Home
Login
Register
Search
Home
Dmx Architecture
Dmx Architecture
April 3, 2018 | Author: Teja Patti | Category:
Computer Data Storage
,
Computer Hardware
,
Electrical Engineering
,
Computer Architecture
,
Computer Engineering
DOWNLOAD
Share
Report this link
Comments
Description
GESTALT ITSearch this Search HOME TECH FIELD DAY JOBS ABOUT» CATEGORIES» @GESTALTIT You are here: Home / All / Tech / Storage / EMC Symmetrix DMX-4: Components EMC Symmetrix DMX-4: Components MARCH 16, 2009 BY DEVANG PANCHIGAR2 COMMENTS In my previous posts on EMC Symmetrix 3, 5, 8 Series and EMCSymmetrix DMX, DMX-2 Series we discussed some important components comprised in these systems. In this post we will discuss components of EMC Symmetrix DMX-4. EMC Symmetrix DMX-4 consist of 1 System Bay and (1 upto 8) Scalable Storage Bay’s. Each Storage Bay can hold up to 240 Disk Drives totaling 1920 drive in 8 Storage bays or 1024 TB System. Systems with special requirements can be configured to 2400 drives instead of standard 1920 drives. The primary bay is the System Bay which includes all directors, service processor, adapters, etc, while the Storage Bay contains all the disk drives, etc. System Bay (1 Bay) Channel directors: Front End Directors (FC, ESCON, FICON, GigE,iSCSI), these are the I/O Directors. Disk directors: Back End Directors (DA), these control the drives in the System. Global memory directors: Mirrored Memory available with DMX-4, Memory Director sizes range from 8GB, 16GB, 32GB or 64GB totaling 512GB (256GB mirrored). 1920 total in the system. Environmental monitoring is used to monitor all the VPD (Vital Product Data). 146GB and 200GB available. power on/off. 15 drives per enclosure Battery Backup Unit (BBU): 8 BBU modules per Storage bay. Power supplies: 3 Phase Delta or WYE configuration. drives. that is the interface between directors. between 3 to 5 mins of backup power in case of a catastrophic power failure. 8 BBUunits. Video. 240 per bay. 1TB and now EFD’s 73GB. Storage bay (1 Bay Minimum to 8 Bay’s Maximum) Disk drives: Combination of 73GB. they provide an interface to connect disk drives through the storage bays. 2 XCM located at the rear of the system bay. if the color of the LED is green. UPS: UPS for the Service Processor Silencers: Made of foam inside. diagnostics and configuration purposes. FICON. 15 drives per Enclosure. GigE.2K SATA are all compatible.Disk adapters: Back End Adapters. the speed is 4GB. 450GB. 500GB. Cooling fan modules: 3 Fans at the top of the bay to keep it cool. 15K. Zone A and Zone B based Power Supplies. cache. 7. Display and Mouse. Speed: 10K. Communications and Environmental Control (XCM) modules:Fabric and Environmental monitoring. 2 in total. maximum 8 of them in the system bay. Power distribution units (PDU): One PDU per zone. Channel adapters: Front End Adapters. each BBU support 4 Drive enclosures . If the color of the LED lights on the drive is Blue its 2GB speed. 400GB. 2 in total. ESCON. 300GB. call home. Power distribution panels (PDP): One PDP per zone. 146GB. Used for remote monitoring. Battery backup Unit (BBU): 2 Battery backup modules. similar type drives. This is the message fabric. etc. main power. iSCSI). Drive Enclosure Units: 16 per Storage Bay. Service processor components: Keyboard. different Silencers for System and Storage bay’s. they provide an interface for host connection (FC. each RAID Group and each drive enclosure should only have similar speed drives. . Fixes Specific For VM Backups MSSQL must really love Oracle (pun intended) VMworld Parties to follow FILED UNDER: STORAGETAGGED WITH: COMPONENTS. DMX4. Link Aggregation VMware View 4. Sponsors. we will discuss EMC Symmetrix DMX-4 and some of its design features. System Cooling Module: 2 per drive enclosure Link Control Cards: 2 per drive enclosure Power Distribution Unit (PDU): 1 PDU per zone. 2 in total In the next couple of post.1 U1 Released. Role Models and Heroes Moving On From Storage Tiering SSID Overhead – How Many Wi-Fi SSIDs Are Too Many? Why does SDN have more traction than IPv6? . 2 in total Power Distribution Panels (PDP): 1 PDP per zone. You might also want to read these other posts. Tom Hollingsworth andArjan Timmerman FACEBOOKGOOGLE+TWITTER RECENT POSTS Mentors. SYMMETRIX Gestalt .Power Supply.an organized field having properties that cannot be derived from the sum of component parts. a unified whole Editors: Stephen Foskett.. EMC.5: Rebalance vSphere 4. Storage Innovation – Diablo Technologies More Storage Moving On From Storage Tiering Storage Innovation – Diablo Technologies Sceptical markets snub Violin Memory: Can the flashy biz bounce back? Defining Software-Defined Storage Return to top of page Copyright © 2013 · Metro Theme on Genesis Framework · WordPress · Log in .
Report "Dmx Architecture"
×
Please fill this form, we will try to respond as soon as possible.
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
Copyright © 2024 DOKUMEN.SITE Inc.