Neoprene as required in IEEE-1580 (2001). 76 0.030 .030 .5 1. This information is not meant to replace the information in the appropriate and applicable standard or code.40 0.76 0.76 0.5 1.1 .35 0.76 0.76 0.5 1.060 .7 .030 .8 0. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.9 .76 0.5 1. please consult the factory or your representative to confirm all engineering information.215 • 30.5 1.060 .560 • 14.5 1.380 • 6.030 .76 0.060 .76 0.345 • 34.060 .30 .106 2.76 Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km .0 2.475 • 12.030 .76 0.76 0.060 .5 1.76 0.76 0.030 .670 • 17.76 0.94 mm2 Type Designation Draka Number Number of Conductors C14PN-2 C14PN-3 C14PN-4 C14PN-5 C14PN-6 C14PN-7 C14PN-8 C14PN-10 C14PN-12 C14PN-16 C14PN-20 C14PN-24 C14PN-30 C14PN-37 C14PN-44 C14PN-60 C14PN-91 026207 026208 026209 026210 026211 026212 026213 026214 026215 026216 026217 026218 026219 026220 026297 026298 026299 2 3 4 5 6 7 8 10 12 16 20 24 30 37 44 60 91 Insulation Thickness in • mm .030 .030 .5 2.030 .060 .080 .08 95ºC 20 100ºC 25 110ºC 27 6 4-6 7-9 10-20 21-30 31-40 41-60 61 and greater www.45 0.060 .030 • • • • • • • • • • • • • • • • • 0. The current limit on these cables should be for providing control functions through relays and switching devices.2 .060 .2 1.740 • 18.5 .0 Control cables are not intended for continuous current carrying applications.1 .820 • 20.430 • 10.080 .0 2.030 .1 1.0 .com Derating Factor from 3 Conductor Ampacity 0.030 .030 .6/1kV • 1.5 0.080 .9 1.515 • 13. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables.9 77 • 115 100 • 149 115 • 171 147 • 218 165 • 246 180 • 268 210 • 313 260 • 387 290 • 432 375 • 558 495 • 737 585 • 871 695 • 1034 850 • 1265 990 • 1473 1300 • 1935 1980 • 2947 • • • • • • • • • • • • • • • • • 1.0 2.650 • 41.080 .060 .5 1.005 • 25.950 • 24.390 • 9.6/1kV multi-conductor / unarmored 14 AWG / 600V or 0.650 • 16.030 .080 . four Conductor Cables with more than four Current Carrying Conductors Cables with three Current Carrying No of Conductors Conductors 45ºC Ambient Conductor Size Gauge CMA mm2 14 4. This information is provided for reference only.76 0.5 1.7 0.030 .1 .8 .8 . Table 3 Table 4 Three Conductor Cable.DrakaMOG.5 1.030 .515 • 13.9 .5 1.0 2.060 .060 .080 • 27.Bostrig Type P 0807 Page 40 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.4 1.76 0.76 0.030 .060 .5 1. E8795 and E8796.com . Lloyds Registry of Shipping Approval Certificates No. E8794. Det Norske Veritas Type Approval Certificates E8792. UL 1309/CSA245 and the performance requirements of IEC 60092-3. mud.6/1kV Multi-conductor / unarmored TYPE P CONTROL CABLE 600V or 0. sunlight and ester-based mud (Type P-MR). Features • Superior resistance to oil. Listed by ETL per IEEE 1580 (2001). sunlight. Flame-retardant Arctic Neoprene. land rigs. Bostrig Type P chemically cross-inked polyolefin (XLPO). The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. moisture. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. Thickness as shown in tables on opposite page. 0. IEEE 1580 (2001).DrakaMOG.3). meeting IEEE 1580 (2001). moisture. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. A polyester tape separator is used over the conductor. abrasion. TM This product is readily available in an armored and sheathed version. Conductors 2. 7 www. control. Category A. Bostrig cables have excellent resistance to oil. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. signal and instrumentation applications for offshore. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. Jacket Soft annealed stranded tinned copper per ASTM B 33. marine vessels and oil and gas drilling rigs. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998).Bostrig Type P 0807 Page 37 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0. E8793.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 Construction 1. abrasion.6/1kV 16 AWG 1 2 3 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power.2 No. Insulation 3. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. complying with Type N Neoprene as required in IEEE-1580 (2001). Larger diameter cables carry a new flexible design. 9 1.080 .76 0.0 Control cables are not intended for continuous current carrying applications.060 .0 1.76 0.5 1.0 1.45 0.Bostrig Type P 0807 Page 38 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.030 .030 • • • • • • • • • • • • • • • • • 0.5 1.1 .745 • 18.030 .9 .400 • 10. This information is not meant to replace the information in the appropriate and applicable standard or code.76 0.0 2.840 • 21.5 1.76 0.060 .370 • 9.5 0.030 .060 .23 mm2 Type Designation Draka Number Number of Conductors C16PN-2 C16PN-3 C16PN-4 C16PN-5 C16PN-6 C16PN-7 C16PN-8 C16PN-10 C16PN-12 C16PN-16 C16PN-20 C16PN-24 C16PN-30 C16PN-37 C16PN-44 C16PN-60 C16PN-91 026190 026191 026192 026193 026194 026195 026196 026197 026198 026199 026200 026201 026202 026203 026204 026205 026206 2 3 4 5 6 7 8 10 12 16 20 24 30 37 44 60 91 Insulation Thickness in • mm .475 • 12.30 .030 .0 2.6/1kV multi-conductor / unarmored 16 AWG / 600V or 0.030 .480 • 37.1 .76 0.35 0.060 .030 .030 .5 1.76 Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km .8 0.060 .985 • 25.610 • 15.030 .com Derating Factor from 3 Conductor Ampacity 0.060 .5 .76 0.080 .030 .6/1kV • 1.76 0.5 1.2 .220 • 31.76 0.76 0.475 • 12.32 95ºC 16 100ºC 17 110ºC 18 8 4-6 7-9 10-20 21-30 31-40 41-60 61 and greater www.030 .7 .76 0.40 0.76 0.0 2.030 .030 .030 .5 1.7 0.061 1.100 • 27. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables.76 0.2 .76 0.060 .5 2. This information is provided for reference only.2 .76 0.675 • 17.060 .5 1.915 • 23.595 • 15. four Conductor Cables with more than four Current Carrying Conductors Cables with three Current Carrying No of Conductors Conductors 45ºC Ambient Conductor Size Gauge CMA mm2 16 2.355 • 9.1 .76 0. Table 3 Table 4 Three Conductor Cable.030 .3 .060 .060 .2 .540 • 13. please consult the factory or your representative to confirm all engineering information.0 2.060 . The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3. The current limit on these cables should be for providing control functions through relays and switching devices.030 .DrakaMOG.76 0.5 1.5 1.5 1.440 • 11.080 .6 65 • 97 80 • 119 95 • 141 115 • 171 135 • 201 145 • 216 160 • 238 200 • 298 225 • 335 285 • 424 350 • 521 440 • 655 520 • 774 625 • 930 735 • 1094 960 • 1429 1470 • 2188 • • • • • • • • • • • • • • • • • 1.030 .5 1.4 .0 .080 .060 .080 . Listed by ETL per IEEE 1580 (2001). Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. 9 www. E8794. Braided bronze in accordance with IEEE 1580 (2001). 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 This product is readily available in an unarmored version. land rigs.3). moisture. Thickness as shown in tables on opposite page. complying with Type N Neoprene as required in IEEE-1580 (2001). Armor 5.6/1kV 16 AWG 1 2 3 5 4 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. control. Insulation 3. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. mud. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Bostrig cables have excellent resistance to oil. abrasion.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3.com . They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. E8795 and E8796. Thickness as shown on data sheet for unarmored version. Flame-retardant Arctic Neoprene applied over the armor.Bostrig Type P 0807 Page 13 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0. Flame-retardant Arctic Neoprene.DrakaMOG. They are suitable for use in Class I. Category A.2 No. sunlight. Sheath Soft annealed stranded tinned copper per ASTM B 33.6/1kV Multi-conductor / armored and sheathed TYPE P CONTROL CABLE 600V or 0. Conductors 2. abrasion. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. marine vessels and oil and gas drilling rigs. moisture. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. TM The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. meeting IEEE 1580 (2001). Construction 1. Lloyds Registry of Shipping Approval Certificates No. A polyester tape separator is used over the conductor. Features • Superior resistance to oil. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). E8793. IEEE 1580 (2001). Larger diameter cables carry a new flexible design. 0. sunlight and ester-based mud (Type P-MR). Det Norske Veritas Type Approval Certificates E8792. Jacket 4. UL 1309/CSA245 and the performance requirements of IEC 60092-3. complying with Type N Neoprene as required in IEEE 1580 (2001). Bostrig Type P chemically cross-inked polyolefin (XLPO). signal and instrumentation applications for offshore. 6 .8 .5 1.8 0. This information is not meant to replace the information in the appropriate and applicable standard or code.620 • 15.030 .0 2.500 • 38.1 1.080 .0 2.6/1kV multi-conductor / armored and sheathed 16 AWG / 600V or 0.060 .0 .030 .5 1.060 .8 2. The current limit on these cables should be for providing control functions through relays and switching devices.8 Control cables are not intended for continuous current carrying applications.060 .76 0.23 mm2 Type Designation C16PNBS-2 C16PNBS-3 C16PNBS-4 C16PNBS-5 C16PNBS-6 C16PNBS-7 C16PNBS-8 C16PNBS-10 C16PNBS-12 C16PNBS-16 C16PNBS-20 C16PNBS-24 C16PNBS-30 C16PNBS-37 C16PNBS-44 C16PNBS-60 C16PNBS-91 Draka Number Number of Conductors 026266 026267 0262668 026269 026270 026271 026272 026273 026274 026275 026276 026277 026278 026279 026280 026281 026282 2 3 4 5 6 7 8 10 12 16 20 24 30 37 44 60 91 Insulation Thickness in • mm .76 0.76 0.060 .965 • 24.76 0.770 • 45.5 1.080 .7 1.030 .40 0.76 0.080 .110 .76 0. four Conductor Cables with 4 or more Current Carrying Conductors Cables with three Current Carrying No of Conductors Conductors 45ºC Ambient Conductor Size Gauge CMA mm2 16 2. This information is provided for reference only.45 0.76 0.5 1.030 .0 2.030 .5 1.720 • 18.790 • 20.205 • 30.76 0.30 .110 .050 • 26. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.8 1.5 1.775 • 19.655 • 16.32 95ºC 16 100ºC 17 110ºC 18 10 4-6 7-9 10-20 21-30 31-40 41-60 61 and greater www.030 . Table 3 Table 4 Three Conductor Cable.76 0.601 1.76 Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km .5 1.030 .030 .5 1.0 190 • 283 205 • 305 235 • 350 265 • 394 295 • 439 300 • 446 340 • 506 400 •595 430 • 640 545 • 811 635 • 945 755 •1124 865 • 1287 995 • 1480 1125 • 1674 1495 • 2225 2100 • 3125 • • • • • • • • • • • • • • • • • 1.5 1.6 .030 • • • • • • • • • • • • • • • • • 0.1 .895 • 22.535 • 13.6 .76 0. please consult the factory or your representative to confirm all engineering information.320 • 33.7 .030 .0 2.76 0.060 .3 .35 0.080 .135 • 28.060 .0 2.030 .76 0.060 .7 0.76 0.030 .030 .5 1.com Derating Factor from 3 Conductor Ampacity 0.060 .030 .030 .030 .76 0.545 • 13.DrakaMOG.8 .030 .5 2.6 1.655 • 16.080 .6/1kV • 1.5 0.76 0.590 • 15. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables.060 .7 .080 .Bostrig Type P 0807 Page 14 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V or 0.76 0.0 2. E8794. abrasion. sunlight. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. Insulation 3. E8793.3). land rigs. Lloyds Registry of Shipping Approval Certificates No. Jacket Soft annealed stranded tinned copper per ASTM B 33. moisture. abrasion.2 No.6/1kV 18 AWG 1 2 3 Approvals Applications BostrigTM Type P Marine and Offshore Cable is primarily designed for power. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. E8795 and E8796. Det Norske Veritas Type Approval Certificates E8792. Conductors 2. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. This product is readily available in an armored and sheathed version. Flame-retardant Arctic Neoprene. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. moisture. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 Construction 1. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. UL 1309/CSA245 and the performance requirements of IEC 60092-3. meeting IEEE 1580 (2001). control. mud. signal and instrumentation applications for offshore. Bostrig Type P chemically cross-inked polyolefin (XLPO). complying with Type N Neoprene as required in IEEE-1580 (2001).Bostrig Type P 0807 Page 35 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0. A polyester tape separator is used over the conductor.6/1kV Multi-conductor / unarmored TYPE P CONTROL CABLE 600V or 0.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3.DrakaMOG. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels.com . Listed by ETL per IEEE 1580 (2001). 11 www. sunlight and ester-based mud (Type P-MR). Thickness as shown in tables on opposite page. Category A. Features • Superior resistance to oil. marine vessels and oil and gas drilling rigs. IEEE 1580 (2001). 0. Larger diameter cables carry a new flexible design. Bostrig cables have excellent resistance to oil. 5 1.76 0.76 0.5 1.9 .76 0.080 .030 . This information is provided for reference only.0 2.5 1.8 .030 .060 . This information is not meant to replace the information in the appropriate and applicable standard or code.6/1kV multi-conductor / unarmored 18 AWG / 600V or 0. four Conductor Cables with more than four Current Carrying Conductors Cables with three Current Carrying No of Conductors Conductors 45ºC Ambient Conductor Size Gauge CMA mm2 18 1.9 .060 .030 .460 • 11.165 • 29.5 1.030 .1 .620 0.7 . The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.030 .030 .5 .570 • 14.30 .030 .76 0.360 • 9.030 .76 0.5 1.2 . The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables.030 .82 95ºC 11 100ºC 12 110ºC 13 12 4-6 7-9 10-20 21-30 31-40 41-60 61 and greater www.96 mm2 Type Designation Draka Number Number of Conductors C18PN-2 C18PN-3 C18PN-4 C18PN-5 C18PN-6 C18PN-7 C18PN-8 C18PN-10 C18PN-12 C18PN-16 C18PN-20 C18PN-24 C18PN-30 C18PN-37 C18PN-44 C18PN-60 C18PN-91 026173 026174 026175 026176 026177 026178 026179 026180 026181 026182 026183 026184 026185 026186 026187 026188 026189 2 3 4 5 6 7 8 10 12 16 20 24 30 37 44 60 91 Insulation Thickness in • mm .5 1.080 .030 .1 .080 .40 0.76 0.76 0.490 • 12.5 .425 • 10.5 1.76 0.76 Jacket Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km .76 0.390 • 9.6 .35 0.2 .585 • 14.0 2.0 2.340 • 8.390 • 35.76 0.5 2. Table 3 Table 4 Three Conductor Cable.5 0.030 .060 .460 • 11.940 • 23.76 0.8 1.790 • 20.030 .8 .030 .Bostrig Type P 0807 Page 36 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.060 .76 0.DrakaMOG.060 .76 0.030 • • • • • • • • • • • • • • • • • 0.8 0.875 • 22.030 .9 1.3 55 • 82 70 • 104 85 • 127 100 • 149 120 • 179 130 • 193 140 • 208 175 • 260 195 • 290 250 • 372 305 • 454 355 • 528 455 • 677 545 • 811 640 • 952 835 • 1243 1220 • 1816 • • • • • • • • • • • • • • • • • 1.5 1.76 0. please consult the factory or your representative to confirm all engineering information.060 .6/1kV • 0.030 .0 2.060 .45 0.060 .060 .060 .715 • 18.080 .660 • 16. The current limit on these cables should be for providing control functions through relays and switching devices.7 .060 .060 .5 1.76 0.5 1.76 0.7 0.0 Control cables are not intended for continuous current carrying applications.6 1.080 .055 • 26.com Derating Factor from 3 Conductor Ampacity 0.5 1.030 . 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 This product is readily available in an unarmored version. A polyester tape separator is used over the conductor.Bostrig Type P 0807 Page 11 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV Multi-conductor / armored and sheathed TYPE P CONTROL CABLE 600V or 0. land rigs. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.DrakaMOG. Category A. abrasion. signal and instrumentation applications for offshore. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. UL 1309/CSA245 and the performance requirements of IEC 60092-3. Thickness as shown in tables on opposite page.com . IEEE 1580 (2001). Jacket 4. Flame-retardant Arctic Neoprene. sunlight and ester-based mud (Type P-MR). Armor 5.6/1kV 18 AWG 1 2 3 5 4 Approvals Applications BostrigTM Type P Marine and Offshore Cable is primarily designed for power. Construction 1. mud. Larger diameter cables carry a new flexible design. complying with Type N Neoprene as required in IEEE-1580 (2001). abrasion. sunlight.2 No. Braided bronze in accordance with IEEE 1580 (2001). Bostrig Type P chemically cross-inked polyolefin (XLPO). Conductors 2. control. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. E8794. Features • Superior resistance to oil. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). marine vessels and oil and gas drilling rigs. moisture. Bostrig cables have excellent resistance to oil. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. Thickness as shown on data sheet for unarmored version. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. complying with Type N Neoprene as required in IEEE 1580 (2001). moisture. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Sheath Soft annealed stranded tinned copper per ASTM B 33.3). 13 www. Flame-retardant Arctic Neoprene applied over the armor. Lloyds Registry of Shipping Approval Certificates No. 0. Listed by ETL per IEEE 1580 (2001). They are suitable for use in Class I. Det Norske Veritas Type Approval Certificates E8792. E8795 and E8796. meeting IEEE 1580 (2001). E8793. Insulation 3. 35 0.8 Control cables are not intended for continuous current carrying applications.76 Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km .1 .030 .1 .76 0.5 1.1 .030 .650 • 41.640 • 16.060 .935 • 23.6 1.6/1kV • 0.4 .7 1. four Conductor Cables with more than four Current Carrying Conductors Cables with three Current Carrying No of Conductors Conductors 45ºC Ambient Conductor Size Gauge CMA mm2 18 1.76 0.030 .76 0.515 • 13.0 2.030 .030 .5 .275 • 32.5 1.030 .45 0.5 1.com Derating Factor from 3 Conductor Ampacity 0.030 .030 .0 2.6/1kV multi-conductor / armored and sheathed 18 AWG / 600V or 0.030 .765 • 19.76 0.640 • 16.030 .76 0.8 1.40 0.9 180 • 268 200 • 298 225 • 335 250 • 372 275 • 409 285 • 424 310 • 461 365 • 543 365 • 543 500 • 744 580 • 863 655 • 975 790 • 1176 900 • 1339 1035 • 1540 1355 • 2016 1860 • 2768 • • • • • • • • • • • • • • • • • 1.030 • • • • • • • • • • • • • • • • • 0.76 0. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables.030 .605 • 15. This information is provided for reference only.76 0.060 . please consult the factory or your representative to confirm all engineering information.0 2.DrakaMOG.0 2.060 .96 mm2 Type Designation Draka Number Number of Conductors C18PNBS-2 C18PNBS-3 C18PNBS-4 C18PNBS-5 C18PNBS-6 C18PNBS-7 C18PNBS-8 C18PNBS-10 C18PNBS-12 C18PNBS-16 C18PNBS-20 C18PNBS-24 C18PNBS-30 C18PNBS-37 C18PNBS-44 C18PNBS-60 C18PNBS-91 026249 026250 026251 026252 026253 026254 026255 026256 026257 026258 026259 026260 026261 026262 026263 026264 026265 2 3 4 5 6 7 8 10 12 16 20 24 30 37 44 60 91 Insulation Thickness in • mm .5 1.080 .060 .030 .100 • 27.5 1.750 • 19.620 0.080 .0 2.060 .76 0.080 .7 .76 0.060 .030 .010 • 25.030 .030 .1 .5 1.76 0.080 .76 0.060 .5 1.6 .5 0.110 .060 .5 2.060 .540 • 13.445 • 36.080 .8 0.76 0.670 • 17.080 .7 0. This information is not meant to replace the information in the appropriate and applicable standard or code.76 0.9 1.30 .7 1.76 0.575 • 14.885 • 22.82 95ºC 11 100ºC 12 110ºC 13 14 4-6 7-9 10-20 21-30 31-40 41-60 61 and greater www.76 0.165 • 29. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.3 .3 .5 1.0 2.030 .8 2. Table 3 Table 4 Three Conductor Cable.4 1.76 0. The current limit on these cables should be for providing control functions through relays and switching devices.Bostrig Type P 0807 Page 12 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V or 0.110 . moisture. sunlight. Insulation 3. Transport Canada Approved AMS400-20-2 Lloyds Registry of Shipping Approval Certificates No. Listed by ETL per IEEE 1580 (2001). E8793. abrasion. 0. E8795 and E8796. A polyester tape separator is used over the conductor.3). E8794.com . Flame-retardant Arctic Neoprene. marine vessels and oil and gas drilling rigs. abrasion. IEEE 1580 (2001). sunlight and ester-based mud (Type P-MR). The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels.6/1kV 8 AWG to 777 MCM 1 2 3 Applications Approvals BostrigTM Type P Marine and Offshore Cable is primarily designed for power. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). Jacket Soft annealed stranded tinned copper per ASTM B 33. Category A. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. Bostrig cables have excellent resistance to oil. This product is readily available in an armored and sheathed version. signal and instrumentation applications for offshore. 15 www. land rigs. Larger diameter cables carry a new flexible design.2 No.DrakaMOG. complying with Type N Neoprene as required in IEEE-1580 (2001).Bostrig Type P 0807 Page 27 of 62 BOSTRIG™ TYPE P POWER CABLE 600V OR 0. Features • Superior resistance to oil. Thickness as shown in tables on opposite page. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. control. Conductors 2.6/1kV Two conductor / unarmored TYPE P POWER CABLE 600V or 0. mud. UL 1309/CSA 245 and IEEE 45 (1998) for 600V & 2000V. Det Norske Veritas Type Approval Certificates E8792. UL 1309/CSA245 and the performance requirements of IEC 60092-3. 95/00161(E3) and 95-00162(E3) Manufactured to BIW Specifying Standard J105 CONSTRUCTION 1. crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600 & 2000V / IEC standards for 0.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. moisture. Bostrig Type P chemically cross-inked polyolefin (XLPO). meeting IEEE 1580 (2001). 0 0.140 • 3. 16 www.5 .03 • 0.3 173 • 567 121 • 132 • 141 605 • 900 DPN-2 026048 2 • 30.09 • 0.4 0. This information is not meant to replace the information in the appropriate and applicable standard or code.1 0.3 245 • 804 259 • 265 • 284 1860 • 2768 DPN-4/0 026053 4/0 • 112.12 • 0.2 0.5 0.6 2.870 • 22.2 2.140 • 3.06 • 0.1 0.125 • 3.0 0.11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature.8 .3 178 • 584 168 • 174 • 186 975 • 1451 DPN-1/0 026050 1/0 • 56.3 0.09 • 0.08 • 0.2 0.5 .3 0.0 .2 2.10 • 0.33 • 1.0 .1 0.900 • 73.12 • 0.0 1.1 0.3 259 • 850 293 • 307 • 329 2215 • 3296 DPN-262 026054 262 • 133.9 0.72.70 • 2.3 345 • 1132 641 • 684 • 733 7030 • 10462 Type Designation Inductance Capacitance mH/kft • mH/km pF/ft • pF/m This information is provided for reference only.04 • 0.6 .7 0.10 • 0.04 • 0.09 • 0.09 • 0.09 • 0.1OOºC values based on IEEE-45 Table 25 .5 .3 270 • 886 362 • 391 • 419 3035 • 4517 DPN-373 026056 373 • 189.4 0.0 0.810 • 20.9 0.29 • 1.6 0.1 0.985 • 25.4905 • 63.3 .110 • 2.6 .8 1.5 0.1 0.09 • 0.260 • 32.4 95 • 312 58 • 64 • 69 210 • 313 DPN-6 026044 6 • 12.060 • 1.8 1.1 .060 • 1.5 0.3 212 • 695 213 • 242 • 259 1285 • 1912 DPN-3/0 026052 3/0 • 92.10 • 0.6 0.09 • 0.3 190 • 623 190 • 199 • 213 1150 • 1711 DPN-2/0 026051 2/0 • 66.09 • 0.080 • 2.695 • 68.8 0.2 0.09 • 0.3 0.080 • 2.64.4 126 • 413 83 • 85 • 91 315 • 469 DPN-5 026045 5 • 18.11 • 0. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.705 • 17.590 • 15.18 • 0.7 .5 .57 .6/1kV Impedance (Phase-Neutral) Ω/kft .3 314 • 1030 570 • 632 • 677 5880 • 8750 DPN-777 026060 777 • 393.4 0.Ω/km Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Draka Number Conductor Size AWG/MCM • mm2 Jacket Thickness in • mm Cable Diameter (nominal) in • mm DPN-8 026043 8 • 7.3 153 • 502 104 • 110 • 118 520 • 774 DPN-3 026047 3 • 25.2 1. please consult the factory or your representative to confirm all engineering information.3 .3 187 • 613 138 • 149 • 160 685 • 1019 DPN-1 026049 1 • 46.3 291 • 954 507 • 538 • 576 4960 • 7381 DPN-646 026059 646 • 327.660 • 42.2 1.3 292 • 958 405 • 442 • 473 3615 • 5380 DPN-444 026057 444 • 225.09 • 0.125 • 3.09 • 0.105 • 53.6 2.3 247 • 810 325 • 358 • 383 2605 • 3877 DPN-313 026055 313 • 158.080 • 2.0 .0 0.66.04 • 0.23 • 0. 2 AWG thru 3/OAWG multiply by 0.5 .320 • 33.09 • 0.6 2.Bostrig Type P 0807 Page 28 of 62 BOSTRIG™ TYPE P POWER CABLE two conductor / unarmored 8 AWG to 777 MCM / 600V or 0. 4/0 AWG thru 1000 MCM multiply by O.6 .150 • 29.DrakaMOG.09 • 0.080 • 2.04 • 0.830 • 46.125 • 3.6 0.11 • 0.5 .6 .140 • 3.1 .com .5 0.46 • 1. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .5 0.14 • 0.05 • 0.060 • 1.245 • 57.110 • 2.0 0.0 .920 • 23.3 318 • 1043 451 • 504 • 540 4140 • 6161 DPN-535 026058 535 • 271.2 0.560 • 39.5 .080 • 2.0 .1 0.07 • 0.0 1.4 140 • 459 95 • 101 • 108 440 • 655 DPN-4 026046 4 • 21.080 • 2.965 • 49.125 • 3.2 0.5 0.2 .0 1. Features • Superior resistance to oil.Bostrig Type P 0807 Page 3 of 62 BOSTRIG™ TYPE P POWER CABLE 600V OR 0. E8794. complying with Type N Neoprene as required in IEEE 1580 (2001). meeting IEEE 1580 (2001). The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Bostrig Type P chemically cross-inked polyolefin (XLPO).2 No. Category A.3). Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J104 This product is readily available in an unarmored version. 95/00161(E3) and 95-00162(E3) American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. signal and instrumentation applications for offshore. moisture. Larger diameter cables carry a new flexible design. Braided bronze in accordance with IEEE 1580 (2001). Sheath Soft annealed stranded tinned copper per ASTM B 33. Lloyds Registry of Shipping Approval Certificates No. E8793. Det Norske Veritas Type Approval Certificates E8792. UL 1309/CSA 245 and IEEE 45 (1998) for 600V.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. marine vessels and oil and gas drilling rigs. abrasion.DrakaMOG. CONSTRUCTION 1. complying with Type N Neoprene as required in IEEE-1580 (2001). moisture.com .6/1kV 1 2 3 5 4 8 AWG to 777 MCM Applications Approvals BostrigTM Type P Marine and Offshore Cable is primarily designed for power. land rigs. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0. Flame-retardant Arctic Neoprene applied over the armor. control. E8795 and E8796. Conductors 2. Listed by ETL per IEEE 1580 (2001). Armor 5. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. abrasion. mud. 17 www. Thickness as shown on data sheet for unarmored version. 0. They are suitable for use in Class I. A polyester tape separator is used over the conductor. Jacket 4. Flame-retardant Arctic Neoprene. Bostrig cables have excellent resistance to oil. UL 1309/CSA245 and the performance requirements of IEC 60092-3. Thickness as shown in tables on opposite page. sunlight. Insulation 3. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. IEEE 1580 (2001).6/1kV Two conductor / armored and sheathed TYPE P POWER CABLE 600V or 0. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. sunlight and ester-based mud (Type P-MR). 3 318 • 1043 451 • 504 • 540 5240 • 7798 DPNBS-535 026123 535 • 271.09 • 0.0 0.5 0.04 • 0.5 0.72.4 0.3 173 • 567 121 • 132 • 141 940 • 1399 DPNBS-2 026113 2 • 30.080 • 2.03 • 0.09 • 0.040 • 26.3 0.01 0.0 1.12 • 0.6 .140 • 3.2 1.0 .0 .1 0.5 0.2 0.66.64.09 • 0.5 .155 • 3.4 0.3 190 • 623 190 • 199 • 213 1695 • 2522 DPNBS-2/0 026116 2/0 • 66.060 • 1. 4/0 AWG thru 1000 MCM multiply by O.0 1.125 • 3.3 153 • 502 104 • 110 • 118 850 • 1265 DPNBS-3 026112 3 • 25.140 • 29. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .975 • 50. 2 AWG thru 3/OAWG multiply by 0.09 • 0.DrakaMOG.2 0.7 0.04 • 0.70 • 2.4 0.3 314 • 1030 570 • 632 • 677 7185 • 10692 DPNBS-777 026125 777 • 393.2 0.9 2.05 • 0.0 0.8 0.0 .04 • 0.0 1. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.2 1.33 • 1.11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature. This information is not meant to replace the information in the appropriate and applicable standard or code.7 .8 0.1 0.6 2.445 • 62.09 • 0.3 .3 0.4 0.870 • 47.3 270 • 886 362 • 391 • 419 4005 • 5960 DPNBS-373 026121 373 • 189.110 • 2.08 • 0.09 • 0.10 • 0.14 • 0. 18 www.3 0.1 .765 • 19.29 • 1.920 • 23.065 • 77.1 0.7 0.8 1.com .09 • 0.3 212 • 695 213 • 242 • 259 1845 • 2746 DPNBS-3/0 026117 3/0 • 92.205 • 30.Ω/km Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Type Designation Draka Number Conductor Size AWG/MCM • mm2 Sheath Thickness in • mm Cable Diameter (nominal) in • mm DPNBS-8 026108 8 • 7.155 • 3.3 345 • 1132 641 • 684 • 733 8420 • 12530 Inductance Capacitance mH/kft • mH/km pF/ft • pF/m This information is provided for reference only.9 3.9 3.585 • 65.6 0.270 • 83.23 • 0.865 • 72.9 0.600 • 40.6 .155 • 3.2 0.1 0.2 .12 • 0.6/1kV Impedance (Phase-Neutral) Ω/kft .080 • 2. please consult the factory or your representative to confirm all engineering information.8 1.3 247 • 810 325 • 358 • 383 3445 • 5127 DPNBS-313 026120 313 • 158.3 178 • 584 168 • 174 • 186 1480 • 2202 DPNBS-1/0 026115 1/0 • 56.1OOºC values based on IEEE-45 Table 25 .5 0.5 .09 • 0.140 • 3.125 • 3.4 95 • 312 58 • 64 • 69 405 • 603 DPNBS-6 026109 6 • 12.6 .09 • 0.110 • 2.3 292 • 958 405 • 442 • 473 4650 • 6920 DPNBS-444 026122 444 • 225.1 0.080 • 2.07 • 0.09 • 0.4 126 • 413 83 • 85 • 91 580 • 863 DPNBS-5 026110 5 • 18.080 • 2.2 2.1 0.3 245 • 804 259 • 265 • 284 2585 • 3825 DPNBS-4/0 026118 4/0 • 112.11 • 0.0 0.6 2.090 • 27.535 • 39.1 0.09 • 0.3 .10 • 0.6 0.5 .4 140 • 459 95 • 101 • 108 720 • 1071 DPNBS-4 026111 4 • 21.3 0.46 • 1.18 • 0.3 259 • 850 293 • 307 • 329 2980 • 4435 DPNBS-262 026119 262 • 133.110 • 2.Bostrig Type P 0807 Page 4 of 62 BOSTRIG™ TYPE P POWER CABLE two conductor / armored and sheathed 8 AWG to 777 MCM / 600V or 0.11 • 0.080 • 2.3 291 • 954 507 • 538 • 576 6175 • 9189 DPNBS-646 026124 646 • 327.09 • 0.57 .6 0.1 .6 .04 • 0.10 • 0.5 .305 • 58.3 187 • 613 138 • 149 • 160 1045 • 1555 DPNBS-1 026114 1 • 46.125 • 3.6 0.140 • 3.5 .0 1.8 1.06 • 0.6 2.430 • 36.8 .145 • 54.09 • 0. Thickness as shown in tables on opposite page. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. 19 www.Bostrig Type P 0807 Page 5 of 62 BOSTRIG™ TYPE P POWER CABLE 600V OR 0. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0. Category A. marine vessels and oil and gas drilling rigs. complying with Type N Neoprene as required in IEEE-1580 (2001). 0. Flame-retardant Arctic Neoprene. UL 1309/CSA245 and the performance requirements of IEC 60092-3.2 No.6/1kV Three conductor / armored and sheathed TYPE P POWER CABLE 600V or 0. control. Construction 1. Bostrig cables have excellent resistance to oil.6/1kV 8 AWG to 777 MCM 1 2 3 5 4 Approvals Applications BostrigTM Type P Marine and Offshore Cable is primarily designed for power. Det Norske Veritas Type Approval Certificates E8792. Listed by ETL per IEEE 1580 (2001). Sheath Soft annealed stranded tinned copper per ASTM B 33. land rigs. Larger diameter cables carry a new flexible design. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 This product is readily available in an unarmored version. abrasion. They are suitable for use in Class I. complying with Type N Neoprene as required in IEEE 1580 (2001). Conductors 2. moisture. A polyester tape separator is used over the conductor. Thickness as shown on data sheet for unarmored version. sunlight. E8795 and E8796. Lloyds Registry of Shipping Approval Certificates No. abrasion. sunlight and ester-based mud (Type P-MR). Bostrig Type P chemically cross-inked polyolefin (XLPO). American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. meeting IEEE 1580 (2001). Braided bronze in accordance with IEEE 1580 (2001).6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. E8793. Flame-retardant Arctic Neoprene applied over the armor. IEEE 1580 (2001). Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. E8794.com .3). ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). moisture. signal and instrumentation applications for offshore.DrakaMOG. Jacket 4. Insulation 3. Armor 5. mud. Features • Superior resistance to oil. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. 140 • 3.3 345 • 1132 528 • 562 •602 11280 • 16786 Inductance Capacitance mH/kft • mH/km pF/ft • pF/m This information is provided for reference only.3 318 • 1043 371 • 411 • 440 6980 • 10387 TPNBS-535 026141 535 • 271.5 .2 2.7 0.060 • 1.505 • 38.465 • 88.3 0.2 0.0 0.6 3.3 247 • 810 267 • 294 • 315 4515 • 6704 TPNBS-313 026138 313 • 158. 2 AWG thru 3/OAWG multiply by 0.04 • 0.5 0.835 • 21.435 • 61.6 3.4 0.Ω/km Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Type Designation Draka Number Conductor Size AWG/MCM • mm2 Sheath Thickness in • mm Cable Diameter (nominal) in • mm TPNBS-8 026126 8 • 7.2 0.3 314 • 1030 469 • 516 • 553 9575 • 14249 TPNBS-777 026143 777 • 393.09 • 0.8 0.1 .18 • 0.09 • 0.0 0.11 • 0.3 0.09 • 0.09 • 0.765 • 70.06 • 0.1OOºC values based on IEEE-45 Table 25 .09 • 0. please consult the factory or your representative to confirm all engineering information. 20 www.110 • 2.975 • 50.2 0.08 • 0.05 • 0.6 3.04 • 0.72.3 153 • 502 86 • 92 • 99 1040 • 1548 TPNBS-3 026130 3 • 25.2 0.3 245 • 804 213 • 218 • 234 3330 • 4955 TPNBS-4/0 026136 4/0 • 112.2 0.10 • 0.110 • 2.09 • 0.1 0.0 0.14 • 0.4 140 • 459 78 • 82 • 88 900 • 1339 TPNBS-4 026129 4 • 21.12 • 0.DrakaMOG.080 • 2.140 • 3.290 • 58.09 • 0.1 0.6 .09 • 0.3 .080 • 2.07 • 0.3 270 • 886 298 • 321 • 344 5170 • 7694 TPNBS-373 026139 373 • 189.6 2.10 • 0.5 .3 187 • 613 111 • 122 • 131 1295 • 1927 TPNBS-1 026132 1 • 46.2 0.2 0.29 • 1.1 0.080 • 2.4 95 • 312 47 • 52 • 56 480 • 714 TPNBS-6 026127 6 • 12.8 1.3 212 • 695 175 • 188 • 201 2500 • 3720 TPNBS-3/0 026135 3/0 • 92.265 • 32.09 • 0.09 • 0.585 • 65.110 • 2. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .04 • 0.0 1.2 1.8 .6 .1 0.3 259 • 850 241 • 252 • 270 3890 • 5789 TPNBS-262 026137 262 • 133.3 178 • 584 137 • 143 • 153 1850 • 2753 TPNBS-1/0 026133 1/0 • 56.110 • 53.5 0.275 • 83.0 .6 0.125 • 3.09 • 0. 4/0 AWG thru 1000 MCM multiply by O.125 • 3.1 0.12 • 0.5 .6 .125 • 3.2 0.9 0.8 1.1 0.2 .140 • 3.080 • 2.10 • 0.Bostrig Type P 0807 Page 6 of 62 BOSTRIG™ TYPE P POWER CABLE three conductor / armored and sheathed 8 AWG to 777 MCM / 600V or 0.1 0. This information is not meant to replace the information in the appropriate and applicable standard or code.200 • 30.3 291 • 954 417 • 443 • 475 8235 • 12255 TPNBS-646 026142 646 • 327.030 • 77.5 0.140 • 29.66.5 .080 • 2.1 .6/1kV Impedance (Phase-Neutral) Ω/kft .23 • 0.0 .2 2.5 0.57 .0 1.com .09 • 0.0 1.6 2.6 2.6 .2 0.7 .0 1.5 0.0 0.140 • 3.3 0.11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature.9 0.8 1.965 • 24.140 • 3.1 .46 • 1.09 • 0.70 • 2.620 • 41.730 • 43.120 • 28.11 • 0.5 .04 • 0.3 292 • 958 333 • 361 • 387 5975 • 8892 TPNBS-444 026140 444 • 225.3 .3 173 • 567 99 • 108 • 116 1160 • 1726 TPNBS-2 026131 2 • 30.03 • 0.2 0.6 0.33 • 1. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.4 126 • 413 63 • 70 • 75 700 • 1042 TPNBS-5 026128 5 • 18.64.140 • 3.3 190 • 623 156 • 164 • 176 2190 • 3259 TPNBS-2/0 026134 2/0 • 66. sunlight. meeting IEEE 1580 (2001). E8795 and E8796.6/1kV Four conductor / unarmored TYPE P POWER CABLE 600V or 0. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. TM This product is readily available in an armored and sheathed version. Bostrig cables have excellent resistance to oil. moisture. complying with Type N Neoprene as required in IEEE-1580 (2001). A polyester tape separator is used over the conductor. moisture. Category A.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Jacket Soft annealed stranded tinned copper per ASTM B 33. 0. Flame-retardant Arctic Neoprene. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 Construction 1. signal and instrumentation applications for offshore. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. abrasion. Listed by ETL per IEEE 1580 (2001). Lloyds Registry of Shipping Approval Certificates No. marine vessels and oil and gas drilling rigs. E8793. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. mud. Larger diameter cables carry a new flexible design.Bostrig Type P 0807 Page 31 of 62 BOSTRIG™ TYPE P POWER CABLE 600V OR 0. Features • Superior resistance to oil. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). abrasion.com . UL 1309/CSA 245 and IEEE 45 (1998) for 600V. land rigs. control. E8794.3).6/1kV 8 AWG to 777 MCM 1 2 3 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. Conductors 2. Det Norske Veritas Type Approval Certificates E8792. Insulation 3. IEEE 1580 (2001).DrakaMOG. 21 www. crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0. Thickness as shown in tables on opposite page. sunlight and ester-based mud (Type P-MR).2 No. UL 1309/CSA245 and the performance requirements of IEC 60092-3. Bostrig Type P chemically cross-inked polyolefin (XLPO). 110 • 2.7 .140 • 3.3 270 • 886 298 • 321 • 344 5475 • 8148 FPN-373 026092 373 • 189. 22 www.6 0.6 2.5 0.10 • 0.060 • 1.3 247 • 810 267 • 294 • 315 4640 • 6905 FPN-313 026091 313 • 158.125 • 3.04 • 0.1 0.3 291 • 954 417 • 443 • 475 8970 • 13349 FPN-646 026095 646 • 327.3 0.0 .160 • 29.4 95 • 312 47 • 52 • 56 350 • 521 FPN-6 026080 6 • 12.0 1.5 .165 • 55.11 • 0.4 126 • 413 63 • 70 • 75 540 • 804 FPN-5 026081 5 • 18.07 • 0.510 • 38.3 190 • 623 156 • 164 • 176 2100 • 3125 FPN-2/0 026087 2/0 • 66. If all conductors are current carrying.140 • 3.3 0.2 0.5 .140 • 3.1 0.3 318 • 1043 371 • 411 • 440 7500 • 11161 FPN-535 026094 535 • 271.140 • 3.3 .695 • 68.12 • 0.4 140 • 459 78 • 82 • 88 775 • 1153 FPN-4 026082 4 • 21.09 • 0.14 • 0.1 0.080 • 2.125 • 3.46 • 1.4 0.3 245 • 804 213 • 218 • 234 3360 • 5000 FPN-4/0 026089 4/0 • 112.0 0.3 173 • 567 99 • 108 • 116 1025 • 1525 FPN-2 026084 2 • 30.09 • 0.Bostrig Type P 0807 Page 32 of 62 BOSTRIG™ TYPE P POWER CABLE four conductor / unarmored 8 AWG to 777 MCM / 600V or 0.09 • 0.6 3.9 0.2 .04 • 0.09 • 0.DrakaMOG.3 0.980 • 24.1 .445 • 87.09 • 0.com .2 1.990 • 76.060 • 1.6 2.8 1.2 2.5 .09 • 0.125 • 3.1 0.09 • 0.8.8 0.3 187 • 613 111 • 122 • 131 1170 • 1741 FPN-1 026085 1 • 46.820 • 20.080 • 2.5 0.05 • 0.57 .8 0.11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature.8 1.3 212 • 695 175 • 188 • 201 2410 • 3586 FPN-3/0 026088 3/0 • 92.1 0.3 292 • 958 333 • 361 • 387 6365 • 9472 FPN-444 026093 444 • 225.2 1.12 • 0.2 0.525 • 64.5 .29 • 1.590 • 40.995 • 50.8 .3 178 • 584 137 • 143 • 153 1710 • 2545 FPN-1/0 026086 1/0 • 56.080 • 2.04 • 0. The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor.64.5 0.875 • 47.020 • 25.23 • 0.5 .9 0.11 • 0.08 • 0.5 0.10 • 0.18 • 0.09 • 0.4 0.6 2.03 • 0.6 3.09 • 0.140 • 3. This information is not meant to replace the information in the appropriate and applicable standard or code.5 0. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .1 . 4/0 AWG thru 1000 MCM multiply by O.70 • 2.09 • 0.690 • 17.09 • 0.080 • 2.72.0 0.0 0.09 • 0.3 153 • 502 86 • 92 • 99 885 • 1317 FPN-3 026083 3 • 25.0 1.66.3 345 • 1132 528 • 562 • 602 12730 • 18944 Type Designation Inductance Capacitance mH/kft • mH/km pF/ft • pF/m This information is provided for reference only.3 314 • 1030 469 • 516 • 553 10640 • 15834 FPN-777 026096 777 • 393.360 • 34.6 . the ampacity must be reduced by 0.110 • 2.140 • 3.6/1kV Impedance (Phase-Neutral) Ω/kft .6 .33 • 1.2 0.4 0.0 1.080 • 2.1 0. 2 AWG thru 3/OAWG multiply by 0.5 .3 259 • 850 241 • 252 • 270 3940 • 5863 FPN-262 026090 262 • 133.06 • 0.5 0.1 0.3 .8 0.7 0.04 • 0.1OOºC values based on IEEE-45 Table 25 .4 0.0 0.6 0.0 . Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.6 .10 • 0.5 0.6 2.1 .6 .Ω/km Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Draka Number Conductor Size AWG/MCM • mm2 Jacket Thickness in • mm Cable Diameter (nominal) in • mm FPN-8 026079 8 • 7.355 • 59.0 1.230 • 82.080 • 27.09 • 0. please consult the factory or your representative to confirm all engineering information. sunlight and ester-based mud (Type P-MR). E8793. Bostrig cables have excellent resistance to oil. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. abrasion. Construction 1. Features • Superior resistance to oil. A polyester tape separator is used over the conductor. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. Larger diameter cables carry a new flexible design. Bostrig Type P cables complywith the Crush and Impact requirements of UL 2225. abrasion. 23 www. Det Norske Veritas Type Approval Certificates E8792. 0. They are suitable for use in Class I. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Category A. Lloyds Registry of Shipping Approval Certificates No.6/1kV Four conductor / armored and sheathed TYPE P POWER CABLE 600V or 0. Listed by ETL per IEEE 1580 (2001). marine vessels and oil and gas drilling rigs.2 No. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 This product is readily available in an unarmored version. Flame-retardant Arctic Neoprene applied over the armor. Sheath Soft annealed stranded tinned copper per ASTM B 33. E8794. TM The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Jacket 4. mud.6/1kV 8 AWG to 777 MCM 1 2 3 5 4 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Bostrig Type P chemically cross-inked polyolefin (XLPO). moisture.com . Braided bronze in accordance with IEEE 1580 (2001). land rigs. complying with Type N Neoprene as required in IEEE 1580 (2001). IEEE 1580 (2001). control. complying with Type N Neoprene as required in IEEE-1580 (2001). Conductors 2.DrakaMOG.3). UL 1309/CSA245 and the performance requirements of IEC 60092-3. signal and instrumentation applications for offshore.Bostrig Type P 0807 Page 7 of 62 BOSTRIG™ TYPE P POWER CABLE 600V OR 0. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0. sunlight. moisture. Armor 5. Thickness as shown in tables on opposite page. E8795 and E8796. Thickness as shown on data sheet for unarmored version. Flame-retardant Arctic Neoprene. Insulation 3. meeting IEEE 1580 (2001). 7 0.080 • 2.5 0.6 3.2 0.0 .3 0.3 .6 .5 .3 178 • 584 137 • 143 • 153 2300 • 3423 FPNBS-1/0 026151 1/0 • 56.12 • 0.5 0.5 .Bostrig Type P 0807 Page 8 of 62 BOSTRIG™ TYPE P POWER CABLE four conductor / armored and sheathed 8 AWG to 777 MCM / 600V or 0.05 • 0.10 • 0.4 95 • 312 47 • 52 • 56 605 • 900 FPNBS-6 026145 6 • 12.1 0.140 • 3. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .2 0.3 0.2 0.06 • 0.1 0.3 190 • 623 156 • 164 • 176 2860 • 4256 FPNBS-2/0 026152 2/0 • 66.57 .110 • 2.10 • 0.5 .0 0.18 • 0. 2 AWG thru 3/OAWG multiply by 0.6 3.66.8 .140 • 3.2 2.8 1.8.640 • 41.23 • 0.060 • 1.1OOºC values based on IEEE-45 Table 25 .4 0.210 • 30.10 • 0.09 • 0.5 0.2 0. 24 www.1 0.6 2.6 3.815 • 96.04 • 0.6 0.04 • 0.1 0.3 291 • 954 417 • 443 • 475 10500 • 15626 FPNBS-646 026160 646 • 327.3 245 • 804 213 • 218 • 234 4220 • 6280 FPNBS-4/0 026154 4/0 • 112.6 0.5 0.3 212 • 695 175 • 188 • 201 3150 • 4688 FPNBS-3/0 026153 3/0 • 92.3 .895 • 73.4 0.29 • 1.0 1. please consult the factory or your representative to confirm all engineering information.3 0. The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor.065 • 77. 4/0 AWG thru 1000 MCM multiply by O.080 • 2.110 • 2.09 • 0.3 259 • 850 241 • 252 • 270 4920 • 7322 FPNBS-262 026155 262 • 133.7 0.46 • 1.0 1.09 • 0.10 • 0.9 0.6 0.14 • 0.9 0.910 • 23.8 0.820 • 46.2 .09 • 0.0 0.8 0.110 • 2. This information is not meant to replace the information in the appropriate and applicable standard or code.080 • 2.4 173 • 567 99 • 108 • 116 1415 • 2106 FPNBS-2 026149 2 • 30.6 .11 • 0. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.33 • 1. If all conductors are current carrying.70 • 2.440 • 36.335 • 59.09 • 0.3 270 • 886 298 • 321 • 344 6620 • 9852 FPNBS-373 026157 373 • 189.600 • 91.1 0.1 .5 .6 3.7 .4 140 • 459 78 • 82 • 88 1140 • 1696 FPNBS-4 026147 4 • 21.com .300 • 33.Ω/km Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Type Designation Draka Number Conductor Size AWG/MCM • mm2 Sheath Thickness in • mm FPNBS-8 026144 8 • 7.1 .3 247 • 810 267 • 294 • 315 5700 • 8483 FPNBS-313 026156 313 • 158.5 0.6 2.6 .2 2.09 • 0.3 0.140 • 3.08 • 0.6/1kV Cable Diameter (nominal) in • mm Impedance (Phase-Neutral) Ω/kft .125 • 3.09 • 0.185 • 55.045 • 26.2 2.125 • 3.11 • 0.3 0.1 .04 • 0.3 187 • 613 111 • 122 • 131 1675 • 2493 FPNBS-1 026150 1 • 46.920 • 48.080 • 2.DrakaMOG.360 • 85.1 0.505 • 63.04 • 0.125 • 3. the ampacity must be reduced by 0.04 • 0.5 0.3 292 • 958 333 • 361 • 387 7590 • 11295 FPNBS-444 026158 444 • 225.3 314 • 1030 469 • 516 • 553 12290 • 18290 FPNBS-777 026161 777 • 393.4 126 • 413 63 • 70 • 75 890 • 1324 FPNBS-5 026146 5 • 18.1 0.140 • 3.72.11 • 0.8 1.64.10 • 0.3 345 • 1132 528 • 562 • 602 14500 • 21578 Inductance Capacitance mH/kft • mH/km pF/ft • pF/m This information is provided for reference only.3 318 • 1043 371 • 411 • 440 8800 • 13096 FPNBS-535 026159 535 • 271.12 • 0.140 • 3.080 • 2.0 1.8 1.6 .140 • 3.5 .07 • 0.0 1.13 • 0.4 153 • 502 86 • 92 • 99 1265 • 1883 FPNBS-3 026148 3 • 25.09 • 0.5 0.0 1.240 • 31.695 • 68.09 • 0.11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature. moisture.com . crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0. land rigs.DrakaMOG. signal and instrumentation applications for offshore. control. Features • Superior resistance to oil. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. abrasion. moisture. 0. abrasion. Bostrig cables have excellent resistance to oil. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). Insulation 3. mud. 25 www. meeting IEEE 1580 (2001). IEEE 1580 (2001). E8793. A polyester tape separator is used over the conductor. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. sunlight. Bostrig Type P chemically cross-inked polyolefin (XLPO).3). Flame-retardant Arctic Neoprene. complying with Type N Neoprene as required in IEEE-1580 (2001). TM This product is readily available in an armored and sheathed version. Category A. marine vessels and oil and gas drilling rigs. UL 1309/CSA245 and the performance requirements of IEC 60092-3. Thickness as shown in tables on opposite page. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Jacket Soft annealed stranded tinned copper per ASTM B 33. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. E8794.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Lloyds Registry of Shipping Approval Certificates No. Listed by ETL per IEEE 1580 (2001). Det Norske Veritas Type Approval Certificates E8792. Larger diameter cables carry a new flexible design. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 Construction 1.6/1kV Five conductor / unarmored TYPE P POWER CABLE 600V or 0.Bostrig Type P 0807 Page 35 BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV 8 to 4/0 AWG 1 2 3 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power.2 No. E8795 and E8796. Conductors 2. sunlight and ester-based mud (Type P-MR). 0 1.8 0.280 • 32.8 1. 4/0 AWG thru 1000 MCM multiply by O. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .7 .8 1.3 0.2 0.080 • 2.3 187 • 613 89 • 98 • 105 1450 • 2158 QPN-1 026103 1 • 46.12 • 0.4 0.0 1.2 1.140 • 3.080 • 27.3 0.3 0.09 • 0.1OOºC values based on IEEE-45 Table 25 .3 212 • 695 140 • 150 • 161 3015 • 4487 QPN-3/0 026106 3/0 • 92.09 • 0.14 • 0.10 • 0. 26 www.1 .com .790 • 45.6/1kV Cable Diameter (nominal) in • mm Impedance (Phase-Neutral) Ω/kft .060 • 1. please consult the factory or your representative to confirm all engineering information.6 2.3 245 • 804 170 • 174 • 187 4140 • 6161 QPN-4/0 026107 4/0 • 112.11 • 0.5 .5 0.8 0.66.0 0.33 • 1.4 95 • 312 38 • 42 • 45 430 • 640 QPN-6 026098 6 • 12.4 126 • 413 50 • 56 • 60 700 • 1042 QPN-5 026099 5 • 18.5 760 • 19.6 0.195 • 30.6 2.4 140 • 459 62 • 66 • 70 950 • 1414 QPN-4 026100 4 • 21.64.3 178 • 584 110 • 114 • 122 2205 • 3282 QPN-1/0 026104 1/0 • 56.09 • 0.DrakaMOG. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.Ω/km Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Draka Number Conductor Size AWG/MCM • mm2 Jacket Thickness in • mm QPN-8 026097 8 • 7.210 • 56.6 0.565 • 39.5 0. 2 AWG thru 3/OAWG multiply by 0.3 .715 • 43.125 • 3.46 • 1.5 .12 • 0.18 • 0.6 .70 • 2.1 .2 1.09 • 0.5 0.110 • 2.11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature.3 0.6 .3 153 • 502 69 • 74 • 79 1100 • 1637 QPN-3 026101 3 • 25.4 0.09 • 0.955 • 24.5 .125 • 3.110 • 2.11 • 0. This information is not meant to replace the information in the appropriate and applicable standard or code.6 0.3 259 • 850 193 • 202 • 216 4850 • 7218 Type Designation Inductance Capacitance mH/kft • mH/km pF/ft • pF/m This information is provided for reference only.1 0.07 • 0.140 • 3.57 .23 • 0.075 • 52.080 • 2.125 • 3.72.0 .3 0.09 • 0.4 0.080 • 2.7 0.1 0.Bostrig Type P 0807 Page 36 BOSTRIG™ TYPE P POWER CABLE five conductor / unarmored 8 to 4/0 AWG / 600V or 0.3 190 • 623 125 • 131 • 141 2650 • 3945 QPN-2/0 026105 2/0 • 66.10 • 0.3 173 • 567 79 • 86 • 93 1260 • 1875 QPN-2 026102 2 • 30.6 .08 • 0.125 • 28.29 • 1.5 0.10 • 0.2 1. abrasion. marine vessels and oil and gas drilling rigs. E8795 and E8796. sunlight. control. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Thickness as shown on data sheet for unarmored version.3). IEEE 1580 (2001). 27 www. Larger diameter cables carry a new flexible design.Bostrig Type P 0807 Page 9 of 62 BOSTRIG™ TYPE P POWER CABLE 600V OR 0. meeting IEEE 1580 (2001). A polyester tape separator is used over the conductor. Listed by ETL per IEEE 1580 (2001). E8793. Features • Superior resistance to oil. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J105 This product is readily available in an unarmored version. land rigs. abrasion.6/1kV Five conductor / armored and sheathed TYPE P POWER CABLE 600V or 0. crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0.com . Thickness as shown in tables on opposite page. Jacket 4. moisture. complying with Type N Neoprene as required in IEEE-1580 (2001). UL 1309/CSA245 and the performance requirements of IEC 60092-3.DrakaMOG. sunlight and ester-based mud (Type P-MR). moisture. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. TM The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Armor 5. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. Flame-retardant Arctic Neoprene applied over the armor. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. signal and instrumentation applications for offshore. Flame-retardant Arctic Neoprene. Bostrig cables have excellent resistance to oil. complying with Type N Neoprene as required in IEEE 1580 (2001). mud. 0. Det Norske Veritas Type Approval Certificates E8792.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Sheath Soft annealed stranded tinned copper per ASTM B 33. Insulation 3. E8794. Bostrig Type P chemically cross-inked polyolefin (XLPO). Category A. Lloyds Registry of Shipping Approval Certificates No. They are suitable for use in Class I. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). Conductors 2. Construction 1.6/1kV 8 to 4/0 AWG 1 2 3 5 4 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. Braided bronze in accordance with IEEE 1580 (2001). 0 1.140 • 3.3 187 • 613 89 • 98 • 105 2000 • 2976 QPNBS-1 026168 1 • 46.3 190 • 623 125 • 131 • 141 3435 • 5112 QPNBS-2/0 026170 2/0 • 66. 28 www.1 0.11 • 0.4 0.3 245 • 804 170 • 174 • 187 5150 • 7664 QPNBS-4/0 026172 4/0 • 112.3 .64.175 • 29.1OOºC values based on IEEE-45 Table 25 .9 0.4 140 • 459 62 • 66 • 70 1350 • 2009 QPNBS-4 026165 4 • 21.5 0.080 • 2.2 2.12 • 0.70 • 2.10 • 0.6 2. 2 AWG thru 3/OAWG multiply by 0.5 .10 • 0.3 0.08 • 0.09 • 0. This information is not meant to replace the information in the appropriate and applicable standard or code.110 • 2.875 • 47.11 • 0.120 • 53.0 .140 • 3.3 0.23 • 0.3 212 • 695 140 • 150 • 161 3830 • 5700 QPNBS-3/0 026171 3/0 • 92.345 • 34.18 • 0.com .11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature.3 178 • 584 110 • 114 • 122 2930 • 4360 QPNBS-1/0 026169 1/0 • 56.475 • 37.2 0.4 173 • 567 79 • 86 • 93 1775 • 2642 QPNBS-2 026167 2 • 30.1 .10 • 0.9 0.1 .6 2. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .14 • 0.6 0.415 • 61.09 • 0.6 .10 • 0.080 • 2.Bostrig Type P 0807 Page 10 of 62 BOSTRIG™ TYPE P POWER CABLE five conductor / armored and sheathed 8 to 4/0 AWG / 600V or 0.3 259 • 850 193 • 202 • 216 5930 • 8825 Inductance Capacitance mH/kft • mH/km pF/ft • pF/m This information is provided for reference only.8 0.6/1kV Cable Diameter (nominal) in • mm Impedance (Phase-Neutral) Ω/kft .0 1.2 0.3 0.2 0.12 • 0.0 1.310 • 33.125 • 3.4 0. 4/0 AWG thru 1000 MCM multiply by O.560 • 39.125 • 3.6 .080 • 2.10 • 0.2 2.4 126 • 413 50 • 56 • 60 1045 • 1555 QPNBS-5 026164 5 • 18.8 1.2 1.7 .4 153 • 502 69 • 74 • 79 1510 • 2247 QPNBS-3 026166 3 • 25.Ω/km Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Type Designation Draka Number Conductor Size AWG/MCM • mm2 Sheath Thickness in • mm QPNBS-8 026162 8 • 7.5 .29 • 1.5 0.125 • 3.4 95 • 312 38 • 42 • 45 710 • 1057 QPNBS-6 026163 6 • 12.5 .550 • 64. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.33 • 1.57 .11 • 0.110 • 2.8 1.07 • 0.66.0 0.8 0.025 • 51.3 0.DrakaMOG.6 0.9 0.6 0.13 • 0. please consult the factory or your representative to confirm all engineering information.5 0.080 • 2.72.6 .46 • 1.980 • 24. complying with Type N Neoprene as required in IEEE-1580 (2001). IEEE 1580 (2001). moisture. moisture. Flame-retardant Arctic Neoprene applied over the armor.Bostrig Type P 0807 Page 51 of 62 BOSTRIG™ TYPE P SIGNAL CABLE 600V Overall shielded multiconductor / armored and sheathed TYPE P SIGNAL CABLE 600V 1 2 3 4 5 20. control. Conductors 2. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. An aluminum/polyester tape with drain wire. meeting IEEE 1580 (2001). Thickness as shown in tables on opposite page. 100% coverage. Sheath Soft annealed stranded tinned copper per ASTM B 33.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. 18 & 16 AWG 6 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. Bostrig Type P chemically cross-inked polyolefin (XLPO). Det Norske Veritas Type Approval Certificates E8792. 95/00161 (E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured tc BIW Specifying Standard J106 Construction 1.3). ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). 29 www. land rigs. E8795 and E8796. Thickness as shown on data sheet for unarmored version. A tape separator is used over the conductor. Bostrig cables have excellent resistance to oil. Lloyds Registry of Shipping Approval Certificates No. Category A. UL 1309/CSA 245 and IEEE 45 (1998) for 600V.com . Insulation 3.2 No. Flame-retardant Arctic Neoprene. 0. signal and instrumentation applications for offshore. UL1309/CSA245 and the performance requirements of IEC 60092-3. sunlight. marine vessels and oil and gas drilling rigs. Jacket 5 Armor 6. crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0. is applied over the cabled core. complying with Type N Neoprene as required in IEEE 1580 (2001). Features • Superior resistance to oil. abrasion. TM This product is readily available in an unarmored version. abrasion. E8793. E8794. Shield 4. Braided bronze in accordance with IEEE 1580 (2001). mud. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Larger diameter cables carry a new flexible design. sunlight and ester-based mud (Type P-MR).DrakaMOG. Listed by ETL per IEEE 1580 (2001). 8 230 • 342 C(0S)20PNBS-6 026506 6 19/32 .060 • 1.060 • 1.060 • 1.030 • 0.5 .030 • 0.060 • 1.564 • 14.6 259 • 389 C(0S)18PNBS-6 026510 6 19/30 .5 231 • 344 C(0S)18PNBS-5 026509 5 19/30 .345 • 16.76 .7 205 • 305 C(0S)18PNBS-4 026508 4 19/30 .9 313 • 466 12 19/29 .5 . 18 & 16 AWG / 600V 20 AWG • 0.com .030 • 0.5 .569 • 14. 30 www.030 • 0.DrakaMOG.060 • 1.8 470 • 699 Type Designation 18 AWG • 0.76 .76 .76 .1 283 • 421 C(0S)16PNBS-6 026514 6 19/29 .030 • 0.76 .586 • 14.2 210 • 313 C(0S)20PNBS-5 026505 5 19/32 .060 • 1.4 286 • 426 25 19/30 .633 • 16.23 mm2 Type Designation C(0S)16PNBS-12 This information is provided for reference only.060 • 1.584 • 14.557 • 14.76 .3 221 • 329 C(0S)16PNBS-4 026512 4 19/29 .76 .060 • 1.030 • 0.5 185 • 275 C(0S)20PNBS-4 026504 4 19/32 .76 .613 • 15.030 • 0.5 .76 .5 .030 • 0.030 • 0.3 705 • 1049 Draka Number Number of Conductors Stranding Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km C(0S)16PNBS-3 026511 3 19/29 .61 mm2 Draka Number Number of Conductors Stranding Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km C(0S)20PNBS-3 026503 3 19/32 .820 • 20.5 .060 • 1.96 mm2 Type Designation C(0S)18PNBS-25 16 AWG • 1.76 .030 • 0.060 • 1.6 255 • 380 Draka Number Number of Conductors Stranding Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km C(0S)18PNBS-3 026507 3 19/30 .060 • 1.5 .Bostrig Type P 0807 Page 52 of 62 BOSTRIG™ TYPE P SIGNAL CABLE overall shielded multiconductor / armored and sheathed 20.8 242 • 360 C(0S)16PNBS-5 026513 5 19/29 .76 .76 . please consult the factory or your representative to confirm all engineering information.030 • 0.5 .030 • 0.5 .76 .5 .5 .060 • 1.030 • 0.030 • 0.060 • 1.614 • 15.5 .540 • 13.666 • 16.060 • 1.5 1.074 • 27.76 . This information is not meant to replace the information in the appropriate and applicable standard or code.533 • 13.5 . 6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Category A. signal and instrumentation applications for offshore. Jacket Soft annealed stranded tinned copper per ASTM B 33. Thickness as shown in tables on opposite page. Features • Superior resistance to oil. control. mud. An aluminum/polyester tape with drain wire. Insulation 3. Bostrig Type P chemically cross-inked polyolefin (XLPO). E8793. complying with Type N Neoprene as required in IEEE-1580 (2001).Bostrig Type P 0807 Page 49 of 62 BOSTRIG™ TYPE P SIGNAL CABLE 600V Overall shielded multiconductor / unarmored TYPE P SIGNAL CABLE 600V 1 2 3 20. 18 & 16 AWG 4 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power.2 No.3). 0. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. moisture. 31 www. Lloyds Registry of Shipping Approval Certificates No. UL 1309/CSA 245 and IEEE 45 (1998) for 600V & 2000V. A polyester tape separator is used over the conductor. abrasion. sunlight and ester-based mud (Type P-MR). 95/00161 (E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured tc BIW Specifying Standard J106 Construction 1. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Flame-retardant Arctic Neoprene. meeting IEEE 1580 (2001). Shield 4. Det Norske Veritas Type Approval Certificates E8792. Larger diameter cables carry a new flexible design. marine vessels and oil and gas drilling rigs. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). The single pair construction has only the overall shield. crush and impact • Super-flexible at 4/0 AWG and larger • Meets IEEE standards for 600V / IEC standards for 0.DrakaMOG. TM This product is readily available in an armored version. IEEE 1580 (2001). abrasion. is applied over each twisted pair and the cabled core. UL1309/CSA245 and the performance requirements of IEC 60092-3. Bostrig cables have excellent resistance to oil. land rigs. E8795 and E8796. E8794. moisture. sunlight. Listed by ETL per IEEE 1580 (2001).com . Conductors 2. 100% coverage. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. 358 • 9.386 • 9.060 • 1.4 150 • 223 C(0S)16PN-12 027052 12 19/29 .76 .5 .96 mm2 Type Designation Draka Number C(0S)18PN-3 3 19/30 .1 C(0S)18PN-4 026496 4 19/30 .488 • 12.030 • 0.060 • 1.030 • 0.5 .467 • 11.76 .2 92 • 137 C(0S)20PN-6 026494 6 19/32 .060 • 1.76 .76 .030 • 0.030 • 0.61 mm2 Draka Number Number of Conductors Stranding Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm C(0S)20PN-3 026491 3 19/32 .9 107 • 159 Number of Conductors Stranding Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km 78 • 116 Type Designation Cable Weight (approximate) Lbs/mft • Kg/km 18 AWG • 0.8 92 • 137 C(0S)18PN-5 026497 5 19/30 .060 • 1.5 .2 395 • 588 Draka Number Number of Conductors Stranding Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km C(0S)16PN-3 030645 3 19/29 .8 65 • 97 C(0S)20PN-4 026492 4 19/32 .060 • 1. This information is not meant to replace the information in the appropriate and applicable standard or code.060 • 1.431 • 10.030 • 0.5 .5 .5 .030 • 0.060 • 1. 32 www.76 .5 .385 • 9.5 .060 • 1.2 104 • 155 C(0S)16PN-5 026501 5 19/29 .76 .Bostrig Type P 0807 Page 50 of 62 BOSTRIG™ TYPE P SIGNAL CABLE overall shielded multiconductor / unarmored 20.DrakaMOG.6 130 • 193 C(0S)16PN-6 026502 6 19/29 .76 .060 • 1.795 • 20.030 • 0.0 113 • 168 C(0S)18PN-6 026498 6 19/30 .030 • 0.060 • 1.060 • 1.060 • 1.030 • 0.23 mm2 Type Designation This information is provided for reference only.5 .030 • 0.5 . 18 & 16 AWG / 600V 20 AWG • 0.060 • 1.5 .com . please consult the factory or your representative to confirm all engineering information.060 • 1.8 88 • 131 C(0S)16PN-4 026500 4 19/29 .76 .5 81 • 121 C(0S)20PN-5 026493 5 19/32 .9 260 • 387 C(0S)18PN-25 16 AWG • 1.76 .5 .9 130 • 193 25 19/30 .76 .030 • 0.373 • 9.455 • 11.400 • 10.345 • 8.403 • 10.76 .5 .030 • 0.435 • 11.625 • 15.76 .5 .76 .030 • 0.030 • 0.76 . crush and impact • Meets IEEE standards for 600V / IEC standards for 0. Insulation 3. moisture. meeting IEEE 1580 (2001). An aluminum/polyester tape with drain wire. A polyester tape separator is used over the conductor.3). Features • Superior resistance to oil. 33 www. Bostrig Type P chemically cross-inked polyolefin (XLPO). Jacket Soft annealed stranded tinned copper per ASTM B 33. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. marine vessels and oil and gas drilling rigs. Flame-retardant Arctic Neoprene. E8794. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). signal and instrumentation applications for offshore. 95/00161 (E3) and 95-00162(E3) Manufactured tc BIW Specifying Standard J106 Construction 1. complying with Type N Neoprene as required in IEEE-1580 (2001). E8795 and E8796.6/1kV 1 2 3 16 & 14 AWG 4 Applications Approvals BostrigTM Type P Marine and Offshore Cable is primarily designed for power. land rigs. UL1309/CSA245 and the performance requirements of IEC 60092-3. Category A.2 No.Bostrig Type P 0807 Page 45 of 62 BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0. Bostrig cables have excellent resistance to oil. Transport Canada Approved AMS400-20-2 Lloyds Registry of Shipping Approval Certificates No. IEEE 1580 (2001).com . abrasion. The single pair construction has only the overall shield. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. moisture.6/1kV Individual and overall shielded multipair / unarmored TYPE P SIGNAL CABLE 600V or 0. control. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. sunlight and ester-based mud (Type P-MR).DrakaMOG. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Shield 4. Det Norske Veritas Type Approval Certificates E8792. mud. Thickness as shown in tables on opposite page. is applied over each twisted pair and the cabled core.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. sunlight. 100% coverage. abrasion. Larger diameter cables carry a new flexible design. This product is readily available in an armored and sheathed version. Listed by ETL per IEEE 1580 (2001). E8793. Conductors 2. 0. 7 240 • 357 TP(I/S-0S)16PN-5 026368 5 .030 • 0.76 .0 475 • 707 TP(I/S-0S)16PN-10 026372 10 .4 475 • 707 TP(I/S-0S)14PN-8 026384 8 .620 • 15.76 .060 • 1.065 • 27.76 .0 1.300 • 33.76 .76 .1 320 • 476 TP(I/S-0S)16PN-7 026370 7 .030 • 0.6 170 • 253 TP(I/S-0S)16PN-3 026366 3 .0 .805 • 20.060 • 1.6 760 • 1131 TP(I/S-0S)14PN-16 026387 16 .7 510 • 759 TP(I/S-0S)16PN-12 026373 12 .080 • 2.030 • 0.030 • 0.76 .1 585 • 871 TP(I/S-0S)16PN-16 026374 16 .805 • 20.030 • 0.0 1.080 • 2.030 • 0.76 .94 mm2 Type Designation This information is provided for reference only.8 1.76 .080 • 2.030 • 0.060 • 1.030 • 0.5 .76 .76 .305 • 33.76 .76 .5 .76 .740 • 18.com .0 .0 . please consult the factory or your representative to confirm all engineering information.030 • 0.8 1.76 .030 • 0.060 • 1.695 • 17.5 .0 1.6 1165 • 1734 Draka Number Number of Pairs Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km TP(0S)14PN-1 026377 1 .1 345 • 513 TP(I/S-0S)16PN-8 026371 8 .5 .030 • 0.76 .4 450 • 670 TP(I/S-0S)14PN-7 026383 7 .030 • 0.030 • 0.0 975 • 1451 TP(I/S-0S)14PN-20 026388 20 .520 • 38. This information is not meant to replace the information in the appropriate and applicable standard or code.060 • 1.110 • 2.080 • 2.3 235 • 350 TP(I/S-0S)14PN-4 026380 4 .0 1.395 • 10.76 .670 • 42.060 • 1.350 • 8.76 .76 .5 .110 • 2.0 85 • 126 TP(I/S-0S)14PN-2 026378 2 .070 • 27.665 • 16.810 • 20.0 1.060 • 1.920 • 23.76 .DrakaMOG.080 • 2.8 275 • 409 TP(I/S-0S)16PN-6 026369 6 .030 • 0.030 • 0.650 • 19.5 .985 • 25.110 • 2.2 915 • 1362 TP(I/S-0S)16PN-24 026376 24 .640 • 16.4 1515 • 2255 Type Designation Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km 14 AWG • 1.030 • 0.5 .9 65 • 97 TP(I/S-0S)16PN-2 026365 2 .2 635 • 945 TP(I/S-0S)14PN-12 026386 12 .76 .060 • 1.680 • 17.060 • 1.76 .0 1.0 1.185 • 30.5 .490 • 37.030 • 0. 34 www.080 • 2.080 • 2.080 • 2.030 • 0.030 • 0.23 mm2 Draka Number Number of Pairs Insulation Thickness in • mm Sheath Thickness in • mm TP(0S)16PN-1 026364 1 .030 • 0.030 • 0.165 • 29.030 • 0.080 • 2.Bostrig Type P 0807 Page 46 of 62 BOSTRIG™ TYPE P SIGNAL CABLE individual and overall shielded multipair / unarmored and sheathed 16 & 14 AWG / 600V or 0.5 .76 .1 290 • 432 TP(I/S-0S)14PN-5 026381 5 .030 • 0.3 180 • 268 TP(I/S-0S)14PN-3 026379 3 .76 .6/1kV 16 AWG • 1.3 540 • 804 TP(I/S-0S)14PN-10 026385 10 .1 750 • 1116 TP(I/S-0S)16PN-20 026375 20 .030 • 0.010 • 25.5 .920 • 23.080 • 2.9 215 • 320 TP(I/S-0S)16PN-4 026367 4 .995 • 25.8 1.6 345 • 513 TP(I/S-0S)14PN-6 026382 6 .76 .0 .030 • 0.5 .060 • 1.030 • 0.060 • 1.080 • 2.76 .76 .5 .9 1280 • 1905 TP(I/S-0S)14PN-24 026389 24 .060 • 1. moisture.Bostrig Type P 0807 Page 21 of 62 BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0. UL 1309/CSA245 and the performance requirements of IEC 60092-3. Thickness as shown in tables on opposite page. abrasion. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. They are suitable for use in Class I. sunlight and ester-based mud (Type P-MR).com . sunlight.3). Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. Bostrig cables have excellent resistance to oil. Thickness as shown on data sheet for unarmored version. E8794. Bostrig Type P chemically cross-inked polyolefin (XLPO). IEEE 1580 (2001). marine vessels and oil and gas drilling rigs. The single pair construction has only the overall shield. land rigs. Det Norske Veritas Type Approval Certificates E8792. Braided bronze in accordance with IEEE 1580 (2001). moisture. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J106 This product is readily available in an unarmored version. Conductors 2. 100% coverage.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. 35 www. is applied over each twisted pair and the cabled core. Shield 4. 0. signal and instrumentation applications for offshore. E8793. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. Insulation 3. A polyester tape separator is used over the conductor. Larger diameter cables carry a new flexible design. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. complying with Type N Neoprene as required in IEEE-1580 (2001). complying with Type N Neoprene as required in IEEE 1580 (2001).DrakaMOG. E8795 and E8796. Flame-retardant Arctic Neoprene applied over the armor. Lloyds Registry of Shipping Approval Certificates No. Category A. mud. abrasion.6/1kV 1 2 3 4 5 6 Applications BostrigTM Type P Marine and Offshore Cable is primarily designed for power. Features • Superior resistance to oil. meeting IEEE 1580 (2001). control.6/1kV Individual and overall shielded multipair / armored and sheathed TYPE P SIGNAL CABLE 600V or 0.2 No. Jacket 5 Armor 6. Sheath Soft annealed stranded tinned copper per ASTM B 33. Flame-retardant Arctic Neoprene. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. An aluminum/polyester tape with drain wire. Listed by ETL per IEEE 1580 (2001). 16 & 14 AWG Approvals ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). Construction 1. 12 • 39 25 • 82 1470 • 2188 TP(I/S-0S)16PNBS-24 026441 24 .6 68 • 223 0.5 .12 • 39 25 • 82 350 • 521 TP(I/S-0S)16PNBS-3 026431 3 .060 • 1.76 .030 • 0.0 1.8 1.7 68 • 223 0.125 • 3.080 • 2.8 1.4 68 • 223 0.535 • 13.030 • 0.0 .12 • 39 25 • 82 1030 • 1533 TP(I/S-0S)14PNBS-12 026451 12 .885 • 22.030 • 0.6 68 • 223 0.8 1.030 • 0.76 .76 .10 • 33 28 • 92 220 • 327 TP(I/S-0S)14PNBS-2 026443 2 .1 68 • 223 0.76 .030 • 0.0 1.030 • 0.575 • 14.080 • 2.6/1kV 16 AWG • 1.0 68 • 223 0.235 • 31.900 • 22.5 .76 .030 • 0.060 • 1.5 68 • 223 0.0 1.030 • 0.030 • 0.12 • 39 25 • 82 190 • 283 TP(I/S-0S)16PNBS-2 026430 2 .76 .030 • 0.6 68 • 223 0.12 • 39 25 • 82 635 • 945 TP(I/S-0S)16PNBS-8 026436 8 .12 • 39 25 • 82 2260 • 3363 Ω/kft .0 1.140 • 29.2 68 • 223 0.23 mm2 Type Designation Draka Number Number of Pairs Insulation Thickness in • mm Sheath Cable Diameter Thickness (nominal) in • mm in • mm Characteristic Impedance TP(0S)16PNBS-1 026429 1 .110 • 2.76 .030 • 0.0 1.080 • 2.0 .800 • 45.5 .080 • 2.2 1.12 • 39 25 • 82 1255 • 1868 TP(I/S-0S)16PNBS-20 026440 20 .0 68 • 223 0.215 • 30.12 • 39 25 • 82 575 • 856 TP(I/S-0S)14PNBS-5 026446 5 .2 68 • 223 0.76 .12 • 39 25 • 82 900 • 1339 TP(I/S-0S)14PNBS-10 026450 10 .030 • 0.030 • 0.12 • 39 25 • 82 810 • 1205 TP(I/S-0S)14PNBS-8 026449 8 .76 .12 • 39 25 • 82 545 • 811 TP(I/S-0S)16PNBS-6 026434 6 .76 .DrakaMOG.580 • 40.080 • 2.9 68 • 223 0.12 • 39 25 • 82 610 • 908 TP(I/S-0S)16PNBS-7 026435 7 .76 .com .6 68 • 223 0.060 • 1.080 • 2.0 68 • 223 0. 36 www.030 • 0.030 • 0.4 68 • 223 0.965 • 24.030 • 0.76 .76 .8 1.12 • 39 25 • 82 875 • 1302 TP(I/S-0S)16PNBS-12 026438 12 .12 • 39 25 • 82 490 • 729 TP(I/S-0S)16PNBS-5 026433 5 .030 • 0.9 68 • 223 0.5 68 • 223 0.920 • 23.3 68 • 223 0.0 1.080 • 2.030 • 0.Bostrig Type P 0807 Page 22 of 62 BOSTRIG™ TYPE P SIGNAL CABLE individual and overall shielded multipair / armored and sheathed 16 & 14 AWG / 600V or 0.76 .76 .94 mm2 Type Designation Draka Number Number of Pairs Insulation Thickness in • mm Sheath Cable Diameter Thickness (nominal) in • mm in • mm Characteristic Impedance TP(0S)14PNBS-1 026693 1 .465 • 37. This information is not meant to replace the information in the appropriate and applicable standard or code.025 • 26.5 .12 • 39 25 • 82 1860 • 2786 Ω/kft .5 68 • 223 0.445 • 36.080 • 2.76 .76 .0 1.6 68 • 223 0.8 68 • 223 0.76 .76 .76 .Ω/km Cable Weight Inductance Capacitance (approximate) mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km 14 AWG • 1.030 • 0.030 • 0. please consult the factory or your representative to confirm all engineering information.805 • 20.080 • 2.285 • 32.76 .970 • 24.080 • 2.030 • 0.12 • 39 25 • 82 385 • 573 TP(I/S-0S)14PNBS-3 026444 3 .080 • 2.980 • 50.125 • 3.12 • 39 25 • 82 490 • 729 TP(I/S-0S)14PNBS-4 026445 4 .110 • 2.76 .080 • 2.8 68 • 223 0.030 • 0.12 • 39 25 • 82 650 • 967 TP(I/S-0S)14PNBS-6 026447 6 .835 • 46.060 • 1.12 • 39 25 • 82 965 • 1436 TP(I/S-0S)16PNBS-16 026439 16 .030 • 0.0 .820 • 20.0 1.0 1.7 68 • 223 0.6 60 • 197 0.76 .080 • 2.080 • 2.12 • 39 25 • 82 1960 • 2917 TP(I/S-0S)14PNBS-24 026454 24 .12 • 39 25 • 82 1525 • 2269 TP(I/S-0S)14PNBS-20 026453 20 .125 • 3.0 68 • 223 0.12 • 39 25 • 82 780 • 1161 TP(I/S-0S)14PNBS-7 026448 7 .0 .290 • 32.140 • 29.12 • 39 25 • 82 1250 • 1860 TP(I/S-0S)14PNBS-16 026452 16 .12 • 39 25 • 82 425 • 632 TP(I/S-0S)16PNBS-4 026432 4 .030 • 0.030 • 0.76 .2 1.585 • 40.110 • 2.Ω/km Cable Weight Inductance Capacitance (approximate) mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km This information is provided for reference only.0 1.030 • 26.110 • 2.080 • 2.0 .025 • 26.76 .2 1.2 68 • 223 0.205 • 30.76 .12 • 39 25 • 82 800 • 1191 TP(I/S-0S)16PNBS-10 026437 10 .030 • 0. Category A. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. Larger diameter cables carry a new flexible design.Bostrig Type P 0807 Page 43 of 62 BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0. Features • Superior resistance to oil. marine vessels and oil and gas drilling rigs. 100% coverage.2 No. Insulation 3. Jacket Soft annealed stranded tinned copper per ASTM B 33. UL1309/CSA245 and the performance requirements of IEC 60092-3. 0. IEEE 1580 (2001). Det Norske Veritas Type Approval Certificates E8792. E8794. Listed by ETL per IEEE 1580 (2001). The single pair construction has only the overall shield. sunlight. Flame-retardant Arctic Neoprene. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Shield 4. Bostrig cables have excellent resistance to oil. An aluminum/polyester tape with drain wire. 95/00161 (E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured tc BIW Specifying Standard J105 Construction 1. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). A polyester tape separator is used over the conductor. moisture. Bostrig Type P chemically cross-inked polyolefin (XLPO). Lloyds Registry of Shipping Approval Certificates No. is applied over each twisted pair and the cabled core.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. moisture. sunlight and ester-based mud (Type P-MR). Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225.6/1kV 1 2 3 20 & 18 AWG 4 Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. TM This product is readily available in an armored and sheathed version. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. Conductors 2. signal and instrumentation applications for offshore.6/1kV Individual and overall shielded multipair / unarmored TYPE P CONTROL CABLE 600V or 0. 37 www.com . control. abrasion. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. land rigs. E8795 and E8796. mud. complying with Type N Neoprene as required in IEEE-1580 (2001). meeting IEEE 1580 (2001).DrakaMOG. E8793. Thickness as shown in tables on opposite page. abrasion.3). 2 225 • 335 TP(I/S-0S)18PN-5 026355 5 .060 • 1.4 285 • 424 TP(I/S-0S)18PN-7 026357 7 .5 .060 • 1.1 720 • 1071 Number of Pairs Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km Type Designation Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km 18 AWG • 0.030 • 0.800 • 20.060 • 1.0 .030 • 0.5 .76 .76 .080 • 2.110 • 2.0 1.080 • 2.160 • 29.030 • 0.2 510 • 759 TP(I/S-0S)20PN-20 026349 20 .76 .6/1kV 20 AWG • 0.045 • 26.76 .265 • 32.060 • 1.5 400 • 595 TP(I/S-0S)20PN-16 026348 16 .450 • 36.9 360 • 536 TP(I/S-0S)20PN-12 026347 12 .0 .5 .0 245 • 365 TP(I/S-0S)18PN-6 026356 6 .030 • 0.030 • 0.060 • 1.5 .030 • 0.DrakaMOG.060 • 1.1 180 • 268 TP(I/S-0S)18PN-4 026354 4 .5 .0 1.76 .5 .030 • 0.5 .765 • 19.76 .080 • 2.060 • 1.130 • 28.76 .060 • 1.5 190 • 283 TP(I/S-0S)20PN-6 026343 6 .030 • 0.080 • 2.5 720 • 1071 TP(I/S-0S)18PN-20 026362 20 .350 • 8.060 • 1.5 825 • 1228 TP(I/S-0S)18PN-24 026363 24 .060 • 1.030 • 0.030 • 0.900 • 22.030 • 0.550 • 13.76 .8 230 • 342 TP(I/S-0S)20PN-8 026345 8 .8 215 • 320 TP(I/S-0S)20PN-7 026344 7 .030 • 0.76 .675 • 17.080 • 2.8 1.5 . please consult the factory or your representative to confirm all engineering information.0 1.080 • 2.710 • 18.5 .76 .925 • 23.080 • 2.5 565 • 841 TP(I/S-0S)18PN-16 026361 16 .3 340 • 506 TP(I/S-0S)18PN-8 026358 8 .030 • 0.76 .76 .76 .030 • 0.96 mm2 Type Designation Draka Number TP(0S)18PN-1 1 .0 515 • 766 TP(I/S-0S)18PN-12 026360 12 .3 265 • 394 TP(I/S-0S)20PN-10 026346 10 .030 • 0.5 .635 • 16.76 .9 65 • 97 TP(I/S-0S)18PN-2 026352 2 .76 .700 • 17. This information is not meant to replace the information in the appropriate and applicable standard or code.76 .7 120 • 179 TP(I/S-0S)20PN-3 026340 3 .030 • 0.080 • 2.025 • 26.Bostrig Type P 0807 Page 44 of 62 BOSTRIG™ TYPE P CONTROL CABLE individual and overall shielded multipair / unarmored 20 & 18 AWG / 600V or 0.605 • 15.030 • 0.330 • 8.030 • 26.030 • 0.9 135 • 201 TP(I/S-0S)20PN-4 026341 4 .76 .060 • 1.76 .4 440 • 655 TP(I/S-0S)18PN-10 026359 10 .030 • 0.76 .960 • 24.5 .650 • 16.080 • 2.030 • 0. 38 www.2 165 • 246 TP(I/S-0S)20PN-5 026342 5 .4 160 • 238 TP(I/S-0S)18PN-3 026353 3 .5 .240 • 31.76 .030 • 0.8 1060 • 1577 This information is provided for reference only.5 .61 mm2 Draka Number Number of Pairs Insulation Thickness in • mm Sheath Thickness in • mm TP(0S)20PN-1 026338 1 .com .0 1.0 .700 • 17.030 • 0.76 .080 • 2.76 .4 55 • 92 TP(I/S-0S)20PN-2 026339 2 .76 .060 • 1.060 • 1.030 • 0.0 1.760 • 19.030 • 0.030 • 0.060 • 1.030 • 0.600 • 15.5 .7 600 • 893 TP(I/S-0S)20PN-24 026350 24 .5 .060 • 1.76 .76 .0 1.0 1.540 • 13.76 . signal and instrumentation applications for offshore. complying with Type N Neoprene as required in IEEE 1580 (2001). 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J106 This product is readily available in an unarmored version. Insulation 3. They are suitable for use in Class I. Features • Superior resistance to oil.Bostrig Type P 0807 Page 19 of 62 BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). mud. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. land rigs. Bostrig Type P chemically cross-inked polyolefin (XLPO). is applied over each twisted pair and the cabled core. 0.6/1kV 1 2 3 4 5 6 20 & 18 AWG Applications Approvals Bostrig Type P Marine and Offshore Cable is primarily designed for power. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. Thickness as shown on data sheet for unarmored version. Lloyds Registry of Shipping Approval Certificates No. E8794.2 No. Armor 6. UL 1309/CSA245 and the performance requirements of IEC 60092-3. Det Norske Veritas Type Approval Certificates E8792.3). complying with Type N Neoprene as required in IEEE-1580 (2001). Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225.com . abrasion. 100% coverage. Sheath Soft annealed stranded tinned copper per ASTM B 33. Conductors 2. moisture.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Braided bronze in accordance with IEEE 1580 (2001). meeting IEEE 1580 (2001). crush and impact • Meets IEEE standards for 600V / IEC standards for 0. abrasion. E8795 and E8796. Construction 1.DrakaMOG. Listed by ETL per IEEE 1580 (2001).6/1kV Individual and overall shielded multipair / armored and sheathed TYPE P SIGNAL CABLE 600V or 0. sunlight and ester-based mud (Type P-MR). An aluminum/polyester tape with drain wire. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. IEEE 1580 (2001). They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. 39 www. A polyester tape separator is used over the conductor. moisture. Bostrig cables have excellent resistance to oil. Thickness as shown in tables on opposite page. sunlight. marine vessels and oil and gas drilling rigs. Category A. E8793. The single pair construction has only the overall shield. Flame-retardant Arctic Neoprene. control. Jacket 5. TM The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Flame-retardant Arctic Neoprene applied over the armor. Shield 4. Larger diameter cables carry a new flexible design. 150 • 29.14 • 46 21 • 69 500 • 744 TP(I/S-0S)20PNBS-8 026410 8 .0 1.76 .730 • 18.DrakaMOG.110 • 2.080 • 2.8 1.520 • 38.76 .030 • 0.030 • 0.545 • 39.61 mm2 Type Designation Draka Number Number of Pairs Insulation Thickness in • mm Sheath Cable Diameter Thickness (nominal) in • mm in • mm Characteristic Impedance TP(0S)20PNBS-1 026403 1 .990 • 25.6 73 • 239 0.14 • 46 21 • 69 170 • 253 TP(I/S-0S)20PNBS-2 026404 2 .080 • 2.060 • 1.350 • 34.76 .13 • 43 23 • 75 1350 • 2009 TP(I/S-0S)18PNBS-24 026428 24 .8 82 • 269 0.8 1.080 • 2.030 • 0.2 73 • 239 0.76 .l4 • 46 21 • 69 885 • 1317 TP(I/S-0S)20PNBS-20 026414 20 .76 .3 82 • 269 0.080 • 2.265 • 32.13 • 43 23 • 75 910 • 1354 TP(I/S-0S)18PNBS-16 026426 16 .5 .76 .030 • 0.925 • 23.080 • 2.110 • 2.030 • 0.76 .060 • 1.76 .080 • 2.030 • 0.720 • 18.76 .080 • 2.030 • 0.6/1kV 20 AWG • 0.0 73 • 239 0.8 1.030 • 0.535 • 13.Bostrig Type P 0807 Page 20 of 62 BOSTRIG™ TYPE P SIGNAL CABLE individual and overall shielded multipair / armored and sheathed 20 & 18 AWG / 600V or 0.0 1.Ω/km This information is provided for reference only.14 • 46 21 • 69 1260 • 1875 Insulation Thickness in • mm Sheath Cable Diameter Thickness (nominal) in • mm in • mm Ω/kft .440 • 36.13 • 43 23 • 75 845 • 1257 TP(I/S-0S)18PNBS-12 026425 12 .76 .76 .080 • 2.030 • 0.14 • 46 21 • 69 690 • 1027 TP(I/S-0S)20PNBS-12 026412 12 .13 • 43 23 • 75 505 • 752 TP(I/S-0S)18PNBS-6 026421 6 .7 73 • 239 0.8 1.13 • 43 23 • 75 350 • 521 TP(I/S-0S)18PNBS-3 026418 3 .030 • 0.180 • 30.030 • 0.5 82 • 269 0.030 • 0.0 .110 • 2.13 • 43 23 • 75 395 • 588 TP(I/S-0S)18PNBS-4 026419 4 .5 .5 . This information is not meant to replace the information in the appropriate and applicable standard or code.930 • 23.0 1.13 • 43 23 • 75 725 • 1079 TP(I/S-0S)18PNBS-10 026424 10 .785 • 19.96 mm2 Characteristic Impedance Cable Weight Inductance Capacitance (approximate) mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km Type Designation Draka Number Number of Pairs TP(0S)18PNBS-1 026664 1 .030 • 0.76 .76 .8 82 • 269 0.080 • 2.0 .5 .76 .13 • 43 23 • 75 1680 • 2500 Ω/kft .76 .76 .5 82 • 269 0.060 • 1.9 82 • 269 0.Ω/km Cable Weight Inductance Capacitance (approximate) mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km 18 AWG • 0.120 • 28.3 82 • 269 0.13 • 43 23 • 75 570 • 848 TP(I/S-0S)18PNBS-7 026422 7 .76 .925 • 23.9 73 • 239 0.890 • 22.2 82 • 269 0.030 • 0.14 • 46 21 • 69 730 • 1086 TP(I/S-0S)20PNBS-16 026413 16 .080 • 2.250 • 31.76 .14 • 46 21 • 69 440 • 655 TP(I/S-0S)20PNBS-6 026408 6 .14 • 46 21 • 69 485 • 722 TP(I/S-0S)20PNBS-7 026409 7 .0 .780 • 19.6 73 • 239 0.760 • 44.060 • 1.0 82 • 269 0. please consult the factory or your representative to confirm all engineering information.5 73 • 239 0.030 • 0.6 73 • 239 0.980 • 24.13 • 43 23 • 75 465 • 692 TP(I/S-0S)18PNBS-5 026420 5 .030 • 0.76 .110 • 2.080 • 2.com .080 • 2.245 • 31.14 • 46 21 • 69 550 • 818 TP(I/S-0S)20PNBS-10 026411 10 .030 • 0.060 • 1.6 82 • 269 0.510 • 13.030 • 0.13 • 43 23 • 75 1135 • 1689 TP(I/S-0S)18PNBS-20 026427 20 .060 • 1.13 • 43 23 • 75 605 • 900 TP(I/S-0S)18PNBS-8 026423 8 .13 • 43 23 • 75 185 • 275 TP(I/S-0S)18PNBS-2 026417 2 .030 • 0.5 73 • 239 0.76 .5 .0 1.14 • 46 21 • 69 320 • 476 TP(I/S-0S)20PNBS-4 026406 4 .6 73 • 239 0.76 .895 • 22.060 • 1.080 • 2.030 • 0.5 82 • 269 0.5 .0 1.080 • 2.0 .020 • 25.2 82 • 269 0.6 73 • 239 0.0 1.0 1.030 • 0.76 .030 • 0.030 • 0.845 • 21.76 .76 .76 . 40 www.030 • 0.030 • 0.080 • 2.7 73 • 239 0.5 82 • 269 0.14 • 46 21 • 69 360 • 536 TP(I/S-0S)20PNBS-5 026407 5 .14 • 46 21 • 69 295 • 439 TP(I/S-0S)20PNBS-3 026405 3 .0 .030 • 0.76 .0 .5 .14 • 46 21 • 69 1060 • 1577 TP(I/S-0S)20PNBS-24 026415 24 .0 1.0 .1 73 • 239 0. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998). American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. E8793. Thickness as shown in tables on opposite page. abrasion. moisture. Bostrig cables have excellent resistance to oil. sunlight and ester-based mud (Type P-MR). Shield 4. A polyester tape separator is used over the conductor. Flame-retardant Arctic Neoprene.2 No. Lloyds Registry of Shipping Approval Certificates No. Det Norske Veritas Type Approval Certificates E8792. is applied over each twisted pair and the cabled core. crush and impact • Meets IEEE standards for 600V / IEC standards for 0. Listed by ETL per IEEE 1580 (2001). They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. mud. UL1309/CSA245 and the performance requirements of IEC 60092-3. 41 www. marine vessels and oil and gas drilling rigs. land rigs. control. IEEE 1580 (2001). The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. complying with Type N Neoprene as required in IEEE-1580 (2001). meeting IEEE 1580 (2001). 95/00161 (E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured tc BIW Specifying Standard J106 Construction 1.DrakaMOG.com . signal and instrumentation applications for offshore. Jacket Soft annealed stranded tinned copper per ASTM B 33. Insulation 3.6/1kV 1 2 3 18 & 16 AWG 4 Applications Approvals BostrigTM Type P Marine and Offshore Cable is primarily designed for power. Conductors 2. Category A. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. Features • Superior resistance to oil. moisture.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. 100% coverage.3). abrasion. This product is readily available in an armored and sheathed version. E8795 and E8796. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. 0. sunlight. Bostrig Type P chemically cross-inked polyolefin (XLPO).Bostrig Type P 0807 Page 47 of 62 BOSTRIG™ TYPE P SIGNAL CABLE Individual and overall shielded multi-triad / unarmored TYPE P SIGNAL CABLE 600V or 0. An aluminum/polyester tape with drain wire. E8794. Larger diameter cables carry a new flexible design. The single pair construction has only the overall shield. 030 • 0.705 • 17.030 • 0.76 .5 .030 • 0.070 • 27.76 .9 265 • 394 TT(I/S-0S)18PN-5 026459 5 . please consult the factory or your representative to confirm all engineering information.060 • 1.630 • 16.915 • 23.76 .740 • 18.060 • 1.360 • 9.76 .7 315 • 469 TT(I/S-0S)18PN-6 026460 6 .080 • 2.3 715 • 1064 Draka Number Number of Triads Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km TT(0S)16PN-1 026625 1 .605 • 15.76 .030 • 0.060 • 1.9 805 • 1198 TT(I/S-0S)16PN-16 026472 16 .23 mm2 Type Designation This information is provided for reference only.76 .6/1kV 18 AWG • 0.060 • 1.0 .1 75 • 111 TT(I/S-0S)18PN-2 026456 2 .5 . This information is not meant to replace the information in the appropriate and applicable standard or code.76 .5 495 • 737 TT(I/S-0S)18PN-12 026462 12 .5 .030 • 0.030 • 0.155 • 29.060 • 1.030 • 0.030 • 0.76 .0 180 • 268 TT(I/S-0S)16PN-3 026466 3 .080 • 2.030 • 0.815 • 20.5 .76 .060 • 1.5 .5 1050 • 1563 16 AWG • 1.775 • 19.5 .76 .8 295 • 439 TT(I/S-0S)16PN-5 026468 5 .4 390 • 580 TT(I/S-0S)18PN-8 026461 8 .5 .4 85 • 126 TT(I/S-0S)16PN-2 026465 2 .060 • 1.955 • 24.0 .5 .2 625 • 930 TT(I/S-0S)16PN-12 026471 12 .060 • 1.080 • 2.030 • 0.030 • 0.060 • 1. 42 www.030 • 0.640 • 16.Bostrig Type P 0807 Page 48 of 62 BOSTRIG™ TYPE P SIGNAL CABLE individual and overall shielded multitriad / unarmored 18 & 16 AWG / 0.7 355 • 528 TT(I/S-0S)16PN-6 026469 6 .0 1.76 .080 • 2.030 • 0.76 .670 • 17.76 .com .0 1.96 mm2 Type Designation Draka Number TT(0S)18PN-1 Number of Triads Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km 1 .0 1.030 • 0.76 .4 165 • 246 TT(I/S-0S)18PN-3 026457 3 .5 .030 • 0.030 • 0.080 • 2.880 • 22.76 .0 1.1 446 • 662 TT(I/S-0S)16PN-8 026470 8 .030 • 0.060 • 1.080 • 2.370 • 9.215 • 30.5 .0 235 • 350 TT(I/S-0S)16PN-4 026467 4 .76 .080 • 2.76 .3 210 • 313 TT(I/S-0S)18PN-4 026458 4 .360 • 34.0 .DrakaMOG. Insulation 3. abrasion.6/1kV Individual and overall shielded multi-triad / armored and sheathed TYPE P SIGNAL CABLE 600V or 0. The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. meeting IEEE 1580 (2001). Thickness as shown in tables on opposite page. IEEE 1580 (2001). moisture. Flame-retardant Arctic Neoprene applied over the armor. control. sunlight and ester-based mud (Type P-MR). 0. Shield 4. The single pair construction has only the overall shield. A polyester tape separator is used over the conductor.6/1kV Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. Braided bronze in accordance with IEEE 1580 (2001). Features • Superior resistance to oil. Bostrig cables have excellent resistance to oil. crush and impact • Meets IEEE standards for 600V / IEC standards for 0.com .DrakaMOG. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. moisture. land rigs. UL 1309/CSA245 and the performance requirements of IEC 60092-3. Thickness as shown on data sheet for unarmored version. complying with Type N Neoprene as required in IEEE 1580 (2001). sunlight. Category A.2 No. Det Norske Veritas Type Approval Certificates E8792. Listed by ETL per IEEE 1580 (2001).Bostrig Type P 0807 Page 23 of 62 BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0. 43 www. American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA. Construction 1. 100% coverage. Flame-retardant Arctic Neoprene. E8794. is applied over each twisted pair and the cabled core. They are suitable for use in Class I. signal and instrumentation applications for offshore. Jacket 5 Armor 6. Sheath Soft annealed stranded tinned copper per ASTM B 33. mud. Lloyds Registry of Shipping Approval Certificates No. Larger diameter cables carry a new flexible design.3). Conductors 2. ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45 (1998).6/1kV 1 2 3 4 5 6 18 & 16 AWG Applications Approvals BostrigTM Type P Marine and Offshore Cable is primarily designed for power. E8795 and E8796. UL 1309/CSA 245 and IEEE 45 (1998) for 600V. Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225. complying with Type N Neoprene as required in IEEE-1580 (2001). Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225. Bostrig Type P chemically cross-inked polyolefin (XLPO). E8793. An aluminum/polyester tape with drain wire. abrasion. marine vessels and oil and gas drilling rigs. 95/00161(E3) and 95-00162(E3) Transport Canada Approved AMS400-20-2 Manufactured to BIW Specifying Standard J106 This product is readily available in an unarmored version. 995 • 25.76 .8 1.0 210 • 313 TT(I/S-0S)16PNBS-2 026483 2 .0 1.76 .6 1180 • 1756 TT(I/S-0S)18PNBS-16 026481 16 .960 • 24.5 .100 • 28.8 950 • 1414 TT(I/S-0S)16PNBS-12 026489 12 .030 • 0.030 • 0.8 1.0 1.7 770 • 1146 TT(I/S-0S)16PNBS-8 026488 8 .440 • 36.290 • 32. please consult the factory or your representative to confirm all engineering information.76 .76 .030 • 0.0 .080 • 2.76 .76 .0 1.5 .7 200 • 298 TT(I/S-0S)18PNBS-2 026474 2 .080 • 2.930 • 23.8 1.080 • 2.030 • 0.110 • 2.9 1450 • 2158 16 AWG • 1.110 • 2.110 • 2.080 • 2.76 .76 .DrakaMOG.060 • 1.030 • 0.030 • 0.030 • 0.030 • 0. This information is not meant to replace the information in the appropriate and applicable standard or code.030 • 0.3 645 • 960 TT(I/S-0S)16PNBS-6 026487 6 .080 • 2.0 .890 • 22.76 .76 .810 • 20.5 .6/1kV 18 AWG • 0.640 • 41.540 • 13.030 • 0.030 • 0.175 • 29.080 • 2.035 • 26.23 mm2 Type Designation Draka Number Number of Triads Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km TT(0S)16PNBS-1 026716 1 . 44 www.76 .6 525 • 781 TT(I/S-0S)18PNBS-5 026477 5 .080 • 2.com .130 • 28.76 .6 430 • 640 TT(I/S-0S)18PNBS-4 026476 4 .96 mm2 Type Designation Draka Number Number of Triads Insulation Thickness in • mm Sheath Thickness in • mm Cable Diameter (nominal) in • mm Cable Weight (approximate) Lbs/mft • Kg/km TT(0S)18PNBS-1 026473 1 .9 360 • 536 TT(I/S-0S)18PNBS-3 026475 3 .76 .7 1565 • 2329 This information is provided for reference only.0 1280 • 1905 TT(I/S-0S)16PNBS-16 026490 16 .9 825 • 1228 TT(I/S-0S)18PNBS-12 026480 12 .76 .0 1.080 • 2.030 • 0.030 • 0.060 • 1.8 1.850 • 21.785 • 19.030 • 0.76 .060 • 1.6 380 • 566 TT(I/S-0S)16PNBS-3 026484 3 .0 .030 • 0.495 • 38.030 • 0.76 .080 • 2.5 .030 • 0.110 • 2.5 .060 • 1.550 • 14.6 485 • 722 TT(I/S-0S)16PNBS-4 026485 4 .76 .0 .Bostrig Type P 0807 Page 24 of 62 BOSTRIG™ TYPE P SIGNAL CABLE individual and overall shielded multi-triad / armored and sheathed 18 & 16 AWG / 0.0 1.3 590 • 878 TT(I/S-0S)18PNBS-6 026478 6 .76 .570 • 39.0 715 • 1064 TT(I/S-0S)18PNBS-8 026479 8 .060 • 1.030 • 0.4 570 • 848 TT(I/S-0S)16PNBS-5 026486 5 . complying with Type N Neoprene as required in IEEE-1580 (2001). A system ground is REQUIRED for supplying power from the switchboard to the inverter and then to the motor. Braided bronze in accordance with IEEE 1580 (2001). The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. abrasion.3). Category A. Larger diameter cables carry a new flexible design. moisture and sunlight and ester-based mud (Type P-MR). Bostrig Type P cables comply to UL 1277 Type TC exposed runs requirements and with the crush and impact requirements of UL 2225. and toxicity • Superior resistance to oil. Bostrig cables have excellent resistance to oil. Division I and Zone I applications (armored & sheathed) and meet the crush and impact resistance requirements (C&IR) of UL 2225 and complies with UL 1277 Type TC exposed runs requirements.com . a cable with a lesser ground can be ordered. Sheath (Optional) Soft annealed tinned copper per ASTM B 33.DrakaMOG. This cable is ETL listed per IEEE 45 (1998). IEEE 1580 (2001) and UL 1309/CSA 245. 0. Braided tinner cooper for 95% coverage. mud. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22. Lloyds and Transport Canada. abrasion. Conductors 2. Ground Conductors 4. smoke. This product can be manufactured in an unarmored or armored and sheathed version. crush and impact • Gigabit Ethernet 802. Flame-retardant Arctic Neoprene applied over the armor. Features • Low smoke/zero halogen construction meets appropriate IEEE and IEC standards for fire.3Z compliant Ratings Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3. meeting IEEE 1580 (2001). 45 www. moisture. All Bostrig Type P-VFD Cables listed in this specification sheet are built using system grounds equal to the aggregte cross-section of a phase conductor and can be in contact with or isolated from the overall shield.Bostrig Type P 0807 Page 57 of 62 BOSTRIG™ TYPE P-VFD POWER CABLE 2000V Shielded three conductor / unarmored or armored and sheathed TYPE P VFD CABLE 2000V 1 2 3 4 5 6 7 1/0 AWG to 777 MCM Applications BostrigTM Type P shielded three conductor VFD Marine and Offshore Cable is designed specifically for use with variable frequency AC motor drives. complying with Type N Neoprene as required in IEEE 1580 (2001). A polyester tape separator is used over the conductor. Flame-retardant Arctic Neoprene. Insulation 3. sunlight. Construction 1. ABS. Armor (Optional) 7. Shield 5. Listed by ETL per IEEE 1580 (2001). Type approved by DNV.2 No. Insulation is printed with phase markings as required. Thickness as shown in tables on opposite page. Jacket 6. If the VFD cable is only being used between the motor and the inverter. They are suitable for use in Class I. UL 1309/CSA 245 and IEEE 45 (1998) for 2000V. Bostrig Type P chemically cross-inked polyolefin (XLPO). 09 • 0.3 0.6 2.4 0.5 4 AWG • 21.5 .6 3.Ω/km Capacitance pF/ft • pF/m armored and sheathed Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Type Designation Draka Number Conductor Size AWG/MCM • mm2 TP(OBS)NBS-1/0 036038 4/0 • 112.6 1 AWG • 56.5 n/a 1.11 • 2.09 • 0.3 .14 • 3.09 • 0.4 0.3 212 • 695 175 • 188 • 201 3420 • 5089 TP(OBS)NBS-4/0 036040 4/0 • 112.3 259 • 850 241 • 252 • 270 5510 • 8199 TP(OBS)NBS-262 036041 262 • 133.8 2.09 • 0.08 • 0.37 • 85.14 • 3.2 310 AWG • 92.3 247 • 810 267 • 294 • 315 5050 • 7514 TP(OBS)N-313 036032 313 • 158.Ω/km Capacitance pF/ft • pF/m Calculated Ampacity† Cable Weight (measured @ ºC) (approximate) 95 • 100 • 110 Lbs/mft • Kg/km Type Designation Draka Number Conductor Size AWG/MCM • mm2 TP(OBS)N-1/0 036028 1/0 • 56.52 • 89.09 • 0.1 n/a 3.09 • 0.09 • 0.3 5 AWG •18.6 .8 2.4 0.1 .3 n/a 2.1 .0 0.2 270 • 886 298 • 321 • 344 7010 • 10431 TP(OBS)NBS-373 036043 373 • 189.2 292 • 958 333 • 361 • 387 8360 • 12440 TP(OBS)NBS-444 036044 444 • 225. PHASE CONDUCTOR (3) SYSTEM GROUND (3) FILLERS (AS REQUIRED) MYLAR TAPE BRAIDED SHIELD JACKET BRAIDED ARMOR SHEATH 46 www.3 212 • 695 175 • 186 • 201 2640 • 3928 TP(OBS)N-4/0 036030 4/0 • 112. 4/0 AWG thru 1000 MCM multiply by O.65 • 67.56 • 65.3 345 • 1132 528 • 582 • 602 13520 • 20118 Ground Size AWG/MCM • mm2 Sheath Thickness in • mm Cable Diameter (nominal) in • mm Inductance Ω/kft .0 0.Bostrig Type P 0807 Page 58 of 62 BOSTRIG™ TYPE P-VFD POWER CABLE shielded three conductor / unarmored or armored and sheathed 1/0 AWG to 777 MCM / 2000V unarmored Ground Size AWG/MCM • mm2 Sheath Thickness in • mm Cable Diameter (nominal) in • mm Inductance Ω/kft .72.0 n/a 3.8 1.1 310 AWG • 92.6 110 AWG • 18.8 1.09 • 0.63 • 41.08 • 0.2 318 • 1043 371 • 411 • 440 8660 • 12886 TP(OBS)N-535 036035 535 • 271.0 1 AWG • 56.09 • 53. 2 AWG thru 3/OAWG multiply by 0.3 310 AWG • 92.6 .08 • 0.6 n/a 3.9 0.3 .86 • 98.11 • 2.14 • 3.6 n/a 1.3 210 AWG • 61.3 291 • 954 417 • 443 • 475 11350 • 16889 TP(OBS)NBS-646 036046 646 • 327.92 • 48.4 0.2 210 AWG • 61.08 • 0.3 314 • 1030 469 • 516 • 553 13130 • 19537 TP(OBS)NBS-777 036047 777 • 394.6 .3 190 • 623 156 • 164 • 176 2280 • 3393 TP(OBS)N-2/0 036029 2/0 • 66. † Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 .14 • 3.3 259 • 850 241 • 252 • 270 4480 • 6666 TP(OBS)N-262 036031 262 • 133.5 410 AWG • 112.53 • 38.5 n/a 2.DrakaMOG.09 • 0.3 190 • 623 156 • 164 • 176 3020 • 4494 TP(OBS)NBS-2/0 036039 4/0 • 112.09 • 0.6 n/a 2.11 • 2.6 1 AWG • 56.2 310 AWG • 92.6 0.3 247 • 810 267 • 294 • 315 6130 • 9121 TP(OBS)NBS-313 036042 313 • 158.52 • 89.0 0.6 3. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.6 3.2 0.66.03 • 77.1 1 AWG • 56.18 • 80.09 • 0.11 • 2.2 292 • 958 333 • 361 • 387 6950 • 10342 TP(OBS)N-444 036034 444 • 225.6 0.7 110 AWG • 18.23 • 56.52 • 64.3 n/a 2.6 4 AWG • 21.3 291 • 954 417 • 443 • 475 9700 • 14437 TP(OBS)N-646 036036 646 • 327.09 • 0.21 • 81.8 0.11 O’C values based on IEEE-45 Table 25 corrected for conductor temperature.2 262 KCMIL • 133.8 0.08 • 0.5 410 AWG • 112. This information is not meant to replace the information in the appropriate and applicable standard or code.7 0.1OOºC values based on IEEE-45 Table 25 .09 • 0.64. please consult the factory or your representative to confirm all engineering information.8 262 KCMIL • 133.6 3.11 • 2.5 0.1 n/a 2.1 0.38 • 60.14 • 3.2 318 • 1043 371 • 411 • 440 10230 • 15222 TP(OBS)NBS-535 036045 535 • 271.0 .5 .0 0.3 345 • 1132 528 • 582 • 602 15420 • 22944 This information is provided for reference only.8 2.com .2 270 • 886 298 • 321 • 344 5860 • 8720 TP(OBS)N-373 036033 373 • 189.87 • 72.9 0.0 0.36 • 60.82 • 46.08 • 0.3 314 • 1030 469 • 516 • 553 11400 • 16963 TP(OBS)N-777 036037 777 • 393.6 5 AWG •18.90 • 73.09 • 0. A. TX 77032 U.DrakaMOG. tel: +1 281 209 1070 fax: +1 281 209 3857 www. Suite 300 Houston. ASIA-PACIFIC: 25 Tuas South Street 1 Singapore 638034 tel: +65 6897 7888 fax: +65 6897 7333 .com © 2009 Draka Offshore.S. please contact any of our worldwide locations: EUROPE: Unit 3 Peterseat Drive Peterseat Park Altens Industrial Estate Aberdeen AB12 3HT U. or expert guidance for new-build projects. tel: +44 1224 244800 fax: +44 1224 249839 AMERICAS: 1610 Greens Road.K. All rights reserved.For maintenance and repair needs.
Copyright © 2024 DOKUMEN.SITE Inc.