Wall fansHigh air performance and low energy consumption The frame has an aerodynamic shape and is made of high-quality sheet steel.Wall fans – efficient and durable The Big Dutchman wall fans are very versatile with a high performance. They are also corrosion-proof and made for a long service life. Shutters This shutter is a self-actuated closing flap made of PVC. Thanks to the large variety they can be ideally adapted to any type of barn. 4 quick and easy assembly. 4 long service life. we also offer V-belt driven fans. Let our experts advise you which solution best fits your requirements. 4 high corrosion resistance. 4 low noise level. the latter being more pressure-resistant and quieter. 4 high air capacity at a low energy consumption. Standard fan (FC) Sickle-shaped fan (FE) Advantages 4 excellent adjustability. low energy consumption and low maintenance costs. Dimensions and installation details Ø Impeller A B C D E F (in cm) (in mm) 35 435 485 375 86 75 89 40 490 540 420 91 88 102 45 535 575 480 75 96 123 50 615 655 528 77 104 141 56 675 725 589 60 119 138 63 750 805 664 64 130 154 71 810 850 763 44 150 202 80 910 970 869 34 193 252 91 1010 1070 977 48 190 197 . If the fan is at a standstill. Axial fans with frame Excellent adjustability Our axial fans with frame are ideally suited for incorporation into walls. Our product range includes standard fans (FC) as well as sickle-shaped fans (FE). Wire mesh guard A wire mesh guard is required if the fan is installed in an accessible location. In addition to steelframe axial fans. the shutter is closed. The blades are made of moulded aluminium diecasting and therefore have an exceptionally high degree of efficiency. The V-belt is pretensioned.AirMaster Advantages High air performance 4 optimised aerodynamics at the air admission and air exit sides for a high air flow rate. use of exhaust air treatment systems). The motor is completely closed. 4 easy to assemble and easy to install in the building. the shutters close. V-belt gearing The V-belt pulley is made of aluminium and is manufactured as one piece together with the blade hub by diecasting. a separate cooling fan is not necessary. approved for UL/CSA). Important components Casing The fan casing consists of galvanized sheet steel. The 5-blade AirMaster is often installed in barns with a high back pressure (cage houses with tunnel ventilation. 4 the shutters open by the air flow pressure and stay open thanks to balancing weights –> minimal air resistance. Shutters The shutters are opened by the air flow and then kept open by means of a balancing weight. Blade and blade hub The vane has 3 or 5 specially shaped blades made of glass-fibre reinforced plastic. The blade hub is made of aluminium. 4 stable. robust and simple design. Electric motors We use high-quality motors with a large voltage range (motor protection IP 55. the inside construction is made of high-quality polypropylene for a high corrosion resistance. 4 low noise level. 4 specially-formed blades ensure optimum operation thus reducing energy costs. Air guide-rails on every blade ensure a large air capacity combined with a low resistance and thus low energy consumption. electric motor without cooling fan with protective cover –> well-protected against dust specially-formed blades made of glass-fibre reinforced plastic with air guide-rails for optimum air performance all 4 corners are equipped with plastic covers –> no dirt corners –> good hygiene shutters are opened by the air flow –> a centrifugal system is not necessary central V-belt pulley made of aluminium with pretensioned V-belt –> retensioning not necessary diagonal braces for better stability fan with 3 or 5 blades extremely stable connection between hub and blade –> copes well with high loads . This means there is no danger of dust entering the motor or overheating of the motor. When the fan stops. further tensioning is therefore not necessary. 5 PS E13 60-25-4505 V130-5 1.5 PS-R 60-25-4060 NC NC FC NC FC FC FC NC NC NC FC FC 0 Pa Air capacity in m3/h 20 Pa 30 Pa 40 Pa 60 Pa 80 Pa Consumption Ampere Spec.3 36. The air performance is reduced by approx.9 29. at a distance of approx. output Watt/1000m3/h 27. As opposed to fans without CE mark these fans possess a protective grating (in front of the shutters at an installation height below 2.5 PS E13 60-25-4501 V130-3 1. Speed control V130-3 1. on request available with other voltages and frequencies Weight: AirMaster without cone: 80 kg.2 41800 38800 37 200 35 600 32 300 27 100 3. 130 = diameter of impeller.2 44700 40500 38400 36 000 29 300 3.5 33.8 34.0 43100 40000 38700 37 000 33 900 28 300 3.4 Noise level dB(A)* 72 74 74 74 74 74 74 72 74 74 74 74 40400 36100 33100 29 900 2.5 PS-R 60-25-4140 VC130-3 1.5 PS-R 60-25-4141 V130-5 1. AirMaster with cone: 99 kg * Noise level measured at the outlet side 45° lateral. Light trap Big Dutchman offers two light traps.5 PS E13 60-25-4503 V130-5 1.3 34. The previous model reduces the amount of light passing through the fan to a minimum and is thus especially suited for rearing and breeding houses.8 24.70 m).6 33. reducing the air performance by only approx. 10 %.0 39600 36500 35 000 33 400 29 800 25 600 3. The new light trap PerforMacs is ideally suited for broiler and laying houses. It has been optimised aerodynamically. 3 = 3-blade.1 38700 35600 34 100 32 500 28 800 24 500 3. Technical specifications of the series AirMaster V130 / VC130 Type Code No. 12 %. 2 m.3 49000 45200 43 100 40 700 35 900 3. 50 Hz.3 33. all types also available unassembled 1380 .6 29.0 PS E13 60-25-4565 VC130-3 1.0 44 700 40500 38 400 36 000 29 300 3.Dimensions: V130 VC130 522 275 95 152 85 85 1380 133 275 1275 782 Ø1600 1380 If used in the EU.6 34. VC = fan with cone. R = standard motor (only for use outside of the EU) E13 = complies with the directive 2009/125/EC (ErP Directive) starting 2013 NC = non-controllable FC = frequency-controllable Connection values: 400 V. 5 = 5-blade.0 39600 36500 35000 33 400 29 800 25 600 3. the fans must carry the CE mark of conformity.0 47700 43800 41 600 39 200 34 300 21 800 3.7 36.5 PS E13 60-25-4563 VC130-3 1.1 V = fan without cone.0 43700 39700 37500 34 800 28 600 19 200 3.0 44500 40400 37 800 35 400 2. The segments of both light traps are made of plastic which makes them extremely durable and easy to clean.5 PS E13 60-25-4561 VC130-5 1.0 PS E13 60-25-4509 V130-3 1.5 PS-R 60-25-4020 VC130-5 1.5 PS E13 60-25-4507 V130-3 1. They are also characterized by a low power consumption. 1380 AirMaster with cone Cone fans (VC130) are mainly used in barns with especially large air-flow performance requirements. On request the fans are also available frequency-controlled and/or with different supply voltage and/or 60 Hz.8 20900 / 58.4 8 870 / 43.7 12 380 / 40.1 7480 / 47.6 15550 / 52.6 23 000 / 50.6 6120 / 58.1 0.9 22 900 / 48.0 14600 / 58.6 6.4 18600 / 50.0 16150 / 50.3 4.9 7 800 / 58.2 kg/m3.6 21410 / 41.4 2.3 6900 / 73.3 0.8 2.6 21050 / 58.95 2.3 10550 / 53.7 6 470 / 45. The motors are fabricated according to the IP 54 (dust-proof and water-proof) protection system.9 4 510 / 52.7 12 300 / 42.3 20 Pa 3180 / 50.9 3. 60-47-9135 60-47-9140 60-47-9145 60-47-9150 60-47-9156 60-47-9163 60-47-9171 60-47-9180 60-47-9191 Power consumption (Watt) 157 243 341 450 388 545 785 1. output (W/1000 m3/h) Type / Negative pressure FC035-4EQ FC040-4EQ FC045-4EQ FC050-4EQ FC056-6EQ FC063-6EQ FC071-6EQ FC080-6EQ FE091-6EQ 0 Pa 10 Pa 3 320 / 47.0 3640 / 67.6 7860 / 51. 50 Hz FC045-4DQ FC050-4DQ FC056-6DQ FC063-6DQ FC071-6DQ FC080-6DQ FE091-6DQ Code No.0 8210 / 49.2 20450 / 61.0 15000 / 55. Three-phase power supply 400 V.3 5780 / 64.0 11400 / 47.1 6.4 Noise level (dB(A)) 53 54 48 53 55 55 57 The noise level was measured free-blowing at a 45° angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase).3 1.0 4.3 17600 / 54.2 Noise level (dB(A)) 46 51 53 54 48 53 55 55 57 The noise level was measured free-blowing at a 45° angle from the centre of the fan at a distance of 7 m (at 0 Pa pressure increase). 6 = 6-pole 35 = dia impeller (cm) E = 1-phase (1~ 230 V) D = 3-phase (3~ 400 V) Q = wall installation Technical specifications: 1 ~ 230 V.3 2.3 16 450 / 47.0 7660 / 61.8 8 530 / 38.4 1. All mentioned fans 1 ~ 230 V and 3 ~ 400 V can be controlled electronically or by a transformer.2 kg/m3.4 16 600 / 48.8 14000 / 61.6 7850 / 44. Air capacity Single-phase power supply 230 V. 50 Hz: capacity (m3/h) / spec. output (W/1000 m3/h) Type / Negative pressure FC045-4DQ FC050-4DQ FC056-6DQ FC063-6DQ FC071-6DQ FC080-6DQ FE091-6DQ 0 Pa 10 Pa 6 290 / 48.2 7400 / 64.9 40 Pa 2910 / 57.8 1.9 7250 / 67.3 15 950 / 50.6 8 330 / 51.74 1.5 18410 / 49.8 3950 / 61.9 1.3 12000 / 43.0 21200 / 44.7 20100 / 46.75 1.5 21920 / 53.2 6 350 / 53.3 10000 / 56.0 11 750 / 45.0 8 120 / 53.3 14800 / 57.2 5560 / 68.3 7630 / 62.5 15600 / 53.7 10760 / 51.6 Motor protection switch (Ampere) 1.5 12 750 / 38.0 3 460 / 45.7 4.3 22 400 / 34.7 8 000 / 55.3 1.4 3260 / 75.0 6910 / 60.7 The capacity was measured without wire mesh guard and at an air density of 1.8 50 Pa 2810 / 59.4 4 790 / 48.4 20 Pa 6130 / 50.7 21700 / 56.4 22 200 / 41.9 4240 / 56.5 5950 / 61.1 8 850 / 36.4 23 130 / 38. .7 11000 / 50.1 2.5 11650 / 45. 60-47-9645 60-47-9650 60-47-9656 60-47-9663 60-47-9671 60-47-9680 60-47-9691 Power consumption (Watt) 295 432 323 484 780 1120 939 Nominal current (Ampere) 0.1 8 560 / 46.8 1.0 40 Pa 5820 / 55.7 7430 / 55.7 50 Pa 5650 / 58.4 22 300 / 53.0 17 000 / 45.7 15300 / 54.Technical specifications of axial fans with frame Description details FC035-4EQ FE091-6DQ FC = standard fan FE = sickle-shaped fan 4 = 4-pole.5 1.7 1. 50 Hz FC035-4EQ FC040-4EQ FC045-4EQ FC050-4EQ FC056-6EQ FC063-6EQ FC071-6EQ FC080-6EQ FE091-6EQ Code No.1 21400 / 56.4 7970 / 56.3 8200 / 41. 50 Hz: capacity (m3/h) / spec.1 30 Pa 3050 / 53.2 3.95 Motor protection switch (Ampere) 0.2 22 440 / 51.0 1.3 7060 / 50.7 2.6 20340 / 61.1 6 260 / 55.1 7470 / 64.9 19450 / 46.9 2.2 19850 / 64.7 5. Technical specifications: 3 ~ 400 V.9 23 370 / 36.4 30 Pa 5950 / 52.5 The capacity was measured without wire mesh guard and at an air density of 1.4 20450 / 44.3 11190 / 48.9 7800 / 59.160 895 Nominal current (Ampere) 0. +49(0) 4447 801-0 · Fax -237 big@bigdutchman.. Tel.com.com · www.bigdutchman.com www. Tel.com Brazil: Big Dutchman (Brasil) Ltda. Depen ding on the climate zone.ru · www.bigdutchman. AirMaster fans in the gable can be switched on for additional ventilation on hot summer days.ru Asia/Pacific: BD Agriculture (Malaysia) Sdn. Longitudinal ventilation is normally accomplished by means of AirMaster fans as these have a higher air capacity. +55 16 2108 5300 · bigdutchmanbrasil@ bigdutchman. +60 3 33 61 5555 · bdasia@bigdutchman. different ventilation concepts are possible. CombiTunnel ventilation is best installed in climate zones with large temperature fluctuations – summer/winter or day/night temperatures.bigdutchman. Cross ventilation Side ventilation Longitudinal ventilation Tunnel ventilation CombiTunnel ventilation Decentralized exhaust air extraction with additional gable ventilation Technical details subject to change.com.br Russia: OOO “Big Dutchman” Tel.bigdutchman. en 6/2013 Germany: Big Dutchman International GmbH Big Dutchman Pig Equipment GmbH Postfach 1163 · 49360 Vechta Tel. +1 616 392 5981 · [email protected] BD Agriculture (Thailand) Ltd. This is a so-called displacement ventilation at minimum energy consumption. Inc.de USA: Big Dutchman. Ltd.br www.bigdutchman. In case of tunnel ventilation they pull the air through the barn in longitudinal direction at a high air speed.Areas of application Our wall fans are very versatile. 762 China: Big Dutchman (Tianjin) Livestock Equipment Co. Side and cross ventilation are often established by means of axial fans. +7 495 2295 171 · [email protected] · www. In the case of decentralized exhaust air extraction via chimneys in the roof.co.cn . They pull the air across the barn. Tel.th Abb. +86 10 6476 1888 · bdcnsales@ bigdutchman.bigdutchman. +66 2 349 6531 · bdt@bigdutchman. Bhd. Tel.com www.de · www. Tel.bigdutchmanusa.