Datasheet SC1000CP-XT English V10 Ext

March 20, 2018 | Author: Pikesh Jain | Category: Power Inverter, Alternating Current, Manufactured Goods, Electrical Engineering, Electricity


Comments



Description

SC 1000CP-10SUNNY CENTRAL 1000CP XT Profitable Robust Flexible Versatile • 1 MW system power as standard • High power density for reduced transportation costs • Maximum yields with low system costs • Full nominal power in continuous operation at ambient temperatures up to 40 °C • Direct installation on-site, optimized for extreme climatic conditions of between -40°C and 62°C • OptiCool for active temperature management • Wide DC input voltage range for flexible use of various module configurations • Perfectly adjusted to temperature-dependent behavior of PV arrays • All grid management functions included, prepared for Q at Night • Optimal monitoring and control thanks to customized computing platform SUNNY CENTRAL 1000CP XT The most powerful CP with an output of 1 megawatt For increased power: With its expanded functions and a peak power of 1100 kVA, the new Sunny Central 1000CP XT is now even more powerful. With its proven technology and high power density, the SC 1000CP XT completes the worldwide most successful Sunny Central CP inverter family for PV. The central inverter for outdoor use is optimized for both full nominal power in continuous operation up to 40°C and cold temperatures as low as -40°C. The inverter includes all grid management functions and is prepared for Q at Night, including pure reactive power management. The customized computing platform allows optimal monitoring and control. D. Modbus ○/○ ● / ○ (via Sunny Portal) RAL 9016 / 9016 / 7004 / 7004 ●/○/○/○/○ Power reduction. 2 Rated input voltage Max. total harmonic distortion Power factor at rated power / displacement power factor adjustable Feed-in phases / connection phases Efficiency3 Max.9 overexcited to 0.635 A 1 8 1.. 4S2 ●/○ 15 .. output current / max.4% / 98. 62°C / -13 . R. 60 Hz / 47 . 1663 / 2000. 62°C / -40 . reactive power setpoint. CE-conformity..100 kVA / 1.D..000 m Fresh air consumption (inverter) Features DC connection / AC connection Display Communication / protocols DC current monitoring (Zone monitoring / String monitoring) SC-COM / Plant monitoring Color enclosure / door / base / roof Guarantee: 5 / 10 / 15 / 20 / 25 years Configurable grid management functions Certificates and approvals (more available on request) ● Standard features  ○ Optional features — Not available Type designation Sunny Central 1000CP XT 1. EN 61000-6-4.000 V 596 V 688 to 850 V / 625 to 850 V / 596 to 850 V 688 V 1.. efficiency / European efficiency / CEC efficiency Protective devices Input-side disconnection device Output-side disconnection device DC overvoltage protection Lightning protection (according to IEC 62305-1) Stand-alone grid detection active / passive Grid monitoring Ground fault monitoring Insulation monitoring Surge arrester for auxiliary power supply Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) General data Dimensions (W / H / D) Weight Operating temperature range Extended operating temperature range Max... 661 / 2007 SC 1000CP-10 .7% / 98.000 kVA / 900 kVA 405 V / 365 to 465 V 50 Hz. input current Number of independent MPP inputs Number of DC inputs Output (AC) nominal AC power (@ 40°C) / AC power (@ 50°C) Nominal AC voltage / nominal AC voltage range AC power frequency / range Rated power frequency / rated grid voltage Max. EMC-conformity. 144°F ○ (-40 .568 A / 0.9 underexcited 3/3 98. LVRT) EN 61000-6-2. self-consumption (operation)4 / self-consumption (night) External auxiliary supply voltage Cooling concept Degree of protection: electronics / connection area (according to IEC 60529) /  according to IEC 60721-3-4 Application in unprotected outdoor environments / indoor Maximum permissible value for relative humidity (non-condensing) Maximum operating altitude above MSL 2..g. DC power (@ cos φ =1) Max. 95 % ● 3000 m3/h Ring terminal lug / ring terminal lug HMI touch display Ethernet (optical fiber optional). 63 Hz 50 Hz / 405 V 1. R... dynamic grid support (e. Arrêté du 23/04/08. 144°F) 1900 W / < 100 W 230 / 400 V (3 / N / PE) OptiCool IP54 / IP43 / 4C2. input voltage VMPP_min at IMPP < IDCmax MPP voltage range (@ 25°C / @ 40°C / @ 50°C)1.122 kW 1.03 1 / 0. BDEWMSRL / FGW / TR8.562 / 2...SUNNY CENTRAL 1000CP XT Technical Data Input (DC) Max.5% Motor-driven load-break switch AC circuit breaker Type I surge arrester Lightning Protection Level III ● /— ● ○/○ ○ ● I / III 2.272 / 956 mm (101 / 89 / 38 inches) 1950 kg / 4300 lb -25 . see technical information at www.SMA.05 UAC. DC voltages and power classes can be configured (for more detailed information. nom and cos φ = 1 2) Further AC voltages.de) 3) Efficiency measured without internal power supply 4) Self-consumption at rated operation .PLANT DIAGRAM EFFICIENCY CURVE 1) At 1. www. at any time without notice.com SMA Solar Technology .com SC1000CP-DEN1448-V10   Printed on FSC-certified paper. see www. SMA assumes no liability for errors or omissions.SMA-Solar. even for reasons of country-specific deviations.SMA-Solar. For current information. All products and services described as well as technical data are subject to change.
Copyright © 2024 DOKUMEN.SITE Inc.