British Standards for ParticleboardPanel Guide produced by Wood Panel Industries Federation, Timber Trade Federation, TRADA & BRE & National Green Specification – August 2006 According to the both the Panel Guide and NGS (National Green Specification) - an independent organisation partnered with the Building Research Establishment to provide information to those involved with ‘Sustainable Construction’ - the current British Standard for specifying particleboard is BS EN 312:2003. BS EN 312:2003: Particleboards. Specifications There are various types of board defined in BS EN 312 which indicate the range of use conditions of particleboard, with common applications including flooring, kitchen units and worktops, furniture and shopfitting. The 2003 version of this standard, replaced the previous 1997 version of BS EN 312, which was issued in seven parts. BS EN 312 specifies the requirements for particleboards to be used in dry and humid conditions, as particleboard is not normally suitable for exterior applications. With the introduction of the 2003 version of this standard a new grade of particleboard was introduced. This new grade was termed P3 and is intended to be a moisture resistant non-load bearing board, which should reduce the risk of moisture failure compared with the alternative grade P2. The basic mechanical properties of particleboard are controlled by BS EN 312 and design characteristic values for use of the load-bearing grades with Eurocode 5 are given in BS EN 12369-1. According to the Panel Guide, Cement Bonded Particleboard manufactured in Europe must be specified in accordance with the European standard EN 634. The UK version of this standard is BS EN 634. This standard states that particleboard can be bonded with Ordinary Portland Cement (OPC) or with magnesium-based cements. This standard has two parts: BS EN 634-1: Cement-bonded particleboards – Specifications – Part 1: General Requirements BS EN 634-2: Cement-bonded particleboards – Specifications – Part 2: Requirements for OPC bonded particleboards for use in dry, humid and exterior conditions. The second part of this standard BS EN 634:2 relates only to Ordinary Portland Cement Cement Bonded Particleboard Board. These boards have a very high durability and are suitable for use in dry, humid or exterior conditions. Their high density gives them good acoustic and fire performance. They are used for flooring, modular buildings and applications where high durability is required. The Panel Guide also states that Cement Bonded Particleboard that is used in construction must, by law, comply with the Harmonised Standard for wood-based panels which is BS EN 13986. British Standards Institute – August 2006 Analysis of the British Standard Institute’s listings have identified the following standards for Particleboard: Standard Number BS EN 1087-1:1995 BS EN 634-1:1995 BS EN 634-2:1997 BS EN 319:1993 BS EN 335-3:1996 BS EN 123691:2001 BS EN 14322:2004 BS EN 13986:2004 BS EN 317:1993 Title Particle boards. Determination of moisture resistance. Particle boards. Determination of moisture resistance. Boil test Cement-bonded particle boards. Specification. General requirements Cement-bonded particle boards. Specification. Requirements for OPC bonded particleboards for use in dry, humid and exterior conditions Particleboards and fibreboards. Determination of tensile strength perpendicular to the plane of the board Hazard classes of wood and wood-based products against biological attack. Application to wood-based panels Wood-based panels. Characteristic values for structural design. OSB, particleboards and fireboards Wood-based panels. Melamine faced boards for interior uses. Definition, requirements and classification Wood-based panels for use in construction. Characteristics, evaluation of conformity and marking Particleboards and fibreboards. Determination of swelling in thickness after Status Confirmed, Current Confirmed, Current Current, Work in Hand Current Current Current Current Current Confirmed, Current immersion in water BS 6100-4.3:1984 Glossary of building and civil engineering terms. Forest products. Wood based panel products Eurocode 5. Design of timber structures. General. Common rules and rules for buildings Particleboards. Definition and classification Structural use of timber. Code of practice for permissible stress design, materials and workmanship Cement bonded particleboards. Determination of frost resistance Wood-based panels. Surface soundness. Test method Particleboards. Specifications Extruded particleboards. Specifications Cement-bonded particleboards. Definition and classification Cement-bonded particleboards. Determination of hard body impact resistance Oriented strand boards (OSB). Definitions, classification and specifications prEN 12869-1. Wood-based panels. Structural floor decking on joists. Part 1. Performance specifications prEN 12869-2. Wood-based panels. Structural floor decking on joists. Part 2. Performance requirements prEN 12870-1. Wood-based panels. Structural wall sheathing on studs. Part 1. Performance specifications ISO 17064. Wood-based panels. Fibreboard and particleboard. Vocabulary EN 300. Oriented strand boards (OSB). Definitions, classification and specifications BS EN 634-2. Cement-bonded particleboards. Specifications. Part 2. Requirements for OPC bonded particleboards for use in dry, humid and external conditions ISO 16893-1. Wood-based panels. Particleboard. Part 1. Classifications Current, Proposed for Confirmation, Work in Hand Current Current Current, Work in Hand Current Current Current Current Confirmed, Current Confirmed, Current Current, Work in Hand Current, Draft for Public Comment Current, Draft for Public Comment Current, Draft for Public Comment Current, Draft for Public Comment Current, Draft for Public Comment Current, Draft for Public Comment Current, Draft for Public Comment BS EN 1995-11:2004 BS EN 309:2005 BS 5268-2:2002 BS EN 1328:1997 BS EN 311:2002 BS EN 312:2003 BS EN 14755:2005 BS EN 633:1994 BS EN 1128:1996 BS EN 300:1997 97/103065 DC 97/103066 DC 97/103067 DC 03/305686 DC 04/30113724 DC 05/30132017 DC 06/30146208 DC British Standards for profile products British Standards Institute – June 2006 Due to the number of various products and varying names given to the types of products produced by Likov, analysis of the British Standards Institute was carried out by searching for key terms to describe Likov products. The following is a list of the key terms that were used to find British Standards which could be applicable to Likov products: Search Terms: +bead +plaster Standard Number BS 6452-1:1984 Title Beads for internal plastering and dry lining. Specification for galvanized steel beads Status Current, Proposed for Confirmation Current BS EN 13658-1:2005 Metal lath and beads. Definitions, requirements and test methods. Internal plastering Search Terms: +construction +joint +filler Standard Number Title Status Design of joints and jointing in building construction. General technical specifications for single taps and mixer taps (nominal size 1/2) PN 10.05 MPa (0. Particular requirements for clothes dryers and towel rails. Work in Hand Current. and a minimum flow pressure of 0. Method of measurement Sanitary tapware. General specifications for flow rate regulators Status Current BS EN 816:1997 BS EN 200:1992 BS EN 1113:1997 BS EN 1111:1999 BS EN 1286:1999 BS 7942:2000 BS EN ISO 38221:1999 BS EN 1287:1999 BS EN 246:2003 Current Current. and shower heads. Automatic shut-off valves PN 10 Sanitary tapware. Thermostatic mixing valves (PN 10). Part 2-43 Particular requirements for clothes dryers and towel rails IEC 60335-2-43 A1. Low pressure mechanical mixing valves. British Standards Institute – June 2006 Analysis of the British Institute website has identified the following British Standards for Towel rails. Household and similar electrical appliances. General technical specifications Sanitary tapware. Draft for Public Comment British Standards for Bathroom Taps: Standard Number BS 5412:1996 Title Specification for low-resistance single taps and combination tap assemblies (nominal size ½ and ¾) suitable for operation at PN 10 max. Draft for Public Comment British Standards for bathroom products The Bathroom Manufacturers Association – May 2006 The Bathroom Manufacturers Association (BMA) is the trade association for manufacturers of bathroom products trading in the UK. According to the Bathroom Manufacturers Association the main British Standards for shower heads are as follows: BSEN 1112: Shower outlets High Pressure BSEN 13904: Shower outlets Low Pressure BSEN 1113: Shower hoses High Pressure BSEN 13905: Shower hoses Low Pressure The Bathroom Manufacturers Association do not believe there are any British Standards in place for bathroom shelving. Laboratory tests on noise emission from appliances and equipment used in water supply installations.5 bar) Shower hoses for (PN 10) sanitary tapware Sanitary tapware. Part 2-43. British Standards for Towel Rails: Standard Number BS EN 60335-243:2003 04/30109592 DC Title Specification for safety of household and similar electrical appliances. Work in Hand Current. Guide Current. taps. Minimum flow pressure of 0. Particular requirements for appliances for clothes dryers and towel rails Status Current. Safety. Low pressure thermostatic mixing valves.01 MPa (0. soap dishes and these type of bathroom accessories. General technical specification Sanitary tapware. 1 bar) Sanitary tapware.BS 6093:1993 06/30147091 DC Code of practice for design of joints and jointing in building construction BS 6093. Work in Hand Current Current Current Current Current Current Current . General technical specification Thermostatic mixing valves for use in care establishments Acoustics. Sanitary tapware. these include British and other standards and are as follows: Applicable British and other Standards BS 1245:1975 Specification for metal door frames (steel) BS 3621:2004 Thief resistant lock assemblies . General technical specifications Current Current Current Current Current. Test method BS EN 12428:2000 Industrial. Mechanical mixers (PN 10). Air permeability. Thermal transmittance. Methods for determination of the fire resistance of non-loadbearing elements of construction BS EN 12426:2000 Industrial. Requirements for the calculation BS EN 12444:2001 BS EN 61000-6-2:2001 Electromagnetic compatibility (EMC). Method for determination of the fire resistance of elements of construction (general principles) BS 476-22:1987 Fire tests on building materials and structures. Single taps and combination taps (PN 10). Generic standards. Classification BS EN 12427:2000 Industrial. Air permeability. Mechanical mixers (PN 10). Draft for Public Comment Current. Part 3. Sanitary tapware.Key egress BS 476-20:1987 Fire tests on building materials and structures. Draft for Public Comment British Standards for Shower Heads/Hoses: Standard Number BS 6340-4:1984 BS EN 1112:1997 BS EN 1113:1997 Title Shower units. Specification for shower heads and related equipment Shower outlets for (PN 10) sanitary tapware Shower hoses for (PN 10) sanitary tapware Status Current Current Current British Standards for Security Doors The Door & Hardware Federation – May 2006 The Door & Hardware Federation (DHF) was created by a merger between the Association of Building Hardware Manufacturers and the Door & Shutter Manufacturers Association. The DHF has established six specialist groups: • • • • • • Building Hardware Group Drive & Control Group Garage Door Group Industrial Door Group Metal Doorset Forum Repair & Service Group According to the DHF there are a number of standards which cover the products of Security Doors. Immunity standard for industrial environments BS EN 60335-2-95:2001 Safety of electrical appliances Particular requirements for drives for vertically-moving garage doors BS EN 60335-2-97:2001 Safety of electrical appliances Particular requirements for drives for rolling shutters. commercial and garage doors and gates. General technical specification EN 817. awnings. commercial and garage doors and gates.BS EN 248:2002 BS EN 695:2005 BS EN 13904:2003 BS EN 13905:2003 BS EN 817:1998 96/105590 DC 02/101511 DC 05/30127036 DC Sanitary tapware. commercial and garage doors and gates. and Garage Doors. Work in Hand Current. General technical specifications Specification for installations inside buildings conveying water for human consumption. Draft for Public Comment Current. General specification for electrodeposited coatings of Ni-Cr Kitchen sinks. DHF represents the interests of manufacturers and installers of industrial. pedestrian and garage doors as well as manufacturers of locks and building hardware. Connecting dimensions Low resistance shower outlets for sanitary tapware Low resistance shower hoses for sanitary tapware Sanitary tapware. blinds &c . Security Shutters. Pipe sizing (prEN 806-3) BS EN 200. Test methods BS EN 12453:2001 Industrial.Offices and shops BS 8220-3:2004 Guide for security of buildings against crime . Safety in use of power operated doors.Part 2 .Fittings for espagnolette bolts DD CEN/TS 13126-4:2004 Fittings for windows . Mechanical aspects. Emission standard for residential. commercial and garage doors and gates.Sash balances DD CEN/TS 13126-14:2004 Fittings for windows .1:1983 Fire tests on building materials and structures. See also DD 9999:2005 BS 6375-1:2004 Performance of windows and doors. Mechanical aspects.Products w/out fire/smoke resistance BS EN 13724:2002 Apertures of private letter boxes and letter plates. commercial and garage doors and gates Product standard . Testing and calculation BS EN 12445:2001 Industrial. Test methods BS EN 12635:2002 Industrial. industrial and distribution premises BS 8424:2004 Building hardware.Part 3: Storage. Requirements BS EN 12489:2000 Industrial.Espagnolette bolts .Side hung projecting reversible hardware DD CEN/TS 13126-13:2004 Fittings for windows . Installation and use BS EN 1294:2000 Door leaves .Fittings for tilt and slide systems DD CEN/TS 13126-2:2004 Fittings for windows .Casement fastener handles DD CEN/TS 13126-3:2004 Fittings for windows . Requirements and test methods BS EN 14600:2005 BS EN 61000-6-3:2001 Electromagnetic compatibility (EMC). Resistance to wind load. commercial and garage doors and gates. Requirements and test methods BS EN 1303:2005 Cylinders for locks BS EN 13241-1:2003 Industrial. commercial and garage doors and gates. Code of practice for wind loads BS 8220-1:2000 Guide for security of buildings against crime . Generic standards. Safety in use of power operated doors.Rollers DD CEN/TS 13126-16:2004 Fittings for windows .Common requirements DD CEN/TS 13126-10:2004 Fittings for windows . construction and use of buildings DD CEN/TS 13126-1:2004 Fittings for windows . Classification for weathertightness and guidance on selection and specification BS 6399-2:1997 Loading for buildings. Some have now been withdrawn.Fittings for lift and slide systems DD CEN/TS 13126-17:2004 Fittings for windows . Pull handles. commercial and garage doors and gates.Arm balancing systems DD CEN/TS 13126-11:2004 Fittings for windows . commercial and garage doors and gates. commercial and garage doors and gates. construction and use of buildings. Safety devices for power operated doors and gates. Resistance to water penetration.Keyless egress BS EN 1125:1997 Panic exit devices operated by a horizontal bar BS EN 1154:1997 Controlled door closing devices BS EN 1155:1997 Electrically powered hold open devices for swing doors BS EN 1158:1997 Door coordinator devices BS EN 12046-2:2000 Doors . Requirements BS EN 12605:2000 Industrial.Sash fasteners DD CEN/TS 13126-15:2004 Fittings for windows .Operating forces . commercial and garage doors and gates. Methods for measuring smoke penetration through doorsets and shutter assemblies. Various parts published from 1984 onwards. Requirements and test methods BS 8621:2004 Thief resistant lock assemblies . Method of measurement under ambient temperature conditions BS 5588 Fire precautions in the design. commercial and garage doors and gates.Top hung projecting reversible hardware DD CEN/TS 13126-12:2004 Fittings for windows .BS 476-31.Behaviour under humidity variations BS EN 12978:2003 Industrial.Part 1 . commercial and light-industrial environments DD 171:1987 Guide to specifying performance requirements for hinged or pivoted doors (including test methods) DD 9999:2005 Code of practice for fire safety in the design.Dwellings BS 8220-2:1995 Guide for security of buildings against crime .Test method BS EN 12051:2000 Door and window bolts Industrial. Test method BS EN 12604:2000 Industrial. Classification BS EN 12425:2000 Industrial. shutters.Bullet resistance BS EN 1527:1998 Hardware for sliding doors and folding doors BS EN 1529:2001 Door leaves . Smoke control doors and shutters BS EN 1670:1998 Building hardware . General requirements BS EN 60335-2-103:2003 Safety of electrical appliances Particular requirements for drives for gates.Watertightness Classification BS EN 12209:2003 Mechanically operated locks.Air permeability Classification BS EN 12208:2000 Windows and doors . doors.Requirements and Classification BS EN 12320:2001 Padlocks and padlock fittings BS EN 12400:2002 Windows and pedestrian doors Mechanical durability . Test method for determination of resistance under dynamic loading DD ENV 1630:1999 BS EN 1906:2002 Lever handles and knob furniture BS EN 1935:2002 Single axis hinges BS EN 1991-1-4:2005 Eurocode 1. doors and windows Windows.Test method BS EN 12217:2003 Doors . doors.BS EN 12207:2000 Windows and doors . Burglar resistance.Resistance to windload . General requirements BS EN 60335-1:2002 Specification for safety of household and similar electrical appliances. General actions. Burglar resistance.General and local flatness BS EN 1634-1:2000 Fire resistance tests for door and shutter assemblies BS EN 1634-3:2004 Fire resistance tests for door and shutter assemblies.Height. commercial and garage doors and gates. Burglar resistance. shutters. width.Variable geometry stay hinges DD CEN/TS 13126-7:2004 Fittings for windows .Resistance to windload . Actions on structures.Classification BS EN 12211:2000 Windows and doors . Wind actions BS EN 60204-1:1998. Classification Doorsets and openable windows with fire-resisting and/or smoke control characteristics Requirements and classification BS EN 1522:2001 Windows. Test method for the determination of resistance under static loading DD ENV 1629:1999 Windows. shutters.Operating forces .Corrosion resistance BS EN 179:1997 Emergency exit devices DD CEN/TS 13126-5:2004 Fittings for windows . external door assemblies to dwellings PAS 24-1:1999 Enhanced security performance requirements for door assemblies. latches and striking plates BS EN 12210:2000 Windows and doors . shutters.Opening restrictors DD CEN/TS 13126-6:2004 Fittings for windows . Single leaf.Pivot hinges DD ENV 1627:1999 Windows. Resistance to water penetration. doors &c . IEC 60204-1:1997 Safety of machinery. hinged external door assemblies to dwellings .Climatic Influences . Electrical equipment of machines. doors.Requirements and Classification BS EN 12424:2000 Industrial. Test method for the determination of resistance to manual burglary attempts PAS 23-1:1999 General performance requirements for door assemblies. commercial and garage doors and gates. Single and double leaf.Finger catches DD CEN/TS 13126-8:2004 Fittings for windows .Requirements and classification BS EN 12219:2000 Doors . Resistance to wind load. doors.Tilt & turn &c hardware DD CEN/TS 13126-9:2004 Fittings for windows . Requirements and classification DD ENV 1628:1999 Windows. thickness and squareness BS EN 1530:2001 Door leaves . Burglar resistance. ATM safes. Draft for Public Comment Current. Electrically controlled emergency exit systems for use on escape routes. Locks and latches. classification and methods of test for resistance to burglary.British Standards Institute – June 2006 Analysis of the British Standard Institute’s listings have identified the following standards for Security Doors: Standard Number BS 82202:1995 BS 5357:1995 BS EN 1522:1999 BS EN 1523:1999 BS 82203:2004 BS 82201:2000 BS EN 12051:2000 BS EN 8171:2005 BS EN 12209:2003 BS EN 11431:2005 BS 3621:2004 PAS 24-1:1999 BS 565513:1995 BS EN 1125:1997 BS EN 179:1998 BS 2881:1989 99/104967 DC 99/104966 DC 03/102518 DC Title Guide for security of buildings against crime. Key egress Enhanced security performance requirements for door assemblies. Requirements and test methods (prEN 13633) BS EN 13637. Recommendations for vandal resistant lifts Building hardware. Electronically controlled panic exit systems. Requirements and test methods Specification for cupboards for the storage of medicines in health care premises Building hardware. Requirements and test methods Building hardware. Requirements and classification Windows. Bullet resistance. doors. Dwellings Building hardware. Superseded Current. Single and double leaf. latches and locking plates. Vandal resistant lifts Building hardware. Mechanically operated locks. Work in Hand Current. hinged external door assemblies to dwellings Lifts and service lifts. Offices and shops Code of practice for installation of security glazing Windows. Emergency exit devices operated by a lever handle or push pad. Requirements and test methods Secure storage units. Particular applications to passenger lifts and goods passenger lifts. Door and window bolts. Draft for Public Comment British Standards for Security Shutters/Garage Doors: The Door & Hardware Federation – May 2006 The Door & Hardware Federation (DHF) was created by a merger between the Association of Building Hardware Manufacturers and the Door & Shutter Manufacturers Association. Storage. Requirements and test methods Safety rules for the construction and installation of lifts. Current Current. Requirements and test methods (prEN 13637) Building hardware. Bullet resistance. Work in Hand Confirmed. doors. Safes. Requirements and test methods Status Current Current Current Current Current Current Current Current Current Current Current Current Current. strongroom doors and strongrooms Thief resistant lock assemblies. Test method Guide for security of buildings against crime. Electronically controlled emergency exit systems. Building hardware. shutters and blinds. DHF represents the interests of manufacturers and installers of industrial. pedestrian and garage doors as well as manufacturers of locks and building hardware. industrial and distribution premises Guide for security of buildings against crime. Draft for Public Comment Current. Requirements. Panic exit devices operated by a horizontal bar. shutters and blinds. The DHF has established six specialist groups: . 1:1983 Fire tests on building materials and structures. See also DD 9999:2005 BS 6375-1:2004 Performance of windows and doors. Mechanical aspects. Generic standards. Resistance to wind load. Test method BS EN 12428:2000 Industrial.Side hung projecting reversible hardware DD CEN/TS 13126-13:2004 Fittings for windows . commercial and garage doors and gates. Various parts published from 1984 onwards. commercial and DD 9999:2005 Code of practice for fire safety in the design. industrial and distribution premises BS EN 12426:2000 Industrial. Requirements for the calculation BS EN 12444:2001 Industrial. Test methods BS EN 12635:2002 Industrial. construction and use of buildings DD CEN/TS 13126-1:2004 Fittings for windows . commercial and garage doors and gates.Offices and shops BS 8220-3:2004 Guide for security of buildings against crime . Some have now been withdrawn.Common requirements DD CEN/TS 13126-10:2004 Fittings for windows . Security Shutters. commercial and garage doors and gates. Requirements BS EN 12489:2000 Industrial.Part 3: Storage. Classification BS EN 12427:2000 Industrial. Methods for measuring smoke penetration through doorsets and shutter assemblies. Methods for determination of the fire resistance of non-loadbearing elements of construction BS 476-31.Dwellings BS 8220-2:1995 Guide for security of buildings against crime . blinds &c . commercial and garage doors and gates. Thermal transmittance.Part 1 . commercial and garage doors and gates. awnings. commercial and garage doors and gates.Key egress BS 476-20:1987 Fire tests on building materials and structures. construction and use of buildings. Immunity standard for industrial environments BS EN 60335-2-95:2001 Safety of electrical appliances Particular requirements for drives for vertically-moving garage doors BS EN 60335-2-97:2001 Safety of electrical appliances Particular requirements for drives for rolling shutters. commercial and light-industrial environments DD 171:1987 Guide to specifying performance requirements for hinged or pivoted doors (including test methods) BS EN 61000-6-2:2001 Electromagnetic compatibility (EMC).Sash balances BS EN 61000-6-3:2001 Electromagnetic compatibility (EMC). commercial and garage doors and gates. Mechanical aspects. Method of measurement under ambient temperature conditions BS 5588 Fire precautions in the design. Generic standards. Emission standard for residential. commercial and garage doors and gates. Testing and calculation BS EN 12445:2001 Industrial. these include British and other standards and are as follows: Applicable British and other Standards BS 1245:1975 Specification for metal door frames (steel) BS 3621:2004 Thief resistant lock assemblies . Method for determination of the fire resistance of elements of construction (general principles) BS 476-22:1987 Fire tests on building materials and structures. Code of practice for wind loads BS 8220-1:2000 Guide for security of buildings against crime . Air permeability. Safety in use of power operated doors. Air permeability. Requirements BS EN 12605:2000 Industrial. Resistance to water penetration. commercial and garage doors and gates.Top hung projecting reversible hardware DD CEN/TS 13126-12:2004 Fittings for windows . Classification for weathertightness and guidance on selection and specification BS 6399-2:1997 Loading for buildings.Part 2 .• • • • • • Building Hardware Group Drive & Control Group Garage Door Group Industrial Door Group Metal Doorset Forum Repair & Service Group According to the DHF there are a number of standards which cover the products of Security Doors.Arm balancing systems DD CEN/TS 13126-11:2004 Fittings for windows . Safety in use of power operated doors. Test method BS EN 12604:2000 Industrial. Test methods BS EN 12453:2001 Industrial. and Garage Doors. Operating forces . width.Opening restrictors DD CEN/TS 13126-6:2004 BS EN 12046-2:2000 Doors . thickness and squareness BS EN 1530:2001 Door leaves . doors. doors &c .Operating forces . latches and striking plates BS EN 12210:2000 Windows and doors . Installation and use BS EN 1294:2000 Door leaves . Test method for determination of resistance under dynamic loading .Climatic Influences .Variable geometry stay hinges DD CEN/TS 13126-7:2004 Fittings for windows .Finger catches DD CEN/TS 13126-8:2004 Fittings for windows .Fittings for lift and slide systems DD CEN/TS 13126-17:2004 Fittings for windows . Burglar resistance.Air permeability Classification BS EN 12208:2000 Windows and doors .Pivot hinges DD ENV 1627:1999 Windows.Requirements and Apertures of private letter boxes and letter plates. Requirements and classification DD ENV 1628:1999 Windows. Requirements and test methods BS EN 1303:2005 Cylinders for locks BS EN 13241-1:2003 Industrial. doors. Burglar resistance.Fittings for tilt and slide systems DD CEN/TS 13126-2:2004 Fittings for windows . shutters.Resistance to windload . Test method for the determination of resistance under static loading DD ENV 1629:1999 Windows.Test method BS EN 12051:2000 Door and window bolts BS EN 12207:2000 Windows and doors .Requirements and classification BS EN 12219:2000 Doors . commercial and garage doors and gates Product standard .Bullet resistance BS EN 1527:1998 Hardware for sliding doors and folding doors BS EN 1529:2001 Door leaves .Requirements and Classification BS EN 12320:2001 Padlocks and padlock fittings BS EN 12400:2002 Windows and pedestrian doors Mechanical durability .Classification BS EN 12211:2000 Windows and doors . Pull handles.BS 8424:2004 Building hardware.Sash fasteners DD CEN/TS 13126-15:2004 Fittings for windows .Rollers DD CEN/TS 13126-16:2004 Fittings for windows . commercial and garage doors and gates.General and local flatness BS EN 1634-1:2000 Fire resistance tests for door and shutter assemblies BS EN 1634-3:2004 Fire resistance tests for door and shutter assemblies.Test method BS EN 12217:2003 Doors . doors.Tilt & turn &c hardware DD CEN/TS 13126-9:2004 Fittings for windows . Requirements and test methods BS 8621:2004 Thief resistant lock assemblies .Resistance to windload . Smoke control doors and shutters BS EN 1670:1998 Building hardware .Espagnolette bolts DD CEN/TS 13126-5:2004 Fittings for windows . shutters.Behaviour under humidity variations BS EN 12978:2003 Industrial.Height.Corrosion resistance BS EN 179:1997 Fittings for windows . Burglar resistance.Keyless egress BS EN 1125:1997 Panic exit devices operated by a horizontal bar BS EN 1154:1997 Controlled door closing devices BS EN 1155:1997 Electrically powered hold open devices for swing doors BS EN 1158:1997 Door coordinator devices garage doors and gates.Watertightness Classification BS EN 12209:2003 Mechanically operated locks.Casement fastener handles DD CEN/TS 13126-3:2004 Fittings for windows .Fittings for espagnolette bolts DD CEN/TS 13126-4:2004 Fittings for windows . shutters. Requirements and test methods BS EN 14600:2005 Doorsets and openable windows with fire-resisting and/or smoke control characteristics Requirements and classification BS EN 1522:2001 Windows.Products w/out fire/smoke resistance BS EN 13724:2002 DD CEN/TS 13126-14:2004 Fittings for windows . Safety devices for power operated doors and gates. Explosion resistance. Fire doors and shutters Shutters. Bullet resistance. Resistance to water penetration. Classification Emergency exit devices BS EN 1906:2002 Lever handles and knob furniture BS EN 1935:2002 Single axis hinges BS EN 1991-1-4:2005 Eurocode 1. Method of measurement under ambient temperature conditions Fire tests on building materials and structures. shutters and blinds. Shock tube Shutters. internal blinds. Single leaf.1:1983 Title Fire tests on building materials and structures. Methods of testing Blinds and shutters. doors and shutters. IEC 60204-1:1997 Safety of machinery. commercial and garage doors and gates. Requirements and classification. external blinds. Methods for measuring smoke penetration through doorsets and shutter assemblies. Classification BS EN 12425:2000 Industrial. Methods for determination of the fire resistance of non-loadbearing elements of construction Windows. doors and windows DD ENV 1630:1999 Windows. doors. General requirements BS EN 60335-2-103:2003 Safety of electrical appliances Particular requirements for drives for gates. commercial and garage doors and gates. doors. Misuse. Test method Fire resistance tests for door and shutter assemblies. Shock tube Windows. glossary and definitions Blinds and shutters. Actions on structures. Burglar resistance. Test method for the determination of resistance to manual burglary attempts PAS 23-1:1999 General performance requirements for door assemblies. Single and double leaf. Suitability for use of tubular and square motorizations. Terminology. Resistance to wind load. General actions. external door assemblies to dwellings PAS 24-1:1999 Enhanced security performance requirements for door assemblies. Resistance to repeated operations (mechanical endurance). hinged external door assemblies to dwellings British Standards Institute – June 2006 Analysis of the British Standard Institute’s listings have identified the following standards for Shutters/Grilles: Standard Number BS 476-31. General requirements BS EN 60335-1:2002 Specification for safety of household and similar electrical appliances. Test method. shutters. Wind actions BS EN 60204-1:1998. Test methods Shutters and blinds. Requirements and test methods Status Current BS 476-22:1987 BS EN 1523:1999 BS EN 1634-1:2000 BS EN 12194:2000 BS EN 13125:2001 BS EN 131231:2001 BS EN 131241:2001 BS EN 12216:2002 BS EN 14201:2004 BS EN 14202:2004 Current Current Current Current Current Current Current Current Current Current . doors and shutters. Electrical equipment of machines. Allocation of a class of air permeability to a product Windows. external and internal blinds. Additional thermal resistance.Classification BS EN 12424:2000 Industrial. Explosion resistance. Hard body impact. doors and shutters. Test methods Shutters and blinds power operated. doors. Commentary on test method and test data application Exterior blinds. Safety in use. Range test Shutters. Roller shutter boxes Shutters. Simplified method Fire tests. shutters and blinds. Calculation of thermal transmittance. blinds and shutters. doors. Measurement of operating force. doors. Work in Hand Current Current Current Current Current Current. doors. Bullet resistance. Thermal and visual comfort. Burglar resistance. Measurement of the transmitted force External blinds and shutters. Test method for the determination of resistance to manual burglary attempts Windows. Test method for the determination of resistance under static loading Current Current Current Current Current Current Current Current Current Current. Requirements and test methods Shutters. Determination of Current Current. Smoke control doors and shutters Thermal performance of windows. Range test Windows. Work in Hand Current. Frames Specification for safety of household and similar electrical appliances. Particular requirements for drives for rolling shutters. Test method Windows and curtain walling. Method of testing Thermal performance of windows. Requirements and classification. blinds and similar equipment. doors and shutters. doors. Test method Fire resistance tests for door and shutter assemblies. Explosion resistance. Calculation of thermal transmittance. Requirements and Current classification Thermal performance of windows. shutters. Requirements and classification Shutters and blinds.BS EN 14203:2004 BS EN 13330:2002 BS EN 1634-3:2004 BS EN 124124:2003 BS EN 13659:2004 BS EN 12833:2001 BS EN 131232:2004 BS EN 131242:2004 BS EN 14759:2005 DD ENV 1630:1999 DD ENV 1627:1999 BS EN 13527:2000 BS EN 12045:2000 BS EN 1932:2001 BS EN ISO 100772:2003 BS EN 14501:2005 DD ENV 1629:1999 DD ENV 1628:1999 BS EN 1522:1999 BS EN 124122:2003 BS EN 60335-297:2001 Blinds and shutters. doors. Work in Hand Current Current Current . doors. Burglar resistance. shutters. Performance requirements including safety Skylight and conservatory roller shutters. blinds and similar equipment Thermal performance of windows. Particular requirements. doors and shutters. Work in Hand Windows. Resistance to wind loads. Test method Windows. Determination of thermal transmittance by hot box method. Burglar resistance. and shutters. Performance characteristics and classification Windows. Acoustic insulation relative to airborne sound. Expression of performance Windows. Test method for determination of resistance under dynamic loading Windows. Burglar resistance. Explosion resistance. shutters. Test method. shutters. Resistance to snow load. Determination of thermal transmittance by hot box method. doors and shutters. Capability for use of gears with crank handle. Part 2-97: Particular requirements for drives for rolling shutters. Work in Hand Current. Resistance to load due to water accumulation. Smoke control door and shutter assemblies. awnings. Work in Hand BS EN ISO 100771:2000 BS ISO TR 59252:1997 BS EN 1933:1999 BS EN 949:1999 Current. awnings. doors and shutters. Numerical method for frames Blinds and shutters. Fire resistance tests for door and shutter assemblies. doors and shutters. Draft for Public Comment Current. Industrial commercial and garage doors and gates. Part 2. blinds and similar equipment EN ISO 10077-1. Test methods BS EN 12453. windows. Gasket and weatherstripping for doors. Offices and shops Industrial. windows. Blinds and shutters. commercial and garage doors and gates. shutters and curtain walling. Test methods ISO 3008. Extended application of test results for doorsets and shutter assemblies. Calculation of thermal transmittance. Safety in use of power operated doors. Particular requirements for drives for rolling shutters. Deflection recovery test method Building hardware. Part 2-97. Requirements prEN 15269-2. Part 2.the resistance to soft and heavy body impact for doors BS EN 12635:2002 BS EN 12978:2003 BS EN 123651:2003 BS EN 123652:2003 BS EN 123653:2003 BS EN 123654:2003 BS EN 12453:2001 BS 8220-2:1995 BS EN 12605:2000 03/115061 DC Industrial. Smoke control door and shutter assemblies.2 A1. Draft for Public Comment 03/102655 DC EN 14648. Gasket and weatherstripping for doors. windows. shutters and curtain walling. General EN 60335-2-97. commercial and garage doors and gates. Draft for Public Comment Current. Part 1. Household and similar electrical appliances. Draft for Public Comment Current. Fire door hardware. Fittings for shutters. Building hardware. Safety. Ambient and medium temperature leakage test procedure Current. Household and similar electrical appliances. Safety. Fire resistance tests. awnings. shutters and curtain walling. Particular requirements for drives for rolling shutters. Industrial commercial and garage doors and gates. Test method for fire resistance of doors and shutters Current Current Current Current Current Current Current. Fire tests. Draft for Public Comment Current. Installation and use Industrial. awnings. Draft for Public Comment 04/19991935 DC 02/104377 DC 05/30076951 DC 05/30076959 DC 05/30093062 DC 03/317805 DC 04/30113929 DC 04/30116228 DC 05/30137099 DC . Mechanical aspects. For doors and shutters. blinds and similar equipment ISO 5925-1. Thermal and visual comfort. Draft for Public Comment Current. Building hardware for fire resisting doorsets and openable windows BS EN 14500. Requirements Guide for security of buildings against crime. Thermal performance of windows. Recovery after accelerated ageing test method Industrial. Performance requirements and classification Building hardware. Requirements and test methods Building hardware. commercial and garage doors and gates. Test methods BS EN 12605. commercial and garage doors and gates. Gasket and weatherstripping for doors. Safety in use of power operated doors. Mechanical aspects. Work in Hand Current. Requirements and test Current. Draft methods for Public Comment BS EN 1634-2. windows. Draft for Public Comment Current. Draft for Public Comment Current. Gasket and weatherstripping for doors. Work in Hand Current Current. Linear compression force test methods Building hardware. Part 1. Draft for Public Comment Current. shutters and curtain walling. Steel hinged and pivoted doorsets IEC 60335-2-97 ED. Safety devices for power operated doors and gates. commercial and garage doors and gates. and garage doors and gates. commercial and garage doors and gates. Air permeability. Requirements Industrial. Work in Hand Current. Part 3. commercial and garage doors and gates. Draft for Public Comment Current. Burglar resistant construction products (not for precast concrete parts). Draft doorsets and shutter assemblies. Safety in use of power operated doors. Draft for Public Comment Current. commercial and garage doors and gates. Representation of modular sizes. Thermal transmittance. Extended application of test results for fire resistance for Current. Test method for the determination of resistance under static loading prEN 1627. Requirements and classification Steel wire and wire products for fences. Classification Industrial. Requirements for the calculation Industrial. Burglar resistant construction products (not for precast concrete parts). Burglar resistant construction products (not for precast concrete parts). Draft for Public Comment Current. Draft for Public Comment Current. commercial and garage doors and gates. Classification Industrial. Installation and use Materials and articles in contact with foodstuffs. commercial and garage doors and gates. Steel wire welded mesh fencing Construction drawings. Installation and use Industrial. Burglar resistant construction products (not for precast concrete parts). For doors and shutters. Mechanical aspects. Catering containers. General for Public requirements for fire resistance Comment EN 15269-3. Test method for the determination of resistance to manual burglary attempts prEN 1629. Types of doors Industrial. Part 1. Resistance to water Current . commercial. Draft for Public Comment Current Current Current Confirmed. Air permeability. Parts of doors Industrial. Work in Hand Industrial. and garage doors and gates. commercial. For doors and windows. Current 05/30137949 DC 06/30146718 DC 06/30146719 DC 06/30146722 DC 06/30146723 DC BS EN 102234:1998 BS EN ISO 8560:1999 BS EN 12635:2002 BS EN 631-2:1999 The British Standard Institute identifies the following standards for Garage Doors: Standard Number BS EN 124331:2000 BS EN 124332:2000 BS EN 12424:2000 BS EN 12425:2000 BS EN 12426:2000 BS EN 12427:2000 BS EN 12428:2000 BS EN 12635:2002 BS EN 12604:2000 BS EN 12453:2001 BS EN 12489:2000 Title Industrial. Terminology. Requirements Current Current Current Current Current. Test method Industrial. Dimensions of accessories and supports Current. commercial and garage doors and gates. Resistance to wind load. Timber hinged and pivoted doorsets prEN 1630. Test method for the determination of resistance under dynamic loading prEN 1628. lines and grids Industrial. Terminology. commercial and garage doors and gates. commercial and garage doors and gates. commercial and garage doors and gates.05/30137946 DC EN 15269-1. Extended application of test results for fire resistance for doorsets and shutter assemblies. Resistance to water Current penetration. Classification Status Current Current Current Industrial. Draft for Public Comment British Standards for Electric Boilers British Standards Institute – June 2006 Analysis of the British Institute website has identified the following British Standards for Electric Boilers. Products without fire resistance or smoke control characteristics Industrial. commercial and garage doors and gates. Requirements and test methods Current Current Current Current. Requirements IEC 60335-2-95-A1 ED. Commercial electric water boilers and liquid heaters Specification for automatic electrical controls for household and similar use. Industrial commercial and garage doors and gates. commercial and garage doors and gates. commercial and garage doors and gates. Automatic electrical water level sensing controls of the float or electrode-sensor type used in boiler applications. Safety. Standard Number BS 1894:1992 BS EN 60335-263:1993 BS EN 60730-215:1996. Safety in use of power operated doors. Test methods Household and similar electrical appliances. Operational noise. Requirements and test methods Industrial. Test methods BS EN 12445. Industrial commercial and garage doors and gates. Safety in use of power operated doors. Draft for Public Comment Current. Industrial commercial and garage doors and gates. Draft for Public Comment prEN 12652. Particular requirements. Industrial. IEC 60730-2-15:1994 Title Specification for design and manufacture of electric boilers of welded construction Specification for safety of household and similar electrical appliances. Revised Current. Partially Replaced Current. Test methods Specification for safety of household and similar electrical appliances. Test method BS EN 12444:2001 BS EN 12978:2003 BS EN 132411:2003 BS EN 12605:2000 BS EN 60335-295:2001 BS EN 12445:2001 BS EN 60335-295:2004 96/108073 DC 96/108703 DC 05/30076926 DC 05/30076951 DC 05/30076956 DC 05/30076959 DC 03/317783 DC Industrial. Safety of household and similar electrical appliances. Industrial.2. commercial and garage doors and gates.15: Automatic electrical water level sensing controls controls of the flaot or electrode-sensor type used in boiler applications Status Current. Industrial commercial and garage doors and gates. commercial and garage doors and gates. Safety devices for power operated doors and gates. Resistance to wind load. Work in Hand Current Current. Particular requirements for drives for vertically moving garage doors for residential use Industrial. Sound Current. Section 2. Particular requirements for drivers for vertically moving garage doors for residential use prEN 12624. Draft for reduction. Mechanical aspects. commercial and garage doors and gates. Particular requirements for drives for vertically moving garage doors for residential use Current. Draft for Public Comment Current. Test methods BS EN 12453.penetration. Superseded Current. Testing and calculation Industrial. Requirements BS EN 12605. Particular requirements. Requirements and classification Public Comment EN 12604. Work in Hand . Work in Hand Current. Draft for Public Comment Current. Safety in use of power operated doors. Product standard. Mechanical aspects. Mechanical aspects. commercial and garage doors and gates. Draft for Public Comment Current. Particular requirements. including mechanical requirements Specification for safety of household and similar electrical appliances. Work in Hand Current Specification for automatic electrical controls for household and similar Current. Particular requirements for Appliances for heating liquids Specification for underfeed stokers Recommendations for treatment of water for steam boilers and water heaters Water-tube boilers and auxiliary installations. Specification for combination boilers IEC 60730-2-15 ED. Work in use. Particular requirements forautomatic electrical water and air flow sensing controls. Work in Hand Current. Measurements Current. Particular requirements. Requirements for firing systems for liquid and gaseous fuels for the boiler Specification for safety of household and similar electrical appliances. Requirements for equipment for the boiler Code of practice for low temperature hot water heating systems of output greater than 45 kW. Heating boilers. commissioning and maintenance Specification for safety of household and similar electrical appliances. including mechanical requirements. Appliances for heating liquids. Revised Current Current Current Current Confirmed. EN 60335-2-46:1989 BS EN 14597:2005 BS ISO 1461711:2002 BS EN 129527:2002 BS 6880-2:1988 BS EN 60730-218:1999. Specification for safety of household and similar electrical appliances. Part 2-15. Obsolescent Current. Devices for heat transfer and heat engines Water-tube boilers and auxiliary installations. Draft for Public Comment British Standards for Metal Roofing . Automatic controls for household and similar use. Particular requirements for automatic Hand electrical water and air flow sensing controls. Particular requirements. Partially Replaced Current. Particular requirements for automatic electrical water level sensing controls of the float or electrode-sensor type used in boiler applications BS EN 60730-2-15/prA11. Commercial electric steam cookers Temperature control devices and temperature limiters for heat generating systems Graphical symbols for diagrams. Electrical power consumption for heat generators. Draft for Public Comment BS EN 60335-275:2004 BS 5258-15:1990 03/117957 DC 04/30115376 DC Current. Particular requirements for commercial dispensing appliances and vending machines Safety of domestic gas appliances. Particular requirements for appliances for heating liquids Specification for electrical safety and performance of gas fired space heating appliances with inputs 60 kW to 2 MW Code of practice for low temperature hot water heating systems of output greater than 45 kW. IEC 60335-2-15:1995 BS 749:1969 BS 2486:1997 BS EN 129528:2002 BS EN 60335-215:2002 BS 5986:1980 BS 68803:1988 BS 3456202.46:1990. Particular requirements for automatic electrical water level sensing controls of the float or electrode-sensor type used in boiler applications EN 15456. Installation. Part 2-15. Selection of equipment Current. Automatic electrical controls for household and similar use. IEC 60730-2-18:1997 Specification for welded steel boilers for central heating and indirect hot water supply (rated output 44 kW to 3 MW) Specification for safety of household and similar electrical appliances. Particular requirements. Particular requirements. Draft for Public Comment 06/30145467 DC Current.2.BS 855:1990 BS EN 60335-215:1996. Current Current Current Current Current Current. System boundaries. Profiled fibre cement . BS EN 12152 :2002 Curtain Walling . Satjam may be required to meet the British Standards set for the materials used for the tile for example regulations on the base metal. aluminium or stainless steel sheet. Specification for fully supported products of stainless . corrugated and troughed Fibre-cement profiled sheets and fittings for roofing. Steel Roofing products from metal sheet. General requirements and test methods Light transmitting profiled plastic sheeting for single skin roofing. The Standards shown on the RoofConsult website are as follows: British Standards .Metal Roofing BS EN 501 :1994 BS EN 502 :2000 Roofing products from metal sheet.Sheeting & Cladding CP 143 -1:1958 BS EN 494 :1994 BS EN 506 :2000 BS EN 508 -1:2000 BS EN 508 -2:2000 BS EN 508 -3:2000 el BS EN 1013 1:1998 L BS EN 1013 2:1999 BS EN 1013 3:1998 BS EN 1013 4:2000 BS EN 1013 5:2000 BS 5427 -1:1996 BS 8219 :2001 Code of practice for sheet roof and wall coverings. test methods and performance of polymethylmethacrylate (PMMA) sheets Code of practice for the use of profiled sheet for roof and wall cladding on buildings Installation of sheet roof and wall coverings . Specification for self-supporting products of steel. test methods and performance of polycarbonate (PC) sheets Light transmitting profiled plastic sheeting for single skin roofing. aluminium or stainless steel sheet. The only British Standard in place which relates to this type of product is a code of practice for cladding buildings – BS 5427.Air permeability . aluminium or stainless steel sheet. listed on the RoofConsult website. Product specification and test methods Roofing products from metal sheet. Aluminium Roofing products from metal sheet. Design In order to trade in the UK. Specific requirements. The British Standards. Specification for self-supporting products of copper or zinc sheet Roofing products from metal sheet.Performance requirements and classifications British Standards . Satjam may be required to meet British Standards with regards to the components of their tile product. Specific requirements and test methods for sheets of polyvinyl chloride (PVC) Light transmitting profiled plastic sheeting for single skin roofing. Specific requirements and test methods for sheets of glass fibre reinforced polyester resin (GRP) Light transmitting profiled plastic sheeting for single skin roofing. RoofConsult – May 2006 RoofConsult are an advisory service involved in the UK roofing and cladding industry. Specification for self-supporting products of steel. Specific requirements. Aluminium.Code of Practice. the coatings etc. Specification for self-supporting products of steel. Specifications for fully supported roofing products of zinc sheet Roofing products from metal sheet.Metal Cladding & Roofing Manufacturers Association According to the Metal Cladding & Roofing Manufacturers Association there are currently no British Standards covering the stone coated metal tile product which Satjam manufacture. Stainless ste Light transmitting profiled plastic sheeting for single skin roofing. That is. BS 5427-1:1996 Code of practice for the use of profiled sheet for roof and wall cladding on buildings. which relate most closely to the products produced by Satjam are those covering Sheeting and Cladding and those covering Metal Roofing. Specification for fully supported roofing products of aluminium Zinc and zinc alloys. George recommended that the Czech companies approach a testing board such as the BBA to have their product tested in order to receive certification for selling in the UK. shows there are no specific British or European standards for steel roof tiles. Mr. George from RoofConsult has advised that as far as his records. Specification for fully supported roofing products of steel sheet Roofing products from metal sheet. Alternatively he suggested they apply for an E-Tag in order to receive CE marking for the product. Specification for fully supported roofing products of copper sheet Roofing products from metal sheet.steel sheet BS EN 504 :2000 BS EN 505 :2000 BS EN 507 :2000 BS EN 988 :1997 BS 6915 :2001 BS EN 14782:2006 Roofing products from metal sheet. Specification for rolled flat products for building Design and Construction of fully supported lead sheet roof and wall coverings. Code of practice Self-supporting metal sheet for roofing. British Standards Institute – June 2006 Analysis of the British Standards Institute has identified the following British Standards for Satjam’s type of roofing products: British Standards for Roof Tiles: . Product specification and requirements David George (RoofConsult’s Standards & Flat Roofing Materials Expert): Mr. and those of a colleague of his at BSI. external cladding and internal lining. Impermeability test Concrete roofing tiles and fittings for roof covering and wall cladding. Test method for mechanical fasteners BS EN 539-2. Specification for fully supported products of stainless steel sheet Roofing products from metal sheet. Aluminium Roofing products from metal sheet. Test for frost resistance EN 490 AMD 1. Specification for self-supporting products of steel. Part 2. Specification for self-supporting products of steel. Work in Hand Confirmed. Work in Hand Current. Concrete and tile making machines Clay roofing tiles and fittings. Metric units Structural use of steelwork in building. Safety. Roof system test method Terrazzo tiles. Product specifications Workmanship on building sites. aluminium or stainless steel sheet. Clay roofing tiles for discontinuous laying. Determination of physical characteristics. Determination of physical characteristics. Determination of geometric characteristics Code of practice for slating and tiling (including shingles) Determination of the uplift resistance of clay or concrete tiles for roofing. Stainless steel Roofing products from metal sheet. Proposed for Confirmation Current Current . Flexural strength test Clay roofing tiles for discontinuous laying. Product specifications Status Current Current Current Current Current. aluminium or stainless steel sheet. Terrazzo tiles for external use Determination of the uplift resistance of installed clay and concrete interlocking tiles for roofing. Test for frost resistance Concrete roofing tiles and fittings for roof covering and wall cladding. Determination of physical characteristics. Concrete roofing tiles and fittings for roof covering and wall cladding. Code of practice for design of light gauge profiled steel sheeting Self-supporting metal sheet for roofing. Product specification and requirements Status Current Current Current Current Current Current Current. Code of practice for sheet roof and wall coverings. Draft for Public Comment Current. Product definitions and specifications Clay roofing tiles for discontinuous laying. Specification for self-supporting products of steel. Test methods Clay roofing tiles for discontinuous laying. roof and wall coverings Roofing products from metal sheet. Specification for fully supported roofing products of steel sheet Code of practice for sheet roof and wall coverings.Standard Number BS EN 126294:2001 BS EN 1304:2005 BS EN 539-1:2005 BS EN 491:2004 BS EN 539-2:1998 BS EN 490:2004 BS 8000-6:1990 BS EN 538:1994 BS EN 1024:1997 BS 5534:2003 BS EN 14437:2004 BS EN 137482:2004 DD CEN/TS 15087:2005 04/30099864 DC Title Machines for the manufacture of constructional products from concrete and calciumsilicate. Current Current Current Current Current Current Current Current. Galvanized corrugated steel. Code of practice for slating and tiling of roofs and claddings Clay roofing tiles for discontinuous laying. external cladding and internall ining. Steel Roofing products from metal sheet. aluminium or stainless steel sheet. Fixings for sheet. Draft for Public Comment 05/30139071 DC British Standards for Steel Roof Products: Standard Number BS 1494-1:1964 BS EN 5081:2000 BS EN 5082:2000 BS EN 5083:2000 BS EN 502:2000 BS EN 505:2000 CP 143-10:1973 BS 5950-6:1995 BS EN 14782:2006 Title Specification for fixing accessories for building purposes. Specification for self-supporting products of steel. Flexural strength test Status Current . Products for building exterior applications EN 14783. Associated plant and equipment. Aluminium Roofing products from metal sheet.BS 5950-7:1992 BS 5427-1:1996 BS 5950-9:1994 DD ENV 101692:1999 03/115371 DC Structural use of steelwork in building. Metric units Glossary of building and civil engineering terms. Specifications for fully supported roofing products of zinc sheet Roofing products from metal sheet. Fully supported metal sheet and strip for roof coverings and wall finishes Status Current Current Current Current Current Current Current Current Current.5. Product specification and requirements Structural use of steelwork in building. Code of practice for stressed skin design Continuously organic coated (coil coated) steel flat products. Factory made products. Proposed for Confirmation. Operations. Roofing products from metal sheet. Proposed for Confirmation Current. Self-supporting double skin metal faced insulating sandwich panels. Specification for materials and workmanship: cold formed sections Code of practice for the use of profiled sheet for roof and wall cladding on buildings. Jointing prEN 503. Design Structural use of steelwork in building. Specification for materials and workmanship: cold formed sections Roofing products from metal sheet. Specification for self-supporting products of steel. Specification for fully supported products of stainless steel sheet Code of practice for sheet roof and wall coverings. General and miscellaneous. Steel Roofing products from metal sheet. Fully supported metal sheet and strip for roof coverings and wall finishes Current. Specification for fully supported roofing products of steel sheet Roofing products from metal sheet. Obsolescent Current Current Current. Specification for fully supported roofing products of aluminium sheet Roofing products from metal sheet. aluminium or stainless steel sheet. Draft for Public Comment Current. aluminium or stainless steel sheet. Specification for fully supported roofing products of lead sheet prEN 14509.2:1987 96/104019 DC 02/105004 DC 03/115371 DC Title Roofing products from metal sheet. Work in Hand Current. Obsolescent Current Current Current Current. Draft for Public Comment Current. Stainless steel Roofing products from metal sheet. Galvanized corrugated steel. external cladding and internall ining. Specification for self-supporting products of copper or zinc sheet Roofing products from metal sheet. Specification for fully supported roofing products of copper sheet Self-supporting metal sheet for roofing. Draft for Public Comment British Standards for Clay/Stone Roofing Products: Standard Number BS EN 538:1994 Title Clay roofing tiles for discontinuous laying. aluminium or stainless steel sheet. Specification for self-supporting products of steel. Specification EN 14783. Draft for Public Comment British Standards for Metal Roof Products: Standard Number BS EN 501:1994 BS EN 5081:2000 BS EN 5082:2000 BS EN 5083:2000 BS EN 507:2000 BS EN 505:2000 BS EN 504:2000 BS EN 14782:2006 BS 5950-7:1992 BS EN 506:2000 BS EN 502:2000 CP 143-10:1973 BS 61001. Code of practice for sheet roof and wall coverings. fabrication and erection. Code of practice for selection and use of construction materials Eurocode 3. Standard Number BS 449-2:1969 BS 5950-3. Design of steel structures. Impermeability test Determination of the uplift resistance of clay or concrete tiles for roofing. Design in composite construction. Specification for materials. Determination of physical characteristics. Draft for Public Comment Current Current British Standards for Prefabricated/Modular Buildings and Structural Steel Buildings British Standards Institute – June 2006 Analysis of the British Institute website has identified the following British Standards for Structural Steel Buildings. Code of practice for stressed skin design Execution of steel structures. Obsolescent Current Current Current Current Current Current Current . Specification for materials and workmanship: cold formed sections Structural use of steelwork in building set Structural use of steelwork in building. Methods of test Current Current Current Current Current Current.BS EN 1024:1997 BS EN 1304:2005 BS EN 5391:2005 BS EN 14437:2004 DD CEN/TS 15087:2005 BS EN 5392:1998 04/30099864 DC BS EN 123261:2004 BS EN 123262:2000 Clay roofing tiles for discontinuous laying. General rules. Work in Hand Current.1:1990 BS 5950-4:1994 BS 5950-9:1994 DD ENV 1090-1:1998 BS 5950-7:1992 KIT 14 BS 5950-2:2001 BS 5950-6:1995 BS EN 1993-1-1:2005 BS 5502-21:1990 DD ENV 1993-13:2001 BS 5950-8:2003 Title Specification for the use of structural steel in building. Product definitions and specifications Clay roofing tiles for discontinuous laying. Clay roofing tiles for discontinuous laying. Part 2. Code of practice for design of simple and continuous composite beams Structural use of steelwork in building. Test for frost resistance BS EN 539-2. General rules and rules for buildings (together with United Kingdom national application document) Structural use of steelwork in building. Test for frost resistance Slate and stone products for discontinuous roofing and cladding. Rolled and welded sections Structural use of steelwork in building. General rules and rules for buildings Buildings and structures for agriculture. Product specification Slate and stone products for discontinuous roofing and cladding. Code of practice for design of composite slabs with profiled steel sheeting Structural use of steelwork in building. Test method for mechanical fasteners Clay roofing tiles for discontinuous laying. Design of steel structures. Roof system test method Determination of the uplift resistance of installed clay and concrete interlocking tiles for roofing. Code of practice for design of light gauge profiled steel sheeting Eurocode 3. Determination of physical characteristics. Metric units Structural use of steelwork in building. Determination of geometric characteristics Clay roofing tiles and fittings. Determination of physical characteristics. Supplementary rules for cold formed thin gauge members and sheeting Structural use of steelwork in building. Code of practice for fire resistant design Status Current Current Current Current Current Current. Draft for Public Comment . Material toughness and throughthickness properties Eurocode 3. Structural fire design Eurocode 3. Work in Hand Current Current Current Current. General rules. Code of practice for sheet roof and wall coverings. Fatigue Eurocode 4. Rolled and welded sections Test methods for determining the contribution to the fire resistance of structural members. Applied protection to concrete filled hollow steel columns Code of practice for sheet roof and wall coverings. Steels for seismic improved resistance for building EN 10340. Applied protection to steel members Test methods for determining the contribution to the fire resistance of structural members.BS EN 1993-1-2:2005 BS EN 1993-110:2005 BS EN 1993-1-8:2005 BS EN 1993-1-9:2005 BS EN 1994-1-2:2005 BS 5950-1:2000 DD ENV 133812:2002 BS 5975:1996 BS EN 1994-1-1:2004 BS 6180:1999 BS 8414-2:2005 Eurocode 3. Design of steel structures. Design of steel structures. Proposed for Confirmation Current. General rules and rules for buildings Barriers in and about buildings. Design of steel structures. Galvanized corrugated steel. Work in Hand Current Current Current Current Current BS 5950-5:1998 DD ENV 133814:2002 DD ENV 133815:2002 DD ENV 133816:2002 CP 143-10:1973 05/30092093 DC 04/30123271 DC Current. Metric units ISO 24314. Steel castings for structural uses Current Current Current Current Current Current. Draft for Public Comment Current. Code of practice for design of cold formed thin gauge sections Test methods for determining the contribution to the fire resistance of structural members. Design of steel structures. Design of composite steel and concrete structures. General rules. Code of practice for design. Design of joints Eurocode 3. Vertical protective membranes Code of practice for falsework Eurocode 4. Code of practice Fire performance of external cladding systems. Structural steels. Test method for nonloadbearing external cladding systems fixed to and supported by a structural steel frame Structural use of steelwork in building. Design of composite steel and concrete structures. Applied protection to concrete/profiled sheet composite members Test methods for determining the contribution to the fire resistance of structural members. Structural fire design Structural use of steelwork in building.