ARRANCADOR BENSHAW

May 26, 2018 | Author: Julio Pizarro Anco | Category: Watt, Relay, Electrical Engineering, Manufactured Goods, Electromagnetism


Comments



Description

2013 Product CatalogAdvanced Controls & Drives Effective April 1, 2013 SECTION 1 Medium Voltage Variable Frequency Drives SECTION 2 Low Voltage Variable Frequency Drives SECTION 3 Medium Voltage Starters SECTION 4 Low Voltage Starters http://benshaw.cwfc.com 24/7/365 Service and Support Field Services • Installations & commissioning • On-site repairs - Scheduled/emergency • On-site retrofits and upgrades Factory Services • Send-in repairs - Scheduled/emergency • Send-in retrofits and upgrades • Quick ship modified —  Benshaw Express stock • Benshaw and 3rd party Technical Training • In-class in our training center • In-class at your facility • Customized for your business Maintenance Services • Thermography • Service contracts • Preventive - Maintenance / agreements • Power quality Spare Parts • 24/7/365 availability • Emergency delivery - Courier available • Replace or repair Technology Retrofits • Solid state motor controls and drives • Electromechanical motor controls • Orphaned OEM equipment retrofits .....................................................27 Solid State Starters with Two Speed Control.....25 Synchronous Starters.26 Solid State Starters with Reversing Control..................................................7 Prepackaged Starters........BenshawExpress.................................................com 4-1 .................................Low Voltage Starters Standard Low Voltage Starter Products MX3 Controller...................4 Open Chassis Solid State Starters.....................................2 MX2 Controller..................29 To order WEB STOCKED items: visit www.......................................................28 Solid State Starters..................16 Engineered Low Voltage Starter Products Wound Rotor Starters....... greater capabilities expandability and a broader communications capability than any • Intelligent SCR power poles other motor control on the market. flexible architecture—Benshaw’s MX3 controller delivers unprecedented functionality and all of the rugged. dependable • Flexible.Standard Low Voltage Starter Products Intelligent Motor Control mx3 controller KEYPAD (INCLUDED) FIBER OPTIC FIRING OPTIONAL RTD • Integrated technology MODULES • Noise immunity • High voltage isolation • Safe. power components. more configurable options. improve motor performance and protection. enhanced programming capabilities. programmable I/O performance you’ve come to expect a the world leader in solid state • Integrated motor protection motor controls and drives. ease of use. enhance diagnostic capability and streamline many electrical system monitoring and maintenance tasks. NEC. and • Patented CYCLO Converter control from 1 to 40% speed a unique. software and sensors are all and real-time clock designed. • UL. With fiber with multiple starting modes built-in optic firing. To order: call 412-968-0100 4-2 . NEMA compliance eliminating the coordination and performance problems inherent in • Built-in remote self-testing (BIST) other forms of reduced voltage starting. • Expanded communications With more built-in features. • Line and motor metering • Diagnostic capabilities with event log MX3 controllers. built and tested to perform as an integrated control system. Benshaw’s next generation MX3 • Intelligent MV MCC integration technology will shorten your commissioning times. CUL. reliable SCR control Highlights: Key Features: Next generation MX technology forms the backbone of Benshaw’s 3 • High performance motor control entire line of intelligent medium voltage motor controls. com 4-3 .BenshawExpress. voltage and • Up to speed timer • Locked out frequency exceeded • KW hours • Over current - Start and stop the solid • Low line voltage • MW hours • Under current state starter • Low line frequency • Phase order • OL alarm 1 Communication Port: • High line frequency • Line frequency • Shunt trip • ModBus / RS485 • Phase reversal • Analog input • Ground fault • Phase loss • Analog output Advanced Functionality: • Energy saver indication • Instantaneous overcurrent • Run time — days • Dual ramp selection • Heating indication • Overcurrent • Run time — hours • Adjustable kick current • Slow speed forward/ • Undercurrent • # of starts reverse • Programmable decel modes • Current imbalance • Tru Torque % • DC braking • MV BIST test • Ground fault (residual or • Power % • Cooling fan (built-in self test) zero sequence) • Peak starting current • Shorted or open SCR • Last starting duration • Disconnect fault • RTD temperatures • Inline contactor fault • Real-time clock To order WEB STOCKED items: visit www. • VARS line current.Standard Low Voltage Starter Products Intelligent Motor Control mx3 controller control features Multiple Starting Modes: • Control power low 8 Digital Inputs 1 Analog 4 – 20 mA / • Voltage ramp • Stack over temperature Configurable to: 0 – 10 Vdc Input • Stop Configurable to: • Current ramp • Motor PTC input • Fault • Trip high level - Adjustable initial current • RTD modules • Fault reset • Trip low level - Adjustable maximum Metering: current • Bypass / inline confirm 1 Analog 4 – 20 mA / • Accuracy: 0 – 10 Vdc Output - Adjustable ramp time • OL reset - 3% out-of-box Configurable to: • Torque ramp (TruTorque) • Local/remote selection - 2% factory calibrated • Current - Adjustable initial torque • Heater enable (0 – 200%/0 – 800%) • Average current - Adjustable maximum • Heater disable • Voltage (0 – 150%) torque • L1 current • Dual ramp selection • OL (0 – 150%) - Adjustable ramp time • L2 current • 1 dedicated start input • kW (0 – 10 kW/0 – 100 kW) • Power ramp • L3 current • Disconnect • MW (0 – 1 Mw) - Adjustable initial torque • Current imbalance % • Slow speed • Analog input (0 – 100%) - Adjustable maximum • Ground fault current • Brake enable • Firing (0 – 100%) torque • Average volts • Brake disable • Calibration - Adjustable ramp time • L1 – L2 voltage • Linear/tach feedback • L2 – L3 voltage 6 Relay Outputs User Interface: control Configurable to: • L3 – L1 voltage • Event log (99 events) • CYCLO converter control • Faulted • Overload % • Door mounted LCD • Running display Motor Protection: • Power factor • Up to speed - Set/examine operating • Motor thermal overload • Watts • Alarm condition parameters • Independent starting and • VA running OL’s • Ready condition - View status information. user selectable starting modes. • Residual ground fault • Advanced line / motor metering The new control board terminal configuration—coupled with program- • DC braking light duty mable burden CT settings—makes Benshaw’s MX2 technology an • Power stack thermistor excellent choice for a wide range of intelligent. MX2-based • 3 user configurable output relays and 1 fixed bypass confirm controls offer multiple. an increased • User configurable analog I/O selection of configurable digital and analog I/O’s. intelligent low voltage motor control platform. soft start motor control. more built-in protection features. unprecedented onboard protection and an • Programmable burden CT settings easy to use. • Remote keypad ready cost. soft start motor control applications. • 1000V capable additional communications capabilities. improved noise immunity. • Data snapshot of each fault • Power up on start With more built-in starting modes. • CE. a • Energy saver more complete user I/O and CE compliance. CUL. NEMA compliance • Built-in self-testing (BIST) When you factor in our 24/7 comprehensive technical support. Benshaw’s new MX2- based low voltage motor controls raise the bar for intelligent.Standard Low Voltage Starter Products Intelligent Motor Control mx2 controller OPTIONAL KEYPAD MX2 BOARD Standard Features: • High performance motor control with multiple starting modes built in • Jogging 7 and 14% speed • 3 user configurable digital inputs Highlights: • 2 fixed inputs for start and bypass confirm The new MX control technology from Benshaw provides a powerful. comprehensive built- in metering capabilities. low. • ModBus 485 plus expanded we think you’ll find Benshaw’s MX2-based controls to be an communications capabilities with excellent value. UL. intuitive user interface. optional bridges To order: call 412-968-0100 4-4 . 2 flexible. • Up to speed timer exceeded • Phase order • Under current trip voltage and frequency in real time • Low line voltage • Line frequency • OL alarm - Start and stop the solid • Low line frequency • Analog input • Shunt trip fail safe and state starter • Analog output non fail safe • High line frequency • Ground fault 1 Communication Port: • Phase reversal • Run time — days • Energy saver indication • ModBus / RS485 • Phase loss • Run time — hours • # of starts • Heating indication Advanced Functionality: • Instantaneous overcurrent • Tru Torque % • Slow speed forward/ • Dual ramp selection • Overcurrent reverse • Undercurrent • Power % • Adjustable kick current • DC braking • Current imbalance • Peak starting current • Programmable decel • Cooling fan modes • Ground fault residual • Last starting duration • 1 fixed bypass • LV BIST test (built-in • Shorted SCR self test) To order WEB STOCKED items: visit www.Standard Low Voltage Starter Products Intelligent Motor Control mx2 controller control features Multiple Starting Modes: • Disconnect fault 3 Digital Inputs 1 Analog 4 – 20 mA / • Voltage ramp • Inline contactor fault Configurable to: 0 – 10 Vdc Input • Stop Configurable to: • Current ramp • Control power low • Fault • Trip high level - Adjustable initial current • Stack over temperature • Fault reset • Trip low level - Adjustable maximum Metering: current • Bypass/confirmation & 1 Analog 4 – 20mA • +/.2% accuracy inline / 0 – 10Vdc Output - Adjustable ramp time • Average current • OL reset Configurable to: • Torque ramp (True Torque) • L1 current • Local/remote selection • Current - Adjustable initial torque (0 – 200%/0 – 800%) • L2 current • Heater enable - Adjustable maximum • Voltage (0 – 150%) torque • L3 current • Heater disable • OL (0 – 150%) - Adjustable ramp time • Current imbalance % • Dual ramp selection • kW (0 – 10 kW/0 – 100 kW) • Power ramp • Ground fault amps/ • 1 dedicated start input residual • MW (0 – 1 MW) - Adjustable initial torque • 1 dedicated bypass • Average volts • Analog input (0 – 100%) - Adjustable maximum 3 Relay Outputs torque • L1 – L2 voltage • Firing (0 – 100%) Configurable to: - Adjustable ramp time • L2 – L3 voltage • Calibration • Starter off • Linear/tach feedback • L3 – L1 voltage User Interface: • Faulted fail safe and non control • Overload % fail safe • Standard board-mounted • Jogging 7 and 14% • Power factor • Running LED interface speed • Watts • Up to speed • Optional remote mount Motor Protection: LCD display • VA • Alarm condition • Motor thermal overload - Set/examine operating • VARS • Ready condition parameters • Independent starting and • KW hours • Locked out running OL’s - View status information • MW hours • Over current trip - View line current.com 4-5 .BenshawExpress. of Auto Resets Before Lockout   LV BIST   Decel After Fault   MV BIST   Fault Log   LV Powered BIST   Time and Date Stamp  9 Data Snapshots of Each Fault   Event Log (last 99 events)  Fault Classes To order: call 412-968-0100 4-6 . No.Standard Low Voltage Starter Products Intelligent Motor Control mx3 / mx2 controllers control feature comparison MISCELLANEOUS MX2 MX3 PROTECTION MX2 MX3 USER I/O MX2 MX3 Voltage Ramp   Separate Starting/Running Programmable Digital Inputs   Current Ramp   Overload Classes   Programmable Digital Outputs   TruTorque™ Ramp   Adj. Auto Fault Reset Timer   MISCELLANEOUS MX2 MX3 Adj. Cooling Time   Programmable User Analog Output   Tach/Speed Control Ramp  Intelligent Start Lockout  Local/Remote Source Input   Linear Ramp Profiles   Adj. Ground Fault Protection  KVA Meters   0-40% speed   Starts Per Hour  VAR Meter   Inside Delta   RTD Monitoring  Watt Hour Meters   Wye-Delta/Electromechanical Control   Motor PTC  Line Frequency Meter   Phase Controller   Stack OT Switch   Power Factor Meter   Current Follower   Stack Thermistor Input   % OL Meter   ATL   Backspin Timer  Time Until OL Lockout Release Meter   Time Between Starts  Phase Rotation Meter   Phase Rotation   & Power and % TruTorque™ Meter   Overvoltage   Run Time Meter   Undervoltage   Number of Starts Meter   Phase Loss   Peak Current of Last Start Meter   UTS/Stall Timer   Last Starting Time Meter   Zero Speed Switch  Analog Input Meter   PF Trip  Real Time Clock  PORT (Power Outage Ride Through)  RTD Meters  Keypad Fault Reset   Adj. Hot/Cold Ratio   User Analog Input   Power Ramp   Adj. OL Lockout Level  Power Up Start   Squared and S Ramp Profiles  Over/Under Current Protection   Dual Ramps   Retained OL When Power Lost   METERING MX2 MX3 Kicking   Current Imbalance Protection   Full Voltage and Current Metering   Voltage Decel   IOC (Instantaneous Over Current)   True RMS Calculation   TruTorque™ Decel   Open/Shorted SCR Detection   Factory Menu Calibration   DC Braking   Overcurrent/Shear Pin   Current Imbalance Meter   Heater/Antiwindmill   Undercurrent/Load Loss   Ground Fault Meter   Jogging 7-14% Speed   Residual Ground Fault Protection   Watt Meters   Slow Speed Cyclo™ Operation Zero Seq. The MX2 or MX3 series control provides users with a powerful group of programming parameters.200 hp / 600 Vac Key Advantages: • Economical at low horsepower • High duty cycle starting • Long starting times • Suitable for jogging applications • Fan cooled stack • Energy saver applications • Integrated motor protection • Modbus standard / Profibus. In addition. To order WEB STOCKED items: visit www. fan cooled RC applications stack.com 4-7 . continuous duty. DeviceNet. Ethernet. 1–1. The RC power section is a rugged non-bypassed section. Ethernet IP web addressable communication protocols are available via optional communication bridges • 1. It is an eco- nomical solution at low horse-power.Standard Low Voltage Starter Products Open Chassis Solid State Starters rc series with mx3 or mx2 Technology non-bypassed / continuous duty.BenshawExpress.25 service factor Highlights: • Integrated metering and diagnostics The RC Series Solid State Starter combines the high performance • Multiple starting ramps for various MX2 or MX3 control with the rugged. The MX2 and MX3 both provide simple setup and commission- ing via the Quick Start Menu. designed for flexibility in industrial applica- tions. the fan cooled stack provides high duty cycle and high inertia starting and energy saver operation. 9 150  RC3-0-S-515A-36C 515 200 - 450 - 36. ## Built-to-order: Please allow one week for shipment.200 hp / 600 Vac 500% Current for 30 Sec.Standard Low Voltage Starter Products Open Chassis Solid State Starters rc3 series with mx3 Technology non-bypassed /continuous duty.9 60  RC3-0-S-414A-35C 414 150 - 350 - 26 22 10. with chassis.5 160 • Unit requires separate 120 V control power. • Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.9 55  RC3-0-S-361A-35C 361 125 150 300 400 26 22 10.7 18  RC3-0-S-065A-32C 65 20 25 50 60 18 10 10.4 18  RC3-0-S-096A-33C 96 30 - 75 100 27 10 10. 1–1.8 29 11. KPMX3CBL2M. / 125% Continuous Rated Horsepower Dimensions (in.) Weight Model Number A (lbs.5 10 20 25 14 9.4 45  RC3-0-S-156A-34C 156 50 60 125 150 24 22 10.9 8.8 29 11.9 45  RC3-0-S-180A-34C 180 60 75 150 200 24 22 10.9 45  RC3-0-S-240A-35C 240 75 100 200 250 26 22 10. Catalog Number Description KPMX3CBL2M NEMA 12/3R Remote Keypad w/ 2 Meter cable A340D Chassis Mounted Display MX2 To order: call 412-968-0100 4-8 .9 55  RC3-0-S-302A-35C 302 100 125 250 300 26 22 10.9 8.4 19  RC3-0-S-125A-34C 125 40 50 100 125 27 10 10.7 15  RC3-0-S-040A-31C 40 10 15 30 40 14 9.5 150  RC3-0-S-590A-36C 590 - 250 500 600 36. Please order part number.9 8.7 15  RC3-0-S-052A-31C 52 15 20 40 50 14 9.) 208 V 240 V 480 V 575 V H W D  RC3-0-S-027A-31C 27 7.4 18  RC3-0-S-077A-32C 77 25 30 60 75 18 10 10. The keypad is shipped loose.9 150  RC3-0-S-477A-35C 477 - 200 400 500 26 22 10. 1 150  RC2-0-S-515A-36C 515 200 - 450 - 36.1 45  RC2-0-S-240A-35C 240 75 100 200 250 26 22 10.9 7.) Weight Model Number A (lbs.8 29 10.5 10 20 25 14 9.1 45  RC2-0-S-180A-34C 180 60 75 150 200 24 22 10.6 45  RC2-0-S-156A-34C 156 50 60 125 150 24 22 10.9 7.9 7.1 55  RC2-0-S-302A-35C 302 100 125 250 300 26 22 10.BenshawExpress.7 160 • Unit requires separate 120 V control power.8 29 10.7 150  RC2-0-S-590A-36C 590 - 250 500 600 36.9 15  RC2-0-S-040A-31C 40 10 15 30 40 14 9. ## Built-to-order: Please allow one week for shipment. Catalog Number Description KPMX3CBL2M NEMA 12/3R Remote Keypad w/ 2 Meter cable A340D Chassis Mounted Display MX2 To order WEB STOCKED items: visit www. / 125% Continuous Rated Horsepower Dimensions (in. • Unit includes standard board-mounted LED interface.6 18  RC2-0-S-077A-32C 77 25 30 60 75 18 10 9.9 18  RC2-0-S-065A-32C 65 20 25 50 60 18 10 9.1 60  RC2-0-S-414A-35C 414 150 - 350 - 26 22 10.6 18  RC2-0-S-096A-33C 96 30 - 75 100 27 10 9.1 55  RC2-0-S-361A-35C 361 125 150 300 400 26 22 10. The keypad is shipped loose.200 hp / 600 Vac 500% Current for 30 Sec.Standard Low Voltage Starter Products Open Chassis Solid State Starters rc2 series with mx2 Technology non-bypassed /continuous duty.9 15  RC2-0-S-052A-31C 52 15 20 40 50 14 9. 1–1.6 19  RC2-0-S-125A-34C 125 40 50 100 125 27 10 19.) 208 V 240 V 480 V 575 V H W D  RC2-0-S-027A-31C 27 7. The optional LCD interface is shown.com 4-9 .1 150  RC2-0-S-477A-35C 477 - 200 400 500 26 22 10. integral • Modular power stack assembly for bypass RB series power section.10 . efficient efficient operation. eliminating the profile. • Integrated metering system diagnostics The RB power section is a rugged. The modular design includes separate poles for each phase need for external fans for ease of maintenance. Both MX2 and MX3 controls provide applications simple setup and commissioning via the Quick Start Menu. compact design mance MX2 or MX3 technology with a rugged. ease of maintenance • ModBus standard / other Fieldbus The MX2 or MX3 technology provides users with a powerful group optional of programming parameters.Standard Low Voltage Starter Products Open Chassis Solid State Starters rb series with mx3 or mx2 Technology with integral bypass NEMA 2-HOLE SCR’s IN REVERSE PATTERN PARALLEL Dv/DT (BOTTOM ENTRY/ CONFIGURATION PROTECTION NEMA 2-HOLE PATTERN BOTTOM EXIT) (TOP ENTRY/TOP EXIT) STACK INTEGRAL BYPASS OVER-TEMPERATURE CONTACTOR RB Power Pole — 180A PROTECTION Highlights: Key Advantages: Benshaw’s RB series solid state starter combines the high perfor. compact. • Integrated motor protection • Dual ramp capability for loaded / unloaded applications • Power stack has multiple ratings for application flexibility To order: call 412-968-0100 4 . heavy duty solid state starter sec- • Integral bypass contactors for tion designed with integral bypass contactors for a compact. • Small. designed for flexibility in across a wide • Multiple starting ramps for various range of industrial applications. 5 10.3 9.4 18.3 12. 125% Continuous RB2-1-S-052A-11C - 15 - - 14 10 6.9 RB2-1-S-040A-11C 10 15 30 40 14 10 6.9 500% for 30 Sec. RB2-1-S-052A-12C 15 20 40 50 14 10 6.6 RB2-1-S-180A-14C 60 75 150 200 21.7 RB2-1-S-096A-13C 30 40 75 100 15 10 7.9 RB2-1-S-096A-13C 25 30 60 75 15 10 7.6 18.4 9.6 18.6 12.5 10.5 15 20 14 10 6.9 RB2-1-S-515A-17C 200 - 450 - 27.6 18.5 10.6 RB2-1-S-180A-15C 50 60 125 150 21.5 12.BenshawExpress.) Model Number 208 V 240 V 480 V 575 V H W D STANDARD DUTY RB2-1-S-027A-11C 7.9 350% for 30 Sec.3 12.6 RB2-1-S-361A-16C 125 150 300 400 24.5 10.6 18.9 RB2-1-S-720A-19C 250 300 600 700 29.6 RB2-1-S-156A-14C 50 60 125 150 21.9 RB2-1-S-077A-13C 25 30 60 75 15 10 7.3 12.3 12.9 RB2-1-S-720A-19C - 250 500 600 29.6 RB2-1-S-180A-15C 60 75 150 200 21.6 RB2-1-S-240A-15C 75 100 200 250 22.6 RB2-1-S-414A-17C 150 - 350 - 27.5 10.4 18.9 RB2-1-S-838A-20C 300 350 700 800 27.9 115% Continuous RB2-1-S-065A-12C 20 25 50 60 14 10 6.3 9.7 RB2-1-S-125A-14C 40 50 100 125 19.4 9.9 RB2-1-S-040A-11C 10 15 30 40 14 10 6.8 12.3 12.6 18.11 .6 RB2-1-S-302A-15C 100 125 250 300 22.5 9.3 12.5 9.9 RB2-1-S-590A-18C - 250 500 600 27.3 9.7 RB2-1-S-180A-15C 30 40 75 100 21.5 10.9 To order WEB STOCKED items: visit www.9 RB2-1-S-590A-18C 150 200 450 500 27.5 HEAVY DUTY RB2-1-S-027A-11C 7.7 RB2-1-S-156A-14C 40 50 100 125 21.9 600% for 30 Sec.9 RB2-1-S-590A-18C 200 200 450 500 27.3 9.5 10. 125% Continuous RB2-1-S-052A-12C 15 20 40 50 14 10 6.6 RB2-1-S-361A-16C 60 75 150 200 24.6 RB2-1-S-361A-16C 75 100 200 250 24.8 12.com 4 .6 RB2-1-S-414A-17C 100 125 250 300 27.6 13.5 10.9 RB2-1-S-040A-11C 10 10 30 40 14 10 6.5 10.Standard Low Voltage Starter Products Open Chassis Solid State Starters rb series with mx3 or mx2 Technology product selection guide Horsepower Dimensions (in.5 10 20 25 14 10 6.3 9.6 13.6 13.6 18.5 10 20 25 14 10 6.8 26.6 18.9 RB2-1-S-096A-13C 30 40 75 100 15 10 7.3 9.3 9.4 9.9 SEVERE DUTY RB2-1-S-027A-11C 5 7.5 10.9 RB2-1-S-477A-17C - 200 400 500 27.6 RB2-1-S-414A-17C 125 150 300 400 27.6 18. 9 18 11.9 159  RB3-1-S-720A-19C 720 250 300 600 700 30. with chassis. The keypad is shipped loose.1 26.3 160 • Unit requires separate 120 V control power.8 43  RB3-1-S-240A-15C 240 75 100 200 250 23.7 14 9.1 51  RB3-1-S-361A-16C 361 125 150 300 400 23.7 18 11.12 .9 151  RB3-1-S-477A-17C 477 - 200 400 500 28.9 18 11.9 155  RB3-1-S-590A-18C 590 - 250 500 600 28. Catalog Number Description KPMX3CBL2M NEMA 12/3R Remote Keypad w/ 2 Meter cable A340D Chassis Mounted Display MX2 To order: call 412-968-0100 4 .8 43  RB3-1-S-180A-15C 180 60 75 150 200 21.9 18 11.2 17  RB3-1-S-065A-12C 65 20 25 50 60 15 10 9.9 18 11.9 13.) 208 V 240 V 480 V 575 V H W D  RB3-1-S-027A-11C 27 7.8 12.3 9. Please order part number.4 10 56  RB3-1-S-414A-17C 414 150 - 350 - 27. / 115% Continuous Rated Horsepower Dimensions (in.2 17  RB3-1-S-096A-13C 96 30 40 75 100 15 10 9.) Weight Model Number A (lbs.2 18  RB3-1-S-125A-14C 125 40 50 100 125 21. KPMX3CBL2M.7 43  RB3-1-S-156A-14C 156 50 60 125 150 21. • Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.8 12.8 43  RB3-1-S-180A-14C 180 60 75 150 200 21.5 10 20 25 14 10 7.5 11.4 14  RB3-1-S-052A-12C 52 15 20 40 50 14 10 9.2 17  RB3-1-S-077A-13C 77 25 30 60 75 15 10 9.1 13.5 12.5 14.7 14  RB3-1-S-040A-11C 40 10 15 30 40 14 10 8.5 11. ## Built-to-order: Please allow one week for shipment.1 51  RB3-1-S-302A-15C 302 100 125 250 300 23.7 159  RB3-1-S-838A-20C 838 300 350 700 800 29.7 14 9.Standard Low Voltage Starter Products Open Chassis Solid State Starters rb3 series with mx3 Technology standard duty / 200–600 volt 350% for 30 Sec.9 155  RB3-1-S-515A-17C 515 200 - 450 - 28.3 9.  Web stocked Catalog Number Description KPMX3CBL2M NEMA 12/3R Remote Keypad w/ 2 Meter cable A340D Chassis Mounted Display MX2 To order WEB STOCKED items: visit www.1 151  RB2-1-S-477A-17C 477 - 200 400 500 28.8 12. The optional LCD interface is shown.3 9.4 17  RB2-1-S-065A-12C 65 20 25 50 60 15 10 8.) Weight Model Number A (lbs.3 51  RB2-1-S-302A-15C 302 100 125 250 300 23. / 115% Continuous Rated Horsepower Dimensions (in.Standard Low Voltage Starter Products Open Chassis Solid State Starters rb2 series with mx2 Technology standard duty / 200–600 volt 350% for 30 Sec.9 43  RB2-1-S-156A-14C 156 50 60 125 150 21.9 18 11.8 18 11.9 18 11. • Unit includes standard board-mounted LED interface.5 10.5 160 • Unit requires separate 120 V control power.13 .5 10 20 25 14 10 6.5 10.9 14  RB2-1-S-052A-12C 52 15 20 40 50 14 10 8.5 14.9 13.4 14 9 43  RB2-1-S-180A-14C 180 60 75 150 200 21.BenshawExpress.5 10.1 12.) 208 V 240 V 480 V 575 V H W D  RB2-1-S-027A-11C 27 7.4 17  RB2-1-S-077A-13C 77 25 30 60 75 15 10 8.3 51  RB2-1-S-361A-16C 361 125 150 300 400 23.9 159  RB2-1-S-838A-20C 838 300 350 700 800 29.4 18  RB2-1-S-125A-14C 125 40 50 100 125 21.1 155  RB2-1-S-590A-18C 590 - 250 500 600 28.com 4 .7 18.3 9 43  RB2-1-S-240A-15C 240 75 100 200 250 23. The keypad is shipped loose.1 155  RB2-1-S-515A-17C 515 200 - 450 - 28.9 18 11.1 26.3 8.2 56  RB2-1-S-414A-17C 414 150 - 350 - 27.4 14 9 43  RB2-1-S-180A-15C 180 60 75 150 200 21.8 12.7 12.1 159  RB2-1-S-720A-19C 720 250 300 600 700 30.9 14  RB2-1-S-040A-11C 40 10 15 30 40 14 10 6.4 17  RB2-1-S-096A-13C 96 30 40 75 100 15 10 8. 3 9.9 151  RB3-1-S-590A-18C 551 200 200 450 500 28.5 12. • Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.7 160 • Unit requires separate 120 V control power.9 159  RB3-1-S-720A-19C 623 - 250 500 600 30. KPMX3CBL2M.) Weight Model Number A (lbs.9 18 11.3 9. / 125% Continuous Rated Horsepower Dimensions (in.9 18 11.14 .) 208 V 240 V 480 V 575 V H W D  RB3-1-S-027A-11C 24 7. The keypad is shipped loose.2 18  RB3-1-S-125A-14C 125 40 50 100 125 21.7 18 11. with chassis.  Web stocked Catalog Number Description KPMX3CBL2M NEMA 12/3R Remote Keypad w/ 2 Meter cable A340D Chassis Mounted Display MX2 To order: call 412-968-0100 4 .9 13.4 10 56  RB3-1-S-414A-17C 372 125 150 300 400 27.5 10 20 25 14 10 7.7 14  RB3-1-S-040A-11C 40 10 15 30 40 14 10 8. Please order part number.7 43  RB3-1-S-180A-15C 204 60 75 150 200 21.2 17  RB3-1-S-096A-13C 96 30 40 75 100 15 10 9.Standard Low Voltage Starter Products Open Chassis Solid State Starters rb3 series with mx3 Technology standard duty / 200–600 volt 500% for 30 Sec.5 14.4 14  RB3-1-S-052A-12C 52 15 20 40 50 14 10 9.8 43  RB3-1-S-361A-16C 252 75 100 200 250 23. 4 17  RB2-1-S-096A-13C 96 30 40 75 100 15 10 8.) 208 V 240 V 480 V 575 V H W D  RB2-1-S-027A-11C 24 7.BenshawExpress.9 160 • Unit requires separate 120 V control power. / 125% Continuous Rated Horsepower Dimensions (in.3 9 43  RB2-1-S-361A-16C 252 75 100 200 250 23.) Weight Model Number A (lbs.9 18 11.3 8.com 4 . • Unit includes standard board-mounted LED interface.1 151  RB2-1-S-590A-18C 551 200 200 450 500 28.8 18 11.9 43  RB2-1-S-180A-15C 204 60 75 150 200 21.5 14. The optional LCD interface is shown.5 10.9 14  RB2-1-S-052A-12C 52 15 20 40 50 14 10 8.  Web stocked Catalog Number Description KPMX3CBL2M NEMA 12/3R Remote Keypad w/ 2 Meter cable A340D Chassis Mounted Display MX2 To order WEB STOCKED items: visit www.7 12.9 14  RB2-1-S-040A-11C 40 10 15 30 40 14 10 6.4 18  RB2-1-S-156A-14C 125 40 50 100 125 21.5 10 20 25 14 10 6.9 13.7 18.2 56  RB2-1-S-414A-17C 372 125 150 300 400 27. The keypad is shipped loose.3 9.15 .Standard Low Voltage Starter Products Open Chassis Solid State Starters rb2 series with mx2 Technology standard duty / 200–600 volt 500% for 30 Sec.1 159  RB2-1-S-720A-19C 623 - 250 500 600 30. diagnostics and communications. UL certified and listed • Selector switch for selecting solid state or full voltage operation mounted inside enclosure • Full HP rated bypass contactor with a 1. UL certified and listed • 1800 PIV rated SCRs. soft stop and motor protection capabilities • RS485 ModBus communications • Analog I/O • Available with MX3 technology To order: call 412-968-0100 4 . redundant. with normally open auxiliary contact • Separately mounted “SPE” series overload relay wired for full voltage start and run operation Highlights: • 110 volt control power transformer with primary and secondary fuses RX2E starters provide solid state reduced voltage starting for normal operation and full voltage emergency backup starting with complete • Door mounted start and stop push-buttons electronic motor protection at the flip of a switch. UL certified and listed • 125% continuous duty rated solid state starter. connections • Auxiliary relay with (2) Form C run contacts • Benshaw MX2 programmable motor controller with soft start. but are available with MX3 bypass control board with customer technology. • Door mounted overload reset • Benshaw soft start and emergency Units are stocked with MX2 technology. combination/ circuit breaker • Shunt trip on main circuit breaker • 500% – 30 seconds rated solid state starter. wired for normal bypass operation and full voltage start and run operation. motor protection.Standard Low Voltage Starter Products Prepackaged Starters with ATL Bypass rx series with mx3 or mx2 Technology severe duty 480 v / NEMA 12 or 3r / COMBINATION / REDUNDANT Standard Features: • NEMA 12.16 . metering.15 service factor. Benshaw’s MX solid state controls provide precise digital • Door mounted local-off remote switch starting and stopping. This unique redun- • Door mounted keypad dant design is the ideal solution for critical applications where down- time is extremely disruptive to production operations and cannot be • Door mounted run indicating light tolerated.  Web stocked To order WEB STOCKED items: visit www.) NEMA12 NEMA 3R * 480 V Trip H W D  RX3E-050-480-12KP  RX3E-050-480-3RKP 65 50 100 26 24 12 215  RX3E-075-480-12KP  RX3E-075-480-3RKP 96 75 225 26 24 12 220  RX3E-100-480-12KP  RX3E-100-480-3RKP 124 100 225 48 24 12 230  RX3E-125-480-12KP  RX3E-125-480-3RKP 156 125 225 48 24 12 320  RX3E-150-480-12KP  RX3E-150-480-3RKP 180 150 300 48 24 12 325  RX3E-200-480-12KP  RX3E-200-480-3RKP 240 200 400 48 36 16 335  RX3E-250-480-12KP  RX3E-250-480-3RKP 302 250 400 70 30 18 510  RX3E-300-480-12KP  RX3E-300-480-3RKP 361 300 600 70 30 18 515  RX3E-400-480-12KP  RX3E-400-480-3RKP 477 400 800 87 37 20 765  RX3E-500-480-12KP  RX3E-500-480-3RKP 590 500 1200 87 37 20 790  RX3E-600-480-12KP  RX3E-600-480-3RKP 720 600 1200 87 37 20 815 RX2E Series with MX2 Technology HP CB Dimensions (in.com 4 .) Model Number Model Number Weight A (lbs.) Model Number Model Number Weight A (lbs.) NEMA12 NEMA 3R * 480 V Trip H W D  RX2E-050-480-12KP  RX2E-050-480-3RKP 65 50 100 26 24 12 215  RX2E-075-480-12KP  RX2E-075-480-3RKP 96 75 225 26 24 12 220  RX2E-100-480-12KP  RX2E-100-480-3RKP 124 100 225 48 24 12 230  RX2E-125-480-12KP  RX2E-125-480-3RKP 156 125 225 48 24 12 320  RX2E-150-480-12KP  RX2E-150-480-3RKP 180 150 300 48 24 12 325  RX2E-200-480-12KP  RX2E-200-480-3RKP 240 200 400 48 36 16 335  RX2E-250-480-12KP  RX2E-250-480-3RKP 302 250 400 70 30 18 510  RX2E-300-480-12KP  RX2E-300-480-3RKP 361 300 600 70 30 18 515  RX2E-400-480-12KP  RX2E-400-480-3RKP 477 400 800 87 37 20 765  RX2E-500-480-12KP  RX2E-500-480-3RKP 590 500 1200 87 37 20 790 • 50-600 HP units are service entrance rated. * RX2E and RX3E units include door mounted keypad.Standard Low Voltage Starter Products Prepackaged Starters with ATL Bypass rx series with mx3 or mx2 Technology severe duty 480 v / NEMA 12 or 3r / COMBINATION / REDUNDANT RX3E Series with MX3 Technology HP CB Dimensions (in.BenshawExpress. ## Built-to-order: Please allow one week for shipment.17 . Select a voltage 4. Select a circuit breaker (or none) 6. select a unit • Bypass contactor from the following price pages. Select an enclosure = 5. Select a starter type: (STOCK • MX2PC modular non-bypass or UNIT SHOWN) • MX2PB modular bypassed + 2. Select your options To order: call 412-968-0100 4 . • NEMA 4 or 12 enclosure then add an alpha board and/or • Modular operator station other options as needed from • 480 V the Options section. We will ship stock units • Rotary disconnect operator ship the same day. simply • Non-combination select a unit from the following • Combination circuit breaker pages. We will • Standard 120 V control power modify the stock unit for next transformer day shipment.Standard Low Voltage Starter Products Prepackaged Starters mx2pc / mx2pb series with mx2 Technology non-bypass / continuous duty or integral bypass Configure the MX2PB / MX2PC MX2PB / MX2PC to configurable solid state fit your application starters stocked as: To choose a stock starter.18 . Select a horsepower rating 3. • Service entrance rated with circuit breaker 1. • Non-bypass To modify a starter. BenshawExpress.com 4 .Standard Low Voltage Starter Products Prepackaged Starters mx2pb / mx2pc series with mx2 Technology part number assembler mx2pb 150 4 4 CB ST Starter Series Enclosure MX2PC = Modular Non-Bypassed 4 = NEMA 4/12 MX2PB = Modular Bypassed Disconnect Standard Duty HP Rating NC = None 020 = 20 HP CB = Circuit Breaker 030 = 30 HP 040 = 40 HP Options 050 = 50 HP ST = Standard 075 = 75 HP OP = Options Included 100 = 100 HP 150 = 150 HP 200 = 200 HP 300 = 300 HP 400 = 400 HP Voltage 4 = 480 V 2 = 240 V • All units include 120 V control power transformer To order WEB STOCKED items: visit www.19 . 480 V Dimensions (in. ST = No options / OP = Options included ## Built-to-order: Available for next day shipment. ST = No options / OP = Options included • Available for next day shipment. To order: call 412-968-0100 4 .) H W D MX2PC-010-2-4-NC-** 27 10 240 24 16 15 110 MX2PC-015-2-4-NC-** 40 15 240 24 16 15 110 MX2PC-020-2-4-NC-** 52 20 240 24 16 15 110 MX2PC-025-2-4-NC-** 65 25 240 24 16 15 110 MX2PC-030-2-4-NC-** 77 30 240 24 16 15 110 MX2PC-040-2-4-NC-** 96 40 240 30 16 16 140 MX2PC-050-2-4-NC-** 124 50 240 30 16 16 140 ** Insert option code.) Weight Model Number A HP V (lbs.Standard Low Voltage Starter Products Prepackaged Starters mx2pc series with mx2 Technology non-bypass / continuous duty non-combination 240 V Dimensions (in.20 .) H W D  MX2PC-020-4-4-NC-** 27 20 480 24 16 15 110  MX2PC-030-4-4-NC-** 40 30 480 24 16 15 110  MX2PC-040-4-4-NC-** 52 40 480 24 16 15 110  MX2PC-050-4-4-NC-** 65 50 480 24 16 15 110  MX2PC-060-4-4-NC-** 77 60 480 24 16 15 110  MX2PC-075-4-4-NC-** 96 75 480 30 16 16 140  MX2PC-100-4-4-NC-** 124 100 480 30 16 16 140 ** Insert option code. See page 4-23 for a list of available options.) Weight Model Number A HP V (lbs. See page 4-23 for a list of available options. com 4 .21 .25 S.) HP HP H W D  MX2PB-030-4-4-NC-**2 30 30 480 24 16 15 110  MX2PB-050-4-4-NC-**2 50 40 480 24 16 15 110  MX2PB-075-4-4-NC-**2 75 75 480 36 16 15 150  MX2PB-100-4-4-NC-**2 100 – 480 36 20 15 150  MX2PB-150-4-4-NC-**2 150 150 480 48 20 15 180  MX2PB-200-4-4-NC-**2 200 – 480 48 20 15 180  MX2PB-300-4-4-NC-**2 300 200 480 48 20 15 180  MX2PB-400-4-4-NC-**2 400 300 480 78 30 20 350 ** Insert option code.F.) HP HP H W D  MX2PB-015-2-4-NC-** 15 15 240 24 16 15 110  MX2PB-020-2-4-NC-** 20/25 20 240 24 16 15 110  MX2PB-030-2-4-NC-** 30/40 30/40 240 36 16 15 150  MX2PB-050-2-4-NC-** 50 50 240 36 20 15 150  MX2PB-075-2-4-NC-** 60/75 60/75 240 48 20 15 180  MX2PB-100-2-4-NC-** 100 – 240 48 20 15 180  MX2PB-150-2-4-NC-** 150 100 240 48 20 15 180  MX2PB-200-2-4-NC-** 200 150 240 78 30 20 350 ** Insert option code. 1.BenshawExpress. Heavy Dimensions (in. • Available for next day shipment.15 S. 2 Heavy duty = 500% current for 30 seconds. See page 4-23 for a list of available options. 2 Heavy duty = 500% current for 30 seconds.F. 1. 480 V Std.F.25 S. 1. See page 4-23 for a list of available options.Standard Low Voltage Starter Products Prepackaged Starters mx2pb series with mx2 Technology integral bypass non-combination 240 V Std. 1.) Model Number Duty 1 Duty 2 Weight V (lbs.15 S. ## Built-to-order: Available for next day shipment. ST = No options / OP = Options included 1 Standard duty = 350% current for 30 seconds.  Web stocked To order WEB STOCKED items: visit www. or modified for next day shipment.F. Heavy Dimensions (in. ST = No options / OP = Options included 1 Standard duty = 350% current for 30 seconds.) Duty 1 Duty 2 Weight Model Number V (lbs. 22 . 1.) Duty 1 Duty 2 Weight Model Number V (lbs. Heavy Dimensions (in.15 S.) HP HP H W D  MX2PB-020-2-4-CB-** 20/25 20 240 36 16 15 175  MX2PB-030-2-4-CB-** 30/40 30/40 240 42 20 15 200  MX2PB-050-2-4-CB-** 50 – 240 48 24 15 220  MX2PB-075-2-4-CB-** 60/75 60/75 240 48 24 15 220  MX2PB-100-2-4-CB-** 100 – 240 48 24 15 220  MX2PB-150-2-4-CB-** 150 100 240 48 24 15 220  MX2PB-200-2-4-CB-** 200 150 240 78 30 24 400 ** Insert option code. 1. ## Built-to-order: Available for next day shipment. or modified for next day shipment. See page 3-29 for a list of available options.  Web stocked Catalog Number Description KPMX3CBL2M NEMA 12/3R Remote Keypad w/ 2 Meter cable A340D Chassis Mounted Display MX2 To order: call 412-968-0100 4 . 1.F. ST = No options / OP = Options included 1 Standard duty = 350% current for 30 seconds. 480 V Std.Standard Low Voltage Starter Products Prepackaged Starters mx2pb series with mx2 Technology integral bypass combination circuit breaker 240 V Std. • Available for next day shipment.25 S.F.25 S.) Model Number Duty 1 Duty 2 Weight V (lbs. ST = No options / OP = Options included 1 Standard duty = 350% current for 30 seconds. Heavy Dimensions (in.F. 2 Heavy duty = 500% current for 30 seconds. 2 Heavy duty = 500% current for 30 seconds.) HP HP H W D  MX2PB-050-4-4-CB-** 2 50 40 480 36 16 15 175  MX2PB-075-4-4-CB-**2 75 75 480 42 20 15 200  MX2PB-100-4-4-CB-**2 100 – 480 48 24 15 220  MX2PB-150-4-4-CB-**2 150 150 480 48 30 15 220  MX2PB-200-4-4-CB-**2 200 – 480 48 30 15 220  MX2PB-300-4-4-CB-**2 300 200 480 48 30 15 220  MX2PB-400-4-4-CB-**2 400 300 480 78 30 24 400 ** Insert option code.15 S. 1.F. See page 4-23 for a list of available options. com 4 . and reset push-button Option Code Communications Options A343 Profibus A344 Devicenet A345 Ethernet A346 Lon Works A347 IP internet web addressable A254 RS232 connector — Allows user to connect remotely without opening the encl. fault light and reset push-button A023 Fault light A083 Fault light and reset push-button A084 Run light. run light. and run light A087 H-O-A.Standard Low Voltage Starter Products Prepackaged Starters mx2pb / mx2pc series with mx2 Technology options Option Code Door Mounted Display Option A340A MX3/MX2 LCD Display Option Code Space Heater Option A171 Space heater w / thermostat Option Code Control Options (only one code can be selected) A021 Run light A005 Reset push-button A080 Start / stop push-buttons A081 Start / stop push-buttons and run light A082 Start / stop push-buttons.BenshawExpress. start / stop push-buttons.23 . fault light. run light. fault light. and reset push-button A085 H-O-A and start / stop push-buttons A086 H-O-A. door. To order WEB STOCKED items: visit www. start / stop push-buttons.
Copyright © 2024 DOKUMEN.SITE Inc.