N OTHI N G LE SS. N OT H I N G E LSE .Nothing Less. Nothing Else. Think inverter ACs. Think Daikin. 100% copper coils in all models Contents About Daikin and Daikin India 01 Inverter technology 02 R-32, a next-generation refrigerant 06 Product line up 08 Unit options 28 Feature list 30 About DAIKIN Daikin® is a leading innovator and provider of advanced, high-quality air-conditioning solutions for residential, commercial and industrial applications. As World’s No. 1 Air-conditioning Company, Daikin is committed to delivering air-conditioning solutions that enhance the quality of life all around the world. A diverse multinational company, Daikin Industries Ltd., active in air-conditioning, chemicals and oil hydraulics, was established in 1924. With headquarters at Osaka, Japan, the Daikin family has more than 51,000 members, working across 60 production base units and 208 consolidated subsidiaries worldwide. As the world’s sole manufacturer that develops a long line of products, from refrigerants to air-conditioners, Daikin advocates comfortable living on the strength of advanced technologies. Daikin is present in USA and Canada, Europe and Russia, Middle East, Africa, Central Asia, Southeast Asia, Oceania and Latin America. We aim to serve our customers in each of these markets by providing optimal air-conditioning products. World’s No. Daikin India at a glance 2000: Daikin enters the Indian market in a JV with Usha Shriram Group at 80:20 stakes respectively as Daikin Shriram Airconditioning. 2002: Daikin introduces VRV technology in India. 2004: Daikin India becomes a wholly owned subsidiary of Daikin Industries Ltd., Japan. 2007: Daikin India relocates HQ to Gurgaon and commences business of McQuay chillers in India. 2008: Groundbreaking ceremony of Daikin India’s manufacturing base at Neemrana, Rajasthan. 2009: Production commences at manufacturing plant in Neemrana, Rajasthan. 2010: Fresh round of Rs. 250 crore investment. Thus taking it to a total of Rs. 743 crore. 2012: Production of High Wall Split air-conditioners with R-32 refrigerant commences. 2013: Fresh round of Rs. 330 crore investment. 11 2 10 8 1 9 3 7 4 12 13 5 6 1. USA 2. Canada 3. Latin America 4. East Asia 5. Southeast Asia 6. Oceania 7. Africa 8. Central Asia 9. Middle East 10. Europe 11. Russia 12. Japan 13. India The technology is used in many home appliances and controls electric voltage. current and frequency.What is Inverter Technology and how is it different from Non-Inverter Technology? An inverter is a device for converting frequency. inverter air-conditioners are more energy-saving and comfortable than non-inverter air-conditioners. An inverter has precise temperature control and as the set temperature is attained. An Inverter Type Air-Conditioner adjusts the speed of the compressor to control the gas Inverter Technology flow rate. . Non-inverter air-conditioners can only operate at a fixed capacity. In contrast. As a result. thereby consuming less current and power. non-inverter air-conditioners have a fixed cooling/heating capacity and can only control the indoor temperature by starting or stopping their compressors. Non-inverter air-conditioners stops and starts repeatedly. the unit adjusts its capacity to eliminate any temperature fluctuations. Inverter air-conditioners vary their cooling/heating capacity by adjusting the power supply frequency of their compressors. but it goes up sharply at the time of restart and thus it has high average power consumption and temperature variations. Variable capacity operation Inverter power control Raise frequency High-speed rotation High capacity Low-speed rotation Low capacity Compressor Power Source Lower frequency Non-inverter type air-conditioner Power Source Compressor Constant Speed rotation Fixed Capacity Inverter air-conditioners are able to vary their operating capacity. The power consumption and current goes down when the operation stops. What are the benefits of Inverter Air-Conditioners? Powerful Scenario: Indoor Temperature: 22°. This makes inverter models more energy saving than non-inverter models. Energy saving After the indoor temperature approaches the set temperature. which must repeatedly start or stop their compressors to maintain the room temperature. actual conditions and scenario may vary from the one shown. 22° 22° 22° 22° Temperature remains constant Non-inverter air-conditioner Comfortable 21° 23° Temperature rises and compressor starts again v 23° v Compressor stops v 21° v Inverter air-conditioners finely adjust capacity according to changes in the air-conditioning load and the difference between the indoor temperature and set temperature is small. Temperature fluctuates Compressor stops Inverter air-conditioners are more comfortable than non-inverter models Diagrams is used for illustrative purpose only. inverter control adjusts to low capacity operation to maintain this temperature. This gives higher comfort level than the noninverter air-conditioners. As a result. 02/03 . the set temperature can be reached more quickly. DAIKIN AIRCONDITIONING INDIA PVT. LTD. Set Temperature: 22° Inverter air-conditioner Inverter air-conditioners operate at maximum capacity as soon as they start up. A DC motor uses the power of magnets to attract and repel to generate rotation. The motor also provides improvements in operational efficiency of up to 40%. The DC motor allows fine rotation control. neodymium magnet1 and reluctance torque2. which enable even greater efficiency. 40% increase 20 Approx. 20% increase 0 200 300 400 500 600 700 800 900 1000 Motor speed (rpm) DC motor Motor efficiency (%) Efficiency (%) 80 80 70 60 AC motor *Data is based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.The technology What is DC inverter? DC motor for fan Daikin calls an inverter model that is equipped with a DC motor as DC inverter. A DC motor offers higher efficiency than an AC motor. Daikin’s internally embedded neodymium magnet generates strong magnetic field and 100 Recipient of Electric Science Promotion Award (Reluctance DC motor for compressor) Efficiency of Reluctance DC motor4 60 90 40 Approx. The reluctance DC motor uses two different types of torque. More than 20% 50 0 30 60 90 120 Rotational speed (rps) Reluctance DC motor Conventional DC motor Small load Large load Low capacity AC motor High capacity . compared to AC motor. A DC motor that is equipped with power neodymium magnets. These improvements are particularly noticeable in the low-speed range. Efficiency of DC motor for fan* (comparison with a conventional AC motor) Reluctance DC motor for compressor Daikin DC inverter models are equipped with the reluctance DC motor for compressor. is called a reluctance DC motor. This motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors. which reduces energy consumption. LTD. Reluctance DC motor Smooth sine wave of the inverter’s electric current eliminates pulsation and high harmonic noise. Sine wave Neodymium magnets are used in the pink-coloured area. the swing compressor decreases friction and vibration. Pulse amplitude PAM control reduces energy loss by controlling how often the converter switches on and off Integral piston of blade and roller The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor. These advantages provide quiet and efficient operation. Ferrite magnet Neodymium magnet 1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.high torque resulting in high operational efficiency with less electricity consumption. It also prevents leakage of refrigerant gas during compression. 2 The torque created by the change in power between the iron and magnet pads. It is more efficient at low frequencies most commonly used by air-conditioners3 improving efficiency by approximately 20%. Swing compressor Swing bush Refrigerant gas Thanks to its smooth rotation. This is the range in which air-conditioners operate for the longest periods. thus helping in better efficiency. 3 The frequency range used by air-conditioners during periods of stable operation. 04/05 . 4 Data is based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products. . Highly effective inverter. that can generate the control signal which is closer to the sine wave. Daikin was presented 32nd Chairman’s award by the Japan society for the promotion of the machine industry for swing compressor DAIKIN AIRCONDITIONING INDIA PVT. Daikin aims to develop systems that improve comfort levels. while having low environmental impact. Refrigerant choice is a key factor in the drive to maximise energy efficiency and to minimise the global warming impact of system. a next generation refrigerant As part of its commitment to the environment. .R-32. R-32. a next generation refrigerant is the most balanced refrigerant for use in both residential and commercial air-conditioners. 000 472 500 20 0 HCFC HFC HFC 22 410A 32 Charging ratio (%) GWP Better performance 2.000 100 100 x 1.500 1. More specifically the pressure loss is lower with R-32 than R-22 or R-410A for the same.000 70 = 60 40 500 0 0 HCFC HFC HFC 22 410A 32 1.500 120 2. the use of charging volume can be 30% less than R-22 or R-410A. LTD. which makes it easy to recycle.810 1. 06/07 .6 times that of R-22 and R-410A. The use of R-32 in the new Daikin range offers end-users the opportunity to benefit from class-leading energy efficiencies. The liquid density of R-32 is 10% lower thus the piping diameter can be smaller.090 2.500 2.027. while lowering the environmental impact of the refrigerants. compared to R-410A’s Modified GWP of 2. Also R-32 is a single component refrigerant.Environmental impact ~1. It is because of these reasons that R-32 offers the lowest total emissions and best overall life-cycle climate performance. 2.6 times more cooling compared to R410A ~5% more power savings compared to R410A ~30% less refrigerant charging volume as compared to R410A & R22 Better performance at higher temperature as compared to R22 (Low Derating) Data based on studies conducted under test conditions R-32 has zero Ozone Depletion Potential (ODP) and Modified Global Warming Potential (GWP) of 472. Theoretical Modified GWP 2. excellent air quality and high comfort levels.000 675 80 The potential refrigeration capacity of R-32 is 1.810 HCFC HFC HFC 22 410A 32 Theoretical Modifide GWP HFC32 is the most balanced refrigerant Ozone Ozone Economy 5 4 5 4 3 3 3 3 1 HFC32 Ozone 5 4 2 Safety Ozone 5 4 Economy 2 LCCP Energy 1 Safety HFC410A LCCP Energy Economy 2 1 Safety HFO1234YF LCCP Energy Economy 2 1 Safety LCCP Energy Propane (HFC290) DAIKIN AIRCONDITIONING INDIA PVT. As a result.500 1.027 97 1. 4-5. Height Difference Cooling Heating Indoor Unit Outdoor Unit Rated (Min .5 Model Name Capacity Inverter powerful operation . piping length 7.86 5.Max) Rated Cooling Heating Cooling Heating Kw Kw FTXR28KVMA RXR28KVMA 2.1 1470 (260~1800) 1490 (230~1770) 3. 6° CWB.75.1-7.5 m.30~5.2-3. 27° CDB.9-5.Max) Cooling Heating Cooling Heating Cooling Heating Rated Rated (Min .60) 3.2 5.4 438 dB (A) 39 / 33 / 26 / 23 41 / 35 / 28 / 25 mm kg RXR28KVMA Cooling Heating Cooling Heating Type dB (A) mm kg °CDB °CWB m 46/-46/-- IDU Colour: White FTXR42KVMA RXR42KVMA 4. bacteria and viruses For the complete feature list please refer pages 30-31.20 (1.20) 7.4 438 12.03 FTXR28KVMA m³/min cfm m³/min cfm 11.08 (1.60) 1 phase.57 (1.Max) Rated (Min .5 m. These values are normally somewhat higher during actual operation as a result of ambient conditions. piping length 7.60) 5. FTXR50KVMA RXR50KVMA 4.7-5. 1.Boosts cooling/heating performance Power Supply Running Current Power Consumption COP Indoor Unit Front Panel Colour Airflow rate Cooling breeze operation Comfortable cooling breeze Mould proof stick .2-7. and 2. dehumidification. 2.50) 5.Humidification.Prevents buildup of mould.55~4.55~3. 35° CDB. purification & ventilation Ton: 0.1 4.2. These are anechoic conversion values.30~5.9 455 5 steps. 50Hz 5. 20° CDB. above with 5m piping length.3-3.8 570 (250~800) 710 (220~1410) 4. 3.55~5.3-7.97 FTXR50KVMA 13. Heating capacity is based on: indoor temp.32 3. Fan Speed Sound Levels (H/M/L/SL) Dimensions (HxWxD) Machine Weight Outdoor Unit Casing colour Compressor Sound Levels (H/SL) Dimensions (HxWxD) Machine Weight Operation range Max.88 (1.9-3.91 (1.FTXR Series Heat pump PERFECTION IN AIR-CONDITIONING Total comfort .1 392 12. 24° CWB.93 4.3 470 14 494 44 / 37 / 29 / 26 44 / 38 / 31 / 28 RXR50KVMA 48/-50/-- .0-3.00) A A W W W/W W/W 3.3-5. 1. outdoor temp. 19° CWB.2-7. outdoor temp. Piping Length Max.34 FTXR42KVMA White 12.6 1070 (260~1320) 1170 (220~1600) 3.0 7.30~6. quiet and Automatic 42 / 35 / 27 / 24 42 / 36 / 29 / 26 305 x 890 x 209 14 RXR42KVMA Ivory White Hermetically sealed swing type 48/-48/-693 x 795 x 285 48 10°C to 43°C -20°C to 18°C (Humidify -10 to 24) 10 8 Measurement conditions: 1.77 (1. Cooling capacity is based on: indoor temp. 220-240V. 7° CDB. Sound levels are based on temperature conditions 1. 3) 5.0 (1.7~5.0 (1. LTD.4 Model Name Capacity Comfortable mode .6 7. 50Hz 3.46 3. Heating capacity is based on: indoor temp.2-6. 3. 220-240V. 1.8) 4.5 (1. Piping Length Max.9 5.75.Adjusts cooling according to human presence Fan Speed Sound Levels (H/M/L/SL) Dimensions (HxWxD) Machine Weight Outdoor Unit Casing colour Compressor Sound Levels (H/SL) Saranet filter .8-4. 20° CDB. Sound levels are based on temperature conditions 1.04 FTXG25JV1BA FTXG35JV1BA Silver 8.Max) Rated Cooling Heating Intelligent eye .0-2.1 311 357 9.5 (1.1 5. quiet and Automatic 38 / 32 / 25 /22 42 / 34 / 26 / 23 39 / 34 / 28 / 25 42 / 36 / 29 / 26 295 x 915 x 155 11 RXG25K3V1B RXG35K3V1B Ivory White Hermetically sealed swing type 46/43 48/44 47/44 48/45 550 x 765 x 285 34 -10°C to 46°C -15°C to 20°C 20 15 FTXG50JV1BA RXG50K3V1B 5. 7° CDB.63 FTXG50JV1BA 10.0) 1phase.FTXG Series Heat pump IT’S ALL ABOUT DESIGN Indoor unit quite operation Cools/heats quietly Ton: 0.2500) 3.4 (1.3-5. DAIKIN AIRCONDITIONING INDIA PVT.820) 890 (360 .4-7.1-4.8 (1. These values are normally somewhat higher during actual operation as a result of ambient conditions.8 1560 (450 .2-4.4 402 44 / 40 / 35 / 32 44 / 40 / 35 / 32 RXG50K3V1B 735 x 825 x 300 48 30 20 Measurement conditions: 1. Dimensions (HxWxD) Machine Weight Operation range Max. 6° CWB.5) 7. 27° CDB.5) FTXG35JV1BA RXG35K3V1B 3.8 10.21 3.3~4.7~6. 08/09 .6 4. above with 5m piping length.0) 3. and 2. 2.1500) 4. outdoor temp. 1.Max) Rated (Min . piping length 7. 19° CWB.4~3.36 4.5 m.1-6. 35° CDB.1320) 990 (320 .93 4.Provides gentle and comfortable environment Power Supply Running Current Power Consumption COP Indoor Unit Front Panel Colour Airflow rate Cooling Heating Indoor Unit Outdoor Unit Rated (Min .5 m. These are anechoic conversion values. Cooling capacity is based on: indoor temp.4-4. outdoor temp.1 560 (350 .Removes airborne dust particles for cleaner air supply For the complete feature list please refer pages 30-31.1220) 780 (320 .3~3. Height Difference Cooling Heating Kw Kw A A W W W/W W/W m³/min cfm m³/min cfm dB (A) mm kg Type Cooling Heating Cooling Heating dB (A) mm kg °CDB °CWB m IDU Colour: Sandblasted Aluminium FTXG25JV1BA RXG25K3V1B 2.9-6.1880) 1600 (520 .Max) Cooling Heating Cooling Heating Cooling Heating Rated Rated (Min . 24° CWB.2-3.3 364 11. piping length 7.6-5.8 339 389 5 steps.6 10.4~5. 6º CWB.980 (440-2.70 3.4(614) 21.040 (400-2.7) 5.-Max) Rated (Min. 1. 1.390) 830 (290-1.730) 3.2-4.340) 1.550) 1. 2. 230 V.5) 8.5 (1. outdoor temp.080 (290-1.1 4.4 (614) 5 steps.Circulates a cloud of cool/warm air right to the corners of even large spaces Running Current Power consumption Indoor Unit Front panel Colour Airflow rate (H) Sound Levels (H/L/SL) Rated A Rated (Min. 1.63 3.0) FTXS50FVMA FTXS60FVMA RXS50FVMA RXS60FVMA 5.01 3.2-5.7 6.1 9 600 (300-800) 1. piping length 7. 2.03 4.0 (1.-Max) FTXS25EVMA RXS25EBVMA 2.600 (400-2. Cooling Heating Cooling Heating Cooling Heating Fan speed Sound Levels (H/SL) Inverter powerful operation Faster cooling/heating Kw Kw Power Supply COP Indoor unit quiet operation Quiet performance Cooling Heating Indoor Unit Outdoor Unit Rated (Min.7-6.5.080) 1.0 (1.3-8.520 (520-3.7-6.2 Model Name Capacity 3D airflow . 7º CDB. 20º CDB. and 2.Senses human movement for temperature adjustment Ton: 0.530) 2. Sound levels are based on temperature conditions 1.7) 7.0 (1.3-10.020 (300-1. piping length Max.0 (1.-Max) W Rated W/W Cooling Heating m3/min(cfm) Cooling Heating dB (A) Dimensions (HxWxD) Machine weight Outdoor Unit Casing colour Compressor mm Kg Type Cooling Heating dB (A) Cooling Heating mm Kg ºCDB ºCWB m m Dimensions (HxWxD) Machine weight Operation Range Max. 50Hz 3.4 (1.5m. piping length 7. 24° CWB.5 (1.8 4.2 (2. 3.5m.1 2.7(519) 16.23 3.200) 2.360 (570-3.9 (314) 14. Heating capacity is based on: indoor temp. These are anechoic conversion values. FTXS71FVMA RXS71FVMA 7. above with 5m piping length.8.8) 4. 27º CDB.FTXS Series Heat pump BEYOND IMAGINATION Intelligent eye .4 11.75.0) 3.2(572) 9.7-8.17 3.7-7.5) IDU Colour: White FTXS35EVMA RXS35EBVMA 3.3 4.2-3.9 7. 35° CDB.200) 1. These values are normally somewhat higher during actual operation as a result of ambient conditions.0) 6.0) 10.7 (342) 16.4 (332) 9. 19º CWB.1 (2.810) 4. height difference For the complete feature list please refer pages 30-31.0) 1 phase.550 (440-2.2-3.25 FTXS71FVMA 17. outdoor temp.10 3.050 x 238 9 12 RXS25EBVMA RXS35EBVMA RXS50FVMA RXS60FVMA Ivory White Hermetically sealed swing type 46 / 43 47 / 44 49 / 46 47 / 44 48 / 45 49 / 46 550 x 765 x 285 735 x 825 x 300 34 48 10 to 46 -15 to 20 -15 to 18 20 30 15 20 Measurement conditions: 1. Cooling capacity is based on: indoor temp.2 (572) 17. quiet and automatic 37 / 25 / 22 38 / 26 / 23 44 / 35 / 32 45 / 36 / 33 37 / 28 / 25 38 / 29 / 26 42 / 33 / 30 44 / 35 / 32 283 x 800 x 195 290 x 1.9 8.7 (307) 8.43 FTXS25EVMA FTXS35EVMA FTXS50FVMA FTXS60FVMA White 8.5 (759) 46 / 37 / 34 46 / 37 / 34 RXS71FVMA 52 / 49 52 / 49 770 x 900 x 320 71 .43 3.8 (1. 9 / 6. 1.5) 37/33/28/25 RKM25QRV16 550x765x285 29(36) 47 R32 10 20 15 9.4 10~46 Measurement conditions: 1.55 FTKM35QRV16 White 283x800x198 8 (12) 9.2) 8500 (3400~10900) 650 (220~900) 3.7(8.35~3.4 FTKM60QRV16 White 310x1100x239 13 (18) 18. 19º CWB.No extra cost New smartphone connectivity feature (optional) Indoor unit Outdoor unit Model name Coand airflow .2 (2.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 7. 35° CDB.7 / 6. 2.1) 45/41/35/30 RKM60QRV16 595x845x300 39 (47) 49 R32 10 30 20 12.8 FTKM50QRV16 White 310x1100x239 13 (18) 17. 10/11 . dBA Cooling mm kg dBA Charge-less Max.0~7.5/ 6.8 (2. Cooling capacity is based on: indoor temp. 1.1 (2.0) 11900 (3400~13600) 964 (220~1300) 3.5.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 6.11) 7. DAIKIN AIRCONDITIONING INDIA PVT. 24° CWB.0~4. length Max.6) 42/38/35/28 RKM50QRV16 595x845x300 38(46) 47 R32) 10 30 20 12.Senses human movement for temperature adjustment Titanium apatite photocatalytic air purifying filter .0~3.52) 5.55~3. LTD.8.1~8.0) 17100 (3400~20500) 1315 (370~1700) 3.) Intelligent eye .0 (1.FTKM Series Cooling only PATH-BREAKING SERIES Ton: 0.1(15.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 3.56) 3.6(8.Improves circulation of cold air Power supply Power supply intake Cooling capacity kW Btu/h Rated (min.08) 4.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 5. These are anechoic conversion values.5/ 6. Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling W W/W A Cooling mm kg m3/min.0) 46/42/36/32 RKM71QV16 735x825x300 49 (59) 52 R32 10 30 20 15.07 FTKM25QRV16 White 283x800x198 8 (12) 9.0) 24200 (7200~27300) 2220 (530~3300) 3. height Gas/Liquid Cooling m m m mm DB IDU Colour: White FTKM25QRV16 RKM25QRV16 FTKM35QRV16 RKM35QRV16 FTKM50QRV16 RKM50QRV16 FTKM60QRV16 RKM60QRV16 FTKM71QRV16 RKM71QV16 1 50Hz 230V (220-240V) Outdoor unit 2. Sound levels are based on temperature conditions 1 above.6 (4.63 (4.5 (1.5 (1.4(17. These values are normally somewhat higher during actual operation as a result of ambient conditions.0~6. 27º CDB.~max.0 (1.6) 39/34/29/26 RKM35QRV16 550x765x285 32(38) 48 R32 10 20 15 9.70~3.0) 20500 (3400~23900) 1666 (230~2250) 3.6 FTKM71QRV16 White 310x1100x239 13 (18) 20.42~3.Absorbs bacteria and viruses and eliminates odor For the complete feature list please refer pages 30-31.7 / 6.75.85 (4.4(14. piping length 5m.96) 9. 2.55~3. outdoor temp.2 Stabiliser free operation . 1. 0) 20500 (3400~23900) 1666 (230~2250) 3.35~3. These values are normally somewhat higher during actual operation as a result of ambient conditions.5/ 6.DTKM Series Cooling only PATH-BREAKING SERIES Ton: 0.0 (1.Absorbs bacteria and viruses and eliminates odor For the complete feature list please refer pages 30-31.56) 3.0 (1.7(8. These are anechoic conversion values.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 3. outdoor temp.0~7.4 10~46 Measurement conditions: 1. . 1.7 / 6. Power supply intake kW Btu/h Rated (min.Senses human movement for temperature adjustment Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Titanium apatite photocatalytic air purifying filter .63 (4.85 (4. length Max.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 5.~max.6 (4.5) 37/33/28/25 RKMD25QRV16 550x765x285 29(36) 47 R32 10 20 15 9.8 (2.5 (1.5/ 6.2) 8500 (3400~10900) 650 (220~900) 3. Cooling capacity is based on: indoor temp.0~6. 2.70~3.5. 35° CDB.08) 4.6(8.11) 7. dBA Cooling mm kg dBA Charge-less Max.8 DTKM50QRV16 White 310x1100x239 13 (18) 17. 19º CWB.0~4.5 (1.1(15.4(14.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 6.55~3.7 / 6.1) 45/41/35/30 RKMD60QRV16 595x845x300 39 (47) 49 R32 10 30 20 12.52) 5. height Gas/Liquid Cooling m m m mm DB IDU Colour: White DTKM25QRV16 RKMD25QRV16 DTKM35QRV16 RKMD35QRV16 DTKM50QRV16 RKMD50QRV16 DTKM60QRV16 RKMD60QRV16 1 50Hz 230V (220-240V) Outdoor unit 2.4 DTKM60QRV16 White 310x1100x239 13 (18) 18.No extra cost Indoor unit Outdoor unit Model name Power supply New good sleep off timer Avoids excessive cooling and enjoy uninterrupted sleep Cooling capacity Intelligent eye .75. Sound levels are based on temperature conditions 1 above.) Piping connection Operation limit Cooling W W/W A Cooling mm kg m3/min.0~3.0) 17100 (3400~20500) 1315 (370~1700) 3. 1.55 DTKM35QRV16 White 283x800x198 8 (12) 9.6) 42/38/35/28 RKMD50QRV16 595x845x300 38(46) 47 R32 10 30 20 12. piping length 5m.07 DTKM25QRV16 White 283x800x198 8 (12) 9.0) 11900 (3400~13600) 964 (220~1300) 3. 1.55~3.8 New smartphone connectivity feature (optional) Stabiliser free operation .6) 39/34/29/26 RKMD35QRV16 550x765x285 32(38) 48 R32 10 20 15 9. 27º CDB. 24° CWB. 11) 7.0) 11900 (3400~13600) 964 (220~1300) 3.70~3.55 ATKM35QRV16 White 283x800x198 8 (12) 9.5/ 6. dBA Cooling mm kg dBA Charge-less Max.5.56) 3.8 ATKM50QRV16 White 310x1100x239 13 (18) 17.Senses human movement for temperature adjustment Silver particle anti-bacterial filter .0~6.0) 17100 (3400~20500) 1315 (370~1700) 3.55~3. 1. 1.0~7. length Max.Kills bacteria and deodorises the air Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling W W/W A Cooling mm kg m3/min.0~4.6) 42/38/35/28 RKMA50QRV16 595x845x300 38(46) 47 R32 10 30 20 12.5 (1.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 5.0 (1.Improves circulation of cold air Power supply intake Cooling capacity kW Btu/h Rated (min. 27º CDB. height Gas/Liquid Cooling m m m mm DB IDU Colour: White ATKM25QRV16 RKMA25QRV16 ATKM35QRV16 RKMA35QRV16 ATKM50QRV16 RKMA50QRV16 ATKM60QRV16 RKMA60QRV16 1 50Hz 230V (220-240V) Outdoor unit 2.4 ATKM60QRV16 White 310x1100x239 13 (18) 18.ATKM Series Cooling only PATH-BREAKING SERIES Ton: 0. 12/13 .4 10~46 1 50Hz 230V (220-240V) Outdoor unit 6.0 (1.6 (4.5 (1. Sound levels are based on temperature conditions 1 above.55~3.63 (4. outdoor temp.7 / 6.0~3.5) 37/33/28/25 RKMA25QRV16 550x765x285 29(36) 47 R32 10 20 15 9.1(15. 2.5/ 6.8 New smartphone connectivity feature (optional) Stabiliser free operation .6(8. 35° CDB. For the complete feature list please refer pages 30-31.4(14.0) 20500 (3400~23900) 1666 (230~2250) 3.8 (2.6) 39/34/29/26 RKMA35QRV16 550x765x285 32(38) 48 R32 10 20 15 9. LTD.) Intelligent eye . 24° CWB. These are anechoic conversion values. Cooling capacity is based on: indoor temp.4 10~46 1 50Hz 230V (220-240V) Outdoor unit 3.~max.1) 45/41/35/30 RKMA60QRV16 595x845x300 39 (47) 49 R32 10 30 20 12.2) 8500 (3400~10900) 650 (220~900) 3. 1.07 ATKM25QRV16 White 283x800x198 8 (12) 9.4 10~46 Measurement conditions: 1.No extra cost Indoor unit Outdoor unit Model name Power supply Coand airflow .08) 4.7(8. DAIKIN AIRCONDITIONING INDIA PVT. piping length 5m. These values are normally somewhat higher during actual operation as a result of ambient conditions. 19º CWB.85 (4.75.52) 5.35~3.7 / 6. 7) 17100 (8500~19400) 1445 (710~1750) 3.46 (3.4 19. 1.4 19.4 9.56) 3. 1.05) 3.No extra cost New smartphone connectivity feature (optional) Indoor unit Outdoor unit Model name Coand airflow .8 10.2 Stabiliser free operation .40 (3.Quickly maximises the cooling Titanium apatite photocatalytic air purifying filter .4~46 Measurement conditions: 1. 1.1~7. Sound levels are based on temperature conditions 1 above.Improves circulation of cold air Power supply Power supply intake Cooling capacity Power chill operation .0 (2. 35° CDB.5) 20500 (8500~22900) 24200(7200~25600) 1765 (720~2220) 2365(600~3100) 3.4(14.4 19.9(8.~max. Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min. height Gas/Liquid Cooling m m m mm DB Rated (min. dBA Cooling mm kg dBA Charge-less Max.Absorbs bacteria and viruses and eliminates odor For the complete feature list please refer pages 30-31.0) 8500 (6100~10900) 11600 (6100~13600) 723 (475~900) 982 (475~1310) 3.5) 9.1(15.FTKP Series Cooling only AIR-CONDITIONING REDEFINED Ton: 0.4(17.5 (1. 2.7 / 6.8~4.) FTKP25QRV16 RKP25QRV16 FTKP35QRV16 RKP35QRV16 1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 2.46 (3. 24° CWB.02) 3 (3.2) 3.0) 47/43/38/-47/43/39/-RKP60QRV16 RKP71QRV16 595x845x300 595x845x300 38(46) 39(47) 54/-55/-R32 R32 10 10 30 30 20 20 12.74 FTKP25QRV16 FTKP35QRV16 White White 283x800x198 283x800x198 8 (12) 8 (12) 9.8) 37/33/28/25 40/36/31/26 RKP25QRV16 RKP35QRV16 550x765x285 550x765x285 29(36) 32(38) 49/-49/-R32 R32 10 10 20 20 15 15 9.8.4~46 FTKP50QRV16 RKP50QRV16 1 50Hz 230V (220-240V) Outdoor unit 5. 19º CWB.4 FTKP60QRV16 FTKP71QRV16 White White 310x1100x239 310x1100x239 13 (18) 13 (18) 18.7 / 6. outdoor temp. These values are normally somewhat higher during actual operation as a result of ambient conditions.4~46 19.79~3.75.5~5.49 4.5~6.9/ 6. length Max.4 15. Cooling capacity is based on: indoor temp.0 (2. piping length 5m. IDU Colour: White FTKP60QRV16 RKP60QRV16 FTKP71QRV16 RKP71QRV16 1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 6. 27º CDB.6) 45/40/35/-RKP50QRV16 595x845x300 41(48) 50/-R32 10 30 20 12.5/ 6.46 (3.5/ 6.26) 6.42) 7.4 (1.1) 20. 2.47~3.52~3.4~46 19.50~2.5 FTKP50QRV16 White 310x1100x239 13 (18) 17.7) 7.6(8.8~3.1 (2. These are anechoic conversion values.5.79~3.4~46 . 1~7.79~3.47~3. These are anechoic conversion values. LTD.4 19.6) 45/40/35/-RKPD50QRV16 595x845x300 41(48) 50/-R32 10 30 20 12.7) 17100 (8500~19400) 1445 (710~1750) 3.46 (3.5 DTKP50QRV16 White 310x1100x239 13 (18) 17.8~3. Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min. Cooling capacity is based on: indoor temp.05) 3.4~46 19.4(17.No extra cost New smartphone connectivity feature (optional) Indoor unit Outdoor unit Model name New good sleep-off timer Avoids excessive cooling and enjoy uninterrupted sleep Power chill operation .52~3.2) 3.5~6.4~46 Measurement conditions: 1.8 10. piping length 5m.75.4 DTKP60QRV16 DTKP71QRV16 White White 310x1100x239 310x1100x239 13 (18) 13 (18) 18.0 (2.Absorbs bacteria and viruses and eliminates odor For the complete feature list please refer pages 30-31. 19º CWB.56) 3.4~46 19.42) 7.7 / 6.4~46 IDU Colour: White DTKP60QRV16 RKPD60QRV16 DTKP71QRV16 RKPD71QRV16 1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 6.5 (1. These values are normally somewhat higher during actual operation as a result of ambient conditions.02) 3 (3.1 (2.1(15. 27º CDB.46 (3.0) 47/43/38/-47/43/39/-RKPD60QRV16 RKPD71QRV16 595x845x300 595x845x300 38(46) 39(47) 54/-55/-R32 R32 10 10 30 30 20 20 12. 24° CWB.8.50~2.) DTKP25QRV16 RKPD25QRV16 DTKP35QRV16 RKPD35QRV16 1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 2.4 (1. 35° CDB.~max.5/ 6.4 19.Quickly maximises the cooling Titanium apatite photocatalytic air purifying filter . DAIKIN AIRCONDITIONING INDIA PVT.5.6(8. Sound levels are based on temperature conditions 1 above.4 15.9(8.0 (2.5) 20500 (8500~22900) 24200(7200~25600) 1765 (720~2220) 2365(600~3100) 3.9/ 6.74 DTKP25QRV16 DTKP35QRV16 White White 283x800x198 283x800x198 8 (12) 8 (12) 9. height Gas/Liquid Cooling m m m mm DB Rated (min.4~46 DTKP50QRV16 RKPD50QRV16 1 50Hz 230V (220-240V) Outdoor unit 5.DTKP Series Cooling only AIR-CONDITIONING REDEFINED Ton: 0.2 Stabiliser free operation .4 19. length Max.5/ 6.4(14. 2. 14/15 . 1.5) 9. 1.8~4.46 (3.1) 20. outdoor temp.4 9.49 4.8) 37/33/28/25 40/36/31/26 RKPD25QRV16 RKPD35QRV16 550x765x285 550x765x285 29(36) 32(38) 49/-49/-R32 R32 10 10 20 20 15 15 9. 2. dBA Cooling mm kg dBA Charge-less Max.0) 8500 (6100~10900) 11600 (6100~13600) 723 (475~900) 982 (475~1310) 3.26) 6.79~3. 1.7) 7.7 / 6.5~5.40 (3. 75.26) 6.46 (3.5 ATKP50QRV16 White 310x1100x239 13 (18) 17.1) 20.4~46 19.5/ 6. 1.1 (2.Kills bacteria and deodorises the air For the complete feature list please refer pages 30-31.9(8.4 19.4(14.42) 7.Reduces power consumption Power supply Power supply intake Cooling capacity Power chill operation .4 ATKP60QRV16 ATKP71QRV16 White White 310x1100x239 310x1100x239 13 (18) 13 (18) 18.5) 9.7 / 6.6) 45/40/35/-RKPA50QRV16 595x845x300 41(48) 50/-R32 10 30 20 12.0 (2.46 (3.7) 17100 (8500~19400) 1445 (710~1750) 3. 2.4 (1.0) 47/43/38/-47/43/39/-RKPA60QRV16 RKPA71QRV16 595x845x300 595x845x300 38(46) 39(47) 54/-55/-R32 R32 10 10 30 30 20 20 12. These values are normally somewhat higher during actual operation as a result of ambient conditions.8 10.49 4.4~46 .4~46 Measurement conditions: 1.4~46 ATKP50QRV16 RKPA50QRV16 1 50Hz 230V (220-240V) Outdoor unit 5. These are anechoic conversion values.2 Stabiliser free operation . 35° CDB.8) 37/33/28/25 40/36/31/26 RKPA25QRV16 RKPA35QRV16 550x765x285 550x765x285 29(36) 32(38) 49/-49/-R32 R32 10 10 20 20 15 15 9.47~3.) ATKP25QRV16 RKPA25QRV16 ATKP35QRV16 RKPA35QRV16 1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 2.79~3.05) 3.9/ 6.1(15. length Max.5) 20500 (8500~22900) 24200(7200~25600) 1765 (720~2220) 2365(600~3100) 3. Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min. dBA Cooling mm kg dBA Charge-less Max.Quickly maximises the cooling Silver particle anti-bacterial filter .No extra cost New smartphone connectivity feature (optional) Indoor unit Outdoor unit Model name Econo mode .4 15. Sound levels are based on temperature conditions 1 above.56) 3.5~5.4(17.7) 7.0) 8500 (6100~10900) 11600 (6100~13600) 723 (475~900) 982 (475~1310) 3. 1.74 ATKP25QRV16 ATKP35QRV16 White White 283x800x198 283x800x198 8 (12) 8 (12) 9.8~3.1~7. piping length 5m. outdoor temp.7 / 6. 2.5/ 6.6(8.5 (1.46 (3. 27º CDB.40 (3.~max. IDU Colour: White ATKP60QRV16 RKPA60QRV16 ATKP71QRV16 RKPA71QRV16 1 50Hz 230V 1 50Hz 230V (220-240V) (220-240V) Outdoor unit Outdoor unit 6.4~46 19.8. 19º CWB.50~2.4 19.52~3.ATKP Series Cooling only AIR-CONDITIONING REDEFINED Ton: 0.2) 3.5.4 9.5~6. 24° CWB.0 (2.4 19. Cooling capacity is based on: indoor temp. height Gas/Liquid Cooling m m m mm DB Rated (min.02) 3 (3.8~4.79~3. 1. 7 / 6.FTKH Series Cooling only A NEW AGE OF AIR-CONDITIONING Ton: 1.0) 8. Sound levels are based on temperature conditions 1 above.5) 12000 (6000~12000) 3.32 FTKH50QRV16 White 310x1100x239 13 (18) 17. height Gas/Liquid Cooling kW Btu/h W/W A Cooling mm kg m3/min. 16/17 .4~3.0 (3. Cooling capacity is based on: indoor temp. 1.4~46 1 50Hz 230V (220-240V) Outdoor unit 6.75~3.7 / 6. 19º CWB.8) 40/36/31/26 RKH35QRV16 550x765x285 26(33) 51/-R32 10 20 15 9.5/ 6.0.4~46 1 50Hz 230V (220-240V) Outdoor unit 5.Quickly maximises the cooling Cooling capacity Rated (min.1) 47/43/38/-RKH60QRV16 595x845x300 35(43) 56/-R32 10 30 20 12. These values are normally somewhat higher during actual operation as a result of ambient conditions. piping length 5m.5.1 FTKH35QRV16 White 283x800x198 8 (12) 9. 35° CDB.0 (3.0) 17100 (8550~17100) 3.0) 7.83 FTKH60QRV16 White 310x1100x239 13 (18) 18. DAIKIN AIRCONDITIONING INDIA PVT.) COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L/SL Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound H/L Refrigerant Piping length Piping connection Operation limit Power supply intake Charge-less Max.4~46 Measurement conditions: 1.0) 5. 27º CDB.0 (3.5~5.6) 45/40/35/-RKH50QRV16 595x845x300 34 (42) 54/-R32 10 20 10 12. 2.4(14.4 19.Improves circulation of cold air Power chill operation . 24° CWB.~max.0) 20500 (10250~20500) 3.0~6.5 (1.4~3.9(8.Reduces power consumption For the complete feature list please refer pages 30-31. These are anechoic conversion values.1(15. dBA Cooling mm kg dBA Cooling m m m mm DB IDU Colour: White FTKH35QRV16 RKH35QRV16 FTKH50QRV16 RKH50QRV16 FTKH60QRV16 RKH60QRV16 1 50Hz 230V (220-240V) Outdoor unit 3. length Max.4 19. LTD.8 Stabiliser free operation No extra cost New smartphone connectivity feature (optional) Indoor unit Outdoor unit Model name Power supply Coand airflow .0 (2.5~3. Econo mode . outdoor temp.0 (3. 1.4 19. 9/ 6. length Max.1) 44/41/35 RF50QRV16 595x845x300 44(54) 50 R32 10 20 10 15.4 8. 19º CWB. 1.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. outdoor temp.Absorbs bacteria and viruses and eliminates odor Good sleep off timer . Cooling capacity is based on: indoor temp.6) 39/35/29 RF35QRV16 550x765x285 33(41) 49 R32 10 20 15 12.7/ 6. 27º CDB. height Gas/Liquid Measurement conditions: 1.4 19.3 FTF35QRV16 White 283x800x198 8 (12) 9.0) 47/41/35 RF60QRV16 595x845x300 45(55) 56 R32 10 20 10 15.No extra cost Ton: 1.5.4~50 1 50Hz 230V (220-240V) Outdoor unit 5.35 11450 930 3.4(17.1 (15. 1. 24° CWB. Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min.4~50 1 50Hz 230V (220-240V) Outdoor unit 6.9 / 6.4 21800 1880 3. piping length 5m. 35° CDB.6 FTF60QRV16# White 310x1100x239 13 (18) 20.6 FTF50QRV16 White 310x1100x239 13 (18) 18. Sound levels are based on the temperature condition in 1above.4 19. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max.8 ton model For the complete feature list please refer pages 30-31.4~46 # 4 Star .6 4.Improves circulation of cold air Indoor unit Outdoor unit Model name Power supply Power supply intake Cooling capacity Titanium apatite photocatalytic air purifying filter .Avoids excessive cooling and enjoy uninterrupted sleep Upto 50°C operating range Cools at high temperature* *Not applicable for 1.6 6.7(8.2 17750 1445 3. 2.8 Coand airflow . IDU Colour: White FTF35QRV16 RF35QRV16 FTF50QRV16 RF50QRV16 FTF60QRV16# RF60QRV16 1 50Hz 230V (220-240V) Outdoor unit 3.4 19.FTF Series Cooling only EXPERIENCE ELEGANCE IN AIR-CONDITIONING Stabiliser free operation . length Max.6) 39/35/29 RFD35QRV16 550x765x285 33(41) 49 R32 10 20 15 12.4~50 1 50Hz 230V (220-240V) Outdoor unit 6.1 (15.9 / 6. 27º CDB.8 Ton model For the complete feature list please refer pages 30-31.6 DTF60QRV16 White 310x1100x239 13 (18) 20.6 DTF50QRV16 White 310x1100x239 13 (18) 18. 35° CDB. 1. piping length 5m.9/ 6.1) 44/41/35 RFD50QRV16 595x845x300 44(54) 50 R32 10 20 10 15. outdoor temp.7(8.DTF Series Cooling only EXPERIENCE ELEGANCE IN AIR-CONDITIONING Stabiliser free operation . These values are normally somewhat higher during actual operation as a result of ambient conditions.3 DTF35QRV16 White 283x800x198 8 (12) 9.4 19. DAIKIN AIRCONDITIONING INDIA PVT.Avoids excessive cooling and enjoy uninterrupted sleep Upto 50°C operating range Cools at high temperature* *Not applicable for 1.Quickly maximises the cooling Indoor unit Outdoor unit Model name Power supply Power supply intake Cooling capacity Titanium apatite photocatalytic air purifying filter .6 4. 18/19 . Cooling capacity is based on: indoor temp. Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min.4 21800 1880 3. height Gas/Liquid IDU Colour: White DTF35QRV16 RFD35QRV16 DTF50QRV16 RFD50QRV16 DTF60QRV16 RFD60QRV16 1 50Hz 230V (220-240V) Outdoor unit 3. 2.Absorbs bacteria and viruses and eliminates odor Good sleep off timer . LTD.These are anechoic conversion values.2 17750 1445 3. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max.No extra cost Ton: 1 1.0) 47/41/35 RFD60QRV16 595x845x300 45(55) 56 R32 10 20 10 15.4 19.6 6. 19º CWB.7/ 6.8 Power chill operation .4(17. 24° CWB.5.4 19.4 8.4~46 Measurement conditions: 1.4~50 1 50Hz 230V (220-240V) Outdoor unit 5.35 11450 930 3. Sound levels are based on the temperature condition in 1above. 6 ATF60QRV16 White 310x1100x239 13 (18) 20.4 19.8 ton model For the complete feature list please refer pages 30-31. Cooling capacity is based on: indoor temp.4 19.9 / 6.6 6. IDU Colour: White ATF35QRV16 RFA35QRV16 ATF50QRV16 RFA50QRV16 ATF60QRV16 RFA60QRV16 1 50Hz 230V (220-240V) Outdoor unit 3. piping length 5m.6 ATF50QRV16 White 310x1100x239 13 (18) 18. 2.35 11450 930 3.6 4.4(17.5.3 ATF35QRV16 White 283x800x198 8 (12) 9.These are anechoic conversion values.9/ 6. length Max. These values are normally somewhat higher during actual operation as a result of ambient conditions. 24° CWB.7(8. 35° CDB. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max. height Gas/Liquid Measurement conditions: 1.2 17750 1445 3.0) 47/41/35 RFA60QRV16 595x845x300 45(55) 56 R32 10 20 10 15. 1. 19º CWB.8 Coand airflow .1 (15.ATF Series Cooling only EXPERIENCE ELEGANCE IN AIR-CONDITIONING Stabiliser free operation .4 8. Cooling kW Btu/h W W/W A Cooling mm kg m3/min.6) 39/35/29 RFA35QRV16 550x765x285 33(41) 49 R32 10 20 15 12.4~50 1 50Hz 230V (220-240V) Outdoor unit 6. Sound levels are based on the temperature condition in 1above.7/ 6.Improves circulation of cold air Indoor unit Outdoor unit Model name Power supply Power supply intake Cooling capacity Silver particle anti-bacterial filter Kills bacteria and deodorises the air Good sleep off timer . 1.1) 44/41/35 RFA50QRV16 595x845x300 44(54) 50 R32 10 20 10 15. 27º CDB.No extra cost Ton: 1.Avoids excessive cooling and enjoy uninterrupted sleep Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Upto 50°C operating range Cools at high temperature* *Not applicable for 1.4~50 1 50Hz 230V (220-240V) Outdoor unit 5.4 21800 1880 3.4 19.4~46 . outdoor temp. 7/ 6. 1.4 19.4 (17.25 3.5 / 6. height Gas/Liquid IDU Colour: White FTC25QRV16 RC25QRV16 FTC35QRV16 RC35QRV16 FTC50QRV16 RC50QRV16 FTC60QRV16 RC60QRV16 1 50Hz 230V (220-240V) Outdoor unit 2.4~46 1 50Hz 230V (220-240V) Outdoor unit 5. SUPERIOR COOLING Stabiliser free operation . 1.4 19.35 11450 1030 3.0) 47/41/35 RC60QRV16 595x845x300 45(55) 56 R32 10 20 10 12.4~46 Measurement conditions: 1. Cooling capacity is based on: indoor temp. 24° CWB.No extra cost Ton: 0. piping length 5m.7/ 6.Improves circulation of cold air Power chill operation . These are anechoic conversion values.7(8.FTC Series Cooling only EXTRA COMFORT.6) 39/35/29 RC35QRV16 550x765x285 31(39) 51 R32 10 20 15 9.3 FTC50QRV16 White 310x1100x258 13 (18) 18.1 (15.4~46 1 50Hz 230V (220-240V) Outdoor unit 3.5 8500 770 3.0.25 4. outdoor temp.22 17800 1605 3. DAIKIN AIRCONDITIONING INDIA PVT.25 9 FTC60QRV16 White 310x1100x258 13 (18) 20.6) 39/35/29 RC25QRV16 550x765x285 28(36) 51 R32 10 20 15 9.8 Indoor unit Outdoor unit Model name Coand airflow .4~46 1 50Hz 230V (220-240V) Outdoor unit 6. 1.Reduces power consumption Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min. Sound levels are based on the temperature condition in 1.4 21800 1970 3. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max.4 19.6 FTC35QRV16 White 283x800x205 8 (12) 9.5/ 6. 2.35° CDB. length Max.1) 44/41/35 RC50QRV16 595x845x300 39(49) 54 R32 10 20 10 12. 27º CDB.75.Quickly maximises the cooling Econo mode . 20/21 .25 7.4 19.7(8. above.4 FTC25QRV16 White 283x800x205 8 (12) 9.5. LTD. These values are normally somewhat higher during actual operation as a result of ambient conditions. 19º CWB. For the complete feature list please refer pages 30-31. 5. SUPERIOR COOLING Stabiliser free operation .25 3.4 19.6 DTC35QRV16 White 283x800x205 8 (12) 9.6) 39/35/29 RCD25QRV16 550x765x285 28(36) 51 R32 10 20 15 9.4~46 1 50Hz 230V (220-240V) Outdoor unit 3.4 (17. 24° CWB. 19º CWB.3 DTC50QRV16 White 310x1100x258 13 (18) 18.0.5 / 6. height Gas/Liquid IDU Colour: White DTC25QRV16 RCD25QRV16 DTC35QRV16 RCD35QRV16 DTC50QRV16 RCD50QRV16 DTC60QRV16 RCD60QRV16 1 50Hz 230V (220-240V) Outdoor unit 2.7/ 6. 27º CDB.0) 47/41/35 RCD60QRV16 595x845x300 45(55) 56 R32 10 20 10 12.5 8500 770 3. These are anechoic conversion values.DTC Series Cooling only EXTRA COMFORT.7/ 6. above.4~46 1 50Hz 230V (220-240V) Outdoor unit 6. outdoor temp.8 Indoor unit Outdoor unit Model name Econo mode .4 19.4 19. .4~46 Measurement conditions: 1. 35° CDB.Reduces power consumption Power chill operation .25 7.1) 44/41/35 RCD50QRV16 595x845x300 39(49) 54 R32 10 20 10 12.7(8.35 11450 1030 3.4 19. These values are normally somewhat higher during actual operation as a result of ambient conditions.4 DTC25QRV16 White 283x800x205 8 (12) 9.5/ 6.Quickly maximises the cooling Good sleep off timer . dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max. 1.25 4. 2. Cooling capacity is based on: indoor temp.4~46 1 50Hz 230V (220-240V) Outdoor unit 5. piping length 5m. 1. Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min.25 9 DTC60QRV16 White 310x1100x258 13 (18) 20.75.1 (15. 1.Avoids excessive cooling and enjoy uninterrupted sleep For the complete feature list please refer pages 30-31. Sound levels are based on the temperature condition in 1.6) 39/35/29 RCD35QRV16 550x765x285 31(39) 51 R32 10 20 15 9.7(8. length Max.22 17800 1605 3.4 21800 1970 3.No extra cost Ton: 0. Improves circulation of cold air Power chill operation .4~46 Measurement conditions: 1.5 / 6. These values are normally somewhat higher during actual operation as a result of ambient conditions.No extra cost Ton: 0.7(8.1) 44/41/35 RCA50QRV16 595x845x300 39(49) 54 R32 10 20 10 12. 1. SUPERIOR COOLING Stabiliser free operation .0. above. Sound levels are based on the temperature condition in 1.4 (17.7/ 6. virus and mildew For the complete feature list please refer pages 30-31.25 3.4~46 1 50Hz 230V (220-240V) Outdoor unit 3.7(8. 1.99% efficiency against bacteria.4 19. 1.35 11450 1030 3. height Gas/Liquid IDU Colour: White ATC25QRV16 RCA25QRV16 ATC35QRV16 RCA35QRV16 ATC50QRV16 RCA50QRV16 ATC60QRV16 RCA60QRV16 1 50Hz 230V (220-240V) Outdoor unit 2. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max. 35° CDB. Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) *1 Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min.25 9 ATC60QRV16 White 310x1100x258 13 (18) 20. These are anechoic conversion values.4 19. outdoor temp.3 ATC50QRV16 White 310x1100x258 13 (18) 18.25 7.5/ 6. 19º CWB.4~46 1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 1970 3.4 ATC25QRV16 White 283x800x205 8 (12) 9. 2.Quickly maximises the cooling Multi function filter .6) 39/35/29 RCA25QRV16 550x765x285 28(36) 51 R32 10 20 15 9.4~46 1 50Hz 230V (220-240V) Outdoor unit 5.5. length Max. 27º CDB.25 4. 22/23 . DAIKIN AIRCONDITIONING INDIA PVT. 24° CWB.22 17800 1605 3.5 8500 770 3.75.6) 39/35/29 RCA35QRV16 550x765x285 31(39) 51 R32 10 20 15 9. Cooling capacity is based on: indoor temp.1 (15.6 ATC35QRV16 White 283x800x205 8 (12) 9. LTD.0) 47/41/35 RCA60QRV16 595x845x300 45(55) 56 R32 10 20 10 12.4 19.ATC Series Cooling only EXTRA COMFORT.7/ 6.8 Indoor unit Outdoor unit Model name Coand airflow .4 19. piping length 5m. 7/ 6.7(8. IDU Colour: White FTQ35QRV16 RQ35QRV16 FTQ50QRV16 RQ50QRV16 FTQ60QRV16 RQ60QRV16 1 50Hz 230V (220-240V) Outdoor unit 3.4) 45/41/35 RQ50QRV16 595x845x300 36(46) 54 R32 10 20 10 12.8 FTQ50QRV16 White 310x1100x258 13 (18) 18. height Gas/Liquid Measurement conditions: 1.8 Indoor unit Outdoor unit Model name Coand airflow .5 (15.FTQ Series Cooling only EXPERIENCE NIRVANA Stabiliser free operation .4 19.4~46 1 50Hz 230V (220-240V) Outdoor unit 6.4 21800 2100 3.Avoids excessive cooling and enjoy uninterrupted sleep For the complete feature list please refer pages 30-31.05 4. Cooling capacity is based on: indoor temp.Improves circulation of cold air Power chill operation .4 19. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max. 1.Quickly maximises the cooling Good sleep off timer . 24° CWB.9 FTQ35QRV16 White 283x800x205 8 (12) 9.4~46 .05 9.5/ 6. Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min.4 19. 19º CWB. 2.4~46 1 50Hz 230V (220-240V) Outdoor unit 5.0) 47/41/35 RQ60QRV16 595x845x300 45/(55) 56 R32 10 20 10 12.4 (17.6 FTQ60QRV16 White 310x1100x258 13 (18) 20.7/ 6. 27º CDB. 35° CDB. Sound levels are based on the temperature condition in 1. above. piping length 5m.6) 39/35/30 RQ35QRV16 550x765x285 30(38) 51 R32 10 20 15 9.05 7.5. length Max. outdoor temp. These are anechoic conversion values.No extra cost Ton: 1.35 11450 1100 3. 1.2 17750 1705 3. These values are normally somewhat higher during actual operation as a result of ambient conditions. 9 DTQ35QRV16 White 283x800x205 8 (12) 9.6) 39/35/30 RQD35QRV16 550x765x285 30(38) 51 R32 10 20 15 9.6 DTQ60QRV16 White 310x1100x258 13 (18) 20. 24° CWB.35 11450 1100 3.7/ 6. 35° CDB. 2. above. Cooling capacity is based on: indoor temp. outdoor temp.7/ 6.05 9.5 (15.2 17750 1705 3.4 19. 1.4~46 1 50Hz 230V (220-240V) Outdoor unit 5.7(8. 1. length Max. Sound levels are based on the temperature condition in 1.4) 45/41/35 RQD50QRV16 595x845x300 36(46) 54 R32 10 20 10 12. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max. DAIKIN AIRCONDITIONING INDIA PVT.4~46 1 50Hz 230V (220-240V) Outdoor unit 6. height Gas/Liquid IDU Colour: White DTQ35QRV16 RQD35QRV16 DTQ50QRV16 RQD50QRV16 DTQ60QRV16 RQD60QRV16 1 50Hz 230V (220-240V) Outdoor unit 3.4 (17.4~46 Measurement conditions: 1.05 7.Avoids excessive cooling and enjoy uninterrupted sleep For the complete feature list please refer pages 30-31.05 4.DTQ Series Cooling only EXPERIENCE NIRVANA Stabiliser free operation .8 DTQ50QRV16 White 310x1100x258 13 (18) 18. 27º CDB. Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min.No extra cost Ton: 1.0) 47/41/35 RQD60QRV16 595x845x300 45/(55) 56 R32 10 20 10 12. These values are normally somewhat higher during actual operation as a result of ambient conditions.Quickly maximises the cooling Good sleep off timer . 24/25 .4 19.5/ 6. 19º CWB.4 19. These are anechoic conversion values.8 Indoor unit Outdoor unit Model name Econo mode .Reduces power consumption Power chill operation . piping length 5m. LTD.5.4 21800 2100 3. 8 Indoor unit Outdoor unit Model name Econo mode .5 (15. dBA Cooling mm kg dBA Cooling m m m mm DB Rated Charge-less Max.5.9 ATQ35QRV16 White 283x800x205 8 (12) 9. outdoor temp.4 21800 2100 3.Reduces power consumption Power chill operation . 1. 24° CWB.4~46 1 50Hz 230V (220-240V) Outdoor unit 6.05 4. length Max.Quickly maximises the cooling Good sleep off timer .7/ 6. 1. Cooling capacity is based on: indoor temp.6 ATQ60QRV16 White 310x1100x258 13 (18) 20.05 9.5/ 6. 19º CWB.2 17750 1705 3. 35° CDB.35 11450 1100 3. height Gas/Liquid Measurement conditions: 1.6) 39/35/30 RQA35QRV16 550x765x285 30(38) 51 R32 10 20 15 9.No extra cost Ton: 1.4 19. These values are normally somewhat higher during actual operation as a result of ambient conditions.4 19.4 19. IDU Colour: White ATQ35QRV16 RQA35QRV16 ATQ50QRV16 RQA50QRV16 ATQ60QRV16 RQA60QRV16 1 50Hz 230V (220-240V) Outdoor unit 3. These are anechoic conversion values.7(8. Power supply Power supply intake Cooling capacity Power consumption COP Operating current Indoor unit Panel color Dimensions (HxWxD) Weight (Gross) Airflow rate Dry (Wet) Operation sound H/M/L Outdoor unit Dimensions (HxWxD) Weight (Gross) Operation sound (H) Refrigerant Piping length Piping connection Operation limit Cooling kW Btu/h W W/W A Cooling mm kg m3/min.0) 47/41/35 RQA60QRV16 595x845x300 45/(55) 56 R32 10 20 10 12.4 (17. above.Avoids excessive cooling and enjoy uninterrupted sleep For the complete feature list please refer pages 30-31. 27º CDB. 2. Sound levels are based on the temperature condition in 1.7/ 6.4) 45/41/35 RQA50QRV16 595x845x300 36(46) 54 R32 10 20 10 12.8 ATQ50QRV16 White 310x1100x258 13 (18) 18.4~46 .4~46 1 50Hz 230V (220-240V) Outdoor unit 5. piping length 5m.ATQ Series Cooling only EXPERIENCE NIRVANA Stabiliser free operation .05 7. 21 3.01 6. outdoor temp.54 3.5 / 10.094 988 2.99 1.25 5.53 1.4 372 / 355 / 298 / 242 / 225 dB (A) mm kg 41 / 40 / 35 / 29 / 28 288 x 800 x 206 Cooling 9 RYN35CJXV1 Type Cooling Cooling Heating dBA mm kg °CDB °CWB m IDU Colour: White 49 540 x 700 x 250 31 12 5 8.15 3.70 1.5. 50Hz 7. Height Difference Indoor Unit Outdoor Unit FTYN35JXV1 RYN35CJXV1 FTYN50JXV1 RYN50CJXV1 FTYN60JXV1 RYN60CJXV1 5.4 / 15. Heating: indoor temp.38 Cooling Heating Cooling Heating Cooling Heating A A W W W/W W/W 5. DAIKIN AIRCONDITIONING INDIA PVT.42 FTYN35JXV1 Cooling m³/min cfm 10. 7° CDB.26 7. 220-240V.9 / 6.490 6. 35° CDB. 20° CDB.42 FTYN50JXV1 FTYN60JXV1 White 16.5 / 12. For the complete feature list please refer pages 30-31. 1.15 Cooling Heating Kw Kw 3.2 / 13. outdoor temp.Prevents cold draughts Max.8 570 / 536 / 478 / 424 / 375 641 / 614 / 537 / 474 / 418 3 steps.1 / 8.10 4. 1. 24° CWB 2. 27° CDB.1 / 15.635 1.4 / 6.0 / 10.19 6. Piping Length Max. All units are being tested and comply to ISO 5151 (Non-ducted unit).870 1. 6° CWB 3.6 18.Digital display for easy maintenance Fan Speed Sound Levels (T/H/M/L/Q) Dimensions (HxWxD) Machine Weight Outdoor Unit Casing colour Compressor Sound Levels Dimensions (HxWxD) Machine Weight Operation range Hot start . Cooling: indoor temp.88 3.8 Model Name Capacity Programme dry function Reduces humidity Power Supply Running Current Power Consumption COP Indoor Unit Front Panel Colour Airflow rate (T/H/M/L/Q) Self diagnosis . LTD.2 / 17.4 / 11.2 / 13.800 3.28 1 phase.FTYN Series Heat pump FOR ALL SEASONS Saranet filter . 19° CWB.Clean air supply Ton: 1. Turbo and Quiet 44 / 42 / 39 / 36 / 34 48 / 46 / 43 / 40 / 37 310 x 1065 x 224 14 RYN50CJXV1 Light Grey Rotary 52 651 x 855 x 328 47 19°C to 46°C -9°C to 18°C RYN60CJXV1 52 753 x 855 x 328 50 20 15 Measurement conditions: 1. 26/27 . 5-room centralised controller KRC72A Air purifying filter set Air purifying filter set KAF974B42S KAF974B42S Outdoor units No. Time clock and other devices: to be purchased locally. One set includes 5 pieces for 5 units. Both filters are standard accessories. Writing adapter is also required for each indoor unit Cord for wired remote control BRCW901A03 or BRCW901A08 required. One set includes 10 pieces. 1 2 Item FTXR28KVMA FTXR42KVMA FTXR50KVMA 5-room centralised controller*1 KRC72A Wiring adaptor for time clock/remote controller*2 KRP413AB1S (Normal open pulse contact/normal open contact) 3 Air purifying filter set*3 KAF974B42S 4 Air supply filter with frame KAF963A43 5 Remote controller loss prevention chain KKF936A4 Notes: *1. One set includes a 2 m extension hose. *3. Item FTXR28KVMA 1 Central remote controller* 2 Unified on/off controller* 3 Schedule timer* 4 Interface adaptor for D -NET use Note: *A wiring adaptor (KRP928BB2S) is also required for each indoor unit. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 (1) (2) (3) (4) Item Wired remote control (3) Cord for wired remote control 3m BRCW901A08 8m Wiring adapter normal open contact / normal open pulse contact Centralised control board Up to 5 rooms Anti-theft protection for remote control Central remote controller Unified on/off control Schedule timer Interface adapter for DIII-net Online controller External mounting kit for online controller Wifi power cable for online controller Touch LCD wall controller (4) Simple wall controller (4) KNX gateway Wiring adapter supplied by Daikin. Time clock and other devices should be obtained locally.Unit options Indoor units No. FTXR42KVMA DCS302CA51 DCS301BA51 DST301BA51 KRP928BB2S FTXR50KVMA Schedule timer DST301BA51 FTXG series No. Wiring adaptor supplied by DAIKIN. *2. and 2 tieraps RXR28KVMA RXR42KVMA KPW937AA4 KKP937A4 KPMJ942A4 KPMH950A4L KPMH942A42 KPMH942A402 RXR50KVMA Drain plug Humidity hose L cuff KKP937A4 KPMH950A4L Central remote controller Unified on/off controller DCS302CA51 DCS301BA51 Humidity hose extension set System configurations No. Can only be used in combination with online controller KKRP01A FTXG25J FTXG35J BRC944 BRCW901A03 KRP413A1S (1) KRC72 (2) KKF910A4 DCS302C51 DCS301B51 DST301B51 KRP928A2S KKR901A KKRPMO1A KKRPW01A KBRC01A KBRC501A KLIC-DD FTXG50J . A wiring adaptor (KRP413AB1S) is also required for each indoor unit. *2. A set of a frameless titanium apatite photocatalytic air-purifying filter and a frameless deodorising filter for the streamer discharge unit. *3. Item 1 Air direction adjustment grille 2 Drain plug*1 3 Humidity hose extension joint*2 4 Humidity hose L cuff*2 5 Humidity hose (10 m) 6 Humidity hose extension set*3 Notes: *1. 1 joint. 28/29 DAIKIN AIRCONDITIONING INDIA PVT. 1 1 2 3 2 4 3 3 4 Note: 4 Note: Note: FTXS25/35 Wiring for time clock/remote controller (normal open pluse contact/normal Item 5-roomadaptor centralised controller open 5-room centralised controller Wiringcontact) adaptor for time clock/remote controller (normal open pluse contact/normal Titanium apatitefor photocatalytic air purifying filter(normal open pluse contact/normal Wiring adaptor time clock/remote controller open contact) Remote controller loss prevention chain and open contact) Titanium apatite photocatalytic airfor purifying filterholder Titanium apatite photocatalytic airfor filterholder controller loss prevention chain and *1. LTD. It should replacedlocally. Notes: *1. *2. The A wiring adaptor (KRP413AB1S) isshould also required for each indoor unit. Item 2 Unified No. Outdoor units No. every 3 years. Remote controller lossother prevention chainbe and holder locally. The The filter time clock and other devices should bebe obtained *3. Item 2 No. *3. *2. Notes: *1. KP. 28/29 DAIKIN AIRCONDITIONING INDIA PVT. The filter is a standard accessory. LTD. A wiring adaptor (KRP928BB2S) is also required for each indoor unit. *3. LTD. Item 1 Central on/off remotecontroller controller 3 Schedule timercontroller 1 Central on/off remote controller 2 Unified 4 Interface adaptor for DIII-NET use 2 Unified on/off 3 Schedule timercontroller 3 Schedule timer 4 DIII-NET use is also required for each indoor unit. Item units Outdoor Outdoor unitsadjustment grille 1 Air direction No.Interface A wiringadaptor adaptorfor (KRP928BB2S) 4 Interface adaptor for DIII-NET use Notes: *1. Item Indoor units Indoor unitscentralised controller 1 5-room No.Remote A wiring adaptor (KRP413AB1S) ispurifying also required for each indoor unit. A wiring adaptor (KRP928BB2S) is also required for each indoor unit. *1 *1 *1 *1 *1 *1 *1 FTXS50/60/71 KRC72 FTXS50/60/71 FTXS25/35 FTXS25/35 KRP413AB1S KRC72 FTXS50/60/71 KRC72 KRP413AB1S KAF970A46 KRP413AB1S KAF952B42 KAF970A46 KKF917A4 KAF952B42 KAF970A46 KKF917A4 KAF952B42 KKF917A4 RXS25/35 KPW945A4 RXS25/35 KKP937A4 RXS25/35 KPW945A4 KPW945A4 KKP937A4 KKP937A4 RXS50/60/71 KPW945A4 RXS50/60/71 KKP937A4 RXS50/60/71 KPW945A4 (For RXS71KPW945A4 KKP937A4 KKP945A4) KKP937A4 (For RXS71(For RXS71KKP945A4) KKP945A4) FTXS25/35E FTXS50/60/71F FTXS25/35E DCS302CA61 FTXS50/60/71F DCS301BA61FTXS50/60/71F FTXS25/35E DCS302CA61 DST301BA61 DCS302CA61 DCS301BA61 KRP928BB2S DCS301BA61 DST301BA61 DST301BA61 KRP928BB2S KRP928BB2S Optional Wi-Fi adaptor kit code for KM. is a standard accessory. 28/29 . time clock and devicesfor obtained *1. The A wiring (KRP413AB1S) required for each indoor unit. Item 2 No. The time adaptor clock and other devicesisshould bebe obtained locally.Indoor units No. filter is a standard accessory. FTKH Series-BRP072A42 Optional Parts Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Optional Parts Optional Parts Titanium apatite photo catalytic air purifying filter Ag-ion (withphoto frame)catalytic air purifying filter Titaniumfilter apatite Multi-function filter Titaniumfilter apatite photo Ag-ion (with frame)catalytic air purifying filter Ag-ion filter (with Multi-function filterframe) Multi-function filter Optional Parts Optional Parts Titanium Optionalapatite Parts photo catalytic air purifying filter Ag-ion (withphoto frame)catalytic air purifying filter Titaniumfilter apatite Multi-function filter Titaniumfilter apatite photo Ag-ion (with frame)catalytic air purifying filter Ag-ion filter (with Multi-function filterframe) Multi-function filter 5 Star FTF35QRV16 FTF50QRV16 5 Star RF35QRV16 RF50QRV16 5 Star FTF35QRV16 FTF50QRV16 DTF35QRV16 DTF50QRV16 FTF35QRV16 FTF50QRV16 RF35QRV16 RF50QRV16 RFD35QRV16 RFD50QRV16 RF35QRV16 RF50QRV16 DTF35QRV16 DTF50QRV16 Included with the unit DTF50QRV16 in accessories bag DTF35QRV16 RFD35QRV16 RFD50QRV16 RFD35QRV16 Included with the unit RFD50QRV16 in accessories bag Included with the unit in accessories bag 5 Star ATF35QRV16 ATF50QRV16 5 Star RFA35QRV16 RFA50QRV16 5 Star ATF35QRV16 ATF50QRV16 ATF35QRV16 ATF50QRV16 RFA35QRV16 RFA50QRV16 Included with the unit in accessories RFA35QRV16 RFA50QRV16 bag Included with the unit in KAF001A500 accessories bag Included with the unit in KAF001A500 accessories bag KAF001A500 FTF60QRV16 RF60QRV16 FTF60QRV16 DTF60QRV16 FTF60QRV16 RF60QRV16 RFD60QRV16 RF60QRV16 DTF60QRV16 DTF60QRV16 RFD60QRV16 RFD60QRV16 FTC25QRV16 RC25QRV16 FTC25QRV16 DTC25QRV16 FTC25QRV16 RC25QRV16 RCD25QRV16 RC25QRV16 DTC25QRV16 DTC25QRV16 RCD25QRV16 RCD25QRV16 ATF60QRV16 RFA60QRV16 ATF60QRV16 ATF60QRV16 RFA60QRV16 RFA60QRV16 ATC25QRV16 RCA25QRV16 ATC25QRV16 ATC25QRV16 RCA25QRV16 RCA25QRV16 Remote Controller Loss Prevention with Remote Controller the Chain Remote Controller Loss Prevention with Loss Prevention with the Chain KKF917A4 the Chain KKF917A4 KKF917A4 5-room Centralised Controller 5-room Centralised 5-room Centralised Controller KRC72 Controller KRC72 KRC72 Titanium Apatite Photocatalytic Air-Purifying FilterPhotocatalytic Titanium Apatite Titanium Apatite Air-Purifying FilterPhotocatalytic KAF970A46 Air-Purifying Filter KAF970A46 KAF970A46 Titanium Apatite Photocatalytic AirPurifying Filter Titanium Apatite Photocatalytic AirTitanium Apatite Photocatalytic AirPurifying Filter KAF952B42 Purifying Filter KAF952B42 KAF952B42 Air Direction Adjustment Grille Drain Plug Air Direction Adjustment Grille KPW945A4 Air Direction Adjustment Grille KPW945A4 KPW945A4 Drain Plug KKP937A4 Drain Plug KKP937A4 KKP937A4 Central Remote Controller Unified On/Off Controller Schedule Timer Central Remote Controller DCS302CA61 Central Remote Controller DCS302CA61 DCS302CA61 Unified On/Off Controller DCS301BA61 Unified On/Off Controller DCS301BA61 DCS301BA61 Schedule Timer DST301BA61 Schedule Timer DST301BA61 DST301BA61 3 Star FTC35QRV16 3 Star FTC50QRV16 FTC60QRV16 FTQ35QRV16 RC35QRV16 RC50QRV16 RC60QRV16 RQ35QRV16 3 Star FTC35QRV16 FTC50QRV16 FTC60QRV16 FTQ35QRV16 DTC35QRV16 DTC50QRV16 DTC60QRV16 DTQ35QRV16 FTC35QRV16 FTC50QRV16 FTC60QRV16 FTQ35QRV16 RC35QRV16 RC50QRV16 RC60QRV16 RQ35QRV16 RCD35QRV16 RCD50QRV16 RCD60QRV16 RQD35QRV16 RC35QRV16 RC50QRV16 RC60QRV16 RQ35QRV16 DTC35QRV16 DTC50QRV16 DTC60QRV16 DTQ35QRV16 KAF970A45 DTC35QRV16 DTC50QRV16 DTC60QRV16 DTQ35QRV16 RCD35QRV16 RCD50QRV16 RCD60QRV16 RQD35QRV16 RCD35QRV16KAF057A41 RCD50QRV16 RCD60QRV16 RQD35QRV16 KAF970A45 KAF001A500 KAF970A45 KAF057A41 KAF057A41 KAF001A500 KAF001A500 3 Star ATC35QRV16 3 Star ATC50QRV16 ATC60QRV16 ATQ35QRV16 RCA35QRV16 3 Star RCA50QRV16 RCA60QRV16 RQA35QRV16 ATC35QRV16 ATC50QRV16 ATC60QRV16 ATQ35QRV16 ATC35QRV16 ATC50QRV16 ATC60QRV16 ATQ35QRV16 RCA35QRV16KAF970A45 RCA50QRV16 RCA60QRV16 RQA35QRV16 KAF057A41 RCA35QRV16KAF970A45 RCA50QRV16 RCA60QRV16 RQA35QRV16 Included with the unit in accessories bag KAF970A45 KAF057A41 KAF057A41 Included with the unit in accessories bag Included with the unit in accessories bag 2 Star FTQ50QRV16 2 Star RQ50QRV16 2 Star FTQ50QRV16 DTQ50QRV16 FTQ50QRV16 RQ50QRV16 RQD50QRV16 RQ50QRV16 DTQ50QRV16 DTQ50QRV16 RQD50QRV16 RQD50QRV16 FTQ60QRV16 RQ60QRV16 FTQ60QRV16 DTQ60QRV16 FTQ60QRV16 RQ60QRV16 RQD60QRV16 RQ60QRV16 DTQ60QRV16 DTQ60QRV16 RQD60QRV16 RQD60QRV16 2 Star ATQ50QRV16 2 Star RQA50QRV16 2 Star ATQ50QRV16 ATQ50QRV16 RQA50QRV16 RQA50QRV16 ATQ60QRV16 RQA60QRV16 ATQ60QRV16 ATQ60QRV16 RQA60QRV16 RQA60QRV16 DAIKIN AIRCONDITIONING INDIA PVT. *2. approximately every 3 years. ItemSystem Control Control System 1 Central remote controller No. 1 1 2 2 Drain plug adjustment grille Item Air direction Air direction Drain plug adjustment grille Drain plug Control System No. It should be replaced approximately every 3 years. It also should replaced approximately *1. Feature list Technology Humidity control Comfortable airflow Comfort control Lifestyle convenience Cleanliness Timers Worry free Control Function Swing compressor and reluctance DC Motor Rotary compressor PAM control Humidifying operation Drying operation Dry cooling operation Moisturising operation Cooling breeze operation Comfortable mode Power-airflow flap Power-airflow dual flaps Wide-angle louvres Vertical auto swing Horizontal auto swing 3-D airflow Comfort sleep operation Hot start Coanda airflow Indoor unit quiet operation Outdoor unit quiet operation Intelligent eye Automatic operation (Heating & Cooling) Programme dry function Auto fan speed Temperature and humidity level information display Econo mode Home leave operation Inverter powerful operation New powerful operation (non-inverter) Power chill operation Indoor unit on/off switch Child lock Multi-colored indicator Monitor brightness setting Fan only Filter cleaning indicator (on R/C) Mould shock operation Home leave ventilation Streamer discharge air purifier Mould-proof operation Mould proof stick Smell proof operation Titanium apatite photocatalytic air purifying filter Air purifying filter Air intake filter Silver particle anti-bacterial filter Saranet filter Air purifying filter with photocatalytic deodersing function Fresh air supply ventilation Multi-function filter Wipe-clean flat panel 24-Hour on/off timer Count up-down on/off timer Weekly timer Night set mode Good sleep off timer New good sleep off timer Auto restart (after power failure) Stabiliser free operation Self-diagnosis PE anti-corrosion treatment of outdoor heat exchanger Remote control with backlight Luminescent remote control buttons Indoor temperature display on remote control Remote control LCD back light off Smartphone connection FTXR 28/42/50 FTXG 25/35/50 FTXS 25/35 FTXS 50/60/71 FTKM 25/35 FTKM 50/60/71 DTKM 25/35 DTKM 50/60 ATKM 25/35 ATKM 50/60 FTKP 25/35 FTKP 50/60/71 DTKP 25/35 DTKP 50/60/71 ATKP 25/35 o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Option o Option o o o o o o o o o Option Option Option Option Option o o Option Option Option Option o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Option o o Option o o Option o o Option o o Option o o Option o o Option o o Option o o Option o o Option o o Option o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o . 30/31 o o . LTD.Technology Humidity control Comfortable airflow Comfort control Lifestyle convenience Cleanliness Timers Worry free Control Function ATKP 50/60/71 o Swing compressor and reluctance DC Motor Rotary compressor PAM control o Humidifying operation Drying operation Dry cooling operation Moisturising operation Cooling breeze operation Comfortable mode Power-airflow flap o Power-airflow dual flaps Wide-angle louvres o Vertical auto swing o Horizontal auto swing o 3-D airflow o Comfort sleep operation Hot start Coanda airflow o o Indoor unit quiet operation o Outdoor unit quiet operation Intelligent eye Automatic operation (Heating & Cooling) Programme dry function o Auto fan speed o Temperature and humidity level information display Econo mode o Home leave operation Inverter powerful operation New powerful operation (non-inverter) Power chill operation o Indoor unit on/off switch o Child lock o Multi-colored indicator Monitor brightness setting Fan only o Filter cleaning indicator (on R/C) Mould shock operation Home leave ventilation Streamer discharge air purifier Mould-proof operation Mould proof stick Smell proof operation o Titanium apatite photocatalytic air purifying filter Option Air purifying filter Air intake filter Silver particle anti-bacterial filter o Saranet filter Air purifying filter with photocatalytic deodersing function Fresh air supply ventilation Multi-function filter Wipe-clean flat panel o 24-Hour on/off timer o Count up-down on/off timer Weekly timer Night set mode Good sleep off timer New good sleep off timer o Auto restart (after power failure) o Stabiliser free operation o Self-diagnosis o PE anti-corrosion treatment of outdoor heat exchanger o o Remote control with backlight Luminescent remote control buttons Indoor temperature display on remote control o Remote control LCD back light off o Smartphone connection Option FTKH 35 FTKH 50/60 FTF35 FTF50/60 DTF35 DTF50/60 ATF35 ATF50/60 FTC 25/35 FTC50/60 DTC 25/35 DTC50/60 ATC 25/35 ATC50/60 FTQ35 FTQ50/60 DTQ35 DTQ50/60 ATQ35 ATQ50/60 FTYN o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Option o o Option o o o o o o o o o o Option o Option o Option o Option o Option o Option o Option o Option o Option o Option o Option o Option o Option o Option Option Option Option Option Option Option o o Option Option Option Option Option Option Option Option Option Option Option Option o o Option o o Option o o Option o o Option o o Option o o Option o o Option o Option o Option o Option o o o o o Option o Option o Option o Option o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Option Option DAIKIN AIRCONDITIONING INDIA PVT. No wonder Daikin is recognised as an expert in air-conditioning. Unmatched after-sales support Five-year warranty on compressors Wise investment – Low running cost Experienced dealers Environment friendly Daikin takes pride in providing its customers with efficient after sales support. including readily available spare parts warehoused in India. Daikin systems offer superior build quality and energy efficiency. Daikin continues to work towards a sustainable future. When you buy a Daikin airconditioning system you need to look beyond the initial purchase price. Reliability. That’s probably top of your list when buying an airconditioning system for your home or business. Daikin is committed to the air-conditioning market and has a manufacturing facility located in Rajasthan. It pays to consider ongoing running costs in conjunction with the potential life of the product. Daikin Airconditioning India Pvt. As specialists.delivering optimal performance . That’s how confident Daikin is about the quality and reliability of its product. Daikin gives you peace of mind and reassurance with their five-year warranty on compressors of split airconditioners. Daikin air-conditioning equipment can be found in homes. These systems provide a more comfortable environment and are more energy efficient when compared to noninverter systems. Designed to provide effective and quiet air-conditioning.Ten Reasons to Buy Daikin Air-conditioning specialist Pioneer in air-conditioners The Daikin edge with in-house manufacturing High energy efficiency Comprehensive range and quiet operation Daikin focuses on air-conditioning solutions and control systems. Daikin has a comprehensive range of products in both domestic and commercial segments. and has received Environmental Management System certification to ISO14001.from the time a project begins till the moment of absolute comfort. ducted and other systems. Daikin is the only company in the world dedicated to manufacturing both air-conditioning systems and refrigerants. As one of the industry’s more trusted names. Ltd. Terms & Conditions Apply . Together this means the best air-conditioning solution for your individual needs. is dedicated to preserving and protecting the environment through the production of energy efficient products. Each element has been designed to work flawlessly with the next . Daikin distributes its products through experienced dealers. offices. it’s all we do. Daikin can customise a solution to meet every requirement. Daikin has been providing air-conditioning solutions for over 15 years in India. Daikin’s continuous drive for improved efficiency has seen its advanced inverter technology being applied to split. hotels and shops. This ensures that you receive a top quality product with expert support. . the design and specifications are subject to change without prior notice. Gurgaon 122002 Haryana.com Visit us at www.daikinindia. 1800-22-9300 cs@daikinindia. Sales revenue includes revenue through sales of all Daikin Airconditioning Systems.in) Bengaluru Lucknow Tel: 0522-2787307/340 Service toll free 1800-102-9300. India Tel: 0124-4555444. ‘Products mentioned in this brochure comply with RoHS regulations as per E-waste (Management & Handling) Rules. Disclaimer As a continuing policy of product innovation of Daikin.com /company/daikin-airconditioning-india-pvt.com or contact our customer care centre at 1800 102 9300 / 1800 22 9300 concept and design at Tel: 079-26583013-14 Delhi NCR Tel: 0124-4555444 DAIPL-2014/14-RA20-1A Ahmedabad . DLF Cyber City DLF Phase III. actual products might differ from the ones shown.com Sales & Service Offices Tel: 080-25590452-54 Chandigarh Tel: 0172-5089862-64 Chennai Tel: 044-24314210-15 Hyderabad Tel: 040-39134289 Mumbai Tel: 022-30926666 Jaipur Tel: 0141-2223215 Pune Tel: 020-25560300 Kolkata Tel: 033-22894259/60 (
[email protected] Address DAIKIN AIRCONDITIONING INDIA PVT. 1 position based on internal assessment of total sales revenue for 2012-13.com /daikinindia /daikinindia daikinindiablog. 12th Floor.-ltd. Fax: 0124-4555333 Email ID:
[email protected]. World’s no. The visuals of the products in the brochure are representative only.’ For more details kindly visit our website www. Building No 9 Tower A. LTD. 2011and should not be mixed with general household waste at the end of their useful life.