Cpk

March 26, 2018 | Author: Mayank Patel | Category: Bearing (Mechanical), Pump, Machines, Building Engineering, Mechanical Engineering


Comments



Description

CPKProduct Introduction 0052 .10 / 02 - 18 G3 CPK Family Curves n =2900 rpm. Standardized Chemical Pumps n = 1450 rpm. 200 Designed to DIN 24256/ISO 2858/ISO 5199 200 300- 350- 400710 710 710 250-710 200-670 100 50-315 40-315 100 40-250 32-250 50-250 65-315 65-250 250-630 300630 100-315 80-315 80-400 100400 40 32-200 50-200 40-200 65-200 H(m) H (m) 30 25-200 80-200 100-200 40 200500 40 -315 20 50 -315 65 -315 125-400 150-400 200-400 80 -315 100-315 125315 25-160 32-160 50-160 40-160 65-160 300- 350500 500 32 -250 40 -250 50 -250 65 -250 80-250 32 -200 40 -200 50 -200 65 -200 80 -200 50 -160 65 -160 80 -160 100250 10 80-160 25 -200 25 -160 20 32 -160 40 -160 250400 300400 150-315 200-315 400504 350400 400506 250315 125250 150-250 30 350- 400630 630 250-500 50 80-250 100-250 50 150-500 200250 100-200 5 32-125 4 3 10 0.5 2 1 3 4 Q I/s 5 2 10 3 4 5 20 30 10 40 50 20 30 100 40 50 200 300 100 140 400 500 2 0.3 0.4 0.5 2 1 Q l /s 3 4 2 5 3 10 4 5 20 30 10 40 50 3 20 30 100 40 50 200 100 300 400 500 200 300 400 500 1000 2000 1000 3000 3 Qm / hr Q m /hr Materials CPK pumps can be offered in Cast Iron (G), Cast Steel (E) & Stainless Steel (C) metallurgy G CI Gr. FG260 CI Gr. FG260 CI Gr. FG260 CI Gr. FG260 45C8 Type 316 CI Gr. FG260 CI Gr. FG260 E C WCB WCB WCB CF 8 M 45C8 / Type 410 45C8 CI Gr. FG260 CI Gr. FG260 Applications CF 8 M CF 8 M CF 8 M CF 8 M AISI 329 TYPE 316 CI Gr. FG260 CI Gr. FG260 For handling aggressive organic & inorganic fluids in the chemical & petrochemical industries. These pumps are also used at Refinery off-sites, Paper & Pulp Industry, Food Industry, Sugar Industry, Seawater desalination plants, absorption plants in environmental engineering, Power stations etc. Design * Other executions available on request, depending upon application. Horizontal, radially split, volute casing pumps in back pullout design, fitted with a radial impeller, single entry, single stage & designed in accordance with DIN 24256/ISO 2858/ISO 5199. Manufactured in technical collaboration with KSB Aktiengesellschaft., Germany by : Fax (020) 2742 6000 (020) 2747 0890 (0422) 246 8232 (02551) 230254 (02426) 272043 Regd. Office : Mumbai - 126, Maker Chambers III, Nariman Point - 400 021. (022) 6658 8787 (022) 6658 8788 Zonal Offices : Chennai Kolkata Mumbai NOIDA - (044) 2235 2571-2, 2235 5673 (033) 2287 0473, 2290 0117 (022) 6658 8787 (0120) 254 1091-93, 254 1501-3 (044) 2235 2749 (033) 2287 0588 (022) 6658 8788 (0120) 255 0567 Branch Offices : • Ahmedabad - (079) 26579610 / 11 • Aurangabad - (0240) 2351440, 2342447 • Bangalore - (080) 23491806, 23493925 • Baroda - (0265) 2330532, 2333226 • Bhubaneswar - (0674) 2558497, 2553061 • Chandigarh - (0172) 2549021 • Hubli - (0836) 2232244 • Indore - (0731) 2529478 • Jaipur - (0141) 2224554, 2224904 • Jamshedpur - (0657) 2317129, 2317130 • Lucknow - (0522) 2635203, 2635597 • Nagpur - (0712) 2236889 • Pune - (020) 25431258 / 59 / 60 • Raipur - (0771) 4062556, 2583921 • Secunderabad - (040) 27001724, 27003696 Service Stations : Odhav NOIDA Howrah Chennai - Shed 22, G.V.M. Estate, Ahmedabad - 382 410. "KSB House" A- 96, Sector IV, 201 301. 142/1, Foreshore Road, Near Ramkrishnapur Launchghat - 711 101. No. 4 (old no. 18) Chakrapani Road, Guindy, 600 032. (079) 22900372 (0120) 2541091-93 (033) 26382909 (044) 22550704 CPK 25 CPK E 20 15 CPK C 10 5 0 -70 -40 0 40 80 120 160 200 240 280 320 350 240 280 Product temperature in ºC E m 40 - 200 Material G Pump Type 20 Material of construction Technical matter. Subject to change without notice. - Irrigation and Process Division, Mumbai-Pune Road, Pune - 411 018. - Power Projects Division, D - II Block, MIDC, Pune - 411 019. - Valves Division, 151, NSN Palayam Post, Mettupalayam Road - 641 031. - Water Pumps Division, Plot No E-3 & E-4, MIDC Sinnar, Malegaon, Dist. Nashik- 422 113. - Foundry Division, Ahmednagar - 413 704. Telephone No. (020) 2710 1000 (020) 2740 9100 (0422) 246 8222 (02551) 230252 / 53 / 55 / 56 (02426) 272534, 272528, 272074 Guindy House, 2nd Floor, 95, Anna Salai - 600 032. 30, Circus Avenue, 2nd Floor - 700 017. 126, Maker Chambers III, Nariman Point - 400 021 "KSB House", A-96, Sector IV, NOIDA 201 301, Dist. Gautam Budh Nagar, U. P. Materials C and E Designation KSB PUMPS LIMITED Works : Pimpri Chinchwad Coimbatore Sinnar Vambori Pressure and Temperature limits Max. Pump discharge pressure bar Volute Casing Casing Cover Impeller Impeller Nut Shaft Shaft Protection Sleeve Bearing Bracker Bearing Bracket Lantern Standard Material Execution * Mktg. Serv./10-10/5000 Mechanical seal Discharge nozzle size in mm Nom. Imp. dia in mm Operating Data Pump Sizes Capacity Head Disc. Pressure Temperature DN Q H P t 32 to 250 mm up to 1200 m3/hr up to 150 m up to 25 bar -70ºC to +350ºC Max. Pump discharge pressure bar Part Designation 15 10 5 0 -10 0 40 80 120 160 Product temperature in 0C 200 CPK Flanges according to ANSI B 16.5 class 150 & 300 Jack-bolts for easy dismantling Casing cover cooling or heating possible.0. intensively cooled ( `Y' stuffing box ) Pressure retaining parts safe design by computerised strength analysis and quality casting with corrosion allowance Casing and impeller wear rings CPK-G . depending on size) Gland packing subsequent fitment of standard mechanical seal is possible Constant level oiler guarantees constant lubrication of the bearings and control of oil level.No wear ring Heavy Bearing Bracket for intensive loading Impeller Nut with helicoil for protection of threads Heavy Bearing Bracket with cooling arrangement. Rotor and bearing rated for a shaft deflection below.500 operating hours.only casing wear ring CPK-E/C . Optional features Shaft sealing chamber. Mechanical Seal : Single balanced ( Double and Tandem seals also available ) .05 mm and a bearing life of more than 17. No contact with medium handled ( due to confined sealing gaskets ) hence no need for special material Standard units fast delivery and small stock of spare parts ensured Back pull-out design when dismantling the pump. Shaft Dry shaft. the casing can remain in the pipeline Volute with low radial forces ( double volute available.
Copyright © 2024 DOKUMEN.SITE Inc.