Daikin Engineering Data Split (Cooling Only) J-Series (2015)

March 26, 2018 | Author: Adam Chan | Category: Air Conditioning, Mechanical Fan, Hvac, Decibel, Heat Exchanger


Comments



Description

EDHK011026- Cooling Only J-Series EDHK011026 Split-System Room Air Conditioners J-Series Cooling Only 1. 2. 3. 4. FTN50JV18 FTN60JV18 RN50JV1 RN60JV1 Power Supply ..........................................................................................2 Functions.................................................................................................3 Specifications ..........................................................................................4 Dimensions .............................................................................................5 4.1 Indoor Unit................................................................................................5 4.2 Outdoor Unit .............................................................................................6 5. Wiring Diagrams......................................................................................7 5.1 Indoor Unit................................................................................................7 5.2 Outdoor Unit .............................................................................................8 6. Piping Diagrams......................................................................................9 6.1 Indoor Unit................................................................................................9 6.2 Outdoor Unit .............................................................................................9 7. Capacity Tables ....................................................................................10 7.1 Cooling Only...........................................................................................10 7.2 Capacity Correction Factor by the Length of Refrigerant Piping (Reference) ............................................................................................11 8. Operation Limit......................................................................................12 9. Sound Level ..........................................................................................13 9.1 Measuring Location ................................................................................13 9.2 Octave Band Level .................................................................................14 10.Electric Characteristics..........................................................................15 11.Installation Manual ................................................................................16 11.1 Safety Precautions .................................................................................16 11.2 50 Class .................................................................................................17 11.3 60 Class .................................................................................................26 12.Operation Manual..................................................................................35 13.Optional Accessories ............................................................................56 13.1 Option List ..............................................................................................56 13.2 Installation Manual .................................................................................57 Room Air Conditioners J-Series 1 220 . Outdoor Unit Room Air Conditioners J-Series . 50 Hz Power Supply Intake .240 V.Power Supply EDHK011026 1. Power Supply Note: 2 Indoor Units Outdoor Units FTN50JV18 RN50JV1 FTN60JV18 RN60JV1 Power Supply 1 φ.230 . LED) Display { { Wiring Error Check Function — 3-D Airflow { COMFORT AIRFLOW Operation — Anti-Corrosion Treatment of Outdoor Heat Exchanger { — Comfort Control Auto Fan Speed Operation — Category FTN50/60JV18 RN50/60JV1 Category FTN50/60JV18 RN50/60JV1 2.EDHK011026 Functions Basic Function Compressor Comfortable Airflow Functions Inverter (with Inverter Power Control) Lifestyle Convenience Health & Clean Functions Air-Purifying Filter — Photocatalytic Deodorizing Filter — Operation Limit for Cooling (°CDB) 19. Functions { Flexibility Indoor Unit Quiet Operation — Multi-Split / Split Type Compatible Indoor Unit NIGHT QUIET Mode (Automatic) — Flexible Voltage Correspondence Outdoor Unit Quiet Operation (Manual) — Chargeless INTELLIGENT EYE Operation — Either Side Drain (Right or Left) { Quick Warming Function (Preheating Operation) — Power Selection — Hot-Start Function — Automatic Defrosting — Automatic Operation — Program Dry Operation { Fan Only { New POWERFUL Operation (Non-Inverter) { Inverter POWERFUL Operation — Priority-Room Setting — COOL/HEAT Mode Lock — HOME LEAVE Operation — ECONO Operation — Indoor Unit ON/OFF Button { Signal Receiving Sign { Temperature Display — Remote Control 5-Rooms Centralized Controller (Option) Remote Controller — 10 m — Remote Control Adaptor (Normal Open-Pulse Contact) (Option) — Remote Control Adaptor (Normal Open Contact) (Option) — DIII-NET Compatible (Adaptor) (Option) — Wireless { Wired (Option) — Note: { : Holding Functions — : No Functions Room Air Conditioners J-Series 3 .4 ~46 Operation Limit for Heating (°CWB) — Air-Purifying Filter with Photocatalytic Deodorizing Function { PAM Control — Titanium Apatite Photocatalytic Air-Purifying Filter — Oval Scroll Compressor — Air Filter (Prefilter) { Swing Compressor — Wipe-Clean Flat Panel { Rotary Compressor { Washable Grille — Reluctance DC Motor — MOLD PROOF Operation — Power-Airflow Flap — Heating Dry Operation — Power-Airflow Dual Flaps { Good-Sleep Cooling Operation — 24-Hour ON/OFF TIMER { Power-Airflow Diffuser — NIGHT SET Mode { Wide-Angle Louvers { Auto-Restart (after Power Failure) { Vertical Auto-Swing (Up and Down) { Horizontal Auto-Swing (Right and Left) Timer Worry Free “Reliability & Durability” Self-Diagnosis (Digital. 300 FV50S 0.4 φ 15. Interunit Height Difference Chargeless Amount of Additional Charge of Refrigerant Indoor Units Front Panel Color H Airflow Rate M L Type Fan Motor Output Speed Air Direction Control Air Filter Running Current Power Consumption Power Factor Temperature Control Dimensions (H × W × D) Packaged Dimensions (H × W × D) Weight Gross Weight Operation H/M/L Sound Outdoor Units Casing Color Type Compressor Model Motor Output Type Refrigerant Oil Charge Type Refrigerant Charge Airflow Rate H Type Fan Motor Output Running Current (Rated) Power Consumption (Rated) Power Factor Starting Current Dimensions (H × W × D) Packaged Dimensions (H × W × D) Weight Gross Weight Operation H Sound Drawing No.0 2.7 φ 18.050 × 238 337 × 1.1 1.5 m kcal/h = kW × 860 Btu/h = kW × 3412 cfm = m³/min × 35. Left.5 (653) 15.760 3.3 18. Horizontal. Cooling Piping Length Conversion Formulae Indoor .0 1. Downward Removable / Washable / Mildew Proof 0.5 (618) 14. Auto Right. Downward Removable / Washable / Mildew Proof 0. 220 V Models Indoor Units Outdoor Units Capacity (Rated) Moisture Removal Running Current (Rated) Power Consumption (Rated) Power Factor COP (Rated) Liquid Piping Connections Gas Drain Heat Insulation Max.167 98 54 770 × 900 × 320 900 × 925 × 390 63 76 m³/min (cfm) W Steps A W % W L kg m³/min cfm W A W % A mm mm kg kg dBA 50 52 C:3D067874B C:3D067875A „ The data are based on the conditions shown in the table below.3 Room Air Conditioners J-Series .2 2.2 43 98 Microcomputer Control 290 × 1.90 R-410A 2.872 Propeller 65 10.2 43 98 Microcomputer Control 290 × 1.52 R-410A 1.4 φ 12.9 (420) Cross Flow Fan 43 5 Steps.7 (519) 11.700 FV50S 0.147 × 366 12 17 dBA 45 / 40 / 35 47 / 41 / 36 RN50JV1 Ivory White Hermetically Sealed Rotary Type RN196VHSMT 1.147 × 366 12 17 FTN60JV18 White 18.7 22.560 2.1 (533) 11.210 98 3.9 φ 18.840 Propeller 50 7.5 1.9 7. Horizontal.0 Both Liquid and Gas Pipes 30 20 10 20 20 mm mm kg kg FTN50JV18 White 17.9 (420) Cross Flow Fan 43 5 Steps. Auto Right.090 4.597 98 33 735 × 825 × 300 784 × 960 × 390 48 55 RN60JV1 Ivory White Hermetically Sealed Rotary Type PN25VAAMT 1.23 φ 6. 27°CDB / 19°CWB Outdoor .0 53. Note: 4 FTN50JV18 RN50JV1 5. Interunit Piping Length Max. 35°CDB / 24°CWB 7.050 × 238 337 × 1.860 5.Specifications EDHK011026 3.6 52.9 10. Left.03 φ 6.0 Both Liquid and Gas Pipes 30 20 10 kW Btu/h kcal/h L/h A W % W/W mm mm mm m m m g/m FTN60JV18 RN60JV1 6.3 1.640 98 3. Specifications 50 Hz. 5 52 163 HORIZONTAL BLADE (AUTOMATIC) COOLING 10˚ 1050 14.4 CuT OUTSIDE THE UNIT : (THE LENGTH OF PIPE OUTSIDE ABOUT 530) THE UNIT : ABOUT 480) GAS PIPE 15. 18.50 ( ) OPERATION LAMP DRAIN HOSE FOR VP13 (CONNECTING PART I.50 OPERATION LAMP SIGNAL RECEIVER INDOOR UNIT ON/OFF SWITCH ) TERMINAL BLOCK WITH EARTH TERMINAL (INSIDE) ROOM TEMP.9 CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT : ABOUT 430) TIMER LAMP FRONT GRILLE FIXING SCREWS (INSIDE) 58 BLADE ANGLES DRY 5˚ 40˚ 10˚ 40˚ 35˚ 5˚ 35˚ FAN VERTICAL BLADE (AUTOMATIC) WIRELESS REMOTE CONTROLLER 5˚ 50˚ 5˚ (ARC433A26) 55˚ Room Air Conditioners J-Series 52. Dimensions 4.0.0) (THE HOSE LENGTH OF LIQUID PIPE 6.0. D.D. D.7 CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 430) TIMER LAMP HOME LEAVE LAMP FRONT GRILLE FIXING SCREWS (INSIDE) BLADE ANGLES 10˚ 5˚ 10˚ 40˚ 35˚ FAN 60 VERTICAL BLADE(MANUAL) 5˚ 50˚ 5˚ 55˚ 99.50 (SPACE FOR MAINTENANCE) REQUIRED SPACE INCLUDING INSTALLATION PLATE 240 238 30 REAR LEFT MIN.EDHK011026 Dimensions 4.4 CuT OUTSIDE THE UNIT: (THE LENGTH OF PIPE OUTSIDE ABOUT 530) THE UNIT: ABOUT 480) GAS PIPE 12.0) (THE HOSE LENGTH OF LIQUID PIPE 6.5 290 FLAPS MIN.O.14. THERMISTOR (INSIDE) MIN.5 5˚ 35˚ 40˚ WIRELESS REMOTE 893.30 (SPACE FOR PERFORMANCE) AIR FLOW (INDOOR) (FOR PERFORMANCE AND MAINTENANCE) THE MARK (→) SHOWS PIPING DIRECTION 50˚ 3D065874B 55˚ AIR FLOW (INDOOR) (FOR PERFORMANCE AND MAINTENANCE) REAR RIGHT (SPACE FOR MAINTENANCE) MIN. 14.5 52 REAR LEFT MIN.50 (SPACE FOR MAINTENANCE) REQUIRED SPACE MODEL NAME PLATE 290 ( INCLUDING INSTALLATION PLATE 240 238 30 1050 55˚ ˚ 50 60 99. O.5 WALL HOLE φ80 HOLE WALL HOLE FOR EMBEDDED PIPING φ80 HOLE STANDARD LOCATIONS OF WALL HOLES CONTROLLER (ARC433A26) 52.5 SIGNAL TRANSMITTER 58 TERMINAL BLOCK WITH EARTH TERMINAL (INSIDE) 52 FLAPS MODEL NAME PLATE 290 SIGNAL RECEIVER INDOOR UNIT ON/OFF SWITCH ROOM TEMP.5 290 18 1050 14.5 893.5 SIGNAL TRANSMITTER 18 155.1 Indoor Unit FTN50JV18 REAR 1050 RIGHT (SPACE FOR MAINTENANCE) MIN.D. THERMISTOR (INSIDE) DRAIN HOSE FOR VP13 (CONNECTING PART I.30 THE MARK (→) SHOWS PIPING DIRECTION (SPACE FOR PERFORMANCE) FTN60JV18 WALL HOLE φ80 HOLE WALL HOLE FOR EMBEDDED PIPING φ80 HOLE STANDARD LOCATIONS OF WALL HOLES 3D059038E 5 .5 DRY 52 163 HORIZONTAL BLADE (AUTOMATIC) COOLING 155.18. 7CuT) SERVICE PORT 3D065853D RN60JV1 30 48 55 320 350 (345~355) 30 Hole for anchor bolt 4 .D.M12 40 140 96 140 620 30 900 3 2 1 6 6 5 770 5 4 28 89 89 19 71 6 376 223 53 95 80 145 52 13 67 16 16 7 6 5 4 3 4 2 1 NOTE) 1. 58 70 102 117 45 54 95 84 55 19 142 7 352 329 143 54 95 60 55 4 191 Drain pipe connection Control wiring intake Power supply wiring intake Refrigerant piping intake Grounding terminal Liquid pipe connection Gas pipe connection Parts name Outside Diameter φ 26 3points φ 27 knock hole φ 34 knock hole M5(in switch box) φ 6.4CuT) 18 160 30 GAS STOP VALVE (φ12.2 EDHK011026 Outdoor Unit DRAIN OUTLET (I. NO.9 Flare Remarks 3D055315H Room Air Conditioners J-Series .Dimensions 4.φ15.ATTACHED PIPING MAY NOT BE ATTACHED WITH A MODEL.4 Flare φ 15.9 HOSE FOR CONNECTION) MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE =LESS THAN 1200 100 RN50JV1 78 825 50 350 50 50 350 100 300 36 330 25 350 10 580 2 350 124 100 325 4-HOLES FOR ANCHOR BOLTS (M8 OR M10) NAME PLATE WIRING INLET EARTH TERMINAL IN SWITCH BOX 89 64 735 BRAND NAME LABEL 155 LIQUID STOP VALVE (φ6. V2 X1M : FRAME GROUND : FUSE : HARNESS : PILOT LAMP : FAN MOTOR : SWING MOTOR : MAGNETIC RELAY : PRINTED CIRCUIT BOARD : THERMISTOR : CONNECTOR : OPERATION SWITCH : SURGE ARRESTER : VARISTOR : TERMINAL STRIP : PROTECTIVE EARTH 3D058895D 7 .15A V1 H2 MR2 H3 S38 SA1 V2 CAUTION NOTE THAT OPERATION WILL RESTART AUTOMATICALLY IF THE MAIN POWER SUPPLY IS TURNED OFF AND THEN BACK ON AGAIN.1 Indoor Unit FTN50/60JV18 FIELD WIRING.EDHK011026 Wiring Diagrams 5. PCB3 S27 S26 PCB1 H1 X1M 1 RED 1 2 WHT 2 3 t˚ BLK 3 R1T GRN/ YLW ~ RECTIFIER ~ Fu 3. Wiring Diagrams 5. H2P M1F M1S. R2T S1~S38 S1W SA1 V1. FG PCB4 S37 7 S21 OUTDOOR S1 RED LED1 LED2 H1P BLU BRN ORG WHT H2P 1 SIGNAL RECEIVER WIRELESS REMOTE CONTROLLER t˚ S29 S1W Room Air Conditioners J-Series 1 S6 5 1 S8 M1F 6 BRN RED ORG YLW PNK BLU PCB2 S32 RED ORG YLW PNK BLU S28 M INDOOR R2T M M1S M M2S FG Fu H1~H3 H1P. M2S MR2 PCB1~PCB4 R1T. C12R : RUNNING CAPACITOR M1F : FAN MOTOR S1T : THERMOSTAT F1S : SURGE ARRESTER M1C : COMPRESSOR MOTOR L : LIVE F1U : FUSE X11A : CONNECTOR N : NEUTRAL K1M : MAGNETIC CONTACTOR X1M.2 EDHK011026 Outdoor Unit RN50JV1 FIELD WIRING indoor TO INDOOR UNIT X1M outdoor 1 1 1 RED 2 BLU RED 5 BLK RED BLK V1R M1C S1T 1 A2 K1M t° 4 2 H C 4 3 2 X2M GRN/YLW R BLK A1 F1U WHT POWER SUPPLY ~ 50Hz 220V-240V RED L RED N N 6 M 1~ S A1 A2 BLK 3. C12R : RUNNING CAPACITOR M1F : FAN MOTOR S1T : THERMOSTAT F1S : SURGE ARRESTER M1C : COMPRESSOR MOTOR L : LIVE F1U : FUSE X11A : CONNECTOR N : NEUTRAL K1M : MAGNETIC CONTACTOR X1M.Wiring Diagrams 5. X2M : TERMINAL STRIP V1R : RECTIFIER C12R BLK ORG M 1~ RED WHT M1F X11A : PROTECTIVE EARTH 3D066807B 8 Room Air Conditioners J-Series .15A L L RED C YLW C11R BLK 3 4 WHT RED 3 GRN/YLW 3 2 2 B1 B2 F1S 3 1 WHT 1 C12R BLK C11R. X2M : TERMINAL STRIP V1R : RECTIFIER 6 BLK L ORG H 3 RED 4 BLK M 1~ ORG RED WHT M1F X11A : PROTECTIVE EARTH 3D066609A RN60JV1 FIELD WIRING indoor TO INDOOR UNIT X1M outdoor 1 1 1 2 B2 B1 A2 V1R 2 K1M BLK BLK RED A1 R C 3 L BLK 6 ORG 4 H 2 RED 3 1 WHT 1 X2M GRN/YLW M1C H t° 4 1 POWER SUPPLY ~ 50Hz 220V-240V RED S1T F1U WHT S A2 L RED N N 6 M 1~ YLW C11R WHT RED BLK L A1 RED 5 BLK 3.15A L 4 WHT RED 3 3 3 GRN/YLW 2 2 C BLU RED RED F1S C11R. 4CuT HEAT EXCHANGER OUTDOOR TEMPERATURE THERMISTER FILTER MUFFLER HEAT EXCHANGER LIQUID STOP FIELD PIPING VALVE (6.7CuT GAS STOP VALVE WITH SERVICE PORT ACCUMULATOR REFRIGERANT FLOW COOLING COMPRESSOR REFRIGERANT FLOW COOLING 4D065584B Room Air Conditioners J-Series 4D065585B 9 .1 Indoor Unit FTN50JV18 FTN60JV18 INDOOR UNIT INDOOR UNIT (7.4CuT) (6.9CuT) (7.9CuT) 12.9CuT) (12.9CuT) HEAT EXCHANGER HEAT EXCHANGER THERMISTOR ON HEAT EXCH.4CuT) M FAN MOTOR FIELD PIPING (12.4CuT M LIQUID STOP VALVE FIELD PIPING (6.7CuT PROPELLER FAN 6.4CuT) 6.EDHK011026 Piping Diagrams 6.4CuT CAPILLARY TUBE FIELD PIPING (12.5CuT GAS STOP VALVE WITH SERVICE PORT ACCUMULATOR COMPRESSOR FIELD PIPING (15.7CuT 12.2 Outdoor Unit RN50JV1 RN60JV1 OUTDOOR UNIT OUTDOOR UNIT M 6. THERMISTOR ON HEAT EXCH. CROSS FLOW FAN CROSS FLOW FAN FIELD PIPING FIELD PIPING (6.7CuT 12.7CuT) (15.4CuT FILTER 9.4CuT CAPILLARY TUBE PROPELLER FAN 12.4CuT) 6.9CuT 9.7CuT) REFRIGERANT FLOW COOLING REFRIGERANT FLOW COOLING 4D051016M 4D051010F 6.5CuT 6.7CuT) M FAN MOTOR FIELD PIPING (12. Piping Diagrams 6.7CuT) MUFFLER MUFFLER 15. 48 2.0 22 5.63 4.0 27 7.65 5. 3D068369 10 Room Air Conditioners J-Series .93 3.05 1. shows nominal (rated) capacities and power input.62 1. (°C) TC : Total capacity (kW) SHC : Sensible heat capacity (kW) PI : Power input (kW) 1.69 3.51 5.48 2.54 6.16 4.27 5. 220 V) AFR 18.64 5.) EWB : Entering wet bulb temp.38 4.86 4.93 4.76 1.44 4.05 1. 3D068368 FTN60JV18 + RN60JV1 (50 Hz.12 4. Corresponding refrigerant piping length : 7.37 19.62 4.99 1.91 3.21 2.39 5.Capacity Tables EDHK011026 7.41 5.58 5.0 20 6. 3. (Figures out of the tables should not be used for calculation.82 1.91 1.70 1.55 4.77 24.39 5.62 4.04 4.70 4.1 Cooling Only FTN50JV18 + RN50JV1 (50 Hz.82 1.35 4.0 32 6.49 2.26 5.) 4.73 4.65 6. please calculate them with around values in direct proportion. PI and SHC must be calculated by interpolation using the figures in the above tables.06 2.54 1.88 7.55 4.23 7.27 2.0 25 5.69 3.43 2.79 1.72 7.10 4.39 4.65 1.74 1.49 2.81 3.04 6. Ratings shown are net capacities which include a deduction for indoor fan motor heat.36 2.52 1.94 1.21 6.74 8.55 4. 5.16 4.83 1.53 1.64 5. 220 V) AFR 17.59 5.66 4.60 1.0 32 8.73 7.42 6.47 4.71 6.01 4.0 27 6.79 4.93 3.06 3.42 3. TC. (°C) EDB : Entering dry bulb temp.5 m Level difference : 0 m 6.07 7.91 7.64 4.60 2.94 3.66 5.86 1.19 5.06 7.32 4.72 7.73 1.24 4.35 16.09 5.10 4.02 6.55 4.79 1.92 1.0 30 8.30 2.65 1.43 3.57 5.285 INDOOR OUTDOOR TEMPERATURE (°CDB) EWB EDB 20 25 30 32 35 40 °C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.71 2. (°C) EDB : Entering dry bulb temp.27 5.91 3.78 Symbols NOTE: AFR : Airflow rate (m³/min.40 3.71 1.85 4.44 4.52 5.70 1.48 4. 2.86 4.0 25 7.91 1.88 6.85 1.74 1.) BF : Bypass factor EWB : Entering wet bulb temp.10 2.16 4.37 22.93 4.42 3. Corresponding refrigerant piping length : 7.63 2.41 4.16 1.17 4.53 5.03 6.90 7.5 BF 0.43 3. Capacities are based on the following conditions.01 1.55 2.76 19. About SHC which are not mentioned on the table.39 24.280 INDOOR OUTDOOR TEMPERATURE (°CDB) EWB EDB 20 25 30 32 35 40 °C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.37 2.42 1.40 Symbols AFR : Airflow rate BF : Bypass factor NOTE: (m³/min. About SHC which are not mentioned on the table.66 3.36 18.11 1. Capacities are based on the following conditions.05 6.26 2.14 7.88 1.75 18.56 4.76 22.06 1.78 4.95 1.28 5.13 7.20 5.36 2.26 1.85 1.54 1.85 6.58 1. TC.41 4. 2.56 5.67 3.65 3.89 4.08 3.0 30 6.30 3.79 4.67 3. shows nominal (rated) capacities and power input.18 3.21 6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.) 4.10 6.29 6.5 m Level difference : 0 m 6.11 6.25 2.22 6.42 4.33 3.17 4. PI and SHC must be calculated by interpolation using the figures in the above tables.05 3.0 22 7.88 1.01 1.0 20 5.95 1. (Figures out of the tables should not be used for calculation.59 1.52 5.50 4.87 6. 3.45 4.11 6.67 3.47 4.46 1.84 3.23 4.29 6.66 1.18 3.18 3.40 5.43 2.55 2.41 2.92 4.5 BF 0.68 1. please calculate them with around values in direct proportion.77 2. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 5. Capacity Tables 7. (°C) TC : Total capacity (kW) SHC : Sensible heat capacity (kW) PI : Power input (kW) 1.74 16.16 3.36 2.44 3.24 4.73 1.83 1. 8 Range of the Refrigerant Additional Charge 5 10 15 20 25 30 Piping length (m) (R12428) 7.1 50 Class R-410A (50 class) Capacity correction factor 1 0.2 Capacity Tables Capacity Correction Factor by the Length of Refrigerant Piping (Reference) The cooling capacity of the unit has to be corrected in accordance with the length of refrigerant piping.EDHK011026 7.2. The graphs show the factor when additional refrigerant of the proper quantity is charged.9 0.2. Room Air Conditioners J-Series 11 .2 60 Class R-410A (60 class) Capacity correction factor 1 0. (The distance between the indoor unit and the outdoor unit) 7.8 Range of the Refrigerant Additional Charge 5 10 15 20 25 30 Piping length (m) (R12429) Note: 1.9 0. 4 0 10 14 20 23 28 30 Notes: Indoor temp.5m • Level difference 0m • Air flow rate High 4D063906C 12 Room Air Conditioners J-Series . Operation Limit RN50/60JV1 50 46 Pull-down period 30 Continuous operation Outdoor temp. (˚CWB) The graph is based on the following conditions. (˚CDB) 40 20 19. • Equivalent piping length 7.Operation Limit EDHK011026 8. 27°CDB / 19°CWB Outdoor . The data are based on the conditions shown in the table below. Sound Level 9. Cooling Indoor . 2.1 Measuring Location Indoor Unit Outdoor Unit 1m 0. 35°CDB / 24°CWB Room Air Conditioners J-Series Piping Length 5m 13 .8 m 1m (R1759) Note: (R1003) 1.EDHK011026 Sound Level 9. Operation sound is measured in an anechoic chamber. N IS ALREADY RECTIFIED ) 50 OPERATING CONDITIONS NC-40 POWER SOURCE 40 220V 50Hz JIS STANDARD 50Hz 220V NC-30 30 NC-20 20 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) 8000 4D068091 Room Air Conditioners J-Series .2.0002µ bar) SCALE 50Hz 220V~240V (H) 50Hz 220V~240V (L) A 47 36 NC-60 NC-50 ( B.N IS ALREADY RECTIFIED ) 50 OPERATING CONDITIONS NC-40 POWER SOURCE 40 220V~240V 50Hz JIS STANDARD STANDARD EXTERNAL STATIC PRESSURE 50Hz 220V~240V(H) NC-30 30 50Hz 220V~240V(L) NC-20 20 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 9.2 Octave Band Level 9.0002µ bar) NC-60 70 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) 8000 4D068090 OCTAVE BAND SOUND PRESSURE LEVEL dB(0dB=0.0002µ bar) OCTAVE BAND SOUND PRESSURE LEVEL dB(0dB=0.Sound Level EDHK011026 9.0002µ bar) FTN50JV18 OVER ALL ( dB ) NC-60 60 NC-50 SCALE 50Hz 220V A 52 ( B.G.G.N IS ALREADY RECTIFIED ) 50 OPERATING CONDITIONS NC-40 POWER SOURCE 40 220V~240V 50Hz JIS STANDARD 50Hz 220v~240V(H) 50Hz 220v~240V(L) NC-30 30 NC-20 20 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) 4D066673B 8000 Outdoor Unit RN60JV1 70 70 OVER ALL ( dB ) NC-60 60 NC-50 SCALE 50Hz 220V A 50 ( B.N IS ALREADY RECTIFIED ) 50 OPERATING CONDITIONS NC-40 POWER SOURCE 40 220V 50Hz JIS STANDARD 50Hz 220V NC-30 30 NC-20 APPROXIMATE THRESHOLD HEARING FOR CONTINUOUS NOISE 63 14 OVER ALL ( dB ) 60 4D058780C 8000 RN50JV1 20 OCTAVE BAND SOUND PRESSURE LEVEL dB(0dB=0.1 Indoor Unit FTN60JV18 70 OVER ALL ( dB ) 60 SCALE 50Hz 220V~240V (H) 50Hz 220V~240V (L) A 45 35 NC-50 ( B.G.2.2 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND SOUND PRESSURE LEVEL dB(0dB=0.G. 5 43 0.2 FTN60JV18 RN60JV1 50 .4 65 0.Volts Voltage range MCA MFA LRA RLA W FLA W FLA FTN50JV18 RN50JV1 50 . 198 V MAX.8 50 0. RLA : Rated load amps (A) OFM : Outdoor fan motor IFM : Indoor fan motor FLA : Full load amps (A) W : Fan motor rated output (W) 3D067567B Room Air Conditioners J-Series 15 .220 MIN. 242 V 12. 4.5 25 54 9. fuse amps (A) LRA : Locked rotor amps (A) 1. Indoor temp.2 15 33 6. Maximum allowable voltage unbalance between phases is 2%. 3. 198 V MAX. 35°CDB.6 43 0. Instead of fuse. 2.EDHK011026 Electric Characteristics 10. Select wire size based on the larger value of MCA. Electric Characteristics Unit combination Power supply Compressor OFM IFM Indoor Outdoor Hz . use circuit breaker. circuit amps (A) MFA : Max. RLA is based on the following conditions. 242 V 9.2 SYMBOLS: NOTE: MCA : Min. 27°CDB / 19°CWB Outdoor temp.220 MIN. Installation Manual 11.Installation Manual EDHK011026 11.1 Safety Precautions 16 Room Air Conditioners J-Series . 2 50 Class Room Air Conditioners J-Series 17 .EDHK011026 Installation Manual 11. Installation Manual 18 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Installation Manual Indoor/outdoor Unit Installation Drawings Room Air Conditioners J-Series 19 . Installation Manual 20 EDHK011026 Room Air Conditioners J-Series EDHK011026 Room Air Conditioners J-Series Installation Manual 21 Installation Manual 22 EDHK011026 Room Air Conditioners J-Series EDHK011026 Room Air Conditioners J-Series Installation Manual 23 . Installation Manual 24 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Installation Manual 3PN10898-2G Room Air Conditioners J-Series 25 . 3 60 Class 26 Room Air Conditioners J-Series .Installation Manual EDHK011026 11. EDHK011026 Installation Manual Indoor/outdoor Unit Installation Drawings Room Air Conditioners J-Series 27 . Installation Manual EDHK011026 Indoor/outdoor Unit Installation Drawings 28 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Installation Manual 29 . Installation Manual 30 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Installation Manual 31 . Installation Manual 32 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Installation Manual 33 . Installation Manual EDHK011026 3PN10898-4G 34 Room Air Conditioners J-Series . EDHK011026 Operation Manual 12. Operation Manual Room Air Conditioners J-Series 35 . Operation Manual 36 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 37 . Operation Manual 38 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 39 . Operation Manual 40 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 41 . Operation Manual 42 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 43 . Operation Manual 44 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 45 . Operation Manual 46 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 47 . Operation Manual 48 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 49 . Operation Manual 50 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Room Air Conditioners J-Series Operation Manual 51 . Operation Manual 52 EDHK011026 Room Air Conditioners J-Series . the air conditioner may stop operating on a sudden large voltage fluctuation. You should wait for about 3 minutes. While the air conditioner is not in operation: • When the outdoor temperature is very high. furniture. The outdoor unit emits water or steam. Explanation • This is to protect the air conditioner. • When ON/OFF button was pressed soon after operation was stopped. refer to “To set the batteries” is low. After operation is stopped: • The outdoor fan continues rotating for another 60 seconds for system protection. press the reset button after the blacked out. Replace all the batteries with new size AAA The remote controller sensitivity alkaline batteries. or cigarettes are absorbed into the unit and discharged with the airflow. This happens when the air in the room is cooled into mist by the cold airflow during cooling operation. (OPERATION lamp is on. The display runs out of control. A “PISHI-PISHI” squeaking • Expansion and contraction of plastic parts caused by sound is heard when the system temperature change makes this noise.EDHK011026 Operation Manual Trouble Shooting These cases are not troubles.) The display is low in contrast or * If the reset button is provided. • When the mode was reselected. the outdoor fan starts rotating for system protection.) The outdoor fan rotates while the air conditioner is not in operation. The following cases are not air conditioner troubles but have some reasons. The indoor unit gives out odour. Case Operation does not start soon.) For system protection. batteries are replaced. This happens when smells of the room. (page 7. It automatically resumes operation in about 3 minutes. No remote controller signals are • The batteries are dying and the remote controller is displayed. The operation stopped suddenly. For details. of this manual. You may just continue using it. Consult the service shop where you bought the air conditioner. (If this happens. malfunctioning. we recommend you to have the indoor unit washed by a technician. is in operation or after the stop of operation 20 Room Air Conditioners J-Series 53 . Mists come out of the indoor unit. In COOL or DRY mode • Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips. Operation Manual 54 EDHK011026 Room Air Conditioners J-Series . EDHK011026 Operation Manual 3PN10897-5D Room Air Conditioners J-Series 55 . 2 Outdoor Unit Option Name 56 50 Class 60 Class KKP937A4 KKP945A4 KPW945A4 Room Air Conditioners J-Series .1 Option List 13.Optional Accessories EDHK011026 13.1.1. Optional Accessories 13.1 Indoor Unit Option Name 50/60 Class 1 Air-Purifying Filter with Photocatalytic Deodorizing Function without Frame KAF952B42 (KAF952A42) 2 Remote Controller Loss Prevention with Chain 1 Drain Plug 2 Air Direction Adjustment Grille KKF917A4 13. 2 Installation Manual 13.EDHK011026 Optional Accessories 13.1 KKP945A4 3P089958-1B Room Air Conditioners J-Series 57 .2. ) m t ore han 100 Installation of Louvers Caution Attach the louvers overlapping the standard grill. If exhaust blows directly on vegetation Space Needed for Installation A minimum of 100mm is needed between the back of the outdoor unit and any obstructions (walls. etc. (3) Installation complete (3) Installation complete 3P089958-2C 58 Room Air Conditioners J-Series . O The attachment screws are in the louvers.7.Optional Accessories EDHK011026 13. (2) Install the louver pointed up. O Overlap the standard grill and screw both in together. O The attachment screws are in the louvers. so be sure to install the standard grill. which is dangerous. Installing the louvers without the grill would allow hands to enter the fan area.5kW class) M5x4screws(8.2. When installing near the border to a neighbor's house If exhaust blows directly on passers-by because outdoor unit is installed facing a road. (2) Install the louver pointed down. (1) Remove the 4 attachment screws from the standard grill. O Overlap the standard grill and screw both in together. When pointing up When pointing down (1) Remove the 4 attachment screws from the standard grill.0/9.2 KPW945A4 „ Before installation Check the following parts Name Louver Truss tapping screw Installation manual 1piece M4x4screws(max.0kW class) 1piece Shape Quantity „ Installation Procedure Selection of Installation Location Use when installing in a location that meets the following conditions. . 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage. 2-18-1. LTD. 2.AK.. If you need to install the outdoor unit close to the sea shore. Ltd. Dealer Head Office: Umeda Center Bldg. If the outdoor unit is to be installed close to the sea shore. COOLING. such as acid gas or alkaline gas. Prior to purchase. are produced. EDHK011026 Printed in Japan 06/10/0007 FS. and is suitable for use. RESIDENTIAL AIR CONDITIONING EQUIPMENT. restrict or modify the application of any local legislation. distributor and/or retailer. Ltd. COMMERCIAL HEATING EQUIPMENT. Be sure to follow these instructions and warnings. Air conditioners should not be installed in areas where corrosive gases. HEATING. electrical shock. direct exposure to the sea breeze should be avoided.. Read the User's Manual carefully before using this product. JQA-1452 Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management. does not have control over which products are exported to and used in a particular country. Ask a qualified installer or contractor to install this product. Kita-ku. contact your local distributor. This statement does not purport to exclude.’s products are manufactured for export to numerous countries throughout the world. AIR CONDITIONING MANUFACTURING DIVISION JMI-0107 Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING. Konan. in the region where the product will be used. MARINE TYPE CONTAINER REFRIGERATION UNITS.B . Daikin Industries. please contact your local importer. Organization: DAIKIN INDUSTRIES. The User's Manual provides important safety instructions and warnings. Minato-ku. Tokyo. If you have any enquiries. Nakazaki-Nishi. HEAT RECLAIM VENTILATION. fire or explosion. 108-0075 Japan http://www. Improper installation can result in water or refrigerant leakage. please therefore confirm with your local authorised importer. COMPRESSORS AND VALVES. Osaka.com/global_ac/ c All rights reserved Specifications. fire or explosion. 2-4-12. designs and other content appearing in this brochure are current as of June 2010 but subject to change without notice. Do not try to install the product yourself. Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Cautions on product corrosion 1. AIR CLEANING EQUIPMENT.Warning Daikin Industries.daikin. Use only those parts and accessories supplied or specified by Daikin. distributor and/or retailer whether this product conforms to the applicable standards. Ask a qualified installer or contractor to install those parts and accessories. REFRIGERATING EQUIPMENT. electrical shock.
Copyright © 2024 DOKUMEN.SITE Inc.