Catalog Frialit Xive

March 24, 2018 | Author: cdimis | Category: Dental Implant, Screw, Prosthesis, Medical Specialties, Medicine


Comments



Description

FRIALIT & XiVE® ® Catalog FRIALIT & XiVE ® ® ANKYLOS FRIOS ® ® PEPGEN P-15 ® FRIALIT & XiVE Catalog ® ® FRIALIT® & XiVE® – Two implant designs, one prosthesis! FRIALIT® – The root-analog implant with unlimited prosthetic options for ultimate esthetics. XiVE® – The implant design for accelerated treatment with highest primary stability in all bone qualities. Ultimate esthetics and accelerated treatment – the FRIALIT® and XiVE® implant options cover all indications. The identical implant-abutment-connection of FRIALIT® and XiVE® S implants provides a unique platform for the optimal realization of all prosthetic concepts using the components of FRIADENT® Prosthetics. FRIADENT Prosthetics ® XiVE TG Prosthetics ® XiVE® TG – The transgingival alternative. Single-stage transgingival XiVE® TG Screw Implants are available in addition to the subgingival implant design. The superstructure is produced with XiVE® TG prosthetic line components. FRIALIT Implants ® XiVE S Implants ® XiVE TG Implants ® Information regarding the materials involved in implants, system components and instruments is given in the form of a reference number after every article: FRIADENT® Gingiva Former2. Page 87 of this catalog presents an overview of the materials and the composition of the materials used. The pictures in this catalog are for illustration. The size of the illustrated products may deviate from the original product. DENTSPLY Friadent reserves the right to make any technical changes without prior notice. 2 Content FRIALIT® Implants Pre-surgical planning Implant placement Instruments for implant placement 4 6 9 12 20 22 24 28 38 42 XiVE® Implants Pre-surgical planning Implant placement Instruments for implant placement FRIADENT® Prosthetics Uncovery Fabrication of superstructure at implant level Soft tissue management, Provisional restorations Impression making Prosthetics/laboratory Fabrication of superstructure at gingival level (MP-Abutment) Transgingival extension, temporary sealing Impression making Prosthetics/laboratory Instruments for impression making/ prosthetics/laboratory 43 46 49 55 57 58 62 66 68 70 72 73 76 78 79 79 XiVE® TG Implants and Prosthetics Implant placement Instruments for implant placement Impression making Prosthetics/laboratory Instruments for impression making/ prosthetics/laboratory Presentation material Appendix Materials Additional DENTSPLY Friadent Product Catalogs Order No. 6-252004 for ANKYLOS® Order No. 6-302017 for FRIOS® and PEPGEN P-15® 3 Presentation material XiVE® TG FRIADENT® Prosthetics for FRIALIT & XiVE S ® ® XiVE® FRIALIT® FRIALIT ® FRIALIT® plus Implants – Prevention instead of intervention for perfect esthetics Innovative esthetic implant concepts should consider tooth-by-tooth replacement as early as possible. FRIALIT®, the first root-analog implant geometry in the world, offers perfect esthetics of peri-implant soft tissues, excellent prosthetic results and long-term success. Following nature’s design, FRIALIT® implants stepped design ensures an optimum transfer of occlusal forces. The anatomical diameters allow support of the alveolar bone, reconstruction of the interproximal space and maintenance of the papillae. Perforating the buccal plate or injuring converging roots during surgery can be avoided since the apical end of the implant is narrower. The implant-abutment connection provides the utmost in stability with long parallel-walled sections to resist lateral forces and a deep internal hex to prevent rotation. 4 Indications Cases: ■ where hard and soft tissue atrophy can be prevented through immediate or delayed-immediate implant placement ■ with high esthetic demands.8 Ȝ D 4.5 Ȝ D 5. Stepped screw implant with trimodal surface morphology providing an ideal environment for functional adaptation of epithelium. Micro-design The synchronized thread design of the FRIALIT® plus stepped screw offers increased self-tapping efficiency in cortical bone and optimum primary stability with secure retention in soft spongy bone – ideal in all bone qualities. supports peri-implant bone and overlying soft tissue. connective tissue and bone. particularly in the anterior region ■ requiring a natural “emergence profile” based on the crestal-anatomical implant diameter ■ where trauma to the labial or buccal wall or adjacent anatomical structures can be prevented by using rootanalog stepped implants ■ planned for tooth-by-tooth reconstruction Macro-design Root-analog. Nano-design Growth-activating FRIADENT® plus surface.5 Ȝ D 6.5 Ȝ Ȝ 5 FRIALIT® . Implant diameters D 3. stepped design provides functional transfer of occlusal forces.4 FRIALIT ® D 3. The interproximal space and the papillae are preserved based on the anatomy. 8/A 4. 3 pieces) 6 .4 and D 3.4 and D 3.8/A 15 angled Select Try-in Abutment – one FRIADENT® Select Sleeve and the pin – one FRIALIT® Select Try-in Implant – Implant Forceps – one Select Tray Try-in Abutments Gingival height.8/A 4.5/A 5. angled.4/A 3. 45 – 2190 FRIADENT ® Basic Set Select Try-in Abutment The Basic Set consists of a FRIADENT® Select Try-in Abutment A 0. Article FRIADENT ® Select Try-in Abutments and Sleeves can be used either for FRIALIT® or XiVE® implants. 3 pieces) 15 (angled 15°.8/A 0 (straight.4/A 3. The design of the Select Try-in Abutments has been adapted to the special implant geometries. 45 – 5020 FRIALIT® Select Basic Set Complete The Basic Set includes for each implant diameter – one straight FRIADENT® Select Try-in Abutment and the D 3. 3 pieces) 0 (straight.5/A 5.8/A 15. angulation and the correct position of the horizontal screw (GH 2) for FRIADENT® abutments can easily and quickly be determined with the FRIADENT® Select Try-in Abutments. 3 pieces) 15 (angled 15°.5/A 3. 3 pieces) 0 (straight. FRIADENT ® Select Try-in Abutment2 45 45 45 45 45 45 – – – – – – 2120 2121 2122 2123 2220 2221 – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD 3.4/A 3. Therefore. straight for each implant diameter and the FRIADENT® Select Try-in Abutments D 3. different Try-in Implants (FRIALIT® or XiVE®) have to be used for FRIALIT® and XiVE®.8/A 0 (straight) 0 (straight) 0 (straight) 0 (straight) 15 (angled 15°) 15 (angled 15°) FRIADENT ® Select Multipack Try-in Abutment (3 pieces) 45 45 45 45 45 45 – – – – – – 2193 2194 2195 2196 2293 2294 – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD 3.Pre-surgical planning Order No.5/A 3.4/A 3. 3 pieces) 0 (straight. 5 FRIALIT ® Multipack Select Try-in Implant (3 pieces) 45 45 45 45 45 – – – – – 5085 5081 5082 5083 5084 – – – – – ȜD ȜD ȜD ȜD ȜD 3.5 6.8 4. implant axis and the implant position in relation to the bone crest during surgery. without pin) 45 45 45 45 45 – – – – – 5095 5091 5092 5093 5094 – – – – – ȜD ȜD ȜD ȜD ȜD 3.4 3.8 4.5 5. 45 – 5090 FRIADENT® Select Basic Set Sleeve The Basic Set contains one pin and one FRIADENT® Select Sleeve per implant diameter.4 3.5 FRIADENT ® Multipack Select Sleeve (3 pieces.5 5.5 (3 (3 (3 (3 (3 pieces) pieces) pieces) pieces) pieces) 91 – 4502 FRIADENT ® Khoury Drill Guide Pin2 Try-in Implants With FRIALIT® Select Try-in Implants you can verify implant position. 45 – 5080 FRIALIT ® Select Basic Set Try-in Implant The Basic Set contains one FRIALIT® Select Try-in Implant per implant diameter.5 5.8 4. FRIADENT ® Select Sleeve2 without pin 45 45 45 45 45 – – – – – 5035 5045 5055 5065 5075 – – – – – ȜD ȜD ȜD ȜD ȜD 3. Sleeves Article FRIADENT® Select Sleeves allow for an exact transfer of the pre-prosthetic planning to the clinical situation.8 4.Order No.5 6. FRIALIT ® Select Try-in Implant2 45 45 45 45 45 – – – – – 5030 5040 5050 5060 5070 – – – – – ȜD ȜD ȜD ȜD ȜD 3. The thickness of the the soft tissue can be measured.5 5.5 6.5 6.4 3.4 3.5 (3 (3 (3 (3 (3 pieces) pieces) pieces) pieces) pieces) 7 FRIALIT® . 1. 48 – 0040 Article FRIALIT ® Select Tray (empty) Others 49 – 1211 FRIADENT ® Radiographic Balls for pre-surgical planning6 (Ø 5 mm).3 :1. 1.7 :1) 45 – 5570 8 .Pre-surgical planning Order No. quantity: 12 FRIALIT ® Radiographic Template (Scales 1:1. The blister is also non-sterile. ■ ■ ■ FRIADENT® sterile packaging for FRIALIT® Screw Implants 2. Insert the FRIALIT® implant dependent on the implant type.Implant placement FRIADENT® sterile packaging for implants All FRIADENT® implants are packed in gamma sterilized. Cover screw Retaining stopper Stepped screw with placement head Polycarbonate inner vial (sterile) Outer vial (non-sterile) The Cover Screw of FRIALIT® Stepped Cylinders is already in the implant. The undamaged label clearly indicates that the sterile package has not been opened and thus product sterility. sealed transparent double vials. Please follow the instructions for use. ■ No-touch insertion FRIALIT® implants 1. Remove the implant via the silicone stopper without touching the inner vial. An adhesive label seals the color-coded cap with the non-sterile outer vial. Color-coded cap matching the implant diameter 3. 9 FRIALIT® . Remove the cap from the outer vial (non-sterile) Transparent outer vial – to see the content Color-coded cap displaying the implant length – for clear identification Sterile inner vial with implant retaining stopper – for fast and safe no-touch placement of implants Peel-off labels – for a reliable documentation and slide the inner vial (sterile) onto the surgical tray. 10 . The Cover Screws are seated in with the 0.5/L 4.5/L 82 10 2 13 2 15 2 82 10 2 13 2 15 2 36 – 0471 36 – 0473 36 – 0475 – Ȝ D 6.5 5.5/L 5.5 11 FRIALIT® . FRIADENT ® Cover Screw for Implants2 45 45 45 45 45 – – – – – 1130 1140 1150 1160 1170 – – – – – ȜD ȜD ȜD ȜD ȜD 3. use the FRIALIT® Stepped Screw Implant Driver for ratchet or handpiece (see page 18).Implant placement Order No. To complete the insertion.9 mm FRIADENT® Hex Driver. Article Implants (sterile) FRIALIT ® plus Stepped Screw Content: Stepped Screw.5/L 13 2 – Ȝ D 6. the Placement Head is removed with the 0.5/L 5.8 4.5/L 15 2 Before rotating the FRIALIT® Screw Implant into place. The Cover Screw for FRIALIT® Stepped Screw Implants is located in the silicone stopper of the inner vial.9 mm FRIADENT® Hex Driver or with the blade width 2.8/L 15 2 – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD 4.8/L 13 2 – Ȝ D 3.4/L 13 3 – Ȝ D 3. Placement Head2 and Cover Screw2 36 – 0431 36 – 0433 36 – 0435 36 – 0441 36 – 0443 36 – 0445 36 36 36 36 36 36 36 36 – – – – – – – – 0450 0451 0453 0455 0460 0461 0463 0465 – Ȝ D 3.5/L 4.5/L 5.5/L 5.5/L 10 2 – Ȝ D 6.4/L 15 3 – Ȝ D 3.4 3.4/L 11 3 – Ȝ D 3.5 6.8/L 11 2 – Ȝ D 3.0 mm FRIADENT® Screwdriver.5/L 4. 4 FRIALIT® Twist Drill D 2.Instruments for implant placement The FRIALIT® drill sequence A successful implant placement requires precise and careful implant site preparation.4 FRIALIT® Stepped Cylinder D 3.8 FRIALIT® Stepped Screw D 4.5 FRIALIT® Stepped Screw D 5. ® FRIALIT® Stepped Screw D 6.5 FRIALIT® Stepped Cylinder D 6.5 FRIALIT BoneCondenser In cases of poor bone quality.0 FRIALIT® Round Drill FRIALIT® Stepped Drill D 3. The FRIALIT® Cortical Drill gently expands the implant site as required by increasing the diameter of the first step by 1/10 mm and thus allows for an easy and atraumatic implant insertion avoiding a too high insertion torque.5 12 . FRIALIT® BoneCondensers can be used for lateral and apical implant site condensation. FRIALIT® Twist Drills and Stepped Drills FRIALIT® Twist Drills and Stepped Drills are used at 800 rpm. Therefore.5 mm stepped drills are used at a maximum speed of 400 to 500 rpm.8 FRIALIT® Stepped Cylinder D 3. In very dense cortical bone the diameter 5. please follow our recommendations for drilling exactly. FRIALIT® Stepped Screw D 3.4 FRIALIT® Stepped Screw D 3.5 mm and 6.5 FRIALIT® Stepped Cylinder D 4. Additional preparation of the top step with the FRIALIT® Cortical Drill can compensate for this effect. FRIALIT® Cortical Drill Dense cortical bone (type I bone) frequently exhibits elastic forces after implant site preparation.5 FRIALIT® Stepped Cylinder D 5. This improvement of bone quality and quantity enhances primary implant stabilization. During the preparation make sure drills are adequately internally and externally irrigated. 5 FRIALIT® Stepped Drill D 5.FRIALIT® Stepped Drill D 3.5 Cortical Drill D 6.5 Cortical Drill D 5.5 Cortical Drill D 4.5 For type I bone 13 FRIALIT® .5 FRIALIT® Stepped Drill D 6.8 FRIALIT® Stepped Drill D 4.8 Cortical Drill D 3. ) FRIALIT® Select Try-in Implant StarterSet FRIALIT Select Try-in Implant D 3.5/L 15 Cortical Drill D Cortical Drill D Cortical Drill D Cortical Drill D 3.Instruments for implant placement Order No.5/L 13 Stepped Drill D 6.8 universal (with 4 Depth Stops) Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D Stepped Drill D 4.5/L 10 Stepped Drill D 6.4 FRIADENT® Select Try-in Abutment D 3.5 5.5/L 5.9 mm Handpiece Slot Screwdriver Ratchet Slot Screwdriver Implant Forceps Surgical Tray StarterSet ExpertSet ■ ■ ■ ■ ■ ■ ■ ■ ■ FRIADENT® Select Try-in Abutment StarterSet FRIADENT® Select Try-in Abutment D 3.5/L 5.5/L 4. The kits are supplied in the new FRIALIT Surgical Tray. Article FRIALIT Sets Surgical Instruments The instrument sets contain all instruments required for implant placement.4 Ratchet Stepped Screw Implant Driver – 12 mm – 16 mm – 20 mm FRIADENT Ratchet FRIADENT Ratchet Insert for Implant Driver Seating Instrument for Cylinder Implants standard Seating Instrument for Cylinder Implants posterior Handpiece Hex Driver 0. 45 – 8072 45 – 8090 FRIALIT Basic Set Surgery FRIALIT Expert Set Surgery Contents: Radiographic Balls for pre-surgical planning (5 pcs.5 Handpiece Stepped Screw Implant Driver D 3.5 Drill Extension Long Internal Irrigation Tube Drill Cleaning Instrument ■ 14 .5/L 4.4/A 15 (angled 15°) Fitting Tool for Depth Stops Depth Gauge D 2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Twist Drill D 2 (with 4 Depth Stops) ■ Stepped Drill D 3.5/L 4.5 6.5/L 5.9 mm Ratchet Hex Driver 0.5/L 8 10 13 15 8 10 13 15 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Stepped Drill D 6.4 (with 5 Depth Stops) ■ Round Drill ■ Stepped Drill D 3.8 4.4 ® StarterSet ExpertSet Contents: Handpiece Stepped Screw Implant Driver D 3.8 – D 6.5/L 5. 15 FRIALIT® .4 universal (with 5 Depth Stops) – Ȝ D 3.5/L 5.5/L 4.5/L 4.5/L 5.5/L 13 – Ȝ D 6.8 universal (with 4 Depth Stops) – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD 4.5/L 5.8 4.5 5.5/L 8 10 13 15 8 10 13 15 45 – 5371 45 – 5373 45 – 5375 45 – 5101 – Ȝ D 6.Order No.5/L 15 FRIALIT® Drill Depth Stop Tool6 (two-piece) FRIALIT® Cortical Drill6 45 45 45 45 – – – – 5349 5359 5369 5379 – – – – ȜD ȜD ȜD ȜD 3. 45 – 5102 45 – 5130 FRIALIT® Twist Drill D 26 (with 4 Depth Stops) FRIALIT® Round Drill6 FRIALIT® Stepped Drill6 45 – 5331 45 – 5340 45 45 45 45 45 45 45 45 – – – – – – – – 5350 5351 5353 5355 5360 5361 5363 5365 – Ȝ D 3.5 6.5 The FRIALIT® Cortical Drill is used to prepare the coronal section of the implant site in very dense cortical bone. 45 – 5280 91 – 0003 90 – 5042 90 – 5043 FRIADENT® Drill Cleaning Instrument6 FRIADENT® Drill Extension6 FRIOS® Contra-angle Handpiece 20:1 Irrigation Tube Long Internal Irrigation Tube (for Drill Extension) The drill extension must always be used with the long internal irrigation tube.5/L 4.5/L 5.5/L 10 – Ȝ D 6. Please replace the cutting instruments after approximately 20 uses or if they are damaged or dull. Drills6 Article All FRIALIT® Drills are provided with internal irrigation. 5 /L 15 FRIALIT® Instrument Set BoneCondenser.8 – D 5. The improved bone quality and quantity increases implant primary stability.5 (surgical tray with six instruments) Ȝ Ȝ Ȝ Instruments Set for diameter D 3. FRIALIT Instrument Set BoneCondenser.5 /L 15 – Ȝ D 5.5 /L 13 – Ȝ D 5. Article FRIALIT BoneCondenser FRIALIT® BoneCondenser can be used in reduced bone quality to condense the lateral and apical bone of the implant site.8 – Ȝ D 4.5 (surgical tray with twelve instruments) FRIALIT® BoneCondenser.5 (surgical tray with nine instruments) Ȝ Ȝ Ȝ Ȝ Instruments Set for diameter D 3. straight25/6 45 – 5402 45 – 5403 45 – 5440 45 – 5451 45 – 5453 45 – 5455 45 – 5461 45 – 5463 45 – 5465 45 – 5471 45 – 5473 45 – 5475 – Ț D 2.8 – D 6.5 (surgical tray with six instruments) Ȝ Ȝ Ȝ Instruments Set for diameter D 3.5 /L 15 – Ȝ D 6.8 – D 4.5 (surgical tray with twelve instruments) 16 .5 /L 10 – Ȝ D 4.8 – D 4.5 /L 10 – Ȝ D 5.8 – D 6.0 – Ȝ D 3.5 /L 13 – Ȝ D 6.Instruments for implant placement Order No.0 – Ț D 3. angled with tray 45 – 8950 45 – 8960 45 – 8970 Ȝ Ȝ Instruments Set for diameter D 3.5 /L 13 – Ȝ D 4.5 /L 10 – Ȝ D 6. straight with tray 45 – 8550 45 – 8560 45 – 8570 Ȝ Ȝ Instruments Set for diameter D 3.8 – D 5.5 (surgical tray with nine instruments) Ȝ Ȝ Ȝ Ȝ Instruments Set for diameter D 3. 48 – 0060 FRIALIT® BoneCondenser Tray5/6/26 (empty) FRIALIT® BoneExpander FRIALIT® BoneExpander are used for the local expansion of the narrow atrophied jaw.0 – Ț D 3.5 /L 15 FRIALIT® BoneExpander Tray5/6/26 (empty) 17 FRIALIT® .0 – Ȝ D 3. 45 – 8870 FRIALIT® Instrument Set BoneExpander with tray Ȝ Ȝ Ȝ Ȝ Instruments Set for diameter D 3.5 /L 15 – Ȝ D 5.5 /L 13 – Ȝ D 6.5 /L 13 – Ȝ D 4.5 /L 10 – Ȝ D 5.5 /L 15 – Ȝ D 6.8 – Ȝ D 4.Order No.0 – Ț D 3.8 – Ȝ D 4.8 – D 6.5 /L 13 – Ȝ D 6.5 /L 15 – Ȝ D 5. angled25/6 45 – 5902 45 – 5903 45 – 5940 45 – 5951 45 – 5953 45 – 5955 45 – 5961 45 – 5963 45 – 5965 45 – 5971 45 – 5973 45 – 5975 – Ț D 2.5 /L 10 – Ȝ D 4.5 (surgical tray with twelve instruments) FRIALIT® BoneExpander25/6 45 – 5802 45 – 5803 45 – 5840 45 – 5851 45 – 5853 45 – 5855 45 – 5861 45 – 5863 45 – 5865 45 – 5871 45 – 5873 45 – 5875 48 – 0050 – Ț D 2.5 /L 10 – Ȝ D 6.5 /L 13 – Ȝ D 5.5 /L 15 The angled FRIALIT® BoneCondenser are used when limited space is available and for the posterior region. Article FRIALIT® BoneCondenser.5 /L 10 – Ȝ D 4.5 /L 15 – Ȝ D 6.5 /L 13 – Ȝ D 4.0 – Ȝ D 3.5 /L 13 – Ȝ D 5.5 /L 10 – Ȝ D 5.5 /L 10 – Ȝ D 6. without inserts FRIADENT® Ratchet Insert for Implant Driver6 FRIALIT® Ratchet Stepped Screw Implant Driver6 – 12 mm – 16 mm – 20 mm FRIALIT® Handpiece Stepped Screw Implant Driver4 – Ȝ for D 3. narrow) – P 3 (angled.0 – D 3. Article FRIADENT® Periotome The FRIADENT Periotome is ideally designed for atraumatic residual root and tooth removal. wide) – P 2 (straight.0 18 .4 – Ȝ Ȝ Ȝ Ȝ for D 3. 45 – 5500 FRIADENT® Periotome Handle6 FRIADENT® Periotome Blade6 45 – 5501 45 – 5502 45 – 5503 – P 1 (straight.8 – D 6. narrow) Other instruments 45 – 5106 45 – 5709 45 – 5711 FRIADENT® Paralleling Pin2 FRIADENT® Ratchet6.5 46 – 5512 46 – 5516 46 – 5520 45 – 5519 45 – 5510 45 – 5104 45 – 5100 FRIADENT® Depth Gauge2 – D 2.Instruments for implant placement Order No. 5 5.8 4.9 mm/14 Ncm/short – width 0.5 19 FRIALIT® .4 3.0 mm/14 Ncm/short – blade width 2.Order No.9 mm FRIADENT® Handpiece Slot Screwdriver6 – blade width 2.22 mm/24 Ncm/long FRIADENT® Ratchet Slot Screwdriver6 with torque limit – blade width 2.9 mm 45 – 5651 45 – 5640 45 45 45 45 – – – – 5732 5733 5734 5736 45 – 5714 45 – 5722 45 – 5650 The 0. Article FRIADENT® Handpiece Hex Driver6 – width 0.5 6. 91 – 4510 91 – 4515 FRIADENT® Implant Mallet6/20 FRIADENT® Implant Forceps2 (titanium) FRIALIT® Trephine Drill6 45 45 45 45 45 – – – – – 5654 5655 5656 5657 5658 – – – – – ȜD ȜD ȜD ȜD ȜD 3.0 mm FRIADENT® Ratchet Hex Driver6 with torque limit – width 0.22 mm/24 Ncm/short – width 1.9 mm/14 Ncm/long – width 1.0 mm/14 Ncm/long FRIADENT® Hex Driver6 without torque limit – width 0.9 mm FRIADENT® Hex Driver without torque limit is recommended for regions with limited access. XiVE ® XiVE® plus Implants – As simple as possible. XiVE® cylindrical screw implants combine increased primary stability in all types of bone with a standardized prosthetic platform including the option of immediate loading. is fully compatible with the prosthetic components and instruments of FRIALIT®. which has been proven for over 10 years. Through its thread design and simplified surgical procedure. The XiVE® implants offer an accelerated procedure with multiple prosthetic options without requiring expensive and complicated surgical and laboratory techniques. XiVE® offers an implant for all types of bone. faster and as easy as possible for your patients. This universal prosthetic platform technology greatly simplifies life for the restorative dentist. 20 . The internal implant-abutment connection. as flexible as necessary The goal of implant dentistry is to make treatment simpler. connective tissue and bone.Indications Cases: ■ with atrophied ridges where augmentation is not desired or indicated ■ multiple implant restorations in posterior regions ■ where a cylindrical implant design is advantageous – particularly in the lateral region ■ where a subgingival and/or a transgingival implant design is indicated ■ with limited interproximal space: narrowest implant diameter = 3.4 Ȝ Ȝ D 3. even in spongy bone.0 mm ■ where the local bone must be used to the maximum possible extent: implant lengths available range from 8 to 18 mm ■ requiring increased primary stability for early or immediate implant function ■ when temporary and definitive components are needed for simple and fast prosthetic restoration Macro-design The cylinder-shaped design for internal condensation of the peri-implant bone prevents trauma and increases primary stability of implants.0 XiVE® S XiVE TG ® D 3.5 Ȝ Ȝ D 5. Implant diameters D 3.8 Ȝ Ȝ D 4. Nano-design Growth-activating FRIADENT® plus surface. Screw implant with trimodal surface morphology providing an ideal environment for functional adaptation of epithelium. Micro-design The innovative thread design of XiVE® screw implants combined with the bone-class-specific preparation of the implant site provides torque stabilization in all bone qualities.5 Ȝ Ȝ 21 XiVE® TG Article overview XiVE® TG see page 66 XiVE® . FRIADENT® Select Try-in Abutments2 45 45 45 45 45 45 45 45 – – – – – – – – 2119 2120 2121 2122 2123 2219 2220 2221 – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD 3.8 4.0/A 3.Pre-surgical planning Order No. Article Try-in Abutments Gingival height.4/A 3.4/A 3.5 5.4 3. FRIADENT® Select Sleeves2 without pin 45 45 45 45 45 – – – – – 5025 5035 5045 5055 5065 – – – – – ȜD ȜD ȜD ȜD ȜD 3.5/A 5. angle and the correct position of the horizontal screw (GH 2) for FRIADENT® abutments can easily and quickly be determined with the FRIADENT® Select Try-in Abutments.8/A 0 (straight) 0 (straight) 0 (straight) 0 (straight) 0 (straight) 15 (angled 15°) 15 (angled 15°) 15 (angled 15°) Sleeves FRIADENT® Select Sleeves allow for an exact transfer of the pre-prosthetic planning to the clinical situation.0 3.5/A 3.8/A 4.5 91 – 4502 FRIADENT® Khoury Drill Guide Pin2 22 .0/A 3. 5 Others 49 – 1211 26 – 9020 25 – 5206 FRIADENT® Radiographic Balls for pre-surgical planning6 (Ø 5 mm).5).8 4.0 XiVE® Select Basic Set Try-in Implant The Basic Set contains one XiVE® Select Try-in Implant per implant diameter (D 3. . implant axis and the implant position in relation to the bone crest during surgery. The thickness of the soft tissue can be measured.4 3. 12 pieces XiVE® Radiographic Template (subgingival) XiVE® TG Radiographic Template (transgingival) 23 XiVE® With XiVE® Select Try-in Implants you can verify implant position.5 5. Try-in Implants Article 26 – 1510 26 – 1500 XiVE® Depth Gauge2 D 2.0 3.Order No. XiVE® Select Try-in Implant2 26 26 26 26 26 – – – – – 1520 1530 1540 1550 1560 – – – – – ȜD ȜD ȜD ȜD ȜD 3.0 – D 5. 24 . 6. By doing so. 2.4/TempBase into the internal hex of the FRIADENT® TempBase. Please follow the instructions for use. Remove the outer vial cap (non sterile) and drop the sterile inner vial onto the surgical tray. Transparent outer vial – to see the content Color-coded cap displaying the implant length – for clear identification Sterile inner vial with implant retaining stopper – for fast and safe no-touch placement of implants Peel-off labels – for a reliable documentation ■ ■ ■ FRIADENT® sterile packaging for XiVE® S plus Screw Implants Retaining stopper: contains implant cover screw Implant holder Inner vial (sterile): contains implant and TempBase (pre-mounted to implant) Outer vial (non-sterile) 5.Implant placement FRIADENT® sterile packaging for screw implants All FRIADENT® screw implants are packaged in gammasterilized. Place the XiVE® Ratchet or Handpiece Implant Driver D 3. ■ No-touch insertion XiVE® S plus Screw Implant 1. Remove the implant without touching the inner vial. 25 XiVE® . sealed transparent double vials with colorcoded caps. The implant cover screw is located in the silicone stopper of the inner vial. the implant holder falls apart in two halves. 4. Remove the silicone stopper from the inner vial. The undamaged label clearly indicates that the sterile package has not been opened and thus product sterility. Insert the XiVE® S plus Screw Implant. 3. 0/L 11 – Ȝ D 3.8/L 3. The Cover Screw for XiVE® S Screw Implants is located in the silicone stopper of the inner vial.5/L 4.9 mm FRIADENT® Hex Driver. the TempBase Retaining Screw is loosened with the 0.8/L 3. The Cover Screws are threaded in with the 0.5/L 5.5 11 13 15 All XiVE® S Screw Implants are packaged with the FRIADENT® TempBase for mounting the implant driver.4/L 3. Then the TempBase removed. To rotate the XiVE® S Screw Implant into place. Once the implant is seated.4/L 3.4/L 3.8/L 3.0/L 13 – Ȝ D 3. TempBase2.4/L 3. Article Implants (sterile) XiVE® S plus Screw Implant Content: Screw Implant2.4/L 3. Cover Screw2 26 – 1422 26 – 1423 26 – 1425 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 – – – – – – – – – – – – – – – – – – – – – – 1431 1432 1433 1435 1438 1440 1441 1442 1443 1445 1448 1450 1451 1452 1453 1455 1458 1460 1461 1462 1463 1465 – Ȝ D 3.5/L 4.8/L 3.5/L 5.5 11 13 15 18 8 9. 26 .5/L 4.5/L 4.5/L 5. use the XiVE® Driver for Ratchet or Handpiece (see page 36).0/L 15 – – – – – – – – – – – – – – – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD 3.5 11 13 15 18 8 9.5/L 5.9 mm FRIADENT® Hex Driver.8/L 4.Implant placement Order No.5/L 5.8/L 3.5/L 4.5 11 13 15 18 8 9.5/L 9. .8 4 4. Article FRIADENT® TempBase In addition.0 – Ȝ Ȝ Ȝ Ȝ D 3.5 5.Order No.4 3.8 – Ȝ D 4.5 4 5.0 4 3. It is included in the XiVE® S plus Screw Implant.8 4.4 4 3.5 FRIADENT® Cover Screw for Implants2 45 45 45 45 45 – – – – – 1120 1130 1140 1150 1160 – – – – – ȜD ȜD ȜD ȜD ȜD 3.4 – D 5.5 4 FRIADENT® TempBase Cap28 46 – 1235 46 – 1255 46 – 1265 – Ȝ Ȝ Ȝ D 3. FRIADENT® TempBase with Retaining Screw TempBase 46 46 46 46 46 – – – – – 1220 1230 1240 1250 1260 – – – – – ȜD ȜD ȜD ȜD ȜD 3.5 – Ȝ D 5.0 and D 3. with the FRIADENT® TempBase Cap (please order separately) the TempBase can be used for ■ an immediate registration to fabricate a temporary during the healing period ■ an immediate provisional restoration (single tooth or multiple implant provisional).5 27 XiVE® The FRIADENT® TempBase serves as implant holder and placement head.5 FRIADENT® Retaining Screw TempBase4 46 – 1279 46 – 1280 – Ȝ D 3.0 3. The XiVE® Tap can be used to reduce the crestal torque achieved during insertion of implants. Bone D I – D III: up to 6 mm Bone D IV: 2 mm Pre-tapping the implant site in type I bone Pre-tapping the implant thread: In very cortical bone. 28 .4 ® ® XiVE S plus and XiVE TG plus all implants D 3. starting with D 3.5 mm XiVE S plus and XiVE TG plus all implants D 4. Pilot hole: XiVE® D 2.0 ® XiVE Twist Drill posterior or anterior D 2.8 ® ® Twist Drill posterior XiVE® TG L 13 XiVE® S L 13 0.0 Twist Drill (posterior or anterior) XiVE® Twist Drills and Twist Drills crestal are used at 800 rpm. please follow our recommendations for drilling exactly. Optimum flow volume is guaranteed if separate sources are used for internal and external irrigation. Marking: XiVE® Round Drill Preparation of the implant site: XiVE® Twist Drill (posterior or anterior). Twist Drill anterior 18 mm 15 mm 13 mm 11 mm 9. an optimal primary stability of the implant in all types of bone is achieved. pre-tapping of the implant site at 15 rpm is required in the crestal area after the initial 6 mm deep preparation. Therefore.5 ® ® XiVE S plus all implants D 5.5 ® Crestal depth preparation Crestal preparation to achieve the internal condensation effect: XiVE® Twist Drill crestal 2 mm 6 mm The crestal drilling varies between 2 and 6 mm based on the bone quality.Instruments for implant placement The XiVE® drill sequence A successful implant placement requires precise and careful implant site preparation. During the preparation make sure drills are adequately internally and externally irrigated.0 and increasing in diameter until the final implant diameter is reached.0 ® XiVE Round Drill ® XiVE S plus and XiVE TG plus all implants D 3.5 mm 8 mm XiVE S plus all implants D 3. Thus. 5 ® XiVE Twist Drill posterior or anterior D 5.5 ® XiVE Twist Drill crestal D 5.5 ® XiVE Tap D 5.5 ® XiVE® BoneCondenser: In cases of poor bone quality.4 ® XiVE Tap D 3.4 ® XiVE Twist Drill crestal D 3. XiVE® BoneCondensers can be used for lateral and apical implant site condensation.For type I bone XiVE Twist Drill posterior or anterior D 3.8 ® XiVE Twist Drill crestal D 3.0 ® XiVE Tap D 3.5 ® XiVE Tap D 4. 29 XiVE® XiVE Twist Drill crestal D 3.8 ® XiVE Twist Drill posterior or anterior D 4. This improvement of bone quality and quantity enhances primary implant stabilization.4 ® XiVE Twist Drill posterior or anterior D 3.8 ® XiVE Tap D 3.0 ® .5 ® XiVE Twist Drill crestal D 4.0 ® XiVE Twist Drill posterior or anterior D 3. 4 3.8 4.4/L 3.0/L 3.4 1 Handpiece Implant Driver posterior for Screw Implants D 3.8/A 0 FRIADENT® Select Try-in Abutment D 4.5 1 1 1 1 1 1 1 1 Ratchet Implant Driver posterior for Screw Implants D 3.5/L 8–15 8–15 8–15 8–15 8–15 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3.5 1 Ratchet Implant Driver anterior for Screw Implants D 3.0/L 8–15 Twist Drill anterior D 2.4 1 Handpiece Implant Driver anterior for Screw Implants D 3.4/A 0 FRIADENT® Select Try-in Abutment D 3.0/L 3.5 1 Handpiece Implant Driver anterior for Screw Implants D 3.0 1 Ratchet Implant Driver anterior for Screw Implants and TempBase D 3.9 mm/long Handpiece Hex Driver 1.Instruments for implant placement Order No.4/A 15 FRIADENT® Select Try-in Abutment D 3.0 1 Ratchet Implant Driver posterior for Screw Implants and TempBase D 3.8/L 4.5 5.8–D 6.5/L 5.0 1 Handpiece Implant Driver posterior for Screw Implants and TempBase D 3.0 3.22 mm/long Implant Forceps XiVE® Surgical Tray 1 1 1 1 1 1 1 1 1 1 1 1 1 Twist Drill posterior D 2.5/A 0 FRIADENT® Select Try-in Abutment D 5.4–D 6. The kits are supplied in the XiVE® Surgical Tray.8–D 6.5/L 8–18 8–18 8–18 8–18 8–18 3.5/A 0 FRIADENT® Select Try-in Abutment D 3.5 30 .0/A 0 FRIADENT® Select Try-in Abutment D 3.9 mm/short Handpiece Hex Driver 0. 26 – 8000 26 – 8005 Contents: Radiographic Balls for pre-surgical planning XiVE S Radiographic template XiVE® TG Radiographic template ® XiVE® Expert Set Surgery XiVE® Standard Set Surgery Expert Standard Set Set 5 1 1 1 1 1 1 1 1 1 1 3 5 1 1 – – – – – – – – 3 – – – – – 1 – 1 1 1 1 1 1 – – – – – 1 1 1 1 1 1 1 Contents: Long Internal Irrigation Tube Drill Cleaning Instrument Expert Standard Set Set 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FRIADENT Select Try-in Abutment D 3.0 1 Handpiece Implant Driver anterior for Screw Implants and TempBase D 3.8/A 15 ® Depth Gauge D 2.0 3.5 1 Ratchet Implant Driver TG 1 Handpiece Implant Driver TG 1 FRIADENT® Ratchet FRIADENT® Ratchet Insert for Implant Driver Handpiece Hex Driver 0.0/L 8–18 Round Drill Twist Drill posterior D Twist Drill posterior D Twist Drill posterior D Twist Drill posterior D Twist Drill posterior D Twist Drill anterior D Twist Drill anterior D Twist Drill anterior D Twist Drill anterior D Twist Drill anterior D Twist Drill crestal D Twist Drill crestal D Twist Drill crestal D Twist Drill crestal D Twist Drill crestal D XiVE® Tap Set Drill Extension 3.9 mm/short Ratchet Hex Driver 0.5/L 5.22 mm/long Handle for Contra-angle Hex Driver Ratchet Hex Driver 0.9 mm/long Ratchet Hex Driver 1.8/L 4.22 mm/short Handpiece Hex Driver 1.5 1 Handpiece Implant Driver posterior for Screw Implants D 3. Article XiVE® Instrument Sets Surgery The XiVE® Instrument Sets Surgery contain the instruments required for implant placement.8 4.0 XiVE® Select Try-in Implant D XiVE® Select Try-in Implant D XiVE® Select Try-in Implant D XiVE® Select Try-in Implant D XiVE® Select Try-in Implant D 3.4/L 3.5 5.4–D 6.22 mm/short Ratchet Hex Driver 1.4 3.0/A 15 FRIADENT® Select Try-in Abutment D 3. 8/L 3.4–D 4.0/L 3.5/L 5.4–D 3.5 11 13 15 ExpertSet 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 StandardSet 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 – – – – – – – – – – – – – – – – – – 1 2.5–D 4.5–D 4.5 11 13 15 18 8 9.4–D 3.5–D 4.0–D 2.5–D 4.5/L 5.Order No.5/L 5.0/L 3.0–D 2.0/L 3.4–D 3.4–D 3.4–D 3.8/L 3.8/L 5.0/L 3.0–D 2.0–D 3.5–D 4.5–D 4.0/L 3.4–D 3.8/L 3.8/L 3.0/L 3.5 11 13 15 18 The XiVE® Depth Stops are mounted and removed from the XiVE® drill manually.4–D 4.5/L 5.8/L 5.4–D 3. .5–D 4.5/L 8 9.5/L 5. The kits are supplied in the XiVE® Security Tray.5 11 13 15 8 9. No additional instruments are necessary.0/L 3.0/L 3.8/L 3.0/L 3.0–D 2.4–D 3.5–D 4.0/L 3.0–D 3. Article XiVE® Security Kits 26 – 1200 26 – 1205 XiVE® Expert Security Kit (posterior/anterior) XiVE® Standard Security Kit (posterior only) Contents: Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop posterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D Depth Stop anterior D XiVE® Security Kit Tray 2.0/L 3.5/L 5.5–D 3.5–D 4.0–D 2.0–D 2.5 11 13 15 18 8 9.8/L 3.5/L 5.0–D 2.8/L 3.8/L 3.5/L 8 9.5 11 13 15 8 9.5–D 3. 26 – 8010 26 – 1390 XiVE® Surgical Tray (empty) XiVE® Security Kit Tray (empty) 31 XiVE® The XiVE® Security Kits contain all depth stops required for using the universal XiVE® Twist Drills.5/L 5.4–D 3.8/L 3. over the cutting end.0–D 2.5/L 5.0–D 2. 4/L 8 – L 15 – Ȝ D 3.5/L 8 – L 15 32 .8/L 8 – L 15 26 – 3055 XiVE® Single-patient Drill Set – Ȝ D 4.0/L 8 – L 15 XiVE® Single-patient Drill Set – Ȝ D 3.0/L 8 – L 15 – Ȝ D 3.0/L 8 – L 15 – Ȝ D 3.5/L 8 – L 15 26 – 3065 XiVE® Single-patient Drill Set – Ȝ D 5. Drills Article XiVE® Single-patient Drills (single articles) 26 – 1015 26 – 1025 26 – 1035 26 – 1045 26 – 1055 26 – 1065 – Ț D 2.5/L 8 – L 15 Article sets The XiVE® Single-patient Drill Sets include all twist drills required for implant site preparation of the appropriate implant diameter.4/L 8 – L 15 26 – 3035 26 – 3045 XiVE® Single-patient Drill Set – Ȝ D 3. Once this diameter has been reached.8/L 8 – L 15 – Ȝ D 4. the XiVE® Twist Drill crestal has to be used additionally.Instruments for Implant Placement Order No. 26 – 3025 XiVE® Single-patient Drill Set – Ȝ D 3.5/L 8 – L 15 – Ȝ D 5. 8/L 8–15 ● D 4.5/L 8–18 The XiVE® Twist Drills posterior and anterior are provided with marking grooves for clear distinction: XiVE® Twist Drill crestal6 26 26 26 26 26 – – – – – 1120 1130 1140 1150 1160 – – – – – Ȝ D 3.0/L 8–15 XiVE® Twist Drill anterior6 D 2. The drills are adjusted to the desired implant length by using the respective XiVE® Depth Stops. 33 XiVE® All XiVE® Twist Drills are available in one length. pre-tapping of the implant threads is required in the crestal area after crestal preparation. 26 – 1115 26 – 1118 26 – 1110 XiVE® Twist Drill posterior6 D 2.4/L 8–15 Ȝ D 3.5/L 8–15 XiVE® Twist Drill anterior6 26 26 26 26 26 – – – – – 1128 1138 1148 1158 1168 – – – – – Ȝ D 3.0/L 8–18 Ȝ D 3.8 ● D 4. . In type I bone.5 posterior: 1 groove anterior: 2 grooves Once the appropriate diameter has been reached. The XiVE® Expert Security Kit contains one complete set of depth stops for the XiVE® posterior and anterior Twist Drills.5/L 8–18 Ȝ D 5.0/L 8–15 Ȝ D 3. the XiVE® Tap (see page 35) has to be used. Please replace the cutting instruments after approximately 20 uses or if they are damaged or dull. The XiVE® Standard Security Kit includes only the depth stops for the posterior Twist Drills (see page 31). Article All XiVE® Drills are provided with internal irrigation.5/L 8–15 Ȝ D 5.4/L 8–18 Ȝ D 3. The Twist Drill crestal always has to be used.0 Ȝ D 3.5 Ȝ D 5.Order No.0/L 8–18 XiVE® Round Drill6 XiVE® Twist Drill posterior6 26 26 26 26 26 – – – – – 1125 1135 1145 1155 1165 – – – – – Ȝ D 3.8/L 8–18 ● D 4. Therefore.4 Ȝ D 3. the crestal preparation leads to an internal condensation of the implant site and thus increases primary stability. 5/L 5.0 2.4 3.5/L 5.4 3.8/L 3.0/L 3.5/L 5.4 4.5/L 8 9.0 3.5 4.8/L 3.0/L 3.0 2. The XiVE® Depth Stops are mounted and removed from the XiVE® Drill manually.5/L 5.0/L 3.0 2.8/L 3.5 4.5/L 5.8/L 3.4 3.4 3.5 4.0/L 3.0/L 3.0 2.0/L 3.Instruments for implant placement Order No.0/L 3.8/L 3.5 11 13 15 8 9.5 – – – – – – – – – – – – – – – 3.0 2.0 2.4 3.5/L 8 9.4 3.0/L 3.5 11 13 15 18 posterior: 1 groove anterior: 2 grooves The XiVE® Depth Stops posterior and anterior are also provided with marking grooves for clear distinction.8/L 3. Article Drill Depth Stops XiVE® Depth Stop posterior6 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 – – – – – – – – – – – – – – – 1210 1211 1212 1213 1215 1230 1231 1232 1233 1235 1250 1251 1252 1253 1255 – – – – – – – – – – – – – – – ȚȜD ȚȜD ȚȜD ȚȜD ȚȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD 2.8/L 5.4 3.0 2.0/L 3. over the cutting end.5 4.4 4.5 11 13 15 XiVE® Depth Stop anterior6 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 – – – – – – – – – – – – – – – – – – 1310 1311 1312 1313 1315 1318 1330 1331 1332 1333 1335 1338 1350 1351 1352 1353 1355 1358 – – – – – – – – – – – – – – – – – – ȚȜD ȚȜD ȚȜD ȚȜD ȚȜD ȚȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD ȜȜD 2.5 11 13 15 18 8 9.5 4.0/L 3.5 11 13 15 8 9.5 – – – – – – – – – – – – – – – – – – 3.5 4.0 2.4 3.0 2.8/L 3.8/L 3.4 3.8/L 5.5/L 5. No additional instruments are necessary.5 11 13 15 18 8 9.5 4.5 4.0 3.5/L 5.5/L 5.5/L 5.0/L 3.5 4.8/L 3. 34 . 8 ● D 4.5 The XiVE® Taps are used with the FRIADENT® Ratchet or Handpiece Implant Driver D 3.0 Ȝ D 3.5 XiVE® Tap4 26 26 26 26 26 – – – – – 1121 1131 1141 1151 1161 – – – – – Ȝ D 3.Order No. The XiVE® Tap can be used to reduce the crestal torque achieved during insertion of implants. 26 – 1180 XiVE® Tap Set4 one tap per diameter D 3. 45 – 5280 91 – 0003 90 – 5042 90 – 5043 Article FRIADENT® Drill Cleaning Instrument6 FRIADENT® Drill Extension6 Long Internal Irrigation Tube (for Drill Extension) The drill extension must always be used with the long internal irrigation tube. Taps In very cortical bone. 35 XiVE® FRIOS® Contra-angle Handpiece 20:1 Irrigation Tube XiVE  .4/TempBase.4 Ȝ D 3. pre-tapping of the implant site is required in the crestal area after the initial 6 mm deep preparation.0 – D 5.5 Ȝ D 5. 26 – 1600 Ȝ Ȝ Ȝ Ȝ Ȝ XiVE® Instrument Set BoneCondenser straight and angled (tray with all XiVE® BoneCondensers.0 Ȝ D 3. angled) 26 – 1603 26 – 1606 XiVE® BoneCondenser.0 Ȝ D 3.5 Ȝ D 5. The improved bone quality and quantity increases implant primary stability. without insert FRIADENT® Ratchet Insert for Implant Driver6 36 .Instruments for implant placement Order No. straight) Ȝ Ȝ Ȝ Ȝ Ȝ XiVE® Instrument Set BoneCondenser angled (tray with all XiVE® BoneCondensers.0 Ȝ D 3.8 ● D 4.4 Ȝ D 3. 26 – 1790 XiVE® BoneCondenser Tray5/6/26 (empty) Other Instruments 26 – 1510 45 – 5709 45 – 5711 XiVE® Depth Gauge2 D 2. straight25/6 26 26 26 26 26 26 – – – – – – 1610 1620 1630 1640 1650 1660 – – – – – – Ț D 2. angled25/6 26 26 26 26 26 26 – – – – – – 1615 1625 1635 1645 1655 1665 – – – – – – Ț D 2.8 ● D 4. Depth marks at the working tip indicate the preparation depth.5 XiVE® BoneCondenser.5 The angled XiVE® BoneCondenser are used when limited space is available and for the posterior region.0 FRIADENT® Ratchet6. All XiVE® BoneCondenser are available in one length.0 Ȝ D 3.5 Ȝ D 5. Article XiVE® BoneCondenser XiVE® BoneCondenser can be used in reduced bone quality to condense the lateral and apical bone of the implant site. straight and angled) Ȝ Ȝ Ȝ Ȝ Ȝ XiVE® Instrument Set BoneCondenser straight (tray with all XiVE® BoneCondensers.4 Ȝ D 3. 22 mm/short – width 1.8 – D 6.5 – Ȝ anterior for implants D 3.0 mm/short – blade width 2.Order No. FRIADENT® Handpiece Implant Driver4 – Ȝ posterior for implants D 3.0 46 – 5922 – Ȝ anterior for implants D 3.22 mm/24 Ncm/short – width 1.8 – D 6.0/L 8–18 Ȝ D 3.0 mm/14 Ncm/long FRIADENT® Handpiece Hex Driver6 – width 0.9 mm/14 Ncm/short – width 0.4 and TempBase – Ȝ Ȝ Ȝ Ȝ posterior for implants D 3.5/L 8–18 46 46 46 46 46 46 – – – – – – 5830 5932 5834 5840 5942 5844 45 45 45 45 – – – – 5732 5733 5734 5736 45 – 5714 45 – 5722 46 46 46 46 – – – – 5710 5720 5711 5721 46 – 5712 46 – 5722 46 – 5880 37 XiVE® FRIADENT® Ratchet Implant Driver2 46 – 5810 – Ȝ posterior for implants D 3.8/L 8–18 ● D 4.4 and TempBase 46 – 5820 – Ȝ anterior for implants D 3.0 – Ȝ anterior for implants D 3.9 mm/14 Ncm/long – width 1.9 mm/short – width 0.22 mm/24 Ncm/long FRIADENT® Ratchet Slot Screwdriver6 with torque limit – blade width 2.0 – Ȝ posterior for implants D 3.0 mm/14 Ncm/short – blade width 2.5 FRIADENT® Ratchet Hex Driver6 with torque limit – width 0. Article Please use the FRIALIT® Implant Drivers 46 – 5512 and 46 – 5516 (see page 18) when inserting XiVE® S Screw Implants D 3.8 – D 5.5/L 8–18 Ȝ D 5.4 and TempBase .5 without TempBase.9 mm/long – width 1.22 mm/long FRIADENT® Handpiece Slot Driver6 – blade width 2.0 46 – 5912 – Ȝ posterior for implants D 3.0 mm/long FRIADENT Implant Driver Manual Long XiVE® Trephine Drill 26 26 26 26 26 – – – – – 1129 1139 1149 1159 1169 – – – – – Ȝ D 3.4/L 8–18 Ȝ D 3.4 and TempBase – Ȝ Ȝ Ȝ Ȝ anterior for implants D 3. J Prosthet Dent 1997. 199 873 Möllersten et al. Internal Hex US Patent 5. DENTSPLY Friadent provides the unique concept of platform technology: Identical implant-abutment connection Surgical versatility with unlimited prosthetic flexibility is provided through the universal internal hex connection. A patented connection that has been proven over more than10 years of clinical use for all prosthetic concepts. Therefore. Horizontal or Transverse Screw optional 38 .FRIADENT Prosthetics ® FRIADENT® Prosthetics for FRIALIT® and XiVE® S – Universal compatibility The FRIALIT® and XiVE® implant options cover all indications. the prosthetic procedure should be as simple as possible. From the top of the implant.. 960 381. Comparison of strength and failure mode of seven implant systems: An in vitro test. 78:582-91 FRIALIT® Implants XiVE® S Implants FRIADENT® Cover Screw FRIADENT® Gingiva Former FRIADENT® Transfer Coping with TransferCap FRIADENT® ProTect FRIADENT® EsthetiCap FRIADENT® EstheticBase straight and angled. 2 1 1 2 Patent EP 0438 048 and US 4. 0 FRIALIT ® ® D 3.5 Ȝ Ȝ D 5.8 Ȝ Ȝ D 4.Implant diameters/prosthetic diameters D 3.5 Ȝ Ȝ D 6.5 Ȝ XiVE S Ȝ FRIADENT® MP Cover Screw FRIADENT® MP Transfer or PickUp Impression Coping XiVE® TG implants: implant-abutmentconnection compatible with FRIADENT® MP Abutment FRIADENT® CERCON® Abutment FRIADENT® CeraBase FRIADENT® AuroBase FRIADENT® Telescopic Abutment FRIADENT® Ball and Socket Attachment FRIADENT® MP Abutment with Bar Coping or Waxing Sleeve 39 FRIADENT® Prosthetics for FRIALIT® & XiVE® S .4 Ȝ Ȝ D 3. 40 . FRIADENT® Prosthetics At uncovery. you will decide whether to fabricate the superstructure ■ from the implant level or ■ from the gingival level (MP Abutment). based on the indication. Impression Making Single Crowns Bridges Overdentures at implant level pages 43 – 54 FRIADENT® EstheticBase straight or angled FRIADENT® Transfer Coping (Transfer Technique) FRIADENT® EstheticBase straight or angled Telescopic Abutment FRIADENT® Transfer Coping (PickUp Technique) Telescopic Abutment FRIADENT® FRIADENT® CERCON® CeraBase Ceramic Abutments at gingival level (MP Abutment) FRIADENT® MP Impression Coping (Transfer technique) FRIADENT® MP Abutment (Bridge) with Castable or Cast-to Waxing Sleeve pages 55 – 61 FRIADENT® MP Abutment (Bar) with Gold. Titanium or Castable Bar Coping FRIADENT® MP Impression Coping (PickUp Technique) FRIADENT® MP Abutment 41 FRIADENT® Prosthetics for FRIALIT® & XiVE® S FRIADENT® AuroBase FRIADENT® Attachment . 0 Ȝ D 3. The geometry of the FRIALIT® BoneProfiler exactly matches that of the Gingiva Former.5 45 – 5300 45 – 5550 FRIADENT® Guide Pin for BoneProfiler FRIADENT® Soft Tissue Gauge6 42 .5 Ȝ D 6.8 ● D 4.5 6. With the FRIALIT® BoneProfiler.4 3.5 Ȝ D 5. Article Soft Tissue Punches FRIADENT® Tissue Punch6 45 45 45 45 45 45 – – – – – – 5665 5666 5660 5661 5662 5663 – – – – – – Ȝ D 3.5 5.5 BoneProfiler In case of implants placed subcrestally. this bone can be removed and the Cover Screw uncovered.4 Ȝ D 3.8 4. new bone can grow over the implant during the healing phase. FRIADENT® BoneProfiler6 45 45 45 45 45 – – – – – 5338 5348 5358 5368 5378 – – – – – ȜD ȜD ●D ȜD ȜD 3.Uncovery Order No. FRIALIT® implants Ȝ D 6.5 abutments.0 components (bronze) can only be used for XiVE®. Please note: Ȝ D 3.0/GH 3.5/GH 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 1 mm GH 1 2 mm 3 mm GH 3 5 mm ȜD ȜD ȜD ȜD GH 5 The gingiva formers are threaded in with the 0.4/GH 3.5/GH 5.4/GH 3.5/GH 5.4/GH 3.8/GH 3.8/GH 3. 43 FRIADENT® Prosthetics for FRIALIT® & XiVE® S GH 2 .9 mm FRIADENT Hex Driver or with the blade width 2.5/GH 4.0 mm FRIADENT® Slot Screwdriver (see page 64).5/GH 5. Article Gingiva Formers FRIADENT® Gingiva Former2 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 – – – – – – – – – – – – – – – – – – – – 1421 1422 1423 1425 1431 1432 1433 1435 1441 1442 1443 1445 1451 1452 1453 1455 1461 1462 1463 1465 – – – – – – – – – – – – – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ● ● ● ● D D D D 3.0/GH 3.8/GH 4.8/GH 3.5/GH 5.Prosthetic fabrication at implant level: Soft tissue management.0/GH 3.0/GH 3.4/GH 3.5 (green) are restored with Ȝ D 5. provisional restorations Order No.5/GH 4.5/GH 4. thus enabling simple and safe soft tissue surgery.5/GH 5 The FRIADENT® Gingiva Former Loop allows easy securing of suture material.8/GH 3 – Ȝ D 3.5/GH 2 – ● D 4.8/GH 5 – ● D 4.5/GH 3 – Ȝ D 5. FRIADENT® Gingiva Former2 Loop 45 – 1333 45 – 1335 45 – 1343 45 – 1345 45 – 1353 45 – 1355 45 – 1363 45 – 1365 – Ȝ D 3. 44 . provisional restorations Order No. the FRIADENT ® Transfer Coping Slim (see page 47) is used.8/GH 2 – Ȝ D 3.8/GH 5 – ● D 4.8/GH 3 – Ȝ D 3.5/GH 3 – ● D 4.5/GH 3 – ● D 4. Article FRIADENT® Gingiva Former2 Slim 45 – 1232 45 – 1233 45 – 1235 45 – 1242 45 – 1243 45 – 1245 45 – 1252 45 – 1253 45 – 1255 – Ȝ D 3.4/GH 5 – Ȝ D 3.4/GH 3 – Ȝ D 3.5/GH 5 – Ȝ D 5.5/GH 5 With the FRIADENT ® Gingiva Former Slim a perfect contouring of the soft tissue can be achieved in cases with limited mesio-distal space. For making impressions.4/GH 2 – Ȝ D 3.4/GH 3 – Ȝ D 3.Prosthetic fabrication at implant level: Soft tissue management.4/GH 5 – Ȝ D 3. 4/oval – Ȝ D 3.5/oval – ● D 4. 45 FRIADENT® Prosthetics for FRIALIT® & XiVE® S Provisional Restorations .Order No. FRIALIT® implants Ȝ D 6.0 components (bronze) can only be used for XiVE®.8 4.5 5. the FRIADENT® EsthetiCap abutments provide perfect anatomical and esthetic peri-implant gingival contours by simple customization. Article FRIADENT® EsthetiCap with Screw for EsthetiCap 46 – 1730 46 – 1740 46 – 1745 46 – 1750 46 – 1755 46 – 1760 46 – 1765 – Ȝ D 3.5 (green) are restored with Ȝ D 5.8/triangular – ● D 4.8/oval – Ȝ D 3.5 The PickUp Guide Pin ensures optimum stability for the provisional abutment.5 abutments.4 3. FRIADENT® ProTect Abutment24 with PickUp Guide Pin4 45 45 45 45 – – – – 1530 1540 1550 1560 – – – – ȜD ȜD ●D ȜD 3.5/triangular As anatomical gingiva formers.5/oval – Ȝ D 5. Please note: Ȝ D 3.5/triangular – Ȝ D 5. 5/GH 5 FRIADENT® Lab Set PickUp Impression The Lab Set PickUp Impression contains Transfer Coping.0) and Implant Analog 46 – 8123 46 – 8125 46 – 8133 46 – 8135 46 – 8143 46 – 8145 46 – 8153 46 – 8155 46 – 8163 46 – 8165 – Ȝ D 3.5/GH 5 The Transfer Coping GH 3 is used for gingiva up to 3 mm thick.0/GH 3 – Ȝ D 3.0 – D 5.8/GH 3 – Ȝ D 3.4/GH 5 – Ȝ D 3. FRIADENT® TransferCap (D 3.4/GH 5 – Ȝ D 3.5/GH 3 – ● D 4.4/GH 3 – Ȝ D 3.5).8/GH 5 – ● D 4.0 with Abutment Screw D 3.8/GH 5 – ● D 4. Article FRIADENT® Lab Set Transfer Impression The Lab Set Transfer Impression contains Transfer Coping.5/GH 5 – Ȝ D 5.0) and Implant Analog 46 – 8223 46 – 8225 46 – 8233 46 – 8235 46 – 8243 46 – 8245 46 – 8253 46 – 8255 46 – 8263 46 – 8265 – Ȝ D 3.4/GH 3 – Ȝ D 3. Standard Abutment Screw (D 3.0 – D 5.5/GH 3 – Ȝ D 5.0/GH 5 – Ȝ D 3. Please use the Transfer Coping GH 5 for gingiva exceeding 3 mm thickness.5/GH 3 – ● D 4.0/GH 3 – Ȝ D 3.Prosthetic fabrication at implant level: Impressions Order No.8/GH 3 – Ȝ D 3.5/GH 3 – Ȝ D 5.0 with Abutment Screw D 3. FRIADENT® TransferCap (D 3.5). GH 3 3 mm GH 5 5 mm 46 .5/GH 5 – Ȝ D 5.0/GH 5 – Ȝ D 3. Standard Abutment Screw (D 3. Order No. Article FRIADENT® Transfer Coping (Transfer Technique) with Standard Abutment Screw4 (D 3.0 with Abutment Screw4 D 3.0) and TransferCap20 (D 3.0 – D 5.5) 45 – 1620 45 – 1621 45 – 1630 45 – 1631 45 – 1640 45 – 1641 45 – 1650 45 – 1651 45 – 1660 45 – 1661 – Ȝ D 3.0/GH 3 4 – Ȝ D 3.0/GH 5 4 – Ȝ D 3.4/GH 3 4 – Ȝ D 3.4/GH 5 4 – Ȝ D 3.8/GH 3 2 – Ȝ D 3.8/GH 5 2 – ● D 4.5/GH 3 2 – ● D 4.5/GH 5 2 – Ȝ D 5.5/GH 3 2 – Ȝ D 5.5/GH 5 2 FRIADENT® Transfer Coping (PickUp Technique) with PickUp Guide Pin4 (D 3.0 with PickUp Guide Pin4 D 3.0) and TransferCap20 (D 3.0 – D 5.5) 45 – 1625 45 – 1622 45 – 1635 45 – 1632 45 – 1645 45 – 1642 45 – 1655 45 – 1652 45 – 1665 45 – 1662 – Ȝ D 3.0/GH 3 4 – Ȝ D 3.0/GH 5 4 – Ȝ D 3.4/GH 3 4 – Ȝ D 3.4/GH 5 4 – Ȝ D 3.8/GH 3 2 – Ȝ D 3.8/GH 5 2 – ● D 4.5/GH 3 2 – ● D 4.5/GH 5 2 – Ȝ D 5.5/GH 3 2 – Ȝ D 5.5/GH 5 2 FRIADENT® Transfer Coping Slim2 45 – 1239 45 – 1249 45 – 1259 – Ȝ D 3.4 – Ȝ D 3.8 – ● D 4.5 The FRIADENT® Transfer Coping Slim is used if – in cases with limited mesiodistal space – the contouring of the soft tissue has been made with the Gingiva Former Slim (see page 44). 47 FRIADENT® Prosthetics for FRIALIT® & XiVE® S Prosthetic fabrication at implant level: Impressions Order No. Article FRIADENT® Transfer Coping Basic2 46 46 46 46 – – – – 1632 1642 1652 1662 – – – – Ȝ D 3.4 Ȝ D 3.8 ● D 4.5 Ȝ D 5.5 The FRIADENT® Transfer Coping Basic is used for simple impression making in cases with implant divergencies. 46 – 4304 45 – 4305 46 – 1605 45 – 1615 Ȝ FRIADENT® Standard Abutment Screw 4 D 3.0 Ȝ Ȝ Ȝ Ȝ FRIADENT® Standard Abutment Screw4 Ȝ FRIADENT® PickUp Guide Pin4 D 3.0 Ȝ Ȝ Ȝ Ȝ FRIADENT® PickUp Guide Pin4 Abutment screws and guide pins are seated with the 0.9 mm FRIADENT® Hex Driver or with the blade width 2.0 mm FRIADENT® Slot Screwdriver (see page 70). TransferCaps FRIADENT® TransferCaps allow for greater precision during impression so that the implant inner geometry is transferred with even greater accuracy. The result is the best possible superstructure fit. FRIADENT® TransferCaps are not available for diameter D 6.5. FRIADENT® Multi-Pack TransferCap20 (3 pieces) 45 45 45 45 45 – – – – – 1629 1639 1649 1659 1669 – – – – – Ȝ D 3.0 Ȝ D 3.4 Ȝ D 3.8 ● D 4.5 Ȝ D 5.5 Please note: Ȝ D 3.0 components (bronze) can only be used for XiVE®. FRIALIT® implants Ȝ D 6.5 (green) are restored with Ȝ D 5.5 abutments. 48 Prosthetic fabrication from the implant level: Prosthetics/laboratory Order No. Article FRIADENT® Implant Analog5 45 45 45 45 45 45 – – – – – – 4020 4030 4040 4050 4060 4070 – – – – – – Ȝ D 3.0 Ȝ D 3.4 Ȝ D 3.8 ● D 4.5 Ȝ D 5.5 Ȝ D 6.5 Try-in Abutments Gingival height, angle and the correct position of the horizontal screw (GH 2) for FRIADENT® abutments can easily and quickly be determined with the FRIADENT® Select Try-in Abutments. FRIADENT® Select Try-in Abutment2 45 45 45 45 45 45 45 45 – – – – – – – – 2119 2120 2121 2122 2123 2219 2220 2221 – – – – – – – – 3.0/A 3.4/A 3.8/A 4.5/A 5.5/A 3.0/A 3.4/A 3.8/A 0 (straight) 0 (straight) 0 (straight) 0 (straight) 0 (straight) 15 (angled 15°) 15 (angled 15°) 15 (angled 15°) FRIADENT® Select Try-in Abutment Multi-Pack2 (3 pieces) 45 45 45 45 45 45 – – – – – – 2193 2194 2195 2196 2293 2294 – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD 3.4/A 3.8/A 4.5/A 5.5/A 3.4/A 3.8/A 0 (straight, 3 pieces) 0 (straight, 3 pieces) 0 (straight, 3 pieces) 0 (straight, 3 pieces) 15 (angled, 3 pieces) 15 (angled, 3 pieces) 49 FRIADENT® Prosthetics ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD for FRIALIT® & XiVE® S Prosthetic fabrication at implant level: Prosthetics/laboratory Abutments for single tooth restorations and bridges Order No. Article EstheticBase Abutments FRIADENT® EstheticBase straight / A 0 Screw for EstheticBase4 (D 3.0 with Abutment Screw4 D 3.0) 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 – – – – – – – – – – – – – – – – – – – – 2121 2122 2123 2125 2131 2132 2133 2135 2141 2142 2143 2145 2151 2152 2153 2155 2161 2162 2163 2165 – – – – – – – – – – – – – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ● ● ● ● D D D D 3.0/GH 3.0/GH 3.0/GH 3.0/GH 3.4/GH 3.4/GH 3.4/GH 3.4/GH 3.8/GH 3.8/GH 3.8/GH 3.8/GH 4.5/GH 4,5/GH 4.5/GH 4.5/GH 5.5/GH 5.5/GH 5.5/GH 5.5/GH 14 24 34 54 14 24 34 54 12 22 32 52 12 22 32 52 12 22 32 52 GH 1 GH 2 GH 3 GH 5 1 mm 2 mm 3 mm 5 mm All FRIADENT® EstheticBase Abutments are provided with a horizontal thread (M 1.4). An additional horizontal or transverse screw set is necessary for horizontally screw-retained crowns (see page 52). ȜD ȜD ȜD ȜD We recommend the use of special titanium drills (Gebr. Brasseler, Lemgo or Jota Düsseldorf) for preparing the abutments. Abutment screws 46 – 4304 46 – 4305 Ȝ FRIADENT® Standard Abutment Screw4 D 3,0 Ȝ Ȝ Ȝ Ȝ FRIADENT® Screw4 for EstheticBase Please note: Ȝ D 3.0 components (bronze) can only be used for XiVE®. FRIALIT® implants Ȝ D 6.5 (green) are restored with Ȝ D 5.5 abutments. 50 Order No.5/GH 5.8/GH 4.5/GH 5. 51 FRIADENT® Prosthetics for FRIALIT® & XiVE® S .8/GH 3.0/GH 3.0/GH 3. the use of the Horizontal Screw Set with a long head is recommended.8/GH 3.5/GH 4.9 mm FRIADENT® Hex Driver (see page 64). as the crown usually requires broader buccal-lingual width. Particularly for molars.5/GH 14 24 34 54 14 24 34 54 12 22 32 52 12 22 32 52 12 22 32 52 ȜD ȜD ȜD ȜD Horizontal screws 46 – 4403 46 – 4404 46 – 4407 46 – 4408 46 – 4401 46 – 4402 46 – 4405 46 – 4406 45 – 4410 FRIADENT® Horizontal Screw Set Standard with Horizontal Screw Standard4 and Horizontal Screw Seat8 FRIADENT® Horizontal Screw Set Long with Horizontal Screw Long4 and Horizontal Screw Seat8 FRIADENT® Transverse Screw Set Standard with Transversal Screw Standard4 and Horizontal Screw Seat8 FRIADENT® Transverse Screw Set Long with Transversal Screw Long4 and Horizontal Screw Seat8 FRIADENT® Horizontal Screw Standard4 FRIADENT® Horizontal Screw Long4 FRIADENT® Transverse Screw Standard4 FRIADENT® Transverse Screw Long4 FRIADENT® Horizontal Screw Seat8 Horizontal screws are seated in with the 0.0) 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 – – – – – – – – – – – – – – – – – – – – 2221 2222 2223 2225 2231 2232 2233 2235 2241 2242 2243 2245 2251 2252 2253 2255 2261 2262 2263 2265 – – – – – – – – – – – – – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ● ● ● ● D D D D 3.4/GH 3.0/GH 3.4/GH 3.8/GH 3.5/GH 5.5/GH 4.4/GH 3.4/GH 3.5/GH 4.0 with Abutment Screw4 D 3. Article FRIADENT® EstheticBase angled / A 15 Screw for EstheticBase4 (D 3.0/GH 3.5/GH 5. 45 – 2530 45 – 2531 45 – 2540 45 – 2541 45 – 2550 45 – 2551 45 – 2560 45 – 2561 – Ȝ D 3. neutral – Ȝ D 3. FRIADENT® CeraBase Abutment with Standard Abutment Screw4.4 conical 30/4 – Ȝ D 3. dentin – ● D 4. The grinding process of the CERCON® Abutments requires irrigation.5 anatomical30/3 We recommend using the FRIADENT® CeraBase Tool Set for prepping the ceramic sleeve of the FRIADENT® CeraBase Abutment (see page 65). neutral – Ȝ D 3. dentin FRIADENT® CERCON® Abutment32 angled / A 15 with Screw 47 – 1241 47 – 2241 47 – 1251 47 – 2251 47 – 1242 47 – 2242 47 – 1252 47 – 2252 – Ȝ D 3. neutral – Ȝ D 3.8/GH2.5/GH2. dentin – ● D 4.8/GH1.8/GH2. neutral – ● D 4.8 anatomical30/3 – ● D 4.8/GH1. Article Ceramic Abutments FRIADENT® CERCON® Abutment32 straight / A 0 with Screw 47 – 1141 47 – 2141 47 – 1151 47 – 2151 47 – 1142 47 – 2142 47 – 1152 47 – 2152 – Ȝ D 3. Please note that the indication is restricted to the front tooth region. neutral – Ȝ D 3. dentin We recommend using the ceramic-line Shaping Set of DeguDent for prepping the FRIADENT ® CERCON® Abutments.5/GH1.5/GH1. dentin – Ȝ D 3.8 conical 30/3 – Ȝ D 3.8/GH1. dentin – Ȝ D 3. The grinding process does not require irrigation. dentin – ● D 4. neutral – ● D 4.4 anatomical30/4 – Ȝ D 3.8/GH2. 52 .5 anatomical30/3 – Ȝ D 5.5/GH2.5/GH1.5/GH2.8/GH2.5 conical 30/3 – ● D 4. neutral – ● D 4. neutral – ● D 4. dentin – ● D 4.5/GH1.Prosthetic fabrication at implant level: Prosthetics/laboratory Abutments for single tooth restorations and bridges Order No.5/GH2.8/GH1.5 conical 30/3 – Ȝ D 5. Duceratin. Vita Zahnfabrik) for occlusally screw-retained single crowns.0 Ȝ D 3.0 with Abutment Screw4 D 3.0 Ȝ D 3.0) 45 45 45 45 45 – – – – – 2420 2430 2440 2450 2460 – – – – – Ȝ D 3. Article Cast-to Abutments FRIADENT® AuroBase20/8 Abutment with Standard Abutment Screw4 (D 3.g.8 ● D 4.0 with Abutment Screw4 D 3..5 Telescopic Abutments FRIADENT® Telescopic Abutment with Standard Abutment Screw4 (D 3.4 Ȝ D 3.5 2 The Telescopic Abutment can also be used as a custom abutment for single crowns.5 53 FRIADENT® Prosthetics for FRIALIT® & XiVE® S . The Telescopic Abutment can be veneered with titanium ceramics (e. Abutment screws 46 – 4304 46 – 4305 Ȝ FRIADENT® Standard Abutment Screw4 D 3.0 4 Ȝ D 3.0 Ȝ Ȝ Ȝ Ȝ FRIADENT® Screw4 for EstheticBase Milling Implants FRIADENT® Milling Implant6 45 45 45 45 45 – – – – – 2621 2631 2641 2651 2661 – – – – – Ȝ D 3.5 2 Ȝ D 5.5 Ȝ D 5.Order No.4 4 Ȝ D 3.0) 45 45 45 45 45 – – – – – 2620 2630 2640 2650 2660 – – – – – Ȝ D 3.8 2 ● D 4.8 ● D 4.4 Ȝ D 3.5 Ȝ D 5. Ducera or Vita Titankeramik. 5/GH 5.5/GH 5.8/GH 4.8/GH 3. 45 – 3200 45 – 4105 Ȝ Ȝ Ȝ Ȝ FRIADENT® Attachment Matrix9 Ȝ Ȝ Ȝ Ȝ FRIADENT® Attachment Patrix Analog universal The FRIADENT® Attachment Patrix Analog is used to repair and reline overdentures. with blue silicone ring and white plastic ring 45 – 3131 45 – 3132 45 – 3133 45 45 45 45 45 45 45 45 45 45 45 45 – – – – – – – – – – – – 3141 3142 3143 3145 3151 3152 3153 3155 3161 3162 3163 3165 – Ȝ D 3. Socket9 (gold alloy). The Attachment Screw is seated in the implant using the 1.8/GH 3. The Analog is snapped into the socket in the denture base after reline impressions are made. Article FRIADENT® Ball and Socket Attachment Insert2.Prosthetic fabrication at implant level: Prosthetics/laboratory Attachments Order No. Attachment Screw2.5/GH 5.5/GH 5.4/GH 1 4 – Ȝ D 3.8/GH 3.5/GH 4. One Patrix Analog is used for all diameters.5/GH 12 22 32 52 12 22 32 52 12 22 32 52 ȜD ȜD ȜD ȜD The gingival collar section of the FRIADENT® Ball and Socket Attachment is positioned using the FRIADENT® Seating Instrument for Attachment Insert and MP Insert. 54 .5/GH 4.5/GH 4.4/GH 2 4 – Ȝ D 3.22 mm FRIADENT® Hex Driver (see page 70).4/GH 3 4 – – – – – – – – – – – – ȜD ȜD ȜD ȜD ● ● ● ● D D D D 3. The number of the grooves on the screw head indicates the gingival height of the matching MP Abutment Insert.5/GH 4.Prosthetic fabrication at gingival level (MP Abutment): Transgingival extension.8/GH 3.4/GH 3.8/GH 4.5/GH 4.8/GH 3.5/GH 5.5/GH 1 2 3 5 1 2 3 5 9 1 2 3 5 9 1 2 3 5 ȜD ȜD ȜD ȜD The appropriate MP Abutment Insert is selected according to the gingival height. 55 FRIADENT® Prosthetics for FRIALIT® & XiVE® S . GH 1 = 1 ring GH 2 = 2 rings GH 3 = 3 rings GH 5 = 5 rings The MP Abutment Inserts are mounted on the implants with the Seating Instrument for Attachment Insert and MP Insert. Article FRIADENT® MP Abutment2 MP Abutment Insert and MP Insert Screw 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 – – – – – – – – – – – – – – – – – – 2831 2832 2833 2835 2841 2842 2843 2845 2849 2851 2852 2853 2855 2859 2861 2862 2863 2865 – – – – – – – – – – – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ● ● ● ● ● D D D D D 3.5/GH 4.5/GH 5.5/GH 4. temporary sealing Order No.4/GH 3.8/GH 3.5/GH 5.4/GH 3.4/GH 3. The MP Abutment Screw is tightened with the MP Abutment Screw Driver for ratchet or handpiece (see page 65).8/GH 3.5/GH 5. 8 ● D 4. 56 . Article FRIADENT® MP Cover Screw2 46 46 46 46 – – – – 1430 1440 1450 1460 – – – – Ȝ D 3.0 components (bronze) can only be used for XiVE®.5 (green) are restored with Ȝ D 5. temporary sealing Order No.5 abutments.5 Ȝ D 5.5 Please note: Ȝ D 3.Prosthetic fabrication at gingival level (MP Abutment): Transgingival extension.4 Ȝ D 3. FRIALIT® implants Ȝ D 6. Article FRIADENT® MP Lab Set Transfer Impression Content: MP Transfer Impression Coping.4 Ȝ D 3.5 Ȝ D 5.8 ● D 4.5 FRIADENT® MP Lab Set PickUp Impression Content: MP PickUp Impression Coping. MP Analog 46 46 46 46 – – – – 8130 8140 8150 8160 – – – – Ȝ D 3.5 Ȝ D 5.8 ● D 4. FRIADENT® MP Analog5 46 46 46 46 – – – – 4030 4040 4050 4060 – – – – Ȝ D 3.8 ● D 4.22 mm FRIADENT® Hex Driver (see page 70).4 Ȝ D 3.5 FRIADENT® MP PickUp Impression Coping2 46 46 46 46 – – – – 1630 1640 1650 1660 – – – – Ȝ D 3. MP PickUp Guide Pin.4 Ȝ D 3.Prosthetic fabrication at gingival level (MP Abutment): Impressions Order No.5 Ȝ D 5.5 57 FRIADENT® Prosthetics for FRIALIT® & XiVE® S .5 Ȝ D 5.8 ● D 4.5 FRIADENT® MP Transfer Impression Coping2 46 46 46 46 – – – – 1635 1645 1655 1665 – – – – Ȝ D 3. MP Analog 46 46 46 46 – – – – 8230 8240 8250 8260 – – – – Ȝ D 3.5 46 – 1615 Ȝ Ȝ ● Ȝ FRIADENT® MP PickUp Guide Pin4 We recommend securing the MP PickUp Guide Pin with the width 1.4 Ȝ D 3.4 Ȝ D 3.8 ● D 4.5 Ȝ D 5. 8 ● D 4.5 FRIADENT® MP Lab Set Bridge with Cast-to Waxing Sleeve Content: Cast-to Waxing Sleeve.5 abutments.5 Ȝ D 5. 58 .5 Ȝ D 5.Prosthetic fabrication at gingival level (MP Abutment): Prosthetics/laboratory Bridges Order No.5 Please note: Ȝ D 3.5 (green) are restored with Ȝ D 5. FRIALIT® implants Ȝ D 6. MP Screw for Waxing Sleeve 46 46 46 46 – – – – 9530 9540 9550 9560 – – – – Ȝ D 3.0 components (bronze) can only be used for XiVE®.4 Ȝ D 3.4 Ȝ D 3.8 ● D 4. MP Screw for Waxing Sleeve 46 46 46 46 – – – – 9930 9940 9950 9960 – – – – Ȝ D 3. Article FRIADENT® MP Lab Set Bridge with Castable Waxing Sleeve Content: Castable Waxing Sleeve. Article Waxing Sleeves FRIADENT® Castable Waxing Sleeve21 45 45 45 45 – – – – 4330 4340 4350 4360 – – – – Ȝ D 3. 46 – 4300 Ȝ Ȝ Ȝ Ȝ FRIADENT® MP Screw for Castable Waxing Sleeve4 We recommend using the 1.4 Ȝ D 3.8 ● D 4.5 Ȝ D 5. smooth the contact surface between crown and abutment and the screw and screw seat using the FRIADENT® Finishers (see page 65). universal and Soldering Screw for Bridge Ȝ Ȝ Ȝ Ȝ FRIADENT® Soldering Analog6. universal Ȝ Ȝ Ȝ Ȝ FRIADENT® Soldering Screw for Bridge4 45 – 4103 45 – 4207 59 FRIADENT® Prosthetics for FRIALIT® & XiVE® S Castable Waxing Sleeve: Prior to bridge delivery.5 Ȝ D 5. .22 mm FRIADENT® Hex Driver (see page 64) when seating the Screw for the Waxing Sleeve. Soldering Analogs 45 – 4102 Ȝ Ȝ Ȝ Ȝ FRIADENT® Lab Set Soldering Analog for Bridge FRIADENT® Soldering Analog.Order No.5 Cast-to Waxing Sleeve: Smoothing with finishers is not necessary.5 FRIADENT® Cast-to Waxing Sleeve21/8 45 45 45 45 – – – – 4630 4640 4650 4660 – – – – Ȝ D 3.4 Ȝ D 3.8 ● D 4. 8 ● D 4. MP Screw for Bar Coping 46 46 46 46 – – – – 9630 9640 9650 9660 – – – – Ȝ D 3.5 FRIADENT® MP Lab Set Castable Bar Coping Content: Castable Bar Coping.4 Ȝ D 3.5 Ȝ D 5. for soldering 45 45 45 45 – – – – 4230 4240 4250 4260 – – – – Ȝ D 3.4 Ȝ D 3.4 Ȝ D 3.4 Ȝ D 3.5 Ȝ D 5.8 ● D 4.4 Ȝ D 3.5 Ȝ D 5.5 Bar Copings FRIADENT® Gold Bar Coping9 (without screw). MP Screw for Bar Coping 46 46 46 46 – – – – 9638 9648 9658 9668 – – – – Ȝ D 3.5 FRIADENT® MP Lab Set Titanium Bar Coping Content: Titanium Bar Coping.Prosthetic fabrication at gingival level (MP Abutment): Prosthetics/laboratory Bars Order No.5 FRIADENT® Titanium Bar Coping2 (without screw) 45 45 45 45 – – – – 4231 4241 4251 4261 – – – – Ȝ D 3.8 ● D 4.5 Ȝ D 5.5 60 .5 Ȝ D 5. MP Screw for Bar Coping 46 46 46 46 – – – – 9637 9647 9657 9667 – – – – Ȝ D 3.8 ● D 4. Article FRIADENT® MP Lab Set Gold Bar Coping Content: Gold Bar Coping9.8 ● D 4. Order No.5 Ȝ D 5. universal Ȝ Ȝ Ȝ Ȝ FRIADENT® Soldering Screw for Bar4 45 – 4103 45 – 4206 61 FRIADENT® Prosthetics for FRIALIT® & XiVE® S 45 – 4210 FRIADENT® Gold Bar round9 50 mm length .5 46 – 4200 FRIADENT® MP Coping Screw4 We recommend using the 1. Accessories 45 – 4215 FRIADENT® Gold Bar Clip9 50 mm length FRIADENT® Titanium Bar round2 50 mm length 45 – 4212 Soldering Analogs 45 – 4101 Ȝ Ȝ Ȝ Ȝ FRIADENT® Lab Set Soldering Analog for Bar FRIADENT® Soldering Analog.22 mm FRIADENT® Hex Driver when seating MP Coping Screw (see page 64). universal and Soldering Screw for Bar Ȝ Ȝ Ȝ Ȝ FRIADENT® Soldering Analog6.8 ● D 4. Article FRIADENT® Castable Bar Coping21 (without screw) 45 45 45 45 – – – – 4530 4540 4550 4560 – – – – Ȝ D 3.4 Ȝ D 3. Content: FRIADENT® Ratchet Ratchet Hex Driver 0.0 mm/long Seating Instrument for Transfer Coping and MH-6 Abutment/A 0 Seating Instrument for Attachment Insert and MP Insert Handpiece Seating Instrument for MP Insert Screw Ratchet Seating Instrument for MP Insert Screw 48 – 0030 FRIALIT® Prosthetic Tray (empty) 62 .9 mm Handpiece Hex Driver 1. Content: FRIADENT® Ratchet Handpiece Hex Driver 0. The instruments are supplied in the FRIALIT® Prosthetic Tray.22 mm/long Ratchet Slot Screwdriver 2.22 mm/short Ratchet Hex Driver 1.Instrument sets impression/prosthetics Order No. Article 46 – 7000 FRIADENT® Prosthetic Set Mini The Prosthetic Set Mini includes all instruments needed for the prosthetic delivery of implant restorations.22 mm/short 45 – 8111 FRIALIT® Basic Set Prosthetics The set includes all clinical instruments necessary for impression making and prosthetics.22 mm Ratchet Hex Driver 0.9 mm/short Ratchet Hex Driver 1.9 mm/short Ratchet Hex Driver 1. 22 mm/short Ratchet Hex Driver 1.4/A 15 FRIADENT® Select Try-in Abutment D 3.0/A 15 FRIADENT® Select Try-in Abutment D 3. The instruments are supplied in the XiVE® Prosthetic Tray.5/A 0 FRIADENT® Select Try-in Abutment D 3.22 mm/short Handpiece Hex Driver 1.4/A 0 FRIADENT® Select Try-in Abutment D 3.9 mm/short Handpiece Hex Driver 0.8/A 15 26 – 8025 XiVE® Prosthetic Tray (empty) 63 FRIADENT® Prosthetics for FRIALIT® & XiVE® S .8/A 0 FRIADENT® Select Try-in Abutment D 4.22 mm/long Seating Instrument for Attachment Insert and MP Insert Handpiece Seating Instrument for MP Insert Screw Ratchet Seating Instrument for MP Insert Screw Insertion Tool EstheticBase FRIADENT® Select Try-in Abutment D 3.9 mm/long Handpiece Hex Driver 1. Article 26 – 8020 XiVE® Prosthetic Tray The set includes all clinical instruments necessary for impression making and prosthetics.0/A 0 FRIADENT® Select Try-in Abutment D 3.22 mm/long Handle for Handpiece Hex Driver Ratchet Hex Driver 0. Content: FRIADENT® Ratchet Handpiece Hex Driver 0.Order No.9 mm/long Ratchet Hex Driver 1.5/A 0 FRIADENT® Select Try-in Abutment D 5.9 mm/short Ratchet Hex Driver 0. 22 mm/short – width 1.0 mm/long FRIADENT® Handle for Handpiece Hex Driver6 45 45 45 45 – – – – 5732 5733 5734 5736 45 – 5714 45 – 5722 46 46 46 46 – – – – 5710 5720 5711 5721 46 – 5712 46 – 5722 46 – 5750 This handle fits all handpiece drivers.0 mm/14 Ncm/short – blade width 2.9 mm/long – width 1. 45 – 5709 Article FRIADENT® Ratchet6.9 mm FRIADENT® Hex Driver without torque limit is recommended for regions with limited access. without inserts FRIADENT® Ratchet Hex Driver6 with torque limit – width 0.9 mm/short – width 0. 64 .22 mm/24 Ncm/long FRIADENT® Ratchet Slot Screwdriver6 with torque limit – blade width 2.0 mm/short – blade width 2.Instruments for impression/ prosthetics/laboratory Order No.22 mm/24 Ncm/short – width 1.9 mm/14 Ncm/long – width 1.22 mm/long FRIADENT® Handpiece Slot Screwdriver6 – blade width 2.9 mm/14 Ncm/short – width 0. FRIADENT® Hex Driver6 without torque limit – width 0.0 mm/14 Ncm/long FRIADENT® Handpiece Hex Driver6 – width 0.9 mm 45 – 5650 The 0. 20 Hermetics Sealing Rings) FRIADENT® Hermetics Seating Instrument2 FRIADENT® CeraBase Tool Set Contents: Medium Diamond Drill. Rubber Polishing Wheel FRIADENT® CeraBase Medium Diamond Drill 45 – 5702 45 – 5600 45 – 5601 45 – 5750 45 – 5753 45 – 5755 45 – 5758 45 – 5617 FRIADENT® CeraBase Rubber Polishing Wheels (5 pieces) FRIADENT® Seating Instrument2 for Attachment Insert and MP Insert FRIADENT® Ratchet Seating Instrument6 for MP Insert Screw FRIADENT® Handpiece Seating Instrument for MP Insert Screw FRIADENT® Activator6 for Ball and Socket Attachment FRIADENT® Deactivator6 for Ball and Socket Attachment FRIADENT® Bar Clip Activator6 FRIADENT® Finisher6/10 for Abutment Seat for screw-retained superstructures – Ȝ Ȝ Ȝ D 3.5 – Ȝ D 5.5 FRIADENT® Finisher6/10 for Screw Head Seat for screw-retained superstructures 46 – 5610 46 – 5615 45 – 5621 45 – 5622 45 – 5623 45 – 5705 45 – 5707 45 – 5700 65 FRIADENT® Prosthetics for FRIALIT® & XiVE® S FRIADENT® CeraBase Fine Diamond Drill .Order No. 45 – 5605 Article FRIADENT® Seating Instrument for Transfer Coping and MH-6 Abutment /A 0 FRIADENT® Finisher6/10 for Horizontal Screw Seat FRIADENT® Hermetics Basic Set (Seating Instrument.4 – D 4. Fine Diamond Drill. DENTSPLY Friadent accepts the obligation to apply new scientific insights to the development of existing and new implant systems. XiVE® TG plus is the result of the scientific and clinical experience accumulated with the New Ledermann Screw and FRIALOC® systems.XiVE TG ® XiVE® TG plus – the transgingival alternative If function is the first priority. the transgingival implant looks like a XiVE® S plus implant with an integrated MP abutment. As a leader in innovation. 66 . then the single-component transgingival XiVE® TG plus implant is recommended. With the implant-abutment connection and the machined implant collar extending through the soft tissue. Indications Cases: ■ where a transgingival implant design is indicated ■ when temporary and definitive components are needed for simple and fast prosthetic restoration ■ requiring increased primary stability for early or immediate implant function ■ with atrophied ridges where augmentation is not desired or indicated. even in spongy bone. 67 XiVE® TG Growth-activating FRIADENT® plus surface. Nano-design Implant diameter D 3. Previously placed FRIALOC® implants can still be restored with components of the XiVE® TG prosthetic line.8 Ȝ D 4.5 Ȝ The XiVE® TG product range is a further development of the FRIALOC® implant system. . Transgingival Screw implant with trimodal surface morphology providing an ideal environment for functional adaptation of epithelium. All XiVE® TG components and instruments (except the drills) are fully compatible with FRIALOC®. Micro-design The innovative thread design of XiVE® screw implants combined with the bone-class-specific preparation of the implant site provides torque stabilization in all bone qualities.4 XiVE® TG Ȝ D 3. multiple implant restorations in posterior regions ■ where a cylindrical implant design is advantageous – particularly in the lateral region ■ where the local bone must be used to the maximum possible extent: implant lengths available range from 8 to 18 mm Macro-design The cylinder-shaped design for internal condensation of the peri-implant bone prevents trauma and increases primary stability of implants. connective tissue and bone. 2. ■ Transparent outer vial – to see the content Color-coded cap displaying the implant length – for clear identification Sterile inner vial with implant retaining stopper – for fast and safe no-touch placement of implants Peel-off labels – for a reliable documentation ■ ■ ■ 3. Remove the implant without touching the inner vial. transparent double vials. The undamaged label clearly indicates that the sterile package has not been opened and thus product sterility. Place the XiVE® TG Ratchet or Handpiece Implant Driver onto the Adapter Screw. Remove the outer vial cap (non-sterile) and drop the sterile inner vial onto the surgical tray. All FRIADENT® Screw Implants are packed in gamma sterilized.Implant placement XiVE® TG sterile packaging for implants No-touch insertion XiVE® TG plus Transgingival Screw Implant 1. Place XiVE® TG plus Screw Implant. 68 . 4. 5. The color-coded cap is sealed with an adhesive label. Please follow the instructions for use. Remove the Implant Holder. 4/L 3.4/L 3.Order No.8/L 3.8/L 4. Adapter Screw 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 – – – – – – – – – – – – – – – – – 1431 1432 1433 1435 1438 1440 1441 1442 1443 1445 1448 1450 1451 1452 1453 1455 1458 – – – – – – – – – – – – – – – – – ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD ȜD 3.9 mm FRIADENT® Hex Driver.5/L 4.5 11 13 15 18 8 9.5/L 4. 25 – 9200 XiVE® TG Clinical Set Cover Screw (Four Cover Screws) 25 – 1400 Ȝ Ȝ Ȝ XiVE® TG Cover Screw for Implants2 The Cover Screws are placed with the 0.4/L 3.5/L 9.5 11 13 15 18 8 9. the Adapter Screw is removed with the 0. the same components as for XiVE®S Screw Implants are used (see pages 22/23).8/L 3.5 11 13 15 18 An Adapter Screw is pre-mounted on XiVE® TG plus Screw Implants to secure the Implant Driver. Article For the pre-surgical planning of XiVE®TG plus.5/L 4.4/L 3. Implants (sterile) XiVE® TG plus Transgingival Screw Implant Screw Implant3.4/L 3. Use the XiVE® TG Ratchet or Handpiece Implant Driver (see page 76) to thread in the XiVE® TG Implants.5/L 4. After rotating in the implant.9 mm FRIADENT® Hex Driver.8/L 3.8/L 3. 69 XiVE® TG .8/L 3.5/L 4. 26 – 8000 26 – 8005 XiVE® ExpertSet Surgery5/6/26 XiVE® StandardSet Surgery5/6/26 Drills and drill sequence for transgingival XiVE® TG Implants are identical to those of subgingival XiVE® S Implants (see page 28/29).22 mm/24 Ncm/long FRIADENT Handpiece Hex Driver6 – width 0.9 mm/short – width 0.Instruments Order No.22 mm/24 Ncm/short – width 1. Article XiVE® Instrument Sets Surgery The XiVE® Instrument Sets Surgery contain the instruments required for implant placement (see page 30). The kits are supplied in the XiVE® Surgical Tray.22 mm/short – width 1.9 mm/14 Ncm/long – width 1.22 mm/long 45 45 45 45 – – – – 5732 5733 5734 5736 46 46 46 46 – – – – 5710 5720 5711 5721 70 . XiVE® BoneCondenser may also be used (see page 35).9 mm/14 Ncm/short – width 0. without inserts XiVE® TG Ratchet Implant Driver6 XiVE® TG Handpiece Implant Driver6 FRIADENT Ratchet Hex Driver6 with torque limit – width 0. Other Instruments 25 – 5206 45 – 5709 25 – 5600 25 – 5601 XiVE® TG Radiographic Template (transgingival) FRIADENT® Ratchet6.9 mm/long – width 1. Previously placed FRIALOC® implants can still be restored with components of the XiVE® TG prosthetic line. 71 XiVE® TG . Titanium or Castable Bar Coping XiVE® TG PickUp Impression Coping XiVE® TG AuroBase XiVE® TG Waxing Sleeves XiVE® TG Attachment The XiVE® TG product range is a further development of the FRIALOC® implant system.XiVE® TG Prosthetics Components are selected based on the prosthetic concept. Impressions Single Crowns Bridges Overdentures XiVE® TG Transfer Impression Coping XiVE® TG Abutment straight or angled 15° XiVE® TG Abutment straight or angled 15° XiVE® TG Gold. All XiVE® TG components and instruments (except the drills) are fully compatible with FRIALOC®. please use the FRIADENT® MP Transfer Impression Coping D 3.4 – D 4.5 (Four Transfer Impression Copings ) 25 – 9105 Ȝ Ȝ Ȝ XiVE® TG Clinical Set Transfer Impression (short) D 3. 72 . 25 – 1805 Ȝ Ȝ Ȝ XiVE® TG PickUp Impression Coping2 D 3.5 (Four Short Transfer Impression Copings) 25 – 9112 Ȝ Ȝ Ȝ XiVE® TG Clinical Set PickUp Impression D 3. 46 –1640.5 with PickUp Guide Pin Ȝ Ȝ Ȝ XiVE® TG PickUp Guide Pin4 25 – 1701 If. in cases of implant divergencies.4 – D 4.5 Ȝ Ȝ Ȝ XiVE® TG Transfer Impression Coping (short)2 D 3. Article 25 – 9100 Ȝ Ȝ Ȝ XiVE® TG Clinical Set Transfer Impression D 3.5 (Four PickUp Impression Copings with four TG PickUp Guide Pins) 25 – 1600 Ȝ Ȝ Ȝ XiVE® TG Transfer Impression Coping2 D 3. a transfer of the square head is not required.4 – D 4.4 – D 4.8 (Order no. see page 57).4 – D 4.5 25 – 1605 The short Impression Copings are used for making the impression with an existing prosthesis.Impressions Order No.4 – D 4. This impression coping is compatible with all diameters of XiVE® TG. 4 – D 4.5 (Four TG Cast-to Waxing Sleeves.5 TG Implant-Soldering Analog with TG Abutment Screw 25 – 4105 The TG Soldering Analog is used for securing the framework in the soldering base.5 with TG Abutment Screw 25 – 4300 Ȝ Ȝ Ȝ XiVE® TG Abutment Screw4 D 3.5 Soldering Analogs 25 – 9305 Ȝ Ȝ Ȝ XiVE® TG Lab Set Implant-Soldering Analog (Bridge) D 3.Prosthetics/laboratory Order No. four TG Abutment Screws) Ȝ Ȝ Ȝ XiVE® TG Lab Set Soldering Analog Bridge D 3.4 – D 4.5 (Four TG Implant-Soldering Analogs) 25 – 4010 Ȝ Ȝ Ȝ XiVE® TG Implant-Soldering Analog6 D 3.4 – D 4. 73 XiVE® TG 25 – 4246 Ȝ Ȝ Ȝ XiVE® TG Cast-to Waxing Sleeve21/8 D 3. four TG Abutment Screws) 25 – 9905 Ȝ Ȝ Ȝ XiVE® TG Lab Set Bridge (Cast-to Waxing Sleeve) D 3.5 (Four TG Implant-Soldering Analogs. four TG Abutment Screws) 25 – 4245 Ȝ Ȝ Ȝ XiVE® TG Castable Waxing Sleeve21 D 3. Article 25 – 9900 Ȝ Ȝ Ȝ XiVE® TG Lab Set Bridge (Castable Waxing Sleeve) D 3.4 – D 4.4 – D 4. Article 25 – 9405 Ȝ Ȝ Ȝ XiVE® TG Implant-Soldering Analog Multipack D 3.5 Bridges Order No.4 – D 4.4 – D 4.5 with TG Abutment Screw IMZ-TwinPlus .4 – D 4.5 (Four TG Castable Waxing Sleeves.4 – D 4. 4 – D 4. An additional horizontal or transverse screw set is necessary for horizontally screw-retained crowns (see page 51).4). 25 – 4520 Ȝ Ȝ Ȝ XiVE® TG AuroBase20/8 D 3.4 – D 4.4 – D 4. 25 – 4500 Article Ȝ Ȝ Ȝ XiVE® TG Abutment straight2 D 3.Prosthetics/laboratory Bridges and single crowns Order No.5 (straight) with TG Abutment Screw Ȝ Ȝ Ȝ XiVE® TG Abutment angled 15°2 D 3. Lemgo or Jota Düsseldorf) for preparing the abutments.5 with TG Abutment Screw Ȝ Ȝ Ȝ XiVE® TG Abutment Screw4 25 – 4300 25 – 4401 Ȝ Ȝ Ȝ XiVE® TG Attachment2/4 D 3.5 74 .5 (angled 15°) with TG Abutment Screw 25 – 4510 All straight and angled TG Abutments are provided with a horizontal thread (M 1.4 – D 4. We recommend the use of special titanium drills (Gebr. Brasseler. 4 – D 4.4 – D 4.5 with TG Coping Screw Ȝ Ȝ Ȝ XiVE® TG Titanium Bar Coping2 D 3.5 (Four TG Castable Copings.5 TG Implant-Soldering Analog with TG Coping Screw 75 XiVE® TG FRIADENT Gold Bar round9 50 mm length IMZ-TwinPlus .4 – D 4. four TG Coping Screws) 25 – 4240 Ȝ Ȝ Ȝ XiVE® TG Gold Bar Coping9 D 3.4 – D 4.5 with TG Coping Screw Ȝ Ȝ Ȝ XiVE® TG Castable Bar Coping21 D 3.4 – D 4. Article 25 – 9600 Ȝ Ȝ Ȝ XiVE® TG Lab Set Gold Bar Coping9 D 3.5 (Four TG Titanium Copings. four TG Coping Screws) 25 – 9700 Ȝ Ȝ Ȝ XiVE® TG Lab Set Titanium Bar Coping D 3.4 – D 4.4 – D 4. four TG Coping Screws) 25 – 4106 Ȝ Ȝ Ȝ XiVE® TG Lab Set Soldering Analog Bar D 3. four TG Coping Screws) 25 – 9800 Ȝ Ȝ Ȝ XiVE® TG Lab Set Castable Coping D 3.Overdentures Order No.4 – D 4.5 (Four TG Gold Copings.5 with TG Coping Screw Ȝ Ȝ Ȝ XiVE® TG Coping Screw4 25 – 4241 25 – 4242 25 – 4200 Accessories 45 – 4210 45 – 4212 45 – 4215 FRIADENT Titanium Bar round2 50 mm length FRIADENT Gold Bar Clip9 50 mm length Soldering Analogs 25 – 9306 Ȝ Ȝ Ȝ XiVE® TG Lab Set Implant-Soldering Analog (Bar) D 3.5 (Four TG Implant-Soldering Analogs. 9 mm/short – width 0.22 mm/short – width 1.22 mm/long FRIADENT® Handle for Handpiece Hex Driver6 45 45 45 45 – – – – 5732 5733 5734 5736 46 46 46 46 – – – – 5710 5720 5711 5721 46 – 5750 This handle fits all handpiece drivers.Instruments for impression/ prosthetics/laboratory Order No. without inserts FRIADENT Ratchet Hex Driver6 with torque limit – width 0.9 mm/14 Ncm/short – width 0.22 mm/24 Ncm/long FRIADENT Handpiece Hex Driver6 – width 0.22 mm/24 Ncm/short – width 1. 45 – 5709 Article FRIADENT® Ratchet6.9 mm/14 Ncm/long – width 1. 25 – 5705 XiVE TG Finisher 76 .9 mm/long – width 1. 77 XiVE® TG . FRIALIT® BoneProfiler CD-ROM FRIALIT® MP-Abutment CD-ROM FRIALIT® Select CD-ROM XiVE®. PowerPoint presentation Videos 66 – 4046 66 – 4047 5 – 701012 FRIALIT® System Video (English. Picture CD FRIALIT®/XiVE® CD-ROM. NTSC) Implant Passport XiVE® 78 . PowerPoint presentation CD-ROM FRIADENT® plus. PowerPoint presentation and slides CD-ROM FRIALIT® Video Sequences in PowerPoint CD-ROM. 45 – 9992 45 – 9981 45 – 9982 45 – 9985 45 – 9986 26 – 9110 Article Large scale model FRIALIT® Synchro 5 :1 (with crown) FRIADENT® Acrylic model maxilla without prosthetics (ANKYLOS®. XiVE®) FRIADENT® Acrylic model maxilla with prosthetics (ANKYLOS®. all Systems CD-ROM CERCON®. Picture CD DENTSPLY Friadent CD-ROM. Picture CD CERCON® plus CD-ROM. XiVE®) XiVE® Acrylic model mandible without prosthetics (bar construction) XiVE® Acrylic model mandible with prosthetics (bar construction) XiVE® Large Scale Model Set 5:1 CD-ROMs for Presentation Each CD-ROM contains Powerpoint Presentations and high-resolution picture files for the exposing of slides 66 – 1035 66 – 4037 66 – 4038 66 – 4039 66 – 7010 66 – 4036 66 – 4501 66 – 1036 66 – 1037 66 – 1038 66 – 1067 66 – 1066 CD-ROM FRIALIT® Basics Surgery and Prosthetics CD-ROM FRIALIT® Synchro.Presentation material Order No. FRIALIT®. Picture CD Internet. PAL) FRIALIT® System Video (English. FRIALIT®. Ir: 1% Au: 68.9 x 10-6 K-1.6%.1%. Ir: 0. Zn: 2. Ag: 11. Cu: 10.5% K 40 * TEC 11. Pd: 4%. cast temperature < 1450°C ** melting interval from 880 – 940°C Plastics Type Polyoxymethylene Polymethylmethacrylate Polystyrene Polytetrafluourethylene Polyetheretherketone Polyetherimide Silicone Polycarbonate Polypropylene Index 20 21 22 23 24 25 26 27 28 Ceramics Typ Aluminium oxide Hydroxyapatite Zirconium oxide Index 30 31 32 Composition Al2O3 Ca5(PO4)3OH ZrO2 79 Presentation material . Pd: 20%. pre-heating temperature < 850°C.6%.4305 CuZn Au: 60%.Materials Metals Type Titanium Titanium Titanium Titanium Aluminium Stainless steel Brass Cast-to alloy* Gold alloy ** Hard metal Index 1 2 3 4 5 6 7 8 9 10 Composition Ti grade 1 Ti grade 2 Ti grade 4 Ti6AL4V AlMg3 DIN 1.4%.8%. Pt: 2. Pt: 19%. 80 . 81 . 82 . O. membranes.FRIADENT Class l Medical Devices In terms of the Directive 93/42/EEC Class l Medical Devices are: – Non-active hand-held surgical and prosthetic instruments for implant placement and augmentation – Components for impression technique. Box 71 01 11 · 68221 Mannheim/Germany Phone: + 49 621 4302-1288 · Fax: + 49 621 47 13 06 e-Mail: info@friadent. membrane nails as well as bone reconstruction materials – Active surgical and prosthetic instruments for implant placement and augmentation – Components for impression technique and prosthetic overdenture. which do not remain in the patient’s mouth – Non-active components for the planning stage FRIADENT Class lla. llb and lll Medical Devices are: – Dental Implants.de 83 . which remain in the patient’s mouth Manufacturer: FRIADENT GmbH · P. llb and lll Medical Devices 0123 In terms of the Directive 93/42/EEC Class lla.de · Internet: http://www.friadent. O.de · Internet: http://www.friadent.de .Order No. 6-452001/009 060709/SB Manufacturer: FRIADENT GmbH · P. Box 71 01 11 · 68221 Mannheim/Germany Phone: + 49 621 4302-1288 · Fax: + 49 621 47 13 06 e-Mail: info@friadent.
Copyright © 2024 DOKUMEN.SITE Inc.