ASTM_D664

March 30, 2018 | Author: HalanEn | Category: Titration, Personal Computers, Databases, Oracle Database, Sodium Hydroxide


Comments



Description

ISO 9001for quality assurance H i g h P e r f o m a n c e : AT- 5 1 0 L o w C o s t : AT- 5 0 0 N - 1 , AT- 5 0 0 N - 2 CE marked for product safety GLP/GMP conformed ISO 14001 environmental management systems M u l t i - c h a n n e l S o f t w a r e : AT- W i n F D A 2 1 C F R P a r t 1 1 C o m p l i a n t S o f t w a r e : AT- W i n / E R KYOTO ELECTRONICS KEM Product Line A wide selection of KEM Automatic Potentiometric Titrators models is available from process or quality control in production to research and development works in laboratory. High Perfomance : AT-510 CHA-500 Multiple Sample Changer as an option. Low Cost : AT-500N-1, AT-500N-2 1 KEM Product Line Multi-Channel Software : AT-Win FDA 21 CFR Part 11 Compliant Software : AT-Win/ER Security Integrity Audit Trail Electronic Signatures 2 . 5mL.Features of AT Product Line AT-510 AT-500N-1 . 20mL. CMT-510 TET-510 STD-510 PTA-510 POT-510 SOFT-CAPE Yes Yes Sample changer 3 No Screen display on PC Screen display on PC HD and other devices HD and other devices Depending on a titrator - - . POT-510 PTA-510. 10mL. 2 AT-Win AT-Win/ER Main unit Main unit PC PC Language English / Japanese English English / Japanese English / Japanese Data entry Key-in Key-in Keyboard and Mouse Keyboard and Mouse 1 channel 1 channel 4 channels 4 channels 126 x 70mm LCD with backlight 16 digits x 2 lines LCD with backlight Real time titration curve Yes No Yes (Multi-line) Yes (Multi-line) GLP/GMP conformed Yes Yes Yes Yes 10 APB-510 to AT-510 (one built-in) 10 APB-510 to AT-510 (one built-in) 40 APB-510 to 4 AT-510 (4 built-in) 40 APB-510 to 4 AT-510 (4 built-in) - - Controlling unit Multitasking Display Connectable number of APB-510 10 (one built-in) Burette capacity 50mL. 1mL Data storage media PC card No Yes Yes - - FDA 21 CFR Part 11 Need AT-Win/ER Need AT-Win/ER No Yes Electronic balance Yes Yes Yes Yes Preamplifier STD-510. GLP/GMP fully conforming 5. Increase in the types of endpoint detection 3. precipitation. analytical works and R&D activities are demanded and conducted. Anti-diffusion structure on titration nozzle of burette 4. When the multiple sample changer CHA-500 is connected. This new model can perform potentiometric titration including acid-base. chelatometric and non-aqueous titrations. it can also perform photometric. thus applicable to many fields where quality and inspection control. Oversized LCD provides clearer readout of information such as Titration Curve and Messages 2. Features 1. Printing on A4/Letter size paper as an option 4 . With optional peripherals. polarization and surfactant titrations. redox.AT-510 Automatic Potentiometric Titrator The AT-510 Automatic potentiometric titrator is a new version of AT series offering better operational maneuverability and compactness in size while inheriting KEM’s many years’ advanced proven technology. KF (volumetric) moisture titration unit as an option 7. Data storing / recalling with PC card 6. COD titration unit as an option 8. it can automate measurements of a number of samples unattended and save both time and man-power with reliable results and simpler operations. Interface 1. Changer File 6. CE-marking level of safety and noise immunity 8. Functions include: 0. 6.AT-500N Automatic Potentiometric Titrator Features 1. Method Copy 3.Regist Operator 3. Three (3) interface ports : Balance.Set Check 7.Buret Check 9. 4. Anti-diffusion titration nozzle tip 4.LCD Contrast 5. etc.Sample File 3.Lock 7.Common Blank 12.Table 13. Data File 4. PC and Printer Configuration of Function Keys Example of printout APB Enter Purge mode of burette or dose volume Up key Deliver Titrant Down key Fill Titrant and exchange burette unit Purge key Purge Titrant Print Print key Print out Stirrer Stirrer key Turn on/off stirrer and select stirring speed Push this key for two seconds.Beep 8.Auto Statis.Check Titr. lot number and sample size in weight Parameters can be set with this key.Serial/Version No. 5.Date&Time 2. GLP/GMP fully conforming 7.pH Polarity . Function key Set up functions as below: Key to return to the main screen display (standby state) 0. sample size. Setup items include: 0.pH Cal. Easy-to-enter colored key pad 9. Memory Clear 1. Set Check 2. Safety cover to protect burette 5. Periodic Check Key to switch displays or key functions and also used for auto input of sample size measured by an electronic balance APB Method Titration Control Result Sample Function 5 Key to enter sample number.Auto Start 10. Low cost but High performance 2. and the display shows setting stirring speed.Card Utility 14. Easy-to-read LCD with a backlight 3.Re-Titr.Data File 2. Method key Set Methods Titration key Set titration parameters Control key Set control parameters Result key Set calculation or print format Sample key Set parameters on a sample including the number of sample.Memory Clear Time and date can be set with this key. Sample File 5.Periodic 8.Changer 4. Selection of one or two burettes 6.Method File 1. 11.Language 6. S.0000 -100. EP detection range can be set.0000 7.S.5 (Slow) 100 200 300 Differential Slow : Control Speed (0.S.0 0. the speed slows down automatically. Delivery speed in titration can be automatically controlled.=0.0000 mL 13.0 mV Level mV -100. which is the most important target in titration.0000 mL 12. while it becomes larger. The endpoint whether single or multiple can be clearly indicated and separated in titration.0 0. 350. the speed increases. can be obtained from two detecting factors of dE (endpoint detecting potential) and dE/dmL (Max differential potential) without taking undesirable noise for endpoints. User can define titration volume and potential range.0) C.S. 350.00 3.0) C. most useful in measurement under the influence of noise and carbon dioxide.=2 (Medium) Medium : Control Speed (2.0000 mL 13. pH 0. Optimal control method in chemical reaction comes from the related combination of delivery speed and control speed : C.0000 14.5) 400 500 600 6 . Where titration potential change (differential) is smaller. For example.0000 mL 12.0 2.Features of KEM titrators 1. Level Stop mode can determine the detected single endpoint as EP2.00 4. Delivery speed s/mL 2 100 200 300 400 500 0 C. An endpoint can be detected precisely. Potential mV Differential -100.0 A precise endpoint.=4 (Fast) Fast : Control Speed (4.0000 0.0 350. which is adopted in conductometric titration or the like.0000 pH 0.00 pH 0. Up to 3 EPs can be detected by AT-500N and 5 EPs by AT-510.0000 Titration will last to the preset volume and finds endpoints. and titration volume will be displayed at given interval.0 4.0 380. Full EP stop Level Stop 320. which is adopted in photometric titration or the like.00 0. pH Stat 14.0000 mL 8. .5000 A pKa value can be determined by finding pH at the half of titration volume in neutralization titration.0 mV mV mV -80.8393 Titration will last up to the preset potential level (up to 2 levels) before stopping.0000 mL -100. This is useful for a sample of which endpoint number is unknown.0000 -130. 7 7. Titration will last until it finds preset number of endpoints defined by user on control parameter setup.0 12.00 mL Two-tangent lines crossing point is determined as the endpoint.EP detection forms Various detection forms can be selected suitable for users’ titration needs.5000 mL 0 7. Up to 3 EPs can be detected by AT-500N and 5 EPs by AT-510.0000 Two-tangent lines crossing point is determined as the endpoint.00 12000 pH 2.0000 mL 0:00:00 0:30:00 0. Auto Intersect 0.00 12.0000 Reagent is dosed to maintain control potential in Stat titration.0 350.0000 12.0 mL Auto Intersect 12.0000 mL 13. 0.4302 pKa 5. 0.00 2. KBrO3 98100M511 or 98100M512 / POT-510 Mercaptan Precipitation Titration AgNO3 98100M214&98100H171 Determination of Iodine Oxdation-Reduction Titration Na2S2O3 98100C272 HCIO4 98100H171&98100R172 Na(B(C6H5)4) or 98100C171 Acid-Base Titration Determination of Benzethonium chloride Ca and Mg in Dialysis solution Chelatometric Titration EDTA Photo Sensor / PTA-510 Chloride in pharmaceutical products Precipitation Titration AgNO3 98100C373 Acid value of beverages Acid-Base Titration NaOH 98100C171 Salts in seasoning/dressing Precipitation Titration AgNO3 98100C373 Vitamin C Oxdation-Reduction Titration indophenol 98100C272 NaOH 98100H171&98100R172 KOH or 98100C172 Boric acid concentration in nuclear power plant Electronic Power Electrode / Preamplifier Chloride Determination of Sodium acetate Medicine Titrant Acid-Base Titration Total Acid Number of insulating oils Acid Value Acid-Base Titration KOH 98100C173 Peroxide Value Oxdation-Reduction Titration Na2S2O3 98100C272 Saponification value Acid-Base Titration Hydroxy Value Metal Plating Solution Ni HCI 98100C173 KOH Chelatometric Titration EDTA Photo Sensor / PTA-510 Precipitation Titration AgNO3 98100C373 Acid-Base Titration NaOH 98100C171 Chromic acid in chrome plating bath Oxdation-Reduction Titration Na2S2O3 98100C272 Total hardness Chelatometric Titration EDTA Photo Sensor / PTA-510 Chloride Precipitation Titration AgNO3 98100C373 Alkalinity Acid-Base Titration H2SO4 98100C171 Metal Plating Solution Cu Electronic and Metal Planting Free cyanide concentration Boric acid in plating baths Etching Solution H2SO4 City water/ Industrial water Anionic Surfactants Detergents Chemicals Colloid Titration Cationic Surfactants 98100S173 SDS Determination of Isocyanate Acid-Base Titration HCI 98100C173 Monomer residues in polyethylene Oxdation-Reduction Titration Na2S2O3 98100C272 KOH 98100C173 HCI 98100C171 KOH 98100C173 Carboxyl group in PET resin Sodium hydroxide Acid-Base Titration Purity of acrylic acid Iron and steel/ Ceramics Hyamine Ferric iron in hydrochloric acid Oxdation-Reduction Titration Na2S2O3 98100C272 Fluoric acid and nitric acid in pickling solution Acid-Base Titration NaOH 98100C171 Trace chlorine in cements Precipitation Titration AgNO3 98100I 271&98100R272 Aluminum oxides in cements Chelatometric Titration EDTA Photo Sensor / PTA-510 8 .Applications of Automatic Titrators Type of Industry Object of Analysis Total acid number of petroleum products Titration Types Acid-Bass Titration Total base number of petroleum products Petroleum Foods Fats and Oils KOH 98100H171&98100R172 HCIO4 / HCI or 98100C173 Precipitation Titration AgNO3 98100C373 Bromine Number Polarization Titration NBr. titration Combined. (Option:PTA-510. pKa. 10. File for operator's name (up to 10) Integrated construction of main unit and burette. 5. Repeatability ±0. etc. temperature. Checking of burette precision. Redox. electrode 98100T111 1 Impact dot printer IDP-100 1 Electrode cable 984290012 1 Electrode cable 984290012 1 . COD titration control STD:4. 126 x 70 mm. IDP-100 style). POT-510. Setting of periodic Setting of periodic inspection interval. 50 20. CMT-510) STD-510. User:16. (Option:TET-510. Inspection history for titration performance (one point).005mL.005mL 5mL burette ±0. KF moisture and COD titration Auto: Max inflection point.02mL 20mL burette ±0. KF titration control. Manual: EP stop. Stirrer(984300018A) with a built-in preamplifier One built-in APB-510 and One built-in APB-510 (AT-500N-1) or up to 9 external APB-510 connectable two built-in APB-510 (AT-500N-2) Burette capacity: 20mL Burette capacity: 20mL Optional burettes (mL): 1. etc. IDP-100 Options: A4/letter-size printers Internal: 100 samples Internal: 100 samples External: 100 samples per PC card Calibration history for electrodes. Humidity: less than 85%RH (No condensing) AC100-240 V. Total 20 STD:7.000 steps 20. Repeatability ±0. pH stat.000 steps 50mL burette ±0. approx.015mL. potential. Inspection history for titration performance (one point). etc.01mL.001mL Automatic with ceramic cock PTFE. printer. electrode 98100T111 1 Temperature comp. Repeatability ±0. potential.003mL 1mL burette ±0. inspection interval. Total 50 Acid-base. Electronic balance. PTA-510. Messages. Photometric and Polarization Acid-base. Alarm for shortage of File for operator's name (one person) titrants. Repeatability ±0. temperature. Alarm for replacing electrodes. User:38. 10kg Instruction Manual 1 Instruction Manual 1 Rotor for stirrer(25mm) 985003141 1 Rotor for stirrer(25mm) 985003141 1 Piston removing stick 985515002 1 Piston removing stick 985515002 1 1 1 Combined glass electrode 98100C171 Combined glass electrode 98100C171 Temperature comp. Photometric. POT-510) LCD with back light. 16 digits by 2 lines Titration curves. 10. Intersection Level stop STD-510. etc.01mL 10mL burette ±0. Learning. Repeatability ±0. Auto control. 5. Polarization.Specifications Type and Model Titration mode Method Type of titration Titration form Preamplifiers Display Displayed contents External input/output Printer connection Data storage GLP/GMP conformity Structure Burettes Steps for a full stroke Burette precision Switching for discharge or suction Liquid contacting materials Ambient conditions Power/Consumption Dimension Weight Standard accessories 9 AT-510 Automatic Potentiometric Titrator AT-500N Automatic Potentiometric Titrator Blank. RS-232C. Ext. Titration parameters (titer. Level stop. Titration parameters (titer. glass and ceramics Temperature: 5 to 35°C. 50/60 Hz.). Auto cut off.02mL. Multiple sample changer Standard accessory: Impact dot printer (Ink-ribbon Options: Impact dot printer (Ink-ribbon style). 30W Main unit: 288(W) x 468(D) x 481(H) mm. 30 digits by 13 lines LCD with back light. Blank.). Redox. Messages. Continuous/Intermittent constant rate. 50 Optional burettes (mL): 1. Auto cut off. Intersection Auto: Max inflection point(Full or EP stop titration). Auto control. Combined:5. Stirrer unit: 118(W) x 225(D) x 336(H) mm Approx.05mL. Petroleum Continuous/Intermittent constant rate Products neutralization number. electrode not included 14pH 2000mV 0 120%T Photo sensor (530nm) included 0 14pH pH 0 2000mV 0 100 S 0 1000 S 0 10000 S Conductivity sensor included Exclusive for AT-510 14pH 2000mV 0 14pH Exclusive for AT-510 10 .System Configuration Temperature compensation sensor 984300054 SOFT-CAPE 984300036 Propeller stirrer MS-510 Magnetic stirrer APB-510 Automatic piston burette Standard system KF-510 Karl Fischer titration unit CHA-500 Multiple Sample Changer MW-510 Manual washing unit connecting cable 980305030 COD-510 COD titration unit APB-510 Automatic piston burette Magnetic stirrer 984300018A APB-510 Automatic piston burette connecting cable 980305030 MS-510 Magnetic stirrer connecting cable 980305030 MS-510 Magnetic stirrer MTA-118 Microtitration cell unit Burette Units APB-510-01B (1mL) APB-510-05B (5mL) APB-510-10B (10mL) APB-510-20B (20mL) Standard APB-510-50B (50mL) Sealed cell unit SCU-118 Preamplifier M o d e l Application Equipped as Detected properties STD-510 POT-510 PTA-510 CMT-510 TET-510 Potentiometric Polarization Photometric Conductometric 3-way titration Acid-base titration Redox titration Precipitation titration Non-aqueous titration Potentiometric titration at constant current Amperometric titration at constant voltage Acid-base titration Redox titration Non-aqueous titration Chelate titration Acid-base titration Redox titration Precipitation titration Non-aqueous titration Conductometric titration Acid-base titration Redox titration Precipitation titration Non-aqueous titration Acid-base titration Redox titration Precipitation titration Non-aqueous titration Option Standard Option Option Option 1 pH pH pH pH pH 2 mV mV mV mV mV Polar Potential/Current Transmittance Conductivity 3 Detection range 1 2 3 Remarks 0 14pH 2000mV 0 14pH 0 2000mV 0 2000mV 0 100 A Twin Pt. 98100S173 Surfactants used to be determine by the Epton's method with the toxic solvent of Chloroform. 11 Combination Surfactant Electrode CHA-500 Multiple Sample Changer 12 or 18 samples Standard: 200mL beaker or 300mL tall beaker Optional: 50. A number of samples can be automatically measured using the Multiple Sample Changer.Acid-base titration 2. Safety cover to protect glass burette. 10W . polymer coagulants and the colloid solution with dispersing charged particles in Food industry Measuring range 1x10-5M or more Output power -2 to +2 VDC Power source 100 to 240 VAC. Main specifications (not CE conformed) Item Specifications Measured objects Surfactants.Neutralization number titration on petroleum products Optional Power Shut-off Unit POU-310 can be connected with CHA-500. Easy replacement of valve with newly designed flowcontroll valve for titrants. Dip plus shower Standard: Pure water. Main specifications Item Concentration range pH range Temperature range Specifications 1x10-2M 1x10-5M pH2 12 0 50 C Stream Potential Titration Unit PCD-500 Titration instrument for measuring on surfactants and polymer coagulants.Standard non-aqueous titration 4. such as Lotus1-2-3.2 Features: Automatic Piston Burette Titration nozzle of burette is made of PTFE and two kinds of nozzle. but with this electrode one can measure the concentration of cationic or anionic surfactants quickly without Chloroform. 100mL beaker or 200mL Erlenmeyer flask Standard: Shower (equipped with rinse pot) Optional: Dip. APB-510 Specifications: Type and model Display Burette capacity Reagent bottle Power source Power consumption Dimension Weight APB-510. Microsoft® Excel must be installed on the connected personal computer. Ethanol or IPA (Isopropanol) Optional: Organic solvents such as toluene. anti-diffusion type and normal type. 5kg Features: Multiple Sample Changer Can select washing sequences for electrodes suitable for titration applications: 1. Aqueous acid/alkali solution Standard: Natural falling drain from rinsing pot Optional: Mixing/Separating drain by drain pump Standard: N/A Optional: APB-510 or filling pump can be connected to CHA-500. CHA-500-12/CHA-500-18 Specifications: Type and model Number of samples Sample vessels Rinsing method Rinsing solution Drain capabilities Dosing of pretreatment solution Data Capture Software SOFT-CAPE SOFT-CAPE the Data Capture Software for AT-510/AT-500N Automatic titrators Data Capture Software can control Automatic titrators.Precipitation titration 3. are given as standard accessories. Automatic Piston Burette LCD .Options for AT-510 and AT-500-1. Measurement results of Automatic titrators can be downloaded directly to workbook in Microsoft® Excel or filed in CSV format. capable six digits display 1)20mL glass burette (standard) 2)Unit with 50/10/5/1mL glass burette (option) 1000mL brown glass bottle 1) AC100~120 V or AC200~240 V 2) 50/60 Hz 20W 120(W) x 365(D) x 450(H) mm Approx. COD titration unit COD-510 COD titration unit COD-510 This unit is used for the titration with Potassium permanganate in the last step of COD measurement. 2. 3.Can store all data in PC card for backed up on a personal computer. control or calculation) prepared by us. DIN.Options for AT-510 and AT-500N-1. 2. titration conditions and other parameters. BS. The structure features the sealed jacket of thermostatic bath. based on international standards. In addition. Capacity of titration cell 200mL Minimum sample required At least 50mL Propeller stirrer 984300036 This unit features stirring titrated sample solution with rotating propeller at the tip of a motoring rod as the substitute for a magnetic stirrer. (Exclusive for AT-510 and AT-500N) Options Exclusive for AT-510 PC Card The following three types of PC cards are available: 1. NF and JIS.Measurement results can be directly captured to Microsoft Excel workbook.Memory card (984340039) Can store. 4.5mL 35mL 100mL SCU-118 Sealed Cell Flask Assembly This flask assembly with an electrode supporting holder is designed for samples that cannot be measured under normal ambient conditions. one can measure water in samples. Features: 1. sample vol. PC Card Read Software SOFT-PCRE KF titration unit KF-510 KF titration unit KF-510 With this unit and the Karl Fischer reagents. with pH temperature compensation tables of ASTM. 3.Measured data can be directly stored as files in CSV format. data stored in personal computer can be transferred to Memory card. sample vol.2 Micro Titration Assembly MTA-118 This assembly is useful for measuring trace amount of samples by titration. data stored in personal computer can be transferred to Memory card. Further.Personal computer can separately store and manage measured data.pH temperature compensation card (984340175) Can make temperature compensation on pH. 1mL 5mL 25mL Max. In reverse. 2. meaning that instrument can be easily recovered. can perform recalculation or statistical calculations by recalling measured data. This CSV file is compatible with Microsoft® Excel spreadsheet software package. measurement conditions or sample conditions stored in Memory card. 12 .Application card (984340173) Can use 70 various measurement conditions (parameters for such as titration. Type Cell shape MTA-118-1 Tube MTA-118-5 Cone MTA-118-50 Cone Min. read and write measurement methods. Titration can be performed with minimal influence of atmosphere by purging the inside of the flask with Nitrogen gas or filling the desiccant tube with Soda lime or the like. where the user can see and download data files on measurement conditions plus the up-to-date information on titration technique. 13 .jp/itsupport/.Multi-Channel software perfectly Software for Titrators supporting titration Can run four measurements simultaneously and concurrently. allowing operators to avoid unintended or ignorant entry of numerical constants such as sample size and the like. Additional powerful help by the Wizard enhances setting up measurement conditions through dialogue interactions. IT Support: Details of AT-Win can be viewed at http://www. the complete titration conditions can be set up automatically. Auto settings of measurement conditions with the Navigating feature: Just by entering user’s intended main criteria including international standard (e. 3. ISO). Operational procedures displaying feature: Simply select what you want to do-. ASTM. 2. AT-510 AT-500N-1 AT-500N-2 Examples of connection of AT-510/AT-500N Automatic Potentiometric Titrators Features 1.g.kem.the necessary procedures for user’s desired measurement will be displayed sequentially prompting the entry step by step. JIS. measured object and measuring range. Can display four titration curves simultaneously. sample type. for example. the user can create Report easily and faster than before in one's original form. edit. GLP/GMP fully conforming: Electrode and sensor Notice of periodic calibration date Display of electrode calibration records Burette validation Notice of periodic check date Display of burette validation record Notice of piston head replacement date Check with standard substance Notice of periodic check date Display of check records Others Operational level authentication by user Display of operational records Alarm for remaining reagent volume 5. recalculation or analysis can be manipulated by other computers installed with Viewer via LAN linked. but also the simulation of measurements. Creating Report: Since titration data are now converted to CSV format. copy or delete titration conditions of Methods. Of course. 7. 8. 14 . 6. Therefore. Barcode reader: Sample ID or lot number can be easily input with a barcode reader sold on the market connectable to the keyboard of user’s personal computer. <The range of authentication of operational level> Create. Standard-equipped Viewer linked to Network: Not only measurement results can be viewed. making use of its template and macro.Operational management with security measures: User ID and password security support operational management allowing solely managerial person to change parameters in order to avoid illegal or unauthorized alteration of measurement conditions or the like. using Microsoft Word's auto function. GLP/GMP requirements including electrode calibration and burette validation. the user can create report and print it out with the Microsoft Word. Analysis of measurement data like re-calculation or re-detection of endpoints. The Viewer can be installed on plural personal computers.Features 4. they can be manipulated in other application software like Microsoft ® Excel spread sheet or Microsoft Access database software on the word-processing Microsoft Word. CH1 Key Code Card CH2 CH3 CH4 CH5 CH6 CH7 CH8 Connecting cable (2m) 980300002 AT-Win/2nd(Add-on Set) KEM Printer Key Code Connecting cable (2m) 980300002 AT-510 Automatic Potentiometric Titrator APB-510 Automatic Piston Burette APB-510 Automatic Piston Burette (Max 9 connectable) MS-510 Magnetic Stirrer AT-510 Automatic Potentiometric Titrator Key Code Card AT-500N Automatic Potentiometric Titrator APB-510 Automatic Piston Burette APB-510 Automatic Piston Burette (Max 9 connectable) CHA-500 Multiple Sample Changer APB-510 Automatic Piston Burette 980305030 connecting cable 980303388 connecting cable CHA-500 Multiple Sample Changer 15 APB-510 Automatic Piston Burette 980300013 connecting cable MS-510 Magnetic Stirrer CH9 . Board (984040008).System Configuration Standard components KEM Titration software AT-Win Key Code When purchasing AT-Win/2nd software. you need RS-232C EXT. System requirements: Device Computer Description Personal computer with CPU of 500MHz or better * Intel Pentium/Celeron family. AMD K6-2/Athlon/Duron family or Intel compatible CPU’s Operating system Windows 98SE/Me/2000/NT4. 3) If a PC has a built-in modem. Additionally. one serial port may be already assigned. Low Profile type of PCI bus may not be compatible. Options: RS-232C EXT.0 or later) RAM Free hard disk space 128MB or more 50MB or more free disk space Display Resolution of 1024x768 or better Disk drive Serial port CD-ROM or DVD-ROM RS-232C D-sub (male) 9 pin or USB port: 1 port *2 *2 1) Each titrator has to have an extra serial port. No Connecting cable(2m) 980300002 1 Key Code Card Operation manual Connecting cable(2m) 980300002 1 1* 1* 1 copy No * For the purchase of a Key Code Card. This serial number must be notified by the user when used in combination with the unit already in use. a separate serial port will be required in the computer accordingly. Board Extension cable (For AT-510/AT-500N) Extension cable (For AT-420N) 984040008 RS-232C expanded serial port (8ch.01 or later) Adobe Acrobat Reader (Version 4.Specifications Standard components: Name of software Compatible model Media Connecting cable AT-Win AT-Win/2nd Base set Add-on set AT-510/AT-500N AT-510/AT-500N CD-ROM 1 pc. however. the serial number of user's unit is required. up to four (4) titrators can be linked through the interface. converting cable included) 980080003 980080004 980305289 983500005 983500006 Connecting cable set (120 VAC) 10m Connecting cable set (230 VAC) 10m TCU cable (10m) Optical cable (30m) Optical cable (50m) 980305287 980305288 980305289 983500005 983500006 TCU cable (1m) TCU cable (5m) TCU cable (10m) Optical cable (30m) Optical cable (50m) 16 . Note. Likewise. that at least one slot must be free on PCI bus. 2) With the optional RS-232C expanded serial port. when a balance or barcode is connected to a PC.0(SP5 or later)/XP Other programs Microsoft Internet Explorer (Version 5. FDA 21 CFR Part 11 Compliant Software Security Integrity AT-Win/ER Titration Software featuring Electronic Records and Signatures compliant with FDA 21 CFR Part 11. be sure to let us know the serial numbers of the concerned AT’s. 17 . For more details. Search the recorded data Direct backup recording in CD-R or other device Backup data can be viewed directly. Note: Hardware validation is required for user’s computers on which this software is installed. Oracle) Can see stored and compressed data with Viewer Record created or changed Methods with comments Auto recording of results and re-evaluated data with all changes noted. Oracle. report of the serial number on a user’s AT unit is a must. Adobe Systems and Shimadzu Ltd. “Oracle”. Audit Trail Electronic Signatures Software specifications: Item Description Name of software User authentication Electronic signatures FDA 21CFR Part 11 compliant features Data integrity Audit trail Backup function GLP/GMP compliant features Network link Compatible models AT-Win/ER. MSDE and SQL Server”. please contact our local sales representatives in your country. 980300002 1piece 1* One copy Add-on set No No 980300002 1piece 1* No * For the issue of a Key Code Card. inheriting proven user-friendly and competent features of AT-Win Software for titrators. Internet Explorer. FDA 21 CFR Part 11 Compliant Software Login ID and Password security User name and title registration Group management for up to 11 user groups Password valid period Detection of illegal access and lockout (access number counting and its time length) Signatures according to users’ authentication Verified data is stored in database with comments Auto recording raw data and meta data in database Auto recording measurement parameters and results (Database:compatible with the Microsoft SQL Server/MSDE. When this software is used with the formerly delivered AT units. CD-ROM 1 pc. Standard components: Name of software Media Connecting cable Key Code Card Operation manual Titration software Database controlling software AT-Win/ER AT-Win/2nd Base set CD-ROM 1 pc. “Acrobat” and “CLASS-Agent” are registered trademarks of Microsoft. Electrode calibration/Check with standard substances/Validation of burette dosing volume Notify Periodic calibration/check/validation (by setting date or its interval) Auto recording of the results of calibration/check/validation in database Interface to the Shimadzu CLASS-Agent System AT-510 and AT-500N * “Windows. respectively.. which can be electronically signed according to an approved workflow. which is traceable by the function of log file self-generation. etc. Electronic signatures with ID and Password security User authentication is secured by login/logout with ID and password. 4. 2. Secured data integrity Database management of user information (name. Illegal access is prevented by lockout system which records the attempt. electrode calibration or check with standard substances are automatically recorded onto the database. also compatible with the LAN on Client/Server system. the feature includes the interface to the Shimadzu LC/GC Network. 3. e-mail address. Network compatibility The network-interfacing feature.Features 1. User group registration Up to 11 separate user groups can be registered. 5. allows the users to control their login records. In addition. Electronic records and signatures Data such as measurement results or conditions. each with its own password entry and individual level of access. Backup system The backup copies of data and log records together with the reasons can be made on commercial media such as CD-R using a CD-R/RW drive and a CD writing software. Audit trail The required audit trail feature is fully compliant by recording data both before and after the change. Database 18 . 6. The password length and validity period can be precisely set for each user.) can be secured at higher level by linking the access-controlled database such as Microsoft SQL Server/MSDE or Oracle. title. Titration result 7. CH1 KEM Key Code Key Code Card Database management software CLASS-Agent Connecting cable (2m) 980300002 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 AT-Win/2nd(Add-on Set) KEM Key Code Key Code Card Connecting cable (2m) 980300002 Printer AT-510 Automatic Potentiometric Titrator AT-510 Automatic Potentiometric Titrator APB-510 Automatic Piston Burette APB-510 Automatic Piston Burette (Max 9 connectable) MS-510 Magnetic Stirrer AT-500N Automatic Potentiometric Titrator APB-510 Automatic Piston Burette APB-510 Automatic Piston Burette (Max 9 connectable) CHA-500 Multiple Sample Changer APB-510 Automatic Piston Burette MS-510 Magnetic Stirrer 980305030 connecting cable 980303388 connecting cable CHA-500 Multiple Sample Changer APB-510 Automatic Piston Burette 980300013 connecting cable Distributed by : KYOTO ELECTRONICS MANUFACTURING CO.LTD.. Phone : +81-3-3239-7333 URL : http://www. Server PC Client PC Client PC Ethernet LAN (Labo) Ethernet LAN (Office) When used as stand alone PC. 58IK33C . Overseas Division : 8-3 Niban-cho Chiyoda-ku TOKYO 102-0084. Printed in Japan. you need RS-232C EXT. Board (984040008).JAPAN Fax : +81-3-3237-0537.com Specifications and design subject to change for improvements without notice.kyoto-kem. Database Standard components FDA21CFR Part11 Compliant software When purchasing AT-Win/2nd software.System Configuration Database LC/GC.etc. the database should be installed on a local PC.
Copyright © 2024 DOKUMEN.SITE Inc.