CDVI Centaur51 Poster Eng Web

March 16, 2018 | Author: Don Gowewey | Category: Access Control, Digital Video Recorder, Telecommunications, Technology, Electronic Engineering


Comments



Description

C ENtaur 5.1 s oftwarE E ditioNs INTEGRATED ACCESS CONTROL CS-AC-LITE-USB5 CS-AC-STD-USB5 CS-AC-PRO-USB5* CS-AC-ENT-USB5* STARTER PACk LITE 1 1 Yes Yes 512 16 16 - Standard Professional Enterprise 64 1 Yes Yes 64 1 Yes Yes 8,196 per site (524,544 max.) FREE** 1 4 Yes Yes 512 1 2 Yes 2 64 128 Yes Yes Yes Yes Yes Centaur will overcome any access control challenge Sites Serial Ports Dial Up connection TCP/IP connection Cards Controllers Doors 64 4 Yes Yes 16,384 per site (1,048,576 max.) 2,048 per site (131,072 max.) 32 per site (2,048 max.) (8,192 max.) 64 per site (4,096 max.) 256 per site (16,384 max.) 128 per site Yes 64 per site (4,096 max.) 512 per site (32,768 max.) 2048 per site (131,072 max.) Asset Management Why buy something that you already have? Keep track of your assets and save time and money. Find quickly who is in possession of your assets. A report can be generated and sent automatically via email. Guard Tour Feature Live interactive guard tour allows check point validation using card readers, input points (Motion sensors, key switches, or push buttons) or data collectors. Includes live alarms for time violations and intuitive exception reports. Biometric Integration Centaur is a powerful solution for areas requiring enhanced security by authenticating fingerprints. Capturing, managing and transferring biometric data is now effortless with world-renowned fingerprint readers such as CDVI’s DGID/W/US, L-1 (model 4G), Sagem and more. Centaur Integrated Access Control System Overview Elevator Control Elevator Cabs Floors per cab Floor groups DVR Module Visitor Management Parking Management Guard Tour Asset Management * Comes with a workstation license Yes 128 per site (8,192 max.) Yes 512 per site (32,768 max.) 64 128 per site (8,192 max.) 64 128 per site (8,192 max.) 64 128 per site (8,192 max.) Yes Yes Yes Yes Yes New Yes Yes Yes Yes Yes ** Yes Yes Yes Yes Yes FREE from our web site, www.cdvi.ca Security dongle NOT required Every Centaur edition includes a Centaur Server with an administration console, plus all these software modules: Visitor Management Centaur Visitor Management preserves a complete record of all visitor activities and keeps each visitor’s information for subsequent visits. Centaur Visitor Management will allow you to securely control the comings and goings of all visitors. Parking Management The Centaur Parking Management provides you with a real time parking activity monitor. It allows you to quickly see how many parking places are used, by which user and how many parking spaces are available. Video (DVR) Module Centaur video module (DVR) lets you playback up to 60 seconds before and after a specific event. It also lets you capture a video image (frame) during the playback or live camera viewing in jpeg format. 1645-A Highway 440 West, Laval, Quebec, Canada, H7L3W3 Tel.: (450) 682-7945, Toll Free Tel.: 1-866-610-0102, Fax: (450) 682-9590, Toll Free Fax: 1-866-682-9590 Pro-Report with Tracker: On demand, scheduled or customized reports FrontView: Live interactive floor plans FrontGuard: Display real-time visual authentication FrontDesk: Create, modify, delete and print cards, include Photo-ID Locator: Monitor real-time location of each card holder WavePlayer: Play a sound on any system event Workstation license (CS-WSLIC-USB5): Manufacturing Access Control since 1985 Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console and all software modules. E lECtroMagNEtiC l oCk or d oor s trikE o ptioN + + 2-d oor C oNtrollEr Ct-V900-a Transformater CDVI150 24 Vac, 75VA Also includes an output of 16 VAC (75 VA) that can power up to 3 2-door expansion modules CA-A470-A + CP - Thin card for printing (ISO) - + - + Fire alarm contact for Lock1 & Lock2 - Power Supply + - Connect earth terminal to a certified earth ground 2 batteries (12V, 7AH) connected in series for 24V backup CPE - Standard clamshell card + Lock Control Module (optional) CA-A110-P Connect directly to controller lock terminals R1/DO GND R1/D1 12V OUT1 OUT2 OUT5 GREEN BLACK WHITE RED YELLOW (green LED) ORANGE (red LED) BROWN (buzzer) Polycarbonate Proximity Reader DGLP FN WLC Power Supply + Always consult the regulatory agency in your area for existing regulations regarding doors designated as emergency exits. ! a larM s ouNdEr + pEr CoNtrollEr ) Blue (Clock) Not applicable with Centaur System R2/DO GND R2/D1 12V OUT3 OUT4 OUT6 DO D1 C oNtrollEr i Nputs Magnetic Door Contact (u p to 16 Request-to-Exit Button (EXIT-BLP) + V (green LED) R (red LED) B (buzzer) C oNtrollEr N Etwork (rs-485) Z1: 1K Ohm EOL 1K Ohm Optional Loop Supervision Z2: 2.2K Ohm H (Clock) Not applicable with Centaur System A2+ B2A1+ B1GND GND GND GND To next controller of a site. MODULE NETWORk (E-BUS RS-485) Furthest module can be installed up to 1220M (4000ft) away from the CT-V900-A controller Stainless Steel Proximity Reader DGLI WLC ! Reader wiring may differ from diagram. Please consult your documentation for details. Tamper Switch N.C. Contact s ErVEr to C oNtrollEr C oMMuNiCatioN CoNtrollEr N Etwork JuMpEr & dipswitCh s EttiNgs START POINT of the RS-485 controller network. (Furthest modules can be up to 1220m (4000ft) from start point) E- bus N Etwork CapaCity & ModulEs 1 Transformer 16 VAC, 40VA 50/60Hz Class 2 and 1 battery (12V, 7AH) per CA-A480-A & CA-A470-A SERVER RS-232 7.6m (25ft) max. CONVERTER SETTINGS EOL= ON POSITION CA-A360-A RECEIVE TRANSMIT POWER Optional Networked Workstation First controller of a site (CT-V900-A) Bias High/Low Jumpers A+= Low B-= Low At the START POINT and the END POINT of the RS-485 controller network, the devices’ EOL jumpers= ON. All devices‘ in between EOL= OFF CT-V900-A #1 Note: If you do not use a converter, the first CT-V900-A controller will be the START POINT. At the START POINT of the RS-485 controller network, the device HIGH/LOW Bias jumpers is set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH CT-V900-A CUT VIEW Elevator Controller CA-A480-A (Max. 8 per CT-V900-A) 2-Door Expansion Module CA-A470-A (Max. 3 per CT-V900-A) CONTROLLER #1 SETTINGS EOL= OFF Bias High/Low Jumpers A+= High B-= High Dipswitch Setting 9.6K/19.2K DEF/RUN ADD 16 ADD 32 ADD 1 ADD 2 ADD 4 ADD 8 ON GND TX RX GND BA+ GND +12V E-bus NEtwork JuMpEr & dipswitCh sEttiNgs CT-V900-A START POINT of the RS-485 E-bus network (Furthest module can be up to 1220m (4000ft) from start point) EOL= ON CT-V900-A 2-Door Controller CT-V900-A 2-Door Controller 1 2 3 4 5 6 7 8 OFF At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH CONTROLLER #2 SETTINGS EOL= OFF Bias High/Low Jumpers A+= High B-= High Dipswitch Setting 9.6K/19.2K DEF/RUN ADD 16 ADD 32 CT-V900-A #2 ADDRESSABLE DIPSWITCH Bias High/Low Jumpers A+= Low B-= Low LCD Display Relay Expansion Module CK-TRAK-L CA-A460-P (Max. 8 per CT-V900-A) (Max. 2 per CT-V900-A) USB/RS232 to RS-485 Converter CA-A360-USBRS CT-V900-A 2-Door Controller END POINT of the RS-485 E-bus network CA-A480-A E-BUS ADD 1 1 ADD 2 2 ADD 4 3 ADD 8 4 ON CA-A480-A E-BUS 5 6 7 8 OFF A+ BGND TAMPER TAMPER COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 A LOW HIGH B LOW HIGH EOL 350mA/700mA FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT DRM MODULE RL14 RL14 Elevator Controller CA - A480 - P STATUS FREE ACCESS COMM FAILURE BATT TROUBLE ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON RL11 ON 1 2 3 4 5 6 7 8 RL5 RL6 RL7 RL8 RL9 RL10 RL12 NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 DRM MODULE E-BUS RX TX AC AC BAT+ BAT+12V +12V GND GND FC FC A+ BGND TAMPER TAMPER COM1 NO1 NC1 COM2 NO2 NC2 COM3 NO3 NC3 COM4 NO4 NC4 A LOW HIGH B LOW HIGH EOL 350mA/700mA FC OVERIDE AC BATT REVERSED 12V +12V RELAY BATT E-BUS RX TX AC AC BAT+ BAT+12V +12V GND GND FC FC NC16 NO16 COM16 NC15 NO15 COM15 NC14 NO14 COM14 NC13 NO13 COM13 CA-A470-A CA-A470-A 2-Door Expansion Module LOCK#1 CA-A470-A CA-A470-A 2-Door Expansion Module LOCK#1 CONTROLLER NETWORK JUMPERS E-BUS NETWORK JUMPERS RL16 RL16 RL15 RL15 RL13 RL13 COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 COM9 NO9 NC9 COM10 NO10 NC10 COM11 NO11 NC11 COM12 NO12 NC12 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 COM5 NO5 NC5 COM6 NO6 NC6 COM7 NO7 NC7 COM8 NO8 NC8 SP +12V R2/KPD R2/KPC R2/KPB R2/KPA SP +12V R1/KPD R1/KPC R1/KPB R1/KPA SP +12V R2/KPD R2/KPC R2/KPB R2/KPA SP +12V R1/KPD R1/KPC R1/KPB R1/KPA R2/D1 R2/D0 R2/0V R2/+5V R1/D1 R1/D0 R1/0V R1/+5V R2/D1 R2/D0 R2/0V R2/+5V TX RX E-BUS R1/D1 R1/D0 R1/0V R1/+5V OUT4 OUT3 OUT2 OUT1 OUT4 OUT3 OUT2 OUT1 EOL= OFF Bias High/Low A+= High B-= High Dipswitch Setting RLY COMMS RLY OFF/ON ADDRESS 1 1 RL1 RL2 RL3 RL4 RL1 RL2 RL3 RL4 RL5 Elevator Controller CA - A480 - P STATUS FREE ACCESS COMM FAILURE BATT TROUBLE ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 RLY COMMS RLY OFF/ON DRM ENABLED PWR OFF/ON RL11 ON 1 2 3 4 5 6 7 8 RL6 RL7 RL8 RL9 RL10 RL12 D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 STATUS LOCK#2 JP120 350mA/700mA ON 1 2 3 4 5 6 7 8 1 + AC OK AUX OK COMM CHECK BATT BATT TRBL 4 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#1 DATA AC AC BAT+ BATV+ V+ VVOUT5 OUT6 LOW HIGH BA+ 2 5 READER#2 DATA A+ BGND EOL 3 TMP TMP D1NC COM D1NO D2NC COM D2NO Z1 COM Z2 Z3 COM Z4 STATUS LOCK#2 JP120 350mA/700mA ON 1 2 3 4 5 6 7 8 1 + AC OK AUX OK COMM CHECK BATT BATT TRBL 4 BACKUP 2 1 0 0 NO CARD 0 1 2 CARDS 1 0 ALL CARDS 1 1 UNLOCK DOOR SWITCH SW1 ADD 1 SW2 ADD 2 SW3 L1Energize SW4 L2Energize SW5 BACKUP1 SW6 BACKUP2 SW7 PULSE 5&6 SW8 N/D READER#1 DATA AC AC BAT+ BATV+ V+ VVOUT5 OUT6 CONTROLLER #3 SETTINGS EOL= ON Bias High/Low Jumpers A+= High B-= High Dipswitch Setting 9.6K/19.2K DEF/RUN ADD 16 ADD 32 ADD 1 ADD 2 ADD 4 ADD 8 LOW HIGH BA+ 2 5 READER#2 DATA A+ BGND EOL 3 TX RX E-BUS TMP TMP CT-V900-A #3 Example of Jumper Settings EOL Jumper set to EOL OFF EOL= OFF Bias High/Low A+= High B-= High Dipswitch Setting PWR OFF/ON RLY COMMS RLY OFF/ON ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 EOL= OFF Bias High/Low A+= High B-= High Dipswitch Setting PWR OFF/ON PULSE 5&6 L1 Energize L2 Energize BACKUP1 BACKUP2 ADD 1 ADD 2 EOL= ON Bias High/Low A+= High B-= High Dipswitch Setting PULSE 5&6 L1 Energize L2 Energize BACKUP1 BACKUP2 ADD 1 ADD 2 EOL Jumper set to EOL ON CT-V900-A 2-Door Controller Real-Time Clock Lithium Battery Setting ON OFF Jumper set to ON BATT ON OFF Jumper set to OFF BATT Jumper set to HIGH ON OFF HIGH LOW Jumper set to LOW Destination Reporting Module CA-A482-P The DRM connects directly to the CA-A480-A, elevator controller TCP/IP Module CA-ETHR-A RS-485 Network Hub CA-A370-P 1 2 3 4 5 6 7 8 DRM ENABLED DRM ENABLED ADDRESS 2 2 ADDRESS 4 3 ADDRESS 8 4 ON ON ON ON 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 OFF END POINT of the RS-485 controller network HIGH LOW N/D N/D All the specifications on this document (photos, drawing, features and dimensions) could be changed without prior notice. Printed in Canada - December 2008
Copyright © 2024 DOKUMEN.SITE Inc.