CT00-000.814.30.02.02.pdf



Comments



Description

© Siemens, 2008All documents may only be used for rendering services on Siemens Healthcare Products. Any document in electronic form may be printed once. Copy and distribution of electronic docu- ments and hardcopies is prohibited. Offenders will be liable for damages. All other rights are re- served. Print No.: SiemensWalz SOMATOM Definition Hardcopy Cameras Installation and Startup CT 2008 CT00-000.814.30.02.02 Replaces: CT00-000.814.30.01.02 English Doc. Gen. Date: 05.09 n.a. H WS CS SD CO Camera information with SOMARIS/7 VA20;VA26 © Siemens, 2008 This document is valid for the following CT systems: SOMATOM Definition SOMATOM Definition AS SOMATOM Definition AS+ SOMATOM Definition AS20 07740769 10430603 2 Copyright / Version / Disclaimer SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 2 of 260 1Copyright / Version / Disclaimer Copyright “© Siemens, 2008“ refers to the copyright of a Siemens entity such as Siemens Aktienge- sellschaft - Germany, Siemens Shenzhen Magnetic Resonance Ltd. - China, Siemens Shanghai Medical Equipment Ltd. - China, Siemens Medical Solutions USA Inc. - USA and/or Siemens Healthcare Diagnostics Inc. - USA. Document Version Siemens reserves the right to change its products and services at any time. In addition, manuals are subject to change without notice. The hardcopy documents corre- spond to the version at the time of system delivery and/or printout. Versions to hardcopy documentation are not automatically distributed. Please contact your local Siemens office to order current version or refer to our website http://www.healthcare.siemens.com. Disclaimer Siemens provides this documentation “as is“ without the assumption of any liability under any theory of law. The installation and service of equipment described herein requires superior understand- ing of our equipment and may only be performed by qualified personnel who are specially trained for such installation and/or service. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Table of Contents 3 Page 3 of 260 0Table of Contents 1 _______ General Hardcopy Camera Information______________________________ 7 HCC Information for SOMATOM Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Scope of applicability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Modality. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Image quality and optical density check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 General image quality information (LUT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Density verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Reference films . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Description of Correction LUT Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Additional and unnecessary LUT files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Postscript Hardcopy Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Restrictions and Known Effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Postscript Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Look-Up Tables (LUT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 2 _______ Specific Camera Information - Agfa________________________________ 30 Agfa Drystar AXYS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 SCU / modality software configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 SCP / hardcopy camera configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . . 33 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Agfa Drystar 5503. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 41 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Agfa Drystar 5500. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 49 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Agfa Drystar 5302. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 57 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Agfa Drystar 5300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 63 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Agfa Drystar 3000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 70 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 4 Table of Contents SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 4 of 260 Agfa LR5200 / MG3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 76 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Agfa LR5200 / LR DICOM Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 82 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 3 _______ Specific Camera Information - Codonics____________________________ 87 Codonics Horizon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 90 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 4 _______ Specific Camera Information - Fuji_________________________________ 94 Fuji Drypix 7000 / 5000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 97 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Fuji Drypix 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 105 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Fuji Drypix 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 112 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Fuji Drypix 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 119 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Fuji FM DPL/FN-PS551 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 128 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 5 _______ Specific Camera Information - Kodak _____________________________ 134 Kodak DryView 6800. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Table of Contents 5 Page 5 of 260 SCU / modality software configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 SCP / hardcopy camera configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 137 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Kodak DryView 5800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 SCU / modality software configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 SCP / hardcopy camera configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 145 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Kodak DryView 8900 (small border). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 154 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Kodak DryView 8700-Plus / PACS Link MIM 200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 159 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Kodak DryView 8700-Dual / PACS Link MIM 9410. . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 166 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 Kodak DryView 8200 / PACS Link MIM 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 172 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 Kodak DryView 8100 / PACS Link MIM 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 179 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Kodak DryView 8150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 187 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Kodak KELP 2180/PACS Link MIM 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 194 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 6 _______ Specific Camera Information - Konica Minolta ______________________ 199 Konica Minolta DryPro 832. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 SCU / modality software configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 SCP / hardcopy camera configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 202 6 Table of Contents SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 6 of 260 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 Konica Minolta DryPro 793 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 212 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 Konica Minolta DryPro 771 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 219 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 Konica DryPro 751/752. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 227 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 7 _______ Specific Camera Information Sony________________________________ 232 Sony UP-DF 550. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 SCU / Modality Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 SCP / Hardcopy Camera Configuration (provided by OEM) . . . . . . . . . . . . . . . . . . 235 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 Sony UP-DF 500. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 SCU / modality software configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 SCP / hardcopy camera configuration (provided by OEM) . . . . . . . . . . . . . . . . . . . 242 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 8 _______ Specific Printer Information Epson _______________________________ 245 Epson AcuLaser C 4200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 Printer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 Modality Configuration (Postscript Driver) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 Hardcopy Printer Identification (provided by OEM) . . . . . . . . . . . . . . . . . . . . . . . . . 249 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 9 _______ Specific Printer Information Hewlett Packard _______________________ 252 Hewlett Packard Color Laser Jet 4700N. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252 Printer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 Modality Configuration (Postscript Driver) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 Hardcopy Printer Identification (provided by OEM) . . . . . . . . . . . . . . . . . . . . . . . . . 257 Image Quality and Optical Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 10 ______ Changes to Previous Version ____________________________________ 260 Changes to Previous Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 7 Page 7 of 260 1- 1General Hardcopy Camera Information HCC Information for SOMATOM Definition 0 General information 0 Acronyms and abbreviations Block Diagram SOMATOM Definition Fig. 1: System references • Refer to Siemens Medical Solutions Intranet, UPTIME Services AE Title Application entity title BU Business Unit (Modality) DCS DICOM Conformance Statement DICOM Digital Imaging and Communication in Medicine HW/SW Hardware/Software HCC Hardcopy Camera LAN Local Area Network LUT Lookup Table OEM Original Equipment Manufacturer SCP Service Class Provider SCU Service Class User TCP/IP Transfer Control Protocol/Internet Protocol 8 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 8 of 260 • Product-specific technical documentation Hardware components • Ethernet switch ATI-FS708 (part no.: 30 79 332) • Cable, straight-through, S/UTP RJ45 (5m.; part no.: 30 74 515) • Cable, straight-through, S/UTP RJ45 (30 m.; part no.: 30 74 523) or • Refer to Siemens Medical Solutions Intranet, UPTIME Services • Product-specific technical documentation Restrictions and known effects NOTE Sending film sizes that are not available at the customer site may cause problems at the camera site. For this reason, it is recommended that you delete these film sizes for portrait and landscape formats. NOTE The Grayscale Standard Display Function (GSDF) is imple- mented for printing and imaging. No Presentation LUTs are available. For this reason, the DICOM Presentation LUT is not released. NOTE The use of the presentation LUT has to be disabled by local service for configuring LUT files. NOTE The density values for the image quality were measured with a calibrated densitometer X-Rite 301. The result of the mea- surement from other densitometers used may differ from the absolute density values as described in the tables. NOTE Print the 17 graystep test image to check the modality and camera adjustment according to the description. Verify the results using the reference values for max. density 2.80 listed in the table. This is also part of the acceptance test. NOTE For additional Postscript Hardcopy Restrictions and Known Effects, refer to the Chapter on Postscript Hardcopy Informa- tion as well. (Restrictions and known effects / p. 8) © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 9 Page 9 of 260 Errors and warning messages Only certain errors and warnings have been tested for each hardcopy camera. These errors and warnings are described in the corresponding camera information. . Scope of applicability 0 Modality/system Hardcopy Cameras This table includes all hardcopy cameras using DICOM basic print. Device type Modality (SCU) Product name SOMATOM Definition Modality host name/console CT host name ICS (syngo Acquisition Workplace) IES (syngo CT Workplace; optional) IRS (Image Reconstruction System) Manufacturer Siemens Med CT SW revision Somaris 7 VA20A (syngo-based VE32A) Somaris 7 VA26 (syngo-based VE32B) Conformance statement EDM 10094810-EKL-YK0-01 10 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 10 of 260 Manufac- turer HCC name Software validity VA20 VA26 V.... V.... AGFA Drystar AXYS X X AGFA Drystar 5503 X X AGFA Drystar 5500 X X AGFA Drystar 5302 X X AGFA Drystar 5300 X X AGFA Drystar 3000 X X AGFA LR5200 / LR DICOM Controller X X AGFA LR5200 / MG 3000 X X CODONICS Horizon X X FUJI Drypix 7000/5000 X X FUJI Drypix 4000 X X FUJI Drypix 3000 X X FUJI Drypix 2000 X X FUJI FM DPL / FN-PS 551 X X KODAK DryView 6800 X X KODAK DryView 5800 X X KODAK DryView 8900 (small border) X X KODAK DryView 8700-Plus / PACS Link MIM 200 X X KODAK DryView 8700-Dual / PACS Link 9410 X X KODAK DryView 8200 / PACS Link MIM 200 X X KODAK DryView 8150 X X KODAK DryView 8100 / PACS Link MIM 200 X X KODAK KELP 2180 / PACS Link MIM 200 X X KONICA MINOLTA DryPro 832 X X © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 11 Page 11 of 260 X = hardcopy camera is released N/A = hardcopy camera is not released NOTE The use of non-released hardcopy cameras in conjunction with BU products is prohibited and does not meet the requirements specified. Hardcopy Printer This table includes all hardcopy cameras using Postscript. For configuration of one of these printers - refer to the specific documents for these printers X = hardcopy printer is released N/A = hardcopy printer is not released NOTE The use of a non-released hardcopy printer in conjunction with CT products is prohibited and does not meet the require- ments specified. KONICA MINOLTA DryPro 793 X X KONICA MINOLTA DryPro 771 X X KONICA DryPro 751/752 X X SONY UP-DF550 X X SONY UP-DF500 X X Manufac- turer HCC name Software validity VA20 V... V.... V.... EPSON AcuLaser C4200 X X Hewlett Packard Color Laserjet 4700N X X Xerox Phaser 6360 DP n.a. n.a. Manufac- turer HCC name Software validity VA20 VA26 V.... V.... 12 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 12 of 260 DICOM associations A DICOM association is a network connection between 2 DICOM applications. The asso- ciation is established and released by the SCU and may be aborted by the SCU or SCP. The maximum number of associations for each HCC device is defined in the DCS. The maximum number of associations depends on the configuration and may be extended by increasing the number of gateways connected to the printer device. In a DICOM network environment, there are two ways to connect a modality (SCU) to an HCC device (SCP). Case 1: The association will always be opened. Assuming that this behavior applies to all modalities (connected to the same HCC device), the number of modalities has to be equal to or less than the maximum number of supported associations. Case 2: The association will be opened (and closed) on demand. Assuming that this behavior applies to all modalities (connected to the same HCC device), the number of modalities may be greater than the maximum number of supported associations. This num- ber will be shared by the modalities. The association open-close behavior is unknown to other non-SIEMENS modalities. Under optimum circumstances, the number of modalities is equal to or less than the maximum number of supported associations. The association is always opened by the SCU (case 1) If the associations are always opened by the SCU for each configured HCC device, the association is reserved for this SCU only. If the maximum number of associations = 1, and another modality never releases the asso- ciation, this HCC device is always reserved for this modality. The association is opened and closed on demand (case 2) The associations will be opened (and closed) on demand by the SCU for each configured HCC device via the product name. Special cases (compare also to case 1): If the number of modalities configured in the HCC device is greater than the maximum num- ber of supported associations, some modalities will not be able to print. The printing func- tion depends on the access time and release mechanism of each connected modality (e.g., the maximum number of supported associations = 1, the number of modalities = 2. During access by the first modality, access by the second modality is denied and connectivity fails, and vice versa). If other modalities do not release the associations, the shareable number of associations decreases. Modality 0 Hardware and software prerequisites All hardware and software prerequisites are included in the <modality> product delivery volume. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 13 Page 13 of 260 Parameters For software configuration, HCC data/parameters and possibly additional film matrix prop- erties (syngo: filming properties) are required for software configuration. Modality data and configuration parameters HCC Data and Configuration Parameters 1 1 The values for these parameters are part of the specific HCC information Example: Kodak DryView 8300 Properties Example Supplier Port number 104 Default entry AE title PR_”Hostname” Default entry TCP/IP address xxx.x.x.xxx Network administrator Application Entity Properties Display Supplier AE Title K8300 Network administrator or HCC service Port number 5040 HCC Service HC Device / General settings Display Supplier Type DICOM printer Default entry Class (printer spec file name) kodak8300 Default entry DICOM Node dv8300 Default entry Filming properties Display Supplier Hold printed Film Jobs 10 Default entry Min. density 20 Default entry Pixel Size [1/1000 mm] 85.0 x 85.0 Default entry Film Sheet Formats, Portrait Number of Pixels [columns x rows] 8" x 10" 2256 x 2676 Default entry Film Sheet Formats, Landscape Number of Pixels [columns x rows] 8" x 10" 2736 x 2136 Default entry 14 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 14 of 260 Film matrix properties The settings for filming properties depend on the class selected (DICOM camera). A pull-down menu is provided for DICOM-class cameras. Select your DICOM camera type. A specific file for this type is loaded and the "filming properties" are shown. Changing the "filming properties" will affect the camera site and may not meet the requirements. Do not make any changes, unless otherwise instructed. NOTE Filming properties are "pixel size" and "media sheet size"; this information is required for image scaling and cannot be changed. Software configuration • The following information is required: - Host Name - TCP/IP address - Application entity title - Port number of the DICOM remote host (DICOM laser camera) The AE title, port number and camera type have to be provided by the local camera service. syngo software configuration and laser camera 1. Select options in the menu line 2. Navigate to local service The Siemens Service Software Authentication platform is displayed 3. Enter the password and click ”OK” The Home Menu Platform of the syngo Service Software is displayed 4. Click ”Configuration” The Local Service Configuration List of system options is displayed 5. Click DICOM ”General” 6. Click ”>” The local Application Entity Title platform is displayed Medium type Blue film Default entry Film destination Processor Default entry Color appearance Grayscale 8 bit Default entry Background Black Default entry Transformation No magnification Default entry Filming properties Display Supplier © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 15 Page 15 of 260 7. Provide the Local Camera Service with the information in the field ”Print (SCU) AE Title PR_”Hostname” 8. Click ”Save”; ”>”; ”Finish” The Configuration Setup platform is displayed 9. Click Local Host ”TCP/IP LAN” The local Service Configuration TCP/IP LAN platform is displayed 10. Provide the Local Camera Service with the information in the ”IP address” field (scroll down menu for IP address but do not select it) 11. Click ”Finish” The Configuration Setup platform is displayed 12. Select DICOM Print Devices The Local Service Hardcopy Device platform is displayed 13. Enter the host name and TCP/IP address of the laser camera (provided by the camera manufacturer) 14. Click ”Test” to test IP communication (ping) 15. Click ”Save” Host properties successfully saved 16. Click ”OK” 17. Click ”>” The General Note Properties Dialog platform is displayed 18. Under logical name: Enter the logical name of the laser camera 19. Select the host and choose the previously defined host name in the hardcopy device platform 20. Under application entity properties: Enter the AE title in the edit AE title field (provided by the camera manufacturer) 21. Enter the Port Number (provided by the camera manufacturer) 22. Click ”Add” 23. Click ”Save” DICOM node properties successfully saved 24. Click ”OK” 25. Select the logical name again and click ”Verification” to test the DICOM communication (mc3echo) 26. Click ">" The camera-specific parameter platform is displayed. 27. HC device: Enter the camera name 28. General settings: /type: DICOM printer 29. /class: e.g., agfadrystar3000, or refer to specific HCC information 30. Filming properties: 16 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 16 of 260 - Hold printed film job, 10 = default; (max. = 10) (films can be printed again) - Min. density 20 = default; (can be changed in increments of 1) - Pixel size (changes not allowed) - Film Sheet Formats Portrait (do not modify and/or add film sizes, select and delete film sizes that are not available at the customer site) - Medium type, blue film = default; clear film; paper - Film destination, processor = default; magazine - Color appearance, monochrome = default; (select color for printers that support and use color media only, e.g., Drystar2000; Codonics) - Background, black =default; white - Transformation no magnification = default; do not change this value; except for Kodak DV8900; replicate; (do not change any other values under filming properties) 31. Click "Save" Caution: Please wait for the message "device properties successfully saved" 32. Click ”OK” 33. Click ”Finish” The Configuration Setup platform is displayed 34. Click ”>” to proceed and select the next marked DICOM ”HC Overview” 35. Click ”Finish” The Configuration Setup platform is displayed 36. Click LUT files The LUT platform is displayed. NOTE If new LUT files for one or more modalities are available on a removable medium, e.g., floppy or CD, these files can be selected on the source drive and copied to the dependent LUT directories on the local host. Unnecessary LUT files can be removed from the LUT directories on the local host. 37. Click ">" Usage of Presentation LUT platform is displayed 38. Select disable 39. Modifications are necessary for additional image impressions only. NOTE Only the topic CT image and SC image are relevant. Depend- ing on the camera, specific entries have to be made. If noth- ing else is mentioned, set the CT image and SC image to "CTLUT" and "2.80" for maximum density. The entries for BU image and SC image have to be identical. 40. Overall maximum density: - 3.00 = default (depends on the max. possible value of the max. density of all image types) © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 17 Page 17 of 260 41. Interpolation for printing: - Bilinear mode = default; #Smoothing Type - Replicate #Smoothing Type - Cubic 0, 2, 3, 4 = concerns cubic mode only 42. When changes are made, click "Save" 43. Click "Finish" 44. Click "Home"; the system automatically restarts the application NOTE This may take some time. Confirm warnings with "OK." 18 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 18 of 260 Image quality and optical density check 1.1 General image quality information (LUT) 0 Only standard LUT files are loaded. For importing/removing additional/unnecessary LUT files (see section ”Additional/unnecessary LUT files”) (LINK). The image data from the modality to the HCC is transformed/corrected by the LUTs, once in the modality and once in the HCC. As as result, the LUT has to be set on both sides: • Refer to the Siemens Medical Solutions Intranet, UPTIME Services • Product-Specific Technical Documentation Correction LUT is selected Density verification 0 There are two ways to check the LUT via the film density: The modality is configured to a specific correction LUT and the HCC is configured to linear curves. As an alternative, the modality is configured to a linear LUT and the HCC is config- ured to linear curves. Modality Image Type Correction LUT Max. density CT Image CT LUT 2.80 SC Image CT LUT 2.80 HCC Refer to the specific Camera Information "DICOM printer settings". The HCC Service performs the setting "LINEAR LUT" © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 19 Page 19 of 260 Density verification for CT Since these two checks are equivalent; it is sufficient to check the “specified density”. Checking the “HCC linearity” may be necessary if the desired density verification (1) shows deviations and the HCC setting needs to be changed. NOTE Even if the HCC service does not require a test image of the modality for the HCC setting, it is easier to check this setting - and possibly further HCC corrections - with the HCC linear- ity verification (2) than with the desired density verification (1). Only the HCC linearity LUT is effective. A graphical dis- play would now show the current HCC behavior only. This could be helpful for HCC Service. Density values for CT • Measure the density values in 17 gray levels in the IEC test image (Fig. 2 / p. 19) (for each film size). W:256; C:0; Fig. 2: Test image Check no. Verification for Modality adjustment Reference value CT Application Image Type Correction LUT Max. Density 1 Desired density CT Image CT LUT 2.80 Refer to the table for CTLUT 2 HCC linearity CT Image Linear 2.80 Refer to the table for lin- ear LUT 20 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 20 of 260 The density difference of the BU LUT (Ref. LUT) between steps 1, 2, and 3 has to be a minimum density value of 0.02. Test image 3 (SMPTE image) can be used for visual veri- fication (the 95% gray square has to be visible). Reference films 0 Reference film To create a reference film with the desired LUT adjustment, proceed as follows: 1. The layout is configurable under Option/Configuration/Filming layout 2. Use format 3.2; default center/width, for the film sheet Step CT LUT Linear LUT Ref. LUT Maximum Density Minimum Density Ref. LUT Maximum density Minimum density 1 0.20 0.23 0.17 0.20 0.23 0.17 2 0.23 0.26 0.20 0.36 0.40 0.33 3 0.28 0.32 0.24 0.53 0.56 0.49 4 0.35 0.39 0.31 0.69 0.73 0.64 5 0.43 0.48 0.38 0.85 0.90 0.80 6 0.52 0.57 0.47 1.01 1.06 0.96 7 0.63 0.69 0.57 1.18 1.23 1.12 8 0.75 0.81 0.69 1.34 1.40 1.28 9 0.88 0.95 0.82 1.50 1.57 1.44 10 1.04 1.11 0.97 1.66 1.73 1.59 11 1.21 1.28 1.14 1.83 1.90 1.75 12 1.41 1.49 1.33 1.90 2.07 1.91 13 1.64 1.72 1.56 2.15 2.23 2.07 14 1.88 1.97 1.79 2.31 2.40 2.23 15 2.13 2.22 2.04 2.48 2.57 2.38 16 2.44 2.54 2.34 2.64 2.73 2.54 17 2.80 2.90 2.70 2.80 2.90 2.70 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 21 Page 21 of 260 3. Select the "Viewing" tab, select Patient Browser, navigate to the folder "CT Reference Images" and view the test images: Use test images (technical images) without text and the three CT Medical Ref images (cerebrum, pancreas, (LWS) lumbar spine) with text and print the film sheet. (the DICOM command to the printer is always "magnification none") 4. Measure IEC test image 1 (Fig. 2 / p. 19) and verify the CTLUT using the table "Density values for modality CT” Segment layout: 5. Repeat this procedure with the linear LUT adjustment 6. If the reference images are not available, please load the reference images from H:\SITE_DATA\Reference-images\* in the storage device (import from offline) Description of Correction LUT Files 0 Description of Correction LUT Files for CT 1 2 3 4 5 6 Segment Image Window Center 1 IEC test image 1 (17 gray levels) 256 0 2 IEC test image 2 (50% gray field) 256 0 3 Test image 3 (SMPTE test pattern) 100 0 4 Pancreas (Abdomen) 520 104 5 Cerebrum (Head) 80 53 6 LWS (Spine) 440 56 Correction LUT LUT files with D min. 0.2 and D max. 2.80 Linear Linear LUT CT LUT Standard LUT; default for all cameras; adapts D min. of 0.2 CT02 vs. CT LUT Dark area = less contrast; darker; softer; white area = more con- trast CT03 vs. CT02 Dark area = less contrast; darker; softer; white area = more con- trast CT04 vs. CT LUT Dark area = more contrast; darker; sharper; white area: no changes 22 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 22 of 260 Additional and unnecessary LUT files 0 If new, released LUT files are available on a removable medium (e.g., floppy or CD). These files may be selected on the source drive and copied to the dependent LUT directories on the local system. Unnecessary LUT files may be removed from LUT directories on the local system. Importing LUT files 1. In Local Service Configuration platform, select LUT files 2. Select the (source) drive and the path where the appropriate LUT files are located 3. Select the destination LUT directory (correction LUT directory) which depends on the image type (CTImage). 4. By pushing the copy button, the selected LUT file will be transferred to CTImage type. 5. Repeat this procedure using the appropriate LUT files for SC Images. 6. Select the destination LUT directory (correction LUT directory) which depends on the image type (SCImage). 7. Pushing the copy button transfers the selected LUT file to SCImage type. 8. Confirm the message "Files successfully copied" by clicking "OK" Removing LUT files Unnecessary LUT files can be removed from LUT directories on the local host by selecting the appropriate LUT file and clicking the "Remove" button. • Click ">" CT05 vs. CT LUT Brighter; no changes in contrast for large window width; more contrast for head images (small window width) CT06 vs. CT LUT Brighter than CT5; white area = less contrast cthead1 LUT for head images, images smoother cthead2 vs. cthead1 Images smoother CT015 Adapts D min of 0.15 (for cameras which are not supported D min. command) CT017 Adapts D min. of 0.17 (for cameras which are not supported D min. command) CT LUTdry LUT for dry cameras; adapts D min. of 0.22 (5% visible in SMPTE test pattern) CT Lung LUT for lung images Correction LUT LUT files with D min. 0.2 and D max. 2.80 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 23 Page 23 of 260 Real Size Scaling This procedure should be performed after system installation and when the Hardcopy Camera is ready to print. The real size behavior has to be performed with each connected Hardcopy Camera. Real size scaling verification 1. Load the test image (water image phantom) into the viewer (e.g. 20 cm water phantom, generated with the constancy procedure by CT). 2. Insert Crosshair (Viewing Card: Tools) and copy the image to the film sheet (“copy image to film sheet” button). 3. Select film sheet format 1 X 1. 4. Select "Original Image" in the filming card and print the image. 5. Use a calibrated ruler to measure the crosshairs of the printed image. The results should correspond to the printed value underneath the scale with a tolerance of ±1% in both directions. Refer to the specific camera information. 24 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 24 of 260 Postscript Hardcopy Information 1.2 Restrictions and Known Effects 0 Restrictions NOTE Paper printouts are not allowed for medical diagnosis. NOTE Only one Adobe Postscript Printer can be installed on a 64-bit computer. More than one Postscript Printer Installation will not work. NOTE The adobe printer driver with the printer-specific description file has to be used. The paper printer is not linear in greyscale image print-out. Therefore the respective PSLUT Files has to be used to opti- mize the image quality for the print-out. The PSLUT files are: • EPSON_C4200_correction.lut • HP_LaserJet4700_linear.lut • Kyocera_FS_C5020N_Cor.lut • inv_CTLUT.lut NOTE Color graphic lines and markers (arrows) are difficult to iden- tify on paper. For CT applications (e.g calcium scoring) use the report of the applications to print out the images of the results. Known Effects n.a. Postscript Driver 0 General information The Printer Driver Installation of Somaris software includes the particular printer descrip- tion file. Both have to be performed directly in WINDOWS XP. The generic Adobe Post- Script Printer Driver is already preconfigured and also visible in Somaris as “SIEMENS.PD” printer. Only the postscript description file (ppd - file) for the specific printer has to be installed additionally. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 25 Page 25 of 260 Missing Installation of Adobe Postscript Driver V5.2 in Windows XP Installation of Adobe Postscript Alternatives for special printer setting Missing Installation of Adobe Postscript Driver V.5.2 in Windows XP If the “SIEMENS.PD” is not available (e.g. deleted), a new installation of this generic Adobe driver is required Log into your system with your administrator account. Navigate to folder: C:\Somaris\Tools\Postscript\XP64. Double-click the patch procedure: Install_Printer_Driver.bat Installation of Adobe Postscript Printer in Windows XP Log into your system with your administrator account. Navigate to folder: C:\Somaris\Tools\Postscript. Double-click the file PostScriptInst.exe click <browse> ----> "browse for folder " window appears. Select the appropriate post script printer name 1. HP Color Laser Jet 4700N select folder PPD\hp and click OK: A list of available HP - printers appears Select "hpmcpd25.ppd" and press Go The window is closed Restart system Login as administrator 2. Epson Aculaser C4200 select folder PPD\epson and click OK: A list of available EPSON printers appears Select "epalc420.ppd” and press Go The window is closed 26 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 26 of 260 “Configure the postscript printer driver as described in the part of printer informa- tion specific for the respective PS printer”. Restart system Login as administrator Configuration of Adobe Postscript Printer in Windows XP Start --> Settings --> Printers and Faxes click “SIEMENS.PD” with the right mouse button select properties change in “General” the name “SIEMENS.PD” to the appropriate printer name (e.g. HP4700N) click <OK> select e.g. "HP4700N" and with right mouse key select "Properties" The "HP4700N Properties"- window appears. Select: "Ports" and click <Add Port> "Printer Ports" window Select: "StandardTCP/IP Port" and "New Port" "Add Standard TCP/IP Printer Port Wizard" window appears, click <Next> Enter the IP address of the printer in the field: Printer Name or IP Address: xxx.xxx.xxx.xxx Port Name: Let Windows choose the port name. <Next> "Add Standard TCP/IP printer Port Wizard" window "Standard" and "Generic Network Card" is selected Click : <Next> Click : <Finish> <Close> "Printer port" window <Close> "HP4700N Properties" window 2. Epson Aculaser C4200 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 27 Page 27 of 260 Configure in Local Service Configuration Select "Paper Printer" in Configuration Menu. Select “Local service” -> configuration -> Paper Printer Deselect all paper printer media that the printer does not support. <save>, click “>” The “Printer Paper size Mapping” window appears select the appropriate printer in Configured Printers a table for mapping of paper sizes appears Assign the real names of the printer paper sizes to the fixed syngo paper size names. e.g. Printer Paper Size Mapping Configured Printer e.g. HP 4700N Syngo Paper Size Printer Paper Size Letter Small --> Letter A4 --> A4 Configure in Local Service Configuration <save>, <finish>, Select "Local service" -> configuration -> PS LUT Files Go to the PSLUT directory and select the specific Postscript LUT file for this printer (names of PS-LUTs, refer to the description specific to the printer): Select: "Use LUT for Postscript Printers" Select: “Use DICOM LUT for Postscript Printers” Select: "Use floating Zoom factors" Click : <Save> Click : <Finish> Click : <Home> Restart Somaris 28 General Hardcopy Camera Information SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 28 of 260 Look-Up Tables (LUT) 0 CT Reference Film and LUT To create a reference, film the images of the patient: “Reference Images” have to be used. It contains 3 test images and 3 medical images. Concerning the positions of the images on the paper, the order is from top left to right bottom. Test images cannot contain image text, medical images need the full text. The measured values are described in the specific Printer Information included in this doc- ument. Image Attributes for syngo-based modalities Precondition Segment Image Window Center 1 IEC test image 1 (17 gray levels) 256 0 2 IEC test image 2 (50% gray field) 256 0 3 Test image 3 (SMPTE test pattern) 100 0 4 Pancreas (Abdomen) 520 104 5 Cerebrum (Head) 80 53 6 LWS (Spine) 440 56 Max. Density 2.8 Max. Density overall 3.0 Interpolation for printing Bilinear Transformation No magnification Segment lines no Page number on print-out Not selected Layout divisions 2x3 Orientation portrait Image order Horizontal Paper size A4 Reference image Not selected Modality The modality has to be configured for image types “CT Image” and for “SC Image” to CTLUT. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO General Hardcopy Camera Information 29 Page 29 of 260 Postscript Printer LUT Real size scaling Load the test image (water image phantom) into the viewer (e.g. 20 cm water phantom, generated with the CT constancy procedure ). Insert crosshair with tool in viewer. Send this image from the viewer to the filming tab card and expose it on paper. Evaluate the printed paper. Search 2 scale lines of the crosshair with the largest possible distance to each other, separate in the x and y direction and noted as the desired value. Measure the distance with the ruler and compare the measured value with the described values written in the specific Printer Information included in this document. Image attributes for syngo-based modalities Printer The printer must be switched to black & white. In "Local service" -> configuration -> PS LUT Files The respective PS LUT file has to be selected Postscript Printer PS LUT file name Epson AcuLaser C4200 EPSON_C4200_correction.lut Hewlett Packard Color Laserjet 4700 HP_LaserJet4700_linear.lut Kyocera Ecosys FS-C5020N Kyocera_FS_C5020N_Cor.lut Xerox Phaser 6350 DP inv_CTLUT.lut Transformation No magnification Interpolation for printing Bilinear Segment lines no Page number on print-out Not selected Layout divisions 1x1 Orientation Portrait/landscape Paper size A4/Letter small Aspect ratio Original image Scale factor 100% 30 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 30 of 260 2- 2Specific Camera Information - Agfa Agfa Drystar AXYS 0 General Information 0 Block Diagram Fig. 3: Available Film Sizes Performance and Connections Associations Maximum number of associations supported: 10 Format Release status Film type Medium type 14" x 17" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 14" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 11" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 10” x 12” Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 8" x 10" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 31 Page 31 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, 4x5 format, Copies=1, default center/width, magnification type none. The optimum connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE European EMC Classification is Class A. NOTE Slight inhomogeneity visible in gray field NOTE Typical slight line structure of the thermo head is visible in technical image. NOTE Two edges of the diagnostic area are cut (approx 1 mm) for 8x10, 10x12, 11x14,14x17. NOTE The background command does not work properly. The back- ground is always white. Known effects NOTE The built in densitometer has to be set to X-Rite 301x to achieve the required image quality. SCU / modality software configuration 0 Time 74 sec Application Entity Properties Display Changes allowed AE Title AXYS Yes Port number 104 No 32 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 32 of 260 HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec file name) agfadrystar5503_AX YS No DICOM Node DSAXYS Yes Filming properties Display Changes allowed Hold printed film jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 50.0 x 50.0 No Film sheet formats, Portrait Number of pixels [columns x rows] 14" x 17" 6922 x 8368 14" x 14" 6882 x 6882 11" x 14" 5376 x 6922 10" x 12" 4880 x 5860 8" x 10" 3852 x 4880 In “define new” Do not modify/add Select only Delete only Film sheet formats, Landscape Number of pixels [columns x rows] 14" x 17" 8368 x 6922 14" x 14" 6882 x 6882 11" x 14" 6922 x 5376 10" x 12" 5860 x 4880 8" x 10" 4880 x 3852 Medium type Blue film Yes Film destination Processor No Color appearance Gray scale 8 bit No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 33 Page 33 of 260 NOTE Do not modify or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / hardcopy camera configuration (provided by OEM) 0 Identification Printer Settings Background Black Yes Transformation No magnification No Filming properties Display Changes allowed Device type: DICOM printer Device name: DRYSTAR AXYS Manufacturer: AGFA SW Revision: R 1.60C1 Physical interface: Ethernet 10/100 Base-Tx Network protocol: TCP/IP DICOM DICOM conformance statement: Document No.: 001150 Revision 1.0 Image memory: 65 GByte Hard disk: 70 GByte Selected Variable name Setting n.a. Nickname CT hostname n.a. Use this profile only for incoming call- ing AE Title PR_hostname n.a. Use this profile only for local SCP server DEFAULT_SCP n.a. Host profile type GENERIC-GENERIC (customized) No Number of Copies 1 No Print priority Low No Polarity Normal 34 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 34 of 260 No Film orientation Portrait No Trim No No Film Size ID (empty) No Medium type (empty) n.a. Print even if Film Size ID / Medium Type is not supported No n.a. Print even if Application Type is not supported No No Initial memory size allocated per print job (Mbytes): 100 No Kernel Site, Edit Custom: Interpolation type; Cubic high res. -smoothing factor -0.7 No Magnification Magn. none No Decimate/Crop behavior: Disabled No Pixel Size ratio 1.0 / 1.0 No Perception LUT Linear n.a. Kanamori-like value 0 n.a. Custom Value empty No Illumination (cd/m) 2000 No Reflected ambient light (cd/m2) 10 No Border density (OD x 100) Black No Empty image density (OD x 100) Black No Minimum density empty No Maximum density Site 320 n.a. Header annotation Contents: Edit custom: None Courier 12 n.a. Footer annotation Contents: Edit custom: None Courier 12 n.a. Window (%) Empty n.a. Level (%) Empty Selected Variable name Setting © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 35 Page 35 of 260 Error / warning messages (examples) n.a. Image orientation r0 n.a. Conformance level 1 n.a. N-event enabled Off n.a. Mammo modality site No n.a. Association time-out(s) 0 n.a. Image time-out(s) 0 n.a. ALLOW IMPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT BIG ENDIAN Selected n.a. Resolution 508 n.a. Supported SOP classes Presentation LUT SOP class Print job SOP class Printer SOP class Basic annotation box SOP class Verification service class Basic film box SOP class Basic film session SOP class Basic color PM Meta SOP class Print Queue Management SOP INSTANCE Basic Grey Image Box SOP Class Basic color image box SOP class Basic gray PM Meta SOP class Print queue management SOP class n.a. LR like off Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Top cover open COVER OPEN COVER OPEN Camera cover, drawer or door open Tray open or front door open BAD SUPPLY MGZ BADSUPPLY MGZ Problem with supply magazine Selected Variable name Setting 36 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 36 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Send print job to camera if the camera is in service mode PRINTER OFFLINE PRINTER OFFLINE Camera offline Sent print job to cam- era with empty input tray SUPPLY EMPTY SUPPLY EMPTY Camera out of film (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 390.0 391.0 0.26 14" x 17" Landscape X 410.0 411.0 0.24 Y 320.0 320.0 0.00 14" x 14" Portrait X 330.0 331.0 0.30 Y 320.0 320.0 0.00 14" x 14" Landscape X 330.0 330.0 0.00 Y 330.0 331.0 0.30 11" x 14" Portrait X 260.0 261.0 0.38 Y 330.0 330.5 0.15 11" x 14" Landscape X 330.0 330.0 0.00 Y 250.0 251.0 0.40 10” x 12” Portrait X 230.0 230.0 0.00 Y 270.0 271.0 0.37 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 37 Page 37 of 260 10” x 12” Landscape X 280.0 280.5 0.18 Y 220.0 220.0 0.00 8" x 10" Portrait X 180.0 180.0 0.00 Y 220.0 220.0 0.00 8" x 10" Landscape X 230.0 230.0 0.00 Y 170.0 170.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 38 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 38 of 260 Agfa Drystar 5503 2.1 General information 0 Block diagram Fig. 4: Available film sizes Performance and Connections Associations Maximum number of associations supported: 10 Format Release status Film Type Medium type 14" x 17" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 14" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 11" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 10” x 12” Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 8" x 10" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 39 Page 39 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The background command does not work properly. The back- ground is always white. NOTE European EMC Classification is Class A. NOTE All four edges of the diagnostic area are cut (approx 1 mm) for 8x10, 10x12, 11x14,14x17. NOTE Typical line structure of the thermo head is visible. Known effects NOTE The built in densitometer has to be set to X-Rite 301x to achieve the required image quality. SCU / Modality Software Configuration 0 Time 70 sec Application Entity Properties Display Changes allowed AE Title DRY5503 Yes Port number 104 No 40 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 40 of 260 HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec file name) agfadrystar5503_AX YS No DICOM Node DRY5503 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 50.0 x 50.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 6922 x 8368 14" x 14" 6882 x 6882 11" x 14" 5376 x 6922 10" x 12" 4880 x 5860 8" x 10" 3852 x 4880 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 8368 x 6922 14" x 14" 6882 x 6882 11" x 14" 6922 x 5376 10" x 12" 5860 x 4880 8" x 10" 4880 x 3852 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 41 Page 41 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Background Black Yes Transformation No magnification No Filming properties Display Changes allowed Device type: DICOM printer Device name: DRYSTAR 5503 Manufacturer: AGFA SW Revision: R 5.0.0 B2 Physical Interface: Ethernet 10/100 Base-Tx Network protocol: TCP/IP DICOM DICOM Conformance Statement: AGFA Medical Imaging DICOM Conform- ance Statement, DrayStar 5503, SW ver- sion 5.0 Image memory: 2 * 256 Mbyte (RAM memory) Hard disk: min. 18 Gbyte Selected Variable name Setting n.a. Nickname CT hostname n.a. Use this profile only for incoming call- ing AE Title PR_hostname n.a. Use this profile only for local SCP server DEFAULT_SCP n.a. Host profile type GENERIC-GENERIC (customized) No Number of Copies 1 No Print priority Low 42 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 42 of 260 No Polarity Normal No Film destination output tray n.a. n.a. Tray 1 Selected n.a. Tray 2 Deselected n.a. Tray 3 Deselected n.a. Tray 4 Deselected No Film orientation Portrait No Trim No No Film Size ID (empty) No Medium type “empty” n.a. Print even if Film Size ID / Medium Type is not supported No n.a. Print even if Application Type is not supported No No Initially allocated memory size per print job (Mbytes): 100 No Kernel Site, Edit Custom: Interpolation type; Cubic high res. -smoothing factor -0.7 No Magnification Magn. none No Pixel Size ratio 1.0 / 1.0 No Perception LUT Linear n.a. Kanamori-like value 0 n.a. Custom Value “empty” No Illumination (cd/m) 2000 No Reflected ambient light (cd/m2) 10 No Border density (OD x 100) Black No Empty image density (OD x 100) Black No Minimum density “empty” No Maximum density Site 320 n.a. Header annotation Contents: Edit custom: None Courier 12 Selected Variable name Setting © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 43 Page 43 of 260 n.a. Footer annotation Contents: Edit custom: None Courier 12 n.a. Window (%) “empty” n.a. Level (%) “empty” n.a. Image orientation r0 n.a. Conformance level 1 n.a. N-event enabled Off n.a. Mammo modality site, No n.a. Association time-out(s) 0 n.a. Image time-out(s) 0 n.a. ALLOW IMPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT BIG ENDIAN Selected n.a. Resolution 508 n.a. Supported abstract syntax Presentation LUT SOP class Print job SOP class Printer SOP class Basic annotation box SOP class Verification service class Basic film box SOP class Basic film session SOP class Basic color PM Meta SOP class Print Queue Management SOP INSTANCE Basic Grey Image Box SOP Class Basic Color Image Box SOP Class Basic gray PM Meta SOP class Print queue management SOP class n.a. Early processing allowed Yes n.a. LR like off Selected Variable name Setting 44 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 44 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Open front door COVER OPEN COVER OPEN Camera cover, drawer or door open Tray open or front door open BAD SUPPLY MGZ BADSUPPLY MGZ Problem with supply magazine Sent print job to cam- era with empty input tray SUPPLY EMPTY SUPPLY EMPTY Camera out of film Camera is warming up PRINTER INIT PRINTER INIT Camera initializing (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 390.0 389.5 0.13 14" x 17" Landscape X 410.0 409.5 0.12 Y 330.0 330.0 0.00 14" x 14" Portrait X 330.0 330.0 0.00 Y 320.0 319.5 0.16 14" x 14" Landscape X 330.0 329.5 0.15 Y 330.0 330.0 0.00 11" x 14" Portrait X 250.0 250.0 0.00 Y 320.0 320.0 0.00 11" x 14" Landscape X 330.0 330.0 0.00 Y 250.0 250.0 0.00 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 45 Page 45 of 260 10” x 12” Portrait X 230.0 230.0 0.00 Y 270.0 270.0 0.00 10” x 12” Landscape X 280.0 280.0 0.00 Y 230.0 230.0 0.00 8" x 10" Portrait X 180.0 180.0 0.00 Y 230.0 230.0 0.00 8" x 10" Landscape X 230.0 230.0 0.00 Y 170.0 170.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 46 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 46 of 260 Agfa Drystar 5500 2.2 General Information 0 Block Diagram Fig. 5: Available Film Sizes Performance and Connections Associations Maximum number of associations supported: 10 Format Release status Film type Medium type 14" x 17" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 14" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 11" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 10” x 12” Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 8" x 10" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 47 Page 47 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, 4x5 format, Copies=1, default center/width, magnification type none. The optimum connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The background command does not work properly. The back- ground is always white. NOTE All four edges of the diagnostic area are cut (approx 1 mm) for 8x10, 10x12, 11x14,14x17. NOTE Typical line structure of the thermo head is visible. Known effects NOTE The built in densitometer has to be set to X-Rite 301x to achieve the required image quality. SCU / Modality Software Configuration 0 Time 69 sec Application Entity Properties Display Changes allowed AE Title DRY5500 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOM printer No 48 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 48 of 260 Class (Printer spec file name) agfadrystar5500 No DICOM Node DRY5500 Yes Filming properties Display Changes allowed Hold printed film jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 50.0 x 50.0 No Film sheet formats, Portrait Number of pixels [columns x rows] 14" x 17" 6922 x 8368 14" x 14" 6882 x 6882 11" x 14" 5376 x 6922 10" x 12" 4880 x 5860 8" x 10" 3852 x 4880 In “define new” Do not modify/add Select only Delete only Film sheet formats, Landscape Number of pixels [columns x rows] 14" x 17" 8368 x 6922 14" x 14" 6882 x 6882 11" x 14" 6922 x 5376 10" x 12" 5860 x 4880s 8" x 10" 4880 x 3852 Medium type Blue film Yes Film destination Processor No Color appearance Gray scale 8 bit No Background Black Yes Transformation No magnification No HC Device / General settings Display Changes allowed © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 49 Page 49 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer Settings Device type: DICOM printer Device name: DRYSTAR 5500 Manufacturer: AGFA SW Revision: V3.0.0 C1 Physical interface: Ethernet (RJ45) Network protocol: TCP/IP DICOM conformance statement: AGFA Medical Imaging DICOM Conform- ance Statement, DrayStar 5500, Document No.: 737 Image memory: 2 * 256 Mbyte Hard disk: 18 GByte Selected Variable name Setting n.a. Nickname CT hostname n.a. Use this profile only for incoming call- ing AE Title PR_hostname n.a. Use this profile only for local SCP server DEFAULT_SCP n.a. Host profile type GENERIC-GENERIC (customized) No Number of Copies 1 No Print priority Low No Polarity Normal No Film destination output tray n.a. n.a. Tray 1 Selected n.a. Tray 2 Deselected 50 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 50 of 260 n.a. Tray 3 Deselected n.a. Tray 4 Deselected No Film orientation Portrait No Trim No No Film Size ID (empty) No Medium type (empty) n.a. Print even if Film Size ID / Medium Type is not supported No n.a. Print even if Application Type is not supported No No Initial memory size allocated per print job (Mbytes): 100 No Kernel Site, Edit Custom: Interpolation type; Cubic high res. -smoothing factor -0.7 No Magnification Magn. none No Pixel Size ratio 1.0 / 1.0 No Perception LUT Linear n.a. Kanamori-like value 0 n.a. Custom Value “empty” No Illumination (cd/m) 2000 No Reflected ambient light (cd/m2) 10 No Border density (OD x 100) Black No Empty image density (OD x 100) Black No Minimum density “empty” No Maximum density Site 320 n.a. Header annotation Contents: Edit custom: None Courier 12 n.a. Footer annotation Contents: Edit custom: None Courier 12 n.a. Window (%) Empty Selected Variable name Setting © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 51 Page 51 of 260 n.a. Level (%) Empty n.a. Image orientation r0 n.a. Conformance level 1 n.a. N-event enabled Off n.a. Mammo modality site, No n.a. Association time-out(s) 0 n.a. Image time-out(s) 0 n.a. ALLOW IMPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT BIG ENDIAN Selected n.a. Resolution 508 n.a. Supported abstract syntax Presentation LUT SOP class Print job SOP class Printer SOP class Basic annotation box SOP class Verification service class Basic film box SOP class Basic film session SOP class Basic color PM Meta SOP class Print Queue Management SOP INSTANCE Basic Grey Image Box SOP Class Basic Color Image Box SOP Class Basic gray PM Meta SOP class Print queue management SOP class n.a. Early processing allowed Yes n.a. LR like off Selected Variable name Setting 52 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 52 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Sent print job to cam- era with front door open COVER OPEN COVER OPEN Camera cover, drawer or door open Tray open or front door open BAD SUPPLY MGZ BADSUPPLY MGZ Problem with supply magazine Sent print job to cam- era with empty input tray SUPPLY EMPTY SUPPLY EMPTY Camera out of film Printer warming up PRINTER INIT PRINTER INIT Camera initializing (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 400.0 399.0 0.25 14" x 17" Landscape X 410.0 409.0 0.24 Y 330.0 330.0 0.00 14" x 14" Portrait X 330.0 329.5 0.15 Y 330.0 330.0 0.00 14" x 14" Landscape X 330.0 330.0 0.00 Y 330.0 329.5 0.15 11" x 14" Portrait X 250.0 249.5 0.20 Y 330.0 330.0 0.00 11" x 14" Landscape X 330.0 330.0 0.00 Y 250.0 249.5 0.00 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 53 Page 53 of 260 10” x 12” Portrait X 230.0 230.0 0.00 Y 270.0 269.5 0.19 10” x 12” Landscape X 280.0 279.5 0.18 Y 230.0 230.0 0.00 8" x 10" Portrait X 180.0 179.5 0.28 Y 230.0 230.0 0.00 8" x 10" Landscape X 230.0 230.0 0.00 Y 170.0 169.5 0.29 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 54 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 54 of 260 Agfa Drystar 5302 2.3 General information 0 Block diagram Fig. 6: Available film sizes Performance and Connections Associations Maximum number of associations supported: 11 Format Release status Film type Medium type 14" x 17" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 14" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 11" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 10” x 12” Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 8" x 10" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 55 Page 55 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The background command does not work properly. The back- ground is always white. NOTE If the film size was not included in the configuration of the camera, the connection to the camera is not available. Known effects NOTE The built in densitometer has to be set to X-Rite 301x to achieve the required image quality. SCU / Modality Software Configuration 0 Time 67 sec Application Entity Properties Display Changes allowed AE Title DRY5302 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec. file name) agfadrystar5302 No DICOM Node Agfa5302 Yes 56 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 56 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes that are not available at the customer site. Filming properties Display Changes allowed Hold printed film jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 79.375 x 79.375 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4358 x 5232 14" x 14" 4358 x 4303 11" x 14" 3348 x 4358 10” x 12” 3070 x 3653 8" x 10" 2376 x 3070 In “Define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5232 x 4358 14" x 14" 4303 x 4358 11" x 14" 4358 x 3348 10” x 12” 3653 x 3070 8" x 10" 3070 x 2376 Medium type Blue film Yes Film destination Processor No Color appearance Gray scale 8 bit No Background Black Yes Transformation No magnification No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 57 Page 57 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Device type: DICOM printer Device name: DRYSTAR 5302 Manufacturer: AGFA SW Revision: V1.80 c1 Physical Interface: Ethernet (RJ45) Network protocol: TCP/IP DICOM Conformance Statement: Revision 1.1, June 2005 Image memory: 512 Mbyte (internal memory) Hard disk: 35 GB Selected Variable name Setting n.a. Nickname CT hostname n.a. Use this profile only for incoming "Calling AE Title": PR_hostname n.a. Use this profile only for local SCP server DEFAULT_SCP n.a. Host Profile Type GENERIC-GENERIC (custom- ized) No Number of Copies 1 No Print priority Low No Polarity Normal No Film orientation Portrait No Trim No No Film Size ID Deselected No Medium type Deselected n.a. Print even if Film Size ID / Medium Type is not supported No n.a. Print even if Application Type is not sup- ported: No No Initial allocated memory size per print job (Mbytes): 100 58 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 58 of 260 No Kernel SITE (*) Edit Custom: Interpolation type: Cubic high res. -smoothing factor -0.7 No Magnification Magn: Max. - custom scale fac- tor 1.0 No Pixel Size Ratio: 1.0 / 1.0 No Perception LUT Linear n.a. Kanamori-like value 0 n.a. Custom Value Deselected No Illumination (cd/m2) 2000 No Reflected ambient light (cd/m2) 10 No Border density (OD x 100) Black No Empty image density (OD x 100) Black No Minimum density Empty No Maximum density Site 300 n.a. Header annotation Contents: Edit custom: None Courier 12 n.a. Footer annotation Contents: Edit custom: None Courier 12 n.a. Window (%) Empty n.a. Level (%) Empty n.a. Image orientation R0 n.a. Conformance level 1 n.a. N-event enabled Off n.a. Mammo modality Site, No. n.a. Association time-out(s) 0 n.a. Image time-out(s) 0 n.a. ALLOW IMPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT BIG ENDIAN Selected Selected Variable name Setting © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 59 Page 59 of 260 Error / Warning Messages (examples) n.a. Resolution 320 n.a. Supported SOP classes: Edit n.a. Supported abstract syntax Presentation LUT SOP class Print job SOP class Printer SOP class Basic annotation box SOP class Verification service class Basic film box SOP class Basic film session SOP class Basic color PM Meta SOP class Print Queue Management SOP INSTANCE Basic Grey Image Box SOP Class Basic Color Image Box SOP Class Basic gray PM Meta SOP class Print queue management SOP class n.a. LR-like Off Action that results in camera error mes- sages Printer messages Message displayed on SCU Defined DCS (*1) Sent by SCP (*2) Top cover open COVER OPEN COVER OPEN Camera cover, drawer or door open Open film supply tray BAD SUPPLY MGZ BAD SUPPLY MGZ Problem with supply magazine Empty input tray SUPPLY EMPTY SUPPLY EMPTY Camera out of film Sent wrong film size n.a. n.a. Status -> aborted (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Selected Variable name Setting 60 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 60 of 260 NOTE If film size is not inserted in configuration of camera, connec- tion to camera is not available. Image Quality and Optical Density 0 No specific parameter available. Real size scaling Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 390.0 391.0 0.26 14" x 17" Landscape X 410.0 411.0 0.24 Y 330.0 330.0 0.00 14" x 14" Portrait X 330.0 331.0 0.30 Y 330.0 330.0 0.00 14" x 14" Landscape X 330.0 330.0 0.00 Y 330.0 331.0 0.30 11" x 14" Portrait X 250.0 250.5 0.20 Y 330.0 330.0 0.00 11" x 14" Landscape X 330.0 330.0 0.00 Y 250.0 251.0 0.40 10” x 12” Portrait X 230.0 230.0 0.00 Y 270.0 271.0 0.37 10” x 12” Landscape X 280.0 281.0 0.36 Y 230.0 230.0 0.00 8" x 10" Portrait X 170.0 170.5 0.29 Y 230.0 230.0 0.00 8" x 10" Landscape X 230.0 230.0 0.00 Y 170.0 170.0 0.00 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 61 Page 61 of 260 Agfa Drystar 5300 2.4 General information 0 Block diagram Fig. 7: Available film sizes Performance and Connections Associations Maximum number of associations supported: 11 Format Release status Film Type Medium type 14" x 17" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 14" x 14" Portrait n.a. N/A n.a. Landscape n.a. N/A n.a. 11" x 14" Portrait Yes DT2B Blue-based Landscape Yes DT2B Blue-based 10” x 12” Portrait n.a. N/A n.a. Landscape n.a. N/A n.a. 8" x 10" Portrait n.a. N/A n.a. Landscape n.a. N/A n.a. Other n.a. N/A n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 62 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 62 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The background command does not work properly. The back- ground is always white. Known effects NOTE The built in densitometer has to be set to X-Rite 301x to achieve the required image quality. SCU / Modality Software Configuration 0 Time 67 sec Application Entity Properties Display Changes allowed AE Title DRY5300 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec file name) agfadrystar5300 No DICOM Node DS5300 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 24 Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 63 Page 63 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Pixel Size [1/1000 mm] 79.375 x 79.375 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4256 x 5174 11" x 14" 3300 x 4256 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5174 x 4256 11" x 14" 4256 x 3300 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No Filming properties Display Changes allowed Device type: DICOM print server/printer Device name: DRYSTAR 5300 Manufacturer: AGFA SW Revision: 1.82 C1 Physical Interface: 10/100 Base - T Network protocol: TCP/IP DICOM Conformance Statement: Rev.1.2, October 24, 2005 Image memory: 512 Mbyte Hard disk: None 64 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 64 of 260 Printer settings Selected Variable name Setting n.a. Nickname CT hostname n.a. Use this profile only for incoming “Calling AE title” PR_hostname n.a. Use this profile only for local SCP server All n.a. Host Profile Type GENERIC-GENERIC (customized) No Number of Copies 1 No Print priority Low No Polarity Normal No Film orientation Portrait No Trim No No Film Size ID Deselected No Medium type Deselected n.a. Print even if Film Size ID / Medium Type is not supported No No Kernel SITE Interpolation type: Cubic High Res - Smooth Factor -2.5 No Magnification Magn: Max. - custom scale factor 1.0 No Pixel Size Ratio: 1.0 / 1.0 No Perception LUT Linear No Kanamori-like value 0 No Custom Value Deselected No Illumination (cd/m) 2000 No Reflected ambient light (cd/m2) 10 No Border density (OD x 100) Black No Empty image density (OD x 100) Black No Minimum density Empty No Maximum density Site 300 No. Annotation 1 None No Annotation 2 None © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 65 Page 65 of 260 n.a. Window (%) Empty n.a. Level (%) Empty n.a. Image orientation R0 n.a. Conformance level 1 n.a. N-event enabled Off n.a. Mammo Modality site: No. n.a. Association time-out(s) 0 n.a. Image time-out(s) 0 n.a. ALLOW IMPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT VR LITTLE ENDIAN Selected n.a. ALLOW EXPLICIT BIG ENDIAN Selected n.a. Resolution 320 n.a. Supported SOP Classes Presentation LUT SOP class Print job SOP class Printer SOP class Basic annotation box SOP class Verification service class Basic film box SOP class Basic film session SOP class Basic Color PM Meta SOP Class Print Queue Management SOP INSTANCE Basic Grey Image Box SOP Class Basic Color Image Box SOP Class Basic gray PM Meta SOP class Print queue management SOP class n.a. Initial allocated memory size per print job (MBytes) 23 Selected Variable name Setting 66 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 66 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Action that results in camera error messages Printer messages Message dis- played on SCU (*2) Defined DCS (*1) Sent by SCP Open input tray BAD SUPPLY MGZ WARNING\BAD SUPPLY MGZ Camera info.: WARNING Top cover open COVER OPEN WARNING\COVER OPEN Camera info.: WARNING Empty input tray SUPPLY EMPTY WARNING\SUPPLY EMPTY Camera info.: WARNING (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 400.0 401.0 0.25 14" x 17" Landscape X 400.0 401.5 0.37 Y 320.0 320.0 0.00 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X 250.0 250.5 0.20 Y 320.0 320.0 0.00 11" x 14" Landscape X 330.0 330.0 0.00 Y 250.0 250.5 0.20 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 67 Page 67 of 260 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 68 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 68 of 260 Agfa Drystar 3000 2.5 General information 0 Block diagram Fig. 8: Available film sizes Performance and Connections Associations Maximum number of associations supported: 4 Format Release status Film Type Medium type 14" x 17" Portrait Yes DT1B Blue-based Landscape Yes DT1B Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait No No No Landscape No No No 10” x 12” Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 69 Page 69 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The background command does not work properly. The back- ground is always white. Known effects NOTE Changing the film size requires manual modifications at the camera site. SCU / Modality Software Configuration 0 Time 160 sec Application Entity Properties Display Changes allowed AE Title DRY3000 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec file name) agfadrystar3000 No DICOM Node DRY3000 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 No 70 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 70 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Pixel Size [1/1000 mm] 79.4 x 79.4 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4224 x 4839 11" x 14" 3268 x 3924 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5142 x 3924 11" x 14" 4224 x 2962 Medium type Blue film Yes Film destination Processor Yes Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No Filming properties Display Changes allowed Device type: DICOM printer Device name: DRYSTAR 3000 Manufacturer: AGFA SW Revision: MeGa 3.32, cad 32948, ecu 32950, DI301p95, R1.95, aos 32947, dcm 32957, mps 32941, OEM 49535 Physical Interface: 10 base - TP Ethernet Network protocol: TCP/IP DICOM Conformance Statement: Rev.2.3, July 31, 2003 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 71 Page 71 of 260 Printer settings Error / Warning Messages (examples) Image memory: 32 Mbyte Hard disk: 1.2 Gbyte File Name Content Remarks pms.ini PR_hostname IDF= CFG=D:\MEDCOM2.PMS No .idf file defined PMS.IDF is the default PMS.IDF default STANDARD\1,1 Agfa layout ID: 14x17P ID1411 14x17L ID1511 14x14P ID1611 11x14P ID1211 11x14L ID1311 8x10P ID1011 8x10L ID1111 Medcom2.pms 00 pms_virgin_cfg 0 n-event_enabled 0 trim_flag 0 utl_id 1 is used (DCS), no *.idf file defined AGFA confirm Level is 0 (warnings) Disable N-events messages Disable trim around images LINEAR LUT Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Switch camera from online to offline PRINTER OFFLINE Association rejected Connection to cam- era is not available Open cover (lower) SUPPLY EMPTY SUPPLY EMPTY Camera out of film Top cover open n.a. CHECK PRINTER Check camera Supply magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality 72 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 72 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 380.0 377.5 0.66 14" x 17" Landscape X 400.0 397.0 0.75 Y 300.0 300.0 0.00 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X No No No Y No No No 11" x 14" Landscape X No No No Y No No No 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 73 Page 73 of 260 Agfa LR5200 / MG3000 2.6 General information 0 Block diagram Fig. 9: Available film sizes Format Release status Film Type Medium type 14" x 17" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape Yes Scopix LT2B DLA1 Blue-based 14" x 14" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape No No No 11" x 14" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape Yes Scopix LT2B DLA1 Blue-based 10” x 12” Portrait n.a. N/A n.a. Landscape n.a. N/A n.a. 8" x 10" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape Yes Scopix LT2B DLA1 Blue-based Other n.a. N/A n.a. Released: Yes - Film size is available and released 74 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 74 of 260 Performance and Connections Associations Maximum number of associations supported: 4 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The background command does not work properly. NOTE No message will be displayed in case of manual input of films into developer. Known effects NOTE The camera does support format 14”X14” landscape. SCU / Modality Software Configuration 0 Released: No - Film size is available but not released Released: n.a. - Film size is not available Time 228 sec Application Entity Properties Display Changes allowed AE Title LR5200 Yes Port number 104 No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 75 Page 75 of 260 HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec file name) agfalr5200 No DICOM Node LR5200 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 80.0 x 80.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4224 x 4839 14" x 14" 4224 x 3897 11" x 14" 3268 x 3924 8" x 10" 2344 x 2647 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5140 x 3924 11" x 14" 4224 x 2962 8" x 10" 2948 x 2046 Medium type Blue film Yes Film destination Processor Yes Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No 76 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 76 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Device type: DICOM print server/printer Device name: MG 3000 Manufacturer: AGFA SW Revision: MeGa 3.32, dcm 32957 Physical Interface: 10 base - TP Ethernet Network protocol: TCP/IP DICOM Conformance Statement: Rev.1.4, April 20, 2001 Image memory: 128 Mbyte Hard disk: 4.1 Gbyte Device type: DICOM camera Device name: LR 5200 Manufacturer: AGFA SW Revision: LTP 01806, 240698 Physical Interface: FOI optic Network protocol: None DICOM Conformance Statement: None Image memory: n.a. Hard disk: None © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 77 Page 77 of 260 Printer settings Error / Warning Messages (examples) File Name Content Remarks pms.ini PR_hostname IDF= CFG=D:\MEDCOM2.PMS No .idf file defined PMS.IDF is the default PMS.IDF default STANDARD\1,1 Agfa layout ID: 14x17P ID1411 14x17L ID1511 14x14P ID1611 11x14P ID1211 11x14L ID1311 8x10P ID1011 8x10L ID1111 Medcom2.pms 00 pms_virgin_cfg 0 n-event_enabled 0 trim_flag 0 utl_id 1 is used (DCS), no *.idf file defined AGFA default confirm Level is 0 (warnings) Disable N-events messages Disable trim around images LINEAR LUT Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Camera switched off or camera switched to offline OFFLINE OFFLINE Camera is switched off-line Manual input of films in developer NORMAL NORMAL No message dis- played Camera is switched on PRINTER INIT PRINTER INIT Camera is warming up Supply magazine empty NO SUPPLY MGZ NO SUPPLY MGZ Film supply not avail- able (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality 78 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 78 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 331.5 0.45 Y 380.0 383.0 0.79 14" x 17" Landscape X 400.0 403.0 0.75 Y 300.0 301.0 0.33 14" x 14" Portrait X 330.0 332.0 0.61 Y 300.0 302.0 0.67 14" x 14" Landscape X No No No Y No No No 11" x 14" Portrait X 250.0 252.0 0.80 Y 300.0 301.0 0.33 11" x 14" Landscape X 330.0 331.5 0.45 Y 220.0 221.5 0.68 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X 170.0 170.5 0.29 Y 200.0 201.5 0.75 8" x 10" Landscape X 230.0 232.0 0.87 Y 160.0 160.5 0.31 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 79 Page 79 of 260 Agfa LR5200 / LR DICOM Controller 2.7 General information 0 Block diagram Fig. 10: Available film sizes Format Release status Film Type Medium type 14" x 17" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape Yes Scopix LT2B DLA1 Blue-based 14" x 14" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape No No No 11" x 14" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape Yes Scopix LT2B DLA1 Blue-based 10” x 12” Portrait n.a. N/A n.a. Landscape n.a. N/A n.a. 8" x 10" Portrait Yes Scopix LT2B DLA1 Blue-based Landscape Yes Scopix LT2B DLA1 Blue-based Other n.a. N/A n.a. Released: Yes - Film size is available and released 80 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 80 of 260 Performance and Connections Associations Maximum number of associations supported: 15 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). Known effects NOTE For page mode magnification, set type "NONE" and activate the mark. NOTE The camera does support format 14”X14” landscape. SCU / Modality Software Configuration 0 Released: No - Film size is available but not released Released: n.a. - Film size is not available Time 197 sec Application Entity Properties Display Changes allowed AE Title LRDICOM Yes Port number 104 No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 81 Page 81 of 260 HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec file name) agfalr5200 No DICOM Node LR5200 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 80.0 x 80.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4224 x 4839 14" x 14" 4224 x 3897 11" x 14" 3268 x 3924 8" x 10" 2344 x 2647 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5140 x 3924 11" x 14" 4224 x 2962 8" x 10" 2948 x 2046 Medium type Blue film Yes Film destination Processor Yes Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No 82 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 82 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Device type: DICOM print server/printer Device name: Agfa LR DICOM Controller Manufacturer: AGFA SW Revision: FLC1.01.14 Physical Interface: Gateway Network protocol: TCP/IP DICOM Conformance Statement: Rev. 1.2, July 31, 2003 Image memory: 128 MB RAM Hard disk: 20 Gbyte Device type: DICOM camera Device name: LR 5200 Manufacturer: AGFA SW Revision: LTP 01806.240698 Physical Interface: FOI optic Network protocol: None DICOM Conformance Statement: None Image memory: n.a. Hard disk: None Selected Variable name Setting n.a. Calling AE title PR_Hostname n.a. Nickname CT hostname © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 83 Page 83 of 260 n.a. Host profile type GENERIC-GENERIC (customized) No Number of Copies 1 No Print priority Low No Polarity Normal No Film orientation Portrait No Trim No No Film Size ID Deselected No Medium type Deselected n.a. Print even if Film Size ID / Medium Type is not supported No No Kernel Site Magnification type: cubicHighRes Smooth Factor: - 0.7 Yes Magnification Type: None Max Custom scale factor: 1.0 No Pixel Size Ratio: 1.0 / 1.0 No Perception LUT Linear No Kanamori-like value 0 No Custom Value Deselected No Illumination (cd/m) 2000 No Reflected ambient light (cd/m2) 10 No Border density (OD x 100) Black No Empty image density (OD x 100) Black No Minimum density Empty No Maximum density Site 320 n.a. Header annotation No Content: Edit custom: none Courier 12 n.a. Footer annotation No Content: Edit custom: none Courier 12 Selected Variable name Setting 84 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 84 of 260 n.a. Window (%) Empty n.a. Level (%) Empty n.a. Image orientation r0 n.a. Conformance level 1 n.a. N-event enabled Off n.a. Mammo Site no. n.a. Association time-out(s) 0 n.a. Image time-out(s) 0 n.a. ALLOW IMPLICIT VR LITTLE ENDIAN Yes n.a. ALLOW EXPLICIT VR LIT- TLE ENDIAN Yes n.a. ALLOW EXPLICIT BIG ENDIAN Yes n.a. Resolution 315 n.a. Supported abstract syntax Basic Film Box_SOP_Class Basic gray PM Meta_SOP_Class Print Queue Management_SOP_INSTANCE Printer_SOP_Class Basic Color Image Box_SOP_CLass Basic Grey Image_Box_SOP_Class Basic Film Session_SOP_Class Print Job_SOP_Class Presentation LUT_SOP_Class Basic Annotation Bo_ SOP_Class Verification service class Print Queue Management_SOP_Class Selected Variable name Setting © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Agfa 85 Page 85 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Action that results in camera error mes- sages Printer messages Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Camera switched off or Camera switched to offline PRINTER OFFLINE PRINTER OFFLINE Camera offline Camera start-up PRINTER INIT PRINTER INIT Camera initializing Manual input of film in developer CHECK PRINTER CHECK PRINTER Check camera (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 331.5 0.45 Y 370.0 373.0 0.81 14" x 17" Landscape X 400.0 403.0 0.75 Y 300.0 301.5 0.50 14" x 14" Portrait X 330.0 331.0 0.30 Y 330.0 332.5 0.76 14" x 14" Landscape X No No No Y No No No 11" x 14" Portrait X 250.0 252.0 0.80 Y 300.0 301.0 0.33 11" x 14" Landscape X 330.0 331.0 0.30 Y 220.0 221.5 0.68 86 Specific Camera Information - Agfa SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 86 of 260 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X 170.0 170.0 0.00 Y 200.0 201.5 0.75 8" x 10" Landscape X 230.0 231.5 0.65 Y 160.0 160.5 0.31 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Codonics 87 Page 87 of 260 3- 3Specific Camera Information - Codonics Codonics Horizon 0 General information 0 Block diagram Fig. 11: Available film sizes Format Release status Film Type Medium type 14" x 17" Portrait Yes DirectVista Grayscale Blue-based Landscape Yes DirectVista Grayscale Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait No No No Landscape No No No 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait Yes DirectVista Grayscale Blue-based Landscape Yes DirectVista Grayscale Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released 88 Specific Camera Information - Codonics SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 88 of 260 Performance and Connections Associations Maximum number of associations supported: More than 30 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The background command does not work properly. The back- ground is always white. NOTE Film size 8” x 10” is not released for subdivision 1x1 with lin- ear LUT. Film size 8” x 10” is not released also for subdivisions smaller than 6 on 1 (4 on 1; 2 on 1; etc) with CT LUT. NOTE Print-outs on paper are not released. Known Effects n/a SCU / Modality Software Configuration 0 Released: No - Film size is available but not released Released: n.a. - Film size is not available Time 95 sec. Application Entity Properties Display Changes allowed AE Title HORIZON Yes Port number 104 No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Codonics 89 Page 89 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) codonicshorizon No DICOM Node Horizon Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 79.4 x 79.4 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4322 x 5025 11" x 14" 3382 x 4022 8" x 10" 2406 x 2790 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5025 x 4322 11" x 14" 4022 x 3382 8" x 10" 2790 x 2406 Medium type Blue film Yes Film destination Processor Yes Color appearance Grayscale 8 bit No Background Black No Transformation No magnification No 90 Specific Camera Information - Codonics SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 90 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Manufacturer / device type: DICOM Printer (SCP) Device name: Horizon Manufacturer: Codonics SW Revision: V 1.9.0 Physical type: Ethernet 10/100 base T/Tx Network protocol: TCP/IP DICOM Conformance Statement: D.C.S., V1.9.0 Image memory: 256 MB RAM, 6 GB-HD Hard disk: 10 GB Content: DV FILM BLUE Gamma: Contrast: Dmax: Dmin: Film View: Illumination: Reflected Light: LUT: Polarity: Background: Scaling: Rotate: Image Warnings: Captions: Border Fill: Crop Anchor: Scale Factor: Coverage: 1.0 0 300 0 Front 2000 10 linear Positive Black Bilinear Auto On Off On Center 0.0 Standard © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Codonics 91 Page 91 of 260 Error / Warning Messages (examples) Step in Service Mode (with "<" and "Menu") select Job Settings Select: PR_hostname (AE title of modality) Name: Media Receive Tray: Priority: Gamma: Contrast: Dmax: Dmin: Film View: Illumination: Reflected Light: LUT: Polarity: Saturation: MCM: Background: Scaling: Rotate: Image Warnings: Captions: Border Fill: Crop Anchor: Scale Factor: Coverage: PR_hostname DV FILM BLUE 14X17 Default Default 1.0 0 Default Default Front Default Default linear Positive Default Default Black Bilinear Auto On Off On Center Default Standard Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Printer switched to service mode PRINTER OFFLINE PRINTER OFFLINE Printer offline Top cover open COVER OPEN COVER OPEN Camera cover, drawer or door open Content: 92 Specific Camera Information - Codonics SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 92 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Supply magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film Send job when no magazine is inserted EMPTY 14X17 BLUE EMPTY 14X17 BLUE 14”x17” blue film sup- ply empty (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.5 0.15 Y 380.0 380.5 0.13 14" x 17" Landscape X 390.0 390.5 0.13 Y 330.0 330.5 0.15 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Codonics 93 Page 93 of 260 8" x 10" Portrait X 170.0 170.0 0.00 Y 210.0 210.5 0.24 8" x 10" Landscape X 200.0 200.0 0.00 Y 170.0 170.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 94 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 94 of 260 4- 4Specific Camera Information - Fuji Fuji Drypix 7000 / 5000 0 General information 0 Block diagram Fig. 12: Available film sizes Performance and Connections Associations Maximum number of associations supported: 10 Format Release status Film Type Medium type 14" x 17" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based 14" x 14" Portrait Yes DI-HL Blue-based Landscape n.a. n.a. n.a. 11" x 14" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based 10" x 12" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based 8" x 10" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 95 Page 95 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Device is only class A, EN55011(Hospital use). NOTE 14INX14IN landscape not supported by camera. NOTE Film job that contains more than 10 films will not be printed out completely. (with SW-Revision 13.0-0001 only) Known Effects n.a. SCU / Modality Software Configuration 0 Time 66 sec. Application Entity Properties Display Changes allowed AE Title DRY7000 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) fujidrypix7000 No DICOM Node dry7000 Yes 96 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 96 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 100.0 x 100.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 3500 x 4170 14" x 14" 3500 x 3410 11" x 14" 2500 x 3495 10” x 12” 2460 x 2916 8" x 10" 1954 x 2410 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 4220 x 3360 11" x 14" 3600 x 2450 10” x 12” 2972 x 2404 8" x 10" 2466 x 1898 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 97 Page 97 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Device type: DICOM Printer (SCP) Device name: Drypix 7000 Manufacturer: FUJI SW Revision: V 13.0-0001 (for VA20) V 13.5 (for VA26) Physical type: Ethernet, 10/100 base T/Tx, RJ45 Network protocol: TCP/IP DICOM Conformance Statement: September 2003, 1st Edition. Image memory: 512 MB RAM (standard) Hard disk: 20 GB File Name Content Remarks Protocol: Client: PR_hostname 0107H warning Indicate 0116H warning Indicate B604H warning Indicate N-event report RQ Disabled Use Extention format: 0: No ID Use default annotation: 0: No Change film: 272:0110H[F] Use System Timeout: 1:Yes Presentation LUT 0:No Precode picking up: 0:No Use Max/Min Density 1:Modality Logging Client: 0:No Reprint: 0:No Magnify: 98 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 98 of 260 Procedure SSM Default Smoothing Type SHARP Adjustment Param. SHARP Edge Detection 1:on (dimmed) Detection level 600 (dimmed) Sharpness 130 (dimmed) Char. Mode White (dimmed) Adjustment param. MEDIUM Edge Detection 1:On (dimmed) Detection level 600 (dimmed) Sharpness 80 (dimmed) Char. Mode 0:White (dimmed) Adjustment param. SMOOTH Edge Detection 1:On (dimmed) Detection level 800 (dimmed) Sharpness 30 (dimmed) Char. Mode 0:White (dimmed) Default Requested Decimate Crop Behavior: 1:Decimate LUT: Procedure SAR Default LUT 1 LUT 1 r table number 17 Max. density 300 Min. density 0 Contrast 100 (dimmed) Number of tuning points 0 Dmax3.6 0:Standard Output format: Border density 300 File Name Content Remarks © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 99 Page 99 of 260 Error / Warning Messages (examples) Trim density 0 Trim 0:Off Number of Copies 1 Margin between images 20 Image layout 0:Concentration Film size 4:14 IN X 17 IN Medium Type (base color): 1:Blue Film orientation 1:Portrait Mirror 0:Off Film Destination: Upper Tray: 1:use Annotation Annotation Height: 1:1 Annotation System:System Annotation 14:14 Upper Left Upper Center Upper Right Lower Left Lower Center Lower Right Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Front cover open COVER OPEN COVER OPEN Camera cover, drawer or door open Camera in utility mode PRINTER OFFLINE PRINTER OFFLINE Camera offline Camera in service mode (M-utility mode) TCP/IP INIT ERROR TCP/IP INIT ERROR Connection to cam- era is not available File Name Content Remarks 100 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 100 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Supply magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.5 0.15 Y 400.0 399.0 0.25 14" x 17" Landscape X 410.0 409.0 0.24 Y 320.0 320.5 0.16 14" x 14" Portrait X 330.0 330.5 0.15 Y 330.0 329.0 0.30 14" x 14" Landscape X No No No Y No No No 11" x 14" Portrait X 230.0 230.0 0.00 Y 340.0 340.5 0.15 11" x 14" Landscape X 350.0 350.0 0.00 Y 230.0 230.0 0.00 10” x 12” Portrait X 230.0 230.0 0.00 Y 280.0 280.5 0.18 10” x 12” Landscape X 290.0 290.0 0.00 Y 230.0 230.0 0.00 8" x 10" Portrait X 190.0 190.0 0.00 Y 230.0 229.5 0.22 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 101 Page 101 of 260 8" x 10" Landscape X 230.0 230.0 0.00 Y 170.0 170.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 102 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 102 of 260 Fuji Drypix 4000 4.1 General information 0 Block diagram Fig. 13: Available film sizes Performance and Connections Associations Maximum number of associations supported: 10 Format Release status Film type Medium type 14" x 17" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based 14" x 14" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based 11" x 14" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based 10" x 12" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based 8" x 10" Portrait Yes DI-HL Blue-based Landscape Yes DI-HL Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 103 Page 103 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE CISPR11 is Class A only (hospital use). Known Effects n.a. SCU / Modality Software Configuration 0 Time 80 sec Application Entity Properties Display Changes allowed AE Title DRY4000 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec. file name) fujidrypix4000 No DICOM Node dry4000 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 100.0 x 100.0 No 104 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 104 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes that are not available at the customer site. Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 3500 x 4170 14" x 14" 3500 x 3410 11" x 14" 2510 x 3500 10" x 12" 2460 x 2916 8" x 10" 1954 x 2410 In “Define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 4220 x 3400 14" x 14" 3500 x 3410 11" x 14" 3600 x 2460 10" x 12" 2972 x 2404 8" x 10" 2466 x 1898 Medium type Blue film Yes Film destination Processor No Color appearance Gray scale 8 bit No Background Black Yes Transformation No magnification No Filming properties Display Changes allowed © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 105 Page 105 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Device type: DICOM Printer (SCP) Device name: Drypix 4000 Manufacturer: FUJI SW Revision: V 3.0 (for VA20) V 3.5 (for VA26) Physical type: Ethernet, (RJ45) Network protocol: TCP/IP DICOM Conformance Statement: 1st Edition, October 2004 Image memory: 512 MB RAM Hard disk: 40 GB (25 GB for image storage) File Name Content / Remarks Fuji printer PR_hostname Protocol: Attribute List Error (0107H warning) 1:Indicate Attribute Value Out of Range (0116H warning) 1:Indicate Image size is larger than image box (B604H warning) 1:Indicate N-event report RQ 0:Disabled Use extension format 0:No Use extension format --> ID (empty) Use extension format--> Use Default Annotation 0:No Change film 272:0110H[F] Use System Timeout 1:Yes Presentation LUT 0:No Precede Picking up 1:Yes Use Max/Min Density 1:Modality Logging Client 0:No Reprint 0:No Change Base Color (Disable:110H[F]) 1:Enable 106 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 106 of 260 Define Film Size of 11" x 14'' 1: 25.7 x 36.4 cm Magnify: Procedure 0:A-VR Default Smoothing Type 4:modality Adjustment Parameter -> SHARP -> Edge Detection 1:On Adjustment Parameter -> SHARP -> Detection level 600 Adjustment Parameter -> SHARP -> Sharpness 130 Adjustment Parameter -> SHARP -> Character Color 0:White Adjustment Parameter -> MEDIUM -> Edge Detection 1:On Adjustment Parameter -> MEDIUM -> Detection level 600 Adjustment Parameter -> MEDIUM -> Sharpness 80 Adjustment Parameter -> MEDIUM -> Character Color 0:White Adjustment Parameter -> SMOOTH -> Edge Detection 1:On Adjustment Parameter -> SMOOTH -> Detection level 800 Adjustment Parameter -> SMOOTH -> Sharpness 30 Adjustment Parameter -> SMOOTH -> Character Color 0:White Default Requested Decimate / Crop Behavior 1:DECIMATE Magnification Type 2:modality Requested Image Size (0=None) 0 Requested Image Size (0=None) ' Default Requested Image Size 1:modality LUT: Procedure 0:SAR Default LUT 1 Default LUT -> Configuration Information (Default LUT#) 0:printer Adjustment Parameter -> LUT1 -> r table number 17 Adjustment Parameter -> LUT1 -> Max. Density 300 Adjustment Parameter -> LUT1 -> Min. Density 20 Adjustment Parameter -> LUT1 -> 100 File Name Content / Remarks Fuji printer PR_hostname © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 107 Page 107 of 260 Adjustment Parameter -> LUT1 -> Number of tuning points 0 Dmax 3.6 0:Standard Illumination 2000 Illumination -> Default Illumination 1:modality Reflective Ambient Light 10 Reflective Ambient Light -> Default Ambient Light 1:modality Output format: Border density 280 Border density -> Default border density 1:modality Polarity (Pos./Neg.) 1:normal (Pos.) Trim density 0 Trim 0:Off Trim Width 1 Number of Copies 1 Number of Copies -> Default Number of Copies 1:modality Margin between images 20 Image layout 0:Concentration Default film size 1:modality Default Film Size -> Film Size 4: 14 IN X 17 IN Default Medium Type 0:printer Default Medium Type -> Medium Type (base color) 1: blue Film orientation 3:modality Mirror 0:OFF (Normal) Processing Type 0:Standard Print priority 1:HIGH Resolution 0:Standard Default film destination 0:printer Processsor 1: use File Name Content / Remarks Fuji printer PR_hostname 108 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 108 of 260 Error / Warning Messages (examples) Bin No 1 0: not use Bin No 2 0: not use Bin No 3 0: not used Bin No 4 0: not used Annota- tion Annotation Height 5:modality Annotation Font System:System Annotation Size 14:14 Upper Left (empty) Upper Center (empty) Upper Right (empty) Lower Left (empty) Lower Center (empty) Lower Right (empty) Camera warning or error messages Printer message Message displayed on SCU Defined DCS (*1) Sent by SCP (*2) Camera in utility mode PRINTER OFFLINE PRINTER OFFLINE Camera offline Camera in service mode (M-utility mode) TCP/IP INIT ERROR TCP/IP INIT ERROR Connection to cam- era is not available Front door open COVER OPEN COVER OPEN Camera cover, drawer or door open Supply magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality File Name Content / Remarks Fuji printer PR_hostname © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 109 Page 109 of 260 Image Quality and Optical Density 0 No specific parameter available. Real size scaling Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 332.0 0.61 Y 400.0 402.5 0.63 14" x 17" Landscape X 410.0 413.0 0.73 Y 330.0 332.5 0.61 14" x 14" Portrait X 330.0 332.5 0.76 Y 330.0 332.5 0.76 14" x 14" Landscape X 330.0 332.0 0.61 Y 330.0 332.5 0.76 11" x 14" Portrait X 230.0 232.0 0.87 Y 340.0 342.0 0.59 11" x 14" Landscape X 350.0 351.5 0.43 Y 230.0 232.0 0.87 10” x 12” Portrait X 230.0 232.0 0.87 Y 280.0 281.5 0.54 10” x 12” Landscape X 290.0 291.5 0.52 Y 230.0 232.0 0.87 8" x 10" Portrait X 190.0 191.0 0.53 Y 230.0 232.0 0.87 8" x 10" Landscape X 230.0 232.0 0.87 Y 170.0 171.0 0.59 110 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 110 of 260 Fuji Drypix 3000 4.2 General information 0 Block diagram Fig. 14: Available film sizes Performance and Connections Associations Maximum number of associations supported: 6 Format Release status Film Type Medium type 14" x 17" Portrait Yes DI-AT Blue-based Landscape Yes DI-AT Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 111 Page 111 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The DI-AT film type requires a specific densitometer charac- teristic. Density measurements using the X-Rite 301 densito- meter are only possible if the FUJI/X-Rite color compensating filter kit CM500 is installed on the X-Rite 301 and calibrated as described in the X-Rite letter. NOTE Additional annotation and trim have been switched off. NOTE The background command does not work properly. The back- ground is always white. Known Effects n.a. SCU / Modality Software Configuration 0 Time 150 sec Application Entity Properties Display Changes allowed AE Title DRYPIX3000 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOMprinter No 112 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 112 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Class (Printer spec file name) fujidrypix3000 No DICOM Node drypix3000 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 84.7 x 84.7 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4072 x 4891 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 4972 x 3993 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No HC Device / General settings Display Changes allowed Device type: DICOM Printer (SCP) Device name: Drypix 3000 Manufacturer: FUJI SW Revision: A03 Main Unit / A04 LAN Board Physical type: 100Base-Tx /10 Base T © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 113 Page 113 of 260 Printer settings Network protocol: TCP/IP DICOM Conformance Statement: 1st Edition March 31, 2001. Image memory: Approx. 56 MB Hard disk: None File Name Content Remarks None FUJI PRINTER Provided by FUJI Function Properties Protocol information Protocol = DICOM Normal AE title = DRYPIX 3000 Role = SCP Port no. = 104 Data transfer time-out = 300 Annotation Annotation size = 1:half Association count 6 Logging DICOM 0 : None Log Auto Save 0 : No Default client 0 : No Printer Model = DRYPIX Manufacturer = FUJI PHOTO FILM CO, LTD CT hostname None Protocol: Attribute list error (0107H warning) = indicate Attribute value out of range (0116H warning) = indicate Image size larger than image box (B604H warning) = 1: Indicate N-Event-Report-RQ = 0 disable Change film size = 0: 0116H ()W Use system time-out = 1: Yes Use extension format Use default annotation = 1: No Device type: DICOM Printer (SCP) 114 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 114 of 260 Error / Warning Messages (examples) Magnify: Procedure = 1:SSM Default smoothing type = 1:SHARP LUT: Procedure = 0: SAR Default LUT = 1 r table no. = 17 Max. density = 300 Min. density = 0 Output format: Border density = 300 Polarity (Pos/Neg) = 1 : normal(Pos.) Trim density = 0 Trim = 0: Off Trim with = 1 Number of copies = 1 Margin between images = 20 Image layout = 0: Concentration Film size = 1: 35x43 (14 in. x17 in.) Medium type (base color) = 1 blue Film orientation = 1: PORTRAIT Mirror = 0: OFF(Normal) Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Top cover open n/a UNKNOWN Unspecified problem with camera. Remove tray n/a UNKNOWN Unspecified problem with camera. Supply magazine empty n.a. SUPPLY EMPTY Camera out of film (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality File Name Content Remarks None FUJI PRINTER Provided by FUJI © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 115 Page 115 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 400.0 398.0 0.50 14" x 17" Landscape X 410.0 408.5 0.37 Y 320.0 320.0 0.00 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 116 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 116 of 260 Fuji Drypix 2000 4.3 General Information 0 Block Diagram Fig. 15: Available Film Sizes Performance and Connections Associations Maximum number of associations supported: 11 Format Release status Film type Medium type 14" x 17" Portrait Yes DI-HT Blue-based Landscape Yes DI-HT Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait Yes DI-HT Blue-based Landscape Yes DI-HT Blue-based 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait Yes DI-HT Blue-based Landscape Yes DI-HT Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 117 Page 117 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, 4x5 format, Copies=1, default center/width, magnification type none. The optimum connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Test of line structure and artifacts not passed. Small horizon- tal and vertical line structure visible in technical images and for all film sizes. NOTE Electro Magnetic Compatibility(EN55011, CISPR 11) classifi- cation is not available. An installation is suggested only for Industrial Areas (Hospital). Known Effects NOTE The measured values of the X-Rite 301 Densitometer must be translated via the Fuji Conversion Table (Operating Manual). NOTE Sporadic transportation problems with film size 8x10 and 11x14. Install magazine at the top side to prevent this prob- lem. SCU / Modality Software Configuration 0 Time 118 sec Application Entity Properties Display Changes allowed AE Title DP2000 Yes Port number 104 No 118 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 118 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes that are not available at the customer site. HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec. file name) fujidrypix2000 No DICOM Node DRY2000 Yes Filming properties Display Changes allowed Hold printed film jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 84.7 x 84.7 No Film sheet formats, Portrait Number of pixels [columns x rows] 14" x 17" 4107 x 4858 11" x 14" 2938 x 4094 8" x 10" 2280 x 2812 In “Define new” Do not modify/add Select only Delete only Film sheet formats, Landscape Number of pixels [columns x rows] 14" x 17" 4932 x 4016 11" x 14" 4188 x 2872 8" x 10" 2876 x 2215 Medium type Blue film Yes Film destination Processor No Color appearance Gray scale 8 bit No Background Black Yes Transformation No magnification No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 119 Page 119 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer Settings Device type: DICOM Printer (SCP) Device name: Drypix 2000 Manufacturer: FUJI SW Revision: V2.0 Physical type: Ethernet 10/100 Base T/Tx Network protocol: TCP/IP DICOM conformance statement: 1st Edition, June 2006 Image memory: 256 MB RAM Hard disk: None Fuji printer Content Protocol: Attribute List Error (0107H warning) Indicate N-event report RQ Disabled Attribute Value Out of Range (0116H warning) Indicate Image size is larger than image box (B604H warning) Indicate Change film size 272:0110H[F] Use System Timeout Yes Presentation LUT No Precede picking up No Use max/min density Modality Use extension format --> ID SM Use extension format--> Use Default Annotation No Change base color (disable:110H[F]) Enable Define Film Size of 11" x 14'' 25.7 x 36.4 cm AE Title PR_hostname Magnify: Default Smoothing Type sharp Default requested decimate / crop behavior decimate 120 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 120 of 260 Magnification Type cubic Requested image size (0=None) 0 Default Magnification Type Modality Default Smoothing Type Modality Default Requested Image Size (0=None) Modality Default requested decimate / crop behavior Modality AE Title PR_hostname Procedure AV-R SHARP -> Edge Detection On SHARP -> Detection level 600 SHARP -> Sharpness 130 SHARP -> Character Color White SMOOTH -> Edge Detection On SMOOTH -> Detection level 800 SMOOTH -> Sharpness 30 SMOOTH -> Character Color White MEDIUM -> Edge Detection On MEDIUM -> Detection level 600 MEDIUM -> Sharpness 80 MEDIUM -> Character Color White LUT Com- mon: Default LUT 1 Illumination 2000 Ambient light 10 Default LUT -> Configuration Information (Default LUT#) printer Default Illumination Modality Default Ambient Light Modality AE Title PR_hostname Procedure SAR LUT1 -> Max. Density 280 Fuji printer Content © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 121 Page 121 of 260 LUT1 -> Min. Density 18 AE Title PR_hostname LUT1 -> r table number 17 LUT1 -> Contrast 100 Number of tuning points 0 P1_Density 120 P2_Density 120 P3_Density 120 P4_Density 120 P5_Density 120 P1_Shift 0 P2_Shift 0 P3_Shift 0 P4_Shift 0 P5_Shift 0 P1_Contrast 100 P2_Contrast 100 P3_Contrast 100 P4_Contrast 100 P5_Contrast 100 Output format: AE Title PR_hostname Film Size 14INx17IN Medium type blue Film orientation portrait Border density 280 Polarity (Pos./Neg.) normal(Pos.) Trim Off Trim Width 1 Trim density 0 Fuji printer Content 122 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 122 of 260 Number of Copies 1 Print priority high Default Number of Copies Modality Default Print Priority Printer Default Medium Type Printer Default Film Orientation Modality Default Film Size Modality Default Border Density Printer Default Trim printer Default Polarity Modality AE Title PR_hostname Mirror OFF(Normal) Margin between images 20 Image layout Concentration Processing Type 2 Image Crop UPDWN Area (8x10) for CR Image both Image Crop Side Area (8x10) for CR Image both Image Crop UPDWN Area (10x14) for CR Image both Image Crop Side Area (10x14) for CR Image both Image Crop UPDWN Area (14x17) for CR Image both Image Crop UPDWN Area (10x12) for CR Image both Image Crop Side Area (10x12) for CR Image both Annotation Upper left empty Upper center empty Upper right empty Lower left empty Lower center empty Lower right empty Fuji printer Content © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 123 Page 123 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available. Real size scaling Camera warning or error messages Printer message Message displayed on SCU Defined DCS (*1) Sent by SCP (*2) Top cover open COVER OPEN COVER OPEN Camera cover, drawer or door open Remove Tray COVER OPEN COVER OPEN Camera cover, drawer or door open Supply empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film Film jam FILM JAM FILM JAM Film jam (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 400.0 398.0 0.50 14" x 17" Landscape X 410.0 407.5 0.61 Y 330.0 330.0 0.00 14" x 14" Portrait X n/a n/a n/a Y n/a n/a n/a 14" x 14" Landscape X n/a n/a n/a Y n/a n/a n/a 11" x 14" Portrait X 230.0 229.5 0.22 Y 340.0 340.0 0.00 11" x 14" Landscape X 350.0 350.0 0.00 Y 230.0 229.5 0.22 124 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 124 of 260 10” x 12” Portrait X n/a n/a n/a Y n/a n/a n/a 10” x 12” Landscape X n/a n/a n/a Y n/a n/a n/a 8" x 10" Portrait X 190.0 189.5 0.26 Y 230.0 230.0 0.00 8" x 10" Landscape X 230.0 230.0 0.00 Y 170.0 170.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 125 Page 125 of 260 Fuji FM DPL/FN-PS551 4.4 General information 0 Block diagram Fig. 16: Available film sizes Performance and Connections Associations Maximum number of associations supported: 6 Format Release status Film Type Medium type 14" x 17" Portrait Yes DI-AL Blue-based Landscape Yes DI-AL Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait Yes DI-AL Blue-based Landscape Yes DI-AL Blue-based 8" x 10" Portrait Yes DI-AL Blue-based Landscape Yes DI-AL Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 126 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 126 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE 2 cameras (each with a separate channel) can be connected to PS551. Only one camera connection to FN-PS551 was used for the qualification. NOTE The European Standard EN55011 is supported only with Class A (Hospital use). Known Effects NOTE In a multi-modality environment one additional hardware channel must be installed at FM-DPL and a second print server PS551 has to be connected for Mammography Modal- ities. NOTE When the Laser Imager connected to the print server is in the offline status being disabled to receive image data, FAILURE will be returned. SCU / Modality Software Configuration 0 Time 158 sec Application Entity Properties Display Changes allowed AE Title FMDPL Yes Port number 104 No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 127 Page 127 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. HC Device / General settings Display Changes allowed Type DICOMprinter No Class (Printer spec file name) fujifmdpl No DICOM Node FMDPL Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 100 x 100 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 3500 x 4170 11" x 14" 2538 x 3522 8" x 10" 1952 x 2410 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 4240 x 3442 11" x 14" 3600 x 2460 8" x 10" 2464 x 1898 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No 128 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 128 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Device type: DICOM print server/printer Device name: FN-PS551 Manufacturer: FUJI Photo Film SW Revision: A 07 Physical Interface: 100/10 base T Ethernet, UTP/STP Network protocol: TCP/IP DICOM Conformance Statement: FN-PS551 May 2001, 4th edition Image memory: 261.56 MB Hard disk: 3 Gbyte Device type: DICOM camera Device name: FM - DPL Manufacturer: FUJI Photo Film SW Revision: W01-02 (Main Unit) Panel: Unit W00-00 Physical Interface: SCSI Interface Network protocol: None DICOM Conformance Statement: None Image memory: 96 MB Hard disk: None Film size 14 IN X 17 IN Image type: Select: Standard scan Gradation type: Select: 3.0 File Name Content Remarks None FUJI service utility setting Provided by FUJI Function Properties © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 129 Page 129 of 260 Protocols: DICOM Properties Network port no. = 104 Data transfer time-out = 600 sec. Number of associations = 6 Association establishment restriction by the memory = enable Print server application entity = one to each printer Data receive if the printer is offline = enable Printer FMDPL Properties Name: AE title of DICOM = FMDPL Fine-printing = off Interface: Interface = E-i/f Pixel clock = 1.0 microsec/pixel Version = type 1 Film size = 14 x 17 (dimmed) Film medium = blue (dimmed) Model: Model = FN-PS551 Manufacturer = FUJI PHOTO FILM CO, LTD Clients: DICOM: CT hostname Properties Name: Hostname = CT hostname IP address = (from system administrator) File Name Content Remarks None FUJI service utility setting Provided by FUJI 130 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 130 of 260 Protocol: Protocol = DICOM Application Entity Title = PR_hostname Attribute list error (0107H warning) = indi- cate Attribute value out of range (0116H warn- ing) = indicate Image size larger than image box (B604H warning) = indicate N-event report RQ = disabled Use presentation LUT = No Data transfer time-out = enabled Use extension format = No Magnify: Procedure = SSM Default smoothing type = SHARP LUT: Procedure = SAR Default LUT = 1 (linear) Adj. parameter LUT = 1 r table no. = 17 Max. density = 300 Min. density = 0 Number of tuning points = 0 Printer: fixed, FMDPL File Name Content Remarks None FUJI service utility setting Provided by FUJI © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 131 Page 131 of 260 Output format 1: Border density = 300 Polarity = normal(Pos.) Trim density = 0 Trim = Off Trim width = 1 pixel Number of copies = 1 Film size = 14x17 Medium type = blue Film orientation = portrait Mirror = OFF(normal) Overlay threshold density = 120 Output format 2: Margin between images = 20 pixel Image layout = concentration Annotation: Print server Upper left = (nothing selected) Upper center = (nothing selected) Upper right = (nothing selected) Upper left = (nothing selected) Lower center = (nothing selected) Lower right = (nothing selected) Logging: Network = (Not selected) Printer = (Not selected) DICOM = normal Output image to file = off Precedence = Input Sorting: Sorting conditions = (nothing selected) 2 cameras (each with a separate channel) can be connected to PS551. Only one printer connection is used for the test. File Name Content Remarks None FUJI service utility setting Provided by FUJI 132 Specific Camera Information - Fuji SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 132 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Camera in utility mode PRINTER OFFLINE PRINTER OFFLINE Camera offline Supply magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film Camera is switched off n.a. UNKNOWN Unspecified problem with camera (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 340.0 339.0 0.29 Y 400.0 400.5 0.12 14" x 17" Landscape X 410.0 410.5 0.12 Y 330.0 329.0 0.30 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X 240.0 240.5 0.21 Y 340.0 338.5 0.44 11" x 14" Landscape X 350.0 348.5 0.43 Y 230.0 230.2 0.09 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Fuji 133 Page 133 of 260 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X 190.0 189.0 0.53 Y 230.0 230.0 0.00 8" x 10" Landscape X 230.0 230.5 0.22 Y 180.0 179.0 0.56 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 134 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 134 of 260 5- 5Specific Camera Information - Kodak Kodak DryView 6800 0 General Information 0 Block Diagram Fig. 17: Available Film Sizes Performance and Connections Associations Maximum number of associations supported: 12 Performance Use medical image 4 of the "Reference Images" patient, maximum film size, positive image, 4x5 format, Copies=1, default center/width, magnification type none. The optimum connection (point-to-point) was used. Application Status Film type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 11" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 10" x 12" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 8" x 10" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based Others n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 135 Page 135 of 260 Restrictions NOTE For restrictions not related to HCC, refer to (Restrictions and known effects / p. 8). NOTE For SW version V 1.00 only. (internal built-in MIM Core sw v2.1.b12) The LUT file CTLUTdry has to be used to reach the required image quality resolution in white areas. NOTE No error message is sent if film size of job to be printed is not inserted in camera. NOTE Min. Density is always fog on film. NOTE A Film Jam error will not be sent to modality as specified. NOTE The serrated border line and some pixels of the diagnostic area are cut because of rounded corners. NOTE The standard EN55011 (EMC) is supported with Class A (Hos- pital use) only. Known effects n.a. SCU / modality software configuration 0 Time 65 sec Application Entity Properties Display Changes allowed AE Title DV6800 1 1. Do not use an AE title such as “NER_...” Yes Port number 5040 No 136 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 136 of 260 HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) kodak6800_smallB No DICOM node DV6800 Yes Filming properties Display Changes allowed Hold Printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.154 x 78.154 No Film sheet formats, Portrait Number of pixels [columns x rows] 14" x 17" 4488 x 5464 14" x 14" 4448 x 4448 11" x 14" 3514 x 4488 10" x 12" 3184 x 3828 08" x 10" 2528 x 3184 In “Define new” Do not modify/add Select only Delete only Film sheet formats, Landscape Number of pixels [columns x rows] 14" x 17” 5464 x 4488 14" x 14" 4488 x 4488 11" x 14" 4488 x 3514 10" x 12" 3828 x 3184 08" x 10" 3184 x 2528 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale, 8-bit No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 137 Page 137 of 260 NOTE Do not modify or add film sizes. Do not modify pixel sizes. Delete film sizes that are not available at the customer site. SCP / hardcopy camera configuration (provided by OEM) 0 Identification Printer Settings The following table describes the level (L = level) in the Kodak configuration tool “Kodak Weblink”. Background Black Yes Transformation Replicate No Filming properties Display Changes allowed Manufacturer / device type: DICOM Printer (SCP) (internal print server) Device name: DryView 6800 Manufacturer: Kodak SW Revision: V 1.00 (internal built-in MIM Core sw v2.1.b12);(for VA20) V 2.00 (internal built-in MIM Core sw v2.1.b14) (for VA26) Physical interface: Ethernet 10/100/1000 base T/Tx, Network protocol: TCP/IP DICOM conformance statement: Rev. 5.0, September 26, 2007 Image memory: 786 MB RAM Hard disk: 40 GB 138 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 138 of 260 L1 L2 L3 L4 Sub-Level of L4 Configuration DICOM SCP SCP Configuration Image Optimization Services Provided to SCU - Negotiate PLUT / NO - Negotiate Grayscale Print / YES - Negotiate Color Print / NO Image quality - Tonescaling Method / Perception LUT - NO - TFT Set Name / wrkstn2a.w87 - Always Apply - Polarity / NORMAL - NO - Interpolation / REPLICATE - NO - Density Min / 0.20 - NO - Density Max / 2.80 - NO - Smoothing / 0 - NO - Perception LUT Contrast / 3 - Always Apply - Curve Shape Contrast / 0 - NO - Curve Shape Value / 429 - NO - Wet Pivot Density / 1.2 - NO - Illumination / 2000 - NO - Reflected Ambient Light / 10 - NO Film and Image Options Film and Page Options - Film Size / 14”x17” – NO - Film Base / BLUE FILM – NO - Border Density / 3.10 – NO - Sorter Bin / BIN 1 – NO - Film Orientation / PORTRAIT – NO © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 139 Page 139 of 260 - Trim / NO – NO Image Resizing - Method / MINIFY-Scale – NO - Text Box Location / NONE – Always Apply Other Options Status Reporting - Send Warnings / YES - Always Apply - Send N-Events to SCU / NO - Always Apply Annotation Elements - Print Date / NO - Always Apply - Print Hospital Name / NO - Always Apply - Print Modality ID / NO - Always Apply - Print Time / NO - Always Apply - Print Page Number / NO - Always Apply - Common Text Override / NO - Always Apply - Film Session Label / “empty” /NO Printer and Other Parameters - Printer Priority / NORMAL - NO - Body Part / DEFAULT - NO SCP Config AutoSetup Modality Identification - Source ID / 3.2 - Modality ID / xxxxxxx6800xxxxxx - Modality Type / Other - NO Modality Defaults L1 L2 L3 L4 Sub-Level of L4 140 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 140 of 260 Error and warning messages Image Quality and Optical Density 0 No specific parameter available. - Manufacturer / "empty" - Type / "empty" - Model / "empty" Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Camera cover, drawer or door open COVER OPEN COVER OPEN Camera cover, drawer or door open Unlock magazine PRINTER OFFLINE PRINTER OFFLINE Camera offline Send film to empty 14x17 supply maga- zine EMPTY 14X17 BLUE EMPTY 14X17 BLUE Camera info: EMPTY 14X17 BLUE Camera is warming up PROC INIT PROC INIT Processor initializing Camera in "power save" or "sleep mode" PRINTER OFFLINE PRINTER OFFLINE Camera offline Send job for a film size not inserted in camera n.a. n.a. “nothing” Camera is in calibra- tion PRINTER OFFLINE PRINTER OFFLINE Camera offline (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality L1 L2 L3 L4 Sub-Level of L4 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 141 Page 141 of 260 Real Size Scaling Film size / Direction Desired (mm) Measured (mm) Difference obtained from desired value in % 14" x 17" Portrait X 340.0 338.5 0.44 Y 400.0 400.0 0.00 14" x 17" Landscape X 400.0 400.2 0.05 Y 340.0 338.5 0.44 14" x 14" Portrait X 300.0 298.5 0.50 Y 300.0 300.0 0.00 14" x 14" Landscape X 300.0 300.0 0.00 Y 300.0 298.5 0.50 11" x 14" Portrait X 260.0 260.5 0.19 Y 340.0 338.5 0.44 11" x 14" Landscape X 340.0 338.5 0.44 Y 260.0 260.5 0.19 10" x 12" Portrait X 240.0 238.5 0.62 Y 280.0 280.2 0.07 10" x 12" Landscape X 280.0 280.2 0.07 Y 240.0 238.5 0.62 8" x 10" Portrait X 160.0 160.0 0.00 Y 240.0 238.5 0.62 8" x 10" Landscape X 240.0 238.5 0.62 Y 160.0 160.0 0.00 142 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 142 of 260 Kodak DryView 5800 5.1 General information 0 Block Diagram Fig. 18: Available Film Sizes Performance and Connections Associations Maximum number of associations supported: 12 Performance Use medical image 4 of the "Reference Images" patient, maximum film size, positive image, 4x5 format, Copies=1, default center/width, magnification type none. The optimum connection (point to point) was used. Application Status Film type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 11" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 10" x 12" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 8" x 10" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based Others n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 143 Page 143 of 260 Restrictions NOTE For restrictions not related to HCC, refer to (Restrictions and known effects / p. 8). NOTE Min. Density is always fog on film. NOTE Some dust artifacts (less then five) visible on film. NOTE The EN55011 standard is class A (Hospital use) only. NOTE No error message is sent if film size of job to be printed is not inserted in camera. NOTE If the film supply is empty, no messages are displayed in “Film Task Status” Known effects n.a. SCU / modality software configuration 0 Time 92 sec. Application Entity Properties Display Changes allowed AE Title DV5800 1 1. Do not use an AE title such as “NER_...” Yes Port number 5040 No HC Device / General settings Display Changes allowed Type DICOM printer No 144 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 144 of 260 Class (Printer spec file name) kodak5800 No DICOM node DV5800 Yes Filming properties Display Changes allowed Hold Printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.154 x 78.154 No Film sheet formats, Portrait Number of pixels [columns x rows] 14" x 17" 4412 x 5384 14" x 14" 4412 x 4412 11" x 14" 3436 x 4412 10" x 12" 3104 x 3752 8" x 10" 2452 x 3104 In “Define new” Do not modify/add Select only Delete only Film sheet formats, Landscape Number of pixels [columns x rows] 14" x 17” 5384 x 4412 14" x 14" 4412 x 4412 11" x 14" 4412 x 3436 10" x 12" 3752 x 3104 8" x 10" 3104 x 2452 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale, 8-bit No Background Black Yes Transformation No magnification No HC Device / General settings Display Changes allowed © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 145 Page 145 of 260 NOTE Do not modify or add film sizes. Do not modify pixel sizes. Delete film sizes that are not available at the customer site. SCP / hardcopy camera configuration (provided by OEM) 0 Identification Printer Settings The following table describes the Kodak configuration tool “Kodak Weblink”. Manufacturer / device type: DICOM Printer (SCP) (internal print server) Device name: DryView 5800 Manufacturer: Carestream (Kodak) SW Revision: V1.01.b01 (internal built-in MIM Core SW V3.0.b11) Physical interface: Ethernet 10/100 base T/Tx, RJ45 connector Network protocol: TCP/IP DICOM conformance statement: Rev. 2.0, December 12, 2007 Image memory: 512 MB RAM Hard disk: 80 GB 146 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 146 of 260 Name (on Configura- tion) Setting System, Network Host Name DV5800DRE IPAddr accordingly Subnet Mask accordingly Default Gateway accordingly Connection Name LAN DICOM SCP, Communications Dicom Source Communications Port 5040 Association Limit 12 DICOM SCP, Destination Identification AETiltle=DV5800 Media: Media Type avail./PageExtent(x,y)/ImageExtent(x,y)/ImageOrigin(x,y) 8x10, blue&clear selected 2590x3264, 2452x3107, 74, 69 10x12, blue&clear selected 3264x3890, 3107x3752, 69, 64 11x14, blue&clear selected 3575x4576, 3437x4412, 74, 69 14x14, blue&clear selected 4576x4550, 4412x4412, 69, 64 14x17, blue&clear selected 4576x5525, 4412x5387, 69, 64 Page Image Options: Min Vert Sep=2, Min Horiz Sep=2 Max Band Page=10, Max Img Band=10 Pixel Pitch=12.795, Border DMax=3.10 Image Dmin=0.00, Image DMax=3.10 Lines Image Annot=1, Lines Page Annot=2 Image Annot Height=52, Page Annot Height=52 Max Magnif.Factor=20, Max Minif.Factor=0.1 Trim Width=2, Accept Annotations=Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 147 Page 147 of 260 Accept Color Image=Yes, Accept BW Image=Yes Mix Aspect Ratio Page=Y, Mix Aspect Ratio Row=Y Mix Image Size Std Fmt=Y, Mix Image Size Row=Y Mix Req.Size Page=Y, Minify Image To Fit=Y Scale Image To Fit=Y, Crop Image To Fit=Y Req.Size OK=Y, Configuration Notes=empty DICOM SCP, select specific modality, Modify: SCP Configuration, Image Optimization Services Provided to SCU Negotiate Presentation LUT No Negotiate Color Print No Image quality Smoothing Type 0 - Always Apply Interpolation NONE - No TFT SeT Wrkstn2a.W87 -Always Apply Perception LUT Con- trast 1 - Always Apply Image Polarity Normal - No Image DMin 0.00 - No Image DMax 3.10 - No Illumination 2000 - No Reflected Ambient Light 10 - No SCP Configuration, Film and Image Options Film and Page Options Film size 14IN x 17IN - No Film Base Blue Film - No Film orientation Portrait - No) Name (on Configura- tion) Setting 148 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 148 of 260 Border density 3.10 - No Trim No - No Image Resizing Method Minify/Scale - No SCP Configuration, Other Options Status Reporting Report Warnings YES - Always Apply Send N-Events to SCU No Always Apply Film Session Elements Capture Date No Capture Time No Hosp.Name No Study Page Number No Modality ID No Film Session Label Override No Printer and Other Parameters Printer Priority Normal - No SCP Configuration, Modality Preferences Modality Identification Modality ID PR_ Hostname Modality Type Other - No Modality Defaults Manufacturer “empty” Type “empty” Model “empty” Name (on Configura- tion) Setting © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 149 Page 149 of 260 Error and warning messages Image Quality and Optical Density 0 No specific parameter available. Real Size Scaling Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Camera is warming up PROC INIT PROC INIT Processor initializing Film 14x17 supply empty EMPTY 14x17 BLUE NORMAL Camera is ready Cover or door of camera open COVER OPEN COVER OPEN Camera cover, drawer or door open Send job for a film size not inserted in camera n/a n/a Camera is ready (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Difference obtained from desired value in % 14" x 17" Portrait X 320.0 320.0 0.00 Y 410.0 410.0 0.00 14" x 17" Landscape X 410.0 410.0 0.00 Y 330.0 329.5 0.15 14" x 14" Portrait X 330.0 330.0 0.00 Y 330.0 330.5 0.15 14" x 14" Landscape X 330.0 330.5 0.15 Y 330.0 329.5 0.15 11" x 14" Portrait X 260.0 260.0 0.00 Y 330.0 330.0 0.00 11" x 14" Landscape X 320.0 320.0 0.00 Y 260.0 260.5 0.19 150 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 150 of 260 10" x 12" Portrait X 230.0 230.0 0.00 Y 280.0 280.5 0.18 10" x 12" Landscape X 280.0 280.0 0.00 Y 230.0 230.0 0.00 8" x 10" Portrait X 180.0 180.0 0.00 Y 230.0 230.0 0.00 8" x 10" Landscape X 230.0 229.5 0.22 Y 170.0 170.0 0.00 Film size / Direction Desired (mm) Measured (mm) Difference obtained from desired value in % © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 151 Page 151 of 260 Kodak DryView 8900 (small border) 5.2 General information 0 Block diagram Fig. 19: Available film sizes Performance and Connections Associations Maximum number of associations supported: 12 Format Release status Film Type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 11" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 10" x 12" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 8" x 10" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based Other N/A N/A N/A Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 152 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 152 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The minimum density command is not supported. The mini- mum density value is the value of the fog on the film. NOTE The round edge of the film sheet cuts the diagnostic area. Known Effects n.a. SCU / Modality Software Configuration 0 Time 71 sec. Application Entity Properties Display Changes allowed AE Title DV8900 1 1. Please do not use an AE Title such as “NER_...” Yes Port number 5040 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) kodak8900_smallB No DICOM Node DV8900 Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 153 Page 153 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.154 x 78.154 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4488 x 5464 14" x 14" 4488 x 4488 11" x 14" 3514 x 4488 10" x 12" 3184 x 3828 8" x 10" 2528 x 3184 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5464 x 4488 14" x 14" 4488 x 4488 11" x 14" 4488 x 3514 10" x 12" 3828 x 3184 8" x 10" 3184 x 2528 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation Replicate No 154 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 154 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings Manufacturer / device type: DICOM Print Server (SCP) Device name: DryView 8900 Manufacturer: Kodak SW Revision: V 3.17, MIM 5.6.b14 with WIN 2000 Physical type: Ethernet 10/100 /1000 base T/Tx, RJ45 Network protocol: TCP/IP DICOM Conformance Statement: Rev. C, January 28, 2004. Image memory: 786 MB RAM Hard disk: 40 GB Content 8900 setup: (Provided by Kodak) under Configuration, System, Network: Host Name=DV8900, IPAddr=accordingly Subnet Mask=accordingly, Gateway Addr=accordingly under Configuration, DICOM SCP, Communications: Port=5040, Association Limit=12, Source Name=DICOM under Configuration, Destination: General Remarks: Log. Name=8900 Media types: Media=35x43cm, 9100x11037, 10781, any Media types: Media=35x35 cm, 9100x9087, 8831, Any Media types: Media=11"x14", 7137x9100, 8844, Any Media types: Media=10"x12", 6490x7767, 7511, Any Media types: Media=8"x10", 5167x6490, 6234, Any Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On Formatting: DICOM Annotation Box=On, Req. Image Size=On Formatting: Req. Size Scale=On, Req. Size Mix Page=On Formatting: Req. Size Mix Row=On, Trim=On, Formatting: True Landscape=On, Rotation=On Formatting: Minify/Crop=On, Tone Scaling on Image Basis=On Formatting: Max Img Band=20, Max Band Page=20, Max Img Cols=0 Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 Formatting: Min Vert Sep=4, Trim Width Enabled=4 Formatting: Trim Width Disabled=0, Maximum DMAX=3.30 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 155 Page 155 of 260 Error / Warning Messages (examples) Content 8900 setup: (Provided by Kodak) under Configuration, DICOM SCP, SCP Services, Negotiate Presentation LUT=NO, TFT/ULUT= Wrkstn2a.w87 (Always=Y) Contrast= 3 (Always=Y), Smoothing type=0 (Always=Y), Polarity= Normal, (Always=N) Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) NeventReports=No (Always=Y), Warnings=Yes Print Priority=Normal (Always=N), Border=3.99 (Always=N) 2mmBorder=yes Film Clip Border = No Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) Sorter Bin=Bin1 (Always=N), Include print date in annotation=No Include print time in annotation=No Include page number in annotation=No Include hospital name in annotation=No Include modality ID in annotation=No Modality ID=PR_ xxx.xxx.xxx Annotation Override=No, Density Patch = No Image Resizing=Minify/Scale (Always=N), Text Box Location=None, Source ID=DI016 Action that results in camera error messages Printer messages Messages displayed on SCU (*2) Defined DCS (*1) Sent by SCP Cover or door of camera open COVER OPEN COVER OPEN Camera cover, drawer or door open Camera is warming up PROC INIT PROC INIT Processor initializing Supply magazine empty EMPTY 14X17 BLUE EMPTY 14X17 BLUE Camera info: EMPTY 14X17 BLUE Magazine with damaged chip inserted BAD SUPPLY MGZ BAD SUPPLY MGZ Problem with supply magazine 156 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 156 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Action that results in camera error messages Printer messages Messages displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 340.0 340.0 0.00 Y 410.0 411.0 0.24 14" x 17" Landscape X 400.0 401.0 0.25 Y 330.0 330.0 0.00 14" x 14" Portrait X 340.0 339.5 0.15 Y 330.0 330.0 0.00 14" x 14" Landscape X 340.0 340.0 0.00 Y 330.0 330.0 0.00 11" x 14" Portrait X 270.0 270.0 0.00 Y 330.0 330.0 0.00 11" x 14" Landscape X 340.0 340.0 0.00 Y 250.0 250.0 0.00 10” x 12” Portrait X 240.0 240.0 0.00 Y 280.0 280.0 0.00 10” x 12” Landscape X 290.0 290.0 0.00 Y 230.0 230.0 0.00 8" x 10" Portrait X 190.0 190.0 0.00 Y 230.0 230.0 0.00 8" x 10" Landscape X 240.0 240.0 0.00 Y 180.0 180.0 0.00 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 157 Page 157 of 260 Kodak DryView 8700-Plus / PACS Link MIM 200 5.3 General information 0 Block diagram Fig. 20: Available film sizes Performance and Connections Associations Maximum number of associations supported: 13 Format Release status Film Type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 158 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 158 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Camera does not support minimum density command. NOTE The background command does not work properly. Camera doesn't support background white. Known Effects n.a. SCU / Modality Software Configuration 0 Time 120 sec. Application Entity Properties Display Changes allowed AE Title DV8700 1 1. Please do not use an AE title such as “NER_...” Yes Port number 5040 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) imation8700 No DICOM Node DV8700 Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 159 Page 159 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.0 x 78.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4096 x 5220 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5220 x 4096 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No Device type: DICOM Print Server (SCP) Device name: PACS Link MIM 200 Manufacturer: Kodak SW Revision: V 6.1.1 Physical Interface: Ethernet (RJ45) Network protocol: TCP/IP DICOM Conformance Statement: Rev. J., June 20, 2005 Image memory: 256 MB Hard disk: 4 GB 160 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 160 of 260 Printer settings Device type: Printer Device name: DryView 8700 Manufacturer: Kodak SW Revision: 1.34 Physical Interface: Fiber optic Network protocol: None DICOM Conformance Statement: None Image memory: 32 MB Hard disk: n.a. Content: Configuration MIM 200 setup Under Configure, Network: Node Name=MIM, IPAddr=accordingly Subnet Mask=accordingly, Gateway Addr=accordingly under Configure, Input, Network, Add: Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 under Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 161 Page 161 of 260 General: Log.Name=8700 General: Database Name=8700, Model=8700, Memory=32 Media info.: Media=35x43cm, 4096x5223, 5133, blue Output parameters.: Cmd=SuperSet, Baud=19200, Data=8,Stop=1, Parity=None Output parameters.: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 Supported item: Collation=On, Text=On, Tone Scaling=On, Rotation=On Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On Format types: Custom=On, Slide=On, Row Symmetric=On Format types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On Formatting: DICOM Annotation Box=On, Req.Size Scale=On Formatting: Req.Size Mix in Row=On, Trim=On Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On Formatting: Req.Image Size=On, Req.Size Mix on Page=On Formatting: True Landscape=On Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 Formatting: Trim Width Enabled=2, Trim Width Disabled=0 Formatting: Pixel Pitch=12.8205 Image processing: Gray scale=On, Minimize=On, Max Image Dmax=3.1 M952 usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 Under Configure, SCP Services, select the specific modality, modify: Content: Configuration 162 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 162 of 260 Error / Warning Messages (examples) Image resizing Resizing <M/S>=Minify/Scale, Always Apply=N Relocate Text Box, Location = none N-EVENT Reporting, Reporting=N, Always Apply=Y Warning Status=Y PLUT=N Tone Scaling=PL (PerceptionLUT), Always Apply=Y Curve Shape/TFT, TFT/ULUT= Wrkstn2a.w87, Always Apply=Y Contrast (dry)=01, Always Apply=Y Interp. /Smoothing, Smoothing Type=0, Always Apply=N Image Dmin=0.00, Always Apply=N, Image Dmax=3.00, Always Apply=N Polarity=Normal, Always Apply=N Border=3.99, Always Apply=N Size=14"x17", Always Apply=N Base=Blue Film, Always Apply=N Priority=Normal, Always Apply=N Page Annotation, Annotation Setup, Always Apply=N, Modality ID=Off, Hospital Name=Off, Print Date=Off, Print Time=Off, Page Number=Off Basic Color=N 8700 Plus setup under COMM Menu: 969 default under IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 under EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Time- out=60 Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film Open Top Cover COVER OPEN COVER OPEN Camera cover, drawer or door open Camera switched off PRINTER DOWN PRINTER DOWN Camera down No supply magazine inserted NO SUPPLY MGZ NO SUPPLY MGZ Film supply not avail- able Camera is warming up PRINTER BUSY PRINTER BUSY Camera initializing Film jam in camera FILM JAM FILM JAM Film jam Content: Configuration © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 163 Page 163 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 310.0 310.5 0.16 Y 390.0 390.0 0.00 14" x 17" Landscape X 390.0 390.5 0.13 Y 310.0 310.5 0.16 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 164 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 164 of 260 Kodak DryView 8700-Dual / PACS Link MIM 9410 5.4 General information 0 Block diagram Fig. 21: Available film sizes Performance and Connections Associations Maximum number of associations supported: 10 Format Release status Film Type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 165 Page 165 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Camera does not support minimum density command. NOTE The background command does not work properly. Camera doesn't support background white. Known Effects n.a. SCU / Modality Software Configuration 0 Time 128 sec. Application Entity Properties Display Changes allowed AE Title 9410 Yes Port number 1024 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) imation8700 No DICOM Node DV8700 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes 166 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 166 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Pixel Size [1/1000 mm] 78.0 x 78.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4096 x 5220 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5220 x 4096 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No Filming properties Display Changes allowed Manufacturer / device type: DICOM Print Server (SCP) Printer Device name: PACS Link 9410 DryView 8700Dual Manufacturer: Kodak Kodak SW Revision: V 1.6 1.34 Physical type: 100/10 base T Ethernet, UTP/STP Fiber Optic Network protocol: TCP/IP n.a. DICOM Conformance State- ment: Version 2.0, June 5, 2000 n.a. Image memory: 128 MB 32 MB Hard disk: 4.1 GB n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 167 Page 167 of 260 Printer settings Error / Warning Messages (examples) Content: Configuration MIM 9410 setup under Device Setup, LOCAL PRINTERS:: Printer=8700, Model=8700 Dual, Output=Fiber, Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz Film Mismatch=Print Always, Interpolation Type=831 Interp Num=2, Max.Density=300, Contrast=6, Border=0 TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 under Device Setup, SCP PRINTERS, Current Providers: Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 10 under Device Setup, SCP PRINTERS, Registered Users: SCU AETitle= PR_cthostname, IPAddr=accordingly SCP=8700, Copies=1, Contrast Table=1, TFT/ULUT= Wrkstn2a.w87 Max.Density= 280, Border Density=0, Mag.Type=8, Smoothing=0 Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No Trim=No, Attribute Warning=Yes Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus setup under COMM Menu: 969 default under IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 under EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Time- out=60 Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Camera switched off PRINTER DOWN PRINTER DOWN Camera down Cover or door of camera open COVER OPEN COVER OPEN Camera cover, drawer or door open No supply magazine inserted NO SUPPLY MGZ NO SUPPLY MGZ Film supply not avail- able 168 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 168 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Camera is in calibra- tion CALIBRATING ERR CALIBRATING ERR Problem when cali- brating Film quality may not be optimal Camera is warming up PRINTER INIT PRINTER INIT Camera initializing (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 300.0 300.5 0.17 Y 400.0 400.2 0.05 14" x 17" Landscape X 400.0 400.2 0.05 Y 300.0 300.5 0.17 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 169 Page 169 of 260 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 170 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 170 of 260 Kodak DryView 8200 / PACS Link MIM 200 5.5 General information 0 Block diagram Fig. 22: Available film sizes Performance and Connections Associations Maximum number of associations supported: 12 Format Release status Film Type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 11" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 171 Page 171 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The minimum density command is not supported. NOTE The background command does not work properly. The bor- der is always black. Known Effects n.a. SCU / Modality Software Configuration 0 Time 228 sec. Application Entity Properties Display Changes allowed AE Title DV8200 1 1. Please do not use an AE title such as “NER_...” Yes Port number 5040 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (printer spec file name) kodak8200 No DICOM Node Kodak8200 Yes 172 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 172 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.0 x 78.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4360 x 5220 14" x 14" 4360 x 4244 11" x 14" 3272 x 4360 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5220 x 4360 14" x 14" 4244 x 4360 11" x 14" 4360 x 3272 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No Device type: DICOM Print Server (SCP) Device name: PACS Link MIM 200 Manufacturer: Kodak SW Revision: V 6.1.1 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 173 Page 173 of 260 Printer settings Physical Interface: Ethernet 10/100 base T/Tx Network protocol: TCP/IP DICOM Conformance Statement: DCM, Rev. J, June 20, 2005 Image memory: 256 MB RAM Hard disk: 4 GB Device type: Printer Device name: DryView 8200 Manufacturer: Kodak SW Revision: 3.5 Physical Interface: 100/10 base T Ethernet Network protocol: TCP/IP DICOM Conformance Statement: n.a. Image memory: 50 MB Hard disk: n.a. Content: Configuration MIM 200 setup Under Configure, Network: Node Name=MIM, IPAddr=accordingly Subnet Mask=accordingly, Gateway Addr=accordingly under Configure, Input, Network, Add: Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 under Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: Device type: DICOM Print Server (SCP) 174 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 174 of 260 General Remarks: Log.Name=8200, IPAddr=100.100.100.40 General Remarks: Database Name=8200, Model=8200, Memory 32 Media info.: Media=35x43cm, 4361x5223, 5133, Any (Blue, Clear) Media=35x35cm, 4361x4247, 4157, any (blue, clear) Media=11inx14in, 3272x4361, 4271, any (blue, clear) Supported item: Collation=On, Text=On, Tone Scaling=On, Supported item: Remote Image Deletion=On, Rotation=On Interpolation: No Magnification=On, Bilin=On, Repl=On, Interpolation: CubicSpline=On, Cubic Convolution 2=On Format types: Custom=On, Slide=On, Row Symmetric=On Format types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On Formatting: DICOM Annotation Box=On, Req.Size Scale=On Formatting: Req.Size Mix in Row=On, Trim=On Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On Formatting: Req.Image Size=On, Req.Size Mix on Page=On Formatting: True Landscape=On Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 Formatting: Trim Width Enabled=2, Trim Width Disabled=0 Formatting: Pixel Pitch=12.8205 Image processing: Gray scale=On, Minimize=On, Max Image Dmax=3.1 SCU: Density Space=On, Variable Border=On, PLUT Service=On SCU: Curve Shape Tone Scaling=On, Perception LUT Tone Scaling=On M952 usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 Content: Configuration © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 175 Page 175 of 260 Error / Warning Messages (examples) Under Configure, SCP Services, select the specific modality, modify: Image Resizing, Resizing <M/S>=Minify/Scale, Always Apply=N Relocate Text Box, Location = none N-EVENT Reporting, Reporting=N, Always Apply=Y Warning Status=Y PLUT=N Tone Scaling=PL (PerceptionLUT), Always Apply=Y Curve Shape/TFT, TFT/ULUT=Wrkstn2a.w87, Always Apply=Y Contrast (dry)=01, Always Apply=N Interp. /Smoothing, Smoothing Type=0, Always Apply=N Image Dmin=0.00, Always Apply=N, Image Dmax=3.00, Always Apply=N Polarity=Normal, Always Apply=N Border=3.99, Always Apply=N Size=14"x17", Always Apply=N Base=Blue Film, Always Apply=N Priority=Normal, Always Apply=N Page Annotation, Annotation Setup, Always Apply=N, Modality ID=Off, Hospital Name=Off, Print Date=Off, Print Time=Off, Page Number=Off Basic Color=N 8200 setup under the CONFIGURATION menu: On IMAGE QUALITY-> TFT FILES menu: TFT=Ver693c0.w87 under the LOCAL PANEL Menu: Contrast=6, Density=3.00 under the DICOM Menu: SCU config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 DICOM config.: AE=ANY_ANY, Port=1025 Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Supply magazine not inserted NO SUPPLY MGZ NO SUPPLY MGZ Film supply not avail- able Less than 5 films in supply magazine SUPPLY LOW SUPPLY LOW Film supply low Supply magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film Camera is warming up PRINTER INIT PROC INIT PRINTER INIT PROC INIT Camera initializing Processor initializing Camera switched off PRINTER DOWN PRINTER DOWN Camera down Content: Configuration 176 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 176 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 400.0 398.5 0.38 14" x 17" Landscape X 390.0 389.5 0.13 Y 330.0 330.0 0.00 14" x 14" Portrait X 330.0 330.0 0.00 Y 320.0 319.5 0.16 14" x 14" Landscape X 320.0 319.5 0.16 Y 330.0 330.0 0.00 11" x 14" Portrait X 250.0 249.5 0.20 Y 330.0 330.5 0.15 11" x 14" Landscape X 330.0 330.0 0.00 Y 240.0 240.0 0.00 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 177 Page 177 of 260 Kodak DryView 8100 / PACS Link MIM 200 5.6 General information 0 Block diagram Fig. 23: Available film sizes Performance and Connections Associations Maximum number of associations supported: 12 Format Release status Film Type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 178 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 178 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The minimum density command is not supported. NOTE The background command does not work properly. The Bor- der Density is always black. Known Effects n.a. SCU / Modality Software Configuration 0 Time 234 sec. Application Entity Properties Display Changes allowed AE Title DV8100 1 1. Please do not use an AE title such as “NER_...” Yes Port number 5040 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) kodak8100 No DICOM Node Kodak8100 Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 179 Page 179 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.0 x 78.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4096 x 5216 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5216 x 4096 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No Device type: DICOM Print Server (SCP) Device name: PACS Link MIM 200 Manufacturer: Kodak SW Revision: V 6.1.1 Physical Interface: Ethernet 10/100base T/Tx Network protocol: TCP/IP DICOM Conformance Statement: Rev. J, June 20, 2005 Image memory: 256 MB RAM Hard disk: 4 GB 180 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 180 of 260 Printer settings Device type: Printer Device name: DryView 8100 Manufacturer: Kodak SW Revision: 2.7 Physical Interface: n.a. Network protocol: n.a. DICOM Conformance Statement: n.a. Image memory: 32 MB Hard disk: None Content: Configuration MIM 200 setup Under Configure, Network: Node Name=MIM, IPAddr=accordingly Subnet Mask=accordingly, Gateway Addr=accordingly under Configure, Input, Network, Add: Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 under Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 181 Page 181 of 260 General Remarks: Log.Name=8100, General Remarks: Database Name=8100, Model=8100, Memory 32 Media info.: Media=35x43cm, 4096x5223, 5133, blue Output parameters.: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even Output parameters.: Pixel=12, Header/Line, Transfer=1000 KHz, Acq=60 Supported item: Collation=On, Text=On, Tone Scaling=On, Rotation=On Interpolation: NoMag=On, Bilin=On, Repl=On, CubicSpline=On Format types: Custom=On, Slide=On, Row Symmetric=On Format types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On Formatting: DICOM Annotation Box=On, Req.Size Scale=On Formatting: Req.Size Mix in Row=On, Trim=On Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On Formatting: Req.Image Size=On, Req.Size Mix on Page=On Formatting: True Landscape=On Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 Formatting: Trim Width Enabled=2, Trim Width Disabled=0 Formatting: Pixel Pitch=12.8205 Image processing: Gray scale=On, Minimize=On, Max Image Dmax=3.1 M952 usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 Under Configure, SCP Services, select the specific modality, modify: Content: Configuration 182 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 182 of 260 Error / Warning Messages (examples) Image resizing Resizing <M/S>=Minify/Scale, Always Apply=N Relocate Text Box, Location = none N-EVENT Reporting, Reporting=N, Always Apply=Y Warning Status=Y PLUT=N Tone Scaling=PL (PerceptionLUT), Always Apply=Y Curve Shape/TFT, TFT/ULUT=Wrkstn2a.w87, Always Apply=Y Contrast (dry)=01, Always Apply=Y Interp. /Smoothing, Smoothing Type=0, Always Apply=N Image Dmin=0.00, Always Apply=N, Image Dmax=3.00, Always Apply=N Polarity=Normal, Always Apply=N Border=3.99, Always Apply=N Size=14"x17", Always Apply=N Base=Blue Film, Always Apply=N Priority=Normal, Always Apply=N Page Annotation, Annotation Setup, Always Apply=N, Modality ID=Off, Hospital Name=Off, Print Date=Off, Print Time=Off, Page Number=Off Basic color=N 8100 setup under the CONFIGURATION menu: On SIB board (i.e. external switch below control plugs): SW1=Down Under the COMMUNICATIONS Menu: Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,... P6=0 On IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off On IMAGE QUALITY-> TFT FILES menu: TFT=Ver693c0.w87 under the LOCAL PANEL Menu: Contrast=6, Density=3.00 Under the SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 Under the DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Top cover or door open COVER OPEN COVER OPEN Camera cover, drawer or door open Supply magazine empty SUPPLY EMPTY SUPPLY EMPTY Camera out of film Content: Configuration © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 183 Page 183 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Supply magazine not inserted NO SUPPLY MGZ NO SUPPLY MGZ Film supply not avail- able (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 310.0 310.0 0.00 Y 400.0 401.5 0.37 14" x 17" Landscape X 390.0 391.5 0.38 Y 310.0 310.5 0.16 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 184 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 184 of 260 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 185 Page 185 of 260 Kodak DryView 8150 5.7 General information 0 Block diagram Fig. 24: Available film sizes Performance and Connections Associations Maximum number of associations supported: 12 Format Release status Film type Medium type 14" x 17" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 14" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 11" x 14" Portrait Yes DVB Blue-based Landscape Yes DVB Blue-based 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 186 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 186 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The European Standard EN55011 is supported only with Class A (hospital use). NOTE The minimum density command is not supported. The mini- mum density value is the value of the fog on the film. Known Effects n.a. SCU / Modality Software Configuration 0 Time 146 sec. Application Entity Properties Display Changes allowed AE Title DV8150 1 1. Please do not use an AE Title such as “NER_...” Yes Port number 5040 No HC Device / General settings Display Changes allowed Type DICOM Printer No Class (Printer spec file name) kodak8150 No DICOM node DV8150 Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 187 Page 187 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.12 x 78.12 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4438x5390 14" x 14" 4438x4414 11" x 14" 3440x4438 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5390x4438 14" x 14" 4414x4438 11" x 14" 4438x3440 Medium type Blue film Yes Film destination Processor No Color appearance Gray scale 8 bit No Background Black Yes Transformation No magnification No Manufacturer / device type: DICOM Printer (SCP) Device name: DryView 8150 Manufacturer: Kodak SW Revision: V1.1.b04 / MIM_V5.7.b12 188 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 188 of 260 Printer settings Physical type: Ethernet 10/100 base T/Tx Network protocol: TCP/IP DICOM Conformance Statement: Rev. 1.0, July 27, 2004 Image memory: 786 MB RAM Hard disk: 40 GB DICOM SCP / Communications Port number 5040 Association Limit 12 Source Name DICOM DICOM SCP / Cropping No settings available DICOM SCP / SCP Services / Image Optimization Negotiate Presentation LUT No Negotiate Color Print No TFT Set Name LINODS.w87 Always Apply TFT Set Yes Contrast 4 Always Apply Contrast Yes Smoothing Type 0 Always Apply Smoothing Type No Image DMin 0.00 Always Apply Image DMin No Image DMax 3.00 Always Apply Image DMax No Image Polarity Normal Always Apply Image Polarity No Manufacturer / device type: DICOM Printer (SCP) © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 189 Page 189 of 260 DICOM SCP / SCP Services / Other Options Send N-Event Reports No Always Apply Send N-Event Reports Yes Send Warnings Yes Print priority Normal Always Apply Print Priority No Border Type 3.99 Always Apply Border Type No 2mm Border No Film Clip Border No Film Base Blue Film Always Apply Film Base No Film Size 14 IN X 17 IN Always Apply Film Size No Include Print date in Annotation No Include Print time in Annotation No Include Page Number in Annotation No Include Hospital Name in Annotation No Include modality ID in Annotation No Modality ID PR_hostname Annotation Override No Density Patch No Image Resizing Minify/Scale Always Apply Image Resizing No Text Box Location None Source ID DI000 190 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 190 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Supply magazine empty EMPTY 14X17 BLUE EMPTY 14X17 BLUE Camera info: EMPTY 14X17 BLUE Cover or door of camera open COVER OPEN COVER OPEN Camera cover, drawer or door open Magazine with dam- aged chip inserted BAD SUPPLY MGZ BAD SUPPLY MGZ Problem with supply magazine Camera in calibration PRINTER DOWN PRINTER DOWN Camera offline (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 328.5 0.45 Y 410.0 409.5 0.12 14" x 17" Landscape X 410.0 410.0 0.00 Y 330.0 328.5 0.45 14" x 14" Portrait X 330.0 327.5 0.76 Y 330.0 330.0 0.00 14" x 14" Landscape X 330.0 330.0 0.00 Y 330.0 327.5 0.76 11" x 14" Portrait X 250.0 250.0 0.00 Y 330.0 327.5 0.76 11" x 14" Landscape X 330.0 327.5 0.76 Y 250.0 250.0 0.00 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 191 Page 191 of 260 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 192 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 192 of 260 Kodak KELP 2180/PACS Link MIM 200 5.8 General information 0 Block diagram Fig. 25: Available film sizes Performance and Connections Associations Maximum number of associations supported: 11 Format Release status Film Type Medium type 14" x 17" Portrait Yes EHN-10 Blue-based Landscape Yes EHN-10 Blue-based 14" x 14" Portrait Yes DHG-10 Blue-based Landscape Yes DHG-10 Blue-based 11" x 14" Portrait Yes DHG-10 Blue-based Landscape Yes DHG-10 Blue-based 10" x 12" Portrait N/A N/A N/A Landscape N/A N/A N/A 8" x 10" Portrait Yes DHG-10 Blue-based Landscape Yes DHG-10 Blue-based Other N/A N/A N/A Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 193 Page 193 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). Known Effects n.a. SCU / Modality Software Configuration 0 Time 115 sec. Application Entity Properties Display Changes allowed AE Title K2180 1 1. Please do not use an AE title such as “NER_...” Yes Port number 5040 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (printer spec file name) kodak2180 No DICOM Node Kelp 2180 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 79.0 x 79.0 No 194 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 194 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4096 x 5156 14" x 14" 4096 x 4132 11" x 14" 3236 x 4132 8" x 10" 2284 x 2836 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5156 x 4096 14" x 14" 4132 x 4096 11" x 14" 4132 x 3236 8" x 10" 2836 x 2286 Medium type Blue film Yes Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No Filming properties Display Changes allowed Device type: DICOM Print Server (SCP) Device name: PACS Link MIM 200 Manufacturer: Kodak SW Revision: V 6.1.1 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 195 Page 195 of 260 Printer settings Physical Interface: Ethernet 10/100 base T/Tx Network protocol: TCP/IP DICOM Conformance Statement: Rev. J, June, 2005 Image memory: 256 MB RAM Hard disk: 4 GB Manufacturer / device type: Printer Device name: KELP 2180 Manufacturer: Kodak SW Revision: V 2.17H Physical type: None Network protocol: None Manufacturer´s specifications: None Image memory: 24 MB Hard disk: None Content: Configuration MIM 200 setup Under Configure, Network: Computer Name=e.g., Kodak2180, IPAddr=accordingly Subnet Mask=accordingly, Gateway Addr=accordingly under Configure, Input, Network, Add: Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 Under Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: Device type: DICOM Print Server (SCP) 196 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 196 of 260 General Remarks: Log.Name=KELP2180, Database Name=2180 General Remarks: Model=KELP2180, Memory 24, Node ID=6 or accordingly Media info.: Media=35x43cm, 4136x5160, 5030, (blue) Media=35x35cm, 4136x4136, 4006, (blue) Media=11"x14", 3240x4136, 4006, (Blue) Media=8"x10", 2290x2840, 2710, (Blue) Supported item: Collation=On, Text=On, Tone Scaling=On, Rotation=On Interpolation: No Mag=On, Bil=On, Repl=On, Cubic=On, Cubic 2=On Format types: Custom=On, Slide=On, Row Symmetric=On Format types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On Formatting: DICOM Annotation Box=On, Req.Size Scale=On Formatting: Req.Size Mix in Row=On, Trim=On Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On Formatting: Req.Image Size=On, Req.Size Mix on Page=On Formatting: True Landscape=On Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 Formatting: Trim Width Enabled=2, Trim Width Disabled=2 Formatting: Pixel Pitch=12.6582 Image processing: Gray Scale=On, Minimize=On, Max Image Dmax=3.2 M952 usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 Under Configure, SCP Services, select the specific modality, modify: Content: Configuration © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Kodak 197 Page 197 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Image Resizing, Resizing <M/S>=Minify/Scale, Always Apply=N Relocate Text Box, Location = none N-EVENT Reporting, Reporting=N, Always Apply=Y Warning Status=Y PLUT=N Tone Scaling=CS (Curve Shape), Always Apply=Y Curve Shape/TFT, Curve Shape=0.0, Always Apply=Y Contrast (wet)=+0, Always Apply=N Interpolation=No Mag., Always Apply=N Image Dmin=0.00, Always Apply=N, Image Dmax=2.80, Always Apply=N Polarity=Normal, Always Apply=N Border=3.99, Always Apply=N Size=14"x17", Always Apply=N Base=Blue Film, Always Apply=N Priority=Normal, Always Apply=N Page Annotation, Annotation Setup, Always Apply=N, Modality ID=Off, Hospital Name=Off, Print Date=Off, Print Time=Off, Page Number=Off Film Output = 9(no. of sorter), Always Apply=N Basic color = N 2180 setup: Optical Interface Board will automatically configure to 2180, no setup needed Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP The switch “Access magazines” is acti- vated PRINTER OFFLINE PRINTER OFFLINE Camera offline Send film size which is not inserted in camera CHECK PRINTER CHECK PRINTER Check camera Printing is stopped PRINTER OFFLINE PRINTER OFFLINE Camera offline (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Content: Configuration 198 Specific Camera Information - Kodak SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 198 of 260 Real Size Scaling Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 310.0 310.0 0.00 Y 390.0 389.5 0.13 14" x 17" Landscape X 390.0 389.5 0.13 Y 320.0 320.0 0.00 14" x 14" Portrait X 310.0 310.0 0.00 Y 320.0 319.5 0.16 14" x 14" Landscape X 310.0 309.5 0.16 Y 320.0 320.0 0.00 11" x 14" Portrait X 240.0 240.0 0.00 Y 320.0 319.5 0.16 11" x 14" Landscape X 310.0 309.5 0.16 Y 240.0 240.0 0.00 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X 170.0 170.0 0.00 Y 210.0 209.5 0.24 8" x 10" Landscape X 210.0 209.5 0.24 Y 170.0 1700 0.00 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 199 Page 199 of 260 6- 6Specific Camera Information - Konica Minolta Konica Minolta DryPro 832 0 General Information 0 Block Diagram Fig. 26: Available Film Sizes Performance and Connections Associations Maximum number of associations supported: 9 Format Release status Film type Medium type 14" x 17" Portrait Yes DRYPRO SD-Q Blue-based Landscape Yes DRYPRO SD-Q Blue-based 14" x 14" Portrait Yes DRYPRO SD-Q Blue-based Landscape Yes DRYPRO SD-Q Blue-based 11" x 14" Portrait Yes DRYPRO SD-Q Blue-based Landscape Yes DRYPRO SD-Q Blue-based 10" x 12" Portrait Yes DRYPRO SD-Q Blue-based Landscape Yes DRYPRO SD-Q Blue-based 8" x 10" Portrait Yes DRYPRO SD-Q Blue-based Landscape Yes DRYPRO SD-Q Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 200 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 200 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, 4x5 format, Copies=1, default center/width, magnification type none. The optimum connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Magnification "NONE" not supported therefore Konica Server needs a fixed setting: Magnification "CUBIC" with smoothing type 7. NOTE If “Camera cover open”, no message is displayed. If the cam- era is ready, jobs will be queued but not printed. NOTE If a film is not inserted, but configured in camera server, the queue is stopped with a camera software problem. This job must be deleted from the camera queue. Known effects NOTE The DICOM Print Server PRINTLINK 5 is not 510k registered. NOTE Two film sizes can be installed at Drypro 832. To install other film sizes the Konica-Minolta Service Technician is needed. SCU / modality software configuration 0 Time 62 sec. Application Entity Properties Display Changes allowed AE Title DPRO832 Yes Port number 104 No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 201 Page 201 of 260 HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec. file name) konicaDryPro832_largeB No DICOM Node Konica832 Yes Filming properties Display Changes allowed Hold printed film jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.6 x 78.6 No Film sheet formats, Portrait Number of pixels [columns x rows] 14" x 17" 4344 x 5196 14” x 14” 4344 x 4230 11" x 14" 3390 x 4230 10” x 12” 3046 x 3580 8" x 10" 2398 x 2932 In “Define new” Do not modify/add Select only Delete only Film sheet formats, Landscape Number of pixels [columns x rows] 14" x 17" 5260 x 4268 14” x 14” 4294 x 4268 11" x 14" 4306 x 3327 10” x 12” 3644 x 2970 8" x 10" 2996 x 2322 Medium type Blue film No Film destination Processor Yes Color appearance Gray scale 8 bit No 202 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 202 of 260 NOTE Do not modify or add film sizes. Do not modify pixel sizes. Delete film sizes that are not available at the customer site. SCP / hardcopy camera configuration (provided by OEM) 0 Identification Printer Settings Web-Servicetool for Printlink 5 Configuration Parameter: select input channel in "Input Parameter Setup Screen" window: Background Black No Transformation No magnification No Filming properties Display Changes allowed Device type: DICOM Printer (SCP) Device name: DRYPRO 832 Manufacturer: Konica Minolta SW Revision: V1.02R00 (for Printer & DICOM Server) Physical type: Ethernet Card 100 / 1000 Network protocol: TCP/IP DICOM conformance statement: Konica-Minolta, Printlink5-IN, Ver. 1.0 2006.10 Image memory: Printer: 64 MB; DS: 1 GB-RAM Hard disk: Printer: None; DS: 80 GB © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 203 Page 203 of 260 Configuration LUT: select input channel in "LUT Setup Screen" window: Content Printer Setting Value Input Channel CT_hostname Number of Copies 1 Print priority LOW Film destination BIN_1 Film orientation PORTRAIT Magnification Type CUBIC (checkbox selected) Smooth Type 7 (checkbox selected) Border density BLACK Min. Dens. 0.20 Max. Dens.: 3.00 Trim: NO Config. Information KC_LUT=1 (checkbox selected) Density 0 Contrast 0 Flip NORMAL Polarity NORMAL Medium type BLUE FILM Film Size ID 14" X 17" 204 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 204 of 260 Content Printer Setting Value Input Channel CT_hostname LUT No 1 Display Mode 16Step - Density Drag Mode One Illumination 2000 Refl. Ambient 10 Basic Pattern (linear LUT): Previous Setting 1=20 / 2=39 / 3=57 / 4=76 / 5=95 / 6=113 / 7=132 / 8=151 / 9=169 / 10=188 / 11=207 / 12=225 / 13=244 / 14=263 / 15=281 / 16=300) Test Image Convert P-Value Convert Polarity NORMAL Configuration Maintenance Host name LENOVO-0B9651EF IP address xxx.xxx.xxx.xx AE Title SCP PLNK5 AE Title SCU PLNK5 Port No. 104, 6000, 5200 select input channel in "Printlink 5 Maintenance" window: Input Channel 4 Input Name CT_hostname SCU IP-Adr. xxx.xxx.xxx.xx SCU AET title PR_hostname Protocol Name DICOM PRINT IN Maker KonicaMinolta (1.03) Model RS "double-click" Ch4, SOM64B Channel Name CT_hostname Default Channel (checkbox deselected) Protocol Name DICOM PRINT IN Default Format 1x1 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 205 Page 205 of 260 IP Adr./H. Name xxx.xxx.xxx.xx AE Title SCU PR_hostname Common Input ... ("not relevant for printing") DRYPRO 832 Output Setup: Luminance Conversion ON Border Size CT/MRI Format Type EVEN Pat.Name Stamp Type OFF DICOM PRINT IN N-Event Port No. 0 Empty Notice LV Standard (checkbox selected) Error Level M/M Abort Max PDU 64 Upper Stamp Use OFF Printlink 5 Maintenance IMAGER: "double click" Imager Ch1 DPRO832 Imager Output channel setup screen Channel Name DPRO832 Protocol Name DICOM PRINT OUT IP-Adr./Hostname: Localhost DRYPRO832 IP-Adr. xxx.xxx.xxx.xx AET-SCP KC_DRO4_P001 Port No 63101 Common Output Connect Imager DRYPRO832 Output Pixels 12bit Convert LUT ON Stretch Base No Stretch Stretch Mode BiLinear Content Printer Setting Value 206 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 206 of 260 Error / warning messages (examples) Warning Out ON Layout DcmPrtLayOut832.ini Output Name ASCII + KANJI + KANA Output Image Color Grayscale Study Output Order Normal Annotation Box Not send Calculate Sampling Pitch (checkbox deselected) Imager Default Setting: Default Film Size 1 14x17 Def. Media Type 1 BLUE FILM Def. Film Type 2 11x14 Def. Media Type 2 BLUE FILM Action that results in cam- era error mes- sages Printer messages Message displayed on SCU Defined DCS (*1) Sent by SCP (*2) Film Jam FILM JAM FILM JAM Film jam Open cover and no film is printing COVER OPEN Normal * "nothing is displayed, no film is printed, all films are stored in the camera. After closing the cover all stored films were printed out. 10"x12" film Sup- ply empty EMPTY 10x12 BLUE EMPTY 10x12 BLUE 10x12 blue film supply empty Switch off cam- era but Konica DICOM Server is running PRINTER DOWN PRINTER DOWN Camera down Content Printer Setting Value © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 207 Page 207 of 260 Image Quality and Optical Density 0 No specific parameter available. Real size scaling Send a film with a size which is not inserted in camera (14"x17", 8"x10" inserted, 10"x12" is sent) not defined ELEC SWERROR ** Camera software problem - Queue stopped. (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality * In case of "Camera cover open", no message is displayed. If the camera is ready, jobs are queued only and not printed. ** If a film is not inserted and configured in the camera server, the queue is stopped with a camera software problem. This job must be deleted in the camera queue. Action that results in cam- era error mes- sages Printer messages Message displayed on SCU Defined DCS (*1) Sent by SCP (*2) Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 390.0 391.5 0.38 14" x 17" Landscape X 410.0 412.0 0.49 Y 320.0 320.5 0.16 14" x 14" Portrait X 300.0 301.0 0.33 Y 300.0 301.0 0.33 14" x 14" Landscape X 300.0 301.0 0.33 Y 300.0 301.0 0.33 11" x 14" Portrait X 250.0 250.0 0.00 Y 320.0 321.0 0.31 11" x 14" Landscape X 330.0 331.0 0.30 Y 250.0 250.5 0.20 208 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 208 of 260 10” x 12” Portrait X 230.0 230.0 0.00 Y 270.0 271.0 0.37 10” x 12” Landscape X 270.0 271.0 0.37 Y 220.0 220.5 0.23 8" x 10" Portrait X 170.0 170.0 0.00 Y 220.0 221.0 0.45 8" x 10" Landscape X 230.0 231.0 0.43 Y 170.0 170.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 209 Page 209 of 260 Konica Minolta DryPro 793 6.1 General information 0 Block diagram Fig. 27: Available film sizes Format Release status Film type Medium type 14" x 17" Portrait Yes DRYPRO SD-P Blue-based Landscape Yes DRYPRO SD-P Blue-based 14" x 14" Portrait Yes DRYPRO SD-P Blue-based Landscape Yes DRYPRO SD-P Blue-based 11" x 14" Portrait Yes DRYPRO SD-P New Blue-based Landscape Yes DRYPRO SD-P New Blue-based 10" x 12" Portrait Yes DRYPRO SD-P Blue-based Landscape Yes DRYPRO SD-P Blue-based 8" x 10" Portrait Yes DRYPRO SD-P Blue-based Landscape Yes DRYPRO SD-P Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 210 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 210 of 260 Performance and Connections Associations Maximum number of associations supported: 32 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE The minimum density command is not supported. The mini- mum density value is the value of the fog on the film. Known Effects n.a. SCU / Modality Software Configuration 0 Time 105 sec. Application Entity Properties Display Changes allowed AE Title DPRO793 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec. file name) konicaDryPro793_largeB No DICOM Node Konica793 Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 211 Page 211 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes that are not available at the customer site. Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 87.5 x 87.5 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 3902 x 4668 14" x 14" 3902 x 3799 11" x 14" 3044 x 3799 10” x 12” 2745 x 3219 8" x 10" 2160 x 2643 In “Define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 4725 x 3834 14" x 14" 3856 x 3834 11" x 14" 3868 x 2988 10” x 12” 3275 x 2677 8" x 10" 2699 x 2092 Medium type Blue film No Film destination Processor Yes Color appearance Gray scale 8 bit No Background Black No Transformation No magnification No 212 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 212 of 260 SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Printer settings The configuration has to be performed via the printer keypad. Konica Service has to install the modality name so that the printer settings can be assigned to this name. Switch to Service mode Select "Print" Mode Device type: DICOM Printer (SCP) Device name: DRYPRO 793 Manufacturer: Konica Minolta Medical & Graphics, Inc. SW Revision: V1.00R05 Physical type: Ethernet 10 base-T / 100 base-TX / 1000 base-T Network protocol: TCP/IP DICOM Conformance Statement: Ver.1.02, 2005.02 Image memory: 512 MB Hard disk: 80 GB Setting: Print Setting for CT modality Value LUT NO LUT1: LINEAR DENSITY 0 CONTRAST 0 SMOOTHING 7 MAX DENSITY 300 MIN DENSITY 20 LUMINOUS INTENSITY 2000 AMBIENT LIGHT 10 ROTATION OFF SORTER 1 ORIENTATION PORTRAIT IMAGE POLARITY POSITIVE © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 213 Page 213 of 260 BORDER BLACK TRIM ON/OFF OFF S T A M P TIME/DATE (Not selected) COPY NO. (Not selected) SCU ID/PAGE NO. (Not selected) STAMP MESSAGE (Not selected) PATIENT ID / NAME (Not selected) PATIENT DATA ASCII (Not selected) STAMP CONTENT (EMPTY) Setting: Print Setting for CT modality Value STAMP POSITION EDGE ENHANCE OFF BORDER SIZE CT/MRI EXPANSION CHARACTER OFF MANAGE INFO. PRINT ON REQ.IMAGESIZE EFFECTIVE REQ:BEHAVIOR DECIMATE INTEGRAL MULTIPLE RATIO 2 P VALUE RECEPTION OFF FORMAT EVEN STANDARD DMIN/DMAX DICOM Setting: Print Setting for CT modality Value 214 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 214 of 260 Select “Service 1” Mode D I C O M P r i o r i t y DEFAULT LUT (Not selected) SMOOTH (Not selected) DENSITY MAX (Not selected) DENSITY MIN (Not selected) POLARITY (Not selected) ORIENTATION (Not selected) TRIM (Not selected) BORDER (Not selected) SORTER (Not selected) Setting: SCU SETUP for CT modality Value CHANNEL USE ON SCU NAME CT-hostname IP ADDRESS xxx.xxx.xxx.xxx HOST NAME CT-hostname PORT NUMBER 104 AE TITLE PR_hostname ERROR LEVEL STANDARD SIZE TYPE CHECK ON ENFORCE SPECIFIC FILM OFF STANDARD MAGAZINE 14x17B EMPTY NOTICE SIZE TYPE 14x17B ON SIZE TYPE 8x10B ON SIZE TYPE 10x12B ON © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 215 Page 215 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available. Real size scaling Action that results in cam- era error mes- sages Printer messages Message displayed on SCU Defined DCS (*1) Sent by SCP (*2) Switch to service mode CHECK PRINTER CHECK PRINTER Check camera 14x17 Magazine empty EMPTY 14x17 BLUE EMPTY 14x17 BLUE 14x17 blue film supply empty Front door open CHECK PRINTER CHECK PRINTER Check camera (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.5 0.15 Y 390.0 390.0 0.00 14" x 17" Landscape X 400.0 400.0 0.00 Y 320.0 321.0 0.31 14" x 14" Portrait X 330.0 330.5 0.15 Y 320.0 320.0 0.00 14" x 14" Landscape X 330.0 330.0 0.00 Y 320.0 320.5 0.16 11" x 14" Portrait X 250.0 250.0 0.00 Y 320.0 320.5 0.16 11" x 14" Landscape X 330.0 330.5 0.15 Y 250.0 250.0 0.00 10” x 12” Portrait X 230.0 230.0 0.00 Y 270.0 270.5 0.19 216 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 216 of 260 10” x 12” Landscape X 270.0 270.5 0.19 Y 220.0 220.0 0.00 8" x 10" Portrait X 170.0 170.0 0.00 Y 220.0 220.5 0.23 8" x 10" Landscape X 230.0 230.0 0.00 Y 180.0 180.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 217 Page 217 of 260 Konica Minolta DryPro 771 6.2 General information 0 Block diagram Fig. 28: Available film sizes Format Release status Film Type Medium type 14" x 17" Portrait Yes DRYPRO SD-P Blue-based Landscape Yes DRYPRO SD-P Blue-based 14" x 14" Portrait Yes DRYPRO SD-P Blue-based Landscape No No No 11" x 14" Portrait Yes DRYPRO SD-P New Blue-based Landscape Yes DRYPRO SD-P New Blue-based 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 218 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 218 of 260 Performance and Connections Associations Maximum number of associations supported: 16 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE 14INX14IN landscape not supported by camera. Known Effects n.a. SCU / Modality Software Configuration 0 Time 112 sec. Application Entity Properties Display Changes allowed AE Title DP771 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) konicaDyPro771_largeB No DICOM Node KonicaDP771 Yes © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 219 Page 219 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 78.6 x 78.6 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4350 x 5202 14" x 14" 4350 x 4236 11" x 14" 3384 x 4236 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5318 x 4236 11" x 14" 4310 x 3282 Medium type Blue film No Film destination Processor Yes Color appearance Grayscale 8 bit No Background Black No Transformation No magnification No Device type: DICOM Printer (SCP) Device name: DRYPRO MODEL 771 Manufacturer: KonicaMinolta SW Revision: V1.00R03 Physical type: RJ45 220 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 220 of 260 Printer settings The configuration has to be performed via the printer keypad. Konica service has to install the modality name and assign it to a channel number. For this camera validation, the modality name "specific Modality name" is installed and assigned to channel: "CH3". Use Maintenance Mode to view/modify Print Server Configuration. Select U30 Print Cond. Select CH3 "specific modality name" Enter Network protocol: DICOM, TCP/IP DICOM Conformance Statement: Vers. 1.00, Sep.01. 2003 Image memory: 128 MB / Standard Hard disk: 80 GB / Standard Device type: DICOM Printer (SCP) © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 221 Page 221 of 260 Exit Select U90 - Password Enter INPUT PASSWORD Enter Select U80 Service Mode S00 DICOM SCU displayed Select CH3 "specific modality name" Enter Variable name Content LUT NO 1 LINEAR DENSITY 0 CONTRAST 0 SMOOTHING 2 MAX DENSITY 300 MIN DENSITY 20 ORIENTATION PORTRAIT IMAGE POLARITY POSI TRIM ON/OFF Off BORDER Black ILLUMINATION 2000 AMBIENT LIGHT 10 222 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 222 of 260 Exit Select S30 DICOM PRIORITY Select CH3 "specific modality name" Enter Exit Select S20 Print Cond. Select CH3 "specific modality name" Enter S21 STAMP SELECT Variable name Content CHANNEL USE ON SCU NAME CT-hostname N-EVENT PORT NO BORD=0 IP ADDRESS xxx.xxx.xxx.xxx AE TITLE PR_hostname HOST NAME CT-hostname BORDER SIZE REGIUS FILM SIZE TYPE NO CHECK EMPTY NOTICE ON DICOM ERROR LEVEL STANDARD FRAME LAYOUT EVEN Dmax/Dmin DICOM P-VALUE RCV OFF Variable name Content DEFAULT LUT DICOM SMOOTH DICOM DMAX DICOM DMIN DICOM POLARITY DICOM ORIENTATION DICOM TRIM DICOM BORDER DICOM © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 223 Page 223 of 260 Exit Data was changed Save the data? Yes Enter Exit Error / Warning Messages (examples) Variable name Content TIME/DATE OFF Copy no. OFF Patient ID OFF SCU ID / Page OFF STAMP MESSAGE OFF STAMP MESSAGE STAMP DIRECTION LOWER YEAR/FORMAT YY MONTH/FORMAT TEXT DATE/FORMAT TIME+DATE REQ.IMAGESIZE EFFECTIVE EXPANSION CHAR OFF EDGE ENHANCE OFF REQ:BEHAVIOR DECIMATE FLIP ON/OFF OFF Action that results in camera error mes- sages Printer messages Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP 14x17 Magazine empty EMPTY 14x17 BLUE EMPTY 14x17 BLUE 14x17 blue film supply empty Front door open COVER OPEN CHECK PRINTER Check camera Switch to service mode n.a. CHECK PRINTER Check camera 224 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 224 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Action that results in camera error mes- sages Printer messages Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.5 0.15 Y 400.0 401.0 0.25 14" x 17" Landscape X 410.0 411.0 0.24 Y 320.0 320.5 0.16 14" x 14" Portrait X 330.0 330.0 0.00 Y 320.0 321.0 0.31 14" x 14" Landscape X No No No Y No No No 11" x 14" Portrait X 250.0 250.0 0.00 Y 320.0 320.5 0.16 11" x 14" Landscape X 330.0 330.5 0.15 Y 250.0 250.5 0.20 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 225 Page 225 of 260 Konica DryPro 751/752 6.3 General information 0 Block diagram Fig. 29: Available film sizes Format Release status Film Type Medium type 14" x 17" Portrait Yes DRYPRO SD-P New Blue-based Landscape Yes DRYPRO SD-P New Blue-based 14" x 14" Portrait Yes DRYPRO SD-P Blue-based Landscape Yes DRYPRO SD-P Blue-based 11" x 14" Portrait Yes DRYPRO SD-P New Blue-based Landscape Yes DRYPRO SD-P New Blue-based 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available 226 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 226 of 260 Performance and Connections Associations Maximum number of associations supported: 16 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). Known Effects n.a. SCU / Modality Software Configuration 0 Time 98 sec. Application Entity Properties Display Changes allowed AE Title DPRO752 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) konicaDryPro752 No DICOM Node DPRO752 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 227 Page 227 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Pixel Size [1/1000 mm] 80.0 x 80.0 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4272 x 5112 14" x 14" 4272 x 4162 11" x 14" 3336 x 4162 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5224 x 4162 14" x 14" 4272 x 4162 11" x 14" 4274 x 3224 Medium type Blue film No Film destination Processor Yes Color appearance Grayscale 8 bit No Background Black No Transformation No magnification No Filming properties Display Changes allowed Device type: DICOM Printer (SCP) Device name: DRYPRO 752 Manufacturer: Konica SW Revision: V1.00R7 Physical type: Ethernet RJ45 10/100 Base TX Network protocol: TCP/IP 228 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 228 of 260 Printer settings DICOM Conformance Statement: V 1.03, Jun.18.2003 Image memory: 256 MB RAM Hard disk: 20 GB File Name Parameters Content Maintenance 1/3 Print Condition CT host name LUT LINEAR DENSITY 0 CONTRAST 0 SMOOTH TYPE 7 MAX DENSITY 300 MIN DENSITY 020 L0 0 La 0 SORTER BIN 01 ORIENTATION Portrait POLARITY Posi TRIM Off BORDER Black FLIP Off STAMP SELECT DATE TIME No Copy no. No Patient ID No SCU ID/page no. No Device type: DICOM Printer (SCP) © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 229 Page 229 of 260 STAMP MESSAGE No STAMP DIRECTION Stamp position in graphic: top Maintenance 2/3 SERVICE n.a. DICOM SCU CT hostname SCU SETUP n.a. SCU CH USE ON SCU NAME CT hostname N-EVENT PORT NO 0 IP ADDRESS xxx.xxx.xxx.xxx AE TITLE PR_hostname HOST NAME CT hostname SIZE TYPE CHECK ON BORDER SIZE REGIUS EMPTY NOTICE n.a. 14x17 B ON 14x14 B ON EDGE ENHANCE ON FRAME LAYOUT CENTER DICOM ERROR LEVEL STANDARD DEFAULT Dmax/Dmin DICOM Magnification 02 File Name Parameters Content 230 Specific Camera Information - Konica Minolta SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 230 of 260 Error / Warning Messages (examples) Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Action that results in camera error mes- sages Printer messages Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Camera switched off n/a TCP init error, tim- eout Connection to camera is not available 14x17 Magazine empty EMPTY 14x17 BLUE EMPTY 14x17 BLUE 14x17 blue film supply empty (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 331.0 0.30 Y 380.0 381.0 0.26 14" x 17" Landscape X 400.0 401.0 0.25 Y 320.0 321.0 0.31 14" x 14" Portrait X 330.0 331.0 0.30 Y 320.0 321.0 0.31 14" x 14" Landscape X 330.0 331.0 0.30 Y 320.0 321.0 0.31 11" x 14" Portrait X 250.0 251.0 0.40 Y 320.0 321.0 0.31 11" x 14" Landscape X 330.0 331.0 0.30 Y 240.0 241.0 0.42 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information - Konica Minolta 231 Page 231 of 260 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 232 Specific Camera Information Sony SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 232 of 260 7- 7Specific Camera Information Sony Sony UP-DF 550 0 General information 0 Block diagram Fig. 30: Available film sizes Performance and Connections Associations Maximum number of associations supported: 8 Format Release status Film Type Medium type 14" x 17" Portrait Yes UPT-517BL Blue-based Landscape Yes UPT-517BL Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait Yes UPT-514BL Blue-based Landscape Yes UPT-514BL Blue-based 10" x 12" Portrait Yes UPT-512BL Blue-based Landscape Yes UPT-512BL Blue-based 8" x 10" Portrait Yes UPT-510BL Blue-based Landscape Yes UPT-510BL Blue-based Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information Sony 233 Page 233 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, format 4x5, Copies=1, default center/width, magnification type none. The optimal connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Horizontal line structure visible with all film sizes. NOTE Background of film is always white. Known Effects NOTE The UPT-517BL film type requires a specific densitometer characteristic. Density measurements using the X-Rite 301 densitometer are only possible if special optics 301-34SO are installed on the X-Rite 301 and calibrated as described in the X-Rite letter. NOTE If a film size is sent to the camera and the required film size is not inserted in the camera, then nothing is displayed, nei- ther in Somaris nor on the camera display. Jobs stay in the queue until the required magazine is inserted. If an attempt is made to switch off the camera before all jobs are printed, the unprinted jobs are displayed - and the camera is not switched off. SCU / Modality Software Configuration 0 Time 112 sec. Application Entity Properties Display Changes allowed AE Title UPDF550 Yes Port number 104 No 234 Specific Camera Information Sony SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 234 of 260 HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) SonyUPDF550 No DICOM Node Sony550 Yes Filming properties Display Changes allowed Hold printed Film Jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 79.4 x 79.4 No Film Sheet Formats, Portrait Number of Pixels [columns x rows] 14" x 17" 4360 x 5232 11” x 14” 3426 x 4286 10” x 12” 3100 x 3630 8” x 10” 2452 x 3004 In “define new” Do not modify/add Select only Delete only Film Sheet Formats, Landscape Number of Pixels [columns x rows] 14" x 17" 5232 x 4360 11” x 14” 4286 x 3426 10” x 12” 3630 x 3100 8” x 10” 3004 x 2452 Medium type Blue film No Film destination Processor No Color appearance Grayscale 8 bit No Background Black Yes Transformation No magnification No © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information Sony 235 Page 235 of 260 NOTE Do not modify and/or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / Hardcopy Camera Configuration (provided by OEM) 0 Identification Manufacturer / device type: DICOM Printer (SCP) Device name: Film Station UP-DF 550 Manufacturer: SONY SW Revision: (for VA20) (for VA26) MA-FW: 1.05 TST7; DICOM: V3.21; DR-FW: V1.01; CT-FW: V1.00, ICTAC: V1.00; IDMAC: V25.0 MA-FW: 1.07 TST1; DICOM: V3.21; DR-FW: V1.01; CT-FW: V1.00, ICTAC: V1.00; IDMAC: V25.0 Physical Interface: Ethernet 10/100 base T/Tx Network protocol: TCP/IP DICOM Conformance Statement: Sony UP-DF550, Rev. 1.1, Feb.19, 2007 Image memory: 3.5 GB Hard disk: No 236 Specific Camera Information Sony SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 236 of 260 Printer settings File Name Content Remarks No file; Keypad settings, press "Menu” Information> IP ADDRESS xxx.xxx.xxx.xxx TOTAL PRINTS Network address No file; Keypad settings, press "Menu" PRINT Quality> SELECT GAMMA /SL32_14C/ [EXEC] SHARPNESS OFF PATTERN PRINT 1: 14x17 [EXEC] SELECT POINT 95%.....[25%] SELECT POINT 5%.....[75%] SAVE GAMMA [EXEC] Gamma table 8 (Linear LUT) No file; Keypad settings, press "Menu" CALIBRATION> FULL RANGE CAL 1: 14x17 [EXEC] AUTO CALIBRATION [On/Off] CAL RESET 14x17 [EXEC] © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information Sony 237 Page 237 of 260 Error / Warning Messages (examples) No file; Keypad settings, press "Menu" GAMMA SEL> DEFAULT14x17 /SL32_14C/ DEFAULT11x14 /SL32_14C/´ DEFAULT10x12 /SL32_14C/ DEFAULT 8x10 /SL32_14C/ Linear LUT Linear LUT Linear LUT Linear LUT No file; Keypad settings, press "Menu" SYSTEM SETTINGS> NETWORK SETTINGS> IP ADDRESS xxx.xxx.xxx.xxx SUBNETMASK xxx.xxx.xxx.xxx DEFAULT Gateway xxx.xxx.xxx.xxx STRICT SIZE .. ON SAVE SETTINGS >EXEC Network address Subnet mask Default Gateway ON = job stored if film size is not available Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Cover or door of camera open COVER OPEN COVER OPEN Camera cover, drawer or door open Supply magazine not inserted NO SUPPLY MGZ NO SUPPLY MGZ Film supply not avail- able Supply magazine empty EMPTY 14X17 BLUE EMPTY 14X17 BLUE 14x17 blue film sup- ply empty Film jam FILM JAM FILM JAM Film jam File Name Content Remarks 238 Specific Camera Information Sony SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 238 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling Magazines with 14x17 and 8x10 films inserted, a job with film size 11x14 is sent Nothing NORMAL Nothing is displayed, neither in Somaris nor on the camera display. Jobs stay in queue until the 11x14 magazine is inserted. If an attempt is made to switch off the cam- era before all jobs are printed, the unprinted jobs are displayed - and the camera is not switched off. (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 320.0 320.0 0.00 Y 400.0 399.5 0.12 14" x 17" Landscape X 400.0 399.5 0.12 Y 320.0 320.0 0.00 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X 260.0 260.0 0.00 Y 320.0 319.2 0.25 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information Sony 239 Page 239 of 260 11" x 14" Landscape X 320 319.0 0.31 Y 260.0 260.0 0.00 10” x 12” Portrait X 240.0 239.8 0.08 Y 260.0 259.5 0.19 10” x 12” Landscape X 280.0 279.5 0.18 Y 220.0 220.0 0.00 8" x 10" Portrait X 180.0 180.0 0.00 Y 220.0 218.8 0.55 8" x 10" Landscape X 220.0 218.8 0.55 Y 180.0 180.0 0.00 Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 240 Specific Camera Information Sony SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 240 of 260 Sony UP-DF 500 7.1 General Information 0 Block Diagram Fig. 31: Available Film Sizes Performance and Connections Associations Maximum number of associations supported: 8 Format Release status Film type Medium type 14" x 17" Portrait Yes UPT-517BL Blue-based Landscape Yes UPT-517BL Blue-based 14" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 11" x 14" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 10" x 12" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. 8" x 10" Portrait n.a. n.a. n.a. Landscape n.a. n.a. n.a. Other n.a. n.a. n.a. Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information Sony 241 Page 241 of 260 Performance Use medical image 4 of patient "Reference Images", maximum film size, positive image, 4x5 format, Copies=1, default center/width, magnification type none. The optimum connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Line structure is visible. 3% modulation is visible with a lense only. NOTE The UPT-517BL film type requires a specific densitometer characteristic. Density measurements using the X-Rite 301 densitometer are only possible if special optics 301-34SO are installed on the X-Rite 301 and calibrated as described in the X-Rite letter. Known effects n.a. SCU / modality software configuration 0 Time 133 sec. Application Entity Properties Display Changes allowed AE Title UPDF500 Yes Port number 104 No HC Device / General settings Display Changes allowed Type DICOM printer No Class (Printer spec file name) SonyUPDF500 No DICOM Node Sony UP_DF500 Yes 242 Specific Camera Information Sony SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 242 of 260 NOTE Do not modify or add film sizes. Do not modify pixel sizes. Delete film sizes not available at the customer site. SCP / hardcopy camera configuration (provided by OEM) 0 Identification Filming properties Display Changes allowed Hold printed film jobs 10 Yes Min. density 20 Yes Pixel Size [1/1000 mm] 79.4 x 79.4 No Film sheet formats, Portrait Number of pixels [columns x rows] 14" x 17" 4224 x 5060 In “define new” Do not modify/add Select only Delete only Film sheet formats, Landscape Number of pixels [columns x rows] 14" x 17" 5060 x 4224 Medium type Blue film No Film destination Processor No Color appearance Gray scale 8 bit No Background Black Yes Transformation No magnification No Manufacturer / device type: DICOM Printer (SCP) Device name: Film Station UP-DF 500 Manufacturer: SONY SW Revision: (for VA20) (for VA26) MA: 3.04 DR: 3.03 CT: 1.03 IDMAC: 25.0 DICOM: 01.67 MA: 4.00 DR: 4.02 CT: 2.00 IDMAC: 25.0 ICTAG: 1.00 DICOM: 3.21 Physical interface: Ethernet (RJ45) © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Camera Information Sony 243 Page 243 of 260 Printer Setting Error / warning messages (examples) Network protocol: TCP/IP DICOM conformance state- ment: Rev. 2.0, May 21, 2003. Image memory: 12 GB Hard disk: 20 GB File Name Content Remarks No file; Keypad settings, press "Menu" Information> IP ADDRESS xxx.xxx.xxx.xxx Network address No file; Keypad settings, press "Menu" PRINT Quality> SHARPNESS OFF GAMMA SEL Default GAMMA SL32_14C Interpolation Linear LUT No file; Keypad settings, press "Menu" Density ADJ> SELECT POINT 95% ...[25] 95%...[9] 5 % ...[75] (for MA3.04) (for MA4.00) Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Cover or door of camera open COVER OPEN COVER OPEN Camera cover, drawer or door open Supply magazine not inserted NO SUPPLY MGZ NO SUPPLY MGZ Film supply not avail- able Supply magazine empty EMPTY 14X17 BLUE EMPTY 14X17 BLUE 14x17 blue film sup- ply empty Film jam FILM JAM FILM JAM Film jam Manufacturer / device type: DICOM Printer (SCP) 244 Specific Camera Information Sony SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 244 of 260 Image Quality and Optical Density 0 No specific parameter available Real Size Scaling (*1) refer to all messages in the DCS of the hardcopy camera (*2) refer to all messages in the DCS of the modality Camera warning or error messages Printer message Message displayed on SCU (*2) Defined DCS (*1) Sent by SCP Film size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % 14" x 17" Portrait X 330.0 330.0 0.00 Y 380.0 378.5 0.39 14" x 17" Landscape X 390.0 388.5 0.38 Y 320.0 320.0 0.00 14" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 14" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 11" x 14" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 10” x 12” Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Portrait X n.a. n.a. n.a. Y n.a. n.a. n.a. 8" x 10" Landscape X n.a. n.a. n.a. Y n.a. n.a. n.a. © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Epson 245 Page 245 of 260 8- 8Specific Printer Information Epson Epson AcuLaser C 4200 0 General information 0 Block diagram Fig. 32: Available film sizes Performance Use medical color image A4, positive image, format 3x4, copies=1, default center/width. The modality has to be configured to CTLUT and the respective PS LUT file for this printer. The optimum connection (point to point) was used. Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). Format Release status Paper Type Medium type A4 Yes Business Laser Copier Paper 80g/m 2 Paper Letter Yes Business Laser Copier Paper 80g/m 2 Paper Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available Time 58 sec 246 Specific Printer Information Epson SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 246 of 260 NOTE Paper print-outs are not allowed for medical diagnoses. NOTE 510K premarket notification/approval not available. NOTE The Adobe printer driver with the printer-specific description file has to be used. The paper printer is not linear in the grayscale image print-out. As a result, the special LUT "EPSON_C4200_correction.lut" in the configuration of the PSLUT files has to be used to optimize the image quality of the print-out. NOTE Color graphic lines and markers (arrows) are difficult to iden- tify on paper. For CT applications (e.g. calcium scoring), use the report of the applications to print out the result images. Known Effects NOTE Line structure visible on grey field. NOTE Saturated colors do not have any contrast (approx 3 steps of a 17-step test image). Smooth transitions from black to a sat- urated color are not continuous. Effective resolution on the Xerox Business Paper is only approx. 200 DPI. Displacement of the primary colors visible (light vertical shift in portrait ori- entation) Printer Configuration 0 Only the configuration has been performed with the generic “winsteng.exe” and the post- script description file “epalc420ppd” version. NOTE Version of Adobe Driver: V 5.2 Modality Configuration (Postscript Driver) 0 The default setting of the postscript driver has to be optimized at the modality site. These settings are: © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Epson 247 Page 247 of 260 Printer --> Properties --> Device Settings: AdobePS EPSON AL-C4200 PS3 Device Settings --> Form To Tray Assignment. --> MP Tray: Letter --> Cassette 1: A4 --> Cassette 2: Not Available --> Cassette 3: Not Available --> Cassette 4: Not Available --> Manual Feed 1st Page: Letter --> Manual Feed Each Page: Letter --> Font Substitution Table --> Arial: Helvetica --> Courier New: Courier --> Symbol: Symbol --> Times New Roman: Times --> xxxx: <Don’t Substitute> --> xxxx: For all other fonts of the substitu- tion table --> Available PostScript Memory: 249 KB --> Output Protocol: ASCII --> Send CTRL-D Before Each Job: No --> Send CTRL-D After Each Job: Yes --> Convert Gray Text to PostScript Gray: No --> Convert Gray Graphics to PostScript Gray: No --> Add Euro Currency Symbol To PostScript Fonts: No --> Job Timeout: 30 seconds --> Wait Timeout: 40 seconds --> Minimum Font Size to Downloads as Outline: 100 pixel(s) --> Maximum Font Size to Download as Bitmap: 600 pixel(s) --> Installable Options 248 Specific Printer Information Epson SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 248 of 260 --> Installed Memory: 128 MB --> Lower Cassette Unit: None Printer --> Printing Preferences --> Advanced: (*1) and Printer --> Properties --> Advanced --> Printing Defaults --> Advanced:(*2) AdobePS EPSON AL-C4200 PS3 Advanced Document Settings --> Paper/Output --> Paper Size: A4 --> Copy Count: 1 Copy --> Graphic --> Print Quality: Quality --> Image Color Management --> --> ICM Method: ICM Disabled --> --> ICM Intent: Pictures --> Scaling: 100% --> True Type Font: Substitute with Device Font --> Document Options --> Advanced Printing Features: Enabled --> Postscript Options --> --> PostScript Output Option: Optimize for Speed --> --> True Type Font Download Option: Automatic --> --> PostScript Language Level: 3 --> --> Send PostScript Error Handler: Yes --> --> Mirrored Output: No --> Printer Features Color Model RGB Color Mode Color RGB Color Mode Vivid Color Screen Increase Gradation Pure Black Mode Text Auto Mono Mode Off RITech On © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Epson 249 Page 249 of 260 Hardcopy Printer Identification (provided by OEM) 0 Identification Printer Keypad Settings The default setting of the printer should be used. Error / Warning Messages (examples) Toner Save Mode Off Image Protect Off Start Page Front Rotate by 180° Off (*1/2) Both settings must be identical Device type: Color Laser Printer Device name: AcuLaser C4200 Manufacturer: Epson SW Revision or Firmware Version: OS: 22710 22618 Fonts: 00005208 LAN: 02.20 Number of Input Interface: 3 (Parallel, USB and Network) Physical Interface: Network: 10/100 Base Tx USB: Hi-Speed USB 2.0 Parallel: IEEE 1284 Network protocol: TCP/IP 10/100 Image memory: 128 MB Hard disk: None Connector for Network: RJ45 Documentation: - User Guide (SAP 14403347 ASD 01S 00)- Admin- istrator Guide (SAP 14403347 ASD 02S 00) Action to provide error messages of printer Message displayed on Modality Printer switched off Offline No paper inserted in magazine, some print jobs sent Out of Paper 250 Specific Printer Information Epson SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 250 of 260 Image Quality and Optical Density 0 Optical Density NOTE The PSLUT file has to be configured: “ EPSON_C4200_correction” At this time, no reference values have been defined for paper printers. Densitometer model/type X-Rite 528 was used. For this measurement result, the Xerox Buisness Laser Copier Inkjet Paper was used. It is also recommended to add some additional white paper below the print-out to improve results during the measurement. Before testing the image quality, calibrate the densitometer. Afterwards check the white field of the densitometer in the "paper" mode (dot area). Note the values for V. Top cover of printer is open,some print jobs sent Door open Tray for paper not inserted Out of Paper Action to provide error messages of printer Message displayed on Modality Values of "Paper" & "Sample" mode V Offset of the white field in the "Paper" mode (absolute value) 0.06 Value of the white field for density in the "Solid" mode ( relative value) 0.00 Step Measured Rela- tive Value 1 0.01 2 0.08 3 0.14 4 0.18 5 0.22 6 0.27 7 0.31 8 0.38 9 0.45 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Epson 251 Page 251 of 260 NOTE The PS Printer has to be set to Black&White for this measure- ment Real Size Scaling 10 0.51 11 0.60 12 0.70 13 0.87 14 1.07 15 1.28 16 1.44 17 1.57 Paper size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % A4 Portrait X 160.0 159.5 0.31 Y 280.0 280.0 0.00 A4 Landscape X 280.0 280.5 0.18 Y 160.0 160.0 0.00 Letter Portrait X 200.0 199.5 0.25 Y 240.0 239.5 0.21 Letter Landscape X 240.0 239.5 0.21 Y 160.0 159.5 0.31 Step Measured Rela- tive Value 252 Specific Printer Information Hewlett Packard SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 252 of 260 9- 9Specific Printer Information Hewlett Packard Hewlett Packard Color Laser Jet 4700N 0 General information 0 Block diagram Fig. 33: Available film sizes Performance and Connections Performance Use medical color image A4, positive image, format 3x4, copies=1, default center/width. The modality has to be configured to CTLUT and the respective PS LUT file for this printer. The optimal connection (point to point) was used. Format Release status Paper Type Medium type A4 Yes Business Laser Copier Paper 80g/m 2 Paper Letter Yes Business Laser Copier Paper 80g/m 2 Paper Released: Yes - Film size is available and released Released: No - Film size is available but not released Released: n.a. - Film size is not available Time 23 sec © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Hewlett Packard 253 Page 253 of 260 Restrictions NOTE For HCC-independent restrictions, refer to (Restrictions and known effects / p. 8). NOTE Paper print-outs are not allowed for medical diagnoses. NOTE 510K premarket notification/approval not available. NOTE For pure black&white images the configuration of the driver for the printer should be set to black&white to optimize the image quality on paper. NOTE No resolution (contrast) in the white area between step 1 and 2 of the grayscale image NOTE Color graphic lines and markers (arrows) are difficult to iden- tify on paper. For CT applications (e.g. calcium scoring), use the report of the applications to print out the result images. Known Effects NOTE Resolution of 600DPI not visually reached on the printout. 1-Pixel stripes are smoothed. NOTE Color displacement of the primaries visible on the printout. NOTE Line structure visible on flat fields. NOTE Color gradient from white to a light color is not continuous. NOTE No contrast at saturated colors. NOTE The toner can be smeared off the paper, this lightens the image and affects image quality. 254 Specific Printer Information Hewlett Packard SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 254 of 260 Printer Configuration 0 Only the configuration has been performed with the generic “winsteng.exe” and the “hpmcpd25.ppd” postscript description file version. NOTE Version of Adobe Driver: V 5.2 Modality Configuration (Postscript Driver) 0 The default setting of the postscript driver has to be optimized at the modality site. These settings are: Printer --> Properties --> Device Settings: AdobePS HP Universal PrintingPS Device Settings --> Form To Tray Assignment. --> Printer Auto Select: A4 --> Manual Feed in Tray1: Letter --> Tray 1: Letter --> Tray 2: A4 --> Tray 3: Letter --> Tray 4: Letter --> Tray 5: Letter --> Tray 6: Letter --> Tray 7: Letter --> Tray 8: Letter --> Tray 9: Letter --> Ex Tray (MP5): Letter --> Ex Tray (MP6): Letter --> Ex Tray (MP7): Letter --> Ex Tray (MP8): Letter --> Ex Tray (MP9): Letter --> Ex Tray (MP10): Letter --> Envelope Feeder: Letter --> Font Substitution Table --> Courier New: Courier © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Hewlett Packard 255 Page 255 of 260 --> xxxx: <Don’t Substitute> --> xxxx: For all other fonts of the substitu- tion table --> Available PostScript Memory: 6144KB --> Output Protocol: ASCII --> Send CTRL-D Before Each Job: No --> Send CTRL-D After Each Job: Yes --> Convert Gray Text to PostScript Gray: No --> Convert Gray Graphics to PostScript Gray: No --> Add Euro Currency Symbol To PostScript Fonts: Yes --> Job Timeout: 0 seconds --> Wait Timeout: 300 seconds --> Minimum Font Size to Downloads as Outline: 100 pixel(s) --> Maximum Font Size to Download as Bitmap: 600 pixel(s) --> Installable Options --> Accessory Output Bin: Not Installed --> Printer Memory: 384-494 MB --> Printer Hard Disk: Installed --> Job Storage: Enabled --> Postscript Passthrough: Enabled --> Copier Mode: Disabled --> Automatic Configuration: Off --> HPOutputBinPMLRange: 4-11 --> HPPrnPropResourceData: hpzhl3xr.cab --> HPInstallableHCO: 3000Stacker-C8084 --> HPMOutputBinHCOMap: Auto --> HPMOutputBinHCOPMLMap: 0-0 Printer --> Printing Preferences --> Advanced(*1): and Printer --> Properties --> Advanced --> Printing Defaults --> Advanced(*2): AdobePS HP Universal PrintingPS Advanced Document Settings --> Paper/Output --> Paper Size: A4 256 Specific Printer Information Hewlett Packard SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 256 of 260 --> Copy Count: 1 Copy --> Graphic --> Image Color Management --> --> ICM Method: ICM Disabled --> --> ICM Intent: Pictures --> Scaling: 100% --> True Type Font: Substitute with Device Font --> Document Options --> Advanced Printing Features: Enabled --> Postscript Options --> --> PostScript Output Option: Optimize for Speed --> --> True Type Font Download Option: Automatic --> --> PostScript Language Level: 2 --> --> Send PostScript Error Handler: Yes --> --> Mirrored Output: No --> Printer Features --> --> Orientation Rotated 180 Degrees: Off --> --> PostScriptCustomPageSize: Off --> --> Output Bin: Automatically Select --> --> Stapling Options: None --> --> HPCovers: Other Pages --> --> Print All Text as Black: Disabled --> --> PrintQualityGroup: Best --> --> JRHDInstalled: JRHDOff --> --> HPDocPropResourceData: hpzhl3xr.cab --> --> JRConstraints: JRCHDFull --> --> HPSmartHub: _ --> --> Print Color as Gray: Off (*1/2) Both settings must be identical © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Hewlett Packard 257 Page 257 of 260 Hardcopy Printer Identification (provided by OEM) 0 Identification Printer Keypad Settings The default setting of the printer should be used. Error / Warning Messages (examples) Device type: Color Laser Printer Device name: Color Laser Jet 4700N Manufacturer: Hewlett-Packard SW Revision or Firmware Version: 20051204 46.029.3 Number of Input Interface: 2 (Network and USB 2.0)) Physical Interface: Ethernet and USB-B and IEEE 1284-C-compatible bidirectional parallel interface Network protocol: TCP/IP and Windows USB 2.0 Image memory: 384 MB Hard disk: Yes Connector for Network: RJ 45 / USB-B / Parallel port Documentation: - “Technical Data” EMEA 08/05 5983-2739DEE SAP: 14403335 GDB 01S 00 - "HP Color LaserJet 4700 Operator Manual“ SAP: 14403335 ASD 01S 00 - “Configuration page” (can be printed in the printer`s LCD menu) SAP: 14403335 GDB 02S 00 Action to provide error messages of printer Message displayed on Modality Printer switched off Offline No paper inserted in magazine, some print jobs sent Out of paper Top cover of printer is open, some print jobs sent Door Open Tray for paper not inserted correctly Offline 258 Specific Printer Information Hewlett Packard SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 258 of 260 Image Quality and Optical Density 0 Optical Density NOTE The PSLUT file has to be configured: “ HP_LaserJet4700_linear” At this time, no reference values have been defined for paper printers. Densitometer model/type X-Rite 528 was used. For this measurement result, the Xerox Buisness Laser Copier Inkjet Paper was used. It is also recommended to add some additional white paper below the print-out to improve the results during the measurement. Before testing the image quality, calibrate the densitometer. Afterwards check the white field of the densitometer in the "paper" mode (dot area). Note the values for V. Values of "Paper" & "Sample" mode V Offset of the white field in the "Paper" mode (absolute value) 0.06 Value of the white field for density in the "Solid" mode ( relative value) 0.00 Step Measured Rela- tive Value 1 0.01 2 0.02 3 0.05 4 0.10 5 0.16 6 0.22 7 0.31 8 0.41 9 0.50 10 0.63 11 0.74 12 0.87 13 1.02 14 1.19 15 1.31 © Siemens, 2008 CT00-000.814.30.02.02 SOMATOM Definition 05.09 H WS CS SD CO Specific Printer Information Hewlett Packard 259 Page 259 of 260 NOTE The PS Printer has to be set to Black&White for this measure- ment Real Size Scaling 16 1.54 17 1.92 Paper size / Direction Desired (mm) Measured (mm) Deviation obtained from desired value in % A4 Portrait X 160.0 160.0 0.00 Y 280.0 280.0 0.00 A4 Landscape X 280.0 279.5 0.18 Y 160.0 159.5 0.31 Letter Portrait X 160.0 160.5 0.31 Y 240.0 240.5 0.21 Letter Landscape X 240.0 240.0 0.00 Y 160.0 160.0 0.00 Step Measured Rela- tive Value 260 Changes to Previous Version SOMATOM Definition CT00-000.814.30.02.02 © Siemens, 2008 05.09 H WS CS SD CO Page 260 of 260 10- 10Changes to Previous Version Changes to Previous Version 0 Chapter Section Action 4 Fuji Drypix 4000 Identification updated 4 Fuji Drypix 7000/5000 Identification updated 5 Kodak DryView 6800 Identification updated 7 Sony UP-DF 550 Identification updated Printer setting updated 7 Sony UP-DF 500 Restrictions updated Identification updated Printer setting updated
Copyright © 2024 DOKUMEN.SITE Inc.