ADR141

March 24, 2018 | Author: Vishwanath Todurkar | Category: Relay, Scada, Electrical Engineering, Electricity, Electronics


Comments



Description

ASHIDA Numerical OC/EF Protection RelayFeatures: Type: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) • 4 Element (3 Phase + EF) over current IDMT with instant trip. • Back - lit LCD display for settings. • Display of fault current. / Load current. • Selection of Curve: Six selectable curves (Normal Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6). • Separate curve selection for phase and EF. • Design using DSP technology. • Latching of fault current up-to up last 5 fault • Password protection for setting. • Site selectable CT secondary • Relay can be made either IDMT or Define time Programmable operating time in instantaneous element Breaker Fail & Trip Circuit Supervision Function Programmable Annunciation Contact RS 232 (at front) and RS 485 (at r rear side) Communication Port for remote SCADA (only for ADR241A i.e. communicable Relay) Relay). • Communication protocol: Proprietary ASCADA in model AM101xx and IEC standard open protocol IEC60870-5-103 in model AM102xx (only for ADR241A). • • • • General: The ADR141A is member of Ashida Numerical Relay family (Aditya Series) design to meet demand of low and medium switchgear control. The ADR141A is a 3 OC and 1 EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring. The ADR141A continuously monitors all 3 phases and earth current, through CT connections. The high high-speed micro-controller samples this current through a 12-bit A/D converter. The micro micro-controller performs powerful Digital Algorithms to find out Amplitude of current signal, and then this value is use for protection and metering function. All measurement is tuned to fundamental frequency. Each input current is also also displayed on 16 x 2 LCD display for metering. The Relay is having main three functions 1) Protection 2) Self Self-Supervision Supervision 3) Measurement The Relay can be supplied with different model. It can be either Definite Time or IDMT. Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary slightly from that indicated above. ASHIDA ELECTRONICS PVT LTD. Plot No. A-308, Road No. 21, Wagle Industrial Estate, Thane (W)-400 604. INDIA. E-mail: [email protected] Web: www.ashidaelectronics.com Ref.: ADR141A_AM10101 Issue: 05 28.06.10 The ADR141A provide separate programmable ALARM contact for such application.3000% for phase and 50% .2. INDIA.3sec at 10 times). IEP Protection Functions Instantaneous Over current Protection (OC-Inst. Following is summery of different protection functions provided by relay. 21. of extra contacts can be provided.51 50N. The unit has got selection of IDMT characteristic of international IEC standard Very inverse / Extremely Inverse / Long Inverse and Standard inverse (both 3. The ADR141A give all the advantage of numerical relay at affordable cost. All the settings are password protected to prevent unauthorised change.) Instantaneous Earth Fault Protection (EF-Inst. If anyone current is above instantaneous setting the relay provides immediate trip command bypassing IDMT delay. This added extra wiring and extra hardware. Usually separate electromechanical relay used for contact multiplication of protection relay contacts.com Ref.: ADR141A_AM10101 Issue: 05 28. Road No. IEC I >> IE>> I>t. The unit also has Time Multiplier Setting (TMS) from x0.51N 1. Maximum 4 nos.) Time Over current Protection (Phase) (OC-IDMT.) Over current / EF protection: The ADR141A has 4 sensing element 3 OC and 1 EF. 1. These contacts can be programmed as follows Note: Due to our policy to upgrade our products constantly. The instantaneous tripping function is having range of 50% .0 sec and 1. The high speeds CPU continuously monitor the all four current inputs and compare with IDMT as well as instantaneous setting. we reserve the right to supply products which may vary slightly from that indicated above. Ip IE>t.Type: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) 1. Wagle Industrial Estate. E-mail: sales@ashidaelectronics. CPU calculate IDMT delay as per selected IDMT characteristic multiply it with TMS setting and provide trip command if fault is persist even after this time delay.1.) Time Over current Protection (Earth) (EF-IDMT.ashidaelectronics. Protection Functions: The ADR141A give maximum benefit/cost ratio.10 .3000% for EF and can be set in steps of 50%.0 for IDMT delay multiplication. If is input current is less than instantaneous setting but more than IDMT setting. A-308.01 to x1. The tripping current can be set from 10% to 250% for phase and 10% to 250% for Earth fault in steps of 1% by Keys switch provided on front panel. Thane (W)-400 604.06.com Web: www. Plot No. Extra Alarm Contact: Any Protection panel required extra contacts for provide visual ALARM and ANNUNCIATION indication for operator. ASHIDA ELECTRONICS PVT LTD. ANSI 50 50N 50. Also some status contacts for SCADA or remote indications. Status : Status input S1 and S2 are general purpose for SCADA application and S3 and S4 are dedicated for CB NC and NO used for trip circuit supervision. 21. During the fault condition the relay measure the fault current and store in non-volatile memory.Type: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) ANN. PHASE EF The continuously keeping track on its internal hardware and the movement it detect any failure of any component. it give message on LCD display. Via keyboard the display can be program to show the actual current flowing through the relay. A-308. E-mail: sales@ashidaelectronics. ASHIDA ELECTRONICS PVT LTD. Wagle Industrial Estate. ALARM PROTH. If current excesses set value the relay gives trip command. This feature is very useful to give pre information to avoid any mall . In such situation it use some default setting and remain in protection mode. After Fault Relay start one internal timer (settable from 0.com Ref.: ADR141A_AM10101 Issue: 05 28. Note: Due to our policy to upgrade our products constantly.10 . The fault current can be read via keyboard on LCD display Last 5 fault values along with tripping counter can be view via key-board. The type of fault is displayed on LCD display. INDIA. TYPE 1 RELAY 1 RELAY 2 RELAY 3 RELAY 4 2. Thane (W)-400 604. Breaker Fail Function (BF or LBB) Normally after tripping current should be come Zero within 100 – 200ms time depend upon type of fault and breaker mechanism. we reserve the right to supply products which may vary slightly from that indicated above. TYPE 2 OC HF OC IDMT EF HF EF IDMT ANN.05s to 0. Measurement Function: In normal condition this display shows all settings. Supervision Function: 2.1 Self-supervision: OC1 OC2 OC3 EF ANN.8 s) If fault is not cleared during this time then relay declare as Breaker fail (LBB function) 5. All settings are save in electrically erasable read only memory and remain.operation. 3. TYPE 3 HF IDMT PHASE EF ANN.com Web: www.06.ashidaelectronics. Plot No. Road No. TYPE 4 COM. 4. 0 .1 5 0 n o n D r a w o ut A u xi l i a r y S u p pl y: 7 7 . / 5 Amp. we reserve the right to supply products which may vary slightly from that indicated above. INDIA. Contacts and 4 Protocol for optically isolated status inputs ( 2nos for TSS ) communication) 02 Relay with site selectable CTs in Draw out cabinet. Road No. while ordering. Wagle Industrial Estate.com Ref.0 T y p e: A D R 1 4 1 A B ac k T e r m i n al L a y o ut : With 4 Programmable extra contacts. It is user responsibility to specify correct model no. 4 extra Ann. O r d er i n g i n f o r m a t i o n : A D R 1 4 1 A A M X X X X X X X - CSA – 150D CSA – 150 3 3 CSA – 150D 3 X X - X E xam pl e AD R 1 4 1 A – A M . 21.com Web: www. Wh il e Or de r in g Sp e c if y t h e f o ll ow i n g I nf or ma t io n f or AD R 141 A R e l a y Definition of Model No of Aditya Series of Relays AM X XX–XX – X – X – XX – X Reserved for Future Use Auxiliary Supply 01 = 18 – 52 V dc 02 = 77 – 250 V dc 03 = 110 VAC 04 = 230 VAC 05 = 60 V dc 06 = 18 . 3 = 1 Amp. Note: Due to our policy to upgrade our products constantly.: ADR141A_AM10101 Issue: 05 28. The option is specified by model no. A-308. 102 ( with 01 Relay with site selectable CTs. E-mail: [email protected] V dc PT Secondary 0 CT Secondary 1 = 1 Amp. Note: communication protocols are only applicable for ADR241A relay models.06. C a b i n et T y p e: C S A.Type: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) Ordering Information: The relay is available with nos. 2 = 5 Amp. Thane (W)-400 604.0 1.3. ASHIDA ELECTRONICS PVT LTD. Plot No.10 . 4 extra Ann. of different option.ashidaelectronics. Selectable CT TSS Logic. Trip circuit supervision ASCADA and breaker fail function.2 5 0 V dc C T s ec : 1/ 5 Amp.2 . Contacts and 4 Protocol for optically isolated status inputs ( 2nos for TSS ) communication) 02 Relay with site selectable CTs in Draw out cabinet. Selectable AM XXX X CSA – 150 X 3 3OC + 1EF Relays 101 ( with 01 Relay with site selectable CTs.1 0 1 . Trip circuit supervision IEC60870-5-103 and breaker fail function. 21. Road No. we reserve the right to supply products which may vary slightly from that indicated above. A-308. ASHIDA ELECTRONICS PVT LTD. – 7500VA with max. VII.: ADR141A_AM10101 Issue: 05 28. INDIA. (Selectable) For phase 10% . or bypass In steps of 50% For EF 50% . Thane (W)-400 604. III. Plot No. Setting : Inst Operating Time Output contacts : Model AM10101xxxxx & AM10201xxxxx For phase 50% . Wagle Industrial Estate.2VA.0Sec in steps of 10ms. 1) 2 NO Trip duty contact for Alarm and Trip 2) 4 NO ANN.ashidaelectronics.9Sec : Inst.com Ref. Specification For Model AM101xx [ 3OC + 1EF relay ] Inputs Protection Relay Setting Range : : Setting : Operating Time Suitable for CT secondary 1.10 . : Make and carry for 3sec.0 Amp or 5.1 times of set current value. 30A & 660VAC/DC : Make and carry for continuous – 1250VA with max.250 % For EF 10% . : Within class 5 As per IS: 3231. : 18 – 52VDC or 77 – 250VDC. I. : Less than 0. : 90% of set value. 5A & 660VAC/DC : Break AC – 1250 VA DC – 100 W resistive 50W inductive.3000% or bypass In steps of 50% Inst = < 30ms and additional adjustable software delay of 00 – 2. VIII.com Web: www.3000%. VI. IX.Type: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) Technical Specifications: Sr.0 Amp. Supply Contact Rating Trip Duty : Within 1.250% Normal Inverse 1 (C1) Normal Inverse 2 (C2) Very Inverse (C3) Extremely Inverse (C4) Long Time Inverse (C5) Definite Tme (C6) 00(Inst) – 99. Note: Due to our policy to upgrade our products constantly. Supply Burden on Aux. Duty contacts ( Programmable) Particulars : Model 2 NO Trip duty contact for Alarm and Trip AM10102xxxxx & AM10202xxxxx II.06. E-mail: sales@ashidaelectronics. ON / Error Operational Indicators (Flags) : Green LED indicates Relay OK : Red LED indicates Problem in relay Hardware. V. IV. No. To be specified while ordering. : Less than 10VA on any supply. Pickup Current Resetting Current Time Accuracy Burden on CTs Aux. : Repetition rate 300ms. Road No.2. 80 to 1000MHz. 50Hz . X. Thermal Withstand Capacity High Voltage Test : x40 times the normal current for 3sec. 20 cycle in 3 orthogonal XIX. Fast transient interference/bursts : IEC 60255-22-3 and IEC 61000-4-2 class III : 10V/m.5kV (RSM) 50Hz : Between Open contact of ALARM – 1kV (RSM) 50Hz XII. Shock Test : IEC 60255-21-2 class 1 : Semi-Sinusoidal : 5g acceleration. ASHIDA ELECTRONICS PVT LTD.: ADR141A_AM10101 Issue: 05 28. OC Fault / EF Fault TRIP / BF : Green LED indicates the relay tripped by OC. XI.5 J. Wagle Industrial Estate. both polarities 150pF. Irradiation with radio frequency field. Note: Due to our policy to upgrade our products constantly. Ri = 50Ω. 3 positive and 3 negative impulse at interval of 5 sec : IEC 60255-22-1.B. 5/50ns. actual trip is not executed. : Red LED indicates BF operated. : x2 Continuous : IEC 60255-5 : Except DC Voltage : Only DC voltage – 2.10 .com Web: www. : Each 3 shocks in both direction of the 3 axes XVIII. 21. is pressed. SR type when BF contact selected as SR and HR type when BF contact selected as HR. E-mail: [email protected]: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) PKP / HF : Green LED indicates relay Pickup. Seismic Test : IEC 60255-21-3 XIII.0 kV (RMS). XVI. 1kHz AM : IEC 60255-22-3 and IEC 61000-4-3. : Red LED indicates relay operated at HF. 80%. Hand Reset (HR) Type : Green LED Indicates that Trip pulse is being executed. SR type when TRIP contact selected as SR and HR type when TRIP contact selected as HR. Thane (W)-400 604. Vibration Test : IEC 60255-21-1 class 1 / IEC 60068-2-6 : Sinusoidal 10 to 60Hz ±0. Hand Reset (HR) Type : Red LED indicates the relay tripped by EF. XVII.8 kV DC : Between Open contact of TRIP / CLOSE 1. 5kHz burst duration = 15ms.5 kV (peak) 1MHz . class III : 4kV. Impulse Voltage Test (all circuit class – III) High Frequency test : IEC60255-5 : 5kV (peak) 1. When BYPASS P. Both polarities. INDIA.035 mm : Amplitude. 0. Ri 330 Ω XV. we reserve the right to supply products which may vary slightly from that indicated above. pulsemodulated. 60 to 150Hz. 0.ashidaelectronics. Class III : 2. τ = 15µs 400 surges / s duration 2 s XIV.com Ref. duration 1 min.06.2 / 50us.5g acceleration : Sweep rate 1 octave/min. 8kV air discharge. A-308. duration 11ms. Plot No. Electro static Discharge : IEC 60255-22-2 Class III and IEC 61000-4-2 class III : 4kV/6kV contact discharge. XXI.8m/s2) acceleration in each of the 3 mutually perpendicular axes : IEC60068-2 Cold – 2 hours operational condition at –(40 +/. A-308.weep (@a sweep rate of 1 octave/minute) vibration in the frequency range (5-40 Hz) at amplitude of 1.5gn (whichever is less) XX.2 hours steady sate damp heat operational condition at temperature at (55 +/.5mm or 0. 21. Vibration Endurance Test : IEC60255-21-1 20-sweeps (@ a sweep rate of 1octave / minutes) vibration in the frequency range (10-150Hz) at 1 gn (9. of axes .06. Shock Response Test : IEC 60255-21-2 Clas-1 : 3 shocks of 1gn peak acceleration and 11ms pulse in each of two opposite direction . Shock Withstand : IEC 60255-21-2 Clas-1 : 3 shocks of 15gn peak acceleration and 11ms pulse in each of two opposite direction . Environmental withstand (cold. Dry heat & steady state Damp Heat) • Datasheet Change Log for ADR141A Note: Due to our policy to upgrade our products constantly. Drawing References : For Cabinet Type : For Operating Characteristics CSA -150 C1 C2 C3 C4 C5 : For Electrical Connection 3OC + 1EF AM10101 .APR05101 . we reserve the right to supply products which may vary slightly from that indicated above.APR01801 .0gn (whichever is less) : In single axis sine sweep in Y-axis . Wagle Industrial Estate. of axis : 3 XXIII.ashidaelectronics. C as per IEC60068-2-2 Steady state damp heat . of axis : 3 XXII. INDIA.APR06804_2 XXIV. Thane (W)-400 604.2) deg. No. C & humidity 95% RH as per IEC60068-2-78 XXV.3) deg C as per IEC600682-1 Dry – 2 Hours dry heat operational condition at(55+/2 2 deg. Plot No.APR05201 .MAC00101 .10 . E-mail: sales@ashidaelectronics. No. 3. Bump Test : IEC 60255-21-2 Class-1 : 1000 bumps of 10gn peak acceleration and 16ms pulse duration in each of the two opposite direction per axis as per IEC60255-21-2 class 1 No.com Web: www. ASHIDA ELECTRONICS PVT LTD.: ADR141A_AM10101 Issue: 05 28. Road No.APR05301 .com Ref.APR02201 .5mm or 1.Type: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) : In single axis sine sweep in X-axis sweep (@a sweep rate of 1 octave/minute) vibration in the frequency range (5-40 Hz) at amplitude of 3. ASHIDA ELECTRONICS PVT LTD. we reserve the right to supply products which may vary slightly from that indicated above. INDIA.09 01.12.11.com Web: www. (Revis ion) 01 02 03 04 Date Description /Changes 28.09 Original Revision Communicable Model ADR241A added Photograph of the relay Modified Settings Changed Note: Due to our policy to upgrade our products constantly. Plot No. Wagle Industrial Estate.09 01. A-308.06.09 09.com Ref. Road No.12.: ADR141A_AM10101 Issue: 05 28. Thane (W)-400 604.Type: ADR141A ADR241A (Communicable) (ADITYA Series) (Preliminary) Issue No.08.ashidaelectronics.10 . 21. E-mail: sales@ashidaelectronics.
Copyright © 2024 DOKUMEN.SITE Inc.