2004wiring accessories circuit protection Acknowledged as one of Britain‘s leading manufacturers of wiring accessories and circuit protection equipment. Crabtree‘s diverse product range is renowned for its outstanding quality and excellent value for money. Specified worldwide, Crabtree products are designed to satisfy the needs of specifiers, wholesalers, contractors and end-users in domestic, commercial and industrial markets alike. Crabtree’s reputation for pioneering new concepts in the electrical industry – right from the acclaimed Lincoln Switch in 1919 to the launch of the latest innovation in wiring accessories - Platinum a brand new low profile & flat plate wiring accessories range, maintaining our position at the forefront of manufacturing technology. It is this insight into our customers’ needs, together with the technical expertise to turn innovative ideas into top quality products that has made Crabtree a market leader. Every Crabtree product is rigorously tested before being despatched to the customer. This excellence is reinforced by the company’s registration of compliance with ISO 9001: 2000 which ensures that these procedures are maintained at the highest level. Crabtree’s product ranges are developed with flexibility in mind, and with the evolution of more modular ranges, customers can be confident of obtaining the right product for each application. The same attention to detail can be seen in the company‘s commitment to customer service. With up-to-the minute technology at the heart of its management information systems, the company is able to manufacture and despatch in the shortest possible time, whilst a communications network in its Central Sales Office ensures that customer enquiries are dealt with speedily and effectively. The company’s commitment does not end there. Specifying Crabtree products ensures not only a first class product, but also the benefit of a wide range of support services. For example, comprehensive product and technical literature, a highly qualified sales force and extensive wholesaler training. Crabtree‘s Technical Services Department is able to offer expert advice on technical issues, and the preparation of individual quotes. All Crabtree products comply with the applicable British Standard specification and should be installed by suitably qualified personnel in accordance with the requirements of relevant legislation, regulations (including IEE Wiring Regulations) and the accepted practice in the industry. For ease of product selection, the catalogue is divided into sections. Each has its own introduction and contains relevant product information. C A P I TA L P O W E R & C O N T R O L It is the practice of the Electrium Group of companies to protect new ideas by seeking patent protection, and to protect new designs by seeking registered design protection, and the products listed or described in this publication may in consequence be protected by one or more patents, and/or registered designs and/or applications. A full list of patents, registered designs and applications may be obtained from the Company Secretary of Electrium Limited. 2 C A P I TA L & M I N D E R L I G H T I N G C O N T R O L 12 P L AT I N U M L O W P R O F I L E & F L AT P L AT E 20 C A P I TA L M E TA L P L AT E 30 C A P I TA L D E C O R AT I V E B R A S S 38 ROCKERGRID MODULAR SYSTEM 44 C A P I TA L M E TA L C L A D 52 W E AT H E R S E A L WAT E R & D U S T P R O T E C T E D 56 C A P I TA L I N T E R I O R S & PA N E L M O U N T I N G 62 C A P I TA L I N S TA L L AT I O N B O X E S & S E R V I C E I T E M S 66 D ATA PA K D ATA , V O I C E & PAT C H PA N E L S 70 LSC LUMINAIRE SUPPORT COUPLERS 74 LDB LUMINAIRE DISTRIBUTION BOXES 76 WA RW I C K P V C T R U N K I N G 78 S TA R B R E A K E R D O M E S T I C C I R C U I T P R O T E C T I O N 88 L I F E S TA R R C D 101 T E C H N I C A L D ATA 105 DIMENSIONS 122 NUMERICAL INDEX 133 Positive drive switch action prevents balancing between the ‘on’ and ‘off’ position and gives reliable indication of the contact position. Unique labyrinth switch design minimises visible arc flash and prevents front access to live parts.POWER & CONTROL Wide concave rockers are easy to operate. 2 . The range of socket outlets. fused connection units and switches is complemented by products which cater for specific applications such as cooker control units.American standard socket now available in horizontal format Shutter mechanism is operated by earth pin of plug. New Twin Switched Socket with outboard Rockers C A P I TA L P O W E R & C O N T R O L Capital power and control accessories are fully design co-ordinated to offer 3 . Two earth terminals are fitted as standard to the Single and Twin Socket. consistent styling and inherent safety features across a broad range of applications. fan control switches and shower control switches. shaver units. Shallow back projection for ease of installation in a 25mm deep box. ● ● 4307 13A UNSWITCHED SOCKET OUTLETS BS 1363 1 gang unswitched 1 gang unswitched with two earth terminals 2 gang unswitched 2 gang unswitched with two earth terminals Dimensions Mounting boxes 7255 1 2 1 2 gang gang gang gang BS 1363 10 4827 DP Switched with neon indicator 10 4827/3 Unswitched 10 4828 10 4828/3 Unswitched with neon indicator Dimensions Mounting boxes ● ● ● ● ● C A P I TA L P O W E R ● 4 l PACK QTY DP Switched 4827/3 7255 7255/TE 7257 7257/TE 86mm x 86mm 146mm x 86mm 9047 surface. or SB619 dry lining 9048 surface. . Shallow back projection for ease of installation in a 25mm deep box. Suitable for flexible cord up to 10mm outside diameter. With fuse removed. 3mm contact gap. Can be installed to replace any 2 gang size socket outlet on 25mm deep box. 4406/A03 l PACK QTY 1 gang switched with neon indicator 10mA tripping current 1 4404/A01 1 gang switched with neon indicator 30mA tripping current 1 4404/A03 2 gang switched with neon indicator 10mA tripping current 1 4406/A01 2 gang switched with neon indicator 30mA tripping current 1 4406/A03 Dimensions Mounting boxes 146mm x 86mm 9048 surface. SB665 flush galv. ● Two Earth terminals for use where compliance with section 607 (IEE wiring Regs. SB665 flush galv. Suitable padlock see page 100. SB655 flush galv. 13A SAFETYSOCKET WITH RCD PROTECTION BS 7288 Double pole operation. or SB629 dry lining See page 102 for further information. SB655 flush galv. or SB619 dry lining 9048 surface. Reset button gives a highly visible indication of device status. All available with two earth terminals to enable installation to comply with section 607 (wiring regulations) Add suffix /TE to List No. Fuse ASTA certified and marked to BS1362.). or SB619 dry lining Fitted with knock-out position in bottom edge of plate for use with or without cord outlet.13A SWITCHED SOCKET OUTLETS 4304/3 4306 l BS 1363 1 gang SP with two earth terminals PACK QTY 10 1 gang SP fitted with neon indicator 10 4304/3 1 gang DP with two earth terminals 10 4304/D 1 gang DP fitted with neon indicator 10 4304/3D 2 gang SP fitted with two earth terminals 5 4306 2 gang SP fitted with neon indicator 5 4306/3 2 gang DP fitted with two earth terminals 5 4306/D 2 gang DP fitted with neon indicator 5 4306/3D 2 gang DP outboard rockers twin earth 5 4307 2 gang DP outboard rockers with neon indicator 5 4307/3 Dimensions Mounting boxes 1 2 1 2 gang gang gang gang 4304 86mm x 86mm 146mm x 86mm 9047 surface. SB665 flush galv. high integrity earthing is necessary. carrier may be padlocked for extra on site ‘maintenance’ safety. Fused on the line side with a 13A fuse link. or SB629 dry lining 13A FUSED CONNECTION UNITS 4828 l PACK QTY 10 10 5 5 86mm x 86mm 9047 surface. SB655 flush galv. For spare fuse links see page 6. or SB629 dry lining Large capacity tunnel type terminals for easy wiring. or SB619 dry lining 2382 – 9041 surface. SB655 flush galv.5A. or SB619 dry lining 2A. 7046. SB665 flush galv. SB655 flush galv.5mm2 cable. or SB629 dry lining Push-in termination accepts 2. 7062/E BLANKING PLATES l BS 5733 WHERE APPLICABLE 20 4001 2 gang 20 4002 1 gang architrave 20 4003 2 gang architrave 20 4004 Dimensions 4001 4002 PACK QTY 1 gang 1 gang 86mm x 86mm. or SB619 dry lining 7048–9041 surface. 5A. 15A. SB655 flush galv. SB615 flush galv. or SB619 dry lining 2 gang 9048 surface. 7047–9047 surface. SB615 flush galv. or SB619 dry lining * Export only 15A 125V AMERICAN STANDARD SOCKET OUTLETS l NEMA CONFIGURATION 5-15 10 7061 2 gang horizontal 5 7062 2 gang vertical 5 7062/E Dimensions Mounting boxes 7062 PACK QTY 1 gang 1 gang 86mm x 86mm 2 gang 86mm x 146mm 1 gang 9047 surface.5-16A 2 pin unswitched unshuttered 10 7044* 2A unswitched shuttered 10 7046 2A unswitched unshuttered 10 7046/E* 5A unswitched shuttered 10 7047 15A unswitched shuttered 10 7048 Dimensions Mounting boxes 7044 l PACK QTY 7046/E 86mm x 86mm 7044. 2 gang 146mm x 86mm 1 gang architrave 33mm x 86mm 2 gang architrave 33mm x 146mm C A P I TA L P O W E R 7061 5 . 16A SOCKET OUTLETS BS 546 WHERE APPLICABLE l PACK QTY 2. 15A SWITCHED SOCKET OUTLETS BS 546 5A shuttered SP 15A shuttered SP Dimensions Mounting boxes 2330 2382 10 2330 10 2382 86mm x 86mm 2330 – 9047 surface. Screw-in termination accepts 4mm2 cable. see below. Cover in rubber material.6925 which is type tested to BS 4265:1977 rated at 3.3A. 15A PLUGS BS 546 l PACK QTY 2A 10 7011 5A 10 7111 15A 10 7211 C A P I TA L P O W E R Moulded from white thermoset plastic. List Nos. 13A FUSED SAFETY PLUGS BS 1363 ASTA MARKED l PACK QTY Fused at 13A 10 7221 Fused at 3A 10 7221/3 Live and neutral pins have moulded nylon sleeves for safety. except List No. 5A. Round pin plugs are not fused. ASTA approved by reference number 4.15 A 250V. see below.6920/3 and 6920/13. ASTA approved by reference number 20. Fitted with ASTA certified fuse-link marked to BS 1362. Live and neutral pins have moulded nylon sleeves for safety. ASTA certified for complete compliance with BS 1363. . Base in nylon. List No.6920/13. 7221/3 7221 wired 13A FUSED RESILIENT PLUGS BS 1363/A l PACK QTY Fused at 13A – white 10 7222/WH Fused at 13A – black 10 7222/BK Live and neutral pins have moulded nylon sleeves for safety. 6 7011 7111 7211 FUSE LINKS l PACK QTY 6920/3 6920/5 6920/13 6925 3A red 100 6920/3 5A black 100 6920/5* 13A brown 100 6920/13 Spare dimmer fuse 10 6925 Type tested to BS 1362 and ASTA certified. 7222/WH 7222/BK 13A NON-INTERCHANGEABLE PLUGS l PACK QTY Fused at 13A – white 10 13NP Fused at 13A – red 10 13NPRD Only for use with Britmac non-standard sockets 13NP 2A. * Price and delivery on application. Fitted with ASTA certified fuse link marked BS 1362. SB615 flush galv. Two earthing terminals are fitted to the switches. Two earthing terminals are fitted to the switches. or SB619 dry lining Controls energy consumption in installations such as hotels by ensuring that appliances are not left on when rooms are unoccupied. SB615 flush galv. For full details of compliance with BS EN 60947-3 see Technical Data page 107. Cord outlet suitable for flexible cord up to 10mm outside diameter. Will accept door entry cards up to 86mm x 54mm x 1mm. Enables repair or routine maintenance of fans. Cord outlet suitable for flexible cord up to 10mm outside diameter. or SB619 dry lining Provides local isolation of fans with or without timers whilst the rest of the circuit remains live. SB623 flush galv. or SB619 dry lining C A P I TA L C O N T R O L Dimensions Mounting boxes 10 7 . or SB619 dry lining Fitted with knock-out position in bottom edge of plate for use with or without cord outlet. 4013/3 45A DP CONTROL SWITCHES BS EN 60669-1 4016/3 PACK QTY 45A DP control switch 5 4016 With neon indicator 5 4016/3 Dimensions Mounting boxes 4016 l 86mm x 86mm 9041 surface. 20A DP CONTROL SWITCHES l BS EN 60669-1 20A DP control switch 10 4015 Fitted with neon indicator 10 4015/3 Fitted with neon indicator and marked ’water heater‘ 10 4015/31 Dimensions Mounting boxes 4015 4015/31 PACK QTY 86mm x 86mm 9047 surface. 240V only. 32A DP CONTROL SWITCH l BS EN 60669-1 PACK QTY Fitted with neon indicator 4013/3 86mm x 86mm 9041 surface. The switch is operated by a door entry card and controls the supply to a room via a suitably rated contactor. SB655 flush galv. or SB619 dry lining Fitted with knock out position in bottom edge of plate for use with or without cord outlet. 4018 6AX TP CONTROL SWITCHES l BS EN 60669-1 BS EN 60947-3 5 4017 6AX three pole isolating switch marked with isolator and fan symbol 5 4017/1 Dimensions Mounting boxes 4017 4017/1 PACK QTY 6AX three pole isolating switch marked with isolator symbol 86mm x 86mm 9043 surface. SB655 flush galv.5A CARD SWITCH l PACK QTY 5A card switch Dimensions Mounting boxes 5 4018 86mm x 94mm 9047 surface. Faceplate marked ‘cooker’ 4520/1 4520/31 Dimensions 168mm x 114mm Mounting boxes 9052 surface or 9338/GV flush 4520/1 50A DP COOKER CONTROL UNITS l PACK QTY Faceplate marked ‘cooker’ 1 4523 Faceplate marked ‘cooker’ and fitted with neon indicator 1 4523/3 Blank Faceplate 1 4211/BLANK Dimensions 165mm x 178mm Mounting boxes For ‘retro fit’ applications – allows use of original flush box C A P I TA L C O N T R O L ● 8 Durable white powder coated metal faceplate. 45A DP COOKER CONTROL UNITS BS 4177 & BS 1363 l PACK QTY 45A DP main switch and 13A switch socket outlet. 4506 4507 4506 rear view . or SB632 dry lining Cable knock-out in cover prevents access to terminals before outgoing cable is fitted. 4523/3 45A CABLE OUTLETS l BS 5733 With terminals and cable clamp PACK QTY 10 4506 10 4507 Terminals will accept 2 x 10mm2 cable With cable clamp Cable clamp will accept 1 x 16mm2 through cable Dimensions 86mm x 86mm Mounting boxes 9041 surface. SB615 flush galv. SB625 flush galv. Two earth terminals are fitted. Faceplate marked ‘cooker’ 1 45A DP main switch and 13A switch socket with 1 neon indicators.45A DP ‘SLIM LINE’ COOKER CONTROL UNITS BS 4177 & BS 1363 l PACK QTY 45A DP main switch and 13A switch socket outlet. Separate double pole switching for both cooker and socket outlet. Faceplate marked ‘cooker’ 4521/1 4521/31 Dimensions 146mm x 86mm Mounting boxes 9054 surface. or SB629 dry lining ● ● 4521/31 ● ● Same plate size as standard twin socket. Large capacity tunnel terminals on live and neutral take up to 10mm2 cable. Faceplate marked ‘cooker’ 1 45A DP main switch and 13A switch socket with 1 neon indicators. Padlocking in ‘off’ or ‘on’ position in all surface mounting switches. ● ● ● ● ● 4513/WH On and off markings give positive indication of contact position. 4075 rear view 32A TP & N CONTROL SWITCHES BS EN 60669-1 BS EN 60947-3 l PACK QTY Surface metalclad switch with neon indicator Unit accommodates up to 6mm2 cable. 25A (12kW/16HP max).5mm2 max with 11mm diameter max outer sheath.20A CORD OUTLET l BS 5733 WHERE APPLICABLE PACK QTY With cable clamp 10 4075 Dimensions 86mm x 86mm Mounting boxes 9047 surface. SB655 flush galv. See pages 36 and 55 for further details. Internal shrouding of live terminals. Back box not supplied. or SB619 dry lining Outgoing cable 2. SB625 flush galv. 1 4513/WH Surface metalclad switch with neon indicator Unit accommodates up to 16mm2 cable. Terminal capacity 16mm2 on all switches Dimensions 4513/WH 142mm x 82mm x 51mm 4514/WH 173mm x 122mm x 74mm 4515/WH 207mm x 146mm Mounting box 9224/BG for flush mounting unit (4515/WH) 4513/WH Utilisation category to BS EN 60947-3 AC 22. Neon indicator with all versions which can be fitted in upper/lower terminals. 1 4514/WH Flush metalclad switch with neon indicator 1 4515/WH Unit accommodates up to 16mm2 cable. 415V. or SB629 dry lining BS EN 60947-3 rating 240V 50A category of duty AC22. 4514/WH BS EN 60669-1 l PACK QTY 50A DP control switch 5 4500 Faceplate marked ’cooker‘ 5 4500/1 Fitted with neon indicator 5 4500/3 Faceplate marked ’cooker‘ and fitted with neon indicator 5 4500/31 Dimensions Mounting boxes 86mm x 146mm 9040 surface. AC 23. 4500 4500/3 C A P I TA L C O N T R O L 50A DP CONTROL SWITCHES 9 . Switches available in two sizes and flush or surface styles. 32A 415V. etc. ie 4306 with red rockers = 4306/WH/RD. computer installations. The majority of these markings are consistent in style. All of the markings offer the same high level of durability. contact our Technical Services Department. ie 4827 marked ‘fridge freezer’ = 4827/FF.4015/31. These are ideal for use in hospitals. sockets and fused connection units with red rockers are available to order. C A P I TA L P O W E R & C O N T R O L 4013/3N 10 4013/3ST RED ROCKERS l For applications where essential supply systems are in use. 4827/3FF 4827/3DW 4827/BE 4827/3SA MARKING SUFFIX MARKING SUFFIX air conditioner AC night immersion NI bell transformer BE oven OV cooker hood HD panel heater PH daytime boost DB security alarm SA dishwasher DW security light SL emergency circuit EC shower SH extractor fan EF shower pump SP freezer FZ storage heater ST fridge FR towel rail TR fridge freezer FF tumble dryer TD heater HT washing machine WM hob HB waste disposal WD humidity vent HV water cooler WC intruder alarm IA water heater WA microwave MW These popular markings are offered on a fast track service in the standard wiring accessories colour. To order any of the markings listed below. or black. 4827 with red rockers = 4827/RD. 4304/WH/RD 4827/RD 4306/WH/RD . To order add suffix to List No. add suffix to List No. or markings in blue. For price and delivery information on other markings not listed above.PRODUCT MARKING SERVICE l A wide range of markings can be added to 13A fused connection units and double pole control switches. colour and position with the standard Tampoprinted ‘water heater’ marking on List No. For Rockergrid switches with red rockers see Rockergrid section page 48. red. 1 PACK QTY input 240V 50Hz output 115V 50Hz 240V 50Hz 60W 284mm tungsten lamp 1 2402 { 2402 Dimensions 458mm x 68mm x 74mm Complies with the requirements of the IEE Wiring Regulations (BS 7671) for use in rooms containing a fixed bath or shower. ● Suitable for use for ‘Mains shavers only’. Suitable for use with 25mm x 16mm trunking. SB628 flush galv. page 15. C A P I TA L P O W E R & C O N T R O L 2 way SP For 6A ceiling switches see Capital Lighting section. ● ● ● ● Tough. BS 4533 SECTION 102.5mm Integral pattress for surface mounting.5m long. Terminals will accept up to 10mm2 cable. in white. Moulded back-plate may be used as a template. Standard pull cord/acorn is 1. Complies with the requirements of the IEE Wiring Regulations (BS 7671) for use as an isolating device. Diffuser is removed complete with lamp fitting to facilitate safer lamp changes. LIGHT & SHAVER UNIT l BS 3535 PART 1. Can be mounted to a small circular conduit box. 11 . SHAVER SUPPLY UNIT AND LIGHT & SHAVER UNIT 20VA minimum output at rated voltage.5mm diameter x 42. Rated for non-inductive loads only. Two way switch may be wired as one way. Continental. impact resistant. all-moulded construction – no need to bond extraneous metal work. ● Incorporates an automatic thermistor protection device. ● Accepts most standard British. in white. 60W lamp can be switched independently by a separate pull switch. Can be mounted to a large circular conduit box. ● Insertion of plug switches unit on. Standard pull cord/acorn is 1. 50A CEILING SWITCHES BS EN 60669-1 l PACK QTY 1 way DP with neon and mechanical indicator Mounting boxes 2167 1 2167 Integral pattress for surface mounting. American and Australian 2 pin plugs.5m long.SHAVER SUPPLY UNIT l BS 3535 PART 1 PACK QTY input 240V 50Hz 115V 50Hz output 240V 50Hz 1 2400 input 1 2400/E { 115V 50Hz output 115V 50Hz 240V 50Hz { Dimensions Mounting boxes 2400 86mm x 146mm 9053 surface. Fully rated for fluorescent or inductive loads. Suitable for use with 16mm x 16mm mini-trunking. ● 2402 backplate removed 16A CEILING SWITCHES l BS EN 60669-1 PACK QTY 1 way DP with neon indicator Dimensions Mounting boxes 2161 2163 10 2161 10 2163 68. or SB631 dry lining Complies with the requirements of the IEE Wiring Regulations (BS 7671) for use in rooms containing a fixed bath or shower. The new compact fluorescent lampholder allows domestic dwellings to have some form of energy efficient lighting. Each plate switch will accept a seek light which is housed unobtrusively in the body of the switch to help locate it in the dark – a useful aid in sheltered housing. .LIGHTING CONTROL The extensive Capital lighting range of plate switches and ceiling accessories combines modern styling with advanced safety design features. Design of the Safety lampholder body is common to both pendant and batten lampholders. 12 Wide concave rockers are easy to operate. Ensures that the lamp must be fully inserted before the lampholder contacts become ‘live’. The standard range of ceiling accessories now offers a competitive alternative to the safety range. SMOKE DETECTOR & EMERGENCY LIGHT New advanced Smoke Detector & emergency light which are combined in a ceiling rose. C A P I TA L & M I N D E R L I G H T I N G C O N T R O L Minder PIR Sensor. Courtesy – Automatic illumination of doorways to welcome visitors. Energy saving – Provides power only when movement is detected. PIR SENSORS Minder passive infra red sensors (PIR) allow for the automatic control of lighting and other equipment. Security – Automatic lighting control to deter intruders. 13 . 10A RETRACTIVE SWITCHES l BS EN 60669-1 PACK QTY 1 gang 1 way SP marked with bell symbol 10 4096/B 1 gang 2 way SP marked with bell symbol 10 4096/2WB 1 gang 2 way SP marked ’press‘ 10 4096/P Dimensions 86mm x 86mm Mounting boxes 9043 surface. as above. as above. or SB619 dry lining 4–6 gang 9048/1 surface. Available early 2004. Spare fuse provided.4009.10AX PLATE SWITCHES l BS EN 60669-1 4070 4170 4171 4175 4173 PACK QTY Seeklight 1 4009 1 gang 1 way SP 10 4070 1 gang 2 way SP 10 4170 1 gang 1 way DP 10 4171 2 gang 2 way SP 10 4172 3 gang 2 way SP 10 4173 4 gang 2 way SP 1 gang intermediate 6 gang 2 way SP 5 4174 10 4175 5 4176 Dimensions 1–3 gang 86mm x 86mm 4–6 gang 146mm x 86mm Mounting boxes 1–3 gang 9043 surface.15A 250V. SB623 flush galv. to protect the electronic components against short circuits which may occur when the lamp fails. or SB619 dry lining Fitted with a fast acting fuse type tested to BS 4265: 1977 rated at 3. List No. or SB619 dry lining ● 4096/B 4096/P ● All 86mm x 86mm and 146mm x 86mm switches have the facility to fit one seeklight assembly. List No.6925. to assist location in the dark. List No.4009. to assist location in the dark. . SB665 flush galv. ● 4176 All 86mm x 86mm and 146mm x 86mm switches have the facility to fit one seeklight assembly. or SB629 dry lining Two way switches can be wired as one way. 4192 400W DIMMER SWITCH BS 5518. SB623 flush galv. SB623 flush galv. DIMMER SWITCHES l C A P I TA L L I G H T I N G C O N T R O L ROTARY MODULES 14 PACK QTY 1 gang 250W 5 4130 2 gang 250W 5 4132 1 gang 400W 5 4190 2 gang 400W 5 4192 Dimensions 1-2 gang 86mm x 86mm Minimum installation depth 35mm ● ● 4130 Suitable for Tungsten filament lamps. BS EN 55014 l PACK QTY 2 way Dimmer 400W maximum 60W minimum 240V AC only Dimensions Mounting box 2190 1 2190 86mm x 86mm 9043 surface. Fully rated for fluorescent or inductive loads. Can be wired for normally open (N/O) or normally closed (N/C) circuits. Fully rated for fluorescent or inductive loads.1 input 240V 50Hz 2402 output 115V 50Hz 240V 50Hz { PACK QTY 1 2402 C A P I TA L L I G H T I N G C O N T R O L 1 gang 1 way SP 1 gang intermediate 4077 4177 4179 4180 l PACK QTY 60W 284mm tungsten lamp For more information on the Shaver Unit see page 11. The screwless terminals are for use with 1. Extra wide rocker makes Corinthian ideal for use in sheltered housing installations. or SB619 dry lining Fully rated for fluorescent or inductive loads.0–1. BS 4533 SECTION 102. Retractive switch can be wired for normally open (N/O) or normally closed (N/C) circuits. Variations to retractive switch are available to order. Two way switches can be wired as one way. 15 . Can be mounted to small circular conduit box. ● ● Clip-on trim conceals fixing screws. Retractive pull cord/acorn is 2m long in red. For 16A & 50A ceiling switches see Capital Power & Control section.5mm dia x 42. page 11. Standard pull cord/acorn is 1. SHAVER SUPPLY UNIT BS 3535 PART 1 input 240V 50Hz input 115V 50Hz PACK QTY output 115V 50Hz 240V 50Hz { output { 115V 50Hz 240V 50Hz 1 2400 1 2400/E LIGHT & SHAVER UNIT BS 3535 PART 1.6A ‘CORINTHIAN’ PLATE SWITCHES BS EN 60669-1 1 gang 2 way SP 10 5170 2 gang 2 way SP 10 5172 3 gang 2 way SP 10 5173 1 gang intermediate 10 5175 10 5177 1 gang retractive Dimensions Mounting boxes 5170 5172 trim removed 86mm x 86mm 9043 surface. Retractive switches can be wired for normally open (N/O) or normally closed (N/C) circuits.5mm Complete with pattress for surface mounting.5mm2 or 3/029" PVC insulated cable. SB623 flush galv. 2147 10A ARCHITRAVE SWITCHES l BS EN 60669-1 PACK QTY 10 4077 1 gang retractive SP marked with bell symbol 10 4097/B 1 gang retractive SP marked ’press‘ 10 4097/P 1 gang 2 way SP 10 4177 2 gang 2 way SP 10 4178 1 gang 1 way DP 10 4179 10 4180 Dimensions 4097/B 4097/P 4178 1 2 Mounting boxes 1 2 gang gang gang gang 32mm x 86mm 32mm x 146mm 4005 surface or 9257/BG flush 4006 surface or 9258/BG flush Two way switches can be wired as one way. 6A CEILING SWITCHES l BS EN 60669-1 PACK QTY 1 way SP 10 2041 2 way SP 10 2141 10 2147 Retractive SP Dimensions Mounting boxes 2041 68. Two way switch can be wired as one way.5m long in white.Fully rated for fluorescent or inductive loads. 0mm cable. Base diameter 81mm. 10 5855/S9 With 12" cord.5kg.5kg. loop in and protective earth. Fixing centres 50. Base diameter 92mm. ● ● ● 5861 16 With 6" cord.5mm cable.75mm2 twin core circular cord to BS 6141 for service loads up to 2. Fixed terminal strip on batten lampholder accepts 1. 10 5855/S12 Cord supplied is heat resistant 0. 5850 ● ● 5851 ‘Wipe clean’ contacts avoid lamp seizure to pins making for safe and easy lamp replacement. standard ceiling rose 3443 and safety lampholder 5850. heavy duty ceiling rose 5861 and safety lampholder 5850. neutral. standard ceiling rose 3443 and safety lampholder 5850. ● Cord grip prevents strain on the terminal wiring. 10 5855/S With 9" cord. Home office shield supplied with the safety batten lampholder. Base diameter 92mm.5kg.SAFETY LAMPHOLDERS l BS EN 61184. loop in and protective earth. 5855/S SAFETY CEILING ROSE l BS 67 PACK QTY Safety ceiling rose 5860 10 5860 10 5861 Terminals for live. supplied with appropriate length of heat resistant 0.8mm. standard ceiling rose 3443 and safety lampholder 5850.5850). Fixing centres 50. Cord grip on pendant lampholder prevents strain on the terminal wiring.75mm2 twin core circular cord to BS 6141 for service loads up to 2. neutral. Can be mounted on circular conduit box. Integral pattress for surface mounting. loop in and protective earth. Heavy duty ceiling rose Terminals for live. T2 RATING PACK QTY Safety pendant lampholder 20 5850 Safety batten lampholder 1 5851 Home office shield 10 5801 Fixed terminals on pendant lampholder accept 1. For service loads up to 2. . C A P I TA L L I G H T I N G C O N T R O L 5855 10 5856 With 6" cord. ● Two screw cover fixing giving strong secure fixing and automatic earthing of decorative luminaires.8mm. Batten lampholder has terminals for live. 15kg load capacity. Fixed terminal strip accepts 1.5mm cable. 5801 SAFETY PENDANT SETS l PACK QTY With 6" cord 10 5855 With 9" cord 10 5855/9 With 12" cord 10 5855/12 Comprises safety ceiling rose (List No. neutral.5860) and pendant lampholder (List No. T2 RATING 3410 3420 Batten lampholder. 3432 STANDARD PENDANT SETS & LAMPHOLDERS BS 67 & BS EN 61184. seperate 4 way terminal block with Home Office skirt ● ● ● ● ● l PACK QTY 10 3432 Lampholder is fitted with heat-resistant tails.8mm fixing centres.75mm2 twin core circular cord. 3422 fitted with heat resistant tails. integral terminal block with Home Office skirt 10 3422 Dimensions ● ● ● ● ● 3422 l PACK QTY 84mm x 162mm x 140mm 50. ● 3442 3450 Lampholder is constructed from one-piece thermoplastic interior. supplied with appropriate length of heat resistant 0. Non-rising terminals. Will accept G24 4 pin plug in lamp.8mm fixing centres. T2 RATING Angle batten lampholder. T2 rating with spring plungers 10 3442 Pendant set with 6” cord 10 3450 Pendant set with 9” cord 10 3450/9 Pendant sets comprise ceiling rose (List No 3443) and pendant lampholder (List No. 3 sets of knockouts are supplied on units with integral terminal block. Non-rising skirt. T2 RATING l PACK QTY Pendant lampholder. 3 terminal direct wiring with short skirt 10 3410 Batten lampholder. STANDARD STRAIGHT BATTEN LAMPHOLDERS BS EN 61184. Supplied with integral backplate. C A P I TA L L I G H T I N G C O N T R O L STANDARD ANGLE BATTEN LAMPHOLDERS 17 . 3442). Non-stick skirt. Non-rising terminals. 50. See page 112 for technical details. seperate 4 way terminal block with Home Office skirt 10 3412 Batten lampholder.LOW ENERGY LAMPHOLDERS l 10/13W LOW ENERGY LAMPHOLDERS FOR 4 PIN CFLs PACK QTY 6” pendant set with compact fluorescent lampholder 1 3450/CFL 9” pendant set with compact fluorescent lampholder 1 3450/9CFL Compact fluorescent lampholder 1 3442/CFL ● ● 3450/CFL ● Lampshade requires 42mm diameter. 3420. integral terminal block with short skirt 10 3420 Batten lampholder. 3412 BS EN 61184. 3463/BK ANCILLIARY ITEMS l C A P I TA L L I G H T I N G C O N T R O L PACK QTY 18 3401 3402 7410RD 6900 7697 Replacement standard short skirt 50 3401 Replacement standard Home Office skirt 50 3402 1. 50. red 1 7410RD Ceiling Switch acorn. .8mm fixing centres. white 1 7410WH Neon indicator for 50A ceiling switch 1 7697 APPLEBY PHOTO CELL l PACK QTY 10A dusk till dawn sensor (70 lux) mounted in box 75 x 75 x 50mm 1 TNS/1/BK 10A dusk till dawn sensor (70 lux) mounted in box 100 x 100 x 50mm 1 TNS/2/BK 10A dusk till dawn sensor (70 lux) mounted in box 150 x 150 x 50mm 1 TNS/3/BK ● ● TNS/1/BK Provides a facility to remotely switch lighting at a pre-set level of light (70 lux). 3 sets of knockouts.STANDARD CEILING ROSE l BS 67 PACK QTY Ceiling rose with integral terminal block ● ● ● ● 10 3443 2 Terminals accept up to 1. Enclosure is rated at IP55. black 10 3462/BK 30A 3 terminal junction box. Shutters on cover close any entry holes not in use. black 10 3463/BK ● ● ● 3462/WH l Slotted pillar-type terminals accept a maximum 4 x 4. white 10 3463/WH 30A 3 terminal junction box.5mm cable. white 10 3462/WH 20A 4 terminal junction box.5m long white pull cord & white acorn 1 6900 2m long red pull cord & red acorn 1 6900/1RD 2m long white pull cord with red acorn 1 6900/1 100m ball of white pull cord 1 6900/2 100m ball of red pull cord 1 6900/2RD Ceiling Switch acorn. 3443 STANDARD JUNCTION BOXES BS 6220 PACK QTY 20A 4 terminal junction box. clear symbols indicate which entries are open and closed.0mm2 (30A) or 4 x 1.5mm2 (20A) twin and earth cables. Separate earth terminals with 6mm2 capacity. The unit will stay in standby mode until power supply is resumed. Minder 280° offers rear-field “anti-creep” protection. allowing safe convenient movement around you home ● Dusk to dawn feature prevents activation of the emergency light when power failures occur during daylight hours. Minder 90° and 220˚ offer rear-field “anti-creep” protection. Full technical information . so it is inconspicuous and aesthetically pleasing ● No batteries required. fully sealed. -40° Sensor head can be swivelled horizontally +/-65° Can be wall or ceiling mounted.5%obs eliminates most nuisance alarms ● Upon failure of your mains electricity supply either by power cut or fire. tamper proof unit 6999 shown with supplied blanking plug MINDER LIGHTING CONTROL 6999 shown with supplied safety lampholder and 6” flex l PACK QTY Full technical information . maintenance free.see page 109 19 . ● Alarm sounder is set to approximately 85 decebels ● A new and unique product comprising of an advanced ionisation type smoke detector and emergency light. or until darkness falls. together with a signalling unit combined into a domestic ceiling rose ● High performance 2. when it will activate your emergency lighting ● Replaces an existing ceiling rose.MINDER 90° AND MINDER 220° SENSORS IP55 90° Sensor 220° Sensor Dimensions ● ● ● ● Dimensions ● ● 1 6878 l PACK QTY 280° Sensor 6878 6852 Minder 90° and Minder 220° can be swivelled vertically +90°.65° Can be wall or ceiling mounted. the emergency light incorporated in the unit will illuminate an average 3 metre square room for a period up to 2 hours. IP55 ● 1 102mm x 102mm x 182mm MINDER 280° SENSOR ● l PACK QTY 1 6880 102mm x 102mm x 182mm Minder 280° can be swivelled vertically +90° -40° Sensor head can be swivelled horizontally +/.see page 108 MINDER EMERGENCY LIGHT & SMOKE DETECTOR BS 5446 PART1 Minder emergency light and smoke detector complete with Safety lampholder and 6” flex 1 6999 ● Smoke detector contains 10 year soldered in rechargeable lithium cells for mains power failure back up. .Easily removed ‘ears’ to allow for alternative flat plate option. 20 Interior allows wiring to be terminated without securing front plate. Fascia plate is secured after fitting to avoid accidental damage during the installation or during later decoration. Elongated grid fixing hole allows correct alignment of the interior if the installation box has not been mounted squarely. Note: do not remove ‘ears’ for low profile option. control and lighting accessories. With no compromise between style and function. P L AT I N U M L O W P R O F I L E & F L AT P L AT E 21 . the Platinum range is slim.An extensive range of power. available in a range of high quality metal finishes as either screw-fit flat plate or clip-on screwless low profile plate. stylish and packed with solid Crabtree engineering. 2 gang 88mm x 148mm Installation Box depth 35mm ● All sockets are supplied as dual earth. ie 13A 2 gang DP Switched Socket Interior in Satin Chrome = 1316/1SC/WH ie 2 gang Switched Socket Plate in Satin Chrome = 7506/SC ● All interiors are supplied with appropriate fixing grids ● Other finishes are available . 13A FUSED CONNECTION UNIT 1832/ 13PB 7508/ 3PB 1832/ 1HPC 7508/ HPC BS 1363 l 13A switched fuse connection unit Interior Plate 1832/1_ _ 7508/_ _ 13A switched fuse connection unit with neon Interior Plate 1832/13_ _ 7508/3_ _ 13A switched FCU with cord outlet Interior Plate 1837/1_ _ 7533/_ _ 13A switched FCU with cord outlet & neon Interior Plate 1837/13_ _ 7533/3_ _ 2A round pin unswitched socket Interior Plate 1075/1_ _ 7560/_ _ 5A round pin switched socket Interior Plate 1240/1_ _ 7578/_ _ 5A round pin unswitched socket Interior Plate 1340/1_ _ 7579/_ _ 15A round pin switched socket Interior Plate 1272/1_ _ 7515/_ _ Dimensions 1 gang 88mm x 88mm Installation Box depth 35mm P L AT I N U M L O W P R O F I L E 2.Interior Plate Clip on location holes LOW PROFILE ● Standard Finishes: l HPC . if required with White moulded insert add /WH .Polished Brass .Satin Chrome .Highly Polished Chrome . 5 & 15A ROUND PIN SOCKET 22 1272/ 1SC/WH 7515/ SC l Dimensions 1 gang 88mm x 88mm Installation Box depth 35mm 6A TP ISOLATOR SWITCH 6A triple pole isolator switch BS EN60669-1 l Interior Plate 1017/1_ _ 7505/_ _ Interior Plate 1410/1* 7510/_ _ Dimensions 1 gang 88mm x 88mm Installation Box depth 35mm SHAVER SUPPLY UNIT shaver supply unit 1017/ 1HPC 7505/ HPC l Dimensions 88mm x 148mm Installation Box depth 55mm * Black moulded insert as standard.Black moulded insert SC/WH .White moulded insert PB ● Indicate the finish you require by adding suffix to List No.Black moulded insert 13A SWITCHED SOCKET 1314 / 1SC / WH 7504 / SC 1316 / 1PB 7506 / PB BS 1363 l 1 gang DP switched socket Interior Plate 1314/1_ _ 7504/_ _ 1 gang DP switched socket with neon Interior Plate 1314/13_ _ 7504/3_ _ 2 gang DP switched socket Interior Plate 1316/1_ _ 7506/_ _ 2 gang DP switched socket with neons Interior Plate 1316/13_ _ 7506/3_ _ Dimensions 1 gang 88mm x 88mm.see Technical section page 112 ● ● 1316/1SC/WH 7506/SC Interior to box fixing screws . 25mm 3 gang DIMMER-ROTARY l 1 gang 250W 7250/D1_ _ 2 gang 250W 7250/D2_ _ 1 gang 400W 7400/D1_ _ 2 gang 400W 7400/D2_ _ Suitable for Tungsten Loads. Other options available please contact Technical Services.LOW PROFILE BS EN60669-1 l 10AX PLATE SWITCH 1170/ 1HPC 7501/ HPC 1172/ 1PB 7502/ PB l 1 gang 2 way 10AX switch Interior Plate 1170/1_ _ 7501/_ _ 1 gang 1 way 10A retractive switch Interior Plate 1096/1_ _ 7501/_ _ 2 gang 2 way 10AX switch Interior Plate 1172/1_ _ 7502/_ _ 3 gang 2 way 10AX switch Interior Plate 1173/1_ _ 7503/_ _ Dimensions 1 gang 88mm x 88mm Installation Box depth 16mm 1 & 2 gang. 7250/ D1SC 7400/ D2PB Dimensions 1 & 2 gang 88mm x 88mm Installation Box depth 35mm 20A DP CONTROL SWITCH 20A DP control switch Interior Plate 1011/1_ _ 7520/_ _ 20A DP control switch with neon Interior Plate 1011/13_ _ 7520/3_ _ 32A DP CONTROL SWITCH 1011/ 13PB 7520/ 3PB 1012/ 13SC 7532/ 3SC 1512/ 1HPC 7545/ HPC BS EN60669-1 l 32A DP control switch Interior Plate 1012/1_ _ 7532/_ _ 32A DP control switch with neon Interior Plate 1012/13_ _ 7532/3_ _ 45A DP CONTROL SWITCH 1512/ 13PB 7545/ 3PB BS EN60669-1 l BS EN60669-1 l 45A DP control switch Interior Plate 1512/1_ _ 7545/_ _ 45A DP control switch with neon Interior Plate 1512/13_ _ 7545/3_ _ Dimensions 1 gang 88mm x 88mm 45A DP COOKER CONTROL UNIT l BS 4177 & BS1363 Cooker control unit Interior Plate 1522/1_ _ 7546/_ _ Cooker control unit with neon Interior Plate 1522/13_ _ 7546/3 _ _ 1 gang communication module frame Interior Plate 1091/1 7507/_ _ 2 gang communication module frame Interior Plate 1092/1 7509/_ _ Dimensions 88mm x 148mm 1522/ 13PB 7546/ 3PB Installation Box depth 35mm COMMUNICATION PLATES l Communication ‘Datapak’ accessories shown on page 71 BLANK PLATES 1091/1 7507/ SC 1092/1 7509/ HPC l 1 gang blank plate 1091/1 + 7575/_ _ 2 gang blank plate 1092/1 + 7577/_ _ Dimensions 1 gang 88mm x 88mm 2 gang 88mm x 148mm P L AT I N U M L O W P R O F I L E Installation Box depth 35mm Installation Box depth 35mm 23 . Stainless Steel .White moulded insert PB ● Indicate the finish you require by adding suffix to List No. 13A FUSED CONNECTION UNIT 1832/ 13PSS 8508/ 3PSS 1832/ 1PB 8508/ PB BS 1363 l 13A switched fuse connection unit Interior Plate 1832/1_ _ 8508/_ _ 13A switched fuse connection unit with neon Interior Plate 1832/13_ _ 8508/3_ _ 13A switched FCU with cord outlet Interior Plate 1837/1_ _ 8533/_ _ 13A switched FCU with cord outlet & neon Interior Plate 1837/13_ _ 8533/3_ _ 2A round pin unswitched socket Interior Plate 1075/1_ _ 8560/_ _ 5A round pin switched socket Interior Plate 1240/1_ _ 8578/_ _ 5A round pin unswitched socket Interior Plate 1340/1_ _ 8579/_ _ 15A round pin switched socket Interior Plate 1272/1_ _ 8515/_ _ Dimensions 1 gang 86mm x 86mm Installation Box depth 35mm P L AT I N U M F L AT P L AT E 2.Plate Interior Plate to grid fixing screws FLAT PLATE ● l Standard Finishes: PSS .see Technical Data page 112 ● ● 1316/13PB 8506/3PB Interior to box fixing screws .Polished Brass .Black moulded insert 13A SWITCHED SOCKET 1314 / 13SS/ WH 8504 / 3SS 1316 / 1PSS 8506 / PSS BS 1363 l 1 gang DP switched socket Interior Plate 1314/1_ _ 8504/_ _ 1 gang DP switched socket with neon Interior Plate 1314/13_ _ 8504/3_ _ 2 gang DP switched socket Interior Plate 1316/1_ _ 8506/_ _ 2 gang DP switched socket with neons Interior Plate 1316/13_ _ 8506/3_ _ Dimensions 1 gang 86mm x 86mm. 5 & 15A ROUND PIN SOCKET 1272/ 1PB 8515/ PB l Dimensions 1 gang 86mm x 86mm Installation Box depth 35mm 6A TP ISOLATOR SWITCH 6A triple pole isolator switch l BS EN60669-1 Interior Plate 1017/1_ _ 8505/_ _ Interior Plate 1410/1* 8510/_ _ Dimensions 1 gang 86mm x 86mm Installation Box depth 35mm SHAVER SUPPLY UNIT Shaver supply unit 1017/ 1PSS 8505/ PSS l Dimensions 86mm x 146mm Installation Box depth 55mm * Black moulded insert as standard. if required with White moulded insert add /WH 24 .Polished Stainless Steel .Black moulded insert SS/WH . ie 13A 2 gang DP Switched Socket Interior + Neon in Polished Brass = 1316/13PB ie 2 gang Switched Socket Plate + Neon in Polished Brass = 8506/3PB ● All interiors are supplied with appropriate fixing grids ● Other finishes available . 2 gang 86mm x 146mm Installation Box depth 35mm ● All sockets are supplied as dual earth. Other options available please contact Technical Services.FLAT PLATE BS EN60669-1 l 10AX PLATE SWITCH 1170/ 1SS 8501/ SS 1173/ 1PB 8503/ PB l 1 gang 2 way 10AX switch Interior Plate 1170/1_ _ 8501/_ _ 1 gang 1 way 10A retractive switch Interior Plate 1096/1_ _ 8501/_ _ 2 gang 2 way 10AX switch Interior Plate 1172/1_ _ 8502/_ _ 3 gang 2 way 10AX switch Interior Plate 1173/1_ _ 8503/_ _ Dimensions 1 gang 86mm x 86mm Installation Box depth 16mm 1 & 2 gang. 8250/ D1PSS 8400/ D2PB Dimensions 1 & 2 gang 86mm x 86mm Installation Box depth 35mm 20A DP CONTROL SWITCH 20A DP control switch Interior Plate 1011/1_ _ 8520/_ _ 20A DP control switch with neon Interior Plate 1011/13_ _ 8520/3_ _ 32A DP CONTROL SWITCH 1011/ 13SS 8520/ 3SS 1012/ 1PSS 8532/ PSS 1512/ 13PB 8545/ 3PB BS EN60669-1 l 32A DP control switch Interior Plate 1012/1_ _ 8532/_ _ 32A DP control switch with neon Interior Plate 1012/13_ _ 8532/3_ _ 45A DP CONTROL SWITCH 1012/ 13PB 8532/ 3PB BS EN60669-1 l BS EN60669-1 l 45A DP control switch Interior Plate 1512/1_ _ 8545/_ _ 45A DP control switch with neon Interior Plate 1512/13_ _ 8545/3_ _ Dimensions 1 gang 86mm x 86mm Installation Box depth 35mm l BS 4177 & BS1363 Cooker control unit Interior Plate 1522/1_ _ 8546/_ _ Cooker control unit with neons Interior Plate 1522/13_ _ 8546/3 _ _ 1 gang communication module frame Interior Plate 1091/1 8507/_ _ 2 gang communication module frame Interior Plate 1092/1 8509/_ _ Dimensions 86mm x 146mm Installation Box depth 35mm 1522/ 13PB 8546/ 3PB COMMUNICATION PLATES l Communication ‘Datapak’ accessories shown on page 71 BLANK PLATES 1091/1 8507/ PB 1092/1 8509/ SS l 1 gang blank plate 1091/1 + 8585/_ _ 2 gang blank plate 1092/1 + 8577/_ _ Dimensions 1 gang 86mm x 86mm. 25mm 3 gang DIMMER-ROTARY l 250W 1 gang 8250/D1_ _ 250W 2 gang 8250/D2_ _ 400W 1 gang 8400/D1_ _ 400W 2 gang 8400/D2_ _ Suitable for Tungsten Loads. 2 gang 86mm x 146mm P L AT I N U M F L AT P L AT E 45A DP COOKER CONTROL UNIT Installation Box depth 35mm 25 . NO OUTER TRIM 10AX 1 way 10AX 2 way 20A 1 way 20A 2 way 20A double pole 20A intermediate 4430/7HPC 4450/7PB 4460/7PSS 4530/7SC 4550/7SS l 4430/7_ 4530/7_ 4450/7_ 4550/7_ 4460/7_ 4535/7_ All the following Switches are available in Satin Chrome (SC).PLATINUM GRID Switch Grid plate Clip on location holes Complete Assembly 4430/7PB Grid yoke 1901 Grid yoke to box fixing screws 7711/PB GRID PLATES . and Polished Stainless Steel (PSS) Installation Box depth 35mm Rockergrid items shown on page 48 & 49 will not fit onto the above plates. Polished Brass (PB) and Polished Stainless Steel (PSS) GRID YOKES 1 2 3 4 6 8 gang gang gang gang gang gang l yoke yoke yoke yoke yoke yoke 1901 1902 1903 1904 1906 1908 P L AT I N U M G R I D When mounting grid yokes for use with the flat plate. Stainless Steel (SS). 26 _ _ _ _ _ _ .LOW PROFILE Plate Plate Plate Plate Plate Plate for for for for for for 1 2 3 4 6 8 gang gang gang gang gang gang Dimensions 7711/SC 7713/PB _ _ _ _ _ _ All the following plates are available in Satin Chrome (SC). Polished Brass (PB). Polished Brass (PB) and Highly Polished Chrome (HPC) Plate Plate Plate Plate Plate Plate for for for for for for 1 2 3 4 6 8 gang gang gang gang gang gang l grid grid grid grid grid grid Dimensions 8714/SS 7711/_ 7712/_ 7713/_ 7714/_ 7716/_ 7718/_ 1-2 gang 88mm x 88mm 3-4 gang 148mm x 88mm 6-8 gang 148mm x 148mm GRID PLATE .FLAT PLATE 8712/PSS l grid grid grid grid grid grid 8711/_ 8712/_ 8713/_ 8714/_ 8716/_ 8718/_ _ _ _ _ _ _ 1-2 gang 86mm x 86mm 3-4 gang 146mm x 86mm 6-8 gang 146mm x 146mm All the following plates are available in Stainless Steel (SS). remove the outer fixing ears 1901 1903 GRID SWITCHES . Highly Polished Chrome (HPC). Stainless Steel (SS/WH). 4450/6SC (black surround) Installation Box depth 35mm P L AT I N U M R O C K E R G R I D F O R P L AT I N U M Plate Plate Plate Plate Plate Plate 8514/SS _ _ _ _ _ _ 1-2 gang 88mm x 88mm 3-4 gang 148mm x 88mm 6-8 gang 148mm x 148mm GRID PLATE S .LOW PROFILE Plate Plate Plate Plate Plate Plate for for for for for for 1 2 3 4 6 8 gang gang gang gang gang gang Dimensions 7511/SC 7513/PB 7511/_ 7512/_ 7513/_ 7514/_ 7516/_ 7518/_ All the following plates are available in Satin Chrome (SC).e. Highly Polished Chrome (HPC). Polished Brass (PB) and Highly Polished Chrome (HPC) for for for for for for 1 2 3 4 6 8 gang gang gang gang gang gang l grid grid grid grid grid grid Dimensions 8511/_ 8512/_ 8513/_ 8514/_ 8516/_ 8518/_ _ _ _ _ _ _ 1-2 gang 86mm x 86mm 3-4 gang 146mm x 86mm 6-8 gang 146mm x 146mm All the following plates are available in Stainless Steel (SS). Polished Brass (PB) and Polished Stainless Steel (PSS) 4530/6HPC 4550/6PB 4460/6PSS 4450/6SC/WH 4430/6SS/WH Other moulding finishes available as made to order i. Polished Brass (PB) and Polished Stainless Steel (PSS) GRID YOKES 1 2 3 4 6 8 gang gang gang gang gang gang l yoke yoke yoke yoke yoke yoke 1901 1902 1903 1904 1906 1908 When mounting Grid yokes for use with the Flat plate.ROCKERGRID FOR PLATINUM RANGE Switch Complete Assembly Grid plate Clip on location holes 4530/6HPC Grid yoke 1901 7511/HPC Grid yoke to box fixing screws GRID PLATES . remove the outer fixing ears 1901 1903 GRID SWITCHES l 10AX 1 way 10AX 2 way 20A 1 way 20A 2 way 20A double pole 20A intermediate 4430/6_ 4530/6_ 4450/6_ 4550/6_ 4460/6_ 4535/6_ _ _ _ _ _ _ All the following Switches are available in Satin Chrome (SC/WH). 27 .FLAT PLATE 8512/PSS l grid grid grid grid grid grid Rockergrid items shown on page 48 & 49 will fit onto the above plates. Highly Polished Chrome (HPC) and Polished Brass (PB) Installation Box depth 35mm One fixing key supplied per pack of 5 5430/PB 5550/SC 5552/HPC . remove the outer fixing ears 1901 1903 TOGGLE SWITCHES l 10AX 2 way single pole 20A 2 way single pole 20A 2 way and off single pole 5430/_ _ 5550/_ _ 5552/_ _ All the following switches are available in Satin Chrome (SC).TOGGLE SWITCHES AND PLATES Switch Toggle fixing screw Grid yoke Complete Assembly Grid plate 5430/PB Outer locking ring 1901 Grid yoke to box fixing screws 8T01/PB Plate to yoke fixing screws TOGGLE PLATES-LOW PROFILE Plate Plate Plate Plate for for for for 1 2 3 4 gang gang gang gang grid grid grid grid Dimensions l 7T01/_ 7T02/_ 7T03/_ 7T04/_ _ _ _ _ 1-2 gang 88mm x 88mm 3-4 gang 148mm x 88mm All the following plates are available in Satin Chrome (SC). Polished Brass (PB) and Highly Polished Chrome (HPC) P L AT I N U M T O G G L E S W I T C H E S A N D P L AT E S 7T01/SC 28 7T03/HPC All plates come complete with outer locking ring in appropriate finish TOGGLE PLATES-FLAT PLATE Plate Plate Plate Plate for for for for 1 2 3 4 gang gang gang gang grid grid grid grid Dimensions l 8T01/_ 8T02/_ 8T03/_ 8T04/_ _ _ _ _ 1-2 gang 86mm x 86mm 3-4 gang 146mm x 86mm All the following plates are available in Stainless Steel (SS). Polished Brass (PB) and Polished Stainless Steel (PSS) All plates come complete with outer locking ring in appropriate finish 8T02/PSS 8T04/PB GRID YOKES 1 2 3 4 gang gang gang gang l yoke yoke yoke yoke 1901 1902 1903 1904 When mounting grid yokes for use with the flat plate. COMPLETE ASSEMBLIES FINISHES AVAILABLE l LOW PROFILE FLAT PLATE SC/WH Satin Chrome White interior SS/WH Stainless Steel White interior HPC Highly Polished Chrome Black interior PSS Polished Stainless Steel Black interior PB Polished Brass Black interior PB Polished Brass Black interior Fully assembled products come complete with display packaging 13A SWITCHED SOCKET OUTLET l LOW PROFILE FLAT PLATE 1 gang DP switched socket 7314/_ _ 8314/_ _ 2 gang DP switched socket 7316/_ _ 8316/_ _ Dimensions 88mm x 88mm 148mm x 88mm 86mm x 86mm 146mm x 86mm 1 gang 2 gang Installation Box depth 35mm 8314/PB 7316/SC/WH 13A FUSED CONNECTION UNIT l LOW PROFILE FLAT PLATE DP switched 7832/_ _ 8832/_ _ DP switched with neon 7832/3_ _ 8832/3_ _ Dimensions 88mm x 88mm 86mm x 86mm LOW PROFILE FLAT PLATE 1 gang 2 way 7170/_ _ 8170/_ _ 2 gang 2 way 7172/_ _ 8172/_ _ 3 gang 2 way 7173/_ _ 8173/_ _ Dimensions 88mm x 88mm 86mm x 86mm Installation Box depth 35mm 7832/3PB 10AX PLATE SWITCH l Installation Box depth 1 & 2 gang 16mm. 3 gang 25mm 8170/PSS 7173/SC 20A DP CONTROL SWITCH FLAT PLATE 20A DP control switch 7011/_ _ 8011/_ _ 20A DP control sw + neon 7011/3_ _ 8011/3_ _ Dimensions 88mm x 88mm 86mm x 86mm Installation Box depth 35mm 8011/3SS 7011/HPC l LOW PROFILE P L AT I N U M C O M P L E T E A S S E M B L I E S 8832/3PSS 29 . Satin Chrome 30 Highly Polished Chrome Bronze Oyster Gold Unique labyrinth switch design minimises visible arc flash and prevents front access to live parts whilst wide concave rockers are easy to operate. . METAL PLATE The sophistication of Satin Chrome and Highly Polished Chrome along with the elegance of Bronze and Oyster Gold finishes provide stylish options to specifiers of a comprehensive matching range of wiring accessories. C A P I TA L M E TA L P L AT E 31 . or SB619 dry lining 4831/SC 4832/3BZ All fused connection units: Fused on the line side with 13A fuse link ASTA certified and marked to BS 1362. SB615 flush galv. Cord outlet suitable for flexible cord up to 10mm outside diameter. 13A FLUSH FUSED CONNECTION UNITS WITH METAL ROCKER l BS 1363 PACK QTY DP switched 10 4832/_ _/9 DP switched with neon indicator 10 4832/3_ _/9 DP switched with cord outlet 10 4837/_ _/9 DP switched with cord outlet & neon indicator 10 4837/3_ _/9 Dimensions 86mm x 86mm Mounting boxes 9221/BG surface. For spare fuse links see page 6. Indicate the finish you require by adding suffix to List No. 13A FLUSH SOCKET OUTLETS WITH METAL ROCKERS l BS 1363 PACK QTY 1 gang SP switched 10 4314/_ _/9 2 gang SP switched 5 4316/_ _/9 1 gang SP switched fitted with neon indicator 10 4314/3_ _/9 2 gang SP switched fitted with neon indicator 5 4316/3_ _/9 Dimensions 4314/YR/9 4316/3SC/9 1 gang 86mm x 86mm 2 gang 146mm x 86mm Mounting boxes 1 gang 9221/BG surface.ie: Double Pole 4316/3SC/9 = 4316/3DSC/9. 13A FLUSH FUSED CONNECTION UNITS BS 1363 Unswitched 10 4831/_ _ Unswitched with neon 10 4831/3_ _ DP switched 10 4832/_ _ DP switched with neon indicator 10 4832/3_ _ Unswitched with cord outlet 10 4836/_ _ DP switched with cord outlet 10 4837/_ _ C A P I TA L M E TA L P L AT E DP switched with cord outlet and neon indicator 10 4837/3_ _ Dimensions 86mm x 86mm Mounting boxes 9221/BG surface. 32 l PACK QTY . or SB629 dry lining Double Pole switched versions available to order. SB625 flush galv. Two earthing terminals are fitted to the unit. SB615 flush galv. Bronze (BZ). SB625 flush galv. Polished Stainless Steel (PSS) is available made to order. or SB619 dry lining 2 gang 9223/BG surface. 13A FLUSH SOCKET OUTLETS l BS 1363 PACK QTY 1 gang SP switched 10 4314/_ _ 2 gang SP switched 5 4316/_ _ 1 gang SP switched fitted with neon indicator 10 4314/3_ _ 2 gang SP switched fitted with neon indicator 5 4316/3_ _ 1 gang unswitched 10 8255/_ _ 2 gang unswitched 5 8257/_ _ Dimensions 8255/SC 4316/YR 1 gang 86mm x 86mm 2 gang 146mm x 86mm Mounting boxes 1 gang 9221/BG surface. and Highly Polished Chrome (HPC). ie Double pole 4314/BZ = 4314/DBZ.Add suffix D to List No. SB615 flush galv. or SB619 dry lining 2 gang 9223/BG surface. or SB629 dry lining Double pole switched versions are available to order – Add suffix D to List No. SB615 flush galv. or SB619 dry lining 4832/YR/9 4832/3BZ/9 For full specification details of finishes see Technical Data page 112.All the following list numbers are available in Satin Chrome (SC). Oyster Gold (YR). ie 4314 – 1 gang switch socket in Bronze = 4314/BZ. All the following list numbers are available in Satin Chrome (SC). ie Double pole 4214/BZ = 4214/DBZ. 13A SURFACE SOCKET OUTLETS WITH METAL ROCKERS l BS 1363 1 gang SP switched 10 4214/_ _/9 2 gang SP switched 5 4216/_ _/9 1 gang SP switched fitted with neon indicator 10 4214/3_ _/9 2 gang SP switched fitted with neon indicator 5 4216/3_ _/9 Dimensions 4214/SC/9 4216/3BZ/9 PACK QTY 1 gang 82mm x 82mm x 44mm 2 gang 142mm x 82mm x 44mm For boxes without knockouts. Double Pole switched versions available to order.Add suffix D to List No. ie 4214 – 1 gang switch socket in Bronze = 4214/BZ. 13A SURFACE FUSED CONNECTION UNITS BS 1363 Unswitched 4847/3YR 10 4841/_ _ Unswitched with neon 10 4841/3 _ _ DP switched 10 4842/_ _ DP switched with neon 10 4842/3_ _ Unswitched with cord outlet 10 4846/_ _ DP switched with cord outlet 10 4847/_ _ DP switched with cord outlet and neon 10 4847/3_ _ Dimensions 82mm x 82mm x 44mm 13A SAFETY SOCKETS – RCD PROTECTION BS 7288 l PACK QTY SURFACE 1 gang switched with neon indicator 10mA tripping current 1 4424/A01_ _ 1 gang switched with neon indicator 30mA tripping current 1 4424/A03_ _ 2 gang switched with neon indicator 10mA tripping current 1 4426/A01_ _ 2 gang switched with neon indicator 30mA tripping current 1 4426/A03_ _ Dimensions 4424/A01BZ 142mm x 82mm x 44mm See page 102 for further information. and Highly Polished Chrome (HPC). Double pole switched versions available to order – Add suffix D to List No. see page 68 .ie: Double Pole = 4216/3DSC/9. Bronze (BZ). 13A SURFACE SOCKET OUTLETS BS 1363 1 gang SP switched 10 4214/_ _ 2 gang SP switched 5 4216/_ _ 1 gang SP switched fitted with neon indicator 10 4214/3_ _ 2 gang SP switched fitted with neon indicator 5 4216/3_ _ 1 gang unswitched 10 9685/_ _ 2 gang unswitched 5 9687/_ _ Dimensions 4214/BZ l PACK QTY 4216/3SC 1 gang 82mm x 82mm x 44mm 2 gang 142mm x 82mm x 44mm For boxes without knock-outs see page 68. C A P I TA L M E TA L P L AT E 4846/SC l PACK QTY For full specification details of finishes see Technical Data page 112. All available with two earth terminals to enable installation to comply with section 607 (wiring regulations) Add suffix /TE to List No = 4416/A03SC/TE. Oyster Gold (YR). 33 . Indicate the finish you require by adding suffix to List No. All the following list numbers are available in Satin Chrome (SC). 4512/YR 4512/3SC 2A. or SB619 dry lining 2 gang 9048 surface. or SB629 dry lining See page 102 for further information. SB665 flush galv. Oyster Gold (YR). or SB629 dry lining For full specification details of finishes see Technical Data page 112. 5A. 50A DP CONTROL SWITCHES BS EN 60669-1 l PACK QTY DP switch DP switch with neon indicator Dimensions Mounting boxes 5 4512/_ _ 5 4512/3_ _ 86mm x 146mm 9040 surface. 34 . ie 2340 – 5A 3 pin switched in Satin Chrome = 2340/SC. All available with two earth terminals to enable installation to comply with section 607 (wiring regulations) Add suffix /TE to List No = 4416/A03SC/TE. or SB629 dry lining BS EN 60947-3 rating 240V 50A category of duty AC22. SB615 flush galv. Bronze (BZ).vertical 5 7162/_ _ Dimensions Mounting boxes 7161/SC PACK QTY 1 gang 86mm x 86mm 2 gang 86mm x 146mm 1 gang 9047 surface. ie 8075/BZE. SB665 flush galv. 13A SAFETY SOCKETS – RCD PROTECTION BS 7288 l PACK QTY FLUSH 1 gang switched with neon indicator 10mA tripping current 1 4414/A01_ _ 1 gang switched with neon indicator 30mA tripping current 1 4414/A03_ _ 2 gang switched with neon indicator 10mA tripping current 1 4416/A01_ _ 2 gang switched with neon indicator 30mA tripping current 1 4416/A03_ _ Dimensions Mounting boxes 4416/A03BZ 146mm x 86mm 9048 surface. For associated cable outlets see page 8. 8075/SCE 2340/BZ 15A 125V AMERICAN STANDARD FLUSH SOCKET OUTLETS l NEMA CONFIGURATION 5–15 1 gang 10 7161/_ _ 2 gang . SB625 flush galv. and Highly Polished Chrome (HPC). or SB619 dry lining * Unshuttered version available for export only – Add suffix E to List No. 15A FLUSH SOCKET OUTLETS l C A P I TA L M E TA L P L AT E PACK QTY 2A 3 pin unswitched 10 8075/_ _* 5A 3 pin switched 10 2340/_ _ 15A 3 pin switched 10 2372/_ _ Dimensions Mounting boxes 86mm x 86mm 9221/BG surface. SB655 flush galv. Indicate the finish you require by adding suffix to List No. Polished Stainless Steel (PSS) is available made to order. All the following list numbers are available in Satin Chrome (SC). (Except 6096. 10A only) Retractive switch can be wired for normally open (N/O) or normally closed (N/C) circuits. 35 . SB615 flush galv. SB615 flush galv. or SB619 dry lining C A P I TA L M E TA L P L AT E 1250W/HPC 1 gang dimmer 250W For full specification details of finishes see Technical Data page 112. or SB619 dry lining 3-4 gang 9223/BG surface. please contact Technical Services. Polished Stainless Steel (PSS) is available made to order. Dimensions 1-2 gang 86mm x 86mm Mounting boxes 1-2 gang 9223/BG surface. ie 6170 – 1 gang switch socket in Bronze = 6170/BZ. Bronze (BZ). SB623 flush galv. 3-4 gang 146 x 86mm Mounting boxes 1-2 gang 9221/BG surface. or SB629 dry lining TOGGLE SWITCHES . SB625 flush galv. or SB619 dry lining Cord outlet suitable for flexible cord up to 10mm outside diameter.FLUSH l PACK QTY 2400W/BZ 1 1250W/_ _ 1 gang dimmer 400W 1 1400W/_ _ 1 gang low voltage dimmer 400W 1 1400LV/_ _ 2 gang dimmer 250W 1 2250W/_ _ 2 gang dimmer 400W 1 2400W/_ _ 3 gang dimmer 250W 1 3250W/_ _ 4 gang dimmer 250W 1 4250W/_ _ Other options available. See pages 49 & 51. or SB619 dry lining Two earthing terminals are fitted to the switches.FLUSH BS EN 60669-1 6141/SC 6142/BZ l PACK QTY 1 gang 10A 2 way 1 6141/_ _ 2 gang 10A 2 way 1 6142/_ _ 1 gang 20A 2 way 1 6151/_ _ 1 gang 20A 2 way and Off 1 6125/_ _ 2 gang 20A 2 way 1 6152/_ _ Other options available. Dimensions 1-2 gang 86mm x 86mm. and Highly Polished Chrome (HPC). Indicate the finish you require by adding suffix to List No. 20A DP CONTROL SWITCHES l BS EN 60669-1 PACK QTY DP switch 10 4011/_ _ DP switch with neon indicator 10 4011/3_ _ DP switch with neon indicator and cord outlet 10 4014/3_ _ Dimensions Mounting boxes 86mm x 86mm 9047 surface. DIMMER SWITCHES . SB655 flush galv. SB615 flush galv. or SB619 dry lining Two way switches can be wired as one way. Fully rated for fluorescent or inductive loads. 32A DP CONTROL SWITCH l BS EN 60669-1 4011/BZ 4014/3SC PACK QTY DP switch with neon indicator Dimensions Mounting boxes 10 4012/3_ _ 86mm x 86mm 9041 surface. 10AX PLATE SWITCHES PACK QTY 1 gang 2 way 10 6170/_ _ 2 gang 2 way 10 6172/_ _ 3 gang 2 way 10 6173/_ _ 1 gang Intermediate 10 6175/_ _ 1 gang retractive (press) 10 6096/_ _ Dimensions Mounting boxes 6170/BZ 6175/BZ 6172/SC l BS EN 60669-1 86mm x 86mm 9043 surface. Oyster Gold (YR). or SB629 dry lining The metal plates listed above accept any of the Datapak range of modules. or SB619 dry lining 8094*–9040 surface. SB623 flush galv. SB655 flush galv. Bronze (BZ). or SB619 dry lining 8283/HPC 8284/SC BLANKING PLATES l BS 5733 WHERE APPLICABLE 1 gang 2 gang Dimensions 6575/YR PACK QTY 20 6575/_ _ 20 6577/_ _ 1 gang 86mm x 86mm 2 gang 146mm x 86mm 6577/BZ For full specification details of finishes see Technical Data page 112. VHF 1 8267/_ _ 2 way isolated UHF. DATAPAK COMMUNICATIONS PLATES BS 5733 WHERE APPLICABLE l PACK QTY 1 module metal plate (fitted with grid) 5 8091/_ _ 2 module metal plate (fitted with grid) 5 8092/_ _ 4 module metal plate (fitted with grid) 5 8094/_ _ Dimensions 8092/BZ fitted with modules 8092/SC fitted with modules 86mm x 86mm. Polished Stainless Steel (PSS) is available made to order. 32A TP & N CONTROL SWITCH BS 3676 TYPE TESTED TO BS EN 60947-3 l PACK QTY TP & N switch with neon indicator 1 4515/_ _ 16mm2 207mm x 146mm 9224/BG for flush mounting Terminal capacity Dimensions Mounting box See pages 9 & 55 for further details. SB615 flush galv. CO-AXIAL SOCKET OUTLETS BS 3041 WHERE APPLICABLE 8265/YR 8268/BZ l PACK QTY 1 way direct connection 10 8265/_ _ 2 way direct connection 10 8266/_ _ 1 way isolated UHF. TELEPHONE PLATES l C A P I TA L M E TA L P L AT E BS 7671 PACK QTY Telephone master 10 8283/_ _ Telephone secondary 10 8284/_ _ Dimensions 86mm x 86mm Mounting boxes 9047 surface. Indicate the finish you require by adding suffix to List No. or SB619 dry lining 4515/SC For Technical details see page 107. 36 . 8092*–9041 surface.All the following list numbers are available in Satin Chrome (SC). or SB619 dry lining Isolated units only suitable on installations with earth bond. 4 module Mounting boxes 8091*. See page 71 for full product selection details. 6AX TP CONTROL SWITCH l BS EN 60669-1 BS EN 60947-3 PACK QTY 6AX Three Pole Isolating switch 10 6017/_ _ Dimensions 86mm x 86mm Mounting boxes 9043 surface. 1 & 2 module 86mm x 146mm. and Highly Polished Chrome (HPC). ie 8265 Co-axial socket in Bronze = 8265/BZ. Oyster Gold (YR). SB625 flush galv. SB655 flush galv. VHF 1 8268/_ _ Dimensions 86mm x 86mm Mounting boxes 9047 surface. These popular markings are offered on a fast track service in red as standard. To order any of the markings listed below. Indicate the finish you require by adding suffix to List No. Two earth terminals are fitted. ie 4316/SC engraved ‘emergency circuit’ = 4316/SC/EC. sockets and fused connection units with red rockers are available to order. To order. Bronze (BZ). 45A DP SLIM LINE COOKER CONTROL UNIT BS 4177 & BS 1363 45A DP main switch and 13A switched socket outlet Faceplate marked ‘COOKER’ Dimensions Mounting boxes ● ● ● ● 4522/3BZ l PACK QTY 1 4522/3_ _ 146mm x 86mm 9054 surface. etc. Oyster Gold (YR). These are ideal for use in hospitals. and Highly Polished Chrome (HPC). ie 4522/3 Cooker switch in Bronze = 4522/3BZ. 37 . contact our Technical Services Department. SB628 flush galv. ie 4316/SC with red rockers = 4316/SC/RD. C A P I TA L M E TA L P L AT E 4837/3SC/ST 4832/3BZ/EF SUFFIX 4316/SC/RD For full specification details of finishes see Technical Data page 112. computer installations. SHAVER SUPPLY UNIT l BS EN 61558 PACK QTY 240V 50Hz input 115V 50Hz output 230V 50Hz 1 2411/_ _ } Dimensions Mounting boxes ● 86mm x 146mm 9053 surface. MARKING air conditioner 4832/3SC/EC 4832/BZ/HD AC MARKING SUFFIX MARKING SUFFIX heater HT security light SL bell transformer BE hob HB shower SH cooker hood HD humidity vent HV shower pump SP daytime boost DB intruder alarm IA storage heater ST dishwasher DW microwave MW towel rail TR emergency circuit EC night immersion NI tumble dryer TD extractor fan EF oven OV washing machine WM freezer FZ panel heater PH waste disposal WD fridge FR security alarm SA water cooler WC fridge freezer FF For price and delivery information on other markings not listed above. 2411/SC PRODUCT ENGRAVING SERVICE l A wide range of markings can be added to 13A fused connection units and double pole control switches. or SB631 dry lining Black or brown insert available made to order. or SB629 dry lining Same plate size as standard twin socket. add suffix to List No.All the following list numbers are available in Satin Chrome (SC). Separate double pole switching for both cooker and socket. RED ROCKERS For applications where essential supply systems are in use. add suffix to List No. Polished Stainless Steel (PSS) is available made to order. Large capacity tunnel terminals on live and neutral take up to 10mm2 cable. For Rockergrid switches with red rockers see Rockergrid section page 48. SB625 flush galv. 38 . DECORATIVE BRASS Crabtree’s Decorative Brass range is designed to complement its extensive ’Capital’ range. Polished brass Rope Edge Brass C A P I TA L D E C O R AT I V E B R A S S 39 . Also available in clam shell packaging for wholesale display. Polished and lacquered solid brass faceplates give a durable high quality finish. Indicate the finish you require by adding suffix to List No. or SB619 dry lining C A P I TA L D E C O R AT I V E B R A S S * Unshuttered version available for export only – Add suffix E to List No. ie 8075/PBE.All the following list numbers are available in Polished Brass (PB) and Rope Edge (RB) finishes. ie 4314 13A 1 gang switched socket in Rope Edge = 4314/RB. ie 4314/RB 13A 1 gang switched socket in Rope Edge with brown interior = 4314/3RBBN. For spare fuse links see page 6. Cord outlet suitable for flexible cord up to 10mm outside diameter. SB625 flush galv. Prefix list number with C. ie: C4314/RB. Add suffix BN to list no.Add suffix 9 to List No. Two earthing terminals are fitted to the unit. SB615 flush galv. 4316/DPB 4314/3PB 4316/3RBBN 2A. 13A FLUSH SOCKET OUTLETS l BS 1363 PACK QTY 1 gang SP switched 1 4314/_ _ 2 gang SP switched 1 4316/_ _ 1 gang SP switched fitted with neon indicator 1 4314/3_ _ 2 gang SP switched fitted with neon indicator 1 4316/3_ _ Dimensions 4314/PBBN 4316/RB PB 1 gang 86mm x 86mm RB 1 gang 94mm x 94mm 2 gang 146mm x 86mm 2 gang 154mm x 94mm Mounting boxes 1 gang 9221/BG surface. SB615 flush galv. or SB619 dry lining 2 gang 9223/BG surface. For full specification details of finishes see Technical Data page 112.Add suffix D to List No. Clam shell packaging format available. Products are also available with brown interiors. or SB619 dry lining 4832/PB 4837/3PB 4832/PB BN 4837/3RB All fused connection units: Fused on the line side with 13A fuse link ASTA certified and marked to BS 1362. 40 l PACK QTY . or SB629 dry lining Metal rocker versions are available to order . ie 4316/PB/9 Double pole versions are available to order . SB615 flush galv. ** Product available in white only 8075/PB 13A FLUSH FUSED CONNECTION UNITS BS 1363 DP switched 1 4832/_ _ DP switched with neon indicator 1 4832/3_ _ DP switched with cord outlet and neon indicator 1 4837/3_ _ Dimensions PB 86mm x 86mm RB 94mm x 94mm Mounting boxes 9221/BG surface. 15A FLUSH SOCKET OUTLETS l PACK QTY 2A 3 pin unswitched 1 8075/_ _* 15A 3 pin switched 1 2372/_ _** Dimensions PB 86mm x 86mm RB 94mm x 94mm Mounting boxes 9221/BG surface. SB615 flush galv. Add suffix BN to list no. or SB619 dry lining Two earthing terminals are fitted to the switches. Fully rated for fluorescent or inductive loads. or SB619 dry lining Two earthing terminals are fitted to the switches. 4012/3RB 50A DP CONTROL SWITCHES BS EN 60669-1 l PACK QTY DP switch 1 4512/_ _ DP switch with neon indicator 1 4512/3_ _ Dimensions Mounting boxes PB 86mm x 146mm 9040 surface.All the following list numbers are available in Polished Brass (PB) and Rope Edge (RB) finishes. 10AX PLATE SWITCHES l BS EN 60669-1 PACK QTY 1 gang 2 way 1 6170/_ _ 2 gang 2 way 1 6172/_ _ 3 gang 2 way 1 6173/_ _ 1 gang Intermediate 1 6175/_ _ 1 6096/_ _ 1 gang retractive (press) 6170/PBBN 6172/RB Dimensions Mounting boxes PB 86mm x 86mm RB 94mm x 94mm 9043 surface. 4011/3PB l BS EN 60669-1 PACK QTY DP switch with neon indicator Dimensions Mounting boxes 1 4012/3_ _ PB 86mm x 86mm RB 94mm x 94mm 9041 surface. (Except 6096. Available in Polished Brass only C A P I TA L D E C O R AT I V E B R A S S 32A DP CONTROL SWITCH 4512/3PBBN For full specification details of finishes see Technical Data page 112. 10A only) Retractive switch can be wired for normally open (N/O) or normally closed (N/C) circuits. Indicate the finish you require by adding suffix to List No. ie: C4011/3RB. For associated cable outlets see page 8. or SB619 dry lining Two way switches can be wired as one way. Prefix list number with C. SB655 flush galv. 6173/RBBN 20A DP CONTROL SWITCHES l BS EN 60669-1 PACK QTY 20A DP control switch 1 4011/_ _ 20A DP control switch with neon indicator 1 4011/3_ _ Dimensions Mounting boxes PB 86mm x 86mm RB 94mm x 94mm 9047 surface. Products are also available with brown interiors. ie 4011/3 Double pole switch in Rope Edge = 4011/3RB. Clam shell packaging format available. 41 . SB623 flush galv. SB625 flush galv. ie 4011/3 Double pole switch in Rope Edge with brown interior = 4011/3RBBN. Cord outlet suitable for flexible cord up to 10mm outside diameter. or SB629 dry lining BS EN 60947-3 rating 240V 50A category of duty AC22. SB615 flush galv. or SB632 dry lining Other options available. SB615 flush galv. SB628 flush galv. ie 2411 Shaver Supply Unit in Polished Brass = 2411/PB. SB625 flush galv. ie: C2411/PB. ie 2411 Shaver Supply Unit in Polished Brass with brown interior = 2411 /PBBN. Prefix list number with C. 2411/PB CO-AXIAL SOCKET OUTLETS BS 3041 WHERE APPLICABLE l PACK QTY 1 way direct connection 1 8265/_ _** 2 way direct connection 1 8266/_ _** 1 way isolated UHF. SB625 flush galv. VHF 1 8267/_ _** 2 way isolated UHF. Indicate the finish you require by adding suffix to List No. or SB631 dry lining Black or brown moulded insert available as made to order. Products marked ** are not available with black or brown interiors. or SB632 dry lining Other low voltage options available. 2000 1 6141/_ _ 2 gang 10A 2 way 1 6142/_ _ 1 gang 20A 2 way 1 6151/_ _ 1 gang 20A 2 way and Off 1 6125/_ _ 2 gang 20A 2 way 1 6152/_ _ Dimensions 6141/PB 6142/RB PACK QTY 1 gang 10A 2 way 1-2 gang PB 86mm x 86mm. or SB629 dry lining 1 gang 630W SB618 flush galv. or SB619 dry lining 3-4 gang 9223/BG surface. please enquire for details. or SB629 dry lining 1 gang 630W SB618 flush galv. DIMMER SWITCHES l C A P I TA L D E C O R AT I V E B R A S S PACK QTY 1250W/PB 2400W/RB 1 gang dimmer 250W 1 1250W/_ _ 1 gang dimmer 400W 1 1400W/_ _ 1 gang low voltage dimmer 400W 1 1400LV/_ _ 1 gang dimmer 630W 1 1630W/_ _ 2 gang dimmer 250W 1 2250W/_ _ 2 gang dimmer 400W 1 2400W/_ _ 3 gang dimmer 250W 1 3250W/_ _ 4 gang dimmer 250W 1 4250W/_ _ Dimensions 1-2 gang PB 86mm x 86mm. RB 94mm x 94mm Mounting boxes 1-2 gang 9221/BG surface.All the following list numbers are available in Polished Brass (PB) and Rope Edge (RB) finishes. 42 . RB 154mm x 94mm Mounting boxes 1-2 gang 9221/BG surface. SB655 flush galv. Clam shell packaging format available. VHF 1 8268/_ _** Dimensions PB 86mm x 86mm RB 94mm x 94mm Mounting boxes 9047 surface. For full specification details of finishes see Technical Data page 112. See pages 49 & 51. TOGGLE SWITCHES l BS EN 60669-1. SHAVER SUPPLY UNIT l BS EN 61558 PACK QTY 240V 50Hz input 115V 50Hz output 230V 50Hz 1 2411/_ _ } Dimensions Mounting boxes PB 86mm x 146mm RB 94mm x 154mm 9053 surface. Add suffix BN to list no. or SB619 dry lining 3-4 gang 9223/BG surface. or SB619 dry lining 8265/PB 8268/RB Isolated units only suitable on installations with earth bond. Products are also available with brown interiors. RB 94mm x 94mm 3-4 gang PB 146mm x 86mm. RB 154mm x 94mm When ordering Rockergrid plates. Products are also available with brown interiors. Add suffix BN to list no. the fixing ears should be removed or bent downwards at 90°. TELEPHONE SOCKET OUTLETS l PACK QTY Single master 1 8283/_ _ Single secondary 1 8284/_ _ Dimensions Mounting boxes 8283/PB PB 86mm x 86mm RB 94mm x 94mm 9221/BG surface. Prefix list number with C. SB615 flush galv. 2 gang 154mm x 94mm 6577/RB ROCKERGRID FLUSH PLATES l PACK QTY 1 6571/_ _ 2 gang Rockergrid plate 1 6572/_ _ 3 gang Rockergrid plate 1 6573/_ _ 4 gang Rockergrid plate 1 6574/_ _ Dimensions 1-2 gang PB 86mm x 86mm. ie 8283 telephone single master socket outlet in Rope Edge with brown interior = 283/RBBN. Clam shell packaging format available. please select the appropriate grid. Complete with earth terminal. ie 8283 telephone single master socket outlet in Rope Edge = 8283/RB. RB 94mm x 94mm 3-4 gang PB 146mm x 86mm. C A P I TA L D E C O R AT I V E B R A S S 1 gang Rockergrid plate For full specification details of finishes see Technical Data page 112.All the following list numbers are available in Polished Brass (PB) and Rope Edge (RB) finishes. ie: C8283/RB. 43 . 6572/RB fitted with Rockergrid switches GRIDS l PACK QTY 1 gang grid 20 6901 2 gang grid 20 6902 3 gang grid 10 6903 10 6904 4 gang grid Dimensions 6901 6902 1-2 gang 81mm x 58mm 3-4 gang 141mm x 58mm When required for surface mounting assemblies. Indicate the finish you require by adding suffix to List No. The Rockergrid plates and grids accept any of the range of Rockergrid switches. See page 48 & 49 for full product selection. 2 gang 146mm x 86mm RB 1 gang 94mm x 94mm. or SB619 dry lining 8284/RBBN BLANKING PLATES l BS 5733 WHERE APPLICABLE PACK QTY 1 gang 2 gang Dimensions 6575/PB 1 6575/_ _ 1 6577/_ _ PB 1 gang 86mm x 86mm. A unique key (suppied) is required to lock the Toggle Switch in place. 44 . Rockergrid provides the design versatility of a modular switch range whilst incorporating Capital styling and safety features which benefit the user and installer alike.MODULAR SYSTEM The New Crabtree Toggle Switch compliments the current Rockergrid range. ROCKERGRID MODULAR SYSTEM Polished Stainless Steel 45 .Rope Edge Brass Polished Brass Satin Chrome Highly Polished Chrome Bronze Oyster Gold White • Unique labyrinth switch design minimises visible arc flash and prevents front access to live parts. Birch Grey • Silver alloy contacts for longer life and low contact resistance. • Positive drive switch action prevents balancing between the ‘on’ and ‘off’ position and gives reliable indication of the contact position. ● When Flush mounting do not remove ‘ears’. ● ● Boxes. ● Single screw switch fixing. . Fingerproof shrouding around terminals.SELECTION TABLE l PLATES Gang 1 2 3 4 6 8 9 12 BIRCH GREY Engraved ‘Water Heater’ 6581/BG 6581/1BG 6582/BG 6582/1BG 6583/BG 6584/BG 6586/BG 6588/BG 6589/BG 6580/BG BRONZE Engraved ‘Water Heater’ 6561/BZ 6561/1BZ 6562/BZ 6562/1BZ 6563/BZ 6564/BZ 6566/BZ 6568/BZ 6569/BZ 6560/BZ SATIN CHROME Engraved ‘Water Heater’ 6561/SC 6561/1SC 6562/SC 6562/1SC 6563/SC 6564/SC 6566/SC 6568/SC 6569/SC 6560/SC OYSTER GOLD Engraved ‘Water Heater’ 6561/YR 6561/1YR 6562/YR 6562/1YR 6563/YR 6564/YR 6566/YR 6568/YR 6569/YR 6560/YR 5571 5572 5573 5574 5576 ROCKERGRID MODULAR SYSTEM SELECTION GUIDE Surface 46 Flush MOULDED WHITE WHITE METAL 6578/WH 6570/WH BRONZE Engraved ‘Water Heater’ 6571/BZ 6571/1BZ 6572/BZ 6572/1BZ 6573/BZ 6574/BZ 6576/BZ 6578/BZ 6579/BZ 6570/BZ SATIN CHROME Engraved ‘Water Heater’ 6571/SC 6571/1SC 6572/SC 6572/1SC 6573/SC 6574/SC 6576/SC 6578/SC 6579/SC 6570/SC OYSTER GOLD Engraved ‘Water Heater’ 6571/YR 6571/1YR 6572/YR 6572/1YR 6573/YR 6574/YR 6576/YR 6578/YR 6579/YR 6570/YR HIGHLY POLISHED CHROME 6571/HPC 6572/HPC 6573/HPC 6574/HPC 6576/HPC 6578/HPC 6579/HPC 6570/HPC POLISHED STAINLESS STEEL 6571/PSS 6572/PSS 6573/PSS 6574/PSS 6576/PSS 6578/PSS 6579/PSS 6570/PSS POLISHED BRASS 6571/PB 6572/PB 6573/PB 6574/PB 6576/PB 6578/PB 6579/PB 6570/PB ROPE EDGE BRASS 6571/RB 6572/RB 6573/RB 6574/RB 6901 6902 6903 6904 2 x 6903 2 x 6904 3 x 6903 3 x 6904 with knock-outs 9201/BG 9201/BG 9203/BG 9203/BG 9206/BG 9206/BG 9209/BG 9209/BG without knock-outs 9201/PBG 9201/PBG 9203/PBG 9203/PBG 9206/PBG 9206/PBG 9209/PBG 9209/PBG SB615 SB615 SB625 SB625 GRIDS Flush or surface BOXES Flush or surface Flush only ASSEMBLY 1 Install box and enter cables. 2 Remove ‘ears’ from grid for surface installations. grids & switches common to flush & surface installations. 3 Fix switches into grid. ROCKERGRID MODULAR SYSTEM SELECTION GUIDE 6560/18YR 1 SWITCHES 47 . ● ● Large capacity. high quality moulded & metal parts. Oyster Gold (YR). Bronze (BZ). 4460/9PBBN ACCESSORIES l Cord outlet 4435 13A fused connection unit 4436 6570/18YR 6570/24YR 6591/YR Neon indicator (Red) 4491 6570/18HPC 6570/24HPC 6591/HPC 6592/HPC Neon indicator (Green) 4493 6570/18PSS 6570/24PSS 6591/PSS 6592/PSS Neon indicator (Amber) 4494 6592/PB Socket outlet 2. ● ● Automatic grid alignment with horizontal adjustment. Polished Brass (PB). Diagrammatic marking on rear of switch. ● IP66 protected Rockergrid switch enclosures are available. ● Metal plate switch modules incorporate double insulation. see Weatherseal section page 60. 3 x 6906 4 x 6906 9209/18BG 9209/24BG Supplied fitted to architrave plate Switch modules: ● Tough impact-resistant thermoplastic moulded construction. and Highly Polished Chrome (HPC). 6 Fix face plate onto grid. ● Suitable for panel mounting and OEM applications. easy-to-wire terminals. Robust impact resistant construction. 5 Fix wired switch/grid assembly into box. 9209/18PBG 9209/24PBG 9341/GV 9342/GV 4 Connect wires to relevant switches & earth terminals. Architrave 18 6580/18BG 24 2 6580/24BG 6560/18BZ 6560/24BZ 6560/18SC 6560/24SC 6560/24YR 6570/18WH 6570/24WH 6591/WH 6592/WH 6570/18BZ 6570/24BZ 6591/BZ 6592/BZ 6570/18SC 6570/24SC 6591/SC 6592/SC ROCKER l MOULDED METAL 10AX 1 way 4430 4430/9_ _* 10AX 2 way 4530 4530/9_ _* 10AX Retractive 4489 4489/9_ _* 10AX Retractive marked with bell symbol 4490 4490/9_ _* 10AX Retractive 2 way and off 4553 4553/9_ _* 20A 1 way 4450 4450/9_ _* 20A 1 way key switch c / w key 4451 20A 2 way 4550 20A 2 way key switch c / w key 4551 20A 2 way and off 4552 4552/9_ _ 20A Intermediate 4535 4535/9_ _* 20A Double pole 4460 4460/9_ _* 20A Double pole marked ‘ON’ 4469 4469/9_ _* 20A Double pole key switch c / w key 4461 Switches are available in Brown (BN) and Black (BK) eg: 4460/BN.* Metal rocker finishes: Satin Chrome (SC).5–16A 4499† Blanking component 4492 Spare key 6940 (Metal) 6570/18PB 6570/24PB 6592/YR 6591/PB 4550/9_ _* Accessories are available in Brown (BN) and Black (BK) eg: 4436/BK † Available for export use only. 4550/9PBBN available as standard items.See page 51 10 4460/_ _ DP complete with key 10 4461 DP with key marked “Emergency Lighting Test” 10 4461/ELT DP marked ‘ON’ 10 4469 Intermediate 10 4535 2 way 10 4550 2 way complete with key 10 4551 2 way with key marked “Emergency Lighting Test” 10 4551/ELT 2 way and off 10 4552 Spare key 10 6940 ROCKERGRID MODULAR SYSTEM Available as made to order in Brown (BN) or Black (BK) eg: 4550/BN Fully rated for fluorescent and inductive loads (except List No. 48 4535/9_ _ 4535 .10AX SWITCHES – MOULDED ROCKER BS EN 60669-1 4430 4530 4490 1 way SP 10 4430 2 way SP 10 4530 Retractive 10 4489 Retractive – bell symbol 10 4490 Retractive 2 way and off 10 4553 Available as made to order in Brown (BN) or Black (BK) eg: 4530/BN Fully rated for fluorescent and inductive loads (except List No. For panel cut-out details see dimensions on page 124. 4430/RD 4460/BN 4460/RD 4535/BN 4535/9PBBN Red rockers 4430 4530 4450 4460 4550 4490 Add /RD to list number. OTHER SWITCH VARIATIONS l The following modules are available with brown or black mouldings to order. 4430 4491 4430/9_ _ 4450 4493 4450/9_ _ 4490 4550 4490/9_ _ Brown add /BN Black add /BK. Note 4530/9PBBN. 4460/9PBBN.4552). (except List No. complete with earthing terminal and cable clamp 10 4435 Fuse unit fitted with 13A ASTA certified fuse link 10 4436 Indicator – Red 10 4491 Blanking component 10 4492 Indicator – Green 10 4493 Indicator – Amber 10 4494 Socket outlet 2. 4553) 4530/BN 20A SWITCHES – MOULDED ROCKER BS EN 60669-1 4450 4460 4535 4550 4469 4552 4451 4551 4461 l PACK QTY 6940 l PACK QTY 1 way 10 4450 1 way complete with key 10 4451 DP 10 4460 Various markings .5–16A 10 4499* Available as made to order in Brown (BN) or Black (BK) * Not for use inside the UK where IEE Regulations (BS 7671) are applicable. ACCESSORIES – MOULDED 4435 4436 4491 4492 4494 4499 l BS 5733 WHERE APPLICABLE PACK QTY Dimmer module grid adaptor 10 4480 Cord outlet – 10mm diameter aperture.4553). 4490 Retractive switch can be wired for normally open (N/O) or normally closed (N/C) circuits. Available early 2004. Complete with earth terminal. 49 . 4430/9PB 4530/9PB 4490/9BZ 4490/9PB 20A SWITCHES – METAL PLATE ROCKER BS EN 60669-1 4469/9SC 4450/9SC 4460/9SC 4535/9SC 4550/9SC 4469/9BZ 4450/9BZ 4460/9BZ 4535/9BZ 4550/9BZ 4450/9PB 4460/9PB 4535/9PB 4550/9PB 1 way 10 4450/9_ _ DP 10 4460/9_ _ DP marked ’ON‘ 10 4469/9_ _ Intermediate 10 4535/9_ _ 2 way 10 4550/9_ _ Available as made to order in Brown (BN) or Black (BK) eg: 4460/9SCBK Fully rated for fluorescent and inductive loads. Bronze (BZ). Retractive switches can be wired for normally open (N/O) or normally closed (N/C) circuits. For cut-out Dimensions. see page 125. ROCKERGRID MODULAR SYSTEM 5550/HPC 5550/PB l PACK QTY TOGGLE SWITCH 5550/SC l PACK QTY For full specification details of finishes see Technical Data page 112. DIMMERS l PACK QTY 250W dimmer module 10 4425 400W dimmer module 10 4440 ● ● Dimmer modules come complete with grid adaptor (4480). Oyster Gold (YR) High Polished Chrome (HPC) and Polished Brass (PB) rockers. l BS EN 60669-1 5550/BZ PACK QTY 10AX 2 way Single Pole 5 5430/_ _ 20A 2 way Single Pole 5 5550/_ _ 20A 2 way and Off Single Pole 5 5552/_ _ One Fixing Key supplied per pack. 4440 GRIDS l 1 gang 20 6901 2 gang 20 6902 3 gang 10 6903 4 gang 10 6904 10 6906 6 gang Dimensions 6901 6902 1–2 gang 81mm x 58mm 3–4 gang 141mm x 58mm 6 gang 202mm x 58mm When required for surface mounting assemblies. eg 4430/9 with Bronze rocker = 4430/9BZ.All the following metal plate switches are available with Satin Chrome (SC). Indicate the finish you require by adding the suffix to List No. the fixing ears should be removed or bent inwards at 90°. 10AX SWITCHES – METAL PLATE ROCKER BS EN 60669-1 4430/9SC 4530/9SC 4430/9BZ 4530/9BZ 4490/9SC 1 way 10 4430/9_ _ Retractive 10 4489/9_ _ Retractive – bell symbol 10 4490/9_ _ 2 way 10 4530/9_ _ Available as made to order in Brown (BN) or Black (BK) eg: 4530/9PBBN Fully rated for fluorescent and inductive loads. SC for Satin Chrome finish. see dimensions on page 124. – BZ for Bronze finish. HPC for Highly Polished Chrome. 6568/SC 50 For full specification details of finishes see Technical Data page 112. SURFACE METAL PLATES l PACK QTY 6561/SC 6563/BZ 1 gang 20 6561/_ _ 1 gang faceplate engraved ‘water heater’ 20 6561/1_ _ 2 gang 20 6562/_ _ 2 gang faceplate engraved ‘water heater’ 20 6562/1_ _ 3 gang 10 6563/_ _ 4 gang 10 6564/_ _ 6 gang 1 6566/_ _ 8 gang 1 6568/_ _ 9 gang 1 6569/_ _ 12 gang 1 6560/_ _ 18 gang 1 6560/18_ _ 1 6560/24_ _ 24 gang Dimensions 1–2 gang 77mm x 77mm 9–12 gang 137mm x 197mm 3–4 gang 137mm x 77mm 18 gang 197mm x 257mm 6–8 gang 137mm x 137mm 24 gang 197mm x 257mm Add to List No. RB not available in 6-24 gang or architrave. For panel cut out detail. SC for Satin Chrome finish. PSS for Polished Stainless Steel finish. . PB for Polished Brass finish. HPC for High Polished Chrome finish. *Available in White Finish. YR for Oyster Gold finish. – BZ for Bronze finish.FLUSH MOULDED PLATES l PACK QTY 1 gang 20 5571 2 gang 20 5572 3 gang 10 5573 4 gang 10 5574 1 5576 1 gang 20 6571/_ _ 1 gang faceplate engraved ‘water heater’ 20 6571/1_ _ 2 gang 20 6572/_ _ 2 gang faceplate engraved ‘water heater’ 20 6572/1_ _ 3 gang 10 6573/_ _ 4 gang 10 6574/_ _ 6 gang 1 6576/_ _ 8 gang 1 6578/_ _* 9 gang 1 6579/_ _ 12 gang 1 6570/_ _* 18 gang 1 6570/18_ _* 24 gang 1 6570/24_ _* 1 gang architrave complete with grid 10 6591/_ _* 2 gang architrave complete with grid 10 6592/_ _* 6 gang 5571 5574 Dimensions 1–2 gang 86mm x 86mm 3–4 gang 146mm x 86mm 6 gang 147mm x 147mm FLUSH METAL PLATES ROCKERGRID MODULAR SYSTEM Dimensions 6592/SC 6570/24BZ l 1–2 gang 86mm x 86mm 1–2 gang RB 94mm x 94mm 3–4 gang 146mm x 86mm 3–4 gang RB 154mm x 94mm 6–8 gang 147mm x 147mm 9–12 gang 147mm x 207mm 18 gang 207mm x 267mm 24 gang 207mm x 267mm 1 gang architrave 35mm x 86mm 2 gang architrave 35mm x 146mm Add to List No. PB for Polished Brass. YR for Oyster Gold finish. RB for Rope Edge Brass finish. Add WH to List No. Spare earth terminal (List No. example 9201/PBG 20A DOUBLE POLE SWITCH MARKING “boiler” “dishwasher” “fridge” “fridge freezer” “heating system” “tumble dryer” “washer dryer” “water heater” 4460/HT 4460/WD 4460/EF 4460/WM 4460/HB 4460/BO 4460/DW 4460/FR 4460/FF 4460/HT 4460/TD 4460/WDR 4460/WA “cooker hood” “extractor fan” “freezer” “hob” “microwave” “waste disposal” “washing machine” l 4460/HD 4460/EF 4460/FZ 4460/HB 4460/MW 4460/WD 4460/WM • Can be used with 13A fuse units to build bespoke kitchen/utility room control panel. For fully assembled units.TOGGLE SWITCH PLATES l PACK QTY 1 gang toggle switch plate 10 6551/_ _ 2 gang toggle switch plate 10 6552/_ _ 3 gang toggle switch plate 10 6553/_ _ 4 gang toggle switch plate 10 6554/_ _ Dimensions 6551/SC 6552/BZ 1–2 gang 86mm x 86mm. see dimensions on page 124. SURFACE METALCLAD PLATES l PACK QTY 6581/BG 6580/BG 1 gang 20 6581/BG 1 gang faceplate engraved ‘water heater’ 20 6581/1BG 2 gang 20 6582/BG 2 gang faceplate engraved ‘water heater’ 20 6582/1BG 3 gang 10 6583/BG 4 gang 10 6584/BG 6 gang 1 6586/BG 8 gang 1 6588/BG 9 gang 1 6589/BG 12 gang 1 6580/BG 18 gang 1 6580/18BG 24 gang 1 6580/24BG Dimensions 1–2 gang 77mm x 77mm 3–4 gang 137mm x 77mm 6–8 gang 137mm x 137mm BOXES l 3 and 4 gang surface or flush 5 9203/BG* 6 and 8 gang surface or flush 1 9206/BG* 9 and 12 gang surface or flush 1 9209/BG* 18 gang surface or flush 1 9209/18BG* 24 gang surface or flush 1 9209/24BG* 1 gang architrave flush only 10 9341/GV 2 gang architrave flush only 10 9342/GV Dimensions 9201/BG 73mm x 73mm x 40mm 9203/BG 133mm x 73mm x 40mm 9206/BG 133mm x 133mm x 40mm 9209/BG 133mm x 194mm x 40mm 9209/BG PACK QTY 10 9201/BG* 9209/18BG 194mm x 254mm x 56mm 9209/24BG 194mm x 254mm x 56mm 9341/GV 29mm x 72mm x 36mm 9342/GV 29mm x 133mm x 36mm 16mm knock-outs in 1 and 2 gang box and architrave boxes. For full specification details of finishes see Technical Data page 112. For cut-out Dimensions. See page 125. SC for Satin Chrome finish.6989) see page 69. see page 35 or 42. PB for Polished Brass. Note: BG boxes fitted with earth terminal. * For boxes less knockouts list no. 3-4 gang 146mm x 86mm Add to List No. YR for Oyster Gold finish. 51 . ROCKERGRID MODULAR SYSTEM 1 and 2 gang surface or flush 9201/BG 9–12 gang 137mm x 197mm 18 gang 197mm x 257mm 24 gang 197mm x 257mm All of the above are supplied in pack quantities of 10. HPC for Highly Polished Chrome. 20mm and 25mm knock-outs in 3–24 gang boxes. – BZ for Bronze finish. For panel cut out detail. commerce and the home. • Production line tested for quality of gloss finish and uniform coverage of coating. discolouration and corrosion. • Finishing process is highly automated and controlled to ensure a consistent level of performance.METALCLAD • Tough durable finish which is resistant to premature ageing. 52 . In tough conditions the sturdily built Capital metalclad range is ideal for use in industry. eg Double pole 4216/BG = 4216/DBG. 53 . 13A UNSWITCHED SOCKET OUTLETS BS 1363 l PACK QTY 1 gang unswitched 10 9685/BG 2 gang unswitched 5 9687/BG Dimensions 1 gang 82mm x 82mm x 44mm 2 gang 142mm x 82mm x 44mm For sockets with plain boxes – Add suffix P to List No. Fused on the line side with a 13A fuse link ASTA certified and marked to BS 1362. eg 4216/BG with plain box = 4216/PBG. eg 4216/BG with plain box = 4216/PBG. For spare fuse links see page 6. Double pole available to order – Add suffix D to List No. Cord outlets suitable for flexible cord up to 10mm outside diameter. eg 4842/BG with plain box = 4842/PBG. Two earthing terminals are fitted to the unit. 4842/3BG 4847/3BG C A P I TA L M E TA L C L A D 4841/BG l PACK QTY For full specification details of finishes see Technical Data page 112. 9685/BG 9687/BG 13A FUSED CONNECTION UNITS BS 5733 WHERE APPLICABLE 4846/BG Unswitched 10 4841/BG Unswitched with neon indicator 10 4841/3BG DP switched 10 4842/BG DP switched with neon indicator 10 4842/3BG Unswitched with cord outlet 10 4846/BG DP switched with cord outlet 10 4847/BG DP switched with cord outlet and neon indicator 10 4847/3BG Dimensions 82mm x 82mm x 44mm For fused connection units with plain boxes – Add suffix P to List No.13A SWITCHED SOCKET OUTLETS BS 1363 1 gang SP 10 4214/BG 2 gang SP 5 4216/BG 1 gang SP with neon indicator 10 4214/3BG 2 gang SP with neon indicator 5 4216/3BG Dimensions 4214/BG 4216/3BG 4214/3BG 4216/BG l PACK QTY 1 gang 82mm x 82mm x 44mm 2 gang 142mm x 82mm x 44mm For sockets with plain boxes – Add suffix P to List No. All available with two earth terminals to enable installation to comply with section 607 (wiring regulations) Add suffix /TE to List No. 4512/BG 4512/3BG For full specification details of finishes see Technical Data page 112. For switches with plain boxes add suffix P to List No. 15A SWITCHED SOCKET OUTLETS BS 546 5A shuttered SP 15A shuttered SP Dimensions l PACK QTY 10 2240/BG 10 2272/BG 82mm x 82mm x 44mm For boxes less knockouts see page 68. 54 4021/3BG 4512/3BG . ie 4020/3BG with plain box = 4020/3PBG. 4426/A03BG 5A.13A SAFETYSOCKET WITH RCD PROTECTION BS 7288 1 gang switched with neon indicator 10mA tripping current flush mounting 1 gang switched with neon indicator 30mA tripping current flush mounting 2 gang switched with neon indicator 10mA tripping current flush mounting 2 gang switched with neon indicator 30mA tripping current flush mounting 1 gang switched with neon indicator 10mA tripping current surface mounting 1 gang switched with neon indicator 30mA tripping current surface mounting 2 gang switched with neon indicator 10mA tripping current surface mounting 2 gang switched with neon indicator 30mA tripping current surface mounting 4414/A01BG l PACK QTY 1 4414/A01BG 1 4414/A03BG 1 4416/A01BG 1 4416/A03BG 1 4424/A01BG 1 4424/A03BG 1 4426/A01BG 1 4426/A03BG Dimensions Flush –146mm x 86mm Surface –142mm x 82mm x 44mm Mounting boxes 4414 & 4416 series 9223/BG surface. 2240/BG 2272/BG 10AX SWITCHES l BS 3676 10AX 1 gang 2 way PACK QTY 10 4581/BG 10AX 2 gang 2 way 10AX 3 gang 3 way Dimensions 4581/BG 10 4583/BG 4583/BG l BS 3676 DP Switch with neon indicator C A P I TA L M E TA L C L A D 4582/BG 82mm x 82mm x 44mm 20A DP CONTROL SWITCHES PACK QTY 10 4020/3BG DP Switch with neon indicator and cord outlet Dimensions 4020/3BG 10 4021/3BG 10 82mm x 82mm x 44mm Cord outlet suitable for flexible cord up to 10mm outside diameter. For further information see page 102. Surface box fitted with earth terminal.SB665 flush galv or SB629 dry lining For boxes less knockouts see page 68. 50A DP CONTROL SWITCHES l BS 3676 DP Switch PACK QTY 10 4512/BG DP Switch with neon indicator Dimensions 10 142mm x 82mm x 51mm BS EN 60947-3 rating 240V 50A category of duty AC22. 25A (12kW/16 HP max). 32A 415V. These popular markings are offered on a fast track service in red as standard.32A TP & N CONTROL SWITCHES BS 3676 TYPE TESTED TO BS EN 60947-3 l PACK QTY With neon indicator Unit accommodates up to 6mm2 cable 1 4513/BG With neon indicator Unit accommodates up to16mm2 cable 1 4514/BG Dimensions 4513/BG 142mm x 82mm x 51mm 4514/BG 173mm x 122mm x 74mm Terminal capacity 16mm2 on all switches. computer installations. add suffix to List No. add suffix to List No. etc. BS EN60947-3 PACK QTY 6AX three pole isolating switch 10 4587/BG Provides local isolation of fans with or without timers whilst the rest of the circuit remains live. See pages 9 & 36 for further details. ie 4216/BG engraved ‘emergency circuit’ = 4216/BGEC. 240V only. Dimensions 82mm x 82mm x 44mm For full details of compliance with BS EN 60947-3 see Technical Data page 107. 4513/BG 6AX TP CONTROL SWITCHES l BS EN 60669-1. sockets and fused connection units with red rockers are available to order. 55 . 415V. contact our Technical Services Department. Enables repair or routine maintenance of fans. Utilisation category to BS EN 60947-3: AC 22. 4842/BGEF 4842/BGWA MARKING SUFFIX MARKING SUFFIX MARKING SUFFIX air conditioner AC heater HT security light SL bell transformer BE hob HB shower SH cooker hood HD humidity vent HV shower pump SP daytime boost DB intruder alarm A storage heater ST dishwasher DW microwave MW towel rail TR TD night immersion N tumble dryer extractor fan EF oven OV washing machine WM freezer FZ panel heater PH waste disposal WD fridge FR security alarm SA water cooler WC fridge freezer FF water heater WA For price and delivery information on other markings not listed above. ie 4216/BG with red rockers = 4216/BG/RD. BLANKING PLATES FOR SURFACE REPLACEMENT BOXES l PART NO 3899BG PACK QTY 2 gang blank plate for list no 9214/BG 5 3809BG 1 gang blank plate for list no 9211/BG 10 3899BG C A P I TA L M E TA L C L A D emergency circuit EC 3809BG For full specification details of finishes see Technical Data page 112. RED ROCKERS For applications where essential supply systems are in use. 4513/BG 4514/BG PRODUCT ENGRAVING SERVICE l A wide range of markings can be added to 13A fused connection units and double pole control switches. AC 23. To order. To order any of the markings listed below. 4216/BG/RD For Rockergrid switches with red rockers see Rockergrid section page 48. These are ideal for use in hospitals. WATER & DUST PROTECTED 56 . 57 . Weatherseal is ideal for all environments. Most items can be purchased complete with shallow enclosure. or in modular form for fitting separately in one to six gang enclosures in any combination.Crabtree’s new IP56 socket outlet is available as switched or unswitched and retains IP56 rating whilst in use. W E AT H E R S E A L WAT E R & D U S T P R O T E C T E D Water and dust protected to IP66. Crabtree’s new IP66 20AX surface switch retains it’s full rating whilst in use. however seek advice before installing in environments where chemicals or harsh cleaners are likely to be used.RCD terminals accept 25mm2 cable.20A SURFACE SWITCHES l IP66 PACK QTY 1 gang 2 way 2 gang 2 way Dimensions 1 9664 1 9668 1 & 2 gang 103mm x 82mm x 68mm Supplied as ready assembled units. 9664 9668 13A SURFACE SOCKET l BS 1363-2 IP56 PACK QTY Single unswitched socket 1 9660 Single switched socket 1 9660/S Twin unswitched socket (available 2004) 1 9660/2 Dimensions 1 gang 103mm x 82mm x 80mm 1 gang switched 162mm x 82mm x 80mm 2 gang 162mm x 120mm x 80mm W E AT H E R S E A L WAT E R & D U S T P R O T E C T E D The socket outlets retain their IP56 rating when used with any standard 13A plug. RCD terminals accept 25mm2 cable. see page 103. Type A available. Supplied as ready assembled units on appropriate enclosures. RCD is Type AC operation. RCD is Type AC operation. see page 103. 9660 9660/S Supplied as ready assembled units. 9571 9572 RCD PROTECTED 16A 240V SOCKET SOCKET BS 4343 RCD BS EN 61008 40A 30mA RCD protecting 16A 2P + E 240V splashproof socket l PACK QTY 1 9579 Supplied as ready assembled units on appropriate enclosures. For IP ratings see Technical details on Page 106. Common to 110V and 240V BS 4343 splashproof sockets IP44 protection is maintained when plug is inserted. IP66 is maintained when cover flap is closed. Will give BS 5490 IP66 protection when 9599 plug is used. Type A available. 58 l . 9579 Polycarbonate is a highly durable material which is ideal for use in most environments. RCD PROTECTED 13A SOCKETS SOCKET BS 1363 RCD BS EN 61008 PACK QTY 40A 30mA RCD protecting one 13A socket 1 9571 40A 30mA RCD protecting two 13A sockets 1 9572 Dimensions 3 gang size 296mm x 102mm x 104mm 4 gang size 199mm x 199mm x 104mm Sockets incorporate transparent flap which automatically snaps shut when the plug is withdrawn. The individual switches and sockets listed on this page are supplied as ready assembled units on shallow enclosures. The switched socket combination unit is pre-wired and supplied as ready assembled units on appropriate enclosures. 10A SURFACE SWITCHES l BS 3676 BS 5490 IP66 PACK QTY 1 gang 1 way 2 gang 1 way Dimensions 9561 4 9561 2 9562 1 gang 101mm x 101mm x 76mm 2 gang 197mm x 101mm x 76mm Padlock off facility provided. See page 100 for suitable padlock. Terminals accepted 2.5mm2 cable. rear view 13A PLUGS, SURFACE SOCKETS & COMBINATION UNITS l 9599 PACK QTY Single socket outlet 4 9565 Switched socket combination 2 9567 Sleeved plug 9 9599 Dimensions MODULAR SELECTION Sockets incorporate transparent flap which automatically snaps shut when the plug is withdrawn. Terminals accept maximum 10mm2 cable. Will give BS 5490 IP66 protection when 9599 is used in combination with either 9565, 9565/L, 9567 or 9567/L. Plug ASTA approved by reference number 176. 9567 l The popular items listed on the page opposite and above are in ready-assembled form. These can also be built up from separate modules to allow greater stock flexibility, whilst additional separate sale switch, socket and cover modules with enclosures up to 6 gang size enable the installer to provide high IP-rated combinations to suit individual applications. 9567 or 9567/L + 9562/ES 9566/E + 9569/L + 9561/2L + 9567/L + 9570/2 + 224/030 Multi-gang enclosures enable any combination The table below lists the modular equivalents to the popular items supplied as ready assembled units. READY-ASSEMBLED UNITS MODULAR EQUIVALENT SELECTION DESCRIPTION LIST No COVER MODULE(S) ENCLOSURE RCD 10A switch – 1 gang 1 way 9561 9561/1L 9561/ES – 10A switch – 2 gang 1 way 9562 9561/1L x 2 9562/ES – 13A single socket outlet 9565 9565/L 9561/ES – 13A switched socket 9567 9567/L 9562/ES – 13A single socket with 40A 30mA RCD 9571 9570/2 + 9565/L 9563/E 224/030 13A twin socket with 40A 30mA RCD 9572 9570/2 x 1 + 9565L x 2 9564/E 224/030 16A 2P + E 240V socket – BS 4343 9579 9570/2 + 9569/L 9563/E 224/030 The table below lists module selection details for some additional popular combinations. DESCRIPTION COVER MODULE(S) ENCLOSURE RCD 13A twin socket outlet with single switch 9565/L x 2 + 9561/DL 9563/E – 13A twin-switched socket outlet 9567/L x 2 9564/E – 13A single-switched socket with 40A 30mA RCD 9570/2 x 1 + 9567/L 9564/E 224/030 W E AT H E R S E A L WAT E R & D U S T P R O T E C T E D 9565 1 gang size 101mm x 101mm x 76mm 2 gang size 197mm x 101mm x 76mm 59 SOCKET MODULES l BS 4343 9569/L 9591/L PACK QTY 16A 2P + E 240V splashproof socket 4 9569/L 16A 2P + E 110V splashproof socket 4 9591/L 16A 3P + E 415V splashproof socket 4 9592/L 16A 3PN + E 415V splashproof socket 4 9593/L Should be assembled in deep enclosures. IP44 protection is maintained when plug is inserted, on 110V and 240V sockets. IP66 is maintained when plug is inserted, on 415V sockets. 9593/L SWITCH MODULES l PACK QTY 9573/L 9561/2L 9573/RL 10A 1 way switch 4 9561/1L 10A 2 way switch 4 9561/2L 20A DP switch 4 9561/DL 32A TP switch 4 9573/L 32A TP switch – yellow/red 4 9573/RL Can be assembled in shallow enclosures. 13A SOCKET MODULES l W E AT H E R S E A L WAT E R & D U S T P R O T E C T E D PACK QTY 13A single unswitched socket 8 9565/L 13A switch/socket combination 2 9567/L Can be assembled in shallow enclosures. 9565/L 9567/L ROCKERGRID COVER MODULES 1 gang 4 9581/RG 2 gang 4 9582/RG ● ● ● ● 9581/RG 9582/RG Suitable for any Rockergrid module. Rockergrid modules fix directly into moulded-in grid with single screw fixing. Enables a wide range of switch variations in IP66 rated enclosures. Can be used to provide 2 gang switching option where space is insufficient for standard Weatherseal module. The selection table below lists some of the popular IP66 combinations which can be assembled from the Weatherseal and Rockergrid ranges. MODULE SELECTION l ROCKERGRID module(s) WEATHERSEAL cover module WEATHERSEAL enclosure 10AX 2 gang 1 way switch – single module size 4430 x 2 9582/RG 9561/ES 10AX retractive switch 4489 9581/RG 9561/ES 13A switched FCU 4460 + 4436 9582/RG 9561/ES 13A unswitched FCU + neon 4436 + 4494 9582/RG 9561/ES 20A intermediate switch 4535 9581/RG 9561/ES 20A DP switch + neon 4460 + 4494 9582/RG 9561/ES 20A DP key switch 4461 9581/RG 9561/ES 20A 2 gang 1 way switch – single module size 4450 x 2 9582/RG 9561/ES DESCRIPTION Rear view See page 48 for full range of Rockergrid switches. 60 l PACK QTY RCD COVER MODULE l PACK QTY 2 gang RCD cover with neon assembly and RCD mounting cradle 2 9570/2 Should be assembled in deep enclosures. ● 9570/2 Suitable for any 2 module RCD from the Lifestar range – see page 103. RCD mounting cradle shown in deep enclosure BLANK COVER MODULES l PACK QTY 1 gang blank cover 8 9561/L 2 gang blank cover 4 9562/L 3 gang blank cover 3 9563/L 9561/L l PACK QTY 9561/E 9562/ES 1 gang 4 9561/E 1 gang shallow 8 9561/ES 2 gang 2 9562/E 2 gang shallow 4 9562/ES 3 gang 3 9563/E 4 gang 1 9564/E 6 gang 1 9566/E Dimensions (mm) H 1 gang enclosure 103 1 gang shallow enclosure 101 2 gang enclosure 198 2 gang shallow enclosure 197 x x x x W 102 101 102 101 x x x x D 63 40 63 40 H W 3 gang enclosure 296 x 102 x 4 gang enclosure 199 x 199 x 6 gang enclosure 296 x 199 x SOCKET REAR SIDE CONDUIT KNOCK-OUTS ENTRIES 9561/E 1x32/25 1x25, 1x32 1 1 – – 9561, 9565 9561/ES 1x25/20 2x25 – 1 – – 9562/E† 1x25, 1x32 1x25, 1x32 1 1 – 1 9562, 9567 9562/ES 2x25/20 2x25 – 1 – 1 9563/E* 2x25, 1x32 1x25, 1x32 1 1 – 2 9564/E* 2x25 1x32, 1x40 2x25, 4x32 1 1 2 2 9566/E* 2x25 2x32, 2x40 2x25, 4x32 1 1 4 3 D 63 63 63 32/25 25/20 REDUCER REDUCER DIVIDER BRIDGE * Also supplied with 1 neutral & 1 earth connector. † Also supplied with 1 earth connector. 9566/E To maintain IP66 rating, cover all fixing screws with caps provided. Seal bridge/divider slots with suitable silicon sealant – Dow Corning RTV-732. Check all conduit entry points are tight before use. Threaded conduit entries can be fitted to all popular metal and moulded metric conduit using a variety of proprietory adaptors (less locking ring), reducers, and adhesive where appropriate: eg for fitting 20mm moulded conduit to 9567 use Marshall-Tufflex MA8 adaptor (less locking ring), MR2 reducer and MSC2 sealing cement. Polycarbonate is a highly durable material which is ideal for use in most nvironments, however seek advice before installing in environments where chemicals or harsh cleaners are likely to be used. W E AT H E R S E A L WAT E R & D U S T P R O T E C T E D ENCLOSURES 61 are available to suit many applications. Most Capital Products can also be supplied in brown as standard – ideal for brassware manufacturers. which complement the extensive Capital. 62 . range.The Capital range of Switched Sockets and Fused Control Units are available with metal capped rockers.INTERIORS & PANEL MOUNTING Interiors and panel mounting products. are also required. When specifying items with provision for neon indicators a lens. Two earth terminals also available where compliance with section 607 (wiring regs) is required . Part No.3713.5mm thickness and can be incorporated into a minimum overall internal depth of only 22. are also required.5mm.add suffix /TE to list No. Part No. Part No. 13A SAFETYSOCKET WITH RCD PROTECTION BS 7288 4416/A103 l PACK QTY 1 gang switched with neon indicator 10mA tripping current 1 4414/A101 1 gang switched with neon indicator 30mA tripping current 1 4414/A103 2 gang switched with neon indicator 10mA tripping current 1 4416/A101 2 gang switched with neon indicator 30mA tripping current 1 4416/A103 See page 102 for further information. eg 4314/1 switched in Brown = 4314/1DBN Two earth terminals also available where compliance with section 607 (wiring regs) is required .add suffix /TE to list No. 63 . Part No. eg 4316/1/TE When specifying items with provision for neon indicators a lens.3713. eg 4416/A103/TE C A P I TA L I N T E R I O R S & PA N E L M O U N T I N G 8255/1 l For panel cut-out details see page 123. 124 & 125.3711 and neon bulb.3711 and neon bulb. Two earth terminals also available where compliance with section 607 (wiring regs) is required . Double pole switching also available to order – Add suffix D to List No. 13A UNSWITCHED SOCKET OUTLETS l 1 gang unswitched 10 8255/1 2 gang unswitched 5 8257/1 1 gang round socket with side entry terminals and north/south fixings 10 7259 The 7259 panel mounting socket is suitable for use in any panel or trunking material up to 2.13A SWITCHED SOCKET OUTLETS 4314/1BN 4316/1 l 1 gang SP PACK QTY 10 4314/1 2 gang SP 5 4316/1 1 gang SP with provision for neon indicator 10 4314/13 2 gang SP with provision for neon indicator 5 4316/13 Brown mouldings also available – Add suffix BN to List No. eg 8257/1/TE 8257/1 FUSED CONNECTION UNITS 4831/1 4832/1BN l 13A unswitched 10 4831/1 13A DP switched 10 4832/1 13A DP switched with provision for neon indicator 10 4832/13 13A unswitched with cord outlet 10 4836/1 13A DP switched with cord outlet 10 4837/1 13A DP switched with cord outlet and provision for neon indicator 10 4837/13 Brown interiors also available – Add suffix BN to List No.add suffix /TE to list No. add suffix /TE to list No. 15A ROUND PIN SOCKET OUTLETS 5A shuttered SP 10 2240/1 15A shuttered SP 10 2272/1 2A 3 pin unswitched shuttered 10 8075/1* * Brown mouldings also available – Add suffix BN to List No.3713. are also required. 2272/1 2240/1 45A DP ‘SLIMLINE’ COOKER CONTROL UNITS l PACK QTY 45A DP main switch and 13A switch socket outlet 5 4522/1 45A DP main switch and 13A switch socket outlet with neon indicators 5 4522/13 Brown interiors also available – Add suffix BN to List No. Finishes available are: Satin Chrome (SC). Bronze (BZ).3713. eg 4314/1 switched in Brown = 4314/19DBN/SC Two earth terminals also available where compliance with section 607 (wiring regs) is required . eg 4316/1/TE When specifying items with provision for neon indicators a lens.METAL CAPPED ROCKERS 13A SWITCHED SOCKET OUTLETS 4314/19/_ _ 2 gang SP 5 4316/19/_ _ 1 gang SP with provision for neon indicator 10 4314/139/_ _ 2 gang SP with provision for neon indicator 5 4316/139/_ _ 1 gang SP 4314/19/SC 4316/19BN/PB l PACK QTY 10 Brown mouldings also available – Add suffix BN to List No.3711 and neon bulb.3711 and neon bulb. are also required. Part No. Part No. 64 l PACK QTY . Part No. Oyster Gold (YR) & Polished Brass (PB) 2A. Finishes available are: Satin Chrome (SC). are also required. 5A. Oyster Gold (YR) & Polished Brass (PB) METAL CAPPED ROCKERS FUSED CONNECTION UNITS l C A P I TA L I N T E R I O R S & PA N E L M O U N T I N G PACK QTY 4832/19/SC 4832/19BN/PB 13A DP switched 10 4832/19/_ _ 13A DP switched with provision for neon indicator 10 4832/139/_ _ 13A DP switched with cord outlet 10 4837/19/_ _ 13A DP switched with cord outlet and provision for neon indicator 10 4837/139/_ _ Brown interiors also available – Add suffix BN to List No. Bronze (BZ). When specifying units with neon indicators lenses. Part No. Part Nos.3467 & 3711 and a neon bulb. 124 & 125.3713. 4522/1 For panel cut-out details see page 123. Double pole switching also available to order – Add suffix D to List No. When specifying items with provision for neon indicators a lens. Part No. 3711 and neon bulb. When specifying items with provision for neon indicators a lens. Grid fitted with earth terminal.124 & 125. 4011/1BN 50A DP SWITCHES l 50A DP 10 4512/1 50A DP with neon indicator 10 4512/13 Brown interiors also available – Add suffix BN to List No.3713.2471. 20A/32A DP SWITCHES l PACK QTY 20A DP 4011/1 10 4011/1 20A DP with provision for neon indicator 10 4011/13 32A DP 10 4012/1 32A DP with provision for neon indicator 10 4012/13 Interiors with Brown rockers available – Add suffix BN to List No. 8283/1 8284/1BN C A P I TA L I N T E R I O R S & PA N E L M O U N T I N G PACK QTY For panel cut-out details see pages 123. 2471 4512/13BN CO-AXIAL SOCKET OUTLETS l PACK QTY 1 way direct connection 1 8265/1 2 way direct connection 1 8266/1 1 way isolated VHF. Supplied with loose earth terminal. 8265/1 8266/1 TELEPHONE OUTLETS l PACK QTY Master 10 8283/1 Secondary 10 8284/1 Brown interiors also available – Add suffix BN to List No. 65 . Part No. When specifying the above items a mounting grid. are also required. Part No. UHF 1 8268/1 Isolated units only suitable on installations with earth bond. Part No.10AX SWITCHES l PACK QTY 6170/1 6173/1BN 1 gang retractive marked ‘press’ 10 6096/1 1 gang 2 way 10 6170/1 2 gang 2 way 10 6172/1 3 gang 2 way 10 6173/1 1 gang intermediate 10 6175/1 Interiors with Brown rockers available – Add suffix BN to List No. is also required. UHF 1 8267/1 2 way isolated VHF. INSTALLATION BOXES & SERVICE ITEMS The comprehensive range of white moulded patresses offers a facility to surface mount Capital wiring accessories 66 . Corinthian and Dimmer single gang size switches 9043 9048/1 9043 Dimensions 87mm x 87mm x 20mm 29mm deep Dual box for two single gang size accessories Fixed dividing barrier with knockouts 5 9044* 10 9047 5 9048* 5 9048/1* Dimensions 174mm x 87mm x 29mm For single gang size moulded accessories Dimensions 87mm x 87mm x 29mm For double gang size moulded accessories Dimensions 147mm x 87mm x 29mm With earth terminal For Capital 4 to 6 gang switches Dimensions 147mm x 87mm x 29mm 32mm deep Multipurpose box for single gang size accessories 5 9040 9053 9049* Dimensions 88mm x 165mm x 32mm Multipurpose box for double gang size accessories 2 9050* Dimensions 148mm x 165mm x 32mm 1 9052* 5 9053* 5 9054* 5 9406 Dimensions 169mm x 115mm x 45mm 49mm deep For shaver supply unit Will accept 25mm x 16mm mini-trunking 9052 Dimensions 87mm x 147mm x 49mm 45mm deep For slimline cooker control units Will accept 25mm x 16mm mini-trunking Fitted with cable clamp Dimensions 89mm x 147mm x 45mm 20mm deep 2 gang Surface conversion patresses Converts 1 gang flush box to 2 gang surface Dimensions 147mm x 87mm x 20mm * Can be secured to flush mounting steel boxes having 60.SURFACE MOULDED BOXES FOR CAPITAL WIRING ACCESSORIES BS 5733 l PACK QTY 20mm deep For Capital single gang moulded architrave 10 switches.3mm accessory fitting centres I N S TA L L AT I O N B O X E S 45mm deep For 45A cooker control units Fitted with cable clamp 9406 67 . will accept 16mm x 16mm mini-trunking 4006 Dimensions 33mm x 147mm x 20mm 4005 34mm deep For 50A Capital switches and Rockergrid 3 and 4 gang moulded assemblies Fitted with cable clamp 4006 5 9040* 10 9041 Dimensions 87mm x 147mm x 34mm 44mm deep For 15A socket outlets. 32A DP switches and Rockergrid 1 and 2 gang moulded assemblies Dimensions 87mm x 87mm x 44mm 20mm deep With earth terminal 10 For 10AX Capital moulded and metalplate. will accept 16mm x 16mm mini-trunking 4005 Dimensions 33mm x 87mm x 20mm For Capital double gang moulded architrave 10 switches. REPLACEMENT STEEL BOXES FOR CAPITAL SURFACE WIRING ACCESSORIES BS 5733 9211/BG 9214/BG l PACK QTY 43mm deep 20mm knockouts 10 Replacement box for 5. . Dividing fillets and alternative conduit entries available to order. Bases fitted with 1 x 20mm conduit clearance hole (25mm on double-sided).1250 on page 69. 13 and 15A single gang size surface accessories 9211/BG As above less knockouts 10 9211/PBG 43mm deep 20mm knockouts Replacement box for 13A gang size surface accessories 5 9214/BG As above less knockouts 5 9214/PBG Dimensions 78mm x 78mm x 43mm Dimensions 138mm x 78mm x 43mm 43mm deep 20mm knockouts 1 Replacement box for 4513 series of 32A TP & N switches Fitted with earth terminals and grid mounting pillars 9215/BG* Dimensions 78mm x 138mm x 43mm 65mm deep 20mm knockouts 1 Replacement box for 4514 series of 32A TP & N switches Fitted with 2 earth terminals and grid mounting pillars 9224/BG* Dimensions 118mm x 168mm x 65mm * Boxes less knockouts available to order 9215/BG 9224/BG SURFACE STEEL BOXES FOR CAPITAL FLUSH WIRING ACCESSORIES BS EN 60669-1 l PACK QTY 36mm deep With 20mm knockouts For surface mounting single gang size flush accessories 10 9221/BG As above less knockouts 10 9221/PBG 36mm deep With 20mm knockouts For surface mounting double gang size flush accessories 5 9223/BG As above less knockouts 5 9223/PBG Dimensions 86mm x 86mm x 36mm 9221/PBG 9223/BG Dimensions 146mm x 86mm x 36mm When using these boxes to mount Rockergrid assemblies spacers should be used to ensure correct depth alignment of grid. I N S TA L L AT I O N B O X E S SURFACE STEEL PEDESTAL UNITS Single sided 1 gang LPU1 LPU2 1 LPU1 Double sided 1 gang 1 LPUD1 Single sided dual 1 gang 1 LPU2 Double sided dual 1 gang 1 LPUD2 Single sided 2 gang 1 LPU2TA Double sided 2 gang 1 LPUD2TA Dimensions Single sided 1 gang 115mm x 100mm x 90mm Single sided dual 1 gang 115mm x 192mm x 90mm Single sided 2 gang 115mm x 160mm x 90mm Double sided 1 gang 115mm x 100mm x 148mm Double sided dual 1 gang 115mm x 192mm x 148mm Double sided 2 gang 115mm x 160mm x 148mm ● ● ● LPUD2 ● ● 68 l PACK QTY Bases recessed 12.3mm. See List No. Fixing centres 60. Finished in grey epoxy polyester.7mm. 9221/BG and 9223/BG 100 1250 1 6913 Screwdriver for Rockergrid VR screws *All screws are available to match the appropriate Capital and Diamond metal plate finishes – see product section. CAPITAL CEILING SWITCH ACCESSORY ITEMS 7410/WH 6900/1WH 6900 2m long red pull cord and acorn 6900/1RD 2m long white pull cord with red acorn 6900/1WH 100m ball of white pull cord 6900/2 100m ball of red pull cord 6900/2RD Ceiling switch acorn red 7410/RD Ceiling switch acorn white 7410/WH CAPITAL NEON INDICATORS 7697 3713 6509 For 13A moulded & metal plate sockets.9040 & surface steel boxes List Nos.5m long white pull cord and acorn 66 69 . 13A fuse connection units.ACCESSORY FIXING SCREWS M3.e. 45A capital switches 3713 For 13A safetysockets & slimline cooker control units 100215 For all 50A DP switches & large plate cooker control unit 7695 For 50A ceiling switch 7697 CAPITAL NEON LENSES 4674 3711 3467 l For all 50A DP switches & large plate cooker control unit (larger lens) & 32A TP & N switches 3467 For 13A moulded & metal plate sockets. 32A. 735007/ZP 735008/SC SUNDRY SCREWS & SPACERS l PACK QTY 706097 705094/BZ 15485–2/L/4 15244/PB 1250 Rockergrid switch to grid 100 706097 Capital 50A switch to grid & grid to box 4950/BG series 100 735006/ZP Rockergrid grid to box 100 735007/ZP Capital plate to box on 4214 & 4216 ranges 100 735008/* Rockergrid plate to grid 100 705094/* Rockergrid plate to grid (vandal-resistant) 100 705094/*/VR Diamond grid to box 100 15485–2/L/4 Diamond plate to grid 100 15244* Spacer for surface mounting Rockergrid switches on moulded pattress List No. 20A. fuse connection units.735010SC. 20A capital switches & slimline cooker control unit (smaller lens) 3711 For slimline cooker control unit (large lens) & capital 45A switches 3767 For 50A ceiling switch & large plate cooker control unit (smaller lens) 4674 SPARE EARTH TERMINALS 6988 6989 l For 32A TP & N switches (4514. 4513 & 4515 series) l Brass (for use with 4 lug metal box) 100 6988 Brass 100 6989 CRABTREE SERVICE ITEMS 7410/RD l 1.5mm l PACK QTY 735010/BZ/VR 735011/SC/VR 735011/BZ 20mm long (vandal resistant) 100 735009/*/VR 25mm long (vandal resistant) 100 735010/*/VR 30mm long (vandal resistant) 100 735011/*/VR 25mm long 735010* 20mm long 100 735032 30mm long 735011* 23mm long 100 735038 50mm long 735012* 25mm long 100 735033 40mm long 735013* 30mm long 100 735023 * Add finish required i. Consisting of patch panels. patch leads and a wide variety of Communications. 70 . the new Crabtree Datapak range compliments the complete Capital and Platinum range of products. Data and co-axial outlets. 7176 7086 7174 DATA AND CO-AXIAL MODULES l PACK QTY 7069 7065 7067 BNC single module with 75 Ohm crimp connector 25 7074 TV outlet (male) 25 7065 TV outlet (female) 25 7067 F type satellite 25 7069 Triplex unit (TV. return 25 7060 Phono (Female) 25 7087 Dimensions 25mm x 50mm (1 Module) (except 7063 – 50mm x 50mm) 7074 7063 7087 BLANK MODULES & ACCESSORIES l PACK QTY 1/2 module size 7081/2 1 module size 25 7081 IDC tool 20 6915 IDC crimp tool 1 7915 Dimensions 7081/2 12.Add suffix BK to list No ie triplex unit.COMMUNICATION MODULES l PACK QTY 7080 7071 7172 BT master voice 25 7080 BT master voice. 6 wire 25 7071 RJ45 (single) module. Sat) 25 7063 TV outlet screened. left handed 25 7080/LH BT secondary voice. FM.in black = 7063/BK See page 111 for Technical details.5mm x 50mm 7081 25mm x 50mm 7081/2 7081 D ATA PA K 25 Also available in Black . 8 wire – category 5e 25 7172 RJ45 ISDN terminated 25 7174 RJ11/12 25 7086 PABX voice 25 7176 RJ45 (twin) module 25 7173 Dimensions 25mm x 50mm (1 Module) All RJ45 modules are configured to wiring standard 258 A. 71 . * Bronze (BZ). Indicate the finish you require by adding suffix to List No. or SB629 dry lining * Metal plates complete with mounting grid and available in Satin Chrome (SC). 4 module 88mm x 148mm Finishes available are: Satin Chrome (SC) Highly Polished Chrome (HPC) & Polished Brass (PB). 8507/PB 8509/SS shown fitted with mounting grid D ATA PA K MOUNTING GRIDS – PLATINUM 72 l PACK QTY 2 module 10 1091/1 4 module 10 1092/1 Supplied complete with earth terminal. 4 module 86mm x 146mm Finishes available are: Stainless Steel (SS) Polished Stainless Steel (PSS) & Polished Brass (PB). Highly Polished Chrome (HPC) and Oyster Gold (YR) finishes. 1 & 2 module 86mm x 146mm. SB625 flush galv. 8094*. 8091/BZ 8094/YR MOUNTING GRIDS – SEPARATE SALE l PACK QTY 8092/1 8091/1 1 module grid 10 8091/1 2 module grid 10 8092/1 4 module grid 10 8094/1 Separate sale grids enable communications modules to be mounted in OEMs own decorative plates. 1091/1 1092/1 . 9041 surface. Supplied complete with earthing tag. or SB619 dry lining 7094. 7507/SC 7509/HPC shown fitted with mounting grid MOUNTING PLATES – PLATINUM FLAT PLATE BS 5733 WHERE APPLICABLE 2 module 4 module Dimensions l PACK QTY 10 8507/_ _ 10 8509/_ _ 2 module 86mm x 86mm. 8092*.MOUNTING PLATES – CAPITAL l BS 5733 WHERE APPLICABLE 7091 7094 PACK QTY 2 module moulded 10 7091 4 module moulded 10 7094 1 module metal plate (fitted with grid) 5 8091/_ _ 2 module metal plate (fitted with grid) 5 8092/_ _ 4 module metal plate (fitted with grid) 5 8094/_ _ Dimensions 86mm x 86mm. MOUNTING PLATES – PLATINUM LOW PROFILE BS 5733 WHERE APPLICABLE 2 module 4 module Dimensions l PACK QTY 10 7507/_ _ 10 7509/_ _ 2 module 88mm x 88mm. 9040 surface. 4 module Mounting boxes 7090. 7091. SB615 flush galv. 8091*. ie 8091 – 1 module metal plate Bronze = 8091/BZ. For Dimensions see page 126. Yellow (YW). VHF socket outlets for network systems (group aerials & sockets). 1u Cat5e UTP 1 7324 48 port. or SB619 dry lining BT approved by the Department for Trade and Industry. Blue (BL) and Green (GN). Red (RD). 7283 7284 7284 rear view 7288 PATCH PANELS l PACK QTY 7348 7324 18 port. 7501/2/BL 7502/BK 7505 D ATA PA K 0.5 metre For Technical information see page 111.RJ45 to RJ45 CAT 5e l PACK QTY 1 7501/2 1 metre 1 7501 2 metre 1 7502 3 metre 1 7503 5 metre 1 7505 Grey is standard lead colour. SB655 flush galv. 73 . 1u Cat5e UTP 1 7318 24 port. SB655 flush galv. VHF 2 way isolated UHF. Isolated units only suitable on installations with earth bond. or SB619 dry lining 7265 7266 Isolated UHF. VHF 1 way F type Satellite 2 way F type Satellite Twin TV/ Satellite PACK QTY 10 10 10 10 10 10 10 7265 7266 7267 7268 7269 7270 7271 Dimensions 86mm x 86mm Mounting boxes 9047 surface. 1u 1 7305 7318 7305 PATCH LEADS . TELEPHONE SOCKET OUTLETS l PACK QTY 20 10 10 10 10 IDC tool Single master Single secondary RJ11 Telephone socket Dual outlet adaptor Dimensions 6915 7283 7284 7286 7288 86mm x 86mm Mounting boxes 9047 surface. 1u Cat5e UTP 1 7348 4 ring cable tidy. Other colours available are: Black (BK).CO-AXIAL SOCKET OUTLETS l BS 3041 WHERE APPLICABLE 1 way direct connection 2 way direct connection 1 way isolated UHF. 4. Ceiling assembly cover secures to outlet with assembly offering either standard or safety lampholder options 74 Ceiling outlet can be easily assembled to pattress and plug provides a simple plug in connection . 5 and 7 pin versions. The range conforms to BS 7001 and BS 5733 and provides an effective plug-in connection with arrangements including 3.Luminaire Support Couplers Crabtree LSCs. commercial and industrial lighting applications. provide flexibility and versatility to meet the demands of many domestic. • Interiors are installed into Crabtree Luminaire Distribution Boxes.CEILING ASSEMBLIES 5001 complete assembly Description 3 pin 3 pin with 2m 3 pin with 2m 3 pin with 3m 3 pin with 3m 3 pin with 5m 3 pin with 5m 1. please contact Technical Services. • 4 pin LSC plug has a red cover as standard.0mm2 1. PENDANT SETS l Description List No 3 pin assembly with 6” flex and Standard Pendant 5007 3 pin assembly with 6” flex and Safety Pendant 5008 Surface mounting pattress 5005 5008 CRABTREE LUMINAIRE SUPPORT COUPLERS 5003 Description For further details of pattress see Technical page 111.0mm2 Heat Resistant (HR) cable 4 pin with 2m 1. LDBs.0mm2 Heat Resistant (HR) cable 4 pin with 5m 1.0mm2 1.0mm2 1. 5004 5012 5013 LSC PLUGS 5010 5006 l Description List No 3 pin 5006 4 pin (with red cover) 5010 5 pin 5014 7 pin 5016 • Cable clamp to grip outer cable insulation for maximum support.0mm2 l Heat Resistant (HR) cable Low Smoke (LSF) cable Heat Resistant (HR) cable Low Smoke (LSF) cable Heat Resistant (HR) cable Low Smoke (LSF) cable 4 pin 4 pin with 2m 1.0mm2 Low Smoke (LSF) cable 4 pin with 3m 1. 75 .0mm2 Heat Resistant (HR) cable 4 pin with 3m 1. CEILING OUTLETS & INTERIORS l 5011 List No 3 pin ceiling outlet 5003 4 pin ceiling outlet 5011 3 pin interior 5004 4 pin interior 5012 5 pin interior 5013 7 pin interior 5015 • For further details on 5 and 7 pin interiors see Technical page 111.0mm2 1. • Other lengths and cable options available upon request. • Prewired versions are available. LSC plug and cover.0mm2 1.0mm2 Low Smoke (LSF) cable Cover only for LSC ceiling assembly 5002 List No 5001 5002 5017 5002/3 5017/3 5002/5 5017/5 5009 5018 5019 5018/3 5019/3 5018/5 5019/5 5001/CVR • Ceiling assemblies supplied as outlet.0mm2 Low Smoke (LSF) cable 4 pin with 5m 1. Luminaire Distribution Boxes LSC Interiors are mounted in a combination of 6. ● Internal connections are made to a terminal block for ease of wiring ● Sufficient side and rear knockouts allow entries for cable or conduit ● 76 Raised mounting feet allow for installation on uneven surfaces . LDB. 8 and 10 outlet configurations contained within a steel fabricated enclosure to provide a Luminaire Distribution Box. 5020/7 LSC PLUGS 5010 5006 l Description List No 3 pin 5006 3 pin C/W 2m HR cable 5006/2 3 pin C/W 3m HR cable 5006/3 3 pin C/W 4m HR cable 5006/4 4 pin (with red cover) 5010 4 pin C/W 2m HR cable 5010/2 4 pin C/W 3m HR cable 5010/3 4 pin C/W 4m HR cable 5010/4 5 pin 5014 7 pin 5016 • • • • Cable clamp to grip outer cable insulation for maximum support. CRABTREE LUMINAIRE DISTRIBUTION BOXES Description For Dimensions see page 126. 3 pin LSC plugs can be installed into all LSC interiors. 4 pin LSC plug has a red cover as standard. For further details or quotation please contact our Technical Services on 01543 455200.3 PIN LUMINAIRE DISTRIBUTION BOXES l Description List No 3 pin 6 way 5020/3 3 pin 8 way 5021/3 3 pin 10 way 5022/3 5022/3 4 PIN LUMINAIRE DISTRIBUTION BOXES l Description List No 4 pin 6 way 5020/4 4 pin 8 way 5021/4 4 pin 10 way 5022/4 5020/4 5 PIN LUMINAIRE DISTRIBUTION BOXES l List No 5 pin 6 way 5020/5 5 pin 8 way 5021/5 5 pin 10 way 5022/5 5021/5 7 PIN LUMINAIRE DISTRIBUTION BOXES l Description List No 7 pin 6 way 5020/7 7 pin 8 way 5021/7 7 pin 10 way 5022/7 Other configurations of LDB are available upon request. Different lengths & types of cable are available please contact Technical Services. 77 . 78 . WA RW I C K M O D U L A R P V C R A N G E 79 .WARWICK PVC modular trunking range which can be mounted at either Dado or Skirting level. available in 2 different sizes (50mm x 170mm) or (50mm x 212mm) they can be purchased as a standard system for hard wiring or with a 63Amp bus-bar system fitted to the centre compartment of the trunking. Right Square Cable Retainer AN I TCE M WA RW I C K M OCDIUL L A R YP V R SA NAGNED S PA R E S WARWICK 1 – Single Gang Accessory Box BCL/SGB BCL/SGB BCL/SGB BCL/SGB BCL/SGB Twin Gang Accessory Box BCL/TGB BCL/TGB BCL/TGB BCL/TGB BCL/TGB ANGLED COVER SECTION Pack Quantity 5 x 3m BCL/ACS MAIN COVER Pack Quantity 5 x 3m BASE EXTENSION Pack Quantity 5 x 3m VERTICAL MOUNT ADAPTOR PLATE Pack Quantity 1 BCL/ADPL BCL/BE METAL SCREENING Should metal screening be required.QUICK GUIDE TO FIVE PVC PROFILES WARWICK 2 WARWICK 3 WARWICK 4 WARWICK 5 Ref No Ref No Ref No Ref No Ref No Trunking Pack BCL1 BCL2 BCL3 BCL4 BCL5 Internal Bend BCL1/IB BCL2/IB BCL3/IB BCL4/IB BCL5/IB External Bend BCL1/EB BCL2/EB BCL3/EB BCL4/EB BCL5/EB Flat Angle 90° (Downward) BCL1/FAD BCL2/FAD BCL3/FAD BCL4/FAD BCL5/FAD – BCL2/FAU – BCL4/FAU BCL5/FAU BCL1/FTD BCL2/FTD BCL3/FTD BCL4/FTD BCL5/FTD – BCL2/FTU – BCL4/FTU BCL5/FTU BCL1/SEL BCL2/SEL BCL3/SEL BCL4/SEL BCL5/SEL – BCL2/SER – BCL4/SER BCL5/SER Coupler Pack BCL1/CP BCL2/CP BCL3/CP BCL4/CP BCL5/CP Angled Cable Retainer BCL/ACR BCL/ACR – BCL/ACR – Standard Cable Retainer BCL/SCR BCL/SCR BCL/SCR BCL/SCR BCL/SCR BCL/SQCR BCL/SQCR BCL/SQCR BCL/SQCR Flat Angle 90° (Upward) Flat Tee (Downward) Flat Tee (Upward) Stop End .Left Stop End . aluminium sections can be supplied for both top and bottom sections of the trunking to ensure “spiking” does not occur.2 & 3 . For Technical information see page 113. Dimensions see page 80 BCL/MC SQUARE COVER SECTION Pack Quantity 5 x 3m BCL/SCS RCD HOUSING Pack Quantity 1 ANGLED SECTION SCREEN BCL/RCD BCL/ASS Supplied in 1m lengths SQUARE SECTION SCREEN BCL/SSS Supplied in 1m lengths The above metal screen sections are suitable for profiles 1. If screened data/telephone cables are being used within the wiring system internal metal screening is not needed. Profile assembly includes: • Base Section • 2 x Angled Covers 42 mm 50 mm • 1 x Main Cover 42 mm 85 mm 170 mm Overall Size: • 170mm x 50mm TRUNKING PACK Pack Quantity 1 x 3m length BCL1 BCL1/IB EXTERNAL BEND Pack Quantity 1 BCL1/EB FLAT ANGLE Pack Quantity 1 BCL1/FAD FLAT TEE Pack Quantity 1 BCL1/FTD STOP END Pack Quantity 1 BCL1/SEL COUPLER PACK Pack Quantity 1 BCL1/CP ANGLED CABLE RETAINER Pack Quantity 10 BCL/ACR SINGLE GANG ACCESSORY BOX Pack Quantity 10 BCL/SGB TWIN GANG ACCESSORY BOX Pack Quantity 5 BCL/TGB WA RW I C K 1 P V C T R U N K I N G INTERNAL BEND Pack Quantity 1 For Technical information see page 113. Dimensions see page 81 . Profile assembly includes: • Base Section • 1 x Angled Cover 42 mm 50 mm • 1 x Main Cover 85 mm Overall Size: • 170mm x 50mm WA ARRW WIICCK K M 2 OP D VC I N RGA N G E W U LTARRU N P VKC 42 mm 170 mm • 1 x Square Cover TRUNKING PACK Pack Quantity 1 x 3m length INTERNAL BEND Pack Quantity 1 BCL2/IB EXTERNAL BEND Pack Quantity 1 BCL2/EB FLAT ANGLE (DOWNWARD) Pack Quantity 1 BCL2/FAD FLAT ANGLE (UPWARD) Pack Quantity 1 BCL2/FAU FLAT TEE (UPWARD) Pack Quantity 1 BCL2/FTU FLAT TEE (DOWNWARD) Pack Quantity 1 BCL2/FTD STOP END (LEFT) Pack Quantity 1 BCL2/SEL STOP END (RIGHT) Pack Quantity 1 BCL2/SER COUPLER PACK Pack Quantity 1 ANGLED CABLE RETAINER Pack Quantity 10 BCL/ACR BCL2/CP SQUARE CABLE RETAINER Pack Quantity 10 BCL/SQCR SINGLE GANG ACCESSORY BOX Pack Quantity 10 BCL/SGB For Technical information see page 113. Dimensions see page 82 BCL2 TWIN GANG ACCESSORY BOX Pack Quantity 5 BCL/TGB 50 mm Profile assembly includes: • Base Section 42 mm • 2 x Square Covers • 1 x Main Cover 85 mm 42 mm 170 mm Overall Size: • 170mm x 50mm TRUNKING PACK Pack Quantity 1 x 3m length BCL3 BCL3/IB EXTERNAL BEND Pack Quantity 1 BCL3/EB FLAT ANGLE Pack Quantity 1 BCL3/FAD FLAT TEE Pack Quantity 1 BCL3/FTD STOP END Pack Quantity 1 BCL3/SEL COUPLER PACK Pack Quantity 1 BCL3/CP SQUARE CABLE RETAINER Pack Quantity 10 BCL/SQCR SINGLE GANG ACCESSORY BOX Pack Quantity 10 BCL/SGB TWIN GANG ACCESSORY BOX Pack Quantity 5 BCL/TGB WA RW I C K 3 P V C T R U N K I N G INTERNAL BEND Pack Quantity For Technical information see page 113. Dimensions see page 83 50 mm 42 mm Profile assembly includes: • Base Section • 1 x Base Extension 85 mm • 2 x Main Covers Overall Size: • 212mm x 50mm 85 mm 212 mm • 1 x Angled Cover 4O PV I NR GA N G E WA RW I C K M DC U LTARRU N P VKC TRUNKING PACK Pack Quantity 1 x 3m length INTERNAL BEND Pack Quantity 1 BCL4/IB EXTERNAL BEND Pack Quantity 1 FLAT ANGLE (UPWARD) Pack Quantity 1 BCL4/FAU FLAT TEE (DOWNWARD) Pack Quantity 1 BCL4/FTD FLAT TEE (UPWARD) Pack Quantity 1 BCL4/FTU STOP END (LEFT) Pack Quantity 1 BCL4/SEL STOP END (RIGHT) Pack Quantity 1 COUPLER PACK Pack Quantity 1 BCL4/CP ANGLED CABLE RETAINER Pack Quantity 10 BCL/ACR BCL4/EB BCL4/SER SINGLE GANG ACCESSORY BOX Pack Quantity 10 BCL/SGB For Technical information see page 113. Dimensions see page 84 BCL4 FLAT ANGLE (DOWNWARD) Pack Quantity 1 BCL4/FAD TWIN GANG ACCESSORY BOX Pack Quantity 5 BCL/TGB 50 mm 42 mm Profile assembly includes: • Base Section • 1 x Base Extension 85 mm • 2 x Main Covers Overall Size: • 212mm x 50mm 85 mm 212 mm • 1 x Square Cover TRUNKING PACK Pack Quantity 1 x 3m length BCL5 BCL5/IB EXTERNAL BEND Pack Quantity 1 FLAT ANGLE (UPWARD) Pack Quantity 1 BCL5/FAU FLAT TEE (DOWNWARD) Pack Quantity 1 BCL5/FTD FLAT TEE (UPWARD) Pack Quantity 1 BCL5/FTU STOP END (LEFT) Pack Quantity 1 BCL5/SEL STOP END (RIGHT) Pack Quantity 1 COUPLER PACK Pack Quantity 1 BCL5/CP SQUARE CABLE RETAINER Pack Quantity 10 BCL/SQCR BCL5/EB BCL5/SER SINGLE GANG ACCESSORY BOX 30mm Deep Pack Quantity 10 BCL/SGB FLAT ANGLE (DOWNWARD) Pack Quantity 1 BCL5/FAD TWIN GANG ACCESSORY BOX 30mm Deep Pack Quantity 5 BCL/TGB WA RW I C K 5 P V C T R U N K I N G INTERNAL BEND Pack Quantity 1 For Technical information see page 113. Dimensions see page 85 . The bars are clearly marked on the connector blocks and the snap-in boxes. and can be ordered in varying lengths to suit the installation.5 metre length BCL/BB05 For installations requiring Bus-Bar. • The Warwick Bus-Bar has been designed to fit into any of the five standard Warwick PVC trunkings. • Available with a full range of accessories for easy installation.B A R T R U N K I N G Bus-Bar lengths are supplied separately to allow flexibility on site. A standard 3-bar system can be achieved if required. we strongly recommend the order is handled by the PROJECT SALES TEAM who offer a free installation design service. Neutral. The Bus-Bar Assembly will fit into any Warwick PVC profile. • Single and double plug-in accessory boxes which locate into the Bus-Bar track and allow cable termination to standard 13A sockets. • The Bus-Bar has a standard configuration with 4 bars . . Earth and a separate bar for a clean Earth requirement and Regulation 607. • Safety Bus-Bar cover 86 3 metre length • Fully integrated system • WARWICK standard trunkings can be upgraded to a Bus-Bar system utilising full range of separate parts.Live. BCL/BB3 1 metre length BCL/BB1 0.1 4 1 Bus-Bar Assembly 2 Bus-Bar Cover 3 Connector Block 4 Corner Assembly 5 Single Gang Accessory Box 2 3 5 WA RW I C K B U S . Bus-Bar Assembly fitted into Warwick Trunking BUS-BAR ASSEMBLY Bus-Bar Assembly 0. Dimensions see page 87 .B A R T R U N K I N G MAINS CONNECTOR BLOCK BCL/BBMC Pack Quantity 1 BCL/TGB For Technical information see page 113. BOX 30mm Deep Standard Pack 10 BCL/SGB COUPLER PACK Standard Pack 5 TWIN-GANG ACCESSORY BOX Standard Pack 5 BCL/BBTB TWIN-GANG BOX 30mm Deep Standard Pack 5 BCL/BBCB WA RW I C K B U S .5m BCL/BB05 END STOP (LEFT) Standard Pack 1 BCL/BBSL Bus-Bar Assembly 1m BCL/BB1 END STOP (RIGHT) Standard Pack 1 BCL/BBSR Bus-Bar Assembly 3m BCL/BB3 CORNER ASSEMBLY Cable size 16mm2 400mm Cable Length Standard Pack 1 BCL/BBCA SINGLE GANG ACCESSORY BOX Standard Pack 10 BCL/BBSB SINGLE GANG DATA/TEL. 88 . split . 89 . if required. By employing a unique busbar system a balance is achieved between the conventional ’factory built‘ approach and the time consuming on-site assembly of many individual components. main incoming device and.load RCCB.DOMESTIC CIRCUIT PROTECTION S TA R B R E A K E R D O M E S T I C C I R C U I T P R O T E C T I O N The Starbreaker domestic circuit protection range introduces an innovative modular concept to the market. busbar. Starbreaker consumer units can be quickly and easily made up on site by selection of an enclosure. white PVC cover & shield 20 module. ALL INSULATED ENCLOSURES l H W 4 modular ways 6 modular ways 9 modular ways 12 modular ways 15 modular ways 20 modular ways 160 230 230 230 230 230 117 190 243 294 344 439 D 102 120 120 120 120 120 404/0A* 406/0A 409/0A 412/0A 415/0A 420/0A Large selection of knock-outs suiting any cable routing – also readily accommodates mini-trunking. SPINE BACKPLATE CHASSIS l 15 module. * Includes Busbar. unique circuit identification labels and user guide. Suitable for use with control modules. all finished in a stylish semi-matt finish. Ample wiring space. . Available in standard Metal format or with extended PVC front plate and shield. Dimensions see page 129. * Includes Busbar. – 16mm2 earth and neutral bar terminal assembly. In split-load applications the RCCB neutral connections must also be reversed. ● Adequate knock-outs in robust metal box for side or rear entry of wiring.ENCLOSURES l The range of enclosures from 4 to 20 modules as all insulated and 4 to 40 modules as metal cased with a new improved steel front cover. – Installation instructions. If siting is required on the right this lead should be replaced by one of suitable length (16mm2). ● ● ● ● 415/0A S TA R B R E A K E R M A I N I N C O M I N G & O U T G O I N G D E V I C E S ● 90 Type tested to BS 5486 Part 13: 1989 and BS EN 60439-3 when fully assembled. Each enclosure is supplied complete with: – 35mm metal DIN rail. grey metal cover 15 module. PVC cover & shield with 435mm centres ● ● ● ● 915/0M 915/0W 809/0AF 812/0AF 815/0AF 820/0AF 915/0M 915/0W 920/0W/435 Designed for installation into meter cabinets (eg Clifton). – Factory-fitted 16mm2 flexible neutral connection. ● ● FLUSH METAL CASED 9 modular ways 12 modular ways 15 modular ways 20 modular ways 830/2A ● l H W D 250 250 250 250 281 332 393 478 121 121 121 121 Adequate knock-outs in robust metal box for side or rear entry of wiring. Provide a method of updating such installations with MCB and RCCB protection. All enclosures are supplied ready prepared for the unique busbar to be easily fitted into place. ● 420/0A SURFACE METAL CASED 4 modular ways 6 modular ways 9 modular ways 12 modular ways 15 modular ways 20 modular ways 24 modular ways 2 Bank 30 modular ways 2 Bank 40 modular ways 2 Bank l H W D 210 210 210 210 210 210 450 450 450 117 188 241 292 353 438 292 353 438 121 121 121 121 121 121 121 121 121 804/0A* 806/0A 809/0A 812/0A 815/0A 820/0A 824/2A 830/2A 840/2A Raised keyhole slots for easy mounting on uneven surfaces. The neutral lead fitted to all enclosures facilitates siting the main incoming device on the left hand side. Type C classification (5–10In). 6kA – 240V 50Hz. 30mA 310/030 310/A030 100A DP. 91 . 30mA 363/S030 363/AS030 63A DP. 30mA 380/030 380/A030 80A DP. 610/ _ _ with the required rating between 6A and 40A. 100mA 363/S100 363/AS100 80A DP. ● 61/C06 61/C10 61/C16 61/C20 61/C32 61/C40 61/C50 RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION (RCBO) CURRENT RATING (A) 6 10 16 20 32 40 ● ● 61/C13230 l TWO MODULE SINGLE MODULE LIST No LIST No 30mA 61/B0630 61/B1030 61/B1630 61/B2030 61/B3230 61/B4030 10mA 61/B0610 61/B1010 61/B1610 61/B2010 61/B3210 61/B4010 30mA 61/C10630 61/C11030 61/C11630 61/C12030 61/C13230 61/C14030 BS EN 61009. 100mA 340/100 340/A100 63A DP. Type B classification (3–5In).MAIN INCOMING & SPLIT-LOAD DEVICES 100/M2 100/2MT 100/SP1 100/DC1 100/DC2 DESCRIPTION RATING Main switch disconnector 40A DP Main switch disconnector 63A DP Main switch disconnector 100A DP Main switch disconnector 100A SP Main switch disconnector c/w tap off terminal 100A DP Direct connection unit 100A DP Direct connection unit 100A SP ● 100A main switches to BS EN 60947-3 MODULES 2 2 2 1 2 2 1 ● 100/2MT 100/DC2 100/DC1 50mm2 terminal capacity. 100mA 310/100 100A DP. 2 module device. 30mA 363/030 363/A030 80A DP. IEC 1008. 16mm2 terminal capacity. CAUTION These devices are electronic units and should be disconnected from the supply during insulation and earth fault loop impedance testing. IEC 1009. ● Suffix List No. 100mA 310/100TD 63A DP. ● Type 2 classification available in 6A and 16A ratings eg 610/062 = 6A single pole Type 2 MCB. 30mA 380/S030 380/AS030 80A DP. 30mA 340/030 340/A030 40A DP. eg 610/32 = 32A single pole Type 1 MCB. ● 50mm2 terminal capacity. l LIST No 40/M2 63/M2 100/M2 100/SP1 RCD TYPE A RATING LIST No LIST No 25A DP. 100mA 380/S100 380/AS100 ● Electro-mechanical. 10mm2. OUTGOING DEVICES l MINIATURE CIRCUIT BREAKERS l LIST No 61/B06 61/B10 61/B16 61/B20 61/B32 61/B40 61/B50 CURRENT RATING (A) 6 MODULES 1 Type B 61/B06 Type C 61/C06 10 1 61/B10 61/C10 16 1 61/B16 61/C16 20 1 61/B20 61/C20 32 1 61/B32 61/C32 40 1 61/B40 61/C40 50 1 61/B50 61/C50 ● ● BS EN 60898. 100mA 380/100 100A DP. Replacement MCBs for Starbreaker consumer units pre July 1992 SB6000 range to BS 3871. S TA R B R E A K E R E N C L O S U R E S ● Full Technical Information see page 114-119. RCD TYPE AC 380/030 363/S030 DESCRIPTION Main incoming RCCB Main incoming RCCB Main incoming RCCB Main incoming RCCB Main incoming RCCB Main incoming RCCB Main incoming RCCB Main incoming RCCB Main incoming TD RCCB Split-load RCCB Split-load RCCB Split-load RCCB Split-load RCCB ● BS EN 61008. 30mA 325/030 325/A030 40A DP. 1 module device 35mm2 terminal capacity. Other arrangements of split busbar are available to order. twin and multi tariff. 9090 & 9060 S TA R B R E A K E R B U S B A R S E L E C T I O N G U I D E MAIN INCOMING 92 Modular ways List No 100A double pole main switch incomer MCB ways Layout RCCB main incomer MCB ways Layout 6 9060 4 4 9 9090 7 7 12 9120 10 10 15 9150 13 13 20 9200 18 18 100A double pole main switch + 100A double pole main switch MCB ways Layout SPLIT-LOAD & DUAL TARIFF Modular ways List No 100A double pole main switch + 63A or 80A split-load RCCB MCB ways Layout 9 9530 2+2 3+2 12 9560 2+5 3+5 12 9650 3+4 4+4 12 9740 4+3 5+3 12 9830 5+2 6+2 15 9680 3+7 4+7 15 9770 4+6 5+6 15 9860 5+5 6+5 15 9950 6+4 7+4 15 9104 7+3 8+3 20 9811 5 + 10 6 + 10 20 9910 6+9 7+9 20 9109 7+8 8+8 20 9118 8+7 9+7 20 9127 9+6 10 + 6 20 9136 10 + 5 11 + 5 KEY Main switch RCCB The 100A Double Pole main switch can be replaced by a main incoming RCCB without impacting on the number of MCB ways available .STARBREAKER BUSBAR SELECTION 9815M 9118 9860 l Busbars are supplied ready assembled in a variety of configurations to cater for the majority of arrangements from main incomer to split-load. Supplied leads are for split load applications only. Once in position the busbar is suspended at a height which allows 25mm2 cable to be routed underneath. STANDARD METER SERVICE CUT OUT FUSE 100A INCOMING SUPPLY SPLIT-LOAD DUAL RCCB Modular ways List No 100A double pole main switch + 63A or 80A split-load RCCB + 80A double pole RCCB incomer MCB ways Layout 15 9355/ST 4+4 20 9387/ST 7+6 2 BANK SPLIT-LOAD DUAL RCCB Modular ways List No 100A double pole main switch + 63A or 80A split-load RCCB MCB ways Layout 12 9380/D 7 15 9311/D 10 20 9316/D 15 KEY Main switch RCCB The 100A Double Pole main switch can be replaced by a main incoming RCCB without impacting on the number of MCB ways available S TA R B R E A K E R B U S B A R S E L E C T I O N G U I D E Modular ways 93 . SERVICE CUT OUT FUSE 100A INCOMING SUPPLY SPLIT-LOAD DUAL TARIFF List No 100A double pole main switch + 63A or 80A split-load RCCB + 100A double pole main switch MCB ways Layout 15 9233/ST 2+3+3 20 9837/ST 5+2+6 20 9675/ST 3+6+4 MAIN SWITCH HEATING CONTROL METER SPLIT LOAD RCCB MAIN SWITCH Combining the added safety of a split-load RCCB and the economy heating tariff into one combined unit offers an all-round saving of space and installation time. In this instance the bottom immersion heater neutral should be connected directly to the bottom neutral terminal on the appropriate main switch.MULTI TARIFF HEATING CONTROL Modular ways List No 100A double pole main switch + 100A double pole main switch + 100A double pole main switch MCB ways Layout 15 9414/M 4+1+4 20 9815/M 8+1+5 20 9716/M 7+1+6 RADIO TELESWITCH Multi-tariff heating provides 3 tariffs catering for total heating applications TO STANDARD CONSUMER UNIT 1 Direct heating appliances MAIN SWITCH HEATING CONTROL METER STANDARD METER MAIN SWITCH MAIN SWITCH 2 Bottom Immersion Heater 3 Storage heating 1 2 3 NOTE 15 module enclosures will accommodate this facility. however the enclosure is not fitted with three neutral bars. ALL-INSULATED l The following selection tables enable easy identification of the components required to build a variety of consumer units. 63A double pole RCCB control for selected MCB ways) 410/2563 2+2 63A 30mA 404/2263 409/0A 9530 100/MI2 363/S030 2+5 63A 30mA 407/2263 412/0A 9560 100/MI2 363/S030 3+4 63A 30mA 407/2363 412/0A 9650 100/MI2 363/S030 4+3 63A 30mA 407/2463 412/0A 9740 100/MI2 363/S030 5+2 63A 30mA 407/2563 412/0A 9830 100/MI2 363/S030 3+7 63A 30mA 410/2363 415/0A 9680 100/MI2 363/S030 4+6 63A 30mA 410/2463 415/0A 9770 100/MI2 363/S030 5+5 63A 30mA 410/2563 415/0A 9860 100/MI2 363/S030 6+4 63A 30mA 410/2663 415/0A 9950 100/MI2 363/S030 7+3 63A 30mA 410/2763 415/0A 9104 100/MI2 363/S030 5 + 10 63A 30mA 415/2563 420/0A 9811 100/MI2 363/S030 6+9 63A 30mA 415/2663 420/0A 9910 100/MI2 363/S030 7+8 63A 30mA 415/2763 420/0A 9109 100/MI2 363/S030 8+7 63A 30mA 415/2863 420/0A 9118 100/MI2 363/S030 9+6 63A 30mA 415/2963 420/0A 9127 100/MI2 363/S030 10 + 5 63A 30mA 415/2163 420/0A 9136 100/MI2 363/S030 Factory-built consumer units are available to order – Add B to the consumer unit List No. For 80A split-load consumer units. Type A RCCBs are available – Add A to the consumer unit List No. eg 410/A2663. eg 404/2B. The above RCCBs are Type AC. . use 380/S030 or 380/S100 split-load RCCBs. = + + SURFACE Available MCB ways Rating Consumer unit List No Surface moulded enclosure Busbar Main incoming Split-load device RCCB Main switch consumer units S TA R B R E A K E R C O N S U M E R U N I T S E L E C T I O N G U I D E (100A double pole main switch control for all MCB ways) 94 2 40A 402/2 404/0A - 40/MI2 - 4 100A 404/2 406/0A 9060 100/MI2 - 7 100A 407/2 409/0A 9090 100/MI2 - 10 100A 410/2 412/0A 9120 100/MI2 - 13 100A 413/2 415/0A 9150 100/MI2 - 18 100A 418/2 420/0A 9200 100/MI2 - 407/2 RCCB consumer units (Double pole RCCB control for all MCB ways) 407/383 2 40A 30mA 402/343 404/0A - 340/030 - 2 63A 30mA 402/363 404/0A - 363/030 - 4 40A 30mA 404/343 406/0A 9060 340/030 - 4 80A 30mA 404/383 406/0A 9060 380/030 - 7 40A 30mA 407/343 409/0A 9090 340/030 - 7 80A 30mA 407/383 409/0A 9090 380/030 - 10 80A 30mA 410/383 412/0A 9120 380/030 - 10 100A 30mA 410/313 412/0A 9120 310/030 - 13 80A 30mA 413/383 415/0A 9150 380/030 - 13 100A 30mA 413/313 415/0A 9150 310/030 - 18 80A 30mA 418/383 420/0A 9200 380/030 - 18 100A 30mA 418/313 420/0A 9200 310/030 - Split-load consumer units (100A double pole main switch control for all MCB ways. eg 413/A26786.ALL-INSULATED l The following selection tables enable easy identification of the components required to build a variety of consumer units. 63A split-load RCCB control for selected MCB ways. 408/26484 S TA R B R E A K E R C O N S U M E R U N I T S E L E C T I O N G U I D E 3+2 95 . = + + SURFACE Available MCB ways Rating Consumer unit List No Surface moulded enclosure Busbar Main incoming device RCCB Dual tariff consumer units (100A double pole main switch control for each tariff) 100A 405/232 409/0A 9530 100/MI2 x 2 - 3+5 100A 408/232 412/0A 9560 100/MI2 x 2 - 4+4 100A 408/242 412/0A 9650 100/MI2 x 2 - 5+3 100A 408/252 412/0A 9740 100/MI2 x 2 - 6+2 100A 408/262 412/0A 9830 100/MI2 x 2 - 4+7 100A 411/242 415/0A 9680 100/MI2 x 2 - 5+6 100A 411/252 415/0A 9770 100/MI2 x 2 - 6+5 100A 411/262 415/0A 9860 100/MI2 x 2 - 7+4 100A 411/272 415/0A 9950 100/MI2 x 2 - 8+3 100A 411/282 415/0A 9104 100/MI2 x 2 - 6 + 10 100A 416/262 420/0A 9811 100/MI2 x 2 - 7+9 100A 416/272 420/0A 9910 100/MI2 x 2 - 8+8 100A 416/282 420/0A 9109 100/MI2 x 2 - 9+7 100A 416/292 420/0A 9118 100/MI2 x 2 - 10 + 6 100A 416/212 420/0A 9127 100/MI2 x 2 - 11 + 5 100A 416/2112 420/0A 9136 100/MI2 x 2 - 411/262 Multi tariff consumer units (100A double pole main switch control for each tariff) 4+1+4 100A 409/242124 415/0A 9414/M 100/MI2 x 3 - 8+1+5 100A 414/282125 420/0A 9815/M 100/MI2 x 3 - 7+1+6 100A 414/272126 420/0A 9716/M 100/MI2 x 3 - Split-load dual tariff consumer units (100A double pole main switch control for all MCB ways. (100A double pole main switch control for storage heating MCBs) 2+3+3 63A 30mA 408/22623 415/0A 9233/ST 100/MI2 x 2 363/S030 5+2+6 63A 30mA 413/25626 420/0A 9837/ST 100/MI2 x 2 363/S030 3+6+4 63A 30mA 413/23624 420/0A 9675/ST 100/MI2 x 2 363/S030 409/242124 Split-load dual RCCB consumer units (100A double pole main switch control for all MCB ways. (80A main switch RCCB control for selected MCB ways) 408/22623 4+4 63A 100mA 80A 30mA 408/26484 415/0A 9355/ST 100/2MT 363/S100 380/030 7+6 63A 100mA 80A 30mA 413/26786 420/0A 9387/ST 100/2MT 363/S100 380/030 The above RCCBs are Type AC. 63A double pole RCCB control for selected MCB ways. Type A RCCBs are available – Add A to the consumer unit List No. Note The split arrangements in split-load configurations represent circuits unprotected and protected respectively eg 3 + 6 = 3 MCB ways unprotected and 6 MCB ways protected by the RCCB. eg 807/2B. 100mA version RCCB’s available replace final digit 3 with 1 i.e.METAL CASED l The following selection tables enable easy identification of the components required to build a variety of consumer units. The above RCCBs are Type AC. eg 810/A2663. 810/2363 would become 810/2361 . = + + SURFACE Available MCB ways Rating Consumer unit List No Surface metal enclosure Busbar Main incoming Split-load device RCCB Main switch consumer units S TA R B R E A K E R C O N S U M E R U N I T S E L E C T I O N G U I D E (100A double pole main switch control for all MCB ways) 96 807/2 2 40A 802/2 804/0A - 40/MI2 - 4 100A 804/2 806/0A 9060 100/MI2 - 7 100A 807/2 809/0A 9090 100/MI2 - 10 100A 810/2 812/0A 9120 100/MI2 - 13 100A 813/2 815/0A 9150 100/MI2 - 18 100A 818/2 820/0A 9200 100/MI2 - RCCB consumer units (Double pole RCCB control for all MCB ways) 810/383 2 40A 30mA 802/343 804/0A - 340/030 - 2 63A 30mA 802/363 804/0A - 363/030 - 4 40A 30mA 804/343 806/0A 9060 340/030 - 4 80A 30mA 804/383 806/0A 9060 380/030 - 7 40A 30mA 807/343 809/0A 9090 340/030 - 7 80A 30mA 807/383 809/0A 9090 380/030 - 10 80A 30mA 810/383 812/0A 9120 380/030 - 10 100A 30mA 810/313 812/0A 9120 310/030 - 13 80A 30mA 813/383 815/0A 9150 380/030 - 13 100A 30mA 813/313 815/0A 9150 310/030 - 18 80A 30mA 818/383 820/0A 9200 380/030 - 18 100A 30mA 818/313 820/0A 9200 310/030 - Split-load consumer units (100A double pole main switch control for all MCB ways. 63A double pole RCCB control for selected MCB ways) 810/2363 2+2 63A 30mA 804/2263 809/0A 9530 100/MI2 363/S030 2+5 63A 30mA 807/2263 812/0A 9560 100/MI2 363/S030 3+4 63A 30mA 807/2363 812/0A 9650 100/MI2 363/S030 4+3 63A 30mA 807/2463 812/0A 9740 100/MI2 363/S030 5+2 63A 30mA 807/2563 812/0A 9830 100/MI2 363/S030 3+7 63A 30mA 810/2363 815/0A 9680 100/MI2 363/S030 4+6 63A 30mA 810/2463 815/0A 9770 100/MI2 363/S030 5+5 63A 30mA 810/2563 815/0A 9860 100/MI2 363/S030 6+4 63A 30mA 810/2663 815/0A 9950 100/MI2 363/S030 7+3 63A 30mA 810/2763 815/0A 9104 100/MI2 363/S030 5 + 10 63A 30mA 815/2563 820/0A 9811 100/MI2 363/S030 7+8 63A 30mA 815/2763 820/0A 9109 100/MI2 363/S030 6+9 63A 30mA 815/2663 820/0A 9910 100/MI2 363/S030 8+7 9+6 63A 30mA 63A 30mA 815/2863 815/2963 820/0A 820/0A 9118 9127 100/MI2 363/S030 100/MI2 363/S030 For flush mounting units up to 20 module – Add F to consumer unit and enclosure List No. For 80A split-load consumer units use 380/S030 or 380/S100 split-load RCCBs. eg 807/2F. 809/0AF. Factory-built consumer units are available to order – Add B to the consumer unit List No. Type A RCCBs are available – Add A to the consumer unit List No. 63A/80A split-load RCCB control for selected MCB ways. + = + + SURFACE Available MCB ways Rating Consumer unit List No Surface metal enclosure Busbar Main incoming device Split-load RCCB Dual tariff consumer units (100A double pole main switch control for each tariff) 100A 805/232 809/0A 9530 100/MI2 x 2 - 3+5 100A 808/232 812/0A 9560 100/MI2 x 2 - 4+4 100A 808/242 812/0A 9650 100/MI2 x 2 - 5+3 100A 808/252 812/0A 9740 100/MI2 x 2 - 6+2 100A 808/262 812/0A 9830 100/MI2 x 2 - 4+7 100A 811/242 815/0A 9680 100/MI2 x 2 - 5+6 100A 811/252 815/0A 9770 100/MI2 x 2 - 6+5 100A 811/262 815/0A 9860 100/MI2 x 2 - 7+4 100A 811/272 815/0A 9950 100/MI2 x 2 - 8+3 100A 811/282 815/0A 9104 100/MI2 x 2 - 6 + 10 100A 816/262 820/0A 9811 100/MI2 x 2 - 7+9 100A 816/272 820/0A 9910 100/MI2 x 2 - 8+8 100A 816/282 820/0A 9109 100/MI2 x 2 - 10 + 6 100A 816/212 820/0A 9127 100/MI2 x 2 - 9+7 100A 816/292 820/0A 9118 100/MI2 x 2 - 11 + 5 100A 816/2112 820/0A 9136 100/MI2 x 2 - 808/252 Multi tariff consumer units (100A double pole main switch control for each tariff) 4+1+4 100A 809/242124 815/0A 9414/M 100/MI2 x 3 - 8+1+5 100A 814/282125 820/0A 9815/M 100/MI2 x 3 - 7+1+6 100A 814/272126 820/0A 9716/M 100/MI2 x 3 - Split-load dual tariff consumer units (100A double pole main switch + 63A/80A double pole RCCB control for selected MCB ways.METAL CASED l The following selection tables enable easy identification of the components required to build a variety of consumer units. eg 808/232B. (100A double pole main switch control for storage heating MCBs) 814/282125 2+3+3 63A 30mA 808/22623 815/0A 9233/ST 100/MI2 x 2 363/S030 5+2+6 63A 30mA 813/25626 820/0A 9837/ST 100/MI2 x 2 363/S030 5+2+6 80A 30mA 813/25826 820/0A 9837/ST 100/MI2 x 2 380/S030 3+6+4 63A 30mA 813/23624 820/0A 9675/ST 100/MI2 x 2 363/S030 3+6+4 80A 30mA 813/23824 820/0A 9675/ST 100/MI2 x 2 380/S030 808/22623 Split-load dual RCCB consumer units (100A double pole main switch control for all MCB ways. 812/0AF. eg 813/A26786. 813/26786 S TA R B R E A K E R C O N S U M E R U N I T S E L E C T I O N G U I D E 3+2 97 . Factory-built consumer units are available to order – Add B to the consumer unit List No. (80A main switch RCCB control for selected MCB ways) 4+4 63A 100mA 80A 30mA 808/26484 815/0A 9355/ST 100/2MT 363/S100 380/030 4+4 80A 100mA 80A 30mA 808/28484 815/0A 9355/ST 100/2MT 380/S100 380/030 7+6 63A 100mA 80A 30mA 813/26786 820/0A 9387/ST 100/2MT 363/S100 380/030 7+6 80A 100mA 80A 30mA 813/28786 820/0A 9387/ST 100/2MT 380/S100 380/030 For flush mounting units up to 20 module – Add F to consumer unit and enclosure List No. Type A RCCBs are available – Add A to the consumer unit List No. eg 808/232F. The above RCCBs are Type AC. For 2 bank and dual RCCB consumer units. (80A double pole RCCB control for selected MCB ways) 98 817/26183 10 + 10 80A 30mA 820/283 824/2A 9120 x 2 100/2MT 380/030 7 + 10 63A 30mA 80A 30mA 817/26383 824/2A 9380/D 9120 100/2MT 363/S030 380/030 7 + 10 63A 100mA 80A 30mA 817/26183 824/2A 9380/D 9120 100/2MT 363/S100 380/030 13 + 13 80A 30mA 826/283 830/2A 9150 x 2 100/2MT 380/030 10 + 13 63A 30mA 80A 30mA 823/26383 830/2A 9311/D 9150 100/2MT 363/S030 380/030 10 + 13 63A 100mA 80A 30mA 823/26183 830/2A 9311/D 9150 100/2MT 363/S100 380/030 18 + 18 80A 30mA 836/283 840/2A 9200 x 2 100/2MT 380/030 15 + 18 63A 30mA 80A 30mA 833/26383 840/2A 9316/D 9200 100/2MT 363/S030 380/030 15 + 18 63A 100mA 80A 30mA 833/26183 840/2A 9316/D 9200 100/2MT 363/S100 380/030 Factory-built consumer units are available to order – Add B to the consumer unit List No. 80A double pole RCCB control for selected MCB ways) 3+7 80A 30mA 910/2383* 915/0* 9680 100/MI2 380/S030 4+6 80A 30mA 910/2483* 915/0* 9770 100/MI2 380/S030 5+5 80A 30mA 910/2583* 915/0* 9860 100/MI2 380/S030 6+4 80A 30mA 910/2683* 915/0* 9950 100/MI2 380/S030 3+7 80A 100mA 910/2381* 915/0* 9680 100/MI2 380/S100 4+6 80A 100mA 910/2481* 915/0* 9770 100/MI2 380/S100 5+5 80A 100mA 910/2581* 915/0* 9860 100/MI2 380/S100 6+4 80A 100mA 910/2681* 915/0* * Add M for Grey Metal front plate or W for White PVC front plate.METAL CASED l The following selection tables enable easy identification of the components required to build a variety of consumer units. 63A/80A double pole RCCB control for selected MCB ways. the Type A RCCB makes reference to the 30mA downstream device. SPINE BACKPLATE CONSUMER UNITS l = Available MCB ways Rating Consumer unit List No + + + Chassis Busbar Main incoming Split-load device RCCB 915/0* 9150 100/MI2 915/0* 9150 380/030 Main switch spine unit (100A double pole main switch control for all MCB ways) 13 100A 913/2* RCCB spine unit (Double pole RCCB control for all MCB ways) 910/2483 13 80A 30mA 913/383* Split-load spine units (100A double pole main switch control for all MCB ways. 9950 100/MI2 380/S100 . eg 820/283B. 2 BANK CONSUMER UNITS l + = Available MCB ways Rating Consumer unit List No Surface metal enclosure Busbar + + Main incoming device Split-load RCCB S TA R B R E A K E R C O N S U M E R U N I T S E L E C T I O N G U I D E (100A double pole main switch control for all MCB ways. RCCB + 5 410/2563B Main switch + 5. RCCB + 8 415/2763B Main switch + 8. RCCB + 7 810/2363B Main switch + 4. + = + + FLUSH Available MCB ways Rating Consumer unit List No Surface metal enclosure Busbar Main incoming device Split-load RCCB Main switch consumer units (100A double pole main switch control for all MCB ways) 7 100A 807/2F 809/0AF 9090 100/MI2 - 10 100A 810/2F 812/0AF 9120 100/MI2 - 13 100A 813/2F 815/0AF 9150 100/MI2 807/2F RCCB consumer units 7 40A 30mA 807/343F 809/0AF 9090 340/030 - 7 80A 30mA 807/383F 809/0AF 9090 380/030 - 10 40A 30mA 810/343F 812/0AF 9120 340/030 - 10 80A 30mA 810/383F 812/0AF 9120 380/030 - 13 80A 30mA 813/383F 815/0AF 9150 380/030 807/383F Split-load consumer units (100A double pole main switch control for all MCB ways. 80A 30mA RCCB + 5 410/2583B Main switch + 6. RCCB + 4 410/2663B Main switch + 6. RCCB + 6 410/2463B Main switch + 5. RCCB + 9 415/2663B Main switch + 7. 63A double pole RCCB control for selected MCB ways) 2+5 63A 30mA 807/2263F 812/0AF 9560 100/MI2 363/S030 3+4 63A 30mA 807/2363F 812/0AF 9650 100/MI2 363/S030 3+7 63A 30mA 810/2363F 815/0AF 9680 100/MI2 363/S030 4+6 63A 30mA 810/2463F 815/0AF 9770 100/MI2 363/S030 5+5 63A 30mA 810/2563F 815/0AF 9860 100/MI2 363/S030 6+4 63A 30mA 810/2663F 815/0AF 9950 100/MI2 363/S030 810/2363F BUILT-UP FACTORY ASSEMBLED ALL INSULATED Description List No 100A DP main switch + 13 MCB ways 413/2B Main switch + 4.METAL CASED l The following selection tables enable easy identification of the components required to build a variety of consumer units. Main switch and RCCB if applicable. busbar. RCCB + 6 810/2463B The above units come complete with appropriate enclosure. 810/2463B S TA R B R E A K E R C O N S U M E R U N I T S E L E C T I O N G U I D E (Double pole RCCB control for all MCB ways) 99 . RCCB + 7 415/2863B 410/2563B METAL CASED Description List No 100A DP main switch + 13 MCB ways 813/2B Main switch + 3. 100 301/CS DESCRIPTION ● CONTROL MODULES 3 Mod LIST No CIK22-20 CIK22-11 CIK22-02 CIK24-40 CIK24-31 CIK24-22 CIK24-04 CIK40-40 CIK40-31 CIK40-22 CIK40-04 CIK63-40 CIK63-31 CIK63-22 CIK63-04 Ventilation module 301/CS must be fitted every 2 contactors when mounting contactors side by side. Dimensions see page 132. Power reserve: 150hr – quartz timers.5 Mod 9mm Ventilation module ● 1 Mod l 443 MCBLD 943W 748 741 799 . SILENT OPERATION INSTALLATION CONTACTORS Pole Configuration N/O N/C 2 0 1 1 0 2 4 0 3 1 2 2 0 4 4 0 3 1 2 2 0 4 4 0 3 1 2 2 0 4 Description 20A Double Pole 24A Four Pole 40A Four Pole 63 A Four Pole CIK22-20 CIK24–31 CIK63–40 Auxiliary Contacts 1 2 4 Mod 1 0 CHHSLA11 CHHSLA20 l MODULES LIST No 6. TWILIGHT SWITCH l DESCRIPTION MODULES LIST No 2–2000 lux c/w sensor 3 ● ● 303/P2 Sensor to IP54. 303/P2 ACCESSORIES l Way blanking plate MCB Locking Device Way blanking plate for 915/0W Brass padlock and keys Insulating Grommet Barrel lock for metal cased enclosures For Technical details see page 120-121. 12V bell transformer 2 303/B12 With overload protection. BELL TRANSFORMER 303/B12 2 Mod 0. Control modules can be installed in Starbreaker enclosures either as part of the consumer unit or separately mounted. 8.CONTROL MODULES TIMESWITCHES 302/TD1 303/TS24 303/TQ7 301/S7 l l DESCRIPTION MODULES LIST No 1 channel 7 day/24hr digital 2 302/TD1 2 channel 7 day/24hr digital 2 302/TD2 24hr analogue synchronous 3 303/TS24 24hr analogue quartz 3 303/TQ24 7 day analogue quartz 3 303/TQ7 1–7 min staircase 1 301/S7 ● ● ● All timers have 16A resistive contact rating. Power reserve: 250hr – digital timers. Wide range of enclosures available for separately mounting RCCBs. secure protection against fire or shock risks caused by earth fault currents.RESIDUAL CURRENT DEVICES Crabtree RCDs comply fully with BS EN 61008 to Type A and Type AC classification. MCBs and RCBOs. Suitable for screw fixing or DIN rail mounting. TYPE A Pulsating dc (half wave rectified) waveform Pulsating dc (chopped) waveform TYPE AC Normal ac waveform Lifestar offers you the protection of Residual Current Devices (RCDs) for any industrial. L I F E S TA R R E S I D U A L C U R R E N T D E V I C E S Pulsating dc (chopped) waveform with a constant dc component 101 . RCDs rated from 13A to 100A are available in sensitivities from 10mA to 300mA providing safe. commercial or domestic application. 10mA tripping current 1 4416/A101 2 gang switched with neon indicator. RCD sockets are all passive control electromechanical operation and will not trip on loss of mains supply. 10mA tripping current 1 4416/A01_ _* 2 gang switched with neon indicator. Unique labyrinth switch design minimises visible arc flash and prevents front access to live parts. 30mA tripping current 1 4414/A103 2 gang switched with neon indicator. 3mm contact gap. Enables mounting in standard 25mm deep box (moulded variant). eg 4416/A03SC. 30mA tripping current 1 4416/A103 l 1 gang switched with neon indicator. 10mA tripping current 1 4416/A01BG 2 gang switched with neon indicator. 10mA tripping current 1 4406/A01 2 gang switched with neon indicator. 30mA tripping current 1 4426/A03BG l 1 gang switched with neon indicator. 30mA tripping current 1 4424/A03BG 2 gang switched with neon indicator. 10mA tripping current 1 4404/A01 1 gang switched with neon indicator. 10mA tripping current Dimensions 4426/A03BG 142mm x 82mm x 44mm For boxes less knockouts see page 68. Bronze . . 30mA tripping current 1 4404/A03 2 gang switched with neon indicator. 10mA tripping current 4416/A103 SURFACE METALCLAD PACK QTY 1 4424/A01BG 1 gang switched with neon indicator. enabling products to be precisely matched to specific applications. * Metal plate variants available in Satin Chrome .YR – Add suffix to List No. SB625 flush galv. Mechanical indication of contact position. 30mA tripping current 1 4416/A03_ _* Dimensions 146mm x 86mm Mounting boxes 9223/BG surface. 30mA tripping current 1 4414/A03BG 2 gang switched with neon indicator. 10mA tripping current 1 4426/A01_ _* 2 gang switched with neon indicator. 10mA tripping current 1 4424/A01_ _* 1 gang switched with neon indicator. or SB629 dry lining 4414/A01BG 102 All available with two earth terminals to enable installation to comply with section 607 (wiring regulations) Add suffix /TE to List No. Comply with BS 7288. 30mA tripping current 1 4416/A03BG l Dimensions 146mm x 86mm Mounting boxes 9223/BG surface. 10mA tripping current 1 4426/A01BG 2 gang switched with neon indicator. SB665 flush galv. ● ● ● ● ● ● ● ● ● Double pole operation. or SB629 dry lining L I F E S TA R S A F E T Y S O C K E T 4416/A03BZ INTERIOR PACK QTY 1 4414/A101 1 gang switched with neon indicator. 30mA tripping current 1 4424/A03_ _* 2 gang switched with neon indicator. MOULDED PACK QTY l 1 gang switched with neon indicator. 10mA tripping current 1 4414/A01_ _* 1 gang switched with neon indicator.BZ and Oyster Gold .SC. 30mA tripping current 1 4414/A03_ _* 2 gang switched with neon indicator. Trip free mechanism for automatic disconnection of supply. 10mA tripping current 1 4414/A01BG 1 gang switched with neon indicator. or SB629 dry lining 4406/A03 SURFACE METAL PLATE* l PACK QTY 1 gang switched with neon indicator. FLUSH METALCLAD PACK QTY 1 gang switched with neon indicator.13A SAFETY SOCKETS WITH RCD PROTECTION l The Lifestar safety socket is available in 1 and 2 gang versions with either 10mA or 30mA sensitivity. SB625 flush galv. 30mA tripping current 1 4406/A03 Dimensions 146mm x 86mm Mounting boxes 9048 surface. For further specification details of finishes see page 112. Interior units available for mounting into OEM equipment. 30mA tripping current 1 4426/A03_ _* Dimensions 142mm x 82mm x 44mm 4424/A01BZ FLUSH METAL PLATE* PACK QTY l 1 gang switched with neon indicator. Surface mounted units supplied with Birch Grey mounting box. All safety sockets incorporate pulsating dc fault current protection (Type A operation). L I F E S TA R R C D s SENSITIVITY Further technical information – see pages 116-117. ● ● ● BS 3871 and BS 4293. 10mm2 terminal capacity. Terminal capacities: – 50mm2. Type 1 classification (2.7–4In). TIME DELAY .RCCB l TYPE AC 221/100TD SENSITIVITY No OF POLES CURRENT RATING (A) MODULES 100mA 2 100 2 221/100TD - 4 100 4 241/100TD - 300mA 241/100TD RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION (RCBO) l 6132/030 side view CURRENT RATING (A) MODULES 10mA 30mA 6 2 6106/010 6106/030 10 2 6110/010 6110/030 16 2 6116/010 6116/030 20 2 6120/010 6120/030 32 2 6132/010 6132/030 40 2 6140/010 6140/030 CAUTION These devices are electronic units and should be disconnected from the supply during insulation and earth fault loop impedance testing. 103 . ● ● ● BS EN 61008. Type A rccb’s with 100mA sensitivity available on request. IEC 1008.RESIDUAL CURRENT CIRCUIT BREAKERS TYPE AC No OF POLES CURRENT RATING (A) MODULES 30mA DP 32 2 223/030 - 40 2 224/030 224/100 - 63 2 226/030 226/100 226/300 80 2 228/030 228/100 - 100 224/030 100mA 300mA - 2 221/030 221/100 221/300 TP & N 32 4 243/030 - - 40 4 244/030 244/100 244/300 63 4 246/030 246/100 246/300 100 4 241/030 241/100 241/300 228/030 TYPE A 224/100 l SENSITIVITY SENSITIVITY No OF POLES CURRENT RATING (A) MODULES 10mA 30mA DP 16 2 216/A010 - 32 2 223/A010 - 40 2 - 224/A030 63 2 - 226/A030 80 2 - 228/A030 100 2 - 221/A030 TP & N 40 4 - 244/A030 63 4 - 246/A030 100 4 - 241/A030 226/100 These units are not interchangeable with the RCCBs now available in the Starbreaker range illustrated on page 90. Features sealable cover. Note Max cable capacity 10mm2. Supplied with cut-out of 2 module size. All purpose enclosure (IP65) ● 744/3 ● ● ● ● CBE/3 Complete with DIN rail. Polycarbonate construction. Accessories available. 4 module CBE4/EK NEUTRAL TERMINAL 5 way. Complete with DIN rail and earth terminal. Features sealable cover and hinged protective cover. Complete with DIN rail and earth bar. Supplied with blank plate for converting to 3 module opening. Accessories available. 3 module CBE/BS CBE/EK CBE3/NK 7 way.MODULAR ENCLOSURES 3 MODULE l l DESCRIPTION LIST No General purpose enclosure (IP20) 744/3 ● ● ● ● Complete with DIN rail. 5 MODULE CBE/4 CBE/4 Suitable for all ratings. 3 module CBE3/EK 7 way. CBE/3 4 MODULE l DESCRIPTION LIST No General purpose enclosure (IP20) 744/4 ● ● ● Suitable for ratings up to 80A. Self-adhesive way label provided. Features sealable cover and hinged protective cover. All purpose enclosure (IP65) 744/4 ● ● ● ● ● ● L I F E S TA R E N C L O S U R E S ● ● l DESCRIPTION LIST No General purpose enclosure (IP20) EN100 844/4 ACCESSORIES FOR ALL PURPOSE ENCLOSURES l EARTH TERMINAL LIST No 5 way. Polycarbonate construction. Features sealable cover. For increased cable sizes use 4 module enclosure List No. Complete with DIN rail and earth bar. Complete with DIN rail. 104 844/4 Suitable for all ratings. Converts to 3 module by removing half blanks. General purpose enclosure (IP20) ● ● ● Suitable for ratings up to 100A. Self-adhesive way label provided. 4 module CBE4/NK Blanking strip CBE/BS External fixing bracket ME/FB Dimensions see page 131. Fabricated steel enclosure (IP20) ● 744/41 . Features sealable cover.CBE/4 (up to 25mm2). TECHNICAL DATA GENERAL International degree of protection WIRING ACCESSORIES page 106 page Terminal capacities 107 6A isolating switch 107 Seeklight 107 PIR sensors 108 Light & smoke detector 109 Communication 110 Datapak 111 Luminaire Support Couplers 111 Low Energy lampholders 112 Metal plate specifications 112 PVC Trunking 113 CIRCUIT PROTECTION page MCBs – general 114 MCBs – Starbreaker 115 RCDs – Starbreaker & Lifestar 116 RCBOs & RCDs – general 117 Starbreaker consumer unit applications 118–119 Control modules – general 120–121 TECHNICAL DATA 105 . IP RATINGS l The IP (International Protection) rating given to an enclosure states the degree of protection it offers by means of two digits. A summary of these is shown below; for a more detailed definition, see IEC 529: 1989, BS EN 60529: 1992. FIRST DIGIT SECOND DIGIT T E C H N I C A L D ATA I P R AT I N G S Protection against solid foreign objects and access to hazardous parts 106 l Protection against ingress of water The first digit covers protection against penetration by solid objects, which includes hands and tools such as screwdrivers. At the lowest of seven levels, 0, no protection is offered, either of the equipment itself from damage by intrusion or of a person contacting live or moving parts. At the highest, 6, there shall be no entry of dust. The second digit covers the degree of protection against the entry of water, on a progressive scale. For example, number 1 indicates that dripping water shall have no harmful effect, and number 6, that water projected in powerful jets against the enclosure from any direction shall have no harmful effects. IP IP 0 No protection 0 No protection 1 Protected against solid objects up to 50mm eg accidental touch by hands 1 Protected against vertically falling drops of water eg condensation 2 Protected against solid objects up to 12mm eg fingers 2 Protected against direct sprays of water up to 15° from the vertical 3 Protected against solid objects over 2.5mm eg tools and wires 3 Protected against sprays of water up to 60° from the vertical 4 Protected against solid objects over 1mm eg tools, wires and small wires 4 Protected against water splashed from all directions – limited ingress permitted 5 Protected against dust – limited ingress, no harmful deposits 5 Protected against low pressure jets of water from all directions – limited ingress permitted 6 Totally protected against dust 6 Protected against strong jets of water eg for use on ship decks – limited ingress permitted The letter X can be used in place of the first or second digit to indicate that tests have either not been made or are not applicable. N0TE In the event of additional holes being drilled/pierced or knockouts removed, suitable measures should be taken to restore the products to the original ratings. IEC 529, BS EN 60529 does not apply to protection against the risk of explosion or conditions such as humidity, corrosive gases, fungi or vermin. In certain cases equipment designed to be mounted in an enclosure will contribute towards the stated IP rating (eg pushbuttons mounted in an enclosure). Different parts of enclosures can have different degrees of protection and still conform to the standard (eg enclosures with pre-drilled conduit entry). l WIRING ACCESSORIES – GENERAL BRITISH STANDARDS l l An unqualified reference to the British Standards in this product catalogue indicates that the products referred to are marked with the British Standard and therefore comply in all respects with the standard stated. Where a qualification is given against the British Standard, eg BS 3676 where applicable, this means that there is no specific standard for the product in question and it has been tested as far as possible for compliance with the standard indicated. TERMINAL CAPACITIES (mm 2 ) Product 3 x 2.5mm2, 2 x 4mm2, 2 x 6mm2 13A Panel mounting socket 3 x 2.5mm2, 2 x 4mm2, 1 x 6mm2 10AX Capital / Platinum plate switches 10A Capital architrave switches 4 x 1mm2, 3 x 1.5mm2, 1 x 2.5mm2 20A Capital / Platinum DP switches 32A Capital / Platinum DP switches 3 x 2.5mm2, 2 x 4mm2, 1 x 6mm2, 1 x 10mm2 l LIST No.4009 For use on 200–250V 50Hz supply only. Not suitable for use with Capital architrave switches. One ‘Seeklight’ position is provided on each full size plate switch. l Quantity and gauge of cable accepted by terminals 13A Capital / Platinum socket outlets 13A Capital safety sockets 13A Capital / Platinum fused conn. units CAPITAL RANGE ‘SEEKLIGHT’ ASSEMBLY 1 Isolate mains before commencing work. 2 Connect neon wires to terminals, as shown in the following wiring 2 diagrams, to suit circuit conditions. 3 Locate neon indicator into position on back of switch plate (figure A). 4 Remove backing from self-adhesive pad and locate over neon to hold it in 4 place (figure B). General note The neon ‘Seeklight’ must be disconnected when carrying out insulation testing to avoid a false reading. Figure A Figure B CONNECTION TO VARIOUS CIRCUITS l One-way circuits 2 x 6mm2, 1 x 10mm2, 1 x 16mm2 50A Capital DP switches 45A Capital / Platinum cooker control units 2 x 6mm2, 1 x 10mm2, 1 x 16mm2 Capital / Platinum shaver supply unit Capital light/shaver unit 6A Capital ceiling switches 4 x 1mm2, 3 x 1.5mm2 16A Capital ceiling switches 2 x 2.5mm2 max 50A Capital ceiling switch 3 x 2.5mm2, 2 x 4mm2, 1 x 6mm2, 1 x 10mm2, N N L L L2 L1 N2 L2 N1 L1 Two-way circuits N Capital ceiling roses Capital safety batten lampholder 1.5mm2 multiway Capital safety pendant lampholder 1 x 1mm2 flexible cable 16A Minder PIR sensor 6 x 1mm2, 4 x 1.5mm2, 2 x 2.5mm2 L L2 L2 L1 6A TP ISOLATING SWITCH When installations incorporating electronic devices of the semi-conductor type are being tested, care must normally be taken to ensure that they are not subjected to the output voltage of an insulation tester. However, dimmer switches complying with BS 5518 (eg Crabtree 2190) will not be damaged by the application of a normal 500V insulation resistance test. In all other cases where electronic items are fitted, they should be disconnected whilst the insulation of the installation is tested. A notice, drawing attention to the fact that electronic devices are incorporated in the installation, should always be affixed at the intake position. This also applies to any neon indicators fitted. L3 L3 L2 L2 L3 L3 L2 L1 L2 L2 L3 L3 L4 L3 N L l LIST No. 4017, 4017/1, 6017/_ _ & 4587/BG Complies fully with requirements of BS EN 60947-3 for switch disconnectors. Rated SC making capacity 300A Rated conditional short circuit current 6kA (when protected by Starbreaker 6A mcb) Rated insulation voltage 300V Rated impulse withstand voltage 2.5kV Rated duty Uninterrupted Maximum switching rate 120 switch cycles per hour Rated short time withstand current 100A for 1 second Utilisation category AC 23B, 6A 250V 50Hz A POINT ON TESTING L1 L1 L1 Multiple control circuits N L L1 l L1 N L L2 L1 L2 L2 L3 L3 L4 L3 L1 L1 T E C H N I C A L D ATA W I R I N G A C C E S S O R I E S 32A Capital TP & N switches 45A Capital / Platinum DP switches 107 MINDER PASSIVE INFRA RED SENSORS l The Minder is a multi-adjustable, passive infrared movement detector. People and animals radiate heat, which is invisible to the human eye (infrared range). Consequently, the recorded infrared energy pattern changes when they enter the detection zone DETECTION RANGE DIAGRAMS 10 m 6.5 m 10 m ca. 22.5 m 16 m 6m 6m Minder 90 ca. 16 m 12 m Minder 220 Minder 280 P,L P,L N N 108 Connection Diagram Minder 280 TECHNICAL DATA l Horizontal range of detection 90˚ 220˚ 280˚ surveillance levels 4 4 4 Max. frontal range 12m 16m 16m Max. bilateral range 6m 16m 10m Switching segments 88 280 372 Water protection IP55 IP55 IP55 Switch off delay 2s-16min 2s-16min 2s-16min Dusk sensor, in Lux 5-1000 5-1000 5-1000 P Luminaire black N black/ white blue On-Off switch P Luminaire black N Minder black/ white blue T E C H N I C A L D ATA W I R I N G A C C E S S O R I E S Minder Connection Diagram (with On-Off Switch) INSTALLATION l The Minder functions optimally when installed lateral to walking direction. When selecting the installation site, ensure that: ● The minder is not covered by rigid or moveable objects (e.g. roofing elements, branches of tree, etc.). ● When unit is installed above, or lateral to luminaires, a minimum distance is always allowed between the unit and the luminaire, in order to prevent maloperation. ● when the unit is installed below luminaires, it is not heated up as a result of radiant heat from the luminaire. When mounted at a height of 2.5m, the detection range is as above mentioned, though deviations in the mounting height cause changes in the detection range. In the case of special conditions at the site (e.g. rows of trees, small plot of land, proximity to road, etc.) the enclosed masking strip can be used to restrict the detection range by sticking it on the Minder lens. MINDER FAULT FINDING ANALYSIS l NATURE OF FAULT REASON FOR FAULT REMEDY Minder does not operate Lens covered or dirty Check power supply, uncover and/or clean lens Inadvertent operation of Minder Hot air or smoke e.g. out of kitchens activate Minder Install Minder at a different location Lamp is permanently on Permanent movement in the monitored area Make sure that no heat source is in the detection zone and wait until adjusted time lapse has run down.. For control purposes, please cover the lens completely. Minder is bridged to manual operation by additional switch Switch to automatic operation A new and unique product comprising of an advanced ionisation type smoke detector and emergency light together with a signalling unit combined into a domestic ceiling rose. Dusk dawn feature prevents activation of the light when a power failure occurs during daylight hours. Activates room lights upon detection of smoke Emergency room light operational upon mains failure To provide an illuminated escape route. allowing safe convenient movement around your home. Failure to install this alarm correctly may expose the user to shock or fire hazards. Interconnect (White) No batteries required. tamper proof unit. maintenance free. Neutral (Blue) Replaces an existing ceiling rose. Switch Live (Brown) Once smoke has been detected the internal siren will activate and illuminate the room light attached to the pendant. White Unit Plug Conventional loop in/out Units Interconnected Live To next room Earth Live Live Earth Earth Neutral Neutral To next room Neutral Interconnect Fused lighting circuit from consumer unit Fused lighting circuit from consumer unit Switch Live Switch Live Room Light Switch Conventional loop in/out ceiling rose wiring diagram Room Light Switch Switch Live ROOM 1 ie Lounge ROOM 2 ie Hall Warning: This alarm is mains operated and should be installed in accordance with the published Regulations for Electrical Installations. The unit will stay in standby mode until power supply is resumed or when darkness falls. If the communication facility has been connected to other units. You must observe the installation procedures given in the installation instructions. it will then activate your emergency lighting. if mains power is unavailable . it is inconspicuous and aesthetically pleasing. If in doubt consult a qualified electrician. GENERAL INFORMATION l The sensing chamber is designed to detect smoke (not heat or flames). Power protection feature . Permanent Live (Red) This will act as an early warning signal and will illuminate your home to enable you and your family to escape in the event of a FIRE. Power supply monitoring system ensures 100% effectiveness. keeping you and your family safe Upon failure of your mains electricity supply either by power cut or fire. The emergency light incorporated in the unit will illuminate an average 3 metre square room for a period up to 2 hours.the unit still works via a rechargeable back up supply. No decoration disturbance. 109 . Test the unit at regular intervals (see Testing and Maintenance). Retro fit design (some disruption may be required for communication facility). No floor boards to lift. all the alarms will sound together and illuminate lamps attached to pendants in other rooms. fully sealed. T E C H N I C A L D ATA L I G H T A N D S M O K E D E T E C T O R This alarm will not prevent fire and is not a substitute for insurance. NB (b) All socket outlet connections are in parallel – any number of socket outlets can be connected. using Crabtree connection tool List No. formerly the 16th Edition of the IEE Wiring Regulations. 2 Plug connectors into 7268 in loft. 1 Fit a co-axial connector to the TV and FM aerial cables. 6 wire cable may be used. Connection tool Allow 50mm cable ‘tails’ at each connection block Connection block Push home in direction of arrow with connection tool 7265 – Single Direct connection outlet Excess cable may be trimmed using wire cutters T E C H N I C A L D ATA C O M M U N I C AT I O N S WIRING COLOUR CODE 110 Pin number Base colour/stripe 1 2 3 4 5 6 Green/White Blue/White Orange/White White/Orange White/Blue White/Green l In order to comply with the latest EMC directives.40–0. Approval is to BT Specification No. Each outlet is then wired separately to the amplifier. Connection of these telephone outlets is by the IDC (Insulation Displacement Connection) method allowing one or two equal size cables (0. l 1 2 3 Single connection outlet Domestic installation 6 5 4 TV As seen from rear WIRING DIAGRAMS l Amplifier Example of typical connections: 1 Connections to 2 & 5 2 Earth recall (when used) connect to terminal 4 3 Connection to terminal 3 is not usually required NB (a) Standard 4 wire cable is shown below as incoming cable. Suitable for use in accordance with BS7671. Testing (a) Connect cables as shown in wiring diagram (b) Plug in telephones (c) Lift receivers and check for dial tone (d) Make an incoming call to check bells work (e) If circuit does not work. FM Loft outlet FM aerial lead Co-axial down lead To TV To radio Living room outlet TV/FM outlet installation outlet . Co-axial outlet installation Communal aerial system eg flats. 3 Connect a co-axial cable run between back of 7268 in loft and back of 7268 in 7268 – Twin the living room. The products are similar in specification to units available from British Telecom. If terminals 1 and 6 (normally unused) are required. metal faceplate telephone socket outlets must be within the ‘equipotential zone’ of the building they are located in.6915 as shown below.68mm) to be terminated per connection block. TERMINATIONS l CO-AXIAL SOCKET OUTLETS Note If additional outlets are required. then plug TV and FM radio Isolated connection into front of plate. etc 1 2 3 1 2 3 4 5 6 4 5 6 1st socket outlet (Single master) Additional socket outlet(s) (Single secondary) WARNING NOTES In order to comply with current Wiring Regulations. all installations containing amplification systems or comprising multiple co-axial socket outlets must be fitted with appropriate earth bonding. Separate co-axial cable down lead to each outlet 7267 – Single Isolated connection outlet Existing incoming cable from PBX.50. Further information concerning the requirements of a telephone system installation can be obtained from the Department of Industry or the telephone equipment supplier. Therefore an earth terminal is fitted to metal plate units which should be connected to the electrical installation’s earthing system. but it is recommended that only a maximum of 5 telephones be used at any one time on one line. hotels etc TV TV aerial lead l TV and FM aerial connections use a twin connection outlet (7268) and one co-axial down lead. disconnect and check thoroughly before reconnecting Note Unauthorised connection of telephone socket outlets to wiring owned by British Telecom is an offence. an amplifier should be used.CAPITAL TELEPHONE SOCKET OUTLETS l The Crabtree Capital range of Telephone Socket Outlets has been developed primarily for use in telephone systems using British Telecom standards. TV All telephone outlets should be wired in accordance with the wiring diagrams shown below. screened TV module. splits signal back into 3 parts. However.IDC connector blocks Colour coding . DATAPAK TYPICAL USE OF PATCH PANELS. PIR security & EIBUS. BAND WIDTH/CAT DATA MODULES Cat 4 - 20Mhz RJ45 Cat 5e . PATCH LEADS & DATA OUTLETS 18" Rack mount Cabinet Phone System 1 2 3 4 5 l RJ45 Outlets Balun 6 TELEPHONE CAT 5e Cabling COMPUTER Balun Computer System 1 2 3 4 5 7 8 9 10 11 12 TELEPHONE COMPUTER 6 Balun TELEPHONE 7 8 9 10 11 12 TELECOM MODULES Master voice module . Ethernet) and CCTV installations. Typical 7 pin applications:- 5015 rear view 5013 rear view Technical details: Terminal capacity: 5x2.LUMINAIRE SUPPORT COUPLERS l 5 AND 7 PIN OUTLETS The 5 and 7 pin applications provide addition benefits when utilising building management systems included low voltage. 50mm x 50mm (double mod size) TV return . Each socket is screened. carrying combined signals. lightning protection.accepts BNC male plug.IDC connectors Capacitor. lightning protection. multiple sockets “daisy-chained” Cat 5 - 100Mhz ISDN Terminated (blue shutter) . resistor Accepts left handed plug MEDIA MODULES AND ACCESSORIES Triplex unit . dimmer.clasified as data outlet. 50 ohm or 70 ohm. no lightning protection.IDC connectors Master voice module (left handed) . 3x4mm2.TV/SAT/FM splitter. One cable in. emergency lighting circuits. (resistor optional) Secondary voice module .5mm2. used in conjunction with a distribution amplifier to distribute signals to other rooms BNC (female) . resistor PABX voice module . D ATA PA K COMPUTER 111 . in projects where refurbishment is being undertaken the LSC system is seen as an ideal cost effective solution where hard wiring may already be in place.BT 601 master IDC connectors (Krone style) Capacitor.RJ45 socket with 100 ohm resitor between pins 4 & 5 and one between pins 3 & 6 Ratio 8:1 use RJ11/12 .socket/cable/patch panel Tie wrap facility Use as socket on ISDN system. reducing susceptability to noise distortion thus improving picture reception. 1x6mm2 per outlet terminal Standards: BS7001 BS5733 general electrical requirements Note: BS 6972 only covers LSC’s rated upto 6A 250V Rating: Static load: max 10A 250V 5kg L1 A E LOOP L N A1 A2 Connection Maintained Auxiliary Live Earth Live Loop Live Neutral 0 to 10V 0 to 10V Description (Emergency Lighting) Building management systems Building management systems The LSC is forming an integral part of design installations for many major projects. as found on co-axial data systems (RG58. In new installations the specifier may choose LSCs to offer a versatile lighting system. but used as telecom socket in Eire & USA No capacitor accepts 6p6c plug (RJ12) and 6p4c plug (RJ11) Cat 5e - 160Mhz Cat 6 - 250Mhz T E C H N I C A L D ATA L S C .BT 601 master IDC connectors Capacitor. PB/WH . The Lampholder is designed to European standards and has a diameter of 42mm. when no lamp is present.Highly Polished Chrome with white moulded insert. or in the case of lamp failure at the end of lamp life. This reduces the power consumption. when compared to an equivalent incandescent lamp. Industrial Grey (BG) Base metal Steel Process 1 Iron phosphated 2 Epoxy polyester powder coated CFL COMPACT FLUORESCENT LAMPHOLDER l The design of the Lampholder accepts an industry standard 4 pin 10/13 Watt Compact Fluorescent G24 or lamp. by up to 80%.Satin Chrome with black moulded insert.WIRING ACCESSORIES – METAL PLATE SPECIFICATION T E C H N I C A L D ATA W I R I N G A C C E S S O R I E S & C F L CAPITAL 112 l PLATINUM LOW PROFILE Bronze (BZ) Base metal Brass Process 1 Linished and brushed 2 Electrophoretically lacquered 3 Stoved Satin Chrome (SC) Base metal Brass Oyster Gold (YR) Base metal Brass Process 1 Linished and brushed 2 Nickel plated 3 Electrophoretically lacquered 4 Stoved Polished Brass (PB) Base metal Brass Satin Chrome (SC) Base metal Brass Process 1 Linished and brushed 2 Nickel-chrome plated 2 and lanolin wiped Highly Polished Chrome (HPC) Base metal Brass Highly Polished Chrome (HPC) Base metal Brass Process 1 Polished plate 2 Electrophoretically laquered 3 Stoved Polished Brass (PB) Base metal Brass Process 1 Polished plate 2 Electrophoretically laquered 3 Stoved Rope Edge Brass (RB) Base metal Brass Process 1 Polish Plate 2 Electrophoretically laquered 3 Stoved Polished Stainless Steel (PSS) Base metal Stainless Steel Process 1 Polished plate 2 White interior as standard Black interior as standard Black interior as standard PLATINUM FLAT PLATE Stainless Steel (SS) Base metal Stainless Steel White interior as standard Polished Brass (PB) Base metal Brass Black interior as standard Polished Stainless Steel (PSS) Base metal Stainless Steel Black interior as standard Other finishes are available as made to order. HPC/WH . A Safety feature which protects the installation will disconnect the supply to the Lampholder:During a lamp change. This Safety feature is reset by switching the supply to the fitting off for 10 to 15 seconds. . which is larger than the typical Lampholder which is 29mm. SC .Polished Brass with white moulded insert. STRENGTH High impact resistant. 4) Should screening be required this can now be inserted into the relevant compartment.The Electrium group of companies is registered for assessed capability to ISO 9002 Part 1. The material is formulated to comply with BS4678 Part 4 (1982). For trunking each size of cable has been allocated a term. TABLE A5 CABLE FACTORS FOR TRUNKING Type of Conductor Conductor Cross .4 15. therefore. covers and bus-bar base sections are extruded. 3) For cutting it is recommended that a fine tooth tenon or hacksaw is used. 76 mm Min Accessory Boxes Drill hole of suitable size Term Value 1576 Square Top/Bottom section:Area 1507mm Term Value 682 Extended Bottom section:Area 3499mm Term Value 1583 All boxes are on the same plain. MANUFACTURE All trunking components are manufactured from PVCu material. Standard INSTALLATION RECOMMENDATIONS 1) The base section and extension base (if used) should be plug and screw fixed to the wall ensuring washers are used behind the screw head for a more secure fix.2 22.9 36. 5) Socket and data boxes can be positioned and wiring can begin. joint covers and accessory boxes are formed by injection moulding. the covers. 113 . Aromatics and Hydrocarbons should not be used on PVC trunking This Appendix is a method which can be used to determine the size of trunking necessary to accommodate cables of the same size. Temperature classification -5 to +60°C for permanent application range.0 10. T E C H N I C A L D ATA WA R W I C K P V C FINISH Manufactured in White Semi-gloss finish.5 2. stop ends.5 4. INSTALLATION TIPS Installation around columns. or different sizes. joint covers etc can be inserted.0 6.1 10. as has each trunking.3 Solid Bends. add together all the cable terms and compare against the trunking terms given in the following figures. 6) On completion of all wiring. Therefore. Angled Top/Bottom section:Area 1176mm Term Value 532 Central section:Area 3483mm 2) All joints should have a 5mm gap to allow for expansion and base section corners should be mitred. The number of cables drawn into or laid in an enclosure of a wiring system shall be such that no damage is caused to the cables or to the enclosure during their installation. holes should be drilled from top or bottom to accommodate data and telephone cabling. Area Term 1.Sect. corners. the following terms represent this in the internal area figures. DEGREE OF PROTECTION IP4X THERMAL PROPERTIES Water Absorbtion – Negligible Mineral Acids – Excellent Detergents – Excellent Note: Some solvents such as Ketones. The table refers to single core PVC Insulating cables only. Flat angles and tees are factory prefabricated from standard profiles. Base sections. To ascertain the size of trunking required. The cutting of the base sections is not critical as the manufactured fittings cover the joints and overlap the trunking lids. all power/data/telephone accessories can be wired and fixed.5 7. FIRE RESISTANCE The PVCu used in WARWICK trunking is non-propagating and complies with the requirements of BS476 parts 5 & 7 and BS4678 Part 4. The WARWICK range complies with all requirements of the 16th Edition of the IEE Regulations. Note: For power cables a space factor of 45% must apply. 138 mm Min STANDARDS Manufactured to comply with the requirements of BS4678: Part 4 (1982) and BSEN 50085-1 (1999).2 1. The Earth Loop Impedance Test can now be carried out. 7) Finally. Use a sharp knife or file for trimming. CABLE CAPACITIES The following table is from the 16th edition of the IEE Wiring Regulations: Guidance Note 1: Selection and Erection of equipment.0 8.5 2.1 11. 86 0.1 2 HRS 1 HR Adjacent thermal-magnetic MCBs should not be continuously loaded at or approaching their nominal rated currents when mounted in enclosures.60 0.78 1. specifies the maximum permissible earth fault loop impedance which is allowed using various protective devices.67 1.MCBs – GENERAL l Crabtree Starbreaker MCBs comply fully with BS EN 60898 and therefore enable the requirements of BS 7671 to be met.4 seconds and MCBs will operate in 0. AMBIENT TEMPERATURE CONSIDERATIONS BS RATINGS 5A 15A 20A 30A 45A Rewireable fuses BS 3036 10 House service fuse BS 1361 10. together with tables 41B1.0 At 0°C 1.07 Type C MCB BS EN 60898 4. which can be the result of contact with live parts. Type D MCBs are not quoted in BS 7671 since it is considered unlikely that the low earth loop impedances necessary can be achieved in practice. TYPE CLASSIFICATION l BS EN 60898 specifies different tripping characteristics for different types of MCB.4 1.9 At 20°C 1.38 1. MCBs can be used in conjunction with earthed equipotential bonding to achieve the required disconnection times of 0.8 0.2 0.89 5.6 1.4 1. 30°C Ref Calibration Temperature. This means that MCBs can be backed up by devices of greater capacity such as HRC fuses. EARTH FAULT LOOP IMPEDANCES (ZS) TO GIVE COMPLIANCE WITH BS 7671 REGULATION 413-02-08 AT 230V Maximum earth fault loop impedance in ohms for circuits supplying socket outlets (also fixed equipment in bathrooms) 114 l Regulation 432–02–01 of BS 7671 requires that a device providing protection against overload currents and fault currents shall be capable of breaking any overcurrent up to and including the prospective fault current at the point where the device is installed. INDIRECT SHOCK RISK PROTECTION l BS 7671.5 1.0 0. enabling installation designers to choose an MCB with a characteristic closely matched to the circuit requirement.14 0.01 0. depending on the level of overload current required to make the MCB trip out in less than 100 milliseconds. C or D.2 0.76 At these values of loop impedance fuses will operate within 0.2 0. the prospective fault current can be higher than the breaking capacity of the protective device if another protective device having the necessary breaking capacity is installed on the supply side. According to regulation 434–03–01.9 3. Crabtree MCBs are available as types B.1 second. we recommend a 66% diversity factor is applied to the MCB nominal rated current where it is intended to load the MCBs continuously (in excess of 1 hour).8 1.6 1.7–4In Domestic 2* – 4–7In Commercial 3* – 7–10In General Industrial * MCBs.48 0.85 1.8 3 2.1 Type B Type C Type D 0. At other temperatures the following rating factors should be used: At 60°C 0.2 0. Discrimination is said to occur when the device nearest the fault operates first. in industrial situations it could be even higher.6 3.001 1 3 5 10 20 100 1.4 seconds for 230V socket outlets and 5 seconds for circuits supplying fixed equipment (Regulation 413–02–08). 41B2 and 41D.62 Type B MCB BS RENARD SERIES OF RATINGS 6A 10A 16A 20A 32A 40A 50A 63A BS 88 8. consideration must be given to discrimination.96 0.000 RMS PROSPECTIVE CURRENT AS A MULTIPLE OF RATED CURRENT .4 1. type 1. formerly the IEE Wiring Regulations requires that measures are taken to protect against the risk of electric shock.53 HRC fuse l 2. Starbreaker MCBs are calibrated to meet the requirements of BS EN 60898. It is good engineering practice to apply generous de-rating factors or make provision for adequate free air between devices. This regulation.000 OPERATING TIME IN SECONDS T E C H N I C A L D ATA C I R C U I T P R O T E C T I O N FAULT LEVELS DEVICE 100 10 1. and in common with other manufacturers.43 1. In domestic situations this could be as high as 16kA. In these situations. When providing back-up protection.33 2.63 – Type B MCB BS EN 60898 8 4.09 0.75 0.82 1.85 1.6 BS EN 60898 9.2 & 3 to BS 3871 1.5 Type C MCB BS EN 60898 4 2.2 2. OPERATING CHARACTERISTICS FOR MCBs l MCB type BS EN 60898 type Instantaneous trip current range Typical application B B 3–5In Domestic C C 5–10In Commercial Light Industrial D D 10–20In General Industrial 1* – 2. DISCRIMINATION Healthy circuit current I 2 t ENERGY LET-THROUGH Starbreaker MCBs are calibrated to meet the requirements of BS EN 60898. Other ratings are available in Type C classification (5–10In). TERMINALS l The MCB terminals are designed to accept copper cable up to 16mm2 It is desirable that the protective device nearest the fault should operate first. 30°C Ref Calibration Temperature. gives a typical operating time of 3. Due to the method of connection onto the busbar it is not possible to use the 61/B06 range for custom built panels. The arc runs along the arc runner to the arc chamber where it is split up between the plates and extinguished.MCBs – STARBREAKER SPECIFICATION l 3 Establishment of arc between fixed and moving contacts As the moving contact moves away from the fixed contact. The total energy let-through depends on the value of current and the time for which it flows. The low energy let through of Starbreaker MCBs provides better discrimination with HRC fuse back-up than is given by earlier types of MCBs. Typical of this is the choice of silver graphite for the fixed contact.1 Adjacent thermal-magnetic MCBs should not be continuously loaded at or approaching their nominal rated currents when mounted in enclosures. damage can be sustained to the installation and associated equipment due to the amount of energy that passes before the current is completely interrupted. together with its accelerated extinction in the arc chamber.0 l At 0°C 1. an arc is established. Therefore the 610/06 range should be used (see page 91 for details). such as occur on domestic applications. having a compact construction which has been achieved by not only minimising the number of parts but also the number of welded joints and connections. 2 Short circuit conditions When the current flowing through the MCB reaches a predetermined level. In addition. Under fault conditions. The thermo-metal element moves against the trip bar releasing the trip mechanism. When providing back-up protection consideration must be given to discrimination between the MCB and fuse. GENERAL CONSTRUCTION PAGE 108 CURRENT LIMITING EFFECT Maximum prospective fault current l Starbreaker MCBs are of the thermal-magnetic current limiting type. The high speed current limiting action of Starbreaker MCBs ensures that the energy let-through and any subsequent damage is minimised. Critical material selection ensures reliability and durability.5–5 milliseconds.5kA (peak) 16kA when protected by 100A HRC fuse to BS 1361 3 T E C H N I C A L D ATA C I R C U I T P R O T E C T I O N AMBIENT TEMPERATURE CONSIDERATIONS l The high speed current limiting action ensures that the MCB operates before the full prospective fault current is allowed to develop. and in common with other manufacturers. the solenoid directly pulls in the plunger which forcibly separates the contacts and simultaneously releases the trip mechanism. At 20°C 1. 115 . The MCB has an easy to operate handle with a trip-free toggle mechanism – so even when the handle is held in the ‘on’ position the MCB is free to trip. METHOD OF OPERATION 20ms Prospective short circuit test current Back-up protection is required only if the prospective short circuit current at the point of installation exceeds the breaking capacity of the MCB. It is good engineering practice to apply generous derating factors or make provision for adequate free air between devices. a Type B MCB will give indirect shock risk protection at higher levels of earth loop impedance (see tables on page 114). Starbreaker main switch ● Specification ● Rating ● Utilisation category ● Type ● Insulation voltage ● Impulse withstand voltage ● Rated duty ● Short-time withstand current ● Short-circuit making capacity ● Conditional short-circuit current ● Pollution degree 100/MI2 BS EN 60947-3 100A 230V 50Hz AC-22A Double pole switch disconnector 250V 4kV Continuous 2kA for 1 second 3. BACK-UP PROTECTION 20ms l Typical values of I2t energy let-through for Starbreaker MCBs are given in the table below: MCB rating Total I 2t let-through (A) (A2 sec) MCB rating Total I 2t let-through (A) (A2 sec) 6 7500 20 23500 10 13000 32 33000 16 21500 40 40000 6000A MOUNTING THE MCB l l l In Crabtree consumer units Starbreaker MCBs are mounted on standard 35mm top hat rail to BS 5584: 1978 EN 50022 giving a projection within the Standard of 70mm. At other temperatures the following rating factors should be used: At 60°C 0. The rapid development of the arc. we recommend a 66% diversity factor is applied to the MCB nominal rated current where it is intended to load the MCBs continuously (in excess of 1 hour). This reduced energy let-through assists greatly with both back-up and discrimination considerations. The low inertia and consequent high speed of the moving contact has a limiting effect on the flow of fault current. and is denoted by the symbol I2t. In these situations. l British Standard BS EN 60898 Short circuit breaking capacity 6000A (M6) ● Type classification B (3–5In) ● Rated voltage 230V ● Rated frequency 50Hz ● ● CURRENT LIMITING ACTION APPLICATIONS l The Starbreaker single pole MCB with its Type B characteristics is suited for use on loads with little or no switching surges.9 l Fault l 1 Moderate overload conditions Detection of moderate overload conditions is achieved by the use of a thermo-metal element which deflects in response to the current passing through it. If they are the only means of earth fault protection. To comply with Regulation 413-02-16 the earth fault loop impedance in ohms multiplied by the rated tripping current of the RCD in amperes must not exceed 50. 1/2 3/4 5/6 N Tripping Device Test button (interlocked) Current balance transformer Test resistor Note Exposed installation metal work must be earthed. it is possible for sufficient earth fault current to flow undetected to constitute a fire risk. is prevented. 300mA provide the means to achieve compliance with BS 7671 in conditions of poor earth loop impedance and also give a good level of fire risk protection. an amount of current will flow to earth. Overcurrent protection devices cannot detect earth fault currents below their operating current. l l . Regulation 471-16-02 also contains a requirement for circuits supplying portable equipment outdoors supplied other than through a socket outlet. 4 and 5 module RCCBs or an electronic relay in the case of Starbreaker. against fire or shock risks caused by earth leakage currents. accidental damage or failure of electrical appliances. 10mA provide a higher level of personal protection. SENSITIVITIES N RCD circuit diagram (four pole) Note Exposed installation metal work must be earthed. the flow of the sustained earth fault current. It is recommended that an RCD is tested at least quarterly. the current in the phase conductor is equal to the current in the neutral and the vector sum of the current is zero. a high sensitivity RCD to a Type A classification with a maximum tripping current of 30mA should be used. Regulation 471-16-01 of BS 7671 indicates that where a socket outlet may reasonably be expected to supply equipment to be used outside the zone. schools and workshops where potential hazards exist from electrical faults caused through misuse. 1/2 3/4 Tripping Device Test button (interlocked) Current balance transformer Test resistor Fault sensing winding 2/1 4/3 RCD circuit diagram (two pole) TRANSIENT EARTH LEAKAGE CURRENTS TEST BUTTON All Crabtree residual current devices incorporate a high level of immunity to tripping when subjected to transient earth leakage currents. Fault sensing winding 2/1 4/3 6/5 (b) to provide a higher level of protection than that given by direct earthing. With the RCD having a sensitivity of 30mA. Under healthy circuit conditions. Single phase and neutral or three phase and neutral units (suitable for 3 or 4 wire systems) are available. the maximum permissible earth fault loop impedance is calculated as follows: ZS (max)=50/0. A test button is provided on all RCDs to enable the operation of the device to be checked. In the event of an earth fault. Lifestar and Lifestar SRCDs. l The choice of RCD depends upon the application of the level of protection required. formerly the IEE Wiring Regulations. protection shall be afforded by a residual current device having a rated residual operating current not exceeding 30mA. 30mA for use where a higher level of protection is required. they will continue to provide a higher level of protection than would have been given by direct earthing. The secondary winding of the current transformer is then connected to the trip mechanism. The shock risk associated with these earth fault currents is also greatly reduced. The RCD trip mechanism will operate at a residual current of between 50–100% of its rating tripping current (sensitivity). Even if earthing conditions deteriorate substantially.5mm2 3 x 4mm2 2 x 6mm2 Starbreaker RCBOs 10mm2 APPLICATIONS l Residual Current Devices (RCDs) may be required for one of two main reasons: (a) to ensure the compliance of an installation with BS 7671. either an electromagnetic relay in the case of 3. Crabtree RCDs are therefore less susceptible to nuisance tripping due to transient earth leakage currents. They are unaffected by parallel earth paths and are thus ideally suitable for the protection of installations in modern high density dwellings or office blocks.03=1666 Ohms Other voltage ratings available on request OPERATION 116 TERMINAL CAPACITIES Rated tripping current of RCD Max permissible earth fault loop impedance 30mA 100mA 300mA 1666 Ohms 500 Ohms 166 Ohms l The RCD employs the current balance principle which involves the supply conductors to the load (phase and neutral) being wound onto a common transformer core to form the primary windings. By using an RCD. This out of balance is detected by the secondary winding of the transformer and at a pre-determined level of out of balance will activate the trip mechanism. This is particularly important with portable appliances where there is a danger of losing earth continuity due to damage or fatigue. Such transients can occur when there is a significant level of capacitance to earth as can result from cable capacitance (particularly MICC) or RF filter networks. Residual current devices are completely selective in their operation. 100mA provide the means to achieve compliance with BS 7671. (See BS 7671 Regulation 514-12-02). An RCD may be installed to meet the requirements of Regulation 413-02-15 where a high earth fault loop impedance disqualifies the use of overcurrent protection devices as a means of providing protection against indirect contact. They are virtually tamperproof and provide a predetermined level of protection. creating an out of balance situation in the transformer assembly. To provide complete personnel protection. a high level of fire risk protection and a degree of indirect shock risk protection. Starbreaker 100A plug in rcd’s are recommended for use in larger capacity enclosures. the latter being suitable for balanced or unbalanced 3 phase loads. above the tripping current of the RCD.RCDs – STARBREAKER & LIFESTAR l SPECIFICATION l BS EN 61008 RCCBs ● BS EN 61009 RCBOs ● BS 7288 SRCDs ● Range of current ratings ● Range of sensitivities ● Pole configurations Lifestar RCCBs ● 13–100A 10–300mA DP and TP & N DP SRCD – 230V ● Voltage ratings 3 & 4 Module DP – 230V 4 Module TP & N – 400V 5 Module TP & N – 400V ● Frequency rating 50Hz ● Tripping principle employed Electro-mechanical T E C H N I C A L D ATA C I R C U I T P R O T E C T I O N 50mm2 l Lifestar SRCDs 3 x 2. for use in sensitive areas such as laboratories. When used on 3 wire 230V systems a link should be connected between L and N. for further advice consult our Technical Department. with portable equipment or equipment used in hazardous conditions. The MCB element of the Starbreaker unit has a Type B (3–5In) classification making the device more suitable for domestic or light commercial applications. along with extensive use in computers. pathyphysiological effects such as cardiac arrest. 3 Usually no organic damage to be expected.000 10. breathing arrest and heavy burns may occur. New International standards IEC 1008 (RCCBs) and IEC 1009 (RCBOs) divide RCDs into two performance classes: Type AC RCDs for which tripping is ensured for residual sinusoidal alternating currents. Likelihood of muscular contraction and difficulty of breathing.000 5. All RCBOs give a high level of protection to individual circuits whilst exhibiting improved immunity to response caused by transients. In some cases the waveform may be rectified or chopped. probability of ventricular fibrillation increased up to 5% (Curve C2) up to 50% (Curve C3) and above 50% beyond Curve C3.2 0. T E C H N I C A L D ATA C I R C U I T P R O T E C T I O N As Starbreaker RCBOs employ electronic components they should be disconnected when carrying out the following tests on the electrical installation: (a) Earth fault loop impedance test The load terminals should be disconnected if it is intended to parallel-out the unit for test purposes. INSTALLATION TESTING – CAUTION FAULT CURRENT SENSITIVITY l Semi-conductor devices are now incorporated in equipment used throughout industry. whether suddenly applied or slowly arising. check for the following symbols: TYPE AC normal ac sensitivity l TYPE A pulsating dc sensitivity Crabtree RCDs are available as both Type AC and Type A devices. whether suddenly applied or slowly arising. As the equipment is fed from the mains electrical supply. and transient cardiac arrest without ventricular fibrillation increases with current magnitude and time. 5. 117 . VDUs. Typically.3 0.RCBOs (MCB/RCDs) & RCDs – GENERAL l SPECIFICATION l STARBREAKER RCBOs (MCB/RCD) ● Standard ● Short circuit breaking capacity ● Current rating ● Type classification ● Sensitivities ● Rated voltage ● Rated frequency ● Tripping principle employed ● Pole configurations BS EN 61009 6000A (M6) 6–50A B 10mA & 30mA 230V 50Hz Electronic Single pole with solid neutral LIFESTAR RCBOs comply with BS 3871/4293. the purpose of these semiconductor devices is for monitoring and controlling industrial equipment eg speed controls for small motors and temperature controls. For this reason it is recommended that the device is disconnected during this test. Lifestar RCBOs are for use on Starbreaker consumer units pre July 1992 and are also suitable for separate sale enclosure mounting.000 Typical current Limits due to body resistance at 230V 4 In addition to the effects of zone 3.5 1 2 3 5 10 Current in milliamperes (RMS) 30mA 100mA 20 30 50 100 200 300 500 1.1 0. These waveforms are said to contain a pulsating dc component which can either partially desensitise or totally disable a standard Type AC RCD.000 b c1 c2 IEC 479 c3 1 Usually no reaction effects.000 Time in milliseconds 2000 1000 500 1 2 3 4 200 100 50 20 10 0. To ensure the correct level of protection. etc. in the event of an earth fault the presence of semi-conductors may result in the normal ac waveform being replaced by a non-sinusoidal fault current. Increasing with magnitude and time.000 3. It may incur damage if mains potential is maintained on the load terminals of this unit after the trip mechanism has operated. commerce and in the home. Type A RCDs for which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents. RCBOs with other MCB classifications are available to order. APPLICATIONS l RCBOs provide both earth fault and overcurrent protection. 2 Usually no harmful physiological effects. washing machines. IEC PUBLICATION (479) CURVES WITH CRABTREE RCD CHARACTERISTICS SUPERIMPOSED l TIME/CURRENT ZONES OF EFFECTS OF AC CURRENT (15–100Hz) ON PERSONS Zone Physiological effects a 10. printers. false readings may be given on the test instrument.000 2. (b) Insulation test Whilst RCBOs can withstand the effects of normal insulation testers without damage. reversible disturbances of formation and conduction of impulses in the heart. To assist product selection we have included references of the components required in order to assemble the particular variant. Supply diagram Internal wiring diagram N MAIN SWITCH HEATING CONTROL METER N MAIN SWITCH STANDARD METER N L N MAIN SWITCH L MAIN SWITCH N N SERVICE CUT OUT FUSE 100A INCOMING SUPPLY SPLIT-LOAD DUAL-TARIFF l Combining the added safety of a split-load RCCB and the economy heating tariff into one combined unit offers an all-round saving of space and installation time. however the enclosure is not fitted with three neutral bars. In this instance the bottom immersion heater neutral should be connected directly to the bottom neutral terminal on the appropriate main switch.STARBREAKER CONSUMER UNIT APPLICATIONS l The following information illustrates the methods by which consumer units can be installed into more specific applications. TWIN-TARIFF l Twin-tariff combines two independent supplies typically the standard domestic supply and the supply for storage heaters. This installation can be housed within one standard enclosure thus saving space and installation time. T E C H N I C A L D ATA C I R C U I T P R O T E C T I O N Supply diagram 118 Internal wiring diagram N HEATING CONTROL METER MAIN SWITCH SPLIT LOAD RCCB N N MAIN SWITCH N STANDARD METER L N N MAIN SWITCH L MAIN SWITCH SPLIT LOAD RCCB N N N SERVICE CUT OUT FUSE 100A INCOMING SUPPLY MULTI-TARIFF l Multi-tariff heating provides 3 tariffs catering for total heating applications: 1 Direct heating appliances 2 Bottom immersion heater 3 Storage heating Supply diagram Internal wiring diagram RADIO TELESWITCH N N N TO STANDARD CONSUMER UNIT STANDARD METER HEATING CONTROL METER MAIN SWITCH MAIN SWITCH MAIN SWITCH N L MAIN SWITCH 1 2 N L MAIN SWITCH N L MAIN SWITCH 3 N N N SERVICE CUT OUT FUSE 100A INCOMING SUPPLY NOTE 15 module enclosures will accommodate this facility. for example multi-tariff or dual RCCB consumer units. . or 33 way Dual RCCB 17. 23. 26. Furthermore each RCCB will operate totally independent from each other. 23. or 33 way Split-load Bottom bank is fed via the direct connection unit 100/DC2 N N N N N N L L N N MAIN SWITCH L SPLIT LOAD RCCB N MAIN SWITCH SPLIT LOAD RCCB N L RCCB N N N N N N L L N 20. Continuity of supply between the top and bottom banks (where required) can be achieved by utilising the main switch with the additional terminal.STARBREAKER CONSUMER UNIT APPLICATIONS l DUAL RCCB l This type of configuration combines the benefit of both100mA RCCB protection for lighting and 30mA RCCB protection for personal safety. Internal wiring diagram N N N N L N MAIN SWITCH N SPLIT LOAD RCCB L N L RCCB N N TWO BANK l Two bank consumer units provide the facility to offer a wide range of configurations for applications which demand increased numbers of circuits. Supply and internal wiring diagrams N N N L N N MAIN SWITCH N N N N L N MAIN SWITCH L N MAIN SWITCH SPLIT LOAD RCCB SPLIT LOAD RCCB N L N N N N N L N N N N L N RCCB N N 17. The main switch provides total isolation of the entire consumer unit. 10 or 15 way Split-load Bottom bank 6. 9 or 14 way Multi-tariff N N L N L MAIN SWITCH MAIN SWITCH N N N N Top bank 8 or 13 way Dual RCCB Bottom bank 9 or 14 way Multi-tariff MAIN SWITCH N MAIN SWITCH N T E C H N I C A L D ATA C I R C U I T P R O T E C T I O N N N 119 . or 36 way Split-load N N RCCB N N N L N N N N L MAIN SWITCH N L MAIN SWITCH N L N N L Top bank 7. It is necessary to use the main incoming device fitted with the additional terminal to provide the independent supply to the second RCCB. Changeover contacts. This does not affect the time-keeping or switching functions of the device. Manual override. P 3 N 4 Switch with neon MCB 16A max Staircase 4 wire Typical wiring diagram SENSOR M 1 2 3 L N LOAD Twilight switch Typical wiring diagram L N 4 5 . reswitchable lighting.5VA Holiday programme 1– 45 days 1– 47 days Standard VDE0875 VDE0875 Memory locations 42 24 Every day programme switchings per week 294 168 Permissible ambient temperature -10–+50°C -10–+45°C ● ● ● L Permanent ‘on/off’. or use additional insulation (sleeving etc) to provide appropriate insulation. Override switch for permanent ‘on’. TWILIGHT SWITCH MCB 6A L1 It is important to note that when this unit is installed with other 240 or 415V equipment. ● Glow lamp max 50mA. l LIST Nos 302/TD1 1 Channel 302/TD2 2 Switching programme 24hr/7 day 24hr/7 day Power reserve 250hr 250hr Minimum setting 1 min 1 min Contact rating resistive at 240V ac 16A 2 x 16A Accuracy at 20°C ±1 sec/day ±1 sec/day Power consumption 8. reswitchable lighting. temporary fading of the display may occur.5VA 8. L1 (P) N l Operating voltage 190–240V Mains frequency 45–60Hz Power consumption 2. 2000W fluorescent ● 3 L N Daily and weekly programmes. ● 4 MCB 16A max Synchronous motor. ensure secondary connections use cable with insulation rated for 240/415V duty. Connection of additional timing device will provide facility to override ‘switch on’ status. In the event that the ambient temperature exceeds those stated above. Power: 5VA. Manual override. Secondary 4/8/12V. ● Clear switch position indicator. OFF 2 1 LOAD Operating voltage 190–240V Mains frequency M ON M 2 1 If the timers are used in combination with other devices within a system it is important to check that the entire system does not cause adverse interference. ● Selector switch for adjustment of ranges: range 1 2–35 lux. Untimed. Normal lighting Retractive switches Timed lights 4 l 16/240 2000W 2000W Operating voltage: Primary 240V 50/60Hz. BELL TRANSFORMER MCB 16A max Digital 1 channel Typical wiring diagram MCB 16A max Switching capacity 16A resistive.CONTROL MODULES – GENERAL ANALOGUE TIME SWITCHES 303/TQ7 7 day – 150hr 150hr Setting interval 15 min 15 min 1hr Minimum switching 30 min 45 min 4hr Contact rating at 240V ac 16A 16A 16A ● Changeover contacts. 2000W tungsten. ● ● 3 8 MCB 6A max MCB 16A max LOAD L Analogue Typical wiring diagram ● C1 1 C2 2 3 ● ● 5 MCB 16A max LOAD LOAD M 6 L N MCB 6A N Digital 2 channel Typical wiring diagram Retractive switches Timed lights 3 l P 3 N 4 Switch with neon L1 (P) N Staircase 3 wire Typical wiring diagram 4-lead rising mains Timed. ● Pre-selector switch for 3-4 wire connection. STAIRCASE TIME SWITCH N 7 N DIGITAL TIME SWITCHES T E C H N I C A L D ATA C O N T R O L M O D U L E S 303/TQ24 24hr Power reserve ● 120 l LIST Nos 303/TS24 24hr Time period l ● Delay ‘on/off’ eliminates nuisance switching. standard lighting switches. range 2 35–2000 lux. Summer/Winter time changes. 50–60Hz Connection: 3-lead rising mains Timed. ● Short circuit resistance is in accordance with IEC 742. ● Time range 1–7 minutes.2VA Contact rating resistive @ 240V 10A Incandescent lamp load 1000W Brightness range 2–2000 lux Switching delay (on/off) 80 seconds approx Switching status indication LED (no delay) Connection cable for light sensor 2 core cable max length 100m Permissible ambient temp -10 to +50°C control -40 to +70°C unit control light Protection category IP20 unit IP54 sensor ● Can be wired normally open or closed. l TYPE Thermal Rating per Pole AC1(A) CIK22 20 1.5 11 4 3 2 0 0 1 2 4 CIK40-40 CIK40-31 CIK40-22 CIK40-04 CIK63 63 8.2 4 4 3 2 0 0 1 2 4 CIK24-40 CIK24-31 CIK24-22 CIK24-04 CIK40 40 5. Suitable for heating.operation CIK24 25 15 7 3 1 15 15 15 10 5 3 2 1 6 6 4 3 3 12 10 7 5 3 2 – 1 1 1 – – 3 3 2 1 1 – – 24 20 13 8 8 5 2 x 48 2 x 24 2 x 15 30 16 12 32 16 10 CIK40 65 40 20 8 4 100 100 100 70 15 10 6 3 13 13 9 6 6 24 20 16 10 6 4 2 10 10 8 4 4 22 18 18 10 6 4 2 90 65 40 45 45 25 2 x 100 2 x 65 2 x 40 60 30 22 40 20 10 CIK63 85 50 25 10 5 150 150 150 70 20 13 8 4 20 20 14 9 9 38 30 25 16 10 6 3 16 16 12 7 7 33 27 27 16 9 7 3 140 95 60 70 70 43 2 x 150 2 x 95 2 x 60 80 42 30 48 26 18 T E C H N I C A L D ATA C O N T R O L M O D U L E S Halogen lamps 60W 100W 200W 500W 1000W 7W 11W 15W 20W 200W 300W 500W 1000W 35W 55W 90W 135W 180W 50W 70W 110W 150W 250W 400W 1000W 35W 55W 90W 135W 180W 50W 70W 110W 150W 250W 400W 1000W 18W 36W 58W 18W 36W 58W 18W 36W 58W 1 x 18W 1 x 36W 1 x 58W 2 x 18W 2 x 36W 2 x 58W CIK22 21 13 7 3 1 10 10 5 3 – – – – 5 5 3 2 3 12 10 8 6 3 2 1 1 1 – – – 3 2 2 1 – – – 24 17 10 6 6 4 2 x 22 2 x 17 2 x 10 22 12 8 23 12 7 Dimensions – see page 132 121 . air conditioning. lighting.3 (N / 0 only) – 2 1 0 0 1 2 CIK22-20 CIK22-11 CIK22-02 CIK24 24 2.5 15 4 3 2 0 0 1 2 4 CIK63-40 CIK63-31 CIK63-22 CIK63-04 230V Auxiliary Contacts Motor Rating AC3 (kW) 230V 400V Pole Configuration N/O N/C LIST No 400V AC15 6 4 – – 1 2 1 0 CHHSLA11 CHHSLA20 MAXIMUM NUMBER OF LAMPS PER POLE TYPE Incandescent lamps Energy saving lamps Low pressure sodium-vapour lamps (uncompensated) High pressure sodium-vapour lamps (uncompensated) Low pressure sodium-vapour lamps (compensated) High pressure sodium-vapour lamps (compensated) Fluorescent lamps (uncompensated) Fluorescent lamps (compensated) Fluorescent lamps (dual fitted) Fluorescent lamps with electronic starting device AC . motors and similar equipment.SILENT OPERATION INSTALLATION CONTACTORS These DIN rail mounted contactors with silent operation are ideal for mounting in consumer units destined for either residential or commercial dwellings where quiet running is a priority. DIMENSIONS page WIRING ACCESSORIES PVC TRUNKING CIRCUIT PROTECTION 122 123-126 127 128-132 . 7 14.3 22.7 19.8 16.3 23.0 17.4 10.0 38. These dimensions are a guideline only.3 50.5 A countersunk screws.5 * Fixing holes drill to accept 4mm countersunk screws.6 66.4 16.3 48.3 48.6 29.3 23.0 10.4 14.2 5. A F F R1.3 48.8 16.4 5.8 38.8 14.6 84.6 P C 4522/13 120.0 17.0 38.2 38.6mm.3 – – – – – – – – R1.5mm countersunk screws.9 23.7 40.6 25.5 7259 A R0.6mm (except 7259 – 2.4 7.3 20. panel thickness 1.0 38.0 14. more detailed drawings are available upon request.3 16. List No 8265/1 *A* B C 60.8 38.6mm.0 29.9 38. General tolerance ±0.6 19.3 38. F G D E CL *A* B C D E F G H J K A L M N L P R S J D R1.0 14.9 – – – – l N 4316/13 120.7 R1.0 40.0 38.3 19.7mm.3 41 30 * Fixing holes drill to accept 4mm B C C D A R1. Max.4 10.0 H DIMENSIONS WIRING ACCESSORIES CAPITAL 45A DP ‘SLIMLINE’ COOKER CONTROL UNIT INTERIORS l List No R0.6mm.4 – – – – l N 60.6 10.0 10.5 41.7 28.4 5.7 Q Max panel thickness 1.0 29.6 30.8 38.7 14.4 30.8 14.8 14.7 l K R CL H J S R0. panel thickness 1.13mm. R0.0 17.6 30. G B H 4314/1 & 4314/13 R1. CAPITAL 13A FUSED CONNECTION UNIT INTERIORS List No *A* B C D E F G H J K 4831/1 60.2 38.4 – – – – – – A L B J M D H K – * Fixing holes drill to accept 4mm countersunk screws.6mm.1 16.6 10.8 16.2 14.6 30.0 15.4 16.0 38.8 14.5 Max panel thickness 1.7 E L K D J * Fixing holes drill to accept 4mm countersunk screws.3 12.0 – – – – – – – 4832/13 60.6 21.5 8257/1 120.0 All dimensions in mm.8 38. CAPITAL TELEPHONE & CO-AXIAL OUTLETS List No *A* B C D 8283/1 60.3 22.0 List No R1.0 M C CL P J 4314/13 60.8 38.75 E R * Fixing holes drill to accept 3.4 7.6 19.0 R1.2 38.5 16.3 16.0 29.7 40.5 B A E B C D 7259 8255/1 CAPITAL 13A TWIN SOCKET OUTLET INTERIORS List No *A* B C D E F G H J K L M N 4316/1 120. 8283/1 & 8284/1 8265/1 & 8266/1 R3.3 20.6 84.6 10. Max.5mm * countersunk screws.0 – – – – F 4837/1 60.0 40.2 17.2 38.0 – – – – – – – 4832/1 60.5 4836/1 60. C Max panel thickness 1.4 94.4 28.6 10.6 29.4 24.5 10.7 A B G C D 23.0 15.8 38.6 K F T T N D 4522/13 21.7 28.9 38. Max panel thickness 1.5mm).2 8284/1 60.0 38. 123 .6 21.3 21 30 B l 8266/1 60.2 5.4 16.4 30.3 48.3 38.2 14.2 * Fixing holes drill to accept 3.2 17.PANEL CUT-OUT DETAILS l CAPITAL 13A SINGLE SOCKET OUTLET INTERIORS List No *A* B C D E F G H J K L M N P 4314/1 60.3 12.7 R2.4 23.2 38.0 – – – R0.0 23.6 30.0 14.4 24.2 38.4 28.5 41.0 – – – – – – – – – – – – 8255/1 60.0 Q M G B 4522/1 120.0 F E 4837/13 60.0 – – – – R0. 6 D E A F A l F E B R0.1 30.7 21. more detailed drawings are available upon request.3 49.3 38. A CAPITAL 2A ROUND PIN SOCKET OUTLETS 60.9 Dia 12.5mm countersunk screws.3 25. Dimensions A B 6552/_ _ – 2 gang * Fixing holes drill to accept 3.0 B R1.PANEL CUT-OUT DETAILS l CAPITAL 10AX/20A/32A SWITCH INTERIORS List No *A* B All 1 gang 60.5 16.6mm.3 38.6 23.9 l 7.4 3 holes 15.7 30.08mm dia at 90° (for 6BA screw) and alternatively tap 6BA C D A .6 4011/1 & 4012/1 60. second fixing hole facilitates panel mounting if required.6 C 6172/1 60.1 5. 124 14.9 Dia 24.6 * Fixing holes drill to accept 3.0 19.6 List No 2272/1 * Fixing holes drill to accept 3. 6172/1 & 6173/1 4011/1 & 4012/1 4011/13 & 4012/13 Max panel thickness 2. 2. 14.4 Dia 20.5 * Fixing holes drill to accept 3.6 CAPITAL 15A ROUND PIN SOCKET OUTLETS 30. 12.1 Dia 9. ROCKERGRID PANEL CUT OUT DETAILS 60.6 Max panel thickness 1.6mm.048mm dia countersunk to 5.3 ROCKERGRID TOGGLE SWITCH PLATES A List No 6551/_ _ – 1 gang A A B 16.3 CL l List No 8075/1 11. CAPITAL 50A DP SWITCHES R3.05 Max panel thickness 1.5mm countersunk screws. Max panel thickness 2.7 10.1 30.6mm. A B C D = = = = B 15.4 30.6 * Fixing holes drill to accept 4mm countersunk screws.1 30.5mm countersunk screws. single screw fixing to grid.1 Max panel thickness 1.6mm.3 17.5mm countersunk screws.3 7.65 60.3 l 40mm 18mm 35mm 3mm These dimensions are a guideline only.3 17.5 D 4512/1 & 4512/13 C 4512/13 52 31 61.5 2 holes 3.00 Dia Hole Detail B B l For Rockergrid switches and accessories. Max panel thickness 1.5mm countersunk screws. 25.0 4011/13 & 4012/13 60.4 Dia CAPITAL 5A ROUND PIN SOCKET OUTLETS l DIMENSIONS WIRING ACCESSORIES List No 2240/1 * Fixing holes drill to accept 3.6 6173/1 60.15 15.5mm.3 Dia 0.5mm.6 60.7 2 holes 12.0 B l List No *A* B C D 4512/1 52 31 61.8 25. Extra screws to order.7 D C C – – – R1.3 33.3 17.0 60.8 19 29. 2 holes 10. 8 30.0 55.0 J H G AB C D PLATINUM 10AX / 6A TP ISOLATOR SWITCH E F l List No A* B C D 1170/1 50.0 50.50 17.PANEL CUT-OUT DETAILS l PLATINUM 13A SINGLE SOCKET OUTLET l List No A* B C D E F G H I J K 1314/1 38.0 1096/1 50.8 24.4 13.5 1.5 1. more detailed drawings are available upon request.75 6.5 30.0 28.0 29.8 24.4 13.5 20.20 14.8 24.5 38.5 30.3 K F G J R1.65 10.0 L M N P - - - - P N 1314/13 38.8 B A B C D DIMENSIONS WIRING ACCESSORIES PLATINUM 13A FUSED CONNECTION UNIT These dimensions are a guideline only.7 14.50 E D C A B List No A* B C D E F 1832/1 27.50 17.5 30.7 14.0 13.15 10.5 38.8 24.0 12.5 30.8 18.3 16.0 28.5 20.0 19. 125 .75 6.0 28.4 50.5 20.8 18.4 13.60 l G H I J K - - - - 50.0 32.0 16.60 24.8 l J K L - - - M M H L 1316/13 110 38.0 13.3 127.4 50.0 13.7 30.0 K 1832/13 27.0 - 1173/1 - 49.8 10.0 12.0 13.2 25.8 20.0 55.15 D C B F E M J K L R1.30 16.30 33.4 13.0 16.5 20.50 H G A PLATINUM 13A TWIN SOCKET OUTLET List No A* B C D E F G H I 1316/1 110 38.20 14.0 28.8 1017/1 - 49.7 30.0 - 1172/1 50.5 38.0 29.2 16.5 38. Light fittings can be conveniently un-plugged and re-connected into another LDB at a different point of the lighting circuit to provide optimum light and maximum flexibility. This can also be acheived with the 5 and 7 pin interiors as the 3 pin LSC plug fits all interiors. Commercial and office layouts may require frequent modification to the lighting requirements and the LDB can provide a cost effective solution when a number of units are connected through a lighting system. Height A Width B Depth C 5020/3 5020/4 5020/5 5020/7 180 180 180 180 245 300 366 445 70 70 70 70 8 way 5021/3 5021/4 5021/5 5021/7 180 180 180 180 245 300 366 445 70 70 70 70 10 way 5022/3 5022/4 5022/5 5022/7 180 180 180 180 245 300 366 445 70 70 70 70 6 way C B All dimensions are approximate and in mm.Technical Data D I M E N S I O N S L U M I N A I R E D I S T R I B U T I O N B O X E S & PAT C H PA N E L S LDB DIMENSION DETAILS 126 A List No. Other configurations of LDB are available on request. PATCH PANELS 465 32 18 way 24 way 76 48 way . A lighting system utilising LDBs with 4 pin interiors offers an emergency light circuit at every point but allows a 3 pin LSC plug to connect to offer standard lighting. Please allow for clearance of approximately 8mm for interior 21mm for the LSC plug when inserted. WARWICK 2 l 50 mm 42 mm 42 mm 85 mm 85 mm Profile assembly includes: • Base Unit • 1 x Base Extension • 1 x Main Cover 170 mm EXTERNAL DIMENSIONS. WARWICK 3 l • 1 x Square Cover • 2 x Main Covers Overall Size: • 212mm x 50mm D I M E N S I O N S WA R W I C K M O D U L A R P V C 50 mm Overall Size: • 170mm x 50mm Profile assembly includes: • Base Unit • 1 x Base Extension • 1 x Main Cover • 1 x Square Cover EXTERNAL DIMENSIONS. WARWICK 1 l Profile assembly includes: • Base Unit • 2 x Angled Covers 85 mm 212 mm • 1 x Angled Cover • 2 x Main Covers 42 mm 50 mm Overall Size: • 212mm x 50mm Overall Size: • 170mm x 50mm EXTERNAL DIMENSIONS. WARWICK 5 l 127 .50 mm 50 mm 42 mm 42 mm EXTERNAL DIMENSIONS. WARWICK 4 l Profile assembly includes: • Base Unit • 1 x Angled Cover Profile assembly includes: • Base Unit • 2 x Square Covers 85 mm 42 mm 170 mm • 1 x Main Cover Overall Size: • 170mm x 50mm 212 mm 85 mm 85 mm 42 mm 85 mm 170 mm 42 mm EXTERNAL DIMENSIONS. APPROXIMATE DIMENSIONS (mm) l SURFACE ALL-INSULATED ENCLOSURES List No A B C 404/0A 160 117 102 406/0A 230 190 120 409/0A 230 243 120 412/0A 230 294 120 415/0A 230 344 120 420/0A 230 439 120 l A B C SURFACE METAL-CASED ENCLOSURES List No A B C 804/0A 210 117 121 806/0A 210 188 121 809/0A 210 241 121 812/0A 210 292 121 815/0A 210 353 121 820/0A 210 438 121 l A T E C H N I C A L D ATA S TA R B R E A K E R C 128 FLUSH METAL-CASED ENCLOSURES List No A B C 809/0AF 250 281 121 812/0AF 250 332 121 815/0AF 250 393 121 820/0AF 250 478 121 B l A C B . 5 335 100 85 319 * Allow 4mm for dolly clearance. C B D E B SPINE BACKPLATE ASSEMBLIES (WHITE PVC COVER) l List No 915/0W A B C D E 220. C A D T E C H N I C A L D ATA S TA R B R E A K E R SPINE BACKPLATE ASSEMBLIES (METAL COVER) l B E 129 .APPROXIMATE DIMENSIONS (mm) l 2 BANK SURFACE METAL CASED ENCLOSURES List No A B C 824/2A 450 292 121 830/2A 450 353 121 840/2A 450 438 121 l A C CUSTOM BUILT CONSUMER UNITS List No A B C D E F 814/13 230 505 115 175 450 25 829/2463 480 505 115 410 450 25 832/24 480 505 115 410 450 25 B l F D A The above are Starbreaker interiors mounted in a Crabtree Polestar style enclosure – available to order. E C List No 915/0M A B C D E 152 335 100 85 319 A * Allow 4mm for dolly clearance. 5 31.- 90 35 75 L l A C T E C H N I C A L D ATA L I F E S TA R 4 MODULE RESIDUAL CURRENT CIRCUIT BREAKERS List No A B C 244/ . G B H C 2 MODULE RCBOs (MCB/RCDs) List No A B *C* D E 6132/0 .35 K P R1.5 M R 14.-.5 4414/A10 - O S 14.00 CL G F C R1.8 27..241/A .35 J G – N R1.9 32. C These dimensions are a guideline only..60 D M C E R0.2 38.4 S H – R1..6 79.8 7..- 90 70 75 244/A .4 72. 246/ .4 63.9 32. 226/A .- 198 98 99 104 – 116 88 50 l F D A * Allow 4mm for dolly clearance..7 O P 31. 226/ ..85 56.85 113.9 12.15 7.-.60 L N D J B A R1.6 39.-.-.45 14.. 228/ ..48 43.8 38.. 228/A .- 198 98 99 104 – 116 88 50 641/A .60 R0.75 28.6 20.3 20...00 P L CL F K O Q H R1.2 38. 130 B B .6 4416/A10 - 120.9 M N 13.-..7 13.241/ .60 D 4416/A10 - CL E B D A 2 MODULE RESIDUAL CURRENT CIRCUIT BREAKERS List No A B C 223/A010 90 35 75 224/ . more detailed drawings are available upon request.5 28.- 90 70 75 B l A C 5 MODULE RESIDUAL CURRENT CIRCUIT BREAKERS List No A B *C* D E F G H 641/ .1 Q R L 18.- 90 35 75 224/A ..8 38.0 87 36 75 45 50 l A D E * Allow 4mm for dolly clearance.-..-.4 51.APPROXIMATE DIMENSIONS (mm) l 13A 1 & 2 GANG SRCD (SAFETY SOCKET) List No A B C D E F G H l Q J K 4414/A10 - 120.-. 246/A .8 56.45 14. B C List No CBE4 A B C D E F G 160 110 114 140 90 69 96 l E F DA C 4 & 5 MODULE FABRICATED STEEL ENCLOSURE P20 List No A B C D E 844/4 223 112 66 184 73 EN100 412 340 115 305 229 B G l D A C E B T E C H N I C A L D ATA L I F E S TA R 4 MODULE ALL-PURPOSE ENCLOSURE P65 131 .APPROXIMATE DIMENSIONS (mm) l 3 MODULE GENERAL PURPOSE ENCLOSURE P20 List No A B *C* D E 744/3 150 60 89 68 38 l E D * Allow 4mm for dolly clearance. A B C 3 MODULE ALL-PURPOSE ENCLOSURE P65 List No CBE3 A B C D E F G 160 85 114 140 65 69 96 l E F DA C 4 MODULE GENERAL PURPOSE ENCLOSURES P20 List No A B *C* D E 744/4 150 77 105 68 56 744/41 210 77 105 68 56 l B G D E A * Allow 4mm for dolly clearance. 5 CIK24-40 84 35 65.5 45 60 48.5 45 60 48.5 CIK40-31 84 53.5 45 60 48.5 65.5 45 60 48.5 CIK63-40 84 53.5 45 60 48.5 65.5 45 60 48.5 65.5 CIK63-31 84 53.5 CIK40-22 84 53.5 45 60 48.5 CIK24-31 84 35 65.5 301/161 84 18 59 45 53 44 301/162 84 18 59 45 53 44 301/16CO 84 18 59 45 53 44 TWILIGHT SWITCH E A D F B C l LIST No A B C D E F G H J K L 303/P2 86 54 66 45 60 46 116 61 27 25 – C B E J D G F K H A .5 65.5 65.APPROXIMATE DIMENSIONS (mm) TIME SWITCHES LIST No l l A B C D E F G H J K L 303/TS24 90 54 66 45 60 46 – – – – – 303/TQ24 90 54 66 45 60 46 – – – – – 303/TQ7 90 54 66 45 60 46 – – – – – 302/TD1 86 36 66 45 60 40 – – – – – 302/TD2 86 36 66 45 60 40 – – – – – E Analogue A D Digital G B F Staircase 301/S7 84 18 70 BELL TRANSFORMER 45 60 43 25 – – – – C l LIST No A B C D E F G H J K L 303/B12 90 36 59 45 53 44 45 78 – – – E D H A F G B T E C H N I C A L D ATA C O N T R O L M O D U L E S C 132 CONTACTORS & IMPULSE RELAYS l LIST No A B C D E F CIK22-20 84 17. NUMERICAL INDEX WIRING ACCESSORIES INSTALLATION BOXES & SERVICE ITEMS CIRCUIT PROTECTION PVC TRUNKING 133 . 40 4307 & 4307/3 4 4520/1 & 4520/31 8 5010/2 – 5010/4 77 63 4521/1 & 4521/31 8 5011 – 5013 75 64 4522/1 & 4522/13 64 5014 4522/3_ _ 37 5015 75 8 5016 75. 24 4013/3 1314/1_ _ 22. 40 32 32. 48 1240/1_ _ 22. 24 4096/B & 4096/P 22. 25 1901 – 1904 47. 40 32 32. 48. 49 1011/13_ _ 23. 41 4436 47. 25 3443 18 4416/A01 & 4416/A03 34 4550/9_ _ 49 1017/1_ _ 22. 49 4841/_ _ 33 4097/B & 4097/P 15 4490 47. 25. 42 4314/3_ _/9 & 4314/_ _/9 2402 11. 24 4096/2WB 1837/13_ _ 22. 48 4842/BG 53 1908 26. 25. 24 4012/3_ _ 35. 48 4837/_ _/9 32 47. 48 5017 & 5017/_ 75 2411/_ _ 37. 40 32 4836/1 63 27 4836/_ _ 32 4460/7_ _ 26 4837/1 & 4837/13 63 4460/9_ _ 47. 41 2272/BG 54 4250W/_ _ 5006 75 75. 24 4014/3_ _ 5 4430/6_ _ 4009 14 4430/7_ _ 26 4827 & 4827/3 4011/1 & 4011/13 65 4430/9_ _ 47. 48 4581/BG .4176 14 4491 47. 28 47 47. 72 3463/BK & 3463/WH 18 4426/A01 & 4426/A03 33 4553 54 4553/9_ _ 7577/_ _ 23 3809BG 55 4426/A01BG & 4426/A03BG 8577/_ _ 25 3899BG 55 4430 47. 27 4170 . 48 47 54 4587/BG 55 4001 – 4004 1170/1_ _ 25. 48 4015/31 7 4460 47. 77 2400 11. 49 4828 & 4828/3 1316/13_ _ 22. 77 4513/BG & 4514/BG 55 5 4304 & 4304/_ _ 4 4513/WH – 4515/WH 9 2340/_ _ 34 4306 & 4306/_ _ 4 4515/_ _ 2372/_ _ 34. 41 5002 & 5002/_ 75 4216/BG 53 4512/BG 54 2272/1 64 4216/_ _ & 4216/_ _/9 33 4512/_ _ 34. 24 3450/9 17 4416/A101 & 4416/A103 63 4551 1091/1 7575/_ _ 8585/_ _ 1092/1 23. 48. 48. 49 4015/3 7 4451 47. 60 4841/BG 53 14 4489/9_ _ 47. 48 27 23. 42 4012/1 & 4012/13 65 4440 49 1272/1_ _ 22. 25 3432 17 4414/A01 & 4414/A03 34 4550 1011/1_ _ 23. 48 4847/3BG 53 2163 11 4214/3_ _ & 4214/3_ _/9 33 4500 & 4500/_ _ 9 4847/3_ _ 33 2167 11 4214/BG 53 4506 & 4507 2190 14 4214/_ _ & 4214/_ _/9 33 4512/1 & 4512/13 2240/1 64 4216/3BG 53 2240/BG 54 4216/3_ _ & 4216/3_ _/9 33 2250W/_ _ 35. 42 4316/1 & 4316/13 63 4530/6_ _ 27 5018 & 5018/_ 75 3250W/_ _ 35. 24 4017 7 1512/13_ _ 23. 48. 49 3401 & 3402 18 4316/3_ _ 3410 17 4316/3_ _/9 & 4316/_ _/9 3412 17 4316/_ _ 32. 48. 48. 60 4837/3_ _ 32. 25 1172/1_ _ 23. 41 4435 47. 60 27 75. 77 2330 2382 5 4314/1 & 4314/13 35. 24 4015 1316/1_ _ 22. 60 4846/_ _ 33 2161 11 4214/3BG 53 4499 47. 40 32 32. 48. 42 4316/139/_ _ & 4316/19/_ _ 64 4530/7_ _ 26 5019 & 5019/_ 75 32. 48 4842/3BG 53 4130 & 4132 14 4490/9_ _ 47. 40 4530/9_ _ 47.4180 15 4492 47. 24 26. 48 47 47. 24 1400LV/_ _ 4 4 4831/1 63 4831/_ _ & 4831/3_ _ 32 4832/1 & 4832/13 63 4832/19/_ _ & 4832/139/_ _ 64 7 4450/6_ _ 27 4832/3_ _ 35 4450/7_ _ 26 4832/3_ _/9 7 4450/9_ _ 47. 60 1314/13_ _ 22. 25 4020/3BG & 4021/3BG 54 4461/ELT 1522/1_ _ 23. 25 4018 7 4461 1522/13_ _ 23. 60 1250W/_ _ 35. 41 4450 47. 60 35. 42 5003 – 5005 36 5006/2 – 5006/4 77 5007 – 5009 75 5010 75. 60 48 47. 15 4314/139/_ _ & 4314/19/_ _ 2400/E 11. 48. 42 4016/3 7 1410/1* 22. 49 4841/3BG 53 4480 48 4841/3_ _ 33 14 4489 47. 48 4846/BG 53 2147 15 4211/BLANK 8 4494 47. 40 4523 & 4523/3 4530 4535 4535/6_ _ 47. 27 4177 . 25 1173/1_ _ 23. 24 4011/_ _ 35. 25 4011/3_ _ 35. 15 4314/3_ _ 2400W/_ _ 35. 48. 24 3450 17 4416/A01BG & 4416/A03BG 54 4550/9_ _ 1075/1_ _ 22. 25 4017/1 7 4460/_ _ 1512/1_ _ 23. 49 4842/3_ _ 33 48 1906 26. 15 4314/_ _ 47. 25 3442/CFL 17 4414/A101 & 4414/A103 63 4550/7_ _ 26 1012/1_ _ 23. 48.4583/BG 1096/1_ _ 1837/1_ _ NUMERICAL INDEX List No 6 224/030 134 Page No 4832/_ _ 4832/_ _/9 32. 49 4837/19/_ _ & 4837/139/_ _ 64 48 47. 77 5020/3 – 5020/5 77 5020/7 77 5021/3 – 5021/5 77 . 25 3442 17 4414/A01BG & 4414/A03BG 54 4550/6_ _ 27 1012/13_ _ 23. 25 4070 14 4469 1630W/_ _ 42 4075 9 4469/9_ _ 1832/13_ _ 22. 24 1340/1_ _ 22. 27. 48. 48. 72 3450/9CFL 17 4424/A01 & 4424/A03 33 4551/ELT 23 3450/CFL 17 4424/A01BG & 4424/A03BG 54 4552 25 3462/BK & 3462/WH 18 4425 49 4552/9_ _ 23. 42 8 4847/BG 53 65 4847/_ _ 33 4512/3BG 54 5001 & 5001/CVR 75 4512/3_ _ 34. 40 4837/3_ _/9 32 4837/_ _ 32 47. 48 4842/_ _ 33 2141 15 4190 & 4192 14 4493 47. 24 4077 15 1832/1_ _ 22.WIRING ACCESSORIES List No 13NP & 13NPRD Page No List No Page No List No Page No 3420 17 4404/A01 & 4404/A03 4 4535/7_ _ 26 59 3422 17 4406/A01 & 4406/A03 4 4535/9_ _ 47. 42 4016 7 4460/6_ _ 1400W/_ _ 35. 50 7111 6 6562/_ _ 46. 50 7091 72 8094/1 6561/_ _ 46. 50 6570/24_ _ 47. 51 5 7711/_ _ – 7714/_ _ 26 9342/GV 47. 43 7305 73 8507/_ _ 25. 51 7501 – 7503 73 8518/_ _ 27 NUMERICAL INDEX 7080/LH 47. 49 7515/_ _ 22 9203/BG 5855 & 5855/_ _ _ 16 6915 71. 46. 50 34. 51 46 47. 42 7011/_ _ _ 29 6141/_ _ 35. 51 7501/_ _ 23 8532/_ _ & 8532/3_ _ 25 5022/7 77 6589/BG 46. 49 6880 19 7507/_ _ 23. 50 7086 71 8092/1 6560/_ _ 46. 51 7324 73 8510/_ _ 24 TNS/1/BK – TNS/3/BK 18 6580/BG 46. 41 7067 71 7915 71 9561/DL 59. 72 List No 8832/_ _ & 8832/3_ _ 29 8T01/_ _ – 8T04/_ _ 28 65 6999 19 7533/_ _ & 7533/3_ _ 22 9209/18PBG 6096/_ _ 35. 41 7071 71 8011/_ _ & 8011/3_ _ 29 9561/ES 65 7074 71 8075/1 64 9561/L 61 35. 48 7532/_ _ & 7532/3_ _ 23 9209/18BG 6096/1 List No 43. 60. 50 7172/_ _ & 7173_ _ 29 6568/_ _ 46. 42 7046 – 7048 6151/_ _ 35. 51 7400/D1_ _ & 7400/D2_ _ 23 8515/_ _ 24 6583/BG 46. 43 9573/L & 9573/RL 9579 59 59 59. 72 9563/L 61 8170/_ _ 29 9564/E 59. 60 60 58. 50 7288 73 8506/_ _ & 8506/3_ _ 24 9685/BG 53 6577/_ _ 36. 50 7087 71 8092/_ _ 6561/1_ _ 46. 46. 46. 59 4 8314/_ _ 29 9581/RG & 9582/RG 7259 63 8316/_ _ 29 9591/L – 9593/L 60 60 6572/_ _ 43. 50 7170/_ _ 29 6564/_ _ 46. 50 7504/_ _ & 7504/3_ _ 22 8546/_ _ & 8546/3_ _ 25 5175 15 6758/WH 46 7505 73 8560/_ _ 24 5177 15 6852 19 7505/_ _ 22 8578/_ _ & 8579/_ _ 24 5430/_ _ 28. 50 7161/_ _ & 7162/_ _ 34 6563/_ _ 46. 50 6570/18_ _ 47. 50 6572/1_ _ 46. 61 8172/_ _ & 8173/_ _ 29 9565 8250/D1_ _ & 8250/D2_ _ 25 9565/L 59. 50 7222/BK & 7222/WH 6570/_ _ 46. 49 22 23. 50 7318 73 8509/_ _ 25. 50 7284 73 8504/_ _ & 8504/3_ _ 24 9664 58 6575/_ _ 36. 50 7094 72 6562/1_ _ 46. 51 46 59 59. 42 7060 6152/_ _ 35. 50 7283 73 8501/_ _ – 8503/_ _ 25 9660 & 9660/_ 58 6574/_ _ 43. 50 7314/_ _ & 7316/_ _ 29 8508/_ _ & 8508/3_ _ 24 9687/BG 53 6579/_ _ 46. 50 7503/_ _ 23 8545/_ _ & 8545/3_ _ 25 5172 & 5713 15 6592/_ _ 47. 50 6900/1 & 6900/1RD 18 7509/_ _ 5801 16 6900/2 & 6900/2RD 18 7510/_ _ 22 9201/BG 5850 16 6901 – 6904 7511/_ _ – 7514/_ _ 27 9201/PBG 5851 16 6906 47. 40 72 61 59. 51 46 46. 61 9562/E 61 36. 49 6878 19 7506/_ _ & 7506/3_ _ 22 8711/_ _ – 8714/_ _ 26 5550/_ _ 28. 72 9685/_ _ 33 6578/_ _ 46. 41 7063 71 7718/_ _ 26 9561/1L 47 46. 73 7516/_ _ 27 9203/PBG 5856 16 6920/_ _ 6 7518/_ _ 27 9206/BG 5860 & 5861 16 6925 6 7520/_ _ _ 23 9206/PBG 6017/_ _ 36 6940 47. 49 6900 18 7508/_ _ & 7508/3_ _ 5571 –5574 46. 60 65 7065 71 7832/_ _ & 7832/3_ _ 29 9561/2L 60 35. 42 65 36. 72 8716/_ _ & 8718/_ _ 26 5552/_ _ 28. 42 7044 6142/_ _ 35. 51 5 7716/_ _ 26 9561 71 35. 51 7546/_ _ & 7546/3_ _ 23 9209/24PBG 7560/_ _ 22 9209/BG 5 7578/_ _ & 7579/_ _ 22 9209/PBG 7697 18 9341/GV 47. 60 7221 & 7221/3 6 8265/1 – 8268/1 65 9570/2 59. 51 7501/2 73 8520/_ _ & 8520/3_ _ 25 5022/3 – 5022/5 77 6588/BG 46.WIRING ACCESSORIES List No Page No Page No List No Page No 5021/7 77 6586/BG 46. 59 23 8283/1 & 8284/1 4 8283/_ _ & 8284/_ _ 36. 50 7176 6569/_ _ 46. 72 9562/L 61 72 9563/E 59. 51 47 47. 46. 50 7265 – 7271 73 8400/D1_ _ & 8400/D2_ _ 25 9599 59 6573/_ _ 43. 43 7286 73 8505/_ _ 24 9668 58 6576/_ _ 46. 51 7348 73 8511/_ _ – 8514/_ _ 27 6581/_ _ _ & 6582/_ _ _ 46. 60 65 7069 71 7T01/_ _ – 7T04/_ _ 28 9561/E 35. 41 7011 6 7545/_ _ & 7545/3_ _ 23 9209/24BG 6125/_ _ 35. 50 7172 – 7174 71 6566/_ _ 46. 72 9687/_ _ 33 6580/18BG & 6580/24BG 47. 50 7255 & 7255/TE 43. 60 8255/1 63 9566/E 61 8255/_ _ 32 9567 71 8257/1 63 9567/L 7211 6 8257/_ _ 32 9569/L 59. 41 7080 71 8075/_ _ 9562 59 51 71 8091/1 7081 & 7081/2 71 8091/_ _ 6560/24_ _ 47. 61 8094/_ _ 36. 72 9562/ES 59 72 9562/ES 61 36. 42 7061 7062 & 7062/E 6170/1 6170/_ _ 6172/1 6172/_ _ 6173/1 6173/_ _ 6175/1 6175/_ _ 6551/_ _ – 6554/_ _ 65 46 46. 50 7257 & 7257/TE 46. 61 6 8265/_ _ – 8268/_ _ 9571 & 9572 58. 46. 51 7410RD & 7410WH 18 8516/_ _ 27 6584/BG 46. 51 7502/_ _ 23 8533/_ _ & 8533/3_ _ 24 5170 15 6591/_ _ 47. 51 5 6560/18_ _ 6571/_ _ Page No 135 . 50 7250 /D1_ _ /D2_ _ 6571/1_ _ 46. 84 BCL4/SER 80. 87 BCL/BB3 86. 84 BCL4/CP 80. 82 BCL2/SEL 80. 82. 83 BCL3/EB 80. 81 BCL1/FAD 80. 85 BCL5/IB 80. 83. 85 BCLBBTB 87 100/_ _ _ 216/A010 221/_ _ _ _ 223/_ _ _ _ 224/_ _ _ _ 226/_ _ _ _ 228/_ _ _ _ 241/_ _ _ _ _ 243/030 244/_ _ _ _ 246/_ _ _ _ 301/_ _ 302/_ _ _ 303/_ _ _ _ 310/_ _ _ _ _ 325/_ _ _ _ 340/_ _ _ _ 363/_ _ _ _ _ 380/_ _ _ _ _ 40/MI2 402/_ _ _ 404/0A 404/_ _ _ _ 405/232 406/OA 407/_ _ _ _ 408/_ _ _ _ _ _ 409/242124 409/OA 410/_ _ _ _ 410/_ _ _ _B 411/_ _ _ 412/OA 413/2 413/23624 413/25626 413/26786 413/2B 413/313 413/383 414/_ _ _ _ _ _ 415/_ _ _ _ 415/_ _ _ _B 415/OA 416/_ _ _ _ 418/_ _ _ 420/OA 4404/_ _ _ 4406/_ _ _ 4414/_ _ _ _ 4416/_ _ _ _ 4424/_ _ _ _ _ 4426/_ _ _ _ _ 443 61/_ _ _ _ _ _ 6106/_ _ _ 6110/_ _ _ 6116/_ _ _ 6120/_ _ _ 6132/_ _ _ 6140/_ _ _ 63/MI2 741 744/_ _ 748 799 802/_ _ _ 804/0A 804/_ _ _ _ 805/232 806/OA 807/_ _ _ _ 807/_ _ _ _F 808/_ _ _ _ _ 809/242124 809/O_ _ 810/_ _ _ _ 810/_ _ _ _B 91 103 103 103 103 103 103 103 103 103 103 100 100 100 91 91 91 91 91 91 94 90 94 95 90 94 95 95 90 94 99 95 90 94 95 95 95 99 94 94 95 94 99 90 95 94 90 102 102 102 102 102 102 100 91 103 103 103 103 103 103 91 100 104 100 100 96 90 96 97 90 96 99 97 97 90 96 99 811/_ _ _ 812/OA 812/OAF 813/2 813/23624 813/23824 813/25626 813/25826 813/26786 813/28786 813/2B 813/2F 813/313 813/383 813/383F 814/272126 814/282125 815/_ _ _ _ 815/O_ _ 816/_ _ _ _ 817/_ _ _ _ _ 818/_ _ _ 820/283 820/O_ _ 823/_ _ _ _ _ 824/2A 826/283 830/2A 833/_ _ _ _ _ 836/283 840/2A 844/4 910/_ _ _ _ 913/_ _ _ 915/_ _ 920/OW/435 943W CBE/_ _ CBE3/_ _ CBE4/_ _ CHHSLA11 CHHSLA20 CIK22-_ _ CIK24-_ _ CIK40-_ _ CIK63-_ _ EN100 MCBLD ME/FB 97 90 90 96 97 97 97 97 97 97 99 99 96 96 99 97 97 96 90 97 98 96 98 90 98 90 98 90 98 98 90 104 98 98 90 90 100 104 104 104 100 100 100 100 100 100 104 100 104 . 81 BCL1/FTD 80. 82 BCL2/SER 80. 83 BCL4 80. 84 BCL/ACS 80 BCL/ADPL 80 BCL/ASS 80 BCL/BB05 87 BCL/BB1 86. 87 BCL/BBCA 87 BCL/BBCB 87 BCL/BBMC 87 BCL/BBO5 86 BCL/BBSB 87 BCL/BBSL 87 BCL/BBSR 87 BCL/BE 80 BCL/MC 80 BCL/RCD 80 BCL/SCR 80 BCL/SCS 80 BCL/SGB 80. 85 BCL5/EB 80. 82. 85 BCL/SSS 80 BCL/TGB 80. 83. 85 BCL5/CP 80. 82. 84 BCL4/FAD 80. 84 BCL4/FAU 80. 81. 84 BCL4/SEL 80.INSTALLATION BOXES PVC TRUNKING List No List No 4005 4006 9040 – 9044 9047 – 9050 9052 – 9054 9211/_ _ _ 9214/_ _ _ 9215/BG 9221/_ _ _ 9223/_ _ _ 9224/BG 9406 LPU1 LPU2 LPU2TA LPUD1 LPUD2 LPUD2TA Page No 67 67 67 67 67 68 68 68 68 68 68 67 68 68 68 68 68 68 NUMERICAL INDEX SERVICE ITEMS 136 List No 1250 3467 3711 3713 3767 4674 6509 6900 6900/1RD 6900/1WH 6900/2 6900/2RD 6913 6988 6989 7410/RD 7410/WH 7695 7697 15244 15485-2/L/4 100215 705094/* 705094/*/VR 706097 735006/ZP 735007/ZP 735008/* 735009/*/VR 735010* 735010/*/VR 735011* 735011/*/VR 735012* 735013* 735023 735032 735033 735038 Page No 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 CIRCUIT PROTECTION Page No BCL/ACR 80. 85. 84. 84 BCL4/FTD 80. 85. 83 BCL3/FTD 80. 85 BCL5/FAD 80. 84 BCL5 80. 81 BCL1/CP 80. 81 BCL1/IB 80. 84 BCL4/IB 80. 83 BCL3/IB 80. 84 BCL4/EB 80. 83 BCL3/SEL 80. 87 BCL/SQCR 80. 81 BCL2 80. 84 BCL4/FTU 80. 85 BCL5/FAU 80. 82 BCL2/IB 80. 85 BCL5/SEL 80. 85 BCL5/FTU 80. 82 BCL2/FAD 80 BCL2/FAU 80. 84. 81. 83 BCL3/CP 80. 81 BCL2 /CP 82 BCL2 /FAD 82 BCL2 /FTD 82 BCL2/CP 80 BCL2/EB 80. 81 BCL1/EB 80. 81. 85 BCL5/SER 80. 87 BCL1 80. 82. 82 BCL3 80. 85 BCL5/FTD 80. 81 BCL1/SEL 80. 83. 83 BCL3/FAD 80. 82 BCL2/FTD 80 BCL2/FTU 80. 15. drawings. restriction or condition and without any deduction or withholding for or on account of any counterclaim or any present or future taxes. 10.3 apply to overseas transactions in place of the provisions of clause 4. 11 INTELLECTUAL PROPERTY 11.3 any maintenance requirements relating to the Goods have not been complied with. container depot or at any other inland destination or provides his own transportation or where packing of a lesser standard is required. as far as is possible. Brownhills.5. however caused.5%. registered designs.2 any such sale will be a sale of Electrium’s property on the Customer’s own behalf and the Customer will deal as principal when making such a sale.2 above.9 The Buyer acknowledges that the above provisions of this Condition 10 are reasonable and reflected in the price which would be higher without those provisions. or refinished or dismantled. lockouts or other industrial disputes (whether involving the work force of Electrium or otherwise).2. until either the breach is remedied or the Contract terminates. 14. both before and after any judgment. The provisions of this clause 16.2. insolvent.2 Time for performance of all obligations of Electrium under the Contract is not of the essence. and in any event no later than 12 months from the date of delivery. all sums payable to Electrium under the Contract will become due immediately upon termination of the Contract.6 Electrium will be entitled to increase the price of the Goods following any changes in the specification made both at the request of the Customer and agreed by Electrium or to cover any extra expense as a result of the Customer’s instructions or lack of instructions. construction. depletion of goodwill and like loss). 16. 10.1. design. and will whenever requested by Electrium produce a copy of the policy of insurance. CONDITIONS OF USE All products supplied by Electrium should be installed by suitably qualified personnel in accordance with the requirements of relevant legislation.1.7 Electrium may assign. Any quotation is valid for a period of 30 days only from its date. 12. all conditions.1 Electrium will be deemed not to be in breach of the Contract or otherwise liable to the Customer in any manner whatsoever for any failure or delay in performing its obligations under the Contract due to Force Majeure. 10. Electrium hereby excludes to the fullest extent permissible in law. The headings in these Terms and Conditions are for convenience only and shall not affect their construction or interpretation. 3. 13.6.4 to 10. EXCLUSION OF LIABILITY AND INDEMNITY Warranty 10.1 for the unexpired portion of the 12 month period from the original date of delivery of the replaced Goods. commissioned and maintained in accordance with good engineering practice and under the supervision of suitably qualified personnel. provided that it has and continues to comply with its obligations set out in clause 14. 13. the amount of such increase or reduction shall be added to or deducted from the Contract price as the case may be. 7 DELIVERY 7. If.8. This obligation will not apply where: 10. customary or otherwise which. Any repaired or replacement Goods will be liable to repair or replacement under the terms specified in clause 9.3 and 10.4 any statement made or not made.4. 4.7 If any sum payable under the Contract is not paid when due then. 8.1 The price for the Goods is exclusive of VAT or any successor tax thereto unless otherwise agreed in writing. 9 THE GOODS 9. without prejudice to Electrium’s other rights under the Contract.2 The price of Goods includes the cost of packing for shipment FOB (Incoterms 2000) to a British port or FCA (Incoterms 2000) to a British airport except that orders having a net value of £500 and below shall be subject to an additional charge to cover packing and carriage. makes any composition with his creditors. the Customer will be deemed to have sold all goods of the kind sold by Electrium to the Customer in the order in which they were invoiced to the Customer. tort (including negligence). 4. 8. unless the Customer is required by law to make any such deduction or withholding. 10.1 hold the Goods on a fiduciary basis as Electrium’s bailee . or within 14 days of the same coming to the knowledge of the Customer where the defect is not one which should be apparent on reasonable inspection. 15.5. deface or obscure any identifying mark or packing on or relating to the Goods.3 Electrium reserves the right to alter the method of packing without reference to the Customer. 15. 10. or the manufacture or sale or supply.5. workmanship or design (other than a design made. specifications and advertising issued by Electrium (or the manufacturer of the Goods) and any descriptions or illustrations contained in Electrium’s (or the manufacturer’s) catalogues or brochures are issued or published for the sole purpose of giving an approximate idea of the Goods represented by or described in them. 13. 15.3.5 the Customer has failed to notify Electrium of any defect or suspected within 14 days of delivery where the defect should be apparent on reasonable inspection.3. 8.4 for any matter which it would be illegal for Electrium to exclude or to attempt to exclude its liability. payment is due on delivery.2 apply to overseas transactions in place of the corresponding provisions of clause 3.2 Time for payment will be of the essence. pro ceedings or legal costs (on a full indemnity basis) and judgments which Electrium incurs or suffers as a consequence of a direct or indirect breach or negligent performance or failure in performance by the Customer of the terms of the Contract. 5 PACKING MATERIALS 5. at cost and Electrium will. Each order or acceptance of a quotation for Goods will be deemed to be an offer by the Customer to purchase Goods upon these Terms and Conditions.3. an act of terrorism.3 Without prejudice to the above provisions. 7.8 Where Electrium is unable to determine whether any Goods are the goods in respect of which the Customer’s right to possession has terminated.3 and 10.3 The price for the Goods is inclusive of costs of carriage to the Customer’s premises in Great Britain and Northern Ireland except on individual orders having a net value calculated by reference to the Company’s most recent price list of less than £200 (excluding VAT) which shall be subject to an additional charge of not less than £15. 10. utility models. malicious damage. 5.2. 4 PAYMENT 4.1 is a material breach of the terms of the Contract which is not capable of remedy.6. 8. and 8.1 Packing cases and cartons will be provided free of charge by Electrium. as if the words “its employees. storm. 6 DAMAGE OR LOSS IN TRANSIT 6.2. such interest to accrue daily and be calculated on a daily basis. 4. or about conditions of use. loss of profits. restraints or delays affecting shipping or carriers “Goods” any goods which Electrium supplies to the Customer (including any of them or any part of them) under a Contract “Intellectual Property Rights” all intellectual and industrial property rights including patents. No contract will come into existence until a written acknowledgement of the order is issued by Electrium.4 Electrium will be entitled to suspend any deliveries otherwise due to occur following service of a notice specifying a breach under clause 13.1. express (other than those set out in the Contract) or implied. but for such exclusion. depletion of goodwill and like loss) howsoever caused arising out of or in connection with: 10. l l 10 WARRANTY. depletion of goodwill and like loss) howsoever caused (including as a result of negligence) by any delay or failure in delivery except as set out in this condition. has a receiver appointed under the Mental Health Act 1983 or dies.2 Where the Goods are accepted from the Electrium’s carriers they shall be deemed to have been checked by the Purchaser and accepted unless the delivery receipt is signed and endorsed ‘unexamined’ and the packing and its contents are retained for later inspection.4 The Goods will be sold free on board to a British port or airport and Electrium will be under no obligation to give the Customer notice as specified in Section 32(3) of the Sale of Goods Act 1979. loss of business. 7. warranties and stipulations. In pursuance of Electrium’s policy of continuing product improvement. Goods shall be deemed to have been delivered when the invoice has been presented in the United Kingdom accompanied by the appropriate documents of title. where the Customer’s right to possession has terminated. and 8. or failure or delay in supply of the Goods by Electrium or on the part of Electrium’s employees. without limitation. including any terms or conditions which the Customer purports to apply under any purchase order. keep indemnified and hold harmless Electrium from and against all costs (including the costs of enforcement). at the rate of 3% per annum over The Royal Bank of Scotland plc base rate from time to time. Any delay in delivery will not entitle the Customer to cancel the order unless such delay exceeds 90 days.2 the Customer will be under no liability to make any further payment under clause 4. rights to prevent passing off for unfair competition and copyright.2. 15. power or remedy will operate as a waiver of it nor will any partial exercise preclude any further exercise of the same. labour.6 Electrium may appropriate any payment made by the Customer to Electrium to such of the invoices for the Goods as Electrium thinks fit.1 All samples. the Customer must: 8. then the Customer will be liable (without prejudice to any other rights of Electrium to claim damages) to indemnify and keep indemnified Electrium against any resulting loss.3.3 and 10. or 10.3 under section 2(3) Consumer Protection Act 1987. demands. validity and all aspects whatsoever of the Contract or of any term of the Contract will be governed by English law. The Customer shall remain liable to pay for the Goods delivered prior to the date of such cancellation. loss of business. the parties to the Contract do not intend that any of its terms will be enforceable by virtue of the Contracts (Rights of Third Parties) Act 1999 by any person not a party to it. 13. or 9. 4. damage or expense incurred by Electrium in connection with the supply or non-supply of the Goods including the cost of any material. or 13.1.6 Electrium will be entitled to recover payment for the Goods notwithstanding that title in any of the Goods has not passed from Electrium. 8. tribunal. loss of profits. equipment described in this publication is subject to change without notification.3 any use made or resale by the Customer of any of the Goods.2 Electrium may make any changes to the specification. duties and currency exchange rates ruling at the date of the quotation.5 No failure or delay by Electrium to exercise any right. CIF (Incoterms 2000) or cost and freight arrangements can be made if requested by the Customer.2 for personal injury or death resulting from Electrium’s negligence. civil commotion. statutory.1.2 The price for the Goods shall be (unless otherwise agreed by Electrium in writing) the list price of Electrium current at the date of despatch and in the case of an order for delivery by instalments the price payable for each instalment shall be Electrium’s list price current at the date of despatch for each instalment. obscured or omitted nor add any additional marks or words. Electrium will be entitled to suspend deliveries of the Goods until the outstanding amount has been received by Electrium from the Customer.1 Electrium will not be liable in respect of any damage or discrepancy.6 Except as provided in clauses 7.2 any breach by Electrium of any of the express or implied terms of the Contract. accident. agents and sub-contractors may rely upon and enforce the exclusions and restrictions of liability in clauses 7. 9. Electrium’s (but not the Customer’s) rights contained in this clause 8 will remain in effect.1 All Contract Terms set out above apply to overseas transactions (i.1 The Customer warrants that any design or instruction issued or given by the Customer shall not be such as will cause Electrium to infringe any Intellectual Property Rights in the execution of the Customer’s order and the Customer agrees to indemnify and keep Electrium indemnified against all liability in the event that such warrant is found to be untrue. All prices are based on standard pack sizes and quantities and Electrium reserves the right to levy an additional charge if such packs must be broken up to fulfil an order. 3.5 The Customer shall be solely responsible for complying with all legislation and regulations governing the importation of the Goods into the country of destination including import and export licences and the payment of duties thereon including but not limited to customs duties and VAT.1 is in material breach of any of the terms of the Contract and. descriptive matter. these Terms and Conditions may only be varied or amended in writing and signed by a director of Electrium. compliance with any law or governmental order.1 are required to conform with any applicable safety or other statutory (or regulatory) requirements.2. restitution or otherwise) for any injury. by or on behalf of Electrium or otherwise under the Contract.4. indirect or consequential loss (all three of which terms include.1. 8. without limitation. 3.4. administrative body or authority of competent jurisdiction to be illegal.2 becomes bankrupt.1 in respect of that order (or part of the order) which has been cancelled. and the Customer will accept such risk and/or insure accordingly.1 Subject to any variation under clause 2. is available on request.2 the Goods have been improperly installed or connected. fees.3.2 Electrium will refund to the Customer the cost of carriage on the return of any such defective or damaged Goods.2 The Customer shall ensure that any kits supplied hereunder are so assembled as to ensure that the assembled product is safe and complies with the requirements of any applicable safety regulations.3.50 will be made. injuries.6 Save as set out in clause 10. or national emergency. 10. agents and subcontractors” followed the word Electrium wherever it appears in those clauses save each reference in clause 10. 10. or the Company reasonably anticipates that one of the above set of circumstances is about to occur. hold on trust or sub-contract all or any part of its rights or obligations under the Contract. 3. and 8. 10.e.4 any instructions as to storage of the Goods have not been complied with in all respects. The provisions of this clause 16. the Customer shall use the Goods accordingly and comply with the said conditions. The Contract is formed when the order is accepted by Electrium. replace such Goods. power or remedy. Exclusion of Liability 10.7 The Customer grants Electrium.10 The Customer agrees to indemnify. 16 EXPORT 16. taxes. 14 FORCE MAJEURE 14. installed. 11. performance.1 any of the Goods.4 If any condition or part of the Contract is found by any court. and 7. To be properly used the Goods shall be selected. 10.6. 16.3 The Customer shall not without Electrium’s prior consent allow any trade marks of Electrium or other words or marks applied to the Goods to be obliterated. 3 PRICE 3. or fails to take delivery of any Goods at the time agreed (if any) or if no time is agreed within a reasonable time. duties and liabilities of either the Customer or Electrium. invalid or unenforceable then that provision will. 6.1 Electrium will. or re-sell the Goods in the Customer’s ordinary course of business.1 If the Customer cancels.2 Electrium may by notice in writing served on the Customer terminate the Contract forthwith if the Customer: 13. transport. modifying any other provision or part of the Contract and this will not affect any other provisions of the Contract which will remain in full force and effect. loss of business. Electrium will be under no liability to the Customer whatsoever (whether in contract.1. the Contract will be upon these Terms and Conditions to the exclusion of all other terms and conditions and all previous oral or written representations. No allowance will be made in lieu of transportation if the Customer accepts delivery at the factory.5 The Customer’s right to possession of the Goods will terminate immediately if any of the circumstances set out in clause 13.3.2 No right or licence is granted to the Customer in respect of Electrium’s Intellectual Property Rights. regulation or bye-law having the force of law that shall affect the performance of Electrium’s contractual obligations. on receipt of the Customer’s indemnity. 4.3 Each right or remedy of Electrium under any Contract is without prejudice to any other right or remedy of Electrium under this or any other Contract. 10. Unless otherwise agreed in writing. riot. 8 RISK / OWNERSHIP 8. flood. or have been subject to misuse or unauthorised repair.1 the Goods.1 for breach of Electrium’s obligations arising under section 12 Sale of Goods Act 1979 or section 2 Sale and Supply of Goods and Services Act 1982.2. epidemic or default of suppliers or subcontractors. 2 FORMATION AND INCORPORATION 2. 10. 15. without limitation. except the right to use.3 The termination of the Contact howsoever arising is without prejudice to the rights. or advice given or not given.5. 8. extend or delay the Contract or part thereof. sub-contracts. liabilities (including any tax liability). Indemnity 10.1 The Customer shall ensure that any modifications whatsoever made to the Goods supplied hereunder comply with the requirements of any applicable safety regulations. despite any purported appropriation by the Customer.5 All payments to be made by the Customer under the Contract will be made in full without any set-off. war.5 for fraud. 11. and (c) within twenty-one days of receipt of the Electrium’s invoice in the event of non-delivery. regulations (including the IEE Wiring Regulations) and the accepted practice in the industry. duties.1 the Goods have been improperly altered in any way whatsoever.8 The formation.3 No payment will be deemed to have been received until Electrium has received cleared funds. claims. without limitation.2 all other sums which are or which become due to Electrium from the Customer on any account.1 Electrium will refund to the Customer any sums which the Customer has paid to Electrium in respect of that order (or part of the order) which has been cancelled. 10. The English Courts will have non-exclusive jurisdiction to settle any disputes which may arise out of or in connection with the Contract. regulation or direction. specifying the breach and requiring it to be remedied. discovery or process. Failure to pay any sums due in accordance with clause 3. payment is due in pounds sterling on the last day of the month following the month of dispatch of the Goods.2 store the Goods (at no cost to Electrium) separately from all other Goods of the Customer or any third party in such way that they remain readily identifiable as Electrium’s property. registered trade marks.1 Risk of damage to or loss of the Goods will pass to the Customer on delivery.1 any sale will be effected in the ordinary course of the Customer’s business at full market value and the Customer will account to Electrium accordingly.1 to 10. where Electrium provides the Customer with information about the use for which Goods are designed and have been tested and about any conditions to ensure that when put to that use they would be safe and without risk to health. applications for and rights to apply for any of the foregoing.1 occur.3.00 (excluding VAT) to cover carriage and packing. its agents and employees an irrevocable licence at any time to enter any premises where the Goods are or may be stored in order to inspect them or. 10.1. by way of a written acknowledgement of order.2 do not materially affect their quality or performance. 13. to recover them. charges. the Customer fails to remedy such breach within 14 days service of a written notice from Electrium. sales outside the United Kingdom) where appropriate and except as set out in this clause 16. 13.2.2. The Customer must ensure that the terms of its order and any applicable specification are complete and accurate.4 ceases to trade or appears in the reasonable opinion of the Company likely or is threatening to cease to trade within 4 weeks. whichever occurs first. within a period of 12 months from the date of delivery of the Goods which are proved to the reasonable satisfaction of Electrium to be damaged or defective due to defects in material. West Midlands WS8 6JZ.2. death.4 In the event of any breach of Electrium’s express obligations under clauses 7. whether or not such document is referred to in the Contract.2. where the breach is capable of remedy. strikes.3 Electrium will use reasonable endeavours to deliver each of the Customer’s orders for the Goods within the time agreed in accordance with clause 7. 16. indirect or consequential loss (all three of which terms include. be severed from the Contract and will be ineffective without. indirect or consequential loss (all three of which terms include. 3. 4.2 All pallets used shall remain at all times the property of Electrium and are to be returned to Electrium (at Electrium’s cost) on demand in good condition. Save as set out in the Contract.1 The place of delivery for Goods shall be the Customer’s premises or as otherwise agreed by Electrium in writing. expenses.3 Until ownership of the Goods has passed to the Customer. events.5. 10. execution or other process levied or enforced on any of its property.1. despite those endeavours. confirmation of order or similar document.2 If Electrium’s performance of its obligations under the Contract is affected by Force Majeure. 8. or to comply with the requirements referred to in clause 9.5. provided Electrium has not previously withdrawn it. topography rights and any other rights in any invention.6. unregistered trade marks. 13 TERMINATION 13. (b) within seven days of delivery in the event that the Goods do not comply with the Contract. Acceptance of delivery of the Goods will be deemed conclusive evidence of the Customer’s acceptance of these Terms and Conditions. nor (for the avoidance of doubt) will Electrium have any liability to the Customer for direct. and will deliver any repaired or replacement Goods to the Customer at Electrium’s own expense. or of some other right.9 On termination of the Contract.3 above the remedies of the Customer will be limited to damages. loss of profits. that sum will bear interest from the date of invoice until payment is made in full. extends or delays or purports to cancel.7 in that person’s own name and for that person’s own benefit. . 5. 15. If the Customer cancels the order in accordance with this Clause 7.2 and 10. database rights.1 Time for performance of all obligations of the Customer under the Contract is of the essence.3 First orders from overseas Customers should be accompanied by bank references to enable payment terms to be agreed. furnished or specified by the Customer).5 Electrium does not exclude its liability (if any) to the Customer: 10. license. damage or direct. know-how.1 to 10. firm or company whose order for the Goods is accepted by Electrium “Electrium” Electrium Sales Limited (Company Number 2226729) whose registered office is at Lichfield Road. deductions or withholdings of any nature. breakdown of plant or machinery. but the time of delivery will not be of the essence.2 Ownership of the Goods will not pass to the Customer until Electrium has received in full (in cash or cleared funds) all sums due to it in respect of: 8. breach of statutory duty. damages. Electrium is unable for any reason to fulfil any delivery or performance on the specified date. free of charge. shortage or loss in transit or any claim that the Goods delivered do not otherwise comply with the Contract unless the Customer shall have informed Electrium in writing or facsimile as follows: (a) within three days of delivery in the event of any damage. protest. unregistered design rights. to the extent required. They will not form part of the Contract and this is not a sale by sample. material or finishes of the Goods which: 9. 8. omissions or accidents beyond the reasonable contemplation and control of Electrium including. used or intended to be used therefor and the cost of labour and other overheads including a percentage in respect of profit.2 The time of delivery will be as agreed between the parties or if no such agreement has been reached will be within a reasonable time and the Company will be entitled to make delivery by instalments. agents or sub-contractors.7 If the cost to Electrium of performing its obligations under the Contract shall be increased or reduced by reason of the making or amendment after the date of its quotation of any law or of any other order. 10. Any quotation is valid for a period of 30 days from the date thereof provided that Electrium has not previously withdrawn the quotation. explosion.3 not destroy. discrepancy or shortage. pure economic loss.4 The Customer may resell the Goods before ownership has passed to it solely on the following conditions: 8. levies. 10. Any further information which may be required about the use for which any specific product has been designed and tested.4 maintain the Goods in satisfactory condition insured on Electrium’s behalf for their full price again all risks to the reasonable satisfaction of Electrium. pure economic loss. or of any product incorporating any of the Goods. pure economic loss. or 10.CONDITIONS OF SALE OF GOODS HOME 1 DEFINITIONS AND INTERPRETION In these Terms and Conditions the following expressions shall have the following meanings unless inconsistent with the context: “Business Day” any day other than a Saturday or Sunday or a public or bank holiday in England “Contract” any contract between Electrium and the Customer for the sale and purchase of the Goods formed in accordance with clause 2 “Contract Terms” The terms and conditions governing the Contract which are set out below “Customer” The person(s). take all reasonable steps to recover from the underwriters any loss or damage for which they may be liable. in each case in the United Kingdom and all other countries in the world and together with all renewals and extensions “Terms and Conditions” the standard terms and conditions of sale set out in this document together with any special terms agreed in writing between the Customer and Electrium. 12. VAT is calculated on the discounted value of the invoice and is not subject to settlement discount.3 then: 7. 10.8 Each of Electrium’s employees. fire.1 Electrium may invoice the Customer for the Goods on or at any time after delivery and subject to clause 3.4 Notwithstanding any Contract Term allowing the Customer credit.6. rule.4 The price for the Goods is based on the costs of materials. Where the Customer requires delivery next day a charge of £13. delegate.7 Except as set out in clauses 7.6. 15 GENERAL 15. would or might subsist in favour of the Customer. or at its option. 12 SAFETY 12.5 the equivalent of any of the above occurs to the Buyer under the jurisdiction to which the Buyer is subject. 16.3 Any Goods which have been replaced will belong to Electrium. misleading or breached. existence. act of God. Electrium will be deemed not to be in breach of this Contract.3 has any distraint. “Force Majeure” any cause preventing Electrium from performing any or all of its obligations which arises from or is attributable to acts. 3. repair. The parties agree to submit to that jurisdiction. 8. Payment made before the payment is due under this clause shall be subject to a settlement discount of 2.5. direct.5 Electrium reserves the right to amend the Contract price to take account of any variations in these costs or the imposition of any new taxes or duties resulting from whatever cause before delivery of the Goods. Electrium may cancel the Contract by notice in writing to the Customer so far as it relates to Goods not supplied or work not done at the date of the Force Majeure and such cancellation shall not give rise to any claims by the Customer. electrium. specifications and performance data are constantly changing. . Latest details can be obtained from Crabtree.co.uk Web: www. AB 1980 09/03 Printed in England.ELECTRIUM SALES LIMITED Lichfield Road Brownhills West Midlands WS8 6JZ England. eMail:
[email protected]@electrium.uk UK SALES Telephone: 01543 455020 Facsimile: 01543 455021 eMail: crabtree.co.co. Publication No.uk EXPORT SALES Telephone: +44 1543 455049 Facsimile: +44 1543 455048 eMail:
[email protected] DUBAI OFFICE Telephone: +971 4 2666403 Facsimile: +971 4 2668031 DUBLIN OFFICE Telephone: +353 1 8208047 Facsimile: +353 1 8208107 Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication.