Preliminary IssueDXX-2300-2690/3300-3800-90/75-16i/15.5i-M/M-R Model: ATD4516R9 Antenna Specifications General Electrical Properties Frequency range (MHz) 2300 - 2400 2496 - 2690 3300 - 3800 General Polarization +45° , -45° parameters Electrical downtilt (°) 2 - 12 , continuously adjustable Grounding DC Ground Coupling factor between calibration port and each -26 antenna port (dB) Max. amplitude tolerance from calibration port to 0.9 input ports (dB) Calibration and electrical Max. phase tolerance from calibration port to input 7 parameters ports (°) Ports VSWR 1.5 Co-polarization isolation between ports (dB) 20 Cross-polarization isolation between ports (dB) 25 Beamforming Electrical Properties Frequency range (MHz) 2300 - 2400 2496 - 2690 3300 - 3800 Horizontal 3dB beam width (°) 90 80 85 Gain (dBi) 15.2 16 14.5 Single Cross polar ratio (0°) (dB) 18 18 18 column beam Side lobe suppression for first side 15 15 15 lobe above main beam (dB) Front to back ratio (dB) 23 23 23 Horizontal 3dB beam width (°) 65 65 65 Gain (dBi) 16.7 17 16 Radiation 65° Vertical 3dB beam width (°) 6 5.6 5.5 parameters Broadcast Cross polar ratio (0°) (dB) 18 18 18 beam Front to back ratio (dB) 25 25 25 Side lobe suppression for first side 15 15 15 lobe above main beam (dB) 0° direct beam gain (dBi) 20.2 21 20 0° direction beam horizontal 3dB 26 25 26 beam width (°) Service beam 0° direction beam cross polar ratio 18 18 18 (0°) (dB) 0° direction beam front to back ratio 28 28 28 (dB) Soft Split Electrical Properties Frequency range (MHz) 2300 - 2400 2496 - 2690 3300 - 3800 Horizontal 3dB beam width (°) 30 27 30 Gain (dBi) 19.7 20.5 19 Radiation parameters Vertical 3dB beam width (°) 6 5.6 5.5 Multi-beam Front to back ratio (dB) 25 25 25 Side lobe suppression for first side 15 15 15 lobe above main beam (dB) Notes: 65° broadcast beams and multi-beams are applicable in different scenarios. Select one of them for network coverage based on site requirements and auxiliary equipment conditions. 1 EN/IEC 60950-22(Safety – Equipment installed outdoor). operational wind speed (km/h) 200 Survival wind speed (km/h) 250 Connector 18 x N Female Connector position Bottom Antenna Information Management Module (AIMM) Specifications RET Properties RET type Integrated RET(SingleRET) RET protocols AISG 2. +65 Frontal: 675 (at 150 km/h) Wind load (N) Lateral: 185 (at 150 km/h) Rear side: 645 (at 150 km/h) Max. 3. P. 4. HUAWEI ‘s standard brackets and accessories must be used for any installation. 12 V) Adjustment time (full range) (s) Typ. Ltd.5i-M/M-R Model: ATD4516R9 Mechanical Properties Antenna dimensions (H x W x D) (mm) 1445 x 469 x 206 Packing dimensions (H x W x D) (mm) 1600 x 530 x 270 Antenna net weight (kg) 32 Mast diameter supported (mm) 50 . FCC. 12 V) Power consumption (W) < 3 (when the motor is working.huawei. Bantian. IC. ETSI EN 301 489. depending on antenna type) One pair of 8-pin AISG connectors compliant with the IEC 60130-9 standard [DC (pin 6&pin 1). EN 55024(Immunity). Huawei Technologies Co. 2 Issue: 2017-04-12 .. REACH. ICES-003 Certification: CE. 2. The antenna working environment must meet the requirements specified in the datasheet. Longgang District. Preliminary Issue DXX-2300-2690/3300-3800-90/75-16i/15. 30 (typically.com/antenna Any previous datasheet issues become invalid. RS485 A/B (pin 5/pin 3)] Two AISG-OOK connectors inside the antenna Lightning protection (kA) 5 (8/20 μs) RAE Properties RAE type Integrated RAE RAE protocols AISG-ES-RAE V2.0 / 3GPP Input voltage range (V) 10 V DC to 30 V DC < 1 (when the motor does not work. such as towers and poles.1. must bear the weight and wind load of antennas. DC Connectors return (pin 7). EN 55032(Emission). Installation tools and procedures must conform to requirements described in the antenna installation guide. Facilities. RoHS. 12 V) < 10 (when the motor is starting up or shutting down.0 Standards: EN/IEC 60950-1(Safety). Shenzhen 518129. RCM..R. FCC part15.115 Radome material Fiberglass Radome colour Light grey Operational temperature (℃) -40 . WEEE NOTE 1.China www. Only qualified personnel are allowed to perform installation.