AKD-S700 Accessories Catalog en-US RevA

March 26, 2018 | Author: tommy | Category: Mains Electricity, Capacitor, Electric Current, Electrical Connector, Cable


Comments



Description

AKD™/S700Accessories Catalog North American Edition Edition: February 2011, North America Part Number: 903-200007-00 Original Document Patents Pending Keep all manuals as a product component during the life span of the product. Pass all manuals to future users and owners of the product. Record of Document Revisions Revision Rev-, 12/2009 Remarks Original version Hardware Revision (HR) Hardware Revision A C Firmware M_01-03-zz-zzz ≥ M_01-03-00-011 WorkBench 1.3.0.zzzzz 1.3.0.zzzzz Remarks Start revision STO certified EnDat is a registered trademark of Dr. Johannes Heidenhain GmbH EtherCAT is a registered trademark of EtherCAT Technology Group HIPERFACE is a registered trademark of Max Stegmann GmbH WINDOWS is a registered trademark of Microsoft Corporation AKD is a registered trademark of Kollmorgen™ Corporation Current patents: US Patent 5,646,496 (used in control card R/D and 1 Vp-p feedback interface) US Patent 5,162,798 (used in control card R/D) US Patent 6,118,241 (used in control card simple dynamic braking) Technical changes which improve the performance of the device may be made without prior notice. Printed in the United States of America This document is the intellectual property of Kollmorgen™. All rights reserved. No part of this work may be reproduced in any form (by photocopying, microfilm or any other method) or stored, processed, copied or distributed by electronic means without the written permission of Kollmorgen™. Kollmorgen™ | February 2011 2 AKD/S700 Accessories Manual | 1  General 1 General 1.1 About this Manual This manual describes accessories for the AKD and S700 drives and contains essential technical data. This manual is only valid in conjunction with the manuals for the AKD drive and applicable motor in your application. The manuals for AKD and S700 drives are included on the CDROM shipped with the drives and on the Kollmorgen website (www.kollmorgen.com). These documents are available in PDF format in multiple languages (system requirements: Windows, internet browser, and Acrobat Reader). In all pdf versions, the table of contents and index entries are active bookmarks. Page/chapter numbers in the text with cross references are active links to the target material. 1.2 Symbols Symbol Meaning Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Indicates situations which, if not avoided, could result in property damage. This is not a safety symbol. This symbol indicates important notes. 1.3 General Safety Instructions l l l This manual is only valid in conjunction with the manuals for the drive and motor in your application. You must read the installation manual for the drive and motor in your application and observe the safety instructions in this manual before beginning mounting/installation work. Improper or incorrect cable assembly, mounting, or wiring can result in damage to property and equipment or personnel injury. The following requirements for specialist personnel apply: Transport: only by personnel with knowledge of handling electrostatically sensitive components. Unpacking: only by electrically qualified personnel. Cable assembly: only by electrically qualified personnel. Installation: only by electrically qualified personnel. Commissioning: only by qualified personnel with extensive knowledge of electrical engineering /drive technology. l l l Observe the specific safety instructions for each product group. The maximum cable lengths that are given must not be exceeded, otherwise the drive and motors may not function properly. Kollmorgen is not liable for faults or damage to the connected equipment caused by cables that have been configured by customers. Kollmorgen™ | February 2011 3 AKD/S700 Accessories Manual | 2  Digital Drive Systems 2 Digital Drive Systems The systems shown are possible scenarios for setting up a digital drive system with relevant components. 2.1 Drive System with AKD-P00306 to 02406 4 Kollmorgen™ | February 2011 2 Drive System with AKD-P00307 to 02407 Kollmorgen™ | February 2011 5 .AKD/S700 Accessories Manual | 2  Digital Drive Systems 2. 3  Drive System with S701 to 724 6 Kollmorgen™ | February 2011 .AKD/S700 Accessories Manual | 2  Digital Drive Systems 2. AKD/S700 Accessories Manual | 2  Digital Drive Systems 2.4 Drive System with S748 to S772 Kollmorgen™ | February 2011 7 . 3. Technical Data Lifting capacity Nominal span Lug width Lug height Weight Number of cycles per year Average load Order code Value 120 kg 292 mm 44. Observe and follow the safety instructions for this item.83 kg 20.7 mm 51 mm 0. without attached units such as gearboxes. The suspenders (number depends on the motor type) are delivered with the motor.1. The suspension unit consists of a beam (suspended off the crane hook) and two double-run chain suspenders. The suspension unit is designed for a maximum motor weight of 120 kg and maximum nominal span of the extreme suspension hooks of 292 mm. The Suspension Unit ZPMZ 120/292 is designed for suspending motors only.1 Suspension Unit for AKM8 motors You must read the instruction manual for the suspension unit ZPMZ 120/292. The motor may be suspended on two or four runs of the chain suspender.AKD/S700 Accessories Manual | 3  Mechanical Tools 3 Mechanical Tools 3. and clutches.1 Safety instructions This manual is only valid in conjunction with the instruction manual for the drive and motor you are using in your application.000 60 % FA00092 8 Kollmorgen™ | February 2011 . The S701-712 drives requires a 70 mm clamp and the S724 requires a 100 mm clamp.2 Mounting clamps for side mounting of S701-712 and S724 You can mount S700 drives to side walls or doors of switchgear cabinets using an additional mounting clamp.AKD/S700 Accessories Manual | 3  Mechanical Tools 3.5 370 102 248 0.14 DE-201403 3.1 Clamp for S701-712.13 kg DE-201402 100 mm clamp 5. Technical Data for Clamps Technical Data Mounting holes Height Width Depth Weight Order code 70 mm clamp 5.5 mm 322 mm 72 mm 248 mm 0. 70mm Kollmorgen™ | February 2011 9 .2. 2 Clamp for S724.2. 100mm 10 Kollmorgen™ | February 2011 .AKD/S700 Accessories Manual | 3  Mechanical Tools 3. 2 X9 Screw Terminal Adapter.1 AKD Control Box. Item Linear Feedback Type ACI-AKD-A Heidenhain ACI-AKD-B Renishaw Kollmorgen™ | February 2011 11 . Hall. AKD-X9ADPT The AKD X9 screw terminal adapter plugs into the X9 port for testing of the X9 port connection. This item is not used with S700 drives. Output. Output. The linear feedback device is customer supplied. and Feedback Accessories 4. and two different adapter models are available for common linear feedback types.3 Linear Motor Adapter Linear motor adapters are used to combine feedback. They have connectors for standard Kollmorgen DDL connections. This item is not used with S700 drives. 4.AKD/S700 Accessories Manual | 4  Input. and Feedback Accessories 4 Input. AKD-CONTROLBOX-A The AKD control box is a test instrument that allows you to control all digital and analog inputs on the drive and to monitor the digital and analog outputs. and thermal sensors. 4. 2 Shield Plates Shield plates can be attached to drives to assist in grounding and routing cabling. This manual is only valid in conjunction with the instruction manuals for the drive and motor you are using in your application.AKD/S700 Accessories Manual | 5  Shielding Accessories 5 Shielding Accessories 5.2.1 AKD-z-zzz06 shield plate This shield plate is not included with AKD-z-zzz06. 5. 12 Kollmorgen™ | February 2011 . 5. but can be ordered separately (Item 153-230000-01).1 Safety instructions l l You must read the instructions manual for the drive/motor you are using in your application and observe the safety instructions they contain before beginning mounting/installation work. AKD/S700 Accessories Manual | 5  Shielding Accessories 5. 5. Kollmorgen™ | February 2011 13 .2 AKD-z-00307. AKD-z-00607.2.3 AKD-z-02407 shield plate This shield plate (Item 153-255000-02) is included for use with the AKD-z-02407 drive.2. and AKD-z-01207 drives. and AKD-z-01207 shield plate This shield plate (Item number 153-254001-00) is included for use with AKD-z-00307. AKD-z-00607. AKD/S700 Accessories Manual | 5  Shielding Accessories 5. Recommend shield clamps: Manufacturer Item OBO (Bettermann) BBS-Schelle Typ 2056 OBO (Bettermann) BBS-Schelle Typ 2056 Tension range 16-22 mm 28-34 mm 14 Kollmorgen™ | February 2011 . The clamps are included with the drive.3 AKD and S701 to S724 Shield Clamps (purchased separately) S701 to 724 and AKD drives feature slots on the front panel for connecting additional shield clamps.4 S748 to S772 Shield Clamps (purchased separately) The shroud supplied with S748 to S772 drives features slots for the connection of additional shield clamps. Recommended shield clamp: Manufacturer Phoenix Contact Item SK14 Tension range 6-13 mm 5. All shield clamps required must fit between the drill holes. Use pincers.5 mm². Strip the external cable sheath to a length of approx. Use either metal spacer bushes or screws with nuts and accessories to maintain a spacing of 50 mm. Mount the busbar with the shield clamps fitted on the assembly plate.5 External Shielding Busbar (purchased separately) In special cases.AKD/S700 Accessories Manual | 5  Shielding Accessories 5. 30 mm. Cut a busbar of the required length from a brass rail (cross-section 10 x 3 mm) and drill holes in it as indicated. Squeeze together the coil spring and the supporting plate and push the busbar through the opening in the holder. Push the shield clamp up and route the cable to it via the busbar. Earth the busbar using a single conductor with a cross-section of at least 2. taking care not to damage the braided shield. Kollmorgen™ | February 2011 15 . The following shield clamp is recommended: Manufacturer Weidmüller Item KLBÜ Tension range 6-13 mm A possible scenario for setting up a busbar for the above shield clamps is described below. the cable shields can be routed to an additional busbar via shield clamps. Risk of injury is present due to the spring force of the coil spring. Make sure good contact exists between the shield clamp and the braided shield. Before starting work on power terminals.AKD/S700 Accessories Manual | 6  Mains Chokes 6 Mains Chokes In special cases.1 Safety instructions l l Power terminals can conduct hazardous voltage up to 10 minutes after the mains voltage has been disconnected. shielded cables are not required. A connection diagram appears in the drive instruction manual. l l l 6. Reduces current ripple in the DC link. Prevents voltage dips in the mains voltage caused by commutation. 6. you should observe the requirements of EN 61800-5-1 (which is fixed installation. >=10 mm² or double protective earth) when carrying out mounting and installation work. if mains voltage is more than 3% asymmetrical. Single conductors can be used for wiring. Due to the high earth leakage currents induced by the system. l Several drives can be connected to one mains choke. an unfavorable combination of mains impedance and DC bus capacitance can result in an unloaded DC bus voltage of up to 800 V. check that the phase-toearth and phase-to-phase voltages have de-energised. The purpose of mains choke is as follows: l l l Prevents overloading of the semiconductors in the event of a rapid current rise during commutation. To reduce EMC. the rated current of the mains choke must be greater than or at least equal to the total current of the connected drives. then the S748/772 drives must be used with a mains choke. which increases the service life of the DC link capacitors. the chokes should be mounted isolated from the cabinet. You must read the instruction manuals for the drive/motor you are using in your application and observe the safety instructions they contain before starting mounting/installation work. Without this choke. This manual is only valid in conjunction with the instruction manuals for the drive and motor you are using in your application.2 Type assignment Drive Mains Choke S748 (with asymmetrical mains >3% only) 2% uk S772 (with asymmetrical mains >3% only) 2% uk S701 to 724 Not required 16 Kollmorgen™ | February 2011 . AKD/S700 Accessories Manual | 6  Mains Chokes 6.5-63-4 Mains choke 3L0. 80 A) (0.4-80-4 Mains choke 3L0. Photo: 3L 0.2-160-4 Mains choke 3L0.37 mH.47 mH.3 Order codes Item Mains choke 3L0.19 mH. 160 A) (0. 63 A) (0. 2-160-4 Kollmorgen™ | February 2011 17 .4 Mains choke 3L Mains choke 3L is shown in the photograph and drawings below. 2-75-2 (0.2-50-2 Mains choke 3L0.20 mH. 75 A) uk 4% 4% 4% 2% Order codes Comments DE-92201 N/A DE-92100 N/A DE-92099 N/A DE-201476 Can be used for S748/772 in case of asymmetric mains 2% DE-201477 Can be used for S748/772 in case of asymmetric mains 6.24 mH. 50A) (0. 2-160-4 Technical Data Inductivity Nominal [mH] Current [A] 3L 0.9 101.5 10 5.24 50 3L 0. 2-160-4 0.19 160 3L 0.37 80 3L 0. 2-75-2 0.5 114. 24-50-2 0. 5-63-4 0.3 88.9 185 170 77 122 220 8x12 35 9.5 163 6.9 18 Kollmorgen™ | February 2011 .47 63 3L 0.AKD/S700 Accessories Manual | 6  Mains Chokes Mains choke 3L 0.65 210 175 85 125 240 8x12 16 12.5 310 10x18 95 27 152.5 291 273 116.20 75 Type uk [%] 4 4 4 2 2 A B C D E F Terminals Weight [mm] [mm] [mm] [mm] [mm] [mm] [mm²] [kg] 185 170 77 122 215 8x12 16 9. 4-80-4 0.5 148. 7. Due to the high earth leakage currents induced by the system. All other drives feature built-in mains filters (see the relevant instruction manual). In order for the mains filters to function properly. ≥10 mm² or double protective earth) when carrying out mounting and installation work.1 Safety instructions l l l You must read the instructions manual for the drive/motor you are using in your application and observe the safety instructions they contain before commencing mounting/installation work. check that the phase-to-earth and phase-to-phase voltages have deenergized. Kollmorgen™ | February 2011 19 . This manual is only valid in conjunction with the instructions manual for the drive and motor you are using in your application Power terminals are capable of conducting hazardous voltage up to 10 minutes after the mains voltage has been disconnected.g. the permissible throughput rating of the mains filters must not be exceeded even on peak loading of the drives with Ipeak. you should observe the requirements of EN 61800-5-1 (e. more precisely.AKD/S700 Accessories Manual | 7  Mains Filters 7 Mains Filters AKD-P00306 to 02406 drives require an external mains filter. (typical maximum single value of the amplifier peak currents) In many cases. you can use the next smallest filter in the event of a low coincidence factor g or low load. A connection diagram appears in the drive installation manual. Before starting work on power terminals. Maximum available throughput rating of the mains filter (F): Maximum power consumption of the drive: Maximum power consumption of the motors (M): The rated current INF of the mains filter in a system with i axes must be: (total of twice the rated currents of the amplifiers) and. fixed installation. 480 V AC. UL * No EC directive matches mains filters. UL Mains Filter .single phase. because they are manufactured according to harmonized standards concerning creeping and voltage distances. 230 V AC.AKD/S700 Accessories Manual | 7  Mains Filters 7. UL Mains Filter .three phases.3 Order codes Drive AKD-x-00306 AKD-x-00606 AKD-x-01206 AKD-x-00306 AKD-x-00606 AKD-x-01206 AKD-x-02406 Schaffner Filter FN2320Y-10-06 FN2320Y-10-06 FN2070-12-06 FN3258-7-45 FN3258-16-45 FN3258-16-45 FN3258-30-47 Description Mains Filter . 230 V AC. 480 V AC. CE*. UL Mains Filter . UL Mains Filter . You can use these filters in Europe. 480 V AC. 230 V AC. CE*. CE*. CE*.three phases. CE*. 20 Kollmorgen™ | February 2011 .single phase. 480 V AC.single phase. UL Mains Filter .three phases. CE*. UL Mains Filter . CE*.2 Type assignment Drive AKD-P00306 to 02406 (120 to 240V) AKD-P00307 to 02407 (240 to 480V) S700 Mains filter FN-type Shaffner filters recommended Not required Not required 7.three phases. 29 Fast-on 156 57.3 54 75 5.AKD/S700 Accessories Manual | 7  Mains Filters 7.4 130.3 6.5 45.5 143 5. For single-phase operation only.73 Fast-on * at 40°C environment temperature Kollmorgen™ | February 2011 21 . Technical Data Type Nominal Current [A]* FN2320Y-10-06 10 FN2070-12-06 12 A B C D F M N P Weight Connection [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm [kg] 85 49 40.3 6 156 0.3 87 0.4 Mains filters 1NF-10 and 12 Observe the safety instructions. 7 to M5.8 Nm 2. For three-phase operation only.5 180 FN3258-16-45 16 A 250 45 70 220 235 25 5. 0.9 to 2.4 260 Type Weight Terminals PE Bolt [kg] 0. FN3258-16-45. Technical Data Nominal A B C D F G M P Current* [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] FN3258-7-45 7 A 190 40 70 160 180 20 4.5 Mains filters FN3258-7-45. and FN3258-30-47 Observe the safety instructions.4 240 FN3258-30-47 30 A 270 50 85 240 255 30 5.2 10 mm².8 1. 1. 0.AKD/S700 Accessories Manual | 7  Mains Filters 7.5 4 mm².2 Nm * at 50°C environment temperature 22 Kollmorgen™ | February 2011 .2Nm 0. in case of ambient temperature higher than 40°C. provide the requisite conditions for unobstructed convection for cooling. The connection terminals must never be in the divertion area of hot air. Regen resistor requirements for Kollmorgen servo systems can be calculated using the Motioneering sizing and selection tool available here: http://www.php. Danger of burn. Different resistance values must be used depending on the drive.com/website/com/eng/support/design_tools/motioneering. Mount only in switchgear cabinets. All regen resistors meet the requirements of CE directives and are UL-registered.kollmorgen. The regen resistor is switched on by the brake circuit. power must be reduced by 4% per 10K temperature rise.AKD/S700 Accessories Manual | 8  Regeneration Resistors 8 Regeneration Resistors During braking with the aid of the motor. This energy is dissipated as heat in the regeneration (or "regen" or "brake") resistor. In case of insufficient cooling or false mounting the resistor or the surrounding devices could be overheated or damaged. observe installation clearances. This manual is only valid in conjunction with the instruction manuals for the drive and motor you are using in your application. For best results. 8. Kollmorgen™ | February 2011 23 . the following conditions must be provided for regen resistors: l l l Unobstructed cooling air Unobstructed diversion of warmed air Rated data with maximum ambient temperature 40°C. Observe allowed mounting positions (see dimension drawings). energy is fed back into the drive. use temperature-resistant components in the vicinity of the resistor.1 Safety Instructions l l l l l l You must read the instruction manuals for the drive and motor that you are using in your application and observe the safety instructions they contain before starting mounting/installation work. As Regen resistors can heat up to temperatures in excess of 250°C. A connection diagram appears in the drive's instructions manual. 2 Type assignment Drive AKD-P00306 AKD-P00606 AKD-P01206 AKD-P02406 AKD-P00307 AKD-P00607 AKD-P01207 AKD-P02407 S701 to 712 S724 S748 S772 Regen resistor BAFP(U)/BAR(U)/BAS(U) BAFP(U)/BAR(U)/BAS(U) BAFP(U)/BAR(U)/BAS(U) BAR(U)/BAS(U) BAR(U)/BAS(U) BAR(U)/BAS(U) BAR(U)/BAS(U) BAR(U)/BAS(U) BAR(U) BAR(U)/BAS(U) BAS(U) BAS(U) Resistance/Ohm 33 33 33 15 33 33 33 23 33 23 15 10 8. 15 2000 3200 S748 15 3000 4800 15 6000 9600 23 600 960 23 1000 1600 AKD-P02407.AKD/S700 Accessories Manual | 8  Regeneration Resistors 8. 33 200 320 S701 to 712 33 250 400 33 500 800 33 1500 2400 33 3000 4800 Drive Order code Regen resistor BAS(U) 2000-10 Regen resistor BAS(U) 3000-10 Regen resistor BAS(U) 6000-10 Regen resistor BAR(U) 500-15 Regen resistor BAR(U) 1000-15 Regen resistor BAS(U) 2000-15 Regen resistor BAS(U) 3000-15 Regen resistor BAS(U) 6000-15 Regen resistor BAR(U) 600-23 Regen resistor BAR(U) 1000-23 Regen resistor BAS(U) 2000-23 Regen resistor BAS(U) 3000-23 Regen resistor BAS(U) 4000-23 Regen resistor BAFP(U) 100-33 Regen resistor BAFP(U) 200-33 Regen resistor BAR(U) 250-33 Regen resistor BAR(U) 500-33 Regen resistor BAR(U) 1500-33 Regen resistor BAS(U) 3000-33 BAS-2000-10 BAS-3000-10 BAS-6000-10 BAR-500-15 BAR-1000-15 BAS-2000-15 BAS-3000-15 BAS-6000-15 BAR-600-23 BAR-1000-23 BAS-2000-23 BAS-3000-23 BAS-4000-23 BAFP-100-33 BAFP-200-33 BAR-250-33 BAR-500-33 BAR-1500-33 BAS-3000-33 24 Kollmorgen™ | February 2011 . 23 2000 3200 S724 23 3000 4800 23 4000 6400 33 100 160 AKD-P003 to 12.3 Order codes Description Resistance Rated Max. [ ] Power Power [W] [W] 10 2000 3200 S772 10 3000 4800 10 6000 9600 15 500 800 15 1000 1600 AKD-P02406. Kollmorgen™ | February 2011 25 .4 External regen resistor BAFP(U) Protection class: IP40 l l l Surface temperature can exceed 250°C.AKD/S700 Accessories Manual | 8  Regeneration Resistors 8. Make sure that the necessary space is kept clear. Do not mount on combustible surfaces. AKD/S700 Accessories Manual | 8  Regeneration Resistors 8.5 External regen resistor BAR(U) Protection class: IP20 l l l Surface temperature can exceed 250°C. 26 Kollmorgen™ | February 2011 . Do not mount on combustible surfaces. Make sure that the necessary space is kept clear. Make sure that the necessary space is kept clear. Kollmorgen™ | February 2011 27 .6 External regen resistor BAS(U) Protection class: IP20 l l l Surface temperature can exceed 250°C.AKD/S700 Accessories Manual | 8  Regeneration Resistors 8. Do not mount on combustible surfaces. The digital drives’ high switching frequencies and steep switching edges give rise to the transfer of capacitive currents to the shield by the three phases (U.1 Shielded motor cables For electromagnetic compatibility. To reduce current alternation noise in the motor. V. Why use motor chokes? l l l To compensate for high capacitive charge/discharge currents typical of shielded motor cables approximately 25 m and longer.AKD/S700 Accessories Manual | 9  Motor Chokes 9 Motor Chokes 9. the motor must be supplied with power using a shielded cable.0 mm²) and therefore a higher equivalent resistance are able to reduce the oscillation tendency of the LCR oscillating circuit (amplifier/choke/ cable/motor). This effect is evident in particular on systems with multiple amplifiers operating in parallel on the same mains filter. However. thereby reducing the current transferred to the shield. The structure of a cable with 100% shielding and the capacity equivalent circuit diagram (to earth) are shown below. the current loading of the cable must always be within the limits specified by EN 60204. on large systems. W). Depending on the cable length and cable capacity (determined by design). These shield currents place a load on the drives and motor and. 28 Kollmorgen™ | February 2011 . lead to shifts in potential which can damage other components. This cross-section can also be advantageous for cable lengths shorter than 50 m if the cable capacity and motor inductance are very high. To reduce current ripple in the motor. this can lead to the generation of shield currents with peak values of up to 20 A. The motor chokes slow down the rate of rise of the motor current (reduce edge steepness). Why is the cross-section of the motor cable important? Motor cables longer than 50 m with a small cross-section (such as 4 x 1. These currents flow from the shield to earth. you should make sure that the choke is mounted a sufficient distance away from neighboring components. etc. When laying the motor cable.3 Type assignment Drive* AKD-P003x to AKD-P006x AKD-P012x AKD-P024x S701 to 724 S748/772 Motor choke 3YLN-06 3YLN-14 3YLN-24 3YLN-xx Approvals CE. Kollmorgen™ | February 2011 29 . Provide the requisite conditions for unobstructed convection to cool the choke. The choke can become hot during operation (rising to temperatures in excess of 80°C). you must read and observe the instruction manuals and the safety instructions that they contain for the drive and motor that you are using in your application. UL Not required Condition Motor cable > 25m Motor cable > 25m Motor cable > 25m Motor cable > 25m *AKD part numbers indicate continuous current rating (-003 is 3 A. Mount the motor choke on a conductive earthed assembly plate in the switchgear cabinet. 9.). UL CE.AKD/S700 Accessories Manual | 9  Motor Chokes 9. then the motor choke is wired into the cable close to the amplifier. UL CE. This manual is only valid in conjunction with the instruction manuals for the drive and motor you are using in your application. -012 is 12 A. Therefore. If the motor cable is longer than 25m. allow about 400 mm for the connection to the choke. A connection diagram appears in the drive instructions manual.2 Safety Instructions l l l l l l l Before starting mounting/installation work. UL CE. 4 Motor choke 3YLN-xx Technical Data Rated Data Symbol Units 3YLN-06 3YLN-14 3YLN-20 3YLN-24 Rated current I0rms A 6 14 20 24 Rated voltage Unom V 480 Rated frequency fnom Hz 0 to 150 Max. frequency fmax kHz 8 Inductivity L µH 900 900 450 450 Power loss P W 12 19.5 Wiring cross section max.AKD/S700 Accessories Manual | 9  Motor Chokes 9.4 22.5 10 10 10 Cable diameter (Shield clamp) mm 4 to 13. (Terminals) mm² 10 16 16 16 Width A mm 155 190 190 190 Depth B mm 90 125 125 125 Height C mm 195 230 230 230 Mounting hole distance D mm 130 170 170 170 Mounting hole distance E mm 56.2 Protection class .5 78 78 78 Mounting screws F 4xM6 4xM6 4xM6 4xM6 30 Kollmorgen™ | February 2011 .3 23.IP00 Temperature class F Operation class S1 Weight G kg 4. 8 Feedback Cable Specifications for engineering details on all cables. and current load. depending on the transmission rate: Transmission rate/kbps: Maximum cable length/m: 1000 20 500 70 250 115 10. The values that have been measured can be taken as a guide.15 m P-AKD-CAN-RJ-0-15 0.1 PC connection The drive is connected to the PC or to a switch/hub by a standard net cable with RJ45 connectors .0 m P-AKD-CAN-RJ-3-00 The CANopen bus termination plug is required for bus termination of the last AKD drive connected to the CANopen bus.AKD/S700 Accessories Manual | 10  Cables 10 Cables 10.7 Power Cable Specifications and 10. Value Line Cables Flex Line Cables S700 Cables Kollmorgen™ | February 2011 31 . different shielding concepts depending on rated voltage. due to the varying requirements for minimum code distances. use the CAN RJ12-SubD9.4 Motor and Feedback Cables These cables differ in how they are connected to the drive. The following pre-assembled. Item CANopen bus termination plug CAN RJ12-SubD9 adapter AKD Order Code P-AKD-CAN-TERM P-AKD-CAN-9d-0-15 10. but they should not be interpreted as limits.5 m P-AKD-CAN-RJ-0-50 3. you should use a bus cable with a characteristic impedance of 120 Ω.6 CANopen Bus Cable Specificationsfor specifications. Item CANopen bus cable CANopen bus cable CANopen bus cable Length AKD Order Code 0. The usable cable length depends on the transmission rate.3 CANopen bus cables for AKD and S700 series According to ISO 11898. ready-to-use cables meet the requirements of relevant CE and UL standards. 10. See 10. Cable length.2 CANopen Bus Cables for AKD Configured CANopen bus cables are available for AKD. For connecting an AKD drive to a CANopen device with a SubD9 connector. See 10. 6 CANopen Bus Cable Specifications All cables supplied with AKD and S700 drives are RoHS compliant.2 OD Value Line w/ OD Flex Line OD Flex Line w/ Brake OD (mm) Brake (mm) (mm) (mm 9.2 9.9 CP-508DCAN-XX-X 14.4 VP-508CFAN-XX 10.7 VP-508DFAN-XX 12.3 m 1m 3m Kollmorgen™ | February 2011 .3 VP-508CFAN-XX 10.6 N/A Not Available N/A CP-508EBDN-XX-X 18.5 CP-508DDAN-XX-X 16.7 9.9 CP-507CCAN-XX-X 12.7 mm ± 0.7 CP-507CDAN-XX-X 14.5 11.AKD/S700 Accessories Manual | 10  Cables 10.5 11.7 CP-507CDAN-XX-X 14.7 N/A Flex Line CF-DA0374N-XX-X CF-SB7374N-XX-X CF-RA2574N-XX-X CF-CB7374N-XX-X OD (mm) 7.7 9.3 CP-508EBDN-XX-X 18.1/BiSS.15 m 0.5 10.2 mm Yes 0. HIPERFACE Resolver Incremental/comcoder Value Line VF-DA474N-XX VF-SB4474N-XX VF-RA2474N-XX Not available OD (mm) 6.9 CP-507CCAN-XX-X 12.5 Type Assignment Power Cables Cable Value Line Rating* 3/6 A VP-507BEAN-XX 12 A VP-507BEAN-XX 20 A VP-508DEAN-XX 24A Not Available *Continuous current Feedback Cables Feedback Type SFD EnDat 2.5 11.6.3 10. 10.1 CANopen Cable P-AKD-CAN-RJ-z-zz Cable Specifications Outside diameter RoHS Compliant Length: PAKD-CANRJ-0-15 PAKD-CANRJ-0-30 PAKD-CANRJ-1-00 PAKD-CANRJ-3-00 32 6. AKD/S700 Accessories Manual | 10  Cables 10.2 CANopen Cable P-AKD-CAN-TERM 10.3 CANopen Cable PAKD-CAN-9D-STD-0-15 Kollmorgen™ | February 2011 33 .6.6. 4 CANopen Cable PAKD-CAN-FL-3-00 10.1 AKD 1.6.5 – 6 A Power Cable. VP-507BEAN-xx Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating RoHS Compliant Assembly Weight: VP-507BEAN-01 TPE 9.4 mm ± 0.258 kg 34 Kollmorgen™ | February 2011 .25 mm 94 mm Not rated Not rated 105 C 600 V Yes 0.7.AKD/S700 Accessories Manual | 10  Cables 10. 10.7 Power Cable Specifications All cables supplied with AKD and S700 drives are RoHS compliant. 372 kg 1.536 kg 0.AKD/S700 Accessories Manual | 10  Cables Cable Specifications VP-507BEAN-03 VP-507BEAN-06 VP-507BEAN-09 VP-507BEAN-12 0.955 kg 1.789 kg Kollmorgen™ | February 2011 35 . 521 kg 0.363 kg 1.AKD/S700 Accessories Manual | 10  Cables 10.2 AKD 12 A Power Cable.247 kg 0.942 kg 1.7.784 kg 36 Kollmorgen™ | February 2011 . VP-508CEAN-zz Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating RoHS Compliant Assembly Weight: VP-508CEAN-01 VP-508CEAN-03 VP-508CEAN-06 VP-508CEAN-09 VP-508CEAN-12 TPE 10.5 mm Not rated Not rated 105 C 600 V Yes 0.25 mm ± 0.30 mm 102. 256 kg 0.767 kg 1.068 kg Kollmorgen™ | February 2011 37 .30 mm 109 mm Not rated Not rated 105 C 600 V Yes UL20328 0.3 AKD 12 A Power Cable with Brake.AKD/S700 Accessories Manual | 10  Cables 10.90 mm ± 0.534 kg 2. VP-508CFAN-zz Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating RoHS Compliant AWM Style Assembly Weight: VP-508CFAN-01-0 VP-508CFAN-03-0 VP-508CFAN-06-0 VP-508CFAN-09-0 VP-508CFAN-12-0 TPE 10.7.301 kg 3. 622 kg 3.7.4 AKD 24 A Power Cable with Brake.30 mm 117 mm Not rated Not rated 105 C 600 V Yes 0. VP-508DEAN-zz Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating RoHS Compliant Assembly Weight: VP-508DEAN-01-0 VP-508DEAN-03-0 VP-508DEAN-06-0 VP-508DEAN-09-0 VP-508DEAN-12-0 TPE 11.AKD/S700 Accessories Manual | 10  Cables 10.70 mm ± 0.750 kg 2.496 kg 38 Kollmorgen™ | February 2011 .292 kg 0.874 kg 1. 20 mm 129 mm Not rated Not rated 105 C 600 V Yes UL20328 0.AKD/S700 Accessories Manual | 10  Cables 10.983 kg 1.5 AKD 24 A Power Cable with Brake.328 kg 0. Kollmorgen™ | February 2011 39 . VP-508DFAN-zz Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating RoHS Compliant AWM Style Assembly Weight: VP-508DFAN-01-0 VP-508DFAN-03-0 VP-508DFAN-06-0 VP-508DFAN-09-0 VP-508DFAN-12-0 TPE 12.90 mm ± 0.8 Feedback Cable Specifications All cables supplied with AKD and S700 drives are RoHS compliant.949 kg 3.932 kg 10.7.966 kg 2. 7 mm ± 0.568 kg 0.1 Motor Feedback Cable.211 kg 0.2 mm 67 mm Not rated Not rated 105 C 300 V Yes 0.779 kg 0.357 kg 0. VF-DA0-474N-zz Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating RoHS Compliant Assembly Weight: VF-DA0-474N-01 VF-DA0-474N-03 VF-DA0-474N-06 VF-DA0-474N-09 VF-DA0-474N-12 TPE 6.AKD/S700 Accessories Manual | 10  Cables 10.8.99 kg 40 Kollmorgen™ | February 2011 . 35 mm 96. VF-RA2474N-zz Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating AWM Style RoHS Compliant Assembly Weight: VF-RA2474N-01-0 VF-RA2474N-03-0 VF-RA2474N-06-0 VF-RA2474N-09-0 VF-RA2474N-12-0 TPE 9.5 mm Not rated Not rated 105 C 300 V UL20327 Yes 0.8.551 kg 0.385 kg 1.AKD/S700 Accessories Manual | 10  Cables 10.968 kg 1.273 kg 0.793 kg Kollmorgen™ | February 2011 41 .2 Feedback Resolver Cable.65 mm ± 0. VF-SB4474N-zz Cable Specifications Cable jacket material Outside diameter Bend radius Static flex rating Dynamic flex rating Temperature rating Voltage rating AWM Style RoHS Compliant Assembly Weight: VF-SB4474N-01-0 VF-SB4474N-03-0 VF-SB4474N-06-0 VF-SB4474N-09-0 VF-SB4474N-12-0 TPE 9.3 Sine Encoder Feedback Cable.35 mm 96.269 kg 0.AKD/S700 Accessories Manual | 10  Cables 10.386 kg 1.8.974 kg 1.65 mm ± 0.547 kg 0.798 kg 42 Kollmorgen™ | February 2011 .5 mm Not rated Not rated 105 C 300 V UL20327 Yes 0. Europe Kollmorgen Customer Support Europe Internet E-Mail Tel.: Fax: www.com [email protected] .kollmorgen. please contact us.: Fax: www.kollmorgen.3110 North America Kollmorgen Customer Support North America Internet E-Mail Tel.9394 . In order to serve in the most effective way.4162 Kollmorgen™ | February 2011 43 .9394 .AKD/S700 Accessories Manual | 10  Cables Sales and Service We are committed to quality customer service.639 .0 +49(0)2102 .com [email protected] .com +49(0)2102 . If you are unaware of your local sales representative.540 .com +1 .3545 +1 . please contact your local sales representative for assistance. AKD/S700 Accessories Manual | 10  Cables This page intentionally left blank. 44 Kollmorgen™ | February 2011 .
Copyright © 2024 DOKUMEN.SITE Inc.