CSA-CertifiedProduct-FWMurphy
Comments
Description
CSA International - Certified Product ListingsNew Search Found: 22 Displaying: 1-22 Refine Search Company FW Murphy Prov/State Country OK USA Class 3218-02 Class Description INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers - Auxiliary Devices-For Hazardous Locations INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers - Miscellaneous - For Hazardous Locations INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers-Miscellaneous-For Hazardous Locations-Certified to U.S. Standards VALVES-For Hazardous Locations TIME INDICATING AND RECORDING APPLIANCES-For Hazardous Locations INDUSTRIAL CONTROL EQUIPMENTMiscellaneous Apparatus INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers - Miscellaneous - For Hazardous Locations INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers-Miscellaneous-For Hazardous Locations-Certified to U.S. Standards TEMPERATURE-INDICATING AND REGULATING EQUIPMENT-Other Than Appliance Type INDUSTRIAL CONTROL EQUIPMENTMiscellaneous Apparatus - For Hazardous Locations INDUSTRIAL CONTROL EQUIPMENTMiscellaneous Apparatus-For Hazardous Locations-Certified to U.S. Standards OUTLET BOXES AND FITTINGS-Boxes - For Hazardous Locations PROCESS CONTROL EQUIPMENT-For Hazardous Locations File Number 018709_0_000 FW Murphy OK USA 3218-05 018709_0_000 FW Murphy OK USA 3218-85 018709_0_000 FW Murphy FW Murphy FW Murphy FW Murphy OK OK OK OK USA USA USA USA 3228-01 4878-01 3211-07 3218-05 021357_0_000 027183_0_000 028623_0_000 046304_0_000 FW Murphy OK USA 3218-85 046304_0_000 FW Murphy OK USA 4813-02 046305_0_000 FW Murphy OK USA 3218-06 046306_0_000 FW Murphy OK USA 3218-86 046306_0_000 FW Murphy FW Murphy FW Murphy OK OK OK USA USA USA 4418-02 2258-02 2258-03 046564_0_000 064764_0_000 064764_0_000 PROCESS CONTROL EQUIPMENT Intrinsically Safe and Non-Incendive Systems For Hazardous Locations PROCESS CONTROL EQUIPMENT-For Hazardous Locations - Certified to US 064764_0_000 FW Murphy OK USA 2258-82 http://directories.csa-international.org/...rovState=&txtCountry=USA&txtFile=&txtMajorClass=&txtMinorClass=&txtClassDesc=&txtKeyword=[06-Jan-11 13:18:23] CSA International - Certified Product Listings Standards FW Murphy OK USA 2258-83 PROCESS CONTROL EQUIPMENTIntrinsically Safe and Non-Incendive-SystemsFor Hazardous Locations-Certified to U.S. Standards INDUSTRIAL CONTROL EQUIPMENTMiscellaneous Apparatus INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers - Miscellaneous INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers-Miscellaneous-Certified to U.S. Standards INDUSTRIAL CONTROL EQUIPMENTMiscellaneous Apparatus - For Hazardous Locations INDUSTRIAL CONTROL EQUIPMENTMiscellaneous Apparatus-For Hazardous Locations-Certified to U.S. Standards PROCESS CONTROL EQUIPMENT-For Hazardous Locations 064764_0_000 FW Murphy FW Murphy FW Murphy OK OK OK USA USA USA 3211-07 3211-06 3211-86 069293_0_000 078646_0_000 078646_0_000 FW Murphy OK USA 3218-06 078646_0_000 FW Murphy OK USA 3218-86 078646_0_000 Murphy Power Ignition CA USA 2258-02 202340 http://directories.csa-international.org/...rovState=&txtCountry=USA&txtFile=&txtMajorClass=&txtMinorClass=&txtClassDesc=&txtKeyword=[06-Jan-11 13:18:23] Certification Record CUSTOMER Murphy Power Ignition 6302 Riverdale St, San Diego CA 92120 USA Class I, Div. 2, Groups B, C and D: Ignition Controllers, rated 20 to 30V dc, 3A max with the following models: - MPI-8, MPI-8-SS, MPI-8D, MPI-8D-SS - MPI-16, MPI-16-SS, MPI-16D, MPI-16D-SS - MPI-32, MPI-32-SS, MPI-32D, MPI-32D-SS ITX-230RM Ignition Coil, - nominal primary voltage 230V (250V max) - nominal output voltage 27,600V (30,000V max) ITX-150-12 Integral Ignition Coil, (12 in long) - nominal primary voltage 150V (200V max) - nominal output voltage 30,000V (35,000V max) ITX-150-6 Integral Ignition Coil, (6 in long) - nominal primary voltage 150V (200V max) - nominal output voltage 30,00V (35,000V max) ITX-200RM Shielded Remote Mount Ignition Transformer. - nominal primary voltage 200V. - nominal output voltage 44kV. ITX-170-6, ITX-170-10 and ITX-170-12 Ignition Coils. - nominal primary voltage 150V dc. - nominal output voltage 30kV. ITX -250-12 Ignition Coil - nominal primary voltage 250V. - nominal output voltage 42.8kV. /jj Copyright © 2011 CSA International. All rights reserved. CLASS 2258-02 PROCESS CONTROL EQUIPMENTFor Hazardous Locations FILE 202340 Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/202340-2258-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:50:18] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS FILE 078646_0_000 3218-86 INDUSTRIAL CONTROL EQUIPMENT-Miscellaneous ApparatusFor Hazardous Locations-Certified to U.S. Standards Refer to Class Description for program details Class I, Div 1, Groups C and D; Class II, Div 1 Groups F and G: Series LM300 oil level maintainers, Models LM301EX through LM305EX. Switch contacts rated 11 amps and 1/3 hp, 125, 250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated. Ambient Temperature less than 40C. Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3218-86.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:47:51] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS FILE 078646_0_000 3218-06 INDUSTRIAL CONTROL EQUIPMENT-Miscellaneous Apparatus - For Hazardous Locations Refer to Class Description for program details Class I, Div 1, Groups C and D; Class II, Div 1 Groups F and G: Series LM300 oil level maintainers, Models LM301EX through LM305EX. Switch contacts rated 11 amps and 1/3 hp, 125, 250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated. Ambient Temperature less than 40C. af Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3218-06.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:45:54] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS 3211-86 INDUSTRIAL CONTROL EQUIPMENT-Motor ControllersMiscellaneous-Certified to U.S. Standards FILE 078646_0_000 Refer to Class Description for program details Series LM300 oil level maintainers, Models LM301 through LM305 and LM311 through LM315. Switch contacts rated 11 amps and 1/3 hp, 125, 250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated. Ambient Temperature less than 40C. af Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3211-86.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:43:46] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS 3211-06 INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers Miscellaneous FILE 078646_0_000 Refer to Class Description for program details Series LM300 oil level maintainers, Models LM301 through LM305 and LM311 through LM315. Switch contacts rated 11 amps and 1/3 hp, 125, 250 or 277 VAC; 1/2 amp, 125 VDC; or 1/4 amp, 250 VDC. Enclosure Type 4 rated. Ambient Temperature less than 40C. af Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/078646_0_000-3211-06.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:41:13] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS FILE 069293_0_000 3211-07 INDUSTRIAL CONTROL EQUIPMENT-Miscellaneous Apparatus Refer to Class Description for program details Custom designed engine-generator control panels for surface mounting, wall mounting, or floor mounting each rated 8A, 24V dc max; 5A, 600V ac max as follows: Models MGCM-86-12 (or -24), MGC-862-12 (or -24), MGC-861-12 (or -24); Models MGCM-87-12 (or -24), MGC-872-12 (or -24), MGC-871-12 (or -24); Models MGC-901-12, MGC-901-24, MGC-901-2-12, MGC-901-2-24, MGC-902-12, MGC-902-24, MGC-902-2-12, MGC-2-24, MGC-903-12, MGC-903-24, MGC-903-2-12 and MGC-902-2-24. Notes: 1. An additional suffix (-1) may be used to designate a single phase power supply. 2. An additional suffix "DDA" may be added for sales purposes. Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/069293_0_000-3211-07.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:39:27] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS 2258-83 PROCESS CONTROL EQUIPMENTIntrinsically Safe and Non-IncendiveSystems-For Hazardous LocationsCertified to U.S. Standards FILE 064764_0_000 Refer to Class Description for program details Note: Panel mounted controller and rail mounted terminal block assembly are for installation in a suitable enclosure. S1501 Monitor/Control System, consisting of the following equipment, interconnected per installation drawing 50-08-0017: 1. Model S1501PS-120 Power Supply (explosion-proof), input rated 120V ac, 7.5VA 12/24V dc, 3.5W.Contacts rated 5A, 1/16HP 125V ac, 250V ac 5A, 30V dc 30W max; provides intrinsically safe circuits for Model S1501H Controller. 2. Model S1501H Controller, intrinsically safe and provides I.S. circuits for up to two Model S1500TB32 Sensor Input Switch Terminal Block Assemblies. 3. Up to two Model S1500TB32 Terminal Block Assemblies, intrinsically safe and provides I.S. circuits for voltage-free contacts. Note: Panel Mounted Controller and Rail Mounted Terminal Block Assembly are for installation in a suitable enclosure. \cc Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-83.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:36:51] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA Master Contract: 151230 Class I, Div.2, Groups B, C, D: Air/Fuel Ration (AFR) Controller Series. For Control Compliance or FW Murphy, 160W max. Rated 9 to 32V dc (AFR-ND-R Series and AFR-ND-L Series) And 11 to 30V dc (AFR-WD-R Series and AFR-WD-L Series) Private Label for Miratech Corporation: MEC Series Controllers, 160W max. Rated 9 to 32V dc (MEC-ND-R Series and MEC-ND-L Series) And 11 to 30V dc (MEC-WD-R Series and MEC-WD-L Series) Class I, Division. 2, Groups C and D: Mark III Selectronic Tattletale control system rated 90 to 250V, CD ignition (Mark III - N version) or 12 to 24V dc (Mark III - 12/24 version) and non-incendive field wiring connections as per Dwg HA14227 and HA14228. DIGITAL TACHOMETER SHD30, SHD45 or SHD30-45, CD ignition input 90 to 350V dc, magnetic pick-up 5-120V rms, nonincendive field wiring connections as per Dwg 20-08-0258. TTDJ Series Digital Fault Annunciator rated 10 to 32V dc (DC Models) or 90 to 350V dc (Capacity Discharge Models) Millenium Controller, rated 10 to 32V dc, 3A max. Note: Panel mount equipment. Final installation to be approved by local authorities having jurisdiction. Class I, Division 2, Groups B, C, D, T4: TTD Series Selectronic, Fault Annunciator (TTD-H, Display Head and PSU-2, Power and Control Inputs/Outputs), rated 10 to 32Vdc., 5W max.,or Ignition Input 90 to 250Vdc. Max. ambient 85 deg.C. Instal per drawing 50-08-0718. CLASS 2258-82 PROCESS CONTROL EQUIPMENTFor Hazardous Locations - Certified to US Standards FILE 064764_0_000 Refer to Class Description for program details Note: Equipment is panel mount. Final installation to be approved by Local Authorities having jurisdiction. TDXM-DC, TDXM-DC-W/SP3LATCH and TDXM-DC-W Temperature Scanners, rated 10 to 32V dc, 500mW. Note: Certified as component only and Panel mount. Final installation to be approved by local authorities having jurisdiction. 52-30-XXXX Control Panel Series. Centurion Controller C3 series rated 10 to 32Vdc consisting of C4-1 or CPC4-1 I/O Module, C3-2, C268, MX4 or MX5 , I/O Expansion Module and C3-3 Display Module. Depending upon the version of the software in the Display Module, the Display Module can form the following models: WPC3-3, ESM-D, and MPI-D, C4-3, C3-3S and C4-3S. Models C3-3S and C4-3S are Spanish versions. Max ambient 85°C. http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-82.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:34:47] WellPro Controller series rated 10 to 32Vdc, consisting of WPC3-1 I/O Module and WPC3-3 Display Module. Max ambient 85°C. Notes: 1) This device is OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority Having Jurisdiction at the time of installation. 2) Wiring to or from this device, which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2 Hazardous Locations, as appropriate for the installation. 3) Panel mount equipment. Final installation to be approved by local authorities having jurisdiction. • Models M2-G-XX series (Gateway), rated 10-30Vdc, 1.1W max.; M2-DI (Discrete Remote), powered by one 3.6V “AA” Lithium Battery, 120mW maximum, and M2-TC (Thermal Remote), powered by two 3.6V “AA” Lithium Batteries, 120mW maximum; +85ºC maximum ambient temperature. Model code: M2-G-XX XX = Firmware revision (any alpha/numeric character - not critical to this certification) Notes: These devices are OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority having jurisdiction at the time of installation. Wiring to or from this device (which includes the installation of the antenna), which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2 Hazardous Locations and environmental certifications on the enclosure, as appropriate for the installation. Batteries must be replaced by a qualified technician with either Tadiran TL-5903-S or Lisun ER14505. /dg Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-82.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:34:47] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA Class I, Group D: "Selectronic Tattletale" monitor/control system, consisting of the following equipment, interconnected per Installation Instructions HC9450-A and HC9450-AA: Explosion-proof power supply: Model LCDT-PS-CD(R)-P, or LCDT-PS-CD(R)-N, input: 250V ac max (ignition powered); contacts: 250V ac, 4A; 30V dc, 3A (resistive) or LCDT-PS-120/24/24 input: 120V ac, 6VA; 24V dc, 6VA; 12V dc, 6VA; contacts: 120V ac 30V dc, 4A (resistive). Power supplies provide intrinsically safe power/control circuits to annunciator. Annunciator: Model LCDT-NO or LCDT-NC, intrinsically safe. Terminal Block: Model LCDT-SOTB-NO with Model LCDT-50CA-36 cable assembly or Model LCDT-50TBNC. 1. The annunciators and cable and terminal block assemblies are Certified only for use where the suitability of the installation is to be determined by the local inspection authorities having jurisdiction. 2. Except as connected through Model LCDT-1SB barrier, sensors consist of passive contacts. 3. The power supplies and barrier must be connected to system ground by means of the terminals provided. Model S1500TB32 terminal block assembly, intrinsically safe and provides I.S. circuits for voltage-free contacts. Note: Panel mounted controller and rail mounted terminal block assembly are for installation in a suitable enclosure. S1501 Monitor/Control System, consisting of the following equipment, interconnected per installation drawing 50-08-0017: 1. Model S1501PS-120 Power Supply (explosion-proof), input rated 120V ac, 7.5VA 12/24V dc, 3.5W.Contacts rated 5A, 1/16HP 125V ac, 250V ac 5A, 30V dc 30W max; provides intrinsically safe circuits for Model S1501H Controller. 2. Model S1501H Controller, intrinsically safe and provides I.S. circuits for up to two Model S1500TB32 Sensor Input Switch Terminal Block Assemblies. 3. Up to two Model S1500TB32 Terminal Block Assemblies, intrinsically safe and provides I.S. circuits for voltage-free contacts. Note: Panel Mounted Controller and Rail Mounted Terminal Block Assembly are for installation in a suitable enclosure. CLASS FILE 064764_0_000 2258-03 PROCESS CONTROL EQUIPMENT Intrinsically Safe and Non-Incendive Systems - For Hazardous Locations Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-03.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:31:37] /cc Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-03.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:31:37] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA Master Contract: 151230 Class I, Div.2, Groups B, C, D: Air/Fuel Ration (AFR) Controller Series. For Control Compliance or FW Murphy, 160W max. Rated 9 to 32V dc (AFR-ND-R Series and AFR-ND-L Series) And 11 to 30V dc (AFR-WD-R Series and AFR-WD-L Series) Private Label for Miratech Corporation: MEC Series Controllers, 160W max. Rated 9 to 32V dc (MEC-ND-R Series and MEC-ND-L Series) And 11 to 30V dc (MEC-WD-R Series and MEC-WD-L Series) CLASS 2258-02 PROCESS CONTROL EQUIPMENTFor Hazardous Locations FILE 064764_0_000 Refer to Class Description for program details Class I, Division 2, Group D: Notes: 1. The equipment to be installed in suitable enclosures accepted by local authorities. 2. The equipment can be listed also as FAIRBANKS MORSE as manufacturer. TDX6 Temperature Scanner powered by Certified CD ignition FAIRBANKS 9000, BENDIX S1800 and ALTRONIC I and III or 120V ac. MDTM89 Dual Temperature Switch gauge powered by Certified CD ignition FAIRBANKS 9000, BENDIX S1800 and ALTRONIC I and III or 12-24V dc. Class I, Division 2, Groups C and D: MARK IV SELECTRONIC TATTLETALE control system rated 80 to 250V, CD ignition (MARK IV-N version) or 12 to 24V dc/4.7W (MARK IV-12/24 version) and non-incendive field wiring connections as per Dwg. HC 13439 and HC 13443. Mark III Selectronic tattletale control system rated 90 to 250V, CD ignition Mark III - N version) or 12 to 24V dc (Mark III - 12/24 version) and non-incendive field wiring connections as per Dwg HA14227 and HA14228. DIGITAL TACHOMETER SHD30, SHD45 or SHD30-45, CD ignition input 90 to 350V dc, magnetic pick-up 5-120V rms, nonincendive field wiring connections as per Dwg 20-08-0258. TTDJ Series Digital Fault Annunciator rated 10 to 32V dc (DC Models) or 90 to 350V dc (Capacity Discharge Models) Millenium Controller, rated 10 to 32V dc, 3A max. Note: Panel mount equipment. Final installation to be approved by local authorities having jurisdiction. Class I, Division 2, Groups B, C, D, T4: TTD Series Selectronic, Fault Annunciator (TTD-H, Display Head and PSU-2, Power Sontrol Inputs/Outputs), rated 10 to 32Vdc., 5W max.,or Ignition Input 90 to 250Vdc. Max. ambient 85 deg.C. Install per drawing 500-08-0718 http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:28:42] Note: Equipment is panel mount. Final installation to be approved by Local Authorities having jurisdiction. TDXM-DC, TDXM-DC-W/SP3LATCH and TDXM-DC-W Temperature Scanners, rated 10 to 32V dc, 500mW. Note: Certified as component only and Panel mount. Final installation to be approved by local authorities having jurisdiction. 52-30-XXXX Control Panel Series. Centurion Controller C3 series rated 10 to 32Vdc consisting of C4-1 or CPC4-1 I/O Module, C3-2, C268, MX4 or MX5 , I/O Expansion Module and C3-3 Display Module. Depending upon the version of the software in the Display Module, the Display Module can form the following models: WPC3-3, ESM-D, MPI-D, C4-3, C3-3S and C4-3S. Models C3-3S and C4-3S are Spanish versions. Max ambient 85°C. WellPro Controller series rated 10 to 32Vdc, consisting of WPC3-1 I/O Module and WPC3-3 Display Module. Max ambient 85°C. Notes: 1) This device is OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority Having Jurisdiction at the time of installation. 2) Wiring to or from this device, which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2 Hazardous Locations, as appropriate for the installation. 3) Panel mount equipment. Final installation to be approved by local authorities having jurisdiction. • Models M2-G-XX series (Gateway), rated 10-30Vdc, 1.1W max.; M2-DI (Discrete Remote), powered by one 3.6V “AA” Lithium Battery, 120mW maximum, and M2-TC (Thermal Remote), powered by two 3.6V “AA” Lithium Batteries, 120mW maximum; +85ºC maximum ambient temperature. Model code: M2-G-XX XX = Firmware revision (any alpha/numeric character - not critical to this certification) Notes: These devices are OPEN type equipment that must be used within a suitable end-use system enclosure, the interior of which is accessible only through the use of a tool. The suitability of the enclosure is subject to investigation by the local Authority having jurisdiction at the time of installation. Wiring to or from this device (which includes the installation of the antenna), which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2 Hazardous Locations and environmental certifications on the enclosure, as appropriate for the installation. Batteries must be replaced by a qualified technician with either Tadiran TL-5903-S or Lisun ER14505. /dg Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/064764_0_000-2258-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:28:42] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA Class I, Groups C and D: Junction boxes, Models 65-05-148; with solid cover, with/without hinges; Models 8101-EX and 8102-EX with glass lens in cover. Copyright © 2011 CSA International. All rights reserved. CLASS 4418-02 OUTLET BOXES AND FITTINGSBoxes - For Hazardous Locations FILE 046564_0_000 Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/046564_0_000-4418-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:26:40] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA Class I, Groups C and D: Vibration- shock detector switch Model VS2EX, 480V ac max. 5A, or VS2EXR rated 24V dc or 120V ac nominal. Ambient temperature rating: -40ºC to +60ºC Note: This equipment can be listed under IMI SENSORS as manufacturer name and under Model 685A08. Class I, Div 2, Groups B, C, D; T4: EVS Series Vibration Switch, rated input 8 to 32V dc/100mA max. Solid State alarm output rated 40Vdc/50mA. Max ambient 85DegC. /dg Copyright © 2011 CSA International. All rights reserved. CLASS FILE 046306_0_000 3218-86 INDUSTRIAL CONTROL EQUIPMENT-Miscellaneous ApparatusFor Hazardous Locations-Certified to U.S. Standards Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/046306_0_000-3218-86.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:24:15] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS FILE 046306_0_000 3218-06 INDUSTRIAL CONTROL EQUIPMENT-Miscellaneous Apparatus - For Hazardous Locations Refer to Class Description for program details Vibration- shock detector switch Model VS2EX, 480V ac max. 5A, or VS2EXR rated 24V dc or 120V ac nominal. Ambient temperature rating: -40ºC to +60ºC Note: This equipment can be listed under IMI SENSORS as manufacturer name and under Model 685A08. Class I, Div 2, Groups B, C, D; T4: EVS Series Vibration Switch, rated input 8 to 32V dc/100mA max. Solid State alarm output rated 40Vdc/50mA. Max ambient 85DegC. /dg Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/046306_0_000-3218-06.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:23:12] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA MISCELLANEOUS CONTROLS: Pressure actuated controls, Series OPL, rated 30V ac, 2A (ind), Series OPLC, rated 125V ac, 125VA pilot duty; Series 45-PE, rated 250V ac, 1A (ind); 250V ac, 4A; 250V ac, 2A. Level indicating controls, Series OPL-H and OPL-HA, rated same as OPL Series, Series OPL-HC and OPLHACS, rated same as OPLC Series; Series 45-LE rated same as 45-PE Series. Temperature actuated controls, Series SPL, rated same as OPL Series, Series SPLC, rated same as OPLC Series; Series 45-TE rated same as 45-PE Series. Pressure actuated controls, Model OPL-BP, level actuated controls, Model OPL-HA-BP, and temperature actuated controls, Model SPL-BP, rated 120V ac, 10A, 125VA pilot duty. Note: The controls enclosures are Certified as Enclosure 3. Pressure actuated controls, Series OPL-F, rated 30V ac, 2A (ind), Series OPL-FC, rated 125V ac, 125VA pilot duty; Series 45-PEF, rated 250V ac, 1A; (ind); 250V ac, 4A; 250V ac, 2A. Level indicating controls, Series OPL-HF and OPL-HAF, rated same as OPL-F Series, Series OPL-HFC and OPL-HAFCS rated same as OPL-FC Series; Series 45-LEF, rated same as 45-PEF Series. Temperature actuated controls, Series SPL-F, rated same as OPL-F Series, Series SPL-FC, rated same as OPLFC Series; Series 45-TEF rated same as 45-PEF Series. Level indicating control, Model OPL-HA-FP, rated 125V ac, 125VA pilot duty. Note: Model number for above controls includes the series number, followed by the gauge range. Pressure actuated controls, Series 45APE, 45APEF, rated 250V ac, 2A; 6000 cycles. Level indicating controls, Series 45ALE, 45ALEF, rated 250V ac, 2A; 6000 cycles. Temperature actuated controls, Series 45ATE, 45ATEF, rated 250V ac, 2A; 6000 cycles. Notes: 1. Suffix numbers may be used to indicate enclosure mounting, ratings, gauge range and securing element variations. 2. The controls are Certified for component use only. /mr Copyright © 2011 CSA International. All rights reserved. CLASS FILE 046305_0_000 4813-02 TEMPERATURE-INDICATING AND REGULATING EQUIPMENT-Other Than Appliance Type Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/046305_0_000-4813-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:57:01] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS 3218-85 INDUSTRIAL CONTROL EQUIPMENT-Motor ControllersMiscellaneous-For Hazardous Locations-Certified to U.S. Standards FILE 046304_0_000 Refer to Class Description for program details Class I; Division 1; Groups B, C and D; MLS Series Liquid Level Switch models: MLS015 and MLS020. Electrical ratings are 30VDC/VAC at 75 mA. Maximum working pressure is 13.8 MPa (2000 psig). Process temperature range is -29°C to 149°C (-20°F to 300°F). Ambient temperature range is -29°C to 85°C (-20°F to 185°F). Temperature code T5. Enclosure rated IP66. Single Seal. Class I, Groups C and D: Float switches, Models L-1100, L-1200, L-1111, and LS200, 480V ac max, 5A, with suffixes, 125/250Vac, 10A. Max. working pressure 2000 psi. Float Switch Model Codes: L-1100, L-1111, L-1200, or LS200 may be followed by -a-b-c-d-e# a=Blank or SS (Blank=Standard body; SS=Stainless Steel Body) b=Blank or SF (Blank=Standard Float*; SF=Stainless Steel Float**) c=Blank or D (Blank=SPDT switch; D=DPDT switch) d=Blank or 400 (Blank=Standard Temp. Range; 400=400°F*** (203°C) Service) e#=Blank or K (Blank=Standard Viton Seals; K=KALREZ Seals) *=Stainless Steel float is standard for LS200 and does not show the SF option. **= Stainless Steel float is not available on the L1111. ***=Not available with DPDT switch. # = Not safety critical for this certification. af Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/046304_0_000-3218-85.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:54:30] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS 3218-05 INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers Miscellaneous - For Hazardous Locations FILE 046304_0_000 Refer to Class Description for program details Class I; Division 1; Groups B, C and D; MLS Series Liquid Level Switch models: MLS015 and MLS020. Electrical ratings are 30VDC/VAC at 75 mA. Maximum working pressure is 13.8 MPa (2000 psig). Process temperature range is -29°C to 149°C (-20°F to 300°F). Ambient temperature range is -29°C to 85°C (-20°F to 185°F). Temperature code T5. Enclosure rated IP66. Single Seal. Class I, Groups C and D: Float switch, stationary, Model EL-150-EX, 10A, 125/250V ac. Float switches, Models L-1100, L-1200, L-1111, and LS200, 480V ac max, 5A, with suffixes, 125/250Vac, 10A. Max working pressure 2000 psi. Float Switch Model Codes: L-1100, L-1111, L-1200, or LS200 may be followed by -a-b-c-d-e# a=Blank or SS (Blank=Standard body; SS=Stainless Steel Body) b=Blank or SF (Blank=Standard Float*; SF=Stainless Steel Float**) c=Blank or D (Blank=SPDT switch; D=DPDT switch) d=Blank or 400 (Blank=Standard Temp. Range; 400=400°F*** (203°C) Service) e#=Blank or K (Blank=Standard Viton Seals; K=KALREZ Seals) *=Stainless Steel float is standard for LS200 and does not show the SF option. **= Stainless Steel float is not available on the L1111. ***=Not available with DPDT switch. # = Not safety critical for this certification. Class I, Groups C and D; Class II, Groups F and G: Float Switches, Model L971, L971-A, thru -G, L972, L972-A thru -G, rated 4A, 250V ac. af Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/046304_0_000-3218-05.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:51:55] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS FILE 028623_0_000 3211-07 INDUSTRIAL CONTROL EQUIPMENT-Miscellaneous Apparatus Refer to Class Description for program details Motor Control Assemblies, 480V ac, max 10A, Cat Nos TR7207, TR7208, TR5171, TR7159, TR9193, TR9194, TR9195, TR-1760, TR-1761, TR-1762, in general purpose or weatherproof (Encl. 3) enclosures. "Switchgage" indicating controls: Series A25EO- or A25PE; pressure type, 400 psi and less; Series A25ESR-, or A25TE temperature type; contact rating 4A, 120V ac. Notes: 1. Cat Nos may have additional suffix letter to denote variations in construction. 2. "Switchgage" indicating controls may have added suffixes, ES or OS. Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/028623_0_000-3211-07.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:47:06] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS I, GROUPS C AND D: Time controlled automatic switches, Models 5-TEX, 15-TEX, (minutes) and Models 12-TEX, 24-TEX (hours) rated 5A, 480V ac, 10A, 250V ac, and 15A, 48V dc. Copyright © 2011 CSA International. All rights reserved. CLASS 4878-01 TIME INDICATING AND RECORDING APPLIANCES-For Hazardous Locations FILE 027183_0_000 Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/027183_0_000-4878-01.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:44:29] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA Class I, Groups C and D Fuel gas shutoff valves, 5 A max., intermittent duty, Models M-50-81 and M-50-81CD engine ignition powered, and Model M-50-81B. 12 or 24 V ac or dc, switch contacts rated 5 A, 480 Vac max, maximum working pressure 100 psi (689 kPa). Copyright © 2011 CSA International. All rights reserved. CLASS 3228-01 VALVES-For Hazardous Locations FILE 021357_0_000 Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/021357_0_000-3228-01.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:38:38] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS 3218-85 INDUSTRIAL CONTROL EQUIPMENT-Motor ControllersMiscellaneous-For Hazardous Locations-Certified to U.S. Standards FILE 018709_0_000 Refer to Class Description for program details Class I, Division 1, Groups C and D: “Switchgage” Pressure Indicating Controls: Series 45APE-EX having contacts rated 250V ac, 2 Amp (Ind), Series OPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45PE-EX having contacts rated 250 Vac, 3 Amp (IND, 6000 cycles). Maximum working Pressure 5,000 psi (34.5 MPa). “Switchgage” Level Indicating Controls: Series 45ALE-EX having contacts rated 250V ac, 2 Amp (Ind), Series OPLHACS-EX and OPLHC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles). Maximum working Pressure 5,000 psi (34.5 MPa). “Switchgage” Temperature Indicating Controls: Series 45ATE-EX having contacts rated 250V ac, 2 Amp (Ind), Series SPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45TE-EX having contacts rated 250 Vac, 3 Amp (IND, 6000 cycles) . /ahf Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/018709_0_000-3218-85.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:37:14] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA Class I, Division I, Groups C and D: “Switchgage” Pressure Indicating Controls: Series 45APE-EX having contacts rated 250V ac, 2 Amp (Ind), Series OPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45PE-EX having contacts rated 250 Vac, 3 Amp (IND, 6000 cycles). Maximum working Pressure 5,000 psi (34.5 MPa). “Switchgage” Level Indicating Controls: Series 45ALE-EX having contacts rated 250V ac, 2 Amp (Ind), Series OPLHACS-EX and OPLHC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles). Maximum working Pressure 5,000 psi (34.5 MPa). “Switchgage” Temperature Indicating Controls: Series 45ATE-EX having contacts rated 250V ac, 2 Amp (Ind), Series SPLC-EX having contacts rated 125 Vac, 1 Amp pilot duty (6000 cycles) and Series 45TE-EX having contacts rated 250 Vac, 3 Amp (IND, 6000 cycles). Pressure switch, stationary, Model DF-755-EX 20 in or less water column, 480V ac and less, 5A. "Swichgage" Indicating Controls: Pressure switch, Series PT-167-EX, rated 250V ac, 1A (Ind). "Swichgage" Indicating Controls: Pressure switch, Series 25-EOEX, pressure range 0 to 15 and up to 300 psi. Rated 4A, 120V, ac. Temperature Switch, series 25-ESREX, temperature range -20 to 450F, rated 4A 120V ac. "Swichgage" Indicating Controls: Temperature gauge/switch Model SDB-500-EX, temperature range 0 to 500F, rated 2A 120V ac. /ahf Copyright © 2011 CSA International. All rights reserved. CLASS 3218-05 INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers Miscellaneous - For Hazardous Locations FILE 018709_0_000 Refer to Class Description for program details http://directories.csa-international.org/xml_transform.asp?xml=certxml/018709_0_000-3218-05.xml&xsl=xsl/certrec.xsl[06-Jan-11 13:26:53] Certification Record CUSTOMER FW Murphy P.O. Box 470248, Tulsa OK 74147 USA CLASS 3218-02 INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers Auxiliary Devices-For Hazardous Locations FILE 018709_0_000 Refer to Class Description for program details Class I, Groups C and D: Transformer relays, Models TR-1760-EX, TR-1761-EX, TR-1762-EX, TR-5171-EX, TR-7207-EX, TR-7208EX, TR-7159-EX, TR-9193-EX, TR-9194-EX, and TR-9195-EX input 120/240/480V ac, 60Hz, 25VA, holding contacts 480V ac max, 10A; auxiliary contacts, 480V ac, 690 VA Pilot Duty. Copyright © 2011 CSA International. All rights reserved. http://directories.csa-international.org/xml_transform.asp?xml=certxml/018709_0_000-3218-02.xml&xsl=xsl/certrec.xsl[06-Jan-11 14:19:00] ANNEX B (November 10, 2003) Targeted End Products (Low Voltage Distribution and Control Equipment): Category Name Automatic Transfer Switches for Use in Emergency Systems - United States Automatic Transfer Switches for Use in Emergency Systems – Canada Automatic Transfer Switches for Use in Optional Standby Systems - United States Automatic Transfer Switches for Use in Optional Standby Systems – Canada Combination Motor Controllers - United States Combination Motor Controllers – Canada Industrial Control Panels - United States Industrial Control Panels – Canada Motor Control Centers - United States Motor Control Centers – Canada Non-automatic Transfer Switches - United States Non-automatic Transfer Switches – Canada Panelboards - United States Panelboards – Canada Power Conversion Equipment - United States Power Conversion Equipment – Canada Power Outlets and Power Outlet Fittings - United States Power Outlets and Power Outlet Fittings – Canada Switchboards, Dead Front - United States Switchboards, Dead Front – Canada Switchgear Assemblies, Metal Enclosed, Low-voltage Power Circuit Breaker Type - United States Switchgear Assemblies, Metal Enclosed, Low-voltage Power Circuit Breaker Type – Canada CCN WPWR WPWR7 WPXT WPXT7 NKJH NKJH7 NITW NITW7 NJAV NJAV7 WPYV WPYV7 QEUY QEUY7 NMMS NMMS7 QPYV QPYV7 WEVZ WEVZ7 WUTZ WUTZ7 CSA Class 3211-81 3211-01 3211-81 3211-01 3211-84 3211-04 3211-89 3211-87 3211-09 3211-07 3211-84 3211-04 4652-84 4652-04 4621-81 4621-01 3211-86 3211-06 6233-83 6233-03 4621-81 4621-01 4641-81 4641-01 ANNEX A (November Targeted Component Categories: Category Name Auxiliary Devices - United States Auxiliary Devices – Canada Auxiliary Devices - Component - United States Auxiliary Devices - Component – Canada Cartridge Fuses, Nonrenewable - United States Cartridge Fuses, Nonrenewable – Canada Cartridge Fuses, Renewable - United States Cartridge Fuses, Renewable – Canada Circuit Breaker Accessories – Co mponent - United States Circuit Breaker Accessories – Component - Canada Circuit Breaker and Ground-fault Circuit Interrupters - United States Circuit Breaker and Ground-fault Circuit Interrupters - Canada Circuit Breaker and Ground-fault Circuit Interrupters - Component - United States Circuit Breaker and Ground-fault Circuit Interrupters - Component - Canada Circuit Breaker Current Limiters –United States Circuit Breaker Current Limiters - Canada Circuit Breakers With Equipment Ground Fault - United States Circuit Breakers With Equipment Ground Fault - Canada Circuit Breakers, Adjustable Instantaneous Trip Type - Component -United States Circuit Breakers, Adjustable Instantaneous Trip Type - Component - Canada Circuit Breakers, Molded-Case And Circuit Breakers - United States Circuit Breakers, Molded-Case And Circuit Breakers - Canada Circuit Breakers, Molded-case, Classified for Use in Specified Equipment - United States Circuit Breakers, Molded-case, Classified for Use in Specified Equipment - Canada Combination Motor Controllers - Component - United States Combination Motor Controllers - Component - Canada Fuse Accessories - United States CCN NKCR NKCR7 NKCR2 NKCR8 JDDZ JDDZ7 JDRX JDRX7 DIHS2 DIHS8 DKUY DKUY7 DKUY8 DKUY2 DIRW DIRW7 DIYA DIYA7 DKPU2 DKPU8 DIVQ DIVQ7 DIXF DIXF7 NKJH2 NKJH8 JDVS CSA Class 3211-83 3211-03 **3211-87 **3211-07 1421-81 1421-01 1421-82 1421-02 1437-81 1437-01 1451-81 1451-01 **1451-81 **1451-01 1432-81 1432-01 1451-81 1451-01 **4652-84 **4652-04 1432-81 1432-01 **1432-81 **1432-01 3211-84 3211-04 **6225-81 or 1422-81 **6225-01 or 1422-01 **6225-81 or 1422-81 **6225-01 or 1422-01 **1422-81 **1422-01 6225-81 6225-01 **6225-81 **6225-01 1422-81 1422-01 1422-90 1422-30 **1422-90 **1422-30 4812-82 4812-02 10, 2003) Fuse Accessories – Canada JDVS7 Fuse Accessories - Component - United States JDVS2 Fuse Accessories - Component – Canada JDVS8 Fuse, Special Purpose - United States Fuse, Special Purpose – Canada Fuseholders, Cartridge Fuse - United States Fuseholders, Cartridge Fuse – Canada Fuseholders, Cartridge Fuse - Component - United States Fuseholders, Cartridge Fuse - Component - Canada Fuses, Mis cellaneous, Miniature And Micro - United States Fuses, Miscellaneous, Miniature And Micro - Canada Fuses, Miscellaneous, Miniature, And Micro - Component - United States Fuses, Miscellaneous, Miniature, And Micro - Component - Canada Fuses, Special Purpose - Component - United States Fuses, Special Purpose - Component - Canada Ground-Fault Sensing And Relaying Equipment - United States Ground-Fault Sensing And Relaying Equipment - Canada JFHR JFHR7 IZLT IZLT7 IZLT2 IZLT8 JDYX JDYX7 JDYX2 JDYX8 JFHR2 JFHR8 KDAX KDAX7 Ground-Fault Sensing And Relaying Equipment - Component - United States Ground-Fault Sensing And Relaying Equipment - Component -Canada Industrial Control Panels - Component - United States Industrial Control Panels - Component - Canada Industrial Control, Miscellaneous Apparatus - United States Industrial Control, Miscellaneous Apparatus - Canada Industrial Control, Miscellaneous Apparatus - Component - United States Industrial Control, Miscellaneous Apparatus - Component - Canada Lampholders, Miscellaneous - United States Lampholders, Miscellaneous – Canada Lampholders, Miscellaneous - Component - United States KDAX2 KDAX8 NITW2 NITW8 NMTR NMTR7 NMTR2 NMTR8 OOIX OOIX7 OOIX2 Lampholders, Miscellaneous - Component - Canada OOIX8 Meter Socket Accessories - United States Meter Socket Accessories – Canada Meter Socket Accessories - Component - United States Meter Socket Accessories - Component - Canada Meter Socket Bases - United States Meter Socket Bases – Canada Meter Socket Bases and Associated - United States Meter Socket Bases and Associated - Canada Motor Controllers, Float-And Pressure - United States Motor Controllers, Float-And Pressure - Canada Motor Controllers, Float-And-Pressure - United States PKAX PKAX7 PKAX2 PKAX8 PJWT PJWT7 POCQ2 POCQ8 NKPZ NKPZ7 NKPZ2 Motor Controllers, Float-And-Pressure - Canada NKPZ8 Motor Controllers, Magnetic - United States Motor Controllers, Magnetic – Canada Motor Controllers, Magnetic - Component - United States Motor Controllers, Magnetic - Component - Canada Motor Controllers, Manual - United States Motor Controllers, Manual – Canada Motor Controllers, Manual - Component - United States Motor Controllers, Manual - Component - Canada Motor Controllers, Miscellaneous - United States Motor Controllers, Miscellaneous - Canada Motor Controllers, Miscellaneous - Component - United States Motor Controllers, Miscellaneous - Component - Canada Panelboard And Switchboard Accessories - United States Panelboard And Switchboard Accessories - Canada Plug Fuse, Fuseholders - United States Plug Fuse, Fuseholders – Canada Plug Fuse, Fuseholders - Component - United States Plug Fuse, Fuseholders - Component - Canada Plug Fuses - United States Plug Fuses – Canada Power Conversion Equipment - United States Power Conversion Equipment – Canada Power Conversion Equipment - Component - United States Power Conversion Equipment - Component - Canada Programmable Controllers - United States Programmable Controllers – Canada Programmable Controllers - Component - United States NLDX NLDX7 NLDX2 NLDX8 NLRV NLRV7 NLRV2 NLRV8 NMFT NMFT7 NMFT2 NMFT8 QEUY2 QEUY8 JAMZ JAMZ7 JAMZ2 JAMZ8 JEFV JEFV7 NMMS NMMS7 NMMS2 NMMS8 NRAQ NRAQ7 NRAQ2 **4812-82 **4812-02 3211-89 3211-09 3211-87 3211-07 **3211-87 **3211-07 6231-87 6231-07 ** 6231-81 6231-89 ** 6231-01 6231-09 4632-81 4632-01 **4632-81 **4632-01 4632-81 4632-01 4632-81 4632-01 3211-86 3211-06 ** 3231-82 3211-87 ** 3231-02 3211-07 3211-84 3211-04 **3231-81 **3231-01 3211-85 3211-05 **3211-85 **3211-05 3211-86 3211-06 **3211-86 **3211-06 **4621-82 **4621-02 6225-81 6225-01 **6225-82 **6225-02 1423-81 1423-01 3211-86 3211-06 **3211-86 **3211-06 2252-81 2252-01 2252-91 Programmable Controllers - Component – Canada Protective Relays - United States Protective Relays – Canada Protective Relays - Component - United States Protective Relays - Comp onent – Canada Protectors, Supplementary - Component - United States Protectors, Supplementary - Component – Canada Relay Sockets and Assemblies - Component - United States NRAQ8 NRGU NRGU7 NRGU2 NRGU8 QVNU2 QVNU8 SWIV2 Relay Sockets and Assemblies - Component – Canada SWIV8 Switches, Enclosed - United States Switches, Enclosed – Canada Switches, Industrial Control - United States Switches, Industrial Control – Canada Switches, Industrial Control - Component - United States Switches, Industrial Control - Component – Canada Switches, Molded Case - United States Switches, Molded Case – Canada Terminal Blocks - Components - United States Terminal Blocks - Components – Canada WIAX WIAX7 NRNT NRNT7 NRNT2 NRNT8 WJAZ WJAZ7 XCFR2 XCFR8 2252-01 3211-83 3211-03 **3211-83 **3211-03 3215-90 3215-30 ** 3211-87 3211-83 ** 3211-07 3211-03 4651-81 4651-01 4652-84 4652-04 **4652-84 **4652-04 4652-86 4652-06 6228-81 6228-01 Notes: ** - CSA does not have a corresponding category for this UL product category. CSA covers these products under another Class Number as identified adjacent to the double asterisk ”**”.
Copyright © 2024 DOKUMEN.SITE Inc.