DNV 2012 Results Options Dialog in AutoPIPE - Pipe Stress and Vessel Design - Wiki - Pipe Stress and Vessel Design - Bentley Communities



Comments



Description

DNV 2012 Results Options dialog inAutoPIPE Applies To Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Subarea: Original Author: Bentley Technical Support Group Details about the DNV 2012 Results Options dialog in AutoPIPE In AutoPIPE 09.06.xx.xx, select Tools> Model Options> DNV 2012 Results Options> to display the following dialog screen: Code Category Options Tab: for each of the Categories of calculations performed determine if that category will use Nominal thickness. Design Factor: . Also select the appropriate Safety Class. this setting will automatically adjust the Gamma value. or enter a user defined gamma value. This gamma setting is used in the calculation of of the code allowable. If the analysis was to consider every variation of Gr+Tn+Pn+Wn+Un there could literally be 100's of combinations. Category components section: These would be combinations that would be created based on the category settings of this section.These design factors are used in various calculations: Condition load effect factor is used in the load control axial load and design moment calculation. . The usage factor is used in the ASD check allowable. Code Combinations Tab Load effect Factors are used to multiply the indicated load case in the respective combination created by the "Category Components" settings below. Material Resistance factor is used in the allowable calculation for load categories. The Material Strength factor is used in the allowable calculation of Fy and Fu. The following settings limits the number of combinations created: USL Category: . ..Functional = Grt1p1 x (ULS Functional Factor) Environmental = W1 x (ULS Environmental Factor) Interference = U1 x (ULS Interference Factor) Combinations created: GrT1P1+W1+U1... GrT2P2+W1+U1....GRTnPn+W1+U1 Review the code calculations created under Tools> Combinations> Code Comb tab. . GrT2P2+W1+U1+S1.....ALS Category: Functional = Grt1p1 x (ALS Functional Factor) Environmental = W1 x (ALS Environmental Factor) Interference = U1 x (ALS Interference Factor) Accidental = S1 x (ALS Accidental Factor) Combinations created: GrT1P1+W1+U1+S1..GRTnPn+W1+U1+S Review the code calculations created under Tools> Combinations> Code Comb tab. . General tab: . B202 Select the pressure Case that will be updated per this calculation.4 B200" This dialog provide values used in the Incidental pressure calculation. per DNV -2012 sec 4. this is the internal pressure at any point in the pipeline system or pipe line section for the corresponding design pressure. incidental pressure or test pressure adjusted for the column of weight. see Sec. .The Specific gravity and External water surface can be changed under Load> Buoyancy Per code definition: "Local incidental .I relation to pipelines. Version. DNV Piping Code Enhancements for AutoPIPE .See Also Bentley AutoPIPE External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below..... "Include Bourdon rotational effect" model option in AutoPIPE Applies To Product(s): AutoPIPE.. THANK YOU!  DNV  AutoPIPE  Model Options  Piping Codes Related DNV Piping Code Calculation Issues in AutoPIPE Applies To Product(s): AutoPIPE. "Sustain Margin" (Y/N/E) option in AutoPIPE Applies To Product(s): AutoPIPE. Version. Version.. or Nuclear? Applies To Product(s): AutoPIPE.Applies To Product(s): AutoPIPE. Plus. Version.. What Piping codes are available in AutoPIPE Standard.. Version...    .
Copyright © 2024 DOKUMEN.SITE Inc.