-48VDC DELTA PSC3 SETTINGSI have come across many problems with new Delta PSU which has been swapped out and not done properly by the external contractors. Tonight just called out to site with similar looking issues which I like to share with you. 1. All the ones I managed to fix are due to the controller not been commissioned properly or not commissioned at all! You need to load the correct configuration files depending on the number of battery strings installed; I have the files and procedure which I will send out later. This will clear many of the alarms. 2. Set the correct number of rectifiers actually installed, this is simply a matter of log in via your PC and change settings under the Rectifier section and save config. 3. Many of you have come across this one whereby if you leave the controller plugged in and fully commissioned the DC power is cut-of completely too all the equipment connected. When you disconnect the controller the power kicks in (a clunk is heard from the solenoid which turns on the power). The reason for this is because the solenoid wires are crossed from factory! Yes hard to believe in fact true, come across 3 sites with this problem. Simply reverse these two black wires on the solenoid and problem solved (see pics) 4. External alarm cables incorrectly connected or not even connected at all, please see pic of how it should be connected and redefine on Node B so that, Port Port Port Port 9 10 11 12 is "Delta -48v Urgent Alarm" is "Delta -48v Non Urgent Alarm" is "Delta -48v Mains Failure" not used. For all ports define as Normally Open = False. Page 1 28/5/2010 Type exit to quit. o Check by clicking start.4. There are several user names but we should use: Username: configuration Password: psc3 You will then see the PSC 3 homepage as shown below.168. Page 2 28/5/2010 .DELTA PSC3 CONFIGURATION Enable the PSC 3 DHCP server. then ‘ipconfig’.168.100.100. type ‘cmd’. (Straight or crossed). Check the IP address is 192.100. Select menu ‘5. enter 192. In the address bar of the internet browser.1 DHCP’ on the PSC 3 panel and scroll to ‘server’ and press enter and accept ‘Yes’. Open an internet browser.100. The screen below will appear.168. The PC should be automatically given the IP address 192. run. The PC IP address will be shown.100 o If required the password is ‘up up down left left right’ using the arrows/exit/enter buttons Connect the computer to the PSC 3 with an Ethernet cable.101. If. Page 3 28/5/2010 . the version is 2. 2.42. It has been agreed that we upgrade all the sites we have to SW Version 2.30 you need to upgrade to 2. Browse the Upload/Download Directory to the configuration files location Browse to the screen shown below using the menu on the left hand side of the screen. The version can be seen in the screen shot above. You need to run ‘3CDaemon’ and use the TFTP server.30 and 2.42. as shown above.42.There are currently two SW Versions used in the Vodafone UK network. The following screens will appear.Enter the EXACT file name in the Filename box. Click Start. then OK in the message box. Page 4 28/5/2010 . You now need to load the correct configuration file for the site. Page 5 28/5/2010 . Configuration File Download These files are loaded to the PSC 3 from your PC as described below. Reconnect to the PSC 3 as described above and follow the instructions below. The TFTP server is built into this SW version but you still need to set the Symantec firewall to O&M as in Ericsson 3G commissioning.Close the browser. Check on the unit that the IP address is correct and that the DHCP is set to server. xml where: n = number of battery strings i. Page 6 28/5/2010 . The format is shown below: nB_2_3_DPS2000_48_8_VFGlobalUK.There are five configuration files available for SW Version 2.e. From the PSC 3 select the screen below using the menu on the left hand side of the screen. 0 to 4 depending on the setup at each site. In ‘File Type’ select ‘Setup’ in the dropdown box.42. Then click ‘Load File From PC’. Click Start and the Ok in the message box.xml file you require. Page 7 28/5/2010 . Then wait for the screen shown below indicating success.Click Browse and search for the . click Inspect and further information is given.Alarm Check Browse to alarms using the Menu and select status. An alarm may be active as above. Page 8 28/5/2010 . You need to browse to the rectifier menu as shown below. This shows that there are 4 rectifiers in situ but the SW is only expecting 3. Click Acknowledge and the SW recognises all 4 rectifiers. Page 9 28/5/2010 .This alarm is showing S Non Urgent RFA (rectifier Fail Alarm). Then click Update on the top menu.Click Save (Top left) where modified is displayed. All alarms should now be clear. Page 10 28/5/2010 . Page 11 28/5/2010 .Check by going back to the alarm status screen.