AE200 Manual Ver 1.0

May 28, 2018 | Author: rimigari | Category: Calibration, Electronics, Electronic Engineering, Electromagnetic Radiation, Optics


Comments



Description

User ManualAE200-Series Optical Power Meter (AE200A; AE200B; AE220; AE260) Ver. 1.0 . DEVISER shall have no responsibility for any defect or damage caused by improper use. improper maintenance or for any product which has been repaired or altered by anyone other than DEVISER or its authorized representation. The obligation of DEVISER arising from a warranty claim shall be limited to repairing. replacing without charge. This warranty is not transferable and does not apply to the used or demonstration products.Warranty DEVISER warrants that product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. 2012. .. any assembly or component (except batteries and chargers). or at its option. Deviser Part No. Printed in CHINA. © Tianjin Deviser Electronics Instrument Co. Aug. Ltd.: AE200-DL All rights reserved. ......................................................... 4 3 Operating Guide ....................................................................................................... 1 Laser Radiation ....................................Contents 1 Safety ...... 7 5 Powers............................................................................................................. 3 Keypad Descriptions............. 9 6 Specifications .............. 5 4 Special Functions............................... 2 Appearance Display ................................ 3 LCD Display ........................................................................................................................... 1 2 Introductions .............................................................. 1 Power Supply ....... 10 ....................................... LASER RADIATION The AE-Series optical power meter emits laser radiation: 650nm visual laser. Measurement accuracy could be influenced if the optical connector is explored in the air for long time. users should avoid the eye exposure to the open-ended fibers or optical connectors due to the active laser transmitter. When the measurement is taking place. please put the optical connector cap back on.5V AA batteries or rechargeable Ni-MH batteries. When the measurement is complete. 1 . Caution Please install the battery according to the pole indicator within the AE200-Series optical power meter.AE200-Series Optical Power Meter User Manual 1 Safety POWER SUPPLY The AE200-Series optical power meter operates from three 1. The instrument has Visual Fault Location (VFL) module. The wavelengths of AE200-Series optical power meter could be set to 1310 nm,1490 nm,1550 nm or user defined wavelength. and process data on a PC through the TOOLBOX software AE200A/B: AE220A/B: AE260: 2 InGaAs Φ300um PD Detector InGaAs Φ2000um PD Detector InGaAs Φ300um PD Detector Detection range as low as -70dBm . The absolute and reference measurement mode are available.AE200-Series Optical Power Meter User Manual 2 Introductions AE200-Series optical power meter is designed to provide high performance and save cost. The instrument can store up to 500 results. which emit 650nm visible light and fast locate the fault easily. AE200-Series Optical Power Meter User Manual Appearance Display Optical measurement port VFL port USB port Liquid crystal VFL indicator light Button LCD Display Wavelength Power Meter Measured values Automatic shutdown Battery indicator USB indicator 3 . AE200-Series Optical Power Meter User Manual Keypad Descriptions Power on/off , Hold down to control automatic shutdown. press to exit a particular mode Backlight button VFL Power on/off VFL mode: continuous / flashing Storage button Reference measurement mode Wavelength button Selection button 4 . c) Press storage button to browse the data.AE200-Series Optical Power Meter User Manual 3 Operating Guide  Store the measured data AE200 series optical power meter can store up to 500 results. no data it shows "NULL". c) Press storage button Measurement data. to store the d) Press Power on/off button to exit the storage interface. 5 . b) Press selection button to select job id. b) Press selection button to select storage number (job id). a) Press storage button to enter into the storage interface.  Browse the stored data(recall) a) Hold down storage button to enter into the recall interface. d) Press the MODE button to find the next effective stored data automatically. AE200-Series Optical Power Meter User Manual Press the select button to find the next data sequently.  Reference Measurement 6 a) Press REF/dB button to enter into the Reference Measurement Mode and the unit in dB. e) Press the Power on/off button to exit the recall mode. b) Press VFL/ON OFF button to enter into the delete interface. b) Hold down REF/dB button to save the current measurement as the reference value and enter into Reference Measurement Mode. press Power on/off button to cancel the operation. c) Press VFL/ON OFF button again to delete data. press it again to cancel the operation. .  Delete the stored data(recall) a) Enter into the recall interface to browse the data to be deleted. and the automatic shutdown function is canceled.  Operating Steps a) Press the REF / dB button to enter into the calibration mode b) Press the wavelength button to switch the wavelength c) Press selection button to adjust the calibration coefficients.  Self Adjustment Function AE200-Series optical power meter offers self adjustment function for the measurement. the instrument will automatically shut down.0dB ~ -1. 7 . Press the power button.0dB.AE200-Series Optical Power Meter User Manual 4 Special Functions  Automatic shutdown Within 10 minutes without any button operation or the battery is lower than the rating. AutoOff sign disappears. The user could manually adjust the reference values measured from the optical source to the desired value when the measurement contains errors. the adjustment range: +1. press the mode button to clear the calibration coefficients. the wavelength appears calibration mark"*".AE200-Series Optical Power Meter User Manual d) Press the storage button to save the calibration coefficients and exit the calibration mode. Note: After calibrated. 8 . alkaline batteries. turn off the instrument and replaced new battery. rechargeable Ni-MH batteries and Ni-Cd batteries. the battery indicator will remind the user the battery is insufficient. please charge it and continue to use. 9 .AE200-Series Optical Power Meter User Manual 5 Powers AE200-Series optical power meter can be powered by three AA 1.5V ordinary batteries. If use the rechargeable batteries. When the battery is running low. 01 dBm,mW,μW,nW 1310nm、1490nm、1550nm、User-defined FC\SC\ST 1mW、5mW、10mW(Default) Temperature: -10 ~ +60℃ Humidity: < 80 % >30h 185mm×85mm×45mm 320g(Battery is exclusive) .AE200-Series Optical Power Meter User Manual 6 Specifications Mode Accuracy Input Range Resolution Calibrated Wavelength Connectors VFL Power Working Condition Working Time Dimensions Weight 10 AE200A AE200B AE220 AE260 ±0.23dB(±5%) -43dBm ~+26dBm -70dBm~+6dBm 0.17dB (±3%) ±0. com E-Mail: overseasbiz@deviser. 300392 Tel: +86-22-2768 2088 Fax: +86-22-2764 5002 Http://www. Haitai Chuangxin 3rd Road. Ltd.cn 11 .com.8.devisertek. Tianjin. Add: N0. Hi-Tech Industrial Development Area. China.AE200-Series Optical Power Meter User Manual Tianjin Deviser Electronics Instrument Co..
Copyright © 2024 DOKUMEN.SITE Inc.